1 99 Washington Street Melrose, MA Phone Toll Free Visit us at SBS-S SERIES DC LOAD BANK USER MANUAL Models Covered SBS-4830S SBS-1110S SBS-2206S SBS-1230S SBS-2415S
2 Contents OPERATING INSTRUCTIONS 1. Environments Requirement 2. Main Tester Description 3. Main Tester Connection 4. Start Up and Input Operation 5. Parameter setting 6. Starting Discharge Test 7. Stopping Discharge Test 8. Test result 9. Calibration interface Technical Data Display Input Test Type Protection Power Supply DC Cables LCD (128 x 64 pixels) During discharge: real time voltage / current / test time / Ah User can set: end system voltage / test time / Capacity discharged (Ah) Unit controls the current so it stays where it is set throughout the test Over heat / Over load / Over voltage protection with audible alarm and screen warning 24/48 Vdc modules use DC power supply (from tested battery) 125 and 250 Vdc models use AC power supply (120 Vac 60 Hz) Included - 9 ft long Specifications Part No. DC Voltage Range DC Current Range (Amps) Dimensions L x W x H (in.) Weight (lbs.) SBS-4830S Vdc 0-150A 26 x 9 x for Vdc 0-300A SBS-1110S Vdc 0-100A 25 x 9 x SBS-1230S Vdc 0-300A 36 x 9 x SBS-2206S Vdc 0-60A 26 x 9 x SBS-2415S Vdc 0-150A 36 x 9 x
3 OPERATING INSTRUCTIONS 1. Environments Requirement Should be NO CORROSIVE,NO EXPLOSIVE,NO ELECTRICAL BREAKDOWN AIR OR CONDUCTIVE DUST. 2. Main Tester Description LCD screen Cooling fans Control Buttons External control socket External current measurement socket Power switch (For 4815S/4830S) Power switch & AC power input (For other types) Load cable sockets SBS-S series 3. Main Tester Connections 3.1 power cable connection Connect SBS-S with the tested battery group (or rectifier, DC generator) 3.2 Power Supply connection
4 3.2.1 SBS-4815S, SBS-4830S are powered from the DC load, so there is no power supply connector for these models For other SBS-S series types, connect SBS-S with AC 120V 60Hz power source by power supply cable. Power supply wire 120 V 60Hz Power Source (Optional: 220V 50Hz) Power switch SBS-S series 4. Start Up And Input Operation 4.1 After the load connections are made, turn on the power switch to start up SBS-S series Load Bank. 4.2 All settings of the SBS-S are input through the 6 control buttons beneath the LCD screen. 4.3 On the welcome screen, you can see our company name, the model number, and tester name. Press any key to enter the main menu, if 10 seconds elapse without a key press, the system will switch to the main menu automatically. 5. Parameter setting Welcome interface Main menu
5 5.1 In main menu, please use & to choose Setting, press into setting interface. There are 4 parameters need to be set before testing. 5.2 Set the discharge current by &, and press go to next parameter. 5.3 Set the capacity need to be discharged by &, and press go to next parameter. (If the capacity discharged is over the setting value, SBS-S will terminate the test automatically.) 5.4 Set discharge time by &, and press go to next parameter.(if the discharge time is over the setting value, SBS-S will terminate the test automatically.) 5.5 Set voltage stop threshold by &, and press go to next parameter.(if the voltage go below the setting value, SBS-S will terminate the test automatically.) 5.6 please use & to locate the item you need for changing the setting. And press to confirm the setting and LCD will show setting saved! message. Press back to main menu.
6 6. Starting discharge test 6.1 In the main menu, use & to choose Discharge, press into it. 6.2 SBS-S will display all of the parameter settings before discharge, use & to verify all settings again and press to start the discharge. 6.3 The discharge interface LCD will display: a) Discharge status: Proceeding or Stopped b) Voltage c) Discharge current (Amps) d) Capacity discharged (Cumulative AH) e) Discharge time 6.4 Press to manually stop test, and press to manually re-start the test. 6.5 During the discharge test, press & back to parameter settings, you can modify the setting values by &, and press to activate new setting and continue discharge. 7. Stopping discharge test 7.1 Manual stop: press during discharging. 7.2 Stop threshold reached: Condition Discharged capacity has reached the preset value in settings. Discharge Time setting has been reached Voltage has reached the LOW DC voltage setting. LCD message
7 7.3 Test termination by fault/error Condition Discharge current exceeds the limits of machine for the voltage range. The unit has terminated the discharge due to reaching the Thermal limit. Polarity of the test cables is reversed. LCD message 8. Discharge Test Results Screen The SBS-S will save the last test result in Test result interface. It can show: a) Test end voltage b) Test time c) Capacity discharged d) Stop reason Stop reason 9. Calibration interface SBS-S supports calibration by the user, with high resolution instrument, user can finish calibrate in calibration interface: 1) Voltage 2) Discharge current 3) External current from current clamp press & to select the calibration item and change the setting value by &, and press to save calibration.
8 WARNINGS a) Please read the entire manual prior to using the test equipment b) The tester features a number of built in safety features to allow for unmonitored operation, however, it is at the users discretion to operate the unit unmanned. c) In the event of a fault or warning during the test, an audible warning will sound and a visual warning will be displayed. Please turn off the AC power source to avoid a further damage. Parallel Operation The SBS S Series load banks can be operated in parallel with the SBS-8400 or another S Series load bank of the same voltage range. The External Current Clamp (SBS Part # A) must be used to share load information between the two load banks. Each load bank must be set up to control its own portion of the load and must operate within its operational limits per the specifications. The master load bank where the current clamp is plugged into will display the total load current of the system when the discharge test is running. After-Sale Service Storage Battery Systems, LLC: provides technical consulting and repair servicing for all of our battery testing equipment. If you have any technical questions or problems, please contact us:
SBS-S SERIES DC LOAD BANK USER MANUAL Rev
SBS-S SERIES DC LOAD BANK USER MANUAL Rev. 2.0 12-14 Test Equipment Depot - 800.517.8431-99 Washington Street Melrose, MA 02176 TestEquipmentDepot.com Contents OPERATING INSTRUCTIONS 1. Environment Requirement
More informationSBS-8400 BATTERY CAPACITY TESTER USER MANUAL Rev
SBS-8400 BATTERY CAPACITY TESTER USER MANUAL Rev. 2.1 12-14 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com Contents 1. Introduction
More informationSBS-4815CT BATTERY CAPACITY TESTER USER MANUAL
SBS-4815CT BATTERY CAPACITY TESTER USER MANUAL STORAGE BATTERY SYSTEMS, LLC N56W16665 Ridgewood Dr., Menomonee Falls WI 53051 Phone: (800) 554-2243 Fax: (262) 703-3073 Website: www.sbsbattery.com Contents
More informationSBS-8400 USER MANUAL BATTERY DISCHARGE & CAPACITY TESTER
SBS-8400 USER MANUAL BATTERY DISCHARGE & CAPACITY TESTER Storage Battery Systems N56 W16665 Ridgewood Dr. Menomonee Falls, WI 53051 USA Tel: 800-554-2243 www.sbsbattery.com Contents 1. Introduction 1.1
More informationMicro-Ohmmeter. Digital 200A. Model Measure low resistance with high accuracy
Digital 200A Micro-Ohmmeter Model 6290 Measure low resistance with high accuracy Accurately measures low contact resistances with test currents up to 200A Measures resistances up to 20mΩ Low resolution
More informationMini Digital Multimeter
User's Guide Mini Digital Multimeter Model MN15 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com Back to the Extech MN15/MN16 Series
More informationDC / AC True RMS Watt Clamp DMM
99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com Back to the Extech 380940 Product Page DC / AC True RMS Watt Clamp DMM 10W or 100mA
More informationGUT-6000B Digital IC Tester USER MANUAL. 99 Washington Street Melrose, MA Phone Toll Free
GUT-6000B Digital IC Tester USER MANUAL 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com INTRODUCTION...3 FEATURES...4 SPECIFICATIONS...5
More informationSBS-200CT BATTERY DISCHARGE CYCLER USER MANUAL
SBS-200CT BATTERY DISCHARGE CYCLER USER MANUAL Contents OPERATING INSTRUCTIONS 1. Environments Requirement 2. Main Tester Description 3. Wireless Module Description 4. Main Machine Connection 5. Wireless
More informationIDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODELS:
IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODELS: 61-773 61-775 The Service Information provides the following information: Precautions and safety information Specifications Performance test procedure Calibration
More informationPen Vibration Meter. User's Guide. Model VB Washington Street Melrose, MA Phone Toll Free
User's Guide 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com Pen Vibration Meter Model VB400 Introduction Congratulations on your
More informationModel HM-535 Power Supply Installation and Service Instructions
Model HM-535 Power Supply Installation and Service Instructions 430-535 0104 2004 Heritage MedCall, Inc SENTRY INSTALLATION & SERVICE INSTRUCTIONS POWER SUPPLY UNIT Model HM-535 IMPORTANT SAFETY INSTRUCTIONS
More information99 Washington Street Melrose, MA Phone Toll Free Visit us at INSTRUCTION MANUAL
99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com INSTRUCTION MANUAL Test Equipment Depot - 800.517.8431-99 Washington Street Melrose,
More information12V POWER SUPPLY / BATTERY CHARGER
Power Supply Power supplies are designed and manufactured by EDS to perform efficiently in a wide range of applications such as CCTV, Intrusion detection, Access control and Fire alarm systems. 12V / BATTERY
More informationMAINTENANCE MANUAL. EDACS REDUNDANT POWER SUPPLY SYSTEM 350A1441P1 and P2 POWER MODULE CHASSIS 350A1441P3, P4, AND P5 POWER MODULES TABLE OF CONTENTS
MAINTENANCE MANUAL EDACS REDUNDANT POWER SUPPLY SYSTEM 350A1441P1 and P2 POWER MODULE CHASSIS 350A1441P3, P4, AND P5 POWER MODULES TABLE OF CONTENTS SPECIFICATIONS*... 2 INTRODUCTION... 3 DESCRIPTION...
More informationUser s Guide. 600A True RMS AC/DC Clamp Meter. Model 38389
User s Guide 600A True RMS AC/DC Clamp Meter Model 38389 Safety International Safety Symbols This symbol, adjacent to another symbol or terminal, indicates the user must refer to the manual for further
More informationRangerBOSS Network Ready Constant Monitor Model CM2800
RangerBOSS Network Ready Constant Monitor Model CM2800 Instruction Manual Contents 1 Description CM2800 1 Features 1 2 Installation Installation Instructions 2 Installation Diagram 3 3 Operation Wrist
More informationInstallation and Operation Back-UPS BR1000G-IN / BR1500G-IN
Installation and Operation Back-UPS BR1000G-IN / BR1500G-IN Important Safety Information Read the instructions carefully to become familiar with the equipment before trying to install, operate, service
More informationTHOR Battery Backed DC Power Supply Reference Manual
THOR Battery Backed DC Power Supply Reference Manual Revision A Firmware Compatibility: V1.03 P/N 60098001 Revised: 4/26/2012 INDUSTRIAL CONTROL LINKS, INC. 12840 Earhart Avenue Auburn, CA 95602 Tel: (800)
More informationInstruction Manual. 2in1 LAN Tester & Multimeter. Model: 57314
Instruction Manual 2in1 LAN Tester & Multimeter Model: 57314 1 Contents Introduction... Features... Safety Precautions.. Meter Description... Electrical Specification... Operation.. AutoRanging Multimeter.
More information2 in 1 LAN Tester and Multimeter Model:
2 in 1 LAN Tester and Multimeter Model: 72-8495 1 IMPORTANT SAFETY INFORMATION Please read these instructions carefully before use and retain for future reference. This instrument is designed and manufactured
More informationIDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL:
99 Washington Street Melrose, MA 02176 Fax 781-665-0780 TestEquipmentDepot.com IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL: 61-609 The Service Information provides the following information: Precautions
More informationRT4F-110V/25A RECTIFIER
The RT4F-110V/25A is a hot-pluggable switched mode rectifier (SMR) module designed to provide up to 25A of output current into a 110V nominal system. Examples of such systems are 60 cells lead acid (136V
More informationOPR Power Series AC to DC POWER SUPPLY SERIES WITH REMOTE MANAGEMENT AND ALARM SYSTEMS. Model Nos. OPR065-48S / OPR065-48R. Manual
OPR Power Series AC to DC POWER SUPPLY SERIES WITH REMOTE MANAGEMENT AND ALARM SYSTEMS Model Nos. OPR065-48S / OPR065-48R Manual Revision F July 2009 Optimal Power Supplies LLC www.optimal-power.com i
More informationLaboratory Switch Mode Power Supply Series. Instruction Manual
Laboratory Switch Mode Power Supply Series Instruction Manual Model 72-8340 1.0 ~ 60VDC 0 ~ 1.6A 72-8345 1.0 ~ 36VDC 0 ~ 3A 72-8350 1.0 ~ 20VDC 0 ~ 5A Copyright 2008, all rights reserved Tenma Test Equipment
More informationRT4F-120V/20A-WAC RECTIFIER
The RT4F-120V/20A-WAC is a switched mode rectifier/charger module designed to provide up to 20A of output current into a 120V nominal system. This charger has been designed for use in conjunction with
More informationModel A Mini AC/DC Clamp Meter. User's Guide
Model 380950 80A Mini AC/DC Clamp Meter User's Guide Introduction Congratulations on your purchase of the Extech 80A Mini AC/DC Clamp Meter. The Model 380950 measures AC/DC Current, AC/DC Voltage, Resistance,
More informationIRM-5000P. insulation resistance meter. Vanguard Instruments Company, Inc.
IRM-5000P insulation resistance meter Vanguard Instruments Company, Inc. www.vanguard-instruments.com IRM-5000P insulation resistance meter The IRM-5000P is a microprocessor-based, high-voltage, insulation-test
More informationMTP INSTRUCTION MANUAL
DT-118B MTP INSTRUCTION MANUAL Pocket Autoranging Digital Multimeter 3 in 1 Model MTP-1025 Auto Ran ging DMM Hz% A OFF V AU TO PO WER OFF MTP Instruments Table of Contents Introduction Page 1 Features
More informationADDITIONAL INSTALLATION TIPS CAN BE FOUND AT:
User s Manual for AC Mobile Power 90/140/150 Watt Inverter ADDITIONAL INSTALLATION TIPS CAN BE FOUND AT: www.cyberpowersystems.com/faqs.htm Introduction Thank you for purchasing the CyberPower 90/140/150
More informationRT4F-48V/50A-WAC RECTIFIER
The RT4F-48V/50A-WAC is a switched mode rectifier (SMR) module designed to provide up to 58A of output current into a 48V nominal system, over a wide range of AC input voltage. This rectifier has been
More informationCM-220 True RMS AC CLAMP METER INSTRUCTION MANUAL
CM-220 True RMS AC CLAMP METER INSTRUCTION MANUAL Safety International Safety Symbols This symbol, adjacent to another symbol or terminal, indicates the user must refer to the manual for further information.
More informationFlomatic Smart Card TM Model FDHC-100 (Digital High-Resolution Controller) Configuration and Operation Manual
The Flomatic FDHC-100 is a high performance Digital positioner intended to control AC actuators, providing 450 points of resolution with quarter turn actuators ranging from 2 sec to 120 sec and rated for
More information2 in1 LAN Tester & Multimeter. Model: PCE-LT 1
www.pce-industrial-needs.com Tursdale Technical Services Ltd Unit N12B Tursdale Business Park Co. Durham DH6 5PG United Kingdom Phone: +44 ( 0 ) 191 377 3398 Fax: +44 ( 0 ) 191 377 3357 info@tursdaletechnicalservices.co.uk
More informationUser's Guide. MiniTec TM Series Model MN25 MultiMeter
User's Guide MiniTec TM Series Model MN25 MultiMeter Warranty EXTECH INSTRUMENTS CORPORATION warrants this instrument to be free of defects in parts and workmanship for one year from date of shipment (a
More informationTRIPLETT WireMaster Mapper
TRIPLETT WireMaster Mapper 8-Way Wire & Cable Mapping Kit Instruction Manual 84-876 3/09 Test Equipment Depot - 800.517.8431 99 Washington Street, Melrose, MA 02176 TestEquipmentDepot.com TABLE OF CONTENTS
More informationHCS-3600 / 3602 / 3604 Laboratory Grade & High RFI Immunity Switching Mode Power Supply with Rotary Encoder Control
HCS-3600 / 3602 / 3604 Laboratory Grade & High RFI Immunity Switching Mode Power Supply with Rotary Encoder Control 1. INTRODUCTION User Manual This family of efficient, upgraded SMPS with small form factor,
More informationMICRO BURN IN PRODUCTS LISTED IN MODEL NUMBER ORDER FOLLOWED BY A BRIEF DESCRIPTION
MICRO BURN IN PRODUCTS LISTED IN MODEL NUMBER ORDER FOLLOWED BY A BRIEF DESCRIPTION MODEL 102P 102R DESCRIPTION Floor Stand (Plane) Floor Stand (Modified) HTRB Burn-In System (diode) Component Burn-In
More informationUser's Guide. Model W 3-in-1 Switching DC Power Supply
User's Guide Model 382260 80W 3-in-1 Switching DC Power Supply Introduction Congratulations on your purchase of the Extech 80W 3-in-1 Switching DC Power Supply. The Model 382260 has three output ranges
More informationRT12-240V/2.4kW Rectifier Specification
The RT12-240V/2.4kW is a switched mode rectifier (SMR) module that delivers up to 2.4kW of output power (and up to 11A output current) into a 240V nominal DC system. The RT12 suits AC supply voltages between
More informationModular Power System 1200 W per mainframe GPIB
View at www.testequipmentdepot.com High Performance DC Power Supplies 1200 W per mainframe GPIB Modular system permits up to 8 outputs of 150 W per output in 4 U of rack space Reconfigure fast with easily
More informationDigital Clamp Meter User Manual
Compact AC, AC/DC Digital Clamp Meter User Manual Please read this manual before switching the unit on. Important safety information inside. Contents 1.Safety... 3 2.Safety Notes... 3 3.Warnings... 3 4.Cautions...
More informationIDEAL INDUSTRIES INC. TECHNICAL MANUAL MODEL:
IDEAL INDUSTRIES INC. TECHNICAL MANUAL MODEL: 61-795 The Service Information provides the following: Precautions and safety information Specifications Performance test procedure Calibration and calibration
More informationCurrent Loop Indicator PanelPilot Compatible Smart Graphics Display
PanelPilot Compatible Smart Graphics Display ORDERING INFORMATION Standard Display SGD 24-M42 (Panel meter, fixing kit, quick start guide) USB Cable CABLE USB A-MF (Type A to mini-b) USB Power Supply UK
More informationMini Digital Multimeter
User Manual Mini Digital Multimeter Model MN15A Additional User Manual Translations available at www.extech.com Introduction Congratulations on your purchase of the Extech MN15A MultiMeter. The MN15A offers
More informationBack-UPS RS 550 Installation & Operation
Back-UPS RS 550 Installation & Operation Inventory Safety Do not install the UPS in direct sunlight, in excessive heat, humidity, or in contact with fluids. bu001a Do not connect a laser printer or hair
More informationTTC Series Torque Tool Tester Operation Manual
TTC Series Torque Tool Tester Operation Manual Operators should wear protection such as a mask and gloves in case pieces or components break away from the unit under test. Whether the unit is ON or OFF,
More informationTesting Instruments Manufactured by
Circuit Breaker Dynamic Contact Resistance Meter HISAC Ultima Circuit Breaker Dynamic Test Set with up to Six Channel Dynamic Contact Resistance Meter 24 Binary Channels (4 Main + 4 PIR per Pole, 3 Poles
More information80W (16V/5A) Power Supply with USB Output. User Manual
Test Equipment Depot - 800.517.8431-99 Washington Street Melrose, MA 02176 TestEquipmentDepot.com 1325 80W (16V/5A) Power Supply with USB Output User Manual 1325 Volt. C.V. Amp. C.C. V OUTPUT ON/OFF A
More informationUser Manual. 400Amp AC Clamp Meter + NCV. Model MA430. Additional User Manual Translations available at
User Manual 400Amp AC Clamp Meter + NCV Model MA430 Additional User Manual Translations available at www.extech.com Introduction Congratulations on your purchase of this Extech MA430 Clamp Meter. This
More informationModel INSTRUCTION MANUAL DIGITAL MULTIMETER
Model 57040 INSTRUCTION MANUAL DIGITAL MULTIMETER SAFETY INFORMATION This multimeter has been designed according to IEC 1010 concerning electronic measuring instruments with an overvoltage category (CAT
More informationOperating Instructions
Represented in Australia by: EMONA Instruments Pty Ltd 78 Parramatta Rd Camperdown NSW 2050 Tel: (02) 9519 3933 www.emona.com.au, www.protag.com.au testinst@emona.com.au Part Number 372A580 Revision 4
More informationMCCB-250 MOLDED-CASE CIRCUIT BREAKER TESTER
MCCB-250 MOLDED-CASE CIRCUIT BREAKER TESTER USER S MANUAL Vanguard Instruments Company, Inc. 1520 S. Hellman Ave. Ontario, California 91761, USA TEL: (909) 923-9390 FAX: (909) 923-9391 January 2015 Revision
More informationPostfach 2327, Offenburg * Helmholtzstr. 13, Offenburg. Technical Data. Model protecto ER
On-line UPS-system according to DIN EN 62040-3 (VFI-SS-111) with sinus soidal output voltage in each operation mode, RS232 interface and Shutdown-Software for Windows NT/2000/XP/2003/Vista, Novell and
More information! Ranges from -45º to 650ºC. ! Rapid heating, cooling and settling. ! Switch test, ramp, step and preset functions
DBC SERIES DBC 150/650 Series Dry Block Temperature Calibrators 99 Washington Street Melrose, MA 02176 Fax 781-665-0780 TestEquipmentDepot.com! s from -45º to 650ºC! Rapid heating, cooling and settling!
More informationLVDT Test Device. Product Manual (Revision B) Original Instructions. Testing and Calibration of LVDT Feedback Devices on PG Governors
Product Manual 55036 (Revision B) Original Instructions Testing and Calibration of LVDT Feedback Devices on PG Governors Operation Manual DEFINITIONS This is the safety alert symbol. It is used to alert
More informationUser's Guide. 800 Amp Clamp Meters. EX710 AC Clamp meter EX720 True RMS AC Clamp meter EX730 AC/DC True RMS Clamp meter
User's Guide 800 Amp Clamp Meters EX710 AC Clamp meter EX720 True RMS AC Clamp meter EX730 AC/DC True RMS Clamp meter Introduction Congratulations on your purchase of the EX710, EX720, or EX730 Clamp DMM.
More informationDM-918 OPERATIONS MANUAL AUTORANGING MULTIMETER
DM-918 OPERATIONS MANUAL AUTORANGING MULTIMETER SAFETY INFORMATION The following safety information must be observed to ensure maximum personal safety during the operation of this meter: This meter is
More informationUser s Guide. 600A AC Clamp Meter. Model 38387
User s Guide 600A AC Clamp Meter Model 38387 Safety International Safety Symbols This symbol, adjacent to another symbol or terminal, indicates the user must refer to the manual for further information.
More informationR5050. Model. Instruction Manual. TRMS AC/DC Clamp Meter. reedinstruments. www. com
Model R5050 TRMS AC/DC Clamp Meter Instruction Manual reedinstruments com Table of Contents Safety... 3 Features... 4 Specifications...4-6 Instrument Description...7-8 Measurement Procedures...9-12 Battery
More informationEARTH RESISTANCE & RESISTIVITY TESTER
99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com BST-ET103 EARTH RESISTANCE & RESISTIVITY TESTER INSTRUCTION MANUAL INDEX 1. INTRODUCTION...
More informationVBT-75 S2 VACUUM BOTTLE TESTER
VBT-75 S2 VACUUM BOTTLE TESTER USER S MANUAL Vanguard Instruments Company, Inc. 1520 S. Hellman Ave. Ontario, California 91761, USA TEL: (909) 923-9390 FAX: (909) 923-9391 July 7, 2017 Revision 1 SAFETY
More informationME3 Mobile Cabinet Three Phase Frequency Converter, Operation and Maintenence.
29-30 Brunel Road, Churchfields Industrial Estate, St. Leonards-on-Sea East Sussex. TN38 9RT. United Kingdom Sales & Service : 01424 853 013 All Other Departments : 01424 853 464 Fax : 01424 852 268 magnuspower.sales@akersolutions.com
More informationNTP-5521/5531/5561 SWITCHING MODE POWER SUPPLY
NTP-5521/5531/5561 SWITCHING MODE POWER SUPPLY USER MANUAL Keep this manual in a safe place for quick reference at all times. This manual contains important safety and operation instructions for correct
More informationThe PCI Series. Precise power control for complex SCR applications. Phase Angle Fired SCR Power Controls AMPS VAC
The PCI Series Phase Angle Fired SCR Power Controls 25-1200 AMPS 120-600 VAC Precise power control for complex SCR applications. ROBICON 1996 Distributed Worldwide by www.mcgoff-bethune.com Applications
More informationS-14 S-14. Compact Digital Multimeter. Compact Digital Multimeter
S-14 Compact Digital Multimeter S-14 Compact Digital Multimeter SAFETY INFORMATION The following safety information must be observed to insure maximum personal safety during the operation at this meter
More informationSentinel AC & DC Current Logger Models SDL A401 & SDL A402
Sentinel AC & DC Current Logger Models SDL A401 & SDL A402 Model SDL A402 The Sentinel Current Logger Models SDL A401 and SDL A402 are designed for use with AEMC detachable current probes or AmpFlex sensors
More informationOPERATING INSTRUCTION
OPERATING INSTRUCTION AUTORANGING MULTIMETER MAX Ω F C 10A MAX every 15 min. COM V SAFETY INFORMATION The following safety information must be observed to insure maximum personal safety during the operation
More informationPlease comply with all warnings and operating. instructions in this manual strictly. Save this. manual properly and read carefully the following
Please comply with all warnings and operating instructions in this manual strictly. Save this manual properly and read carefully the following instructions before installing the unit. Do not operate this
More information2200 Series. Quick Start Guide SAFETY CHECKLIST. Safety Made Simple
Safety Made Simple SAFETY CHECKLIST KEEP unqualified/unauthorized personnel away from the test area ARRANGE test stations in a safe and orderly manner NEVER touch products or connections during a test
More informationRT4B-110V/12A RECTIFIER
The RT4B-110V/12A is a switched mode rectifier (SMR) module designed to provide up to 12A of output current into a 110V nominal system. It can be used with or without a cooling fan. With a fan it runs
More informationAirTest Model CN9000 Series Sensor Controller
AirTest Model CN9000 Series Sensor Controller AirTest Model CN9000 Series Sensor Controller THEORY OF OPERATION A basic CN9000 configuration consists of Input/Process/Display combination modules, a 3 relay
More informationPowerMust Office Uninterruptible Power System
USER MANUAL E PowerMust Office Uninterruptible Power System 614-05737-05 28-2PRO000001 IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS This manual contains important instructions for Models PowerMust
More information4-step Chiller and Heat Pump Controller
4-step Chiller and Heat Pump Controller Technical Data Sheet GENERAL DESCRIPTION MODELS CODE MODEL DESCRIPTION MW324000 ECH 420 HEAT PUMP WITH 4 STEPS/ 2 CIRCUITS + MODBUS MW324005 ECH 420/V WITH SCREW
More informationProduct Specifications
Product Specifications Models: USC-10001, USC-10002 USC-20001, USC-20002 USC-30001, USC-30002 Guide Specification for UniStar C Series Rack/Universal 1, 2, 3Kva Single-Phase, On-Line Double Conversoin
More informationEATON 5S 850/1200/1600
www.eaton.com EATON 5S 850/1200/1600 Installation and user manual Packaging EATON 5S 1 2 3 5 Caution! l Before installing the Eaton 5S, read the booklet 3 containing the safety instructions to be respected.
More informationFG-7000 Digital Force Gauge Operation Manual
FG-7000 Digital Force Gauge Operation Manual Operators should wear protection such as a mask and gloves in case pieces or components break away from the unit under test. Whether the unit is ON or OFF,
More informationUser's Guide. Digital Multimeter. Model MN42
User's Guide Digital Multimeter Model MN42 Introduction Congratulations on your purchase of the Extech MN42 MultiMeter. The MN42 offers AC/DC Voltage, DC Current, and Resistance testing. Proper use and
More informationVisit us at Back to the Extech Product Page
99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com Back to the Extech 407355 Product Page User's Guide Noise Dosimeter with PC Interface
More informationINSTRUCTION MANUAL HIGH CURRENT DRIVER BOARD STAND ALONE
Instruction Manual High Current Driver Board Stand Alone 1 INSTRUCTION MANUAL HIGH CURRENT DRIVER BOARD STAND ALONE Models: 1 AMP: HCDBSA1_0AMP 1.5 AMP: HCDBSA1_5AMP 2.0 AMP: HCDBSA2_0AMP 2.5 AMP: HCDBSA2_5AMP
More informationP216 Series Condenser Fan Speed Controller
P216 Series Condenser Fan Speed Controller Installation Instructions P216xxx-x Part No. 24-85895-18, Rev. D Issued 27 August 2015 Applications Refer to the QuickLIT website for the most up-to-date version
More informationMini Digital Multimeter
User's Guide Mini Digital Multimeter Model MN15 Introduction Congratulations on your purchase of the Extech MN15 MultiMeter. The MN15 offers AC/DC Voltage, AC/DC Current, Resistance, Diode, and Continuity
More information840CT Battery Discharger &Capacity Tester
840CT Battery Discharger &Capacity Tester Wide voltage range battery discharger: 12V to 280V 5.7 inch LCD touch screen for easy operation and showing various parameters real time Selectable discharge mode:
More informationORYON RING LIGHTS. 14 in. Ring Light and 18 in. Ring Light. Quick Start Guide. What s Included
ORYON RING LIGHTS Quick Start Guide 14 in. Ring Light and 18 in. Ring Light What s Included 1 x RLB40 or RLB48 1 x Power Cable 1 x Phone Mount 1 x 15mm Rail adaptor 1 x Dual Battery Charger 2 X Sony L
More informationHI-POT TESTER User Manual
HI-POT TESTER 7600 User Manual Contents 1. Safety...- 3-1.1 General...- 3 - AC Power Supply...- 4-1.2 Adjustment, Maintenance and Repair...- 5-1.3 Static Electricity...- 5-2. General:...- 6-2.1Packing
More informationUser's Guide. Dual Input RTD Thermometer. Model Washington Street Melrose, MA Fax TestEquipmentDepot.
User's Guide 99 Washington Street Melrose, MA 02176 Fax 781-665-0780 TestEquipmentDepot.com Dual Input RTD Thermometer Model 421504 Specifications General Specifications Display 5-digit LCD with overload/open-input
More informationLine Interactive 1000VA/1400VA/2000VA Uninterruptible Power System
USER MANUAL Line Interactive 1000VA/1400VA/2000VA Uninterruptible Power System 614-06762-00 IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS This manual contains important instructions for Line Interactive
More information99 Washington Street Melrose, MA Phone Toll Free Visit us at
99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com Table of Contents 1. General Safety Requirements... 1 2. Safety Terms and Symbols...
More informationGigabit inline PoE tester and detector
Gigabit inline PoE tester and detector PoE Tester p1 Data compatibility: o 10/100 and gigabit data rates o Data passes without modification thru the tester o An RF transformer separates the power and data
More informationMAJOR VA Power Inverter
MAJOR500-500 VA Power Inverter The Major500 is a highly reliable, telecom quality, DC to AC power inverter. The Major500 features full electronic protection, high efficiency and low output noise. The built-in
More informationSHIMPO INSTRUMENTS. FG-7000T Digital Torque Gauge Operation Manual
FG-7000T Digital Torque Gauge Operation Manual SHIMPO INSTRUMENTS Operators should wear protection such as a mask and gloves in case pieces or components break away from the unit under test. Whether the
More informationUser Guide True RMS Multimeter Extech EX205T
User Guide Extech EX205T True RMS Digital Multimeter Extech EX210T True RMS Digital Multimeter IR True RMS Multimeter Extech EX205T Introduction Thank you for selecting the Extech EX205T True RMS Auto-ranging
More informationSGD 35-M. PanelPilot Compatible Smart Graphics Display ORDERING INFORMATION FEATURES SPECIFICATIONS
PanelPilot Compatible Smart Graphics Display ORDERING INFORMATION Standard Display (Panel meter, fixing kit, quick start guide) 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431
More informationUPS Series. features: uninterruptible power supply. what great systems are built on.
uninterruptible power supply uninterruptible power supply with energy saver design that is optimized to address the needs of A/V systems features: Pure Sine Wave technology with Automatic Voltage Regulation
More informationTraceTek Leak Detection Master Module Installation Instructions TOOLS REQUIRED STORAGE
TTDM-128 TraceTek Leak Detection Master Module Installation Instructions TRACETEK APPROVALS AND CERTIFICATIONS TYPE NM General Signaling Equipment 76LJ GENERAL INFORMATION Please read these instructions
More informationDRP16 Series. User Guide. DVR Surge Protector & UPS. DITEK Corporation One DITEK Center 1720 Starkey Road Largo, FL
DRP16 Series DVR Surge Protector & UPS User Guide INT-100084-001 Rev 7 06/10/08 191004 DITEK Corporation One DITEK Center 1720 Starkey Road Largo, FL 33771 1-800-753-2345 www.ditekcorp.com DITEK CORPORATION
More informationMCCB-500 MOLDED-CASE CIRCUIT BREAKER TESTER
MCCB-500 MOLDED-CASE CIRCUIT BREAKER TESTER USER S MANUAL Vanguard Instruments Company, Inc. 1520 S. Hellman Ave. Ontario, California 91761, USA TEL: (909) 923-9390 FAX: (909) 923-9391 January 2015 Revision
More informationEnergy Logger. User's Guide. Model EM Washington Street Melrose, MA Phone Toll Free
User's Guide 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com Energy Logger Model EM100 Introduction Congratulations on your purchase
More informationInstallation and Operation Back-UPS Pro 900
Us er Documentation Installation and Operation Back-UPS Pro 900 Inventory bu001a User Documentation (2) Safety and General Information Inspect the package contents upon receipt. Notify the carrier and
More informationZenith DS9000 Dispensing System
Page Date: 04/2009 Zenith DS9000 Dispensing System Installation & Operation Manual Page 2 Table of Content Introduction... 3 Control Specification... 4 Wiring Diagram... 5 Wiring Instructions... 6 Field
More information