Megan A. Wood, M.S. Under the direction of Larry DeWerd, Ph.D. University of Wisconsin Medical Radiation Research Center (UWMRRC)
|
|
- Howard Newton
- 5 years ago
- Views:
Transcription
1 Megan A. Wood, M.S. Under the direction of Larry DeWerd, Ph.D. University of Wisconsin Medical Radiation Research Center (UWMRRC) NCCAAPM Spring Meeting May 3, 2013
2 Introduction FFF background Project motivation Materials and Methods Phase space files BEAMnrc linac model Commissioning data acquisition Results Measured vs modeled Conclusions and Future Direction 2
3 FFF studies began as early as The motivation for widespread FFF availability was the advent of IMRT Flattening + modulation throws away dose rate Faster treatments may be beneficial for some patients The recently released Varian TrueBeam TM is the first commercial C-arm linac with FFF capability 1. P. F. O Brien, B. A. Gillies, M. Schwartz, C. Young, and P. Davey, Radiosurgery with unflattened 6-MV photon beams, Med. Phys. 18(3), (1991) 2. (Image source) 3
4 Changes that will affect dosimetry: Profile shape Softer spectrum Higher dose rate 1. (Image source) O. N. Vassiliev, U. Titt, F. Pӧnisch, S. F. Kry, R. Mohan, and M. T. Gillin, Dosimetric properties of photon beams from a flattening filter free clinical accelerator, Phys. Med. Biol. 51(7), (2006) 4
5 1. (Image source) E. S. M. Ali and D. W. O. Rogers, Functional forms for photon spectra of clinical linacs, Phys Med Biol 57, (2012) 5
6 From Georg et al. (2011) several aspects related to standardization, dosimetry and dose determination, treatment planning, and radiobiology need to be addressed for a widespread clinical implementation of unflattened beams A reliable, benchmarked linac model is a crucial component of a comprehensive dosimetric study 1. D. Georg, T. Knoos, and B. McClean, Current status and future perspective of flattening filter free photon beams, Med. Phys. 38 (3), (2011) 6
7 Varian provides IAEA-compliant phase space files above the jaws Keeps upper linac components proprietary Standardizes simulations across researchers These files contain particle data from their GEANT4 simulations Position, direction, energy, particle type, etc. Matched to Golden Beam data, not individual machines Full phase space is split into 55 files, each 1 GB 1. Varian correspondence, Varian Monte Carlo data package 7
8 EGSnrc currently has a phase space size limitation of 2 GB Is it necessary to use every phase space file in the set to get accurate results? Combination tests were performed, comparing PDDs with each individual file to those resulting from all files combined 8
9 9
10 Dose (10-16 Gy per starting particle) PDD Comparison: all phsp files Depth (cm) 10
11 Conclusion of phase space combination tests: One or two phase space files can represent all, with enough histories for good statistics This solution saves time This allows a workaround for the EGSnrc 2 GB limit The NRCC is currently addressing this problem 11
12 BEAMnrc is an EGSnrc user code designed to model typical clinical linear accelerators An accelerator is built using several sections called component modules (CMs) A basic model of the TrueBeam TM was developed using the JAWS and CHAMBER modules 12
13 Jaw simplifications Solid blocks only, no bores or cutouts No arc translation Baseplate simplifications Missing many cutouts, some tungsten shielding Simplified shape to donut (no straight edges) Upper shield shortened (cannot overlap jaw CM) MLC was omitted for the preliminary comparison 13
14 A second phase space was scored after the baseplate CM in BEAMnrc This was used as the source in a DOSXYZnrc calculation of PDDs DOSXYZnrc is another user code designed for dose calculation in voxelized phantoms PDDs were scored using 0.5 x 0.5 x 0.5 cm 3 voxels along the central axis 14
15 A full set of commissioning data was acquired at the UW Carbone Cancer Center PDDs were acquired using Wellhӧfer CC13 compact scanning chambers (0.13 cm 3 ) for both reference and field IBA Blue Phantom and OmniPro Accept software were used for data collection Chamber was always shifted to the effective point of measurement 1. (Image source) Wellhofer compact chamber specification sheet, 2. (Image source) Blue Phantom specification sheet, 15
16 Dose (relative to maximum) PDD Comparison: Open 40cm x 40cm Field Measured 40x40 field Simulated open field Depth (cm) 16
17 Dose (relative to max) PDD Comparison: 10x10 Field Measured Simulated Depth (cm) 17
18 Good agreement was seen between open field and 10x10 measured and modeled results Max discrepancies were at shallowest and deepest depths: -8.2% and -6.39%, respectively All other points along PDDs agreed within 4% Better agreement should be achievable Limitations of EGSnrc/BEAMnrc Limitations of current phase space capabilities Future direction GEANT4 will be used to develop a more detailed, fully benchmarked model Varian s upcoming cloud computing platform will be used to match the model to measured data This model will be used for a comprehensive assessment of current dosimetry methods for FFF linacs 18
19 Dr. Larry DeWerd John Micka UWMRRC students and staff UWADCL customers UW Carbone Cancer Clinic TrueBeam commissioning team Charlie Wallace Dr. Jeni Smilowitz 19
20 Questions are welcome
Analysis of Radiation Transport through Multileaf Collimators Using BEAMnrc Code
American Journal of Biomedical Engineering 216, 6(4): 124-131 DOI: 1.5923/j.ajbe.21664.3 Analysis of Radiation Transport through Multileaf Collimators Using BEAMnrc Code Ankit Kajaria 1,*, Neeraj Sharma
More informationComparison of absorbed dose distribution 10 MV photon beam on water phantom using Monte Carlo method and Analytical Anisotropic Algorithm
Journal of Physics: Conference Series PAPER OPEN ACCESS Comparison of absorbed dose distribution 1 MV photon beam on water phantom using Monte Carlo method and Analytical Anisotropic Algorithm To cite
More informationStatic IMRT and VMAT planning on 6 MV Flattened and Flattening-Filter-
1 Static IMRT and VMAT planning on 6 MV Flattened and Flattening-Filter- Free Beams of a TrueBeam VirtuaLinac System Yue Yan Department of Medical Physics and Human Oncology, University of Wisconsin-Madison,
More informationAssesing multileaf collimator effect on the build-up region using Monte Carlo method
Pol J Med Phys Eng. 2008;14(3):163-182. PL ISSN 1425-4689 doi: 10.2478/v10013-008-0014-0 website: http://www.pjmpe.waw.pl M. Zarza Moreno 1, 2, N. Teixeira 3, 4, A. P. Jesus 1, 2, G. Mora 1 Assesing multileaf
More informationImplementation of the EGSnrc / BEAMnrc Monte Carlo code - Application to medical accelerator SATURNE43
International Journal of Innovation and Applied Studies ISSN 2028-9324 Vol. 6 No. 3 July 2014, pp. 635-641 2014 Innovative Space of Scientific Research Journals http://www.ijias.issr-journals.org/ Implementation
More informationMCNP4C3-BASED SIMULATION OF A MEDICAL LINEAR ACCELERATOR
Computational Medical Physics Working Group Workshop II, Sep 3 Oct 3, 7 University of Florida (UF), Gainesville, Florida USA on CD-ROM, American Nuclear Society, LaGrange Park, IL (7) MCNP4C3-BASED SIMULATION
More informationOutput factor comparison of Monte Carlo and measurement for Varian TrueBeam 6 MV and 10 MV flattening filter-free stereotactic radiosurgery system
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, VOLUME 17, NUMBER 3, 2016 Output factor comparison of Monte Carlo and measurement for Varian TrueBeam 6 MV and 10 MV flattening filter-free stereotactic radiosurgery
More informationMeasurement of depth-dose of linear accelerator and simulation by use of Geant4 computer code
reports of practical oncology and radiotherapy 1 5 (2 0 1 0) 64 68 available at www.sciencedirect.com journal homepage: http://www.rpor.eu/ Original article Measurement of depth-dose of linear accelerator
More informationCommissioning and verification of the collapsed cone convolution superposition algorithm for SBRT delivery using flattening filter-free beams
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, VOLUME 15, NUMBER 2, 2014 Commissioning and verification of the collapsed cone convolution superposition algorithm for SBRT delivery using flattening filter-free
More informationIndrin Chetty Henry Ford Hospital Detroit, MI. AAPM Annual Meeting Houston 7:30-8:25 Mon 08/07/28 1/30
Review of TG105: Issues associated with clinical implementation of Monte Carlo-based photon and electron external beam treatment planning D. W. O. Rogers, Carleton Laboratory for Radiotherapy Physics,
More informationDetermination of primary electron beam parameters in a Siemens Primus Linac using Monte Carlo simulation
Determination of primary electron beam parameters in a Siemens Primus Linac using Monte Carlo simulation Danial Seifi Makrani 1, Hadi Hasanzadeh 2*, Tayyeb Allahverdi Pourfallah 3, Arash Ghasemi 4, Majid
More informationEvaluation of latent variances in Monte Carlo dose calculations with Varian TrueBeam photon phase-spaces used as a particle source
Evaluation of latent variances in Monte Carlo dose calculations with Varian TrueBeam photon phase-spaces used as a particle source Eyad Alhakeem, 1, 2, Sergei Zavgorodni 2,1 1 Department of Physics and
More informationMonte Carlo simulation of beam characteristics from small fields based on TrueBeam flattening-filter-free mode
Feng et al. Radiation Oncology (16) 11:3 DOI 1.1186/s1314-16-1-2 RESEARCH Open Access Monte Carlo simulation of beam characteristics from small fields based on TrueBeam flattening-filter-free mode Zhongsu
More informationUse of Monte Carlo modelling in radiotherapy linac design. David Roberts, PhD Senior Physicist Elekta
Use of Monte Carlo modelling in radiotherapy linac design David Roberts, PhD Senior Physicist Elekta Contents Overview of Elekta What we do Where we use Monte Carlo Codes and resources Example : Agility
More informationValidation of GEANT4 Monte Carlo Simulation Code for 6 MV Varian Linac Photon Beam
Validation of GEANT4 Monte Carlo Code for 6 MV Varian Linac Photon Beam E. Salama ab*, A.S. Ali c, N. Emad d and A. Radi a a Physics Department, Faculty of Science, Ain Shams University, Cairo, Egypt;
More informationComparison Study of Monte Carlo Simulations and Measurements of Relative Output Factors of 6 MV Photon Beam
Comparison Study of Monte Carlo Simulations and Measurements of Relative Output Factors of 6 MV Photon Beam Nakorn Phaisangittisakul 1*, Wanchaloem Saprangsi 2, Chirapha Tannanonta 2 and Sivalee Suriyapee
More informationImplementation of a double Gaussian source model for the BEAMnrc Monte Carlo code and its influence on small fields dose distributions
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, VOLUME 17, NUMBER 5, 2016 Implementation of a double Gaussian source model for the BEAMnrc Monte Carlo code and its influence on small fields dose distributions
More informationPreface. Med. Phys. 35(9), , Mechanical QA. Radiation Survey Mechanical tests Light radiation Table, Collimator, Gantry Jaws.
AAPM-SAM-2012-Das (1) Beam Data Collection and Commissioning for Linear Accelerators: Technical Considerations and Recommendations Preface Indra J. Das, PhD, FAAPM, FACR, FASTRO Department of Radiation
More informationMonte Carlo modeling of a Novalis TX Varian 6 MV with HD-120 multileaf collimator
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, VOLUME 13, NUMBER 5, 2012 Monte Carlo modeling of a Novalis TX Varian 6 MV with HD-120 multileaf collimator Luis Alberto Vazquez-Quino, 1 Brian Massingill,
More informationFAST, precise. qa software
qa software FAST, precise Software for accurate and independent verification of monitor units, dose, and overall validity of standard, IMRT, rotational or brachytherapy plans no film, no phantoms, no linac
More informationMonte Carlo Methods for Accelerator Simulation and Photon Beam Modeling
Monte Carlo Methods for Accelerator Simulation and Photon Beam Modeling AAPM Summer School 2006 Windsor, ON Part I Daryoush Sheikh-Bagheri, PhD Allegheny General Hospital Pittsburgh, PA A sample of work
More informationDevelopment a simple point source model for Elekta SL-25 linear accelerator using MCNP4C Monte Carlo code
Iran. J. Radiat. Res., 2006; 4 (1): 7-14 Development a simple point source model for Elekta SL-25 linear accelerator using MCNP4C Monte Carlo code. Mesbahi * Department of Medical Physics, Medical School,
More informationSource Model Tuning for a 6 MV Photon Beam used in Radiotherapy
Journal of Physics: Conference Series Source Model Tuning for a 6 MV Photon Beam used in Radiotherapy To cite this article: Lukas A Hirschi et al 2007 J. Phys.: Conf. Ser. 74 021008 View the article online
More informationMonte Carlo Simulation for Neptun 10 PC Medical Linear Accelerator and Calculations of Electron Beam Parameters
Monte Carlo Simulation for Neptun 1 PC Medical Linear Accelerator and Calculations of Electron Beam Parameters M.T. Bahreyni Toossi a, M. Momen Nezhad b, S.M. Hashemi a a Medical Physics Research Center,
More informationBRAZILIAN JOURNAL OF RADIATION SCIENCES (2018) 01-14
BJRS BRAZILIAN JOURNAL OF RADIATION SCIENCES 06-02 (2018) 01-14 Experimental verification of a methodology for Monte Carlo modeling of multileaf collimators using the code Geant4 A. C. Holanda de Oliveira
More informationMonte Carlo evaluation of the dosimetric uncertainty in matched 6 MV Elekta and Varian linear accelerators
Monte Carlo evaluation of the dosimetric uncertainty in matched 6 MV Elekta and Varian linear accelerators Dr Jessica E Lye PhD, BSc Hons. A thesis submitted in partial fulfilment of the requirements for
More informationThree-dimensional dosimetry of small fields
Three-dimensional of small fields Travis J. McCaw Medical Radiation Research Center Department of Medical Physics University of Wisconsin, Madison, WI NCCAAPM 2013 Fall Meeting 10 October 2013 Medical
More informationTransitioning from pencil beam to Monte Carlo for electron dose calculations
Transitioning from pencil beam to Monte Carlo for electron dose calculations Jessie Huang-Vredevoogd (jyhuang4@wisc.edu) University of Wisconsin NCC AAPM October 12, 2019 1 Topics to cover Background RayStation
More informationA Geant4 based treatment plan verification tool: commissioning of the LINAC model and DICOM-RT interface
A Geant4 based treatment plan verification tool: commissioning of the LINAC model and DICOM-RT interface Iwan Cornelius, Chris Poole. Stephen Warwick, Christian Langton Discipline of Physics, Faculty of
More information87.55.K-, Gh, km, Ca. Agility, analytic model, Elekta, Monaco, Monte Carlo, virtual source
Received: 14 May 2018 Revised: 21 September 2018 Accepted: 27 September 2018 DOI: 10.1002/acm2.12485 RADIATION ONCOLOGY PHYSICS Monte Carlo and analytic modeling of an Elekta Infinity linac with Agility
More informationAn investigation into the use of MMCTP to tune accelerator source parameters and testing its clinical application
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, VOLUME 14, NUMBER 2, 2013 An investigation into the use of MMCTP to tune accelerator source parameters and testing its clinical application Elaine Conneely,
More informationIMSURE QA SOFTWARE FAST, PRECISE QA SOFTWARE
QA SOFTWARE FAST, PRECISE Software for accurate and independent verification of monitor units, dose, and overall validity of standard, IMRT, VMAT, SRS and brachytherapy plans no film, no phantoms, no linac
More informationInvestigation of tilted dose kernels for portal dose prediction in a-si electronic portal imagers
Investigation of tilted dose kernels for portal dose prediction in a-si electronic portal imagers Krista Chytyk MSc student Supervisor: Dr. Boyd McCurdy Introduction The objective of cancer radiotherapy
More informationOutline. Outline 7/24/2014. Fast, near real-time, Monte Carlo dose calculations using GPU. Xun Jia Ph.D. GPU Monte Carlo. Clinical Applications
Fast, near real-time, Monte Carlo dose calculations using GPU Xun Jia Ph.D. xun.jia@utsouthwestern.edu Outline GPU Monte Carlo Clinical Applications Conclusions 2 Outline GPU Monte Carlo Clinical Applications
More informationA SYSTEM OF DOSIMETRIC CALCULATIONS
A SYSTEM OF DOSIMETRIC CALCULATIONS INTRODUCTION Dose calculation based on PDD and TAR have Limitations The dependence of PDD on SSD Not suitable for isocentric techniques TAR and SAR does not depend on
More informationTPS COMMISSIONING. Laurence Court University of Texas MD Anderson Cancer Center 4/3/2017 1
TPS COMMISSIONING Laurence Court University of Texas MD Anderson Cancer Center 4/3/2017 1 Conflicts of interest Court receives funding from NIH, CPIRT, Varian and Elekta 4/3/2017 2 Resources your first
More informationTHE SIMULATION OF THE 4 MV VARIAN LINAC WITH EXPERIMENTAL VALIDATION
2007 International Nuclear Atlantic Conference - INAC 2007 Santos, SP, Brazil, September 30 to October 5, 2007 ASSOCIAÇÃO BRASILEIRA DE ENERGIA NUCLEAR - ABEN ISBN: 978-85-99141-02-1 THE SIMULATION OF
More informationUse of a commercial ion chamber detector array for the measurement of high spatial resolution photon beam profiles
Received: 17 January 2018 Revised: 27 August 2018 Accepted: 31 August 2018 DOI: 10.1002/acm2.12466 TECHNICAL NOTE Use of a commercial ion chamber detector array for the measurement of high spatial resolution
More informationImprovements in Monte Carlo simulation of large electron fields
SLAC-PUB-12908 October 2007 Improvements in Monte Carlo simulation of large electron fields Bruce A Faddegon 1, Joseph Perl 2 and Makoto Asai 2 1 University of California San Francisco Comprehensive Cancer
More informationAir Kerma Strength Measurements and Monte Carlo based Dosimetric Characterization of a directional Pd 103 planar source array.
Air Kerma Strength Measurements and Monte Carlo based Dosimetric Characterization of a directional Pd 103 planar source array. MANIK AIMA UWMRRC, MADISON 2014 NCAAPM Autumn Meeting October 24 th, 2014
More informationRoom scatter effects in Total Skin Electron Irradiation: Monte Carlo simulation study
Received: 9 November 2016 Revised: 9 November 2016 Accepted: 28 November 2016 DOI: 10.1002/acm2.12039 RADIATION ONCOLOGY PHYSICS Room scatter effects in Total Skin Electron Irradiation: Monte Carlo simulation
More informationDAILY LINAC QA BEAM QA
BEAM QA DAILY LINAC QA The QA BeamChecker Plus allows for fast, reliable, and uncomplicated daily QA of Varian, Elekta, Siemens, and Accuray Treatment Machines. The QA BeamChecker Plus is specifically
More informationMonte Carlo Treatment Planning: Implementation of Clinical Systems
Monte Carlo Treatment Planning: Implementation of Clinical Systems Richard Popple 1 and Joanna E. Cygler 2,3,4 1 Department of Radiation Oncology, The University of Alabama at Birmingham 2 The Ottawa Hospital
More informationClinical implementation of photon beam flatness measurements to verify beam quality
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, VOLUME 16, NUMBER 6, 2015 Clinical implementation of photon beam flatness measurements to verify beam quality Simon Goodall, a Nicholas Harding, Jake Simpson,
More informationA DOSIMETRIC MODEL FOR SMALL-FIELD ELECTRON RADIATION THERAPY A CREATIVE PROJECT (3 SEMESTER HOURS) SUBMITTED TO THE GRADUATE SCHOOL
A DOSIMETRIC MODEL FOR SMALL-FIELD ELECTRON RADIATION THERAPY A CREATIVE PROJECT (3 SEMESTER HOURS) SUBMITTED TO THE GRADUATE SCHOOL IN PARTIAL FULFILLMENT OF THE REQUIREMENTS FOR THE DEGREE MASTER OF
More informationMachine and Physics Data Guide
WWW..COM Machine and Physics Data Guide STANDARD IMAGING, INC. 3120 Deming Way Middleton, WI 53562-1461 May / 2008 2008 Standard Imaging, Inc. TEL 800.261.4446 TEL 608.831.0025 FAX 608.831.2202 www.standardimaging.com
More informationComparison of Two Phantoms for End-to-End SRS/SBRT Testing. Vikren Sarkar, Ph.D. Associate Professor University of Utah Huntsman Cancer Center
Comparison of Two Phantoms for End-to-End SRS/SBRT Testing Vikren Sarkar, Ph.D. Associate Professor University of Utah Huntsman Cancer Center Disclosure Travel and Speaker Honorarium from Sun Nuclear Corp.
More informationTomoTherapy Related Projects. An image guidance alternative on Tomo Low dose MVCT reconstruction Patient Quality Assurance using Sinogram
TomoTherapy Related Projects An image guidance alternative on Tomo Low dose MVCT reconstruction Patient Quality Assurance using Sinogram Development of A Novel Image Guidance Alternative for Patient Localization
More informationIntensity-modulated radiation therapy dose maps: the matchline effect
University of Wollongong Research Online University of Wollongong Thesis Collection 1954-2016 University of Wollongong Thesis Collections 2006 Intensity-modulated radiation therapy dose maps: the matchline
More informationEffects of the difference in tube voltage of the CT scanner on. dose calculation
Effects of the difference in tube voltage of the CT scanner on dose calculation Dong Joo Rhee, Sung-woo Kim, Dong Hyeok Jeong Medical and Radiological Physics Laboratory, Dongnam Institute of Radiological
More informationOn compensator design for photon beam intensity-modulated conformal therapy
On compensator design for photon beam intensity-modulated conformal therapy Steve B. Jiang a) and Komanduri M. Ayyangar Department of Radiation Therapy, Medical College of Ohio, 3000 Arlington Avenue,
More informationVerification measurements of an emc algorithm using a 2D ion chamber array
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, VOLUME 17, NUMBER 5, 2016 Verification measurements of an emc algorithm using a 2D ion chamber array Mark D. Wanklyn, 1a Ghirmay Kidane, 2 and Liz Crees 2 Medical
More informationAdvanced Radiotherapy
Advanced Radiotherapy IBA Concept for IMRT Verification Dr. Lutz Müller 1 IMRT Verification BIS BIS ADAS Fluence Model Delivered fluence Target Volume Constraints Inverse Backprojection Fluence Map Leaf
More informationDose Calculation and Optimization Algorithms: A Clinical Perspective
Dose Calculation and Optimization Algorithms: A Clinical Perspective Daryl P. Nazareth, PhD Roswell Park Cancer Institute, Buffalo, NY T. Rock Mackie, PhD University of Wisconsin-Madison David Shepard,
More informationAcceptance Testing and Commissioning of Monte Carlo Dose Calculation Systems. Bruce Curran University of Michigan Medical Center Ann Arbor, MI
Acceptance Testing and Commissioning of Monte Carlo Dose Calculation Systems Bruce Curran University of Michigan Medical Center Ann Arbor, MI Disclosure Some of the work discussed in this talk was supported
More informationA virtual photon energy fluence model for Monte Carlo dose calculation
A virtual photon energy fluence model for Monte Carlo dose calculation Matthias Fippel, a) Freddy Haryanto, Oliver Dohm, and Fridtjof Nüsslin Abteilung für Medizinische Physik, Universitätsklinikum Tübingen,
More informationRadiation Beam Characterization and Dosimetry of Theratron Equinox-80 Telecobalt Machine Using BEAMnrc Monte Carlo Simulation Code
International Journal of Medical Physics, Clinical Engineering and Radiation Oncology, 2016, 5, 298-316 http://www.scirp.org/journal/ijmpcero ISSN Online: 2168-5444 ISSN Print: 2168-5436 Radiation Beam
More informationTomotherapy Physics. Machine Twinning and Quality Assurance. Emilie Soisson, MS
Tomotherapy Physics Machine Twinning and Quality Assurance Emilie Soisson, MS Tomotherapy at UW- Madison Treating for nearly 5 years Up to ~45 patients a day on 2 tomo units Units twinned to facilitate
More informationPhoton Energy Spectrum Reconstruction Based on Monte Carlo and Measured Percentage Depth Dose in Accurate Radiotherapy
Progress in NUCLEAR SCIENCE and TECHNOLOGY, Vol., pp.160-164 (011) ARTICLE Photon Energy Spectrum Reconstruction Based on Monte Carlo and Measured Percentage Depth Dose in Accurate Radiotherapy Gui LI
More informationADVANCING CANCER TREATMENT
The RayPlan treatment planning system makes proven, innovative RayStation technology accessible to clinics that need a cost-effective and streamlined solution. Fast, efficient and straightforward to use,
More informationJOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, VOLUME 7, NUMBER 3, SUMMER 2006
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, VOLUME 7, NUMBER 3, SUMMER 2006 Evaluation of dosimetric effect of leaf position in a radiation field of an 80-leaf multileaf collimator fitted to the LINAC
More informationDose Distributions. Purpose. Isodose distributions. To familiarize the resident with dose distributions and the factors that affect them
Dose Distributions George Starkschall, Ph.D. Department of Radiation Physics U.T. M.D. Anderson Cancer Center Purpose To familiarize the resident with dose distributions and the factors that affect them
More informationMichael Speiser, Ph.D.
IMPROVED CT-BASED VOXEL PHANTOM GENERATION FOR MCNP MONTE CARLO Michael Speiser, Ph.D. Department of Radiation Oncology UT Southwestern Medical Center Dallas, TX September 1 st, 2012 CMPWG Workshop Medical
More informationRaising the Bar in IMRT QA
MapCHECK 2TM Raising the Bar in IMRT QA The leader in quick and precise measurement of modulated radiotherapy beams Benefits Proven solution for film-less rotational delivery and IMRT QA - More than 1500
More information8/4/2016. Emerging Linac based SRS/SBRT Technologies with Modulated Arc Delivery. Disclosure. Introduction: Treatment delivery techniques
Emerging Linac based SRS/SBRT Technologies with Modulated Arc Delivery Lei Ren, Ph.D. Duke University Medical Center 2016 AAPM 58 th annual meeting, Educational Course, Therapy Track Disclosure I have
More informationGoals. Scope/exclusions. Outline: follow outline of MPPG (plus rationale & some implementation experiences)
AAPM MEDICAL PHYSICS PRACTICE GUIDELINE # : Commissioning and QA of Treatment Planning Dose Calculations: Megavoltage Photon and Electron Beams Jennifer Smilowitz (Chair), University of Wisconsin-Madison
More informationThe MSKCC Approach to IMRT. Outline
The MSKCC Approach to IMRT Spiridon V. Spirou, PhD Department of Medical Physics Memorial Sloan-Kettering Cancer Center New York, NY Outline Optimization Field splitting Delivery Independent verification
More informationAn Analytic Linear Accelerator Source Model for Monte Carlo Dose Calculations. I. Model Representation and Construction
An Analytic Linear Accelerator Source Model for Monte Carlo Dose Calculations. I. Model Representation and Construction Zhen Tian 1, Yongbao Li 1,2, Michael Folkerts 1, Feng Shi 1, Steve B. Jiang 1, Xun
More informationVerification of dose calculations with a clinical treatment planning system based on a point kernel dose engine
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, VOLUME 3, NUMBER 2, SPRING 2002 Verification of dose calculations with a clinical treatment planning system based on a point kernel dose engine Lars Weber*
More informationComputational modelling and analysis: IOP Medical Physics Group
Computational modelling and analysis: IOP Medical Physics Group Using Bespoke Matlab Software for the Collection and Processing of Dynalog Files from the Varian Millennium 120 MLC system following delivery
More informationQalitätssicherung an Multileafkollimatoren. Dr. Lutz Müller Würzburg jan 2004
Qalitätssicherung an Multileafkollimatoren Dr. Lutz Müller Würzburg jan 2004 IMRT Verification - present Target Volume Constraints Inverse Planning Algorithm Fluence Map Leaf Sequencer Leaf & Gantry sequence
More informationCBCT Equivalent Source Generation Using HVL and Beam Profile Measurements. Johnny Little PSM - Medical Physics Graduate Student University of Arizona
CBCT Equivalent Source Generation Using HVL and Beam Profile Measurements. Johnny Little PSM - Medical Physics Graduate Student University of Arizona Introduction CBCT has become a routine procedure for
More informationReal-time monitoring of linac performance using RT plans and logfiles
Real-time monitoring of linac performance using RT plans and logfiles NCCAAPM Wisconsin Dells 7 April 2017 Mark Wiesmeyer, PhD, DABR Technical Product Manager Technical talk with insights and results based
More informationVolumetric Modulated Arc Therapy - Clinical Implementation. Outline. Acknowledgement. History of VMAT. IMAT Basics of IMAT
Volumetric Modulated Arc Therapy - Clinical Implementation Daliang Cao, PhD, DABR Swedish Cancer Institute, Seattle, WA Acknowledgement David M. Shepard, Ph.D. Muhammad K. N. Afghan, Ph.D. Fan Chen, Ph.D.
More informationThe importance of accurate linear accelerator head modelling for IMRT Monte Carlo
Home Search Collections Journals About Contact us My IOPscience The importance of accurate linear accelerator head modelling for IMRT Monte Carlo calculations This article has been downloaded from IOPscience.
More information2D DOSE MEASUREMENT USING A FLAT PANEL EPID
2D DOSE MEASUREMENT USING A FLAT PANEL EPID by Seng Boh Lim B.A.Sc. (Hons.), University of British Columbia, 1994 M.A.Sc., University of British Colombia, 1996 M.Eng, University of British Columbia, 2002
More informationSuggesting a new design for multileaf collimator leaves based on Monte Carlo simulation of two commercial systems
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, VOLUME 11, NUMBER 3, Summer 2010 Suggesting a new design for multileaf collimator leaves based on Monte Carlo simulation of two commercial systems Sanaz Hariri,
More informationCalibration and quality assurance for rounded leaf-end MLC systems
Calibration and quality assurance for rounded leaf-end MLC systems Maria N. Graves, a) Antoinette V. Thompson, b) Mary K. Martel, Daniel L. McShan, and Benedick A. Fraass Department of Radiation Oncology,
More informationInvestigation of photon beam output factors for conformal radiation therapy Monte Carlo simulations and measurements
INSTITUTE OF PHYSICSPUBLISHING Phys. Med. Biol. 47 (2002) N133 N143 PHYSICS INMEDICINE AND BIOLOGY PII: S0031-9155(02)32395-9 NOTE Investigation of photon beam output factors for conformal radiation therapy
More informationMPEXS benchmark results
MPEXS benchmark results - phase space data - Akinori Kimura 14 February 2017 Aim To validate results of MPEXS with phase space data by comparing with Geant4 results Depth dose and lateral dose distributions
More informationI. INTRODUCTION. Figure 1. Radiation room model at Dongnai General Hospital
International Journal of Computational Engineering Research Vol, 04 Issue, 4 Simulation of Photon and Electron dose distributions 5 code for the treatment area using the linear electron accelerator (LINAC)
More informationShielding factors for traditional safety glasses
Shielding factors for traditional safety glasses Malcolm McEwen, Hong Shen and Ernesto Mainegra-Hing Ionizing Radiation Standards, National Research Council Canada Alan DuSautoy, Radiation and Health Sciences
More informationPhoton beam dose distributions in 2D
Photon beam dose distributions in 2D Sastry Vedam PhD DABR Introduction to Medical Physics III: Therapy Spring 2014 Acknowledgments! Narayan Sahoo PhD! Richard G Lane (Late) PhD 1 Overview! Evaluation
More informationComprehensive evaluation and clinical implementation of commercially available Monte Carlo dose calculation algorithm
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, VOLUME 14, NUMBER 2, 2013 Comprehensive evaluation and clinical implementation of commercially available Monte Carlo dose calculation algorithm Aizhen Zhang,
More informationValidation of GEANT4 for Accurate Modeling of 111 In SPECT Acquisition
Validation of GEANT4 for Accurate Modeling of 111 In SPECT Acquisition Bernd Schweizer, Andreas Goedicke Philips Technology Research Laboratories, Aachen, Germany bernd.schweizer@philips.com Abstract.
More informationUsing a research real-time control interface to go beyond dynamic MLC tracking
in partnership with Using a research real-time control interface to go beyond dynamic MLC tracking Dr. Simeon Nill Joint Department of Physics at The Institute of Cancer Research and the Royal Marsden
More informationICARO Vienna April Implementing 3D conformal radiotherapy and IMRT in clinical practice: Recommendations of IAEA- TECDOC-1588
ICARO Vienna April 27-29 2009 Implementing 3D conformal radiotherapy and IMRT in clinical practice: Recommendations of IAEA- TECDOC-1588 M. Saiful Huq, Ph.D., Professor and Director, Dept. of Radiation
More informationImplementation of Monte Carlo Dose calculation for CyberKnife treatment planning
Journal of Physics: Conference Series Implementation of Monte Carlo Dose calculation for CyberKnife treatment planning To cite this article: C-M Ma et al 2008 J. Phys.: Conf. Ser. 102 012016 View the article
More informationAcknowledgments. Ping Xia, Ph.D., UCSF. Pam Akazawa, CMD, UCSF. Cynthia Chuang, Ph.D., UCSF
Page 1 Quality Assurance of IMRT Delivery Systems - Siemens Lynn J. Verhey, Ph.D. Professor and Vice-Chair UCSF Dept. of Radiation Oncology AAPM 22 Annual Meeting, Montreal Acknowledgments Ping Xia, Ph.D.,
More informationDisclosure. Outline. Acknowledgments. Ping Xia, Ph.D., Page 1. LINAC and MLC QA for IMRT. Received research support from Siemens Medical Solutions
LINAC and MLC QA for IMRT Ping Xia, Ph.D., Department of Radiation Oncology Disclosure Received research support from Siemens Medical Solutions University of California San Francisco Therapy Series (SAM)
More informationState-of-the-Art IGRT
in partnership with State-of-the-Art IGRT Exploring the Potential of High-Precision Dose Delivery and Real-Time Knowledge of the Target Volume Location Antje-Christin Knopf IOP Medical Physics Group Scientific
More informationUNIVERSITY OF CALGARY. Monte Carlo model of the Brainlab Novalis Classic 6 MV linac using the GATE simulation. platform. Jared K.
UNIVERSITY OF CALGARY Monte Carlo model of the Brainlab Novalis Classic 6 MV linac using the GATE simulation platform by Jared K. Wiebe A THESIS SUBMITTED TO THE FACULTY OF GRADUATE STUDIES IN PARTIAL
More informationCreating a Knowledge Based Model using RapidPlan TM : The Henry Ford Experience
DVH Estimates Creating a Knowledge Based Model using RapidPlan TM : The Henry Ford Experience Karen Chin Snyder, MS, DABR AAMD Region V Meeting October 4, 2014 Disclosures The Department of Radiation Oncology
More informationImage-based Monte Carlo calculations for dosimetry
Image-based Monte Carlo calculations for dosimetry Irène Buvat Imagerie et Modélisation en Neurobiologie et Cancérologie UMR 8165 CNRS Universités Paris 7 et Paris 11 Orsay, France buvat@imnc.in2p3.fr
More information8/2/2017. PerFRACTION from Sun Nuclear Automated Transit Dosimetry for In-Vivo QA
PerFRACTION from Sun Nuclear Automated Transit Dosimetry for In-Vivo QA Jennifer R. Clark, M.S., DABR Conflict of Interest Statement: I am an employee of Sun Nuclear Corporation Outline: Platform overview
More informationJOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, VOLUME 15, NUMBER 1, 2014
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, VOLUME 15, NUMBER 1, 2014 Measurement and Monte Carlo simulation for energy- and intensity-modulated electron radiotherapy delivered by a computer-controlled
More informationADVANCING CANCER TREATMENT
3 ADVANCING CANCER TREATMENT SUPPORTING CLINICS WORLDWIDE RaySearch is advancing cancer treatment through pioneering software. We believe software has un limited potential, and that it is now the driving
More informationMonaco VMAT. The Next Generation in IMRT/VMAT Planning. Paulo Mathias Customer Support TPS Application
Monaco VMAT The Next Generation in IMRT/VMAT Planning Paulo Mathias Customer Support TPS Application 11.05.2011 Background What is Monaco? Advanced IMRT/VMAT treatment planning system from Elekta Software
More informationHidenobu Tachibana The Cancer Institute Hospital of JFCR, Radiology Dept. The Cancer Institute of JFCR, Physics Dept.
2-D D Dose-CT Mapping in Geant4 Hidenobu Tachibana The Cancer Institute Hospital of JFCR, Radiology Dept. The Cancer Institute of JFCR, Physics Dept. Table of Contents Background & Purpose Materials Methods
More informationA fluence convolution method to account for respiratory motion in three-dimensional dose calculations of the liver: A Monte Carlo study
A fluence convolution method to account for respiratory motion in three-dimensional dose calculations of the liver: A Monte Carlo study Indrin J. Chetty, a) Mihaela Rosu, Neelam Tyagi, Lon H. Marsh, Daniel
More information