USER GUIDE. Snow Integration Manager Version 4.5 Release date Document date
|
|
- Chester York
- 5 years ago
- Views:
Transcription
1 USER GUIDE Product Snow Integration Manager Version 4.5 Release date Document date
2 CONTENT ABOUT THIS DOCUMENT... 3 PREREQUISITES... 3 INSTALLATION... 4 CONFIGURATION... 7 GENERAL... 7 INVENTORY FILE HANDLING... 8 CONNECTOR OPTIONS Connector specific options Symantec Altiris 6/ Connector specific options BMC Atrium Discovery and Dependency Mapping Connector specific options Citrix XenServer Connector specific options Dell KACE Connector specific options FrontRange/HEAT Discovery Connector specific options HP Discovery & Dependency Mapping Inventory Connector specific options HP Server Automation Connector specific options IBM Tivoli Asset Discovery for Distributed Connector specific options Inventory File Forwarder Connector specific options iquate iqsonar Connector specific options LANDesk Connector specific options Microsoft Hyper-V Connector specific options Microsoft SCCM 2007/ Connector specific options Snow Device Manager Connector specific options Snow Inventory Oracle Scanner Connector specific options Snow ServiceNow Connector Connector specific options Snow Xml Connector specific options VMware vsphere LOGGING IMPORT PROVIDER SETTINGS Page 2 of 36
3 ABOUT THIS DOCUMENT This document describes how to install and configure Snow Integration Manager (formerly known as the Snow External Data Provider). PREREQUISITES Very important! Read before beginning the installation. Verify that the server meets the system requirements for this product; see the document System Requirements for all Snow products, which is available for download at For configuration of the Snow Integration Connectors, a user account with read-only access rights to the database or on the server is normally required. If additional access rights are required for a specific connector, these will be described in detail in the section of that particular connector. Configuration of Snow third party inventory connector for IBM TAD4D requires that IBM Data Server Driver Package is installed on the server where the Snow Integration Manager is installed. Download the latest version of Snow Integration Manager from ftp.snowsoftware.com. Page 3 of 36
4 INSTALLATION Make sure that the requirements listed in System Requirements for all Snow products are fulfilled before continuing with the installation. 1. Uninstall any previous versions of Snow Integration Manager (or Snow External Data Provider). 2. Double-click on the file SetupSIM.exe to begin the installation. 3. The Snow Integration Manager Setup Wizard is started. 4. Click Next to continue. Page 4 of 36
5 5. Read and accept the terms of the End User License Agreement. 6. Click Next to continue. 7. Select destination folder and which connectors to install. 8. Click Next to continue. 9. Click Install to start the installation. Page 5 of 36
6 10. The Snow Integration Manager is installed. 11. Click Finish to exit the Setup Wizard. Page 6 of 36
7 CONFIGURATION To configure the Snow Integration Manager, open the Snow Integration Manager Properties which is located in the start menu under Snow Software/ Snow Integration Manager. GENERAL Select global settings for Site id and aggregation scheduling. The global Site id setting can be overridden using the Site id setting in the connector specific options. NOTE: The global setting for aggregation scheduling will affect all connectors. If connectors are to be scheduled separately, do not enable this setting. 1. In the Site id text box, enter the name provided by the Service Provider (SPE platforms only), or the default site name used in the Snow Inventory installation (Enterprise). 2. In the Scheduling section, schedule an aggregation interval (or disable it). Page 7 of 36
8 INVENTORY FILE HANDLING Select method for handling of inventory data. 1. When Snow Inventory Server is running on the same server as the Snow Integration Manager, select the Save to local inventory server option and specify the incoming folder in the Inventory incoming file folder field. Example: C:\Program Files\Snow Software\Snow Inventory\Data\Incoming 2. When sending the inventory data to a remote server, select the Save to remote inventory server option (i.e. Snow Inventory Data Receiver) and enter the complete URL in the Url text box. Example: To enter proxy settings, click Proxy. To activate the proxy functionality, enable the Use proxy option. In the Settings section, use the default proxy configured in Internet Explorer by enabling the Use default proxy option, or configure manual proxy settings in the text boxes below. Page 8 of 36
9 3. In the Software filtering section, folder paths and file types which by default are excluded from/included in the inventory are listed. NOTE: Software filtering is only applicable for the Microsoft SCCM 2007/2012 and LANDesk connectors. Example: By default, all content of the folder _:\WINDOWS\* will be excluded except for the folder _:\WINDOWS\SYSTEM32\SPOOL\DRIVERS\*. By default, only.exe and.dll file types will be included in the inventory, but more file types can be added. To remove a filter, select filter in the list and click Remove. To create a new filter, click Add. 4. To exclude a folder, enter a path in the Filter text box and enable the Excluding option. Click Save. 5. To include a folder in an already excluded path, enter a path in the Filter text box and leave Excluding disabled (cleared). Click Save. 6. To include a new file extension, enter the extension in the Filter text and enable the Is extension option. Click Save. Page 9 of 36
10 CONNECTOR OPTIONS 1. To add connectors, select connector in the Available connectors list and click Add >>. 2. To remove connectors from the Active connectors list, select connector and click << Remove. 3. To configure connector specific options, click Settings; see the sections that follow. 4. To configure a schedule for a selected Active connector, click Schedule. 5. To rename an Active connector, select connector and click Rename. 6. Click Aggregate selected to immediately start aggregation for a selected connector. This option is mostly used for testing purposes. 7. In the Missing metadata reporting level drop-down list, select how to handle reporting of missing metadata. 8. Enable the Include software with missing metadata option to include software that lacks description. Filename will be used as placeholder for the description. Page 10 of 36
11 CONNECTOR SPECIFIC OPTIONS SYMANTEC ALTIRIS 6/7 The Symantec Altiris 6/7 connector uses a database connection. 1. In the Server text box, enter the SQL server name. 2. Enter user credentials for the Symantec Altiris database in the User id and Password text boxes - or Enable the Use integrated security option. 3. In the Database drop-down list, select database. 4. To verify the connection, click Test connection. 5. In the Initial aggregation length field, select number of months for initial aggregation of inventory data. 6. To reset an ongoing incremental aggregation, click Clear Last Aggregation Date. 7. Optionally, enter a Site Id for this connector. Page 11 of 36
12 CONNECTOR SPECIFIC OPTIONS BMC ATRIUM DISCOVERY AND DEPENDENCY MAPPING The BMC ADDM connector uses an API connection. DATA CONNECTION 1. In the Server text box, enter the server URL. Example: 2. Enter user credentials for the server connection in the User id and Password text boxes. 3. To verify the connection, click Test connection. 4. In the Initial aggregation length field, select number of months for initial aggregation of inventory data. 5. To reset an ongoing incremental aggregation, click Clear Last Aggregation Date. 6. Optionally, enter a Site id for this connector HOST FILTERING 1. To include or exclude computers, define a filter based on a computer attribute. Multiple criteria can be used in the filter. 2. To add the created filter, click Add. 3. To test the filter and check the result, click Preview. 4. To remove a created filter, click Remove. Page 12 of 36
13 CONNECTOR SPECIFIC OPTIONS CITRIX XENSERVER The Citrix XenServer connector uses an API connection. 1. In the Site name text box, enter a site name for this collection of XenServer servers. 2. To add one or more XenServer servers to scan for virtual machines, click Add. 3. In the Name text box, enter a name for the server. 4. Enable the Use this name as datacenter name option to use the entered name instead of the default name of the server. 5. Select whether HyperThreading is enabled on the hosts to ensure that correct processor core count is reported to Snow License Manager. 6. Enter IP address, Port, and user credentials to access the server. XenServer uses port 80 by default, so use that port on a default installation. 7. To verify the connection, click Test. 8. Click OK to save settings and close the Citrix XenServer dialog. 9. Click OK to save the settings. Page 13 of 36
14 XENSERVER TOOLS The connector will be able to extract more information from virtual machines with XenServer Tools installed. Install XenServer Tools on all VMs to retrieve the maximum amount of information. HOSTS AND VIRTUAL MACHINES If a VM is not running, it is not necessarily associated with any host. It is only when a VM is running that a host is defined. This means that a VM that is not running may in fact be associated with *no* host. When the connector is trying to figure out which host a VM is associated with, the following logic is used: 1. If the VM is running, the host is known and we use that. 2. If the VM is not running, the host is inferred by the VM's affinity field (the preferred starting host). 3. If the host could not be inferred, the VM is ignored. XENSERVER CONNECTOR AND SSL 1. Configure the connector to communicate over HTTPS by specifying port 443 in the server settings. Page 14 of 36
15 A default XenServer installation uses a self-signed certificate for TLS/SSL. To make the connector work over HTTPS, either replace the default certificate with one from a trusted certificate authority, or add XenServer s self-signed certificate to the client machine s trusted certificate store. To replace XenServer s default certificate, refer to the XenServer documentation. To trust the self-signed certificate, follow the steps described below on the machine that the connector is running on. 1. Start Internet Explorer using the running as administrator option. 2. Navigate to the XenServer over HTTPS. 3. If this warning is displayed, XenServer is not using a trusted certificate. 4. Click Continue to this website. 5. Click the Security report icon in the URL and click View certificates. Page 15 of 36
16 6. In the Certificate dialog, click Install Certificate The Certificate Import Wizard is started. 8. Select Local Machine and click Next. Page 16 of 36
17 9. Select Place all certificates in the following store. 10. Click Browse and select Trusted Root Certification Authorities. Click OK. 11. Click Next. 12. Click Finish to start the import. 13. A message box should be displayed informing that the import was successful. 14. Restart Internet Explorer and verify that it is possible to navigate to the XenServer over HTTPS without getting a certificate warning. Page 17 of 36
18 CONNECTOR SPECIFIC OPTIONS DELL KACE 1000 The Dell KACE 1000 connector uses a database connection. 1. In the Server text box, enter the MySQL server name. 2. Enter user credentials for the Dell KACE 1000 database in the User id and Password text boxes - or - Enable the Use integrated security option. 3. In the Database text box, enter the name of the database. 4. To verify the connection, click Test connection. 5. In the Initial aggregation length field, select number of months for initial aggregation of inventory data. 6. To reset an ongoing incremental aggregation, click Clear Last Aggregation Date. 7. Optionally, enter a Site id for this connector. Page 18 of 36
19 CONNECTOR SPECIFIC OPTIONS FRONTRANGE/HEAT DISCOVERY The FrontRange/HEAT Discovery connector uses a database connection. 1. In the Server text box, enter the SQL server name. 2. Enter user credentials for the FrontRange/HEAT Discovery database in the User id and Password text boxes - or Enable the Use integrated security option. 3. In the Database drop-down list, select database. 4. To verify the connection, click Test connection. 5. In the text box Organizations that start with, specify an organization filter which will be used to select computers that are connected to those organizations. Use % as a wildcard. 6. In the Initial aggregation length field, select number of months for initial aggregation of inventory data. 7. To reset an ongoing incremental aggregation, click Clear Last Aggregation Date. 8. Optionally, enter a Site id for this connector. Page 19 of 36
20 CONNECTOR SPECIFIC OPTIONS HP DISCOVERY & DEPENDENCY MAPPING INVENTORY The HP DDMI connector reads data from files in a folder. The HP Discovery & Dependency Mapping Inventory (HP DDMI) connector opens each of the HP DDMI scan files (.xsf) and converts the inventory data to a standard Snow inventory file that can be integrated with the Snow database. 1. In the XSF scan file folder text box, enter the folder where the HP DDMI connector will look for HP DDMI XSF scan files. 2. Optionally, enter a Site id for this connector. 3. In the Initial aggregation length field, select number of months for initial aggregation of inventory data. 4. To reset an ongoing incremental aggregation, click Clear Last Aggregation Date. NOTE: Due to high CPU and memory usage the recommendation is to use a server with higher performance than the recommended minimum SIM server requirements, or there is a risk that the HP DDMI aggregation will underperform. Page 20 of 36
21 CONNECTOR SPECIFIC OPTIONS HP SERVER AUTOMATION The HP Server Automation connector uses an API connection. 1. In the Server text box, enter the server URL. Example: 2. Enter user credentials for the server connection in the User id and Password text boxes. 3. To verify the connection, click Test connection. 4. In the Initial aggregation length field, select number of months for initial aggregation of inventory data. 5. To reset an ongoing incremental aggregation, click Clear Last Aggregation Date. 6. Optionally, enter a Site id for this connector KNOWN LIMITATIONS When gathering inventory data from HP Server Automation (HPSA) using this integration connector the actual servers running the HPSA software itself will not be included and presented in Snow License Manager. This is due to a limitation in the HPSA API that excludes these servers from the list of devices managed by HPSA. Page 21 of 36
22 CONNECTOR SPECIFIC OPTIONS IBM TIVOLI ASSET DISCOVERY FOR DISTRIBUTED The IBM TAD4D connector uses a database connection. 1. In the Server text box, enter the DB2 server name. 2. Enter user credentials for the IBM TAD4D database in the User id and Password text boxes. 3. In the Database text box, enter the name of the database. 4. In the Port text box, enter the database server port. 5. To verify the connection, click Test connection. 6. In the Period (days) field, enter the number of days to be included in the period for Sub Capacity Reporting. 7. In the Initial aggregation length field, select number of months for initial aggregation of inventory data. 8. To reset an ongoing incremental aggregation, click Clear Last Aggregation Date. 9. Optionally, enter a Site id for this connector. Page 22 of 36
23 CONNECTOR SPECIFIC OPTIONS INVENTORY FILE FORWARDER The Inventory File Forwarder connector reads data from files in a folder. 1. In the Inventory file folder text box, enter the folder where the connector will look for inventory files. 2. In the Data receiver url text box, enter the complete URL to the Inventory Data Receiver. Example: 3. To verify the connection, click Test. 4. Optionally, enter a Site id for this connector. 5. Enable the Use proxy option to activate the proxy functionality. 6. In the Settings section, use the default proxy configured in Internet Explorer by enabling the Use default proxy option, or configure manual proxy settings by using the text boxes. Page 23 of 36
24 CONNECTOR SPECIFIC OPTIONS IQUATE IQSONAR The iqsonar connector uses a database connection. 1. In the Server text box, enter the SQL server name. 2. Enter user credentials for the iqsonar database in the User id and Password text boxes - or Enable the Use integrated security option. 3. In the Database drop-down list, select database. 4. To verify the connection, click Test connection. 5. In the Initial aggregation length field, select number of months for initial aggregation of inventory data. 6. To reset an ongoing incremental aggregation, click Clear Last Aggregation Date. 7. Optionally, enter a Site id for this connector. Page 24 of 36
25 CONNECTOR SPECIFIC OPTIONS LANDESK The LANDesk connector uses a database connection. 1. In the Server text box, enter the SQL server name. 2. Enter user credentials for the LANDesk database in the User id and Password text boxes - or Enable the Use integrated security option. 3. In the Database drop-down list, select database. 4. To verify the connection, click Test connection. 5. In the Initial aggregation length field, select number of months for initial aggregation of inventory data. 6. To reset an ongoing incremental aggregation, click Clear Last Aggregation Date. 7. Optionally, enter a Site id for this connector. Page 25 of 36
26 CONNECTOR SPECIFIC OPTIONS MICROSOFT HYPER-V The Microsoft Hyper-V connector uses an API connection. SYSTEM REQUIREMENTS When running SIM from Windows 7 or Windows Server 2008, Windows Management Framework 3.0 must be installed. Logon credentials: o Standalone Hyper-V servers: The credentials must have access to the server s WMI interface. o VMM servers: The user must be an Administrator on the VMM server. The user must also be added to a role with read rights in Virtual Machine Manager Console on the VMM server (in the console, go to Settings User roles). VMM servers: Make sure that PowerShell Remoting is enabled on the server. Example of PowerShell script: o Enable-PSRemoting Force If the connection fails to a server that is not a member of the domain, or if connection by IP address is used, the server s IP address (or name) might need to be added to TrustedHosts on the local computer. Example of PowerShell script: set-item wsman:\localhost\client\trustedhosts -Value xxx.xxx.xxx.xxx, xxx.xxx.xxx.xxx, NOTE: The recommendation is to either install the Snow Inventory Client for Windows on the virtual machines or gather inventory data from the virtual machines using another SIM connector. The Hyper-V connector does not perform software scan on the virtual machines. Page 26 of 36
27 1. In the Site name text box, enter the site name for this collection of Hyper-V servers. This setting will override the Global site id. 2. To add one or more Hyper-V servers to scan for virtual machines, click Add. 3. In the Server name or IP text box, enter the hostname or IP address of the server (. for localhost). 4. Specify whether this is a single Hyper-V server or a VMM server controlling one or more Hyper-V hosts. For a VMM server, select whether HyperThreading is enabled on the hosts to ensure that the correct processor core count is reported to Snow License Manager. 5. Enter logon credentials (username or DOMAIN\username) in the User and Password textboxes. 6. By default, each virtual machine s name is its Fully Qualified Domain Name (computer name + domain; MYCOMPUTER.mydomain.local). If only the computer name is needed, enable the Remove domain suffix option. 7. To verify the connection, click Test. Page 27 of 36
28 CONNECTOR SPECIFIC OPTIONS MICROSOFT SCCM 2007/2012 The Microsoft SCCM 2007/2012 connector uses a database connection. DATA CONNECTION 1. In the Server text box, enter the SQL server name. 2. Enter user credentials for the SCCM database in the User id and Password text boxes - or Enable the Use integrated security option. 3. In the Database drop-down list, select database. 4. To verify the connection, click Test connection. 5. In the Initial aggregation length field, select number of months for initial aggregation of inventory data. 6. To reset an ongoing incremental aggregation, click Clear Last Aggregation Date. 7. Select Identifier. 8. Optionally, enter a Site id for this connector. Page 28 of 36
29 DATA SOURCE OPTIONS The SCCM data source options gives a better overview of the SCCM setup and what views and fields the Snow Integration Manager is able to aggregate from. It is also possible to apply filters to collections and clients. 1. Collection filter (SiteID) In the Collection filter text box, enter the Site ID s that clients will be aggregated from. Use semi colon as separator. 2. Client filter In the Client filter text box, enter the names of the clients that will be aggregated. Use semi colon as separator. A wildcard (* or %) can be used to match several clients. Example: Enter STO-* for all clients with a name beginning with STO-. 3. Enable Apply software exclusion filters to metering data by enabling this option. 4. To test the filters, click Preview. Select the Use config value checkbox to use the last aggregation date. Note that this will either be the last aggregation date if such a value exists, or todays date subtracted with the number of months specified for initial aggregation. Clear the Use config value checkbox to enter a manual date for the preview. Page 29 of 36
30 CONNECTOR SPECIFIC OPTIONS SNOW DEVICE MANAGER The Snow Device Manager connector uses an API connection. 1. In the SDM Web API URL text box, enter the URL to the Snow Device Manager Web API. 2. In the Domain, User Name, and Password text boxes, enter credentials for a domain user account with administrative privileges in the Snow Device Manager platform. 3. To only include information on registered devices, enable the Include only enrolled devices option. 4. To verify the SDM connection, click Test connection. 5. In the Initial aggregation length field, select number of months for initial aggregation of inventory data. 6. To reset an ongoing incremental aggregation, click Clear Last Aggregation Date. Page 30 of 36
31 CONNECTOR SPECIFIC OPTIONS SNOW INVENTORY ORACLE SCANNER The Snow Inventory Oracle Scanner connector reads data from files in a folder. This connector is used for import of Snow Inventory Oracle Scanner 2.x output xml files. It is also used for processing of inventory result xml files generated by the Snow Inventory Client for Unix. 1. Add one or more folders where Snow Inventory Oracle Scanner will look for xml files. 2. Optionally, enter a Site id for this connector. Page 31 of 36
32 CONNECTOR SPECIFIC OPTIONS SNOW SERVICENOW CONNECTOR The Snow ServiceNow connector uses an API connection. 1. In the SLM Web API URL text box, enter the URL to the Snow License Manager Web API. 2. In the User Name and Password text boxes, enter credentials for a user account with administrative privileges in the Snow License Manager platform. To verify the SLM connection, click Test connection. 3. For SPE platforms only In the Customer dropdown list, select the customer for whom information will be replicated. 4. In the ServiceNow URL text box, enter the URL to the ServiceNow instance. 5. In the User Name and Password textboxes, enter user credentials for an administrative account in the ServiceNow platform. 6. To verify the ServiceNow connection, click Test connection. 7. To exclude replication of inventory information on users, disable the option Include Users (the option is enabled by default). 8. To reset an ongoing incremental import and perform a full import instead, click Clear Last Import Date. NOTE: A user account is required to run the ServiceNow web services. The user account needs to be associated with the soap, import_transformer, and itil roles. Page 32 of 36
33 CONNECTOR SPECIFIC OPTIONS SNOW XML The Snow XML connector reads data from files in a folder. Snow XML is an xml format that enables integration of data from any other hardware and/or software inventory system. The Snow XML connector reads data from a structured xml file and converts it to the standard Snow Inventory format. 1. Enter a folder where Snow XML will look for xml files. 2. Optionally, enter a Site id for this connector. Page 33 of 36
34 CONNECTOR SPECIFIC OPTIONS VMWARE VSPHERE The VMware vsphere connector uses an API connection. 1. In the Site name text box, enter a site name for this collection of vsphere servers. This setting will override the Global site id. 2. To add one or more vsphere servers to scan for virtual machines, click Add. 3. In the Name text box, enter a name for the server. 4. Enable the Use this name as default name for data center option to use the entered name instead of vsphere s default ha-datacenter name. 5. Enter the Webservice url and user credentials to access the server s VMware vsphere Web Services SDK. 6. To verify the connection, click Test. NOTE: To have the complete license key for each vsphere host displayed in Snow License Manager, the entered user account needs to be assigned a vcenter Server Role with the granted privilege License of the Global privilege category. Page 34 of 36
35 LOGGING On the Logging tab specifications can be made on what information to append to the log files, how the files are formatted, where they are located, and allowed number and size of the files (default settings are recommended). Page 35 of 36
36 IMPORT PROVIDER SETTINGS From Snow Integration Manager (named EDP when released) version 4.1 it is possible to import the active provider settings from an earlier External Data Provider 3.x installation, if installed on the same computer. All existing settings on the General tab (company name, site name, schedules) for the Snow Integration Manager will remain the same as in the earlier installation. The Snow Integration Manager Properties application presents the user with an option to import the settings the first time it starts. Note that this message will be displayed only once regardless of the answer being Yes or No. Page 36 of 36
USER GUIDE. Snow Integration Manager Version 4.3 Release date Installation Configuration Import provider settings Document date
USER GUIDE Product Snow Integration Manager Version 4.3 Release date 2014-12-18 Content Prerequisites Installation Configuration Import provider settings Document date 2015-01-19 CONTENT ABOUT THIS DOCUMENT...
More informationUSER GUIDE. Snow Integration Manager. Version 4.7. Release date Document date SNOWSOFTWARE.COM
USER GUIDE Product Snow Integration Manager Version 4.7 Release date 2016-05-16 Document date 2016-08-30 CONTENTS Introduction... 4 Prerequisites... 4 Installation... 5 Configuration... 6 General... 6
More informationUSER GUIDE. Snow Integration Manager. Version 5.5. Release date Document date SNOWSOFTWARE.COM
USER GUIDE Product Snow Integration Manager Version 5.5 Release date 2017-09-27 Document date 2017-10-05 CONTENTS 1 Introduction... 4 1.1 Prerequisites... 4 2 Installation... 5 2.1 New installation...
More informationSNOW LICENSE MANAGER (7.X)... 3
SYSTEM REQUIREMENTS Products Snow License Manager Snow Inventory Server, IDR, IDP Client for Windows Client for Linux Client for Unix Client for OS X Oracle Scanner Snow Integration Manager Snow Distribution
More informationSYSTEM REQUIREMENTS SNOW PRODUCTS. Document date
SYSTEM REQUIREMENTS SNOW PRODUCTS Document date 2017-12-13 CONTENTS SNOW LICENSE MANAGER (8.X)... 4 DEPENDENCIES ON OTHER SNOW PRODUCTS... 4 CLIENT REQUIREMENTS... 5 Administration Tool requirements (Windows
More informationSNOW LICENSE MANAGER (7.X)... 3
SYSTEM REQUIREMENTS Products Snow License Manager Snow Inventory Server, IDR, IDP Client for Windows Client for Linux Client for Unix Client for OS X Oracle Scanner External Data Provider Snow Distribution
More informationStorage Manager 2018 R1. Installation Guide
Storage Manager 2018 R1 Installation Guide Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make better use of your product. CAUTION: A CAUTION indicates either
More informationDell Storage Manager 2016 R3 Installation Guide
Dell Storage Manager 2016 R3 Installation Guide Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make better use of your product. CAUTION: A CAUTION indicates either
More informationMicrosoft Windows Apple Mac OS X
Products Snow License Manager Snow Inventory Server, IDR, IDP Client for Windows Client for Linux Client for Unix Client for OS X Oracle Scanner External Data Provider Snow Distribution Date 2014-09-09
More informationInstalling and Configuring vcloud Connector
Installing and Configuring vcloud Connector vcloud Connector 2.6.0 This document supports the version of each product listed and supports all subsequent versions until the document is replaced by a new
More informationDell SupportAssist Version For Dell OpenManage Essentials Quick Start Guide
Dell SupportAssist Version 1.2.1 For Dell OpenManage Essentials Quick Start Guide Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make better use of your computer.
More informationConfiguring ApplicationHA in VMware SRM 5.1 environment
Configuring ApplicationHA in VMware SRM 5.1 environment Windows Server 2003 and 2003 R2, Windows Server 2008 and 2008 R2 6.0 September 2013 Contents Chapter 1 About the ApplicationHA support for VMware
More informationInstalling and Configuring vcloud Connector
Installing and Configuring vcloud Connector vcloud Connector 2.5.0 This document supports the version of each product listed and supports all subsequent versions until the document is replaced by a new
More informationDell Server Management Pack Suite Version For Microsoft System Center Operations Manager And System Center Essentials Installation Guide
Dell Server Management Pack Suite Version 5.0.1 For Microsoft System Center Operations Manager And System Center Essentials Installation Guide Notes, Cautions, and Warnings NOTE: A NOTE indicates important
More informationUsing vrealize Operations Tenant App as a Service Provider
Using vrealize Operations Tenant App as a Service Provider Using vrealize Operations Tenant App as a Service Provider You can find the most up-to-date technical documentation on the VMware Web site at:
More informationDell SupportAssist Version 1.2 For Dell OpenManage Essentials Quick Start Guide
Dell SupportAssist Version 1.2 For Dell OpenManage Essentials Quick Start Guide Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make better use of your computer.
More informationGoliath Performance Monitor v11.7 POC Install Guide
Goliath Performance Monitor v11.7 POC Install Guide Goliath Performance Monitor Proof of Concept Limitations Goliath Performance Monitor Proof of Concepts (POC) will be limited to monitoring 5 Hypervisor
More informationInstalling and Configuring vcenter Multi-Hypervisor Manager
Installing and Configuring vcenter Multi-Hypervisor Manager vcenter Server 5.1 vcenter Multi-Hypervisor Manager 1.1.2 This document supports the version of each product listed and supports all subsequent
More informationGoliath Performance Monitor v11.7 Installation Guide
Goliath Performance Monitor v11.7 Installation Guide http://www.goliathtechnologies.com 1 Legal Notices Inc. All rights reserved. www.goliathtechnologies.com Goliath Technologies believes the information
More informationInstallation Guide. Mobile Print for Business version 1.0. July 2014 Issue 1.0
Installation Guide Mobile Print for Business version 1.0 July 2014 Issue 1.0 Fuji Xerox Australia 101 Waterloo Road North Ryde NSW 2113 For technical queries please contact the Fuji Xerox Australia Customer
More informationClick Studios. Passwordstate. Password Discovery, Reset and Validation. Requirements
Passwordstate Password Discovery, Reset and Validation Requirements This document and the information controlled therein is the property of Click Studios. It must not be reproduced in whole/part, or otherwise
More informationReconfiguring VMware vsphere Update Manager. Update 1 VMware vsphere 6.5 vsphere Update Manager 6.5
Reconfiguring VMware vsphere Update Manager Update 1 VMware vsphere 6.5 vsphere Update Manager 6.5 You can find the most up-to-date technical documentation on the VMware website at: https://docs.vmware.com/
More informationInSync Service User Guide
InSync Service User Guide Matrix Logic Corporation 1 Published by Matrix Logic Corporation Copyright 2011 by Matrix Logic Corporation All rights reserved. No part of the content of this manual may be reproduced
More informationDell EMC Ready Architectures for VDI
Dell EMC Ready Architectures for VDI Designs for Citrix XenDesktop and XenApp for Dell EMC XC Family September 2018 H17388 Deployment Guide Abstract This deployment guide provides instructions for deploying
More informationPolicy Manager for IBM WebSphere DataPower 7.2: Configuration Guide
Policy Manager for IBM WebSphere DataPower 7.2: Configuration Guide Policy Manager for IBM WebSphere DataPower Configuration Guide SOAPMDP_Config_7.2.0 Copyright Copyright 2015 SOA Software, Inc. All rights
More informationDell EMC Ready System for VDI on VxRail
Dell EMC Ready System for VDI on VxRail Citrix XenDesktop for Dell EMC VxRail Hyperconverged Appliance April 2018 H16968.1 Deployment Guide Abstract This deployment guide provides instructions for deploying
More informationIBM. Migration Cookbook. Migrating from License Metric Tool and Tivoli Asset Discovery for Distributed 7.5 to License Metric Tool 9.
IBM License Metric Tool 9.x Migration Cookbook Migrating from License Metric Tool and Tivoli Asset Discovery for Distributed 7.5 to License Metric Tool 9.x IBM IBM License Metric Tool 9.x Migration Cookbook
More informationTECHNICAL DESCRIPTION
TECHNICAL DESCRIPTION Product Snow Inventory Version 5 Release date 2016-09-27 Document date 2017-11-24 CONTENTS 1 Introduction... 3 1.1 What s new?... 3 2 Platform overview... 4 2.1 Architecture... 4
More informationForeScout Open Integration Module: Data Exchange Plugin
ForeScout Open Integration Module: Data Exchange Plugin Version 3.2.0 Table of Contents About the Data Exchange Plugin... 4 Requirements... 4 CounterACT Software Requirements... 4 Connectivity Requirements...
More informationReconfiguring VMware vsphere Update Manager. 17 APR 2018 VMware vsphere 6.7 vsphere Update Manager 6.7
Reconfiguring VMware vsphere Update Manager 17 APR 2018 VMware vsphere 6.7 vsphere Update Manager 6.7 You can find the most up-to-date technical documentation on the VMware website at: https://docs.vmware.com/
More informationREVISED 1 AUGUST REVIEWER'S GUIDE FOR VMWARE APP VOLUMES VMware App Volumes and later
REVISED 1 AUGUST 2018 REVIEWER'S GUIDE FOR VMWARE APP VOLUMES VMware App Volumes 2.13.1 and later Table of Contents Introduction Audience What You Will Learn Navigating This Document for App Volumes Use
More informationREVISED 1 AUGUST QUICK-START TUTORIAL FOR VMWARE APP VOLUMES VMware App Volumes and later
REVISED 1 AUGUST 2018 QUICK-START TUTORIAL FOR VMWARE APP VOLUMES VMware App Volumes 2.13.1 and later Table of Contents Introduction Audience What You Will Learn Navigating This Document for App Volumes
More informationForeScout Extended Module for Qualys VM
ForeScout Extended Module for Qualys VM Version 1.2.1 Table of Contents About the Qualys VM Integration... 3 Additional Qualys VM Documentation... 3 About This Module... 3 Components... 4 Considerations...
More informationGetting Started with ESXi Embedded
ESXi 4.0 Embedded vcenter Server 4.0 This document supports the version of each product listed and supports all subsequent versions until the document is replaced by a new edition. To check for more recent
More informationForeScout CounterACT. Configuration Guide. Version 3.4
ForeScout CounterACT Open Integration Module: Data Exchange Version 3.4 Table of Contents About the Data Exchange Module... 4 About Support for Dual Stack Environments... 4 Requirements... 4 CounterACT
More informationOpenManage Integration for VMware vcenter Using the vsphere Client Quick Install Guide Version 2.0
OpenManage Integration for VMware vcenter Using the vsphere Client Quick Install Guide Version 2.0 Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make better
More informationNBC-IG Installation Guide. Version 7.2
Installation Guide Version 7.2 2017 Nuance Business Connect 7.2 Installation Guide Document Revision History Revision Date August 8, 2017 Revision List Updated supported SQL Server versions June 14, 2017
More informationCounterACT VMware vsphere Plugin
CounterACT VMware vsphere Plugin Configuration Guide Version 2.0.0 Table of Contents About VMware vsphere Integration... 4 Use Cases... 4 Additional VMware Documentation... 4 About this Plugin... 5 What
More informationMigration from version 7.5 to 9.0. IBM License Metric Tool & Software Use Analysis Questions and Answers ILMT Central Team
Migration from version 7.5 to 9.0 IBM License Metric Tool & Software Use Analysis Questions and Answers ILMT Central Team Agenda Introduction 01 Step 1: Prepare the environment 02 Step 2: Map the agents
More informationClient Installation and User's Guide
IBM Tivoli Storage Manager FastBack for Workstations Version 7.1.1 Client Installation and User's Guide SC27-2809-04 IBM Tivoli Storage Manager FastBack for Workstations Version 7.1.1 Client Installation
More informationDeploying VMware Identity Manager in the DMZ. SEPT 2018 VMware Identity Manager 3.3
Deploying VMware Identity Manager in the DMZ SEPT 2018 VMware Identity Manager 3.3 You can find the most up-to-date technical documentation on the VMware website at: https://docs.vmware.com/ If you have
More informationDeploying VMware Identity Manager in the DMZ. JULY 2018 VMware Identity Manager 3.2
Deploying VMware Identity Manager in the DMZ JULY 2018 VMware Identity Manager 3.2 You can find the most up-to-date technical documentation on the VMware website at: https://docs.vmware.com/ If you have
More informationUSER GUIDE. Snow Inventory Server. Version 5.2. Release date Document date SNOWSOFTWARE.COM
USER GUIDE Product Snow Inventory Server Version 5.2 Release date 2017-09-20 Document date 2017-12-07 CONTENTS 1 Introduction... 3 1.1 New installation vs Upgrade... 3 1.2 Prerequisites... 3 1.3 Definitions...
More informationInviso SA. Step-by-Step Guide DATE: NOVEMBER 21, 2017
Inviso SA Step-by-Step Guide DATE: NOVEMBER 21, 2017 1 Section 1: Introduction Inviso Software Analyzer The Inviso Software Analyzer (InvisoSA.com) is an IT inventory processing service that transforms
More informationClient Installation and User's Guide
IBM Tivoli Storage Manager FastBack for Workstations Version 7.1 Client Installation and User's Guide SC27-2809-03 IBM Tivoli Storage Manager FastBack for Workstations Version 7.1 Client Installation
More informationKYOCERA Net Admin User Guide
KYOCERA Net Admin User Guide Legal Notes Unauthorized reproduction of all or part of this guide is prohibited. The information in this guide is subject to change without notice. We cannot be held liable
More informationData Protection Guide
SnapCenter Software 4.1 Data Protection Guide For VMs and Datastores using the SnapCenter Plug-in for VMware vsphere September 2018 215-13399_B0 doccomments@netapp.com Table of Contents 3 Contents Deciding
More informationEntrust Connector (econnector) Venafi Trust Protection Platform
Entrust Connector (econnector) For Venafi Trust Protection Platform Installation and Configuration Guide Version 1.0.5 DATE: 17 November 2017 VERSION: 1.0.5 Copyright 2017. All rights reserved Table of
More informationVersion 2.3 User Guide
V Mware vcloud Usage Meter Version 2.3 User Guide 2012 VMware, Inc. All rights reserved. This product is protected by U.S. and international copyright and intellectual property laws. This product is covered
More informationFlexNet Manager Suite 2015 R2 SP5 FlexNet Manager Suite 2015 Release 2 Service Pack 5
FlexNet Manager Suite 2015 R2 SP5 FlexNet Manager Suite 2015 Release 2 Service Pack 5 Release Notes Updated May 31, 2016 The current edition of these Release Notes is published here. FlexNet Manager Suite
More informationSnapCenter Software 4.0 Installation and Setup Guide
SnapCenter Software 4.0 Installation and Setup Guide March 2018 215-12926_C0 doccomments@netapp.com Table of Contents 3 Contents Deciding whether to read the SnapCenter Installation and Setup Guide...
More informationDell EMC Ready System for VDI on XC Series
Dell EMC Ready System for VDI on XC Series Citrix XenDesktop for Dell EMC XC Series Hyperconverged Appliance March 2018 H16969 Deployment Guide Abstract This deployment guide provides instructions for
More informationConnection Broker Managing User Connections to Workstations and Blades, OpenStack Clouds, VDI, and More
Connection Broker Managing User Connections to Workstations and Blades, OpenStack Clouds, VDI, and More Quick Start Using Leostream with Citrix XenDesktop 7 and HDX Version 8.1 January 14, 2016 Contacting
More informationClick Studios. Passwordstate. Password Discovery, Reset and Validation. Requirements
Passwordstate Password Discovery, Reset and Validation Requirements This document and the information controlled therein is the property of Click Studios. It must not be reproduced in whole/part, or otherwise
More informationData Protection Guide
SnapCenter Software 4.0 Data Protection Guide For VMs and Datastores using the SnapCenter Plug-in for VMware vsphere March 2018 215-12931_C0 doccomments@netapp.com Table of Contents 3 Contents Deciding
More informationVMware vcenter Site Recovery Manager 4.1 Evaluator s Guide EVALUATOR'S GUIDE
VMware vcenter Site Recovery Manager 4.1 EVALUATOR'S GUIDE Table of Contents. Getting Started.... 3 About VMware vcenter Site Recovery Manager.... 3 About This Guide.... 3 Intended Audience.... 3 Assumptions....
More informationDeveloping and Deploying vsphere Solutions, vservices, and ESX Agents
Developing and Deploying vsphere Solutions, vservices, and ESX Agents vsphere 6.0 This document supports the version of each product listed and supports all subsequent versions until the document is replaced
More informationDeveloping and Deploying vsphere Solutions, vservices, and ESX Agents. 17 APR 2018 vsphere Web Services SDK 6.7 vcenter Server 6.7 VMware ESXi 6.
Developing and Deploying vsphere Solutions, vservices, and ESX Agents 17 APR 2018 vsphere Web Services SDK 6.7 vcenter Server 6.7 VMware ESXi 6.7 You can find the most up-to-date technical documentation
More informationKYOCERA Net Admin Installation Guide
KYOCERA Net Admin Guide Legal Notes Unauthorized reproduction of all or part of this guide is prohibited. The information in this guide is subject to change without notice. We cannot be held liable for
More informationDell Storage Compellent Integration Tools for VMware
Dell Storage Compellent Integration Tools for VMware Version 4.0 Administrator s Guide Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make better use of your
More informationVMware Skyline Collector Installation and Configuration Guide. VMware Skyline 1.4
VMware Skyline Collector Installation and Configuration Guide VMware Skyline 1.4 You can find the most up-to-date technical documentation on the VMware website at: https://docs.vmware.com/ If you have
More informationVMware vrealize Operations for Horizon Installation
VMware vrealize Operations for Horizon Installation vrealize Operations for Horizon 6.4 Installation vrealize Operations for Horizon 6.4 This document supports the version of each product listed and supports
More informationOpenManage Integration for VMware vcenter Quick Installation Guide for vsphere Web Client Version 3.2
OpenManage Integration for VMware vcenter Quick Installation Guide for vsphere Web Client Version 3.2 Notes, cautions, and warnings NOTE: A NOTE indicates important information that helps you make better
More informationSophos Anti-Virus standalone startup guide. For Windows and Mac OS X
Sophos Anti-Virus standalone startup guide For Windows and Mac OS X Document date: June 2007 Contents 1 What you need for installation...4 2 Installing Sophos Anti-Virus for Windows...5 3 Installing Sophos
More informationInstalling and Configuring VMware Identity Manager Connector (Windows) OCT 2018 VMware Identity Manager VMware Identity Manager 3.
Installing and Configuring VMware Identity Manager Connector 2018.8.1.0 (Windows) OCT 2018 VMware Identity Manager VMware Identity Manager 3.3 You can find the most up-to-date technical documentation on
More informationIBM Spectrum Protect Plus Version Installation and User's Guide IBM
IBM Spectrum Protect Plus Version 10.1.1 Installation and User's Guide IBM Note: Before you use this information and the product it supports, read the information in Notices on page 119. Third edition
More informationSCCM Plug-in User Guide. Version 3.0
SCCM Plug-in User Guide Version 3.0 JAMF Software, LLC 2012 JAMF Software, LLC. All rights reserved. JAMF Software has made all efforts to ensure that this guide is accurate. JAMF Software 301 4th Ave
More informationInstalling AX Server with PostgreSQL (multi-server)
Installing AX Server with PostgreSQL (multi-server) Version: 13 Published: Wednesday, November 29, 2017 ACL Services Ltd. 2017 Table of contents Table of contents Table of contents 3 Introduction 7 Intended
More informationNetScaler Analysis and Reporting. Goliath for NetScaler Installation Guide v4.0 For Deployment on VMware ESX/ESXi
NetScaler Analysis and Reporting Goliath for NetScaler Installation Guide v4.0 For Deployment on VMware ESX/ESXi (v4.0) Document Date: October 2016 www.goliathtechnologies.com 1 Legal Notices Goliath for
More informationPersonal vdisk Implementation Guide. Worldwide Technical Readiness
Worldwide Technical Readiness Table of Contents Table of Contents... 2 Overview... 3 Implementation Guide... 4 Pre-requisites... 5 Preparing PVS vdisk to be used with Personal vdisk... 6 Creating a Desktop
More informationUser guide NotifySCM Installer
User guide NotifySCM Installer TABLE OF CONTENTS 1 Overview... 3 2 Office 365 Users synchronization... 3 3 Installation... 5 4 Starting the server... 17 2 P a g e 1 OVERVIEW This user guide provides instruction
More informationVMware Horizon JMP Server Installation and Setup Guide. 13 DEC 2018 VMware Horizon 7 7.7
VMware Horizon JMP Server Installation and Setup Guide 13 DEC 2018 VMware Horizon 7 7.7 You can find the most up-to-date technical documentation on the VMware website at: https://docs.vmware.com/ If you
More informationApp Orchestration 2.0
App Orchestration 2.0 Getting Started with Citrix App Orchestration 2.0 Prepared by: Jenny Berger Commissioning Editor: Erin Smith Version: 1.0 Last Updated: April 4, 2014 Page 1 Contents Welcome to App
More informationFlexNet Manager Suite 2016 R1 SP1
FlexNet Manager Suite 2016 R1 SP1 Release Notes Updated January 2017 version 1.4 The latest release of the published Release Notes is available from the Flexera Software Customer Community (login required).
More informationVMware vrealize Operations for Horizon Installation. VMware vrealize Operations for Horizon 6.3
VMware vrealize Operations for Horizon Installation VMware vrealize Operations for Horizon 6.3 VMware vrealize Operations for Horizon Installation You can find the most up-to-date technical documentation
More informationDell EqualLogic Storage Management Pack Suite Version 5.0 For Microsoft System Center Operations Manager And Microsoft System Center Essentials
Dell EqualLogic Storage Management Pack Suite Version 5.0 For Microsoft System Center Operations Manager And Microsoft System Center Essentials Installation Guide Notes, Cautions, and Warnings NOTE: A
More informationUsing ANM With Virtual Data Centers
APPENDIXB Date: 3/8/10 This appendix describes how to integrate ANM with VMware vcenter Server, which is a third-party product for creating and managing virtual data centers. Using VMware vsphere Client,
More informationMigrating vrealize Automation 6.2 to 7.2
Migrating vrealize Automation 6.2 to 7.2 vrealize Automation 7.2 This document supports the version of each product listed and supports all subsequent versions until the document is replaced by a new edition.
More informationAntivirus Solution Guide for Clustered Data ONTAP: Symantec
Technical Report Antivirus Solution Guide for Clustered Data ONTAP: Symantec Saurabh Singh and Brahmanna Chowdary Kodavali, NetApp July 2016 TR-4304 Abstract An antivirus solution is key for enterprises
More informationPrivileged Identity App Launcher and Session Recording
Privileged Identity App Launcher and Session Recording 2018 Bomgar Corporation. All rights reserved worldwide. BOMGAR and the BOMGAR logo are trademarks of Bomgar Corporation; other trademarks shown are
More informationDeploying HP SIM 6.x on MSCS clusters on Windows 2008 with SQL Server 2008 SP1 White Paper
Deploying HP SIM 6.x on MSCS clusters on Windows 2008 with SQL Server 2008 SP1 White Paper Table of Contents Abstract... 2 Introduction... 2 System infrastructure... 3 Storage configuration... 3 IP addresses...
More informationSophos Enterprise Console advanced startup guide
Sophos Enterprise Console advanced startup guide For distributed installations Product version: 5.3 Document date: April 2015 Contents 1 About this guide...4 2 Planning installation...5 2.1 Planning the
More informationSilk Performance Manager Installation and Setup Help
Silk Performance Manager 18.5 Installation and Setup Help Micro Focus The Lawn 22-30 Old Bath Road Newbury, Berkshire RG14 1QN UK http://www.microfocus.com Copyright 2004-2017 Micro Focus. All rights reserved.
More informationMerchandising Server 2.2
Merchandising Server 2.2 2014-12-07 04:31:45 UTC 2014 Citrix Systems, Inc. All rights reserved. Terms of Use Trademarks Privacy Statement Contents Merchandising Server 2.2... 5 About... 6 System Requirements
More informationCitrix SCOM Management Pack 1.4 for ShareFile
Citrix SCOM Management Pack 1.4 for ShareFile Nov 27, 2017 Citrix SCOM Management Pack for ShareFile is an availability and performance management solution that extends end-toend service monitoring capabilities
More informationForeScout CounterACT. Plugin. Configuration Guide. Version 2.1
ForeScout CounterACT Hybrid Cloud Module: VMware vsphere Plugin Version 2.1 Table of Contents About VMware vsphere Integration... 4 Use Cases... 4 Additional VMware Documentation... 4 About this Plugin...
More informationTable of Contents. Configure and Manage Logging in to the Management Portal Verify and Trust Certificates
Table of Contents Configure and Manage Logging in to the Management Portal Verify and Trust Certificates Configure System Settings Add Cloud Administrators Add Viewers, Developers, or DevOps Administrators
More informationQualys Cloud Platform (VM, PC) v8.x Release Notes
Qualys Cloud Platform (VM, PC) v8.x Release Notes Version 8.16 December 14, 2018 This new release of the Qualys Cloud Platform (VM, PC) includes improvements to Vulnerability Management and Policy Compliance.
More informationGetting Started with ESX Server 3i Installable Update 2 and later for ESX Server 3i version 3.5 Installable and VirtualCenter 2.5
Getting Started with ESX Server 3i Installable Update 2 and later for ESX Server 3i version 3.5 Installable and VirtualCenter 2.5 Getting Started with ESX Server 3i Installable Revision: 20090313 Item:
More informationENTRUST CONNECTOR Installation and Configuration Guide Version April 21, 2017
ENTRUST CONNECTOR Installation and Configuration Guide Version 0.5.1 April 21, 2017 2017 CygnaCom Solutions, Inc. All rights reserved. Contents What is Entrust Connector... 4 Installation... 5 Prerequisites...
More informationVMware vrealize Operations for Horizon Installation. VMware vrealize Operations for Horizon 6.5
VMware vrealize Operations for Horizon Installation VMware vrealize Operations for Horizon 6.5 You can find the most up-to-date technical documentation on the VMware website at: https://docs.vmware.com/
More informationMigrating vrealize Automation 6.2 to 7.1
Migrating vrealize Automation 6.2 to 7.1 vrealize Automation 7.1 This document supports the version of each product listed and supports all subsequent versions until the document is replaced by a new edition.
More informationAbout Retrieve 3. Installing DocuSign Retrieve 4. Logging on to DocuSign 6
Quick Start Guide DocuSign Retrieve 3.3 May 2018 Rev A Overview DocuSign Retrieve is a windows-based tool that "retrieves" envelopes, documents, and data from DocuSign for use in external systems. Retrieve
More informationvapp Deployment and Configuration Guide
vapp Deployment and Configuration Guide vcenter Operations Manager 5.8.5 This document supports the version of each product listed and supports all subsequent versions until the document is replaced by
More informationDell EMC vsan Ready Nodes for VDI
Dell EMC vsan Ready Nodes for VDI Integration of VMware Horizon on Dell EMC vsan Ready Nodes April 2018 H17030.1 Deployment Guide Abstract This deployment guide provides instructions for deploying VMware
More informationSOA Software Intermediary for Microsoft : Install Guide
SOA Software Intermediary for Microsoft : Install Guide SOA Software Intermediary for Microsoft Install Guide SOAIM_60 August 2013 Copyright Copyright 2013 SOA Software, Inc. All rights reserved. Trademarks
More informationEndpoint Manager for Mobile Devices Setup Guide
Endpoint Manager for Mobile Devices Setup Guide ii Endpoint Manager for Mobile Devices Setup Guide Contents IBM Endpoint Manager for Mobile Devices Setup Guide......... 1 Components.............. 1 Architecture..............
More informationBest Practices for Configuring the Dell Compellent SMI-S Provider for Microsoft SCVMM 2012
Dell Compellent Storage Center Best Practices for Configuring the Dell Compellent SMI-S Provider for Microsoft SCVMM 2012 Document Revisions Date Revision Comments 04/11/2012 A First Revision THIS BEST
More informationVMware Enterprise Systems Connector Installation and Configuration. JULY 2018 VMware Identity Manager 3.2 VMware Identity Manager VMware AirWatch 9.
VMware Enterprise Systems Connector Installation and Configuration JULY 2018 VMware Identity Manager 3.2 VMware Identity Manager VMware AirWatch 9.3 You can find the most up-to-date technical documentation
More informationPHD Virtual Backup Exporter. version 6.5 Users Guide. Document Release Date: August 26,
PHD Virtual Backup Exporter version 6.5 Users Guide Document Release Date: August 26, 2013 www.phdvirtual.com i PHD Virtual Backup Exporter - Users Guide Legal Notices PHD Virtual Backup Exporter Users
More information