Use of the application program
|
|
- Adrian Nelson
- 5 years ago
- Views:
Transcription
1 Use of the application program Product family: Product type: Manufacturer: Name: Order no.: Table of contents Communication Interface Siemens IP Gateway KN-BACnet N 143 5WG AB01 1. Functional description... 1 Behavior at bus voltage failure / recovery... 2 Factory default state... 2 Behavior on unloading the application program... 3 Resetting the device to factory default settings Communication objects Functions (, s)... 4 General settings... 4 for the... 6 Switching / Status On/Off (1 bit) bit (Prozentwert) bit (Unsigned integer) bit (Signed integer) bit value (Unsigned integer) bit (Signed integer) bit (Float) bit (Unsigned integer) bit (Signed integer) bit (Float) BACnet Product Description Protocol Implementation Conformance Statement (PICS) BACnet Stack BACnet Functional description The application program 07 B0 CO IP Gateway KN- BACnet can be used for the KN device listed above. This device is briefly described in the next section. The IP Gateway KN/BACnet N 143 is a DIN rail mounted device connecting a KN installation with a system using BACnet communication. The Gateway provides up to 250 communication objects. Via these objects KN functions (group addresses) are transposed to BACnet objects. The communication objects can be configured optionally as: switching/status on/off (1 bit) 8-bit value (percent value) 8-bit value (unsigned integer) 8-bit value (signed integer) 16-bit value (unsigned integer) 16-bit value (signed integer) 16-bit value (float) 32-bit value (unsigned integer) 32-bit value (signed integer) 32-bit value (float) The device is configured entirely with ETS. The configuration of the KN communication objects automatically generates the corresponding BACnet objects. The following BACnet objects are being used: Binary Binary Binary Analog Analog Analog No special knowledge about BACnet is required for the commissioning. The KN objects configured with ETS are automatically translated by the device into BACnet objects according to the following process: The BACnet object instance number is identical to the object number of the ETS. with a 1 bit data type are translated into binary objects. All others become analog objects. The parameter Object Mode (INPUT, OUTPUT, VALUE) completes the transformation to a BACnet object. On BACnet the IP Gateway KN/BACnet N 143 appears as an Application Specific Controller (B-ASC) with up to 250 BACnet objects. BACnet clients may set up to 455 BACnet Siemens AG , page 1 / 20 Technical manual Infrastructure and Cities Sector, Building Technologies Control Products and Systems Siemens AG 2014 Update: P. O. Box , D Regensburg Subject to change without further notice /1
2 change-of-value (COV) subscriptions for these 250 BACnet objects. A common memory space is available for the administration of the COV subscriptions and priority arrays. This resource optimization is based on the fact that subscriptions are required for objects which send from KN to BACnet whilst priority arrays are for objects sending from BACnet to KN. The maximum number of possible subscriptions is 455 if no priority arrays are used. As each priority array has a size of 64 Byte (16 priority levels of 4 Byte each), the number of possible subscriptions decreases accordingly. The maximum possible number of subscriptions is displayed on the device website once the configuration is complete. When a subscription is registered the BACnet object sends its current value, if a value is available for this object. The validity of a value can be verified via the status property (Failure flag). Initially, the status failure flag for the object types Binary, Binary, Analog and Analog is set to TRUE. Once a value is transmitted from the KN bus or from BACnet (for Binary or Analog ) this status flag is set to FALSE. All Analog and Binary BACnet objects supported by the device support the writeable Out-Of-Service property. When this property is set to TRUE, the communication of the respective object with KN is inhibited. s of objects can then be changed from the BACnet side, which otherwise would not be possible. changes of objects with set Out-Of-Service property are also indicatedvia the object status flag Overridden. The Out- Of-Service flag handling is especially important for finding errors in complex systems. When the description of an object is requested from the BACnet side (ReadProperty Description ), the description text is automatically generated and assembled from the object name, BACnet identifier and KN group address data separated by a colon ( : ). The device is equipped with a web server presenting the configuration and current values in an overview page. This presentation is helpful for testing purposes and for documentation of the interface between KN and BACnet. The web page contains a header section showing general device specific information: Device name BACnet instance number of the device MAC address IP address Netmask Gateway address Physical KN address Number of configured objects Maximum number of possible COV subscriptions Number of binary input objects Number of binary output objects Number of binary value objects Number of analog input objects Number of analog output objects Number of analog value objects Beneath the header is a table listing all configured objects. The table is divided into the following columns: Object number Object name BACnet object ID KN group address Data type Transmission mode Reading during initialisation Unit Object value Object values are not dynamically up-dated on the website. To up-date the objects, please re-load the website. Besides the function as IP Gateway KN-BACnet the device also provides an IP Interface for ETS configuration of the device itself as well as other KN devices of the attached KN line. Behavior at bus voltage failure / recovery Failure of the auxiliary power (DC 24V) results in a functional failure of the device. A bus voltage failure results in a functional failure of the device. On bus voltage recovery the configured actions are executed and, if applicable, new status values are reported. The devices sends I am onto BACnet. Factory default state In the default factory state the device has no Gateway function. The IP address is preset to Technical manual , page 2 / 20 Siemens AG Update: Siemens AG 2014 Control Products and Systems Subject to change without further notice P. O. Box , D Regensburg /2
3 Behavior on unloading the application program When the application program is unloaded with ETS the device does not function. All BACnet objects are still visible but are set to out of sevice. The property data base revision in the BACnet Device is incremented by one. The web server stays in operation. Resetting the device to factory default settings The device cannot be reset to the factory default settings. 2. Communication objects Maximum number of group addresses: 255 Maximum number of assignments: 511 Note The number and names of communication objects visible can vary depending on the parameter settings. The application program already has been loaded in the factory. The device is configured and commissioned with the ETS (Engineering Tool Software) version ETS3 v3.0f or later. With the ETS (Engineering Tool Software) the specific parameters and addresses are assigned appropriately, and downloaded into the device. The following list shows all objects of the device. Which objects are visible and linkable to group addresses is defined via the functions assigned to the inputs. The objects and associated parameter settings are described with the functions. No. Object name Function Number of bits Flags 1 Object 001, switching / On / Off 1 Bit CWTU status Object 001, percent 1 Byte CWTU value [ %] Object 001, 8-Bit [ ] 1 Byte CWTU Object 001, 8-Bit [ ] 1 Byte CWTU Object 001, 16-Bit [ ] 2 Byte CWTU Object 001, 16-Bit [ ] 2 Byte CWTU Object 001, 16-Bit [16-Bit float] 2 Byte CWTU Object 001, 32-Bit [ ] 4 Byte CWTU Object 001, 32-Bit [ Mio Mio] 4 Byte CWTU Object 001, 32-Bit [32-Bit float] 4 Byte CWTU Object 250, switching / On / Off 1 Bit CWTU status Object 250, percent 1 Byte CWTU value [ %] Object 250, 8-Bit [ ] 1 Byte CWTU Object 250, 8-Bit [ ] 1 Byte CWTU Object 250, 16-Bit [ ] 2 Byte CWTU Object 250, 16-Bit [ ] 2 Byte CWTU Object 250, 16-Bit [16-Bit float] 2 Byte CWTU Object 250, 32-Bit [ ] 4 Byte CWTU Object 250, 32-Bit [ Mio Mio] 4 Byte CWTU Object 250, 32-Bit [32-Bit float] 4 Byte CWTU 251 Device Status Status 1 Bit CRT Siemens AG , page 3 / 20 Technical manual Control Products and Systems Siemens AG 2014 Update: P. O. Box , D Regensburg Subject to change without further notice /3
4 3. Functions (, s) For the functions of the IP Gateway KN/BACnet first general configuration settings and then the configuration of the 250 have to be done. Note The number and names of the parameter windows in the ETS menus may vary as they are controlled via parameter settings. Another parameter window may appear if due to dynamically added parameters the space in the first parameter window is exhausted. General settings General This parameter window is used to set - a device name for identification of the device via KNnet/IP, - the type of IP address assignment, - the start and cycle time for Read Requests from status objects, and - the base parameters for communication via BAcnet. Device name IP_Gateway_KN_BACnet_N143 (max. 30 char) (don t use blanks) This parameter assigns a name with up to 30 characters to the IP Gateway KN/BACnet N 143. This name is used for easy recognition of the device when searched ny a KNnet/IP visualization or the ETS. IP address assigment manual input by DHCP Server This parameter determines the type of IP address assignment. By default DHCP is preset for automatic address assignment by a DHCP server. When manual input is selected, two additional tabs for manual input of IP address, subnet mask and the default gateway appear. Start delay for Read on Init 10 seconds 20 seconds 30 seconds 1 minute 2 minutes 3 minutes 4 minutes 5 minutes This parameter determines the time delay after bus voltage recovery before read requests of status objects are started. Delay between Read Requests 100 ms 200 ms 500 ms 1 second 2 seconds This parameter determines the time delay between Read Requests of the individual status objects. Device Instance (must be unique) This parameter defines the unique device ID. The ID is an integer value. range ( ) BACnet Communication Port Use this parameter to change the port number of the BACnet server. The pre-set port is DCC Password This parameter defines the password to control the device on the BACnet side (up to 8 characters). By using the BACnet Service DeviceCommunicationControl the device can be temporarily muted for diagnostic purposes. This means all BACnet services apart from DCC are de-activated in order to re-set the device to its normal status. BACnet communication timeout 100 ms 200 ms ms 1 s This parameter determines the time to wait for the BACnet acknowledgement. Technical manual , page 4 / 20 Siemens AG Update: Siemens AG 2014 Control Products and Systems Subject to change without further notice P. O. Box , D Regensburg /4
5 BACnet communication retries 1 retry 2 retries 3 retries Use this parameter to determine how many times you would like to repeat a request in case of wrong acknowledgement. IP Optional This parameter window is used - to store the installation location as information in the device, - to store a brief description of the device as information in the device itself, and - to determine the use of priority arrays. Device location This parameter can be used to enter an installation location of the device for easier localization in the building. Device description This parameter can be used to enter a breif device description for the device. Up to 30 characters can be used. Usage of priority arrays no This parameter generally determines if priority arrays are available for use. The BACnet standard assumes the usage of priority arrays for the BACnet object types Binary, Binary, Analog and Analog supported by the device. According to the standard the device supports 16 priority levels for each priority supporting BACnet object. The output value of the highest priority (this is the lowest priority number) is active. All other values with lower priority are stored (one value per priority level and object). In most cases this functionality is not required. By default priority arrays are disabled to have the highest possible memory space for COV subscriptions This parameter window is visible when the parameter IP address assignment has been set to manual input. IP address byte 1, byte 2, byte 3, byte 4 This parameter determines the IP address if the IP settings are manually assigned. The factory default value for the IP address is This preset value must be replaced with a valid IP address for the target network. The four bytes of the IP address must be entered individually. The value range for each byte is Subnet mask byte 1, byte 2, byte 3, byte 4 This parameter determines the IP subnet mask if the IP settings are manually assigned. The factory default value for the IP subnet mask is This preset value must be replaced with a valid IP subnet mask for the target network. Valid subnet mask may be e.g or The four bytes of the IP subnet mask must be entered individually. The value range for each byte is Siemens AG , page 5 / 20 Technical manual Control Products and Systems Siemens AG 2014 Update: P. O. Box , D Regensburg Subject to change without further notice /5
6 Gateway address byte 1, byte 2, byte 3, byte 4 This parameter determines the standard gateway address if the IP settings are manually assigned. The factory default value for the standard gateway address is This preset value must be replaced with a valid standard gateway address for the target network. The four bytes of the IP subnet mask must be entered individually. The value range for each byte is The standard gateway forwards IP datagrams to e.g. a computer with an address outside of the local network. If the device shall be configured without a standard gateway then the address shall be used. for the Up to 250 objects can be individually configured for transposition of information from KN to BACnet and vice versa. The communication objects can be configured as either: switching/status on/off (1 bit) 8-bit value (percent value) 8-bit value (unsigned integer) 8-bit value (signed integer) 16-bit value (unsigned integer) 16-bit value (signed integer) 16-bit value (float) 32-bit value (unsigned integer) 32-bit value (signed integer) 32-bit value (float) There is a parameter window for each communication object. The configuration includes - a short description of the object with up to 18 characters, - setting the data type from this list: no object 1 bit 1 Byte ( %) 1 Byte unsigned 1 Byte signed 2 Byte unsigned 2 Byte signed 2 Byte float 4 Byte unsigned 4 Byte signed 4 Byte float - additional settings dependent on the selected data type, - the type of BACnet object (,, ), - selection of the transmission to BACnet (always, on change of value), - whether the status of the object shall be interrogated when the device starts up. Note Representative for all 250 objects only the configuration options for object 1 are described. Switching / Status On/Off (1 bit) 1 Object 001, Switching On / Off 1 Bit CWTU / Status Via this object, dependent on the configuration, the bus telegrams are received from KN and then sent onto BACnet or data is received from BACnet and then sent to KN. Object 1 Object 1 Text This parameter is used to enter a text, which is displayed in the web server as name of the object. The length of the text is limited to 18 characters. Technical manual , page 6 / 20 Siemens AG Update: Siemens AG 2014 Control Products and Systems Subject to change without further notice P. O. Box , D Regensburg /6
7 Data type 1 bit 1 Byte ( %) 1 Byte unsigned 1 Byte signed 2 Byte unsigned 2 Byte signed 2 Byte float 4 Byte unsigned 4 Byte signed 4 Byte float no object This parameter determines the data type of the communication object and at the same time the data type of the corresponding BACnet object. Additionally, the data transposition from KN to BACnet and vice versa is determined by this parameter. Object mode This parameter determines the BACnet object type (,, ). At the same time the configuration selection determines if information is sent to BACnet (, ) or if it is received from BACnet (, ). Transmission to by change BACnet on all events This parameter determines when information is sent to BACnet. by change: Send on change of the object value. on all events: Send when any value is received for the object. Enable Read on Init no This parameter determines if on startup of the device a Read Request for the object value is sent onto the KN bus. 8-bit (Prozentwert) 1 Object 001, percent [ %] 1 Byte CWTU value Via this object, dependent on the configuration, the bus telegrams are received from KN and then sent onto BACnet or data is received from BACnet and then sent to KN. Object 1 Object 1 Text This parameter is used to enter a text, which is displayed in the web server as name of the object. The length of the text is limited to 18 characters. Data type 1 bit 1 Byte ( %) 1 Byte unsigned 1 Byte signed 2 Byte unsigned 2 Byte signed 2 Byte float 4 Byte unsigned 4 Byte signed 4 Byte float no object This parameter determines the data type of the communication object and at the same time the data type of the corresponding BACnet object. Additionally, the data transposition from KN to BACnet and vice versa is determined by this parameter. Object mode This parameter determines the BACnet object type (,, ). At the same time the configuration selection determines if information is sent to BACnet (, ) or if it is received from BACnet (, ). Siemens AG , page 7 / 20 Technical manual Control Products and Systems Siemens AG 2014 Update: P. O. Box , D Regensburg Subject to change without further notice /7
8 Transmission to by change BACnet on all events This parameter determines when information is sent to BACnet. by change: Send on change of the object value. on all events: Send when any value is received for the object. Enable Read on Init no This parameter determines if on startup of the device a Read Request for the object value is sent onto the KN bus. 8-bit (Unsigned integer) 1 Object 001, 8-Bit [ ] 1 Byte CWTU value Via this object, dependent on the configuration, the bus telegrams are received from KN and then sent onto BACnet or data is received from BACnet and then sent to KN. Object 1 Object 1 Text This parameter is used to enter a text, which is displayed in the web server as name of the object. The length of the text is limited to 18 characters. Data type 1 bit 1 Byte ( %) 1 Byte unsigned 1 Byte signed 2 Byte unsigned 2 Byte signed 2 Byte float 4 Byte unsigned 4 Byte signed 4 Byte float no object This parameter determines the data type of the communication object and at the same time the data type of the corresponding BACnet object. Additionally, the data transposition from KN to BACnet and vice versa is determined by this parameter. Object mode This parameter determines the BACnet object type (,, ). At the same time the configuration selection determines if information is sent to BACnet (, ) or if it is received from BACnet (, ). Technical manual , page 8 / 20 Siemens AG Update: Siemens AG 2014 Control Products and Systems Subject to change without further notice P. O. Box , D Regensburg /8
9 Transmission to by change BACnet on all events This parameter determines when information is sent to BACnet. by change: Send on change of the object value. on all events: Send when any value is received for the object. Enable Read on Init no This parameter determines if on startup of the device a Read Request for the object value is sent onto the KN bus. 8-bit (Signed integer) 1 Object 001, 8-Bit value [ ] 1 Byte CWTU Via this object, dependent on the configuration, the bus telegrams are received from KN and then sent onto BACnet or data is received from BACnet and then sent to KN. Object 1 Object 1 Text This parameter is used to enter a text, which is displayed in the web server as name of the object. The length of the text is limited to 18 characters. Data type 1 bit 1 Byte ( %) 1 Byte unsigned 1 Byte signed 2 Byte unsigned 2 Byte signed 2 Byte float 4 Byte unsigned 4 Byte signed 4 Byte float no object This parameter determines the data type of the communication object and at the same time the data type of the corresponding BACnet object. Additionally, the data transposition from KN to BACnet and vice versa is determined by this parameter. Object mode This parameter determines the BACnet object type (,, ). At the same time the configuration selection determines if information is sent to BACnet (, ) or if it is received from BACnet (, ). Siemens AG , page 9 / 20 Technical manual Control Products and Systems Siemens AG 2014 Update: P. O. Box , D Regensburg Subject to change without further notice /9
10 Transmission to by change BACnet on all events This parameter determines when information is sent to BACnet. by change: Send on change of the object value. on all events: Send when any value is received for the object. Enable Read on Init no This parameter determines if on startup of the device a Read Request for the object value is sent onto the KN bus. 16-bit value (Unsigned integer) 1 Object 001, 16-Bit value [ ] 2 Byte CWTU Via this object, dependent on the configuration, the bus telegrams are received from KN and then sent onto BACnet or data is received from BACnet and then sent to KN. Object 1 Object 1 Text This parameter is used to enter a text, which is displayed in the web server as name of the object. The length of the text is limited to 18 characters. Data type 1 bit 1 Byte ( %) 1 Byte unsigned 1 Byte signed 2 Byte unsigned 2 Byte signed 2 Byte float 4 Byte unsigned 4 Byte signed 4 Byte float no object This parameter determines the data type of the communication object and at the same time the data type of the corresponding BACnet object. Additionally, the data transposition from KN to BACnet and vice versa is determined by this parameter. Object mode This parameter determines the BACnet object type (,, ). At the same time the configuration selection determines if information is sent to BACnet (, ) or if it is received from BACnet (, ). Technical manual , page 10 / 20 Siemens AG Update: Siemens AG 2014 Control Products and Systems Subject to change without further notice P. O. Box , D Regensburg /10
11 Transmission to by change BACnet on all events This parameter determines when information is sent to BACnet. by change: Send on change of the object value. on all events: Send when any value is received for the object. Enable Read on Init no This parameter determines if on startup of the device a Read Request for the object value is sent onto the KN bus. 16-bit (Signed integer) 1 Object 001, 16-Bit value [ ] 2 Byte CWTU Via this object, dependent on the configuration, the bus telegrams are received from KN and then sent onto BACnet or data is received from BACnet and then sent to KN. Object 1 Object 1 Text This parameter is used to enter a text, which is displayed in the web server as name of the object. The length of the text is limited to 18 characters. Datentyp 1 bit 1 Byte ( %) 1 Byte unsigned 1 Byte signed 2 Byte unsigned 2 Byte signed 2 Byte float 4 Byte unsigned 4 Byte signed 4 Byte float no object This parameter determines the data type of the communication object and at the same time the data type of the corresponding BACnet object. Additionally, the data transposition from KN to BACnet and vice versa is determined by this parameter. Object mode This parameter determines the BACnet object type (,, ). At the same time the configuration selection determines if information is sent to BACnet (, ) or if it is received from BACnet (, ). Siemens AG , page 11 / 20 Technical manual Control Products and Systems Siemens AG 2014 Update: P. O. Box , D Regensburg Subject to change without further notice /11
12 Transmission to by change BACnet on all events This parameter determines when information is sent to BACnet. by change: Send on change of the object value. on all events: Send when any value is received for the object. Enable Read on Init no This parameter determines if on startup of the device a Read Request for the object value is sent onto the KN bus. 16-bit (Float) 1 Object 001, 16-Bit value [16-Bit float] 2 Byte CWTU Via this object, dependent on the configuration, the bus telegrams are received from KN and then sent onto BACnet or data is received from BACnet and then sent to KN. Object 1 Object 1 Text This parameter is used to enter a text, which is displayed in the web server as name of the object. The length of the text is limited to 18 characters. Data type 1 bit 1 Byte ( %) 1 Byte unsigned 1 Byte signed 2 Byte unsigned 2 Byte signed 2 Byte float 4 Byte unsigned 4 Byte signed 4 Byte float no object This parameter determines the data type of the communication object and at the same time the data type of the corresponding BACnet object. Additionally, the data transposition from KN to BACnet and vice versa is determined by this parameter. Technical manual , page 12 / 20 Siemens AG Update: Siemens AG 2014 Control Products and Systems Subject to change without further notice P. O. Box , D Regensburg /12
13 Unit type no unit (Float value) C (DPT9.001) F ( value by C - DPT9.001) hpa ( value by Pa - DPT9.006) Pa (DPT9.006) kw ( value by W - DPT9.024) W (DPT9.024) kw (DPT9.024) W/m2 (DPT9.022) m/s (DPT9.005) km/h ( value by m/s - DPT9.005) lux (DPT9.004) % Humidity (DPT9.007) s (DPT9.010) A ( value by ma - DPT9.021) ma (DPT9.021) V ( value by mv - DPT9.020) mv (DPT9.020) Use this parameter to select the unit for a 2 Byte float data type. Implicit conversions are also possible. The entry for the KN data input type is important. It means that, for example, the data type (KN unit m/s) can be converted into km/h and transmitted to BACnet. Object mode This parameter determines the BACnet object type (,, ). At the same time the configuration selection determines if information is sent to BACnet (, ) or if it is received from BACnet (, ). Transmission to by change BACnet on all events This parameter determines when information is sent to BACnet. by change: Send on change of the object value. on all events: Send when any value is received for the object. Enable Read on Init no This parameter determines if on startup of the device a Read Request for the object value is sent onto the KN bus. 32-bit (Unsigned integer) 1 Object 001, 32-Bit [ Byte CWTU 296] value Via this object, dependent on the configuration, the bus telegrams are received from KN and then sent onto BACnet or data is received from BACnet and then sent to KN. Object 1 Object 1 Text This parameter is used to enter a text, which is displayed in the web server as name of the object. The length of the text is limited to 18 characters. Data type 1 bit 1 Byte ( %) 1 Byte unsigned 1 Byte signed 2 Byte unsigned 2 Byte signed 2 Byte float 4 Byte unsigned 4 Byte signed 4 Byte float no object This parameter determines the data type of the communication object and at the same time the data type of the corresponding BACnet object. Additionally, the data transposition from KN to BACnet and vice versa is determined by this parameter. Unit type no unit (counter value) Wh (DPT13.010) kwh (DPT13.013) This parameter determines the unit of an unsigned 4 byte data type. Selection of implicit calculations are possible. Object mode This parameter determines the BACnet object type (,, ). At the same time the configuration selection determines if information is sent to BACnet (, ) or if it is received from BACnet (, ). Siemens AG , page 13 / 20 Technical manual Control Products and Systems Siemens AG 2014 Update: P. O. Box , D Regensburg Subject to change without further notice /13
14 Transmission to by change BACnet on all events This parameter determines when information is sent to BACnet. by change: Send on change of the object value. on all events: Send when any value is received for the object. Enable Read on Init no This parameter determines if on startup of the device a Read Request for the object value is sent onto the KN bus. 32-bit (Signed integer) 1 Object 001, 32-Bit value [ Mio Mio] 4 Byte CWTU Via this object, dependent on the configuration, the bus telegrams are received from KN and then sent onto BACnet or data is received from BACnet and then sent to KN. Object 1 Object 1 Text This parameter is used to enter a text, which is displayed in the web server as name of the object. The length of the text is limited to 18 characters. Data type 1 bit 1 Byte ( %) 1 Byte unsigned 1 Byte signed 2 Byte unsigned 2 Byte signed 2 Byte float 4 Byte unsigned 4 Byte signed 4 Byte float no object This parameter determines the data type of the communication object and at the same time the data type of the corresponding BACnet object. Additionally, the data transposition from KN to BACnet and vice versa is determined by this parameter. Object mode This parameter determines the BACnet object type (,, ). At the same time the configuration selection determines if information is sent to BACnet (, ) or if it is received from BACnet (, ). Technical manual , page 14 / 20 Siemens AG Update: Siemens AG 2014 Control Products and Systems Subject to change without further notice P. O. Box , D Regensburg /14
15 Transmission to by change BACnet on all events This parameter determines when information is sent to BACnet. by change: Send on change of the object value. on all events: Send when any value is received for the object. Enable Read on Init no This parameter determines if on startup of the device a Read Request for the object value is sent onto the KN bus. 32-bit (Float) 1 Object 001, 32-Bit value [32-Bit float] 4 Byte CWTU Via this object, dependent on the configuration, the bus telegrams are received from KN and then sent onto BACnet or data is received from BACnet and then sent to KN. Object 1 Object 1 Text This parameter is used to enter a text, which is displayed in the web server as name of the object. The length of the text is limited to 18 characters. Data type 1 bit 1 Byte ( %) 1 Byte unsigned 1 Byte signed 2 Byte unsigned 2 Byte signed 2 Byte float 4 Byte unsigned 4 Byte signed 4 Byte float no object This parameter determines the data type of the communication object and at the same time the data type of the corresponding BACnet object. Additionally, the data transposition from KN to BACnet and vice versa is determined by this parameter. Unit type No unit (float value) C (DPT14.068) F ( value by C - DPT14.068) hpa ( value by Pa - DPT14.058) Pa (DPT14.058) kw ( value by W - DPT14.056) W (DPT14.056) J (DPT14.031) kwh ( value by J - DPT14.031) Hz (DPT14.033) m3 (DPT14.010) This parameter determines the unit of an 4 byte float data type. Selection of implicit calculations are possible. Siemens AG , page 15 / 20 Technical manual Control Products and Systems Siemens AG 2014 Update: P. O. Box , D Regensburg Subject to change without further notice /15
16 Object mode This parameter determines the BACnet object type (,, ). At the same time the configuration selection determines if information is sent to BACnet (, ) or if it is received from BACnet (, ). Transmission to by change BACnet on all events This parameter determines when information is sent to BACnet. by change: Send on change of the object value. on all events: Send when any value is received for the object. Enable Read on Init no This parameter determines if on startup of the device a Read Request for the object value is sent onto the KN bus. Device status 251 Device Status Status 1 bit CRT Via this object the device status is transmitted. The device status indicates if the device is in a not active BACnet communication status (DCC Disabled). This state can be configured via the Device Communication Control Service. The status of the communication object is also displayed by a flashing ERR LED on the device. Technical manual , page 16 / 20 Siemens AG Update: Siemens AG 2014 Control Products and Systems Subject to change without further notice P. O. Box , D Regensburg /16
17 4. BACnet Product Description B-ASC: BACnet Application Specific Controller Conformance Class: Class 3 Data Link Layer Option: BACnet IP, (Annex J) Protocol Implementation Conformance Statement (PICS) Vendor Name: Siemens Vendor Id: 7 Product Name: IP Gateway KN-BACnet Product Model Number: 1.0 PICS Data Link Layer BACnet / IP PICS Character Sets Supported ISO PICS Special Functionality Segmented Requests Supported: Segmented Responses Supported: Routing capabilities: no no no BACnet Stack Application Services Application Service Initiate Execute AcknowledgeAlarm ConfirmedCOVNotification ConfirmedEventNotification GetAlarmSummary GetEnrollmentSummary Subscribe COV UnconfirmedCOVNotification UnconfirmedEventNotification AtomicReadFile AtomicWriteFile AddListElement RemoveListElement CreateObject DeleteObject ReadProperty ReadPropertyConditional ReadPropertyMultiple WriteProperty WritePropertyMultiple DeviceCommunicationControl ConfirmedPrivateTransfer UnconfirmedPrivateTransfer ReinitializeDevice ConfirmedTextMessage UnconfirmedTextMessage TimeSynchronization Who-Has I-Have Who-Is I-Am VT-Open VT-Close VT-Data Authenticate Request Key Siemens AG , page 17 / 20 Technical manual Control Products and Systems Siemens AG 2014 Update: P. O. Box , D Regensburg Subject to change without further notice /17
18 BACnet Supported Object Types BACnet Device Object The obligatory BACnet device object administers central device features. Some of these can be configured via ETS whilst others are implemented statically and cannot be changed. They can only be read as information. Object- Type Properties Access Description Device object-identifier R For example: device(0) object-name R Name as configured in ETS object-type R device system-status R always STATUS_OPERATIONAL vendor-name R Siemens vendor-identifier R 7 model-name R IP Gateway KN-BACnet firmwarerevision R 1.0 applicationsoftware-version R current version 1.0 protocol-version R Implemented BACnet Protocol version 1 protocol-revision R 10 protocolservicessupported R Services (see above) that are supported by the device protocol-objecttypes-supported R List of supported object types object-list R List of configured objects max-apdulength-accepted R 1476 Byte segmentationsupported R NO_SEGMENTATION active covsubscriptions R List of active subscirptions apdu-timeout R Configurable via ETS number-of-apduretries R Configurable via ETS device-addressbinding R List is empty. R 1.0 ( is incremented with each change of configuration) location R Configurable via ETS description R Configurable via ETS priority W Priority Array configuration Databaserevision Object- Type Analog Analog Properties Access Description object-identifier R For example: analog input(1) object-name R Name as configured in ETS object-type R Analog input present-value R Present value status-flags R Always FALSE; in case of KN fault, out of service is set to TRUE. event-state R Always NORMAL out-of-service RW Identical to status flag out-of-service units R According to ETS configuration description R Description text = <object-name>:<objectidentifier>:<kn-groupaddress> Example: Temperatur1:analoginput(9):10/0/5 object-identifier R For example: analogoutput(2) object-name R Name as configured in ETS object-type R Analog-output present-value RW Present value status-flags R Always FALSE; in case of KN fault out of service is set to TRUE. out-of-service RW Identical to status flag out-of-service units R According to ETS configuration priority-array RW Priority array relinquishdefault R Pre-set 0 description R Description text = <object-name>:<objectidentifier>:<kn-groupadress> Example: Temperatur2:analogoutput(2):10/0/6 Technical manual , page 18 / 20 Siemens AG Update: Siemens AG 2014 Control Products and Systems Subject to change without further notice P. O. Box , D Regensburg /18
19 Object- Type Analog Binary Properties Access Description object-identifier R For example: analogvalue(3) object-name R Name as configured in ETS object-type R Analog-input present-value R Present value status-flags R Always FALSE; in case of KN fault, out of service is set to TRUE. out-of-service RW Identical to status flag out-of-service units R According to ETS configuration priority-array RW Priority array relinquishdefault R Pre-set 0 description R Description text= <object-name>:<objectidentifier>:<kn-groupaddress> Example: Temperatur2:analogvalue(3):10/0/6 object-identifier R For example: binaryinput(4) object-name R Name as configured in ETS object-type R Binary-input present-value R Present value status-flags R Always FALSE; in case of KN fault, out of service is set to TRUE. out-of-service RW Identical to status flag out-of-service polarity R Always NORMAL description R Description text = <object-name>:<objectidentifier>:<kn-groupaddress> Example: Switch1:binaryinput(4):10/1/8 Object- Type Binary Binary Properties Access Description object-identifier R For example: binaryoutput(5) object-name R Name as configured in ETS object-type R binary-output present-value R Present value status-flags R Always FALSE; in case of KN fault. out of service is set to TRUE. out-of-service RW Identical to status flag out-of-service polarity R Always NORMAL priority-array RW Priority array relinquishdefault R Pre-set inactive description R Description text= <object-name>:<objectidentifier>:<kn-groupaddress> Example: Switch1:binaryoutput(5):10/1/9 object-identifier R For example: binaryvalue(6) object-name R Name as configured in ETS object-type R binary-value present-value R Present value status-flags R Always FALSE; in case of KN fault, out of service is set to TRUE. out-of-service RW Identical to status flag out-of-service polarity R Always NORMAL priority-array RW Priority array relinquishdefault R Pre-set inactive description R Description text = <object-name>:<objectidentifier>:<kn-groupaddress> Example: Switch3:binaryvalue(6):10/1/10 Siemens AG , page 19 / 20 Technical manual Control Products and Systems Siemens AG 2014 Update: P. O. Box , D Regensburg Subject to change without further notice /19
20 Space for notes Technical manual , page 20 / 20 Siemens AG Update: Siemens AG 2014 Control Products and Systems Subject to change without further notice P. O. Box , D Regensburg /20
Table of contents. Use of the application program. GAMMA instabus Application program description. July B CO IP Gateway KNX-BACnet
Table of contents Use of the application program... 1 1.Functional description... 2 Behavior at bus voltage failure / recovery... 4 Factory default state... 4 Behavior on unloading the application program...
More informationBACnet Protocol Implementation Conformance Statement
BACnet Protocol Implementation Conformance Statement Vendor Name: McQuay International Product Name: MicroTech Communications Gateway for BACnet Product Model Number: BACdrop Product Description The MicroTech
More informationWT-BAC-IP Gateway Protocol Implementation Conformance Statement
WT-BAC-IP Gateway Protocol Implementation Conformance Statement Technical Bulletin WT-BAC-IP Code No. LIT-12011936 Issued June 2017 Refer to the QuickLIT Web site for the most up-to-date version of this
More informationDIN EN ISO : (E)
DIN EN ISO 16484-5:2014-09 (E) Building automation and control systems (BACS) - Part 5: Data communication protocol (ISO 16484-5:2014); English version EN ISO 16484-5:2014, only on CD-ROM Contents Page
More informationZoning System TEC2647Z-2 and TEC2647Z-2+PIR Zone Controllers Protocol Implementation Conformance Statement
Zoning System TEC2647Z-2 and TEC2647Z-2+PIR Zone Controllers Protocol Implementation Conformance Statement Technical Bulletin TEC2647Z-2 and TEC2647Z-2+PIR Code No. LIT-12011399 Issued March 9, 2009 Supersedes
More informationNS Series CO 2 Network Zone Sensors Protocol Implementation Conformance Statement
NS Series CO 2 Network Zone Sensors Protocol Implementation Conformance Statement NS-BCN7004-0, NS-BCN7004-2 Code No. LIT-12011581 Issued November 9, 2011 Supersedes April 12, 2011 Refer to the QuickLIT
More informationPROTOCOL IMPLEMENTATION CONFORMANCE STATEMENT (NORMATIVE) (This annex is part of this Standard and is required for its use.)
PROTOCOL IMPLEMENTATION CONFORMANCE STATEMENT (NORMATIE) (This annex is part of this Standard and is required for its use.) BACnet Protocol Implementation Conformance Statement Date: 2013 endor Name: Abies
More informationETC Reference Guide BACnet PICS for P-CCS
BACnet PICS for P-CCS Overview This reference guide defines the BACnet (PICS) for use with ETC s Unison Paradigm Central Control Server. BACnet Vendor Name: Electronic Theatre Controls, Inc. (ETC) BACnet
More informationProduct and Application Description
Technical Product-Information Product and Application Description The IP Gateway KNX-BACnet N 143 is is a DIN rail mounted device connecting a KNX installation with a system using BACnet/IP communication.
More informationS4 Open: BACnet N2 Router
BACnet Date: 10/21/2014 Vendor Name: The S4 Group, Inc. Product Name: S4 Open: BACnet-N2 Router Product Model Number: -16, -32, -64, -128, or -256 Application Software Version: 1.21 Firmware Revision:
More informationNS Series Temperature and Humidity Network Zone and Discharge Air Sensors Protocol Implementation Conformance Statement
NS Series Temperature and Humidity Network Zone and Discharge Air Sensors Protocol Implementation Conformance Statement Technical Bulletin NS-AHx7x0x-x, NS-APx7x0x-0, NS-ATx700x-x, NS-BHx7x0x-0, NS-BPx700x-0,
More informationFunctional Specifications Gateway
Functional Specifications Gateway IntesisBox-BACnet-ModBusRTU V4 1. BACnet Protocol Implementation Conformance Statement (PICS)... 2 1.1 BACnet Standardized Device Profile (Annex L):... 2 1.2 Segmentation
More informationProduct Implementation Conformance Statement bcx1-r
PICS bc1-r Product Implementation Conformance Statement bc1-r Date: October 4, 2005 Vendor Name: TAC Product Name: bc1 Product Model Number: bc1-r Applications Software Version: 4.4 Firmware Revision:
More informationUse of the application program. 1. Functional description. instabus EIB Application Program Description. August 2016.
IP- 001031 Table of contents Use of the application program 1 1. Functional description 1 2. Communication objects 4 3. s 4 General 4 Routing (Bus > IP) 4 Routing (IP > Bus) 5 IP 5 Setting the additional
More informationUse of the application program
Table of contents Use of the application program 1 1. Functional description 1 2. Communication objects 3 3. Parameters 3 IP Settings 3 Setting the additional individual address of the IP Interface with
More informationTest report. on the conformance of the tested functionality of BACnet implementations according to ANSI/ASHRAE No SAG.001.
Test report on the conformance of the tested functionality of BACnet implementations according to ANSI/ASHRAE 135-2001 No. 04.61.SAG.001.1 Initial test This PDF document is verbatim to the original report
More informationUse of the application program. Contents overview. Gamma instabus Application program description. November 2016
Use of the application program Product family: Product type: Manufacturer: Application: Name: Description: Order no: Application: Name: Description: Order no: Lighting Dimmer Siemens Switch-/Dimming Actuator
More informationBTL Listed March 2013
BTL Listed March 2013 STRATO Automation BACnet Protocol Implementation Conformance Statement Date: March 8 th, 2013 Product name : BACzone 424 Applications Software Version : 0.1 Firmware Revision: 2.139
More informationApplication program usage. Functional description. instabus EIB Application Program Description. December IP-Router
Application program usage Product family: Product type: Manufacturer: Name: Order-No.: System devices IP- Siemens Functional description IP N146 5WG1 146-1AB01 The IP N146 is a DIN rail mounted device.
More informationMULTICAL 403 MULTICAL 603
Protocol Implementation Conformance Statement (PICS) MULTICAL 403 MULTICAL 603 Kamstrup A/S Industrivej 28, Stilling DK-8660 Skanderborg T: +45 89 93 10 00 info@kamstrup.com kamstrup.com Contents BACnet
More informationQC BAC-BOX PIC STATEMENT
QC BAC-BO PIC STATEMENT BACnet Protocol Implementation (PIC) Statement QUATROSENSE ENVIRONMENTAL LTD. 5935 OTTAWA STREET, PO BO 749 (RICHMOND) OTTAWA, ONTARIO CANADA K0A 2Z0 PHONE: (613) 838-4005 FA: (613)
More informationApplication Program Description
Using the application program Product family: Product type: Manufacturer: Communication Interface IPAS GmbH Name: 3622-BacnetServer-01-0112, V1.2 Order number: 3622-141-12 Content: Function The ComBridge
More informationBuilding Product CCM08 Series BACnet Central Control Module User Manual
Building Product CCM08 Series BACnet Central Control Module User Manual 2007.10 1 1. connect diagrammatic sketch (1)CCM08 interfaces diagrammatic sketch An Ethernet interface connected to BACnet/IP network.
More informationBACnet RIB March,
BACnet RIB March, 26 2018 Protocol Implementation Conformance Statement Vendor Name: Functional Devices, Inc. Product Name: BACnet RIB Product Model Number: RIB[*]24B-BCAI Applications Software Version:
More informationCarbon Monoxide Transmitter
Network Communication The device parameters must be set before connection to the network and will ensure each device will have a unique MAC address and Device Instance for startup. On startup, the MAC
More informationBACnet Protocol Implementation Conformance Statement (PICS) MULTICAL 62/601/602/6L2/6M2/801
BACnet Protocol Implementation Conformance Statement (PICS) MULTICAL 62/601/602/6L2/6M2/801 Contents Product Description... 3 BACnet Standardized Device Profile (Annex L)... 3 List all BACnet Interoperability
More informationUse of the application program
Use of the application program Product family: Product type: Manufacturer: Name: Order no.: Name: Order no.: Name: Order no.: Name: Order no.: Name: Order no.: Name: Order no.: Name: Order no.: Name: Order
More informationIntesisBox BACnet IP Server Notifier ID3000 and Morley DXc fire panel series. User Manual r1.1 eng
IntesisBox BACnet IP Server Notifier ID3000 and Morley DXc fire panel series User Manual r1.1 eng Intesis Software S.L. 2015 All Rights Reserved. Information in this document is subject to change without
More informationBACnet RIB July 1, 2014
BACnet RIB July 1, 2014 Protocol Implementation Conformance Statement Vendor Name: Functional Devices, Inc. Product Name: BACnet RIB Product Model Number: RIBTW24B-BCAO Applications Software Version: v1.07
More informationBACnet MS/TP-module. Data sheet. for MULTICAL 403 and 603
Data sheet BACnet MS/TP-module for MULTICAL 403 and 603 BTL certified and listed Compatible with ANSI/ASHRAE 135/ISO 16484-5 Complies with BACnet Application Specific Controller Profile Communication speed
More informationField Equipment Controllers Protocol Implementation Conformance Statement
Field Equipment Controllers Protocol Implementation Conformance Statement Technical Bulletin MS-FECx6xx-xxx, MS-VMAx6xx-xxx, MS-IOMx7xx-xxx Code No. LIT-12011100 Software Release 6.0 Issued April 3, 2013
More informationMXB-50 BACnet Interface for Mitsubishi Air-Conditioning
MXB-50 BACnet Interface for Mitsubishi Air-Conditioning Installation and User Guide www.microtrol.co.uk BACnet TM is a registered trademark of ASHRAE (American Society of Heating, Refrigerating and Air-
More informationBACnet IP for Quantum
for 1 07.10.08 Description: License for lighting hub to enable integration which allows control of EcoSystem ballasts and modules in Lutron s lighting control system. BACNet IP is embedded in the Lighting
More informationBACnet RIB July,
Functional s, Inc. 101 Commerce Drive Sharpsville, IN 46068 Toll-Free: Office: Fax: (800) 888-5538 (765) 883-5538 (765) 883-7505 Email: Website: sales@functionaldevices.com www.functionaldevices.com BACnet
More informationPG AB Hochiki FireNet to BACnet IP Protocol Converter
PG-133-103-AB Hochiki FireNet to BACnet IP Protocol Converter PG-133-103-AB is highly powerful, superior, completely configurable and productive Building & Industrial Automation gateway for integrators
More informationUse of the application program
Use of the application program Product family: Product type: Manufacturer: Output Binary Siemens Name: Switching Actuator N 53/ Order no.: 5WG 53-AB Name: Switching Actuator N 52/ Order no.: 5WG 52-AB
More informationProcon BAC-A/50. Installation Instructions MITSUBISHI ELECTRIC
Installation Instructions Procon BAC-A/50 MITSUBISHI ELECTRIC BACnet TM is a registered trademark of ASHRAE (American Society of Heating, Refrigerating and Air- Conditioning Engineers, Inc.) 1. Product
More informationPG AA BACnet IP to Modbus RTU Protocol Converter
PG-103-100-AA BACnet IP to Modbus RTU Protocol Converter PG-103-100-AA is highly powerful, superior, completely configurable and productive Building & Industrial Automation gateway for integrators to effortlessly
More informationApplication program usage. Functional description. instabus EIB Application Program Description. March IP-Router
IP- 001002 Application program usage Product family: Product type: Manufacturer: Name: Order-No.: System devices IP- Siemens Functional description IP N146 5WG1 146-1AB01 The IP N146 is a DIN rail mounted
More informationnbacnet Plug-In Sensorview to BACnet IP Software Plug-In Module
Catalog Number: Date: Project: OVERVIEW The nlight SensorView BACnet IP Software Plug-in module allows a Building Management System (BMS) to communicate to an nlight system. This plug-in module functions
More informationGateway for integration of Modbus RTU slave devices into BACnet IP based systems.
IntesisBox BACnet/IP Server - RTU master Gateway for integration of RTU devices into based systems Integrate any RTU device into your BACnet control system Ethernet RS485 (can be also RS232 for single
More informationBACnet Gateway for VRF System UTY-VBGX
UTY-VBGX Instruction Manual Issue Date: 05/0217 r1.3 eng FUJITSU GENERAL LIMTED FUJITSU GENERAL LIMITED 2017 All rights reserved Information in this document is subject to change without notice. The software
More informationIntesisBox BACnet IP Server - M-Bus
IntesisBox Server - M-Bus Gateway for integration of M-Bus meters into BACnet/IP based control systems Integrate M-Bus meters into your BACnet/IP control system BACnet/IP Ethernet RS232 RS232 / RS485 to
More informationFunctional description. Use of the application program. GAMMA instabus Application program description. June C0 Sensor Switch
Use of the application program Functional description Product family: Product type: Manufacturer: Push button Push button, 1 4 fold Siemens The touch sensors have one, two or four vertically arranged pairs
More informationD-100 FLOW DISPLAY BACnet Network Interface Installation Guide
BACnet D-100 FLOW DISPLAY BACnet Network Interface Installation Guide 11451 Belcher Road South, Largo, FL 33773 USA Tel +1 (727) 447-6140 Fax +1 (727) 442-5699 0635-11 / 18341 www.onicon.com sales@onicon.com
More informationProduct Implementation Conformance Statement bcx-4040
PICS bc-4040 Product Implementation Conformance Statement bc-4040 Date: December 6, 2004 Vendor Name: Andover Controls Corporation Product Name: Continuum Product Model Number: bc-4040 Applications Software
More informationCarbon Monoxide Transmitter
Network Communication The device parameters must be set before connection to the network and will ensure each device will have a unique MAC address and Device Instance for startup. On startup, the MAC
More informationFieldServer Protocol Driver Sheet BACnet Combined DFS
1 DESCRIPTION 3 CONNECTION INFORMATION The BACnet 1 suite of drivers is designed to work with the FieldServer products. One or more drivers using different Data Link Layer options could be configured to
More informationTitan Products NetMaster TP-NM-R/2000
Titan Products NetMaster TP-NM-R/2000 BACnet MS/TP to IP Router Remote Access C-047 08/16 Description The TITAN Products TP-NM-R/2000 NetMaster Router is a high performance, intelligent and secure communications
More informationApplication description for the KNXnet/IP Interface Web
Contents 1. General 1. General... 1 1.1 Basic information about the KNX/EIB BUS... 1 1.2 Application versions......1 1.3 Symbols...1 1.4 Function description... 2 1.5 Short description of the function
More informationApplication program usage. Functional description
Application program usage Product family: Product type: Manufacturer: Name: Order-No.: Controller Controller Siemens Functional description IP Controller N350E 5WG1 350-1EB01 The IP Controller N350E is
More informationAnybus CompactCom 30. BACnet MS/TP NETWORK GUIDE
Anybus CompactCom 30 BACnet MS/TP NETWORK GUIDE HMSI-168-73 2.1 ENGLISH Important User Information Liability Every care has been taken in the preparation of this document. Please inform HMS Industrial
More informationDelta Control Unit (DCU) 3.30 BACNET PROTOCOL IMPLEMENTATION CONFORMANCE STATEMENT
Date: August 14, 2003 Vendor Name: Delta Controls Inc. Product Name: Delta Control Unit Product Model Number: DSC-1616EX, DCU-050, DSM-050 Product Version: 3.30 BACnet Protocol Revision: 3 Product Description:
More informationFOREWORD. In addition, changes to BTL Specified Tests might also contain a yellow highlight to indicate the changes made by this addendum.
[This foreword and the Overview on the following pages are not part of this Test Package. They are merely informative and do not contain requirements necessary for conformance to the Test Package.] FOREWORD
More informationOperation and installation manual KNX IP LineMaster 762 (Art. # 5212) KNX Power supply with integrated KNX IP Router and diagnosis functions
EN Operation and installation manual IP (Art. # 5212) Power supply with integrated IP Router and diagnosis functions Switch LAN IP 1.1.0 IP 2.1.0 1.1.1 1.1.7 2.1.1 2.1.7 1.1.2 1.1.8 2.1.2 2.1.8 1.1.3 1.1.9
More informationProduct Implementation Conformance Statement bcx1-cr
PICS bc1-cr Product Implementation Conformance Statement bc1-cr Date: April, 2008 Vendor Name: Schneider Electric Product Name: bc1 Product Model Number: bc1-cr Applications Software Version: 4.5 Firmware
More informationBACnet Today and the Smart Grid
BACnet Today and the Smart Grid This article was published in ASHRAE Journal, November 2013. Copyright 2013 ASHRAE. Posted at www.ashrae.org. This article may not be copied and/or distributed electronically
More informationentelibus CPU Engine (eb-eng) Firmware
Date: March 27 th, 2017 Vendor Name: Delta Controls Inc. Product Name: entelibus CPU Engine Product Model Number: eb-eng Product Version: 3.40 Firmware BACnet Protocol Revision: 6 Product Description The
More informationASHRAE STANDARDS COMMITTEE
ASHRAE STANDARDS COMMITTEE 2010 2011 H. Michael Newman, Chair Krishnan Gowri Janice C. Peterson Carol E. Marriott, Vice-Chair Maureen Grasso Douglas T. Reindl Douglass S. Abramson Cecily M. Grzywacz Boggarm
More informationIntesisBox KNX - BACnet/IP Client
IntesisBox KN - BACnet/IP Client Gateway for integration of BACnet/IP devices into KN control systems. Integrate Daikin VRV Air Conditioners into your KN system. Daikin VRV system must be equipped with
More informationDelta Controller Engine (DCE) Firmware
Date: August 22, 2011 Vendor Name: Delta Controls Inc. Product Name: Delta Controller Engine Product Model Number: DCE Product Version: 3.40 Firmware BACnet Protocol Revision: 6 Product Description The
More informationDelta ORCAview Date: August 5, 2009 Vendor Name: Delta Controls Inc. Product Name:
Date: August 5, 2009 Vendor Name: Delta Controls Inc. Product Name: ORCAview Product Model Number: DOW-340 Product Version: 3.40 BACnet Protocol Revision: 6 Product Description: ORCAview is an industry
More informationBuilding Operation. Vendor ID 10
StruxureWare TM Building Operation iem3000 Energy Meter Protocol Implementation Statement Date December 12, 2013 Vendor name Schneider Electric Vendor ID 10 Website www.schneider-electric.com Range name
More informationBACnet Combined DFS is not supported on the X20 and X40
1 DESCRIPTION The BACnet 1 suite of drivers is designed to work with the FieldServer products. One or more drivers using different Data Link Layer options could be configured to act as a gateway between
More informationBACnet RIB June 24, 2016
BACnet RIB June 24, 2016 Protocol Implementation Conformance Statement Vendor Name: Functional Devices, Inc. Product Name: BACnet RIB with Accumulator Product Model Number: RIBMNWD12-BC Applications Software
More informationMapping Modbus Registers to BACnet Objects
Mapping Modbus Registers to BACnet Objects HMS Industrial Networks AB Page 1 (20) History Revision Date Description Author 1.00 September 2014 First release SDa Contents 1 Introduction... 3 2 Modbus Device
More informationTable of Contents. NBC User's Manual
User's Manual User's Manual Table of Contents 1. Connections and Power... 3 1.1. Connections and Power for WSXXXX_BR products... 3 2. Initial Configuration... 4 2.1. NBC Network Configuration... 4 2.2.
More informationFieldServer Protocol Driver Sheet BACnet Combined
DESCRIPTION The BACnet 1 suite of drivers is designed to work with the FieldServer products. One or more drivers using different Data Link Layer options could be configured to act as a gateway between
More informationBACnet Protocol Implementation Conformance Statement (PICS) der Automationsstation miles-as29/b
+ BACnet Protocol Implementation Conformance Statement (PICS) der Automationsstation miles-as29/b Version V.40-04.12 Stand: 01.12.2004 miles-as29/b: BACnet-PICS V.40-04.12 Stand: 12/04 Seite 1 von 8 BACnet-PICS
More informationHoneywell ComfortPoint TM Open Plant Controller Protocol Implementation Conformance Statement (PICS)
August 2012 Honeywell ComfortPoint TM Open Plant Controller Protocol Implementation Conformance Statement (PICS) Topic: BACnet Protocol Implementation Conformance Statement (PICS) Date: 27 th August 2012
More informationInstallation Manual. DZK BACnet
Installation Manual DZK BACnet InterfacepbilCodarPageNumber TABLE OF CONTENTS Page Overview... 5 Outline and Features... 5 System outline... 5 Specifications and device elements... 6 Functional specifications...
More informationUse of the application program
Use of the application program Product family: Product type: Manufacturer: Name: Order no.: Output Controller Siemens UP 255/11 brightness controller or AP 255/12 brightness controller 5WG1 255-4AB11 or
More informationNovoCon S Digital/Hybrid - High Accuracy Actuator
Description NovoCon S Digital/Hybrid is a high accuracy multi-function actuator, specifically designed for use in combination with Pressure Independent Balancing Control Valve type AB-QM in sizes from
More informationPolling Data from a BACNET/IP device
Application User Guide AUG 071 / Rev. 1.2 Polling Data from a BACNET/IP device How to use the BACNET IO Server to poll data from a BACNET/IP device support.ewon.biz Table of Contents 1. Objective... 3
More informationESAC ebacgw SNMP. Date: Mar 08,2009. Product Model Number: Product Version: 1.0 BACnet Protocol Revision: 3. Product Description:
Date: Mar 08,2009 Vendor Name: ESAC srl Product Name: ebacgw-snmp Product Model Number: Product Version: 1.0 BACnet Protocol Revision: 3 Product Description: ebacgw is a BACnet gateway to SNMP (simple
More informationBACnet Protocol Implementation Conformance Statement
BACnet Protocol Implementation Conformance Statement Products Product Model Number Protocol Revision Software Version Firmware Version SCADA Engine BACnet Operator Workstation SE-BOW 135-1995b (1) 1.0.0.1
More informationCommunication Module BAC-06 for DGC-06 System
Page 1 Mar. 2017 The module is designed for transmitting values from gas measuring systems or gas sensors to BMS or PLC systems that can be connected via Ethernet to a BACnet/IP-network. APPLICATION The
More informationICC. BACnet MS/TP Server Driver Manual INDUSTRIAL CONTROL COMMUNICATIONS, INC Industrial Control Communications, Inc.
INDUSTRIAL CONTROL COMMUNICATIONS, INC. BACnet MS/TP Server Driver Manual August 17, 2017 2017 Industrial Control Communications, Inc. TABLE OF CONTENTS 1 BACnet MS/TP Server... 2 1.1 Overview... 2 1.2
More informationCommunication Module BAC-06 for DGC6 System
Communication Module BAC-06 for DGC6 System Communication Module BAC-06 for DGC6 System The module is designed for transmitting values from gas measuring systems or gas sensors to BMS or PLC systems that
More informationBACnet Simulator User s Manual
BACnet Simulator User s Manual Contents Introduction... 3 Installation... 4 System Requirements... 4 Install... 4 Installed Files... 6 Application Data... 7 Uninstall... 7 Getting Started... 8 Start the
More informationIntesisBox MAPS. Configuration & monitoring software of IntesisBox KNX series. User's manual Issue Date: 06/17 r1.0 eng
IntesisBox MAPS Configuration & monitoring software of IntesisBox KNX series User's manual Issue Date: 06/17 r1.0 eng Intesis Software S.L.U. 2017 All Rights Reserved. Information in this document is subject
More informationBACnet Protocol Implementation Conformance Statement (PICS)
BACnet Protocol Implementation Conformance Statement (PICS) Date: May 24, 2016 Vendor Name: Lutron Electronics Co., Inc. Product Name: Quantum BACnet Integration Applications Version: 2.0 Firmware Revision:
More informationBACnet Protocol Implementation Conformance Statement (PICS)
BACnet Protocol Implementation Conformance Statement (PICS) Date: May 2, 2017 Vendor Name: Lutron Electronics Co., Inc. Product Name: Quantum BACnet Integration Applications Version: 2.0 Firmware Revision:
More informationPowered Roller Controller for DeviceNet
PRC-620-090 TECHNICAL DATA Description The Holjeron Powered Roller Controller for use with DeviceNet has the features needed to handle up to four zones in a material handling system. A Brushless DC Powered
More informationSystem-10 BTU Meter BACnet Network Interface Installation Guide
BACnet ONICON Flow and Energy Measurement System-10 BTU Meter BACnet Network Interface Installation Guide 11451 Belcher Road South, Largo, FL 33773 USA Tel +1 (727) 447-6140 Fax +1 (727) 442-5699 0652-12
More informationHoneywell Novar XIO Remote I/O Protocol Implementation Conformance Statement (PICS)
Feb 2015 Honeywell Novar XIO Remote I/O Protocol Implementation Conformance Statement (PICS) Topic: BACnet Protocol Implementation Conformance Statement (PICS) Date: Feb 2015 Version 2.0 Applicable Products
More informationBrightCore BACnet Lookout V2.2 Product Family
Page 1 BrightCore BACnet Lookout User Guide Essential, Standard and Extended v.2.2 Page 2 Copyright 2013 by ELMA Kurtalj ltd. All rights reserved. The contents of this documentation are taken in part from
More informationSwitching Actuators N530, 6AX Switching Actuators N532, 10AX Switching Actuators N534, 16/20AX
Gamma instabus Technical Product nformation Switching Actuators N53, 6AX Switching Actuators N532, 1AX Switching Actuators N534, 16/2AX 4x AC 23V 5WG1 53-1DB31 5WG1 532-1DB31 5WG1 534-1DB31 8x AC 23V 5WG1
More informationhomelynk/spacelynk BACnet Protocol Implementation Conformance Statement
homelynk/spacelynk BACnet Protocol Implementation Conformance Statement Date: December 5th, 2014 Vendor Name: Schneider Electric Industries SAS, EcoBuilding Division Product Name Product Model Number Application
More informationBACnet Protocol Implementation Conformance Statement Unitary Protocol Converter (UPC)
Date: 10/05/2016 Vendor Name: OEMCtrl Product Name: Unitary Protocol Converter Product Model Number: UPC Applications Software Version: Firmware Revision: 6.00a BACnet Protocol
More informationNuvo KNX InterfacePoint Integration Guide
Content Adding the Insert The Nuvo/KNX Interface in ETS Configure the Parameters Naming and IP Settings Datapoints Control Datapoints Feedback Datapoints Configure Group Address Configuration Connection
More informationBACnet Protocol Implementation Conformance Statement
BACnet Protocol Implementation Conformance Statement Date: December 1 st, 2015 Vendor Name: Danfoss A/S Product Name: VLT HVAC Drive FC-102 Product Model Number: FC-102 Applications Software Version: 1.6
More informationSystem-10 BTU Meter BACnet Network Interface Installation Guide
BACnet System-10 BTU Meter BACnet Network Interface Installation Guide 0652-3 1500 North Belcher Road, Clearwater, FL 33765 Tel (727) 447-6140 Fax (727) 442-5699 www.onicon.com sales@onicon.com 04-12 System-10-BAC
More informationIntesisBox Modbus Server Siemens Synova FC330A
IntesisBox Modbus Server Siemens Synova FC330A User's Manual V10 r10 eng Intesis Software S.L. 2009. All Rights Reserved. Information in this document is subject to change without notice. The software
More informationASHRAE s BACnet Protocol Implementation Conformance Statement (PICS)
ASHRAE s BACnet Protocol Implementation Conformance Statement (PICS) Date: February 7, 2018 Vendor Name: Lutron Electronics Co., Inc. Product Name: myroom BACnet Integration Applications Version: 2.0 Firmware
More informationUse of the application program. Functional description. GAMMA instabus Application program description. April A4 Roller shutter switch
Use of the application program Product family: Product type: Manufacturer: Shutter Switch Siemens Name: Roller shutter switch N 523/03 Order no.: 5WG1 523-1AB03 Functional description Application The roller
More informationBACnet RIB Jan
BACnet RIB Jan 29 2013 Protocol Implementation Conformance Statement Vendor Name: Functional Devices, Inc. Product Name: BACnet RIB with Accumulator Product Model Number: RIBMNWD12-BC Applications Software
More informationOperation and installation manual KNX IP Multi IO 580 (48I/O) Application. 2. Factory default settings. 1. Installation and connection ❹ ❼ ❻ ❷
EN ❶ Operation and installation manual KNX IP Multi IO 580 (48I/O) (Art. # 5238) KNX IP Multi IO with 48 configurable In- and Outputs ❸ ❹ ❼ ❺ ❽ ❻ ❷ ❶ ❶ ❶ Inputs and Outputs 1-48 ❷ LAN Connector ❸ OLED
More informationBACnet OPC Server User s Manual
BACnet OPC Server User s Manual Contents Introduction... 4 Installation... 8 System Requirements... 8 Install... 9 Installed Files... 11 Application Data... 12 Uninstall... 12 Getting Started... 13 Start
More informationD-100 Flow Display Dual Network Interface Installation Guide. (BACnet & MODBUS)
D-100 Flow Display Dual Network Interface Installation Guide (BACnet & MODBUS) 11451 Belcher Road South, Largo, FL 33773 USA Tel +1 (727) 447-6140 Fax +1 (727) 442-5699 1015-2 / 35094 www.onicon.com sales@onicon.com
More information