The industry standard for sequential events recording Proven, reliable and easy to use

Size: px
Start display at page:

Download "The industry standard for sequential events recording Proven, reliable and easy to use"

Transcription

1 SER 4100 Events Recording System The industry standard for sequential events recording Proven, reliable and easy to use T he SER 4100 events recording system is a versatile high speed distributed microprocessor-based data acquisition system designed to monitor and record, in real time, changes of state of cutomer supplied field inputs with an accuracy of one millisecond. The SER 4100 Events Recording System With flexible configuration and up to seven EIA-232 serial ports available, communications to a wide range of peripheral devices can be achieved. Multiple devices for printing, displaying and storage of data can be supported simultaneously. The SER 4100 has a building block design and versatile communication features in order to accommodate a wide range of capacity and configuration requirements. Its capacity ranges in 64 point increments (one input card) from a maximum of 512 points for a single chassis system to as many as 4096 points for a system consisting of a main chassis and any number of expansion chassis (maximum 64 chassis) from 64 to 512 points. These can be located locally or up to one mile (1.6km) away, affording tremendous configuration flexibility. Whatever your application, the industry standard SER 4100 can meet your needs. The SER 4100 Events Recording System: Is a reliable source of time-stamped events data for analysis Is easy to program and use Has a unique variable debounce filter system Has distributed sequential memory storage Has seven I/O ports enabling communication flexibility Maintains system reliability and security Can combine events recording with annunciation Automation made easy

2 A reliable source of time-stamped events data for analysis The SER 4100 is a complete events recording system for medium to large scale plant monitoring applications. Its extensive communications facilities make it especially valuable as front end instrumentation for reducing burden on the main control systems computer. Easy to program and use Programming and operating the SER4100 is simple. All communications are achieved by means of a keyboard terminal device for equipment configuration and operator reports At the same time, the SER 4100 serves as the control rooms indication and recording source for ongoing events data. The system is designed in building block fashion for configuring the required capacity with room for future expansion. A system can consist in size from one 64 point chassis up to sixty four chassis totaling a maximum of 4096 points. The chassis can be grouped together in a single place or located remotely, up to one mile (1.6km) from each other when installed in series via duplex fiber optic interconnecting cables. A maximum of sixty-four remote chassis may be used in sizes from 64 to 512 points for a maximum system size of 4096 points providing a wide range of remote scanning possibilities. In addition to the point number, type of event, and time information, each point can be assigned a 60 character, alphanumeric legend (optionally expandable to 60 additional characters for return-to-normal legends). The following is a typical event printout: A 16: 14: #098 CONDENSER LEVEL HIGH N: 16: 15: #098 CONDENSER LEVEL HIGH This example states that at 14 minutes, seconds after 1600 hours (4pm), point number 98 went into an alarm condition. Then at 15 minutes, seconds after the hour, point 98 returned to normal. The legend for point 98 is CONDENSER LEVEL HIGH. Return-to-normal data is indented two spaces. Programming can also be done through one or more of the EIA- 232 ports from any standard terminal device. Using the keyboard, the following system parameters can be set or changed: N. O./ N. C. field contacts Alarm input debounce filter Return-to-normal debounce filter Point enable/disable 60 character legends with editing EIA- 232 ports, fully configurable for type of device, baud rate, and parity Point assignments to EIA- 232 ports Eight special function configurable relay outputs Initial time set or correction and date input Auto delete/restore from log parameters. A unique variable debounce filter system The SER 4100 features a unique variable debounce filter system to filter out input noise, prevent nuisance alarms, and allow for relay contact bounce. It is provided by a digital input filter (alarm debounce), adjustable from the keyboard on a single point or group of points basis from one millisecond to 65 seconds. It is also available to debounce a return-to-normal on a per- point basis. Distributed sequential memory storage The SER 4100s distributed sequential memory is capable of storing over 4500 event messages per 64 points on each scanner card. The distribution of memory on separate scanner cards in 64 point increments ensures that the failure of individual cards will not destroy the systems entirememory bank. The SER 4100 features event storage for analysis purposes in the form of a circular historical buffer, whose design is unique in events recording instrumentation. It stores the last 6000 events captured, which can be easily accessed for post fault analysis. By using a keyboard entry, events can be recalled by date, time or address, or by events occurring since the last request, which is particularly useful in unmanned applications. In addition to its external point capacity, the SER 4100 offers eight synthesized or OR points (a synthesized point is an internally generated point driven by one or more inputs assigned to that point, or from one or more internal diagnostic points). Typically, synthesized points can be used to output diagnostic failures, to retransmit a point or a group of points, to provide output to a horn, or in any other application requiring an output related to a single input point or group of points.

3 Seven I/ O Ports enable communication flexibility The real value of the SER 4100 lies in its extensive facilities for communicating with a true diversity of other instrumentation. Paramount is its ability to provide relief for a main control computer, which makes it a valuable front end device. The SER 4100 saves the computer from having to perform events scanning, a function computers are not well suited for, particularly during system upsets and other high-volume event conditions. In all, there are six different EIA-232 output ports available on the SER 4100, with a seventh port configured to accept an IRIG- B clock synchronization input. The EIA-232 inputs provide compatibility for receiving inputs from and/or outputting events data to all of the following: Color CRT displays and serial input window annunciators Printers Printer terminals Various modems (long haul/short haul) Computers Distributed process control systems Programmable controllers GPS satellite receivers (time syncs). The SER 4100 can run output devices at selectable baud rates, data bits and parity checks. Maintain system reliability and security In developing the SER 4100, Qualitrol has paid careful attentionto the kind of details necessary to fully protect the integrity of events data. Self-diagnostics enhance troubleshooting procedures, system or module failure codes are presented on both printer and CRT displays to prompt maintenance personnel. An hourly functional automatic test (including printout) fully exercises the system from input circuit forward. The system crystal controlled clock can be synchronized to the AC line, hourly input pulse, IRIG- B, or satellite receiver. There is battery back-up for both date and time and historical buffer. A programmable security code is available to limit access to the system. Combine events recording with annunciation While the SER 4100 is a system unto itself, it can also be used in conjunction with two types of annunciators. Either combination forms a powerful and complete system of events recording and visual audible annunciation. A color CRT annunciator can be supplied for displaying selected events in color on a screen. Up to 20 events can be presented, with provisions for additional events to be stored in pages of memory. The 60 character legend descriptions can be color-coded in any of eight standard colors. The time field for new alarms appears in a flashing red mode, acknowledged alarms change to a steady yellow, and return-tonormal events are displayed in green. Where window annunciation is required, the 4100 can serve as the scanning source for the Betalarm 1500 serial input distributed annunciator. Several different system levels are available. The diagrams below show typical SER/ 1500 annunciator configurations. Many other configurations are available, depending upon customer requirements.

4 SER 4100 Operator Initiated Reports Functional Test (FT) Initiated by the operator, or automatically every hour. Verifies that all active inputs are being processed and accepted by the input logic. Any input not responding to the test signal in the alarm or normal state will be printed as faulty. Alarm Summary (AS) Prints out all point currently in alarm status. Historical Display (LH) Allows the operator access to the memory block containing the most recent 6000 events. Historical Display Since Last Update (LU) Similar to LH report but lists only the contents of the buffer since the last LU report was requested. List Status (LS) Lists on a per point basis the normally ope/closed status, alarm and return debounce filter times, whether or not the point is enabled, if the point is designated as critical and auto delete/ restore from log parameters. List Exception (LE) Prints out all points that have beenoperator disabled by use of the MS command. List Legends (LL) Reports the legend data stored in battery backed RAM. List Configuration (LC) Prints out the seven port configurations, the status of each of the scanner cards, Alarm or Normal indentation, whether or not the optional battery- backed RAM is implemented and the number of points in the system. List Output Assignments (LO) Lists input point assignments to output devices for each of the six EIA- 232 ports. List Synthesized Points (LP) Reports the status of any or all of the synthesized points A through H. This consists of the point mode and whether the given relay is enabled or disabled. Optional equipment and features: SER 4100 Events Recording System Features and Options Color CRT display Satellite clock synchronization IRIG-B clock synchronization Remote Configuration workstation software Terminal inputs and outputs Configuration terminal 80 column printer (available in two colors) RTN legends, 60 characters 0.1ppm clock accuracy

5 Technical Specifications Power Supply Input power: Field contact power supply: Vac, 50/60Hz Vdc 48Vdc 24Vdc. 250Vdc 125Vdc 48Vdc 24Vdc (internally supplied). Customer supplied external field contact power supply input option (ranges as per internal selection). Performance Communication Ports Configuration Immunity Environmental Mechanical Maximum point capability: Maximum separation distance: Sequential memory capability: Historical memory capability: Auxiliary relay outputs: EIA-232 ports 3 standard, 3 optional: Software adjustable parameters: Single chassis 512 points total in increments of 64 (eight 64 point cards) Multiple chassis, (maximum of sixty four chassis) up to a point count of 4096 (in multiples of 64 point cards). Between chassi s, 1 mile (1.6km). >4500 event messages per 64 points. Circular buffer with 6000 point event storage. 8 available rated at 0.5A at 120Vac or 2A at 30Vdc. Clock synchronization: 50/60 Hz External sync pulse, once per hour IRIG-B. Scan time: 10μs or less. Resolution: Clock accuracy: EIA-232 equipment compatibility: Operator initiated reports: 1ms. Standard 25ppm. Optional 0.1ppm. One port fixed for configuration, including use of Remote Configuration workstation software. One port fixed for clock synchronization: Satellite clock synchronization IRIG B clock synchronization. All other ports are user selectable for supporting EIA-232 equipment compatibility. Compatible equipment: Color CRT display Configuration terminals, including Remote Configuration workstation software Printers, including 80 column printer (available in two colors) Various modems (long/short haul) Computers Serial input window annunciators Distributed control systems Programmable controllers GPS receivers (time sync). Via keyboard initiated commands: N.O./N.C. field contacts Alarm input time delay Return-to-normal time delay Point enable/disable 60 character legends with editing EIA-232 output ports, fully configurable for device type, baud rate, and parity Point assignments to EIA-232 ports Eight configurable relay outputs Time set/correction and date input Oscillatory inputs defined. Point configuration report System configuration report Output port assignment report Full historical buffer report Historical buffer update report Point delete report Alarm summary report Functional test report List legend report. Input isolation: Point input protected by a 1500V rated optical coupler input to output. SWC: Surge withstand capability to ANSI C37 90a, IEEE 472 and IEC Operating temperature: Humidity: Compatibility: Enclosure: O to 50 C (32 to 122 F). O to 95% non-condensing. Meets current RFI/EMI standard. 8U, 19 rack mountable chassis. Meets EIA-310-B requirements. Dimensions: Width: 482.6mm (19 ). Depth: 406.4mm (16 ). Height: 352.4mm (13.87 ). Weight: Terminals: Cabinets/cubicles: Approx. 13.6kg (30lbs). Field inputs via 37 pin D-shell connectors. Can be cabled to supplied input terminals, optional 64-point terminal panels or terminal rail assemblies. Standard and customer specific cabinet/cubicle enclosures available. SER 4100 Events Recording System

6 SER 4100 Events Recording System Ordering Information The SER 4100 system consists of a main chassis equipped with a Main Controller Module and optional Auxiliary or Communications Controller Modules. Additional scanner scanner slots in the main chassis can accomodate Input Scanner Modules, Annunciator Output Modules or Fiber Optic Multiplexer Modules and Expansion Chassis may be incorporated when additional slots are required. Three types of chassis are available: The 4100F (full-size chassis) with eight additional slots The 4100S(slimline) chassis with two additional slots The 4100R (redundant chassis) that provides eight slots for Input or Output Modules but also accommodates redundant controller modules. Asia Pacific Qualitrol Singapore 246 MacPherson Road #08-01 Betime Building Singapore Europe Qualitrol GmbH Willstaetterstrasse Duesseldorf Germany Latin America Paseo De Echegarar #18A Fraccionamiento La Florida Naucalpan, Estado de Mexico Mexico North America Qualitrol Corporation 1385 Fairport Road Fairport, NY USA Worldwide Sales Offices Phone: ext. 21 Fax : Phone: +49 (0) Fax: +49 (0) Phone: Fax: Phone: Fax Orders: Fax Quotes: info@qualitrolcorp.com Qualitrol 2004 Qualitrol Corporation is aniso 9001 system certified company. QSB SER 4100, 2/04. All trademarks and registered trademarks are properties of their respective companies and are hereby acknowlegeded. Information subject to change without notice.

Mehta Tech, Inc. TRANSCAN IED For Multi-Function, Multi-Speed Recording

Mehta Tech, Inc. TRANSCAN IED For Multi-Function, Multi-Speed Recording Mehta Tech, Inc. TRANSCAN IED For Multi-Function, Multi-Speed Recording Two independent, simultaneously operating recorders in one package Triggering on input quantities and calculated values, such as

More information

M-series DeltaV Controller Interface for PROVOX I/O

M-series DeltaV Controller Interface for PROVOX I/O January 2013 Page 1 M-series DeltaV Controller Interface for PROVOX I/O PROVOX I/O Interface Modules DeltaV Railbus C Control I/O Bus with Redundant Connections Upgrade your PROVOX controllers with the

More information

NTX Series Product Comparison

NTX Series Product Comparison NTX Function Primary design application Pole-top/pad-mount switch automation; small substation installations Small substation installations with medium serial and Ethernet port requirements Some legacy

More information

VCL-TP, Teleprotection Equipment

VCL-TP, Teleprotection Equipment VCL-TP, Teleprotection Equipment Data Sheet Copyright: Valiant Communications Limited. - 2013 1 Product Overview VCL-TP, Teleprotection Equipment is an extremely reliable and flexible product that offers

More information

VCL-TP, Teleprotection Equipment With Trip Counter Display Panel

VCL-TP, Teleprotection Equipment With Trip Counter Display Panel VCL-TP, Teleprotection Equipment With Trip Counter Display Panel Data Sheet Copyright: Valiant Communications Limited. 2008-2014 1 Product Overview VCL-TP, Teleprotection Equipment is an extremely reliable

More information

LTC 8600 Series Allegiant Matrix/Control Systems - Modular

LTC 8600 Series Allegiant Matrix/Control Systems - Modular CCTV LTC 86 Series Allegiant Matrix/Control Systems - Modular LTC 86 Series Allegiant Matrix/Control Systems - Modular 128 Camera by 16 monitor switching Modular construction Powerful alarm handling capabilities

More information

LTC 8600 Series Allegiant Matrix/Control Systems - Modular

LTC 8600 Series Allegiant Matrix/Control Systems - Modular CCTV LTC 86 Series Allegiant Matrix/Control Systems - Modular LTC 86 Series Allegiant Matrix/Control Systems - Modular 128 Camera by 16 monitor switching Modular construction Powerful alarm handling capabilities

More information

Advant OCS. The Compact and Cost Effective Advant Controller. Advant Controller 210. Open Control System

Advant OCS. The Compact and Cost Effective Advant Controller. Advant Controller 210. Open Control System Advant OCS Open Control System Advant Controller 210 The Compact and Cost Effective Advant Controller Advant Controller 210 is a small, cost-effective system belonging to the Advant Controller family.

More information

S-series Sequence of Events Card

S-series Sequence of Events Card DeltaV Distributed Control Systems Product Data Sheet S-series Sequence of Events Card DeltaV Sequence of Events delivers high-resolution data capture for your easy analysis. Captures process upset events

More information

Optimux-34 Fiber Optic Multiplexer

Optimux-34 Fiber Optic Multiplexer Data Sheet Optimux-34 Multiple E1, Ethernet, or High-speed Data over E3 or Fiber, up to 110 km (68 miles) Up to 16 E1 links, high-speed data, and Ethernet traffic multiplexed into one E3 copper or fiber

More information

S e q u e n c e O f E v e n t s R e c o r d e r. Monitoring for the Power Generation, Power Distribution, and Process Industries

S e q u e n c e O f E v e n t s R e c o r d e r. Monitoring for the Power Generation, Power Distribution, and Process Industries S e q u e n c e O f E v e n t s R e c o r d e r Monitoring for the Power Generation, Power Distribution, and Process Industries M o d e l X 5 0 0 F S e q u e n c e O f E v e n t s R e c o r d e r The new

More information

I/A Series Hardware 50 Series Application Workstation Processor AW51, Style C

I/A Series Hardware 50 Series Application Workstation Processor AW51, Style C I/A Series Hardware 50 Series Application Workstation Processor AW51, Style C PSS 21H-4R5 B4 The Application Workstation 51 (AW51) Style C Processor in conjunction with its peripherals performs both application

More information

S-Series DeltaV Controller Interface for PROVOX I/O

S-Series DeltaV Controller Interface for PROVOX I/O DeltaV Distributed Control System Product Data Sheet S-Series DeltaV Controller Interface for PROVOX I/O The S-Series DeltaV Controller Interface for PROVOX I/O. I Provides a fast and easy upgrade for

More information

Signamax Connectivity Systems

Signamax Connectivity Systems Signamax Connectivity Systems Hardened Ethernet Switch Model -065-7405TB 065-7408ATB 065-74091FXSTTB 065-74091FXSCTB U S E R S G U I D E 1 Quick Start Guide Hardened Ethernet Switch This quick start guide

More information

Optimux-34, Optimux-25

Optimux-34, Optimux-25 Data Sheet Optimux-34, Optimux-25 16-Channel E1/T1, Ethernet or Data over E3 or Fiber Multiplexers Up to 16 E1/T1 links and high-speed data or Ethernet traffic multiplexed into fiber opt7ic uplink E3 copper

More information

Accessory Packages for the Allegiant

Accessory Packages for the Allegiant CCTV Accessory Packages for the Allegiant Accessory Packages for the Allegiant The Allegiant accessory products provide many optional features to the base Allegiant Video Switcher/Control System. Various

More information

Hardened PoE Ethernet Switch

Hardened PoE Ethernet Switch Quick Start Guide This quick start guide describes how to install and use the Hardened PoE Ethernet Switch. This is the switch of choice for harsh environments constrained by space. Physical Description

More information

A.1 Cisco ONS CL Shelf Specifications. This section includes hardware and software specifications.

A.1 Cisco ONS CL Shelf Specifications. This section includes hardware and software specifications. APPENDIX A Note The terms "Unidirectional Path Switched Ring" and "UPSR" may appear in Cisco literature. These terms do not refer to using Cisco ONS 15xxx products in a unidirectional path switched ring

More information

I/A Series Remote Terminal Unit (RTU) RTU 20 for Oil, Gas, and Water SCADA Applications

I/A Series Remote Terminal Unit (RTU) RTU 20 for Oil, Gas, and Water SCADA Applications I/A Series Remote Terminal Unit (RTU) RTU 20 for Oil, Gas, and Water SCADA Applications RTU 20 OVERVIEW The I/A Series RTU 20 is an Intelligent Remote Device capable of performing a full range of control

More information

FOMi-40 Fiber Optic Modem with Remote Management

FOMi-40 Fiber Optic Modem with Remote Management Data Sheet FOMi-40 Provides a secure and long-range data link of up to 100 km (62 mi) Selectable data rates from 56 to 2048 kbps Multimode or single mode operation Extended transmission range up to 100

More information

PROGRAMMABLE MARQUEE DISPLAYS

PROGRAMMABLE MARQUEE DISPLAYS PROGRAMMABLE MARQUEE DISPLAYS INTRODUCTION: AVG Uticor Marquees can be found in numerous applications throughout all industries. In 1996, a CONTROL ENGINEERING Magazine study named the AVG Uticor brand

More information

S-series Electronic Marshalling for Migrations

S-series Electronic Marshalling for Migrations March 2013 Page 1 S-series Electronic Marshalling for Migrations S-series CHARM I/O Cards (CIOC) mounted on a Migration Panel S-series CHARM I/O Baseplate Migration Panel. I/O anywhere you need it Single

More information

F2238A and F2245A Fiber-Optic EIA-530/MIL-STD Modem Technical Manual

F2238A and F2245A Fiber-Optic EIA-530/MIL-STD Modem Technical Manual F2238A and F2245A Fiber-Optic EIA-530/MIL-STD-188-114 Modem Technical Manual Revision C October 2013 VERSITRON, Inc. 83 Albe Drive / Suite C Newark, DE 19702 www.versitron.com PROPRIETARY DATA All data

More information

Gmux Modular TDMoIP Gateway FEATURES

Gmux Modular TDMoIP Gateway FEATURES FEATURES Carrier-class modular TDMoIP gateway, extending high capacity TDM traffic over packet-switched networks (PSNs) Operates opposite other members of RAD s TDMoIP family of products, offering a complete

More information

PROGRAMMABLE MESSAGE DISPLAYS

PROGRAMMABLE MESSAGE DISPLAYS PROGRAMMABLE MESSAGE DISPLAYS AVG UTICOR Programmable Message Displays (PMDs), are found in numerous applications throughout all industries. PMDs are extremely versatile products, enabling your PLC or

More information

Main Options. Synchronisation source: Satellite (GPS) Terrestrial Low Frequency (MSF, DCF77, WWVB, etc) Timecode (IRIG, AFNOR, etc)

Main Options. Synchronisation source: Satellite (GPS) Terrestrial Low Frequency (MSF, DCF77, WWVB, etc) Timecode (IRIG, AFNOR, etc) M210 Modular Timing System The M210 is a highly flexible timing system designed for use in any applications where reliable time information is required. It is ideal where synchronisation of different output

More information

SM100. On-Line Switchgear Condition Monitoring

SM100. On-Line Switchgear Condition Monitoring On-Line Switchgear Condition Monitoring On-Line Switchgear Condition Monitoring Introduction Weis is a specialist company with over 40 years of experience in the commissioning, testing & maintenance of

More information

S-Band Redundant LNA Systems

S-Band Redundant LNA Systems S-Band Redundant LNA Systems LRS-1000 Series Introduction Redundant LNA systems minimize system downtime due to LNA failure by providing a spare LNA and an automatic means of switching to the spare upon

More information

Modular E1 or Fractional E1 Access Unit. Dial-out for alarm report The E1 main link can be supplied with the following options:

Modular E1 or Fractional E1 Access Unit. Dial-out for alarm report The E1 main link can be supplied with the following options: FEATURES E1 or Fractional E1 access unit Supports one data port with selectable sync data rates: n x 56, n x 64 kbps Optional sub-e1 drop & insert port for PABX connectivity Single slot supports MEGAPLEX

More information

VCL-TP, Teleprotection Equipment with Trip Counter Display

VCL-TP, Teleprotection Equipment with Trip Counter Display ORION TELECOM NETWORKS INC. VCL-TP, Teleprotection Equipment with Trip Counter Display Data Sheet Headquarters: Phoenix, Arizona Orion Telecom Networks Inc. 20100, N 51st Ave, Suite B240, Glendale AZ 85308

More information

Data communication and reporting unit

Data communication and reporting unit SRIO 500M Data communication and reporting unit User s manual and Technical description SRIO 500M FAULT ON 1 2 SERIAL IF 4 LOCAL 1 2 3 4 5 6 7 8 1 0 0542A 1MRS 750540-MUM EN Issued 1996-10-23 Modified

More information

FL MC 2000E (SM40) LC

FL MC 2000E (SM40) LC IEC 61850 fiber optic converter with LC fiber optic connection (1310 nm) to convert 100Base-Tx to single- or multi-mode fiber glass Data sheet 3205_en_C 1 Description PHOENIX CONTACT 2014-04-04 2 Features

More information

XPress-Pro SW User Guide

XPress-Pro SW User Guide XPress-Pro SW 92000 User Guide Part Number 900-505 Revision A May 2007 Copyright & Trademark Contacts 2005, Lantronix. All rights reserved. No part of the contents of this book may be transmitted or reproduced

More information

S-series Sequence of Events Card

S-series Sequence of Events Card March 2013 Page 1 DeltaV Sequence of Events delivers high-resolution data capture for your easy analysis. Captures process upset events close to the source for precise recording Provides increased resolution

More information

IES User Manual. 8 FE + 1 MM SC Unmanaged Switch -40 to 75, DIN-rail. v

IES User Manual. 8 FE + 1 MM SC Unmanaged Switch -40 to 75, DIN-rail. v IES-0920 8 FE + 1 MM SC Unmanaged Switch -40 to 75, DIN-rail User Manual v1.00-1206 Preface This manual describes how to install and use the Industrial Ethernet Switch. This switch integrates full wire

More information

3500/22M Transient Data Interface

3500/22M Transient Data Interface Specifications and Ordering Information 3500/22M Transient Data Interface Description The 3500 Transient Data Interface (TDI) is the interface between the 3500 monitoring system and Bently Nevada s System

More information

VXrouters. The worlds first fiber optic, non-blocking, 6.25 Gbps Video and Peripheral Router! VX Router Series.

VXrouters. The worlds first fiber optic, non-blocking, 6.25 Gbps Video and Peripheral Router! VX Router Series. VX Router Series VXrouters The worlds first fiber optic, non-blocking, 6.25 Gbps Video and Peripheral Router! Thinklogical s exceptionally resilient VX routers switch virtually any desktop device. Unlike

More information

Rugged MediaConverter

Rugged MediaConverter Rugged MediaConverter Installation Guide RuggedCom Inc. 30 Whitmore Road, Woodbridge, Ontario Canada L4L 7Z4 Web: http://www.ruggedcom.com/ Tel: (905) 856-5288 Fax: (905) 856-1995 Toll Free: (888) 264-0006

More information

DeltaV Electronic Marshalling for Migrations

DeltaV Electronic Marshalling for Migrations DeltaV Distributed Control System Product Data Sheet DeltaV Electronic Marshalling for Migrations I/O anywhere you need it Single channel granularity Replaces legacy I/O in place Fully redundant architecture

More information

3 Uninterruptible Power Systems

3 Uninterruptible Power Systems S5K Modular Series On-Line Uninterruptible Power s (UPS) This easily upgraded and flexible UPS provides the protection you want, when you need it. The 5K Modular is scalable from 4 to 20 kva, offering

More information

Installing the IPS 4345 and IPS 4360

Installing the IPS 4345 and IPS 4360 CHAPTER 4 Installing the IPS 4345 and IPS 4360 Contents This chapter describes the Cisco IPS 4345 and the IPS 4360, and includes the following sections: Installation Notes and Caveats, page 4-1 Product

More information

ICS Regent. Monitored Digital Input Modules 24 VDC (T3411) PD-6031

ICS Regent. Monitored Digital Input Modules 24 VDC (T3411) PD-6031 ICS Regent PD-6031 Monitored Digital Input Modules 24 VDC (T3411) Issue 1, March, 06 Monitored digital input modules provide input sensing for 16 field input devices. With a line monitor device installed

More information

Data communication and reporting unit

Data communication and reporting unit FAULT SRIO 1000M Data communication and reporting unit User s manual and Technical description SRIO 1000M ON 1 2 SERIAL IF 4 LOCAL 1 2 3 4 5 6 7 8 1 0 0543A 1MRS 750533-MUM EN Issued 1996-10-23 Modified

More information

3500/22M Transient Data Interface Bently Nevada* Asset Condition Monitoring

3500/22M Transient Data Interface Bently Nevada* Asset Condition Monitoring 3500/22M Transient Data Interface Bently Nevada* Asset Condition Monitoring Description The 3500 Transient Data Interface (TDI) is the interface between the 3500 monitoring system and GE s System 1* machinery

More information

Dell SC5020 and SC5020F Storage Systems Getting Started Guide

Dell SC5020 and SC5020F Storage Systems Getting Started Guide Dell SC5020 and SC5020F Storage Systems Getting Started Guide Regulatory Model: E03T Regulatory Type: E03T001 Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make

More information

ASMi-52. 2/4-Wire SHDSL Modem FEATURES

ASMi-52. 2/4-Wire SHDSL Modem FEATURES FEATURES Dedicated managed SHDSL modem Operates over 2-wire and 4-wire lines, enabling service over any copper infrastructure Multiplexes of two data streams (E1, Ethernet, Serial) over SHDSL Utilizes

More information

114FX6. Phone: Fax: Web: -

114FX6. Phone: Fax: Web:  - THE INDUSTRIAL NETWORK COMPANY 114FX6 PRODUCT FEATURES Compact, Space Saving Package Full IEEE 802.3 Compliance Eight 10/100BaseTX RJ-45 Ports Six 100BaseFX Ports, ST or SC Style Unmanaged Operation Extended

More information

RT4F-120V/20A-WAC RECTIFIER

RT4F-120V/20A-WAC RECTIFIER The RT4F-120V/20A-WAC is a switched mode rectifier/charger module designed to provide up to 20A of output current into a 120V nominal system. This charger has been designed for use in conjunction with

More information

Power Panel. Terminal block, 12 pin, 20 pcs., cage clamps. Table 5: Order data for PP41

Power Panel. Terminal block, 12 pin, 20 pcs., cage clamps. Table 5: Order data for PP41 6. 6.1 Order Data Model Number 4P3040.00-490 1) 0AC201.9 0MC111.9 0MC211.9 4A0034.00-000 4EX101.00 7TB712.9 7TB712.91 7TB712:90-02 7TB712:91-02 Short Description, 5.7 inch QVGA black/white LC display,

More information

Multi-Point Gas Detection and Control System

Multi-Point Gas Detection and Control System Multi-Point Gas Detection and Control System Specifications subject to change without notice. USA 40804 Page of 7 DESCRIPTION Wall mounted, microprocessor-based, multi-point, analog electronic control

More information

3 Uninterruptible Power Systems

3 Uninterruptible Power Systems S5K Modular Series Uninterruptible Power Systems (UPS) This easily upgraded and flexible UPS provides the protection you want, when you need it. The 5K Modular is scalable from 4 to 20 kva, offering many

More information

Dell Storage Center. Getting Started Guide. SCv2000 and SCv2020 Storage System. Regulatory Model: E09J, E10J Regulatory Type: E09J001, E10J001

Dell Storage Center. Getting Started Guide. SCv2000 and SCv2020 Storage System. Regulatory Model: E09J, E10J Regulatory Type: E09J001, E10J001 Dell Storage Center SCv2000 and SCv2020 Storage System Getting Started Guide Regulatory Model: E09J, E10J Regulatory Type: E09J001, E10J001 Notes, Cautions, and Warnings NOTE: A NOTE indicates important

More information

Optimux-4T1 Four-Channel T1 Multiplexer

Optimux-4T1 Four-Channel T1 Multiplexer Data Sheet Optimux-4T1 Any Traffic Over Fiber Multiplexes four T1 channels over a fiber optics link with various fiber interfaces: multimode, single-mode (up to 120 km), and single-mode over single fiber

More information

Multi-Point Gas Detection and Control System

Multi-Point Gas Detection and Control System Multi-Point Gas Detection and Control System Specifications subject to change without notice. USA 50729 Page of 9 DESCRIPTION Wall mounted, microprocessor-based, multi-point, analog electronic control

More information

Dolphin DXE410 Expansion Chassis

Dolphin DXE410 Expansion Chassis Dolphin DXE410 Expansion Chassis User Guide Revision Information: Revision 2.0 Dolphin Interconnect Solutions, 225 Cedar Hill Street, Marlborough, MA 01752 www.dolphinics.com September 2008 Dolphin Interconnect

More information

Optimux-1553 STM-1/OC-3 Terminal Multiplexer

Optimux-1553 STM-1/OC-3 Terminal Multiplexer Data Sheet Optimux-1553 STM-1/OC-3 terminal multiplexer for grooming high order legacy traffic (TDM) over SDH/SONET networks Any Traffic Over Fiber Multiplexes up to three E3 or T3 data channels using

More information

Optimux-1553 E3/T3 STM-1/OC-3 Terminal Multiplexer

Optimux-1553 E3/T3 STM-1/OC-3 Terminal Multiplexer Data Sheet Optimux-1553 STM-1/OC-3 terminal multiplexer for grooming high-order legacy traffic (TDM) over SDH/SONET networks Up to three E3 or T3 data channels multiplexed using a single hot-swappable

More information

Industrial PC for real-time rapid prototyping KEY FEATURES

Industrial PC for real-time rapid prototyping KEY FEATURES xpc TargetBox Industrial PC for real-time rapid prototyping xpc TargetBox is an industrial PC system that features a combination of performance, ruggedness, and I/O expandability in a compact package specifically

More information

STATE OF NEW JERSEY DEPARTMENT OF TRANSPORTATION TRENTON, NEW JERSEY 08625

STATE OF NEW JERSEY DEPARTMENT OF TRANSPORTATION TRENTON, NEW JERSEY 08625 STATE OF NEW JERSEY DEPARTMENT OF TRANSPORTATION TRENTON, NEW JERSEY 08625 METRIC SPECIFICATIONS FOR VME BUS COMPUTER (FIELD TERMINAL VME BUS PROCESSOR ASSEMBLY) N.J. Specification No. Effective Date:

More information

Optimux-1032, Optimux-1025

Optimux-1032, Optimux-1025 Where to buy > Product page > Data Sheet Optimux-1032, Optimux-1025 Fiber Optic Multiplexer for 16 E1/T1 and Gigabit Ethernet Multiplexes up to 16 E1/T1 with up to 3x10/100/1000 user Ethernet traffic over

More information

Dell SC7020 Storage Controller Getting Started Guide

Dell SC7020 Storage Controller Getting Started Guide Dell SC7020 Storage Controller Getting Started Guide Regulatory Model: E03T Regulatory Type: E03T001 Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make better

More information

3500/22M Transient Data Interface Module

3500/22M Transient Data Interface Module 3500/22M Transient Data Interface Module Product Datasheet Bently Nevada* Asset Condition Monitoring Description The 3500/22M Transient Data Interface (TDI) is the interface between the 3500 monitoring

More information

Dell SCv3000 and SCv3020 Storage System Getting Started Guide

Dell SCv3000 and SCv3020 Storage System Getting Started Guide Dell SCv3000 and SCv3020 Storage System Getting Started Guide Regulatory Model: E03T Regulatory Type: E03T001 Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make

More information

8-Port Industrial USB to RS-232/422/485 Serial Adapter - 15 kv ESD Protection

8-Port Industrial USB to RS-232/422/485 Serial Adapter - 15 kv ESD Protection 8-Port Industrial USB to RS-232/422/485 Serial Adapter - 15 kv ESD Protection Product ID: ICUSB234858I Add extra COM ports to your laptop or desktop computer, quickly and easily. This USB to RS232/422/485

More information

RT4B-110V/12A RECTIFIER

RT4B-110V/12A RECTIFIER The RT4B-110V/12A is a switched mode rectifier (SMR) module designed to provide up to 12A of output current into a 110V nominal system. It can be used with or without a cooling fan. With a fan it runs

More information

MicroNet TMR Control System

MicroNet TMR Control System Product Specification 03363 (Rev. C) MicroNet TMR Control System Applications The MicroNet TMR (triple modular redundant) controller is a state-of-the-art digital control platform designed to reliably

More information

Internet Office 120V 750VA 450W Standby UPS, Ultra-Compact Desktop, USB

Internet Office 120V 750VA 450W Standby UPS, Ultra-Compact Desktop, USB Internet Office 120V 750VA 450W Standby UPS, Ultra-Compact Desktop, USB MODEL NUMBER: INTERNET750U Highlights 750VA ultra-compact 120V standby UPS Maintains AC output during power failures 6 UPS battery

More information

Published by and copyright 2015 Siemens AG Energy Management Freyeslebenstr Erlangen, Germany

Published by and copyright 2015 Siemens AG Energy Management Freyeslebenstr Erlangen, Germany Published by and copyright 2015 Siemens AG Energy Management Freyeslebenstr. 1 91058 Erlangen, Germany For more information, please contact our Customer Support Center Phone: +49 180/524 84 37 Fax: +49

More information

Instruction manual MTL process alarm equipment. October 2016 INM 9000TS Rev 21. System 9000TS. Event recorder

Instruction manual MTL process alarm equipment. October 2016 INM 9000TS Rev 21. System 9000TS. Event recorder Instruction manual MTL process alarm equipment October 06 INM 9000TS Rev System 9000TS Event recorder DECLARATION OF CONFORMITY A printed version of the Declaration of Conformity has been provided separately

More information

expertise beyond controls Vanguard Series 5

expertise beyond controls Vanguard Series 5 expertise beyond controls Vanguard Series 5 The Best of Both Worlds. Series 5 Vanguard controllers provide a flexible combination of CCC and third-party components: Turbomachinery-specific mix of high-speed

More information

LRS-12. "Last Mile" SNMP Modem Rack FEATURES

LRS-12. Last Mile SNMP Modem Rack FEATURES "Last Mile" SNMP Modem Rack FEATURES Accommodates any combination of 12 HDSL, copper or fiber optic modem cards SNMP management agent Supports modems with or without integrated SNMP agent Management running

More information

Allen-Bradley Real Time Clock Module (Cat. No DC)

Allen-Bradley Real Time Clock Module (Cat. No DC) Allen-Bradley (Cat. No. 1771-DC) Product Data Description The (cat. no. 1771-DC) allows you or the PC processor to read or set real time and date information. Real time and date information is block transferred

More information

Modular Power System 1200 W per mainframe GPIB

Modular Power System 1200 W per mainframe GPIB View at www.testequipmentdepot.com High Performance DC Power Supplies 1200 W per mainframe GPIB Modular system permits up to 8 outputs of 150 W per output in 4 U of rack space Reconfigure fast with easily

More information

RT12-240V/2.4kW Rectifier Specification

RT12-240V/2.4kW Rectifier Specification The RT12-240V/2.4kW is a switched mode rectifier (SMR) module that delivers up to 2.4kW of output power (and up to 11A output current) into a 240V nominal DC system. The RT12 suits AC supply voltages between

More information

SEL-2030 Communications Processor

SEL-2030 Communications Processor SEL-2030 Communications Processor Integrate New and Existing Substations Create integrated systems that use substation hardened equipment to collect data from station IEDs, process and concentrate collected

More information

ICS Regent. Multiplexed I/O Modules PD-6035 (T3491)

ICS Regent. Multiplexed I/O Modules PD-6035 (T3491) ICS Regent Multiplexed I/O Modules (T3491) Issue 1, March, 06 Multiplexed I/O modules provide two RS-422 serial port interfaces between the Regent system and ICS s remote multiplexed I/O Unit (MIU) equipment,

More information

Internet Office 120V 550VA 300W Standby UPS, Ultra-Compact Desktop, USB

Internet Office 120V 550VA 300W Standby UPS, Ultra-Compact Desktop, USB Internet Office 120V 550VA 300W Standby UPS, Ultra-Compact Desktop, USB MODEL NUMBER: INTERNET550U Highlights 550VA ultra-compact 120V standby UPS Maintains AC output during power failures 4 UPS battery

More information

BITRONICS 878 DIOD Product Description BITRONICS 878 DIOD DISTRIBUTED INPUT/OUTPUT DEVICE

BITRONICS 878 DIOD Product Description BITRONICS 878 DIOD DISTRIBUTED INPUT/OUTPUT DEVICE BITRONICS 878 DIOD Product Description BITRONICS 878 DIOD DISTRIBUTED INPUT/OUTPUT DEVICE This page intentionally left blank 2 l BITRONICS 878 DIOD APPLICATION NOTE 878 Distributed Input/Output Device

More information

Multi-Point Gas Detection and Control System

Multi-Point Gas Detection and Control System Multi-Point Gas Detection and Control System DESCRIPTION Wall mounted, microprocessor-based, multi-point, analog electronic control system for various gas, temperature and humidity detection, control and

More information

Real-Time Automation Controller (RTAC) Powerful, reliable, and secure multifunction controller

Real-Time Automation Controller (RTAC) Powerful, reliable, and secure multifunction controller SEL-3530 Real-Time Automation Controller (RTAC) Powerful, reliable, and secure multifunction controller Versatile RTAC operates as a supervisory control and data acquisition (SCADA) remote terminal unit

More information

ASMi-52 2/4-wire SHDSL Modem/Multiplexer

ASMi-52 2/4-wire SHDSL Modem/Multiplexer Where to buy > See the product page > Data Sheet ASMi-52 Plastic Enclosure Metal Enclosure Rail-mount Metal Enclosure Dedicated managed SHDSL modem for Ethernet, E1 and serial services over 2- or 4-wire

More information

Modular Master Clock!

Modular Master Clock! Brandywine s Modular Master Clock System represents the next generation of modular timing systems. Built on the highly successful High Performance Timing System, the Modular Master Clock System is a leap

More information

F8008. Fiber Modem for up to 4E1 /8E1 +RS232+Ethernet. + optional V.35/QFXS/QFXO

F8008. Fiber Modem for up to 4E1 /8E1 +RS232+Ethernet. + optional V.35/QFXS/QFXO F8008 Fiber Modem for up to 4E1 /8E1 +RS232+Ethernet + optional V.35/QFXS/QFXO Description F8008 is a fiber optical multiplexer of new generation different from the traditional PDH, multiplexing 1 full

More information

PT-7728/7828 Quick Installation Guide

PT-7728/7828 Quick Installation Guide PT-7728/7828 Quick Installation Guide Moxa PowerTrans Switch Edition 9.0, April 2017 Technical Support Contact Information www.moxa.com/support Moxa Americas: Toll-free: 1-888-669-2872 Tel: 1-714-528-6777

More information

Measurement Systems Datascan Installation and User Guide

Measurement Systems Datascan Installation and User Guide Measurement Systems Datascan Installation and User Guide Supplied By Contents Contents 1. INTRODUCTION... 1 1.1 GENERAL... 1 1.2 DATASCAN MODULE RANGE... 1 1.2.1 Measurement Processors... 1 1.2.2 Analog

More information

DeltaV SX Controller. Introduction. Benefits. Scalable controllers. Quick assembly. Easy to use. Field proven architecture

DeltaV SX Controller. Introduction. Benefits. Scalable controllers. Quick assembly. Easy to use. Field proven architecture DeltaV Distributed Control System Product Data Sheet January 2018 DeltaV SX Controller Scalable controllers Quick assembly Easy to use Field proven architecture Designed for Electronic Marshalling Advanced

More information

TFS 2100 Traveling Wave Fault Location System

TFS 2100 Traveling Wave Fault Location System Traveling Wave Fault Location System The most accurate overhead transmission and distribution line fault locator Accuracy: ±150m typical regardless the line length Unaffected by fault resistance Suitable

More information

IES User Manual. 6 GE + 2 SFP Unmanaged Switch -20 to 60C, DIN-rail. v

IES User Manual. 6 GE + 2 SFP Unmanaged Switch -20 to 60C, DIN-rail. v IES-0823 6 GE + 2 SFP Unmanaged Switch -20 to 60C, DIN-rail User Manual v1.00-1206 Preface A member of the growing family of rugged switches, this switch addresses a need for a smaller switch. This switch

More information

CTO Server and Network Cabinets

CTO Server and Network Cabinets DeltaV Distributed Control System Product Data Sheet January 2018 CTO Server and Network Cabinets CTO Server and Network Cabinet. Delivers standard cabinet with 19 frame construction for your DeltaV networking

More information

Internet Office 120V 350VA 180W Standby UPS, Ultra-Compact Desktop, USB

Internet Office 120V 350VA 180W Standby UPS, Ultra-Compact Desktop, USB Internet Office 120V 350VA 180W Standby UPS, Ultra-Compact Desktop, USB MODEL NUMBER: INTERNET350U Highlights 350VA ultra-compact 120V standby UPS Maintains AC output during power failures 3 UPS battery

More information

F271XA Fiber-Optic Telephone Modem Technical Manual

F271XA Fiber-Optic Telephone Modem Technical Manual F271XA Fiber-Optic Telephone Modem Technical Manual Revision B August 2011 VERSITRON, Inc. 83 Albe Drive / Suite C Newark, DE 19702 www.versitron.com Safeguarding Communications Since 1958 PROPRIETARY

More information

Optimux-108, Optimux-106 Four-Channel E1/T1 and Ethernet Multiplexers

Optimux-108, Optimux-106 Four-Channel E1/T1 and Ethernet Multiplexers Data Sheet Optimux-108, Optimux-106 Fiber Multiplexers, Transmit Any Traffic over Fiber Four E1 or T1 channels and Fast Ethernet link multiplexed over a fiber optic link Various fiber interfaces: multimode,

More information

Unitary Controller. Features. Description. Technical Specification Sheet Rev. 6, March, 2000

Unitary Controller. Features. Description. Technical Specification Sheet Rev. 6, March, 2000 Technical Specification Sheet Rev. 6, March, 2000 Unitary Controller The Unitary Controller can operate as an independent stand-alone controller, or can be connected to the APOGEE Automation System via

More information

F280XD Fiber-Optic RS-232 Modem Technical Manual

F280XD Fiber-Optic RS-232 Modem Technical Manual F280XD Fiber-Optic RS-232 Modem Technical Manual Revision B August 2012 VERSITRON, Inc. 83 Albe Drive / Suite C Newark, DE 19702 www.versitron.com Safeguarding Communications Since 1958 PROPRIETARY DATA

More information

Higher Availability: Self-diagnostics. Automatically tests unit electronics and batteries. Designed to simplify maintenance and troubleshooting.

Higher Availability: Self-diagnostics. Automatically tests unit electronics and batteries. Designed to simplify maintenance and troubleshooting. UPS operation and display panel can rotate 90 degrees, which provides upright viewing for users. Liebert GXT3 UPS Includes These Outstanding Features: Flexibility: Rack/tower configuration. The versatile

More information

XPress-Pro SW Series Hardened Ethernet Switches Enabling Communication for the Demanding Industrial Environment

XPress-Pro SW Series Hardened Ethernet Switches Enabling Communication for the Demanding Industrial Environment XPress-Pro SW Series Hardened Ethernet Switches Enabling Communication for the Demanding Industrial Environment Part of the DeviceLinx family of networkenablement products, XPress-Pro SW series managed

More information

Uninterruptible Power Systems

Uninterruptible Power Systems Uninterruptible Power s 2 S5K Modular Series On-Line Uninterruptible Power s (UPS) The 5K Modular is scalable from 4 to 20 kva, offering many flexible options by adding a few standard modules. Designed

More information

DeltaV SX Controller. DeltaV SX Controller. Introduction. DeltaV Product Data Sheet. Scalable controllers. Quick Assembly.

DeltaV SX Controller. DeltaV SX Controller. Introduction. DeltaV Product Data Sheet. Scalable controllers. Quick Assembly. August 2010 Page 1 The and the DeltaV I/O subsystem make rapid installation easy Scalable controllers Quick Assembly Easy to use Field Proven architecture Designed for Digital Marshalling Advanced Controls

More information

Agilent 66000A 1200 W DC Modular Power System, GPIB

Agilent 66000A 1200 W DC Modular Power System, GPIB Agilent 66000A 1200 W DC Modular Power System, GPIB Data Sheet Speed and accuracy for test optimization 8-slot mainframe accepts up to 8 DC power modules 1200 W total DC power output, up to 150 W per module

More information

POS Series 120V 50/60Hz 500VA 300W Standby UPS, Tower, USB port, 6 Outlets, TEL/DSL Protection

POS Series 120V 50/60Hz 500VA 300W Standby UPS, Tower, USB port, 6 Outlets, TEL/DSL Protection POS Series 120V 50/60Hz 500VA 300W Standby UPS, Tower, USB port, 6 Outlets, TEL/DSL Protection MODEL NUMBER: POS500 Highlights 500VA low-profile tower 120V standby UPS Maintains AC output during power

More information