Chapter 32 3-D and 4-D imaging in Obstetrics and Gynecology
|
|
- Anastasia Lang
- 6 years ago
- Views:
Transcription
1 Objectives Define common terms related to 3D/4D ultrasound Chapter 32 3-D and 4-D imaging in Obstetrics and Gynecology Bridgette Lunsford Describe how 3D and 4D imaging differs from 2D ultrasound Identify the advantages and disadvantages of 3D/4D ultrasound List the benefits and drawbacks of the three acquisition techniques Recall 3D volume data set manipulation through use of the MPR format Objectives-continued List the advantages of using the MPR format Describe tomographic or multislice ultrasound imaging and list the benefits of this viewing format Explain common rendering modes and the clinical application of each Define VOCAL listing potential clinical applications in both OB and GYN imaging Describe common clinical applications for 3D ultrasound in obstetric and gynecological imaging Identify the concerns surrounding keepsake imaging and describe the current position of the ultrasound community What is Volume Ultrasound? Series of 2D images Includes 3D and 4D Image composition Pixel Voxel Limitations of 3D/4D Ultrasound What is Volume Ultrasound? 1
2 Benefits of 3D/4D Ultrasound Acquisition Techniques - Freehand Acquisition Techniques Sensor-based Acquisition Techniques - Mechanical Acquisition Techniques - Matrix Obtaining a 3D Volume Region of Interest (ROI) 2D - X and Y axis 3D Z axis 2
3 Obtaining a 3D Volume Obtaining a 3D Volume Acquisition speed Slow More slices Higher quality Larger volume size Fast Eliminates motion artifacts Obtaining a 3D Volume 3D Mulitplanar Reconstruction Most common display format Displays three orthogonal planes and the rendered volume. Orthogonal planes always 90 degrees to each other Planes A = acquisition plane B = orthogonal to A and C C = orthogonal to A and B 3D Mulitplanar Reconstruction 3D Mulitplanar Reconstruction 3
4 3D Mulitplanar Reconstruction Able to rotate data to create images on any plane Rotations X Y Z All plains remain orthogonal even during rotations Virtual re-scan 3D Mulitplanar Reconstruction C-plane Aka Z-plane Plane only acquired with a 3D data set Tomographic Ultrasound Imaging Tomographic Ultrasound Imaging Display of serial parallel images Similar to MRI or CT display Available with color Doppler modes Allows imaging for different anatomy Surface Threshold Eraser or scalpel Maximum, skeletal, or x-ray Inversion Glass body or transparency Virtual Organ Computer Aided Analysis (VOCAL) 4
5 5
6 Virtual Organ Computer Aided Analysis or VOCAL Calculates the volume of an irregular object 3D model 3D versus 4D 3D Static image 4D Live or real-time image Mullerian duct anomailes Bicornuate vs. septate uterus Uterine contour Sonohystogram IUD location Essure coils tubal occlusion Tumor Doppler indices 6
7 7
8 Artifacts Same as seen with 2D Display on three planes often confusing 8
9 9
10 Spatio-temporal image correlation (STIC) Method to image the fetal heart 4D sequence of images obtaining both time and space Results in a real-time motion-gated image acquisition 10
11 Ethical Considerations/Parental Bonding The American Institute of Ultrasound in Medicine (AIUM) states, the AIUM advocates the responsible use of diagnostic ultrasound for all fetal imaging. The AIUM and the FDA both discourage the use of ultrasound for reasons not medically indicated Use of the Data set after Acquisition Data manipulation On machine Offline vendor specific software Currently no Digital Imaging and Communications in Medicine (DICOM) standard for 3D/4D data 11
Mohammad Baharvandy & Sina Fazelpour
Mohammad Baharvandy & Sina Fazelpour Ultrasound Basics Data acquisition in 3D Reconstruction of 2D images 3D Ultrasound Modeling Medical applications 4D Ultrasound 2 Ultrasound consist of sound waves of
More informationDigital Image Processing
Digital Image Processing SPECIAL TOPICS CT IMAGES Hamid R. Rabiee Fall 2015 What is an image? 2 Are images only about visual concepts? We ve already seen that there are other kinds of image. In this lecture
More informationThe Supreme 3D/4D Ultrasound. The Supreme 3D/4D Ultrasound. CT-V20-ICM
The Supreme 3D/4D Ultrasound The Supreme 3D/4D Ultrasound www.medison.com info@medison.com CT-V20-ICM-06.20.2008 The Supreme 3D/4D Ultrasound Since launching the first commercially available 3D ultrasound
More informationImage Acquisition Systems
Image Acquisition Systems Goals and Terminology Conventional Radiography Axial Tomography Computer Axial Tomography (CAT) Magnetic Resonance Imaging (MRI) PET, SPECT Ultrasound Microscopy Imaging ITCS
More informationA Study of Medical Image Analysis System
Indian Journal of Science and Technology, Vol 8(25), DOI: 10.17485/ijst/2015/v8i25/80492, October 2015 ISSN (Print) : 0974-6846 ISSN (Online) : 0974-5645 A Study of Medical Image Analysis System Kim Tae-Eun
More information3D Echocardiography Development Timeline
3D Acquisition Strategies and Display Lissa Sugeng, MD, MPH Associate Professor of Medicine Director of the Yale Echo Lab and Echo Core Lab (YCRG) And Peter Flueckiger, MD Advanced Imaging Cardiology Fellow
More informationClinical Importance. Aortic Stenosis. Aortic Regurgitation. Ultrasound vs. MRI. Carotid Artery Stenosis
Clinical Importance Rapid cardiovascular flow quantitation using sliceselective Fourier velocity encoding with spiral readouts Valve disease affects 10% of patients with heart disease in the U.S. Most
More informationLecture 6: Medical imaging and image-guided interventions
ME 328: Medical Robotics Winter 2019 Lecture 6: Medical imaging and image-guided interventions Allison Okamura Stanford University Updates Assignment 3 Due this Thursday, Jan. 31 Note that this assignment
More informationUltrasound. Q-Station software. Streamlined workflow solutions. Philips Q-Station ultrasound workspace software
Ultrasound Q-Station software Streamlined workflow solutions Philips Q-Station ultrasound workspace software Managing your off-cart workf low Everyone is being asked to do more with fewer resources it
More informationComputational Medical Imaging Analysis Chapter 4: Image Visualization
Computational Medical Imaging Analysis Chapter 4: Image Visualization Jun Zhang Laboratory for Computational Medical Imaging & Data Analysis Department of Computer Science University of Kentucky Lexington,
More informationIMPAX Volume Viewing 3D Visualization & Segmentation
Getting started guide IMPAX Volume Viewing 3D Visualization & Segmentation This guide outlines the basic steps to perform and manipulate a 3D reconstruction of volumetric image data using IMPAX Volume
More informationMedical Image Analysis
Computer assisted Image Analysis VT04 29 april 2004 Medical Image Analysis Lecture 10 (part 1) Xavier Tizon Medical Image Processing Medical imaging modalities XRay,, CT Ultrasound MRI PET, SPECT Generic
More informationREAL-TIME ADAPTIVITY IN HEAD-AND-NECK AND LUNG CANCER RADIOTHERAPY IN A GPU ENVIRONMENT
REAL-TIME ADAPTIVITY IN HEAD-AND-NECK AND LUNG CANCER RADIOTHERAPY IN A GPU ENVIRONMENT Anand P Santhanam Assistant Professor, Department of Radiation Oncology OUTLINE Adaptive radiotherapy for head and
More informationBasic principles of MR image analysis. Basic principles of MR image analysis. Basic principles of MR image analysis
Basic principles of MR image analysis Basic principles of MR image analysis Julien Milles Leiden University Medical Center Terminology of fmri Brain extraction Registration Linear registration Non-linear
More informationRole of Parallel Imaging in High Field Functional MRI
Role of Parallel Imaging in High Field Functional MRI Douglas C. Noll & Bradley P. Sutton Department of Biomedical Engineering, University of Michigan Supported by NIH Grant DA15410 & The Whitaker Foundation
More informationMulti-slice CT Image Reconstruction Jiang Hsieh, Ph.D.
Multi-slice CT Image Reconstruction Jiang Hsieh, Ph.D. Applied Science Laboratory, GE Healthcare Technologies 1 Image Generation Reconstruction of images from projections. textbook reconstruction advanced
More informationUltrasound To Go. MySono U5
Ultrasound To Go MySono U5 Ultrasound To Go With the introduction of the MySono U5, Samsung Medison brings you a fully featured ultrasound imaging system to go. Delivering exceptional image quality and
More informationBrilliance CT Big Bore.
1 2 2 There are two methods of RCCT acquisition in widespread clinical use: cine axial and helical. In RCCT with cine axial acquisition, repeat CT images are taken each couch position while recording respiration.
More informationINTRODUCTION TO MEDICAL IMAGING- 3D LOCALIZATION LAB MANUAL 1. Modifications for P551 Fall 2013 Medical Physics Laboratory
INTRODUCTION TO MEDICAL IMAGING- 3D LOCALIZATION LAB MANUAL 1 Modifications for P551 Fall 2013 Medical Physics Laboratory Introduction Following the introductory lab 0, this lab exercise the student through
More informationNON OB ULTRASOUND MORPHOMETRICS AS BIOMARKERS
NON OB ULTRASOUND MORPHOMETRICS AS BIOMARKERS Brian S Garra Washington DC VA Medical Center and Division of Imaging & Applied Mathematics, OSEL, CDRH, FDA GOALS Review Major Types of Clinical Ultrasonic
More informationUltrasound To Go. The MySono U5 -
Ultrasound To Go The MySono U5 - Ultrasound To Go With the introduction of the MySono U5, MEDISON brings you a fully featured ultrasound imaging system to go. Delivering exceptional image quality and featuring
More informationVieW 3D. 3D Post-Processing WorKstation THE THIRD DIMENSION. Version 3.1
VieW 3D 3D Post-Processing WorKstation THE THIRD DIMENSION Version 3.1 iq-view 3D THE FULLY-FEATURED 3D MEDICAL IMAGING SOLUTION FOR RADIOLOGISTS iq-view 3D contains all components of iq-view with the
More informationScalar Data. Visualization Torsten Möller. Weiskopf/Machiraju/Möller
Scalar Data Visualization Torsten Möller Weiskopf/Machiraju/Möller Overview Basic strategies Function plots and height fields Isolines Color coding Volume visualization (overview) Classification Segmentation
More informationFocus on your needs. Ultrasound system HS60 SAMSUNG MEDISON CO., LTD. CT-HS60 V1.0-OB-FT EN
Samsung Medison, an affiliate of Samsung Electronics, is a global medical company founded in 1985. With a mission to bring health and well-being to people's lives, the company manufactures diagnostic ultrasound
More informationDiagnostic Ultrasound System. Operation Manual. Version English MI A
Diagnostic Ultrasound System Operation Manual Version 1.00.00 English MI68-02334A Table of Contents Table of Contents Volume 2 Chapter 6 Starting Diagnosis System Power... 6-3 Turning the Power On...
More informationScalar Data. CMPT 467/767 Visualization Torsten Möller. Weiskopf/Machiraju/Möller
Scalar Data CMPT 467/767 Visualization Torsten Möller Weiskopf/Machiraju/Möller Overview Basic strategies Function plots and height fields Isolines Color coding Volume visualization (overview) Classification
More informationLeading the New Standards
Samsung Medison is a global leading medical devices company. Founded in 1985, the company now sells cutting-edge medical devices including diagnostic ultrasound, digital X-ray and blood analyzer, in 110
More informationTomographic Reconstruction
Tomographic Reconstruction 3D Image Processing Torsten Möller Reading Gonzales + Woods, Chapter 5.11 2 Overview Physics History Reconstruction basic idea Radon transform Fourier-Slice theorem (Parallel-beam)
More informationicatvision Quick Reference
icatvision Quick Reference Navigating the i-cat Interface This guide shows how to: View reconstructed images Use main features and tools to optimize an image. REMINDER Images are displayed as if you are
More informationProcess to Convert DICOM Data to 3D Printable STL Files
HOW-TO GUIDE Process to Convert DICOM Data to 3D Printable STL Files Mac Cameron, Application Engineer Anatomical models have several applications in the medical space from patient-specific models used
More informationTechnical Publications
g GE Medical Systems Technical Publications 2365523-100 Revision 1 DICOM for DICOM V3.0 Copyright 2003 By General Electric Co. Do not duplicate REVISION HISTORY REV DATE REASON FOR CHANGE 0 Nov. 15, 2002
More informationVolume Ultrasound, rendering modes and clinical application
GE Healthcare Volume Ultrasound, rendering modes and clinical application R. CHAOUI Center for Prenatal Diagnosis and Human Genetics, Berlin, Germany B. BENOIT Hospital Princesse Grace, Monaco, Monte Carlo
More informationUNIVERSITY OF SOUTHAMPTON
UNIVERSITY OF SOUTHAMPTON PHYS2007W1 SEMESTER 2 EXAMINATION 2014-2015 MEDICAL PHYSICS Duration: 120 MINS (2 hours) This paper contains 10 questions. Answer all questions in Section A and only two questions
More informationMEDICAL IMAGING 2nd Part Computed Tomography
MEDICAL IMAGING 2nd Part Computed Tomography Introduction 2 In the last 30 years X-ray Computed Tomography development produced a great change in the role of diagnostic imaging in medicine. In convetional
More informationDigital Imaging and Communications in Medicine (DICOM) Supplement 167: X-Ray 3D Angiographic IOD Informative Annex
5 Digital Imaging and Communications in Medicine (DICOM) Supplement 167: X-Ray 3D Angiographic IOD Informative Annex 10 15 Prepared by: DICOM Standards Committee, Working Group 2, Projection Radiography
More informationUGEO G60 Performance in style
CT-UGEO-G60-CWW-MCI-0731-EN Performance in style 2012 Samsung Electronics All Rights Reserved. Samsung Electronics Reserves The Right To Modify The Design, Packaging, Specifications And Features Shown
More informationCorso di laurea in Fisica A.A Fisica Medica 4 TC
Corso di laurea in Fisica A.A. 2007-2008 Fisica Medica 4 TC Computed Tomography Principles 1. Projection measurement 2. Scanner systems 3. Scanning modes Basic Tomographic Principle The internal structure
More informationRespiratory Motion Estimation using a 3D Diaphragm Model
Respiratory Motion Estimation using a 3D Diaphragm Model Marco Bögel 1,2, Christian Riess 1,2, Andreas Maier 1, Joachim Hornegger 1, Rebecca Fahrig 2 1 Pattern Recognition Lab, FAU Erlangen-Nürnberg 2
More informationMedical Image Processing: Image Reconstruction and 3D Renderings
Medical Image Processing: Image Reconstruction and 3D Renderings 김보형 서울대학교컴퓨터공학부 Computer Graphics and Image Processing Lab. 2011. 3. 23 1 Computer Graphics & Image Processing Computer Graphics : Create,
More informationTissue Doppler gated (TDOG) dynamic three-dimensional ultrasound imaging of the fetal heart
Ultrasound Obstet Gynecol 2004; 24: 192 198 Published online in Wiley InterScience (www.interscience.wiley.com). DOI: 10.1002/uog.1094 Tissue Doppler gated (TDOG) dynamic three-dimensional ultrasound imaging
More informationComputed tomography of simple objects. Related topics. Principle. Equipment TEP Beam hardening, artefacts, and algorithms
Related topics Beam hardening, artefacts, and algorithms Principle The CT principle is demonstrated with the aid of simple objects. In the case of very simple targets, only a few images need to be taken
More informationGPU Ultrasound Simulation and Volume Reconstruction
GPU Ultrasound Simulation and Volume Reconstruction Athanasios Karamalis 1,2 Supervisor: Nassir Navab1 Advisor: Oliver Kutter1, Wolfgang Wein2 1Computer Aided Medical Procedures (CAMP), Technische Universität
More informationComputational Medical Imaging Analysis
Computational Medical Imaging Analysis Chapter 1: Introduction to Imaging Science Jun Zhang Laboratory for Computational Medical Imaging & Data Analysis Department of Computer Science University of Kentucky
More informationDisplay. Introduction page 67 2D Images page 68. All Orientations page 69 Single Image page 70 3D Images page 71
Display Introduction page 67 2D Images page 68 All Orientations page 69 Single Image page 70 3D Images page 71 Intersecting Sections page 71 Cube Sections page 72 Render page 73 1. Tissue Maps page 77
More informationImage Guidance and Beam Level Imaging in Digital Linacs
Image Guidance and Beam Level Imaging in Digital Linacs Ruijiang Li, Ph.D. Department of Radiation Oncology Stanford University School of Medicine 2014 AAPM Therapy Educational Course Disclosure Research
More informationLOGIQ. V2 Ultrasound. Part of LOGIQ Vision Series. Imagination at work LOGIQ is a trademark of General Electric Company.
TM LOGIQ V2 Ultrasound Part of LOGIQ Vision Series Imagination at work The brilliance of color. The simplicity of GE. Now you can add the advanced capabilities of color Doppler to patient care with the
More informationFluorescence Tomography Source Reconstruction and Analysis
TECHNICAL NOTE Pre-clinical in vivo imaging Fluorescence Tomography Source Reconstruction and Analysis Note: This Technical Note is part of a series for Fluorescence Imaging Tomography (FLIT). The user
More informationMotion Compensation from Short-Scan Data in Cardiac CT
Motion Compensation from Short-Scan Data in Cardiac CT Juliane Hahn 1,2, Thomas Allmendinger 1, Herbert Bruder 1, and Marc Kachelrieß 2 1 Siemens Healthcare GmbH, Forchheim, Germany 2 German Cancer Research
More informationVisualisation : Lecture 1. So what is visualisation? Visualisation
So what is visualisation? UG4 / M.Sc. Course 2006 toby.breckon@ed.ac.uk Computer Vision Lab. Institute for Perception, Action & Behaviour Introducing 1 Application of interactive 3D computer graphics to
More informationOptimization of CT Simulation Imaging. Ingrid Reiser Dept. of Radiology The University of Chicago
Optimization of CT Simulation Imaging Ingrid Reiser Dept. of Radiology The University of Chicago Optimization of CT imaging Goal: Achieve image quality that allows to perform the task at hand (diagnostic
More information3D XI. Multi-Slice View. Oblique View. Demo és second hand ultrahang-diagnosztikai berendezések a honlapon!
SONARMED Kereskedelmi és Egészségügyi Szolgáltató Kft. Tel.: +36 1 203 75 81 1119 Budapest, Nándorfejérvári út 31. fsz. 6-7. +36 20 982 63 11 / 12 info@sonarmed.hu Fax: +36 1 205 39 59 3D XI 3D extended
More informationAn investigation of temporal resolution parameters in cine-mode four-dimensional computed tomography acquisition
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, VOLUME 9, NUMBER 4, FALL 2008 An investigation of temporal resolution parameters in cine-mode four-dimensional computed tomography acquisition Yildirim D. Mutaf
More informationThE ultimate, INTuITIVE Mr INTErFAcE
ThE ultimate, INTuITIVE Mr INTErFAcE Empowering you to do more The revolutionary Toshiba M-power user interface takes Mr performance and flexibility to levels higher than ever before. M-power is able to
More informationCh. 4 Physical Principles of CT
Ch. 4 Physical Principles of CT CLRS 408: Intro to CT Department of Radiation Sciences Review: Why CT? Solution for radiography/tomography limitations Superimposition of structures Distinguishing between
More informationComputed tomography (Item No.: P )
Computed tomography (Item No.: P2550100) Curricular Relevance Area of Expertise: Biology Education Level: University Topic: Modern Imaging Methods Subtopic: X-ray Imaging Experiment: Computed tomography
More information19 CP Replace uses of "data set" that do not refer to the PS3.5 defined meaning
19 CP-1817 - Replace uses of "data set" that do not refer to the PS3.5 defined meaning Page 1 1 Status Assigned 2 Date of Last Update 2018/06/04 3 Person Assigned David Clunie 4 mailto:dclunie@dclunie.com
More informationImprove your image. ClearVue 550 ultrasound system
Improve your image ClearVue 550 ultrasound system Smart and intuitive One look at the Philips ClearVue 550 ultrasound system and you ll see the smooth, graceful lines and elegant design that show this
More informationSlide 1. Technical Aspects of Quality Control in Magnetic Resonance Imaging. Slide 2. Annual Compliance Testing. of MRI Systems.
Slide 1 Technical Aspects of Quality Control in Magnetic Resonance Imaging Slide 2 Compliance Testing of MRI Systems, Ph.D. Department of Radiology Henry Ford Hospital, Detroit, MI Slide 3 Compliance Testing
More informationTechnical Publications
g GE Medical Systems Technical Publications Direction 2264272-100 Revision 1 DICOM for DICOM V3.0 Copyright ª 2000 By General Electric Co. Do not duplicate THIS PAGE LEFT INTENTIONALLY BLANK TABLE OF
More informationThree-dimensional graphics system of medical images on the Web for patients
Three-dimensional graphics system of medical images on the Web for patients Koji Kobayashi *1, Koichi Ito *2, Takafumi Aoki *2 *1 Vocsis Corporation *2 Graduate School of Information Sciences, Tohoku University
More informationTechnical Publications
GE Medical Systems Technical Publications Direction 2290660-100 Revision A DICOM for DICOM V3.0 Copyright ª 2001 By General Electric Co. Do not duplicate NETWORK CONFORMANCE STATEMENT CT INFORMATION OBJECT
More informationSimplicity, quality, and flexibility
Ultrasound Lumify Simplicity, quality, and flexibility Philips Lumify ultrasound system specifications Contents 1 Introduction 3 1.1 Applications 3 2 System overview 4 2.1 System architecture 4 2.2 Imaging
More informationVoxar 3D ColonMetrix. Reference Guide
Voxar 3D ColonMetrix Reference Guide The software described in this document is furnished under a license, and may be used or copied only according to the terms of such license. Toshiba means, Toshiba
More informationFOREWORD TO THE SPECIAL ISSUE ON MOTION DETECTION AND COMPENSATION
Philips J. Res. 51 (1998) 197-201 FOREWORD TO THE SPECIAL ISSUE ON MOTION DETECTION AND COMPENSATION This special issue of Philips Journalof Research includes a number of papers presented at a Philips
More informationDeviceless respiratory motion correction in PET imaging exploring the potential of novel data driven strategies
g Deviceless respiratory motion correction in PET imaging exploring the potential of novel data driven strategies Presented by Adam Kesner, Ph.D., DABR Assistant Professor, Division of Radiological Sciences,
More informationThis is your imaging dashboard. There is a bevy of valuable information to read from here. Let s break it up.
The Volume Strikes Back Press the (4D) button. This is your imaging dashboard. There is a bevy of valuable information to read from here. Let s break it up. In the Left GUI (Graphic User Interface), you
More informationRefraction Corrected Transmission Ultrasound Computed Tomography for Application in Breast Imaging
Refraction Corrected Transmission Ultrasound Computed Tomography for Application in Breast Imaging Joint Research With Trond Varslot Marcel Jackowski Shengying Li and Klaus Mueller Ultrasound Detection
More informationCT NOISE POWER SPECTRUM FOR FILTERED BACKPROJECTION AND ITERATIVE RECONSTRUCTION
CT NOISE POWER SPECTRUM FOR FILTERED BACKPROJECTION AND ITERATIVE RECONSTRUCTION Frank Dong, PhD, DABR Diagnostic Physicist, Imaging Institute Cleveland Clinic Foundation and Associate Professor of Radiology
More informationReal-Time Data Acquisition for Cardiovascular Research
Real-Time Data Acquisition for Cardiovascular Research Andras Lasso, PhD Laboratory for Percutaneous Surgery School of Computing, Queen s University, Kingston Questions / challenges What hardware/software
More informationMachine Learning for Medical Image Analysis. A. Criminisi
Machine Learning for Medical Image Analysis A. Criminisi Overview Introduction to machine learning Decision forests Applications in medical image analysis Anatomy localization in CT Scans Spine Detection
More informationA Slim and Ultra Compact System, With Advanced Performance
Samsung Medison is a global leading medical devices company. Founded in 1985, the company now sells cutting-edge medical devices including diagnostic ultrasound, digital X-ray and blood analyzer, in 110
More informationBackground. Outline. Radiographic Tomosynthesis: Image Quality and Artifacts Reduction 1 / GE /
Radiographic Tomosynthesis: Image Quality and Artifacts Reduction Baojun Li, Ph.D Department of Radiology Boston University Medical Center 2012 AAPM Annual Meeting Background Linear Trajectory Tomosynthesis
More informationUS 1.
US 1 Sample image: Normal pancreas seen on sonogram. Looking up from abdomen toward the head of the patient. The liver is in front of the pancreas. A vein draining the spleen is behind the pancreas http://www.radiologyinfo.org/photocat/photos.cfm?image=abdo-us-pancr.jpg&&subcategory=abdomen&&stop=9
More informationAPLIO JUST GOT EVEN BETTER INTRODUCING THE INNOVATION 2016 UPGRADE
APLIO JUST GOT EVEN BETTER INTRODUCING THE INNOVATION 2016 UPGRADE INNOVATION 2016 AT A GLANCE More clinical detail New settings in the Precision technology package provide enhanced border delineation
More informationCLASS HOURS: 4 CREDIT HOURS: 4 LABORATORY HOURS: 0
Revised 10/10 COURSE SYLLABUS TM 220 COMPUTED TOMOGRAPHY PHYSICS CLASS HOURS: 4 CREDIT HOURS: 4 LABORATORY HOURS: 0 CATALOG COURSE DESCRIPTION: This course is one of a three course set in whole body Computed
More informationA Temporal Image-Based Approach to Motion Reconstruction for Globally Illuminated Animated Environments
University of Pennsylvania ScholarlyCommons Center for Human Modeling and Simulation Department of Computer & Information Science June 1996 A Temporal Image-Based Approach to Motion Reconstruction for
More informationRADIOLOGY AND DIAGNOSTIC IMAGING
Day 2 part 2 RADIOLOGY AND DIAGNOSTIC IMAGING Dr hab. Zbigniew Serafin, MD, PhD serafin@cm.umk.pl 2 3 4 5 CT technique CT technique 6 CT system Kanal K: RSNA/AAPM web module: CT Systems & CT Image Quality
More informationCopyright 2017 Medical IP - Tutorial Medip v /2018, Revision
Copyright 2017 Medical IP - Tutorial Medip v.1.0.0.9 01/2018, Revision 1.0.0.2 List of Contents 1. Introduction......................................................... 2 2. Overview..............................................................
More informationA Navigation System for Minimally Invasive Abdominal Intervention Surgery Robot
A Navigation System for Minimally Invasive Abdominal Intervention Surgery Robot Weiming ZHAI, Yannan ZHAO and Peifa JIA State Key Laboratory of Intelligent Technology and Systems Tsinghua National Laboratory
More informationAnnexure XII SPECIFICATIONS FOR A NEW STATE OF ART 16 SLICE ALL PURPOSE C. T. SCANNER
Annexure XII SPECIFICATIONS FOR A NEW STATE OF ART 16 SLICE ALL PURPOSE C. T. SCANNER A) Scanner Design X-Ray generator and tube: 1. Scanner: Whole body spiral CT scanner (16 slices) of latest technology.
More information8/7/2017. Disclosures. MECT Systems Overview and Quantitative Opportunities. Overview. Computed Tomography (CT) CT Numbers. Polyenergetic Acquisition
Quantitative Multi-Energy Computed Tomography: Imaging and Therapy Advancements Disclosures MECT Systems Overview and Quantitative Opportunities The speaker receives research funding from GE Healthcare
More informationCT Basics Principles of Spiral CT Dose. Always Thinking Ahead.
1 CT Basics Principles of Spiral CT Dose 2 Who invented CT? 1963 - Alan Cormack developed a mathematical method of reconstructing images from x-ray projections Sir Godfrey Hounsfield worked for the Central
More informationUse of MRI in Radiotherapy: Technical Consideration
Use of MRI in Radiotherapy: Technical Consideration Yanle Hu, PhD Department of Radiation Oncology, Mayo Clinic Arizona 04/07/2018 2015 MFMER slide-1 Conflict of Interest: None 2015 MFMER slide-2 Objectives
More informationMR Advance Techniques. Vascular Imaging. Class III
MR Advance Techniques Vascular Imaging Class III 1 Vascular Imaging There are several methods that can be used to evaluate the cardiovascular systems with the use of MRI. MRI will aloud to evaluate morphology
More informationVolume visualization. Volume visualization. Volume visualization methods. Sources of volume visualization. Sources of volume visualization
Volume visualization Volume visualization Volumes are special cases of scalar data: regular 3D grids of scalars, typically interpreted as density values. Each data value is assumed to describe a cubic
More informationJune 05, 2018, Version 3.0.6
June 05, 2018, Version 3.0.6 VolViCon is an advanced application for reconstruction of computed tomography (CT), magnetic resonance (MR), ultrasound, and x-rays images. It gives features for exporting
More informationRT_Image v0.2β User s Guide
RT_Image v0.2β User s Guide RT_Image is a three-dimensional image display and analysis suite developed in IDL (ITT, Boulder, CO). It offers a range of flexible tools for the visualization and quantitation
More informationCertificate in Clinician Performed Ultrasound (CCPU)
Certificate in Clinician Performed Ultrasound (CCPU) Syllabus Physics Tutorial Physics Tutorial Purpose: Training: Assessments: This unit is designed to cover the theoretical and practical curriculum for
More informationAssessing Accuracy Factors in Deformable 2D/3D Medical Image Registration Using a Statistical Pelvis Model
Assessing Accuracy Factors in Deformable 2D/3D Medical Image Registration Using a Statistical Pelvis Model Jianhua Yao National Institute of Health Bethesda, MD USA jyao@cc.nih.gov Russell Taylor The Johns
More informationRespiratory Motion Compensation for C-arm CT Liver Imaging
Respiratory Motion Compensation for C-arm CT Liver Imaging Aline Sindel 1, Marco Bögel 1,2, Andreas Maier 1,2, Rebecca Fahrig 3, Joachim Hornegger 1,2, Arnd Dörfler 4 1 Pattern Recognition Lab, FAU Erlangen-Nürnberg
More informationTechnical Publications
GE Medical Systems Technical Publications Direction 2188003-100 Revision 0 Tissue Volume Analysis DICOM for DICOM V3.0 Copyright 1997 By General Electric Co. Do not duplicate REVISION HISTORY REV DATE
More informationAbbie M. Diak, PhD Loyola University Medical Center Dept. of Radiation Oncology
Abbie M. Diak, PhD Loyola University Medical Center Dept. of Radiation Oncology Outline High Spectral and Spatial Resolution MR Imaging (HiSS) What it is How to do it Ways to use it HiSS for Radiation
More informationMEDICAL IMAGING 2nd Part Computed Tomography
MEDICAL IMAGING 2nd Part Computed Tomography Introduction 2 In the last 30 years X-ray Computed Tomography development produced a great change in the role of diagnostic imaging in medicine. In convetional
More informationMindray. Hand-carried Diagnostic Ultrasound System. Expanding the Envelope of Performance and Flexibility
M7 Mindray M7 Hand-carried Diagnostic Ultrasound System Expanding the Envelope of Performance and Flexibility M7 Diagnostic Ultrasound System Equipped for Quality Radiology Cardiology Outpatient Emergency
More informationQIBA PET Amyloid BC March 11, Agenda
QIBA PET Amyloid BC March 11, 2016 - Agenda 1. QIBA Round 6 Funding a. Deadlines b. What projects can be funded, what cannot c. Discussion of projects Mechanical phantom and DRO Paul & John? Any Profile
More informationRetrospective Spiral Respiratory Correlated Imaging with Varian RPM
Retrospective Spiral Respiratory Correlated Imaging with Varian RPM This is a Quick Step Guide for Retrospective Spiral Respiratory Correlated Imaging (4D CT) using the Varian RPM device v1.7 with the
More informationNon-Destructive Failure Analysis and Measurement for Molded Devices and Complex Assemblies with X-ray CT and 3D Image Processing Techniques
SINCE2013 Singapore International NDT Conference & Exhibition 2013, 19-20 July 2013 Non-Destructive Failure Analysis and Measurement for Molded Devices and Complex Assemblies with X-ray CT and 3D Image
More informationLimited view X-ray CT for dimensional analysis
Limited view X-ray CT for dimensional analysis G. A. JONES ( GLENN.JONES@IMPERIAL.AC.UK ) P. HUTHWAITE ( P.HUTHWAITE@IMPERIAL.AC.UK ) NON-DESTRUCTIVE EVALUATION GROUP 1 Outline of talk Industrial X-ray
More informationn o r d i c B r a i n E x Tutorial DTI Module
m a k i n g f u n c t i o n a l M R I e a s y n o r d i c B r a i n E x Tutorial DTI Module Please note that this tutorial is for the latest released nordicbrainex. If you are using an older version please
More informationDICOM Overview: Stability and Evolution
THE DICOM 2013 INTERNATIONAL CONFERENCE & SEMINAR March 14-16 Bangalore, India Kevin O Donnell DICOM Overview: Stability and Evolution Toshiba Medical Research Institute - USA, Inc. Sr. R&D Manager, Pacifica,
More information