Carbon Dioxide Monitor/Controller With The USB Data Logger

Size: px
Start display at page:

Download "Carbon Dioxide Monitor/Controller With The USB Data Logger"

Transcription

1 Carbon Dioxide Monitor/Controller With The USB Data Logger F000IAQ-CO -1XXU series The monitor/controller is special design to monitor and alarm CO level, also provides one on/off relay output to control a fan or a CO generator. An data logger is designed inside, which can record CO measurements more than 11 days and can be saved the data via a USB disk. The memorial CO monitor/controller not only very easily to be used as a CO monitor and controller, but also as a recorder of the measurements. Application in schools, kindergartens, office buildings, greenhouses and so on. Features Real-time monitoring carbon dioxide (CO ) alternative a ventilator and a CO generator measurements during 0ppm to 0,000ppm range An internal data logger is used to record CO Optional real-time monitoring temperature from -0 to 60 and relative humidity from 0 to measurements as well as optional temperature and RH% measurements. 100%RH With super large capability memorizer, it can save Non-dispersive infrared (NDIR) CO sensor with data of up to 11 days self calibration, 1 years lifetime Provide the software to preset the sampling time, read The -LED indicator lights indicate three CO and record CO/temperature&RH levels on PC measured ranges Post the data from the internal memorizer by any USB LED lights brightness adjustable disk, and copy the data to a PC Easy preset CO level for buzzer alert (optional) Provide 1X On/Off dry contact output to control Specifications Gas detected Carbon Dioxide (CO ) Sensing element CO NDIR life CO range Accuracy@ (77 ) Stability Calibration interval CO setting & Display resolution Pressure Dependence Temperature& RH sensor (optional) Temperature measurement range Non-Depressive Infrared Detector (NDIR) >10 years 0~000ppm 0~0,000ppm or 0~0,000ppm optional ±0ppm + % of reading (0~,000ppm) ±7ppm or 10% of reading whichever is greater (0~0,000ppm or 0~0,000ppm) <% of FS over life of sensor (1 yr typical) ABC Logic Self Calibration Algorithm 1ppm Can be preset the altitude by the end users to eliminate the pressure influence via a inside software Combined digital temperature and relative humidity sensor 0 ~60 ( ~10 ) 1

2 Humidity measurement range 0~100%RH Temperature& RH accuracy Option: 1X dry contact output Operation condition Power supply Consumption Weight Dimensions Connections Interface Installment standard ±0. / ±%RH Rated currency for contact point: A 0VAC/0VDC, resistance load 0 ~60, 0~9%RH (non-condensing) VAC/VDC ±10% wiring connection Or with a power adaptor of V/0V or V/110V.W/ Max,.W/ Average 80g 10mm 90mm 0mm Locate in interface of connection 6mm 6mm or wire box Wiring standard Wire section area<1.mm Approval Standard Presetting and operation Sampling alternation Software Features CE-Approval Buttons and internal DIP switches Preset the sampling alternation during 60s to 1h. The general maximum day of the data record is 11 days Outputs date is in.txt format USBDataGather software is for stand-alone application. It s used to set parameters for different applications, to display the graph of capture data, to calculate the average value of a period, as well as the max. and min. value Buttons/LCD/USB Connection room temperature ventilation device on CO level Insufficient ventilation poor ventilation optimal ventilation turn on/off decrease increase switch setting Power adaptor connection USB connection Create Configuration File

3 View Record Curve

4 View Record Text View Curve Information

5 Model Guide item model 1 F000IAQ-CO-100U F000IAQ-CO-101U Option -TH (for above items) description CO Detector&Monitor with LCD display, LED lights indicates CO levels range. Data logger records CO measurements with a USB disk to move the data to a PC. Power supply: VAC/VDC CO Monitor&Controller with LCD display, LED lights indicates CO levels range. 1X relay On/Off control output. Data logger records CO measurements with a USB disk to move the data to a PC. Temperature and RH monitoring and data recordering option for above items. Wiring Diagram 1 G+ VAC G0 AN ON COM B A F000IAQ-CO-111U/111U 100U RS-8 1 G+ VAC G0 AN ON COM B A F000IAQ-CO-111U/111U 101U RS-8

LBTKG-CO462 TKG-CO2 SERIES. Carbon Dioxide Detector/Controller. Features. Professional Design & Manufacture CO 2 Controllers.

LBTKG-CO462 TKG-CO2 SERIES. Carbon Dioxide Detector/Controller. Features. Professional Design & Manufacture CO 2 Controllers. LBTKG-CO46 TKG-CO SERIES Carbon Dioxide Detector/Controller Professional Design & Manufacture CO Controllers Wall mounted Features Special used to real-time detect CO level in air ducts. NDIR infrared

More information

CDD Carbon Dioxide Transmitter

CDD Carbon Dioxide Transmitter Introduction The OSA CO2 transmitter uses Infrared Technology to monitor CO2 levels within a range of 0 2000 ppm and outputs a linear 4-20 ma or 0-5/0-10 Vdc signal. The enclosure is designed to operate

More information

CDR-RH Room CO 2, Temperature and Humidity Sensors (Controllers)

CDR-RH Room CO 2, Temperature and Humidity Sensors (Controllers) Product sheet SN1.401 Type CDR-RH CDR-RH Room CO 2, Temperature and Humidity Sensors (Controllers) CDR-RH sensors are designed to detect carbon dioxide concentration, relative humidity and temperature

More information

CDD4 Series Room CO2 Transmitter Installation Instructions

CDD4 Series Room CO2 Transmitter Installation Instructions CDD4 Series Room CO2 Transmitter Installation Instructions Introduction The CO2 transmitter uses Infrared Technology to monitor CO2 levels and outputs a linear 4-20 ma or 0-5/0-10 Vdc signal. Options include

More information

CDD4 Duct Carbon Dioxide Transmitter

CDD4 Duct Carbon Dioxide Transmitter Drill or punch a 1-1/8 or 1-1/4 hole in the duct at the preferred location and insert the probe into the hole to mark the enclosure mounting holes. Remove the unit and drill the four mounting holes. Clean

More information

Carbon Dioxide Monitor Instruction Manual

Carbon Dioxide Monitor Instruction Manual Table of Contents Introduction... 1 Before you Start... 1 Carbon Dioxide Monitor Instruction Manual Button Functions... 2 Reading the Display... 3 Using the Monitor... 5 Carbon Dioxide Levels and Guidelines...

More information

Carbon Monoxide (CO) Gas Detection and Control System

Carbon Monoxide (CO) Gas Detection and Control System Carbon Monoxide (CO) Gas Detection and Control System DESCRIPTION Gas monitor with built-in carbon monoxide (CO) sensor, wall-mounted, accepts inputs from remote devices such as other gas sensors, temperature

More information

VAT series controller and transmitter. Manual

VAT series controller and transmitter. Manual VAT series controller and transmitter Manual 1. General describe.. 2. Notice for use.. 1 1 3. Panel & connection introduce.. 2 4. Operate introduce.. 5. Application introduce. 6. Communication. 7. Specification..

More information

Datasheet: K-33 BLG Sensor

Datasheet: K-33 BLG Sensor Datasheet: K-33 BLG Sensor The K- 33 BLG (bio- logger) sensor is designed to measure percentage of carbon dioxide up to 30%, as well as temperature and humidity. This makes it an excellent sensor for enclosed

More information

CDR Room CO 2 and Temperature Sensor with Modbus

CDR Room CO 2 and Temperature Sensor with Modbus Product sheet SN1.404 Type CDR-MOD CDR-MOD Room CO 2 and Temperature Sensors with Modbus The CDR-MOD sensors are designed to detect carbon dioxide concentration and temperature in the room spaces and have

More information

Indoor Air Quality Meter/Datalogger

Indoor Air Quality Meter/Datalogger User Manual Indoor Air Quality Meter/Datalogger Model EA80 CC Additional User Manual Translations available at www.extech.com Introduction Congratulations on your purchase of the Extech EA80 Indoor Air

More information

TOXALERT MODEL AIR 2000

TOXALERT MODEL AIR 2000 TOXALERT MODEL AIR 2000 NOTE: Toxalert s Model GVU-CO 2 Sensor is the same as the Air2000R. Microprocessor-based, Infrared Environmental CO 2 Sensor OPERATOR S MANUAL TOXALERT TM INTERNATIONAL INC. P.O.

More information

User Guide. Indoor Air Quality Meter/Datalogger. Model EA80

User Guide. Indoor Air Quality Meter/Datalogger. Model EA80 User Guide Indoor Air Quality Meter/Datalogger Model EA80 Introduction Congratulations on your purchase of the Extech EA80 Indoor Air Quality Meter. This meter measures Carbon Dioxide (CO 2, ppm) levels,

More information

MOD-RI Room Interface Modules with Modbus

MOD-RI Room Interface Modules with Modbus Product sheet MOD3.00 Type MOD-RI MOD-RI Room Interface Modules with Modbus The MOD-RI are room interface modules designed to provide room control interface for the building management systems. The MOD-RI

More information

Richmond Heights. Smart Wi-Fi Capacitive Touch With Dual Protocols Universal Controller. Go Green

Richmond Heights. Smart Wi-Fi Capacitive Touch With Dual Protocols Universal Controller. Go Green Richmond Heights Smart Wi-Fi Capacitive Touch With Dual Protocols Universal Controller Presentation Agenda 1. Introduction To Richmond Heights 2. Smart Universal Controller Features Of DAS-G01 3. DAS-G01

More information

tsense (Disp) T RH RL

tsense (Disp) T RH RL User Manual tsense (Disp) T RH RL CO 2 -, temperature- and relative humidity transmitter General tsense (Disp) for wall mounting measures indoor air carbon dioxide concentration, temperature and relative

More information

Product Specification. tsense VAV. CO 2 -, Temperature- and RH- sensor in a housing with colour touch display

Product Specification. tsense VAV. CO 2 -, Temperature- and RH- sensor in a housing with colour touch display Product Specification tsense VAV CO 2 -, Temperature- and RH- sensor in a housing with colour touch display General tsense VAV is an advanced and versatile 3-in-1 transmitter designed for installation

More information

MH-Z16 Intelligent Infrared Gas Module

MH-Z16 Intelligent Infrared Gas Module MH-Z16 Intelligent Infrared Gas Module User s Manual (Version: 2.4) Valid from: 2017.05.24 Zhengzhou Winsen Electronics Technology CO., LTD Statement This manual s copyright belongs to Zhengzhou Winsen

More information

Product Specification. CO 2 Engine ICB. Sensor module for bio applications

Product Specification. CO 2 Engine ICB. Sensor module for bio applications Product Specification CO 2 Engine ICB Sensor module for bio applications General CO 2 Engine ICB is targeted on bio applications with required measurement range 0 to up to 30% vol CO 2. This document contains

More information

2F. No.25, Industry E. 9 th Rd., Science-Based Industrial Park, Hsinchu, Taiwan

2F. No.25, Industry E. 9 th Rd., Science-Based Industrial Park, Hsinchu, Taiwan OGM220 Series Dual Channels NDIR CO 2 Gas Sensor Module Introduction OGM220 series is a dual channels NDIR module having a digital output directly proportional to CO 2 concentration. OGM220 is designed

More information

DMT340 Series Dewpoint and Temperature Transmitters for Very Dry Conditions

DMT340 Series Dewpoint and Temperature Transmitters for Very Dry Conditions www.vaisala.com DMT340 Series Dewpoint and Temperature Transmitters for Very Dry Conditions The display shows measurement trends, real-time data, and measurement history. Features/Benefits Measures dew

More information

AQS51/61-KAM COMBINED CO 2 -/TEMPERATURE DUCT SENSOR/CONTROLLER

AQS51/61-KAM COMBINED CO 2 -/TEMPERATURE DUCT SENSOR/CONTROLLER AQS51/61-KAM COMBINED CO 2 -/TEMPERATURE DUCT SENSOR/CONTROLLER SPECIFICATION DATA For this analog output configuration the software program STRATEGY is available, which is part of the User Interface Program

More information

User Manual. PolyGard AT Infrared Carbon Dioxide transmitter Serial No. AT December, PolyGard is a registered trademark of MSR

User Manual. PolyGard AT Infrared Carbon Dioxide transmitter Serial No. AT December, PolyGard is a registered trademark of MSR PolyGard AT82-1160 Infrared Carbon Dioxide transmitter Serial No. AT81-001 User Manual December, 2007 Page 2 1 Intended Use:... 3 2 Function... 3 3 Terminal Connections... 4 4 Calibration... 4 4.1 Calibration

More information

Schneider Electric s SCD series of duct mount sensors measure the levels of CO 2. , RH (if equipped) and temperature of air inside a duct.

Schneider Electric s SCD series of duct mount sensors measure the levels of CO 2. , RH (if equipped) and temperature of air inside a duct. 1 Series Specifications Input age. 24 VAC ±20%, 20 to 36 VDC Class 2 Analog....4-20 /0-5 VDC/0-10 VDC (selectable) Sensor Current Draw... 20-36 VDC 40 avg., 105 max. 24 VAC 50 avg., 150 max. Operating

More information

Output signal active note. Output signal. temperature DC V, DC V DC V, DC V DC V

Output signal active note. Output signal. temperature DC V, DC V DC V, DC V DC V Duct Air Quality Sensor Duct air quality sensor for detection of CO₂ with 0 to10 V output. Optional integrated, humidity, VOC sensors and LCD display. Type Overview Type active CO₂ 22DC-11 22DC-110L 22DCK-11

More information

RoHS. CO 2, Temperature & Humidity Transmitter Applications

RoHS. CO 2, Temperature & Humidity Transmitter Applications NDIR CO 2 Dual sensor Needless calibration on long-term use Can measure over 95% RH condition Applicable to humid storage, mushroom farm and floricultural industry Communication Method RS-485 (Standard)

More information

Sensor for car parks and tunnels

Sensor for car parks and tunnels Page 1 Sep. 2017 system with exchangeable sensor element including digital value processing, temperature compensation and selfmonitoring algorithm for the continuous sensing and control of the ambient

More information

Multi-Point Gas Detection and Control System

Multi-Point Gas Detection and Control System Multi-Point Gas Detection and Control System Specifications subject to change without notice. USA 40804 Page of 7 DESCRIPTION Wall mounted, microprocessor-based, multi-point, analog electronic control

More information

SmartX Living Space Sensors

SmartX Living Space Sensors Specification Sheet SmartX Living Space Sensors schneider-electric.com 1 Product Description SmartX sensors are a family of living space sensors for use with SmartX IP controllers that use the EcoStruxure

More information

TF243 Series Digital Thermostat Fan Coil Unit Control

TF243 Series Digital Thermostat Fan Coil Unit Control TF243 Series Digital Thermostat Fan Coil Unit Control Features SPECIFICATION DATA General The TF243 series digital thermostat is designed for 3-speed fan and modulating valve control in a fan coil system,

More information

AIR QUALITY/ GAS DETECTION

AIR QUALITY/ GAS DETECTION AIR QUALITY/ GAS DETECTION Veris offers an extensive line of CO, and NO 2 sensors. Whether your application requires ventilation of a parking garage or an indoor venue, we have the perfect product for

More information

Viconics VT76x6W Water-source Heat Pump Controllers Engineering Guide Specification

Viconics VT76x6W Water-source Heat Pump Controllers Engineering Guide Specification Viconics VT76x6W Water-source Heat Pump Controllers Engineering Guide Specification General The VT76xxW series is designed for single-stage and multi-stage control of water source heat pumps with dedicated

More information

ALPHACallisto Discrete Inputs

ALPHACallisto Discrete Inputs User Manual ALPHACallisto Discrete Inputs ALPHACallisto Discrete Inputs Page 1 CTENT 1- DI STEP BY STEP... 3 2- INTRODUCTI... 4 2.1- GENERAL SYNOPTIC... 4 2.2- HARDWARE ARCHITECTURE... 5 2.3- DISCRETE

More information

Model CD-AW. Infrared Environmental CO2 Sensor. Operator's manual

Model CD-AW. Infrared Environmental CO2 Sensor. Operator's manual Model CD-AW Infrared Environmental CO2 Sensor Operator's manual Copyright 2011 Date 10/11/11 CD-AW Initial draft 10/20/11 Page: i Table of Contents Preface... 1 Model Identification... 1 Introduction...

More information

K33-BLG/ELG Sensor module for environment logging Data Sheet and Manual

K33-BLG/ELG Sensor module for environment logging Data Sheet and Manual K33-BLG/ELG Sensor module for environment logging Data Sheet and Manual General CO 2Engine -ELG (left) and CO 2Engine -BLG (right) SE-0020 K-33 ELG Sensor CM-0026 K-33 ELG Devkit SE-0027 K-33 BLG Sensor

More information

Please Read Instruction Carefully Before Installation! Figure 1: A/CO2-DUCT

Please Read Instruction Carefully Before Installation! Figure 1: A/CO2-DUCT Installation and Operation Instructions A/CO2-DUCT Series Please Read Instruction Carefully Before Installation! Figure 1: A/CO2-DUCT PRECAUTIONS REMOVE POWER BEFORE WIRING. NEVER CONNECT OR DISCONNECT

More information

one probe, SD card real time data recorder CO2, %RH, Temp., Dew point, Wet bulb CO2 METER + HUMIDITY/Temp. Model : CO2-9914SD

one probe, SD card real time data recorder CO2, %RH, Temp., Dew point, Wet bulb CO2 METER + HUMIDITY/Temp. Model : CO2-9914SD one probe, SD card real time data recorder CO2, %RH, Temp., Dew point, Wet bulb CO2 METER + HUMIDITY/Temp. Model : CO2-9914SD Your purchase of this CO2 METER,+ HUMIDITY/Temp. with SD CARD DATA RECORDER

More information

Resolution 1 F (1 C) single point; degrees C or Calibration single or dual point Calibration F

Resolution 1 F (1 C) single point; degrees C or Calibration single or dual point Calibration F RMS Rainwater Harvesting Series 100 Controller Specifications Measurement Performance Contacting Conductivity ph Range 0-10,000 µs/cm Range -2 to 16 ph units Resolution 1 µs/cm Resolution 0.01 ph units

More information

Multi-Point Gas Detection and Control System

Multi-Point Gas Detection and Control System Multi-Point Gas Detection and Control System DESCRIPTION Wall mounted, microprocessor-based, multi-point, analog electronic control system for various gas, temperature and humidity detection, control and

More information

PS-AULDP Series. Overview. Applications. Features & Benefits. Datasheet. Ultra Low Air Differential Pressure Transmitters

PS-AULDP Series. Overview. Applications. Features & Benefits. Datasheet. Ultra Low Air Differential Pressure Transmitters PS-AULDP Series Datasheet Ultra Low Air Differential Pressure Transmitters Overview The PS-AULDP Series are ultra-low-pressure transmitters. These devices can be used to measure differential pressure between

More information

CO2 1% or 30%, Temperature & %RH, Diffusion Data Loggers

CO2 1% or 30%, Temperature & %RH, Diffusion Data Loggers CO2 1% or 30%, Temperature & %RH, Diffusion Data Loggers Models Covered ESCM 18 ESCM 19 ESCM 209 ESCM 210 ESCM 08-CC ESCM 16 ESCM 17 Save meter information for future reference Model Number: Serial Number:

More information

SMART & NEW! Sensor probe Interchangeable Normal measurement SMART PORTABLE IAQ METER SERIES -3 (SPECIFICATION )

SMART & NEW! Sensor probe Interchangeable Normal measurement SMART PORTABLE IAQ METER SERIES -3 (SPECIFICATION ) SMART PORTABLE IAQ METER SERIES -1 (INTRODUCTION) > High performance two ( 2 ) microprocessors technology Multi-display with Temp. RH% (Option: ambient

More information

Combustion gas and odorous gases within the room (smoke, body odor, timber dope Gas detected

Combustion gas and odorous gases within the room (smoke, body odor, timber dope Gas detected VOC Detector with Relay Model TON-0012 User Manual Specifications Combustion gas and odorous gases within the room (smoke, body odor, timber dope Gas detected and toluene emitted by other building materials),

More information

Trueyes Inc. Carbon Dioxide (CO2) Module

Trueyes Inc. Carbon Dioxide (CO2) Module Trueyes Inc. Carbon Dioxide (CO2) Module A-1408~9, Gwangmyeong Techno Park, 60, Haan-ro, Gwangmeong-si, Gyeonggi-Do, Korea, 14322 TEL : +82-2-2083-2377~8 FAX : +82-2-2083-2379 1 Specifications General

More information

SPECIFICATIONS HAND HELD PARTICLE COUNTER KC Higashimotomachi, Kokubunji, Tokyo , Japan

SPECIFICATIONS HAND HELD PARTICLE COUNTER KC Higashimotomachi, Kokubunji, Tokyo , Japan SPECIFICATIONS HAND HELD PARTICLE COUNTER KC-52 3-20-41 Higashimotomachi, Kokubunji, Tokyo 185-8533, Japan No. 10017-3E 18-04 Printed in Japan Outline The hand held particle counter KC-52 is designed to

More information

CAEL-DP Series Dew Point Transmitter for Industrial Control

CAEL-DP Series Dew Point Transmitter for Industrial Control CAEL-DP Series Dew Point Transmitter for Industrial Control SERIAL's latest CAEL series Dew Point transmitter meets the harsh environmental requirements for Dew Point measurement. Via temperature and relative

More information

ECON-ZIP-BASE. ZIP Economizer Base Unit. Wiring Diagram USA CANADA LATIN AMERICA / CARIBBEAN

ECON-ZIP-BASE. ZIP Economizer Base Unit. Wiring Diagram USA CANADA LATIN AMERICA / CARIBBEAN ECON-ZIP-BASE ZIP Economizer Base Unit 24 VAC ± 20%, 50/60 Hz; Class 2 power source 4 VA Base Control (ECON-ZIP-BASE) 5.5 VA Base Control with Energy Module (ECON-ZIP-BASE + ECON-ZIP-EM) Power Consumption

More information

Pre-programmed room controller with display and communication

Pre-programmed room controller with display and communication revision 10 2017 RC-C3DOC Pre-programmed room controller with display and communication RC-C3DOC is a complete pre-programmed room controller from the Regio Midi series intended to control heating, cooling

More information

Features BACnet/IP over Wi-Fi, BACnet MS/TP, Delta LINKnet communication. EnOcean wireless for zone-level control, including sensors and outputs

Features BACnet/IP over Wi-Fi, BACnet MS/TP, Delta LINKnet communication. EnOcean wireless for zone-level control, including sensors and outputs Wireless BACnet Thermostat: ezntw Description The ezntw is a fully programmable thermostat equipped with EnOcean wireless connectivity and onboard Wi-Fi option. Featuring a standard temperature sensor

More information

Multi-Point Gas Detection and Control System

Multi-Point Gas Detection and Control System Multi-Point Gas Detection and Control System Specifications subject to change without notice. USA 50729 Page of 9 DESCRIPTION Wall mounted, microprocessor-based, multi-point, analog electronic control

More information

OEM Digital NDIR CO 2

OEM Digital NDIR CO 2 OEM Digital NDIR CO 2 sensor with flow-through gas cell Model 2015SPI-3 The VALTRONICS Model 2015SPI-3 is an OEM NDIR CO 2 sensor with digital signal processing and temperature compensation. The firmware

More information

Auto-timer Datalogging Temperature / Humidity Meter

Auto-timer Datalogging Temperature / Humidity Meter RS Stock No.712-6042 Instruction Manual RS-1365 Auto-timer Datalogging Temperature / Humidity Meter EN FR IT DE ES TABLE OF CONTENTS / EN TABLE OF CONTENTS TITLE PAGE 1. SPECIFICATIONS... 1 2. FRONT PANEL

More information

USER S MANUAL. DAS-G01 The Power of Tomorrow

USER S MANUAL. DAS-G01 The Power of Tomorrow USER S MANUAL DAS-G01 The Power of Tomorrow Richmond Heights 2018 0 USER S MANUAL DAS-G01 The Power of Tomorrow Richmond Heights 2018 Page 1 USER'S MANUAL TABLE OF CONTENTS Page # 1.0 GENERAL INFORMATION...

More information

GMM220 CO 2. Transmitter Modules. Introduction. Mounting

GMM220 CO 2. Transmitter Modules. Introduction. Mounting Introduction GMM220 CO 2 Transmitter Modules Vaisala GMM220 transmitter modules are versatile instruments for measuring CO 2 in industrial applications. The CARBOCAP sensor is silicon based and its operation

More information

02/11/2015

02/11/2015 48 x 48 Max. Counting Speed 5 KHZ Green backlit LCD display Part number 87629111 Counter, Preselection chronometer Maximum input frequency 5 k Hz Simple parameter setting, configuration using text menus

More information

THERMOSTATS & CONTROLLERS

THERMOSTATS & CONTROLLERS DESCRIPTION The Belimo ZIP Economizer Series saves energy in buildings by using cool outside air as a means of cooling the indoor space. This application can drastically reduce HVAC energy costs while

More information

Product Specification. CO 2 Engine K33-LP T. Sensor Module and OEM Platform. Document PSP0120. Rev 4. Page 1 (13)

Product Specification. CO 2 Engine K33-LP T. Sensor Module and OEM Platform. Document PSP0120. Rev 4. Page 1 (13) Product Specification CO 2 Engine K33-LP T Sensor Module and OEM Platform 1 (13) General The K33 sensor platform CO 2 Engine K33-LP T is designed to be a low power OEM module for built-in applications

More information

FTM84/85 Feature Application. Temperature & Humidity / Flow Measuring Specialist

FTM84/85   Feature Application. Temperature & Humidity / Flow Measuring Specialist FTM84/85 Feature Application IP65 protection degree, rugged aluminum case, fit in variety harsh environment Capable of temperature compensation Llinear adjustment air velocity by computer, analogue output

More information

User s Guide TG Series C. Senva Sensors 9290 SW Nimbus Ave Beaverton, OR 97008

User s Guide TG Series C. Senva Sensors 9290 SW Nimbus Ave Beaverton, OR 97008 User s Guide TG Series Senva Sensors 9290 SW Nimbus Ave Beaverton, OR 97008 154-0031-0C Rev. Release Date By Description of Change ECR 0A 4/14/2016 CKB Initial Release --- 0B 3/7/2017 CKB Updated for RS485

More information

Fast Route to Reliable Energy Savings ZIP Economizer

Fast Route to Reliable Energy Savings ZIP Economizer Fast Route to Reliable Energy Savings ZIP Economizer LCD Display Automotive quality, easy-to-read display allows easy verifi cation of set values and real time operating information Alarm Notification

More information

Z-LINE Z201 Z-L LINE. AC Current. to DC ma/v isolator/converter CONVERTERS AND INTERFACES. Electric parameters conv verters

Z-LINE Z201 Z-L LINE. AC Current. to DC ma/v isolator/converter CONVERTERS AND INTERFACES. Electric parameters conv verters CONVERTERS AND INTERFACES AC Current Z-LINE Z201 to DC ma/v isolator/converter Z-L LINE Electric parameters conv verters INPUT:N.1 channel current 0..5 Aac or 0..10 Aac OUTPUT:N.1 channel current 0..20,

More information

Pre-programmed room controller with display and communication

Pre-programmed room controller with display and communication revision 01 2014 RC-C3DOC Pre-programmed room controller with display and communication RC-C3DOC is a complete pre-programmed room controller from the Regio Midi series intended to control heating, cooling

More information

Vaisala Veriteq VL 2000 Temperature Humidity Loggers

Vaisala Veriteq VL 2000 Temperature Humidity Loggers Vaisala Veriteq VL 2000 Temperature Humidity Loggers Vaisala s Veriteq VL 2000 series loggers are fully validatable and designed for regulated industries/pharmaceutical applications with NIST-traceable,

More information

FCU-MULTI Modbus Fan Coil Unit Controller

FCU-MULTI Modbus Fan Coil Unit Controller Product Sheet CT2.61 Controller Type FCU-MULTI FCU-MULTI Modbus Fan Coil Unit Controller FCU-MULTI is completely stand-alone operating room controller designed for room heating, cooling, ventilation, lighting

More information

sensor, which compensates for ageing effects, is highly insensitive to pollution and offers outstanding long term stability.

sensor, which compensates for ageing effects, is highly insensitive to pollution and offers outstanding long term stability. USER S GUIDE EE800 - HVAC Room Transmitter for CO 2, Temperature and Relative Humidity GENERAL EE800 combines CO 2, temperature (T) and relative humidity (RH) measurement in one device with modern design.

More information

SE7600E Series Application Guide

SE7600E Series Application Guide Schneider Electric SE7600E Series RTU Controller with IAQ Control Application Guide CONTENTS Solution Overview 2 Product Overview 3 Features & Benefits 3 System Overview & Architecture 4 Models Available

More information

LLR-MOD Modbus Light Level and Occupancy Sensor

LLR-MOD Modbus Light Level and Occupancy Sensor Product sheet SN1.418 Type LLR-MOD LLR-MOD Modbus Light Level and Occupancy Sensor The LLR-MOD sensors are designed to measure Light Level (LUX) in the room spaces and have built-in RS485 Modbus communication

More information

Output signal. 22DTM-16 BACnet DC V, DC V. Electrical data Power supply DC V, ±10%, 0.3 W

Output signal. 22DTM-16 BACnet DC V, DC V. Electrical data Power supply DC V, ±10%, 0.3 W Duct Sensor CO₂ / Humidity / Temperature For combined measurement of CO₂, relative humidity and temperature in the duct. Dual channel CO₂ technology. The measured values are output via BACnet. NEMA 4X

More information

NSGV Series "90DM3" Carbon Dioxide Detector

NSGV Series 90DM3 Carbon Dioxide Detector NSGV SERIES 90DM3 CARBON DIOXIDE DETECTOR NSGV Series "90DM3" Carbon Dioxide Detector 90DM3A Specifications. Power 17-27 VAC, 24-38 VDC, 200 ma Detection Range 0-200 PPM Relay Output Rating 5A, 30 Vdc

More information

DMT345 and DMT346 Dewpoint Transmitters

DMT345 and DMT346 Dewpoint Transmitters DMT345 and DMT346 Dewpoint Transmitters for High Temperature Applications Features DMT345 measures humidity at temperatures up to 180 C (356 F) DMT346 measures humidity at temperatures up to 350 C (+662

More information

Analog input module. Data sheet. for MULTICAL 603

Analog input module. Data sheet. for MULTICAL 603 Data sheet Analog input module for MULTICAL 603 Two analog inputs, selectable as 0...20mA or 0...10V Individual scaling of measuring ranges Individual setup of measuring unit and decimal point Selectable

More information

NDIR GAS SENSOR SPECIALIST

NDIR GAS SENSOR SPECIALIST Mega wave of overwhelming change with the world s smallest NDiR sensors of ELT SENSOR NDIR GAS SENSOR SPECIALIST WITH NEW TECH & RELIABLE PARTNER ELT SENSOR Corp. (Chunui Technopark 101-909) 36, Bucheon-ro

More information

Gas Analyzers Components for Gas Analysis

Gas Analyzers Components for Gas Analysis 2.2 2 Contents Modular Gas Analyzer DX6100 Series.......................................23 Advantages...........................................................23 Design Features.........................................................24

More information

Dew point. Dew point set DS 400. Special features: Dew point set DS 400. Technical data DS 400. Technical data FA 410

Dew point. Dew point set DS 400. Special features: Dew point set DS 400. Technical data DS 400. Technical data FA 410 Dew point set DS 400 for stationary dew point monitoring of refrigeration or adsorption dryers. The touch screen graphic display enables an intuitive operation and shows the progress of the measured values.

More information

Personal Sound Level Meter

Personal Sound Level Meter User's Guide Personal Sound Level Meter Model SL10 Introduction Congratulations on your purchase of the Extech SL10 Personal Sound Level Meter. The SL10 measures and displays sound pressure levels in db

More information

TER-MOD Active Room Temperature Sensors (Controllers) with Modbus

TER-MOD Active Room Temperature Sensors (Controllers) with Modbus Product sheet TER Type TER-MOD TER-MOD Active Room Temperature Sensors (Controllers) with Modbus The TER-MOD active sensors are designed to detect temperature in the room spaces and have built-in RS485

More information

KCD-HP. KCD-HP200x, 300X. [Figures] Top : 1% Sensor probe Bottom left : 10% / 20% Sensor probe Bottom right : Holding bracket(optional) Measurement

KCD-HP. KCD-HP200x, 300X. [Figures] Top : 1% Sensor probe Bottom left : 10% / 20% Sensor probe Bottom right : Holding bracket(optional) Measurement Our CO2 gas sensors get a small deviation unlike NDIR Single type. So they keep long term stability. KCD-HP100x Excellent stability and accuracy - through testing and calibration with sophisticated process

More information

ZG07 CO2 Module. ZG07 series CO2 Module. User Manual

ZG07 CO2 Module. ZG07 series CO2 Module. User Manual ZG07 series CO2 Module User Manual Contents 1 GENERAL DESCRIPTION... 3 2 FEATURES OF DESIGN... 3 3 SPECIFICATION... 4 PIN ASSIGNMENT OF ZG07... 5 3.1 TIMING OF SPIR... 6 3.1.1 Format of Message... 7 1

More information

Industrial. Laboratory and Field. Accessories. Product Selection Guide. Analyzers 1 Controllers 2 Transmitters 3 Monitors 4

Industrial. Laboratory and Field. Accessories. Product Selection Guide. Analyzers 1 Controllers 2 Transmitters 3 Monitors 4 Product Selection Guide Industrial Analyzers 1 Controllers 2 Transmitters 3 Monitors 4 Laboratory and Field Benchtop Meters 5 Field Meters 5 Benchtop Controllers 7 Pocket Meters & Testers 9 Accessories

More information

Room controller STRA-17

Room controller STRA-17 Room controller STRA-17 Application example Room 2 Room 3 Room 4 SCADA EXOline alt. RS485 Modbus Transformer STRZ-24 (Required component) STRA-17 is a preprogrammed room controller intended to control

More information

HLS34 Modbus FCU/VAV Controllers installation instructions

HLS34 Modbus FCU/VAV Controllers installation instructions HLS34 Modbus FCU/VAV Controllers installation instructions The HLS34 is specifically designed for individual room temperature and zone control applications. The controllers have built-in RS-485 channel

More information

TR-7wf Series. and Infrared / USB Data Loggers TR-7Ui Series

TR-7wf Series. and Infrared / USB Data Loggers TR-7Ui Series TR-7wf Series and Infrared / USB Data Loggers TR-7Ui Series TR-7wf Series TR-7wf Series Next Generation Data Loggers-Built for Cloud Storage Seamless Data Access T&D Cloud Service Free of Charge! Automatic

More information

Dräger Polytron IR. Dräger Polytron IR: Configurable gas detector for reliable detection of combustible gases and vapours.

Dräger Polytron IR. Dräger Polytron IR: Configurable gas detector for reliable detection of combustible gases and vapours. DETECTION PERSONAL PROTECTION DIVING TECHNOLOGY SYSTEM TECHNOLOGY SERVICES Dräger Polytron IR ST-3949-2004 The Dräger Polytron IR is an explosion proof infrared gas detector for continuous monitoring of

More information

RHR-MOD Combined Room Temperature and Humidity Sensors (Controllers) with Modbus

RHR-MOD Combined Room Temperature and Humidity Sensors (Controllers) with Modbus Product sheet SN1.411 Type RHR-MOD RHR-MOD Combined Room Temperature and Humidity Sensors (Controllers) with Modbus The RHR-MOD sensors are designed to detect relative humidity and temperature in the room

More information

GEN II Wireless GSM/GPRS Data Acquisition System

GEN II Wireless GSM/GPRS Data Acquisition System Real time and historic data is sent via GPRS to the main server where it is written to a MySQL database Server MySQL Database SMS alarm messages sent to mobile phones Email alerts and reports sent to specified

More information

Instruction Manual CTC-1

Instruction Manual CTC-1 Troubleshooting & Specs CTC-1 Amps / Volts requirements Min / Max operating temperature Min / Max operating Humidity Temperature Measurement range Temperature Accuracy CO2 sensor type CO2 Measurement range

More information

Rev Carbon Dioxide (CO2) Gas Sensor. TG100 User Manual

Rev Carbon Dioxide (CO2) Gas Sensor. TG100 User Manual Rev. 2.5 TG100 User Manual The TG100 measuring carbon dioxide (chemical formula CO2) is a NDIR (Non-Dispersive Infrared) gas sensor. As it is contactless, it has high accuracy and longer life than sensors

More information

English. Operating manual. Transmitters / regulators HD45 HD46. Keep for future reference. Companies / Brands of GHM

English. Operating manual. Transmitters / regulators HD45 HD46.   Keep for future reference. Companies / Brands of GHM English Operating manual Transmitters / regulators HD45 HD46 Companies / Brands of GHM www.deltaohm.com Keep for future reference. 1. INTRODUCTION The instruments of the HD45 and HD46 series are transmitters,

More information

Programmable temperature transducer from Pt1000 sensor to current loop 4-20 ma Instruction Manual

Programmable temperature transducer from Pt1000 sensor to current loop 4-20 ma Instruction Manual T4111 TRANSDUCER Programmable temperature transducer from Pt1000 sensor to current loop 4-20 ma Instruction Manual Instruction manual for use of T4111 transducer Transducer is designed for temperature

More information

RCW-400A USER GUIDE. Version 1.1

RCW-400A USER GUIDE. Version 1.1 RCW-400A USER GUIDE Version 1.1 User Guide Chapter I Product Introduction1 1.1 Overview 1.2 Features and functions Chapter II Instructions for Use 2.1 Product Display 2.1.1 Interface 2.1.2 LCD display

More information

A C C S for Road Tunnels. NOVICOM CO/NO/Visibility Monitor Contact us for Information about:

A C C S for Road Tunnels. NOVICOM CO/NO/Visibility Monitor Contact us for Information about: NOVICOM Contact us for Information about: Air Flow Monitors Photometers NO2 (Nitrogen Dioxide) Monitoring Visibility Monitors NOx Monitoring CO Monitoring Various combinations of the above instruments

More information

STANDARD OPERATING PROCEDURES SOP : 1736 PAGE: 1 of 35 REV: 0.0 DATE: 09/25/06 MEASUREMENT OF AIR CHANGES USING THE WOLFSENSE IAQ PROBE

STANDARD OPERATING PROCEDURES SOP : 1736 PAGE: 1 of 35 REV: 0.0 DATE: 09/25/06 MEASUREMENT OF AIR CHANGES USING THE WOLFSENSE IAQ PROBE PAGE: 1 of 35 CONTENTS 1.0 SCOPE AND APPLICATION 2.0 METHOD SUMMARY 3.0 SAMPLE PRESERVATION, CONTAINERS, HANDLING, AND STORAGE 4.0 INTERFERENCES AND POTENTIAL PROBLEMS 5.0 EQUIPMENT/APPARATUS 6.0 REAGENTS

More information

Application. Types Available. Duct sensor for air quality, temperature and humidity (optional) Datasheet

Application. Types Available. Duct sensor for air quality, temperature and humidity (optional) Datasheet LK+ CO2+VOC Duct sensor for air quality, temperature and humidity (optional) Datasheet Subject to technical alteration Issue date: 04.04.2018 A002 Application Duct air quality sensor for detection of CO2,

More information

GS828-H. GPRS Data Logger

GS828-H. GPRS Data Logger GPRS Data Logger GS828-H Multi Channels Data Logging & Wireless Transmission Upload Data via GPRS and SMS on schedule or alarm triggered Programmable data logging and upload interval Support sensors via

More information

AIR HANDLING UNIT CONTROLS

AIR HANDLING UNIT CONTROLS AIR HANDLING UNIT CONTROLS STAND ALONE / INDEPENDENT OPERATION BMS INTERFACE (BACnet - B/IP, ETHERNET, MS/TP AND PTP MODBUS) Standalone Panels: CONTROLS OVERVIEW On a standalone panel, a touch screen display

More information

ON/OFF HUMIDIFIER CONTROL (ROOM 0R DUCT SENSOR) WITH OUTDOOR TEMPERATURE RESET OVERVIEW WALL CONTROLLER INSTALLATION (TCY-BH-T-U)

ON/OFF HUMIDIFIER CONTROL (ROOM 0R DUCT SENSOR) WITH OUTDOOR TEMPERATURE RESET OVERVIEW WALL CONTROLLER INSTALLATION (TCY-BH-T-U) (ROOM 0R DUCT SENSOR) WITH OUTDOOR TEMPERATURE RESET TCY-BH-T-U Wall controller with sensor TDC-BH-T-U Duct controller with sensor SOA-Tn10 Outdoor temperature sensor (Optional) OVERVIEW For wall applications

More information

Hand-Held Pressure Indicator

Hand-Held Pressure Indicator Hand-Held Pressure Indicator Model CPH 6200 Model CPH 6200-S2 (2-channel version) Model CPH 62I0 (intrinsically safe version) WIKA Data Sheet CT 11.01 Applications Calibration service companies / service

More information

RC-CDTO. Pre-programmed room controller with display, communication and three-point control

RC-CDTO. Pre-programmed room controller with display, communication and three-point control revision 02 2016 RC-CDTO Pre-programmed room controller with display, communication and three-point control RC-CDTO is a complete pre-programmed room controller from the Regio Midi series intended to control

More information

PCD-400A/430A. Sensor Interface. Carrier Wave Type Compact and Moderate Prices. Data Recorders/Analyzers MEASURING INSTRUMENTS

PCD-400A/430A. Sensor Interface. Carrier Wave Type Compact and Moderate Prices. Data Recorders/Analyzers MEASURING INSTRUMENTS 3-77 Sensor Interface 3-77 PCD-400A Carrier Wave Type Compact and Moderate Prices Easy sensor connection using various types of input adapters Connects to PC using USB interface Measurement using 1 unit

More information

BESANTEK USB Data Logger Instructional Manual (BST-DL10, BST-DL13, BST-DL14)

BESANTEK USB Data Logger Instructional Manual (BST-DL10, BST-DL13, BST-DL14) BESANTEK USB Data Logger Instructional Manual (BST-DL10, BST-DL13, BST-DL14) BESANTEK USB Data Logger Instructional Manual (BST-DL10, BST-DL13, BST-DL14) CONTENTS Chapter 1. USB Data Logger Hardware...1

More information