Communication. SmartLinx PROFIBUS DP-V1. Operating Instructions

Size: px
Start display at page:

Download "Communication. SmartLinx PROFIBUS DP-V1. Operating Instructions"

Transcription

1 Communication SmartLinx PROFIBUS DP-V1 Operating Instructions Edition 08/2015

2 Safety Guidelines: Warning notices must be observed to ensure personal safety as well as that of others, and to protect the product and the connected equipment. These warning notices are accompanied by a clarification of the level of caution to be observed. Qualified Personnel: This device/system may only be set up and operated in conjunction with this manual. Qualified personnel are only authorized to install and operate this equipment in accordance with established safety practices and standards. Unit Repair and Excluded Liability: The user is responsible for all changes and repairs made to the device by the user or the user s agent. All new components are to be provided by Siemens. Restrict repair to faulty components only. Do not reuse faulty components. Warning: Cardboard shipping package provides limited humidity and moisture protection. This product can only function properly and safely if it is correctly transported, stored, installed, set up, operated, and maintained. This product is intended for use in industrial areas. Operation of this equipment in a residential area may cause interference to several frequency based communications. Note: Always use product in accordance with specifications. Copyright Siemens AG All Rights Reserved This document is available in bound version and in electronic version. We encourage users to purchase authorized bound manuals, or to view electronic versions as designed and authored by Siemens. Siemens will not be responsible for the contents of partial or whole reproductions of either bound or electronic versions. Disclaimer of Liability While we have verified the contents of this manual for agreement with the instrumentation described, variations remain possible. Thus we cannot guarantee full agreement. The contents of this manual are regularly reviewed and corrections are included in subsequent editions. We welcome all suggestions for improvement. Technical data subject to change. Contact Siemens Technical Publications European Authorized Representative at the following address: Technical Publications Siemens Canada Limited Siemens AG PD PA PI LW Industry Sector 1954 Technology Drive, P.O. Box Karlsruhe Peterborough, Ontario, Canada, K9J 7B1 Deutschland techpubs.smpi@siemens.com For a selection of Siemens level measurement manuals, go to: www. siemens.com/processautomation. Under Process Instrumentation, select Level Measurement and then go to the manual archive listed under the product family. For a selection of Siemens weighing manuals, go to: www. siemens.com/processautomation. Under Weighing Technology, select Continuous Weighing Systems and then go to the manual archive listed under the product family. Siemens AG 2015

3 Table of contents Safety notes...1 The Manual...1 Technical support...2 Product feedback...2 SmartLinx PROFIBUS DP-V1...3 Specifications...4 Table of contents Installation... 5 Software...5 Hardware...5 Cable connector...6 Termination switch...6 Operation...7 Operation LED...7 LED status indicators...7 Error conditions of the red diagnostics light...8 Communication setup...9 GSD files...9 Baud rate...9 Bus address...9 Configuring the slave device...10 Module identification Smartlinx Module Type (Read only) Smartlinx Protocol (Read only)...11 Application layer...12 Data access methods...12 Data map...12 Slot index (Acyclic)...14 Data types...20 Integer...20 Bit values...20 Floating point number...20 Unsigned 32-bit Integer (UINT32)...20 Split values...21 Text messages...21 Relay function codes ( Relay Function Only)...23 Troubleshooting...24 General...24 Device not coming online...24 Other devices dropping out...24 Index i

4 Table of Contents ii

5 Safety notes Special attention must be paid to warnings and notes highlighted from the rest of the text by gray boxes. WARNING: Relates to a caution symbol on the product, and means that failure to observe the necessary precautions can result in death, serious injury, and/or considerable material damage. WARNING: Means that failure to observe the necessary precautions can result in death, serious injury, and/or considerable material damage. CAUTION: Means that failure to observe the necessary precautions can result in considerable material damage. Note: Means important information about the product or that part of the operating instructions. SmartLinx PROFIBUS DP-V1 The Manual Note: Please follow the installation and operating procedures for a quick, trouble-free installation and to ensure the maximum accuracy and reliability of your Siemens SmartLinx PROFIBUS DP-V1 module. This manual applies to the SmartLinx PROFIBUS DP-V1 module only. This manual will help you install and connect a Siemens SmartLinx PROFIBUS DP-V1 module, and set it up for communication with a master device on a PROFIBUS DP-V1 network. The manual is targeted at a technical audience in the industrial communications field with a sound working knowledge of PROFIBUS DP-V1. We always welcome questions, comments, or suggestions about operating instructions content, design, and accessibility. Please direct your questions or comments to techpubs.smpi@siemens.com. For the complete library of Siemens operating instructions, go to A5E SmartLinx PROFIBUS DP-V1 Operating Instructions Page 1

6 Technical support Support is available 24 hours a day. To find your local Siemens Automation Office address, phone number and fax number go to: SmartLinx PROFIBUS DP-V1 Click on the tab Contacts by Product then drill down to find your product group (+Process Automation > +Process Instrumentation > +Level Measuring Instruments). Select the team Technical Support. Click on Next. Click on the appropriate continent, then select the country followed by the city. Click on Next. For on-line technical support go to: Enter the device name or order number, then click on Search, and select the appropriate product type. Click on Next. You will be prompted to enter a keyword describing your issue. Then either browse the relevant documentation, or click on Next to a detailed description of your issue to Siemens Technical Support staff. Siemens IA/DT Technical Support Center: phone +49 (0) Product feedback For product feedback, please contact your local Siemens representative or us at Page 2 SmartLinx PROFIBUS DP-V1 Operating Instructions A5E

7 SmartLinx PROFIBUS DP-V1 Note: This product is intended for use in industrial areas. Operation of this equipment in a residential area may cause interference to several frequency-based communications. The Siemens SmartLinx 1 PROFIBUS DP-V1 module is a plug-in communications card designed to interface the MultiRanger 200 HMI or the HydroRanger 200 HMI (also referred to as Siemens device in this operating instructions) to any PROFIBUS DP network. However, to access the Acyclic data map, the master must support either DP-V1 or DP-V2. Only the MultiRanger 200 HMI and the HydroRanger 200 HMI can use this module. PLC master PROFIBUS DP-V1 at 9.6 Kbaud to 12 Mbaud SmartLinx PROFIBUS DP-V1 MultiRanger 200 HMI or HydroRanger 200 HMI Monitored process PROFIBUS is an open standard controlled by PROFIBUS industry groups worldwide. More information is available on the website Note: Siemens does not own the PROFIBUS DP-V1 protocol. All information regarding that protocol is subject to change without notice. 1. SmartLinx is a registered trademark of Siemens Milltronics Process Instruments Inc. A5E SmartLinx PROFIBUS DP-V1 Operating Instructions Page 3

8 Specifications Application Compatible with the MultiRanger 200 HMI and the HydroRanger 200 HMI. Communication settings Baud rate: 9.6 Kbaud to 12 Mbaud, automatically detected. SmartLinx PROFIBUS DP-V1 Termination Cable Switch selectable, open or special active termination as per PROFIBUS specification (see Termination switch on page 6). Belden PROFIBUS cable 3079A, or equivalent. Page 4 SmartLinx PROFIBUS DP-V1 Operating Instructions A5E

9 Installation The SmartLinx module is either pre-installed in the Siemens device or shipped separately for on-site installation. Refer to the operating instructions of your Siemens device for details on module location and physical installation. Software Product Hardware The SmartLinx PROFIBUS DP-V1 module is compatible with the Siemens devices MultiRanger 200 HMI and the HydroRanger 200 HMI. Software revision MultiRanger 200 HMI 2.00 HydroRanger 200 HMI 2.00 Mounting hole Module connector (underside, 34-pin) to Siemens device Mounting hole Mounting hole Installation Terminal block Termination switch Node address switches Status indicators Notes: Install the SmartLinx module so that the mounting holes align and the pin connectors mate correctly. Correct cable routing is important for electromagnetic noise suppression. Follow the routing instructions contained your device operating instructions. A5E SmartLinx PROFIBUS DP-V1 Operating Instructions Page 5

10 Cable connector bus +5V (Vcc) bus ground (GND) A-line B-line bus cable shield RTS Note: RTS is used in some equipment to determine the direction of transmission. In normal applications only A-line, B-line, and shield, are used. Termination switch 1 Termination Setting Switch position Installation +5V Open (not used) 390 OFF Line A Line B GND ON PROFIBUS DP-V1 requires termination of the bus at both end points. See the PROFIBUS DP-V1 specifications for details. 1. The termination switch is not present on all modules. Page 6 SmartLinx PROFIBUS DP-V1 Operating Instructions A5E

11 Operation Communication on the PROFIBUS DP-V1 link is indicated by the SmartLinx LEDs. Operation LED LED Orange blinks as the module is initialized. Green blinks during normal operation. LED status indicators 1 Acyclic Traffic Fieldbus Diagnostics Fieldbus Online Fieldbus Offline Installation LED State Description Acyclic Traffic Fieldbus Online Fieldbus Offline Fieldbus Diagnostics Green OFF Green Green, flashing Red OFF Red OFF OFF Red, flashing Red, flashing Red, flashing Executing a DP-V1 request. No DP-V1 request being executed, or no power. Bus online, data exchange possible. Clear mode. Application stopped. Bus not online, or no power. Bus offline. Bus not offline, or no power. No diagnostics present, or no power. Error in Configuration Data. Error in Parameter Data. Error in initialization of the PROFIBUS communication ASIC. 1. HMS Industrial Networks AB. Fieldbus Appendix: Anybus-S PROFIBUS DP-V1 IM. Hamstad, Sweden: Author. A5E SmartLinx PROFIBUS DP-V1 Operating Instructions Page 7

12 Error conditions of the red diagnostics light 1Hz Error in configuration Indicates that the I/O length variable set during initialization is not equal to the length set during configuration of the network. See Configuring the slave device on page 10 for lengths supported by the SmartLinx module, and see your PLC documentation for setting the I/O length variable. 2Hz Error in user parameter data Indicates that the length and / or contents of the user parameter data set during initialization of the module is greater than the length and/or contents set during configuration of the network. See Configuring the slave device on page 10 for supported lengths. 4Hz Error in initialization Consult your Siemens representative. Operation Page 8 SmartLinx PROFIBUS DP-V1 Operating Instructions A5E

13 Communication setup The SmartLinx PROFIBUS DP-V1 module is a slave on the bus, and does not use any Siemens device parameters for configuration. Set the rotary switches on the module to the desired slave address. Other settings are provided in the GSD file or are automatically detected. GSD files A PROFIBUS master requires the GSD file for each device on the network. The GSD file contains parameter and capability information regarding the slave device. For the PROFIBUS DP-V1 module, the GSD file is HMS_b1813.gsd (included on the accompanying DVD). Baud rate The SmartLinx PROFIBUS DP-V1 module automatically configures itself to the correct baud rate for the PROFIBUS DP-V1 network. Follow the PROFIBUS guidelines with regards to bus length and baud rate. Bus address Set the two rotary switches to the address for this slave. Use a slave address switch in the range 03 to 99. This example shows the value 06. Operation A5E SmartLinx PROFIBUS DP-V1 Operating Instructions Page 9

14 Configuring the slave device Use the configuration software (or any equivalent master commands) to configure the slave. Refer to the information that came with the PROFIBUS master. The Siemens device appears as a modular type slave, and should be configured as shown below. After you import the GSD file, you can find the hardware in the hardware catalogue. If you are using Step 7, go to PROFIBUS DP-V1 > Additional Field Devices > General > Anybus- DPV1 IM. The MultiRanger 200 HMI and the HydroRanger 200 HMI use 19 words of input (Read block) of cyclic data. Example Notes: Data is read and written with the most significant byte (MSB) first. The address and size of the Reads and Writes in the PLC must match the Siemens device. If the PLC size is smaller than the Siemens size, an error will display and only the first portion of the data will be read. PROFIBUS DP-V1 diagnostic bytes are not supported. However, some diagnostic information can be accessed via reading and writing the data areas. See Application layer on page 12. This example assumes that the user is familiar with Step 7 and creating a hardware configuration. 1. Open hardware configuration from the main project window. 2. Install the PROFIBUS DP-V1 GSD file HMSB1813.gsd. 3. Assuming you have a PLC and rack setup with a PROFIBUS DP network, go to the hardware catalog, and select the PROFIBUS DP-V1 card under <PROFIBUS DP><Additional field devices><general><anybus-s DPV1 IM>. Communication setup 4. Drag the Anybus-s DPV1 IM device to the PROFIBUS DP network. 5. In the popup screen, set the slave address, same as you set on the rotary dials on the PROFIBUS DP-V1 card. Page 10 SmartLinx PROFIBUS DP-V1 Operating Instructions A5E

15 6. In the catalog, expand the Anybus-s DP-V1 IM item and select the INPUT modules required. 7. To set up the card, you will need six modules whose combined total byte count must be 19 Words (38 bytes) of input. 8. Save and compile the hardware configuration and download to the PLC. Module identification The following parameters are used together for module identification. Please refer to the Parameters chapter of your Siemens device operating instructions for more details about the subject Smartlinx Module Type (Read only) Identifies the module used. Value Smartlinx Protocol (Read only) Identifies the protocol used: the value varies according to the module, and whether it is a Type 1 or Type 2. Module 0 No module present 1 Anybus DT module 2 Anybus S module Siemens device Module Smartlinx Module Type value Smartlinx Protocol value MultiRanger 200 HMI PROFIBUS DP-V1 2 5 HydroRanger 200 HMI PROFIBUS DP-V1 2 5 MultiRanger 100/200 PROFIBUS DP-V0 2 1 MultiRanger 100/200 DeviceNet 2 37 Communication setup A5E SmartLinx PROFIBUS DP-V1 Operating Instructions Page 11

16 Application layer This section describes the information that can be read and written to the MultiRanger 200 HMI or the HydroRanger 200 HMI. The PLC reads data from the Read block (PLC input) of the PROFIBUS DP-V1 module. Please note that the current firmware of the HydroRanger 200 HMI does not require a Write block (PLC output) to be configured in the PLC, as cyclic writing to the MultiRanger 200 HMI is not supported at this time. Data access methods The PROFIBUS DP-V1 module supports cyclic and acyclic communications for Class 1 and Class 2 master. Data map This section describes the read/write process data available from the MultiRanger 200 HMI or the HydroRanger 200 HMI. Please refer to the Parameters chapter of the your Siemens device operating instructions for details about the parameters used in the table below. Communication setup Word offset 0 2 Description PV Point 1 (Process variable for Point 1) in Programmed units. PV is displayed as an IEEE floating point number. PV Point 1 Status Profi status. PV status byte. See next table for more details. 3 PV Point 1 Signal Strength. 4 6 The Echo Strength (in db) from Transducer 1. The value range is from minimum -30 to maximum 99. PV Point 2 (Process variable for Point 2) in Programmed units. PV Point 2 Status Profi status PV status byte. See next table for more details. Data type Bytes Parameter Float Reading Word 2 n/a Word Echo Strength Float Reading Word 2 n/a Page 12 SmartLinx PROFIBUS DP-V1 Operating Instructions A5E

17 Word offset 7 PV Point 2 Signal Strength The Echo Strength (in db) from Transducer 1. The value range is from minimum -30 to maximum 99. PV Point 3 (Process variable for Point 3) in Programmed units PV Point 3 Status Profi status PV status byte. See next table for more details. Digital inputs The value of the digital inputs are mapped into this Word. Bit 0 is the Digital Input 1. Relay outputs The value of the relay outputs are mapped into this Word. Bit 0 is the Relay Output 1. ma input 1 The value of the analog input is mapped into this Word. Totalizer 1 References the Totalizer parameter within the Siemens device. Totalizer 2 Description References the Totalizer parameter within the Siemens device. Data type Bytes Word Echo Strength Float Reading Word 2 n/a Word Discrete Input 1 Scaled State Word 2 Float Raw ma Input Value UINT32 4 UINT32 4 Parameter Application layer Word 2: PV Point 1 Status Profi status PV status byte. Hexadecimal number 0x80 0x10 0x1f Byte status Good Bad: malfunction Bad: out-of-service A5E SmartLinx PROFIBUS DP-V1 Operating Instructions Page 13

18 Slot index (Acyclic) Application layer The following table shows the slot and index assignments of the different elements (or parameters). The elements are numbered in the order that they are returned. Please see the Parameters chapter of your Siemens device operating instructions for details on the parameters used below. Note: Slot 1 is assigned to Point 1, while Slot 2 is for Point 2. Slot Absolute index 1 or Sensor Mode (2.1.3.) - 2. Material (2.1.6.) - Parameter name (number) - Data type 3. Rate Filter (2.3.5.) - 1 or Vessel Shape (2.7.2.) - 2. Maximum Volume (2.7.3.) - 1 or Fuzz Filter ( ) - 2. Echo Lock ( ) - 3. Echo lock up - 1 or Algorithm ( ) - 2. Blanking (2.2.6.) - 3. Range Extension (2.2.7.) - 4. Submergence Detection ( ) - 5. Shot/pulse Mode ( ) - 6. Echo Time Filtered ( ) - Float Echo Time Raw ( ) - 8. Spike Filter ( ) - UINT16 9. Narrow Echo Filter ( ) - UINT Reform Echo ( ) - UINT Window Sill Number of Short Shots ( ) - 1 or Short Echo Threshold ( ) - 2. Long Echo Threshold ( ) - 3. Short Confidence ( ) - 4. Transducer (2.1.5.) - 5. Empty (2.2.4.) - 6. Span (2.2.2.) - 3. Dimension A (2.7.4.) - Float Dimension L (2.7.5.) - Float Echo lock down - 5. Echo Lock Window ( ) - UINT Number of Long Shots ( ) Short Shot Frequency (2.1.7.) Long Shot Frequency (2.1.8.) Short Shot Duration (2.1.9.) Long Shot Duration ( ) Short Shot Bias ( ) Short Shot Floor ( ) Short Shot Range ( ) - 4. Long Confidence ( ) - 5. Echo Strength ( ) - Total bytes Page 14 SmartLinx PROFIBUS DP-V1 Operating Instructions A5E

19 Slot Absolute index 1 or TVT Type ( ) - 2. TVT Shaper ( ) - 3. TVT db ( ) - 4. TVT ms ( ) - UINT16 5. TVT Slope Minimum ( ) - UINT16 1 or Temperature Source ( ) - 2. Fixed Temperature () - 3. Temp sens alloc start - 1 or Discrete Input Number ( ) - 2. Level Override Value ( ) - 1 or Fill Rate/minute (2.3.2.) - 2. Empty Rate/minute (2.3.3.) - 3. Filling Indicator (2.3.9.) - 4. Emptying Indicator ( ) - 6. Auto Suppression Range ( ) - 7. Hover Level ( ) - 4. Temp sens alloc end - 5. Process Temperature ( ) - 3. Override Time Delay ( ) - 5. Rate Filter (2.3.5.) - 6. Rate Filter Time (2.3.6.) - 7. Rate Filter Distance (2.3.7.) - 1 or 2 59 Shot Delay ( ) - UINT or 2 60 Scan Time ( ) or Primary Measuring Device ( ) - 2. Flow Exponent ( ) - 3. Maximum Head ( ) - 4. Maximum Flow ( ) - 5. Zero Head ( ) - 1 or ma Output Range (2.5.2.) - 2. Current Output Function (2.5.3.) - 3. ma alloc start - 4. ma alloc end /4 ma Level Value (2.6.2.) - 1 or Pump by Rate ( ) - 2. Level Setpoint Variation ( ) - 1 or Flow Maximum ( ) - 2. Flow Minimum ( ) - Parameter name (number) - Data type 6. Flow Time Units ( ) - 7. Flowrate Decimal ( ) - 8. Flowrate Units ( ) - 9. Low Flow Cutoff ( ) ma Level Value (2.6.3.) - 7. Minimum ma Limit (2.5.7.)- 8. Maximum ma Limit (2.5.8.) - Total bytes Application layer A5E SmartLinx PROFIBUS DP-V1 Operating Instructions Page 15

20 Application layer Slot Absolute index 1 or Inflow/discharge Adjust (2.7.7.) - 2. Totalizer Multiplier ( ) - INT8 3. Totalizer Decimal Position ( ) - 1 or Space ( ) - 2. Distance ( ) - 3. Volume ( ) - 1 or Level ( ) - 2. ma value xducer - 1 or Transducer Temperature ( ) - 2. Transducer Temperature Maximum ( ) - 1 or Reading Maximum ( ) - 2. Reading Minimum ( ) - 4. Multiplier ( ) - INT8 5. Mantissa ( ) - 6. Exponent ( ) - INT8 4. Flow ( ) - 5. Head ( ) - 3. Transducer Temperature Minimum ( ) - 1 or 2 70 Sensor Offset (2.2.5.) or 2 71 Auto Sound Velocity ( ) - 1 or 2 72 Auto Zero Head ( ) or Noise Average ( ) - 2. Noise Peak ( ) - 1 or Rate ( ) - 2. Pump Records (3.2.7.) - 1 or 2 75 Auto False Echo Suppression ( ) - 1 or LOE Timer (2.4.2.) - 2. Fail-safe Mode (2.4.4.) - 1 or ma Fail-safe Mode (2.4.8.) - 2. ma Fail-safe Value (2.4.9.) - 1 or Breakpoint Level - 2. Breakpoint Volume - 3. Noise minimum Material Level (2.4.5.) or TVT Shaper ( ) - INT8 1 1 or PMD Dimensions ( ) or Head 1 ( ) - 2. Flow 1 ( ) Scan Time ( ) Level ( ) - 2. ma Value Transducer - Parameter name (number) - Data type Total bytes Page 16 SmartLinx PROFIBUS DP-V1 Operating Instructions A5E

21 Slot Absolute index Reading Maximum ( ) - 2. Reading Minimum ( ) Scaled ma Input Value (2.6.5.) - 2. Raw ma Input Value (2.6.6.) ma Input Range (2.6.1.) /4 ma Level Value (2.6.2.) Discrete Input 1 Scaled State ( ) - 3. ma Input ( ) ma Level Value (2.6.3.) - 4. ma Damp Filter (2.6.4.) Discrete Input 1 ( ) TS-3 Temperature ( ) - 2. TS-3 Temperature Maximum ( ) LOE Timer (2.4.2.) - 2. Fail-safe Mode (2.4.4.) - 3. TS-3 Temperature Minimum ( ) - 3. Material Level (2.4.5.) Milliamp Output (2.5.9.) Breakpoint Level - 2. Breakpoint Volume Vessel Shape (2.7.2.) - 2. Maximum Volume (2.7.3.) Sensor Mode (2.1.3.) - 2. Material (2.1.6.) - 3. Rate Filter (2.3.5.) - 3. Dimension A (2.7.4.) - 4. Dimension L (2.7.5.) - 4. Transducer (2.1.5.) - 5. Empty (2.2.4.) - 6. Span (2.2.2.) Relay Duration ( ) - INT Preset Applications ( ) Run-ON Interval ( ) - INT32 2. Delay Between Starts ( ) - INT Service Ratio ( ) - 2. Run-ON Duration ( ) - INT32 Parameter name (number) - Data type 3. Pump Group ( ) - 4. Flush Pump ( ) - 3. Power Resumption Delay ( ) - INT32 5. Flush Cycles ( ) - UINT16 6. Flush Interval ( ) - UINT16 7. Flush Duration ( ) - UINT32 Total bytes Application layer Level Source ( ) - 2. Relay Function ( ) - 3. ON Setpoint ( ) - 4. OFF Setpoint ( ) - 5. Relay Interval Setpoint ( ) - INT32 6. Relay Dead Band ( ) - 7. Relay Logic ( ) - 8. Relay Fail-safe ( ) - INT8 20 A5E SmartLinx PROFIBUS DP-V1 Operating Instructions Page 17

22 Application layer Slot Absolute index Relay Logic Test (3.2.5.) Pump Run Time ( ) - 2. Pump Hours ( ) Manufacturer string - n/a 2. DD_revision - n/a 3. Pump Starts ( ) - UINT16 4. Pump Run-ONs ( ) - UINT Product Tag (3.1.1.) - 2. Message (3.1.3.) - 3. Descriptor (3.1.2.) Manufacture Date (3.1.9.) - INT32 2. Serial Number Date - n/a 3. Serial Number Batch - n/a 4. Date Last Configured ( ) - 4. Static Feature Status - INT32 5. Firmware Revision (3.1.7.) Write Protection (5.1.) - INT User PIN (5.2.) - INT Powered Days - INT32 2. Power ON Resets - UINT Comm Bitrate - INT32 2. Comm Addr1 - INT32 3. Comm Addr2 - INT32 4. Comm Size1 - INT32 5. Comm Terminate - INT32 6. Comm Bits - 7. Comm Error - UINT16 8. Comm Error Count - INT32 9. Comm Fieldbus Interface - INT Comm Fieldbus Type - INT Diagnostic information (for testing) Shot Synchro ( ) - 2. Scan Delay ( ) - UINT Units (2.1.1.) Default Auxiliary Reading ( ) - INT16 2. Auxiliary Value - n/a 5 64 Milliamp Output (2.5.9.) ma Control Parameter - n/a Comm Memory Map Communications Timeout (4.3.) - UINT16 2. Protocol (4.4.) - INT8 3. Device Address (4.2.) - INT32 4. Serial Baud Rate (4.5.) - 5. Parity (4.6.) Parameter Index Location (4.11.) - UINT Communications Control (5.4.) - INT16 Parameter name (number) - Data type 6. Data Bits (4.7.) - 7. Stop Bits (4.8.) - 8. Modem Available (4.9.) - 9. Modem Inactivity Timeout (4.10.) - UINT16 Total bytes Page 18 SmartLinx PROFIBUS DP-V1 Operating Instructions A5E

23 Slot Absolute index Soft Key - UINT16 2. Display Delay ( ) - 3. Param Scroll Access Decimal Position ( ) - 2. Convert Reading ( ) Tag (3.1.1.) - 2. Message (3.1.3.) - Parameter name (number) - Data type 3. Descriptor (3.1.2.) - 4. Local Display Backlight ( ) - 5. Main Display - 3. Offset Reading ( ) - 4. Date Last Configured ( ) - Total bytes Application layer A5E SmartLinx PROFIBUS DP-V1 Operating Instructions Page 19

24 Application layer Data types The Siemens device parameters take on many values in various formats, as discussed in the Siemens device operating instructions. For the convenience of the programmer, those values are converted to and from 16-bit integer numbers, since those are easily handled by most PLCs. Integer Integer parameter values are by far the most common. For example, parameter Reading (see the Parameters chapter of your Siemens device operating instructions for details) returns a number representing the current reading (either Level or Volume, depending on the Siemens device configuration). Numeric values must be in the range 20,000 to +20,000 to be valid. If a parameter is requested and its value is more than +20,000, the number 32,767 is returned; if it is less than 20,000, the number 32,768 is returned. If this happens, increase the number of decimal places for that parameter. If a parameter cannot be expressed in terms of percent (example: Span), or has no meaningful value, the special number 22,222 is returned. Try requesting the parameter in units, or refer to the Siemens device operating instructions to understand the format and use of the requested parameter. Bit values Bits are packed into registers in groups of 16 bits (1 word). In this operating instructions, bits are numbered from 00 to 15, with bit 00 referring to the least significant bit and bit 15 referring to the most significant bit MSB LSB Floating point number The IEEE single precision floating point standard representation requires a 32-bit word, which is represented as numbers from 0 to 31, left to right. The first bit is sign bit S, the next eight bits are exponent bits E, and the final 23 bits is fraction F : F F F F F F F F F F F F F F F F F F F F F F F E E E E E E E E S Unsigned 32-bit Integer (UINT32) Large numbers are put into unsigned 32-bit integers. By default, they are set up so that the first word (register) is the most significant word (MSW) and the second word (register) is the least significant word (LSW) depending on the setting of the word order bit. Page 20 SmartLinx PROFIBUS DP-V1 Operating Instructions A5E

25 For example, when reading words 7 and 8, the 32 bits would look as follows: word 7 word 8 15 MSW 0 15 LSW bit integer value (UINT32) 0 The whole is read as a 32-bit integer. Split values Application layer Two parameters may sometimes be combined, forming one value. This pair of numbers is presented as xx:yy. An example is Echo Confidence as shown in Measurement View 2 (see The LCD Display section of your Siemens device operating instructions). In this case, a pair of 8-bit unsigned integers are viewed as a single value. xx yy = the average noise value in db = the peak noise in db The number which corresponds to xx:yy, either for reading or setting a parameter, is determined by the following formula: For storing to the device: value = (xx + 128) x (yy + 128) For reading from the device: xx = (value / 256) 128 yy = (value % 256) 128 where % is the modulus operator. The modulus can be computed by following these steps: value 1 = value / 256 value 2 = remainder of value 1 value 3 = value 2 x 256 yy = value It may simplify parameter to notice: xx = (most significant byte of value) 128 yy = (least significant byte of value) 128 Text messages Note: Used for Level products only If a device parameter returns a text message, that message is converted to an integer and provided in the register. The numbers are shown in the following table Number Text message Invalid value OFF ON Parameter values of multiple points do not match Parameter does not exist. A5E SmartLinx PROFIBUS DP-V1 Operating Instructions Page 21

26 Application layer Number Text message ERR ERR OPEN SHORT PASS FAIL HOLD LO HI DE EN Parameter has not been set Value is less than 20, Value is greater than 20,000 Page 22 SmartLinx PROFIBUS DP-V1 Operating Instructions A5E

27 Relay function codes ( Relay Function Only) Please note that the MultiRanger 200 HMI and the HydroRanger 200 HMI offer more function codes. For details, see their respective operating instructionss. If a device parameter returns a relay function code, that message is converted to a number and is then displayed. The numbers are shown in the following table: Control Relay function code Number Relay Function General Flow Pump Control OFF, relay not used 0 OFF Undesignated Level Alarm 1 Level LoLo Level Alarm 2 Level LL Lo Level Alarm 3 Level L Hi Level Alarm 4 Level H HiHi Level Alarm 5 Level HH In-bounds Alarm 6 In-bounds Out-of-bounds Alarm 9 Out-of-bounds Rate of Level Change Alarm 12 Rate of Change Temperature Alarm 15 Temperature Loss of Echo (LOE) Alarm 20 LOE Transducer Cable Fault Alarm 16 Cable Fault Totalizer 22 Totalizer Flow Sampler 23 Flow Sampler Fixed Duty Assist 25 Fixed Duty Assist Fixed Duty Backup 26 Fixed Duty Backup Alternate Duty Assist 30 Alternate Duty Assist Alternate Duty Backup 31 Alternate Duty Backup Service Ratio Duty Assist 35 Service Ratio Duty Assist Service Ratio Duty Backup 36 Service Ratio Duty Backup First In First Out (FIFO) 40 First In First Out Flush Valve 65 Flush Valve Communication 66 Communication Application layer See Relay Function of your Siemens device operating instructions for full details about this parameter. A5E SmartLinx PROFIBUS DP-V1 Operating Instructions Page 23

28 Troubleshooting Troubleshooting General In all cases, perform the the following: 1. Verify that your device has the correct module by checking parameters Smartlinx Module Type and Smartlinx Protocol. (See the Parameters chapter of your Siemens device operating instructions for details.) 2. Check Hardware Status. (See the Parameters chapter of your Siemens device operating instructions for details.) Below are the possible states: Hardware status PASS FAIL ERR1 Description/action The SmartLinx module is ready for use. Either the module, or the module connector on the Siemens device is defective. The Siemens software doesn t recognize the ID number of the installed module. Please contact your Siemens representative to get a software upgrade or to receive instructions. 3. Make sure the Siemens device is set to a unique address to prevent conflict with any other slave(s) on the bus. 4. Check the configuration of the scanning master to make sure it is functioning properly. Device not coming online If you have configured the Siemens device in the Master and downloaded it to the processor, but the device is not coming online: Check which GSD file you are using to make sure that it is the correct one (see GSD files on page 9). Check the wiring to the module. In particular, check that you have lines A and B connected correctly. Verify that you have set the correct address on the module. Also, please note that the module does not see a charge until the power has been cycled. Verify that the Read and Write block sizes are correct. Other devices dropping out If the network was working fine until you connected to the Siemens device, at which time other devices dropped out: Check the termination switch on the PROFIBUS module. The network cable has to be terminated at both ends of the LAN, but not in between. Check your grounding. The PROFIBUS specifications require that all devices be on the same ground. Improper grounding can cause unpredictable effects. Page 24 SmartLinx PROFIBUS DP-V1 Operating Instructions A5E

29 Index A Acyclic. See also Data. Traffic 7 B Baud rate 9 Bit values. See Data types. Bus address 9 C Cable connector 6 routing 5 Configuration files 9 slave device 10 D Data Access methods 12 Acyclic map (slot index) 14 Cyclic map 12 Data types Bit values 20 Floating point number 20 Integer 20 Split values 21 Text messages 21 UINT32 (Unsigned 32-bit Integer) 20 E Error conditions 8 F Fieldbus Diagnostics 7 Offline 7 Online 7 Floating point number. See Data types. G GSD files 10 H Hardware 5 I Installation 5 Integer. See Data types. L LED 7 M Module identification 11 N Network Address 9 O Operation 7 LED 7 R Relay function codes 23 S Safety 1 Setup communication 9 SmartLinx PROFIBUS DP-V1 3 application compatibility 4 Cable 4 Communication settings 4 intended areas for use 3 interface 3 Specifications 4 Termination 4 Software 5 Split values. See Data types. Status 7 Step 7 10 T Technical support 2 Terminal Block connector 6 Termination switch 6 Text messages. See Data types. Troubleshooting 24 U UINT32 (Unsigned 32-bit Integer). See Data types. Index A5E SmartLinx PROFIBUS DP-V1 Operating Instructions Page 25

30

31

32 For more information Siemens Canada Limited 1954 Technology Drive P.O. Box 4225 Peterborough, ON Canada K9J 7B1 Subject to change without prior notice A5E Rev. AA Siemens AG 2015 Printed in Canada

MARTLINX INTERFACE MODULE

MARTLINX INTERFACE MODULE SMARTLINX INTERFACE MODULE FOR PROFIBUS-DP Instruction Manual December 2001 R MARTLINX INTERFACE MODULE Safety Guidelines Warning notices must be observed to ensure personal safety as well as that of others,

More information

Instruction Manual February smartlinx interface module PROFIBUS-DP

Instruction Manual February smartlinx interface module PROFIBUS-DP Instruction Manual February 2003 R smartlinx interface module PROFIBUS-DP Safety Guidelines Warning notices must be observed to ensure personal safety as well as that of others, and to protect the product

More information

Disclaimer of Liability

Disclaimer of Liability Safety Guidelines: Warning notices must be observed to ensure personal safety as well as that of others, and to protect the product and the connected equipment. These warning notices are accompanied by

More information

Serial Communications Accessories SITRANS RD200/300. Operating Instructions 05/2013 SITRANS

Serial Communications Accessories SITRANS RD200/300. Operating Instructions 05/2013 SITRANS Serial Communications Accessories SITRANS RD200/300 Operating Instructions 05/2013 SITRANS Siemens Auto SIT SITRANS RD300RANS RD300 Safety Guidelines: Warning notices must be observed to ensure personal

More information

Disclaimer of Liability

Disclaimer of Liability Safety Guidelines: Warning notices must be observed to ensure personal safety as well as that of others, and to protect the product and the connected equipment. These warning notices are accompanied by

More information

Instruction Manual February smartlinx interface module MODBUS RTU

Instruction Manual February smartlinx interface module MODBUS RTU Instruction Manual February 2004 smartlinx interface module MODBUS RTU Safety Guidelines Warning notices must be observed to ensure personal safety as well as that of others, and to protect the product

More information

Instruction Manual June smartlinx module DEVICENET

Instruction Manual June smartlinx module DEVICENET Instruction Manual June 2008 R smartlinx module DEVICENET Safety Guidelines: Warning notices must be observed to ensure personal safety as well as that of others, and to protect the product and the connected

More information

SMARTLINX INTERFACE MODULE

SMARTLINX INTERFACE MODULE SMARTLINX INTERFACE MODULE FOR DEVICE NET Instruction Manual December 2001 R Safety Guidelines Warning notices must be observed to ensure personal safety as well as that of others, and to protect the product

More information

SMARTLINX INTERFACE MODULE

SMARTLINX INTERFACE MODULE SMARTLINX INTERFACE MODULE FOR DEVICE NET Instruction Manual PL-583 April 2001 R 33455830 Rev. 1.1 Safety Guidelines Warning notices must be observed to ensure personal safety as well as that of others,

More information

While every effort was made to verify the following information, no warranty of accuracy or usability is expressed or implied.

While every effort was made to verify the following information, no warranty of accuracy or usability is expressed or implied. AG090115 How to configure SIMATIC STEP7 V5.5 to read cyclic data from Objective: To use Siemens SIMATC S7300 PLC to read data from MultiRanger/HydroRanger 200 HMI through SmartLinx PROFIBUS communication

More information

Instruction Manual March smartlinx interface module REMOTE I/O

Instruction Manual March smartlinx interface module REMOTE I/O Instruction Manual March 2004 R smartlinx interface module REMOTE I/O Safety Guidelines Warning notices must be observed to ensure personal safety as well as that of others, and to protect the product

More information

SMARTLINX INTERFACE MODULE

SMARTLINX INTERFACE MODULE SMARTLINX INTERFACE MODULE FOR ALLEN-BRADLEY REMOTE I/O Instruction Manual December 2001 R Safety Guidelines Warning notices must be observed to ensure personal safety as well as that of others, and to

More information

Communication settings: Network configuration can be done via the Anybus IP configuration setup tool or via the on board Web server

Communication settings: Network configuration can be done via the Anybus IP configuration setup tool or via the on board Web server SmartLinx EtherNet/IP instruction and use APPLICATION GUIDE Objective: Show the user how to configure and use an EtherNet/IP SmartLinx communication module. AG082415 While every effort was made to verify

More information

Interface Module for Allen-Bradley Remote I/O Instruction Manual PL-533 September 1999

Interface Module for Allen-Bradley Remote I/O Instruction Manual PL-533 September 1999 Interface Module for Allen-Bradley Remote I/O Instruction Manual PL-533 September 1999 33455330 Rev 2.0 Ultrasonic level Radar At Milltronics, we endeavour to design equipment that is simple to use and

More information

ENVIRORANGER ERS 500 NVIRORANGER ERS 500 USER GUIDE. Instruction Manual PL-600 January Rev. 1.2

ENVIRORANGER ERS 500 NVIRORANGER ERS 500 USER GUIDE. Instruction Manual PL-600 January Rev. 1.2 ENVIRORANGER ERS 500 USER GUIDE Instruction Manual PL-600 January 2001 33456000 Rev. 1.2 NVIRORANGER ERS 500 Safety Guidelines Warning notices must be observed to ensure personal safety as well as that

More information

Network configuration can be done via the Anybus IP configuration setup tool or via the on board Web server.

Network configuration can be done via the Anybus IP configuration setup tool or via the on board Web server. SmartLinx EtherNet/IP instruction and use Objective: Show the user how to configure and use a EtherNet/IP SmartLinx communication module. AG052813 While every effort was made to verify the following information,

More information

Instruction Manual July sitrans RD SOFTWARE

Instruction Manual July sitrans RD SOFTWARE Instruction Manual July 2007 sitrans RD SOFTWARE Safety Guidelines: Warning notices must be observed to ensure personal safety as well as that of others, and to protect the product and the connected equipment.

More information

Instrument Configuration Software March dolphin PLUS

Instrument Configuration Software March dolphin PLUS Instrument Configuration Software March 2004 dolphin PLUS Safety Guidelines: Warning notices must be observed to ensure personal safety as well as that of others, and to protect the product and the connected

More information

EnviroRanger ERS 500 Communications Reference PL-558 Nov. 1999

EnviroRanger ERS 500 Communications Reference PL-558 Nov. 1999 EnviroRanger ERS 500 Communications Reference PL-558 Nov. 1999 33455580 Rev 2.0 Ultrasonic level Radar At Milltronics, we endeavour to design equipment that is simple to use and reliable in its operation,

More information

For SITRANS LUT400 (HART) Manual 02/2014

For SITRANS LUT400 (HART) Manual 02/2014 For SITRANS LUT400 (HART) Manual 02/2014 Safety Guidelines: Warning notices must be observed to ensure personal safety as well as that of others, and to protect the product and the connected equipment.

More information

ENVIRORANGER ERS 500 NVIRORANGER ERS 500 COMMUNICATIONS REFERENCE. Instruction Manual August 2001

ENVIRORANGER ERS 500 NVIRORANGER ERS 500 COMMUNICATIONS REFERENCE. Instruction Manual August 2001 ENVIRORANGER ERS 500 COMMUNICATIONS REFERENCE Instruction Manual August 2001 NVIRORANGER ERS 500 Safety Guidelines Warning notices must be observed to ensure personal safety as well as that of others,

More information

Interface Module. for Allen-Bradley Remote I/O. Instruction Manual PL-533 May Rev 3.0

Interface Module. for Allen-Bradley Remote I/O. Instruction Manual PL-533 May Rev 3.0 Interface Module for Allen-Bradley Remote I/O Instruction Manual PL-533 May 2000 33455330 Rev 3.0 Ultrasonic level Radar At Milltronics, we endeavour to design equipment that is simple to use and reliable

More information

Operator Manual for Profibus

Operator Manual for Profibus PROCESS ANALYSERS SERVOPRO MultiExact Operator Manual for Profibus Part Number: Revision: Language: 05410007A 0 UK English This page intentionally blank LIST OF CONTENTS Section Page 1. DESCRIPTION AND

More information

Siemens SITRANS LUT400 revision 1

Siemens SITRANS LUT400 revision 1 HART Field Device Specification: Siemens SITRANS LUT400 revision 1 Siemens Canada Ltd. 1954 Technology Drive Peterborough, Ontario, Canada K9J 7B1 HART is a registered trademark of the HART Communication

More information

Operating Instructions July milltronics ZSS

Operating Instructions July milltronics ZSS Operating Instructions July 2009 milltronics ZSS Safety Guidelines: Warning notices must be observed to ensure personal safety as well as that of others, and to protect the product and the connected equipment.

More information

Ultrasonic Transmitters SITRANS LU150. Operating Instructions 03/2015 SITRANS

Ultrasonic Transmitters SITRANS LU150. Operating Instructions 03/2015 SITRANS Ultrasonic Transmitters Operating Instructions 03/2015 SITRANS Safety Guidelines Warning notices must be observed to ensure personal safety as well as that of others, and to protect the product and the

More information

A0-10 ANALOG OUTPUT. Instruction Manual April 2001 NALOG OUTPUT

A0-10 ANALOG OUTPUT. Instruction Manual April 2001 NALOG OUTPUT A0-10 ANALOG OUTPUT Instruction Manual April 2001 NALOG OUTPUT Safety Guidelines Warning notices must be observed to ensure personal safety as well as that of others, and to protect the product and the

More information

EL731 PROFIBUS INTERFACE

EL731 PROFIBUS INTERFACE Tel: +1-800-832-3873 E-mail: techline@littelfuse.com www.littelfuse.com/el731 EL731 PROFIBUS INTERFACE Revision 0-A-032816 Copyright 2016 Littelfuse Startco All rights reserved. Document Number: PM-1011-EN

More information

Point Level Transmitters. Pointek CLS200 (Standard) Functional Safety Manual 02/2015. Milltronics

Point Level Transmitters. Pointek CLS200 (Standard) Functional Safety Manual 02/2015. Milltronics Point Level Transmitters Pointek CLS200 (Standard) Functional Safety Manual 02/2015 Milltronics Introduction 1 General safety instructions 2 Pointek Level Instruments Device-specific safety instructions

More information

SCHMIDT Sensor interface PROFIBUS Instructions for use

SCHMIDT Sensor interface PROFIBUS Instructions for use SCHMIDT Sensor interface PROFIBUS Instructions for use Table of contents 1 Important information... 3 2 Intended use... 4 3 Electrical connection... 4 4 Signalizations... 7 5 Startup... 9 6 Technical data...

More information

Instruction Manual February smartlinx interface module MODEM

Instruction Manual February smartlinx interface module MODEM Instruction Manual February 2003 R smartlinx interface module MODEM Safety Guidelines Warning notices must be observed to ensure personal safety as well as that of others, and to protect the product and

More information

Instruction Manual August milltronics ZSS

Instruction Manual August milltronics ZSS Instruction Manual August 2003 milltronics ZSS Safety Guidelines Warning notices must be observed to ensure personal safety as well as that of others, and to protect the product and the connected equipment.

More information

RMx621. Appendix to the operating manual

RMx621. Appendix to the operating manual Appendix to the operating manual RMx621 DP-slave module ( PROFIBUS-coupler ) from V2.01.00 Connecting the RMx621 to PROFIBUS DP via the RS485 serial interface using the external module (HMS AnyBus Communicator

More information

DeviceNet Expansion Board

DeviceNet Expansion Board DeviceNet Expansion Board Catalog No. EXBD05 Installation and Operating Manual 10/02 Table of Contents Section 1 General Information................................................... 1 1 Introduction.......................................................

More information

Additional instructions Memograph M, RSG45 Advanced Data Manager

Additional instructions Memograph M, RSG45 Advanced Data Manager BA01414R/09/EN/01.15 No.: 71302193 Firmware version ENU000A, V2.00.xx Products Solutions Services Additional instructions Memograph M, RSG45 Advanced Data Manager PROFIBUS DP slave Table of contents: 1

More information

DOLPHIN PLUS. Instrument configuration software OLPHIN PLUS

DOLPHIN PLUS. Instrument configuration software OLPHIN PLUS DOLPHIN PLUS Instrument configuration software OLPHIN PLUS Safety Guidelines Warning notices must be observed to ensure personal safety as well as that of others, and to protect the product and the connected

More information

RMx621 /FML621. Appendix to the operating manual

RMx621 /FML621. Appendix to the operating manual Appendix to the operating manual RMx621 /FML621 DP-slave module ( PROFIBUS-coupler ) from V2.01.00 Connecting the RMx621 /FML621 to PROFIBUS DP via the RS485 serial interface using the external module

More information

Profibus DP Expansion Board

Profibus DP Expansion Board Profibus DP Expansion Board Catalog No. EXBD04 Installation and Operating Manual 10/02 MN1393 Table of Contents Section 1 General Information................................................... 1 1 Introduction.......................................................

More information

Ultrasonic Transmitters SITRANS LU150. Operating Instructions

Ultrasonic Transmitters SITRANS LU150. Operating Instructions Ultrasonic Transmitters Operating Instructions Edition 03/2016 Introduction 1 Description 2 Installing and mounting 3 Ultrasonic transmitters Operating Instructions Connecting 4 Commissioning 5 Operating

More information

Output Interfaces for SVS2000 TM Installation & Operation Manual

Output Interfaces for SVS2000 TM Installation & Operation Manual IOM Output Interfaces for SVS2000 TM Installation & Operation Manual Output Interfaces for SVS2000 TM Installation & Operation Manual CONTENTS I. INTRODUCTION... 1 II. INSTALLING THE OUTPUT INTERFACE...

More information

PROFIsafe SITRANS. Pressure transmitter SITRANS P, DS III PROFIsafe series. Product Information 7MF4*34 04/2008 A5E

PROFIsafe SITRANS. Pressure transmitter SITRANS P, DS III PROFIsafe series. Product Information 7MF4*34 04/2008 A5E 1 SITRANS Pressure transmitter SITRANS P, DS III PROFIsafe series Product Information 7MF4*34 04/2008 A5E00732533-02 Safety Guidelines This manual contains notices you have to observe in order to ensure

More information

SBPC-21-PB FifeNet to Profibus Gateway

SBPC-21-PB FifeNet to Profibus Gateway Fife Corporation PO Box 26508, Oklahoma City, OK 73126, U.S.A. Phone: 405.755.1600 / Fax: 405.755.8425 www.fife.com / E-mail: fife@fife.com SBPC-21-PB FifeNet to Profibus Gateway Profibus Operation Manual

More information

Remote Data Manager. SITRANS RD500 Module 8 Inputs, 6 Relay Outputs. Operating Instructions 01/2010 SITRANS

Remote Data Manager. SITRANS RD500 Module 8 Inputs, 6 Relay Outputs. Operating Instructions 01/2010 SITRANS Remote Data Manager SITRANS RD500 Module 8 Inputs, 6 Relay Outputs Operating Instructions 0/200 SITRANS Safety Guidelines Warning notices must be observed to ensure personal safety as well as that of others,

More information

PROFIBUS Slave. X-gateway Interface Addendum. Doc: HMSI , Rev: Connecting Devices TM

PROFIBUS Slave. X-gateway Interface Addendum. Doc: HMSI , Rev: Connecting Devices TM X-gateway Interface Addendum PROFIBUS Slave Connecting Devices TM HALMSTAD CHICAGO KARLSRUHE TOKYO BEIJING MILANO MULHOUSE COVENTRY PUNE COPENHAGEN HMS Industrial Networks Mailing address: Box 4126, 300

More information

Supplemental Manual for Profibus Communications for Brooks MFCs/MFMs/PCs/RTs For SLA5800/SLAMf Series

Supplemental Manual for Profibus Communications for Brooks MFCs/MFMs/PCs/RTs For SLA5800/SLAMf Series Brooks SLA Series-Revision B Profibus Supplemental Manual for Profibus Communications for Brooks MFCs/MFMs/PCs/RTs For SLA5800/SLAMf Series Brooks SLA5800 Series with Profibus Communications Brooks SLAMf

More information

Siemens Spares. Preface 1. Scope of Delivery 2 SIPLUS CMS4000. Product Characteristics 3 ION PROFIBUS DP SPY T001 Installation and Maintenance 4

Siemens Spares. Preface 1. Scope of Delivery 2 SIPLUS CMS4000. Product Characteristics 3 ION PROFIBUS DP SPY T001 Installation and Maintenance 4 Preface 1 Scope of Delivery 2 Product Characteristics 3 Industrial I/O-Node ION PROFIBUS DP SPY T001 Installation and Maintenance 4 6AT8000-1BA00-5XA0 Notes on the CE Mark 5 References 6 Appendix 7 Release

More information

Instruction Manual March airanger XPL PLUS

Instruction Manual March airanger XPL PLUS Instruction Manual March 2005 airanger XPL PLUS Safety Guidelines: Warning notices must be observed to ensure personal safety as well as that of others, and to protect the product and the connected equipment.

More information

Engineering Specifications HydroRanger 200. Multi-Functional Level Control System

Engineering Specifications HydroRanger 200. Multi-Functional Level Control System General Engineering Specifications HydroRanger 200 Multi-Functional Level Control System Scope This section describes the requirements for a multi-functional level controller system. Under this item, the

More information

PROFIBUS DP/CAN Gateway PCA-100. User Manual

PROFIBUS DP/CAN Gateway PCA-100. User Manual PCA-100 REV 4.0 SiboTech Automation Co., Ltd. Technical Support: 021-5102 8348 E-mail: support@sibotech.net Catalog 1 Introduction... 2 1.1 About This Instruction... 2 1.2 Copyright... 2 1.3 Related Products...

More information

Disclaimer of Liability

Disclaimer of Liability Safety Guidelines: Warning notices must be observed to ensure personal safety as well as that of others, and to protect the product and the connected equipment. These warning notices are accompanied by

More information

Installation and Setup. In This Chapter... Installing the H0 PSCM The Profibus Network Configuring the Module

Installation and Setup. In This Chapter... Installing the H0 PSCM The Profibus Network Configuring the Module Installation and Setup 1 2 In This Chapter.... Installing the H0 PSCM The Profibus Network Configuring the Module 2 2 Installing the H0 PSCM Remove the Slot Cover The first step in installing the option

More information

Using the MODBUS Protocol with Athena Series C (1ZC, 16C, 18C, and 25C) Controllers

Using the MODBUS Protocol with Athena Series C (1ZC, 16C, 18C, and 25C) Controllers Using the MODBUS Protocol with Athena Series C (1ZC, 16C, 18C, and 25C) Controllers Athena and Multi-Comm are trademarks of Athena Controls, Inc. MODBUS is a trademark of AEG Schneider Automation, Inc.

More information

Contents General Data Data Exchange Mode Block Model

Contents General Data Data Exchange Mode Block Model Contents About this Document 5 Product Identification 5 Validity 5 Intended Use 5 Functional Principle 6 Trademark 6 1 General Data 7 1.1 Data Rate 7 1.2 Device Address 7 1.3 Ident Number 7 1.4 Configuration

More information

Operating Guide MODBUS (RTU) Communications Option IM/L150 MOD_2. Level Indicator L150 and L160

Operating Guide MODBUS (RTU) Communications Option IM/L150 MOD_2. Level Indicator L150 and L160 Operating Guide MODBUS (RTU) Communications Option IM/L150 MOD_2 Level Indicator L150 and L160 Electrical Safety This equipment complies with the requirements of CEI/IEC 61010-1:2001-2 "Safety requirements

More information

PROFIBUS Interface WM : PD

PROFIBUS Interface WM : PD ふ PROFIBUS Interface WM : PD4000303 This is a hazard alert mark. This mark informs you about the operation of the product. Note This manual is subject to change without notice at any time to improve the

More information

Aotewell SIMATIC S7-PDIAG for S7-300 and S Configuring Process Diagnostic Getting St

Aotewell   SIMATIC S7-PDIAG for S7-300 and S Configuring Process Diagnostic Getting St SIMATIC S7-PDIAG for S7-300 and S7-400 - Configuring Process Diagnostic Getting Started Edition 01/2003 First Steps with S7-PDIAG and ProAgent The Getting Started for This product is not a stand-alonedescription.

More information

BB2 Profibus DP option

BB2 Profibus DP option BB2 Profibus DP option 2017-09-06 MANUS09/17 VER 1.03 Table of contents 1. Introduction... 3 2. A few words about this manual... 3 3. Fieldbus introduction... 3 Network Overview... 3 4. Unpacking... 4

More information

Supplementary instructions Sigma X control type with PROFIBUS

Supplementary instructions Sigma X control type with PROFIBUS Supplementary instructions Sigma X control type with PROFIBUS EN These operating instructions are only valid in combination with the "Operating instructions for diaphragm motor driven dosing pump Sigma

More information

The accessories described in this manual are of the highest quality, carefully designed and built in order to ensure excellent performance.

The accessories described in this manual are of the highest quality, carefully designed and built in order to ensure excellent performance. INTRODUCTION Thank you for choosing our product. The accessories described in this manual are of the highest quality, carefully designed and built in order to ensure excellent performance. This manual

More information

Table of Contents 1 ABOUT THIS DOCUMENT GENERAL COPYRIGHT INFORMATION TERMS ABOUT THE GATEWAY PRODUCT FUNCTIO

Table of Contents 1 ABOUT THIS DOCUMENT GENERAL COPYRIGHT INFORMATION TERMS ABOUT THE GATEWAY PRODUCT FUNCTIO DeviceNet/PROFIBUS-DP Adapter - User Manual REV 4.0 SiboTech Automation Co., Ltd. Technical Support: +86-21-5102 8348 E-mail:gt@sibotech.net Table of Contents 1 ABOUT THIS DOCUMENT...2 1.1 GENERAL... 2

More information

User Guide IM/C250 MOD_3. Modbus (RTU) Communications Option C250 and V250

User Guide IM/C250 MOD_3. Modbus (RTU) Communications Option C250 and V250 User Guide IM/C250 MOD_3 Modbus (RTU) Communications Option C250 and V250 Electrical Safety This instrument complies with the requirements of CEI/IEC 61010-1:2001-2 "Safety requirements for electrical

More information

PAC BI-DP BIM and 8701-CA-BI Carrier

PAC BI-DP BIM and 8701-CA-BI Carrier June 2013 PAC8000 8507-BI-DP BIM and 8701-CA-BI Carrier PROFIBUS DP Bus Interface Module and Carrier The 8507-BI-DP Bus Interface Module (BIM) provides the communications link between the PAC8000 series

More information

SMART RELAY SRW 01 V4.0X

SMART RELAY SRW 01 V4.0X Motors Automation Energy Transmission & Distribution Coatings SMART RELAY SRW 01 V4.0X Profibus DP Communication Manual Profibus DP Communication Manual Series: SRW 01 Firmware Version: V4.0X Language:

More information

HawkEye 45T Display User Manual

HawkEye 45T Display User Manual HawkEye 45T Display User Manual Rev 1.0.1, December 2006 EM-20889-1V101 Safety Guidelines This manual contains notices you have to observe in order to ensure your personal safety, as well as to prevent

More information

Gateway 1400 Reference Manual

Gateway 1400 Reference Manual Profibus-DP Gateway 1400 Reference Manual Copyright All Rights Reserved. No part of this document may be copied, reproduced, republished, uploaded, posted, transmitted, distributed, stored in or introduced

More information

Copyright 1999 by Siemens Energy & Automation, Inc. All Rights Reserved Printed in USA

Copyright 1999 by Siemens Energy & Automation, Inc. All Rights Reserved Printed in USA ! DANGER DANGER indicates an imminently hazardous situation that, if not avoided, will result in death or serious injury. DANGER is limited to the most extreme situations.! WARNING WARNING indicates a

More information

First Steps with S7-PDIAG and ProAgent

First Steps with S7-PDIAG and ProAgent s SIMATIC S7-PDIAG for S7-300 and S7-400 Configuring Process Diagnostics Getting Started Edition 07/2005 First Steps with S7-PDIAG and ProAgent The Getting Started for This product is not a stand-alonedescription.

More information

TRACKER 240 SERIES. Load Cell and Weighing Indicators. A Precision Measurement Instrument with Outstanding Features

TRACKER 240 SERIES. Load Cell and Weighing Indicators. A Precision Measurement Instrument with Outstanding Features TRACKER 240 SERIES Load Cell and Weighing Indicators A Precision Measurement Instrument with Outstanding Features TRACKER 240 SERIES INDICATORS Ratiometric Measurement Tare and Auto Transducer Excitation

More information

S7-300 Programmable Controller

S7-300 Programmable Controller S7-300 Programmable Controller This description belongs to the following documentation packages with the order numbers given: S7 300 Programmable Controller 6ES7 398 8AA02 8BA0 ET 200M Distributed I/O

More information

Automationdirect.com. D i r e c t L o g i c M a g n e t i c P u l s e I n p u t C o p r o c e s s o r F 4-8 M P I

Automationdirect.com. D i r e c t L o g i c M a g n e t i c P u l s e I n p u t C o p r o c e s s o r F 4-8 M P I Automationdirect.com D i r e c t L o g i c 0 5 M a g n e t i c P u l s e I n p u t C o p r o c e s s o r F - 8 M P I Manual Order Number: F-8MPI-M TRADEMARKS AutomationDirect.com is a Trademark of Automationdirect.com

More information

SIMATIC. ET 200S distributed I/O 2AO U HF analog electronic module (6ES7135-4LB02-0AB0) Preface. Properties 1. Parameters 2.

SIMATIC. ET 200S distributed I/O 2AO U HF analog electronic module (6ES7135-4LB02-0AB0) Preface. Properties 1. Parameters 2. SIMATIC ET 200S distributed I/O SIMATIC ET 200S distributed I/O 2AO U HF analog electronic module (6ES7135-4LB02-0AB0) Manual Preface Properties 1 Parameters 2 Diagnostics 3 Analog value representation

More information

Profibus Supplemental Manual for Brooks GF40/GF80 Series Mass Flow Controllers and Meters

Profibus Supplemental Manual for Brooks GF40/GF80 Series Mass Flow Controllers and Meters Installation and Operation Manual Profibus Supplemental Manual for Brooks GF40/GF80 Series Mass Flow Controllers and Meters Brooks GF40/GF80 Series with Profibus Installation and Operation Manual Dear

More information

PROFI-8455 PROFIBUS Remote I/O Unit

PROFI-8455 PROFIBUS Remote I/O Unit PROFI-8455 PROFIBUS Remote I/O Unit Introduction Quick Start User Guide This user guide introduces the user how to implement the PROFI-8455 into their applications in a quick and easy way. Therefore, it

More information

This manual may not be reproduced in whole or in part by any means, without written permission of Accuenergy.

This manual may not be reproduced in whole or in part by any means, without written permission of Accuenergy. Copyright 2008 V1.10 This manual may not be reproduced in whole or in part by any means, without written permission of Accuenergy. The information contained in this document is believed to be accurate

More information

Operation manual. HDOM-Profibus-V0. More options please visit;www.veikong-electric.com

Operation manual. HDOM-Profibus-V0. More options please visit;www.veikong-electric.com Operation manual HDOM-Profibus-V0 More options please visit;www.veikong-electric.com Contents 1 Introduction... 1 1.1 Product description... 1 1.2 HDOM-Profibus-V0 label... 1 1.3 Technical specifications...

More information

G3 Series PROFIBUS DP Technical Manual

G3 Series PROFIBUS DP Technical Manual G3 Series PROFIBUS DP Technical Manual Table of Contents G3 Series PROFIBUS DP Technical Manual PAGE About PROFIBUS-DP...3 Overview...3 G3 PROFIBUS-DP Features...3 Cabling and Drop Line Lengths (as defined

More information

SIMATIC. ET 200S distributed I/O 2AO U ST analog electronic module (6ES7135-4FB01-0AB0) Preface. Properties 1. Parameters 2.

SIMATIC. ET 200S distributed I/O 2AO U ST analog electronic module (6ES7135-4FB01-0AB0) Preface. Properties 1. Parameters 2. SIMATIC ET 200S distributed I/O SIMATIC ET 200S distributed I/O 2AO U ST analog electronic module (6ES7135-4FB01-0AB0) Manual Preface Properties 1 Parameters 2 Diagnostics 3 Analog value representation

More information

A B

A B ET 200U Distributed I/O Station Manual System Overview Technical Description Mechanical and Electrical Configuration ET 200U(DP Siemens): Address Assignment, Starting Up, Diagnosing Faults ET 200U(DP Standard):

More information

Device manual Profibus encoder. RM30xx RN30xx /00 06/2013

Device manual Profibus encoder. RM30xx RN30xx /00 06/2013 Device manual Profibus encoder RM30xx RN30xx 706355/00 06/2013 Contents 1 Preliminary note................................................. 4 1.1 Symbols used...............................................

More information

User Manual Gateway component for EtherNet/IP

User Manual Gateway component for EtherNet/IP User Manual Gateway component for EtherNet/IP PR100066 1/7/2016 Table of Contents KUNBUS GmbH Table of Contents 1 General Information... 3 1.1 Disclaimer... 3 1.2 Notes Regarding this User Manual... 4

More information

Anybus X-gateway. PROFINET IRT (2.32) Interface NETWORK GUIDE

Anybus X-gateway. PROFINET IRT (2.32) Interface NETWORK GUIDE Anybus X-gateway PROFINET IRT (2.32) Interface NETWORK GUIDE SCM-1202-028-EN 1.1 ENGLISH Important User Information Liability Every care has been taken in the preparation of this document. Please inform

More information

Automationdirect.com. D i r e c t L o g i c S D S N e t w o r k M a s t e r. S m a r t D i s t r i b u t e d. S y s t e m M o d u l e

Automationdirect.com. D i r e c t L o g i c S D S N e t w o r k M a s t e r. S m a r t D i s t r i b u t e d. S y s t e m M o d u l e Automationdirect.com D i r e c t L o g i c 4 0 5 S D S N e t w o r k M a s t e r S m a r t D i s t r i b u t e d S y s t e m M o d u l e F 4 - S D S Order Number: F4-SDS-M TRADEMARKS Automationdirect.com

More information

Profibus DP/V1 Interface for Bayard-Alpert Pirani Capacitance Diaphragm Gauge

Profibus DP/V1 Interface for Bayard-Alpert Pirani Capacitance Diaphragm Gauge Communication Protocol Profibus DP/V1 Interface for Bayard-Alpert Pirani Capacitance Diaphragm Gauge BCG450-SP tira41e1 (2005-06) 1 About this Document This document describes the functionality and programming

More information

Installation Instructions

Installation Instructions Installation Instructions 1771-SDN/B DeviceNet Scanner Module Installation Instructions 1 (Catalog Number 1771-SDN/B) Use this document as a guide to installing your 1771-SDN/B Scanner Module. Before you

More information

Ultrasonic Transmitters

Ultrasonic Transmitters Ultrasonic Transmitters THE PROBE Operating Instructions 03/2010 Safety Guidelines: Warning notices must be observed to ensure personal safety as well as that of others, and to protect the product and

More information

Anybus X-gateway. PROFIBUS Master Interface NETWORK GUIDE SCM EN 1.0 ENGLISH

Anybus X-gateway. PROFIBUS Master Interface NETWORK GUIDE SCM EN 1.0 ENGLISH Anybus X-gateway PROFIBUS Master Interface NETWORK GUIDE SCM-1202-104 EN 1.0 ENGLISH Important User Information Liability Every care has been taken in the preparation of this document. Please inform HMS

More information

Protronic 100/500/550. Controllers for process engineering Controllers for industry. Digitric 500. PROFIBUS-DP interface and module

Protronic 100/500/550. Controllers for process engineering Controllers for industry. Digitric 500. PROFIBUS-DP interface and module Protronic 100/500/550 Digitric 500 Controllers for process engineering Controllers for industry PROFIBUS-DP interface and module Manual 42/62-50050 EN Rev. 02 Table of Contents Page Safety and Precautions...

More information

SIMATIC HMI. Software RemoteOperate V2. Preface. Overview 1. Range of functions of the RemoteOperate software. Hardware and software requirements

SIMATIC HMI. Software RemoteOperate V2. Preface. Overview 1. Range of functions of the RemoteOperate software. Hardware and software requirements Preface SIMATIC HMI Software SIMATIC HMI Software Programming Manual Overview 1 Range of functions of the RemoteOperate software 2 Hardware and software requirements 3 Installing RemoteOperate 4 Server

More information

SIMATIC. Function modules FM 351 First Steps in Commissioning. Purpose of the Getting Started. Requirements 2

SIMATIC. Function modules FM 351 First Steps in Commissioning. Purpose of the Getting Started. Requirements 2 Purpose of the Getting Started 1 Requirements 2 SIMATIC Function modules FM 351 First Steps in Commissioning Getting Started Installing the configuration package on the PG 3 FM 351, installing and wiring

More information

Deckblatt. APL Operator Guide SIMATIC PCS 7. Application description June Applikationen & Tools. Answers for industry.

Deckblatt. APL Operator Guide SIMATIC PCS 7. Application description June Applikationen & Tools. Answers for industry. Deckblatt SIMATIC PCS 7 Application description June 2011 Applikationen & Tools Answers for industry. Industry Automation and Drive Technologies Service & Support Portal This article is taken from the

More information

DANGER indicates that death or severe personal injury will result if proper precautions are not taken.

DANGER indicates that death or severe personal injury will result if proper precautions are not taken. SIMATIC ET 200S distributed I/O SIMATIC ET 200S distributed I/O Digital electronic module 4DI DC24V HF (6ES7131-4BD01-0AB0) Manual Preface Properties 1 Parameters 2 Diagnostics 3 04/2007 A5E01077141-01

More information

Motors Automation Energy Transmission & Distribution Coatings. Profibus DP SRW 01. User s Manual

Motors Automation Energy Transmission & Distribution Coatings. Profibus DP SRW 01. User s Manual Motors Automation Energy Transmission & Distribution Coatings Profibus DP SRW 01 User s Manual Profibus DP User s Manual Series: SRW 01 Firmware Version: V6.0X Language: English Document Number: 10000521541

More information

SITOP UPS1600 under STEP 7 V13. SITOP UPS1600 under STEP 7 V13. Introduction. Safety notes. Description. Assigning the IP address

SITOP UPS1600 under STEP 7 V13. SITOP UPS1600 under STEP 7 V13. Introduction. Safety notes. Description. Assigning the IP address Introduction 1 Safety notes 2 Description 3 Assigning the IP address 4 SITOP UPS1600 under STEP 7 V13 Getting Started Installing and configuring the SITOP UPS1600 in STEP 7 5 V13 Parameterizing the SITOP

More information

ST (6ES7132-6FD00-0BB1)

ST (6ES7132-6FD00-0BB1) SIMATIC ET 200SP Digital output module DQ 4x24..230VAC/2A ST (6ES7132-6FD00-0BB1) Manual Edition 02/2014 Answers for industry. DQ 4x24..230VAC/2A ST Preface Guide to documentation 1 SIMATIC ET 200SP DQ

More information

Overview This section describes how to use the LTM R controller via the network port using the Modbus protocol.

Overview This section describes how to use the LTM R controller via the network port using the Modbus protocol. 7.6 Using the Modbus Communication Network Overview This section describes how to use the LTM R controller via the network port using the Modbus protocol. LOSS OF CONTROL WARNING The designer of any control

More information

G5 Weighing Instrument

G5 Weighing Instrument G5 Weighing Instrument Program version 1.4.X Fieldbus Option Manual PM and RM types CONTENTS 1. Introduction... 1-1 General... 1-1 Module installation... 1-2 Ordering information... 1-3 2. Modules...

More information

FACTORY AUTOMATION MANUAL WCS-MBG110 WCS MODBUS RTU INTERFACE MODULE

FACTORY AUTOMATION MANUAL WCS-MBG110 WCS MODBUS RTU INTERFACE MODULE FACTORY AUTOMATION MANUAL WCS MODBUS RTU INTERFACE MODULE With regard to the supply of products, the current issue of the following document is applicable: The General Terms of Delivery for Products and

More information

Catalog 1 Product Overview General Important User Information About the Gateway Function Features Tec

Catalog 1 Product Overview General Important User Information About the Gateway Function Features Tec PROFIBUS DP / Modbus TCP Gateway EP-321MP User Manual REV 1.2 Sibotech Automation Co., Ltd Technical Support: 021-5102 8348 E-mail:support@sibotech.net Catalog 1 Product Overview... 4 1.1 General...4 1.2

More information

SIMATIC. ET 200S IM CPU Interface Module. Introduction. New features 2. Technical specifications 3. Product Information 06/2007 A5E

SIMATIC. ET 200S IM CPU Interface Module. Introduction. New features 2. Technical specifications 3. Product Information 06/2007 A5E SIMATIC ET 200S SIMATIC Introduction 1 New features 2 Technical specifications 3 ET 200S Product Information 06/2007 A5E01159154-01 Safety Guidelines Safety Guidelines This manual contains notices you

More information

SINAMICS G130. Terminal Module 150 (TM150) Operating Instructions 03/2013 SINAMICS

SINAMICS G130. Terminal Module 150 (TM150) Operating Instructions 03/2013 SINAMICS SINAMICS G130 Operating Instructions 03/2013 SINAMICS s Safety information 1 General information 2 SINAMICS SINAMICS G130 Mechanical installation 3 Electrical installation 4 Technical specifications 5

More information