Quality Enclosures. Service Excellence.
|
|
- Willis Alvin Pearson
- 6 years ago
- Views:
Transcription
1 Wireway & Trough 318
2 Wireway & Trough 1485 Series Lay-In Wireway - NEM Series Wiring Trough - NEM Series Pull Through Wireway - NEM Lay In Wireway - NEM Wireway & Trough 319
3 1485 Series Lay-In Wireway - NEM 12 pplication Designed to enclose and protect electrical wiring from dirt, dust, oil and water. ll sections and fittings are completely open on each side to allow wires and cables to be placed into the wireway without pulling through. Standards UL 870 Type 1 (unless marked1) CS Type 1 (unless marked1) Complies with NEM Type 12 JIC EMP JIC EGP IEC 60529, IP54 Construction odies and covers are formed from 14-gauge steel with 10 gauge steel flanges. 12 x 6 size has a 12 gauge steel body with a 14-gauge cover. Smooth continuously welded seams. Interior surfaces are smooth to prevent wire damage during installation. utt hinged cover is secured with easily operated quick release clamps. Oil resistant gaskets are permanently secured. Solid oil resistant gaskets are used between flanges when sections and fittings are bolted together. One gasket kit, complete with hardware is provided with each straight section or fitting. Sealing plate is supplied. Flange junctions are sealed with gasket sealing plates, which are put in place after wiring is completed. One is supplied with all straight sections and most fittings; see table for exact number. Finish s and components are finished in NSI 61 gray powder coating. Notes When joining a wireway section or fitting to an enclosure be sure to order a box connector. When joining two wireway sections, or joining a wireway section to a fitting, a flat sealing plate is required at each junction; necessary kits are supplied with each section and fitting. See table, extra kits may be ordered if necessary. When joining a lay-in wireway section or fitting to a closure plate, a box connector, or cut-off fitting, an angle sealing plate is required at each junction. Necessary kits are supplied with each section and fitting - see table. Extra kits, although not normally required, are necessary when joining lay-in wireway to a non-lay-in section or fitting section. 320
4 1485 Series Lay-In Wireway - NEM 12 Description Sealing Plates 2.5 x x 4 6 x 6 8 x 8 12 x 6 Supplied 6" 1 Flat C6 1485D6 1485E6 1485F6 12" 1 Flat C D E F12 24" 1 Flat C D E F24 36" 1 Flat C D E F36 48" 1 Flat C D E F48 60" 1 Flat C D E F60 120" 1 Flat C D E F120 60" Long Partition (arrier) 1487C D E D60 1 1" Nipple 1 Flat 1485M1 1485CM1 1485DM1 2" Nipple 1 Flat 1485M2 1485CM2 1485DM2 3" Nipple 1 Flat 1485M3 1485CM3 1485DM3 ox Entry Swivel Nipple 1 ngle 1485V1 1485CV1 1485DV1 1485EV1 Standard Swivel Nipple 2 ngle 1485V2 1485CV2 1485DV2 1485EV2 12" Transposition Clockwise 1 Flat 1485Z CZ DZ EZ12 12" Transposition Counter-Clockwise 1 Flat 1485ZC CZC DZC EZC12 Flexible Fitting None 1485FF 1485CFF 1485DFF 1485EFF djustable Fitting 1 Spec. 1485X CX DX EX FX 1 Cut-Off Fitting Lay-In 1 Flat 1485W CW DW EW FW1 1 Cut-Off Fitting Non Lay-In 1 ngle 1485W CW DW EW FW Elbow, Top Opening 1 Flat 14859N 1485C9N 1485D9N 1485E9N 1485F9N 90 Elbow, Inside Opening 1 Flat 14859P 1485C9P 1485D9P 1485E9P 1485F9P 90 Elbow, Outside Opening 1 Flat 14859Q 1485C9Q 1485D9Q 1485E9Q 1485F9Q 45 Elbow, Top Opening 1 Flat 14854N 1485C4N 1485D4N 1485E4N 1485F4N 45 Elbow, Inside Opening 1 Flat 14854P 1485C4P 1485D4P 1485E4P 45 Elbow, Outside Opening 1 Flat 14854Q 1485C4Q 1485D4Q 1485E4Q Tee Fitting, Top Opening 2 Flat 1485TN 1485CTN 1485DTN 1485ETN 1485FTN Tee Fitting, Outside & Top Opening 2 Flat 1485TQ 1485CTQ 1485DTQ 1485ETQ Cross Fitting 3 Flat 1485Y 1485CY 1485DY 1485EY 1485FY Reducer 4 x 4 to 2.5 x 2.5 None 1485CRE Reducer 6 x 6 to 4 x 4 None 1485DRE Reducer 8 x 8 to 6 x 6 None 1485ERE Reducer 12 x 6 to 4 x 4 None 1485FREC Reducer 12 x 6 to 6 x 6 None 1485FRED Junction ox 1 Flat 1485J 1485CJ 1485DJ 1485EJ ox Connector 1 ngle 1485K CK DK EK FK 1 Drop Hanger None 1485L CL DL EL1 1 racket Hanger None 1485L CL DL EL2 1 Cover Plate 1 ngle 1485H CH DH EH FH 2 Snap On Flat Sealing Plate None 1485SM CSM DSM ESM FSM 2 ngle Sealing Plate None 1485S CS DS ES FS9 2 1 Does not meet CS or UL requirements 2 Maintains ratings on CS and UL approved wireway 321
5 1485 Series Lay-In Wireway - NEM 12 ll unmarked diameters are 0.28 ll unmarked radii are
6 1485 Series Lay-In Wireway - NEM 12 Snap On Flat Sealing Plate 1485SM 2.5 x CSM 4 x DSM 6 x ESM 8 x FSM 12 x 6 Maintains ratings on CS and UL approved wireway ngle Sealing Plate 1485S9 2.5 x CS9 4 x DS9 6 x ES9 8 x FS9 12 x 6 Maintains ratings on CS and UL approved wireway Typical Straight C=6" C=12" C=24" C=36" Partition (arrier) Kit Divides wireway into two or more compartments. arriers are fastened to wireway sections with screws. X 1487C60 4 x D60 6 x E60 8 x D60 12 x Does not meet CS or UL requirements C=48" C=60" C=120" x C6 1485C C C C C C120 4 x D6 1485D D D D D D120 6 x E6 1485E E E E E E120 8 x F6 1485F F F F F F x 6 ox Entry or Standard Swivel Nipple ox Entry Swivel Nipple Standard Swivel Nipple 1485V V x CV CV2 2 4 x DV DV2 2 6 x EV EV2 2 8 x 8 1 One angle sealing plate included Two angle sealing plates included 323
7 1485 Series Lay-In Wireway - NEM 12 Flexible Fitting llows for easy alignment of sections or fittings Metal flanges Flexible synthetic "bellows" middle section 1485FF CFF DFF EFF 8 8 Cut-Off Fitting (Lay-In) ody comes in two pieces. Cut-off one piece, shorten cover, and weld together. Includes angle sealing plate. djustable Fitting llows on site length adjustment of 2" to 7" 1485X 2.5 x CX 4 x DX 6 x EX 8 x FX 12 x 6 One special sealing plate included Does not meet CS or UL requirements Cut-Off Fitting (Non Lay-in) For lengths up to 12. Cut off body and weld on flange. Cross Fitting H M 1485Y 2.5 x CY 4 x DY 6 x EY 8 x FY 12 x Three flat sealing plates included Typical Nipple Lay-in nipples come with a special sealing plate which cannot be used adjacent to swivel nipples (use 1487 Series nipples) 1485W1 2.5 x CW1 4 x DW1 6 x EW1 8 x FW1 12 x 6 Does not meet CS or UL requirements 1485W2 2.5 x CW2 4 x DW2 6 x EW2 8 x FW2 12 x 6 One angle sealing plate included Does not meet CS or UL requirements 1" Nipple 2" Nipple 3" Nipple 1485M1 1485M2 1485M3 2.5 x CM1 1485CM2 1485CM3 4 x DM1 1485DM2 1485DM3 6 x 6 324
8 1485 Series Lay-In Wireway - NEM Elbow Top Opening K 14854N 2.5 x C4N 4 x D4N 6 x E4N 8 x F4N 12 x Elbow Top Opening 45 Elbow Inside Opening Y 14854P 2.5 x C4P 4 x D4P 6 x E4P 8 x Elbow Inside Opening 45 Elbow Outside Opening Z 14854Q 2.5 x C4Q 4 x D4Q 6 x E4Q 8 x Elbow Outside Opening M 14859N 2.5 x C9N 4 x D9N 6 x E9N 8 x F9N 12 x J 14859P 2.5 x C9P 4 x D9P 6 x E9P 8 x F9P 12 x J 14859Q 2.5 x C9Q 4 x D9Q 6 x E9Q 8 x F9Q 12 x
9 1485 Series Lay-In Wireway - NEM 12 Clockwise Tee Fitting Top Opening H M 1485TN 2.5 x CTN 4 x DTN 6 x ETN 8 x FTN 12 x Two flat sealing plates included Reducers Reduces from to 1485CRE 4 x x DRE 6 x 6 4 x ERE 8 x 8 6 x FREC 12 x 6 4 x FRED 12 x 6 6 x 6 Tee Fitting Outside and Top Opening H M 1485TQ 2.5 x CTQ 4 x DTQ 6 x ETQ 8 x Two flat sealing plates included ox Connector Use inside box when entering with "Lay-In" Wireway. E G 1485K 2.5 x CK 4 x DK 6 x EK 8 x FK 12 x One angled sealing plate included Counter-Clockwise 12" Transposition s Clockwise & Counter-Clockwise Used to rotate the open side of a wireway run by 90 and maintain the lay-in feature Clockwise Counter- Clockwise 1485Z ZC x CZ CZC12 4 x DZ DZC12 6 x EZ EZC12 8 x 8 326
10 1485 Series Lay-In Wireway - NEM 12 Drop Hanger R W 1485L1 2.5 x CL1 4 x DL1 6 x EL1 8 x Does not meet CS or UL requirements racket Hanger R W 1485L2 2.5 x CL2 4 x DL2 6 x EL2 8 x Does not meet CS or UL requirements Junction ox Includes inner panel. Cover Plate E G 1485H 2.5 x CH 4 x DH 6 x EH 8 x FH 12 x One angled sealing plate included Maintains ratings on CS and UL approved wireway N P Panel 1485J 2.5 x x CJ 4 x x DJ 6 x x EJ 8 x x
11 1486 Series Wiring Trough - NEM 12 Wireway & Trough Wiring Trough pplication Designed to enclose and protect multiple wiring junctions from dirt, dust, oil and water. Standards UL 870 Type 1 CS Type 1 Complies with NEM Type 12 JIC EGP JIC EMP IEC 60529, IP54 Construction Formed 14 gauge steel. Smooth continuously welded seams. utt hinged cover is secured with easily operated screw clamps. Oil resistant gaskets are permanently secured. 12 gauge external mounting feet are welded to the back. Finish Troughs and covers are finished in NSI 61 gray powder coating. 328
12 1486 Series Wiring Trough - NEM 12 Length Cover Ship Wt. C D E F G H J lbs C C C C C C C C D D D D D D D D Wireway & Trough Wiring Trough 329
13 1487 Series Pull Through Wireway - NEM 12 Wireway & Trough Pull Through Wireway pplication Designed to enclose and protect electrical wiring from dirt, dust, oil and water. Ideal for connecting machines to control panels or power sources. Standards UL 870 Type 1 (unless marked 1 ) CS Type 1 (unless marked 1 ) Complies with NEM Type 12 JIC EMP JIC EGP IEC 60529, IP54 Construction odies and covers are formed from 14 gauge steel with 10 gauge steel flanges. Smooth continuously welded seams. Interior surfaces are smooth to prevent wire damage during installation. utt hinged covers are secured with easily operated screw clamps. Oil resistant gaskets are permanently secured. Solid oil resistant gaskets are used between flanges when sections and fittings are bolted together. One gasket kit, complete with hardware is provided with each straight section or fitting. Finish s and fittings are finished in NSI 61 gray. 330
14 1487 Series Pull Through Wireway - NEM 12 Description 2.5 x x 4 6 x 6 8 x 8 12" C D E12 24" C D E24 36" C D E36 48" C D E48 60" C D E60 120" C D E120 60" Long Partition (arrier) 1487C D E60 1 1" Nipple 1487M1 1487CM1 1487DM1 1487EM1 2" Nipple 1487M2 1487CM2 1487DM2 1487EM2 3" Nipple 1487M3 1487CM3 1487DM3 1487EM3 6" Nipple 1487M6 1487CM6 1487DM6 1487EM6 ox Entry Swivel Nipple 1487V1 1487CV1 1487DV1 1487EV1 Standard Swivel Nipple 1487V2 1487CV2 1487DV2 1487EV2 Flexible Fitting 1485FF CFF DFF EFF 1 djustable Fitting 1487X CX DX EX 1 Cut-Off Fitting 1487W CW DW EW 1 90 Elbow 14879P 1487C9P 1487D9P 1487E9P 45 Elbow 14874P 1487C4P 1487D4P 1487E4P 22.5 Elbow 14872P 1487C2P 1487D2P 1487E2P Tee Fitting 1487T 1487CT 1487DT 1487ET Cross Fitting 1487Y 1487CY 1487DY 1487EY Center Hole Reducers Reducer - 4 x 4 to 2.5 x CRC 2 Reducer - 6 x 6 to 4 x DRC 2 Reducer - 8 x 8 to 4 x ERCC 2 Reducer - 8 x 8 to 6 x ERCD 2 Edge Hole Reducers Reducer 4 x 4 to 2.5 x CRE 2 Reducer 6 x 6 to 4 x DRE 2 Reducer 8 x 8 to 4 x EREC 2 Reducer 8 x 8 to 6 x ERED 2 ox Connector 1487K CK DK EK 1 Drop Hanger 1485L CL DL EL1 1 racket Hanger 1485L CL DL EL2 1 Cover Plate 1487H CH DH EH 2 Gasket & Screws 1487S CS DS ES 1 1 Does not meet CS or UL requirements 2 Maintains ratings on CS and UL approved wireway Wireway & Trough Pull Through Wireway 331
15 1487 Series Pull Through Wireway - NEM 12 Typical Straight C=12" C=24" C=36" C=48" C=60" C=120" x C C C C C C120 4 x D D D D D D120 6 x E E E E E E120 8 x 8 Wireway & Trough Pull Through Wireway Partition (arrier) Kit Divides wireway into two or more compartments. arriers are fastened to wireway sections with screws. X 1487C60 4 x D60 6 x E60 8 x Does not meet CS or UL requirements Typical Nipple 1" Nipple ox Entry or Standard Swivel Nipple ox Entry Swivel Nipple 2" Nipple 3" Nipple Standard Swivel Nipple 6" Nipple 1487V V x CV CV2 2 4 x DV DV2 2 6 x EV EV2 2 8 x M1 1487M2 1487M3 1487M6 2.5 x CM1 1487CM2 1487CM3 1487CM6 4 x DM1 1487DM2 1487DM3 1487DM6 6 x EM1 1487EM2 1487EM3 1487EM6 8 x 8 332
16 1487 Series Pull Through Wireway - NEM 12 3" to 10" Flexible Fitting llows for easy alignment of sections or fittings Metal flanges Flexible synthetic "bellows" middle section 1485FF CFF DFF EFF Elbow J 14879P 2.5 x C9P 4 x D9P 6 x E9P 8 x djustable Fitting llows on site length adjustment of 1.5" to 13.5" 1487X 2.5 x CX 4 x DX 6 x EX 8 x 8 Does not meet CS or UL requirements 45 Elbow K 14874P 2.5 x C4P 4 x D4P 6 x E4P 8 x Cut-Off Fitting (Lay-In) ody comes in two pieces. Cut-off one piece, shorten cover, and weld together. Includes angle sealing plate. 1487W 2.5 x CW 4 x DW 6 x EW 8 x 8 Does not meet CS or UL requirements 22.5 Elbow V 14872P 2.5 x C2P 4 x D2P 6 x E2P 8 x Wireway & Trough Pull Through Wireway 333
17 1487 Series Pull Through Wireway - NEM 12 Wireway & Trough Pull Through Wireway Tee Fitting H M 1487T 2.5 x CT 4 x DT 6 x ET 8 x Cross Fitting H M 1487Y 2.5 x CY 4 x DY 6 x EY 8 x ox Connector E G 1487K 2.5 x CK 4 x DK 6 x EK 8 x Cover Plate E G 1487H 2.5 x CH 4 x DH 6 x EH 8 x Drop Hanger T U 1485L1 2.5 x CL1 4 x DL1 6 x EL1 8 x racket Hanger R W 1485L2 2.5 x CL2 4 x DL2 6 x EL2 8 x
18 1487 Series Pull Through Wireway - NEM 12 Reducers (Center Hole) Reduces from to E G 1487CRC 4 x x DRC 6 x 6 4 x ERCC 8 x 8 4 x ERCD 8 x 8 6 x Reducers (Edge Hole) Reduces from to E G 1487CRE 4 x x DRE 6 x 6 4 x EREC 8 x 8 4 x ERED 8 x 8 6 x Wireway & Trough Pull Through Wireway 335
19 Lay In Wireway NEM 1 pplication Construction designed to ensure electrical continuity and to permit fast and easy indoor installation of multiple wireway runs. Standards UL-50 Type 1 cul Type 1 Complies with IEC 6029, IP20 Construction Formed from 16 or 14 gauge steel. Hinged covers and Joiners make it possible to lay in continuous run of cables. Covers are hinged on 24 centers (max) standard 1/4 wrench or socket is the only tool required for assembly. dequate concentric knockouts (1/2, 3/4 conduit size) are standard on straight lengths. Knockouts are on 12 centers. arriers to separate different cable voltages are available as an accessory. Unobstructed interior speeds up laying of cables. Joiner included with the straight sections. Optional hanger brackets allow for vertical and horizontal mounting. Finish s and components are finished in NSI 61 gray. Couplings are unpainted galvanized. 336
20 Lay In Wireway NEM x x 4 6 x 6 8 x 8 Straight 12 CWST212 CWST412 CWST612 CWST812 Straight 24 CWST224 CWST424 CWST624 CWST824 Straight 36 CWST236 CWST436 CWST636 CWST836 Straight 48 CWST248 CWST448 CWST648 CWST848 Straight 60 CWST260 CWST460 CWST660 CWST860 Straight 72 CWST272 CWST472 CWST672 CWST872 Straight 96 CWST296 CWST496 CWST696 CWST896 Straight 120 CWST2120 CWST4120 CWST6120 CWST8120 Straight arrier 12 CW212 CW412 CW612 CW812 Straight arrier 24 CW224 CW424 CW624 CW824 Straight arrier 36 CW236 CW436 CW636 CW836 Straight arrier 48 CW248 CW448 CW648 CW848 Straight arrier 60 CW260 CW460 CW660 CW860 Straight arrier 72 CW272 CW472 CW672 CW872 Straight arrier 96 CW296 CW496 CW696 CW896 Straight arrier 120 CW2120 CW4120 CW6120 CW8120 Elbow 90 degrees CWEL290 CWEL490 CWEL690 CWEL890 Elbow 45 degrees CWEL245 CWEL445 CWEL645 CWEL845 Elbow 22.5 degrees CWEL222 CWEL422 CWEL622 CWEL822 Tee Fitting CWTF2 CWTF4 CWTF6 CWTF8 Cross Fitting CWCF2 CWCF4 CWCF6 CWCF8 Reducer 4 x 4 to 2.5 x CWRD Reducer 6 x 6 to 4 x CWRD64 - Reducer 8 x 8 to 6 x CWRD86 racket Hanger Ceiling Type CWHD2 CWHD4 CWHD6 CWHD8 racket Hanger Wall Type CWHW2 CWHW4 CWHW6 CWHW8 Closing Plate CWCP2 CWCP4 CWCP6 CWCP8 dapter (ox Connector) CWD2 CWD4 CWD6 CWD8 Joiner CWJO2 CWJO4 CWJO6 CWJO8 Telescope Fitting CWTL2 CWTL4 CWTL6 CWTL8 337
21 Lay In Wireway NEM 1 Straight C =12 =24 =36 =48 =60 =72 =96 =120 CWST212 CWST224 CWST236 CWST248 CWST260 CWST272 CWST296 CWST CWST412 CWST424 CWST436 CWST448 CWST460 CWST472 CWST496 CWST CWST612 CWST624 CWST636 CWST648 CWST660 CWST672 CWST696 CWST CWST812 CWST824 CWST836 CWST848 CWST860 CWST872 CWST896 CWST Straight arrier =11.88 =23.88 =35.88 =47.88 =59.88 =71.88 =95.88 = CW212 CW224 CW236 CW248 CW260 CW272 CW296 CW CW412 CW424 CW436 CW448 CW460 CW472 CW496 CW CW612 CW624 CW636 CW648 CW660 CW672 CW696 CW CW812 CW824 CW836 CW848 CW860 CW872 CW896 CW C Reducer C CWRD42 4 x 4 to 2.5 x CWRD64 6 x6 to 4 x CWRD86 8 x8 to 6 x Cross Fitting CWCF CWCF4 4 9 CWCF CWCF Tee Fitting C CWTF CWTF CWTF CWFT
22 Lay In Wireway NEM 1 Elbow 90 Elbow 45 Elbow 22.5 CWEL CWEL CWEL CWEL racket Hanger Ceiling Type (max.) CWHD CWHD CWHD CWHD CWEL CWEL CWEL CWEL Closing Plate Knockout CWCP CWCP CWCP CWCP CWEL CWEL CWEL CWEL dapter (ox Connector) CWD2 2.4 CWD4 3.9 CWD6 5.9 CWD8 7.9 racket Hanger Wall Type CWHW CWHW CWHW CWHW Joiner CWJO2 2.5 CWJO4 4.0 CWJO6 6.0 CWJO8 8.0 Telescope Fitting CWTL CWTL CWTL CWTL
Industrial Wireway & Trough
308 Lay-In Wireway 1485 Series - NEMA 12... 310-319 Wiring Trough 1486 Series - NEMA 12... 320 Pull Through Wireway 1487 Series - NEMA 12... 322-328 309 1485 Series Lay-In Wireway - NEMA 12 Lay-In Wireway
More informationConstruction. Quality Products. Service Excellence.
1485 Series - NEMA 12 www.hammondmfg.com Application Designed to enclose and protect electrical wiring from dirt, dust, oil and water. All sections and fi ttings are completely open on each side to allow
More information1953LCV1. Laser Chip. KeyFeatures. Applications. For moreinfo. Laser Chip on Submount 1064 CHP
Chip 1064 CHP KeyFeatures Distributed Feed Back (DFB) Laser InGaAsP Strained Quantum Well Laser Structure on InP Buried Ridge Stripe (BRS) Low Beam Divergence (FWHM) of 25 x 25 Output Power: 20mW, 40mW
More informationSPARE CONNECTORS KTM 2014
SPAREPARTSCATALOG: // ENGINE ART.-NR.: 3208201EN CONTENT CONNECTORS FOR WIRING HARNESS AA-AN CONNECTORS FOR WIRING HARNESS AO-BC CONNECTORS FOR WIRING HARNESS BD-BQ CONNECTORS FOR WIRING HARNESS BR-CD
More informationSPAREPARTSCATALOG: CONNECTORS SPARE CONNECTORS KTM ART.-NR.: 3CM EN
SPAREPARTSCATALOG: CONNECTORS ART.-NR.: 3CM3208201EN CONTENT SPARE CONNECTORS AA-AN SPARE CONNECTORS AO-BC SPARE CONNECTORS BD-BQ SPARE CONNECTORS BR-CD 3 4 5 6 SPARE CONNECTORS CE-CR SPARE CONNECTORS
More informationIdeal protection for your electrics: häwa cable ducts
Ideal protection for your electrics: häwa cable ducts Well Conceived The häwa group has established itself as an innovative and highly competent supplier to machinery and facility equipment companies in
More informationTYPE 4/12 PREMIER SERIES
Type 4 / 12 Enclosures TYPE 4/12 PREMIER SERIES ENCLO- Contemporary Contemporary Design Design Seamless Seamless Foam-In-Place Foam-In-Place Gasketing Gasketing Utility Utility Brackets Brackets for for
More informationMIRROR POLISHED POSTS See page 46
PRE-ASSEMBLED POSTS We now offer the largest range of pre-assembled posts from stock. Straight out of the box and ready to bolt down or side fix. See the following pages to find the most suitable design.
More information151 SAGINAW CONTROL & ENGINEERING STOCK PRICE LIST
151 SAGINAW CONTROL & ENGINEERING STOCK PRICE LIST Saginaw Control & Engineering s are designed to work in a wide range of environments indoors or outdoors, and house electronic controls, instruments,
More informationPanel Enclosures. Wall-Mount Enclosures Type 12 Premier Series Double-Door with Quarter-Turn Latches Data Sheet
Panel Enclosures Wall-Mount Enclosures Type 12 Premier Series Double-Door with Quarter-Turn Latches Data Sheet Construction Enclosure and door are fabricated from code gauge steel (see page 153) All continuous
More informationFree-Standing Type 12 Enclosures
Type 12 Enclosures Application Designed to protect electrical and electronic controls, components, and instruments in typical industrial environments. The UL Type 12 rating protects enclosed equipment
More informationCONCEPT Stainless Steel Wall-Mount Enclosures
CONCEPT Stainless Steel Wall-Mount Finish are unpainted. Door and body have smooth #4 brushed finish. Optional CONCEPT panels are white painted or zinc-plated. Optional NEMA panels are white painted, zinc-plated,
More informationFree-Stand Universal-Cutout Disconnects Type 12 Modular Free-Stand Disconnects and Accessories
Spec-00252 Free-Stand Universal-Cutout Disconnects Type 12 Modular Free-Stand Disconnects and Accessories Modular Disconnect Enclosure, Type 12 INDUSTRY STANDARDS UL 508A Listed; Type 12; File No. E61997
More informationFree-Stand Universal-Cutout Disconnects Type 12 Modular Free-Stand Disconnects and Accessories
763.422.2600 SPEC-00252 N763.422.2211 DISCONNECT FREE-STAND UNIVERSAL-CUTOUT DISCONNECTS TYPE 12 MODULAR FREE-STAND DISCONNECTS AND ACCESSORIES Free-Stand Universal-Cutout Disconnects Type 12 Modular Free-Stand
More informationType 4X S.S. Disconnect Enclosures
201 SAGINAW CONTROL & ENGINEERING STOCK PRICE LIST Saginaw Control & Engineering s Type 4X S.S.Disconnect Enclosures are designed to work in a wide range of environments indoors or outdoors, and house
More informationType 4 Disconnect Enclosures
143 SAGINAW CONTROL & ENGINEERING STOCK PRICE LIST Saginaw Control & Engineering s are designed to work in a wide range of environments indoors or outdoors, and will house most standard types of disconnects
More informationST-B. Plugs for Membranes. Product Description. Advantages & Benefits. Specifications. Compatible with
ST-B Plugs for Membranes D1 L D2 2 Plugs ST-B are used to seal already pierced membranes in various cable entry plates (KEL-DPU / KEL-DPZ / KEL-DP / KEL-QTA-DP) and DT grommets. Perfect for applications
More informationFree-Stand Universal-Cutout Disconnects Type 12 Modular Free-Stand Disconnects and Accessories
763.422.2600 Spec-00252 L763.422.2211 Free-Stand Universal-Cutout s Type 12 Modular Free-Stand s and accessories Free-Stand Universal-Cutout s Type 12 Modular Free-Stand s and Accessories Modular Enclosure,
More informationALPHA Small Distribution Boards SIMBOX 63/SIMBOX WP
ALPHA Small Distribution Boards SIMBOX 63/SIMBOX WP SIMBOX 63 /4 Introduction /5 Flush mounting distribution boards /6 Hollow-wall distribution boards /7 Surface mounting distribution boards /7 Hood-type
More informationCABLE ROUTING SYSTEMS. WIRE CABLE TRAYS - standard open trays PRODUCT INFORMATION
C L E S N I T T I O N CLE ROUTING SYSTEMS WIRE CLE TRYS - standard open trays PROUCT INFORMTION Table of Contents Open cable trays S25 - S26, S30M - S35W.... Pgs 4-5 Open cable trays S36 - S39W, S30- -
More informationLevel instruments. Communications and Displays SITRANS RD200. 5/306 Siemens FI Technical specifications. Overview
Overview The is a universal input, panel mount remote digital display for process instrumentation. Benefits Easy setup and programming via front panel buttons or remotely using RD software Display readable
More informationFree-Stand Universal-Cutout Disconnects Free-Stand Type 4 Disconnects
Spec-01054 Free-Stand Universal-Cutout Disconnects Free-Stand Type 4 Disconnects Free-Stand Disconnect with Quick-Release Continuous Hinge, Type 4 APPLICATION Simple, heavy-duty with easy door removal
More informationAP-120 Series AP Mounting Kit
AP-120 Series AP Mounting Kit Installation Guide The AP-120 series mounting kit provides additional mounting options for the AP-120 series wireless access points. The mounting kit includes the following
More informationStandard Product. Catalog Number. Width. Depth. mm 18 = = = = = = = = 400
Spec-01195 PROLINE G2 External Components Bases Gland Plate Gland plates are used with a plinth base to provide cable management solutions while maintaining a NEMA 12 rating. PROLINE G2 s unique Duro-Stand
More information1/2 Introduction. SIMBOX LC 1/7 Introduction 1/8 Flush-mounting and surfacemounting. 1/9 Dimensional drawings
Siemens AG 200 ALPHA SIMBOX Small Distribution Boards /2 Introduction /2 Introduction /3 Flush-mounting and hollow-wall distribution boards /4 Hood-type distribution boards /5 Accessories /6 Dimensional
More informationTopConsole system TP. Combination options 1-part 2-part 3-part. System accessories Page 537 Monitors, keyboards From page 796 Climate control Page 389
opconsole system P System accessories Page 537 Monitors, keyboards From page 796 Climate control Page 389 Enclosure: Sheet steel 1.5 mm Door and console cover: Sheet steel, 2.0 mm, all-round foamed-in
More informationSEQUESTR PREfERREd-CUToUT disconnects Mild STEEl SEQUESTR ExTERnal disconnect PaCkagE, TyPE 12 industry STandaRdS application finish SPECifiCaTionS
Spec-224 Mild Steel SEQUESTR External isconnect Package, Type 12 INUSTRY STANARS UL 58A Listed; Type 12; File No. E61997 cul Listed per CSA C22.2 No. 94; Type 12; File No. E61997 NEMA/EEMAC Type 12 CSA
More informationFree-Stand Universal-Cutout Disconnects Free-Stand Type 4 Disconnects
763.422.2600 SPEC-01054 C763.422.2211 DISCONNECT FREE-STAND UNIVERSAL-CUTOUT DISCONNECTS FREE-STAND TYPE 4 DISCONNECTS FREE-STAND DISCONNECT WITH QUICK-RELEASE CONTINUOUS HINGE, TYPE 4 APPLICATION Simple,
More informationParts and Service Manual IMCO
XXTREME ADVANTAGE Gimbal Parts and Service Manual IMCO 510 East Arrow Highway San Dimas, CA 91773 (800) 899-8058 (909) 592-6162 Fax (909) 592-6052 www.imcomarine.com email info@imcomarine.com TABLE OF
More informationFree-Stand Universal-Cutout Disconnects Free-Stand Type 12 Disconnects
763.422.2600 SPEC-00250 N763.422.2211 DISCONNECT FREE-STAND UNIVERSAL-CUTOUT DISCONNECTS FREE-STAND TYPE 12 DISCONNECTS Free-Stand Universal-Cutout Disconnects Free-Stand Type 12 Disconnects TWO-DOOR WITH
More informationLinear Luminaire with LED Series 6012/5
> For use in Zones 1 & 2, 21 & 22 > Latest LED technology with a high luminous efficacy and a long service life > Extra flat version for low mounting depth > Powder-coated sheet-steel or brushed stainless
More informationArecont Vision MegaDome 2 Installation Manual (DN Models Only)
recont Vision MegaDome 2 Installation Manual (DN Models Only) 0 P age recont Vision MegaDome 2 Installation Manual (DN Models Only) MegaDome 2 Installation Manual (DN Models Only). recont Vision MegaDome
More informationArecont Vision MegaDome Installation Manual
0 P age MegaDome Installation Manual. recont Vision MegaDome B. Mounting template C. Magnetic core D. Pack of four (4) wood screws and four (4) dry wall anchors E. One double sided hex key F. One single
More informationEPIC Circular Connectors CIRCON M23 Series
The M3 connectors have many inherent features which offer application advantages and provide significant benefits for the customer. These features make it one of the most application friendly connectors
More informationSafety switches with separate actuator
A Safety switches with separate actuator Selection diagram VF KEYF VF KEYF1 VF KEYF2 VF KEYF3 VF KEYF VF KEYF ACTUATORS CONTACT BLOCKS 9 snap action overlapped FD FP FL FC 21 22 33 3 3NC 2NO+1NC 1NO+ CONDUIT
More informationAccessories for control enclosures. BERNSTEIN attachment solutions. Double coupling head (console version with suspension system attachment)
25 Accessories for control enclosures BERNSTEIN attachment Single coupling head (suspended console version) Double coupling head (console version with suspension system attachment) 322.5 231 232 140 The
More informationProduct Specifications 18 inch Wall Duct
NOVA Energy & Automation Product Specifications 18 inch Wall Duct W183560 Ferrous and Non Ferrous 03 January 2012 : WD18 Product 1. Large Capacity Wire Ways Large capacity metal wire ways are commonly
More informationUL 508A Listed; Type 12; File No. E61997 cul Listed per CSA C22.2 No. 94; Type 12; File No. E CSA File No : Type 12
Spec-224 SEQUESTR Preferred-Cutout isconnects SEQUESTR External isconnects Mild Steel SEQUESTR External isconnect Package, Type 12 INUSTRY STANARS UL 58A Listed; Type 12; File No. E61997 cul Listed per
More informationInstallation and Assembly: 2 x 2 Video Wall Ceiling Mount for 40" - 55" flat Panel Displays
Installation and Assembly: 2 x 2 Video Wall Ceiling Mount for 40" - 55" flat Panel Displays Model: DS-VWT955-2X2 EXTENSION COLUMN (SOLD SEPARATELY) COMPATIBILITY Display width must be a minimum of 36"
More informationFeatured Products in this Chapter. Subject to change without notice PH FX hoffmanonline.com 2010 Pentair Technical Products
CHAPTER : Disconnect Featured Products in this Chapter CONCEPT Disconnect Enclosure, Type 4X P. 319 Fiberglass Disconnect, Type 4X P. 328 WATERSHED Disconnect Enclosure, Type 4X P. 340 SEQUESTR External
More informationLinear Luminaire with LED Series 6412/5
> For use in Zones 2, 21 & 22 > Latest LED technology with a high luminous efficacy and a long service life > Extra flat version for low mounting depth > Powder-coated sheet-steel or brushed stainless
More informationLevel Measurement Continuous level measurement - Ultrasonic transducers
Overview transducers use ultrasonic technology to measure level in a wide range of liquids and solids. Benefits Integral temperature compensation Low ringing effect reduces blanking distance Optional foam
More informationStandard Product Left-Hinged
Spec-01118 PROLINE G2 Modular Enclosure Solutions Enclosure Packages Industrial Packages, Type 12 INUSTRY STANARS UL 508A Listed; Type 12; File Number E61997 NEMA/EEMAC Type 12 CSA File Number 42186; Type
More informationNational Light Sources Pty Ltd Electrical Accessories - Date 8th April, Coombes Drive, Penrith, NSW, 2750 Australia
National Light Sources Pty Ltd 15 Coombes Drive, Penrith, NSW, 2750 Australia 15 Coombes Drive Penrith NSW 2750 Tel: 02-4732 5444 Fax: 02-4732 6600 Email: sales@nlslight.com.au Product list for Electrical
More informationStandard Product Left-Hinged
Spec-01118 PROLINE G2 Modular Enclosure Solutions Enclosure Packages, Type 12 Industrial Packages, Type 12 INUSTRY STANARS UL 508A Listed; Type 12; File Number E61997 NEMA/EEMAC Type 12 CSA File Number
More informationHubbell Metal Raceway HBL3000 Series Product Applications
Hubbell Metal Raceway HBL3000 Series Product Applications 3 5 6 4 7 1 2 8 Description Description 1 HBL3000CEIV HBL3000BIV 5 ft. Cover 10 ft. Base 5 HBL3048RIV Rectangular Receptacle Cover and Device Bracket
More informationnls Product List 1st February, 2014 Tel: Fax: Coombes Drive, Penrith, NSW, 2750 Australia
15 Coombes Drive, Penrith, NSW, 2750 Australia 15 Coombes Drive Penrith NSW 2750 Tel: 02-4732 5444 Fax: 02-4732 6600 Email: sales@nlslight.com.au Product list for Electrical Accessories Code Item Inner
More information2-Type Series Pressurized Closures
2-Type Series Pressurized Closures A complete pressure tight reenterable closure system for enclosing spliced connections of communications cables in a wide variety of applications. The 2-type Closure
More informationLAMIBLOC laminated shims
LAMIBLOC laminated shims For all special requirements LAMIBLOC laminated shims are used wherever conventional s are just not enough. Each 1 mm shim is composed of 20 layers, each 0.05 mm thick. The user
More informationHan PCB termination. Han-Fast Lock PCB adapter for Han DD PCB adapter for Han DDD module
Han termination Contents Page Han-Fast Lock... 20.11 adapter for Han DD... 20.13 adapter for Han DDD module... 20.16 adapter for Han 40 A Axial module... 20.18 adapter for Han E... 20.20 adapter for Han
More informationUniversal Tablet Enclosure 13 Inch and Under for Microsoft Surface Pro 3 and 4 PN MSPRO4
1-of-9 PRODUCT SPECIFICATIONS PN 80923-MSPRO4 is designed to support the MICROSOFT SURFACE PRO 4 (11.50 x 7.93 x.33) and includes the following items: Universal Tablet Enclosure 13 Inch and Under Assembly
More informationEmergency Luminaire for Fluorescent Lamps Series EXLUX 6009
> As wall, ceiling and pendant light fitting or pole mounted light fitting > Version with 2 lamps: 18 W and 36 W > Central locking > All-pole disconnection via N/C switch when opening light fitting or
More informationCABLE ROUTING SYSTEMS. WIRE CABLE TRAYS - locking trays PRODUKTINFORMATION
C B L E S N I T T I O N CBLE ROUTING SYSTEMS WIRE CBLE TRYS - locking trays PRODUKTINFORMTION Table of Contents. Locking Cable Trays S20 - S22N, S121-S123.... Pgs 4-5 Locking Cable Trays K25 - K91... Pgs
More informationFree-Stand Stainless Steel Preferred-Cutout Disconnects Stainless Steel Two-Door Disconnects US 5,634,357 D 385,7683 BULLETIN: A21S4
763.422.2600 SPEC-00384 J763.422.2211 DISCONNECT FREE-STAND STAINLESS STEEL PREFERRED-CUTOUT DISCONNECTS STAINLESS STEEL TWO-DOOR DISCONNECTS Free-Stand Stainless Steel Preferred-Cutout Disconnects Stainless
More informationUS 5,634,357 D 385,7683 Bulletin: A21S4
763.422.2600 Spec-00384 H763.422.2211 Free-Stand Stainless Steel Preferred-Cutout s Stainless Steel Two-Door s Free-Stand Stainless Steel Preferred-Cutout s Stainless Steel Two-Door s Two-Door Stainless
More informationPROLINE ExtERNaL COmPONENts 0-mm solid BasE Catalog Number Fits Frame B x C W (mm) W (in.) D (mm) D (in.) PB045 PB046 PB064 PB064HF2 PB065HF2 PB066
Spec-00429 PROLINE External Components PROLINE Tops and Bases 0-mm Solid Base The 0-mm bases are finished with RAL 7035 textured light-gray polyester powder paint (except stainless steel). EMC bases are
More informationSafety switches with separate actuator
Safety switches with separate actuator Selection diagram VF KEYD VF KEYD1 VF KEYD VF KEYD VF KEYD5 VF KEYD6 VF KEYD7 VF KEYD8 VF KEYD10 VF KEYD11 ACTUATORS FR FX FK FW 5 6 7 11 1 14 NC NC snap action snap
More informationFiberglass. Spec L. Non-Metallic. Hinge-Cover with 3-Point Latch or Quick-Release Latches, Type 4X
763.22.2600 Spec-00092 L763.22.2211 Fiberglass Hinge-Cover with 3-Point Latch or Quick-Release Latches Fiberglass Hinge-Cover with 3-Point Latch or Quick-Release Latches Hinge-Cover with 3-Point Latch
More informationSafety switches with manual mechanical delay and separate actuator
D Safety switches with manual mechanical delay and separate actuator Selection diagram VF KEYF VF KEYF1 VF KEYF VF KEYF VF KEYF7 VF KEYF ACTUATORS MECHANICAL DELAY C L L0 Short knob 0 sec. Short knob sec.
More informationNominal. Mounting. Length foot foot RUN Nominal Lengths* Suspension Bracket 1 Studs (Factory installed) Rotating Crossbar
M125 Project: Type: Qty: Series Lamping Mounting Nominal Length Finish Voltage Options Series M125R1 Flanged M125R2 Flanged / Flush Endcaps M125 For Concrete Pour Only Lamping 1T5 2T5 1T8 2T8 1T5HO 2T5HO
More informationoberonwireless.com Secure Infrastructure Solutions For Wireless Networks Product Catalog 2012
oberonwireless.com Secure Infrastructure Solutions For Wireless Networks Product Catalog 2012 Table of Contents 3 Welcome to Oberon Suspended Ceiling Enclosures 5 Model 1030 FLANGE & 1030 00 6 Model 1036
More informationCom-Tray. Under Floor. Labor-saving assembly Field proven and tested Superior construction Shipped ready to assemble
Com-Tray Chalfant, a leading supplier of cable trays and systems for utilities, industrial plants, and commercial service, offers Com-Tray, a unique modular, cost-saving system for routing and protecting
More informationPROLINE ExtERNal ComPONENts. PROLINE tops and Bases
Spec-00429 H763.422.2211 763.422.2600 PROLINE ExtERNal ComPONENts PROLINE Tops and Bases PROLINE ExtERNal ComPONENts PROLINE tops and Bases 0-mm Solid Base The 0-mm bases are finished with RAL 7035 textured
More informationUS 5,634,357 D 385,7683 Bulletin: A28S4
763.422.2600 Spec-00385 J763.422.2211 Free-Stand Stainless Steel Preferred-Cutout s Stainless Steel Heavy Duty s Free-Stand Stainless Steel Preferred-Cutout s Stainless Steel Heavy Duty s Stainless Steel
More informationFree-Stand Type 12 Disconnect Enclosures. Heavy-Duty Free-Stand Disconnect Enclosure, Type 12
Spec-00251 FPH FX (763) 422-2600 422-2211 Disconnect Free-Stand Universal-Cutout Disconnect Enclosures Heavy-Duty Free-Stand Disconnect Enclosure, Type 12 Industry Standards UL 508A Listed; Type 12; File
More informationFree-Stand Stainless Steel Preferred-Cutout Disconnects Stainless Steel Heavy Duty Disconnects US 5,634,357 D 385,7683 BULLETIN: A28S4
763.422.2600 SPEC-00385 L763.422.2211 DISCONNECT FREE-STAND STAINLESS STEEL PREFERRED-CUTOUT DISCONNECTS STAINLESS STEEL HEAVY DUTY DISCONNECTS Free-Stand Stainless Steel Preferred-Cutout Disconnects Stainless
More informationWe provide superior performing compressed air & gas systems with engineered longevity to reduce operating costs and improve productivity.
We provide superior performing compressed air & gas systems with engineered longevity to reduce operating costs and improve productivity. ENGINEERED FOR SUPERIOR PERFORMANCE Compressed Air & Gas Systems
More informationStandard Product One-Door Enclosures. Free-Stand Universal-Cutout Disconnects Free-Stand Type 12 Disconnects
Spec-00251 Free-Stand Universal-Cutout Disconnects Free-Stand Type 12 Disconnects Heavy-Duty Free-Stand Disconnect Enclosure, Type 12 SPECIFICATIONS 11 gauge steel (.121 inch) Seams continuously welded
More informationSarix Professional IMP Series 3.75 Indoor Dome. Quick Start Guide IMP121-1IS IMP221-1IS IMP321-1IS IMP521-1IS C2291M-B-EN (12/16)
Sarix Professional IMP Series 3.75 Indoor Dome Quick Start Guide IMP121-1IS IMP221-1IS IMP321-1IS IMP521-1IS C2291M-B-EN (12/16) Sarix Professional IJP Series 2 Micro Indoor Dome Quick Start Guide IJP121-1IS
More informationFormulate 20 Vertical Curve
Formulate 20 Vertical Curve FMLT-WV20-03 Formulate TM is a collection of sophisticated, ergonomically designed exhibit booths. Formulate combines state-of-the-art zipper pillowcase dye-sublimated fabric
More informationMagnetek Dynamic Braking Resistors
Magnetek Dynamic Braking Resistors Motor Control Instruction Manual N49 W13650 Campbell Drive Menomonee Falls, WI 53051 Phone: 1-800-288-8178 Fax: 1-800-298-3503 SERVICE: 1-866-MAG-SERV (1-866-624-7378)
More informationArgenta W A L L M O U N T I N G M E T A L C A B I N E T S
Argenta W A L L M O U N T I N G M E T A L C A B I N E T S The ARGENTA Series is a group of metal enclosures used to house on the inside electrical or electronic switchgear, controlgear and equipment necessary
More informationSafety switches with separate actuator
4 Safety switches with separate actuator Selection diagram VF KEYD VF KEYD1 VF KEYD VF KEYD VF KEYD VF KEYD6 VF KEYD VF KEYD10 ACTUATORS CONTACT BLOCKS 6 snap action overlapped FR FX FK FW 0 1 4 NC NO+1NC
More informationPower-Over-Ethernet (PoE) Weatherproof 14 x12 x7 Enclosure with Mounting Plate and Cooling Fan. Model: NB F. Applications and Features
Power-Over-Ethernet (PoE) Weatherproof 14 x12 x7 Mounting Plate and Cooling Fan Model: NB141207-40F Applications and Features Applications: Remote Wireless LAN WiFi equipment installations using Power-Over-
More informationEJB Junction Boxes Dimensions Pg. 132
6F EJB Junction Boxes Dimensions Pg. 132 Application: EJB junction boxes are used in threaded rigid conduit systems in hazardous areas: As a junction or pull box To provide enclosures for splices and branch
More informationWaterproof Connectors with Crimp Contacts
Waterproof Connectors with Crimp s Comptatible with JIS-B-6015 CE01 Series Conforming Standard JIS B 6015 Wa t e r p r o o f IP67 Lock Type Bayonet OUTLINE CE01 series is compatible with JIS-B 6015,Japanese
More informationOPAL-RT FIU User Guide.
OPAL-RT FIU User Guide www.opal-rt.com Published by Opal-RT Technologies, Inc. 1751 Richardson, suite 2525 Montreal, Quebec, Canada H3K 1G6 www.opal-rt.com 2013 Opal-RT Technologies, Inc. All rights reserved
More informationProduct catalogue. Aztec International S.A., ul. Bułgarska 63/65, Poznań, Poland, phone ,
Product catalogue Delivery Programme 2014 Status 02/2014 - Subject to change - Index Rail system... 4 Accessories mounting rails... 11 Rail connectors... 11 Cross connectors... 12 Module clamps... 13 Module
More informationWIRE AND CABLE MANAGEMENT
Wire and Cable Management Solutions A variety of items are available for managing and organizing wire and cable in common systems and cabinet environments. From cable rack, auxiliary framing to network
More informationThe 400, 800, and 2300 Series, from
400, 800, 2300, 2300D Surface Nonmetallic Raceway Systems For Low Voltage and Power pplications 400, 800, 2300, 2300D Series Raceway Systems The 400, 800, and 2300 Series, from The Wiremold Company, is
More informationPANELITE ENCLOSURE LIGHTS OVERVIEW
SPEC-00581 H763.422.2211 763.422.2600 ELECTRICAL LIGHTING PACKAGES ELECTRICAL LIGHTING PACKAGES PANELITE ENCLOSURE LIGHTS OVERVIEW FEATURES Slim profile allows light to be tucked up out of the way for
More informationNEMA Enclosure Solutions for Cisco WLAN Deployments
Cisco Systems, Inc. and TerraWave Solutions NEMA Enclosure Solutions for Cisco WLAN Deployments Product Catalog TerraWave Solutions is a Cisco Solution Technology Integrator Cisco Solutions, Inc. and TerraWave
More informationSafety switches for hinged doors
C Safety switches for hinged doors Selection diagram FR FM FX FZ FK 18 7 9 snap action overlapped CONTACT BLOCKS 21 NC 1NO+ CONDUIT ENTRIES Threaded conduit entries (standard) With cable gland assembled
More informationStandard Pushbutton Box
Standard Pushbutton Boxes NEMA Rated Pushbutton Enclosures These NEMA rated boxes are designed for indoor use to house pushbuttons, selector switches, pilot lights, etc., and to protect such equipment
More informationUltima X5000 Round Duct Mount Kit User Instructions
Ultima X5000 Round Duct Mount Kit User Instructions MSA Kit 10179124/10179321 - Ultima X5000 316 Stainless Steel Parts List / Instructions Round Duct Mount Gasket (1) Round Duct Mount Base Plate (1) Base
More informationOutdoor PTZ. Mounting on the Ceiling Using Pendant Mount. Installation Guide. For Models: I93, I94, I95, I96, KCM /12/03
Outdoor PTZ Mounting on the Ceiling Using Pendant Mount For Models: I93, I94, I95, I96, KCM-8211 2013/12/03 Table of Contents Mounting Solutions... 3 Straight Tube Installation Procedures... 4 Step 1:
More informationSensor Accessories Retroreflectors and Retroreflective Tape 8-2
-2 Retroreflectors and Retroreflective Tape PG.05E.17.T.E Retroreflectors ontents Overview.................... -2 Model Selection............... -3 Dimensions.................. -3 High Quality Retroreflectors
More informationVMS Series configuration options and specifications
Vynckier Enclosure Systems 271 McCarty St., Houston, Texas 77029 Phone: (713) 374-7850 Toll Free: (888) 837-1114 Fax: (800) 444-1261 www.vynckier.com VMS Series configuration options and specifications
More informationEMC Shielding Clear plated components (exterior painted) and a conductive fabric-over-foam gasket provide an HF2 level of shielding.
Spec-00418 E763.422.2211 763.422.2600 PROLINE External Components PROLINE Doors, Covers and Sides PROLINE External Components PROLINE Doors, Covers and Sides Door Gasketing, Shielding and Door Bars Overview
More informationTwo Circuit Track Power System IS24 / IS26 / IS28
Two Circuit Track Power System IS24 / IS26 / IS28 DESCRIPTION Two circuit / single neutral track is an affordable and durable solution that features easy installation. Track system is available in 4, 6,
More informationPMCL Series Mounts RACK/CEILING/WALL MOUNTS, UNIVERSAL CAMERA MOUNT, MONITORS
PRODUCT SPECIFICATION control site PMCL Series Mounts RACK/CEILING/WALL MOUNTS, UNIVERSAL CAMERA MOUNT, MONITORS Product Features For Use with VESA -Compliant Monitors Rack Mounts for All 200/300/400 Series
More informationDimensions in mm in mm in. R in mm in mm mm. Weight. Dimensions in.
Wall Termination / Universal Blind End 1.950 in. 49.53 mm 0.463 in. 11.76 mm 1.00 in. 25.4 mm 0.75 in. 19.05 mm 9.50 in. 241.3 mm R 0.156 in. 3.962 mm 1.962 in. 49.83 mm 0.367 in. 9.322 mm 0.962 in. 24.43
More informationLS 5000 series Vibration Level Switch for liquids
Vibration Level Switch for liquids Set-up without adjustment Integrated fault monitoring Unaffected by product variations in density, conductivity, dielectric constant or viscosity Insensitive to foam,
More informationContinuous level measuring system NB 3000 Selection list
Table of contents Page Overview 2 ------------------------------------------------------------------------------------------------------------------- Specifications 3 -------------------------------------------------------------------------------------------------------------------
More informationDIN Rail Mounted Terminals & Accessories
DIN Rail Mounted Terminals & Accessories PAGE PAGE STANDARD CONTA-CONNECT RANGE 253 NEW! CABLECRAFT ABS-S ENCLOSURES 260 DOUBLE & TRIPLE CONTA-CONNECT RANGE 254 NEW! CABLECRAFT ALUMINIUM ENCLOSURES 260
More informationArecont Vision MegaDome TM Installation Manual
0 P age MegaDome Installation Manual. recont Vision MegaDome TM B. Mounting template C. Magnetic core D. Pack of four (4) wood screws and four (4) dry wall anchors E. One double sided hex key F. One single
More informationMounting Options. Maintains NEMA Type 12 and IEC IP55 enclosure rating when properly installed per Hoffman instructions.
763.422.2600 Spec-00560 F763.422.22 Mounting Options SYSPEND 28-MAX Suspension System Mounting Options SYSPEND 28-MAX Suspension System SYSPEND 28-MAX Suspension System, Type 2 TM INDUSTRY STANDARDS Maintains
More informationContinuous level measurement Ultrasonic transducers
Siemens G 2013 Overview transducers use ultrasonic technology to measure level in a wide range of liquids and solids. Benefits Integral temperature compensation Low ringing effect reduces blanking distance
More informationFibox Tempo Junction box NEW. Protection in demanding environments
Junction box NEW Protection in demanding environments IP 65 Tempo Enclosed in seconds! As its name suggests, Tempo doesn t like to hang around. Need an enclosure that s easy on the pocket and installed
More informationPower-Over-Ethernet Weatherproof 18" x 16" x 8" Enclosure with Equipment Mounting Plate and Cooling Fans
Power-Over-Ethernet Weatherproof 18" x 16" x 8" Equipment Mounting Plate and Cooling Fans Applications and Features Applications: Remote Wireless LAN WiFi equipment installations using Power- Over-Ethernet
More information