DICOM Conformance Statement for GALILEI. Software Version V6.0
|
|
- Nathan Mosley
- 6 years ago
- Views:
Transcription
1 DICOM Conformance Statement for GALILEI Software Version V6.0 Version 1.0, December 6 th, 2011
2 Contents Revision History... 2 Purpose... 2 References... 2 Terms and Definitions... 2 Abbreviations... 3 Implementation Model... 5 WORKLIST SCU... 5 STORAGE SCU... 5 Sequencing of real-world activities...6 AE Specifications... 6 WORKLIST SCU... 6 Association Policies... 6 SOP Classes... 7 Presentation Context... 7 Worklist Information Model... 7 Storage SCU... 8 Association Policies... 8 SOP Classes... 8 Presentation Context... 9 Media Storage... 9 Support of extended character sets... 9 Security... 9 Annex Encapsulated PDF IOD Secondary Capture Image IOD Modules Patient Module General Study Module General Series Module General Equipment Module SC Equipment Module Encapsulated Document Series Module Encapsulated Document Module General Image Module General Pixel Module Ziemer Ophthalmic Systems AG DICOM Conformance Statement page 1 of 14
3 Revision History Version Date of Issue Author Description 1.0 December 06 th 2011 Daniel Keller Initial Release Purpose This document is the DICOM Conformance Statement for the GALILEI G2 device. It describes compliance with the DICOM Version 3.0 standard including DICOM Service Classes, Information Objects and Communication Protocols. This document has been written in accordance with part PS 3.2 of the DICOM Version 3.0 standard. Familiarity with the DICOM standard is assumed. This Conformance Statement is intended for use by system integrators who wish to connect DICOM equipment with the GALILEI G2 device. This document specifies conformance with the DICOM standard, including limitations and restrictions on conformance. Careful review and comparison of this Conformance Statement with the Conformance Statements of other equipment must be done to determine whether integration will achieve a desired result. This document is essential to integrating DICOM-compliant applications and equipment, but does not guarantee system functionality by itself. References [DICOM] NEMA Standards Publication PS , Digital Imaging and Communications in Medicine (DICOM), 2009, available at Terms and Definitions Informal definitions are provided for the following terms used in this Conformance Statement. The DICOM Standard [DICOM] is the authoritative source for formal definitions of these terms. Abstract Syntax: the information agreed to be exchanged between applications, generally equivalent to a Service/Object Pair (SOP) Class. Example: Ultrasound Image Storage SOP Class, where Ultrasound Image refers to the Object and Storage to the Service. Application Entity (AE): an end point of a DICOM information exchange. Application Entity Title: identifier of an Application Entity. Application Context: the specification of the type of communication used in between two Application Entities. Association: a network communication channel set up in between two Application Entities. Attribute: a unit of information in an object definition which is referred to by a tag. Information Object Definition (IOD): the specified set of Attributes that comprise a type of data object; does not represent a specific instance of the data object, but rather a class of similar data objects that have the same properties. The Attributes may be specified as Mandatory (Type 1), Required but possibly unknown (Type 2), or Optional (Type 3), and there may be conditions associated with the use of an Attribute (Types 1C and 2C) Ziemer Ophthalmic Systems AG DICOM Conformance Statement page 2 of 14
4 Media Application Profile: the specification of DICOM information objects and encoding exchanged on removable media. Module: a set of Attributes within an Information Object Definition that are logically related to each other. Negotiation: first phase of Association establishment that allows Application Entities to agree on the types of data to be exchanged and how that data will be encoded. Presentation Context: the set of DICOM network services used over an Association, as negotiated between Application Entities; includes Abstract Syntaxes and Transfer Syntaxes. Protocol Data Unit (PDU): a packet (piece) of a DICOM message sent across the network. Devices must specify the maximum size packet they can receive for DICOM messages. Service Class Provider (SCP): role of an Application Entity that provides a DICOM network service; typically, a server that performs operations requested by another Application Entity (Service Class User). Service Class User (SCU): role of an Application Entity that uses a DICOM network service. Service/Object Pair (SOP) Class: the specification of the network or media transfer (service) applied on a particular information object definition (IOD). Example: Ultrasound Image Storage where Ultrasound Image refers to the IOD and Storage refers to the service. Service/Object Pair (SOP) Instance: a specific instance of a Service/Object Pair Class. Example a concrete Ultrasound image sample supposed to be stored. Tag: a numeric identifier for a data element, consisting of a group and element part. If the group part is odd, the tag refers to a private (manufacturer-specific) data element. Transfer Syntax: the encoding used for exchange of DICOM information objects and messages. Unique Identifier (UID): a globally unique dotted decimal string that identifies a specific object or a class of objects; an ISO-8824 Object Identifier Value Representation (VR): the data type of DICOM data element, such as text, an integer, a person s name, or a code. DICOM information objects can be transmitted with either explicit identification of the type of each data element (Explicit VR), or without explicit identification (Implicit VR); with Implicit VR, the receiving application must use a DICOM data dictionary to look up the format of each data element. Abbreviations The following abbreviations are used in this document. ACSE Association Control Service Element AE Application Entity CD Compact Disc CD-R Compact Disc Recordable CT Computer Tomography DICOM Digital Imaging and Communications in Medicine DIMSE DICOM Message Service Element EPDF Encapsulated PDF ID Identification / Identifier 2010 Ziemer Ophthalmic Systems AG DICOM Conformance Statement page 3 of 14
5 IOD Information Object Definition IPv4 Internet Protocol version 4 IPv6 Internet Protocol version 6 ISO International Standards Organization JPEG Joint Photographic Experts Group MR Magnetic Resonance MWL Modality Worklist Management PDF Portable Document Format PDU Protocol Data Unit SC Secondary Capture SCP Service Class Provider SCU Service Class User SOP Service Object Pair TCP/IP Transmission Control Protocol / Internet Protocol UID Unique Identifier VM Value Multiplicity VR Value Representation 2010 Ziemer Ophthalmic Systems AG DICOM Conformance Statement page 4 of 14
6 Implementation Model DICOM Standard Interface GALILEI sends queries and shows results WORKLIST-SCU Application Entity Remote AE Receives queries, sends matches GALILEI creates and sends new examinations STORAGE-SCU Application Entity Remote AE Receives instances WORKLIST SCU WORKLIST-SCU is activated when the user pushes the DICOM button within the data management panel. In this case, a pre-defined query is sent to a remote AE and the resulting matches are shown in the list. STORAGE SCU STORAGE-SCU is activated when the user pushes the DICOM button top right. In this case, a new instance of the Encapsulated PDF Storage SOP Class or Secondary Capture Image Storage SOP Class is created and sent to a remote AE Ziemer Ophthalmic Systems AG DICOM Conformance Statement page 5 of 14
7 Sequencing of real-world activities MWL / Storage SCU MWL SCP Storage SCP Query MWL Receive MWL Select MWL Item Acquire Data Correlate Data / MWL Item Store Data Note that no Storage Commitment Request is sent by the Storage SCU. AE Specifications WORKLIST SCU Association Policies Application Context Name Max PDU Length Bytes Implementation UID Implementation Version dcm4che Ziemer Ophthalmic Systems AG DICOM Conformance Statement page 6 of 14
8 SOP Classes SOP Class Name SOP Class UID Modality Worklist Information Model FIND Presentation Context Abstract Syntax Transfer Syntax Name UID Name UID Modality Worklist Information - Find Explicit VR Little Endian Implicit VR Little Endian Extension Negotiation Not supported Not supported Worklist Information Model Attribute Tag Types of Matching Accession Number (0008,0050) Universal Matching Referring Physician s Name (0008,0090) Universal Matching Patient s Name (0010,0010) Universal Matching Patient ID (0010,0020) Universal Matching Patient s Birth Date (0010,0030) Universal Matching Patient s Sex (0010,0040) Universal Matching Patient s Weight (0010,1030) Universal Matching Medical Alerts (0010,2000) Universal Matching Allergies (0010,2110) Universal Matching Pregnancy Status (0010,21C0) Universal Matching Study Instance UID (0020,000D) Universal Matching Requesting Physician (0032,1032) Universal Matching Requesting Service (0032,1033) Universal Matching Requested Procedure Description (0032,1060) Universal Matching Requested Procedure Code Sequence (0032,1064) Universal Matching Admission ID (0038,0010) Universal Matching Special Needs (0038,0050) Universal Matching Current Patient Location (0038,0300) Universal Matching Patient State (0038,0500) Universal Matching Scheduled Procedure Step Sequence (0040,0100) Universal Matching 2010 Ziemer Ophthalmic Systems AG DICOM Conformance Statement page 7 of 14
9 >Modality (0008,0060) Single Value Matching >Requested Contrast Agent (0032,1070) Universal Matching >Scheduled Station AE Title (0040,0001) Single Value Matching >Scheduled Procedure Step Start Date (0040,0002) Single Value Matching >Scheduled Procedure Step Start Time (0040,0003) Universal Matching >Scheduled Performing Physician s Name (0040,0006) Universal Matching >Scheduled Procedure Step Description (0040,0007) Universal Matching >Scheduled Procedure Step ID (0040,0009) Universal Matching >Scheduled Station Name (0040,0010) Universal Matching >Scheduled Procedure Step Location (0040,0011) Universal Matching >Pre-Medication (0040,0012) Universal Matching >Comments On The Scheduled Procedure Step (0040,0400) Universal Matching Requested Procedure ID (0040,1001) Universal Matching Requested Procedure Priority (0040,1003) Universal Matching Patient Transport Arrangements (0040,1004) Universal Matching Placer Order Number (0040,2016) Universal Matching Filler Order Number (0040,2017) Universal Matching Confidentiality Constraint on Patient Data (0040,3001) Universal Matching Modality, Scheduled Station AE Title and Scheduled Procedure Step Start Date are used as configurable filter criteria conjunction. Any permutations are used. Storage SCU Association Policies Application Context Name Max PDU Length Bytes Implementation UID Implementation Version dcm4che-2.0 SOP Classes SOP Class Name SOP Class UID Encapsulated PDF Storage Secondary Image Capture Storage Ziemer Ophthalmic Systems AG DICOM Conformance Statement page 8 of 14
10 Presentation Context Abstract Syntax Transfer Syntax Name UID Name UID Secondary Image Capture Storage Encapsulated PDF Storage JPEG Baseline Implicit VR Little Endian Explicit VR Little Endian Implicit VR Little Endian Extension Negotiation Not supported Not supported Not supported Not supported GALILEI does not support any media services. Media Storage Support of extended character sets GALILEI supports only the ISO_IR 100 character set. GALILEI does not support any security profiles. Security 2010 Ziemer Ophthalmic Systems AG DICOM Conformance Statement page 9 of 14
11 Annex Encapsulated PDF IOD GALILEI creates Encapsulated PDF IOD objects containing context dependent reports. The following table describes the modules. IE Module Usage Patient Study Series Equipment Encapsulated Document Patient Clinical Trial Subject General Study Patient Study Clinical Trial Study Encapsulated Document Series Clinical Trial Series General Equipment SC Equipment Encapsulated Document SOP Common Secondary Capture Image IOD GALILEI creates also Secondary Capture Image IOD objects containing context dependent reports. The following table describes the modules. IE Module Usage Patient Study Series Equipment Image Patient Clinical Trial Subject General Study Patient Study Clinical Trial Study General Series Clinical Trial Series General Equipment SC Equipment General Image Image Pixel Device 2010 Ziemer Ophthalmic Systems AG DICOM Conformance Statement page 10 of 14
12 Specimen SC Image Overlay Plane Modality LUT VOI LUT SOP Common Modules Patient Module Patient s Name (0010,0010) PN from worklist Always Patient s ID (0010,0020) LO from worklist potentially empty Patient s Birth Date (0010,0030) DA from worklist Always Patient s Sex (0010,0040) CS from worklist potentially empty General Study Module Study Date (0008,0020) DA from worklist always Study Time (0008,0030) TM from worklist always Accession Number (0008,0050) SH from worklist potentially empty Referring Physician s Name (0008,0090) PN from worklist potentially empty Study Description (0008,1030) LO from worklist potentially empty Study Instance UID (0020, 000D) UI from worklist or generated by the system always Study ID (0020, 0010) SH Generated by the system always General Series Module Series Date (0008,0021) DA Date the series started Always Series Time (0008,0031) TM Time the series started Always Modality (0008,0060) CS OT Always Series Instance UID (0020,000E) UI Generated automatically Always Series Number (0020,0011) IS Incremental number Always Laterality (0020,0060) CS L or R Always Performed Procedure Step Start Date (0040,0244) DA Date of examination Always Performed Procedure Step Start Time (0040,0245) TM Time of examination Always Performed Procedure Step ID (0040,0253) SH = (0040,0009)attribute in worklist potentially empty Comments on the Performed Procedure Step (0040,0280) ST Entered by the user potentially empty 2010 Ziemer Ophthalmic Systems AG DICOM Conformance Statement page 11 of 14
13 General Equipment Module Attribute name Tag VR Value Presence Manufacturer (0008,0070) LO "Ziemer Ophthalmic Systems AG" Always Institution Name (0008,0080) LO From the configuration file potentially empty Institution Address (0008,0081) ST From the configuration file potentially empty Station Name (0008,1010) SH From the configuration file potentially empty Institutional Department Name (0008,1040) LO From the configuration file potentially empty Manufacturer's Model Name (0008,1090) LO "Galilei G2 Always Software Versions (0018,1020) LO "6" Always SC Equipment Module Modality (0008,0060) CS "OT" Always Conversion Type (0008,0064) CS "SYN" Always Secondary Capture Device Manufacturer (0018,1016) LO Ziemer Ophthalmic Systems AG" Always Secondary Capture Device Manufacturer's Model Name (0018,1018) LO GALILEI G2 Always SOP Common Module Specific Character Set (0008,0005) CS ISO_IR 100 Always Instance Creation Date (0008,0012) DA Current date Always Instance Creation Time (0008,0013) TM Current time Always SOP Class UID (0008,0016) UI epdf/sc storage uid Always SOP Instance UID (0008,0018) UI Generated automatically Always Encapsulated Document Series Module Modality (0008,0060) CS OT Always Series Instance UID (0020,00E) UI Generated automatically Always Series Number (0020,0011) IS Incremental number Always Performed Procedure Step Start Date (0040,0244) DA Date of examination Always Performed Procedure Step Start Time (0040,0245) TM Time of examination Always Performed Procedure Step ID (0040,0253) SH equals to (0040,0009) attribute in worklist potentially empty Comments on the Performed Procedure Step (0040,0280) ST Examination Notes potentially empty 2010 Ziemer Ophthalmic Systems AG DICOM Conformance Statement page 12 of 14
14 Encapsulated Document Module Instance Number (0020,0013) CS Sequential number increased for each instance within a series Always Content Date (0008,0023) DA Dateof examination Always Content Time (0008,0033) TM Time of examination Always Burned In Annotation (0028,0301) CS YES Always MIME Type of Encapsulated (0042,0012) LO application/pdf Document Always Encapsulated Document (0042,0011) OB Raw Data Always General Image Module Instance Number (0020,0013) CS Incremental number Always Content Date (0008,0023) DA Dateof examination Always Content Time (0008,0033) TM Time of examination Always General Pixel Module Samples Per Pixel (0028,0002) US 3 Always Photometric Interpretation (0028,0004) CS RGB Always Planar Configuration (0028,0006) US 0 Always Rows (0028,0010) US height of the image Always Columns(0028,0011) (0028,0011) US width of the image Always Bits Allocated (0028,0100) US 8 Always Bits Stored (0028,0101) US 8 Always High Bit (0028,0102) US 7 Always Pixel Representation (0028,0103) US 0 Always Pixel Data (7FE0,0010) OB content of the image Always 2010 Ziemer Ophthalmic Systems AG DICOM Conformance Statement page 13 of 14
DICOM CONFORMANCE STATEMENT for Keratograph ( )
DICOM CONFORMANCE STATEMENT for Keratograph 2.3.14 (2013-03-01) CONFORMANCE STATEMENT OVERVIEW The OCULUS Keratograph is used to measure corneal topography and is designed for use for the purpose of fitting
More informationUscan. DICOM Conformance Statement
DICOM Conformance Statement - Uscan Uscan DICOM Conformance Statement Software Version: 4.1.1 Date: 3 August 2018 Signostics, Inc., a subsidiary of EchoNous, Inc. 8310 154th Ave NE, Suite 200 Redmond,
More informationDICOM Conformance Statement. report 42. Version 3.2. Reporting Application for Cardiovascular MR and CT
DICOM Conformance Statement report 42 Version 3.2 Reporting Application for Cardiovascular MR and CT 2016-11-18 CIRCLE Cardiovascular Imaging Inc Panarctic Plaza Suite 250, 815 8 th Avenue SW Calgary,
More informationDICOM Conformance Statement for IMAGEnet 5
DICOM Conformance Statement for IMAGEnet 5 Ver.1.0 2013/6/3 TOPCON Corporation ALL RIGHTS RESERVED Conformance Statement for IMAGEnet 5 1 Contents 1. Foreword... 4 1.1. References... 4 1.2. Abbreviations...
More informationTechnical Publications
Technical Publications Direction DOC1135035 Revision 1 Venue 40 Version 3.xx GE Healthcare Copyright 2012 by General Electric Co. Do not duplicate THIS PAGE LEFT INTENTIONALLY BLANK CONFORMANCE STATEMENT
More informationSonoWin Picture Archiving System
Page 1 of 13 SonoWin Picture Archiving System DICOM SSCU Module Version 4.1 DICOM Conformance Statement Page 2 of 13 1 DOCUMENT HISTORY...4 2 INTRODUCTION...4 2.1 SOURCES OF INFORMATION...4 2.2 ACRONYMS
More informationDICOM Conformance Statement
DICOM Conformance Statement TOPCON Corporation TOPCON SPECULAR MICROSCOPE SP-1P Version 1.10 Document Version: 1 Date: 2014-02-17 1 CONFORMANCE STATEMENT OVERVIEW This document declares conformance to
More informationDICOM Conformance Statement
BK Ultrasound DICOM Conformance Statement For bkhub (Software Version 3.0.0 and higher) Ultrasonix Medical Corporation 130 4311 Viking Way Richmond, BC V6V 2K9 Canada www.bkultrasound.com support@bkultrasound.com
More informationDICOM Conformance Statement
DICOM Conformance Statement Application Annex: HeartNavigator R2.0.5 Koninklijke Philips N.V. 2015 All rights are reserved. Document Number: ICAP-PF.0015391 Issued by: Philips Medical Systems Nederland
More informationMediaWorkStation. MWS DICOM Push Interface. DICOM Conformance Statement. Version 2.0. English
MediaWorkStation MWS DICOM Push Interface Version 2.0 DICOM Conformance Statement English 1-2014 Abbreviations AE DICOM IE IOD MPPS MWL MWS PACS PDU SOP SCP SCU Application Entity Digital Imaging and Communication
More informationDICOM Conformance Statement
Visante AC-OCT Version 3.0 Carl Zeiss Meditec, Inc. 5160 Hacienda Drive Dublin, CA 94568 USA www.meditec.zeiss.com P/N: 2660021134750 Rev: C 9/03/2009 Page 1 of 22 1 Conformance Statement Overview This
More informationDICOM Conformance Statement August 23, 2010 Version 1.0 ImageWorks Internal document number:
DICOM Conformance Statement August 23, 2010 Version 1.0 ImageWorks Internal document number: 0000062023 ImageWorks 250 Clearbrook Road, Suite 240 Elmsford, NY 10523 (914) 592-6100 1 Revision History Version
More informationDICOM Conformance Statement
DICOM Conformance Statement ECLOS Tokyo, Japan (SN-C357E) Copyright Hitachi Medical Corporation. 2007, 2008. All rights reserved. History Revision Description Date Rev. 1.0 Initial. 2007/02/01 Rev 2.0
More informationDICOM Conformance Statement
DICOM Conformance Statement SCENARIA Tokyo, Japan E1E-HC0002-01 Hitachi, Ltd. 2016. All rights reserved. History Revision Description Date Rev. 1.0 Initial. 2016/04/01 ii E1E-HC0002 Contents History...
More informationTechnical Publications
Technical Publications Direction DOC0913087 Revision 1.0 VOLUSON Voluson S6/S8 11.x.x Copyright 2011 by General Electric Co. Do not duplicate GE Medical Systems THIS PAGE LEFT INTENTIONALLY BLANK REVISION
More informationWhole Body X-ray CT System Supria. DICOM Conformance Statement
Whole Body X-ray CT System Supria DICOM Conformance Statement Tokyo, Japan (SN-C633E) Copyright Hitachi Medical Corporation. 2013, 2014. All rights reserved. History Revision Description Date Rev. 1.0
More informationSCORE 3D Workstation DICOM CONFORMANCE STATEMENT
Document No.: S517-E105 Revision No.: A DIGITAL ANGIOGRAPHY SYSTEM DAR-9500f SCORE 3D Workstation DICOM CONFORMANCE STATEMENT Revision History Rev. Date Content of Change First 2013.09 Newly issued. A
More informationKodak Point of Care CR systems. DICOM Conformance Statement
Kodak Point of Care CR systems DICOM Conformance Statement Kodak QC Software Version 2.1.x Aug 21, 2005 Document #AT001008-00 Revision 1.0 Table of Contents REVISION HISTORY 4 ACRONYMS, ABBREVIATIONS AND
More informationDICOM. Conformance Statement For VINNO Medical Ultrasound System Revision 2.0. Copyright 2012 by VINNO Technology (Suzhou) Co., Ltd.
DICOM Conformance Statement For VINNO Medical Ultrasound System Revision 2.0 Copyright 2012 by VINNO Technology (Suzhou) Co., Ltd. 1 / 37 Revision History Document version Date Author Description 1.0 2014-07-10
More informationDICOM Conformance Statement
DICOM Conformance Statement Application Annex: Cath Analysis Package (CAAS2000) on Xcelera R3.2L1 SP2 Koninklijke Philips Electronics N.V. 2011 All rights are reserved. Document Number: PIIOffc.0000075
More informationnstream Version 3.1 DICOM Conformance Statement
Image Stream Medical nstream Version 3.1 DICOM Conformance Statement Revision History: Revision Date Author Notes A 03/02/2006 TMT/EP Initial Control A 03/05/2006 TMT Minor cosmetic changes A 03/07/2006
More informationVersion 7 DICOM Conformance Statement. Document Version 3.02, June 2009
Version 7 DICOM Conformance Statement Document Version 3.02, June 2009 1 Conformance Statement Overview The application described in this Conformance Statement VEPRO EMR Manager PACS is a collection of
More informationefx Software DICONDE Conformance Statement
efx Software DICONDE Conformance Statement Version 1.2 9/29/2015 North Star Imaging, Inc. 1 DICOM conformance statement overview The North Star Imaging s efx Software is an imaging viewing software with
More informationPrintlink III-ID/IV. Revision History. Date Version Description 20/08/2004 Ver First edition
Revision History Date Version Description 20/08/2004 Ver. 1.00 First edition NOTE: Descriptions in this document are subject to change without prior notice. Printlink III-ID/IV DICOM 3.0 Conformance Statement
More informationNewVision Fundus Medical Imaging Suite
NewVision Fundus Medical Imaging Suite NewVision Fundus DICOM v.3.2 BTT Bilgi Teknoloji Tasarim Ltd. Document version: 2.0 10 November 2011 DICOM Conformance Statement 1. Overview This document describes
More informationKARL STORZ OR1 FUSION V1.3.1 DICOM Conformance Statement
KARL STORZ OR1 FUSION V1.3.1 DICOM Conformance Statement PRODUCT INFO OR1 OR1 87 1.2 02/2018/PI-E 1/21 1 Table of Content 1 Abbreviations...3 1.1 Definitions...3 1.2 References...3 2 CONFORMANCE STATEMENT
More informationDICOM CONFORMANCE STATEMENT FOR DIAGNOSTIC ULTRASOUND SYSTEM MODEL SSA-640A V5.0
DICOM CONFORMANCE STATEMENT FOR DIAGNOSTIC ULTRASOUND SYSTEM TM MODEL SSA-640A V5.0 TOSHIBA MEDICAL SYSTEMS CORPORATION 2015 ALL RIGHTS RESERVED Trademarks Viamo is a trademark of Toshiba Medical Systems
More informationREGIUS CONSOLE CS-2. Revision History. Date Version Description 02/08/2004 Ver This Conformance Statement applies to DICOM3.0 (2000 version).
Revision History Date Version Description 02/08/2004 Ver.1.00 This Conformance Statement applies to DICOM3.0 (2000 version). REGIUS CONSOLE CS-2 DICOM 3.0 Conformance Statement Ver.1.00 02/08/2004 1 Contents
More informationTechnical Publication. DICOM Conformance Statement. iplan 3.0. Document Revision 1. November 17, Copyright BrainLAB AG
Technical Publication DICOM Conformance Statement Document Revision 1 November 17, 2009 2009 Copyright BrainLAB AG 1 Conformance Statement Overview This is a conformance statement for the BrainLAB software
More informationX-Porte DICOM Conformance Statement
21919 30th Dr. SE, Bothell, WA 98021-3904 USA Telephone 1.425.951.1200 Facsimile 1.425.951.1201 www.sonosite.com Document Number: Revision: Title: D10711 D X-Porte DICOM Conformance Statement CHANGE HISTORY:
More informationDICOM Conformance Statement. Forum
Document Number: CG-LEH-MS-065 Revision: 2.0 Date: 2009-07-23 Author: Tobias Kurzke DICOM Conformance Statement Forum Version 2.0 Carl Zeiss Surgical GmbH Carl-Zeiss-Str. 22 73447 Oberkochen Germany www.meditec.zeiss.com
More informationWhole Body X-ray CT System Supria. DICOM Conformance Statement
Whole Body X-ray CT System Supria DICOM Conformance Statement Tokyo, Japan E1E-HC0001-02 Hitachi, Ltd. 2016. All rights reserved. ii E1E-HC0001 History Revision Description Date Rev. 1.0 Initial. 2016/4/1
More informationTechnical Publications
Technical Publications 1694829 Revision 3 OEC Elite MiniView Software Release Workstation 1.x Copyright 2015 by General Electric Co. g Do not duplicate GE Healthcare REVISION HISTORY REV DATE REASON FOR
More informationTopcon Medical Systems
Topcon Medical Systems EZ Lite 2 Version 1.2 DICOM Conformance Statement November 1, 2013 Rev 1.1 Topcon Medical Systems, Inc. 111 Bauer Drive, Oakland, NJ 07436, USA Phone: (201) 599-5100 Fax: (201) 599-5250
More informationDICOM Conformance Statement
DICOM Conformance Statement Application Annex: AneurysmFlow R1.1 On Interventional Workspot R1.5 Koninklijke Philips N.V. 2018 All rights are reserved. Issued by: Philips Medical Systems Nederland BV,
More informationRetinal imaging control software NM. DICOM Conformance Statement
Retinal imaging control software NM DICOM Conformance Statement To Customers 1. Canon reserves the right to change the specifications of the product without prior notice. Microsoft, Windows, Windows XP
More informationKARL STORZ AIDA V1.3.1 DICOM Conformance Statement PRODUCT INFO OR1 OR /2017/PI-E 1/32
KARL STORZ AIDA V1.3.1 DICOM Conformance Statement PRODUCT INFO OR1 OR1 92 2.0 02/2017/PI-E 1/32 Change History Version Date Changes Reason Editor BB-02 07.02.2017 Whole document (table numbering, spelling)
More informationDICOM Conformance Statement FORUM
Document Number: CG-LEH-MS-203 Revision: 1.0 Date: 2010-04-21 DICOM Conformance Statement FORUM Version 2.5 Carl Zeiss Surgical GmbH Carl-Zeiss-Str. 22 73447 Oberkochen Germany www.meditec.zeiss.com Document:
More informationAVIA (Dx MM) DICOM 3.0 Conformance Statement
AVIA (Dx MM) DICOM 3.0 Conformance Statement AVIA (Dx MM) is a product of Medasys Digital Systems. Table of Contents 1INTRODUCTION... 4 1.1SCOPE AND AUDIENCE... 4 1.2REFERENCES... 4 1.3ACRONYMS AND ABBREVIATIONS...
More informationDICOM Conformance Statement June 24, 2011 Version 0.4 ImageWorks Internal document number:
DICOM Conformance Statement June 24, 2011 Version 0.4 ImageWorks Internal document number: 0000062015 ImageWorks 250 Clearbrook Road, Suite 240 Elmsford, NY 10523 (914) 592-6100 www.imageworkscorporation.com
More informationMediaWorkStation. DICOM Worklist Interface. DICOM Conformance Statement. Version 1.1. English
MediaWorkStation DICOM Worklist Interface Version 1.1 English Edition 1-2016 Abbreviations AE DICOM IOD IE MPPS MPEG-2 MWL MWS PACS PDU SOP SCP SCU UID VL VR Related Documents Application Entity Digital
More informationDICOM Conformance Statement
Date: 2011-09-14 DICOM Conformance Statement HFA II i series Instrument Version 5.1 Carl Zeiss Meditec, Inc. 5160 Hacienda Drive Dublin, CA 94568 USA www.meditec.zeiss.com Document: DICOM_Conformance_Statement_HFA2i_5.1.doc
More informationDICOM CONFORMANCE STATEMENT
g GE Medical Systems Technical Publications Direction 5146235-100 Revision 3 Reporting Tool DICOM Copyright 2005-2006 by General Electric Co. Do not duplicate THIS PAGE LEFT INTENTIONALLY BLANK i REVISION
More informationDx Server for Windows NT DICOM 3.0 Conformance Statement
Dx Server for Windows NT DICOM 3.0 Conformance Statement NAME FONCTION VISA AUTHOR Alain Battistini Senior Engineer CONFORM TO ORIGINAL REVIEW Jean-François Hoh Senior Engineer CONFORM TO ORIGINAL APPROVAL
More informationArtwork consists of twenty three (23) 8½ x 11 inch pages.
Artwork consists of twenty three (23) 8½ x 11 inch pages. REV AUTHORED BY DATE P KUPOVICH 9/17/04 REV DRAFTED BY DATE G CORRIDORI 9/17/04 PROPRIETARY: This document contains proprietary data of Hologic,
More informationDx Server for Windows NT DICOM 3.0 Conformance Statement
Dx Server for Windows NT DICOM 3.0 Conformance Statement NAME FONCTION VISA AUTHOR Alain Battistini Senior Engineer CONFORM TO ORIGINAL REVIEW Jean-François Hoh Senior Engineer CONFORM TO ORIGINAL APPROVAL
More informationFusionXD 2.1 DICOM Conformance Statement
FusionXD 2.1 DICOM Conformance Statement Contents 1 Introduction... 3 1.1 References... 3 1.2 Integration and Features... 3 1.3 Definitions, Acronyms and Abbreviations... 3 2 Services... 4 3 Networking...
More informationDICOM CONFORMANCE STATEMENT FOR VANTAGE-GALAN TM VERSION V5.0
DICOM CONFORMANCE STATEMENT FOR VANTAGE-GALAN TM VERSION V5.0 CANON MEDICAL SYSTEMS CORPORATION 2018 ALL RIGHTS RESERVED Trademarks VANTAGE-GALAN is trademark of Canon Medical Systems Corporation. This
More informationArtwork consists of sixty-five (65) 8 ½ inch x 11 inch pages.
Artwork consists of sixty-five (65) 8 ½ inch x 11 inch pages. REV AUTHORED BY DATE P.KUPOVICH 2/14/08 REV DRAFTED BY DATE G CORRIDORI 2/27/08 PROPRIETARY: This document contains proprietary data of Hologic,
More informationDICOM Conformance Statement
eradlink Inc. LaserPro 16 Digitizing Scanner DICOM Conformance Statement Version 1.0 March 16, 2002 eradlink Inc. 22750 Hawthorne Blvd. Torrance, California 90505-3364 310-373-5673 (phn) 313-373-9763 (fax)
More informationTechnical Publications
g GE Heathcare Technical Publications Direction DOC0660253 Revision 11 NM General Purpose 600 Series * * Refer to Section 1 for a list of products in NM General Purpose 600 Series family to which this
More informationDICOM Conformance Statement
Group of Companies ifa systems AG ifa united i-tech, Inc. Augustinusstr. 11b 1850 SE 17 th Street Suite C Suite 107 50226 Frechen Fort Lauderdale, FL 33316 Germany USA Phone: +49 2234 93367-0 Phone: +1
More informationFusionXD 2.0 DICOM Conformance Statement
FusionXD 2.0 DICOM Conformance Statement 1 Introduction 1.1 Revision History See the Revision History in the beginning of this document 1.2 References Reference REF1 Document Digital Imaging and Communications
More informationDICOM Conformance Statement FORUM
DICOM Conformance Statement FORUM Version 2.6 Carl Zeiss Meditec AG Goeschwitzerstraße 51-52 07745 Jena Germany www.meditec.zeiss.com Document: CG-LEH-MS-254-DICOM Conformance Statement 2.6.doc Page 1
More informationDICOM Conformance Statement
For SonixTouch Q+, SonixMDP/SP/OP Q+ and SonixOne Diagnostic Ultrasound Systems (and Systems with Software Version 6.1.0 and Newer) Analogic Corporation 8 Centennial Drive Peabody, MA 01960 USA bkultrasound.com
More informationGE Healthcare. Technical Publications. ConnectR Plus Version 5.0 DICOM CONFORMANCE STATEMENT. GE Healthcare IT. Direction DOC Revision 0.
GE Healthcare Technical Publications Direction DOC0509300 Revision 0.1 ConnectR Plus Version 5.0 GE Healthcare IT Copyright 2008. General Electric Company 1 Revision History Revision # Author Description
More informationSonovision DICOM Conformance Statement
Sonovision DICOM Conformance Statement Document Version: 1.0 Product Name: Sonovision Release: 2.0 Manufacturer: Peridot Technologies Date: February 15, 2011 Document Used By: Sales & Marketing, Customer
More informationDICOM V3.0 Conformance Statement. SenoIris 1SP2
DICOM V3.0 Conformance Statement SenoIris 1SP2 Image Diagnost International Reproduction of this document without prior written approval is prohibited. Image Diagnost International reserves the right to
More informationDICOM Conformance Statement
Document Number: 67923 Revision: F Date: 2010-03-01 Author: Paolo Pochendorfer DICOM Conformance Statement Cirrus HD-OCT 4000 Instrument and Review Software Version 5.0 Carl Zeiss Meditec, Inc. 5160 Hacienda
More informationTechnical Publication. DICOM Conformance Statement. BrainSUITE NET 1.5. Document Revision 1. March 5, Copyright BrainLAB AG
Technical Publication DICOM Conformance Statement Document Revision 1 March 5, 2009 2009 Copyright BrainLAB AG 1 Conformance Statement Overview This is a conformance statement for the BrainLAB software
More informationDICOM Conformance Statement, Biim Ultrasound App Version 1
Biim Ultrasound, AS Title: Document: DICOM Conformance Statement, Biim Ultrasound App Version 1 D00085 Rev B DICOM Conformance Statement, Biim Ultrasound App Version 1 Page 1 of 10 Table of Contents 1
More informationTechnical Publications
g GE Heathcare Technical Publications Direction DOC0374470 Revision 3 Discovery NM530c Copyright 2016 by General Electric Co. Do not duplicate g GE Heathcare LIST OF REVISIONS REV DATE DESCRIPTION PAGES
More informationAG Mednet Agent DICOM Conformance Statement Version 1.3
AG Mednet Agent DICOM Conformance Statement Version 1.3 AG Mednet, Inc. Page 2 CONTENTS 1 INTRODUCTION...5 1.1 REVISION HISTORY...5 1.2 AUDIENCE...5 1.3 REMARKS...5 2 NETWORKING...7 2.1 IMPLEMENTATION
More informationHologic Physician s Viewer 5.0 DICOM Conformance Statement
Hologic Physician s Viewer 5.0 DICOM Conformance Statement MAN-00239 REV 001 Page 1 of 18 1 INTRODUCTION... 4 1.1 Purpose of the Document...4 1.2 References...4 1.3 Definitions...4 2 IMPLEMENTATION MODEL...
More informationC-DAC s Medical Informatics Software Development Kit (SDK) for DICOM PS Conformance Statement
C-DAC s Medical Informatics Software Development Kit (SDK) for DICOM PS 3.0-2015 Conformance Statement Company Name: Centre of Development for Advanced Computing Product Name: C-DAC s Medical Informatics
More informationParascript AccuDetect CAD Software System
Parascript AccuDetect CAD Software System Computer Aided Detection for Digital Mammography DICOM CONFORMANCE STATEMENT US Software Version: 6.1 Parascript, LLC 6273 Monarch Park Place Longmont, CO 80503
More informationDICOM Conformance Statement
Date: 2017 10 02 DICOM Conformance Statement VideoStation Version 3.50 Softneta K. Barsausko str. 59 LT-51423 Kaunas Lithuania Page 1 of 38 1 Conformance Statement Overview VideoStation is an image acquisition
More informationTechnical Publications
Technical Publications Direction DOC1094319 Revision 2 Vivid S5 version 12 Copyright 2012 by General Electric Co. Do not duplicate THIS PAGE LEFT INTENTIONALLY BLANK CONFORMANCE STATEMENT OVERVIEW Page
More informationDICOM CONFORMANCE STATEMENT
Ultrasonix Medical Corporation DICOM CONFORMANCE STATEMENT For SonixTablet, SonixTouch, 2010 SonixMDP/SP/OP and Legacy SonixMDP Diagnostic Ultrasound Systems (Software Version 6.0.3 and above) Ultrasonix
More informationDICOM Conformance Statement
Revision: 1.0 Date: 2015-05-28 DICOM Conformance Statement FORUM Cataract Workplace Version 1.0 Carl Zeiss Meditec AG Goeschwitzer Strasse 51-52 07745 Jena Germany www.zeiss.com/med Document: DICOM_Conformance_Statement_FORUM_Cataract_Workplace_V1.0.Docx
More informationJiveX Enterprise PACS Solutions. JiveX DICOM Worklist Broker Conformance Statement - DICOM. Version: As of
JiveX Enterprise PACS Solutions JiveX DICOM Worklist Broker Conformance Statement - DICOM Version: 4.7.2 As of 2015-08-03 VISUS Technology Transfer GmbH Universitätsstr. 136 D-44799 Bochum Germany Phone:
More informationDICOM 3.0 Conformance Statement for PlatinumOne Systems
DICOM 3.0 Conformance Statement for PlatinumOne Systems 0.0 Revision History: Revision ECN Date Description A 3032 09/12/2002 New Release 1.0 Purpose: Define the DICOM Conformance statement associated
More informationCopyright FUJIFILM Corporation, Japan. August, th Edition 897N100760F
DICOM Conformance Statement ***** FDR-1000AWS CR-IR363AWS for DICOM Storage DICOM Storage Commitment DICOM MWM DICOM MPPS DICOM Print DICOM Query / Retrieve DICOM Media Storage (Standard) August, 2010
More informationTechnical Publications
g GE Heathcare Technical Publications Direction DOC0660253 Revision 5 NM General Purpose 600 Series * * Refer to Section 1 for a list of products in NM General Purpose 600 Series family to which this Conformance
More informationDICOM Conformance Statement AIDA HD Connect
DICOM Conformance Statement AIDA HD Connect PRODUCT INFO OR1 KARL STORZ GmbH & Co. KG Mittelstraße 8 78532 Tuttlingen/Germany Postfach 230 78503 Tuttlingen/Germany Phone: +49 (0)7461 708-0 Fax: +49 (0)7461
More informationQPC XSCAN32 DICOM 3.0 Conformance Statement Document Version October 2004
QPC XSCAN32 DICOM 3.0 Conformance Statement Document Version 1.3.0 28 October 2004 QPC XSCAN32 DICOM 3.0 CONFORMANCE STATEMENT Revision 1.3.0 2 8 October 2004 Page 1 of 22 Table of Contents 0 INTRODUCTION...
More informationDICOM Conformance Statement. DSI Release 4.4. Document Number June Copyright Philips Medical Systems Nederland B.V.
Philips Medical Systems DICOM Conformance Statement DSI Release 4.4 Document Number 4522 220 84061 6 June 1997 Copyright Philips Medical Systems Nederland B.V. 1997 Philips Medical Systems apple PHILIPS
More informationVersion 9 DICOM Conformance Statement. Version 3.05, September 2015
Version 9 DICOM Conformance Statement Version 3.05, September 2015 1 Conformance Statement Overview The application described in this conformance statement, VEPRO EMR Manager PACS, is a collection of processes
More informationTechnical Publications
Technical Publications Direction LU42818 Revision 1 4.0 Express Insight Copyright 2006 By General Electric Co. Do not duplicate g GE Medical Systems REVISION HISTORY REV DATE REASON FOR CHANGE 1 June 30,
More informationDICOM Conformance Statement
Date: 2013-12-10 DICOM Conformance Statement CIRRUS TM HD-OCT 5000 and 500 Instrument CIRRUS TM HD-OCT 4000 and 400 Instrument Version 7.0 Carl Zeiss Meditec, Inc. 5160 Hacienda Drive Dublin, CA 94568
More informationAloka ProSound DICOM
11/18/09 Page 1 of 17 Aloka ProSound DICOM Aloka ProSound C3 and C3cv Ultrasound Imaging System ProSound Versions 1.0 and 1.1 DICOM 11/18/09 Page 2 of 17 Table of Contents 1 Introduction...4 1.1 Scope...4
More informationTITAN DICOM Conformance Statement
TITAN DICOM Conformance Statement This document contains confidential information that is proprietary to SonoSite. Neither the document nor the information contained therein should be disclosed or reproduced
More informationDx Server for Windows NT DICOM 3.0 Conformance Statement
Dx Server for Windows NT DICOM 3.0 Conformance Statement NAME FONCTION VISA AUTHOR Alain Battistini Senior Engineer CONFORM TO ORIGINAL REVIEW Jean-François Hoh Senior Engineer CONFORM TO ORIGINAL APPROVAL
More informationDICOM Conformance Statement. CT AV Series Product Line. Document Number February 1997
Philips Medical Systems DICOM Conformance Statement CT AV Series Product Line Document Number 4522 983 65911 28 February 1997 Copyright Philips Medical Systems Nederland B.V. 1997 Philips Medical Systems
More information1 Introduction Scope and audience References Acronyms and abbreviations 3. 2 Implementation model... 4
NAME FONCTION VISA AUTHOR Alain Battistini Senior Engineer CONFORM TO ORIGINAL REVIEW Jean-François Hoh Senior Engineer CONFORM TO ORIGINAL APPROVAL Pascal Gilbert-Jeantet CONFORM TO ORIGINAL Revision
More informationDICOM Conformance Statement
Revision: B Date: 2015-05-18 DICOM Conformance Statement CIRRUS TM HD-OCT 400/4000 and 500/5000 Instrument and Review Software Version 7.6.x/8.1.x Carl Zeiss Meditec, Inc. 5160 Hacienda Drive Dublin, CA
More informationTechnical Publications
g GE Healthcare Technical Publications Direction DOC1629000 Revision 2 LOGIQ P9/P7 R2.x Copyright 2016 by General Electric Co. g GE Healthcare Do not duplicate THIS PAGE LEFT INTENTIONALLY BLANK CONFORMANCE
More informationDICOM Conformance Statement. for ES9410 DICOM
DICOM Conformance Statement. for ES9410 DICOM (DICOM Embedded Printer) 1 DICOM 3.0 Conformance Statement Summary: This document is the DICOM Conformance Statement of the Print Service Class Provider (SCP)
More informationMirada XD DICOM Conformance Statement
Mirada XD DICOM Conformance Statement mm1050-4 1 Conformance Statement Overview Mirada XD implements the necessary DICOM services to read DICOM images and other objects from the file system and save secondary
More informationDICOM 3.0 Conformance Statement DXIMAGE RIS
DICOM 3.0 Conformance Statement DXIMAGE RIS Document Reference (Référence du document) 08/Feb20/ABA/RIS/570E Table of Contents (Table des Matières) 1 Introduction 5 1.1 Scope and Audience 5 1.2 References
More informationOASIS V4.0 DICOM Conformance Statement Rev. 3
0BMR Imaging System OASIS V4.0 DICOM Conformance Statement Rev. 3 Tokyo, Japan E1E-BM7403-3 Copyright Hitachi Medical Corporation. 2011. All rights reserved. Revision History Revision Date Change Description
More informationTechnical Publications
g GE Healthcare Technical Publications Direction 2391078-5-8EN Revision 1 Seno Advantage 2.0 WorkStation do not duplicate Copyright 2011 By General Electric Co. THIS PAGE LEFT INTENTIONALLY BLANK Page
More informationTechnical Publications
DIRECTION DOC0821438REV 1 VIVID S5 11 Technical Publications Direction DOC0821438 Revision 1 Vivid S5 version 11 for DICOM Copyright 2009 By General Electric Co. Do not duplicate GE Healthcare DIRECTION
More informationDICOM. Conformance Statement. Panorama Release 6. Panorama 0.6T Panorama 0.23T Panorama 0.23T I/T Panorama 0.23T R/T
DICOM Conformance Statement Panorama Release 6 Panorama 0.6T Panorama 0.23T Panorama 0.23T I/T Panorama 0.23T R/T Koninklijke Philips Electronics N.V. 2005 All rights are reserved. This DICOM Conformance
More informationDE32-DCM DentalEye 3.2. DICOM conformance statement
DentalEye 3.2 Table of contents 1. INTRODUCTION... 4 1.1. DentalEye Enterprise Application... 4 1.2. About this Document... 4 1.3. Integration and Validation... 4 1.4. Future Evolution... 5 1.5. Sources
More informationPunctual Dicom Workstation
DICOM Conformance Statement Punctual Dicom Workstation Company Name Product Name Product Version 2.0 Document number 2008-1001 Date June 1, 2009 Punctual Software Inc. Punctual Dicom Workstation TABLE
More informationDICOM Conformance Statement. cvi 42. Version 5.6. Workstation for Cardiovascular MR and CT
DICOM Conformance Statement cvi 42 Version 5.6 Workstation for Cardiovascular MR and CT 2017-02-24 CIRCLE Cardiovascular Imaging Inc Panarctic Plaza Suite 250, 815 8 th Avenue SW Calgary, Alberta, Canada
More informationDICOM Conformance Statement. for C911 DICOM PRINTER SERIES : C911/C931 DICOM ES9411/ES9431 DICOM Pro9431 DICOM
DICOM Conformance Statement for C911 DICOM PRINTER SERIES : C911/C931 DICOM ES9411/ES9431 DICOM Pro9431 DICOM (DICOM Embedded Printer) 1 DICOM 3.0 Conformance Statement Summary: This document is the DICOM
More informationdysect DICOM Conformance Statement dysect DICOM Conformance Statement
dysect DICOM Conformance Statement 1 dysect DICOM Conformance Statement (041-00-0007 H) dysect Conformance Statement.doc DeJarnette Research Systems, Inc. 401 Washington Avenue, Suite 1010 Towson, Maryland
More informationCoActiv, LLC CoActiv Medical Business Solutions EXAM-PACS Conformance Statement
CoActiv EXAM-PACS DICOM Conformance Statement Page 1 of 40 0. COVER PAGE CoActiv, LLC CoActiv Medical Business Solutions EXAM-PACS Conformance Statement The information contained in this document is subject
More information