Cross hairs for vertical and horizontal profiles. Profile can be linked to cross hair position, centroid, peak or sum profile can be displayed
|
|
- Corey Blankenship
- 5 years ago
- Views:
Transcription
1 3.1.2 Laser Beam Analysis Systems BeamStar Greatest ease of use Automated operation Effortless report generation Start/stop measurement Background subtraction for improved accuracy measurements Beam Wander screen Cross hairs for vertical and horizontal profiles. Profile can be linked to cross hair position, centroid, peak or sum profile can be displayed 3D display can be rotated or angled at will. Mouse button-shift moves image, mouse button-alt sizes image. A wealth of display choices are available in the menu When laser power is entered, the vertical profile graph is shown in meaningful units of W/cm2 Profile graph shows profile chosen in the 2D display. Flexible system allows user to open as many profile screens as desired and choose X and/or Y profile or sum profile for each. Shown is the Gaussian fit screen. A top hat fit screen can also be shown Origin is centered on CCD center location for ease of use Add button to add additional screens. This flexible system allows user to customize screen Description of Other Control Pages and Functions Setup for photodiode triggering with no need for connection to laser Pre trigger allows automatic synchronization with even subnanosecond laser pulses Automated or manual shutter, gain and background control All numerical values are shown in this compact screen. Note close agreement between 3 different measures of beam width in this unretouched measurement of a HeNe laser. Tailor digital camera format to needs in terms of effective pixel area, dynamic range and pixel density. This allows optimum use of resolution and speed For pulsed lasers, setup for external electrical trigger or exclusive photodiode self triggering Choose to display line or sum profiles With line profiles choose from 3 different reference points or numerical control User can click on this and enter laser power. BeamStar will subsequently follow power correctly Choose whether profile will be x, y or both and whether to align to xy axis or profile axis For latest updates please visit our website:
2 Top Hat Function Choose which results you wish to display Pass / Fail Choose X or Y profile Available for all functions with numerical results. Click on pass/fail and open dialog box Pass / Fail: values selected in dialog box will show green if pass and red if fail Top Hat: Choose boundaries for analysis Major/Minor Axes Alignment and Other Features Measure the distance from any point to any other point by right clicking on the mouse at the first point, moving to second point then right clicking again. Mark the position of the peak and centroid on the 2D display Display can be set to align automatically with major/minor axes of image as well as XY. Region of Interest A region of interest can be selected and then all calculations and pictures will refer only to the selected area. Note how in the picture on the left, the beam width values are meaningless because of the two separate beams while on the right, with region of interest, we get good readings for the beam selected. The region of interest can also be used to reduce background noise from surrounding areas for small beam and increase measurement accuracy. For latest updates please visit our website:
3 Beam Wander Screen This sophisticated and easy to use beam wander function allows you to track and record laser beam movement with time. Choose time limit for measurement Summary of data shown each period in log file Concurrent with screen, log data to file in csv or text format Record data in microns or input distance from source and measure in microradians For latest updates please visit our website:
4 Camera Compatibility For lasers between nm wavelenghts, BeamStar interfaces to silicon CCD USB cameras. Interface USB USB FireWire FireWire Camera Compatability SP503 SP620 FX50 (LEGACY) FX33 (LEGACY) Specifications BeamStar Features Overview Applications where ease of use is most important Operates in either manual setup or Auto-exposure modes Quantitative measurements, many ISO cpmpliant Limited statistical results Supports the FX (Firewire) and SP (USB 2.0) lines of cameras Simultaneous 2D and 3D displays Single instance single camera use Standard child window design Fixed 2D zoom settings, continuous 3D scaling Limited ROI support Manual Aperturing Pass-Fail on most results items, not including statistics Beam Pointing Stability scatter chart and results Logging limited to results only Proprietary data file format Somewhat configurable Report Generation using MHT format Limited ActiveX controls with data and results access ActiveX sample library for LabVIEW, VB6 and VB.NET Closed application Windows XP SP2 and Vista-32 compatible Quantitative Calculations; Basic Results (per ISO 11145, /-3) Power/Energy Results Total power (Can be calibrated to an external power meter) Spatial Results Divergence Gaussian Fit Tophat Results Other Quantitative Items Beam Stability Displays and Results Peak to average Peak and Centroid locations Beam width )Second Moment (D4s Knife Edge 90/10 of peak 50% & 13.5% Beam diameter Elliptical Results Elliptical orientation Ellipticity Distance Measurement Multiple Manually drawn ruler lines on 2D display 1D line fits Height Radius, Width, FWHM Correlation of fit Peak to Average Modulation 2D and 1D Tophat Fit Effective Area Effective Diameter Tophat Mean Tophat Deviation Std Dev/Mean 1D surface inclination Frame Averaging Frame Reference Subtraction Camera signal/noise calculator Row and Column summing with results, printable Pointing Stabilty (Beam Wander) of Centroid Scatter Plot display Last Centroid Mean Centroid Centroid Std Dev Distance to Mean Centroid Maximum wander Auto scaling Sample/Time controlled For latest updates please visit our website:
5 Specifications Beam Profile Display Options 1D Features 2D Features 3D Features Statistical Analysis File types Printing Pass/Fail Logging Exporting Automation Interface (.NET) Integrated Help Signal Conditioning for Enhanced Accuracy Frame Averaging Frame Summing Convolution (Adjacent Pixel Averaging) Camera Features Camera related features in the applications Trigger, Capture and Synchronization Methods BeamStar Can open multiple 2D and 3D display windows 2D and 3D may render in different colors Can open X and/or Y 1D beam slice profiles in separate windows. Continuous software zooming in both 1D and 3D displays but fixed scaling in 2D displays Pan to any detector location Single rainbow color palette, different in 2D and 3D Separte windows for each display and results X any Y plots on separate or combined displays 1D displays with basic results and column row summing option 1D Gaussian fit to the profile with results 1D Tophat results on a line thru a drawn aperture Continuously resizable and preset scaleable child window Beam is always auto scaled to the display palette Multiple Point-to-point distance measurements Adjustable Cursors that can track peak or centroid Crosshair that can track peak, X that can track centroid Adjustable manual aperture (called ROI) Displayed beam width marker Zoom controlled in tab, panning controlled in slider bars Origin fixed at center of display 3D Solid surface Integrated Mouse actuated pan/zoom/tilt/rotate controls Selectable wire frame density User enabled backplanes with beam projections Limited to select results in Tophat and Beam Wander results items Propriatary Data and Setup format Math program and Excel compatable ASCII-csv results files Graphics in jpg, gif, tif, png, bmp Microsoft HTML Format (MHT a single file which shows results, images and BeamStar settings) Images, reports, results, and setup information Single frame printing WYSIWYG images Set Maximum/Minimum limits on most calculations Red/Green font color indication on result items Result Logging Formats:Math program and Excel compatable csv results Beam Wander Results: csv Limited Automation Interface with examples in LabVIEW, VB.NET & VB6 Automate launch and termination of the application Automate the capture of Binary Video Data Automate the acquisition of aplication results PDF Operators Manual Context Sensitive Hints Background Subtraction Frame averaging Black Level Control (manual or auto control) Gain Control (manual or auto control) Exposure Control (manual or auto control) User Programmable ROI Bits per pixel setting External Trigger Input Strobe Output External Trigger Probe Magnification settings Frame buffer settings Enable auto-, exposure/gain/black level 8/10/12 bits per pixel Select Format Measure S/N ratio Trigger modes CW - captures continuously at the camera frame rate Trigger-In from laser Trigger-Out to laser Video Trigger. Display and calculations update only when the camera captures a signal greater than a user set level Capture options Continuous Single shot For latest updates please visit our website:
6 Specifications Video Playback System Requirements BeamStar Video playback with post anaysis User customizable playback rates Whole video file playback looping only Almost all measurements can be performed on video files PC computer w/windows XP Pro, or Vista-32, Laptop or Desktop GHz Pentium style processor Minimum 1GB RAM for XP, 2GB for Vista-32 Plug & Play compatible Hard drive space suitable to hold the amount of video data you expect to store. ( GB recommended) USB2 input Ordering Information Item Description P/N USB2 Beam Profiler Systems (camera and software) BS-USB-SP503 BeamStar software, software license, ½ format 640x480 pixel camera with 4.5mm CCD recess. Comes with SP90153 BS-USB-SP620 USB cable and 3 ND filters BeamStar software, software license, 1/1.8 format 1600x1200 pixel camera with 4.5mm CCD recess. Comes with USB cable and 3 ND filters SP90155 PC Accessories for Cameras USB A-mini B Cable USB Cable with A to mini-b connectors, 5 meter length SP90205 Optical Synch for Pulsed Lasers Optical Trigger for FX and SP Cameras Optical trigger assembly which can be mounted on camera or separately to sense laser pulses and synchronize FX and SP cameras with pulses. Comes with a BNC cable to for mounting on camera and a stand for mounting separately. SPZ17005 For latest updates please visit our website:
Laser Beam Analysis Systems
Laser Beam Analysis Systems BeamGage TM, LBA, and BeamStar TM an Overview The performance of today s laser systems can strongly affect the success of demanding, modern laser applications. The beams size,
More informationBeam Analysis BeamMic TM Basic Laser Beam Analyzer System. BeamMic Main Display Screen
3.3.2 BeamMic TM Basic Laser Beam Analyzer System High-speed false color beam intensity profile displays in both 2D and 3D Operates in Windows 7 and Windows 10 Numerical beam profile analysis employs patented
More informationLaser Beam Profile Laser Beam Analysis Systems BeamGage -Standard BeamGage -Professional BeamGage -Enterprise
3.1.2 Laser Beam Analysis Systems 3.1.2.1 BeamGage -Standard BeamGage -Professional BeamGage -Enterprise User selectable for either best accuracy or ease of use Extensive set of ISO quantitative measurements
More informationBeam Cube. Beam Cube INDUSTRIAL LASER BEAM ANALYZER USER MANUAL. OPHIR OPTRONICS
Beam Cube Beam Cube INDUSTRIAL LASER BEAM ANALYZER USER MANUAL OPHIR OPTRONICS www.ophiropt.com Rev B1.31-U2.30-1 March-12-2008 Initial Revision Beam Cube User Guide Introduction Contents 1 Introduction...
More informationBeam Profile Wavelength Temporal Profile
Beam Profile Wavelength Temporal Profile 86 BeamStar FX Firewire CCD Laser Beam Profilers BeamStar FX 66 BeamStar FX 66 ⅔" Camera BeamStar FX 50 BeamStar FX 50 with Photodiode trigger BeamStar FX 50 ½"
More informationBeam Analysis BeamGage -Standard Version
3.3.1 3.3.1.1 BeamGage -Standard Version Extensive set of ISO quantitative measurements Patented Ultracal algorithm for highest accuracy measurements in the industry Customizable user interface for ease
More informationBeam Analysis BeamGage -Standard Version
3.2.1 3.2.1.1 BeamGage -Standard Version Extensive set of ISO quantitative measurements Patented Ultracal algorithm for highest accuracy measurements in the industry Customizable user interface for ease
More informationBeam Profilier - Beamage 3.0
Profilier - age 3.0 KEY FEATURES High resolution (160x120 points) 2.2 MPixels resolution gives accurate profile measurements on very small beams Large Area The 11.3 x 6.0 mm sensor allows to measure very
More informationTABLE OF CONTENTS PRODUCT DESCRIPTION VISUALIZATION OPTIONS MEASUREMENT OPTIONS SINGLE MEASUREMENT / TIME SERIES BEAM STABILITY POINTING STABILITY
TABLE OF CONTENTS PRODUCT DESCRIPTION VISUALIZATION OPTIONS MEASUREMENT OPTIONS SINGLE MEASUREMENT / TIME SERIES BEAM STABILITY POINTING STABILITY BEAM QUALITY M 2 BEAM WIDTH METHODS SHORT VERSION OVERVIEW
More informationBA500 - V2 Industrial Laser Beam Analyzer BA500 - V2 USER MANUAL. OPHIR OPTRONICS
BA500 - V2 BA500 - V2 Industrial Laser Beam Analyzer USER MANUAL OPHIR OPTRONICS www.ophiropt.com rev B1.31-U2.30-1/14.08.08/eg New (BA500-V2 replacing BA500-V1) Introduction Contents 1 Introduction...
More informationCompact, Portable, Port-Powered, USB 2.0 Beam Profiling
Advancing the Technology of Laser Analysis Laser Beam Profilers WinCamD -UCM 2/3 CMOS WinCamD -UHR High Resolution 5.2 µm WinCamD -UHS High Speed 140 Hz/25 khz Compact, Portable, Port-Powered, USB 2.0
More informationLaserDec CL - Product Description -
CO 2 LASER BEAM PROFILER LaserDec CL - Product Description - The high performance LaserDec system is based on industry s unique imaging technique. It is designed for monitoring high-power CO 2 -lasers
More informationBeam Analysis Camera Based Beam Propagation Analyzer: M Automatic M 2 - at Production Speeds. Manual M 2
3.7.1 Camera Based Beam Propagation Analyzer: M 2 ISO compliant Automatically measure your beam quality in under 1 minutes Tune your laser for best operation Specifically developed for continuous usage
More informationWinCamD-LCM 1" CMOS Beam Profiling Camera, SuperSpeed USB 3.0, * nm * model-dependent
Datasheet WinCamD-LCM 1" CMOS Beam Profiling Camera, SuperSpeed USB 3.0, 190 1610* nm * model-dependent With an 11.3 x 11.3 mm active area, 4.2 Mpixels, 5.5 x 5.5 μm pixels, optical and electronic triggering
More informationTABLE OF CONTENTS PRODUCT DESCRIPTION CINCAM CCD TECHNICAL DATA SENSOR RESPONSE DIMENSIONS CINCAM CCD LARGE FORMAT TECHNICAL DATA SENSOR RESPONSE
TABLE OF CONTENTS PRODUCT DESCRIPTION CINCAM CCD TECHNICAL DATA SENSOR RESPONSE DIMENSIONS CINCAM CCD LARGE FORMAT TECHNICAL DATA SENSOR RESPONSE DIMENSIONS CINCAM CMOS TECHNICAL DATA SENSOR RESPONSE DIMENSIONS
More informationLatest Innovations Laser Power and Energy Measurement
Laser Power and Energy Measurement BF line of pyroelectric sensors Highest damage threshold coating 800mJ/cm2 for ns pulses Highest damage threshold diffuser 4J/cm2 IR to UV Widest spectral range with
More informationSI-100 Digital Microscope. User Manual
SI-100 Digital Microscope User Manual Read this manual before use Keep for future reference Content 1 Introduction... 3 1.1 About The SI-100... 3 1.2 Advantage of SI-100... 3 1.3 Product Specification...
More informationUsing LoggerPro. Nothing is more terrible than to see ignorance in action. J. W. Goethe ( )
Using LoggerPro Nothing is more terrible than to see ignorance in action. J. W. Goethe (1749-1832) LoggerPro is a general-purpose program for acquiring, graphing and analyzing data. It can accept input
More informationBeamView Analyzer. Laser Beam Diagnostic Systems. Digital and Analog Camera Systems. Refined Windows software
Coherent Auburn Division Instruments Beam Diagnostics BeamView Analyzer Laser Beam Diagnostic Systems Digital and Analog Camera Systems Refined Windows software Extensive selection of laser beam diagnostic
More information4X Beam Expander P/N SPZ17022 and Optional Beam Splitter P/N SPZ17027 User Notes
4X Beam Expander P/N SPZ17022 and Optional Beam Splitter P/N SPZ17027 User Notes Ophir-Spiricon Inc. 60 West 1000 North Logan, UT 84321 For Sales, Service or Technical Support Phone (435) 753-3729 Fax
More informationMANUAL. KEY for DISCOVERIES MOTORISED BEAM EXPANDER 1x - 8x. MEX108 series
MANUAL KEY for DISCOVERIES MOTORISED BEAM EXPANDER 1x - 8x MEX108 series Table of contents Table of contents... 2 1. Safety requirements... 4 2. Operation principle... 5 2.1.Optical design... 5 3. Features
More information2.2 PC Interfaces. Power Meters PC Connectivity Options for Power/Energy Measurement
2.2 PC Interfaces 2.2.1 PC Connectivity Options for Power/Energy Measurement Sample data with Ophir power meter at up to 4000 points per second Ophir power meter capable of on board storage of data of
More informationTABLE OF CONTENTS PRODUCT DESCRIPTION LASERDEC CL200 / CL200HP TECHNICAL DATA DIMENSIONS LASERDEC CL500 / CL500HP TECHNICAL DATA DIMENSIONS
TABLE OF CONTENTS PRODUCT DESCRIPTION LASERDEC CL200 / CL200HP TECHNICAL DATA DIMENSIONS LASERDEC CL500 / CL500HP TECHNICAL DATA DIMENSIONS ACCESSORIES ATTENUATION UNIT 0 ATTENUATION UNIT 90 BEAM REDUCER
More informationLASER BEAM PROFILING SOLUTIONS
LASER BEAM PROFILING SOLUTIONS IR Laser Beam Profiler - LaserDec - DISCONTINUED! UV-NIR Laser Beam Profiler - CinCam - Product Description: CCD / CMOS Technical Data Accessories CinCam Application: Beam
More informationTechnical Specifications for High speed PIV and High speed PIV-PLIF system
Technical Specifications for High speed PIV and High speed PIV-PLIF system MODULE A. HIGH SPEED PIV (3-C) A1. Double Cavity High Speed Laser (up to 10 khz): The vendor should provide Dual Head (DH) laser
More informationElixir Ad-hoc Report. Release Elixir Technology Pte Ltd
Elixir Ad-hoc Report Release 4.0.0 Elixir Technology Pte Ltd Elixir Ad-hoc Report: Release 4.0.0 Elixir Technology Pte Ltd Published 2015 Copyright 2015 Elixir Technology Pte Ltd All rights reserved. Java
More informationSoftware for Observation and Measurement SGMMS V2.6. Users Manual
AFM45-S03-12402 Software for Observation and Measurement SGMMS V2.6 Users Manual SIGMAKOKI Co., LTD. CONTENTS 1 OVERVIEW... - 3-2 BEFORE USE... - 3-2-1 OPERATIONAL ENVIRONMENT...- 3-2-2 INSTALLATION PREPARATION...-
More informationAbout this Guide How the Document is Organized... 5 Definition of Terms Chapter 1 PMManager and Devices... 6
Table of Contents About this Guide... 5 How the Document is Organized... 5 Definition of Terms... 5 Chapter 1 PMManager and Devices... 6 PMManager Features... 6 Package Contents... 6 System Requirements...
More informationInsight: Measurement Tool. User Guide
OMERO Beta v2.2: Measurement Tool User Guide - 1 - October 2007 Insight: Measurement Tool User Guide Open Microscopy Environment: http://www.openmicroscopy.org OMERO Beta v2.2: Measurement Tool User Guide
More informationConvert your laptop or desktop PC into a multichannel power/energy meter. Pulsar-4 operating with StarLab software
2.2.5 Pulsar Multichannel and Triggered USB Interfaces Convert your laptop or desktop PC into a multichannel power/energy meter From sensor to interface to PC 1,2 and 4 channel models Plug and play with
More informationVision MET/METCAD. 2D measurement system
Vision MET/METCAD 2D measurement system September 2012 ~ Contents ~ 1 GENERAL INFORMATION:... 3 1.1 PRECISION AND RESOLUTION... 3 2 GETTING STARTED:... 5 2.1 USER IDENTIFICATION... 5 2.2 MAIN WINDOW OF
More informationElixir Ad-hoc Report. Release Elixir Technology Pte Ltd
Elixir Ad-hoc Report Release 3.5.0 Elixir Technology Pte Ltd Elixir Ad-hoc Report: Release 3.5.0 Elixir Technology Pte Ltd Published 2014 Copyright 2014 Elixir Technology Pte Ltd All rights reserved. Java
More information4. Recommended alignment procedure:
4. Recommended alignment procedure: 4.1 Introduction The described below procedure presents an example of alignment of beam shapers Shaper and Focal- Shaper (F- Shaper) with using the standard Shaper Mount
More informationMotic Images Plus 3.0 ML Software. Windows OS User Manual
Motic Images Plus 3.0 ML Software Windows OS User Manual Motic Images Plus 3.0 ML Software Windows OS User Manual CONTENTS (Linked) Introduction 05 Menus and tools 05 File 06 New 06 Open 07 Save 07 Save
More informationevue Digital Imaging System DATA SHEET FEATURES / BENEFITS
evue Digital Imaging System DATA SHEET The evue digital imaging system is optimized for on-wafer test with Cascade Microtech s probe stations. The revolutionary multi-optical path, multi-camera design
More informationBeamWatch User Guide. For Windows 7 and Windows 10 Version 2.x
BeamWatch User Guide For Windows 7 and Windows 10 Version 2.x For Sales, Service, or Technical Support Phone: (435) 753-3729 Fax: (435) 753-5231 Service Email service@us.ophiropt.com Sales Email sales@us.ophiropt.com
More informationUHD 185 FAQs. Optical System
UHD 185 FAQs System Setup How is a typical setup of the UHD 185? Is a wireless control during flight possible? How do I trigger the image acquisition? What is the power consumption? What are the specs
More informationCinCam CCD - Technical Data -
- Technical Data - SENSOR DATA CCD-1201 CCD-1301 CCD-2301 CCD-2302 Format: 1/2 1/3 2/3 2/3 Active area: 6.5mm x 4.8mm 4.8mm x 3.6mm 9.0mm x 6.7mm 8.5mm x 7.1mm Number of pixel: 1388 x 1038 (1.4MPixel)
More informationHow to Measure Wedge. Purpose. Introduction. Tools Needed
Purpose Optical Wedge Application (OWA) is an add-on analysis tool for measurement of optical wedges in either transmission or reflection. OWA can measure a single part or many parts simultaneously (e.g.
More informationZLog Z6R Altitude Data Recording and Monitoring System
ZLog Z6R Altitude Data Recording and Monitoring System 2014-04-28 Page 1 of 24 Introduction ZLog was designed to provide a lightweight, compact device for measuring and recording altitude over time. It
More informationFeatures. Applications. Beam Profiling Camera Based WinCamD Series
Beam Profiling Camera Based WinCamD Series Features NEW WinCamD LCM 1 CMOS array with 5.5 µm 2, 1, 2, & 4 MPixel Formats available Shutter = No Comet Tailing Update Rate to 50 Hz with new SuperSpeed USB
More informationCal-Bay Systems XY Plotter, Time-Base Recorder, Automated Tester. Users Guide. Rev 3.1
Cal-Bay Systems XY Plotter, Time-Base Recorder, Automated Tester Users Guide Rev 3.1 Contents... 1 Quick Start Guide... 2 Selecting a Test Specification... 3 Clearing Traces... 4 Saving Traces...4 Loading
More informationSTIPlotDigitizer. User s Manual
STIPlotDigitizer User s Manual Table of Contents What is STIPlotDigitizer?... 3 Installation Guide... 3 Initializing STIPlotDigitizer... 4 Project GroupBox... 4 Import Image GroupBox... 5 Exit Button...
More information-Table of Contents- 1. Overview Installation and removal Operation Main menu Trend graph... 13
Thank you for buying Data Analysis Software. In order to use this software correctly and safely and to prevent trouble, please read this manual carefully. Notice 1. No part of this manual can be reproduced
More informationHigh definition digital microscope. visioneng.us/lynxevo
visioneng.us/lynxevo High definition digital microscope Exceptional high resolution 1080p/60fps image quality Intuitive image capture and documentation Stand alone, wireless or PC connectivity High quality
More informationCMOS USORIA. Features
CMOS USORIA A CMOS, 2 Megapixel (1600x1200), 1/2 Inch, Color, USB 2, Triggerable, Rugged, Lightweight, Industrial Vision Camera With a C Mount and Tripod Adapter It is Designed for Inspection, Instrumentation,
More informationIntegrating Machine Vision and Motion Control. Huntron
1 Integrating Machine Vision and Motion Control Huntron 2 System Overview System Overview PXI Color Vision: Cameras, Optics, Lighting, Frame Grabbers and Software Serial 3 Axis Motion Control: Application
More informationTo move cells, the pointer should be a north-south-eastwest facing arrow
Appendix B Microsoft Excel Primer Oftentimes in physics, we collect lots of data and have to analyze it. Doing this analysis (which consists mostly of performing the same operations on lots of different
More informationSample Sizes: up to 1 X1 X 1/4. Scanners: 50 X 50 X 17 microns and 15 X 15 X 7 microns
R-AFM100 For Nanotechnology Researchers Wanting to do routine scanning of nano-structures Instrument Innovators Using AFM as a platform to create a new instrument Educators Teaching students about AFM
More informationFeatures included in isolution Lite, i-solution, isolution DT
Features included in isolution Lite, i-solution, isolution DT Include: Live Measurement and Overlay Settings Users can perform measurements on the live preview image, using the crosshair or grid masks
More informationNOVA. Selected Screens
Displays 70 Ophir smart displays are true plug-and-play instruments. With all head information and calibration stored in the head plug, just plug in any one of over 150 Ophir smart heads and the instrument
More informationv Annotation Tools GMS 10.4 Tutorial Use scale bars, North arrows, floating images, text boxes, lines, arrows, circles/ovals, and rectangles.
v. 10.4 GMS 10.4 Tutorial Use scale bars, North arrows, floating images, text boxes, lines, arrows, circles/ovals, and rectangles. Objectives GMS includes a number of annotation tools that can be used
More informationIMAGE STUDIO LITE. Tutorial Guide Featuring Image Studio Analysis Software Version 3.1
IMAGE STUDIO LITE Tutorial Guide Featuring Image Studio Analysis Software Version 3.1 Notice The information contained in this document is subject to change without notice. LI-COR MAKES NO WARRANTY OF
More informationFemtosecond Single Shot Autocorrelator. Model ASF-20 INSTRUCTION MANUAL
1 Femtosecond Single Shot Autocorrelator Model ASF-20 INSTRUCTION MANUAL 2 The Single Shot Autocorrelator (SSA) Model ASF-20 was designed to monitor the pulsewidth of both oscillators and amplifiers of
More informationStraight from your measuring sensor to your laptop or PC with no cables
2.2.5 Quasar Wireless Bluetooth Interface Straight from your measuring sensor to your laptop or PC with no cables Quasar wireless interface connects to any Ophir sensor and broadcasts to your PC Wireless
More informationTransient Stability Analysis with PowerWorld Simulator
Transient Stability Analysis with PowerWorld Simulator T8: Viewing Transient Stability Results 2001 South First Street Champaign, Illinois 61820 +1 (217) 384.6330 support@powerworld.com http://www.powerworld.com
More informationCreating a Basic Chart in Excel 2007
Creating a Basic Chart in Excel 2007 A chart is a pictorial representation of the data you enter in a worksheet. Often, a chart can be a more descriptive way of representing your data. As a result, those
More informationVisual Physics - Introductory Lab Lab 0
Your Introductory Lab will guide you through the steps necessary to utilize state-of-the-art technology to acquire and graph data of mechanics experiments. Throughout Visual Physics, you will be using
More informationOphir Centauri. High End Portable Laser Power/Energy Meter
Ophir Centauri High End Portable Laser Power/Energy Meter All the functionality you could have wanted in a high-end instrument, packed into a compact meter The Centauri s 7 touch-screen provides ease-of-use
More informationVisionGauge OnLine Spec Sheet
VisionGauge OnLine Spec Sheet VISIONx INC. www.visionxinc.com Powerful & Easy to Use Intuitive Interface VisionGauge OnLine is a powerful and easy-to-use machine vision software for automated in-process
More informationA+ Suite Software. User Manual
A+ Suite Software User Manual 2012.03 Table of Contents Introduction... 1 Minimum System Requirements... 1 Using the A+ Plug-in for PowerPoint... 2 Spotlight... 2 Visor... 3 Setting... 3 Floating Toolbox...
More informationProduct Specifications
Product Specifications The ksa RateRat Pro is a turnkey, real-time, in-situ optical reflectance probe designed for deposition monitoring of semi-absorbent thin films. The RateRat Pro measures deposition
More informationCVI SPECTRAL PRODUCTS. 111 Highland Drive Putnam CT, (860) SM32Pro
CVI SPECTRAL PRODUCTS 111 Highland Drive Putnam CT, 06260 (860) 928-5834 SM32Pro 2.8.28 Table of Contents Warranty and Liability 1 Quick Start Installation Guide 2 System Requirements 3 Requirements for
More informationČesky. Introduction... E-1 Minimum system requirements for PC... E-1 Using the AVerVision Application for PC.. E-3
Table of Contents Introduction... E-1 Minimum system requirements for PC... E-1 Using the AVerVision Application for PC.. E-3 Video Screen... E-3 Control Panel... E-3 Document Camera Control Panel... E-4
More informationComplete High-Speed Motion Capture System
Xcitex Professional Motion System Complete High-Speed Motion Capture System Life Sciences Engineering Manufacturing Automotive Up to 5 hours of continuous recording 5 1000 fps high resolution cameras Synchronize
More informationUV-NIR LASER BEAM PROFILER
- Technical Data - CCD-1201 CCD-2301 CCD-2302 Standard Series Standard Series Standard Series SENSOR DATA Format: 1/2 2/3 2/3 Active area (without cover glass): 6.5mm x 4.8mm 9.0mm x 6.7mm 8.5mm x 7.1mm
More informationAmazing Designs Apps Instruction Manual
Amazing Designs Apps Instruction Manual Amazing Designs Apps is a new embroidery software system from Amazing Designs that contains multiple features, in different toolpacks that are activated separately.
More informationGolden Software, Inc.
Golden Software, Inc. Only $299! The most sophisticated graphing package available, providing the professional quality you need with the flexibility you want. Create one of the more than 30 different graph
More informationASM-IV ARGUS SURFACE METER
ASM-IV ARGUS SURFACE METER The ASM IV instrument was primarily developed for high resolution measurements at the bottom of moving water (ocean/river locations). It records the reflections and the dynamic
More informationThis section provides an overview of the features available within the Standard, Align, and Text Toolbars.
Using Toolbars Overview This section provides an overview of the features available within the Standard, Align, and Text Toolbars. Using toolbar icons is a convenient way to add and adjust label objects.
More informationMobileScan3D. MobileScan3D PlugIn for Geomagic. By Steintek GmbH
MobileScan3D PlugIn for Geomagic MobileScan3D V. 1.0 - Version February, 2006 For Geomagic Qualify 8 SR1 and subsequent releases For Geomagic Studio 8 and subsequent releases By Steintek GmbH Win3DS is
More informationThe CCD-S3600-D(-UV) is a
Advanced Digital High-Speed CCD Line Camera CCD-S3600-D(-UV) USB 2.0 Plug & Play The CCD-S3600-D(-UV) is a complete and ready to use high-speed digital CCD line scan camera. The device includes many advanced
More informationJune 05, 2018, Version 3.0.6
June 05, 2018, Version 3.0.6 VolViCon is an advanced application for reconstruction of computed tomography (CT), magnetic resonance (MR), ultrasound, and x-rays images. It gives features for exporting
More informationHCImage ORCA-Flash4.0 V2 Camera Guide
HCImage ORCA-Flash4.0 V2 Camera Guide Release N/A December 2015 2015 Hamamatsu Corporation. All rights reserved. This guide, as well as the software described in it, is covered under license agreement
More informationezimagex2 User s Guide Version 1.0
ezimagex2 User s Guide Version 1.0 Copyright and Trademark Information The products described in this document are copyrighted works of AVEN, Inc. 2015 AVEN, Inc. 4595 Platt Rd Ann Arbor, MI 48108 All
More informationLASER BEAM PROFILING SOLUTIONS
LASER BEAM PROFILING SOLUTIONS IR Laser Beam Profiler LaserDec Product Description Technical Data Accessories UVNIR Laser Beam Profiler CinCam Product Description Technical Data Accessories CinCam Application:
More informationPRESETTER SP40. Pesaro, September 2013
Pesaro, September 2013 1 PRESETTER SP40 TECHNICAL SPECIFICATIONS: AXIS DIMENSIONS: Diameter 600mm, Height XXXX mm MAIN STRUCTURE: Entirely made in C45 medium carbon steel it ensures greater strength and
More informationSection 33: Advanced Charts
Section 33 Advanced Charts By the end of this Section you should be able to: Use Chart Options Add Moving Averages to Charts Change a 3D Chart View Use Data Labels and Markers Create Stacked Bar Charts
More informationscmos discover new ways of seeing andor.com Features and Benefits Scientific CMOS - Fast, sensitive, compact and light. Specifications Summary
Ultra Sensitive Imaging Low Light Imaging Features and Benefits Compact and light Ideal for integration into space restrictive set-ups 1.2 e - read noise Lower detection limit than any CCD 5.5 megapixel
More informationSpring Semester Study Guide
Spring Semester Study Guide 1. When you create a table in Datasheet view, Access automatically adds a field called ID as the first field in the table. 2. To undo the most recent change to a table structure,
More informationLBP2-SAM Series Beam Sampler for C-mount Cameras. User Notes
LBP2-SAM Series Beam Sampler for C-mount Cameras P/N LBP2-SAM-UV, LBP2-SAM-VIS, LBP2-SAM-IR and LBP2-SAM-BB User Notes Newport Corporation 1791 Deere Avenue Irvine, CA 92606 www.newport.com For Sales,
More informationAdobe Photoshop Sh S.K. Sublania and Sh. Naresh Chand
Adobe Photoshop Sh S.K. Sublania and Sh. Naresh Chand Photoshop is the software for image processing. With this you can manipulate your pictures, either scanned or otherwise inserted to a great extant.
More informationSintec Optronics Technology Pte Ltd 10 Bukit Batok Crescent #07-02 The Spire Singapore Tel: Fax:
Sintec Optronics Technology Pte Ltd 10 Bukit Batok Crescent #07-02 The Spire Singapore 658079 Tel: +65 63167112 Fax: +65 63167113 Measurement of Laser Beam Profile and Propagation Characteristics 1. Laser
More information3D Measurement and Control, Made Easy
3D Measurement and Control, Made Easy WHAT WE DO LMI Technologies is a global leader in 3D scanning, visualization, measurement, and control technology. We focus on developing products to deliver a customer
More informationUser Manual Version 1.1 January 2015
User Manual Version 1.1 January 2015 - 2 / 112 - V1.1 Variegator... 7 Variegator Features... 7 1. Variable elements... 7 2. Static elements... 7 3. Element Manipulation... 7 4. Document Formats... 7 5.
More informationMicrosoft Excel 2007
Microsoft Excel 2007 1 Excel is Microsoft s Spreadsheet program. Spreadsheets are often used as a method of displaying and manipulating groups of data in an effective manner. It was originally created
More informationMake Your Pictures Come to Life with Photo Story 3
Page 1 of 6 Click Here to Install Silverlight United States Change All Microsoft Sites Search Microsoft.com Submit Windows Media Home For Home Windows Media Player Music & Video Cool Devices For Professionals
More informationDASYLab Data Acquisition System Laboratory
Features Create complex applications in minimal time without programming Lets you build worksheets using graphical functions: - Select icons from a palette and place them on worksheet - Connect them using
More informationUser Manual Portable Laptop Console Crash Cart Adapter
User Manual Portable Laptop Console Crash Cart Adapter GUC211V PART NO. M1458 www.iogear.com 2017 IOGEAR. All Rights Reserved. Part No. M1458. IOGEAR, the IOGEAR logo is trademarks of IOGEAR. Microsoft
More informationHigh speed video available for everybody with smart triggers and embedded image processing
High speed video available for everybody with smart triggers and embedded image processing 252 at 640 x 480 direct to PC via USB 2.0 Based on a motherboard with a Spartan 3 FPGA, a fast SRAM and a USB
More informationIMAGING SOFTWARE. Image-Pro Insight Image Analysis Made Easy. Capture, Process, Measure, and Share
IMAGING SOFTWARE Image-Pro Insight Image Analysis Made Easy Capture, Process, Measure, and Share Image-Pro Insight Image Analysis Made Easy Capture, Process, Measure, and Share Image-Pro Insight, the latest
More informationPowerMax-Pro kw Sensors
PowerMax-Pro kw Sensors 1W to 3 kw PowerMax-Pro laser detectors have been enhanced to enable multi-kw continuous power measurement of laser beams. PowerMax-Pro detectors, first introduced in 2014, are
More informationFUTEK USB Software Version User s Manual
FUTEK USB Software Version 2.0.0.0 User s Manual 10 Thomas, Irvine, CA 92618, USA Toll Free: (800) 23-FUTEK Telephone: (949) 465-0900 Fax: (949) 465-0905 futek@futek.com www.futek.com 2 Table of Contents
More informationSpiso-3D operation manual (US Patent 8,077,945 B2)
Spiso-3D operation manual (US Patent 8,077,945 B2) Section 1. Introduction : Spiso-3D is an automated software calculating optical 3D images of neurons mathematically to analyze dendrites and spines (=
More informationTechnology Assignment: Scatter Plots
The goal of this assignment is to create a scatter plot of a set of data. You could do this with any two columns of data, but for demonstration purposes we ll work with the data in the table below. You
More informationksa ICE - Integrated Control for Epitaxy
Introduction The k-space Integrated Control for Epitaxy system (ksa ICE) is a modular in-situ metrology tool designed for today s MOCVD reactors. It combines proven ksa MOS, ksa BandiT, and ksa RateRat
More informationVisual Physics Introductory Lab [Lab 0]
Your Introductory Lab will guide you through the steps necessary to utilize state-of-the-art technology to acquire and graph data of mechanics experiments. Throughout Visual Physics, you will be using
More informationTutorial: Instantaneous Measurement of M 2 Beam Propagation Ratio in Real-Time
Tutorial: Instantaneous Measurement of M 2 Beam Propagation Ratio in Real-Time By Allen M. Cary, Jeffrey L. Guttman, Razvan Chirita, Derrick W. Peterman, Photon Inc A new instrument design allows the M
More informationCamera control software GigaCam
Camera control software GigaCam Operation Manual Version 1.06 CONTENTS 1. Starting the software... 3 2. Discovery the Camera... 4 3. Open the Camera... 5 4. Image setting... 6 5. Acquisition start / stop...
More informationSoftware for Editing and Managing Images CAMEDIA Master 4.2/Pro. Operating Instructions
Software for Editing and Managing Images CAMEDIA Master 4.2/Pro Operating Instructions SE Table of Contents Introduction... 5 Note... 5 Trademarks... 5 Intellectual property rights... 5 Purchasing the
More information