HP Eight-Port SAS/SATA RAID Host Bus Adapter

Size: px
Start display at page:

Download "HP Eight-Port SAS/SATA RAID Host Bus Adapter"

Transcription

1 HP Eight-Port SAS/SATA RAID Host Bus Adapter Installation Guide June 2006 (Second edition) Part Number

2 Legal notices Copyright 2005, 2006 Hewlett-packard Development Company, L.P. The information contained herein is subject to change without notice. The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. HP shall not be liable for technical or editorial errors or omissions contained herein. Microsoft and Windows are U.S. registered trademarks of Microsoft Corporation. June 2006 (Second edition) Part Number Audience assumptions This document is for the person who installs, administers, and troubleshoots servers and storage systems. HP assumes you are qualified in the servicing of computer equipment and trained in recognizing hazards in products with hazardous energy levels. 2

3 Contents 1 Adapter features Connectors on the adapter board... 4 Summary of specifications Installation procedure Preparing the server... 5 Installing the adapter hardware... 5 Connecting the adapter to other devices... 6 Completing the adapter installation procedure SAS BIOS configuration utility SAS BIOS features... 7 Boot initialization with the BBS... 7 Starting the SAS BIOS configuration utility... 7 Configuration utility screens... 8 Adapter List screen... 8 Global Properties screen... 9 Adapter Properties screen RAID Properties screens SAS Topology screen Device Properties screen Exit screen Performing configuration tasks Creating a RAID 0 array Creating a RAID 1 array Viewing RAID array properties Managing an array Locating a disk drive Selecting a boot disk Moving arrays Electrostatic discharge Preventing electrostatic discharge Grounding methods to prevent electrostatic discharge Regulatory compliance notices European Union regulatory notice BSMI notice Korean notice Contents 3

4 1 Adapter features Connectors on the adapter board 1 Health LED (blinks green during normal operation, glows amber if HBA has failed) 2 Port activity LED (blinks green during data transfer) 3 Internal 4x SAS connector, port 1I 4 Internal 4x SAS connector, port 2I Summary of specifications The HP Eight-Port SAS/SATA RAID Host Bus Adapter is a low-profile, 64-bit, 133-MHz PCI-X host bus adapter. It supports SAS data transfer rates of up to 3 Gb/s, and SATA data transfer rates of up to 1.5 Gb/s. For more information about the features and specifications of the adapter, and for information about compatibility, see the QuickSpecs on the product-specific page of the HP website, Adapter features 4

5 2 Installation procedure WARNING! To reduce the risk of personal injury or damage to the equipment, consult the safety information and user documentation provided with the server before attempting the installation. Many servers are capable of producing energy levels that are considered hazardous and are intended to be serviced only by qualified personnel who have been trained to deal with these hazards. Do not remove enclosures or attempt to bypass any interlocks that may be provided for the purpose of removing these hazardous conditions. WARNING! When working with equipment installed in a rack, be sure that the equipment and rack are stable before beginning the installation procedure. The installation procedure involves the following steps: Preparing the server Installing the adapter hardware Connecting the adapter to other devices Completing the adapter installation procedure, including updating the firmware and installing drivers These steps are described in more detail in the following sections. Preparing the server 1. Perform a normal system shutdown. 2. Power down the server. 3. Power down all peripheral devices attached to the server. 4. Unplug the AC power cord from the outlet, and then unplug it from the server. 5. Disconnect all peripheral devices attached to the server. Installing the adapter hardware CAUTION: Electrostatic discharge (ESD) can damage electronic components. Be sure that you are properly grounded before beginning this procedure. For more information, see the Electrostatic Discharge section of this guide. 1. Remove or open the server access panel and locate the PCI/PCI-X bus expansion slots. (For detailed instructions, see the documentation that was provided with the server.) WARNING! To reduce the risk of personal injury from hot surfaces, allow the internal system components to cool before touching them. 2. Remove or open the server access panel and locate the PCI/PCI-X bus expansion slots. (For detailed instructions, see the documentation that was provided with the server.) 3. Select the expansion slot that you want to use. 4. Depending on the server model, remove the retaining screw or open the expansion slot latch that secures the PCI/PCI-X slot. 5. Remove the slot cover. Save it to use for if you later decide to remove the adapter and leave the slot empty. 6. Insert the adapter into the slot, and press it firmly into place. The contacts on the adapter edge should be fully seated in the system board connector. 7. Depending on the server model, secure the adapter by replacing the retaining screw or by closing the slot latch. Installation procedure 5

6 Connecting the adapter to other devices The cables that are required to connect the adapter to other devices are provided with most HP server products that need them. Table 1 lists some cables that can be used with this adapter. All HP cables are keyed so that they cannot be installed incorrectly. Table 1 Cable kit part numbers Type of cable Description Part number Internal SAS/SATA Multi-lane A cable B21 Internal SAS/SATA Host fan cable B21 Internal SAS/SATA Target fan cable B21 Internal SAS/SATA Multi-lane B cable B21 Internal SAS/SATA Multi-lane 76-cm (30-in) cable B21 Internal SAS/SATA Multi-lane 48-cm (19-in) cable B21 You can order extra cables from an authorized HP reseller or authorized HP service provider. If the cable that you need is not listed here, or if you need additional ordering information, see Completing the adapter installation procedure 1. Verify that all cables are routed correctly and are not restricting or being pinched by other components. For the correct routing of the cables, see the server documentation. 2. Reconnect any peripheral devices to the server. 3. Plug the AC power cord into the server, and then into a grounded AC outlet. 4. Power on any peripheral devices attached to the server. 5. Power up the server. 6. If necessary, update the server ROM. The required firmware files are on either a CD in the adapter kit or the HP website, Instructions are provided with the files (in the case of the CD, in a booklet provided with the CD). 7. Install the adapter drivers. The drivers are also on either the CD in the adapter kit or the HP website, and instructions are again provided with the files. Installation procedure 6

7 3 SAS BIOS configuration utility SAS BIOS features The SAS BIOS is the bootable ROM code that manages SAS hardware resources. It is specific to a family of SAS controllers or processors. The SAS BIOS integrates with a standard system BIOS, extending the standard disk service routine provided through INT13h. During the boot time initialization, the SAS BIOS determines if the system BIOS has already installed other hard disks, such as an IDE drive. If the drives are already installed, the SAS BIOS maps any SAS or SATA drives it finds behind these drives. Otherwise, the SAS BIOS installs drives starting with the system boot drive. In this case, the system boots from a drive controlled by the SAS BIOS. Boot initialization with the BBS The SAS BIOS supports the BIOS boot specification (BBS), which enables you to choose which device to boot from by selecting the priority. If the system supports the BBS, use the system BIOS setup menu to select the boot order and drive order. In the system BIOS setup, the Boot Connection Devices menu lists the available boot options. Use that menu to select the device and rearrange the order. Exit to continue the boot process. Starting the SAS BIOS configuration utility If using SAS BIOS 6.xx and it includes the SAS BIOS configuration utility, you can change the default configuration of the SAS host adapters. The default values might change if there is a conflict between device settings or if the system performance needs optimizing. The version number of the SAS BIOS appears in a banner displayed on the computer monitor during bootup. If the configuration utility is available, the following message also appears during bootup: Press F8 to start LSI Logic Configuration Utility... NOTE: The exact key sequence might be different for different version numbers. This message remains on the screen for five seconds, giving you time to start the utility. If you press the F8 key, the message changes to: Please wait, invoking LSI Logic Configuration Utility... After a pause, the SAS BIOS configuration utility opens. The following messages might appear during the boot process: Adapter removed from boot order! This message appears when an adapter was removed from the system or was relocated behind a PCI bridge. Adapter configuration may have changed, reconfiguration is suggested! This message appears when the information in the non-volatile random access memory (NVRAM) is invalid. Updating Adapter List! This message appears when fewer than four adapters are in the boot order list and more adapters exist than are shown. NOTE: The SAS BIOS configuration utility can sometimes detect devices that the SAS BIOS cannot control (for example, tape drives and scanners require their own specific drivers). However, you can still use the configuration utility to modify some parameters for these devices. SAS BIOS configuration utility 7

8 Configuration utility screens All SAS BIOS configuration utility screens contain the following areas, starting at the top of the screen: Header area Identifies the utility and version number. Menu area Gives the title of the current screen. On screens other than the Adapter List screen, also identifies the adapter. Main area The main area for presenting data. This area has a cursor for item selection, and horizontal and vertical scroll bars if necessary. Footer area Provides general help information text. Adapter List screen The Adapter List screen is the first screen to appear when the SAS BIOS configuration utility opens. This screen provides information about each adapter installed in the system. If this host bus adapter is configured as the active boot controller in RBSU, you can change the adapter boot order sequence, add an adapter to the boot order, or remove an adapter from the boot order. To change the position of an adapter in the boot order sequence, move the cursor to the Boot Order field for that adapter and then press the - or + key. To add an adapter to the boot order list, move the cursor to the Boot Order field of the adapter and then press the Ins key. To remove an adapter from the boot order list, move the cursor to the Boot Order field of the adapter and then press the Del key. The configuration utility prompts you to save the changes before you exit the screen. The Adapter List screen is also the gateway to three other screens: The Global Properties screen, which enables you to change the way in which the BIOS displays information during the bootup procedure. To access this screen, press the Alt+N key combination. The Adapter Properties screen, which enables you to view adapter information and modify the boot support setting. This screen also provides access to most other screens in the utility, which you can use to perform RAID array configuration and management tasks, view device information, or format or verify devices. To access this screen, use the arrow keys to move the cursor to an adapter in the Adapter List field and then press the Enter key. The Exit Menu screen. To access this screen, press the Esc key. Each of these screens is described in more detail in the rest of this section. SAS BIOS configuration utility 8

9 Global Properties screen The Global Properties screen enables you to change the global scope settings. To access the Global Properties screen, press the Alt+N key combination while on the Adapter List screen. Table 2 Global properties field descriptions Field Pause when Boot Alert Displayed Boot information display mode Support interrupt Restore Defaults Description This option specifies whether the BIOS pauses for user acknowledgement after displaying an alert message during the boot process. To continue after displaying a message, select No. To wait for the user to press a key, select Yes. This option controls how much information the BIOS displays about adapters and devices during the boot process. Possible values are: Display adapters only Display adapters and all devices Display minimal information Display adapters and installed devices This option enables you to prevent a hook on INT40, if required. Possible values are: Hook interrupt (default) Bypass interrupt hook If you press the Enter key while this field is selected, the values in the other fields on this screen revert to their default settings. When you have finished on the Global Properties screen, you can: Return to the Adapter List screen by pressing the Alt+N key combination (this combination toggles between the Adapter List screen and the Global Properties screen). Access the Exit Menu screen by pressing the Esc key. SAS BIOS configuration utility 9

10 Adapter Properties screen The Adapter Properties screen lists information about the adapter. From this screen, you can access other screens in the utility that enable you to perform RAID array configuration and management tasks or view information about the SAS topology of the adapter. To perform RAID array configuration and management tasks, move the cursor to the RAID Properties field and then press the Enter key. The screen that is then displayed depends on whether the adapter has a RAID array configured. For more information, see RAID Properties screens on page 10. To view information about the devices connected to the adapter, move the cursor to the SAS Topology field and then press the Enter key. The SAS Topology screen also provides access to screens deeper in the hierarchy of the configuration utility that enable you to format or verify devices. RAID Properties screens The screen that is displayed when you select the RAID Properties link on the Adapter Properties screen depends on whether the adapter has a RAID array configured. If no RAID arrays are currently configured, the Select New Array Type screen is displayed. If at least one RAID array is currently configured, the View Array screen is displayed. SAS BIOS configuration utility 10

11 Select New Array Type screen This screen describes the types of RAID arrays that you can create, and enables you to select the type that you want to use. When you make your selection, the Create New Array screen opens. Create New Array screen The Create New Array screen enables you to select the disk drives for the new array. For a RAID 1 array, you are prompted to choose one of the following options when you add the first disk: Press the M key to keep the existing data and migrate to a RAID 1 array. Disk synchronization occurs. Press the D key to overwrite existing data and create a new RAID 1 array. No synchronization occurs. CAUTION: If you press the D key, the data on all disks in the array will be deleted. After you have configured the array, press the C key to create the array. You are prompted to save changes, which creates the array. When array creation is complete, the utility returns to the Adapter Properties screen. SAS BIOS configuration utility 11

12 View Array screen The View Array screen displays the current array configuration and provides access to the array management screen. To view the next array, press the Alt+N key combination. To perform management tasks on this array, move the cursor to the Manage Array field and press the Enter key. To create a new array, press the C key. Manage Array screen The Manage Array screen enables you to modify certain features of the currently selected array. If you select Manage Hot Spare, the utility displays a hot spare management screen that has the same layout as the Create New Array screen. If you select Synchronize Array, Activate Array, or Delete Array, an alert prompts you to press the Y key to confirm the selection or press the N key to reject the selection before beginning the process. SAS BIOS configuration utility 12

13 SAS Topology screen The SAS Topology screen provides basic information about each device that is connected to the adapter. (To view all the information listed for a device, scroll horizontally.) This screen also provides a means for you to identify the physical device in the system that corresponds to a device in the list. To view detailed information about a device, move the cursor to the appropriate Device Identifier field and then press the Alt+D keys. The Device Properties screen opens. To identify the physical device corresponding to a listed device, move the cursor to the appropriate Device Identifier field and then press the Enter key. The locator LED on the device glows. To clear Device Mappings for missing devices, press the C key at any time while on this screen. Device Properties screen The Device Properties screen displays information about a specific device. To access this screen, press the Alt+D key combination when the cursor is in the Device Identifier field of a device on the SAS Topology screen. To cycle to the next or previous device, press the Alt+N or Alt+P key combinations at any time while on this screen. This screen also provides access to the Format and Verify screens. To access either of these screens, move the cursor to the appropriate field and then press the Enter key. SAS BIOS configuration utility 13

14 Device Format screen This screen enables you to format a particular device. To access the Format screen, press the Enter key in the appropriate field on the Device Properties screen. To begin the format, press the F key. CAUTION: When you have started a format, you cannot pause or cancel it. NOTE: The formatting procedure sets the sector size to 512 bytes, even if the drive was previously formatted to another sector size. This is the only sector size that the SAS BIOS configuration utility supports on RAID arrays. Device Verify screen This screen enables you to verify a particular device. To access the Verify screen, press the Enter key in the appropriate field on the Device Properties screen. To begin the verify process, press the Enter key. You can cancel the verify process at any time by pressing the Esc key. If the logical block addresses (LBAs) can be reassigned or must be reassigned, the following prompt appears after you have pressed the Enter key: Reassign the block? (Yes, No, All, none, Cancel) SAS BIOS configuration utility 14

15 Exit screen The reassignment options are as follows: Yes Reassign only this block. If another block must be reassigned in the future, display the prompt again. No Do not reassign this block. If another block must be reassigned in the future, display the prompt again. All Reassign the current block, and automatically reassign other blocks that must be reassigned, without displaying the prompt again. none Do not reassign the current block, and do not automatically reassign any other blocks that must be reassigned. Do not display the prompt again. Cancel Do not reassign anything, and stop the Verify process. You must exit the SAS BIOS configuration utility properly because some changes take effect only during the exit process. To access the Exit screen, press the Esc key while in any screen in the utility. If an option is not relevant or unavailable, it is deactivated. Performing configuration tasks This section explains how to use the configuration utility to perform configuration tasks. Creating a RAID 0 array In a RAID 0 array, data is striped across multiple disk drives, combining the drives into one logical volume. This procedure maximizes storage capacity and performance. IMPORTANT: RAID 0 does not provide any data protection if a drive fails. To create a RAID 0 array: 1. Open the configuration utility. 2. On the Adapter List screen, select an adapter. 3. On the Adapter Properties screen, select RAID Properties. If the adapter already has a configured array, the View Array screen appears. Press the C key to create a new array, and then continue with the next step. If the adapter does not yet have a configured array, the Select New Array Type screen appears. Continue with the next step. 4. On the Select New Array Type screen, select Create RAID 0 Array. The Create New Array screen appears. This screen lists the drives that you can use to create the RAID 0 array. SAS BIOS configuration utility 15

16 When selecting drives for the RAID 0 array, remember the following limitations: Every drive in the array must be of the same type, either SATA (with extended command set support) or SAS (with SMART support). Each drive must have 512-byte blocks. Drives with removable media are not supported. The array must have at least two drives but no more than eight drives. RAID 0 arrays cannot have hot spare drives. 5. For each drive that you want in the array, move the cursor to the RAID Disk column for that drive and then press the + key, - key, or space bar. The No in that field changes to Yes, and the value in the Array Size field changes to reflect the new size of the array. 6. When you have finished configuring the array, press the C key and select Save changes. IMPORTANT: Be sure that the configuration is exactly as you want it. You cannot change the array after the number of drives in a RAID array is set. The configuration utility pauses while the array is created, and then returns to the Adapter Properties screen. 7. (Optional) To set this RAID 0 array as the boot volume, select the SAS Topology option on the Adapter Properties screen and then, on the screen that opens, set the boot volume. For more information, see Selecting a boot disk on page 18. Creating a RAID 1 array In a RAID 1 array, data is mirrored from one disk drive onto another one. This procedure increases reliability by providing protection against the failure of a single drive. For an even greater level of protection, you can configure a RAID 1 array with a hot spare. Then, if a drive fails, data that was on the failed drive is rebuilt to the hot spare from the mirrored drive. To create a RAID 1 array: 1. Open the configuration utility. 2. On the Adapter List screen, select an adapter. 3. On the Adapter Properties screen, select RAID Properties. If the adapter already has a configured array, the View Array screen appears. Press the C key to create a new array, and then continue with the next step. If the adapter does not yet have a configured array, the Select New Array Type screen appears. Continue with the next step. 4. On the Select New Array Type screen, select Create RAID 1 Array. The Create New Array screen appears. This screen lists the drives that you can use to create the RAID 1 array. When selecting drives for the RAID 1 array, remember the following limitations: Every drive in the array must be of the same type, either SATA (with extended command set support) or SAS (with SMART support). Each drive must have 512-byte blocks. Drives with removable media are not supported. A RAID 1 array must have two drives (three if you use a hot spare). 5. For each drive that you want in the array, move the cursor to the RAID Disk column for that drive and then press the + key, - key, or space bar. The No in that field changes to Yes, and the value in the Array Size field changes to reflect the new size of the array. When you add the first drive, the utility prompts you to keep existing data or overwrite existing data. To keep any existing data on the first drive, press the M key. To overwrite any data on the first drive, press the D key. SAS BIOS configuration utility 16

17 6. (Optional) To add a hot spare to the array, move the cursor to the Hot Spr column and press the + key, - key, or space bar. The drive that you select as the hot spare conforms to the same limitations as other drives in the array. IMPORTANT: Although you can create two arrays per adapter, you can have only one hot spare per adapter. This hot spare acts a global hot spare for both arrays. However, if you configure one SAS RAID 1 array and one SATA RAID 1 array and then add a SAS hot spare, the hot spare will work only for the SAS array. 7. When you have finished configuring the array, press the C key and select Save changes. The configuration utility pauses while the array is created, and then returns to the Adapter Properties screen. 8. (Optional) To set this RAID 1 array as the boot volume, select the SAS Topology option on the Adapter Properties screen and then, on the screen that opens, set the boot volume. For more information, see Selecting a boot disk on page 18. Viewing RAID array properties 1. Open the configuration utility. 2. On the Adapter List screen, select an adapter. 3. On the Adapter Properties screen, select the RAID Properties option. The View Array screen opens, displaying the properties of the first array on the adapter. 4. If the adapter has more than one array configured, view the properties of the next array by pressing the Alt+N key combination. Managing an array 1. Open the configuration utility. 2. On the Adapter List screen, select an adapter. 3. On the Adapter Properties screen, select RAID Properties. 4. On the View Array screen, select Manage Array. From this screen, you can: Manage hot spares Synchronize an array Activate an array Delete an array Managing hot spares 1. On the Manage Array screen, select Manage Hot Spare, and then perform one of the following actions: To remove an existing hot spare, move the cursor to the hot spare and then press the + key, - key, or space bar. To add a hot spare, move the cursor to a disk in the list and then press the + key, - key, or space bar. IMPORTANT: For a drive to be suitable as a hot spare, it must be valid RAID drive. For more information about the limitations, see the Creating a RAID 1 array section. IMPORTANT: Although you can create two arrays per adapter, you can have only one hot spare per adapter. This hot spare acts a global hot spare for both arrays. However, if you configure one SAS RAID 1 array and one SATA RAID 1 array and then add a SAS hot spare, the hot spare will work only for the SAS array. 2. Press the C key. 3. Select Save changes. 4. Exit this menu to enable the changes. The configuration utility pauses while the hot spare configuration is changed. Synchronizing an array When a RAID 1 array is synchronized, the data on the secondary drive of the mirror is updated by copying changed data from the primary drive. SAS BIOS configuration utility 17

18 To start a synchronization, select Synchronize Array on the Manage Array screen and then press the Y key. (To cancel a synchronization, press the N key.) Activating an array An array becomes inactive if, for example, it is removed from one controller or computer and moved to another one. The Activate Array option enables you to reactivate an inactive array that has been added to a system. This option is only available when the selected array is currently inactive. To activate an array, select Activate Array on the Manage Array screen and then press the Y key. (To cancel the activation, press the N key.) After a pause, the array becomes active. Deleting an array CAUTION: If the array contains any data that you want to keep, back up the data before deleting the array. To delete an array, select Delete Array on the manage Array screen, and then press the Y key. (To cancel the deletion, press the N key.) After a pause, the firmware deletes the array. NOTE: When an array has been deleted, you cannot recover it. When a RAID 1 array is deleted, the data is preserved on the primary disk. The master boot records of other disks in the array are deleted. For other RAID types, the master boot records of all disks are deleted. Locating a disk drive There are two ways to physically locate a disk drive: On the Create New Array screen, the locator LED on the drive glows when you select a drive to be part of a RAID array. When the RAID array is created, or if you deselect the drive from the array, the locator LED is extinguished. On the SAS Topology screen, move the cursor to the drive and press the Enter key. The locator LED on the drive remains lit until you press another key. Selecting a boot disk 1. Open the configuration utility. 2. On the Adapter List screen, select an adapter. 3. On the Adapter Properties screen, select SAS Topology. The SAS Topology screen opens. If selection of a boot device is supported, the Alt+B option is listed at the bottom of the screen. If a device is currently configured as the boot device, the Device Info column displays the word Boot. To remove the boot disk designator, move the cursor to the current boot disk and press the Alt+B key combination. The adapter no longer has a designated boot device. To select a boot disk, move the cursor to the disk and press the Alt+B key combination. The selected disk moves to scan ID 0 on the next boot and remains at this position. There can be only one boot disk. Moving arrays When you remove an array and install it into another system (or reinstall it into the same system), the array is initially inactive and must be reactivated. To reactivate an array, follow the procedure described in Activating an array on page 18. If the moved or reinstalled volume is the boot volume, you will see a non-system disk message and the system will not boot. To enable the system to boot, restart the system and then press the F8 key when prompted during system initialization. When the BIOS configuration utility opens, activate the array as described previously and then restart the system. You can have only one hot spare per adapter. If you install a RAID 1 array with a hot spare into an adapter that already has an active RAID 1 array and a hot spare, the SAS Topology screen of the BIOS configuration utility reports the hot spare in the added array as Not Responding. In this case, after you have activated the added RAID 1 array, restart the system and then open the BIOS configuration utility and delete the second hot spare. The SAS Topology screen then reports the drive as Responding. SAS BIOS configuration utility 18

19 4 Electrostatic discharge Preventing electrostatic discharge To prevent damaging the system, be aware of the precautions you must follow when setting up the system or handling parts. A discharge of static electricity from a finger or other conductor can damage system boards or other static-sensitive devices. This type of damage can reduce the life expectancy of the device. To prevent electrostatic damage: Avoid hand contact by transporting and storing products in static-safe containers. Keep electrostatic-sensitive parts in their containers until they arrive at static-free workstations. Place parts on a grounded surface before removing them from their containers. Avoid touching pins, leads, or circuitry. Be sure you are properly grounded when touching a static-sensitive component or assembly. Grounding methods to prevent electrostatic discharge Several methods are used for grounding. Use one or more of the following methods when handling or installing electrostatic-sensitive parts: Use a wrist strap connected by a ground cord to a grounded workstation or computer chassis. Wrist straps are flexible straps with a minimum of 1 megohm ± 10 percent resistance in the ground cords. To provide proper ground, wear the strap snug against the skin. Use heel straps, toe straps, or boot straps at standing workstations. Wear the straps on both feet when standing on conductive floors or dissipating floor mats. Use conductive field service tools. Use a portable field service kit with a folding static-dissipating work mat. If you do not have any of the suggested equipment for proper grounding, have an authorized HP reseller install the part. For more information on static electricity or assistance with product installation, contact an authorized reseller. Electrostatic discharge 19

20 5 Regulatory compliance notices European Union regulatory notice This product complies with the following EU Directives: Low Voltage Directive 73/23/EEC EMC Directive 89/336/EEC Compliance with these directives implies conformity to applicable harmonized European standards (European Norms) which are listed on the EU Declaration of Conformity issued by Hewlett-Packard for this product or product family. This compliance is indicated by the following conformity marking placed on the product: This marking is valid for non-telecom products and EU harmonized Telecom products (e.g., Bluetooth). BSMI notice This marking is valid for EU non-harmonized Telecom products. *Notified body number (used only if applicable refer to the product label). Korean notice Regulatory compliance notices 20

HP BladeSystem c-class Enclosure Troubleshooting Guide

HP BladeSystem c-class Enclosure Troubleshooting Guide HP BladeSystem c-class Enclosure Troubleshooting Guide Part Number 460224-002 July 2009 (Second Edition) Copyright 2007, 2009 Hewlett-Packard Development Company, L.P. The information contained herein

More information

Sun StorageTek. 1U Rackmount Media Tray Reference Guide. Sun Doc Part Number: Second edition: December 2007

Sun StorageTek. 1U Rackmount Media Tray Reference Guide. Sun Doc Part Number: Second edition: December 2007 Sun StorageTek nl 1U Rackmount Media Tray Reference Guide Sun Doc Part Number: 875 4297 10 Second edition: December 2007 Legal and notice information Copyright 2007 Hewlett Packard Development Company,

More information

Nvidia Quadro FX 5600 graphics card and auxiliary power adapter cable installation

Nvidia Quadro FX 5600 graphics card and auxiliary power adapter cable installation Nvidia Quadro FX 5600 graphics card and auxiliary power adapter cable installation HP xw8600 and xw9400 Workstations This document describes how to install an Nvidia Quadro FX 5600 graphics card and an

More information

HP Ethernet 1Gb 2-port 332T Adapter User Guide

HP Ethernet 1Gb 2-port 332T Adapter User Guide HP Ethernet 1Gb 2-port 332T Adapter User Guide Abstract This document is for the person who installs, administers, and troubleshoots servers and storage systems. HP assumes you are qualified in the servicing

More information

SCSI Cable Installation Instructions

SCSI Cable Installation Instructions Identifying the SCSI Cable Parts SCSI Cable Installation Instructions for HP ProLiant DL100 Series Generation 2 Servers Item Description 1 Connector end 2 240 mm location 3 Terminator end Read instructions

More information

HP ProLiant NC1020 Cu Gigabit Server Adapter 32 PCI Single Port User Guide. June 2007 (Second Edition) Part Number B

HP ProLiant NC1020 Cu Gigabit Server Adapter 32 PCI Single Port User Guide. June 2007 (Second Edition) Part Number B HP ProLiant NC1020 Cu Gigabit Server Adapter 32 PCI Single Port User Guide June 2007 (Second Edition) Part Number 356292-00B 2004-2007 Hewlett-Packard Development Company, L.P. Broadcom is a registered

More information

Intel RAID Controller RS3DC040/ RS3DC080 Quick Installation User's Guide

Intel RAID Controller RS3DC040/ RS3DC080 Quick Installation User's Guide Intel RAID Controller RS3DC040/ RS3DC080 Quick Installation User's Guide Thank you for buying an Intel RAID Controller. Your Intel RAID Controller provides reliability, high performance, and fault-tolerant

More information

HP ProLiant DL580 Generation 2 and HP ProLiant ML570 Generation 2 Server Hot-Add Memory. July 2003 (Second Edition) Part Number

HP ProLiant DL580 Generation 2 and HP ProLiant ML570 Generation 2 Server Hot-Add Memory. July 2003 (Second Edition) Part Number HP ProLiant DL580 Generation 2 and HP ProLiant ML570 Generation 2 Server Hot-Add Memory July 2003 (Second Edition) Part Number 325398-002 2003 Hewlett-Packard Development Company, L.P. Microsoft and Windows

More information

Copyright 2017 HP Development Company, L.P.

Copyright 2017 HP Development Company, L.P. User Guide Copyright 2017 HP Development Company, L.P. Windows is either a registered trademark or trademark of Microsoft Corporation in the United States and/or other countries. Intel and Core are trademarks

More information

HP Smart Array P700m Controller for HP ProLiant Servers User Guide

HP Smart Array P700m Controller for HP ProLiant Servers User Guide HP Smart Array P700m Controller for HP ProLiant Servers User Guide Part Number 456549-001 October 2007 (First Edition) Copyright 2007 Hewlett-Packard Development Company, L.P. The information contained

More information

Replacing the Battery HP t5730 and t5735 Thin Clients

Replacing the Battery HP t5730 and t5735 Thin Clients Replacing the Battery HP t5730 and t5735 Thin Clients Copyright 2009 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Microsoft and Windows

More information

QuickSpecs. Models. Overview

QuickSpecs. Models. Overview Overview The HP Smart Array P800 is HP's first 16 port serial attached SCSI (SAS) RAID controller with PCI-Express (PCIe). It is the highest performing controller in the SAS portfolio and provides new

More information

HP ProLiant SL160z G6 Server

HP ProLiant SL160z G6 Server HP ProLiant SL160z G6 Server Installation Instructions Part Number 571291-004 Item Description 7 UID LED/SW 8 PCI Slot 9 Health LED 10 Power Button Rear Panel Components Figure 2 Rear panel components

More information

Upgrading and Servicing Guide

Upgrading and Servicing Guide Upgrading and Servicing Guide Copyright Information The only warranties for Hewlett-Packard products and services are set forth in the express statements accompanying such products and services. Nothing

More information

Hardware Reference Guide For Thin Clients

Hardware Reference Guide For Thin Clients b Hardware Reference Guide For Thin Clients Document Part Number: 254241-001 July 2002 This book provides basic hardware information for this series of Compaq Thin Clients. Å WARNING: Ä CAUTION: 2002 Compaq

More information

HP ProLiant DL380 Generation 3 Server Maintenance and Service Guide. May 2003 (Third Edition) Part Number

HP ProLiant DL380 Generation 3 Server Maintenance and Service Guide. May 2003 (Third Edition) Part Number HP ProLiant DL380 Generation 3 Server Maintenance and Service Guide May 2003 (Third Edition) Part Number 291916-003 2003 Hewlett-Packard Development Company, L.P. Microsoft, Windows, and Windows NT are

More information

Upgrading and Servicing Guide

Upgrading and Servicing Guide Upgrading and Servicing Guide Copyright Information The only warranties for Hewlett-Packard products and services are set forth in the express statements accompanying such products and services. Nothing

More information

Hardware Reference Guide HP Compaq t5000 Thin Client

Hardware Reference Guide HP Compaq t5000 Thin Client Hardware Reference Guide HP Compaq t5000 Thin Client Document Part Number: 334457-004 February 2005 This book provides basic hardware information for this series of thin clients. Å WARNING: Ä CAUTION:

More information

Intel NUC Kit NUC6CAYS User Guide

Intel NUC Kit NUC6CAYS User Guide Intel NUC Kit NUC6CAYS User Guide Regulatory Model NUC6CAY 1 Before You Begin CAUTIONS The steps in this guide assume you re familiar with computer terminology and with the safety practices and regulatory

More information

HP Proliant DL360 G6 Carrier-Grade Server Read Before Install

HP Proliant DL360 G6 Carrier-Grade Server Read Before Install HP Proliant DL360 G6 Carrier-Grade Server Read Before Install Carrier-Grade Instructions HP Part Number: COOPE-RRTF1 Published: September 2010 Edition: 1 Copyright 2010 Hewlett-Packard Development Company,

More information

Upgrading and Servicing Guide

Upgrading and Servicing Guide Upgrading and Servicing Guide The only warranties for Hewlett-Packard products and services are set forth in the express statements accompanying such products and services. Nothing herein should be construed

More information

HPE ProLiant MicroServer Gen10 Troubleshooting Guide

HPE ProLiant MicroServer Gen10 Troubleshooting Guide HPE ProLiant MicroServer Gen10 Troubleshooting Guide Abstract This document describes common procedures and solutions for troubleshooting the HPE ProLiant MicroServer Gen10. This document is intended for

More information

QuickSpecs. Models. HP Smart Array 642 Controller. Overview. Retired

QuickSpecs. Models. HP Smart Array 642 Controller. Overview. Retired Overview The Smart Array 642 Controller (SA-642) is a 64-bit, 133-MHz PCI-X, dual channel, SCSI array controller for entry-level hardwarebased fault tolerance. Utilizing both SCSI channels of the SA-642

More information

USER S GUIDE. Integrated RAID for SAS. April Version 1.1 DB

USER S GUIDE. Integrated RAID for SAS. April Version 1.1 DB USER S GUIDE Integrated RAID for SAS April 2007 DB15-000357-01 Proprietary Rights Notice This document contains proprietary information of LSI Logic Corporation. The information contained herein is not

More information

HP ProLiant DL165 G7 Server

HP ProLiant DL165 G7 Server HP ProLiant DL165 G7 Server Installation Instructions Part Number 601464-003 Identifying server components Front panel components Figure 1 Front Panel Components / 4 3.5 LFF HDD Item Description 1 Thumbscrews

More information

Dell SC5020 and SC5020F Storage System Owner s Manual

Dell SC5020 and SC5020F Storage System Owner s Manual Dell SC5020 and SC5020F Storage System Owner s Manual Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make better use of your product. CAUTION: A CAUTION indicates

More information

HP ProLiant DL385 Server Maintenance and Service Guide. January 2005 (First Edition) Part Number

HP ProLiant DL385 Server Maintenance and Service Guide. January 2005 (First Edition) Part Number HP ProLiant DL385 Server Maintenance and Service Guide January 2005 (First Edition) Part Number 376533-001 Copyright 2005 Hewlett-Packard Development Company, L.P. Microsoft, Windows, and Windows NT are

More information

Target Environments The Smart Array 6i Controller offers superior investment protection to the following environments: Non-RAID

Target Environments The Smart Array 6i Controller offers superior investment protection to the following environments: Non-RAID Overview The Smart Array 6i controller is an Ultra320 intelligent array controller for entry-level, hardware-based fault tolerance for protection of OS, applications, and logs. Most models have one internal-only

More information

QuickSpecs. Models. Overview

QuickSpecs. Models. Overview Overview The HP Smart Array P400 is HP's first PCI-Express (PCIe) serial attached SCSI (SAS) RAID controller and provides new levels of performance and reliability for HP servers, through its support of

More information

Troubleshooting Guide. HP t5325 Thin Clients

Troubleshooting Guide. HP t5325 Thin Clients Troubleshooting Guide HP t5325 Thin Clients Copyright 2009 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Microsoft and Windows are trademarks

More information

HP ProLiant MicroServer

HP ProLiant MicroServer HP ProLiant MicroServer Installation Sheet Part Number 615715-004 Panel door components Item Component 1 16 screws for HDD installation 2 4 screws for ODD installation 3 Screw driver Rear panel components

More information

HP NetServer E 800 Installation Guide

HP NetServer E 800 Installation Guide HP NetServer E 800 Installation Guide HP Part Number D9394-90000 Printed June 2000 Notice The information contained in this document is subject to change without notice. Hewlett-Packard makes no warranty

More information

Intel NUC Kit NUC7i7BNH, NUC7i5BNH & NUC7i3BNH User Guide. Intel NUC Kit NUC7i7BNH Intel NUC Kit NUC7i5BNH Intel NUC Kit NUC7i3BNH User Guide

Intel NUC Kit NUC7i7BNH, NUC7i5BNH & NUC7i3BNH User Guide. Intel NUC Kit NUC7i7BNH Intel NUC Kit NUC7i5BNH Intel NUC Kit NUC7i3BNH User Guide Intel NUC Kit NUC7i7BNH Intel NUC Kit NUC7i5BNH Intel NUC Kit NUC7i3BNH User Guide 1 Before You Begin CAUTIONS The procedures in this user guide assume familiarity with the general terminology associated

More information

Dell SCv300 and SCv320 Expansion Enclosure Owner's Manual

Dell SCv300 and SCv320 Expansion Enclosure Owner's Manual Dell SCv300 and SCv320 Expansion Enclosure Owner's Manual Regulatory Model: E03J, E04J Regulatory Type: E03J001, E04J001 Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that

More information

Internal Cabling Guide for the HP Smart Array 6400 Series Controller on an HP Integrity Server rx7620

Internal Cabling Guide for the HP Smart Array 6400 Series Controller on an HP Integrity Server rx7620 Internal Cabling Guide for the HP Smart Array 6400 Series Controller on an HP Integrity Server rx7620 May 2004 (Second Edition) Part Number 5990-8201 2004 Hewlett-Packard Development Company, L.P. Microsoft

More information

Intel NUC 7 Home, a Mini PC with Windows 10 NUC7i3BNHXF. Intel NUC 7 Home, a Mini PC with Windows 10 NUC7i5BNHXF

Intel NUC 7 Home, a Mini PC with Windows 10 NUC7i3BNHXF. Intel NUC 7 Home, a Mini PC with Windows 10 NUC7i5BNHXF Intel NUC 7 Home, a Mini PC with Windows 10 NUC7i3BNHXF Intel NUC 7 Home, a Mini PC with Windows 10 NUC7i5BNHXF Intel NUC 7 Enthusiast, a Mini PC with Windows 10 NUC7i7BNHXG User Guide 1 Before You Begin

More information

Intel NUC Kit NUC5i3MYHE & NUC5i5MYHE User Guide. Intel NUC Kit NUC5i3MYHE Intel NUC Kit NUC5i5MYHE User Guide

Intel NUC Kit NUC5i3MYHE & NUC5i5MYHE User Guide. Intel NUC Kit NUC5i3MYHE Intel NUC Kit NUC5i5MYHE User Guide Intel NUC Kit NUC5i3MYHE Intel NUC Kit NUC5i5MYHE User Guide 1 Before You Begin CAUTIONS The procedures in this user guide assume familiarity with the general terminology associated with personal computers

More information

QuickSpecs. Models SATA RAID Controller HP 6-Port SATA RAID Controller B21. HP 6-Port SATA RAID Controller. Overview.

QuickSpecs. Models SATA RAID Controller HP 6-Port SATA RAID Controller B21. HP 6-Port SATA RAID Controller. Overview. Overview HP 6 Port SATA RAID controller provides customers with new levels of fault tolerance for low cost storage solutions using SATA hard drive technologies. Models SATA RAID Controller 372953-B21 DA

More information

Intel NUC Kit NUC7i7BNH Intel NUC Kit NUC7i5BNH Intel NUC Kit NUC7i3BNH

Intel NUC Kit NUC7i7BNH Intel NUC Kit NUC7i5BNH Intel NUC Kit NUC7i3BNH Intel NUC Kit NUC7i7BNH Intel NUC Kit NUC7i5BNH Intel NUC Kit NUC7i3BNH User Guide 1 Before You Begin CAUTIONS The procedures in this user guide assume familiarity with the general terminology associated

More information

VP1-250X USER S MANUAL

VP1-250X USER S MANUAL VP1-250X Single-Slot 3U Open-VPX Rugged SATA/SAS Disk Module USER S MANUAL Copyright 2016 Phoenix International Systems, Inc. All Rights Reserved Table of Contents Introduction Features Part Number Key

More information

Tower to Rack and Rack to Tower System Conversion Guide

Tower to Rack and Rack to Tower System Conversion Guide Tower to Rack and Rack to Tower System Conversion Guide HP Workstation zx6000 HP Server rx2600 Manufacturing Part Number : A7857-90017 Edition E0802 Copyright 2002 Hewlett-Packard Company. Legal Notices

More information

Intel NUC Kit DN2820FYKH User Guide. Intel NUC Kit DN2820FYKH User Guide

Intel NUC Kit DN2820FYKH User Guide. Intel NUC Kit DN2820FYKH User Guide Intel NUC Kit DN2820FYKH User Guide 1 Before You Begin CAUTIONS The procedures in this user guide assume familiarity with the general terminology associated with personal computers and with the safety

More information

Wall-Mounting your HP TouchSmart. User Guide

Wall-Mounting your HP TouchSmart. User Guide Wall-Mounting your HP TouchSmart User Guide The only warranties for Hewlett-Packard products and services are set forth in the express statements accompanying such products and services. Nothing herein

More information

Intel NUC Kit D54250WYKH & D34010WYKH User Guide. Intel NUC Kit D54250WYKH Intel NUC Kit D34010WYKH User Guide

Intel NUC Kit D54250WYKH & D34010WYKH User Guide. Intel NUC Kit D54250WYKH Intel NUC Kit D34010WYKH User Guide Intel NUC Kit D54250WYKH Intel NUC Kit D34010WYKH User Guide 1 Before You Begin CAUTIONS The procedures in this user guide assume familiarity with the general terminology associated with personal computers

More information

Intel NUC Kit NUC7i3BNHX1 with Intel Optane Memory. Intel NUC Kit NUC7i5BNHX1 with Intel Optane Memory

Intel NUC Kit NUC7i3BNHX1 with Intel Optane Memory. Intel NUC Kit NUC7i5BNHX1 with Intel Optane Memory Intel NUC Kit NUC7i3BNHX1 with Intel Optane Memory Intel NUC Kit NUC7i5BNHX1 with Intel Optane Memory Intel NUC Kit NUC7i7BNHX1 with Intel Optane Memory User Guide 1 Before You Begin CAUTIONS The procedures

More information

Installing the Cisco ADE 2130 and 2140 Series Appliance Hardware Options

Installing the Cisco ADE 2130 and 2140 Series Appliance Hardware Options CHAPTER 4 Installing the Cisco ADE 2130 and 2140 Series Appliance Hardware Options This chapter provides instructions for installing, replacing, and removing various hardware options in your Cisco ADE

More information

Computer Setup (F10) Utility Guide HP Business Desktops dx5150 model

Computer Setup (F10) Utility Guide HP Business Desktops dx5150 model Guide HP Business Desktops dx5150 model Document Part Number: 374172-001 December 2004 This guide provides instructions on how to use Computer Setup. This tool is used to reconfigure and modify computer

More information

SCv3000 and SCv3020 Storage System. Owner s Manual

SCv3000 and SCv3020 Storage System. Owner s Manual SCv3000 and SCv3020 Storage System Owner s Manual Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make better use of your product. CAUTION: A CAUTION indicates

More information

Dell PowerEdge 6 Gbps SAS HBA and Internal Tape Adapter. User s Guide

Dell PowerEdge 6 Gbps SAS HBA and Internal Tape Adapter. User s Guide Dell PowerEdge 6 Gbps SAS HBA and Internal Tape Adapter User s Guide Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make better use of your computer. CAUTION:

More information

Upgrading and Servicing Guide

Upgrading and Servicing Guide Upgrading and Servicing Guide The only warranties for Hewlett-Packard products and services are set forth in the express statements accompanying such products and services. Nothing herein should be construed

More information

User Guide for NUC7i3DNHNC. Intel NUC7 Business, a Mini PC with Windows 10 NUC7i3DNHNC. User Guide

User Guide for NUC7i3DNHNC. Intel NUC7 Business, a Mini PC with Windows 10 NUC7i3DNHNC. User Guide Intel NUC7 Business, a Mini PC with Windows 10 NUC7i3DNHNC User Guide 1 Before You Begin CAUTIONS The steps in this guide assume you re familiar with computer terminology and with the safety practices

More information

RAID-01 (ciss) B Mass Storage Driver Release Notes

RAID-01 (ciss) B Mass Storage Driver Release Notes RAID-01 (ciss) B.11.31.1705 Mass Storage Driver Release Notes HP-UX 11i v3 Abstract This document contains specific information that is intended for users of this HPE product. Part Number: Published:

More information

HP UPS R/T3000 ERM. Overview. Precautions. Installation Instructions

HP UPS R/T3000 ERM. Overview. Precautions. Installation Instructions HP UPS R/T3000 ERM Installation Instructions Overview The ERM consists of two battery packs in a 2U chassis. The ERM connects directly to a UPS R/T3000 or to another ERM. Up to two ERM units can be connected.

More information

Quick Setup & Getting Started Business PCs

Quick Setup & Getting Started Business PCs Quick Setup & Getting Started Business PCs Copyright 2008 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Microsoft, Windows, and Windows

More information

HP Moonshot Switch User and Maintenance Guide

HP Moonshot Switch User and Maintenance Guide HP Moonshot Switch User and Maintenance Guide Abstract This document is for the person who installs, administers, services, and troubleshoots switches. This guide provides identification, setup, installation,

More information

DP SATA 6Gb/s PCIe i/e Quick Installation Guide

DP SATA 6Gb/s PCIe i/e Quick Installation Guide DP SATA 6Gb/s PCIe i/e Quick Installation Guide Introducing the SATA 6Gb/s PCIe i/e The DP SATA 6Gb/s PCIe i/e adds 2 SATA 6Gb/s & a PATA connectors to PCIe-equipped computers. Features and Benefits Dual

More information

StoreOnce 6500 (88TB) System Capacity Expansion Guide

StoreOnce 6500 (88TB) System Capacity Expansion Guide StoreOnce 6500 (88TB) System Capacity Expansion Guide Abstract This document explains how to install the StoreOnce 6500 System Capacity Expansion Kit, apply the new license, and add the new storage to

More information

User Guide. Intel NUC 7 Home, a Mini PC with Windows 10 NUC7i5BNKP. Intel NUC 7 Enthusiast, a Mini PC with Windows 10 NUC7i7BNKQ

User Guide. Intel NUC 7 Home, a Mini PC with Windows 10 NUC7i5BNKP. Intel NUC 7 Enthusiast, a Mini PC with Windows 10 NUC7i7BNKQ Intel NUC 7 Home, a Mini PC with Windows 10 NUC7i5BNKP Intel NUC 7 Enthusiast, a Mini PC with Windows 10 NUC7i7BNKQ User Guide 1 Before You Begin CAUTION The steps in this guide assume you re familiar

More information

User Guide for NUC7CJYSAL. Intel NUC 7 Essential, a Mini PC with Windows 10 NUC7CJYSAL. User Guide

User Guide for NUC7CJYSAL. Intel NUC 7 Essential, a Mini PC with Windows 10 NUC7CJYSAL. User Guide Intel NUC 7 Essential, a Mini PC with Windows 10 NUC7CJYSAL User Guide 1 Before You Begin CAUTIONS The steps in this guide assume you re familiar with computer terminology and with the safety practices

More information

User Guide for NUC7CJYSAL. Intel NUC 7 Essential, a Mini PC with Windows 10 NUC7CJYSAL. User Guide

User Guide for NUC7CJYSAL. Intel NUC 7 Essential, a Mini PC with Windows 10 NUC7CJYSAL. User Guide Intel NUC 7 Essential, a Mini PC with Windows 10 NUC7CJYSAL User Guide 1 Before You Begin CAUTIONS The procedures in this guide assume familiarity with the general terminology associated with personal

More information

Intel NUC Kit NUC6CAYS User Guide

Intel NUC Kit NUC6CAYS User Guide Intel NUC Kit NUC6CAYS User Guide Regulatory Model NUC6CAY 1 Before You Begin CAUTIONS The procedures in this user guide assume familiarity with the general terminology associated with personal computers

More information

HPE ProLiant Gen9 Troubleshooting Guide

HPE ProLiant Gen9 Troubleshooting Guide HPE ProLiant Gen9 Troubleshooting Guide Volume II: Error Messages Abstract This guide provides a list of error messages associated with HPE ProLiant servers, Integrated Lights-Out, Smart Array storage,

More information

Intel NUC7 Home, a Mini PC with Windows 10 NUC7i3BNHXF. Intel NUC7 Home, a Mini PC with Windows 10 NUC7i5BNHXF

Intel NUC7 Home, a Mini PC with Windows 10 NUC7i3BNHXF. Intel NUC7 Home, a Mini PC with Windows 10 NUC7i5BNHXF Intel NUC7 Home, a Mini PC with Windows 10 NUC7i3BNHXF Intel NUC7 Home, a Mini PC with Windows 10 NUC7i5BNHXF Intel NUC7 Enthusiast, a Mini PC with Windows 10 NUC7i7BNHXG User Guide 1 Before You Begin

More information

Getting Started. HP Business PCs

Getting Started. HP Business PCs Getting Started HP Business PCs Copyright 2010 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Microsoft, Windows, Windows Vista, and Windows

More information

Keysight E5864A Removable Hard Drive for Series Logic Analyzers. Installation Guide

Keysight E5864A Removable Hard Drive for Series Logic Analyzers. Installation Guide Keysight E5864A Removable Hard Drive for 16850-Series Logic Analyzers Installation Guide Notices Keysight Technologies 2013-2014 No part of this manual may be reproduced in any form or by any means (including

More information

Before Reading This Manual This section explains the notes for your safety and conventions used in this manual.

Before Reading This Manual This section explains the notes for your safety and conventions used in this manual. Integrated Mirroring SAS User s Guide Areas Covered Before Reading This Manual Chapter 1 Chapter 2 Chapter 3 This section explains the notes for your safety and conventions used in this manual. Overview

More information

HP LaserJet MFP Analog Fax Accessory 300. Supplemental Information

HP LaserJet MFP Analog Fax Accessory 300. Supplemental Information HP LaserJet MFP Analog Fax Accessory 300 Supplemental Information HP LaserJet MFP Analog Fax Accessory 300 Supplemental Information Copyright Information 2005 Copyright Hewlett-Packard Development Company,

More information

Replacing the RAID Battery Backup Unit Assembly on Series 3 FireSIGHT 3500 Defense Centers, Version 5.x

Replacing the RAID Battery Backup Unit Assembly on Series 3 FireSIGHT 3500 Defense Centers, Version 5.x Replacing the RAID Battery Backup Unit Assembly on Series 3 FireSIGHT 3500 Defense Centers, Version 5.x Last Updated: December 4, 2014 Use these instructions to replace the RAID battery backup unit (BBU)

More information

User Guide for NUC8i5BEK, NUC8i3BEK. Intel NUC Kit NUC8i5BEK Intel NUC Kit NUC8i3BEK. User Guide

User Guide for NUC8i5BEK, NUC8i3BEK. Intel NUC Kit NUC8i5BEK Intel NUC Kit NUC8i3BEK. User Guide Intel NUC Kit NUC8i5BEK Intel NUC Kit NUC8i3BEK User Guide 1 Before You Begin CAUTIONS The steps in this guide assume you re familiar with computer terminology and with the safety practices and regulatory

More information

High Density RocketRAID EJ6172 Device Board Data RAID Installation Guide

High Density RocketRAID EJ6172 Device Board Data RAID Installation Guide High Density RocketRAID 2711 + EJ6172 Device Board Data RAID Installation Guide Introduction The HighPoint High Density Storage Solutions hammer down high density storage cost over a single mini- SAS port.

More information

HP Moonshot-45XGc Switch User and Maintenance Guide

HP Moonshot-45XGc Switch User and Maintenance Guide HP Moonshot-45XGc Switch User and Maintenance Guide Abstract This document is for the person who installs, administers, services, and troubleshoots switches. This guide provides identification, setup,

More information

HP ProLiant Moonshot Server User and Maintenance Guide

HP ProLiant Moonshot Server User and Maintenance Guide HP ProLiant Moonshot Server User and Maintenance Guide Abstract This document is for the person who installs, administers, services, and troubleshoots cartridges. This guide describes identification and

More information

Getting Started. HP Business PCs

Getting Started. HP Business PCs Getting Started HP Business PCs Copyright 2013 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Windows is a U.S. registered trademark of

More information

User Guide. Intel NUC 8 Business, a Mini PC with Windows 10 NUC8i7HNKQC. Intel NUC 8 Enthusiast, a Mini PC with Windows 10 NUC8i7HVKVA

User Guide. Intel NUC 8 Business, a Mini PC with Windows 10 NUC8i7HNKQC. Intel NUC 8 Enthusiast, a Mini PC with Windows 10 NUC8i7HVKVA Intel NUC 8 Business, a Mini PC with Windows 10 NUC8i7HNKQC Intel NUC 8 Enthusiast, a Mini PC with Windows 10 NUC8i7HVKVA User Guide 1 Before You Begin CAUTIONS The procedures in this user guide assume

More information

Intel NUC Kit DC53427HYE User Guide. Intel NUC Kit DC53427HYE

Intel NUC Kit DC53427HYE User Guide. Intel NUC Kit DC53427HYE Intel NUC Kit DC53427HYE User Guide 1 Before You Begin CAUTIONS The procedures in this user guide assume familiarity with the general terminology associated with personal computers and with the safety

More information

Quick Setup & Getting Started

Quick Setup & Getting Started Quick Setup & Getting Started HP Compaq Business PC Copyright 2007 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Microsoft, Windows, and

More information

Intel NUC Kit NUC8i7HNK & NUC8i7HVK User Guide. Intel NUC Kit NUC8i7HNK Intel NUC Kit NUC8i7HVK User Guide

Intel NUC Kit NUC8i7HNK & NUC8i7HVK User Guide. Intel NUC Kit NUC8i7HNK Intel NUC Kit NUC8i7HVK User Guide Intel NUC Kit NUC8i7HNK Intel NUC Kit NUC8i7HVK User Guide 1 Before You Begin CAUTIONS The procedures in this user guide assume familiarity with the general terminology associated with personal computers

More information

HP BIOS Serial Console User Guide. Part Number March 2003 (Second Edition)

HP BIOS Serial Console User Guide. Part Number March 2003 (Second Edition) HP BIOS Serial Console User Guide Part Number 306147-002 March 2003 (Second Edition) 2003 Hewlett-Packard Development Company, L.P. Microsoft and Windows are U.S. registered trademarks of Microsoft Corporation.

More information

Hardware Reference Guide. HP Thin Client

Hardware Reference Guide. HP Thin Client Hardware Reference Guide HP Thin Client Copyright information Copyright 2016 HP Development Company, L.P. First Edition: June 2016 Document Part Number: 839088-001 Warranty The information contained herein

More information

QuickSpecs. Models. HP Smart Array P400i Controller. Overview

QuickSpecs. Models. HP Smart Array P400i Controller. Overview Overview The HP Smart Array P400 Serial Attached SCSI (SAS) controller (SA-P400) provides new levels of performance and reliability for HP servers, through its support of the latest SCSI technology and

More information

QuickSpecs. What's New. Models. Overview

QuickSpecs. What's New. Models. Overview Overview The HP Smart Array P400 is HP's first PCI-Express (PCIe) serial attached SCSI (SAS) RAID controller and provides new levels of performance and reliability for HP servers, through its support of

More information

High Density RocketRAID Rocket EJ240 Device Board Data RAID Installation Guide

High Density RocketRAID Rocket EJ240 Device Board Data RAID Installation Guide High Density RocketRAID 2711 + Rocket EJ240 Device Board Data RAID Installation Guide Introduction The HighPoint High Density Storage Solutions hammer down high density storage cost over a single mini-

More information

Power. Document Part Number: This guide explains how the computer uses power. December 2005

Power. Document Part Number: This guide explains how the computer uses power. December 2005 Power Document Part Number: 393525-002 December 2005 This guide explains how the computer uses power. Contents 1 Power controls and lights 2 Power sources Connecting the AC adapter.......................

More information

User Guide. Intel NUC7 Home, a Mini PC with Windows 10 NUC7i5BNKP. Intel NUC7 Enthusiast, a Mini PC with Windows 10 NUC7i7BNKQ

User Guide. Intel NUC7 Home, a Mini PC with Windows 10 NUC7i5BNKP. Intel NUC7 Enthusiast, a Mini PC with Windows 10 NUC7i7BNKQ Intel NUC7 Home, a Mini PC with Windows 10 NUC7i5BNKP Intel NUC7 Enthusiast, a Mini PC with Windows 10 NUC7i7BNKQ User Guide 1 Before You Begin CAUTION The procedures in this guide assume familiarity with

More information

QuickSpecs. HPE Integrity Smart Array P411/256 2-port External PCIe 6Gb SAS Controller. Overview. What's New Boot from Tape

QuickSpecs. HPE Integrity Smart Array P411/256 2-port External PCIe 6Gb SAS Controller. Overview. What's New Boot from Tape HPE Integrity Smart Array P411/256MB 2-Port External PCIe 6Gb SAS Overview The HPE Smart Array P411 is HPE's external connect only, PCI Express (PCIe) 2.0 Serial Attached SCSI (SAS) RAID controller for

More information

Copyright 2007 Hewlett-Packard Development Company, L.P.

Copyright 2007 Hewlett-Packard Development Company, L.P. Drives User Guide Copyright 2007 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. The only warranties for HP products and services are set

More information

Power. Document Part Number: This guide explains how the computer uses power. March 2006

Power. Document Part Number: This guide explains how the computer uses power. March 2006 Power Document Part Number: 396855-001 March 2006 This guide explains how the computer uses power. Contents 1 Power control and light locations 2 Power sources Connecting the AC adapter....................

More information

Getting Started. HP Business PCs

Getting Started. HP Business PCs Getting Started HP Business PCs Copyright 2010, 2012-2014, 2016 HP Development Company, L.P. Windows is a registered trademark or trademark of Microsoft Corporation in the United States and/or other countries.

More information

Upgrading and Servicing Guide

Upgrading and Servicing Guide Upgrading and Servicing Guide The information in this document is subject to change without notice. Hewlett-Packard Company makes no warranty of any kind with regard to this material, including, but not

More information

HP StoreOnce 4900 (44TB) and (60TB) Capacity Expansion Kit

HP StoreOnce 4900 (44TB) and (60TB) Capacity Expansion Kit HP StoreOnce 4900 (44TB) and (60TB) Capacity Expansion Kit Installation Instructions Abstract This document explains how to install the HP StoreOnce 4900 (44TB) and (60TB) Capacity Expansion Kit, apply

More information

Veritas Appliance Hardware Service Procedure

Veritas Appliance Hardware Service Procedure Veritas Appliance Hardware Service Procedure Replacing a RAID Controller in a Veritas 5U84 Primary Storage Shelf Document Number: 217 Version: 1.0 (11/06/17) Purpose This document describes the process

More information

User Guide. Intel NUC 8 Enthusiast, a Mini PC with Windows 10 NUC8i7BEKQA. Intel NUC 8 Home, a Mini PC with Windows 10 NUC8i5BEKPA

User Guide. Intel NUC 8 Enthusiast, a Mini PC with Windows 10 NUC8i7BEKQA. Intel NUC 8 Home, a Mini PC with Windows 10 NUC8i5BEKPA Intel NUC 8 Enthusiast, a Mini PC with Windows 10 NUC8i7BEKQA Intel NUC 8 Home, a Mini PC with Windows 10 NUC8i5BEKPA User Guide 1 Before You Begin CAUTIONS The steps in this guide assume you re familiar

More information

Models Smart Array 6402/128 Controller B21 Smart Array 6404/256 Controller B21

Models Smart Array 6402/128 Controller B21 Smart Array 6404/256 Controller B21 Overview The Smart Array 6400 high performance Ultra320, PCI-X controller family provides maximum performance, flexibility, and reliable data protection for HP ProLiant servers, through its unique modular

More information

Dell Host Bus Adaptor User s Guide

Dell Host Bus Adaptor User s Guide Dell Host Bus Adaptor User s Guide Regulatory Model: UCSE 900 Notes, cautions, and warnings NOTE: A NOTE indicates important information that helps you make better use of your product. CAUTION: A CAUTION

More information

Dell SCv3000 and SCv3020 Storage System Owner s Manual

Dell SCv3000 and SCv3020 Storage System Owner s Manual Dell SCv3000 and SCv3020 Storage System Owner s Manual Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make better use of your product. CAUTION: A CAUTION indicates

More information

hp uninterruptible power system r12000 xr models installation instructions

hp uninterruptible power system r12000 xr models installation instructions hp uninterruptible power system r000 xr models installation instructions Overview These instructions show how to install an uninterruptible power system (UPS). For detailed information about the UPS, refer

More information

HP ProLiant DL380 Generation 4 Server Maintenance and Service Guide

HP ProLiant DL380 Generation 4 Server Maintenance and Service Guide HP ProLiant DL380 Generation 4 Server Maintenance and Service Guide March 2006 (Seventh Edition) Part Number 359226-007 Copyright 2004, 2006 Hewlett-Packard Development Company, L.P. The information contained

More information

HP UPS R/T3000 G2. Overview. Precautions. Kit contents. Installation Instructions

HP UPS R/T3000 G2. Overview. Precautions. Kit contents. Installation Instructions HP UPS R/T3000 G2 Installation Instructions Overview The HP UPS R/T3000 G2 features a 2U rack-mount with convertible tower design and offers power protection for loads up to a maximum of 3300 VA/3000 W

More information

Dell SC7020 and SC7020F Storage Systems Owner s Manual

Dell SC7020 and SC7020F Storage Systems Owner s Manual Dell SC7020 and SC7020F Storage Systems Owner s Manual Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make better use of your computer. CAUTION: A CAUTION indicates

More information

Serial ATA Hot Swap Drive Cage Upgrade Kit for: Intel Server Chassis SC5200 Intel Server Chassis SC5250-E

Serial ATA Hot Swap Drive Cage Upgrade Kit for: Intel Server Chassis SC5200 Intel Server Chassis SC5250-E Serial ATA Hot Swap Drive Cage Upgrade Kit for: Intel Server Chassis SC5200 Intel Server Chassis SC5250-E A Guide for Technically Qualified Assemblers of Intel Identified Subassemblies/Products Order Number:

More information