Universal SAS and ACP Cabling Guide

Size: px
Start display at page:

Download "Universal SAS and ACP Cabling Guide"

Transcription

1 IM System Storage N series Universal SS and P abling Guide G

2

3 ontents Preface v Supported features v Websites v Getting information, help, and service vi efore you call vi Using the documentation vi Hardware service and support vi Firmware updates vii How to send your comments vii SS cabling for new storage systems SS cabling rules General SS cabling rules Onboard SS port rules Shelf-to- connection rules ontroller-to--connection rules ontroller-to-controller rule (N3150, N3220, and N3240 system models only) abling SS connections ompleting the SS cabling worksheet SS cabling worksheet rules and template Sample SS cabling worksheet for a N6200 series Sample SS cabling worksheet for an H pair (non N6200 series, N3150, N3220, and N3240, or N3400 ) abling SS ports SS cabling examples Examples of SS cabling for H pairs with quad-port Hs Examples of SS cabling for single-controller configurations with quad-port Hs Examples of SS cabling for N6200 series systems Examples of SS cabling for N3150, N3220, and N3240 system models Examples of SS cabling for N3600 systems Examples of SS cabling for N3400 systems P cabling for new storage systems P cabling rules General P cabling rules P connectivity rules abling P connections abling P on systems with external SS storage abling P on systems with no external SS storage P cabling examples Examples of P cabling for H pairs Examples of P cabling for single-controller configurations P cabling examples for all single-controller configurations except N3400 systems P cabling examples for single-controller N3400 systems Examples of P cabling for N3150, N3220, and N3240 system models with no external storage 57 opyright IM orp iii

4 Glossary ocument update record opyright and trademark information Trademark information Notices iv IM System Storage N series: Universal SS and P abling Guide

5 Preface Supported features IM System Storage N series storage systems are driven by Netpp ata ONTP software. Some features described in the product software documentation are neither offered nor supported by IM. Please contact your local IM representative or reseller for further details. Information about supported features can also be found on the N series support website (accessed and navigated as described in Websites). Websites IM maintains pages on the World Wide Web where you can get the latest technical information and download device drivers and updates. The following web pages provide N series information: v listing of currently available N series products and features can be found at the following web page: v The IM System Storage N series support website requires users to register in order to obtain access to N series support content on the web. To understand how the N series support web content is organized and navigated, and to access the N series support website, refer to the following publicly accessible web page: This web page also provides links to utosupport information as well as other important N series product resources. v IM System Storage N series products attach to a variety of servers and operating systems. To determine the latest supported attachments, go to the IM N series interoperability matrix at the following web page: v For the latest N series hardware product documentation, including planning, installation and setup, and hardware monitoring, service and diagnostics, see the IM N series Information enter at the following web page: publib.boulder.ibm.com/infocenter/nasinfo/nseries/index.jsp opyright IM orp v

6 Getting information, help, and service If you need help, service, or technical assistance or just want more information about IM products, you will find a wide variety of sources available from IM to assist you. This section contains information about where to go for additional information about IM and IM products, what to do if you experience a problem with your IM N series product, and whom to call for service, if it is necessary. efore you call efore you call, make sure you have taken these steps to try to solve the problem yourself: v heck all cables to make sure they are connected. v heck the power switches to make sure the system is turned on. v Use the troubleshooting information in your system documentation and use the diagnostic tools that come with your system. v Refer to the N series support website (accessed and navigated as described in Websites) for information on known problems and limitations. Using the documentation The latest versions of N series software documentation, including ata ONTP and other software products, are available on the N series support website (accessed and navigated as described in Websites). urrent N series hardware product documentation is shipped with your hardware product in printed documents or as PF files on a documentation. For the latest N series hardware product documentation PFs, go to the N series support website. Hardware documentation, including planning, installation and setup, and hardware monitoring, service, and diagnostics, is also provided in an IM N series Information enter at the following web page: publib.boulder.ibm.com/infocenter/nasinfo/nseries/index.jsp Hardware service and support You can receive hardware service through IM Integrated Technology Services. Visit the following web page for support telephone numbers: vi IM System Storage N series: Universal SS and P abling Guide

7 Firmware updates IM N series product firmware is embedded in ata ONTP. s with all devices, ensure that you run the latest level of firmware. ny firmware updates are posted to the N series support website (accessed and navigated as described in Websites). Note: If you do not see new firmware updates on the N series support website, you are running the latest level of firmware. Verify that the latest level of firmware is installed on your machine before contacting IM for technical support. How to send your comments Your feedback helps us to provide the most accurate and high-quality information. If you have comments or suggestions for improving this document, please send them by to starpubs@us.ibm.com. e sure to include the following: v Exact publication title v Publication form number (for example, G ) v Page, table, or illustration numbers v detailed description of any information that should be changed Preface vii

8 viii IM System Storage N series: Universal SS and P abling Guide

9 SS cabling for new storage systems For new storage system installations, you must understand the cabling rules before cabling the SS connections for the disk shelves. Note: abling information for hot-adding or replacing SS disk shelves is in the Installation and Service Guide for your disk model on the N series support website (accessed and navigated as described in Websites) at SS cabling rules You can cable SS disk shelves to storage systems that have SS Hs and/or onboard SS ports by applying the SS cabling rules. General SS cabling rules You need to know the general SS cabling rules governing supported configurations, cables, and SS port connections on the disk shelves. v ll H pair configurations must use multipath H, with the following exceptions: N3400 systems use single-path H. N3150, N3220, and N3240 system models with no external SS storage can use single-path H, which requires no external cabling. However, the recommended configuration is to enable multipath H for the internal disks by connecting the SS ports of one controller module to the SS ports of the partner. Note: When a filer is ordered without external shelves, the two QSFP SS cables and an P cable, required to enable multipath H configuration, can be ordered as F However, if the filer is ordered with external shelves, the cables will come with external shelves instead. Note: multipath H configuration having external shelves requires two ports on each controller for each stack of disk shelves. Even if the stack consists of one disk, two ports on each controller are required. v ll single-controller configurations must use dual-path, with the following exceptions: N3400 systems use single-path. N3150, N3220, and N3240 system models have the internal disks cabled as single-path, but the system can use either single-path or dual-path connectivity to the external shelves; both are supported. opyright IM orp

10 ual-path provides greater resiliency, but when dual-path is used, ata ONTP 8.1.x issues occasional warnings to the console because mixed paths are detected. To avoid the warnings, single-path connections to the external SS storage are a supported option in these configurations. v ables used for SS connections include the following: QSFP to QSFP SS cables are used to connect disk shelves together and to connect disk shelves to the SS ports on the controller. The following illustration shows the QSFP cable connector: QSFP to mini-ss cables are used for N3600 configurations only, and connect disk shelves to the dual-port mini-ss Hs on the controller. The following illustration shows the QSFP to mini-ss cable connectors: v SS ports on the disk are designated by a square symbol or a circle symbol. Square ports are always cabled to circle ports, and circle ports are always cabled to square ports. Never cable square ports to square ports or circle ports to circle ports. The following illustration shows square and circle port labeling on an IOM. IOM P SS Onboard SS port rules Storage systems that have controllers with onboard SS ports must follow a specific port identification rule. For all systems except N3400, an onboard H is defined as occupying PI slot 0, with each port named with sequentially increasing letters (0a, 0b, 0c, and so on). This is to ensure that the SS cabling rules apply to all SS Hs on a controller, whether in a physical PI slot (slot 1-N) or on board the base controller. 2 IM System Storage N series: Universal SS and P abling Guide

11 The following example shows a controller with one onboard SS H in slot 0 and three SS Hs in physical PI slots 1, 2, and 3. Slot 0 Slot 2 Slot 3 For N3400 systems, the onboard SS port labeled 0d should be treated as if it were slot 0 port a. Treating the port as 0a enables you to apply all the SS cabling rules. (ata ONTP continues to recognize this port as 0d.) The following example shows the N3400 exception: 2040 controller 0a 0d Shelf-to- connection rules When you have more than one disk in a stack of disk shelves, the shelves in the stack must be connected to each other (daisy-chained). The disk shelves are daisy-chained in the following way: v IOM circle port is connected to the next IOM square port. v IOM circle port is connected to the next IOM square port. Note: Square ports are always cabled to circle ports, and circle ports are always cabled to square ports. Never cable square ports to square ports or circle ports to circle ports. The following illustration shows a daisy-chained stack of disk shelves with the IOMs arranged side-by-side, similar to how a EXN3500 disk is oriented. SS cabling for new storage systems 3

12 Stack of three shelves P SS P SS IOM IOM The following illustration shows a daisy-chained stack of disk shelves with the IOMs arranged one above the other, similar to how a EXN3000 disk is oriented. Stack of three shelves P SS IOM IOM ontroller-to--connection rules Each controller connects to each stack of disk shelves in the system through the controller SS ports. These ports can be,,, and, and can be on a SS H in a physical PI slot (slot 1-N) or on board the base controller. ontrollers connect to the first and last shelves in a stack. ontroller ports and connect to the first in a stack and controller ports and connect to the last in a stack. For quad-port SS Hs, the controller-to- connection rules ensure resiliency for the storage system based on the SI chip design. Ports and are on one SI chip, and ports and are on a second SI chip. y using ports and to connect to the first in each stack, and using ports 4 IM System Storage N series: Universal SS and P abling Guide

13 and to connect to the last in each stack, the controllers maintain connectivity to the disk shelves if an SI chip fails. The following illustration shows a quad-port SS H with the two SI chips and their designated ports: Quad-port SS H PI-e chip SI chip SI chip port port port port and port connections v ontroller SS ports and are connected to the first disk square port in each stack of disk shelves. The and ports on controller 1/ connect to IOM. The and ports on controller 2/ connect to IOM. For example, the following illustration shows how controller ports and are connected for disk shelves that have the IOMs arranged side-by-side, similar to how a EXN3500 disk is oriented: ontroller 1/ ontroller 2/ Stack 1 Stack 2 P SS P SS P SS P SS IOM IOM IOM IOM For example, the following illustration shows how controller ports and are connected for disk shelves that have the IOMs arranged one above the other, similar to how a EXN3000 disk is oriented: SS cabling for new storage systems 5

14 ontroller 1/ ontroller 2/ Stack 1 P SS Stack 2 P SS IOM IOM v ontroller SS ports and are connected to the disk stacks in sequential order of the PI slots (slot 0, slot 1, slot 2, and so on) on the controller. For example, a controller with slots 1, 2, and 3 occupied with quad-port SS Hs is cabled in order of slots and ports 1a, 2a, 3a, 1c, 2c, 3c: ontroller Slot 2 Slot 3 For example, a controller with slots 0, 1, and 2 occupied (slot 0 being an onboard port and slot 1 and 2 being quad-port SS Hs) is cabled in order of slots and ports 0a, 1a, 2a, 1c, 2c: ontroller Slot 0 Slot 2 6 IM System Storage N series: Universal SS and P abling Guide

15 and port connections v ontroller SS ports and are connected to the last disk circle port in each stack of disk shelves. The and ports on controller 1/ connect to IOM. The and ports on controller 2/ connect to IOM. For example, the following illustration shows how controller ports and are connected for disk shelves that have the IOMs arranged side-by-side, similar to how a EXN3500 disk is oriented: ontroller 1/ ontroller 2/ Stack 1 Stack 2 P SS P SS P SS P SS IOM IOM IOM IOM For example, the following illustration shows how controller ports and are connected for disk shelves that have the IOMs arranged one above the other, similar to how a EXN3000 disk is oriented: SS cabling for new storage systems 7

16 ontroller 1/ ontroller 2/ Stack 1 P SS IOM IOM Stack 2 P SS v ontroller SS ports and are connected to the disk stacks by offsetting the order of the PI slots by one so that the first port on the first slot is cabled last. The cabling offset ensures system resiliency. For example, a controller with three quad-port SS Hs in slots 1, 2, and 3 is cabled in order of slots and ports 2b, 3b, 1d, 2d, 3d, 1b: ontroller Slot 2 Slot 3 For example, a controller with slots 0, 1, and 2 occupied (slot 0 being an onboard port and slot 1 and 2 being quad-port SS Hs) is cabled in order of slots and ports 1b, 2b, 1d, 2d, 0b: 8 IM System Storage N series: Universal SS and P abling Guide

17 ontroller Slot 0 Slot 2 controller with one quad-port H is cabled in order of port 1d and then 1b: ontroller 1/ Stack cabling sequence ontrollers are cabled to the stacks in sequence of the stacks, such as stack 1, stack 2, stack 3, and so on. N3400 configurations For single-controller N3400 configurations, the controller is in Slot (the bottom slot); therefore, the controller is cabled as if it were controller 2/. If a second controller is added to make this an H pair configuration, the new controller is cabled as controller 1/. ontroller-to-controller rule (N3150, N3220, and N3240 system models only) On N3150, N3220, and N3240 system models in H pairs with no external storage, external cables should connect the SS ports on the two controller modules to enable multipath H for the internal disks. Note: When a filer is ordered without external shelves, the two QSFP SS cables and an P cable, required to enable multipath H configuration, can be ordered as F However, if the filer is ordered with external shelves, the cables will come with external shelves instead. SS cabling for new storage systems 9

18 abling SS connections abling the SS connections involves completing the SS cabling worksheet to identify the SS ports that need to be cabled to the disk shelves, and applying the worksheet when following the cabling procedure. ompleting the SS cabling worksheet y using the SS cabling worksheet to list the slots and SS ports for each controller, you can simplify the cabling task. bout this task You can reference the appropriate Sample SS cabling worksheet when recording your information. Procedure 1. Print out a copy of the SS cabling worksheet template to record your information. 2. Read the cabling worksheet rules and be sure to understand them. 3. Make a list of all SS ports and then all SS ports on each controller in your configuration. controller with three quad-port SS Hs is listed as 1a, 2a, 3a, 1c, 2c, 3c. controller with one quad-port SS H is listed as 1a, 1c. N3600 with one dual-port SS H is listed as 1a. N3400 is listed as 0a. N6200 series dual enclosure (with two onboard SS ports and one quad-port) is listed as 0a, 1a, 1c. 4. If you have a N3400 go to Step 5; otherwise, list the remaining ports by completing the following substeps: a. Make a list of all SS ports and then all SS ports on each controller in your configuration (in the grayed-out cells of the worksheet). controller with three quad-port SS Hs is listed as 1b, 2b, 3b, 1d, 2d, 3d. controller with one quad-port SS H is listed as 1b, 1d. N3600 with one dual-port SS H is listed as 1b. N6200 series dual enclosure (with two onboard SS ports and one quad-port) is listed as 0b, 1b, 1d. b. Rewrite the list (on the line below the grayed-out cells) so that the first 1b, 2b, 3b, 1d, 2d, 3d, 1b port in your list is moved to the end of your list: Offsetting the list by one (so that the cabling begins on the second X 10 IM System Storage N series: Universal SS and P abling Guide

19 slot/h) ensures system resiliency when cabling your storage system. controller with three quad-port SS Hs is listed as 2b, 3b, 1d, 2d, 3d, 1b. controller with one quad-port SS H is listed as 1d, 1b. N3600 with one dual-port SS H is listed as 1b. N6200 series dual enclosure (with two onboard SS ports and one quad-port) is listed as 1b, 1d, 0b. c. ross out the information in the grayed-out cells. You don't need this information anymore. You will use the offset list below the grayed-out cells to cable your system. 5. Go to abling SS ports to cable your storage system. SS cabling worksheet rules and template y understanding the rules for filling out the worksheet template, you can record your controller SS slot and port information correctly. Use the following rules when recording your information in the SS cabling worksheet. Samples of a completed worksheets are shown in the Sample cabling worksheet sections. v Ports are listed in sequence of the slot numbers to which they belong and include the slot number. For example, onboard SS ports belong to slot 0. SS port of slot 0 is written as 0a. single quad-port SS H in a physical PI slot belongs to slot 1. dditional quad-port SS Hs belong to slot 2, slot 3, and so on. SS port of slot 1 is written as 1a. SS port of slot 2 is written as 2a, and so on. v If your controller has onboard ports, they are always listed first (since they belong to slot 0) and then followed by the quad-port SS H slots (slot 1, 2, and so on). v If you have an H pair, the port list is the same for controller 1/ and controller 2/. v Only one controller slot and SS port is listed in a table cell under a stack number. v ontroller slots and SS ports are listed in sequence of the stack numbers. Note: This worksheet provides space for eight stacks. o not skip any table cells. v Only fill in controller slots and SS ports for the number of stacks you have in your configuration. For example, if you have only four stacks of disk shelves in your configuration, the columns for stack numbers 5 through 8 remain blank. SS cabling for new storage systems 11

20 v The controller SS ports and rows show two lines for controller 1/ and controller 2/. Use the first line (grayed-out) for recording the port list prior to offsetting the list by one. Use the second line for recording the list with the ports offset by one. v The worksheet has you connect square ports first, but you can cable circle ports first. However, square ports must only be connected to circle ports and circle ports must only be connected to square ports. v If your configuration has a single stack, the references to the first and last apply to the one. v If your configuration has a N3400 with a single controller, list the slot and port information on the ontroller 2/ line. Single controller N3400 systems have the controller in the bottom (2/) slot of the chassis. ontroller SS ports and ontroller ontroller 1/ ontroller 2/ ontroller 1/ ontroller SS ports and stack cabling sequence Stack number (1-8) able to disk IOM To first IOM To first IOM To last IOM and ontroller 2/ To last IOM Sample SS cabling worksheet for a N6200 series You can reference this sample SS cabling worksheet when filling in your own worksheet. The sample worksheet shows a N6200 series dual enclosure configuration (two onboard SS ports and one quad-port SS H) with two stacks of disk shelves. Note: The slots and SS ports shown in gray text for stack 3 are unused because of the limited number of stacks in this configuration. If there were three stacks, all three slots and SS ports listed would be used. Note: The two rows which are grayed-out and crossed-out are the original port lists that were made prior to offsetting the lists by one. The lines below that show the ports offset by one and would be used to cable the system. 12 IM System Storage N series: Universal SS and P abling Guide

21 ontroller SS ports and ontroller ontroller 1/ ontroller 2/ ontroller SS ports and stack cabling sequence Stack number (1-8) a 1a 1c 0a 1a 1c able to disk IOM To first IOM To first IOM and ontroller 1/ ontroller 2/ 0b 1b 0b 1b 1b 1d 1b 1d 1d 0b 1d 0b To last IOM To last IOM The following illustrates a cabled N6200 series using the information in the sample worksheet. Two examples are shown. One example shows disk shelves with the IOMs arranged side by side, similar to how a EXN3500 disk is oriented. The second example shows disk shelves with the IOMs arranged one above the other, similar to how a EXN3000 disk is oriented. Multipath H configuration ontroller 1/ ontroller 2/ 1. Slot Slot Stack 1 Stack 2 P SS P SS P SS P SS IOM IOM IOM IOM SS cabling for new storage systems 13

22 1. ontroller 1/ ontroller 2/ Slot 0 Multipath H onfiguration Slot Stack 1 6. Stack P SS P SS IOM IOM Sample SS cabling worksheet for an H pair (non N6200 series, N3150, N3220, and N3240, or N3400 ) You can reference this sample SS cabling worksheet and illustration when filling in your own worksheet. The sample worksheet shows an H pair configuration with three quad-port SS Hs and three stacks of disk shelves. Note: The slots and SS ports shown in gray text for stacks 4, 5, and 6 are unused because of the limited number of stacks in this configuration. If there were six stacks, all six slots and SS ports listed would be used. Note: The two rows which are grayed-out and crossed-out are the original port lists made prior to offsetting the lists by one. The lines below that show the ports offset by one and would be used to cable the system. 14 IM System Storage N series: Universal SS and P abling Guide

23 ontroller SS ports and and ontroller ontroller 1/ ontroller 2/ ontroller 1/ ontroller 2/ ontroller SS ports and stack cabling sequence Stack number (1-8) a 2a 3a 1c 2c 3c 1a 2a 3a 1c 2c 3c 1b 2b 3b 1d 2d 3d 2b 3b 1d 2d 3d 1b 1b 2b 3b 1d 2d 3d 2b 3b 1d 2d 3d 1b able to disk IOM To first IOM To first IOM To last IOM To last IOM The following illustrates a cabled H pair (non N6200 series, N3150, N3220, and N3240, or N3400 ) using the information in the sample worksheet. Two examples are shown. One example shows disk shelves with the IOMs arranged side by side, similar to how a EXN3500 disk is oriented. The second example shows disk shelves with the IOMs arranged one above the other, similar to how a EXN3000 disk is oriented. Mutipath H configuration ontroller 1/ ontroller 2/ 1. Slot 2 Slot 3 Slot 2 Slot Stack 1 Stack Stack 3 P SS P SS P SS P SS P SS P SS IOM IOM IOM IOM IOM IOM SS cabling for new storage systems 15

24 Multipath H configuration ontroller 1/ ontroller 2/ 1. Slot 2 Slot 3 4. Slot 2 Slot Stack 1 2. Stack Stack 3 IOM IOM P SS P SS 5. P SS 10. abling SS ports abling the SS ports involves cabling the -to- connections and the -to-controller connections from the first and last in a stack, and verifying that the SS connections are correct. efore you begin v You should have filled out the SS cabling worksheet. v Your storage system must be running the minimum software release required to support your model of SS disk shelves. The IM System Storage N series Introduction and Planning Guide on the N series support website (accessed and navigated as described in Websites) at contains support information. v If your storage system was not shipped in a system cabinet, the controllers and disk shelves must already be installed in a rack. v If your storage system will be using one or more PIe SS Hs, they must already be installed and available for cabling the disk shelves. v If you are mixing different disk models in the same stack, you should read the Storage Subsystem onfiguration Guide TR-3838 and Storage Subsystem Technical FQ on the N series support website (accessed and navigated as described in Websites). 16 IM System Storage N series: Universal SS and P abling Guide

25 bout this task The SS cable QSFP connectors are keyed; when oriented correctly into a SS port the QSFP connector clicks into place and the SS port link LE, LNK, illuminates green. o not force a connector into a port. Procedure 1. If you have more than one disk in a stack, cable the -to- SS connections by completing the following substeps; otherwise, go to Step 2: You use the QSFP to QSFP SS cables that came with your system. a. onnect IOM circle port to the next IOM square port. b. onnect IOM circle port to the next IOM square port. The following examples show a stack of three shelves connected -to-. The first example shows shelves that have the IOMs arranged side-by-side, similar to how a EXN3500 disk is oriented. The second example shows shelves that have the IOMs arranged one above the other, similar to how a EXN3000 disk is oriented. Stack of three shelves P SS P SS IOM IOM Stack of three shelves P SS IOM IOM SS cabling for new storage systems 17

26 2. Use your completed worksheet to cable the SS and SS connections for each controller. Note: If you are cabling a N3600 storage system, use the QSFP to mini-ss cables for all controller to connections; otherwise, use the QSFP to QSFP SS cables. 3. Use your completed worksheet to cable the SS and SS connections for each controller. Note: For quad-port SS Hs, ports and never connect to the same stack of disk shelves and ports and never connect to the same stack of disk shelves. This means that you might have unused H ports, depending on the number of stacks in your configuration. For example, a single-controller with one quad-port SS H and one stack of shelves only uses H ports and. 4. Verify the SS connections by entering the applicable command: v For 7-Mode, enter the following command at the system console: sasadmin expander_map For H pairs, you can run this command on either node. 5. The next step depends on the output. If... Then... The output lists all IOMs The IOMs have connectivity; go to Step 6. ny IOMs are not shown (either the output does not show an IOM because it is cabled incorrectly, or the output does not show all the IOMs downstream from the incorrectly cabled IOM.) Repeat Steps 1 through 5 to correct cabling errors, then go to Step heck whether your system has disk autoassignment enabled by using the options disk command at the console of either controller. If disk autoassignment is enabled, the output shows disk.auto_assign on. 7. If your system does not have disk autoassignment enabled, assign disk drive ownership. The following substeps are for basic disk ownership assignment for 7-Mode. To specify the disk drives to be assigned or the system to own the disk drives, see the ata ONTP Storage Management Guide for 7-Mode. For 7-Mode H pairs, you can run these commands from the system console of either node. a. Enter the following command to see all of the unassigned disk drives: disk show -n The disk drives in the hot-added have the ownership state of Not Owned. 18 IM System Storage N series: Universal SS and P abling Guide

27 b. Enter the following command to assign ownership of the disk drives: disk assign all If you need to assign the disk drives to a non-local storage system, you can specify a storage system by using the -o owner_name option. To determine the owner_name, you can run the hostname command at the console of either controller. c. Enter the following command to verify the assignments that you made: disk show -v 8. The next step depends on whether you are using the P capability. If you are... Using the P capability Not using the P capability Then... Go to abling P connections. oot the storage system and begin setup. ttention: fter your system is up and serving data, you cannot move SS cables nondisruptively. SS cabling examples You can use the SS cabling examples to see how the SS cabling rules are applied for common configurations. Examples of SS cabling for H pairs with quad-port Hs You can reference these examples for multipath H configurations with quad-port SS Hs. The numbered cables show the sequence in which the system should be cabled. Two examples are shown for each configuration type. One example shows disk shelves with the IOMs arranged side by side, similar to how a EXN3500 disk is oriented. The second example shows disk shelves with the IOMs arranged one above the other, similar to how a EXN3000 disk is oriented. Note: These examples do not apply to N3400, N3150, N3220 and N3240, or N6200 series systems. SS cabling for new storage systems 19

28 One quad-port SS H and a single stack The SS port cabling sequence for each controller is 1a, 1d. Multipath H configuration ontroller 1/ ontroller 2/ Stack 1 3. P SS P SS IOM IOM Multipath H configuration 1. ontroller 1/ ontroller 2/ P SS 3. IOM IOM 20 IM System Storage N series: Universal SS and P abling Guide

29 One quad-port SS H and two single stacks The SS port cabling sequence for each controller is 1a, 1c, 1d, 1b. Multipath H configruation ontroller 1/ ontroller 1/ P SS P SS P SS P SS IOM IOM IOM IOM Multipath H configruation ontroller 1/ ontroller 1/ P SS P SS IOM IOM SS cabling for new storage systems 21

30 Two quad-port SS Hs and two stacks of disk shelves The SS port cabling sequence for each controller is 1a, 2a, 2b, 1d. Multipath H configuration ontroller 1/ ontroller 2/ Slot Slot Stack 1 Stack 2 P SS P SS P SS P SS 5. IOM IOM IOM IOM IM System Storage N series: Universal SS and P abling Guide

31 Multipath H onfiguration ontroller 1/ ontroller 2/ Slot 2 2. Slot Stack 1 Stack 2 5. P SS P SS 6. IOM IOM 8. Three quad-port SS Hs and three stacks of disk shelves The SS port cabling sequence for each controller is 1a, 2a, 3a, 2b, 3b, 1d. Mutipath H configuration ontroller 1/ ontroller 2/ 1. Slot 2 Slot 3 Slot 2 Slot Stack 1 Stack Stack 3 P SS P SS P SS P SS P SS P SS IOM IOM IOM IOM IOM IOM SS cabling for new storage systems 23

32 Multipath H configuration ontroller 1/ ontroller 2/ 1. Slot 2 Slot 3 4. Slot 2 Slot Stack 1 2. Stack Stack 3 IOM IOM P SS P SS 5. P SS 10. Four quad-port SS Hs and four stacks of disk shelves The SS port cabling sequence for each controller is 1a, 2a, 3a, 4a, 2b, 3b, 4b, 1d. Four quad-port SS Hs and eight stacks of disk shelves The SS port cabling sequence for each controller is 1a, 2a, 3a, 4a, 1c, 2c, 3c, 4c, 2b, 3b, 4b, 1d, 2d, 3d, 4d, 1b. Five quad-port SS Hs and five stacks of disk shelves The SS port cabling sequence for each controller is 1a, 2a, 3a, 4a, 5a, 2b, 3b, 4b, 5b, 1d, 2d, 3d, 4d, 1b. Five quad-port SS Hs and 10 stacks of disk shelves The SS port cabling sequence for each controller is 1a, 2a, 3a, 4a, 5a, 1c, 2c, 3c, 4c, 5c, 2b, 3b, 4b, 5b,1d, 2d, 3d, 4d, 5d,1b. 24 IM System Storage N series: Universal SS and P abling Guide

33 Examples of SS cabling for single-controller configurations with quad-port Hs You can reference these SS cabling examples for single-controller configurations with quad-port SS Hs (dual-path configurations). The numbered cables show the sequence in which the system should be cabled. Two examples are shown for each configuration type. One example shows disk shelves with the IOMs arranged side by side, similar to how a EXN3500 disk is oriented. The second example shows disk shelves with the IOMs arranged one above the other, similar to how a EXN3000 disk is oriented. Note: These examples do not apply to N3400, N3220 and N3240, or N6200 series systems. One quad-port SS H and one stack of disk shelves The SS port cabling sequence is 1a, 1d. ual-path configuration ontroller 1/ 1. Stack 1 2. P SS P SS IOM IOM SS cabling for new storage systems 25

34 ual-path configuration 1. IOM IOM ontroller 1/ Stack 1 P SS 2. One quad-port SS H and two stacks of disk shelves The SS port cabling sequence is 1a, 1c,1d, 1b. ual-path configurations ontroller 1/ Stack 1 Stack 2 P SS P SS P SS P SS IOM IOM IOM IOM 26 IM System Storage N series: Universal SS and P abling Guide

35 ual-path configuration 1. ontroller 1/ Stack 1 Stack 2 P SS P SS IOM IOM Two quad-port SS Hs and two stacks of disk shelves The SS port cabling sequence is 1a, 2a, 2b, 1d. 4. ual-path configurations 1. ontroller 1/ Slot Stack 1 Stack 2 P SS P SS P SS P SS IOM IOM IOM IOM SS cabling for new storage systems 27

36 ual-path configuration ontroller 1/ Slot Stack 1 Stack 2 P SS P SS IOM IOM Examples of SS cabling for N6200 series systems You can reference these SS cabling examples for N6200 series dual enclosure H and single enclosure H configurations. The numbered cables show the sequence in which the system should be cabled. Two examples are shown for each configuration type. One example shows disk shelves with the IOMs arranged side by side, similar to how a EXN3500 disk is oriented. The second example shows disk shelves with the IOMs arranged one above the other, similar to how a EXN3000 disk is oriented. Note: You can also view the FSN6200 series Series System abling Examples document a more real-world cabling example of a N6200 series system installed in a cabinet on the N series support website (accessed and navigated as described in Websites) at nseries. 28 IM System Storage N series: Universal SS and P abling Guide

37 N6200 series dual enclosure H configuration The SS port cabling sequence for each controller is 0a,1a, 1b,1d. Multipath H configuration ontroller 1/ ontroller 2/ 1. Slot Slot Stack 1 Stack 2 P SS P SS P SS P SS IOM IOM IOM IOM ` 1. ontroller 1/ ontroller 2/ Slot 0 Multipath H onfiguration Slot Stack 1 6. Stack P SS P SS IOM IOM SS cabling for new storage systems 29

38 N6200 series single enclosure H configuration The SS port cabling sequence for each controller is 0a, 0b. Multipath H configuration Slot 0 Slot 0 Stack 1 P SS P SS ontroller 1/ ontroller 2/ IOM IOM Multipath H configuration Slot 0 1. ontroller 1/ 3. Slot 0 2. ontroller 2/ 4. Stack 1 P SS IOM IOM 30 IM System Storage N series: Universal SS and P abling Guide

39 Examples of SS cabling for N3150, N3220, and N3240 system models You can reference these SS cabling examples for N3200 series H pair and single-controller configurations. The numbered cables show the sequence in which the system should be cabled. For configurations with external disk shelves, two examples are shown for each configuration type. One example shows disk shelves with the IOMs arranged side by side, similar to how a EXN3500 disk is oriented. The second example shows disk shelves with the IOMs arranged one above the other, similar to how a EXN3000 disk is oriented. Note: These examples show a N3150 or a N3220, but the cabling also applies to the N3240, even though the controllers are in a different position in the N3240. N3150, N3220, and N3240H pair configuration with one stack of disk shelves (multipath H) The SS port cabling sequence for each controller is 0a, 0b. SS SS 0b 0a 0b 0a P SS P SS IOM IOM 4. P SS P SS P SS P SS SS cabling for new storage systems 31

40 SS SS 0b 0a 0b 0a P SS 3. IOM IOM 4. N3150, N3220, and N3240 single-controller configuration with one stack of disk shelves (dual-path) The SS port cabling sequence is 0a, 0b. Note: ual-path provides greater resiliency, but when dual-path is used ata ONTP 8.1.x issues occasional warnings to the console because mixed paths are detected. To avoid the warnings, single-path connections to the external SS storage are a supported option in these configurations. SS P 0b 0a P SS P SS IOM IOM P SS P SS P SS P SS 32 IM System Storage N series: Universal SS and P abling Guide

41 SS 0b 0a 1. P SS 2. IOM IOM N3150, N3220, and N3240 single-controller configuration with one stack of disk shelves (single-path) The SS port cabling sequence is 0a. SS P 0b 0a P SS P SS IOM IOM P SS P SS P SS P SS SS cabling for new storage systems 33

42 SS 0b 0a P SS IOM IOM N3150 and N3220 H pair configuration with no external disk shelves (multipath H) The SS port cabling sequence for each controller is 0a, 0b. SS SS 0b 0a 0b 0a Examples of SS cabling for N3600 systems You can reference these SS cabling examples for N3600 H pair (multipath H) and single-controller (dual-path) configurations. The numbered cables show the sequence in which the system should be cabled. Two examples are shown for each configuration type. One example shows disk shelves with the IOMs arranged side by side, similar to how a EXN3500 disk is oriented. The second example shows disk shelves with the IOMs arranged one above the other, similar to how a EXN3000 disk is oriented. Note: For single-controller N3400 storage systems, the controller is in Slot (the bottom slot); therefore, the controller is cabled as if it were controller 2/. If a second controller is added to make this an H pair configuration, the new controller is cabled as controller 1/. 34 IM System Storage N series: Universal SS and P abling Guide

43 Note: ecause N3600 systems only have one dual-port SS H on each controller, a maximum of one stack of disk shelves is supported in a multipath H or dual-path configuration. N3600 multipath H configuration The SS port cabling sequence for each controller is 1a,1b. ontroller 1/ H pair configuration ontroller 2/ Stack P SS P SS IOM IOM SS cabling for new storage systems 35

44 ontroller 1/ H pair configuration ontroller 2/ Stack 1 P SS 3. IOM IOM 4. N3600 multipath H configuration with one disk The SS port cabling sequence for each controller is 1a,1b. 1. H pair configuration ontroller 1/ ontroller 2/ 4. Stack P SS P SS IOM IOM 36 IM System Storage N series: Universal SS and P abling Guide

45 1. H pair configuration ontroller 1/ ontroller 2/ 3. IOM P SS IOM N3600 dual-path configuration The SS port cabling sequence is 1a, 1b. Single-controller configuration ontroller 2/ Stack 1 P SS P SS IOM IOM SS cabling for new storage systems 37

46 Single-controller configuration 1. ontroller 2/ 2. IOM IOM Stack 1 P SS N3600 dual-path configuration with one disk The SS port cabling sequence is 1a,1b. Single-controller configuration ontroller 2/ Stack 1 P SS P SS IOM IOM 38 IM System Storage N series: Universal SS and P abling Guide

47 Single-controller configuration ontroller 2/ P SS IOM IOM Examples of SS cabling for N3400 systems You can reference these SS cabling examples for N3400 H pair (single-path H) and single-controller (single-path) configurations. The numbered cables show the sequence in which the system should be cabled. Two examples are shown for each configuration type. One example shows disk shelves with the IOMs arranged side by side, similar to how a EXN3500 disk is oriented. The second example shows disk shelves with the IOMs arranged one above the other, similar to how a EXN3000 disk is oriented. Note: For single-controller N3400 storage systems, the controller is in Slot (the bottom slot); therefore, the controller is cabled as if it were controller 2/. If a second controller is added to make this an H pair configuration, the new controller is cabled as controller 1/. Note: The N3400 storage system s onboard SS port labeled 0d is treated as slot 0 port a (0a) for cabling purposes. When the onboard port is treated as port 0a, all the SS cabling rules can be applied. Note: ecause N3400 systems only have one SS port on each controller, a maximum of one stack of disk shelves is supported. SS cabling for new storage systems 39

48 N3400 single-path H configuration The SS port cabling sequence for each controller is 0a. 1. ontroller 1/ 0a 0d H pair configuration e0p 0a 0d ontroller 2/ e0p Stack 1 2. P SS P SS IOM IOM 1. ontroller 1/ 0a 0d H pair configuration e0p 0a 0d ontroller 2/ e0p 2. P Stack 1 SS IOM IOM 40 IM System Storage N series: Universal SS and P abling Guide

49 N3400 single-path configuration The SS port cabling sequence is 0a. Single-controller configuration ontroller 2/ 0a 0d e0p 1. Stack 1 P SS P SS IOM IOM Single-controller configuration ontroller 2/ 0a 0d 1. e0p Stack 1 P SS IOM IOM SS cabling for new storage systems 41

50 42 IM System Storage N series: Universal SS and P abling Guide

51 P cabling for new storage systems fter you cable the SS connections, you have the option to cable the P connections. It is recommended that you use the P protocol because it enables ata ONTP to manage and control the SS disk storage subsystem. P cabling rules You can cable P connections on your storage system by applying the P cabling rules. General P cabling rules General P cabling rules apply to all supported storage systems using SS storage. v You must use T6 Ethernet cables with RJ-45 connectors for P connections. v If your storage system does not have a dedicated onboard network interface for each controller, you must dedicate one for each controller at system setup. You can use a quad-port Ethernet card. v ll P connections to the disk are cabled through the P ports, which are designated by a square symbol or a circle symbol. P connectivity rules P connectivity rules apply to all supported storage systems using SS storage. Shelf-to- connections v ll the disk shelves in a stack are daisy-chained when you have more than one in a stack. v IOM circle port is connected to the next IOM square port. IOM circle port is connected to the next IOM square port. Intrastack connections v The last and first in each stack are connected to provide resiliency within each stack of disk shelves. v The last IOM circle port is connected to the first IOM square port. This applies to stacks containing one or more disk shelves. opyright IM orp

52 ontroller-to-stack connections v Each storage system controller is connected to each stack of disk shelves through a dedicated. v ontroller 1/ always connects to the first IOM square port in a stack. ontroller 2/ always connects to the last IOM circle port in a stack. ontroller-to-controller connections (N3150, N3220, and N3240 system models with no external SS shelves) Each storage system controller is connected to the partner controller through a dedicated wrench icon. This rule applies to N3150, N3220, and N3240 storage systems only. N3400 storage system connections For single-controller N3400 storage systems, the controller is in Slot (the bottom slot); therefore, the controller is cabled as if it were controller 2/. If a second controller is added to make this an H pair, the new controller is cabled as controller 1/. abling P connections How you cable your system for P depends on whether you are cabling a storage system with external SS storage or a system with no external SS storage. abling P on systems with external SS storage abling P on a system with external SS disk shelves involves connecting disk shelves within a stack, connecting the first and last disk shelves in a stack, connecting the stacks (if you have more than one stack), and connecting the controllers to the stacks. efore you begin If your storage system does not have a native onboard P port, you must be prepared to designate a network interface for each controller at system setup. If you are using a four-port Ethernet card for this purpose, this card must already be installed and available in each controller. Two examples are shown for each configuration type. One example shows disk shelves with the IOMs arranged side by side, similar to how a EXN3500 disk is oriented. The second example shows disk shelves with the IOMs 44 IM System Storage N series: Universal SS and P abling Guide

53 arranged one above the other, similar to how a EXN3000 disk is oriented. bout this task To cable the P connections, you use the Ethernet cables that came with your system. Procedure 1. If you have more than one disk in a stack, cable your -to- P connections; otherwise, go to Step 2. a. onnect each IOM circle port to the next IOM square port until all shelves in each stack are connected. b. onnect each IOM circle port to the next IOM square port until all shelves in each stack are connected. aisy-chain connections P SS P SS IOM IOM aisy-chain connections P SS IOM IOM 2. able the intrastack connection. P cabling for new storage systems 45

54 If you have... More than one disk in a stack of disk shelves Then... onnect the last IOM circle port to the first IOM square port and repeat for all stacks. Intrastack connection P SS P SS IOM IOM Intrastack connection P SS IOM IOM Only one disk in a stack of disk shelves onnect the IOMs within the disk by connecting the IOM circle port to the IOM square of the disk. Intrastack connection P SS P SS IOM IOM P SS IOM IOM 46 IM System Storage N series: Universal SS and P abling Guide

55 3. If you have more than one stack of disk shelves, cable the stack-to-stack connections; otherwise, go to Step 4. a. eginning with Stack 1, connect the last IOM circle port to the next stack's first IOM square port. Stack 1 P SS P SS IOM IOM Stack-to-stack connections Stack 2 P SS P SS IOM IOM Stack 3 P SS P SS IOM IOM Stack 1 Stack-to-stack connections Stack 2 Stack 3 P SS P SS P SS IOM IOM b. Repeat Substep a until all stacks are connected. 4. able controller-to-stack connections. If your system has a controller... Then... 1/ able controller 1/ to the first stack first IOM square port. 2/ able controller 2/ to the last stack last IOM circle port. n H pair with two stacks of disk shelves has the controller-to-stack connections cabled as follows: P cabling for new storage systems 47

56 Note: N3400 storage systems use the e0p port on each controller. ontroller 1/ ontroller 2/ Stack 1 Stack 2 P SS P SS P SS P SS IOM IOM IOM IOM ontroller 1/ ontroller 2/ IOM IOM P Stack 1 SS Stack 2 P SS 5. Verify that the P cabling is correct by entering the applicable command: v For 7-Mode, enter the following command from the system console:storage show acp If you have an H pair, run this command on both nodes. 6. The next step depends on what the command output is for each node. If the result in the output shows P connectivity status... Full onnectivity Then... P cabling is correct. The number of IOMs detected out-of-band (through P) and in-band (through SS) are the same. 48 IM System Storage N series: Universal SS and P abling Guide

57 If the result in the output shows P connectivity status... Then... No onnectivity Repeat Step 4. Partial onnectivity dditional onnectivity No P ports on the IOMs are connected to the storage controllers. Repeat Steps 1 through 6 to see what P connections were missed. Fewer IOMs are detected out-of-band (through P) than in-band (through SS). Repeat the abling SS ports procedure to see what SS connections were missed. More IOMs are detected out-of-band (through P) than in-band (through SS). 7. oot the storage system and begin setup. See the Installation and Setup Instructions that came with your storage system. Note: If your storage system does not have a dedicated P onboard on each controller for P, you will designate them at setup. ttention: fter your storage system is up and serving data, you cannot move SS cables nondisruptively. abling P on systems with no external SS storage abling your N3150, N3220, and N3240 H pair with internal SS storage for P involves one connection between the two controller modules. Procedure able the locked wrench P port on one controller module to the same port on the partner controller module. The following example shows a N3150 or a N3220, but the cabling also applies to the N3240, even though the controllers are in a different position in the N3240. SS P (Locked wrench) SS P (Locked wrench) 0b 0a 0b 0a P cabling for new storage systems 49

Universal SAS and ACP Cabling Guide

Universal SAS and ACP Cabling Guide IM System Storage N series Universal SS and P abling Guide G27-3919-04 ontents Preface................................ v Supported features............................. v Websites................................

More information

EXN3000 Storage Expansion Unit Installation and Setup Instructions

EXN3000 Storage Expansion Unit Installation and Setup Instructions IBM System Storage EXN3000 Storage Expansion Unit Installation and Setup Instructions G52-1345-03 Notices Mail comments to: IBM orporation Attention epartment GZW 9000 South Rita Road Tucson, AZ 85744-0001

More information

Installation and Cabling Guide

Installation and Cabling Guide SAS Disk Shelves Installation and Cabling Guide For DS460C, DS224C, and DS212C August 2017 215-11123_C0 doccomments@netapp.com Table of Contents 3 Contents Installing and cabling disk shelves with IOM12

More information

Fibre Channel and iscsi Configuration Guide for the Data ONTAP 8.0 Release Family

Fibre Channel and iscsi Configuration Guide for the Data ONTAP 8.0 Release Family IBM System Storage N series Fibre Channel and iscsi Configuration Guide for the Data ONTAP 8.0 Release Family GA32-0783-03 Table of Contents 3 Contents Preface... 7 Supported features... 7 Websites...

More information

N3240 Installation and Setup Instructions

N3240 Installation and Setup Instructions IBM System Storage N3240 Installation and Setup Instructions Covering the N3240 model GA32-2203-01 Notices Mail comments to: IBM Corporation Attention Department GZW 9000 South Rita Road Tucson, AZ 85744-0001

More information

N3220 Installation and Setup Instructions

N3220 Installation and Setup Instructions IBM System Storage N3220 Installation and Setup Instructions Covering the N3220 model GA32-2202-01 Notices Mail comments to: IBM Corporation Attention Department GZW 9000 South Rita Road Tucson, AZ 85744-0001

More information

Data ONTAP 8.1 High Availability and MetroCluster Configuration Guide For 7-Mode

Data ONTAP 8.1 High Availability and MetroCluster Configuration Guide For 7-Mode IBM System Storage N series Data ONTAP 8.1 High Availability and MetroCluster Configuration Guide For 7-Mode This Release Candidate publication is provided in conjunction with a Data ONTAP 8.1.2 RC code

More information

N3150 Installation and Setup Instructions

N3150 Installation and Setup Instructions IBM System Storage N350 Installation and Setup Instructions Covering the N350 model GC27-426-0 Notices Mail comments to: IBM Corporation Attention Department GZW 9000 South Rita Road Tucson, AZ 85744-000

More information

FibreBridge 7500N and 6500N Configuring a MetroCluster system with SAS disk shelves and FibreBridge bridges in 7-mode

FibreBridge 7500N and 6500N Configuring a MetroCluster system with SAS disk shelves and FibreBridge bridges in 7-mode FibreBridge 7500N and 6500N Configuring a MetroCluster system with SAS disk shelves and FibreBridge bridges in 7-mode November 2017 215-05845_H0 doccomments@netapp.com Table of Contents 3 Contents Configuring

More information

Clustered Data ONTAP 8.2 High-Availability Configuration Guide

Clustered Data ONTAP 8.2 High-Availability Configuration Guide IBM System Storage N series Clustered Data ONTAP 8.2 High-Availability Configuration Guide SC27-6276-02 Table of Contents 3 Contents Preface... 7 About this guide... 7 Supported features... 7 Websites...

More information

N6000 Series Filer Installation and Setup Instructions

N6000 Series Filer Installation and Setup Instructions IBM System Storage N6000 Series Filer Installation and Setup Instructions Covering N6040, N6060, and N6070 models GC53-1143-04 Notices Mail comments to: IBM Corporation Attention Department GZW 9000 South

More information

Clustered Data ONTAP 8.2

Clustered Data ONTAP 8.2 Clustered Data ONTAP 8.2 NAS Express Setup Guide for 62xx Systems NetApp, Inc. 495 East Java Drive Sunnyvale, CA 94089 U.S. Telephone: +1 (408) 822-6000 Fax: +1 (408) 822-4501 Support telephone: +1 (888)

More information

Clustered Data ONTAP 8.2

Clustered Data ONTAP 8.2 Clustered Data ONTAP 8.2 SAN Express Setup Guide for 62xx Systems NetApp, Inc. 495 East Java Drive Sunnyvale, CA 94089 U.S. Telephone: +1(408) 822-6000 Fax: +1(408) 822-4501 Support telephone: +1 (888)

More information

Data ONTAP 8.1 Software Setup Guide for 7-Mode

Data ONTAP 8.1 Software Setup Guide for 7-Mode IBM System Storage N series Data ONTAP 8.1 Software Setup Guide for 7-Mode GA32-1044-03 Contents Preface................................ 1 About this guide.............................. 1 Supported features.............................

More information

SAS Disk Shelves. Service Guide. For DS460C, DS224C and DS212C. November _C0

SAS Disk Shelves. Service Guide. For DS460C, DS224C and DS212C. November _C0 SAS Disk Shelves Service Guide For DS460C, DS224C and DS212C November 2018 215-11810_C0 doccomments@netapp.com Table of Contents 3 Contents Hot-swapping a disk drive in a DS224C or DS212C disk shelf...

More information

Before you begin. Unpack & Prepare. Install Hardware. Connect Drive Shelves. Apply Power. Connect Data Hosts. Connect Ethernet Cables

Before you begin. Unpack & Prepare. Install Hardware. Connect Drive Shelves. Apply Power. Connect Data Hosts. Connect Ethernet Cables efore you begin Installation and Setup Instructions for E-Series E5760 and E860 Shelves E5760 and E860 controller shelves DE60C drive shelf Unpack & Prepare Install Hardware Connect Drive Shelves pply

More information

Windows Host Utilities Installation and Setup Guide

Windows Host Utilities Installation and Setup Guide IBM System Storage N series Windows Host Utilities 6.0.1 Installation and Setup Guide GC52-1295-06 Table of Contents 3 Contents Preface... 7 Supported features... 7 Websites... 7 Getting information,

More information

Data ONTAP 8.2 Software Setup Guide For 7-Mode

Data ONTAP 8.2 Software Setup Guide For 7-Mode IBM System Storage N series Data ONTAP 8.2 Software Setup Guide For 7-Mode SC27-5926-02 Table of Contents 3 Contents Preface... 7 About this guide... 7 Supported features... 7 Websites... 8 Getting information,

More information

EXN4000 Storage Expansion Unit Installation and Setup Instructions

EXN4000 Storage Expansion Unit Installation and Setup Instructions IBM System Storage EXN4000 Storage Expansion Unit Installation and Setup Instructions GC27-2079-02 IBM System Storage EXN4000 Storage Expansion Unit Installation and Setup Instructions GC27-2079-02 Notices

More information

Data ONTAP 8.1 Upgrade and Revert/Downgrade Guide for 7-Mode

Data ONTAP 8.1 Upgrade and Revert/Downgrade Guide for 7-Mode IBM System Storage N series Data ONTAP 8.1 Upgrade and Revert/Downgrade Guide for 7-Mode GA32-1034-03 Contents Preface................................ 1 About this guide..............................

More information

Data ONTAP 8.2 Upgrade and Revert/Downgrade Guide For 7-Mode

Data ONTAP 8.2 Upgrade and Revert/Downgrade Guide For 7-Mode IBM System Storage N series Data ONTAP 8.2 Upgrade and Revert/Downgrade Guide For 7-Mode SC27-5925-03 Contents Preface................................ vii About this guide.............................

More information

Data ONTAP Mode Software Setup Guide

Data ONTAP Mode Software Setup Guide IBM System Storage N series Data ONTAP 8.0 7-Mode Software Setup Guide GA32-0735-03 Table of Contents 3 Contents Supported features... 7 Websites... 9 Getting information, help, and service... 11 Before

More information

FlexArray Virtualization

FlexArray Virtualization Updated for 8.3.2 FlexArray Virtualization Installation Requirements and Reference Guide NetApp, Inc. 495 East Java Drive Sunnyvale, CA 94089 U.S. Telephone: +1 (408) 822-6000 Fax: +1 (408) 822-4501 Support

More information

Dell EMC ME4 Series JBOD 5U84 Enclosure

Dell EMC ME4 Series JBOD 5U84 Enclosure Dell EMC ME4 Series JBOD 5U84 Enclosure Deployment Guide Regulatory Model: E09J, E10J, E11J Regulatory Type: E09J001, E10J001, E11J001 Notes, cautions, and warnings NOTE: A NOTE indicates important information

More information

Hardware and Service Guide

Hardware and Service Guide IBM System Storage EXN3000 Storage Expansion Unit Hardware and Serice Guide GC52-1346-10 Note: Before using this information and the product it supports, be sure to read the general information in Notices

More information

Data ONTAP 8.2 Storage Management Guide For 7-Mode

Data ONTAP 8.2 Storage Management Guide For 7-Mode IBM System Storage N series Data ONTAP 8.2 Storage Management Guide For 7-Mode SC27-5928-02 Table of Contents 3 Contents Preface... 17 About this guide... 17 Supported features... 17 Websites... 18 Getting

More information

N3150, N3220, and N3240 Hardware and Service Guide

N3150, N3220, and N3240 Hardware and Service Guide IBM System Storage N3150, N3220, and N3240 Hardware and Service Guide CoveringtheN3150,N3220,andN3240models SC27-4214-04 Note: Before using this information and the product it supports, be sure to read

More information

High Availability and MetroCluster Configuration Guide For 7-Mode

High Availability and MetroCluster Configuration Guide For 7-Mode Updated for 8.2.1 Data ONTAP 8.2 High Availability and MetroCluster Configuration Guide For 7-Mode NetApp, Inc. 495 East Java Drive Sunnyvale, CA 94089 U.S. Telephone: +1 (408) 822-6000 Fax: +1 (408) 822-4501

More information

E-Series Cabling E-Series Hardware

E-Series Cabling E-Series Hardware E-Series Cabling E-Series Hardware September 2018 215-13049_A0 doccomments@netapp.com Table of Contents 3 Contents Overview and requirements... 4 Cabling your storage system... 5 Host cabling... 5 Cabling

More information

AIX Host Utilities 6.0 Installation and Setup Guide

AIX Host Utilities 6.0 Installation and Setup Guide IBM System Storage N series AIX Host Utilities 6.0 Installation and Setup Guide GC27-3925-01 Table of Contents 3 Contents Preface... 6 Supported features... 6 Websites... 6 Getting information, help,

More information

Data ONTAP 8.1 SAN Administration Guide For 7-Mode

Data ONTAP 8.1 SAN Administration Guide For 7-Mode IBM System Storage N series Data ONTAP 8.1 SAN Administration Guide For 7-Mode GA32-1035-02 Table of Contents 3 Contents Preface... 8 About this guide... 8 Supported features... 8 Websites... 8 Getting

More information

HPE Direct-Connect External SAS Storage for HPE BladeSystem Solutions Deployment Guide

HPE Direct-Connect External SAS Storage for HPE BladeSystem Solutions Deployment Guide HPE Direct-Connect External SAS Storage for HPE BladeSystem Solutions Deployment Guide This document provides device overview information, installation best practices and procedural overview, and illustrated

More information

Introduction to NetApp E-Series E2700 with SANtricity 11.10

Introduction to NetApp E-Series E2700 with SANtricity 11.10 d Technical Report Introduction to NetApp E-Series E2700 with SANtricity 11.10 Todd Edwards, NetApp March 2014 TR-4275 1 Introduction to NetApp E-Series E2700 with SANtricity 11.10 TABLE OF CONTENTS 1

More information

HPE BladeSystem c3000 Enclosure Quick Setup Instructions

HPE BladeSystem c3000 Enclosure Quick Setup Instructions HPE BladeSystem c3000 Enclosure Quick Setup Instructions Part Number: 446990-007 2 Site requirements Select an installation site that meets the detailed installation site requirements described in the

More information

Installation and Configuration Guide

Installation and Configuration Guide Installation and Configuration Guide Trademark Notices Comtrol, NS-Link, and DeviceMaster are trademarks of Comtrol Corporation. Microsoft and Windows are registered trademarks of Microsoft Corporation.

More information

HPE Synergy Configuration and Compatibility Guide

HPE Synergy Configuration and Compatibility Guide HPE Synergy Configuration and Compatibility Guide Abstract This guide describes HPE Synergy hardware configuration options and compatibility. Hewlett Packard Enterprise assumes you are qualified in the

More information

System Storage DS3950 Quick Start Guide

System Storage DS3950 Quick Start Guide System Storage DS3950 Quick Start Guide This Quick Start Guide describes the basic procedure for installing, cabling, and configuring the IBM System Storage DS3950 storage subsystem (Machine Types 1814-94H

More information

ETERNUS JX60. Technical Product Introduction. 0 Copyright Fujitsu, Release June 2014

ETERNUS JX60. Technical Product Introduction. 0 Copyright Fujitsu, Release June 2014 0 Copyright Fujitsu, Release June 2014 Highlights The passive storage subsystem accommodates up to 240 HDDs 3.5" SAS 2.0 Nearline SAS 7200 rpm, max. storage capacity 960 TB 1) One or two 6 Gbit/s SAS interfaces

More information

E-Series Hardware Cabling Guide

E-Series Hardware Cabling Guide E-Series Hardware Cabling Guide June 2017 215-11208_C0 doccomments@netapp.com Table of Contents 3 Contents Deciding whether to use this guide... 6 Cabling concepts and best practices... 7 Cabling concepts...

More information

ULTRATRAK SERIES RM4000, SX4000, RM8000, SX8000, RM15000 USER MANUAL. Version 2.2

ULTRATRAK SERIES RM4000, SX4000, RM8000, SX8000, RM15000 USER MANUAL. Version 2.2 ULTRATRAK SERIES RM4000, SX4000, RM8000, SX8000, RM15000 USER MANUAL Version 2.2 UltraTrak Series User Manual Copyright 2003, Promise Technology, Inc. All Rights Reserved. Copyright by Promise Technology,

More information

MetroCluster Service and Expansion Guide

MetroCluster Service and Expansion Guide ONTAP 9 MetroCluster Service and Expansion Guide March 2018 215-09065_K0 doccomments@netapp.com Updated for ONTAP 9.3 Table of Contents 3 Contents Deciding whether to use this guide... 6 Where to find

More information

OnCommand Unified Manager Installation and Setup Guide for Use with Core Package 5.2 and Host Package 1.3

OnCommand Unified Manager Installation and Setup Guide for Use with Core Package 5.2 and Host Package 1.3 IBM System Storage N series OnCommand Unified Manager Installation and Setup Guide for Use with Core Package 5.2 and Host Package 1.3 GA32-1020-03 Table of Contents 3 Contents Preface... 10 Supported

More information

VTRAK E-Class/J-Class Quick Start Guide

VTRAK E-Class/J-Class Quick Start Guide VTRAK E-Class/J-Class Quick Start Guide Version.0 Firmware 3.9 008 Promise Technology, Inc. All Rights Reserved. VTrak Quick Start Guide About This Guide This Quick Start Guide shows you how to install

More information

Chapter. Getting Started. In this Chapter...

Chapter. Getting Started. In this Chapter... Getting Started hapter In this hapter... Introduction...-2 onventions Used...- What s in the ox?...- Getting Started...- efore You egin......- Step - Install onfiguration Software...- Step 2 - Launch onfiguration

More information

CHAPTER CONFIGURING THE ERM AND SLAVE MODULES WITH ERM WORKBENCH. In This Chapter:

CHAPTER CONFIGURING THE ERM AND SLAVE MODULES WITH ERM WORKBENCH. In This Chapter: ONFIGURING THE ERM N SLVE MOULES WITH ERM WORKENH HPTER In This hapter: ERM Workbench Software............................................ Launching ERM Workbench...........................................

More information

Cisco UCS S3260 System Storage Management

Cisco UCS S3260 System Storage Management Storage Server Features and Components Overview, page 1 Cisco UCS S3260 Storage Management Operations, page 9 Disk Sharing for High Availability, page 10 Storage Enclosure Operations, page 17 Sas Expander

More information

E-Series Hardware Cabling Guide

E-Series Hardware Cabling Guide E-Series Hardware Cabling Guide April 2018 215-11792_C0 doccomments@netapp.com Table of Contents 3 Contents Deciding whether to use this guide... 6 Cabling concepts and best practices... 7 Cabling concepts...

More information

IBM Netfinity High Availability Cluster Solutions. Installation and User's Guide

IBM Netfinity High Availability Cluster Solutions. Installation and User's Guide IBM Netfinity High vailability Cluster Solutions Installation and User's Guide IBM Netfinity High vailability Cluster Solutions Installation and User's Guide IBM Note Before using this information and

More information

SnapManager 8.0 for Microsoft SharePoint Installation Guide

SnapManager 8.0 for Microsoft SharePoint Installation Guide IBM System Storage N series SnapManager 8.0 for Microsoft SharePoint Installation Guide GC27-2097-07 Contents Preface... 4 Supported Features... 4 Websites... 4 Getting Information, Help, and Service...

More information

SAS Connectivity Card (CIOv) for IBM BladeCenter IBM Redbooks Product Guide

SAS Connectivity Card (CIOv) for IBM BladeCenter IBM Redbooks Product Guide SAS Connectivity Card (CIOv) for IBM BladeCenter IBM Redbooks Product Guide The SAS Connectivity Card (CIOv) for IBM BladeCenter is an expansion card that offers the ideal way to connect the supported

More information

PASS4TEST. IT Certification Guaranteed, The Easy Way! We offer free update service for one year

PASS4TEST. IT Certification Guaranteed, The Easy Way!   We offer free update service for one year PASS4TEST IT Certification Guaranteed, The Easy Way! \ http://www.pass4test.com We offer free update service for one year Exam : HP2-T15 Title : Servicing HP BladeSystem Vendors : HP Version : DEMO Get

More information

HP 3PAR OS Messages and Operators Guide

HP 3PAR OS Messages and Operators Guide HP 3PAR OS 3.1.1 Messages and Operators Guide Abstract This guide is for system administrators and experienced users who are familiar with the storage systems, understand the operating system(s) they are

More information

Voter Remote Interface (VRI) for the Raytheon JPS Communications SNV Channel DSP Voter

Voter Remote Interface (VRI) for the Raytheon JPS Communications SNV Channel DSP Voter Voter Remote Interface (VRI) for the Raytheon JPS Communications SNV-12 12 Channel DSP Voter Instruction Manual Issue 1 Rev 7, March 2012 Part Number FI-20080219 Fial Incorporated 710 Center Street Oregon

More information

Hardware Owner s Manual

Hardware Owner s Manual Dell PowerVault MD3000 RAID Enclosure Hardware Owner s Manual www.dell.com support.dell.com Notes, Notices, and Cautions NOTE: A NOTE indicates important information that helps you make better use of your

More information

Dell PowerEdge FD332. Owner's Manual. Regulatory Model: E02B Regulatory Type: E02B003

Dell PowerEdge FD332. Owner's Manual. Regulatory Model: E02B Regulatory Type: E02B003 Dell PowerEdge FD332 Owner's Manual Regulatory Model: E02B Regulatory Type: E02B003 Notes, cautions, and warnings NOTE: A NOTE indicates important information that helps you make better use of your computer.

More information

SYSTIMAX imvision Controller User Guide

SYSTIMAX imvision Controller User Guide Issue 3 SYSTIMAX imvision Controller User Guide Table of Contents Overview... 2 Important Safety Instructions... 2 The imvision System... 3 ipatch Panel... 3 imvision Controller... 3 Ordering Panels in

More information

Cisco UCS S3260 System Storage Management

Cisco UCS S3260 System Storage Management Storage Server Features and Components Overview, page 1 Cisco UCS S3260 Storage Management Operations, page 9 Disk Sharing for High Availability, page 10 Storage Enclosure Operations, page 15 Storage Server

More information

Dell PowerVault MD3460 Series Storage Arrays Deployment Guide

Dell PowerVault MD3460 Series Storage Arrays Deployment Guide Dell PowerVault MD3460 Series Storage Arrays Deployment Guide Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make better use of your computer. CAUTION: A CAUTION

More information

Virtual Storage Console 5.0 for VMware vsphere Performing Basic Tasks

Virtual Storage Console 5.0 for VMware vsphere Performing Basic Tasks IBM System Storage N series Virtual Storage Console 5.0 for VMware vsphere Performing Basic Tasks SC27-6638-00 Table of Contents 3 Contents Preface... 5 Supported features... 5 Websites... 5 Getting information,

More information

NovaScale 5xx5 NOVASCALE. Cabling Guide REFERENCE 86 A1 92ER 03

NovaScale 5xx5 NOVASCALE. Cabling Guide REFERENCE 86 A1 92ER 03 NovaScale 5xx5 Cabling Guide NOVASCALE REFERENCE 86 A1 92ER 03 BLANK NOVASCALE NovaScale 5xx5 Cabling Guide Hardware September 2007 BULL CEDOC 357 AVENUE PATTON B.P.20845 49008 ANGERS CEDEX 01 FRANCE REFERENCE

More information

HPE Insight Online User Guide

HPE Insight Online User Guide HPE Insight Online User Guide Document Release Date: October 2017 Software Release Date: October 2017 Legal Notices Warranty The only warranties for Hewlett Packard Enterprise Development LP products and

More information

Dell SCv300 and SCv320 Expansion Enclosure Owner's Manual

Dell SCv300 and SCv320 Expansion Enclosure Owner's Manual Dell SCv300 and SCv320 Expansion Enclosure Owner's Manual Regulatory Model: E03J, E04J Regulatory Type: E03J001, E04J001 Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that

More information

IBM System Storage EXP3000 Direct Attach Interoperability Matrix

IBM System Storage EXP3000 Direct Attach Interoperability Matrix IBM ystem torage EXP3000 Direct Attach Interoperability Matrix Revision Date: April 13, 2010 What s new in the EXP3000 Interoperability Matrix? April 13, 2010: - Added support for 2TB ATA disk drive. -

More information

IBM 1735 Rack-Based Local Console Switches (Withdrawn) Product Guide

IBM 1735 Rack-Based Local Console Switches (Withdrawn) Product Guide IBM 1735 Rack-Based Local Console Switches (Withdrawn) Product Guide The family of IBM rack-based local console switches is designed to provide exceptional scalability and flexibility in managing data

More information

BA350 LA Modular Storage Shelf User s Guide

BA350 LA Modular Storage Shelf User s Guide BA350 LA Modular Storage Shelf User s Guide Order Number: EK 350LA UG 001 This manual describes the BA350 LA storage shelf and the rules for configuring the shelf to include power, system building blocks

More information

Internal Cabling Guide for the HP Smart Array 6400 Series Controller on an HP Integrity Server rx7620

Internal Cabling Guide for the HP Smart Array 6400 Series Controller on an HP Integrity Server rx7620 Internal Cabling Guide for the HP Smart Array 6400 Series Controller on an HP Integrity Server rx7620 May 2004 (Second Edition) Part Number 5990-8201 2004 Hewlett-Packard Development Company, L.P. Microsoft

More information

Overview. About the Cisco UCS S3260 System

Overview. About the Cisco UCS S3260 System About the Cisco UCS S3260 System, on page 1 How to Use This Guide, on page 3 Cisco UCS S3260 System Architectural, on page 5 Connectivity Matrix, on page 7 Deployment Options, on page 7 Management Through

More information

SAS to SAS/SATA JBOD Subsystem. User Manual. Revision 1.1

SAS to SAS/SATA JBOD Subsystem. User Manual. Revision 1.1 SAS to SAS/SATA JBOD Subsystem Revision 1.1 Table of Contents Chapter 1 Introduction... 3 1.1 Features... 4 1.2 Technical Specifications... 5 1.3 Unpacking the JBOD Expansion Chassis... 6 1.4 Identifying

More information

OnCommand Unified Manager 6.1 Administration Guide

OnCommand Unified Manager 6.1 Administration Guide IBM System Storage N series OnCommand Unified Manager 6.1 Administration Guide SC27-6627-00 Table of Contents 3 Contents Preface... 7 Supported features... 7 Websites... 7 Getting information, help, and

More information

Before you begin. Unpack & Prepare. Install Hardware. Connect Drive Trays. Apply Power. Connect Data Hosts. Choose Management Method

Before you begin. Unpack & Prepare. Install Hardware. Connect Drive Trays. Apply Power. Connect Data Hosts. Choose Management Method Before you begin Installation and Setup Instructions for E-Series -Drive and 4-Drive Trays E700 and E5600 controller-drive trays DE600 and DE5600 expansion drive trays Unpack & Prepare Install Hardware

More information

Overview. Cisco UCS Manager User Documentation

Overview. Cisco UCS Manager User Documentation Cisco UCS Manager User Documentation, page 1 Infrastructure Management Guide, page 2 Cisco Unified Computing System, page 3 Cisco UCS Building Blocks and Connectivity, page 5 Cisco UCS Manager User Documentation

More information

NetApp HCI Network Setup Guide

NetApp HCI Network Setup Guide Technical Report NetApp HCI Network Setup Guide Version 1.2 Aaron Patten, NetApp April 2018 TR-4679 TABLE OF CONTENTS 1 Introduction... 4 2 Hardware... 4 2.1 Node and Chassis Layout... 4 2.2 Node Types...

More information

apple Service Source Xserve RAID Xserve RAID and Xserve RAID (SFP) Updated: 25 May Apple Computer, Inc. All rights reserved.

apple Service Source Xserve RAID Xserve RAID and Xserve RAID (SFP) Updated: 25 May Apple Computer, Inc. All rights reserved. apple Service Source Xserve RAID Xserve RAID and Xserve RAID (SFP) Updated: 25 May 2004 2003 Apple Computer, Inc. All rights reserved. apple Service Source Basics Xserve RAID 2003 Apple Computer, Inc.

More information

SAS to SAS/SATA JBOD Subsystem. User Manual. Revision 1.1

SAS to SAS/SATA JBOD Subsystem. User Manual. Revision 1.1 SAS to SAS/SATA JBOD Subsystem Revision 1.1 Table of Contents Chapter 1 Introduction... 3 1.1 Features... 4 1.2 Technical Specifications... 5 1.3 Unpacking the JBOD Expansion Chassis... 6 1.4 Identifying

More information

Hardware Installation Guide Installation (x3350)

Hardware Installation Guide Installation (x3350) Title page Nortel Application Gateway 2000 Nortel Application Gateway Release 6.3 Hardware Installation Guide Installation (x3350) Document Number: NN42400-300 Document Release: Standard 04.03 Date: January

More information

Dell MD Series Storage Arrays. Information Update

Dell MD Series Storage Arrays. Information Update Dell MD Series Storage Arrays Information Update Notes, cautions, and warnings NOTE: A NOTE indicates important information that helps you make better use of your product. CAUTION: A CAUTION indicates

More information

Cisco UCS S3260 System Storage Management

Cisco UCS S3260 System Storage Management Storage Server Features and Components Overview, page 1 Cisco UCS S3260 Storage Management Operations, page 9 Disk Sharing for High Availability, page 10 Storage Enclosure Operations, page 15 Storage Server

More information

IBM TotalStorage DS300 and DS400 Quick Installation Guide

IBM TotalStorage DS300 and DS400 Quick Installation Guide IBM TotalStorage DS300 and DS400 Quick Installation Guide Before using this information and the product it supports, read the IBM Statement of Limited Warranty in the IBM TotalStorage DS300 and DS400 Warranty

More information

N6000 Series Hardware and Service Guide

N6000 Series Hardware and Service Guide IBM System Storage N6000 Series Hardware and Service Guide Covering the N6040, N6060 and N6070 models GC53-1142-07 IBM System Storage N6000 Series Hardware and Service Guide Covering the N6040, N6060

More information

esata II PCIe i/e Quick Installation Guide

esata II PCIe i/e Quick Installation Guide esata II PCIe i/e Quick Installation Guide Introducing the esata II PCIe i/e The esata II PCIe i/e is an ultra high-speed dual channel Serial ATA Generation 2 controller for use in PCI Express enabled

More information

Firmware Version 2.5 March th Avenue SE Calgary, AB, T2G 1W4 Canada. Phone: (403) Fax: (403)

Firmware Version 2.5 March th Avenue SE Calgary, AB, T2G 1W4 Canada. Phone: (403) Fax: (403) User s Guide Firmware Version. March 007 9 7 th Avenue SE Calgary, AB, TG W Canada Phone: (0) -80 Fax: (0) 87-8 E-mail: support@pathwayconnect.com www.pathwayconnect.com Table of Contents About The DMX

More information

GW2000h w/gw175h/q F1 specifications

GW2000h w/gw175h/q F1 specifications Product overview The Gateway GW2000h w/ GW175h/q F1 maximizes computing power and thermal control with up to four hot-pluggable nodes in a space-saving 2U form factor. Offering first-class performance,

More information

Voter Remote Interface (VRI) for the Raytheon JPS Communications SNV-12 Signal-and-Noise Voter

Voter Remote Interface (VRI) for the Raytheon JPS Communications SNV-12 Signal-and-Noise Voter Voter Remote Interface (VRI) for the Raytheon JPS Communications SNV-12 Signal-and-Noise Voter Instruction Manual Issue 1 Rev 9, April 2015 Part Number FI-20080219 Fial Incorporated 710 Center Street Oregon

More information

esata II PCIe i/e Quick Installation Guide

esata II PCIe i/e Quick Installation Guide Introduction esata II PCIe i/e Quick Installation Guide The esata II PCIe i/e is an ultra high-speed dual channel Serial ATA Generation 2 controller for use in PCI Express enabled systems. Features and

More information

IBM System Storage EXP3000 Interoperability Matrix IBM System Storage EXP3000 Direct Attach Interoperability Matrix

IBM System Storage EXP3000 Interoperability Matrix IBM System Storage EXP3000 Direct Attach Interoperability Matrix IBM ystem torage EXP3000 Interoperability Matrix - 1 - IBM ystem torage EXP3000 Direct Attach Interoperability Matrix Last Revised: March 3, 2008 IBM ystem torage EXP3000 Interoperability Matrix - 2 -

More information

StorageGRID Webscale 10.4 Appliance Installation and Maintenance Guide

StorageGRID Webscale 10.4 Appliance Installation and Maintenance Guide StorageGRID Webscale 10.4 Appliance Installation and Maintenance Guide April 2017 215-11696_A0 doccomments@netapp.com Table of Contents 3 Contents Safety notices... 5 StorageGRID Webscale appliance overview...

More information

T Series BIOS BIOS SETUP UTILITY

T Series BIOS BIOS SETUP UTILITY BIOS SECTION T4010 LifeBook T Series Tablet PC T Series BIOS BIOS SETUP UTILITY The BIOS Setup Utility is a program that sets up the operating environment for your tablet. Your BIOS is set at the factory

More information

A33606-PCI-01 SAS-2 Expander User Manual. Version: Document Number:

A33606-PCI-01 SAS-2 Expander User Manual. Version: Document Number: A33606-PCI-01 SAS-2 Expander User Manual Version: C Document Number: 90-000186 A33606-PCI-01 SAS-2 Expander User Manual DOCUMENT 90-000186, VERSION C (1/15/2011) This document describes Astek s 36-port

More information

Remote Access Servers ( Ethernet & Token Ring )

Remote Access Servers ( Ethernet & Token Ring ) LRA502A-ET-R5 LRA504A-ET-R5 LRA508A-ET-R5 LRA502A-TR-R4 LRA504A-TR-R4 LRA508A-TR-R4 Remote Access Servers ( Ethernet & Token Ring ) Installation Guide Black Box Corporation, 1000 Park Drive, Lawrence PA.

More information

apple Service Source Xserve RAID 17 March Apple Computer, Inc. All rights reserved.

apple Service Source Xserve RAID 17 March Apple Computer, Inc. All rights reserved. apple Service Source Xserve RAID 17 March 2003 2003 Apple Computer, Inc. All rights reserved. apple Service Source Basics Xserve RAID 2003 Apple Computer, Inc. All rights reserved. Overview Xserve RAID

More information

IBM Netfinity High-Availability Cluster Solutions Using the IBM ServeRAID II Ultra SCSI Adapter. Installation and User's Guide

IBM Netfinity High-Availability Cluster Solutions Using the IBM ServeRAID II Ultra SCSI Adapter. Installation and User's Guide IM Netfinity High-vailability Cluster Solutions Using the IM ServeRID II Ultra SCSI dapter Installation and User's Guide IM IM IM Netfinity High-vailability Cluster Solutions Using the IM ServeRID II

More information

Dell PowerVault MD3060e Storage Enclosure Owner's Manual

Dell PowerVault MD3060e Storage Enclosure Owner's Manual Dell PowerVault MD3060e Storage Enclosure Owner's Manual Regulatory Model: E08J Series Regulatory Type: E08J001 Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you

More information

Virtual Storage Console 5.0 for VMware vsphere Installation and Administration Guide

Virtual Storage Console 5.0 for VMware vsphere Installation and Administration Guide IBM System Storage N series Virtual Storage Console 5.0 for VMware vsphere Installation and Administration Guide GC52-1349-08 Table of Contents 3 Contents Preface... 9 Supported features... 9 Websites...

More information

esata II 2-Port ExpressCard Quick Installation Guide

esata II 2-Port ExpressCard Quick Installation Guide esata II 2-Port ExpressCard Quick Installation Guide Introducing the esata II 2-Port ExpressCard The esata II 2-Port ExpressCard is an ultra high-speed dual channel Serial ATA Generation 2 controller.

More information

3 Here is a short overview of the specifications. A link to a data sheet with full specification details is given later in this web based training

3 Here is a short overview of the specifications. A link to a data sheet with full specification details is given later in this web based training 1 Welcome to this web based training session. This presentation provides you an introduction to the Fujitsu ETERNUS JX40. The JX40 is a passive direct server attached drive extension offering extension

More information

1 Getting Started Installing & Configuring

1 Getting Started Installing & Configuring Before you begin Installation and Setup Instructions for E-Series 60-Drive Trays E760 and E5660 controller-drive trays DE6600 expansion drive trays Unpack & Prepare Install Hardware Connect Drive Trays

More information

Multi Amplifier Remote Control (MARC) Software QUICK START GUIDE 1.0.0

Multi Amplifier Remote Control (MARC) Software QUICK START GUIDE 1.0.0 Multi Amplifier Remote Control (MARC) Software QUICK START GUIDE 1.0.0 Welcome to Dynacord s Multi Amplifier Remote Control (MARC) Quick Start Guide. We want you to get the most from your Dynacord amplifiers

More information

Linksys Stackable Switches

Linksys Stackable Switches TECHNICAL BULLETIN Linksys Stackable Switches How to Build Stacks and Understand Their Operation This document describes how to stack Linksys switches and covers advanced stacking information, as well

More information

HP LeftHand P4000 Virtual SAN Appliance in an HP BladeSystem environment solution guide

HP LeftHand P4000 Virtual SAN Appliance in an HP BladeSystem environment solution guide HP LeftHand P4000 Virtual SAN Appliance in an HP BladeSystem environment solution guide AT459-96002 Part number: AT459-96002 First edition: April 2009 Legal and notice information Copyright 2009 Hewlett-Packard

More information

IBM Systems. Quick start guide for IBM System p5 505 ( )

IBM Systems. Quick start guide for IBM System p5 505 ( ) IBM Systems Quick start guide for IBM System p5 505 (9115-505) 1 Before you begin This Quick start guide contains an abbreviated set of setup instructions designed to help you quickly unpack and set up

More information