Version-E Manual PR1a. Photocell. Manual. Page 1
|
|
- Colleen Cox
- 5 years ago
- Views:
Transcription
1 Version-E Photocell Manual Page 1
2 Important Information General Before using your ALGE-TIMING device read the complete manual carefully. It is part of the device and contains important information about installation, safety and its intended use. This manual cannot cover all conceivable applications. For further information or in case of problems that are mentioned not at all or not sufficiently detailed, please contact your ALGE-TIMING representative. You can find contact details on our homepage Safety Apart from the information of this manual all general safety and accident prevention regulations of the legislator must be taken into account. The device must only be used by trained persons. The setting-up and installation must only be executed according to the manufacturer s data. Intended Use The device must only be used for its intended applications. Technical modifications and any misuse are prohibited because of the risks involved! ALGE-TIMING is not liable for damages that are caused by improper use or incorrect operation. Cleaning Please clean the outside of the device only with a smooth cloth. Detergents can cause damage. Never submerge in water, never open or clean with wet cloth. The cleaning must not be carried out by hose or high-pressure (risk of short circuits or other damage). Liability Limitations All technical information, data and information for installation and operation correspond to the latest status at time of printing and are made in all conscience considering our past experience and knowledge. Information, pictures and description do not entitle to base any claims. The manufacturer is not liable for damage due to failure to observe the manual, improper use, incorrect repairs, technical modifications, use of unauthorized spare parts. Translations are made in all conscience. We assume no liability for translation mistakes, even if the translation is carried out by us or on our behalf. Disposal If a label is placed on the device showing a crossed out dustbin on wheels (see drawing), the European directive 2002/96/EG applies for this device. Please get informed about the applicable regulations for separate collection of electrical and electronical waste in your country and do not dispose of the old devices as household waste. Correct disposal of old equipment protects the environment and humans against negative consequences! Copyright by ALGE-TIMING GmbH All rights reserved. Any duplication, either in full or in part, requires the prior written consent of the copyright holder. Page 2
3 Declaration of Conformity We declare that the following products comply with the requirements of the listed standards. We, ALGE-TIMING GmbH Rotkreuzstrasse 39 A-6890 Lustenau Declare under our sole responsibility, that the: Photocell is in conformity with the following standard(s) or other normative documents(s): Safety: EN : A11:2009 EMC: EN55022:2006+A1:2007 EN55024:1998+A1:2001+A2:2003 EN : A1: A2:2009 EN :2008 Additional Information: The product herewith complies with the requirements of the Low Voltage Directive 73/23/EEC, also the EMC Directive 2004/108EG and accordingly carries the CE-marking. Lustenau, ALGE-TIMING GmbH Albert Vetter (General Manager) Page 3
4 Page 4 Manual
5 Contents 1 General Functionality Photocell Features Type of photocell Reflection photocell -R: Reflection photocell -RT: One-way photocell -d: One-way photocell -dt: Operating Modes Reflection Photocell NORM One-way Photocell Power Supply External supply from ALGE timing devices External Supply Internal Battery Insert Batteries Operating Time of Batteries Operating Mode Indication with LED Alignment of Photocell Reflection Photocell One-way Photocell Setting of Dead Time Synchronisation of two Photocells Weather protection Technical Data Page 5
6 1 General Manual The photocell combines highest precision and performance with smallest dimensions. 1.1 Functionality The photocell transmitter sends a modulated light beam in infrared range. The receiver monitors the light beam for disruptions. In case of a disruption of the infrared beam the receiver releases a pulse. For multipurpose use the photocell can be operated in three different operation modes: reflection photocell, transmitter and receiver. 1.2 Photocell Features Releasing accuracy 1/ second Diversity of types: Reflection photocell One-way photocell for large distances Large photocell range: Reflection photocell approx. 25 m Transmitter and receiver photocell more than 150 m Variable supply of the photocell: Battery operation Supply from ALGE timing device External supply from 4 to 18 VDC Battery condition indication with LED (green, yellow, red) Indication of the photocell alignment with LED (green, yellow, red) Synchronisation of two photocells (main and backup), to prevent interferences Setting of dead time (approx. 20 ms to 2 s /factory setting = 20 ms) 1.3 Types of photocell According to its type the photocell can consist of the following parts: Photocell Reflector -Ref Mounting bracket BBG Tripod TRI128 Photocell cable Photocell cable Page 6
7 Additional photocell accessory: Carrying case for photocell(s) and/or other accessory Two-core photocell cable with banana plug (different lengths) Cable reel with two-core steel cable with banana plug and/or banana socket Lengths: KT120 (120 m), KT150 (150 m), KT300 (300 m), KT500 (500 m) Charging set including 4 NiMH rechargeable batteries for photocell Reflector with centered screw hole (for mounting at wooden pole) Reflector with adhesive tape (for fixed reflector) Synchronisation cable for 2 photocells Reflection photocell -R: In case transmitter and receiver are in one case, we refer to a reflection or two-way photocell. The light beam is aimed from transmitter to a reflector. The reflector works like a mirror and reflects the light beam to the receiver. Range: approx. 25 m Photocell set: 1 x, 1 x -Ref, 2 x BBG, 1 x (10m) Reflection photocell -RT: Same as reflection photocell -R, without mounting brackets BBG but with tripods and 30 m photocell cable. Range: approx. 24 m Photocell set: 1 x, 1 x -Ref, 2 x TRI128, 1 x (30 m) One-way photocell -d: The one-way photocell consists of separate transmitter and receiver. The light beam is aimed directly from transmitter to receiver. Range: more than 150 m Photocell set: 2 x, 2 x BBG, 1 x (10 m) One-way photocell -dt: Same as one-way photocell -d, without mounting brackets BBG but with tripods and 30 m photocell cable. Range: more than 150 m Photocell set: 2 x, 2 x TRI128, 1 x (30 m) 2 Operating Modes The photocell can be used in different operating modes. Reflection photocell Transmitter photocell TX Receiver photocell RX 2.1 Reflection Photocell NORM The reflection photocell sends from the transmitter an infrared light beam that is reflected by the reflector and analized by the receiver. The maximum range of the photocell is 25 m (distance between photocell and reflector). This photocell requires the following parts: Photocell (Switch setting NORM) Reflector -Ref Page 7
8 2.2 One-way Photocell For a working photocell set a transmitter (switch setting TX) and a receiver (switch setting RX see below) is needed. The transmitter sends an infrared light beam to the receiver. The maximum range is approx. 150 m. 3 Power Supply The photocell can be supplied in different ways. The easiest supply is carried out with the included cable (or ) directly from the ALGE timing device. In case the photocell is far away from the timing device it can also be supplied externally (4 18 VDC) or with batteries (2 x AA battery in photocell). Current consumption: battery with 2,5 VDC: ma timing devices 5 Vstab: 9-20 ma Connector pin assignment DIN socket: 1... signal output 2... signal output 3... ground 4... external supply (input 4-18 VDC) 5... external supply (+5VDC stabilized e.g. from ALGE timing devices) 3.1 External supply from ALGE timing devices For a supply from the ALGE timing device use the photocell cable 001 (red) and/or 002 (green). The ALGE timing device supplies a stabilized voltage of 5 VDC (pin 5). ATTENTION: The cable length is limited to approx. 100 m as otherwise the voltage drop would be too high. 3.2 External Supply The photocell can be supplied by pin 4 (4 18 VDC) and pin 3 (ground). This is primarily of advantage when several photocells have to be supplied by cable over large distance. 3.3 Internal Battery The photocell can also be supplied by internal batteries (2 x AA battery). The following types of batteries can be used: Alkaline battery: Ideal in case the photocell is not used very often. NiMH rechargeable batteries: Rechargeable batteries that are optimal in case the photocell is used daily. These batteries have a long operating time with very low temperatures. NiCd rechargeable batteries: Not recommended for use in photocell. Page 8
9 Switch on internal battery The battery in the photocell is switched on with switch (on/off) Insert Batteries The battery cover is underneath the photocell Press cover slightly inside and pull forward Attention: Mind the polarity of the batteries! (sticker inside) Operating Time of Batteries The operating time of the photocell depends on different factors. Most importantly is what kind of battery is used. The operating time becomes less with each additional photocell pulse. Also important is whether the photocell is used as reflection photocell (transmitter and receiver) and/or as transmitter or receiver. Reflection photocell Battery type 1 Pulse per minute -20 C 20 C Alkaline Battery 2,8 Ah approx. 17 h approx. 77 h. NiCd rechargeable b. - 1,1 Ah approx. 11 h approx. 28 h NiMH rechargeable b. - 2,7 Ah approx. 57 h approx. 70 h If the photocell is used as a transmitter it almost has the same operating time as in reflection photocell mode; for a receiver it is three times higher as for the reflection photocell. 4 Operating Mode Indication with LED The LED of the photocell indicates several operating modes: LED Operating mode NORM Operating mode RX Operating mode TX permanently red Photocell misaligned Photocell misaligned No indication permanently yellow permanently green blinking red blinking yellow Photocell not optimally aligned Photocell optimally aligend Battery empty replace Battery near empty replace soon Photocell not optimally aligend Photocell optimally aligned Battery empty replace Battery near empty replace soon No indication No indication Battery empty replace Battery near empty replace soon blinking green Battery full Battery full Battery full Page 9
10 5 Alignment of Photocell 5.1 Reflection Photocell Screw mounting brackets BBG to wooden pole and/or position tripods TRI128 Screw photocell and reflector to mounting brackets and/or tripods Align mirror of reflector straight to photocell Switch operating mode to <NORM> Switch on photocell: Batteries: Switch to <On> Supply from timing device: connect cable of timing device with photocell (red cable 001-xx or green cable 002-xx), switch on timing device External supply: connect external supply to photocell Operating mode LED must flash red Locate the reflector with the alignment notch Align the photocell until the operating mode LED flashes green After 5 seconds the operating mode LED has to blink green (indicates that the battery and/or supply is okay). In case the LED blinks orange or red the battery should be replaced or the supply must be checked. After each photocell pulse the operating mode LED flashes green for several seconds (indication for good photocell reception) before the battery condition is indicated again. 5.2 One-way Photocell Screw mounting brackets BBG to wooden pole and/or position tripods TRI128 Screw photocells to mounting brackets and/or tripods Align photocells to each other Check if the operating mode is <NORM>. If not, switch to this position. Switch on photocells: Batteries: Switch to <On> Supply from timing device: connect cable of timing device with photocells (red cable 001-xx or green cable 002-xx), switch on timing device External supply: connect external supply to photocells Operating mode LED must flash red Locate the other photocell with the alignment notch Align the photocell until the operating mode LED flashes green After 5 seconds the operating mode LED has to blink green (indicates that the battery and/or supply is okay). In case the LED blinks orange or red the battery should be replaced or the supply must be checked. Switch operating mode of transmitter photocell to TX - LED has to blink green, if supply is okay. Switch operating mode of receiver photocell to RX LED works like the one of the reflection photocell. After each photocell pulse the operating mode LED of the receiver photocell flashes green for several seconds (indication for good photocell reception) before the battery condition is indicated again. Attention: The timing device has to be connected to the receiver photocell. Page 10
11 5.3 Setting of Dead Time We recommend to set the dead time, if possible, at the timing device. At the factory, the dead time of the photocell is set to the least dead time (20 ms). The dead time can be set with a screwdriver between 20 and 2000 ms. For this, you first have to pull out the weather protection. Definition of dead time: The dead time is the time during which the photocell is blocked after a photocell pulse. It starts at that point when the light beam is no longer disrupted. This is necessary to prevent multiple releases. With this potentiometer the dead time can be set between 20 and 2000 ms 5.4 Synchronisation of two Photocells For using two photocells in parallel as system A and B, they should be synchronized. By synchronization one photocell sets the cycle for the infrared pulses. By this it is guaranteed that the photocells do not interfere each other. Connect cable to both photocells. The LED of the photocell that sets the synchronisation cycle flashes. 6 Weather protection The weather protection can be pulled out. With pulled out weather protection the lenses are protected from snow and rain. If the photocell is used on a glacier it is essential to pull out the weather protection. Otherwise the increased UV radiation can cause interferences. Pull out weather protection Attention: Direct solar radiation through the lense into the photocell has to be prevented by all means. Direct solar radiation through the lense can damage the photocell (burning glass effect). Page 11
12 7 Technical Data Range with reflector: Range with transmitter and receiver: Pulse output: Maximum output load: Reaction time: Pulse length: Dimensions (without ball joint): Weight : Weight -Ref: Switch: Selector switch: Power supply: 0.5 to 25 meter 0 to over 150 meter NPN Transistor, Open Collector, activ low max. 250mW max. 14V max. 100mA 300 µs, 1 ms set permanently 20 bis 2000 ms adjustable (dead time) approx. 118 x 87 x 44 mm approx. 0.3 kg approx. 0.2 kg On/Off switch for battery for Norm, TX and RX from ALGE timing device: 5 VDC stabilized external supply: 4-18 VDC internal battery: 2 x AA batteries Power consumption: battery with 2.5 VDC: ma timing device with 5 Vstab: 9-20 ma Connector pin assignment DIN socket: 1... signal output 2... signal output 3... ground 4... external supply (input 4-18 VDC) 5... external supply (+5VDC stabilized e.g. from ALGE timing devices) Subject to changes Copyright by ALGE-TIMING GmbH Rotkreuzstr Lustenau / Austria Page 12
Version-E Manual
Version-E160401 Manual Important Information General Before using your ALGE-TIMING device read the complete manual carefully. It is part of the device and contains important information about installation,
More informationVersion-E Version-E Manual
Version-E160221 Version-E090203 Manual Important Information General Before using your ALGE-TIMING device read the complete manual carefully. It is part of the device and contains important information
More informationVersion-E Soccer and American Football. Manual
Version-E181025 Soccer and American Football Manual Important Information General Manual Before using your ALGE-TIMING device read the complete manual carefully. It is part of the device and contains important
More informationVersion-E Manual LDU3000/3000A
Version-E121024 Manual Important Information General Before using your ALGE-TIMING device read the complete manual carefully. It is part of the device and contains important information about installation,
More informationVersion-E Manual
Version-E160705 Important Information General Before using your ALGE-TIMING device read the complete manual carefully. It is part of the device and contains important information about installation, safety
More informationD-RTNM xxxx, D-IDxxx, D-GDxxx V Manual
D-RTNM xxxx, D-IDxxx, D-GDxxx V140227 Manual Important Information General Before using your ALGE-TIMING device read the complete manual carefully. It is part of the device and contains important information
More informationD-RTNM xxxx, D-IDxxx, D-GDxxx Manual
D-RTNM xxxx, D-IDxxx, D-GDxxx Manual Important Information General Before using your ALGE-TIMING device read the complete manual carefully. It is part of the device and contains important information about
More informationLED W RGBA User Manual
LED- 245-1W RGBA User Manual Please read the instructions carefully before use CONTENTS 1. Safety Instructions...2 2. Technical Specifications...3 3. How To Set The Unit...4 3.1 Control Panel...4 3.2 Main
More informationLSL250. Laser light! Do not stare into the beam or view directly with magnifiers. Class 2 laser EN :
Lufkin LSL250 Professional rotary laser in extremely rugged design horizontal levelling even under tough conditions. Automatic rotary laser 635 nm, self-levelling range ± 5 horizontal, accuracy 1 mm /
More informationSAMURAI SCAN 50 LED-SC50D. User Guide. Innovation, Quality, Performance. Professional Entertainment Technology 19-
SAMURAI SCAN 50 LED-SC50D Innovation, Quality, Performance User Guide Professional Entertainment Technology 19- EC Declaration of Conformity We declare that our products (lighting equipments) comply with
More informationInstallation manual plugs and connectors with screw connection (16/32 A)
EN Installation manual plugs and connectors with screw connection (16/32 60003213 Issue 04.2016 2016-04-01 Table of contents 1 About this manual 3 1.1 Structure of the warnings 3 1.2 Symbols used 4 1.3
More informationLED PANEL. User Manual Please read the instructions carefully before use LED-7TC. Innovation, Quality, Performance 15-
LED PANEL LED-7TC Innovation, Quality, Performance User Manual Please read the instructions carefully before use 15- 9. Fixture Cleaning TABLE OF CONTENTS 1. Safety Instructions 2. Technical Specifications
More informationPKP Prozessmesstechnik GmbH. Borsigstrasse 24. D Wiesbaden-Nordenstadt. Tel: / Fax: / Operating manual PSA06
PKP Prozessmesstechnik GmbH Borsigstrasse 24 D-65205 Wiesbaden-Nordenstadt Tel: 06122 / 7055-0 Fax: 06122 / 7055 50 Operating manual PSA06 Electronical pressure switch Content Page 19-34 1. Foreword 19
More informationIndustriefunkuhren. Technical Manual. Signal Converter. for DIN Rail Mounting Series 4800xx-yy ENGLISH
Industriefunkuhren Technical Manual Signal Converter for DIN Rail Mounting Series 4800xx-yy ENGLISH Version: 01.01-19.07.2007 2 / 23 Signal Converter 4800 - V01.01 INPORTANT NOTES Downloading Technical
More informationIntroduction. 1. RF Module
Introduction RISCO Groupʹs 2 Way Wireless I/O & X10 Module is an extension module enabling wired devices to be connected to the Agility Wireless system. The Wireless I/O Module supports 4 hardwired zones,
More informationHI ma Simulator
Instruction Manual HI 931002 4-20 ma Simulator http://www.hannainst.com These Instruments are in Compliance with the CE Directives Dear Customer, Thank you for choosing a Hanna Instruments Product. Please
More informationSKIVING MACHINE MAINTENANCE & INSTRUCTIONS MANUAL ASSK2. Allswage UK. Roebuck Street, West Bromwich, B70 6RB
SKIVING MACHINE ASSK2 MAINTENANCE & INSTRUCTIONS MANUAL A. WARRANTY AND RESPONSIBILITY Warranty: It's the supplier's responsibility to guarantee the conformity of the product, assuring that it's manufactured
More informationLED PANEL. User Manual Please read the instructions carefully before use LED-212RGB TABLE OF CONTENTS. 1. Safety Instructions
TABLE OF CONTENTS LED PANEL 1. Safety Instructions 2. Technical Specifications 3. Installation 4. How to set the unit 5. How to control the fixture 6. DMX512 Configuration 7. DMX512 Connections 8. Troubleshooting
More informationSize: 84 x 118.4mm * 100P
Size: 84 x 118.4mm * 100P *, ( ), ( ) *, According to the European WEEE directive, electrical and electronic equipment must not be disposed with consumers waste. Its components must be recycled or disposed
More informationicore Kiosk system Installation Guide
icore Kiosk system Installation Guide The reproduction, transmission or use of this document or its contents is not permitted without express authority. Offenders will be liable for damages. All rights,
More informationECOLINE EL 515 PLUS EL 515 PLUS SET
DE FR ECOLINE EL 55 PLUS EL 55 PLUS SET BEDIUNGSANLEITUNG USER MANUAL MODE D EMPLOI EXACTLY WHAT YOU NEED. Rotating laser EL 55 Plus is available as laser unit with standard accessories as well as rotating
More informationHI ma Simulator
Instruction Manual HI 931002 4-20 ma Simulator http://www.hannacan.com These Instruments are in Compliance with the CE Directives Dear Customer, Thank you for choosing a Hanna Instruments Product. Please
More informationOperating Manual UMB ISO Converter ISOCON Order Number: 8160.UISO
Order Number: 8160.UISO Status: V3; 17.09.2010c G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany 1 TABLE OF CONTENTS PLEASE READ BEFORE USE... 3 DESCRIPTION... 5 UMB ISO CONVERTER ISOCON... 6 CONFIGURATION...
More informationFlow Sensor SONOFLOW CO.55
Flow Sensor SONOFLOW CO.55 Operating Manual Device: Model: Type: Flow Sensor SONOFLOW CO.55 Manufacturer: SONOTEC Ultraschallsensorik Halle GmbH Nauendorfer Str. 2 06112 Halle (Saale), Germany Phone: +49
More informationOperating Manual. Radio Remote Control System. Edition 04/2007 US, Version A001, Excalibur, Subject to Technical Changes Page: 1
Operating Manual Radio Remote Control System Edition 04/2007 US, Version A001, Excalibur, Subject to Technical Changes Page: 1 Cattron-Group International. 58 West Shenango Street Sharpsville, PA 16150
More informationRetro-reflective photoelectric sensors. Dimensioned drawing. Receiver Transmitter Optical axis LED yellow 90 turning connector. Electrical connection
IPRK 8 Retro-reflective photoelectric sensors Dimensioned drawing 0.05 8m A 2 LS A²LS - active suppression of extraneous light Integrated AS-i slave M12 turning connector or cable connection Visible red
More informationLynx Pro Audio S.L. Valencia, Spain
HR-Series USER MANUAL V.16.05 Lynx Pro Audio S.L. Valencia, Spain - www.lynxproaudio.com - info@lynxproaudio.com INTRODUCTION To facilitate the correct and reliable use of the HR cabinets we have designed
More informationProfessional Entertainment Technology. imove 50SR. Innovation, Quality, Performance 21-
Innovation, Quality, Performance 21- imove 50SR User Guide Professional Entertainment Technology EC Declaration of Conformity We declare that our products (lighting equipments) comply with the following
More informationOperating instructions Safe AS-i input module ASIM-C-M About this document. Content
7 Set-up and maintenance 7.1 Functional testing....10 7.2 Maintenance...10 EN Operating instructions.............pages 1 to 6 Original 8 Disassembly and disposal 8.1 Disassembly....10 8.2 Disposal...10
More informationenglish S-5EC Potentiometer 5-step Operating Instructions Keep for reference! L-BAL-E265-GB 1608 Index 002
S-5EC english Potentiometer 5-step Operating Instructions Keep for reference! Content 1 General notes............................................ 3 1.1 Structure of the operating instructions....................
More informationSLIMBAT2 wireless photocell MANUAL
v.1.1 1. of the device The wireless photocell is a safety element in gate automation. Between the transmitter and the receiver, the infrared beam is created, forming invisible to the human eye barrier.
More informationGREISINGER electronic GmbH. D Regenstauf, Hans-Sachs-Straße 26. T-Logg 120 W -... T-Logg 120 K -...
E39.0.1X.6C-01 Data logger for standard signals as of version 1.0 Operating Instruction T-Logg 120... T-Logg 120 W -... T-Logg 120 K -... GREISINGER electronic GmbH D - 93128 Regenstauf, Hans-Sachs-Straße
More informationDual channel temperature logger with two voltage inputs 0-5V Instruction Manual
LOGGER S0541 Dual channel temperature logger with two voltage inputs 0-5V Instruction Manual Instruction Manual for use of S0541 logger Instrument is designed for measurement and record of temperature
More informationLED BEAM 300 LED-MB50. User. Guide. Professional Entertainment Technology
LED BEAM 300 LED-MB50 Guide User Professional Entertainment Technology TABLE OF CONTENTS 1. Safety Instruction 2. Technical Specification 3. How To Set The Unit 4. How To Control The Unit 5. Troubleshooting
More informationProfessional Entertainment Technology LED BEAM 300 LED-MB50. Innovation, Quality, Performance 23-
Innovation, Quality, Performance 23- LED BEAM 300 LED-MB50 User Guide Professional Entertainment Technology EC Declaration of Conformity We declare that our products (lighting equipments) comply with the
More informationPlease read the instructions carefully before use LED PYRAMID LED-904D. Innovation, Quality, Performance 15-
Innovation, Quality, Performance 15- LED PYRAMID LED-904D User Manual Please read the instructions carefully before use Innovation, Quality, Performance 15- LED PYRAMID LED-904D User Manual Please read
More informationLED-Illumination with Control Unit Ident.-No
A HAAG-STREIT COMPANY MÖLLER-WEDEL OPTICAL GmbH, Rosengarten 10, D-22880 Wedel with Control Unit Ident.-No. 773 190 01 Valid from Hardware / Software Rev. / SN 1.0 IDENT.-NO. 217 321 09 Document Version
More informationINSPECTION CAMERA MODEL NO: CIC2410 OPERATION & SAFETY INSTRUCTIONS PART NO: GC0116
INSPECTION CAMERA MODEL NO: CIC2410 PART NO: 6470385 OPERATION & SAFETY INSTRUCTIONS GC0116 INTRODUCTION Thank you for purchasing this CLARKE Inspection Camera. Before attempting to use this product, please
More informationUser Manual TL-TP70-HDC 70m HDBaseT Extender Set for HDMI, RS232 & IR All Rights Reserved Version: TL-TP70-HDC _160926
User Manual TL-TP70-HDC 70m HDBaseT Extender Set for HDMI, RS232 & IR All Rights Reserved Version: TL-TP70-HDC _160926 Preface Read this user manual carefully before using this product. Pictures shown
More informationTB-1230 QW. User Manual Please read the instruc on carefully before use
TB-1230 QW User Manual Please read the instruc on carefully before use CONTENTS 1. Safety Instructions... 2 2. Technical Specifications... 3 3. How To Set The Unit... 4 3.1 Control panel... 4 3.2 Main
More informationIRB-RET O P E R A T I N G I N S T R U C T I O N S UNIVERSAL SAFETY RETROREFLECTIVE PHOTOEYE U L MONITORED DEVICE
O P E R A T I N G I N S T R U C T I O N S IRB-RET UNIVERSAL SAFETY RETROREFLECTIVE PHOTOEYE U L 3 2 5-2 0 1 6 MONITORED DEVICE 4564 Johnston Parkway, Cleveland, Ohio 44128 P. 800 426 9912 F. 216 518 9884
More informationManual. Infrared cameras. Contour M
Manual Infrared cameras Contour M Content Content... 2 Safety requirements... 3 About... 4 Operation... 5 The Maintenance instruction... 7 Spectral sensitivity... 7 Power density... 8 Technical information...
More informationGREISINGER electronic GmbH D Regenstauf, Hans-Sachs-Straße 26
E39.0.31.6C-02 Data logger for humidity temperature as of version V1.0 Operating Manual T-Logg 160 GREISINGER electronic GmbH D - 93128 Regenstauf, Hans-Sachs-Straße 26 +49 (0) 9402 / 9383-0 +49 (0) 9402
More informationTable of Contents UK/ N. IRELAND HELPLINE REP. IRELAND HELPLINE
Table of Contents Table of Contents... 1 Safety and Maintenance... 3 Safety Instructions...3 Operational Safety...3 Point of Use...3 Electro-Magnetic Compatibility...4 Information of Conformity...4 Battery
More informationIRB-RET O P E R A T I N G I N S T R U C T I O N S UNIVERSAL SAFETY RETROREFLECTIVE PHOTOEYE U L M O N I T O R E D DEVICE
O P E R A T I N G I N S T R U C T I O N S IRB-RET UNIVERSAL SAFETY RETROREFLECTIVE PHOTOEYE U L 3 2 5-2 0 1 6 M O N I T O R E D DEVICE 4564 Johnston Parkway, Cleveland, Ohio 44128 P. 800 426 9912 F. 216
More informationPQ V ac. CONTROL PANEL 230V FOR ROLLING SHUTTERS Instructions Manual. Control panel for electric rolling shutters 230Vac TECHNICAL FEATURES
CONTROL PANEL 230V FOR ROLLING SHUTTERS Instructions Manual Q45 230V ac Control panel for electric rolling shutters 230Vac Built-in radio receiver 433Mhz Adjustable pause time for automatic closing function
More informationUser Manual Please read the instructions carefully before use
!!! "#$%!&'(!$)*! $+)'!&'(!$)*!! LED-3082 RGB LED-3084 RGB Innovation, Quality, Performance User Manual Please read the instructions carefully before use 15A TABLE OF CONTENTS 1. Safety Instructions 2.
More informationENGLISH General information
Opener User Guide Congratulations for having purchased the iblue Smart Gate product. Please read this User Guide carefully before installing and starting to use the product. The product package includes
More informationLED Colour Flood 10W / 30W RGB LED floodlight. user manual
LED Colour Flood 10W / 30W RGB LED floodlight user manual Musikhaus Thomann e.k. Treppendorf 30 96138 Burgebrach Germany Telephone: +49 (0) 9546 9223-0 E-mail: info@thomann.de Internet: www.thomann.de
More informationProfessional Entertainment Technology LED BEAM 300 LED-MB50. User. Guide
Professional Entertainment Technology LED BEAM 300 LED-MB50 Guide User 1- 1. Safety Instruction WARNING Please read carefully the instruction, which includes important information about the installation,
More informationCRM Control Panel and Weather Detection System CRM3 for DC actuators (part # 40821J) CRM4 for AC actuators (part # 40822K)
CRM Control Panel and Weather Detection System CRM3 for DC actuators (part # 40821J) CRM4 for AC actuators (part # 40822K) CRM Applications CRM includes a control relay box and a power supply; additional
More informationSPECTANO 100. Quick Start Guide. Smart Measurement Solutions
SPECTANO 100 Quick Start Guide Smart Measurement Solutions Contents Contents 1 About this Quick Start Guide.....................................2 Safety symbols used..............................................
More informationOperating instructions. Switching amplifier DN0210 DN / / 2015
Operating instructions Switching amplifier DN0210 DN0220 UK 80011079 / 00 01 / 2015 Contents 1 Preliminary note...4 1.1 Symbols used...4 1.2 Warning signs used...4 2 Safety instructions...5 2.1 General...5
More informationOPERATING INSTRUCTIONS 7 SERIES STATIC GENERATORS
OPERATING INSTRUCTIONS 7 SERIES STATIC GENERATORS GB Contents Page 1 Introduction 4 2 Safety 5 3 Use 6 4 Checking on Delivered Equipment 6 5 General Specification and Dimensions 7 6 Positioning 10 7 Operating
More informationModel DT-315P DIGITAL STROBOSCOPE INSTRUCTION MANUAL
Model DT-315P DIGITAL STROBOSCOPE INSTRUCTION MANUAL 1. CAUTION * Do not operate or store in the following places: 1. Explosive areas 2. Places where water, oil, chemicals, or dust, etc. exists 3. Places
More informationInstallation Guide. QBox-V6. Standalone/Spare V6 SDI QBox. Standalone/Spare V6 SDI QBox. Part No. A
Installation Guide Standalone/Spare V6 SDI QBox QBox-V6 Standalone/Spare V6 SDI QBox Part No. A9009-0004 EN www.autocue.com Copyright 2017 All rights reserved. Original Instructions: English All rights
More informationGREISINGER electronic GmbH. D Regenstauf, Hans-Sachs-Straße 26. T-Logg 100. T-Logg 100 E
E39.0.0X.6C-03 Data logger for temperature as of version V1.3 Operating Manual T-Logg 100 T-Logg 100 T-Logg 100 E GREISINGER electronic GmbH D - 93128 Regenstauf, Hans-Sachs-Straße 26 +49 (0) 9402 / 9383-0
More information2-Way Wireless I/O Expander Installation Guide
2-Way Wireless I/O Expander Installation Guide For more detailed information please refer to the iconnect Installer Manual provided on our website: www.electronics-line.com Table of Contents 1. Introduction...
More informationOperating instructions
www.lehmann-locks.com GB (M400 TA) Type M400 TA Electronic: MAIICBM4 Type M400 TA Keypad: SLIICBB1 M400 Keypad lock Operating instructions Contents Page General description, mode of operation... Safety
More informationAR10S-MF AR11S-MF AR40S-MF AR41S-MF Installation manual for mounting and connecting. Siemens AB. Version 5.0 A Security Products
AR10S-MF AR11S-MF AR40S-MF AR41S-MF Installation manual for mounting and connecting Version.0 06.09.2013 Security Products Copyright Copyright Technical specifications and availability subject to change
More informationMD4 esata. 4-Bay Rack Mount Chassis. User Manual February 6, v1.0
4-Bay Rack Mount Chassis User Manual February 6, 2009 - v1.0 EN Introduction 1 Introduction 1.1 System Requirements 1.1.1 PC Requirements Minimum Intel Pentium III CPU 500MHz, 128MB RAM esata equipped
More informationSelf-leveling Laser Marker (4V1HXL)
Self-leveling Laser Marker (4V1HXL) Congratulations on your choice of this Self-leveling Laser Marker. For the purpose of long-term use of this instrument, we suggest you to read this instruction manual
More informationOperating and Installation Manual. EASYLAB Expansion modules Type EM-TRF for 230 V AC mains voltage
Operating and Installation Manual EASYLAB Expansion modules Type EM-TRF for 230 V AC mains voltage Type EM-TRF-USV for 230 V AC mains voltage; provides uninterruptible power supply (UPS) The art of handling
More informationOperating Instructions Differential Pressure Transducer PS27
Operating Instructions Differential Pressure Transducer PS27 halstrup-walcher GmbH Stegener Straße 10 79199 Kirchzarten/Germany Phone: +49 (0) 76 61/39 63 0 Fax: +49 (0) 76 61/39 63 99 E-mail: info@halstrup-walcher.com
More informationOperating Instructions for Low Volume Rotating Vane Flow Meter. Model: DPL-1P... DPL-1V... DPL-1E...
Operating Instructions for Low Volume Rotating Vane Flow Meter Model: DPL-1P... DPL-1V... DPL-1E... 1. Contents 1. Contents... 2 2. Note... 3 3. Instrument Inspection... 3 4. Regulation Use... 3 5. Operating
More informationSM-10 SM-20-A. Sound Level Meters. Users Manual. For detailed specifications and ordering info go to
SM-10 SM-20-A Sound Level Meters Users Manual For detailed specifications and ordering info go to www.testequipmentdepot.com SM-10 / SM-20-A Sound Level Meters English Users Manual SM10_Rev002 2009 Amprobe
More informationTrigger high-speed, retro-reflective sensors for bottles. Dimensioned drawing
Trigger high-speed, retro-reflective sensors for bottles Dimensioned drawing en 01-2013/11 50121192 10-30 V DC 0 3.6m 5 khz We reserve the right to make changes DS_PRK18BFX_en_50121192.fm Trigger high-speed,
More informationIRB-MON O P E R A T I N G I N S T R U C T I O N S UNIVERSAL SAFETY PHOTOEYE U L M O N I T O R E D DEVICE
O P E R A T I N G I N S T R U C T I O N S IRB-MON UNIVERSAL SAFETY PHOTOEYE U L 3 2 5-2 0 1 6 M O N I T O R E D DEVICE 4564 Johnston Parkway, Cleveland, Ohio 44128 P. 800 426 9912 F. 216 518 9884 Sales
More informationElectro Magnetic Compatibility (EMC)
Electro Magnetic Compatibility (EMC) This equipment complies with the European rules for EMC according to EN5501, EN5500 and EN5008-1. The equipment conforms to the EMC directive and low-voltage directive.
More informationOPERATING INSTRUCTIONS
Electronic Rotational Speed Monitoring Device Type EDO Device Identification No.: 93.045 508.001 /.005 /.007 /.012 OPERATING INSTRUCTIONS 2 CE-Sign an Conformity The device meets the requirements of the
More informationActivity meter. Operating Instructions. AM 1400 adevital Activity. with Bluetooth and data management in linked app
Activity meter with Bluetooth and data management in linked app Operating Instructions AM 1400 adevital Activity Subject to technical changes as a result of product improvements. Operating Manual_AM1400_EN_131214_REV001
More informationSCHOTT FLM 4 Fiber Lighting Modul. Operating Instructions
SCHOTT FLM 4 Fiber Lighting Modul Operating Instructions Contents 1. Important information 3 2. Scope of Delivery 3 3. Intended use 3 4. Safety information 4 5. Operation 5 5.1. LED Optics Module 5 5.2.
More informationAX3000 Platine Terminal Ethernet TCP/IP
AX3000 Platine Terminal Ethernet TCP/IP Model 80WMS Installation Guide January 2012 - Ref: I80ME0922-2 Model AX3000/M80M Type EA The reproduction of this material, in part or whole, is strictly prohibited.
More informationOPT2041. Fiber Optic Cable Sensor. Operating Instructions. Available as PDF only Status:
OPT2041 Fiber Optic Cable Sensor Operating Instructions Available as PDF only Status: 18.06.2018 www.wenglor.com Index 1. Proper Use 3 2. Safety Precautions 3 3. General Information Regarding the Device
More informationCube LAN Gateway. Operating manual BC-LGW-O-TW
Cube LAN Gateway Operating manual BC-LGW-O-TW Package contents Package contents Quantity Item 1x MAX! Cube LAN Gateway 1x 1x 1x 1x 1x 3x Plug-in USB power supply USB cable Network cable Mounting accessories
More informationDiffuse reflection light scanner with background suppression. Dimensioned drawing
Specifications and description HRTR 55 Ex Diffuse reflection light scanner with background suppression Dimensioned drawing en 01-2011/05 50113748 1 khz 5 400mm 200mm with black-white error < 10% 10-30
More informationMobilePro Users Guide Page 1 of 35. MobilePro HPC. User's Guide. Notices Proprietary Notice and Liability Disclaimer Table of Contents
MobilePro Users Guide Page 1 of 35 MobilePro HPC User's Guide Notices Proprietary Notice and Liability Disclaimer Table of Contents Notices This device complies with Part 15 of the FCC Rules. Operation
More informationSee instructions to download and install the latest version of LinkBoxLON and the user's manual at
Safety Instructions WARNING Follow carefully this safety and installation instructions. Improper work may lead to serious harmful for your health and also may damage seriously the IntesisBox and/or any
More information2 Mesa Ethernet Dock User s Manual
owner s manual Mesa Ethernet Dock The Mesa Ethernet Dock is an optional accessory that provides an ethernet port for networking, power input jack, USB client port, and a mounting station for the Mesa Rugged
More informationOperating Instructions for Low Volume Rotating Vane Flow Meter. Model: DPL-1P... DPL-1V... DPL-1E...
Operating Instructions for Low Volume Rotating Vane Flow Meter Model: DPL-1P... DPL-1V... DPL-1E... 1. Contents 1. Contents... 2 2. Note... 3 3. Instrument Inspection... 3 4. Regulation Use... 3 5. Operating
More informationBW-108. Building Wash BW-108. User Guide. Advanced LED Technology
Building Wash User Guide Advanced LED Technology TABLE OF CONTENTS 1. Safety Instruction 2. Technical Specification 3. Change Beam Angle 4. Main Function 5. How To Control The Unit 6. Troubleshooting 7.
More informationIRB-MON UNIVERSAL SAFETY PHOTOEYE OPERATING UL MONITORED DEVICE
IRB-MON UNIVERSAL SAFETY PHOTOEYE OPERATING UL325-2016 MONITORED DEVICE 4564 Johnston Parkway, Cleveland, Ohio 44128 P. 800 426 9912 F. 216 518 9884 Sales Inquiries: salessupport@emxinc.com Technical Support:
More informationLA 90L / LA 180L. Operating instructions
L 90L / L 80L en Operating instructions L 80L 7 3a 5 6 4 3b 8 d b c b a a C L 80 L L 90 L D D >,8m > ft 90 Y Y m 3 3 ft E E E3 F Y D ± 5 D X D3 G,8m ft G G3 S > 5 m > 6 3 ft G4 G5 3 3 en Operating instructions
More informationOperating instructions. Speed monitor D / / 2014
Operating instructions Speed monitor D200 80005257 / 00 05 / 2014 Contents 1 Preliminary note...4 1.1 Symbols used...4 1.2 Warning signs used...4 2 Safety instructions...5 2.1 General...5 2.2 Target group...5
More informationS SENECA. Installation Manual Z-TWS4. Z-PC Line. Web Multifunction Controller Straton / Linux
S SENECA Z-PC Line EN Installation Manual Contents: - General specifications - Technical features - Modbus and CANopen connections - Installation rules - Electrical connections - LEDs signallings - Default
More informationUSER MANUAL Mobeye CM-Guard CM2000
USER MANUAL Mobeye CM-Guard CM2000 SW version 3.n Attention! Very important This user manual contains important guidelines for the installation and usage of the Mobeye device as described in this manual.
More informationUSER MANUAL VIBRATION CONTROL RMA-POWER-BOX 107/230
USER MANUAL VIBRATION CONTROL Version 2.2 1 IMPORTANT NOTES Electrical danger within the meaning of this documentation or the warning labels on the product itself respectively means that death, serious
More informationS40 SERIES INSTRUCTION MANUAL
S0 SERIES The yellow LED indicates the output status. The green LED ON indicates that the received signal has a safety margin compared to the output switching value. See the paragraph for setup procedure
More informationHMEC Instructions for use
HMEC 46-1 Instructions for use Safety instructions Please read this instruction manual carefully and completely before using the headset. Make this instruction manual easily accessible to all users at
More informationOperating Instructions. TCM Timer Counter Module Typ 686
PLUGSYS TCM Timer Counter Module Type 686 Page 1 Operating Instructions for the PLUGSYS module TCM Timer Counter Module Typ 686 (Version 1.1 Printed: July 9, 2012 / from Ser. No. 91001) PLUGSYS TCM Timer
More information*520886* IntelliTouch Pool & Spa Control System MobileTouch Wireless Controller. User s and Installation Guide. P/N Rev A
pool/spa control system IntelliTouch Pool & Spa Control System MobileTouch Wireless Controller User s and Installation Guide P/N 520886 - Rev A *520886* i MobileTouch Wireless Controller kit contents The
More informationManual Control Unit GFC 32
Manual Control Unit 1400004_EN/05.2017 Index 1. Main features 3 2. Technical features 3 3. Installation guidelines 4 4. Preliminary checks 5 5. Electrical connections 5 6. Settings 6 7. Remote control
More informationAssembly and Operating Instructions. M2 module for BDC-i440 control units
BDC-i440 M2 en Assembly and Operating Instructions M2 module for BDC-i440 control units Important information for: Fitters / Electricians / Users Please forward accordingly! These instructions must be
More informationSPOTTER the multipurpose sensor
SPOTTER the multipurpose sensor OVERVIEW Part of the Quirky + GE collection of smart products, Spotter is a multipurpose sensor that keeps you updated on what s going on at home from anywhere. Monitor
More informationHD 46 HME 46. Instructions for use
HD 46 HME 46 Instructions for use Safety instructions Please read these instructions carefully and completely before using the headset. Make these instructions easily accessible to all users at all times.
More informationE3S-A. Built-in Amplifier Photoelectric Sensor (Medium Size) Ordering Information. Built-in Amplifier Photoelectric Sensors. Horizontal. 7 m.
Built-in Amplifier (Medium Size) ES-A Be sure to read Safety Precautions on page 0. Ordering Information Built-in Amplifier s Red light Infrared light Sensing method Appearance Connection method Sensing
More information1. CP430, CP470, CP474, CP770 and CP774
1. CP430, CP470, CP474, CP770 and CP774 1.1 Order data CPUs CP430, CP470, CP474, CP770 and CP774 CP430, CP470, CP770 CP474, CP774 Model number 7CP430.60-1 7CP470.60-2 7CP474.60-2 7CP770.60-1 7CP774.60-1
More informationCamtraptions PIR Motion Sensor v3 Manual. Firmware Version 2.2
Camtraptions PIR Motion Sensor v3 Manual Firmware Version 2.2 Index Index... 2 What is a PIR Motion Sensor?... 3 What is new in Version 3?... 3 Primary Controls... 4 Dials... 4 Switches... 4 On-off Switch...
More informationInstallation- and Operating instructions for CU Ethernet Controller with USB Input. Version: 1.4 Date:
Installation- and Operating instructions for CU8880-0010 Ethernet Controller with USB Input Version: 1.4 Date: 2018-04-12 Table of contents Table of contents 1. 2. 3. 4. 5. General instructions 2 Notes
More informationBLUETOOTH SPEAKER GSB 600 NFC
EN BLUETOOTH SPEAKER GSB 600 NFC CONTENTS ----------------------------------------------------------------------------------------------------------------------------------- 3 SET-UP AND SAFETY 3 RF Exposure
More information