HV-STYLVENT Series WALL OR WINDOW EXTRACT FANS HV-STYLVENT. Wall or window extract fans. Elegant design harmonising with any environment
|
|
- Dana Clark
- 6 years ago
- Views:
Transcription
1 WALL OR WINDOW EXTRACT FANS Series Complete range of axial flow fans for wall or window mounting applications. All the fans are supplied with tough ABS plastic grilles, shutter and single phase V- 5Hz motor. All the fans are class II insulation and IPX4 rated. The series comprises of diameters: 5, and mm, including several operating options, making them ideally suited for a wide range of general residential, commercial and industrial exhaust or supply ventilation applications. Shutter Reversible Natural ventilation position To prevent air entry and limit heat leakage when the extractor is not operating Extract or supply operation Shutter open, fan off Elegant design harmonising with any environment 7
2 HV- AE versions Standard range HV-M versions - Single-phase motor V5Hz with thermal overload protection - Single operation - Class II insulation - Model and are reversible with CR-5 control accessory - Automatic, thermally actuated shutter HV-5 AE: Positions: OFF - Fan OFF, shutter closed ON - fan ON, working as air extract with shutter open HV- AE: positions (with CR-5 control accessory) HV- AE OFF - Fan OFF/Shutter closed ON - Fan ON/shutter open Fan working as air extract/supplying air REB-R control: Speed controller including a switch to reverse the airflow direction Manually operated models via integral pull cord - Single (HV-5M) or - (HV-M and M) operation - Model and are reversible - Natural ventilation position (shutter open, fan off - except HV-5M) - Neon lights indicating the mode of operation HV-5 M: Positions: Fan OFF, shutter closed Fan ON, working as air extract with shutter open HV- M: HV- M 5 Positions: -Fan stopped and shutter closed -Fan on high working as air extract with shutter open -Fan on low working as air extract with shutter open 4-Fan stopped and shutter open 5-Fan in reverse high supplying air in the room with shutter open HV-A versions Automatic models operated via control unit CR - Single (HV-5A) or - (HV-A and A) operation - Model and are reversible - Natural ventilation position (shutter open, fan off) - Neon lights indicating the mode of operation HV-5 A: Positions: - Fan OFF, shutter closed - Fan OFF, shutter open - Fan ON, working as air extract To operate all these functions use the accessory CR-5 HV- A: HV- A 5 Positions: -Fan stopped and shutter closed -Fan on high working as air extract with shutter open -Fan on low working as air extract with shutter open 4-Fan stopped and shutter open 5-Fan in reverse high supplying air in the room with shutter open To operate all these functions use the accessory CR- 7
3 HV-RC versions Radio control range - Two operation - Natural ventilation position - All model are reversible - Automatic, thermally actuated shutter - Neon light mode of operation indication HV- RC: HV- RC 6 Positions: -Fan stopped and shutter open -Fan stopped and shutter closed -Fan on high working as air extract with shutter open 4-Fan on reverse high supplying air in the room with shutter open 5-Fan on low working as air extract with shutter open 6-Fan in reverse low supplying air in the room with shutter open HVE versions Flush mounted version HVE- AE: same positions that HV- AE HVE- A: 5 same positions that HV- A HVE- RC: 6 same positions that HV- RC STYLVENT Product Summary Operational Specifications Model Flush Single Two Natural Pull Electrical accessories Radio mounted Reversible ventilation cord REB-R CR-5 CR- control HV-5 M HV- M HV- M HV-5 AE HV- AE HV- AE HV-5 A HV- A HV- A HV- RC HV- RC HVE- AE HVE- A HVE- RC Maximum ambient operating temperature for all models: 45ºC. One remote control can operate several HV.RC. In that case, the fans must be installed with a minimum distance of,5 meters between fans. 7
4 Technical characteristics Model Dimensions (mm) Speed (tr/mn) G F Maximum absorbed power (W) Maximum absorbed current (A) High Airflow rate (m /h) Extraction Low Intake Sound pressure level at m (db(a)) High Low HV-5 AE 8, , HV-5 M 8, , HV-5 A 8, , HV- AE 5 4, ,5 HVE- AE 5 4, ,5 HV- M 5 4, ,5 HV- A 5 4, ,5 HVE- A 5 4, ,5 HV- RC 5 4, ,5 HVE- RC 5 4, ,5 HV- AE 5 68, , HV- M 5 68, , HV- A 5 68, , HV- RC 5 68, , Weight Model A B C ø D E F G H Min. Max. Min. Max. Min. Min. HV (kg) Ø D on (no the vidro) glass B HV HV H A E C Dimensions of the HVE flush mounted version
5 Installation in glass or panels from to 5 mm thickness Fast and simple three stage installation The STYLVENT series of fans are designed for of installation in three easy stages. Stage - External grille Once in position, the external grille is held by three rubber plugs which allow the installer to assemble the interior section of the fan. Stage - Support frame To enable easy mounting of the support frame, the holes are tapered and the fixing screws can be located depending on the glass/panel thickness: mm< thickness< mm mm<thickness<5 mm Stage Internal grille Finally, place the lugs on the top of the support frame into the rectangular slots on the front grille it into position. For a wall mounted installation it is necessary to use the extended threaded rod set (see Installation accessories) Installation on walls from 5 to mm thick Before installation, rods must be cut to 5mm less than the thickness of the wall. Cut a hole in the wall in accordance with the dimensions shown in the table (to right). Ensure that internal wall mounting surface is as smooth as possible. On the interior of the wall, mark the fixing hole positions using the support plate as a template. Fit the threaded rods to the external guard using the threaded sleeves. Place the external grille into position and hold in place with the rubber plugs. Then, the installation follows the same stages as in the glass installation except for the support frame installation, which has to be fixed using or 4 screws (HV-5, HV- and HV- models respectively). Ø D Model Ø D H* L* Min. H Max. HV HV HV- 7,5 57, * There are only two diagonal fixing holes for model HV-5. L 74
6 Performance curves Q = Air volume in, m /hr and m /s. Ps = Static pressure in mmwg and Pa. Dry air at ºC and 76 mmhg. Tests carried out according to UNE --89 and BS 848 part. Pst Pst Pst Pa mmwg HV-5 Pa P mmwg HV- Pa P mmwg , ,5 5,8 4,5 4,,5,,5,,5,,5, m /h Q,,,,4,5,6 m /s - Extraction on high. - Extraction on low. - Air intake Acoustic characteristics m /h Q,,4,6,8,,,4,6 m /s HV m /h Q,5,,5,,5, m /s The values shown for the Sound Pressure Levels in the technical characteristics table are measured in db(a) at m (position B) as shown in the diagram. A m B The table below shows the necessary corrections to calculate the Sound Power Level Spectrum SWL, at the inlet (point A) and outlet at high (in Hz). B Inlet Lw(A) HV-5 +5, ,5 HV- +9 +,5 +,5 +6,5 +,5 +5 +,5 HV , , ,5 Outlet Lw(A) HV-5 +6,5 +,5 +8,5 +6,5 +4, ,5 HV- +6,5 + +6, ,5 +,5 HV- +5,5 +, ,5 75
7 Electrical accessories CR-5 Control unit for HV-5 A Fitted with: On/off switch for fan operation. ( - ) On/Off switch for shutter operation One single CR-5 unit can operate up to 5 HV-5 fans. CR- Control unit for HV- A, HV- A and HVE- A Fitted with: A selector for the different modes of fan operation (,,, ) A reversing switch to change the airflow direction (, ) One single CR- unit can operate up to 5 HV- or fans. REB-R Speed controller including a switch to reverse the airflow direction. Only to be used with models HV- AE, HV- AE and HVE- AE Max A. Connection cable A (7) core wire cable for the connection of models HV- A and HV- A to the remote control unit CR-. (Supplied on m rolls as standard) Installation accessories Threaded Rod set Threaded rods and sleeves for use when installing the HV fans on walls from 5 mm up to mm thick Model Electrical supply IP Power Maximum Class Temperature Dimensions Frequency Voltage protection current (mm) (Hz) (V) (VA) (A) L A H REB-R 5-4 IP-4 4 II ( ) -4ûC Control unit CR Control Unit CR
HV-STYLVENT Series WALL OR WINDOW EXTRACT FANS. Wall or window extract fans HV-STYLVENT. Elegant design harmonising with any environment
WALL OR WINDOW EXTRACT FANS HV-STYLVENT Series 688 679 Shutter Reversible Natural ventilation position Complete range of axial flow fans for wall or window mounting applications. All the fans are supplied
More informationNORDgrille Internal grilles
NORDgrille Internal grilles NORDgrille Contents RSP/RSV General grille RPS/RPV General grille RPSL/RPVL Floor grille RSO Transfer air grille RSL Transfer air grille RSM Transfer air grille RSI Exhaust
More informationProduct Information Fan Powered Terminal Unit For under floor ventilation system Type FAT PI/FAT/M/1
TROX Malaysia Sdn. Bhd. (278360-V) 20, Persiaran Bunga Tanjong 1, Senawang Land Industrial Park, 70400 Seremban, Negeri Sembilan Darul Khusus, Malaysia Telephone : (+6) 06-6788188 Telefax : (+6) 06-6788
More informationLOOK hidden linear diffusers
hidden linear diffusers MADEL The hidden linear diffusers are designed to combine the aesthetics with the technical performance. They can be mounted in false ceilings hiding the frame with filler and leaving
More informationSlim duct (AMTTTFNLDEH ) Indoor units
Slim duct (AMTTTFNLDEH ) Slim duct. Specifications 1) Technical specifications Model AM22FNLDEH AM28FNLDEH AMFNLDEH AM4FNLDEH AMFNLDEH Power Supply Ø, #, V, Hz 1,2,22-24, 1,2,22-24, 1,2,22-24, 1,2,22-24,
More informationDESIGNED FOR THE FUTURE A NEW CONCEPT IN HATCH VENTILATION SYSTEMS
DESIGNED FOR THE FUTURE A NEW CONCEPT IN HATCH VENTILATION SYSTEMS THINGS HAVE CHANGED, AND SO HAVE VENTILATION SYSTEMS. WALL SYSTEM HATCH SOLUTIONS ROOF SYSTEM A NEW CONCEPT IN HATCH VENTILATION SYSTEMS.
More information1 - Control and signalling units
Contents 0 - Control and signalling units Selection guide..............................................page /2. Control and signalling units Ø 8 et 2 b LED pilot lights, type XVL A...................................
More informationSlot diffusers, Round duct diffusers IMP Klima 04 Slot diffusers Round duct diffusers 176
B 0 LD- F 9. φ D H H a 8.5 5 5 A E 7 LD- F 8 8.5 9. 5 5 A 7 E LD-/ LD-/ LD- O/ LD- O/ LD- O/ LD- O/.5.5.5.5 LD-/ LD-/ LD-/ LD-/ LD-/ LD-/ 7.5 7.5 07 LD- O/ LD- O/ LD- O/ LD- O/ 5.5 5.5 5.5 5.5 9.5 87.5
More informationSupplementary operating instructions for your air curtain system Controller TMC 500
Supplementary operating instructions for your air curtain system Controller TMC 500 (Translation of the original) Serial number: Year: Please quote this number when contacting customer service! Date 08.04.2016
More informationFEATURES AND BENEFITS. Installation and operation. Controller
DFC 350 & 450 DISPLACEMENT FREE COOLING Function The Dantherm Displacement Free Cooling (DFC) unit is a slim, passive cooling solution designed to remove excess heat from rooms with sensitive equipment.
More informationLH 700. Spare parts list. Forward and reversible plate. Valid from serial number. LH 700 Hatz Electric start 810 mm Bio
LH 00 Spare parts list Forward and reversible plate LH 00 Hatz Electric start 0 mm LH 00 Hatz Electric start 0 mm Bio LH 00 Hatz Electric start 0 mm LH 00 Hatz Electric start 0 mm Bio Valid from serial
More informationGTH. Rectangular double deflection grille QUICK FACTS
Rectangular double deflection grille QUICK FACTS For supply air Adjustable air deflectors Cleanable Installed using mounting frames FHB / FHA or commissioning box TRG Standard colour White RAL 900 -- alternative
More informationCeiling diffusers - visible
Ceiling diffusers - visible About Lindab Comfort and Design Product overview / symbols Theory Ceiling diffusers Ceiling diffusers - visible Plenum boxes Wall diffusers Nozzles Ventiduct Grilles Displacement
More informationINTELLIGENT SERVER. Model: BMS-LSV6E
INSTALLATION MANUAL INTELLIGENT SERVER Model: BMS-LSV6E Thank you very much for purchasing this TOSHIBA INTELLIGENT SERVER. Please read this manual carefully beforehand for proper installation of the SERVER.
More informationProduct and Applications Description. Application Programs. Note. instabus EIB Technical Product Information. June 2005
Product and Applications Description Application Programs The application programs of the dimmer UP 525/01 consist of two elements: the actuating and the sensor program element. The tasks actuating program
More informationDUCTED SPLIT SYSTEMS With Scroll compressors
DUCTED SPLIT SYSTEMS With Scroll compressors 2 Benefits TOTAL COMFORT ON WIDE AREAS The Ducted Blower Split Systems for light commercial applications of DXDXT-M/K series are the ideal solution for keeping
More informationVentilation grille. Dimensions
Ventilation grille B0 Dimensions B+/A+ B-/A- Description B0 is a rectangular aluminium grille with fixed horizontal bars. B0 is used for both supply and exhaust air, and is supplied as standard with springs
More informationStandard Frame Axial Fans
Quick reference guide Standard Frame Axial Fans 2007 Edition about Axair Fans UK Application knowledge : 20 years experience in air movement; from fume handling to refrigeration; from small electronic
More informationLH 700. Spare parts list. Forward and reversible plate. Valid from serial number. LH 700 Hatz Electric start 810 mm Bio
Forward and reversible plate Hatz Electric start 0 mm Hatz Electric start 0 mm Bio Hatz Electric start mm Bio Valid from serial number 0000 0000 0000 Contents Contents General information.....................................................................................................................................
More informationTechnical Concept. Filter Fan Unit RETURN AIR. Type RA-AC Type RA-EC
Technical Concept Filter Fan Unit RETURN AIR Type RA-AC Type RA-EC Filter Fan Unit RETURN AIR Technical Concept Product Description Technical Data M+W Products Filter Fan Units RETURN AIR (FFU-RA) are
More informationSRQ24A. Technical data. Safety notes. Rotary actuator for ball valves Torque 16Nm Nominal voltage AC/DC 24V Control: Open-close Running time 9s
SRQ24A Rotary actuator for ball valves orque 16Nm Nominal voltage AC/DC 24V Control: Open-close Running time 9s echnical data Electrical data Nominal voltage AC 24V, 50/60Hz / DC 24V Nominal voltage range
More informationElectrical Test voltage (Vrms) Service sea level at m M I II
Applications Compact profile and high density connectors for all military and aeronautical purposes Standards MIL-C 38999 Series II - QPL approved NFC 93422 HE 309 VG 96912 series II PAN 6433-1 BS 9522
More informationRound Louvers. Adapters for , 45, 47 & 86. XV.3. Air Distribution
Air Hose 23-0102 2 Low friction, non collapsible, sold in length of 47 (1200 mm) 23-0104 2.5 Low friction, non collapsible, sold in length of 47 (1200 mm) 23-0015 23-0020 23-0025 23-0035 23-0040 2 Collapsible
More informationTemperature controller Ducted systems
2 725 Temperature controller Ducted systems Standard model without zoning functions RRV851 Multifunctional controller used for central control of ducted HVAC systems in combination with a QAX850 master
More information09LD/GD. Air-Cooled Condensers/Air-Cooled Fluid Coolers. Nominal cooling capacity kw 09LD/GD 09GD
Air-Cooled Condensers/Air-Cooled Fluid Coolers 09LD/GD 09GD 09LD/GD Nominal cooling capacity 281-987 kw The 09LD air-cooled condensers are designed for refrigeration plants where a halogenated hydrocarbon,
More informationStandardized valve series MI-01 Connection pattern according to ISO 5599/1, size 1, 5/2- and 5/3-way NG and 1700 Nl/min (1.636 and 1.
Standardized valve series MI-01 Connection pattern according to ISO 5599/1, size 1, 5/2- and 5/3-way NG 9 1610 and 1700 Nl/min (1.636 and 1.728 Cv) Order code Series and function 1) Plug socket see page
More informationCooling System. Cooling System Overview. 16-Slot Line Card Chassis Airflow
This chapter describes the components that make up the cooling system of the Cisco CRS Series Carrier Routing System 16-Slot Line Card Chassis. It contains the following sections: 16-Slot Line Card Chassis
More informationIndicator, round, raised, full face with plastic matt chrome bezel, 22.5 mm mounting, lamp block included. Yellow Green
22.5 mm 3.5 mm IP65 1 A 66 VAC Choose one component from each of the coloured sections to assemble a complete switch. For other options or further information please contact your local sales office. INDICATOR
More informationElectrical data Nominal voltage AC/DC 24 V Nominal voltage frequency. Draft
echnical data sheet LH24A-MF2-P Parmeterisable linear actuator for adjusting dampers and slide valves in technical building installations Air damper size up to approx. m² Actuating force 5 N Nominal voltage
More informationProduct and Applications Description. Example of Operation. Installation Instructions WARNING. Note. Application Programs
Product and Applications Description Example of Operation dimmer UP 525/11 load circuit AC 230 V L1 N The dimmer UP 525/11 is a dimming actuator for mounting in box mounts (a.o. 60 mm Ø, 60 mm depth).
More informationNSK 4482 / NSK 4482B User s Manual
NSK 4482 / NSK 4482B User s Manual Table of Contents Introduction 1.1 Case Specifications......... 2 1.2 Diagram......... 2 Hardware Installation Guide 2.1 Setting Up.......... 3 2.2 Motherboard Installation.......
More informationOV-MCR116. Media Converter Chassis System. User s Manual
OV-MCR116 Media Converter Chassis System User s Manual FCC Class B Certification This equipment has been tested and found to comply with the regulations for a Class B digital device, pursuant to Part 15
More informationFALCON High Flow. Circular ceiling air diffuser for supply air QUICK FACTS
Circular ceiling air diffuser for supply air QUICK FACTS Ceiling air diffuser for supply air in rooms with high ceiling Manual operated change of spread direction as standard Motor operated change of spread
More informationSurface-Mounting Product Ranges
Introduction Overview Light signals SCHUKO socket outlets Two-circuit switches Garages, laundry rooms, laboratories and workshops are often exposed to a lot of heavy-duty activity, which includes the odd
More informationSystem Storage EXP3000 Rack Installation Instructions
System Storage EXP3000 Rack Installation Instructions Review the documentation that comes with your rack cabinet for safety and cabling information. When you install the IBM System Storage EXP3000 in a
More informationINSTALLATION INSTRUCTIONS
Wired Remote Controller 7 Day Programmable Ductless Systems KSACN0401AAA (High Wall Models) KSACN0501AAA (Ducted/Cassette Models) INSTALLATION INSTRUCTIONS NOTE: Read the entire instruction manual before
More informationLiebert XDA Air Flow Enhancer. User Manual
Liebert XDA Air Flow Enhancer User Manual Technical Support Site If you encounter any installation or operational issues with your product, check the pertinent section of this manual to see if the issue
More informationTechnical Concept. Filter Fan Unit LIGHT. Type LIGHT AC Type LIGHT EC
Technical Concept Filter Fan Unit LIGHT Type LIGHT AC Type LIGHT EC Filter Fan Unit LIGHT Technical Concept Product Description Filter Fan Units (FFUs) from M+W Products are designed to provide clean air
More informationEC axial fan - HyBlade
WG-HU- ebm-papst Mulfingen GmbH & Co. KG Bachmühle D- Mulfingen Phone +9 9 - Fax +9 9 - info@de.ebmpapst.com www.ebmpapst.com Limited partnership Headquarters Mulfingen County court Stuttgart HRA 59 General
More informationProduct and Function Description
Product and Function Description and the LED display. The touchscreen can be used to select from up to 6 languages for the display of texts and messages. The room temperature controller integrated in Contouch
More informationGround Power Modules. And Accessories For Healthcare Facilities. Technical Bulletin NAE /
2 Ground Power Modules And Accessories For Healthcare Facilities Technical Bulletin NAE2092320 / 10.2011 Ground Power Modules Hospital grade outlet modules Introduction BENDER series GPM ground and power
More informationMiG2 CONTROLLERS. 2 & 4 Stage General Purpose Controllers, with Air-conditioning Facilities
MiG2 CONTROLLERS 2 & 4 Stage General Purpose Controllers, with Air-conditioning Facilities The MiG2 controllers incorporate: 2 Inputs (Configurable as Resistive, 0 10V, 0 20mA or 4 20mA) 2 or 4 Relay Outputs
More informationPROLINE ExtERNal ComPONENts. PROLINE tops and Bases
Spec-00428 E763.422.2211 763.422.2600 PROLINE ExtERNal ComPONENts PROLINE Tops and Bases PROLINE ExtERNal ComPONENts PROLINE tops and Bases Solid tops Solid Tops are used to close the top opening on an
More informationSeries LS. 30A to 600 Vac SIP Package DC control LS 24 D 16 C. Figure 1 LS relays; dimensions in inches (mm) (See Figure 12 for LS with HS1)
3A to 6 Vac SIP Package DC control Part Number LSD16C LSD1C LS6DC LSD7C LS6D7C LS6D3C Description 16A, Vac 1A, Vac A, 6 Vac 7A, Vac 7A, 6 Vac 3A, 6 Vac Part Number Explanation LS D 16 C NOTES 1) Line Voltage
More informationQXA2000 QXA2001. Condensation Monitor QXA2001 QXA2000 AQX2000
1 542 1542P03 1542P01 1542P02 QXA2001 QXA2000 AQX2000 Condensation Monitor QXA2000 QXA2001 The QXA2000 condensation monitor is used to avoid damage due to condensation on chilled ceilings and in HVAC plant.
More informationBox Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains and Heating Products Tunnel Fans. Systemair Box Fans
Box Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains and Heating Products Tunnel Fans Systemair Box Fans KVD, KVB, KPD & KPB Systemair Group Systemair (Sweden) Systemair (Spain)
More informationOPERATING INSTRUCTIONS PA AMPLIFIER P-1812
OPERATING INSTRUCTIONS PA AMPLIFIER P-1812 Please follow the instructions in this manual to obtain the optimum results from this unit. We also recommend that you keep this manual handy for future reference.
More informationDuct Sensors. Building Technologies HVAC Products. Symaro. for relative humidity and temperature with calibration certificates
1 883 1883P01 1883P02 QFM4160 AQF4150 Symaro Duct Sensors for relative humidity and temperature with calibration certificates QFM41 Operating voltage AC 24 V / DC 1353 Signal output DC 010 V / 420 ma for
More informationCVH Slot Media Converter Chassis Quick Installation Guide
CVH-2000 14-Slot Media Converter Chassis Quick Installation Guide Ver. 1.2-1305 Table of Contents 1. INTRODUCTION... 1 1.1. FEATURES... 1 1.2. PACKAGE CONTENTS... 1 2. HARDWARE DESCRIPTION... 2 REAL PANEL...
More informationFXVMA Variable Air Volume (VAV) Box Controller
FXVMA Product Bulletin FXVMA Issue Date November 21, 2008 FXVMA Variable Air Volume (VAV) Box Controller The FXVMA is an integrated assembly used to control Variable Air Volume (VAV) boxes. The FXVMA consists
More informationPRODUCT SPECIFCATION GS MINI-SAS HD External Cable to Board Connector System. 1 of 14 F. Roger Cheng TYPE NUMBER
1 of 14 F TABLE OF CONTENTS 1.0 OBJECTIVE... 3 2.0 SCOPE... 3 3.0 APPLICABLE DOCUMENTS... 3 3.1 FCI SPECIFICATIONS... 3 3.2 OTHER STANDARDS AND SPECIFICATIONS... 3 3.3 FCI PRODUCT QUALIFICATION TEST REPORTS...
More informationMEVDC2 MULTI POINT E X T R A C T
TE CHI C A I FORM AT IO MUTI POIT E X T R A C T A QUIET, EERGY EFFICIET, OW DEPTH CETRA EXTRACT SYSTEM. SAP Q RECOGISED. TE CHI C A I FORM AT IO B E E F I T S MEETS BUIDIG REGUATIOS SAP Appendix Q recognised.
More informationCTXA-AS/AT/AW, FTXA-AS/AT/AW
Split Air Conditioning Technical Data CTXA-AS/AT/AW, FTXA-AS/AT/AW > CTXAA2V1BS > CTXAA2V1BT > CTXAA2V1BW > FTXAA2V1BS > FTXAA2V1BT > FTXAA2V1BW > FTXAA2V1BS > FTXAA2V1BT > FTXAA2V1BW > FTXAA2V1BS > FTXAA2V1BT
More informationDMC-1000 Chassis-Based Media Converter
DMC-1000 Chassis-Based Media Converter User s Guide Rev. 01 (Jan. 2002) 6012-9600131 (1907MCR11616000) Printed In Taiwan RECYCLABLE i TABLE OF CONTENTS TABLE OF CONTENTS... II PREFACE... 3 19 MEDIA CONVERTER
More informationProduct data sheet accessories control and regulation Accessories AIRWIN
Product data sheet accessories control and regulation BO-CT1 Continuous controller Item no. 6100101 Control of humidification performance BO-CT1 Option board 2 binary inputs Item no. 002212 Setpoint switching,
More informationZB4BA73134 green flush/red projecting/green flush tripleheaded pushbutton Ø22 with marking
Characteristics green flush/red projecting/green flush tripleheaded pushbutton Ø22 with marking Main Range of product Product or component type Device short name Bezel material Mounting diameter Sale per
More information42C/V. Fan Coil Unit Air Flow: 340~2040m 3 /h
2/V Fan oil Unit Air Flow: 0~0m 3 /h arrier hina arrier orporation is a subsidiary of the United Technologies orp. (UT), which ranks the 10th in Fortune Top 00 in and has its operations in aerospace and
More informationRoom sensors QFA4160 QFA41 D AQF4150 AQF3153. Symaro. for relative humidity and temperature with calibration certificates
1 859 1859P01 1859P02 1859P04 QFA4160 QFA41 D AQF4150 AQF3153 Symaro Room sensors for relative humidity and temperature with calibration certificates QFA41 Operating voltage AC 24 V / DC 13.5...3 Signal
More informationXB4BW73731B5 green flush/red projecting illuminated double-headed pushbutton Ø22 1NO+1NC 24V
Product datasheet Characteristics XB4BW73731B5 green flush/red projecting illuminated double-headed pushbutton Ø22 1NO+1NC 24V Complementary Product weight Resistance to high pressure washer Colour of
More informationFilter Fan Unit LIGHT
Filter Fan Unit LIGHT Type LIGHT EC Technical Concept Technical Concept Filter Fan Unit LIGHT Product Description Filter Fan Units (FFUs) from M+W Products are designed to provide clean air to individual
More informationXB5AS8445 red Ø40 Emergency stop, switching off Ø22 trigger latching turn release 1NO+1NC
Characteristics red Ø40 Emergency stop, switching off Ø22 trigger latching turn release 1NO+1NC Main Range of product Product or component type Device short name Bezel material Fixing collar material Mounting
More informationEC centrifugal fan - RadiPac
R3G31-AX54-21 ebm-papst Mulfingen GmbH & Co. KG Bachmühle 2 D-746 Mulfingen Phone +49 7938 81- Fax +49 7938 81-11 info1@de.ebmpapst.com www.ebmpapst.com Limited partnership Headquarters Mulfingen Amtsgericht
More informationSwitches and Indicators 84
Switches and Indicators 84 84 Switches and Indicators Index Series 84 Description Page 177 Product Assembly Page 178 Mounting Instruction Page 179 Product Range - pushbuttons for flush mounting - accessories
More informationMotor protection circuit breakers
Wide adjustment range 0. to 00A IEC breaking capacity Icu 50kA (400V) up to 00A Suitable for isolation Comprehensive line of accessories Magnetic-only version Automatic trip indicators High reliability
More informationON/OFF HUMIDIFIER CONTROL (ROOM 0R DUCT SENSOR) WITH OUTDOOR TEMPERATURE RESET OVERVIEW WALL CONTROLLER INSTALLATION (TCY-BH-T-U)
(ROOM 0R DUCT SENSOR) WITH OUTDOOR TEMPERATURE RESET TCY-BH-T-U Wall controller with sensor TDC-BH-T-U Duct controller with sensor SOA-Tn10 Outdoor temperature sensor (Optional) OVERVIEW For wall applications
More informationFree Energy Band RCC30U Room Temperature Controller for Four-pipe Fan Coil Unit
Document No. 155-324 Free Energy Band RCC30U Room Temperature Controller for Four-pipe Fan Coil Unit Description Features Application Product Number Room temperature controller for four-pipe fan coil units.
More informationMillenium II +: general characteristics
Millenium II +: general characteristics Starter kit Blind Temperature sensors Special starter kits Bare board Power supply Level detection Local extensions Accessories Standard Expandable Adjacent extensions
More informationMechanically Activated Device for Dry Run Protection in Applications with LORENTZ Solar Pump Systems
Well Probe Mechanically Activated Device for Dry Run Protection in Applications with LORENTZ Solar Pump Systems The switch can be used to detect the water level within a well. When the water level in the
More information5 imple reasons to switch
5 imple reasons to switch BELANKO TM / NEW RANGE OF WIRING DEVICES 5imple reasons to switch to belanko tm With Belanko TM, simplicity is beauty. Now, discover 5 good reasons why Belanko TM should be your
More informationAIR COOLED CONDENSERS
AIR COOLED CONDENSERS NQAC Quiet Line HNSQAC NQAC Quiet Line kw () Highly efficient external rotor fan motors give optimum performance with low noise levels Multiple fans (on all except smallest models)
More informationDIN Series MINIATURE CIRCUIT BREAKERS, RESIDUAL CURRENT CIRCUIT BREAKERS. Introducing the DIN Series High-quality, high-performance circuit breakers
DIN Series MINIATURE CIRCUIT BREAKERS, RESIDUAL CURRENT CIRCUIT BREAKERS Introducing the DIN Series High-quality, high-performance circuit breakers Features (1) All models fully comply with IEC regulations
More informationSensors with analog output
Inductive sensors with analog output provide a current, voltage or frequency signal and are ideally suited for simple control tasks. They are used in many applications, requiring more than just simple
More informationC5 Series Stainless Steel Photoelectric
C5 Series Stainless Steel Photoelectric Part Number Sensing Range M5 (5 mm) stainless steel - DC 14 models available Diffuse and through-beam styles Long operating distances Compact stainless steel housing
More informationAPS4 Inductive Proximity Sensors
APS4 Inductive APS4-S-E-D APS4-S-E2-D APS4-M-E-D APS4-M-E2-D Compact x27 mm plastic DC 4 models available Compact polycarbonate housing; comes with mounting plate High-frequency oscillation type DC 3-wire,
More informationDesk Grommet Number(s) : to 52, to 58, to 63,
87045 LIMOGES Cedex Phone : 05 55 06 87 87 Fax : 05 55 06 88 88 Desk Grommet Number(s) : 0 540 50 to 52, 0 540 55 to 58, 0 540 60 to 63, CONTENTS PAGES 1.Range 1 to 3 2.Installation 4 to 9 3.Technical
More informationIGLOO IGLOO EASY INSTRUCTION MANUAL
ENGLISH EASY C695 C698 INSTRUCTION MANUAL PRELIMINARY Congratulations on choosing a Clay Paky product! We thank you for your custom. Please note that this product, as all the others in the rich Clay Paky
More informationXB4BW73731B5 green flush/red projecting illuminated doubleheaded pushbutton Ø22 1NO+1NC 24V
Product data sheet Characteristics XB4BW73731B5 green flush/red projecting illuminated doubleheaded pushbutton Ø22 1NO+1NC 24V Product availability : Stock - Normally stocked in distribution facility Price*
More informationFerrous metal (The sensing distance decreases with non-ferrous metal.) Power supply voltage (operating voltage range)
Description The sensors provide excellent results even with difficult-to-detect objects, e.g. small or thin parts, wires or bright metals. A variety of types cover a wide range of individual requirements
More informationSafety. Features 1 ID: Make all the connections before you plug in the main power. DMX512 Controllable and RDM Configurable
Features DMX512 Controllable and RDM Configurable Designed for driving LED strips through 6 high power 12 and 24 Volts output units available Easy addressing interface (physical switches and RDM) Isolated
More informationPDS100 Programmable Dispensing System SAFETY INSTRUCTIONS
PDS100 Programmable Dispensing System INSTRUCTION MANUAL SAFETY INSTRUCTIONS Before using any Fluid Metering, Inc. product read the following safety instructions as well as specific product specifications
More informationXB4BK123B5. Product data sheet Characteristics. Complete illuminated selector switch. position stay put 1NO+1NC 24V. Main.
Characteristics green complete illuminated selector switch Ø22 2- position stay put 1NO+1NC 24V Main Range of product Product or component type Device short name Bezel material Fixing collar material Mounting
More informationEMC1600 Series Media Converter and Ethernet Extender Chassis
EMC1600 Series Media Converter and Ethernet Extender Chassis User s Manual Preface This manual describes how to install and use the 16-Bay Media Converter and Ethernet Extender Chassis. This chassis is
More informationVFC. Operating manual TROX air terminal units Type VFC volume flow controllers. General information 2. VFC series volume flow controllers
Type volume flow controllers series volume flow controllers General information Correct use Safety notes Area of application Operating modes Product description Installation 4 Commissioning and wiring
More informationZB5AA46 red recessed pushbutton head Ø22 spring return unmarked
Product data sheet Characteristics ZB5AA46 red recessed pushbutton head Ø22 spring return unmarked Complementary CAD overall width CAD overall height CAD overall depth Product weight Mechanical durability
More informationPower Supply and Fan Module Installation
3 CHAPTER This chapter describes how to remove and install a new or replacement power supply or fan module in a Catalyst 3750-E or Catalyst 3560-E switch. See these sections: Installation Overview, page
More informationRoom Temperature Controller
3 023 Room Temperature Controller for four-pipe fan coil units RCC30 Outputs for on / off valve actuators Outputs for three-speed fan Control depending on room or return air temperature Operating modes:
More informationDEFINE XL COMPUTER DEFINE XL COMPUTER CASE CASE
DEFINE XL COMPUTER DEFINE XL COMPUTER CASE CASE USER S MANUAL 1.1 Thank you and congratulations on your purchase of your new Fractal Design Define XL ATX Computer Case! Before using the case, please take
More informationVORTICE VARIO RANGE IPX4 LONG LIFE
VORTICE VARIO RANGE EXTRACT AND INTAKE AXIAL FANS SUITABLE FOR AIR EXTRACTION DIRECTLY TO THE OUTSIDE OFFERING A WIDE VARIETY OF INSTALLATION POSSIBILITIES IPX4 LONG LIFE 30.000 h VENTILATION AIR CONDITIONING
More informationkyalfa V- VDD/VDD6 General Contents
General Contents. kyalfa V- VDD/VDD6 ky General Contents General Features A dry cooler is a forced convection air-cooled fluid cooler, designed for outdoor installation. Air is forced over the finned coil
More informationZB5AV03 green pilot light head Ø22 plain lens for BA9s bulb
Characteristics green pilot light head Ø22 plain lens for BA9s bulb Complementary CAD overall width CAD overall height CAD overall depth Product weight Station name Electrical composition code Environment
More informationTechnical data sheets
echnical data sheets Ready-to-connect spring return actuator with emergency function for VAV and CAV units in ventilation and air conditioning systems in buildings For air dampers up to approx. 4 m 2 orque
More informationAMP-TWIST* 6S Series SL Jack
Product Specification 108-93003 16/Mar/2011 Rev E AMP-TWIST* 6S Series SL Jack 1. SCOPE 1.1 Content This specification covers performance, tests and quality requirements for AMP NETCONNECT*, AMP- TWIST*
More informationML7421A,B Electric Linear Valve Actuators
ML7421A,B Electric Linear alve Actuators FEATURES Quick and easy installation No separate linkage required No adjustments Force-limiting end switches Manual operator Synchronous motor Corrosion-resistant
More informationUC102 basic version with display and knob UC102BL version with display, knob and backlight UC102DK version without knob and display
UC102 Communicative heating controller Summary UC102 is a communicative room heating controller with two inputs and one PWM output for control of a radiator or electrical heater. It can work autonomously,
More informationHow to Design Custom Enclosures for Motherboard-Based Systems
PROTOCASE TECHNICAL BULLETIN How to Design Custom Enclosures for Motherboard-Based Systems (covering ATX and Mini ITX form factors) Document Edition - 1 Last Updated: June 6 th,2011 Protocase, Inc. All
More informationVariable Flow Rate Control Unit
VAV Produktdata TEKNISK DOKUMENTATION VENTILATION BG BURCHARTH A/S Variable Flow Rate Control Unit Model BVAV-R: VAV unit that has circular section. BVAV-RS: VAV terminal unit. BVAV-Q: VAV unit that has
More informationRevo 120. User Manual
Revo 120 User Manual GENERAL INFORMATION Congratulations, you have just purchased one of the most innovative and reliable lighting fixtures on the market today! The Revo 120 has been designed to perform
More informationINSTRUCTION MANUAL HIGH CURRENT DRIVER BOARD STAND ALONE
Instruction Manual High Current Driver Board Stand Alone 1 INSTRUCTION MANUAL HIGH CURRENT DRIVER BOARD STAND ALONE Models: 1 AMP: HCDBSA1_0AMP 1.5 AMP: HCDBSA1_5AMP 2.0 AMP: HCDBSA2_0AMP 2.5 AMP: HCDBSA2_5AMP
More informationZB5AV043 red pilot light head Ø22 plain lens for integral LED
Product datasheet Characteristics ZB5AV043 red pilot light head Ø22 plain lens for integral LED Complementary CAD overall width CAD overall height CAD overall depth Product weight Station name Electrical
More informationZB5AH1 white projecting pushbutton head Ø22 push-push unmarked
Characteristics white projecting pushbutton head Ø22 push-push unmarked Main Range of product Product or component type Device short name Bezel material Mounting diameter Head type Sale per indivisible
More information