1 ION CHAMBERS UNCOMPROMISING QUALITY Designed with over 30 years of scientific integrity for a broad range of dosimetry measurements in diverse radiation beams

2 Farmer-type Chambers For absolute dosimetry calibrations in water, air or other phantom material MODELS A12 and A12S Constructed of C552 Shonka air-equivalent conducting plastic, providing robust design and excellent conductivity with the shell, collector and guard made of the same material eliminates fragility or flaking of painted conductive layers found in many chambers Farmer-type chamber geometry with the advantage of uniform field characteristics for an isotropic response throughout the chamber Inherently waterproof construction for use in most water phantoms, eliminating the need for additional protective coatings Model A12 is completely characterized in TG-51 & TRS-398 Axially symmetric design, homogeneous construction and uniform spatial resolution ensures maximum collection efficiency Complete guarding results in little to no variation of response throughout the radiation field allowing for more precise measurements Two separate stem pieces of 5.1 cm and 12.7 cm can be coupled together for flexibility of operation and length Chamber vents through a flexible tube surrounding the triaxial cable vent tube is sealed to the chamber body and open near the connector Matching 2.8 mm thick Cobalt-60 buildup cap of C552 Shonka air-equivalent plastic with wooden storage case included Designed to have no variation of polarizing potential and no stem or voltage soakage effects mean the ionization current may be read immediately Model A12 Model A12S MODEL A12 MODEL A12S Rigorous one meter drop test proves ruggedness and reliability.

3 MicroChambers For assessing pinpoint radiation fi elds for IMRT orthovoltage, x-rays, stereotactic and superfi cial skin therapy MODELS 14, A14SL and A16 Axially symmetric design, homogeneous construction and complete guarding for uniform field lines Extremely small volumes allow for exceptional spatial resolution and exact pinpoint characterization of a small area of the beam and beam profile measurements Inherently waterproof construction Uniform isotropic response on cylindrical axis measuring volume Model 14 has two separate, removable stem pieces of 5.1 and 12.7 cm that can be coupled together for easy mounting Models A14SL and A16 have a one-piece, non-removable 5.6 cm stem Chamber vents through a flexible tube surrounding the triaxial cable vent tube is sealed to the chamber body and open near the connector Capable of measuring extremely small field sizes of 4 x 6 mm for Models 14 and A14SL, and 3.4 x 3.4 mm for Model A16 allowing for accurate measurements while minimizing partial volume effects Model cc Model A14SL 0.009cc MODELS 14 & A14SL Model A cc Ref: The Behavior of Several Microionization Chambers in Small Intensity Modulated Radiotherapy Fields, Med. Phys. 31 (10), October 2004 Exradin MicroChambers are ideal for small field size IMRT applications.

4 Miniature Shonka Thimble Chambers For relative dosimetry scanning and measuring points in water, air or other phantom material MODELS 1, A1SL, 2 and A18 Axially symmetric design, homogeneous construction and complete guarding for uniform field lines Small volumes allow for excellent spatial resolution and exact characterization of a small area of the beam in depthdose measurements can also be used for high energy photon and electron beam calibration Inherently waterproof construction for use in most water phantoms eliminating the need for protective coverings Two separate stem pieces of 5.1 and 12.7 cm can be coupled together for easy mounting on Models 1 and 2 Intended for exposure, air kerma measurement and facilitating the determination of absorbed dose water, Model 2 is ideal for routine beam calibration Uniform response on cylindrical measuring volume Excellent saturation characteristics make Model 2 suitable for pulsed radiation Perfect balance between fast scanning speeds and accurate point dose measurements within 1 cm Shell, collector and guard made of extremely robust Shonka conductive plastic for years of durability Chamber vents through a flexible tube surrounding the triaxial cable vent tube is sealed to the chamber body and open near the connector Model 1 Model A1SL Model 2 Model A18 MODELS 1 & A1SL MODEL 2 MODEL A18 Exradin Thimble Chambers provide a perfect balance between fast scanning and point dose measurements.

5 Parallel Plate Chambers For use in routine electron beam measurements and for depth-dose studies in electron, photon, proton and neutron beams MODELS A10, 11, 11TW, MAGNA 1cc and MAGNA 3cc Models A10 and P11 are characterized for TG-51* and TRS-398 Fully guarded for extremely uniform field lines and negligible variation of polarizing potential no need for polarity corrections Exceptionally wide guard rings ensure precision in depth-dose measurement with no perturbation in field lines even at low energies exceeding a 3 mm width as recommended in TG-398 Durable construction with homogeneous conductive plastic means minimal scatter Rigid stem allows accurate positioning of chamber Chamber vents through a flexible tube surrounding the triaxial cable vent tube is sealed to the chamber body and open near the connector (Models A10 and 11) Model 11 inherently waterproof not requiring additional cap or covering Models A10 and 11TW require waterproof caps due to Kapton film windows Model 11 ideally suited with larger volume for routine electron field measurements in a water phantom Cobalt-60 buildup cap available Model A10 is ideally suited for smaller electron field measurements in a water phantom 1 mm waterproof acrylic buildup cap for TG-51 is included Model A10 capable of measuring at zero depth in buildup region of an electron field Model 11 Magna 1cc Model 11TW Magna 3cc Model A10 * Ref: AAPM s TG-51 Protocol for Clinical Reference Dosimetry of High-Energy Photon and Electron Beams, Med. Phys. 26 (9), September 1999 Ref: Calculations for Plane-Parallel Ion Chambers in 60 Co Beams Using the EGSnrc Monte Carlo Code, Med. Phys. 30 (2), February 2003 Exradin Parallel Plate Chambers are characterized for TG-51 and TG-398

6 CT Chambers For performing the measurements necessary for calculating the CTDI, as described in the new AAPM TG Report No. 74 *, Quality Control in Diagnostic Radiology MODELS A101 and A17 Model A101 is designed with acrylic sheath for use with phantoms that have a typical 13.1 mm cavity Fiducial markers identify center and both ends of the collecting volume providing easy setup in relation to the beam Excellent response uniformity with Model A101 over the central 10 cm of chamber length variation less than ± 3% Body tube and guard constructed of C552 Shonka air-equivalent conducting plastic, providing robust design and excellent conductivity eliminates fragility or flaking of painted conductive layers found in many chambers Model A17 provides an extremely flat response within ± 1.5% across its active length of 8 cm without polarity or perturbation effects Inherently waterproof, Model A17 is a unique CT ion chamber used for checking the consistency of the beam at various jaw widths Model A17 has an inherent Co-60 buildup cap built into its wall thickness Model A101 Model A17 * Ref: AAPM Report No. 74 Quality Control in Diagnostic Radiology, Medical Physics Publishing, 2002 Exradin CT Ion Chambers combine robust design with uniform energy response.

7 Shonka-Wyckoff Spherical Chambers For calibration laboratories, research applications, manufacturing and accelerator room scatter measurements MODELS A3, A4, A5, A6 Precise in air measurements from multiple fields without moving the chamber Obtain accurate measurements in any direction without absorption of the radiation by the body of the chamber Spherical volume chambers are easily centered for precise positioning resulting in accurate measurements Rugged design with integral rigid stem for easy, precise positioning Extended energy range through the use of equilibrium caps Constructed of C552 Shonka air-equivalent conducting plastic, providing robust design and excellent conductivity eliminates fragility or flaking of painted conductive layers found in many chambers Models A5 and A6 have a triaxial BNC connector mounted to the stem Model A3 Model A4 Model A5 Model A6 Shonka-Wyckoff Spherical Chambers are relied upon by standards laboratories throughout the world.

8 EXRADIN Ion Chambers Product Matrix FARMER-TYPE CHAMBERS MICROCHAMBERS MINIATURE SHONKA THIMBLE CHAMBERS MODEL A12 A12S 14 A14SL A16 1 A1SL 2 18 Collecting Volume 0.65 cc 0.25 cc cc cc cc cc cc 0.53 cc Centroid of Collecting Volume from exterior tip 12.9 mm 5.8 mm 2.0 mm 2.1 mm 1.8 mm 4.0 mm 4.1 mm 7.0 mm 4.9 m Centroid of Collecting Volume from exterior surface of window Outside Diameter of Shell Collecting Volume Inside Diameter of Shell Collecting Volume 7.1 mm 7.1 mm 6.0 mm 6.35 mm 3.4 mm 6.0 mm 6.35 mm 11.5 mm 6.9 m 6.1 mm 6.1 mm 4.0 mm 4.15 mm 2.5 mm 4.0 mm 4.15 mm 9.5 mm 7.9 m Window Collector Gap Shell Wall Thickness 0.5 mm 0.5 mm 1.0 mm 1.1 mm 0.5 mm 1.0 mm 1.1 mm 1.0 mm 1.0 m Collector Diameter 1.0 mm 1.0 mm 0.3 mm 0.3 mm 0.3 mm 1.0 mm 1.0 mm 4.6 mm 1.0 m Guard Ring Radial Widths Collector Length 21.6 mm 7.4 mm 1.52 mm 1.52 mm 1.27 mm 4.4 mm 4.4 mm 8.4 mm 6.4 m Window Material* Window Thickness Inner Axial Length of Collecting Volume 24 mm 10 mm 2.7 mm 2.7 mm 2.5 mm 5.8 mm 5.8 mm 10.9 mm 8.25 m Window or Support Rings, Collector and Guard Material* Shell, Collector and Guard Material* A A A, T A A A, T A A, P, T A Nominal Air Kerma Calibration Factor 44 Gy/µC 120 Gy/µC 3.2 Gy/nC 3.2 Gy/nC 3.5 Gy/nC 530 Gy/µC 530 Gy/µC 53 Gy/µC 230 G Nominal Leakage <10-15 amps <10-15 amps <10-15 amps <10-15 amps <10-15 amps <10-15 amps <10-15 amps <10-15 amps <10-15 Maximum Polarizing Voltage 1000 volts 1000 volts 1000 volts 1000 volts 1000 volts 1000 volts 1000 volts 1000 volts 1000 v Waterproof Yes Yes Yes Yes Yes Yes Yes Yes Ye Included Buildup Cap Co-60 Co-60 None None Co-60 None None None Co-6 * MATERIAL: A C552 Shonka air-equivalent plastic P D400 polystyrene-equivalent plastic T A150 Shonka tissue-equivalent plastic Nominal calibration factor for energies greater than 200 kev

9 CT ION CHAMBERS SHONKA-WYCKOFF SPHERICAL ION CHAMBERS PARALLEL PLATE ION CHAMBERS A3 A4 A5 A6 A TW Magna 1 cc Magna 3 cc cc 4.6 cc 1.91 cc 3.6 cc 30 cc 100 cc 800 cc 0.05 cc 0.62 cc 0.94 cc 1.0 cc 3.0 cc m 1.0 mm 2.0 mm 1.5 mm 3.96 mm 3.96 mm m 10.0 mm 12.7 mm 20.0 mm 39.2 mm 62.8 mm mm m 8.0 mm 6.1 mm 19.5 mm 38.2 mm 56.8 mm mm 2.0 mm 2.0 mm 3.0 mm 7.92 mm 7.92 mm m 1.0 mm 3.3 mm 0.25 mm 0.5 mm 3.0 mm 3.0 mm m 2.4 mm 2.4 mm 2.0 mm 4.0 mm 6.0 mm 11.6 mm 5.4 mm 20.0 mm 20.0 mm 12.7 mm 21.9 mm 4.3 mm 4.4 mm 4.4 mm 3.9 mm 7.6 mm m 100 mm 80 mm 13.3 mm 24.9 mm 37.3 mm 74.0 mm 3.86 mg/cm 2 Kapton 1.0 mm, A, P, or T 3.86 mg/cm 2 Kapton 3.86 mg/cm 2 Kapton 3.86 mg/cm 2 Kapton 0.03 mm 1.0 mm 0.03 mm 0.03 mm 0.03 mm m 120 mm 110 mm A A, P, T A, P, T A A A A A A A A y/µc 5.2 Gy/µC 1.2 R/nC 0.9 R/nC 0.09 R/nC 0.03R/nC 0.004R/nC 530 Gy/µC 48 Gy/µC 30 Gy/µC 180 Gy/µC 2.1 R/µC amps <10-15 amps <10-15 amps <10-15 amps <10-15 amps <10-15 amps <10-15 amps <10-15 amps <10-15 amps <10-15 amps <10-14 amps <10-14 amps olts 1000 volts 1000 volts 1000 volts 1000 volts 1000 volts 1000 volts 1000 volts 1000 volts 1000 volts 400 volts 400 volts s No Yes No No No No Yes, with included cap Yes Yes, with included cap No No 0 Acrylic sleeve Co-60 integral None None Co-60 integral Co-60 integral 1.0 mm acrylic, TG-51 Compliant None 1.0 mm acrylic, TG-51 Compliant None None

10 PH FAX Murphy Drive Middleton WI USA 2005 Standard Imaging, Inc (11.05)

CNMC 865 Easthagan Drive, Nashville, TN USA phone

CNMC 865 Easthagan Drive, Nashville, TN USA phone CNMC 865 Easthagan Drive, Nashville, TN 37217 USA BMI.v.04.2010 Electrometers CNMC Model 206 The CNMC Model 206 electrometer maintains the simplicity and ease of use of classic electrometers. Designed

More information

Preface. Med. Phys. 35(9), , Mechanical QA. Radiation Survey Mechanical tests Light radiation Table, Collimator, Gantry Jaws.

Preface. Med. Phys. 35(9), , Mechanical QA. Radiation Survey Mechanical tests Light radiation Table, Collimator, Gantry Jaws. AAPM-SAM-2012-Das (1) Beam Data Collection and Commissioning for Linear Accelerators: Technical Considerations and Recommendations Preface Indra J. Das, PhD, FAAPM, FACR, FASTRO Department of Radiation

More information

PROVEN TECHNOLOGY IMPROVED

PROVEN TECHNOLOGY IMPROVED PHANTOMS PROVEN TECHNOLOGY IMPROVED The DoseView 3D is a new 3-axis water phantom for performing comprehensive linear accelerator beam commissioning and quality assurance measurements quickly, accurately

More information

FAST, precise. qa software

FAST, precise. qa software qa software FAST, precise Software for accurate and independent verification of monitor units, dose, and overall validity of standard, IMRT, rotational or brachytherapy plans no film, no phantoms, no linac

More information

MAGNA A600 / A650 Ionization Chambers REF / User Manual

MAGNA A600 / A650 Ionization Chambers REF / User Manual MAGNA A600 / A650 Ionization Chambers REF 92600 / 92650 User Manual WWW..COM MAGNA A600 / A650 Ionization Chambers REF 92600 / 92650 STANDARD IMAGING INC. 3120 Deming Way Middleton, WI 53562-1461 Dec

More information

DAILY LINAC QA BEAM QA

DAILY LINAC QA BEAM QA BEAM QA DAILY LINAC QA The QA BeamChecker Plus allows for fast, reliable, and uncomplicated daily QA of Varian, Elekta, Siemens, and Accuray Treatment Machines. The QA BeamChecker Plus is specifically

More information

CBCT Equivalent Source Generation Using HVL and Beam Profile Measurements. Johnny Little PSM - Medical Physics Graduate Student University of Arizona

CBCT Equivalent Source Generation Using HVL and Beam Profile Measurements. Johnny Little PSM - Medical Physics Graduate Student University of Arizona CBCT Equivalent Source Generation Using HVL and Beam Profile Measurements. Johnny Little PSM - Medical Physics Graduate Student University of Arizona Introduction CBCT has become a routine procedure for

More information

ph fax Deming Way Middleton WI USA

ph fax Deming Way Middleton WI USA www.standardimaging.com 800-261-4446. ph 608-831-0025. fax 608-831-2202 3120 Deming Way Middleton WI 53562-1461 USA 2007 Standard Imaging, Inc. 1239-21 (03.07) beam qa LINAC AND TOMOTHERAPY QA The NEW

More information

IMSURE QA SOFTWARE FAST, PRECISE QA SOFTWARE

IMSURE QA SOFTWARE FAST, PRECISE QA SOFTWARE QA SOFTWARE FAST, PRECISE Software for accurate and independent verification of monitor units, dose, and overall validity of standard, IMRT, VMAT, SRS and brachytherapy plans no film, no phantoms, no linac

More information

A DOSIMETRIC MODEL FOR SMALL-FIELD ELECTRON RADIATION THERAPY A CREATIVE PROJECT (3 SEMESTER HOURS) SUBMITTED TO THE GRADUATE SCHOOL

A DOSIMETRIC MODEL FOR SMALL-FIELD ELECTRON RADIATION THERAPY A CREATIVE PROJECT (3 SEMESTER HOURS) SUBMITTED TO THE GRADUATE SCHOOL A DOSIMETRIC MODEL FOR SMALL-FIELD ELECTRON RADIATION THERAPY A CREATIVE PROJECT (3 SEMESTER HOURS) SUBMITTED TO THE GRADUATE SCHOOL IN PARTIAL FULFILLMENT OF THE REQUIREMENTS FOR THE DEGREE MASTER OF

More information

Monte Carlo Simulation for Neptun 10 PC Medical Linear Accelerator and Calculations of Electron Beam Parameters

Monte Carlo Simulation for Neptun 10 PC Medical Linear Accelerator and Calculations of Electron Beam Parameters Monte Carlo Simulation for Neptun 1 PC Medical Linear Accelerator and Calculations of Electron Beam Parameters M.T. Bahreyni Toossi a, M. Momen Nezhad b, S.M. Hashemi a a Medical Physics Research Center,

More information

C a t p h a n / T h e P h a n t o m L a b o r a t o r y

C a t p h a n / T h e P h a n t o m L a b o r a t o r y C a t p h a n 5 0 0 / 6 0 0 T h e P h a n t o m L a b o r a t o r y C a t p h a n 5 0 0 / 6 0 0 Internationally recognized for measuring the maximum obtainable performance of axial, spiral and multi-slice

More information

A SYSTEM OF DOSIMETRIC CALCULATIONS

A SYSTEM OF DOSIMETRIC CALCULATIONS A SYSTEM OF DOSIMETRIC CALCULATIONS INTRODUCTION Dose calculation based on PDD and TAR have Limitations The dependence of PDD on SSD Not suitable for isocentric techniques TAR and SAR does not depend on

More information

THE SIMULATION OF THE 4 MV VARIAN LINAC WITH EXPERIMENTAL VALIDATION

THE SIMULATION OF THE 4 MV VARIAN LINAC WITH EXPERIMENTAL VALIDATION 2007 International Nuclear Atlantic Conference - INAC 2007 Santos, SP, Brazil, September 30 to October 5, 2007 ASSOCIAÇÃO BRASILEIRA DE ENERGIA NUCLEAR - ABEN ISBN: 978-85-99141-02-1 THE SIMULATION OF

More information

CT vs. VolumeScope: image quality and dose comparison

CT vs. VolumeScope: image quality and dose comparison CT vs. VolumeScope: image quality and dose comparison V.N. Vasiliev *a, A.F. Gamaliy **b, M.Yu. Zaytsev b, K.V. Zaytseva ***b a Russian Sci. Center of Roentgenology & Radiology, 86, Profsoyuznaya, Moscow,

More information

3D SCANNER. 3D Scanning Comes Full Circle. Your Most Valuable QA and Dosimetry Tools

3D SCANNER. 3D Scanning Comes Full Circle. Your Most Valuable QA and Dosimetry Tools 3D SCANNER 3D Scanning Comes Full Circle Your Most Valuable QA and Dosimetry Tools BETTER OUTCOMES THROUGH TECHNOLOGY The 3D SCANNER is different by design. 3D SCANNER has been developed from the ground

More information

Design and performance characteristics of a Cone Beam CT system for Leksell Gamma Knife Icon

Design and performance characteristics of a Cone Beam CT system for Leksell Gamma Knife Icon Design and performance characteristics of a Cone Beam CT system for Leksell Gamma Knife Icon WHITE PAPER Introduction Introducing an image guidance system based on Cone Beam CT (CBCT) and a mask immobilization

More information

ImPACT. Information Leaflet No. 1: CT Scanner Acceptance Testing

ImPACT. Information Leaflet No. 1: CT Scanner Acceptance Testing ImPACT Information Leaflet No. 1: CT Scanner Acceptance Testing Version 1.02, 18/05/01 CONTENTS: 1. SCOPE OF LEAFLET 2. GENERAL PRINCIPLES OF ACCEPTANCE AND COMMISSIONING 2.1 PHANTOMS 2.2 EXPOSURE AND

More information

Monte Carlo methods in proton beam radiation therapy. Harald Paganetti

Monte Carlo methods in proton beam radiation therapy. Harald Paganetti Monte Carlo methods in proton beam radiation therapy Harald Paganetti Introduction: Proton Physics Electromagnetic energy loss of protons Distal distribution Dose [%] 120 100 80 60 40 p e p Ionization

More information

Machine and Physics Data Guide

Machine and Physics Data Guide WWW..COM Machine and Physics Data Guide STANDARD IMAGING, INC. 3120 Deming Way Middleton, WI 53562-1461 May / 2008 2008 Standard Imaging, Inc. TEL 800.261.4446 TEL 608.831.0025 FAX 608.831.2202 www.standardimaging.com

More information

Improvements in Monte Carlo simulation of large electron fields

Improvements in Monte Carlo simulation of large electron fields SLAC-PUB-12908 October 2007 Improvements in Monte Carlo simulation of large electron fields Bruce A Faddegon 1, Joseph Perl 2 and Makoto Asai 2 1 University of California San Francisco Comprehensive Cancer

More information

Assesing multileaf collimator effect on the build-up region using Monte Carlo method

Assesing multileaf collimator effect on the build-up region using Monte Carlo method Pol J Med Phys Eng. 2008;14(3):163-182. PL ISSN 1425-4689 doi: 10.2478/v10013-008-0014-0 website: http://www.pjmpe.waw.pl M. Zarza Moreno 1, 2, N. Teixeira 3, 4, A. P. Jesus 1, 2, G. Mora 1 Assesing multileaf

More information

Photon beam dose distributions in 2D

Photon beam dose distributions in 2D Photon beam dose distributions in 2D Sastry Vedam PhD DABR Introduction to Medical Physics III: Therapy Spring 2014 Acknowledgments! Narayan Sahoo PhD! Richard G Lane (Late) PhD 1 Overview! Evaluation

More information

Shielding factors for traditional safety glasses

Shielding factors for traditional safety glasses Shielding factors for traditional safety glasses Malcolm McEwen, Hong Shen and Ernesto Mainegra-Hing Ionizing Radiation Standards, National Research Council Canada Alan DuSautoy, Radiation and Health Sciences

More information

IMRT and VMAT Patient Specific QA Using 2D and 3D Detector Arrays

IMRT and VMAT Patient Specific QA Using 2D and 3D Detector Arrays IMRT and VMAT Patient Specific QA Using 2D and 3D Detector Arrays Sotiri Stathakis Outline Why IMRT/VMAT QA AAPM TG218 UPDATE Tolerance Limits and Methodologies for IMRT Verification QA Common sources

More information

Proton dose calculation algorithms and configuration data

Proton dose calculation algorithms and configuration data Proton dose calculation algorithms and configuration data Barbara Schaffner PTCOG 46 Educational workshop in Wanjie, 20. May 2007 VARIAN Medical Systems Agenda Broad beam algorithms Concept of pencil beam

More information

Clinical implementation of photon beam flatness measurements to verify beam quality

Clinical implementation of photon beam flatness measurements to verify beam quality JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, VOLUME 16, NUMBER 6, 2015 Clinical implementation of photon beam flatness measurements to verify beam quality Simon Goodall, a Nicholas Harding, Jake Simpson,

More information

Basics of treatment planning II

Basics of treatment planning II Basics of treatment planning II Sastry Vedam PhD DABR Introduction to Medical Physics III: Therapy Spring 2015 Dose calculation algorithms! Correction based! Model based 1 Dose calculation algorithms!

More information

A secondary monitor unit calculation algorithm using superposition of symmetric, open fields for IMRT plans

A secondary monitor unit calculation algorithm using superposition of symmetric, open fields for IMRT plans Louisiana State University LSU Digital Commons LSU Master's Theses Graduate School 2013 A secondary monitor unit calculation algorithm using superposition of symmetric, open fields for IMRT plans Adam

More information

EXTERNAL PHOTON BEAMS: PHYSICAL ASPECTS

EXTERNAL PHOTON BEAMS: PHYSICAL ASPECTS EXTERNAL PHOTON BEAMS: PHYSICAL ASPECTS E.B. PODGORSAK Department of Medical Physics, McGill University Health Centre, Montreal, Quebec, Canada 6.1. INTRODUCTION Radiotherapy procedures fall into two main

More information

ELECTRON DOSE KERNELS TO ACCOUNT FOR SECONDARY PARTICLE TRANSPORT IN DETERMINISTIC SIMULATIONS

ELECTRON DOSE KERNELS TO ACCOUNT FOR SECONDARY PARTICLE TRANSPORT IN DETERMINISTIC SIMULATIONS Computational Medical Physics Working Group Workshop II, Sep 30 Oct 3, 2007 University of Florida (UF), Gainesville, Florida USA on CD-ROM, American Nuclear Society, LaGrange Park, IL (2007) ELECTRON DOSE

More information

Analysis of Radiation Transport through Multileaf Collimators Using BEAMnrc Code

Analysis of Radiation Transport through Multileaf Collimators Using BEAMnrc Code American Journal of Biomedical Engineering 216, 6(4): 124-131 DOI: 1.5923/j.ajbe.21664.3 Analysis of Radiation Transport through Multileaf Collimators Using BEAMnrc Code Ankit Kajaria 1,*, Neeraj Sharma

More information

I. INTRODUCTION. Figure 1. Radiation room model at Dongnai General Hospital

I. INTRODUCTION. Figure 1. Radiation room model at Dongnai General Hospital International Journal of Computational Engineering Research Vol, 04 Issue, 4 Simulation of Photon and Electron dose distributions 5 code for the treatment area using the linear electron accelerator (LINAC)

More information

Comparison of absorbed dose distribution 10 MV photon beam on water phantom using Monte Carlo method and Analytical Anisotropic Algorithm

Comparison of absorbed dose distribution 10 MV photon beam on water phantom using Monte Carlo method and Analytical Anisotropic Algorithm Journal of Physics: Conference Series PAPER OPEN ACCESS Comparison of absorbed dose distribution 1 MV photon beam on water phantom using Monte Carlo method and Analytical Anisotropic Algorithm To cite

More information

VALIDATION OF IN-HOUSE DOSE CALCULATION SOFTWARE FOR SUPERFICIAL X-RAY THERAPY. A Thesis. Presented to the. Faculty of. San Diego State University

VALIDATION OF IN-HOUSE DOSE CALCULATION SOFTWARE FOR SUPERFICIAL X-RAY THERAPY. A Thesis. Presented to the. Faculty of. San Diego State University VALIDATION OF IN-HOUSE DOSE CALCULATION SOFTWARE FOR SUPERFICIAL X-RAY THERAPY A Thesis Presented to the Faculty of San Diego State University In Partial Fulfillment of the Requirements for the Degree

More information

Acceptance Testing and Commissioning of Monte Carlo Dose Calculation Systems. Bruce Curran University of Michigan Medical Center Ann Arbor, MI

Acceptance Testing and Commissioning of Monte Carlo Dose Calculation Systems. Bruce Curran University of Michigan Medical Center Ann Arbor, MI Acceptance Testing and Commissioning of Monte Carlo Dose Calculation Systems Bruce Curran University of Michigan Medical Center Ann Arbor, MI Disclosure Some of the work discussed in this talk was supported

More information

Development a simple point source model for Elekta SL-25 linear accelerator using MCNP4C Monte Carlo code

Development a simple point source model for Elekta SL-25 linear accelerator using MCNP4C Monte Carlo code Iran. J. Radiat. Res., 2006; 4 (1): 7-14 Development a simple point source model for Elekta SL-25 linear accelerator using MCNP4C Monte Carlo code. Mesbahi * Department of Medical Physics, Medical School,

More information

Dose Distributions. Purpose. Isodose distributions. To familiarize the resident with dose distributions and the factors that affect them

Dose Distributions. Purpose. Isodose distributions. To familiarize the resident with dose distributions and the factors that affect them Dose Distributions George Starkschall, Ph.D. Department of Radiation Physics U.T. M.D. Anderson Cancer Center Purpose To familiarize the resident with dose distributions and the factors that affect them

More information

Effects of the difference in tube voltage of the CT scanner on. dose calculation

Effects of the difference in tube voltage of the CT scanner on. dose calculation Effects of the difference in tube voltage of the CT scanner on dose calculation Dong Joo Rhee, Sung-woo Kim, Dong Hyeok Jeong Medical and Radiological Physics Laboratory, Dongnam Institute of Radiological

More information

Three-dimensional dosimetry of small fields

Three-dimensional dosimetry of small fields Three-dimensional of small fields Travis J. McCaw Medical Radiation Research Center Department of Medical Physics University of Wisconsin, Madison, WI NCCAAPM 2013 Fall Meeting 10 October 2013 Medical

More information

Verification measurements of an emc algorithm using a 2D ion chamber array

Verification measurements of an emc algorithm using a 2D ion chamber array JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, VOLUME 17, NUMBER 5, 2016 Verification measurements of an emc algorithm using a 2D ion chamber array Mark D. Wanklyn, 1a Ghirmay Kidane, 2 and Liz Crees 2 Medical

More information

PROVIDE A UNIFORM DOSE IN THE SMALL ANIMAL.

PROVIDE A UNIFORM DOSE IN THE SMALL ANIMAL. Considerations in the Use of the RS 2000 X ray Irradiator for Biological Research (Primarily Small Animal, tissue, and cells) and the fallacy of the High KV spectrum. The performance goal for a small animal

More information

An EGSnrc generated TG-43 dosimetry parameter database

An EGSnrc generated TG-43 dosimetry parameter database An EGSnrc generated TG-43 dosimetry parameter database Randle E. P. Taylor & D.W.O Rogers Carleton Laboratory for Radiotherapy Physics, Dept. of Physics, Carleton University Monte Carlo Workshop, May 30

More information

Interface Dosimetry for Electronic Brachytherapy Intracavitary Breast Balloon Applicators

Interface Dosimetry for Electronic Brachytherapy Intracavitary Breast Balloon Applicators Interface Dosimetry for Electronic Brachytherapy Intracavitary Breast Balloon Applicators J.J. Segala 1, G.A. Cardarelli 2, J.R. Hiatt 2, B.H. Curran 2, E.S. Sternick 2 1 Department of Physics, University

More information

DUAL energy X-ray radiography [1] can be used to separate

DUAL energy X-ray radiography [1] can be used to separate IEEE TRANSACTIONS ON NUCLEAR SCIENCE, VOL. 53, NO. 1, FEBRUARY 2006 133 A Scatter Correction Using Thickness Iteration in Dual-Energy Radiography S. K. Ahn, G. Cho, and H. Jeon Abstract In dual-energy

More information

Slide 1. Technical Aspects of Quality Control in Magnetic Resonance Imaging. Slide 2. Annual Compliance Testing. of MRI Systems.

Slide 1. Technical Aspects of Quality Control in Magnetic Resonance Imaging. Slide 2. Annual Compliance Testing. of MRI Systems. Slide 1 Technical Aspects of Quality Control in Magnetic Resonance Imaging Slide 2 Compliance Testing of MRI Systems, Ph.D. Department of Radiology Henry Ford Hospital, Detroit, MI Slide 3 Compliance Testing

More information

Basic Radiation Oncology Physics

Basic Radiation Oncology Physics Basic Radiation Oncology Physics T. Ganesh, Ph.D., DABR Chief Medical Physicist Fortis Memorial Research Institute Gurgaon Acknowledgment: I gratefully acknowledge the IAEA resources of teaching slides

More information

Multi-Purpose Body Phantom

Multi-Purpose Body Phantom Multi-Purpose Body Phantom Legal & Copyright Notice Information in this manual is subject to change without notice. Permission is granted to Owners of the to reproduce the Worksheets included in this manual

More information

Comparison of internal and external dose conversion factors using ICRP adult male and MEET Man voxel model phantoms.

Comparison of internal and external dose conversion factors using ICRP adult male and MEET Man voxel model phantoms. Comparison of internal and external dose conversion factors using ICRP adult male and MEET Man voxel model phantoms. D.Leone, A.Häußler Intitute for Nuclear Waste Disposal, Karlsruhe Institute for Technology,

More information

Monitor Unit (MU) Calculation

Monitor Unit (MU) Calculation Monitor Unit (MU) Calculation Timothy C. Zhu 1, Haibo Lin 1, and JiaJian Shen 2 1 University of Pennsylvania, Philadelphia, PA 2 Mayo Clinic, Phoenix, AZ Introduction Pencil-beam based dose/mu algorithms

More information

CHAPTER 3 MATERIALS AND METHODS

CHAPTER 3 MATERIALS AND METHODS CHAPTER 3 MATERIALS AND METHODS The thesis work has been carried out to develop the indigenous 3D Radiation Field Analyzer, dosimetric and commissioning of FFF beam and clinical use of FFF beam for complex

More information

Measurement of depth-dose of linear accelerator and simulation by use of Geant4 computer code

Measurement of depth-dose of linear accelerator and simulation by use of Geant4 computer code reports of practical oncology and radiotherapy 1 5 (2 0 1 0) 64 68 available at www.sciencedirect.com journal homepage: http://www.rpor.eu/ Original article Measurement of depth-dose of linear accelerator

More information

Investigation of tilted dose kernels for portal dose prediction in a-si electronic portal imagers

Investigation of tilted dose kernels for portal dose prediction in a-si electronic portal imagers Investigation of tilted dose kernels for portal dose prediction in a-si electronic portal imagers Krista Chytyk MSc student Supervisor: Dr. Boyd McCurdy Introduction The objective of cancer radiotherapy

More information

Hidenobu Tachibana The Cancer Institute Hospital of JFCR, Radiology Dept. The Cancer Institute of JFCR, Physics Dept.

Hidenobu Tachibana The Cancer Institute Hospital of JFCR, Radiology Dept. The Cancer Institute of JFCR, Physics Dept. 2-D D Dose-CT Mapping in Geant4 Hidenobu Tachibana The Cancer Institute Hospital of JFCR, Radiology Dept. The Cancer Institute of JFCR, Physics Dept. Table of Contents Background & Purpose Materials Methods

More information

Qalitätssicherung an Multileafkollimatoren. Dr. Lutz Müller Würzburg jan 2004

Qalitätssicherung an Multileafkollimatoren. Dr. Lutz Müller Würzburg jan 2004 Qalitätssicherung an Multileafkollimatoren Dr. Lutz Müller Würzburg jan 2004 IMRT Verification - present Target Volume Constraints Inverse Planning Algorithm Fluence Map Leaf Sequencer Leaf & Gantry sequence

More information

Determination of primary electron beam parameters in a Siemens Primus Linac using Monte Carlo simulation

Determination of primary electron beam parameters in a Siemens Primus Linac using Monte Carlo simulation Determination of primary electron beam parameters in a Siemens Primus Linac using Monte Carlo simulation Danial Seifi Makrani 1, Hadi Hasanzadeh 2*, Tayyeb Allahverdi Pourfallah 3, Arash Ghasemi 4, Majid

More information

Comparison of Two Phantoms for End-to-End SRS/SBRT Testing. Vikren Sarkar, Ph.D. Associate Professor University of Utah Huntsman Cancer Center

Comparison of Two Phantoms for End-to-End SRS/SBRT Testing. Vikren Sarkar, Ph.D. Associate Professor University of Utah Huntsman Cancer Center Comparison of Two Phantoms for End-to-End SRS/SBRT Testing Vikren Sarkar, Ph.D. Associate Professor University of Utah Huntsman Cancer Center Disclosure Travel and Speaker Honorarium from Sun Nuclear Corp.

More information

Optimization of CT Simulation Imaging. Ingrid Reiser Dept. of Radiology The University of Chicago

Optimization of CT Simulation Imaging. Ingrid Reiser Dept. of Radiology The University of Chicago Optimization of CT Simulation Imaging Ingrid Reiser Dept. of Radiology The University of Chicago Optimization of CT imaging Goal: Achieve image quality that allows to perform the task at hand (diagnostic

More information

Monte Carlo Methods for Accelerator Simulation and Photon Beam Modeling

Monte Carlo Methods for Accelerator Simulation and Photon Beam Modeling Monte Carlo Methods for Accelerator Simulation and Photon Beam Modeling AAPM Summer School 2006 Windsor, ON Part I Daryoush Sheikh-Bagheri, PhD Allegheny General Hospital Pittsburgh, PA A sample of work

More information

ISO ISO ISO OHSAS ISO

ISO ISO ISO OHSAS ISO ISO 9001 ISO 13485 ISO 14001 OHSAS 18001 ISO 27001 Pro-NM Performance 08-101 - standard version 08-103 - version with the PET Lid Phantom for NM and PET systems performance evaluation (collimator, artifacts,

More information

Investigation of photon beam output factors for conformal radiation therapy Monte Carlo simulations and measurements

Investigation of photon beam output factors for conformal radiation therapy Monte Carlo simulations and measurements INSTITUTE OF PHYSICSPUBLISHING Phys. Med. Biol. 47 (2002) N133 N143 PHYSICS INMEDICINE AND BIOLOGY PII: S0031-9155(02)32395-9 NOTE Investigation of photon beam output factors for conformal radiation therapy

More information

MCNP4C3-BASED SIMULATION OF A MEDICAL LINEAR ACCELERATOR

MCNP4C3-BASED SIMULATION OF A MEDICAL LINEAR ACCELERATOR Computational Medical Physics Working Group Workshop II, Sep 3 Oct 3, 7 University of Florida (UF), Gainesville, Florida USA on CD-ROM, American Nuclear Society, LaGrange Park, IL (7) MCNP4C3-BASED SIMULATION

More information

Acknowledgments. Ping Xia, Ph.D., UCSF. Pam Akazawa, CMD, UCSF. Cynthia Chuang, Ph.D., UCSF

Acknowledgments. Ping Xia, Ph.D., UCSF. Pam Akazawa, CMD, UCSF. Cynthia Chuang, Ph.D., UCSF Page 1 Quality Assurance of IMRT Delivery Systems - Siemens Lynn J. Verhey, Ph.D. Professor and Vice-Chair UCSF Dept. of Radiation Oncology AAPM 22 Annual Meeting, Montreal Acknowledgments Ping Xia, Ph.D.,

More information

Disclosure. Outline. Acknowledgments. Ping Xia, Ph.D., Page 1. LINAC and MLC QA for IMRT. Received research support from Siemens Medical Solutions

Disclosure. Outline. Acknowledgments. Ping Xia, Ph.D., Page 1. LINAC and MLC QA for IMRT. Received research support from Siemens Medical Solutions LINAC and MLC QA for IMRT Ping Xia, Ph.D., Department of Radiation Oncology Disclosure Received research support from Siemens Medical Solutions University of California San Francisco Therapy Series (SAM)

More information

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD INTERNATIONAL STANDARD IEC 60601-2-44 2001 AMENDMENT 1 2002-09 Amendment 1 Medical electrical equipment Part 2-44: Particular requirements for the safety of X-ray equipment for computed tomography Amendement

More information

Spiral CT. Protocol Optimization & Quality Assurance. Ge Wang, Ph.D. Department of Radiology University of Iowa Iowa City, Iowa 52242, USA

Spiral CT. Protocol Optimization & Quality Assurance. Ge Wang, Ph.D. Department of Radiology University of Iowa Iowa City, Iowa 52242, USA Spiral CT Protocol Optimization & Quality Assurance Ge Wang, Ph.D. Department of Radiology University of Iowa Iowa City, Iowa 52242, USA Spiral CT Protocol Optimization & Quality Assurance Protocol optimization

More information

Validation of GEANT4 for Accurate Modeling of 111 In SPECT Acquisition

Validation of GEANT4 for Accurate Modeling of 111 In SPECT Acquisition Validation of GEANT4 for Accurate Modeling of 111 In SPECT Acquisition Bernd Schweizer, Andreas Goedicke Philips Technology Research Laboratories, Aachen, Germany bernd.schweizer@philips.com Abstract.

More information

Michael Speiser, Ph.D.

Michael Speiser, Ph.D. IMPROVED CT-BASED VOXEL PHANTOM GENERATION FOR MCNP MONTE CARLO Michael Speiser, Ph.D. Department of Radiation Oncology UT Southwestern Medical Center Dallas, TX September 1 st, 2012 CMPWG Workshop Medical

More information

Electron Dose Kernels (EDK) for Secondary Particle Transport in Deterministic Simulations

Electron Dose Kernels (EDK) for Secondary Particle Transport in Deterministic Simulations Electron Dose Kernels (EDK) for Secondary Particle Transport in Deterministic Simulations A. Al-Basheer, G. Sjoden, M. Ghita Computational Medical Physics Team Nuclear & Radiological Engineering University

More information

New Technology in Radiation Oncology. James E. Gaiser, Ph.D. DABR Physics and Computer Planning Charlotte, NC

New Technology in Radiation Oncology. James E. Gaiser, Ph.D. DABR Physics and Computer Planning Charlotte, NC New Technology in Radiation Oncology James E. Gaiser, Ph.D. DABR Physics and Computer Planning Charlotte, NC Technology s s everywhere From the imaging chain To the planning system To the linac To QA..it..it

More information

3D Scanning Comes Full Circle

3D Scanning Comes Full Circle 3D SCANNER TM 3D Scanning Comes Full Circle Relative 3D Dosimetry offering the easiest setup, most objectivity, and best consistency available Cross-Plane Advanced Design Ring and diameter drive mechanism

More information

Air Kerma Strength Measurements and Monte Carlo based Dosimetric Characterization of a directional Pd 103 planar source array.

Air Kerma Strength Measurements and Monte Carlo based Dosimetric Characterization of a directional Pd 103 planar source array. Air Kerma Strength Measurements and Monte Carlo based Dosimetric Characterization of a directional Pd 103 planar source array. MANIK AIMA UWMRRC, MADISON 2014 NCAAPM Autumn Meeting October 24 th, 2014

More information

A Customized Bolus Produced Using a 3-Dimensional Printer for Radiotherapy

A Customized Bolus Produced Using a 3-Dimensional Printer for Radiotherapy A Customized Bolus Produced Using a 3-Dimensional Printer for Radiotherapy Shin-Wook Kim, Hun-Joo Shin, Chul Seung Kay, Seok Hyun Son* Radiation Oncology, Incheon St. Mary s Hospital, College of Medicine,

More information

VCU Radiation Oncology

VCU Radiation Oncology Semi-empirical Dose-Calculation Models in Brachytherapy AAPM 2005 Summer School 25 July 2004 Jeffrey F. Williamson, Ph.D. VCU Radiation Oncology Virginia Commonwealth University Semi-Empirical Dose-Calculation

More information

On compensator design for photon beam intensity-modulated conformal therapy

On compensator design for photon beam intensity-modulated conformal therapy On compensator design for photon beam intensity-modulated conformal therapy Steve B. Jiang a) and Komanduri M. Ayyangar Department of Radiation Therapy, Medical College of Ohio, 3000 Arlington Avenue,

More information

Comparison Study of Monte Carlo Simulations and Measurements of Relative Output Factors of 6 MV Photon Beam

Comparison Study of Monte Carlo Simulations and Measurements of Relative Output Factors of 6 MV Photon Beam Comparison Study of Monte Carlo Simulations and Measurements of Relative Output Factors of 6 MV Photon Beam Nakorn Phaisangittisakul 1*, Wanchaloem Saprangsi 2, Chirapha Tannanonta 2 and Sivalee Suriyapee

More information

NEW METHOD OF COLLECTING OUTPUT FACTORS FOR COMMISSIONING LINEAR ACCELERATORS WITH SPECIAL EMPHASIS

NEW METHOD OF COLLECTING OUTPUT FACTORS FOR COMMISSIONING LINEAR ACCELERATORS WITH SPECIAL EMPHASIS NEW METHOD OF COLLECTING OUTPUT FACTORS FOR COMMISSIONING LINEAR ACCELERATORS WITH SPECIAL EMPHASIS ON SMALL FIELDS AND INTENSITY MODULATED RADIATION THERAPY by Cindy D. Smith A Thesis Submitted to the

More information

Artifact Mitigation in High Energy CT via Monte Carlo Simulation

Artifact Mitigation in High Energy CT via Monte Carlo Simulation PIERS ONLINE, VOL. 7, NO. 8, 11 791 Artifact Mitigation in High Energy CT via Monte Carlo Simulation Xuemin Jin and Robert Y. Levine Spectral Sciences, Inc., USA Abstract The high energy (< 15 MeV) incident

More information

Indrin Chetty Henry Ford Hospital Detroit, MI. AAPM Annual Meeting Houston 7:30-8:25 Mon 08/07/28 1/30

Indrin Chetty Henry Ford Hospital Detroit, MI.   AAPM Annual Meeting Houston 7:30-8:25 Mon 08/07/28 1/30 Review of TG105: Issues associated with clinical implementation of Monte Carlo-based photon and electron external beam treatment planning D. W. O. Rogers, Carleton Laboratory for Radiotherapy Physics,

More information

THE WIRELESS PHANTOM PERFORM ACCURATE PATIENT QA IN LESS TIME THAN EVER!

THE WIRELESS PHANTOM PERFORM ACCURATE PATIENT QA IN LESS TIME THAN EVER! THE WIRELESS PHANTOM PERFORM ACCURATE PATIENT QA IN LESS TIME THAN EVER! Confidence in complex treatments Modern radiation therapy uses complex plans with techniques such as IMRT, VMAT and Tomotherapy.

More information

MRI-LINAC Dynamic Phantom

MRI-LINAC Dynamic Phantom MRI-LINAC Dynamic Phantom Model 008M IMAGE ACQUISITION TREATMENT PLANNING DOSE DELIVERY Strict QA procedures for the imaging, planning and delivery of radiotherapy using respiratory management devices

More information

MapCHECK 2 & 3DVH. The Gold Standard for 2D Arrays

MapCHECK 2 & 3DVH. The Gold Standard for 2D Arrays MapCHECK 2 & 3DVH The Gold Standard for 2D Arrays Your Most Valuable QA and Dosimetry Tools THE GOLD STANDARD FOR 2D ARRAYS The MapCHECK 2 is the world s most selected independent 2D measurement array.

More information

Implementation of the EGSnrc / BEAMnrc Monte Carlo code - Application to medical accelerator SATURNE43

Implementation of the EGSnrc / BEAMnrc Monte Carlo code - Application to medical accelerator SATURNE43 International Journal of Innovation and Applied Studies ISSN 2028-9324 Vol. 6 No. 3 July 2014, pp. 635-641 2014 Innovative Space of Scientific Research Journals http://www.ijias.issr-journals.org/ Implementation

More information

The team. Disclosures. Ultrasound Guidance During Radiation Delivery: Confronting the Treatment Interference Challenge.

The team. Disclosures. Ultrasound Guidance During Radiation Delivery: Confronting the Treatment Interference Challenge. Ultrasound Guidance During Radiation Delivery: Confronting the Treatment Interference Challenge Dimitre Hristov Radiation Oncology Stanford University The team Renhui Gong 1 Magdalena Bazalova-Carter 1

More information

Dynalog data tool for IMRT plan verification

Dynalog data tool for IMRT plan verification Dynalog data tool for IMRT plan verification Poster No.: R-0051 Congress: 2014 CSM Type: Scientific Exhibit Authors: V. Sashin; FOOTSCRAY/AU Keywords: Computer applications, Radiation physics, Experimental,

More information

Ch. 4 Physical Principles of CT

Ch. 4 Physical Principles of CT Ch. 4 Physical Principles of CT CLRS 408: Intro to CT Department of Radiation Sciences Review: Why CT? Solution for radiography/tomography limitations Superimposition of structures Distinguishing between

More information

Raising the Bar in IMRT QA

Raising the Bar in IMRT QA MapCHECK 2TM Raising the Bar in IMRT QA The leader in quick and precise measurement of modulated radiotherapy beams Benefits Proven solution for film-less rotational delivery and IMRT QA - More than 1500

More information

MapCHECK 2 & 3DVH The Gold Standard for 2D Arrays

MapCHECK 2 & 3DVH The Gold Standard for 2D Arrays MapCHECK 2 & 3DVH The Gold Standard for 2D Arrays Your Most Valuable QA and Dosimetry Tools THE GOLD STANDARD FOR 2D ARRAYS The MapCHECK 2 is the world s most selected independent 2D measurement array.

More information

THESIS NEUTRON PRODUCTION AND TRANSPORT AT A MEDICAL LINEAR ACCELERATOR. Submitted by. Amber Allardice

THESIS NEUTRON PRODUCTION AND TRANSPORT AT A MEDICAL LINEAR ACCELERATOR. Submitted by. Amber Allardice THESIS NEUTRON PRODUCTION AND TRANSPORT AT A MEDICAL LINEAR ACCELERATOR Submitted by Amber Allardice Department of Environmental and Radiological Health Sciences In partial fulfillment of the requirements

More information

Use of Monte Carlo modelling in radiotherapy linac design. David Roberts, PhD Senior Physicist Elekta

Use of Monte Carlo modelling in radiotherapy linac design. David Roberts, PhD Senior Physicist Elekta Use of Monte Carlo modelling in radiotherapy linac design David Roberts, PhD Senior Physicist Elekta Contents Overview of Elekta What we do Where we use Monte Carlo Codes and resources Example : Agility

More information

DETERMINISTIC 3D RADIATION TRANSPORT SIMULATION FOR DOSE DISTRIBUTION AND ORGAN DOSE EVALUATION IN DIAGNOSTIC CT

DETERMINISTIC 3D RADIATION TRANSPORT SIMULATION FOR DOSE DISTRIBUTION AND ORGAN DOSE EVALUATION IN DIAGNOSTIC CT DETERMINISTIC 3D RADIATION TRANSPORT SIMULATION FOR DOSE DISTRIBUTION AND ORGAN DOSE EVALUATION IN DIAGNOSTIC CT Monica Ghita,, Glenn Sjoden, Manuel Arreola, Ahmad Al-Basheer Basheer, Choonsik Lee, Wesley

More information

An Investigation of a Model of Percentage Depth Dose for Irregularly Shaped Fields

An Investigation of a Model of Percentage Depth Dose for Irregularly Shaped Fields Int. J. Cancer (Radiat. Oncol. Invest): 96, 140 145 (2001) 2001 Wiley-Liss, Inc. Publication of the International Union Against Cancer An Investigation of a Model of Percentage Depth Dose for Irregularly

More information

Applying Hounsfield unit density calibration in SkyScan CT-analyser

Applying Hounsfield unit density calibration in SkyScan CT-analyser 1 Bruker-microCT Method note Applying Hounsfield unit density calibration in SkyScan CT-analyser Hounsfield units (HU) are a standard unit of x-ray CT density, in which air and water are ascribed values

More information

Room scatter effects in Total Skin Electron Irradiation: Monte Carlo simulation study

Room scatter effects in Total Skin Electron Irradiation: Monte Carlo simulation study Received: 9 November 2016 Revised: 9 November 2016 Accepted: 28 November 2016 DOI: 10.1002/acm2.12039 RADIATION ONCOLOGY PHYSICS Room scatter effects in Total Skin Electron Irradiation: Monte Carlo simulation

More information

The IORT Treatment Planning System. radiance. GMV, 2012 Property of GMV All rights reserved

The IORT Treatment Planning System. radiance. GMV, 2012 Property of GMV All rights reserved The IORT Treatment Planning System radiance Property of GMV All rights reserved WHY RADIANCE? JUSTIFICATION Property of GMV All rights reserved ADVANTAGES OF IORT PRECISION: RT guided by direct vision.

More information

CHAPTER 2 MEDICAL IMAGING WITH NON-IONIZING RADIATION

CHAPTER 2 MEDICAL IMAGING WITH NON-IONIZING RADIATION CHAPTER 2 MEDICAL IMAGING WITH NON-IONIZING RADIATION 1 Ultrasound Imaging 1.1 Ultrasound Production and Detection Ultrasound is frequency vibration. To produce and detect ultrasound, we use crystals which

More information

JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, VOLUME 7, NUMBER 3, SUMMER 2006

JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, VOLUME 7, NUMBER 3, SUMMER 2006 JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, VOLUME 7, NUMBER 3, SUMMER 2006 Evaluation of dosimetric effect of leaf position in a radiation field of an 80-leaf multileaf collimator fitted to the LINAC

More information

Physics 210 Medical Physics Midterm Exam Fall 2012 October 12, 2012

Physics 210 Medical Physics Midterm Exam Fall 2012 October 12, 2012 Physics 210 Medical Physics Midterm Exam Fall 2012 October 12, 2012 Name Problem 1 /32 Problem 2 /32 Problem 3 /24 Total /88 I affirm that I have carried out my academic endeavors with full academic honesty.

More information

Nuclear Associates and

Nuclear Associates and Nuclear Associates 84-317 and 84-317-7000 Multipurpose Tissue/Cyst Ultrasound Phantoms Users Manual February 2005 Manual No. 84-317-1 Rev. 2 2004, 2005 Fluke Corporation, All rights reserved. Printed in

More information

Influence of electron density spatial distribution and X-ray beam quality during CT simulation on dose calculation accuracy

Influence of electron density spatial distribution and X-ray beam quality during CT simulation on dose calculation accuracy JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, VOLUME 12, NUMBER 3, summer 2011 Influence of electron density spatial distribution and X-ray beam quality during CT simulation on dose calculation accuracy

More information