1 IMPLEMENTATION GUIDE EMC VSPEX END-USER COMPUTING Citrix XenDesktop 7.5 and VMware vsphere with EMC XtremIO Enabled by EMC VNX and EMC Data Protection EMC VSPEX Abstract This describes the high-level steps required to deploy an EMC VSPEX End-User Computing solution for Citrix XenDesktop and VMware vsphere enabled by EMC XtremIO, EMC VNX storage, and EMC Data Protection. September 2014

2 Copyright 2014 EMC Corporation. All rights reserved. Published in the USA. Published September 2014 EMC believes the information in this publication is accurate as of its publication date. The information is subject to change without notice. The information in this publication is provided as is. EMC Corporation makes no representations or warranties of any kind with respect to the information in this publication, and specifically disclaims implied warranties of merchantability or fitness for a particular purpose. Use, copying, and distribution of any EMC software described in this publication requires an applicable software license. EMC 2, EMC, and the EMC logo are registered trademarks or trademarks of EMC Corporation in the United States and other countries. All other trademarks used herein are the property of their respective owners. For the most up-to-date listing of EMC product names, see EMC Corporation Trademarks on EMC.com. EMC VSPEX End-User Computing Enabled by EMC VNX and EMC Data Protection Part Number H

3 Contents Contents Chapter 1 Introduction 9 Purpose of this guide Business value Scope Audience Terminology Chapter 2 Before You Start 13 Overview Pre-deployment tasks Deployment workflow Essential reading VSPEX Solution Overview VSPEX Design Guide VSPEX Proven Infrastructure Guide RSA SecurID for VSPEX end-user computing guide Deployment prerequisites Chapter 3 Solution Overview 19 Overview VSPEX Proven Infrastructures Solution architecture High-level architecture Logical architecture Summary of key components Chapter 4 Solution Implementation 27 Overview Network implementation Configuring the infrastructure network Configuring the VLANs Configuring the storage network Completing the network cabling Preparing and configuring the storage arrays Preparing and installing XtremIO

4 Contents Setting up the initial XtremIO configuration Configuring XtremIO event handlers Provisioning storage for VMFS datastores Preparing the VNX Setting up the initial VNX configuration Configuring VNX Fast Cache Provisioning optional VNX storage for user data Configuring FAST VP for user data (optional) VSPEX private cloud requirements Citrix ShareFile requirements Installing and configuring the vsphere hosts Installing vsphere Configuring vsphere networking Connecting vsphere datastores Optimizing vsphere for XtremIO Installing and configuring the SQL Server database VMware vcenter Server deployment Installing and configuring XenDesktop Desktop Delivery Controllers Installing server-side components of XenDesktop Configuring a site Adding a second controller Installing Citrix Studio Preparing the master virtual machine Provisioning the virtual desktops Installing and configuring Citrix Provisioning Services Configuring a PVS server farm Adding a second PVS server Creating a PVS store Configuring inbound communication Configuring a bootstrap file Configuring boot options 66 and 67 on DHCP server Preparing the master virtual machine Provisioning the virtual desktops Setting up EMC Avamar Avamar configuration overview Configuring Group Policy object (GPO) additions for Avamar Windows security for Avamar client service Defining Avamar datasets Defining Avamar backup schedules

5 Contents Adjusting the maintenance window schedule Defining Avamar retention policies Creating an Avamar Group and Group Policy Activating XenDesktop clients (desktops) Chapter 5 Solution Verification 73 Overview Post-installation checklist Deploy and test a single virtual desktop Verify the redundancy of the solution components Chapter 6 Reference Documentation 77 EMC documentation Other documentation Appendix A Configuration Worksheet 81 Customer Configuration Worksheet

6 Contents Figures Figure 1. VSPEX Proven Infrastructures Figure 2. Architecture of the validated solution Figure 3. Logical architecture for both block and file storage Figure 4. Sample Ethernet network architecture Figure 5. Sample FC network architecture Figure 6. XtremIO Display Event Handlers button Figure 7. XtremIO Edit Event Handler window Figure 8. Storage System Properties dialog box Figure 9. Creating FAST Cache dialog box Figure 10. Storage Pool Properties dialog box Figure 11. Manage Auto-Tiering Window Figure 12. Configure Bootstrap dialog box Figure 13. Configuring Windows Folder Redirection Figure 14. Opening the Mapped Drive Properties dialog box Figure 15. Creating a Windows network drive mapping for user files Figure 16. Configuring drive mapping common settings Figure 17. Creating a Windows network drive mapping for user profile data Figure 18. Configuring Windows Folder Redirection Figure 19. Configuring Avamar dataset settings Figure 20. User profile dataset Exclusion settings Figure 21. Select Plug-in Type option Figure 22. Volume Freezing Options Figure 23. Avamar default Backup/Maintenance Windows schedule Figure 24. Avamar modified Backup/Maintenance Windows schedule Figure 25. Creating a new Avamar backup group Figure 26. New Group window Figure 27. Select An Existing Schedule Figure 28. Avamar Enterprise Manager Dashboard Figure 29. Avamar Client Manager Figure 30. Client Information menu Figure 31. Directory Service dialog box Figure 32. EMC Avamar Client Manager with Active Directory information Figure 33. VSPEX virtual desktops Figure 34. Selected virtual desktops Figure 35. Select Groups window Figure 36. Activate domain Figure 37. Show Clients for Activation window Figure 38. Avamar Client Manager with activated clients

7 Contents Figure 39. Opening attachments in a PDF file Tables Table 1. Terminology Table 2. Tasks for pre-deployment Table 3. Deployment workflow Table 4. Deployment prerequisites checklist Table 5. VSPEX solution components Table 6. Implementation process overview Table 7. Tasks for switch and network configuration Table 8. Tasks for storage configuration Table 9. Volumes on XtremIO for storing virtual desktops Table 10. Create block-based RAID 6 storage pool Table 11. Configure LUNs for NAS pool Table 12. Infrastructure server minimum requirements Table 13. Minimum hardware resources for ShareFile StorageZones with Storage Center Table 14. Recommended VNX storage for ShareFile StorageZones CIFS share Table 15. Tasks for server installation Table 16. Tasks for SQL Server database setup Table 17. Tasks for vcenter configuration Table 18. Tasks for XenDesktop controller setup Table 19. Tasks for XenDesktop controller setup Table 20. Tasks for Avamar integration Table 21. Tasks for testing the installation Table 22. Common server information Table 23. vsphere Server information Table 24. XtremIO array information Table 25. VNX array information Table 26. Network infrastructure information Table 27. VLAN information Table 28. Service accounts

8 Contents 8

9 Chapter 1: Introduction Chapter 1 Introduction This chapter presents the following topics: Purpose of this guide Business value Scope Audience Terminology

10 Chapter 1: Introduction Purpose of this guide Business value The EMC VSPEX End-User Computing Proven Infrastructure provides the customer with a modern system capable of hosting a large number of virtual desktops at a consistent performance level. This VSPEX End-User Computing solution for Citrix XenDesktop 7.5 runs on a VMware vsphere virtualization layer backed by the high availability EMC XtremIO family, which provides the storage. In this solution, the desktop virtualization infrastructure components are layered on a VSPEX Private Cloud for VMware vsphere Proven Infrastructure, while the desktops are hosted on dedicated resources. The compute and network components, which are defined by the VSPEX partners, are designed to be redundant and sufficiently powerful to handle the processing and data needs of a large virtual desktop environment. EMC XtremIO solutions provide storage for virtual desktops, EMC VNX solutions provide storage for user data, EMC Avamar data protection solutions provide data protection for Citrix XenDesktop data, and RSA SecurID provides optional secure user authentication functionality. This VSPEX End-User-Computing solution is validated for up to 1,750 Citrix XenDesktop Machine Creation Services (MCS) linked clone or Citrix Provisioning Services (PVS) streamed virtual desktops for a Starter X-Brick and up to 3,500 MCS linked clone or PVS streamed virtual desktops for an X-Brick. These validated configurations are based on a reference desktop workload and form the basis for creating cost-effective, custom solutions for individual customers. An end-user computing or virtual desktop infrastructure is a complex system offering. This describes how to implement, with best practices, the resources necessary to deploy an end-user computing solution using Citrix XenDesktop for VMware vsphere enabled by EMC XtremIO, EMC VNX, and EMC Data Protection. Employees are more mobile than ever, and they expect access to business-critical data and applications whenever and wherever they are, and from any device. They want the flexibility to bring their own device to work, meaning IT departments are increasingly investigating and supporting Bring Your Own Device (BYOD) initiatives. This adds layers of complexity when it comes to safeguarding sensitive information. Deploying a virtual desktop project is one way to do this. Implementing large-scale virtual desktop environments, however, presents many challenges. Administrators must rapidly roll out persistent or non-persistent desktops for all users (task workers, knowledge workers, and power users,) while offering an outstanding user experience that outperforms physical desktops. In addition to performance, a virtual desktop solution must be simple to deploy, manage, and scale with substantial cost savings over physical desktops. Storage is also a critical component of an effective virtual desktop solution. EMC VSPEX Proven Infrastructures are designed to help you address the most serious of IT challenges by creating solutions that are simple, efficient, flexible, and designed to take advantage of the many possibilities that the XtremIO flash technology delivers. 10

11 The business benefits of the VSPEX End-User Computing solution for Citrix XenDesktop include the following: Chapter 1: Introduction An end-to-end virtualization solution to utilize the capabilities of the unified infrastructure components. Efficient virtualization for varied customer user cases of up to 1,750 MCS linked clone or PVS streamed virtual desktops for a Starter X-Brick, and up to 3,500 MCS linked clone or PVS streamed virtual desktops for an X-Brick. Reliable, flexible, and scalable reference architectures. Scope This describes the high-level steps required to deploy the VSPEX End-User Computing solution for Citrix XenDesktop 7.5. It provides a deployment example of a virtual desktop storage on EMC XtremIO and user data storage on a next-generation VNX storage array. The infrastructure servers required for this solution are designed to be layered on a VSPEX Private Cloud for VMware vsphere Proven Infrastructure. The same principles and guidelines apply to both the XtremIO and VNX arrays that have been validated as part of the EMC VSPEX program. The optional RSA SecurID secure user authentication solution for XenDesktop is described in a separate document, Securing EMC VSPEX End-User Computing with RSA SecurID: Citrix XenDesktop 7 and VMware vsphere 5.1 for up to 2,000 Virtual Desktops Design Guide. Audience This guide is intended for internal EMC personnel and qualified EMC VSPEX Partners. The guide assumes that VSPEX partners who intend to deploy this VSPEX Proven Infrastructure for Citrix XenDesktop have the necessary training and background to install and configure an end-user computing solution based on Citrix XenDesktop with VMware vsphere as the hypervisor, XtremIO and VNX series storage systems, and associated infrastructure. Readers should also be familiar with the infrastructure and database security policies of the customer installation. This guide provides external references where applicable. EMC recommends that partners implementing this solution are familiar with these documents. For details, refer to Essential reading and Chapter 6: Reference Documentation. 11

12 Chapter 1: Introduction Terminology Table 1 lists the terminology used in this guide. Table 1. Terminology Term Data deduplication PVS streamed desktops MCS linked clones Reference architecture Reference workload Storage Processor (SP) Storage Controller (SC) Virtual Desktop Infrastructure (VDI) XtremIO Management Server (XMS) Definition A feature of the XtremIO array that reduces physical storage utilization by eliminating redundant blocks of data. Desktops provisioned as PVS streamed desktops that stream their base image data from Citrix Provisioning Services (PVS) servers, writing any changes to a local write cache or Citrix Personal vdisk depending on the desktop configuration. Desktops provisioned as MCS linked clones that share a common base image within a desktop pool and therefore have a minimal storage footprint The validated architecture that supports this VSPEX end-usercomputing solution at two particular points of scale that is 1,750 MCS linked clone or PVS streamed virtual desktops, and 3,500 MCS linked clone or PVS streamed virtual desktops. For VSPEX end-user computing solutions, the reference workload is defined as a single virtual desktop (the reference virtual desktop) with the workload characteristics indicated in the Design Guide. By comparing the customer s actual usage to this reference workload, you can extrapolate which reference architecture to choose as the basis for the customer s VSPEX deployment. Refer to the EMC VSPEX END-USER COMPUTING: Citrix XenDesktop 7.5 and VMware vsphere with EMC XtremIO Enabled by EMX VNX and EMC Data Protection Design Guide for details. The compute component of the VNX storage array. SPs are used for all aspects of data moving into, out of, and between VNX arrays The computer component of the XtremIO storage array. SCs are used for all aspects of data moving into, out of, and between XtremIO arrays. Decouples the desktop from the physical machine. In a VDI environment, the desktop operating system (OS) and applications reside inside a virtual machine running on a host computer, with data residing on shared storage. Users access their virtual desktop from any computer or mobile device over a private network or internet connection. Used to manage the XtremIO array, and is deployed as a virtual machine. The XMS is deployed using an Open Virtualization Alliance (OVA) package. 12

13 Chapter 2: Before You Start Chapter 2 Before You Start This chapter presents the following topics: Overview Pre-deployment tasks Deployment workflow Essential reading Deployment prerequisites

14 Chapter 2: Before You Start Overview This chapter provides an overview of important information which you need to be aware of, documents with which you need to be familiar, and tasks you need to perform before you start implementing your VSPEX End-User Computing with Citrix XenDesktop solution. The Design Guide for this solution: EMC VSPEX END-USER COMPUTING: Citrix XenDesktop 7.5 and VMware vsphere with EMC XtremIO Enabled by EMX VNX and EMC Data Protection describes how to design and size your solution, allocate resources following best practices, and use all the benefits that VSPEX offers. The deployment examples in this are based on the recommendations and examples in the Design Guide. Pre-deployment tasks Pre-deployment tasks include procedures that do not directly relate to environment installation and configuration, but you will need the results from these tasks at the time of installation. Examples of pre-deployment tasks are the collection of host names, IP addresses, VLAN IDs, license keys, installation media, and so on. You should perform these tasks before the customer visit to reduce the amount of time required on site. Table 2. Tasks for pre-deployment Task Description Reference Gather documents Gather tools Gather data Gather the related documents listed in Essential reading and Reference Documentation. These are used throughout this document to provide details on setup procedures, sizing, and deployment best practices for the various components of the solution. Gather the required and optional tools for the deployment. Use Table 4 to confirm that all equipment, software, and appropriate licenses are available before the deployment process. Collect the customer-specific configuration data for networking, arrays, accounts, and so on. Enter this information into the Customer Configuration Worksheet for reference during the deployment process. In addition, for the most comprehensive array-specific information, complete the relevant XtremIO pre-installation checklist and VNX worksheet. These documents are available on EMC Online Support. Essential reading Reference Documentation Deployment prerequisites checklist XtremIO Storage Array Pre-Installation Checklist VNX Installation Assistant for File/Unified Worksheet Customer Configuration Worksheet 14

15 Chapter 2: Before You Start Deployment workflow To design and implement your end-user computing solution, refer to the process flow in Table 3. Table 3. Deployment workflow Step Action 1 Use the Customer Sizing Worksheet in the Design Guide to collect customer requirements. 2 Use the EMC VSPEX Sizing Tool to determine the recommended VSPEX reference architecture for your end-user computing solution, based on the user requirements collected in Step 1. For more information about the Sizing Tool, refer to the EMC VSPEX Sizing Tool portal. Note: If the Sizing Tool is not available, you can manually size the application using the guidelines in the Design Guide. 3 Use the Design Guide to determine the final design for your VSPEX solution. Note: Ensure that all resource requirements are considered, not just the requirements for end-user computing. 4 Select and order the correct VSPEX reference architecture and Proven Infrastructure. Refer to the VSPEX Proven Infrastructure Guide in Essential reading for guidance on selecting a Private Cloud Proven Infrastructure. 5 Follow this to deploy and test your VSPEX solution. Note: If you already have a VSPEX Proven Infrastructure environment, you can skip the implementation steps that are already completed. Essential reading EMC recommends that you read the following documents, available from the VSPEX space in the EMC Community Network, on EMC.com, or from the VSPEX Proven Infrastructure partner portal. VSPEX Solution Overview VSPEX Design Guide Refer to the EMC VSPEX End-User Computing Solution Overview. Refer to the Citrix XenDesktop 7.5 and VMware vsphere with XtremIO Design Guide. 15

16 Chapter 2: Before You Start VSPEX Proven Infrastructure Guide RSA SecurID for VSPEX end-user computing guide Refer to the EMC VSPEX Private Cloud: VMware vsphere 5.5 for up to 1,000 Virtual Machines proven Infrastructure Guide. Refer to the Securing EMC VSPEX End-User Computing with RSA SecurID: Citrix XenDesktop 7 and VMware vsphere 5.1 for up to 2,000 Virtual Desktops Design Guide. Deployment prerequisites Table 4 itemizes the hardware, software, and license requirements to configure the solution. Visit EMC Online Support for more information on these prerequisites. Table 4. Deployment prerequisites checklist Requirement Hardware Software Description Physical servers with sufficient capacity to host the virtual desktops, as recommended in the Design Guide VMware vsphere servers to host virtual infrastructure servers Networking switch port capacity and capabilities as required for end-user computing EMC XtremIO array with the required configuration EMC VNX multiprotocol storage array with the required disk layout Note: These requirements might be covered by an existing infrastructure. VMware vsphere 5.5 installation media VMware vcenter Server 5.5 installation media EMC XtremIO Management Server OVA file EMC Virtual Storage Integrator (VSI) for VMware vsphere Unified Storage Management EMC VSI for VMware vsphere Storage Viewer EMC PowerPath Viewer EMC PowerPath Virtual Edition (PowerPath/VE) Microsoft Windows Server 2012 R2 installation media (suggested OS for VMware vcenter, Citrix XenDesktop Desktop Delivery Controllers, and Citrix Provisioning Servers) Microsoft Windows 8.1 installation media Microsoft SQL Server 2012 or later installation media Note: This requirement might be covered in the existing infrastructure. 16

17 Chapter 2: Before You Start Requirement Licenses Licenses Description VMware vsphere 5.5 license keys (for infrastructure server hosts) VMware vcenter Server 5.5 license key VMware vsphere Desktop license keys (for virtual desktop hosts) Microsoft Windows Server 2012 R2 Standard Edition (or later) license keys Note: This requirement might be covered by an existing Microsoft Key Management Server (KMS). Microsoft Windows 8.1 license keys Note: This requirement might be covered by an existing Microsoft Key Management Server (KMS). Microsoft SQL Server 2012 license key Note: This requirement might be covered by an existing license. EMC PowerPath Virtual Edition license files 17

18 Chapter 2: Before You Start 18

19 Chapter 3: Solution Overview Chapter 3 Solution Overview This chapter presents the following topics: Overview VSPEX Proven Infrastructures Solution architecture Summary of key components

20 Chapter 3: Solution Overview Overview This chapter provides an overview of the VSPEX End-User Computing for Citrix XenDesktop on VMware vsphere solution and the key technologies used in the solution. The solution has been designed and proven by EMC to provide the desktop virtualization, server, network, storage, and data protection resources to support reference architectures of up to 1,750 MCS linked clone or PVS streamed virtual desktops for a Starter X-Brick, and up to 3,500 MCS linked clone or PVS streamed virtual desktops for an X-Brick. Although the desktop virtualization infrastructure components of the solution shown in Figure 3 are designed to be layered on a VSPEX Private Cloud solution, the reference architectures do not include configuration details for the underlying Proven Infrastructure. Refer to the VSPEX Proven Infrastructure Guide listed in Essential reading for information on configuring the required infrastructure components. VSPEX Proven Infrastructures EMC has joined forces with the industry-leading providers of IT infrastructure to create a complete virtualization solution that accelerates the deployment of the private cloud and Citrix XenDesktop virtual desktops. VSPEX enables customers to accelerate their IT transformation with faster deployment, greater simplicity and choice, higher efficiency, and lower risk, instead of facing the challenges and complexity of building an IT infrastructure themselves. VSPEX validation by EMC ensures predictable performance and enables customers to select technology that uses their existing or newly acquired IT infrastructure while eliminating planning, sizing, and configuration burdens. VSPEX provides a virtual infrastructure for customers who want the simplicity that is characteristic of truly converged infrastructures, with more choice in individual stack components. VSPEX Proven Infrastructures, as shown in Figure 1, are modular, virtualized infrastructures validated by EMC and delivered by EMC VSPEX partners. They include virtualization, server, network, storage, and data protection layers. Partners can choose the virtualization, server, and network technologies that best fit a customer s environment, while the high availability EMC XtremIO and VNX family of storage systems and EMC data protection technologies provide the storage and data protection layers. 20

21 Chapter 3: Solution Overview Figure 1. VSPEX Proven Infrastructures Solution architecture High-level architecture The EMC VSPEX End-User Computing for Citrix XenDesktop solution provides a complete system architecture capable of supporting up to 1,750 MCS linked clone or PVS streamed virtual desktops for a Starter X-Brick, and up to 3,500 MCS linked clone or PVS streamed virtual desktops for an X-Brick. The solution supports block storage for virtual desktops, and optional file storage for user data. Figure 2 shows the high-level architecture of the validated solution. 21

22 Chapter 3: Solution Overview Figure 2. Architecture of the validated solution The solution uses EMC VNX and VMware vsphere to provide the storage and virtualization platforms for a Citrix XenDesktop environment of Microsoft Windows 8.1 virtual desktops provisioned by either MCS or PVS For the solution, we 1 deployed the XtremIO array in multiple configurations to support up to 3,500 virtual desktopswe also deployed next-generation VNX array for hosting user data. The high-availability EMC XtremIO array provides the storage for the desktop virtualization components. The infrastructure services for the solution, as shown in Figure 3, can be provided by existing infrastructure at the customer site, by the VSPEX Private Cloud, or by deploying them as dedicated resources as part of the solution. The virtual desktops, as shown in Figure 3, require dedicated end-user computing resources and are not intended to be layered on a VSPEX Private Cloud. Planning and designing the storage infrastructure for a Citrix XenDesktop environment is critical because the shared storage must be able to absorb large bursts of I/O that occur during a day. These bursts can lead to periods of erratic and unpredictable virtual desktop performance. Users can adapt to slow performance, but unpredictable performance frustrates users and reduces efficiency. To provide predictable performance for end-user computing solutions, the storage system must be able to handle the peak I/O load from the clients while keeping 1 In this guide, "we" refers to the EMC Solutions engineering team that validated the solution. 22

23 Chapter 3: Solution Overview response time to a minimum. This solution uses the EMC XtremIO array to provide the sub-millisecond response times that clients require, while the real-time, inline deduplication features of the platform reduce the amount of physical storage needed. EMC Data Protection and recovery solutions enable user data protection and end-user recoverability. This Citrix XenDesktop solution uses EMC Avamar and its desktop client to achieve this. Logical architecture The EMC VSPEX End-User Computing for Citrix XenDesktop solution supports block storage for the virtual desktops. Figure 3 shows the logical architecture of the solution. Figure 3. Logical architecture for both block and file storage This solution uses two networks, one storage network for carrying virtual desktop and virtual server OS data and one 10 Gb Ethernet network for carrying all other traffic. The storage network uses 8 Gb FC, 10 Gb CEE with FCoE, or 10 Gb Ethernet with iscsi protocol. Note: The solution also supports 1 Gb Ethernet if the bandwidth requirements are met. 23

24 Chapter 3: Solution Overview Summary of key components Table 5 summarizes the key layers used in this solution. The Design Guide provides overviews of the individual components. Table 5. VSPEX solution components VSPEX layer Application layer Virtualization layer Compute layer Network layer Components Citrix XenDesktop 7.1 with: Receiver Storefront Studio Delivery Controller Virtual Delivery Agent (VDA) Server OS machines Desktop OS machines Remote PC Access License Server Citrix Machine Creation Services (MCS) Citrix Provisioning Services (PVS) Citrix Personal vdisk (PvDisk or PvD) Citrix Profile Management VMware vsphere hypervisor with: VMware vsphere VMware vcenter Server VMware vsphere High Availability EMC Virtual Storage Integrator (VSI) VSPEX defines the minimum amount of compute layer resources required but allows the customer to implement the requirements using any server hardware that meets these requirements. VSPEX defines the minimum number of network ports required for the solution and provides general guidance on network architecture, but allows the customer to implement the requirements using any network hardware that meets these requirements. 24

25 Chapter 3: Solution Overview VSPEX layer Storage layer Data protection layer Security layer Components EMC XtremIO series with: EMC XtremIO Management Server EMC Virtual Storage Integrator (VSI) for VMware vsphere VMware vsphere Storage APIs for Array Integration EMC XtremIO Snapshots EMC next-generation VNX series with: EMC Unisphere Management Suite EMC Virtual Storage Integrator (VSI) for VMware vsphere VMware vsphere Storage APIs for Array Integration VMware vsphere Storage APIs for Storage Awareness EMC VNX Snapshots EMC SnapSure EMC VNX Virtual Provisioning EMC FAST Suite FAST Cache and Fully Automated Storage Tiering for Virtual Pools (FAST VP) EMC Avamar RSA SecurID 25

26 Chapter 3: Solution Overview 26

27 Chapter 4 Solution Implementation This chapter presents the following topics: Overview Network implementation Preparing and configuring the storage arrays Installing and configuring the vsphere hosts Installing and configuring the SQL Server database VMware vcenter Server deployment Installing and configuring XenDesktop Desktop Delivery Controllers Installing and configuring Citrix Provisioning Services Setting up EMC Avamar

28 Overview This chapter describes how to implement the reference architecture of the end-user computing solution. If you already have a VSPEX Proven Infrastructure environment, you can skip the sections for the implementation steps already completed. Otherwise, refer to the VSPEX Proven Infrastructure Guide listed in Essential reading for information on configuring the required infrastructure components. Note: This solution requires certain infrastructure services, as shown in Figure 3. These can be provided by existing infrastructure at the customer site, by a VSPEX Private Cloud, or by deploying them as dedicated resources as part of this solution. Table 6 lists the main stages in the solution implementation process, with links to the relevant sections in the chapter. Table 6. Implementation process overview Stage Description Reference 1 Configure the switches and networks and connect to the customer network. 2 Install and configure the XtremIO and VNX arrays. 3 Configure the virtual machine datastores. Network implementation Preparing and configuring the storage array Preparing and configuring the storage array 4 Install and configure the servers. Installing and configuring the vsphere hosts 5 Set up SQL Server (used by vcenter, XenDesktop, and Citrix Provisioning Services). 6 Install and configure vcenter and virtual machine networking. 7 Set up the XenDesktop Desktop Delivery Controllers 8 Set up Citrix Provisioning Services (PVS) Installing and configuring the SQL Server database Installing and configuring the vsphere hosts Installing and configuring XenDesktop Desktop Delivery Controllers Installing and configuring Citrix Provisioning Services 9 Set up EMC Avamar Setting up EMC Avamar 28

29 Network implementation This section describes the requirements for preparing the network infrastructure required to support this solution. Table 7 summarizes the tasks to be completed, with references for further information. Table 7. Tasks for switch and network configuration Task Description Reference Configure the infrastructure network Configure the VLANs Configure the storage network Complete the network cabling Configure the storage array and vsphere host infrastructure networking. Configure private and public VLANs as required. Configure FC/FCoE switch ports and zoning for vsphere hosts and the storage array. Connect the switch interconnect ports, VNX ports, and vsphere server ports. Configuring the infrastructure network Vendor s switch configuration guide Configuring the storage network Vendor s switch configuration guide Completing the network cabling Configuring the infrastructure network The infrastructure network requires redundant network links for each vsphere host, the storage array, switch interconnect ports, and switch uplink ports. This configuration provides both redundancy and additional network bandwidth. This configuration is required regardless of whether the network infrastructure for the solution already exists or is being deployed with other components of the solution. Figure 4 shows a sample redundant Ethernet infrastructure for the VNX used in this solution. This solution uses redundant switches and links to ensure that no single point of failure exists in network connectivity. 29

30 Figure 4. Sample Ethernet network architecture 30

31 Configuring the VLANs Configuring the storage network Ensure that there are adequate switch ports for the storage array and vsphere hosts. EMC recommends that you configure the vsphere hosts with a minimum of two VLANs: Client access network: Virtual machine networking and Common Internet File System (CIFS) traffic (these are customer-facing networks, which can be separated if needed) Management network: vsphere management and VMware vmotion (private network) This solution requires a dedicated storage network. If iscsi is used to connect vsphere hosts to the XtremIO array, a dedicated VLAN for the storage network is required. If Fibre Channel (FC) or a combination of FC for the XtremIO array and FCoE for vsphere hosts will be used, no additional VLANs are required for the storage network. For the solution tests, we used a FC network. The infrastructure FC network requires redundant FC switches and links for each vsphere host and the storage array. This configuration provides both redundancy and additional storage network bandwidth. We connected each vsphere host to both FC switches, and each switch to each storage processor on the storage array. We then placed each FC connection between the vsphere host and the storage array in a separate FC zone. Figure 5 shows the network architecture used for testing this solution. Figure 5. Sample FC network architecture 31

32 Completing the network cabling Ensure that all solution servers, storage arrays, switch interconnects, and switch uplinks have redundant connections and are plugged into separate switching infrastructures. Also ensure a complete connection is set up to the existing customer network. Note: At this point, the new equipment is connected to the existing customer network. Ensure that unforeseen interactions do not cause service issues on the customer network. Preparing and configuring the storage arrays This section describes how to configure the VNX storage array. In this solution, VNX provides NFS or VMware Virtual Machine File System (VMFS) data storage for VMware hosts. Table 8 shows the tasks for storage configuration. Table 8. Tasks for storage configuration Task Description Reference Preparing and installing XtremIO Setting up the initial XtremIO configuration Configuring XtremIO event handlers Provisioning storage for VMFS datastores Preparing the VNX Setting up the initial VNX configuration Configuring VNX Fast Cache Provisioning optional VNX storage for user data Install the XtremIO hardware according to the product documentation. Configure the IP address information and other key parameters on the XtremIO array. Configure XtremIO event handlers to send notifications concerning array physical space utilization. Create XtremIO volumes that will be presented to the vsphere servers as VMFS datastores hosting the virtual desktops. Install the VNX hardware according to the product documentation. Configure the IP address information and other key parameters on the VNX. Configure FAST Cache. Optionally, configure FAST VP. Create CIFS file systems that will be used to store roaming user profiles and home directories. Configure FAST Cache. Optionally, configure FAST VP. EMC XtremIO Storage Array Hardware Installation and Upgrade Guide EMC XtremIO Storage Array Software Installation and Upgrade Guide Configuring XtremIO event handlers Provisioning storage for VMFS datastores VSPEX Private Cloud Proven Infrastructure Guide VSPEX Private Cloud Proven Infrastructure Guide Configuring VNX Fast Cache Configuring FAST VP for user data (optional) Provisioning optional VNX storage for user data 32

33 Task Description Reference VSPEX private cloud Create additional VMFS datastores to host SQL Server, domain controller, vcenter Server, Citrix XenDesktop Desktop Delivery Controller, and Citrix Provisioning Services virtual machines. Private cloud storage Preparing and installing XtremIO Setting up the initial XtremIO configuration Configuring XtremIO event handlers There are no specific setup steps for this solution. For instructions on assembly, racking, cabling, and powering the XtremIO array, refer to the following documents: EMC XtremIO Storage Array Site Preparation Guide EMC XtremIO Storage Array Pre-Installation Checklist EMC XtremIO Storage Array Software Installation and Upgrade Guide EMC XtremIO Storage Array Hardware Installation and Upgrade Guide After preparing the XtremIO, configure key information about the existing environment so that the storage array can communicate with it. Configure the following common items in accordance with your IT data center policies and existing infrastructure information: Domain Name System (DNS) Network Time Protocol (NTP) XMS network interface Storage network interfaces Storage network IP addresses You can configure XtremIO to send you alerts when Software Minor Cluster events occur, a classification that includes events related to cluster-free capacity. A full list of XtremIO errors and alerts can be found in the EMC XtremIO Storage Array User Guide. To create an event handler that s you when these events occur, complete the following steps: 1. From the XtremIO Storage Management Application, select the Alerts & Events icon 2. In the Alerts & Events window, click Events. 3. Click the Display Event Handlers button in the upper right hand corner, as shown in Figure 6 33

34 Figure 6. XtremIO Display Event Handlers button 4. In the Event Handlers window, click Add. 5. In the Add Event Handler window, select the following, where cluster is the name of the XtremIO cluster as specified during installation, as shown in Figure 7: Category: Software Severity: Minor Entity: Cluster Entity Details: <cluster name> 6. In the same window, select the Send check box then click OK. The alert can also be configured to Send SNMP Trap or Send to Syslog. Figure 7. XtremIO Edit Event Handler window 7. From the XtremIO Storage Management Application, click the Administration icon. 8. On the Administration - Configuration tab, use the Add button to add any addresses that should receive copies of XtremIO alerts. If you have configured the event handler to use either SNMP or Syslog for sending alerts, configure those options if they have not already been configured using the SNMP Configuration or Syslog Configuration tabs as required. 34

35 Provisioning storage for VMFS datastores Complete the following steps in the EMC XtremIO Storage Management Application to configure volumes on the XtremIO array for storing virtual desktops: Perform the following steps to configure the required volumes, as detailed in Table 9 to present to the vsphere servers as VMFS datastores. Two datastore configurations are listed for each desktop type, one that includes the space required to use the Citrix Personal vdisk (PVD) feature, and one that does not for solutions that will not use that component of Citrix XenDesktop. Note that when deploying Citrix desktops using PVS, the following values are configured by default: PVS write cache disk 6 GB Citrix Personal vdisk (PvD) 10 GB If either of these values are changed from the default, the datastore sizes must also be changed as a result. Table 9. Volumes on XtremIO for storing virtual desktops XtremIO configuration Number of desktops Type of desktop Number of volumes Volume size Starter X-Brick 1,750 PVS streamed 7 2,500 GB PVS with PVD streamed MCS linkedclone MCS with PVD linked-clone 5,000 GB GB 2,000 GB X-Brick 3,500 PVS streamed 14 2,500 GB PVS with PVD streamed MCS linkedclone MCS with PVD linked-clone 5,000 GB GB 2,000 GB 1. Click Configuration. 2. In the Volume pane, click Add. 3. In the Add New Volumes window, click Add Multiple. 4. In the Number of Volumes field, type the required number of datastores based on the configuration and number of virtual desktops. In the Name field provide a common LUN name and in the Size field type either 750 GB or 5000 GB as required and click Ok. 35

36 Preparing the VNX Setting up the initial VNX configuration There are no specific setup steps for this solution. For instructions on assembly, racking, cabling, and powering the VNX array, refer to the EMC VNX5400 Unified Installation Guide. After preparing the VNX, configure key information about the existing environment so that the storage array can communicate with it. Configure the following common items in accordance with your IT data center policies and existing infrastructure information: Domain Name System (DNS) Network Time Protocol (NTP) Storage network interfaces Storage network IP address CIFS services and Active Directory (AD) domain membership The reference documents listed in Table 8 provide more information on how to configure the VNX platform. The Design Guide provides information about the disk layout. Configuring VNX Fast Cache To configure FAST Cache on the VNX storage pool for this solution, complete the following steps in Unisphere: 1. To view FAST Cache information for the VNX array: a. In Unisphere, click Properties and select Manage Cache. b. In the Storage System Properties dialog box, as shown in Figure 8, select FAST Cache to view FAST Cache information. Figure 8. Storage System Properties dialog box 2. To create FAST Cache: 36

37 a. Click Create to open the Create FAST Cache dialog box, as shown in Figure 9. Figure 9. Creating FAST Cache dialog box b. Select the required number of disks to be used for FAST Cache. Note: To determine the number of flash drives to use, refer to the Design Guide. c. With Automatic selected, flash drives that will be used for creating FAST Cache are listed in the dialog box. To select the drives manually, select Manual. d. Click OK to create FAST Cache using the selected disks. Note: If a sufficient number of flash drives are not available, an error message appears and FAST Cache cannot be created. e. Enable FAST Cache for the storage pool created for the solution. After FAST Cache is created, it is enabled by default for all new pools created. To enable FAST Cache for an existing pool, select the FAST Cache Enabled option under Advanced in the Storage Pool Properties dialog box. The FAST Cache feature on VNX does not cause an instant performance improvement. The system must collect data about access patterns and promote frequently used information into the cache. This process takes a few hours during which the performance of the array steadily improves. 37

38 Provisioning optional VNX storage for user data If the storage required for user data (that is, roaming user profiles or XenDesktop Profile Management repositories and home directories) does not exist in the production environment already and the optional user data disk pack has been purchased, complete the following steps in Unisphere to configure two CIFS file systems on VNX: 1. Create a block-based RAID 6 storage pool with the characteristics shown in Table 10. Table 10. Create block-based RAID 6 storage pool Configuration Number of drives Drive type 1,750 virtual desktops 24 3,500 virtual desktops 48 2 TB NL-SAS The Design Guide describes the storage layouts. 2. Provision the required LUNs from the pool, as detailed in Table 11, to present to the Data Mover as dvols of a system-defined NAS pool. Table 11. Configure LUNs for NAS pool Configuration Number of LUNs LUN size (TB) 1,750 virtual desktops ,500 virtual desktops Provision four file systems from the NAS pool to be exported as CIFS shares on a CIFS server. For 3,500 desktop configurations, the file systems should be distributed between two CIFS servers. Additionally, the CIFS servers should be distributed among the two active Data Movers on the VNX5400. Configuring FAST VP for user data (optional) You can configure FAST VP to automate data movement between storage tiers in the user data storage pool, which is optional. You can configure FAST VP at the pool level or at the LUN level. Configuring FAST VP at pool level To view and manage FAST VP at the pool level, select the storage pool for the user data and click Properties to open the Storage Pool Properties dialog box. Tier Status shows FAST VP relocation information specific to the pool selected. Tier Details shows the exact distribution of the data. Figure 10 shows the tiering information for a specific FAST VP-enabled pool. 38

39 Figure 10. Storage Pool Properties dialog box You can select scheduled relocation at the pool level from the Auto-Tiering menu. You can set this to either Automatic or Manual. Click Relocation Schedule to open the Manage Auto-Tiering window, as shown in Figure 11. From this window, you can control the Data Relocation Rate. The default rate is set to Medium to avoid significantly affecting host I/O. Note: FAST VP is a completely automated tool and you can schedule relocations to occur automatically. EMC recommends scheduling relocations during off-peak hours to minimize any potential performance impact. Figure 11. Manage Auto-Tiering Window 39

40 VSPEX private cloud requirements This VSPEX End User Computing Proven Infrastructure requires multiple application servers. Unless otherwise specified, all servers use Microsoft Windows Server 2012 R2 as the base OS. Table 12 lists the minimum requirements of each infrastructure server required. Table 12. Infrastructure server minimum requirements Server CPU RAM IOPS Storage capacity Domain controllers (each) 2 vcpus 4 GB GB SQL Server 2 vcpus 6 GB GB vcenter Server 4 vcpus 8 GB GB Citrix XenDesktop Controllers (each) 2 vcpus 8 GB GB Private cloud storage layout This solution requires a 1.5 TB volume to host the infrastructure virtual machines, which can include the VMware vcenter Server, Citrix XenDesktop Controllers, Citrix PVS servers, optional Citrix ShareFile servers, Microsoft Active Directory Server, and Microsoft SQL Server. Citrix ShareFile requirements Table 13 details the minimum requirements for CPU and memory to implement Citrix ShareFile StorageZones with Storage Center. Table 13. Minimum hardware resources for ShareFile StorageZones with Storage Center CPU (cores) Memory (GB) Reference 2 4 Storage Center system requirements on the Citrix edocs website. Citrix ShareFile storage layout ShareFile StorageZones requires a CIFS share to provide private data storage for Storage Center. The VNX, which provides the storage for VSPEX end-user computing solutions, provides both file and block access and an extensive feature set that makes it an ideal choice for ShareFile StorageZones deployments. Table 14 details the recommended VNX storage for the StorageZones CIFS share. Table 14. Recommended VNX storage for ShareFile StorageZones CIFS share CIFS share for (number of users) Configuration Notes 1750 users Twenty-four 2 TB, 7,200 rpm 3.5-inch NL-SAS disks (6+2 RAID 6) 3500 users Forty-eight 2 TB, 7,200 rpm 3.5-inch NL-SAS disks (6+2 RAID 6) The configuration assumes that each user has 10 GB of private storage space. 40

41 Installing and configuring the vsphere hosts This section provides information about installing and configuring the vsphere hosts and infrastructure servers required to support the architecture. Table 15 describes the tasks to be completed. Table 15. Tasks for server installation Task Description Reference Install vsphere Configure vsphere networking Add vsphere hosts to the XtremIO initiator groups Connect VMware datastores Optimize vsphere Install the vsphere hypervisor on the physical servers deployed for the solution. Configure vsphere networking including network interface card (NIC) trunking, VMkernel ports, and virtual machine port groups. Add the vsphere hosts to the initiator groups created in Preparing and configuring the storage array. Connect the VMware datastores to the vsphere hosts deployed for the solution. Perform the configuration changes needed to ensure optimal performance of the XtremIO array vsphere Installation and Setup Guide vsphere Networking Configuring vsphere networking EMC Online Support vsphere Storage Guide Connecting vsphere datastores EMC XtremIO Storage Array User Guide Optimizing vsphere for XtremIO Installing vsphere On initial power up of the servers being used for vsphere, confirm or enable the hardware-assisted CPU virtualization setting and the hardware-assisted MMU virtualization setting in the server s BIOS. If the servers are equipped with a RAID controller, EMC recommends that you configure mirroring on the local disks. Start up the vsphere installation media and install the hypervisor on each of the servers. vsphere hostnames, IP addresses, and a root password are required for installation. The Customer Configuration Worksheet provides appropriate values. Configuring vsphere networking The VMware vsphere Networking guide describes vsphere networking configuration, including load balancing, link aggregation, and failover options. Choose the appropriate load-balancing option based on what is supported by the network infrastructure. Refer to the list of documents in Reference Documentation for more information. Network interface cards During the installation of vsphere, a standard virtual switch (vswitch) is created. By default, vsphere chooses only one physical NIC as a vswitch uplink. To maintain 41

42 redundancy and bandwidth requirements, configure an additional NIC, either by using the vsphere console or by connecting to the vsphere host from the vsphere Client. Each vsphere server should have multiple interface cards for each virtual network to ensure redundancy and provide for the use of network load balancing, link aggregation, and network adapter failover. VMkernel ports Create the following VMkernel ports as required, based on the infrastructure configuration: VMkernel port for vmotion Virtual desktop port groups (used by the virtual desktops to communicate on the network) The VMware vsphere Networking guide describes the procedure for configuring these settings. Refer to the list of documents in Reference Documentation for more information. Connecting vsphere datastores Connect the data stores configured in Preparing and configuring the storage array to the appropriate vsphere servers. These include the datastores configured for: Virtual desktop storage Infrastructure virtual machine storage (if required) SQL Server storage (if required) To enable vsphere servers to access the XtremIO volumes, configure XtremIO initiator groups and add the appropriate vsphere hosts to each using the following steps in the XtremIO Storage Management Application: 1. Click Configuration. 2. In the Initiator Group pane, click Add. 3. In the Add New Initiator Group window, type a name in the Initiator Group Name field, and then click Add. 4. In the Add Initiator window, type a name in the Initiator Name field, and then use the Initiator Port Address list to select the initiator port of a vsphere server that should be in the target initiator group. Click Ok to return to the Add Initiator window 5. In the Add Initiator window, repeat step 4 as needed to add all target initiator ports to the initiator group. Once all initiators have been added, click Finish. 6. In the Configuration menu, select the target volumes from the Volumes pane, the target initiator group from the Initiator Groups pane, click the Map All button, and then click Apply to complete the process and grant the vsphere servers access to the selected volumes. Repeat as needed to grant the remaining initiator groups access to the remaining volumes. 7. Perform a Rescan for Datastores operation on the vsphere hosts so that they will immediately see the XtremIO volumes they were granted access to. 42

43 8. Repeat this process as needed, creating an initiator group for each vsphere cluster. The VMware vsphere Storage guide provides instructions on how to format the vsphere datastores when XtremIO initiator groups have been configured. Refer to the list of documents in Reference Documentation for more information. Optimizing vsphere for XtremIO Multiple changes are required to ensure optimal performance of the XtremIO array when used with vsphere. These changes are outlined in the EMC XtremIO Storage Array User Guide, and include: Change the vsphere storage device path selection setting to Round Robin (VMware) for each vsphere datastore. This can be done using the following vsphere PowerCLI command, replacing cluster with the name of the vsphere cluster where the target vsphere hosts reside. Repeat as needed for each cluster: Get-VMHost -location cluster get-scsilun -luntype "disk" where {$_.MultipathPolicy -ne "RoundRobin"} Set-ScsiLun - MultipathPolicy "RoundRobin" Change vsphere Disk.SchedQuantum setting to 64 and Disk.DiskMaxIOSize setting to This can be done using the following vsphere PowerCLI commands, replacing cluster with the name of the vsphere cluster where the target vsphere hosts reside. Repeat as needed for each cluster: Get-VMhost -location cluster Set- VMhostAdvancedConfiguration Disk.SchedQuantum -Value 64 Get-VMhost -location cluster Set- VMhostAdvancedConfiguration Disk.DiskMaxIOSize -Value 4096 Change the vsphere Disk.SchedNumReqOutstanding setting to 256 for each vsphere datastore. This can be done using the following vsphere PowerCLI script. Repeat as needed for each vsphere cluster, updating the script with the target ClusterName: $vmhosts = get-vmhost location ClusterName foreach ($vmhost in $vmhosts) { $esxcli = get-esxcli -vmhost $vmhost $AllLUNs = get-scsilun -vmhost $vmhost where {$_.vendor -eq "XtremIO"} foreach ($lun in $AllLUNs) { $CN = $lun.canonicalname $EsxCli.storage.core.device.set($null, $cn, $null, $null, $null, $null, $null, 256, $on) } } The settings described in this section apply only to vsphere hosts connected to EMC XtremIO arrays, and should not be applied to block datastores hosted on other arrays, including other EMC arrays. It is acceptable to use these settings on vsphere hosts that are connected to NFS datastores as well as an XtremIO, as the settings will have no effect on the communication with those NFS datastores. 43

44 Installing and configuring the SQL Server database Table 16 describes the tasks for setting up and configuring a Microsoft SQL Server database for the solution. When the tasks are complete, SQL Server is set up on a virtual machine, with all of the databases required by vcenter, Update Manager, XenDesktop, and Citrix Provisioning Services. Note: EMC recommends that you put the OS volume for the SQL Server virtual machine into the VSPEX private cloud pool. The recommended values for CPU and memory are listed in Table 16. Table 16. Tasks for SQL Server database setup Task Description Reference Create a virtual machine for SQL Server Install Microsoft Windows on the virtual machine Install SQL Server Configure the database for VMware vcenter Server Configure the database for VMware Update Manager Configure VMware vcenter database permissions Configure VMware Update Manager database permissions Create a virtual machine to host SQL Server on one of the vsphere servers designated for infrastructure virtual machines, and use the datastore designated for the shared infrastructure. Verify that the virtual server meets the hardware and software requirements. Install Microsoft Windows Server 2012 R2 Standard Edition on the virtual machine. Install SQL Server 2012 on the virtual machine. Create the database required for vcenter Server on the appropriate datastore. Create the database required for Update Manager on the appropriate datastore. Configure the database server with appropriate permissions for vcenter. Configure the database server with appropriate permissions for Update Manager. vsphere Virtual Machine Administration Install and Deploy Windows Server 2012 R2 SQL Server Installation (SQL Server 2012) Preparing vcenter Server Databases Preparing the Update Manager Database Preparing vcenter Server Databases Preparing the Update Manager Database 44

45 VMware vcenter Server deployment Table 17 describes the tasks to be completed to configure VMware vcenter Server for the solution. Note: EMC recommends that you put the OS volume for the vcenter Server virtual machine into the VSPEX private cloud pool. The recommended values for CPU and memory are listed in Table 12. Table 17. Tasks for vcenter configuration Task Description Reference Create the vcenter host virtual machine Install the vcenter guest OS Update the virtual machine Create vcenter ODBC connections Install vcenter Server Install vcenter Update Manager Create a virtual datacenter Apply vsphere license keys Add vsphere Hosts Configure vsphere clustering Install the vcenter Update Manager plug-in Deploy EMC PowerPath/VE Create a virtual machine for vcenter Server. Install Windows Server 2012 R2 Standard Edition on the vcenter host virtual machine. Install VMware Tools, enable hardware acceleration, and allow remote console access. Create the 64-bit vcenter and 32-bit vcenter Update Manager ODBC connections. Install the vcenter Server software. Install the vcenter Update Manager software. Create a virtual datacenter. Type the vsphere license keys in the vcenter licensing menu. Connect the vcenter server to the vsphere hosts. Create a vsphere cluster and move the vsphere hosts into it. Install the vcenter Update Manager plug-in from the administration console. Use Update Manager to deploy the PowerPath/VE plug-in to all vsphere hosts. vsphere Virtual Machine Administration VMware vsphere Documentation vsphere Virtual Machine Administration vsphere Installation and Setup Installing and Administering VMware vsphere Update Manager vsphere Installation and Setup Installing and Administering VMware vsphere Update Manager vcenter Server and Host Management vsphere Installation and Setup vcenter Server and Host Management vsphere Resource Management Installing and Administering VMware vsphere Update Manager EMC PowerPath/VE for VMware vsphere Installation and Administration Guide 45

46 Task Description Reference Install the EMC VSI for VMware vsphere plug-in Install EMC PowerPath Viewer Install the VSI for VMware vsphere plug-in on the administration console. Install PowerPath Viewer on the administration console. EMC VSI for VMware vsphere: Unified Storage Management Product Guide EMC PowerPath Viewer Installation and Administration Guide Installing and configuring XenDesktop Desktop Delivery Controllers This section provides information on how to set up and configure XenDesktop Delivery Controllers for the solution. For a new installation of XenDesktop, Citrix recommends that you complete the tasks in Table 18 in the order shown. Note: EMC recommends that you put the OS volume for the XenDesktop Desktop Delivery Controller virtual machines into the VSPEX private cloud pool. The recommended values for CPU and memory are listed in Table 12. Table 18. Tasks for XenDesktop controller setup Task Description Reference Creating virtual machines for XenDesktop Delivery Controllers Installing the guest operating system for the XenDesktop Delivery Controllers Installing the XenDesktop server-side components Installing Citrix Studio Configuring a site Adding a second XenDesktop Delivery Controller Create two virtual machines in vsphere Client. These virtual machines are used as XenDesktop Delivery Controllers. Install the Windows Server 2012 R2 or Windows Server 2012 guest operating system on the virtual machines. Install the required XenDesktop server components on the first Delivery Controller. Install Citrix Studio to manage XenDesktop deployment remotely. Configure a site in Citrix Studio. Install an additional Delivery Controller for high availability. vsphere Virtual Machine Administration Citrix website 46

47 Task Description Reference Preparing a master virtual machine Provisioning the virtual desktops Create a master virtual machine as the base image for the virtual desktops. Provision the virtual desktops using MCS. Installing serverside components of XenDesktop Install the following XenDesktop server-side components on the first Delivery Controller: Delivery Controller: Distributes applications and desktops, manages user access, and optimizes connections Citrix Studio: Creates, configures and manages infrastructure components, applications, and desktops Citrix Director: Monitors performance and troubleshoots problems License server: Manages product licenses Citrix StoreFront: Provides authentication and resource delivery services for Citrix Receiver Note: Citrix supports installation of XenDesktop components only through the procedures described in Citrix documentation. Configuring a site Adding a second controller Start Citrix Studio and configure a site as follows: 1. License the site and specify which edition of XenDesktop to use. 2. Set up the site database using a designated login credential for SQL Server. 3. Provide information about your virtual infrastructure, including the vcenter SDK path that the controller will use to establish a connection to the VMware infrastructure. After you have configured a site, you can add a second Delivery Controller to provide high availability. The XenDesktop server-side components required for the second controller are: Delivery Controller Citrix Studio Citrix Director Citrix StoreFront Do not install the license-server component on the second controller because it is centrally managed on the first controller. Installing Citrix Studio Install Citrix Studio on the appropriate administrator consoles to manage your XenDesktop deployment remotely. 47

48 Preparing the master virtual machine Provisioning the virtual desktops Complete the following steps to prepare the master virtual machine: 1. Install the Windows 8.1 guest OS. 2. Install the appropriate integration tools such as VMware Tools. 3. Optimize the OS settings to prevent unnecessary background services from generating non-essential I/O operations that adversely affect the overall performance of the storage array. Refer to the following White Paper for details: Citrix Windows 8.1 Optimization Guide for Desktop Virtualization. 4. Install the Virtual Delivery Agent. 5. Install the third-party tools or applications, such as Microsoft Office, relevant to your environment. 6. Install the Avamar Desktop/Laptop Client. Complete the following steps in Citrix Studio to deploy MCS-based virtual desktops: 1. Create a machine catalog using the master virtual machine as the base image. MCS allows the creation of a machine catalog that contains various types of desktops. We tested the following desktop types for this solution: Windows Desktop OS: Random: Users connect to a new (random) desktop each time they log on. PvD: Users connect to the same (static) desktop each time they log on. Changes are saved on a separate PvD. Windows Server OS: Provides hosted shared desktops for deployment of standardized machines 2. Add the machines created in the catalog to a delivery group so that the virtual desktops are available to the end users. 48

49 Installing and configuring Citrix Provisioning Services This section provides information about how to set up and configure Citrix PVS for the solution. For a new installation of PVS, Citrix recommends that you complete the tasks in Table 19 in the order shown. Table 19. Tasks for XenDesktop controller setup Task Description Reference Creating virtual machines for PVS servers Installing the guest operating system for the PVS servers. Installing the PVS server-side components Configuring a PVS server farm Adding a second PVS server Creating a PVS store Configuring inbound communication Configuring a bootstrap file Configuring boot options 66 and 67 on the DHCP server Preparing a master virtual machine Provisioning the virtual desktops Create two virtual machines in vsphere Client. These virtual machines are used as PVS servers. Install the Windows Server 2012 R2 or Windows Server 2012 guest operating system for the PVS servers. Install the PVS server components and console on the PVS server. Run the Provisioning Services Configuration Wizard to create a PVS server farm. Install the PVS server components and console on the second server and join it to the existing server farm. Specify the store path where the vdisks will reside. Adjust the total number of threads to be used to communicate with each virtual desktop. Update the bootstrap image to use both PVS servers to provide streaming services. Specify the TFTP server IP and the name of the bootstrap image used for the Preboot execution Environment (PXE) boot. Create a master virtual machine as the base image for the virtual desktops. Provision the virtual desktops using PVS. vsphere Virtual Machine Administration Citrix website 49

50 Configuring a PVS server farm Adding a second PVS server Creating a PVS store Configuring inbound communication After the PVS server components are installed on the PVS server, start the Provisioning Services Configuration Wizard and configure a new server farm using the following options: 1. Specify the DHCP service to be run on another computer. 2. Specify the PXE service to be run on this computer. 3. Select Create farm to create a new PVS server farm using a designated SQL Server database instance. 4. When creating a new server farm, you need to create a site. Provide an appropriate name for the new site and target device collection. 5. Select the license server that is running on the XenDesktop controller. 6. Select Use the Provisioning Services TFTP service. After you have configured a PVS server farm, you can add a second PVS server to provide high availability. Install the PVS server components and console on the second PVS server and run the Provisioning Services Configuration Wizard to join the second server to the existing server farm. A PVS store is a logical container for vdisks. When deploying PVS servers on datastores located on an XtremIO array, the PVS stores should be configured using virtual hard disks assigned to each PVS server. Each PVS server maintains a range of User Datagram Protocol (UDP) ports to manage all inbound communications from virtual desktops. Ideally, there should be one thread dedicated to each desktop session. The total number of threads supported by a PVS server is calculated as: Total threads = (Number of UDP ports * Threads per port * Number of network adapters) Adjust the thread count accordingly to match the number of deployed virtual desktops. Configuring a bootstrap file To update the bootstrap file required for the virtual desktops to PXE boot, complete the following steps: 1. In the Provisioning Services console, select Farm > Sites > Site-name > Servers. 2. Right-click a server and select Configure Bootstrap. The Configure Bootstrap dialog box appears, as shown in Figure

51 Figure 12. Configure Bootstrap dialog box 3. Update the bootstrap image to reflect the IP addresses used for all PVS servers that provide streaming services in a round-robin fashion. Select Read Servers from Database to obtain a list of PVS servers automatically or select Add to manually add the server information. 4. After modifying the configuration, click OK to update the ARDBP32.BIN bootstrap file, which is located at C:\ProgramData\Citrix\Provisioning Services\Tftpboot. 5. Navigate to the folder and examine the timestamp of the bootstrap file to ensure that it is updated on the intended PVS server. Configuring boot options 66 and 67 on DHCP server To PXE boot the virtual desktops successfully from the bootstrap image supplied by the PVS servers, set the boot options 66 and 67 on the Microsoft DHCP server. Complete the following steps to configure the boot options on the DHCP server: 1. From the DHCP management interface of the DHCP server, right-click Scope Options and select Configure Options. 2. Select 066 Boot Server Host Name. In String value, type the IP address of the PVS server configured as the TFTP server. 3. Select 067 Bootfile Name. In String value, type ARDBP32.BIN. The ARDBP32.BIN bootstrap image is loaded on a virtual desktop before the vdisk image is streamed from the PVS servers. 51

52 Preparing the master virtual machine Provisioning the virtual desktops Complete the following steps to prepare the master virtual machine: 1. Install the Windows 8.1 guest OS. 2. Install appropriate integration tools such as VMware Tools. 3. Optimize the OS settings to prevent unnecessary background services from generating inessential I/O operations that adversely affect the overall performance of the storage array. Refer to the following White Paper for details: Citrix Windows 8.1 Optimization Guide for Desktop Virtualization. 4. Install the Virtual Delivery Agent. 5. Install the third-party tools or applications, such as Microsoft Office, relevant to your environment. 6. Install the PVS target device software on the master virtual machine. 7. Modify the BIOS of the master virtual machine so that the network adapter is at the top of the boot order to ensure PXE boot of the PVS bootstrap image. Complete the following steps to deploy the PVS-based virtual desktops: 1. Run the PVS imaging wizard to clone the master image onto a vdisk. 2. When the cloning is complete, shut down the master virtual machine and modify the following vdisk properties: Access mode: Standard Image Cache type: Cache on device hard drive 3. Prepare a virtual machine template to be used by the XenDesktop Setup Wizard in the next step. 4. Run the XenDesktop Setup Wizard in the PVS console to create a machine catalog that contains the specified number of virtual desktops. 5. Add the virtual desktops created in the catalog to a delivery group so that the virtual desktops are available to the end users. Setting up EMC Avamar Avamar configuration overview This section provides information about installing and configuring Avamar to support guest-based backups of user files. There are other Avamar-based methods for backing up user files; however, guest-based backups provide end-user restore capabilities using a common GUI. For this configuration, it is assumed that only a user s files and profile are being backed up. Table 20 describes the tasks that must be completed. Note: In addition to the backups produced by the procedure described here, you should regularly back up the data center infrastructure components required by XenDesktop virtual desktops. A full disaster recovery requires the ability to restore XenDesktop enduser computing in combination with the ability to restore XenDesktop virtual desktop user data and files. 52

53 Table 20. Tasks for Avamar integration Task Description Reference Microsoft Active Directory preparation Configuring Group Policy Object (GPO) additions for Avamar Create and configure a GPO to enable Avamar backups of user files and profiles. EMC Avamar 7 Administrator Guide Citrix XenDesktop master (gold) image preparation Preparing the master image for Avamar Install and configure the Avamar Client to run in user mode. Installing and configuring XenDesktop Desktop Delivery Controllers Preparing the master virtual machine Avamar preparation Defining Avamar datasets Defining Avamar backup schedules Adjusting the maintenance window schedule Defining Avamar retention policies Creating an Avamar Group and Group Policy Create and configure Avamar datasets to support user files and profiles. Create and configure an Avamar backup schedule to support virtual desktop backups. Modify the maintenance window schedule to support virtual desktop backups. Create and configure Avamar retention policy. Create and configure Avamar Group and Group Policy. EMC Avamar 7 Administrator Guide EMC Avamar 7 Operational Best Practices Post-desktop deployment Activating XenDesktop clients (desktops) Activate XenDesktop virtual desktops using Avamar Enterprise Manager. EMC Avamar 7 Administrator Guide 53

54 Configuring Group Policy object (GPO) additions for Avamar Because of current Avamar limitations (no support for client-side variables, for example, %username%) and to reduce the management burden, you must use mapped drives for user data and user profiles. To create the mapped drives and to configure Windows Folder Redirection to create the Universal Naming Convention (UNC) paths needed for the drives, create and edit a new GPO in the Group Policy Management Editor, as described in the following procedures. Folder redirection To configure Windows folder redirection: 1. Navigate to the User Configuration > Policies > Windows Settings > Folder Redirection policy setting. 2. Right-click Documents. 3. Select Properties. 4. From the Settings list box, select Basic Redirect everyone s folder to the same location. 5. Type \\CIFS_server\folder, as shown in Figure 13. Figure 13. Configuring Windows Folder Redirection 54

55 Mapped drives Chapter 4: Solution Implementation Create two mapped drive configurations, one for user files and one for user profiles. Follow the same procedure for each mapped drive but use different values for Location, Label As, and Drive Letter Used. To configure drive mappings: 1. Navigate to the User Configuration > Preferences > Windows Settings > Drive Maps policy setting. 2. Right-click the blank (white) area on the right side of the window. 3. Select New > Mapped Drive, as shown in Figure 14. The Mapped Drive Properties window appears. Figure 14. Opening the Mapped Drive Properties dialog box 4. To create the user files mapped drive, follow these steps, as shown in Figure 15: a. From the Action list, select Create. b. In Location, type \\cifs_server\folder\%username%. c. Select Reconnect. d. In Label as, type User_Files. e. In Drive Letter, select Use: and U. f. In Hide/Show this drive, select Hide this drive. 55

56 Figure 15. Creating a Windows network drive mapping for user files 5. In the New Drive Properties window, click Common and select Run in loggedon user s security context (user policy option), as shown in Figure

57 Figure 16. Configuring drive mapping common settings 6. Click Apply. 7. To create the user profiles mapped drive: a. Repeat the steps for creating the user files mapped drive, but change the following three variables as specified (Figure 17 shows a sample configuration): In Location, type \\cifs_server\folder\%username%.domain.v2, where domain is the Active Directory domain name. In Label as, type User_Profile. In Drive Letter, select Use: and P. 57

58 Figure 17. Creating a Windows network drive mapping for user profile data 8. Click OK. 9. Close the Group Policy Management Editor. Windows security for Avamar client service This section provides information about using the Avamar Client for Windows to provide data protection for XenDesktop virtual desktops that store user-generated files in VNX home directories. The Avamar Client for Windows installs and runs a Windows service named Backup Agent. This service provides backup and restore functions. Windows security limits the access of services logged on using the Local System account to local resources only. In its default configuration, the Backup Agent uses the Local System account to log on. It cannot access network resources, including the XenDesktop user profile or data file shares. To access XenDesktop user profile and data file shares, the Backup Agent must run as the currently logged on user. A batch file starts Backup Agent and logs it on as a user when the user logs in. 58

59 Defining Avamar datasets The next several sections assume that the Avamar Grid is up and functional and that you have logged into Avamar Administrator. For information on accessing Avamar Administrator, refer to EMC Avamar 7 Administration Guide. An Avamar dataset consists of lists of directories and files to backup from a client. Assigning a dataset to a client or group enables you to save backup selections. For additional information about datasets, refer to EMC Avamar 7 Administration Guide. This section provides dataset configuration information, specific to XenDesktop virtual desktops, which is required to ensure successful backups of user files and user profiles. Create two datasets, one for user files and one for user profiles. Follow the same procedure for each dataset but use different values for Name and Drive Letter Used. There are also additional steps for creating the user profiles dataset. 1. In the Avamar Administrator window, shown in Figure 18, click Tools and select Manage Datasets. Figure 18. Configuring Windows Folder Redirection 2. In the Manage All Datasets window, click New. 3. In the New Dataset window, select the custom settings shown in Figure

60 Figure 19. Configuring Avamar dataset settings a. Remove all other plug-ins from the list by selecting each one and clicking Remove ( ) b. In Name, type View-User-Files. c. Select Enter Explicitly. d. From the Select Plug-in Type list box, select Windows File System. e. In Select Files and/or Folders, type U:\, and then click Add (+). 4. Click OK to save the dataset. 5. Repeat steps 1 to 4 using the following values to create a new dataset for user profile data: In Name, type View-User-Profile. In Select Files and/or Folders, type P:\. Additional configurations are required to back up User Profile data; Figure 20 shows a sample configuration. 6. Click Exclusions. 7. From the Select Plug-in Type list box, select Windows File System. 8. In Select Files and/or Folders, type P:\avs and click Add (+). Figure 20. User profile dataset Exclusion settings 60

61 9. Click Options as shown in Figure 21. Figure 21. Select Plug-in Type option 10. From the Select Plug-in Type list box, select Windows File System. 11. Select Show Advanced Options. 12. Scroll down the list of options and select Volume Freezing Options as shown in Figure 22. Figure 22. Volume Freezing Options 13. From the Method to freeze volumes list box, select None. 14. Click OK to save the dataset. 61

62 Defining Avamar backup schedules Adjusting the maintenance window schedule Avamar schedules are reusable objects that control when group backups and custom notifications occur. Define a reoccurring schedule that satisfies your recovery point objectives (RPO). For additional information about datasets, refer to the EMC Avamar7 Administration Guide. Avamar server maintenance includes the following essential activities: Checkpoint: A snapshot of the Avamar server specifically taken to facilitate server rollbacks. Checkpoint validation: An internal operation that validates the integrity of a specific checkpoint. Once a checkpoint passes validation, it can be considered reliable enough to be used for a server rollback. Garbage collection: An internal operation that recovers storage space from deleted or expired backups. Each 24-hour day is divided into three operational windows, during which various system activities are performed: Backup window: That portion of each day reserved to perform normal scheduled backups. No maintenance activities are performed during the backup window. Blackout window: That portion of each day reserved to perform server maintenance activities, primarily garbage collection, that require unrestricted access to the server. No backup or administrative activities are allowed during the blackout window. However, you can perform restores. Maintenance window: That portion of each day reserved to perform routine server maintenance activities, primarily checkpoint creation and validation. Figure 23 shows the default Avamar backup, blackout, and maintenance windows. Figure 23. Avamar default Backup/Maintenance Windows schedule 62

63 User files and profile data should not be backed up during the day while the users are logged onto their virtual desktops. Adjust the backup window start time to prevent backups from occurring during that time. Figure 24 shows a modified backup, blackout, and maintenance window for backing up Citrix XenDesktop virtual desktops. Figure 24. Avamar modified Backup/Maintenance Windows schedule To adjust the schedule to appear as shown above, change the Backup Window Start Time from 8:00 PM to 8:00 AM, and click OK to save the changes. For additional information about Avamar server maintenance activities, refer to the EMC Avamar 7 Administration Guide. Defining Avamar retention policies Avamar backup retention policies enable you to specify how long to keep a backup in the system. A retention policy is assigned to each backup when the backup occurs. Specify a custom retention policy to perform an on-demand backup, or create a retention policy that is assigned automatically to a group of clients during a scheduled backup. When the retention for a backup expires, the backup is automatically marked for deletion. The deletion occurs in batches during times of low system activity. For additional information on defining retention policies, refer to the EMC Avamar 7 Administration Guide. Creating an Avamar Group and Group Policy Avamar uses groups to implement various policies to automate backups and enforce consistent rules and system behavior across an entire segment, or group, of the user community. Group members are client machines that have been added to a particular group to perform scheduled backups. 63

64 In addition to specifying which clients belong to a group, groups also specify: Datasets Schedules Retention polices These objects make up the group policy, which controls backup behavior for all members of the group unless you override these settings at the client level. For additional information about groups and group policies, refer to the EMC Avamar 7 Administration Guide. This section provides group configuration information that is required to ensure proper backups of user files and user profiles. Create two groups and their respective group policy, one for user files and one for user profiles. Follow the same procedure for each group but use different values for Name and Dataset Used: 1. In Avamar Administrator, select Actions > New Group, as shown in Figure 25. Figure 25. Creating a new Avamar backup group The New Group window appears. 2. In Name, type View_User_Data as shown in Figure 26. Figure 26. New Group window 64

65 3. Ensure that Disabled is cleared. 4. Click Next. Chapter 4: Solution Implementation 5. From the Select An Existing Dataset list box, select Citrix Xendesktop-User- Data. 6. Click Next. 7. From the Select An Existing Schedule list box, select a schedule, and then click Next, as shown in Figure 27. Figure 27. Select An Existing Schedule 8. From the Select An Existing Retention Policy list, select a retention policy. 9. Click Finish. Note: If you select Next instead of Finish, you can select the clients to be added to the group. However, this step is unnecessary, because clients will be added to the group during activation. Activating XenDesktop clients (desktops) Avamar Enterprise Manager is a web-based multisystem management console application that provides centralized Avamar system administration capabilities, including the ability to add and activate Avamar Clients all at once. In this section, we assume that you know how to log into Avamar Enterprise Manager (EM), and that the XenDesktop desktops are created. 65

66 After you log in to Avamar EM, the Enterprise Manager Dashboard appears, as shown in Figure 28. Figure 28. Avamar Enterprise Manager Dashboard 1. Click Client Manager. 2. In the Avamar Client Manager window, click Activate as shown in Figure 29. Figure 29. Avamar Client Manager 3. In the Activate window, click the Client Information list arrow and select Directory Service, as shown in Figure

67 Figure 30. Client Information menu The Directory Service dialog box appears. 4. Type the required user credentials, as shown in Figure 31: Figure 31. Directory Service dialog box This assumes an Active Directory service has been configured in Avamar, refer to the EMC Avamar 7.0 Administration Guide for additional information about enabling LDAP Management. a. In the User Domain list, select a directory service domain. b. In User Name and Password, type the user name and password required for directory service authentication. c. In Directory Domain, select a directory domain to query for client information, and then click OK. The Active Directory information appears in the Client Information pane of the EMC Avamar Client Manager window, as shown in Figure

68 Figure 32. EMC Avamar Client Manager with Active Directory information 5. In the Client Information directory tree, locate the Citrix XenDesktop virtual desktops. In this example, an OU was created named VSPEX, as shown in Figure 33. Figure 33. VSPEX virtual desktops 6. Select the virtual machine desktops you want to add to the Avamar server, as shown in Figure

69 Figure 34. Selected virtual desktops 7. Drag and drop the selected list to the existing Avamar Domain in the Server Information pane. The Select Groups window appears as shown in Figure 35. Figure 35. Select Groups window 8. Under Group Name, select the groups to which you want to add these desktops, and then click Add. The EMC Avamar Client Manager window reappears. 9. Select the Avamar domain to which you just added the virtual desktops, and then click Activate, as shown in Figure

70 Figure 36. Activate domain The Show Clients for Activation window appears. 10. Click Commit, as shown in Figure 37. Figure 37. Show Clients for Activation window An Alert appears, indicating that the client activation will be performed as a background process. 11. Click OK. A second Alert indicates that the activation process has been initiated and that you should check the logs for status. 12. Click OK. 70

71 The Avamar Client Manager window reappears with the activated clients listed, as shown in Figure 38. Figure 38. Avamar Client Manager with activated clients 13. Log out from Avamar Enterprise Manager. 71

72 72

73 Chapter 5: Solution Verification Chapter 5 Solution Verification This chapter presents the following topics: Overview Post-installation checklist Deploy and test a single virtual desktop Verify the redundancy of the solution components

74 Chapter 5: Solution Verification Overview After you configure the solution, complete the tasks in Table 21 to verify the configuration and functionality of specific aspects of the solution, and ensure that the configuration supports core availability requirements. Table 21. Tasks for testing the installation Task Description Reference Verify installation with post installation checklist Deploy and test a single virtual desktop Verify redundancy of the solution components Provision remaining virtual desktops Verify that adequate virtual ports exist on each vsphere host virtual switch. Verify that each vsphere host has access to the required datastores and VLANs. Verify that the vmotion interfaces are configured correctly on all vsphere hosts. Deploy a single virtual machine from the vsphere interface by using the customization specification. Restart each storage processor in turn and ensure that connectivity to the VMware datastores is maintained. Disable each of the redundant switches in turn and verify that the vsphere host, virtual machine, and storage array connectivity remains intact. On a vsphere host that contains at least one virtual machine, enable maintenance mode and verify that the virtual machine can successfully migrate to an alternate host. Provision desktops using MCS or PVS. vsphere Networking vsphere Storage Guide vsphere Networking vsphere Networking vcenter Server and Host Management vsphere Virtual Machine Management Verify the redundancy of the solution components Vendor documentation vcenter Server and Host Management Installing and configuring XenDesktop Desktop Delivery Controllers Installing and configuring Citrix Provisioning Services 74

75 Chapter 5: Solution Verification Post-installation checklist The following configuration tasks are critical to the functionality of the solution. Verify these before deploying the solution into production. On each vsphere server used as part of this solution, verify the following: The vswitches hosting the client VLANs are configured with sufficient ports to accommodate the maximum number of virtual machines a host can accommodate. All the required virtual machine port groups are configured and each server has access to the required VMware datastores. An interface is configured correctly for vmotion. Refer to the vsphere Networking guide for details. Refer to the list of documents in Chapter 6 for more information. Deploy and test a single virtual desktop Deploy a single virtual machine to verify the operation of the solution. Ensure the virtual machine has been joined to the applicable domain, has access to the expected networks, and that it is possible to log in. Verify the redundancy of the solution components To ensure that the various components of the solution maintain availability requirements, you can test the specific scenarios related to maintenance or hardware failure with the following important steps: 1. Restart each XtremIO storage controller in turn and verify that connections to the VMFS datastores are maintained. Complete the following steps: a. Log into the storage controller A using the xinstall account. b. Restart the controller using option 6 in the install menu. c. During the restart cycle, check for the presence of VMFS datastores on the vsphere hosts. d. Using the XtremIO Storage Management Application interface, verify that storage controller A comes back online by monitoring the Alerts window or the Hardware tab. e. Repeat the procedure for storage controller B. 2. Restart each VNX storage processor in turn and verify that the connections to the CIFS file systems are maintained. Complete the following steps: a. Log into the control station with administrator privileges. b. Navigate to /nas/sbin. c. Restart SPA: use the command./navicli -h spa rebootsp. 75

76 Chapter 5: Solution Verification d. During the restart cycle, check for the presence of datastores on vsphere hosts. e. When the cycle completes, restart SPB:./navicli -h spb rebootsp. 3. Perform a failover of each VNX Data Mover in turn and verify that connections to the CIFS file systems are re-established. Use the following approach for each Data Mover; use the Unisphere interface to restart. a. From the control station $ prompt, run the command server_cpu movername -reboot, where movername is the name of the Data Mover. b. To verify that network redundancy features function as expected, disable each of the redundant switching infrastructures in turn. While each of the switching infrastructures is disabled, verify that all the components of the solution maintain connectivity to each other and to any existing client infrastructure as well. 4. On a vsphere host that contains at least one virtual machine, enable maintenance mode and verify that the virtual machine can migrate to an alternate host. 76

77 Chapter 6: Reference Documentation Chapter 6 Reference Documentation This chapter presents the following topics: EMC documentation Other documentation

78 Chapter 6: Reference Documentation EMC documentation Other documentation The following documents, located on EMC Online Support provide additional and relevant information. Access to these documents depends on your login credentials. If you do not have access to a document, contact your EMC representative. EMC XtremIO Storage Array User Guide EMC XtremIO Storage Array Operations Guide EMC XtremIO Storage Array Software Installation and Upgrade Guide EMC XtremIO Storage Array Hardware Installation and Upgrade Guide EMC XtremIO Storage Array Security Configuration Guide EMC XtremIO Storage Array Pre-Installation Checklist EMC XtremIO Storage Array Site Preparation Guide EMC VNX5400 Unified Installation Guide EMC VSI for VMware vsphere: Storage Viewer Product Guide EMC VSI for VMware vsphere: Unified Storage Management Product Guide VNX Installation Assistant for File/Unified Worksheet VNX FAST Cache: A Detailed Review White Paper Deploying Microsoft Windows 8 Virtual Desktops Applied Best Practices White Paper EMC PowerPath/VE for VMware vsphere Installation and Administration Guide EMC PowerPath Viewer Installation and Administration Guide EMC VNX Unified Best Practices for Performance Applied Best Practices White Paper The following documents, available on the VMware website, provide additional and relevant information: VMware vsphere Installation and Setup Guide VMware vsphere Networking VMware vsphere Resource Management VMware vsphere Storage Guide VMware vsphere Virtual Machine Administration VMware vsphere Virtual Machine Management VMware vcenter Server and Host Management Installing and Administering VMware vsphere Update Manager Preparing the Update Manager Database 78

79 Preparing vcenter Server Databases Chapter 6: Reference Documentation Understanding Memory Resource Management in VMware vsphere 5.0 The following documents, available on the Citrix website, provide additional and relevant information: Definitive Guide to XenApp 7.5 and XenDesktop 7.5 Windows 7 Optimization Guide for Desktop Virtualization Windows 8 and 8.1 Virtual Desktop Optimization Guide The following documents, available on the Microsoft website, provide additional and relevant information: Installing Windows Server 2012 R2 SQL Server Installation (SQL Server 2012) 79

80 Chapter 6: Reference Documentation 80

81 Appendix A: Configuration Worksheet Appendix A Configuration Worksheet This appendix presents the following topic: Customer Configuration Worksheet

82 Appendix A: Configuration Worksheet Customer Configuration Worksheet Before configuring the solution, you need to gather some customer-specific configuration information such as IP addresses, hostnames, and so on. Table 22 to Table 28 provide a worksheet that you can use to record the information. You can also print and use the worksheet as a customer leave behind document for future reference. A standalone copy of the worksheet is attached to this document in Microsoft Office Word format. To view and print the worksheet: 1. In Adobe Reader, open the Attachments panel, as follows: Select View > Show/Hide > Navigation Panes > Attachments. or Click the Attachments icon, as shown in Figure 39. Figure 39. Opening attachments in a PDF file 2. Under Attachments, double-click the attached file to open and print the worksheet. To confirm the customer information, cross-reference with the relevant array configuration worksheet: VNX Installation Assistant for File/Unified Worksheet. 82

EMC VSPEX END-USER COMPUTING Citrix XenDesktop 7.6 and VMware vsphere with EMC XtremIO

EMC VSPEX END-USER COMPUTING Citrix XenDesktop 7.6 and VMware vsphere with EMC XtremIO IMPLEMENTATION GUIDE EMC VSPEX END-USER COMPUTING Citrix XenDesktop 7.6 and VMware vsphere with EMC XtremIO Enabled by EMC Isilon, EMC VNX, and EMC Data Protection EMC VSPEX Abstract This describes the

More information

EMC VSPEX END-USER COMPUTING

EMC VSPEX END-USER COMPUTING IMPLEMENTATION GUIDE EMC VSPEX END-USER COMPUTING Citrix XenDesktop 7.1 and VMware vsphere for up to 500 Virtual Desktops Enabled by EMC VNXe3200 and EMC Powered Backup EMC VSPEX Abstract This describes

More information

EMC VSPEX END-USER COMPUTING

EMC VSPEX END-USER COMPUTING IMPLEMENTATION GUIDE EMC VSPEX END-USER COMPUTING Citrix XenDesktop 7 and Microsoft Hyper-V for up to 2,000 Virtual Desktops Enabled by EMC Next-Generation VNX and EMC Powered Backup EMC VSPEX Abstract

More information

EMC VSPEX END-USER COMPUTING

EMC VSPEX END-USER COMPUTING IMPLEMENTATION GUIDE EMC VSPEX END-USER COMPUTING VMware Horizon View 5.3 and VMware vsphere for up to 2,000 Virtual Desktops Enabled by EMC Next-Generation VNX and EMC Powered Backup EMC VSPEX Abstract

More information

EMC VSPEX END-USER COMPUTING

EMC VSPEX END-USER COMPUTING IMPLEMENTATION GUIDE EMC VSPEX END-USER COMPUTING VMware Horizon View 6.0 and VMware vsphere for up to 500 Virtual Desktops Enabled by EMC VNXe3200 and EMC Data Protection EMC VSPEX Abstract This describes

More information

EMC VSPEX FOR VIRTUALIZED MICROSOFT EXCHANGE 2013 WITH MICROSOFT HYPER-V

EMC VSPEX FOR VIRTUALIZED MICROSOFT EXCHANGE 2013 WITH MICROSOFT HYPER-V IMPLEMENTATION GUIDE EMC VSPEX FOR VIRTUALIZED MICROSOFT EXCHANGE 2013 WITH MICROSOFT HYPER-V EMC VSPEX Abstract This describes the steps required to deploy a Microsoft Exchange Server 2013 solution on

More information

EMC VSPEX END-USER COMPUTING

EMC VSPEX END-USER COMPUTING DESIGN GUIDE EMC VSPEX END-USER COMPUTING Citrix XenDesktop 7 and VMware vsphere Enabled by EMC Next-Generation VNX and EMC Powered Backup EMC VSPEX Abstract This describes how to design an EMC VSPEX end-user

More information

EMC VSPEX END-USER COMPUTING

EMC VSPEX END-USER COMPUTING DESIGN GUIDE EMC VSPEX END-USER COMPUTING Citrix XenDesktop 7.1 and VMware vsphere for up to 500 Virtual Desktops Enabled by EMC VNXe3200 and EMC Powered Backup EMC VSPEX Abstract This describes how to

More information

EMC VSPEX END-USER COMPUTING

EMC VSPEX END-USER COMPUTING DESIGN GUIDE EMC VSPEX END-USER COMPUTING Citrix XenDesktop 7.5 and VMware vsphere Enabled by EMC VNX and EMC Data Protection EMC VSPEX Abstract This describes how to design an EMC VSPEX End-User Computing

More information

EMC VSPEX END-USER COMPUTING

EMC VSPEX END-USER COMPUTING DESIGN GUIDE EMC VSPEX END-USER COMPUTING Citrix XenDesktop 7.1 and Microsoft Hyper-V Enabled by EMC VNXe3200 and EMC Powered Backup EMC VSPEX Abstract This describes how to design an EMC VSPEX end-user

More information

EMC VSPEX END-USER COMPUTING

EMC VSPEX END-USER COMPUTING DESIGN GUIDE EMC VSPEX END-USER COMPUTING Citrix XenDesktop 7 and Microsoft Hyper-V Enabled by EMC Next-Generation VNX and EMC Powered Backup EMC VSPEX Abstract This describes how to design an EMC VSPEX

More information

EMC VSPEX END-USER COMPUTING

EMC VSPEX END-USER COMPUTING EMC VSPEX END-USER COMPUTING Citrix XenDesktop EMC VSPEX Abstract This describes how to design an EMC VSPEX end-user computing solution for Citrix XenDesktop using EMC ScaleIO and VMware vsphere to provide

More information

EMC VSPEX FOR VIRTUALIZED MICROSOFT EXCHANGE 2013 WITH HYPER-V

EMC VSPEX FOR VIRTUALIZED MICROSOFT EXCHANGE 2013 WITH HYPER-V IMPLEMENTATION GUIDE EMC VSPEX FOR VIRTUALIZED MICROSOFT EXCHANGE 2013 WITH HYPER-V EMC VSPEX Abstract This describes, at a high level, the steps required to deploy a Microsoft Exchange 2013 organization

More information

EMC VSPEX FOR VIRTUALIZED MICROSOFT SQL SERVER 2012 WITH MICROSOFT HYPER-V

EMC VSPEX FOR VIRTUALIZED MICROSOFT SQL SERVER 2012 WITH MICROSOFT HYPER-V IMPLEMENTATION GUIDE EMC VSPEX FOR VIRTUALIZED MICROSOFT SQL SERVER 2012 WITH MICROSOFT HYPER-V EMC VSPEX Abstract This describes, at a high level, the steps required to deploy multiple Microsoft SQL Server

More information

EMC VSPEX END-USER COMPUTING

EMC VSPEX END-USER COMPUTING VSPEX Proven Infrastructure EMC VSPEX END-USER COMPUTING Citrix XenDesktop 5.6 with VMware vsphere 5.1 for up to 250 Virtual Desktops Enabled by EMC VNXe and EMC Next-Generation Backup EMC VSPEX Abstract

More information

EMC VSPEX END-USER COMPUTING

EMC VSPEX END-USER COMPUTING DESIGN GUIDE EMC VSPEX END-USER COMPUTING VMware Horizon View 6.0 and VMware vsphere for up to 500 Virtual Desktops Enabled by EMC VNXe3200 and EMC Data Protection EMC VSPEX Abstract This describes how

More information

EMC VSPEX with Brocade Networking Solutions for END-USER COMPUTING

EMC VSPEX with Brocade Networking Solutions for END-USER COMPUTING VSPEX Proven Infrastructure EMC VSPEX with Brocade Networking Solutions for END-USER COMPUTING VMware View 5.1 and VMware vsphere 5.1 for up to 2000 Virtual Desktops Enabled by Brocade Network Fabrics,

More information

EMC INFRASTRUCTURE FOR VIRTUAL DESKTOPS ENABLED BY EMC VNX SERIES (NFS),VMWARE vsphere 4.1, VMWARE VIEW 4.6, AND VMWARE VIEW COMPOSER 2.

EMC INFRASTRUCTURE FOR VIRTUAL DESKTOPS ENABLED BY EMC VNX SERIES (NFS),VMWARE vsphere 4.1, VMWARE VIEW 4.6, AND VMWARE VIEW COMPOSER 2. EMC INFRASTRUCTURE FOR VIRTUAL DESKTOPS ENABLED BY EMC VNX SERIES (NFS),VMWARE vsphere 4.1, VMWARE VIEW 4.6, AND VMWARE VIEW COMPOSER 2.6 Reference Architecture EMC SOLUTIONS GROUP August 2011 Copyright

More information

EMC VSPEX END-USER COMPUTING

EMC VSPEX END-USER COMPUTING DESIGN GUIDE EMC VSPEX END-USER COMPUTING VMware Horizon View 5.3 and VMware vsphere for up to 2,000 Virtual Desktops Enabled by EMC Next-Generation VNX and EMC Powered Backup EMC VSPEX Abstract This describes

More information

Securing VSPEX VMware View 5.1 End- User Computing Solutions with RSA

Securing VSPEX VMware View 5.1 End- User Computing Solutions with RSA Design Guide Securing VSPEX VMware View 5.1 End- User Computing Solutions with RSA VMware vsphere 5.1 for up to 2000 Virtual Desktops EMC VSPEX Abstract This guide describes required components and a configuration

More information

EMC VSPEX END-USER COMPUTING

EMC VSPEX END-USER COMPUTING EMC VSPEX END-USER COMPUTING VMware Horizon View 5.2 and VMware vsphere 5.1 for up to 250 Virtual Desktops Enabled by EMC VNXe and EMC Next-Generation Backup EMC VSPEX Abstract This guide describes the

More information

EMC VSPEX FOR VIRTUALIZED MICROSOFT EXCHANGE 2013 WITH MICROSOFT HYPER-V

EMC VSPEX FOR VIRTUALIZED MICROSOFT EXCHANGE 2013 WITH MICROSOFT HYPER-V IMPLEMENTATION GUIDE EMC VSPEX FOR VIRTUALIZED MICROSOFT EXCHANGE 2013 WITH MICROSOFT HYPER-V EMC VSPEX Abstract This describes, at a high level, the steps required to deploy a Microsoft Exchange Server

More information

EMC VSPEX END-USER COMPUTING

EMC VSPEX END-USER COMPUTING DESIGN GUIDE EMC VSPEX END-USER COMPUTING VMware Horizon 6.0 with View and VMware vsphere for up to 2,000 Virtual Desktops Enabled by EMC VNX and EMC Data Protection EMC VSPEX Abstract This describes how

More information

EMC INFRASTRUCTURE FOR VMWARE VIEW 5.0

EMC INFRASTRUCTURE FOR VMWARE VIEW 5.0 Reference Architecture EMC INFRASTRUCTURE FOR VMWARE VIEW 5.0 EMC VNX Series (NFS), VMware vsphere 5.0, VMware View 5.0, VMware View Persona Management, and VMware View Composer 2.7 Simplify management

More information

EMC VSPEX FOR VIRTUALIZED MICROSOFT SQL SERVER 2012

EMC VSPEX FOR VIRTUALIZED MICROSOFT SQL SERVER 2012 DESIGN GUIDE EMC VSPEX FOR VIRTUALIZED MICROSOFT SQL SERVER 2012 EMC VSPEX Abstract This describes how to design virtualized Microsoft SQL Server resources on the appropriate EMC VSPEX Private Cloud for

More information

Dell EMC Ready Architectures for VDI

Dell EMC Ready Architectures for VDI Dell EMC Ready Architectures for VDI Designs for Citrix XenDesktop and XenApp for Dell EMC XC Family September 2018 H17388 Deployment Guide Abstract This deployment guide provides instructions for deploying

More information

EMC INFRASTRUCTURE FOR VMWARE VIEW 5.1

EMC INFRASTRUCTURE FOR VMWARE VIEW 5.1 Reference Architecture EMC INFRASTRUCTURE FOR VMWARE VIEW 5.1 EMC VNX Series (NFS), VMware vsphere 5.0, VMware View 5.1, VMware View Storage Accelerator, VMware View Persona Management, and VMware View

More information

EMC VSPEX FOR VIRTUALIZED MICROSOFT EXCHANGE 2010 WITH MICROSOFT HYPER-V

EMC VSPEX FOR VIRTUALIZED MICROSOFT EXCHANGE 2010 WITH MICROSOFT HYPER-V IMPLEMENTATION GUIDE EMC VSPEX FOR VIRTUALIZED MICROSOFT EXCHANGE 2010 WITH MICROSOFT HYPER-V EMC VSPEX Abstract This describes, at a high level, the steps required to deploy a Microsoft Exchange 2010

More information

EMC VSPEX FOR VIRTUALIZED MICROSOFT SQL SERVER 2012

EMC VSPEX FOR VIRTUALIZED MICROSOFT SQL SERVER 2012 DESIGN GUIDE EMC VSPEX FOR VIRTUALIZED MICROSOFT SQL SERVER 2012 EMC VSPEX Abstract This describes how to design virtualized Microsoft SQL Server resources on the appropriate EMC VSPEX Proven Infrastructure

More information

EMC VSPEX PRIVATE CLOUD

EMC VSPEX PRIVATE CLOUD VSPEX Proven Infrastructure EMC VSPEX PRIVATE CLOUD VMware vsphere 5.1 for up to 250 Virtual Machines Enabled by Microsoft Windows Server 2012, EMC VNX, and EMC Next- EMC VSPEX Abstract This document describes

More information

EMC VSPEX FOR VIRTUALIZED ORACLE DATABASE 12c OLTP

EMC VSPEX FOR VIRTUALIZED ORACLE DATABASE 12c OLTP DESIGN GUIDE EMC VSPEX FOR VIRTUALIZED ORACLE DATABASE 12c OLTP Enabled by EMC VNXe and EMC Data Protection VMware vsphere 5.5 Red Hat Enterprise Linux 6.4 EMC VSPEX Abstract This describes how to design

More information

Virtualizing SQL Server 2008 Using EMC VNX Series and VMware vsphere 4.1. Reference Architecture

Virtualizing SQL Server 2008 Using EMC VNX Series and VMware vsphere 4.1. Reference Architecture Virtualizing SQL Server 2008 Using EMC VNX Series and VMware vsphere 4.1 Copyright 2011, 2012 EMC Corporation. All rights reserved. Published March, 2012 EMC believes the information in this publication

More information

EMC VSPEX END-USER COMPUTING

EMC VSPEX END-USER COMPUTING DESIGN GUIDE EMC VSPEX END-USER COMPUTING Citrix XenDesktop EMC VSPEX Abstract This describes how to design an EMC VSPEX end-user computing solution for Citrix XenDesktop using EMC ScaleIO and VMware vsphere

More information

Dell EMC Ready System for VDI on XC Series

Dell EMC Ready System for VDI on XC Series Dell EMC Ready System for VDI on XC Series Citrix XenDesktop for Dell EMC XC Series Hyperconverged Appliance March 2018 H16969 Deployment Guide Abstract This deployment guide provides instructions for

More information

Dell EMC Ready System for VDI on VxRail

Dell EMC Ready System for VDI on VxRail Dell EMC Ready System for VDI on VxRail Citrix XenDesktop for Dell EMC VxRail Hyperconverged Appliance April 2018 H16968.1 Deployment Guide Abstract This deployment guide provides instructions for deploying

More information

DATA PROTECTION IN A ROBO ENVIRONMENT

DATA PROTECTION IN A ROBO ENVIRONMENT Reference Architecture DATA PROTECTION IN A ROBO ENVIRONMENT EMC VNX Series EMC VNXe Series EMC Solutions Group April 2012 Copyright 2012 EMC Corporation. All Rights Reserved. EMC believes the information

More information

EMC VSPEX FOR VIRTUALIZED MICROSOFT SQL SERVER 2012

EMC VSPEX FOR VIRTUALIZED MICROSOFT SQL SERVER 2012 DESIGN GUIDE EMC VSPEX FOR VIRTUALIZED MICROSOFT SQL SERVER 2012 EMC VSPEX Abstract This describes how to design virtualized Microsoft SQL Server resources on the appropriate EMC VSPEX Proven Infrastructure

More information

EMC VSPEX FOR VIRTUALIZED ORACLE DATABASE 12c OLTP

EMC VSPEX FOR VIRTUALIZED ORACLE DATABASE 12c OLTP IMPLEMENTATION GUIDE EMC VSPEX FOR VIRTUALIZED ORACLE DATABASE 12c OLTP VMware vsphere 5.5 Red Hat Enterprise Linux 6.4 EMC VSPEX Abstract This describes the high-level steps and best practices required

More information

EMC INFRASTRUCTURE FOR CITRIX XENDESKTOP 5.6

EMC INFRASTRUCTURE FOR CITRIX XENDESKTOP 5.6 Proven Solutions Guide EMC INFRASTRUCTURE FOR CITRIX XENDESKTOP 5.6 EMC VNX Series (NFS), VMware vsphere 5.0, Citrix XenDesktop 5.6, and Citrix Profile Manager 4.1 Simplify management and decrease TCO

More information

INTEGRATED INFRASTRUCTURE FOR VIRTUAL DESKTOPS ENABLED BY EMC VNXE3300, VMWARE VSPHERE 4.1, AND VMWARE VIEW 4.5

INTEGRATED INFRASTRUCTURE FOR VIRTUAL DESKTOPS ENABLED BY EMC VNXE3300, VMWARE VSPHERE 4.1, AND VMWARE VIEW 4.5 White Paper INTEGRATED INFRASTRUCTURE FOR VIRTUAL DESKTOPS ENABLED BY EMC VNXE3300, VMWARE VSPHERE 4.1, AND VMWARE VIEW 4.5 EMC GLOBAL SOLUTIONS Abstract This white paper describes a simple, efficient,

More information

Surveillance Dell EMC Storage with Cisco Video Surveillance Manager

Surveillance Dell EMC Storage with Cisco Video Surveillance Manager Surveillance Dell EMC Storage with Cisco Video Surveillance Manager Configuration Guide H14001 REV 1.1 Copyright 2015-2017 Dell Inc. or its subsidiaries. All rights reserved. Published May 2015 Dell believes

More information

EMC VSPEX PRIVATE CLOUD

EMC VSPEX PRIVATE CLOUD Proven Infrastructure EMC VSPEX PRIVATE CLOUD VMware vsphere 5.1 for up to 500 Virtual Machines Enabled by Microsoft Windows Server 2012, EMC VNX, and EMC Next- EMC VSPEX Abstract This document describes

More information

EMC VSPEX SERVER VIRTUALIZATION SOLUTION

EMC VSPEX SERVER VIRTUALIZATION SOLUTION Reference Architecture EMC VSPEX SERVER VIRTUALIZATION SOLUTION VMware vsphere 5 for 100 Virtual Machines Enabled by VMware vsphere 5, EMC VNXe3300, and EMC Next-Generation Backup EMC VSPEX April 2012

More information

EMC INFRASTRUCTURE FOR VMWARE VIEW 5.1

EMC INFRASTRUCTURE FOR VMWARE VIEW 5.1 Proven Solutions Guide EMC INFRASTRUCTURE FOR VMWARE VIEW 5.1 EMC VNX Series (NFS), VMware vsphere 5.0, VMware View 5.1, VMware View Storage Accelerator, VMware View Persona Management, and VMware View

More information

Dell EMC SAN Storage with Video Management Systems

Dell EMC SAN Storage with Video Management Systems Dell EMC SAN Storage with Video Management Systems Surveillance October 2018 H14824.3 Configuration Best Practices Guide Abstract The purpose of this guide is to provide configuration instructions for

More information

EMC STORAGE FOR MILESTONE XPROTECT CORPORATE

EMC STORAGE FOR MILESTONE XPROTECT CORPORATE Reference Architecture EMC STORAGE FOR MILESTONE XPROTECT CORPORATE Milestone multitier video surveillance storage architectures Design guidelines for Live Database and Archive Database video storage EMC

More information

EMC INFRASTRUCTURE FOR VMWARE VIEW 5.0

EMC INFRASTRUCTURE FOR VMWARE VIEW 5.0 Proven Solutions Guide EMC INFRASTRUCTURE FOR VMWARE VIEW 5.0 EMC VNX Series (NFS), VMware vsphere 5.0, VMware View 5.0, VMware View Persona Management, and VMware View Composer 2.7 Simplify management

More information

EMC INFRASTRUCTURE FOR CITRIX XENDESKTOP 7

EMC INFRASTRUCTURE FOR CITRIX XENDESKTOP 7 Reference Architecture EMC INFRASTRUCTURE FOR CITRIX XENDESKTOP 7 Simplify management and decrease total cost of ownership Guarantee a superior desktop experience Ensure a successful virtual desktop deployment

More information

EMC Integrated Infrastructure for VMware. Business Continuity

EMC Integrated Infrastructure for VMware. Business Continuity EMC Integrated Infrastructure for VMware Business Continuity Enabled by EMC Celerra and VMware vcenter Site Recovery Manager Reference Architecture Copyright 2009 EMC Corporation. All rights reserved.

More information

Dell EMC Ready Architectures for VDI

Dell EMC Ready Architectures for VDI Dell EMC Ready Architectures for VDI Designs for VMware Horizon 7 on Dell EMC XC Family September 2018 H17387 Deployment Guide Abstract This deployment guide provides instructions for deploying VMware

More information

Surveillance Dell EMC Storage with FLIR Latitude

Surveillance Dell EMC Storage with FLIR Latitude Surveillance Dell EMC Storage with FLIR Latitude Configuration Guide H15106 REV 1.1 Copyright 2016-2017 Dell Inc. or its subsidiaries. All rights reserved. Published June 2016 Dell believes the information

More information

EMC END-USER COMPUTING

EMC END-USER COMPUTING EMC END-USER COMPUTING Citrix XenDesktop 7.9 and VMware vsphere 6.0 with VxRail Appliance Scalable, proven virtual desktop solution from EMC and Citrix Simplified deployment and management Hyper-converged

More information

Copyright 2012 EMC Corporation. All rights reserved.

Copyright 2012 EMC Corporation. All rights reserved. 1 BUILDING INFRASTRUCTURES FOR THE POST PC ERA Umair Riaz vspecialist 2 The Way We Work Is Changing Access From Anywhere Applications On The Go Devices End User Options 3 Challenges Facing Your Business

More information

EMC VSPEX FOR VIRTUALIZED MICROSOFT EXCHANGE 2010

EMC VSPEX FOR VIRTUALIZED MICROSOFT EXCHANGE 2010 DESIGN GUIDE EMC VSPEX FOR VIRTUALIZED MICROSOFT EXCHANGE 2010 EMC VSPEX Abstract This describes how to design virtualized Microsoft Exchange Server 2010 resources on the appropriate EMC VSPEX Proven Infrastructures

More information

Surveillance Dell EMC Storage with Bosch Video Recording Manager

Surveillance Dell EMC Storage with Bosch Video Recording Manager Surveillance Dell EMC Storage with Bosch Video Recording Manager Sizing and Configuration Guide H13970 REV 2.1 Copyright 2015-2017 Dell Inc. or its subsidiaries. All rights reserved. Published December

More information

Copyright 2015 EMC Corporation. All rights reserved. Published in the USA.

Copyright 2015 EMC Corporation. All rights reserved. Published in the USA. This Reference Architecture Guide describes, in summary, a solution that enables IT organizations to quickly and effectively provision and manage Oracle Database as a Service (DBaaS) on Federation Enterprise

More information

EMC INFRASTRUCTURE FOR VMWARE VIEW 5.1

EMC INFRASTRUCTURE FOR VMWARE VIEW 5.1 Proven Solutions Guide EMC INFRASTRUCTURE FOR VMWARE VIEW 5.1 EMC VNX Series (FC), VMware vsphere 5.0, VMware View 5.1, VMware View Storage Accelerator, VMware View Persona Management, and VMware View

More information

EMC Unity Family EMC Unity All Flash, EMC Unity Hybrid, EMC UnityVSA

EMC Unity Family EMC Unity All Flash, EMC Unity Hybrid, EMC UnityVSA EMC Unity Family EMC Unity All Flash, EMC Unity Hybrid, EMC UnityVSA Version 4.0 Configuring Hosts to Access VMware Datastores P/N 302-002-569 REV 01 Copyright 2016 EMC Corporation. All rights reserved.

More information

Surveillance Dell EMC Storage with Digifort Enterprise

Surveillance Dell EMC Storage with Digifort Enterprise Surveillance Dell EMC Storage with Digifort Enterprise Configuration Guide H15230 REV 1.1 Copyright 2016-2017 Dell Inc. or its subsidiaries. All rights reserved. Published August 2016 Dell believes the

More information

EMC VSPEX FOR VIRTUALIZED MICROSOFT EXCHANGE 2013

EMC VSPEX FOR VIRTUALIZED MICROSOFT EXCHANGE 2013 DESIGN GUIDE EMC VSPEX FOR VIRTUALIZED MICROSOFT EXCHANGE 2013 EMC VSPEX Abstract This describes how to design a Microsoft Exchange Server 2013 solution on an EMC VSPEX Proven Infrastructure with Microsoft

More information

EMC Business Continuity for Microsoft Applications

EMC Business Continuity for Microsoft Applications EMC Business Continuity for Microsoft Applications Enabled by EMC Celerra, EMC MirrorView/A, EMC Celerra Replicator, VMware Site Recovery Manager, and VMware vsphere 4 Copyright 2009 EMC Corporation. All

More information

EMC VSPEX PRIVATE CLOUD

EMC VSPEX PRIVATE CLOUD Proven Infrastructure EMC VSPEX PRIVATE CLOUD Microsoft Windows Server 2012 with Hyper-V for up to 500 Virtual Machines Enabled by EMC VNX, and EMC Next-Generation Backup EMC VSPEX Abstract This document

More information

EMC Backup and Recovery for Microsoft SQL Server

EMC Backup and Recovery for Microsoft SQL Server EMC Backup and Recovery for Microsoft SQL Server Enabled by Microsoft SQL Native Backup Reference Copyright 2010 EMC Corporation. All rights reserved. Published February, 2010 EMC believes the information

More information

EMC Backup and Recovery for Microsoft Exchange 2007

EMC Backup and Recovery for Microsoft Exchange 2007 EMC Backup and Recovery for Microsoft Exchange 2007 Enabled by EMC CLARiiON CX4-120, Replication Manager, and Hyper-V on Windows Server 2008 using iscsi Reference Architecture Copyright 2009 EMC Corporation.

More information

Video Surveillance EMC Storage with Digifort Enterprise

Video Surveillance EMC Storage with Digifort Enterprise Video Surveillance EMC Storage with Digifort Enterprise Sizing Guide H15229 01 Copyright 2016 EMC Corporation. All rights reserved. Published in the USA. Published August 2016 EMC believes the information

More information

Copyright 2015 EMC Corporation. All rights reserved. Published in the USA.

Copyright 2015 EMC Corporation. All rights reserved. Published in the USA. This solution guide describes the data protection functionality of the Federation Enterprise Hybrid Cloud for Microsoft applications solution, including automated backup as a service, continuous availability,

More information

Microsoft Office SharePoint Server 2007

Microsoft Office SharePoint Server 2007 Microsoft Office SharePoint Server 2007 Enabled by EMC Celerra Unified Storage and Microsoft Hyper-V Reference Architecture Copyright 2010 EMC Corporation. All rights reserved. Published May, 2010 EMC

More information

Video Surveillance EMC Storage with Godrej IQ Vision Ultimate

Video Surveillance EMC Storage with Godrej IQ Vision Ultimate Video Surveillance EMC Storage with Godrej IQ Vision Ultimate Sizing Guide H15052 01 Copyright 2016 EMC Corporation. All rights reserved. Published in the USA. Published May 2016 EMC believes the information

More information

Cisco and EMC Release Joint Validated Design for Desktop Virtualization with Citrix XenDesktop. Daniel Chiu Business Development Manager, EMC

Cisco and EMC Release Joint Validated Design for Desktop Virtualization with Citrix XenDesktop. Daniel Chiu Business Development Manager, EMC Cisco and EMC Release Joint Validated Design for Desktop Virtualization with Citrix XenDesktop Daniel Chiu Business Development Manager, EMC 1 Cisco, Citrix, and EMC Partnership Collaborative solutions

More information

Storage Considerations for VMware vcloud Director. VMware vcloud Director Version 1.0

Storage Considerations for VMware vcloud Director. VMware vcloud Director Version 1.0 Storage Considerations for VMware vcloud Director Version 1.0 T e c h n i c a l W H I T E P A P E R Introduction VMware vcloud Director is a new solution that addresses the challenge of rapidly provisioning

More information

Dell EMC vsan Ready Nodes for VDI

Dell EMC vsan Ready Nodes for VDI Dell EMC vsan Ready Nodes for VDI Integration of VMware Horizon on Dell EMC vsan Ready Nodes April 2018 H17030.1 Deployment Guide Abstract This deployment guide provides instructions for deploying VMware

More information

Course CXS-203 Citrix XenServer 6.0 Administration

Course CXS-203 Citrix XenServer 6.0 Administration Course CXS-203 Citrix XenServer 6.0 Administration Overview In the Citrix XenServer 6.0 classroom training course, students are provided the foundation necessary to effectively install, configure, administer,

More information

VMware vstorage APIs FOR ARRAY INTEGRATION WITH EMC VNX SERIES FOR SAN

VMware vstorage APIs FOR ARRAY INTEGRATION WITH EMC VNX SERIES FOR SAN White Paper VMware vstorage APIs FOR ARRAY INTEGRATION WITH EMC VNX SERIES FOR SAN Benefits of EMC VNX for Block Integration with VMware VAAI EMC SOLUTIONS GROUP Abstract This white paper highlights the

More information

EMC VSPEX PRIVATE CLOUD

EMC VSPEX PRIVATE CLOUD EMC VSPEX PRIVATE CLOUD Microsoft Windows Server 2012 R2 with Hyper-V Enabled by EMC XtremIO and EMC Data Protection EMC VSPEX Abstract This describes the EMC VSPEX Proven Infrastructure solution for private

More information

EMC Infrastructure for Virtual Desktops

EMC Infrastructure for Virtual Desktops EMC Infrastructure for Virtual Desktops Enabled by EMC Celerra Unified Storage (NFS), VMware vsphere 4, and Citrix XenDesktop 4 Proven Solution Guide EMC for Enabled by

More information

Surveillance Dell EMC Storage with Synectics Digital Recording System

Surveillance Dell EMC Storage with Synectics Digital Recording System Surveillance Dell EMC Storage with Synectics Digital Recording System Configuration Guide H15108 REV 1.1 Copyright 2016-2017 Dell Inc. or its subsidiaries. All rights reserved. Published June 2016 Dell

More information

EMC Performance Optimization for VMware Enabled by EMC PowerPath/VE

EMC Performance Optimization for VMware Enabled by EMC PowerPath/VE EMC Performance Optimization for VMware Enabled by EMC PowerPath/VE Applied Technology Abstract This white paper is an overview of the tested features and performance enhancing technologies of EMC PowerPath

More information

EMC INFRASTRUCTURE FOR SUPERIOR END-USER COMPUTING EXPERIENCE

EMC INFRASTRUCTURE FOR SUPERIOR END-USER COMPUTING EXPERIENCE EMC INFRASTRUCTURE FOR SUPERIOR END-USER COMPUTING EXPERIENCE Enabled by the EMC XtremIO All-Flash Array, VMware vsphere 5.0, Citrix XenDesktop 5.6, and Citrix Provisioning Services 6.1 EMC Solutions Group

More information

Introduction to Virtualization. From NDG In partnership with VMware IT Academy

Introduction to Virtualization. From NDG In partnership with VMware IT Academy Introduction to Virtualization From NDG In partnership with VMware IT Academy www.vmware.com/go/academy Why learn virtualization? Modern computing is more efficient due to virtualization Virtualization

More information

Virtual Desktop Infrastructure (VDI) Bassam Jbara

Virtual Desktop Infrastructure (VDI) Bassam Jbara Virtual Desktop Infrastructure (VDI) Bassam Jbara 1 VDI Historical Overview Desktop virtualization is a software technology that separates the desktop environment and associated application software from

More information

VxRack System SDDC Enabling External Services

VxRack System SDDC Enabling External Services VxRack System SDDC Enabling External Services May 2018 H17144 Abstract This document describes how to enable external services for a VxRack System SDDC. Use cases included are Dell EMC Avamar-based backup

More information

VMware vsphere 5.0 STORAGE-CENTRIC FEATURES AND INTEGRATION WITH EMC VNX PLATFORMS

VMware vsphere 5.0 STORAGE-CENTRIC FEATURES AND INTEGRATION WITH EMC VNX PLATFORMS VMware vsphere 5.0 STORAGE-CENTRIC FEATURES AND INTEGRATION WITH EMC VNX PLATFORMS A detailed overview of integration points and new storage features of vsphere 5.0 with EMC VNX platforms EMC Solutions

More information

XenApp and XenDesktop 7.12 on vsan 6.5 All-Flash January 08, 2018

XenApp and XenDesktop 7.12 on vsan 6.5 All-Flash January 08, 2018 XenApp and XenDesktop 7.12 on vsan 6.5 All-Flash January 08, 2018 1 Table of Contents 1. Executive Summary 1.1.Business Case 1.2.Key Results 2. Introduction 2.1.Scope 2.2.Audience 3. Technology Overview

More information

Deploying VMware View in the Enterprise EMC Celerra NS-120. Reference Architecture.

Deploying VMware View in the Enterprise EMC Celerra NS-120. Reference Architecture. Deploying VMware View in the Enterprise EMC Celerra NS-120 EMC NAS Product Validation Corporate Headquarters Hopkinton, MA 01748-9103 1-508-435-1000 www.emc.com www.emc.com Copyright 2009 EMC Corporation.

More information

DELL EMC READY BUNDLE FOR VIRTUALIZATION WITH VMWARE AND FIBRE CHANNEL INFRASTRUCTURE

DELL EMC READY BUNDLE FOR VIRTUALIZATION WITH VMWARE AND FIBRE CHANNEL INFRASTRUCTURE DELL EMC READY BUNDLE FOR VIRTUALIZATION WITH VMWARE AND FIBRE CHANNEL INFRASTRUCTURE Design Guide APRIL 0 The information in this publication is provided as is. Dell Inc. makes no representations or warranties

More information

Installation and Cluster Deployment Guide for VMware

Installation and Cluster Deployment Guide for VMware ONTAP Select 9 Installation and Cluster Deployment Guide for VMware Using ONTAP Select Deploy 2.6 November 2017 215-12636_B0 doccomments@netapp.com Updated for ONTAP Select 9.3 Table of Contents 3 Contents

More information

EMC XTREMCACHE ACCELERATES VIRTUALIZED ORACLE

EMC XTREMCACHE ACCELERATES VIRTUALIZED ORACLE White Paper EMC XTREMCACHE ACCELERATES VIRTUALIZED ORACLE EMC XtremSF, EMC XtremCache, EMC Symmetrix VMAX and Symmetrix VMAX 10K, XtremSF and XtremCache dramatically improve Oracle performance Symmetrix

More information

CXS Citrix XenServer 6.0 Administration

CXS Citrix XenServer 6.0 Administration Course Overview View Course Dates & Register Today Students will learn to effectively install, configure, administer, and troubleshoot XenServer 6.0. Students will also learn how to configure a Provisioning

More information

EMC Infrastructure for Virtual Desktops

EMC Infrastructure for Virtual Desktops EMC Infrastructure for Virtual Desktops Enabled by EMC Celerra Unified Storage (FC), VMware vsphere 4.1, VMware View 4.5, and VMware View Composer 2.5 Reference Architecture Copyright 2010 EMC Corporation.

More information

vsphere Installation and Setup Update 2 Modified on 10 JULY 2018 VMware vsphere 6.5 VMware ESXi 6.5 vcenter Server 6.5

vsphere Installation and Setup Update 2 Modified on 10 JULY 2018 VMware vsphere 6.5 VMware ESXi 6.5 vcenter Server 6.5 vsphere Installation and Setup Update 2 Modified on 10 JULY 2018 VMware vsphere 6.5 VMware ESXi 6.5 vcenter Server 6.5 You can find the most up-to-date technical documentation on the VMware website at:

More information

Reference Architecture

Reference Architecture Reference Architecture EMC INFRASTRUCTURE FOR VIRTUAL DESKTOPS ENABLED BY EMC VNX, VMWARE vsphere 4.1, VMWARE VIEW 4.5, VMWARE VIEW COMPOSER 2.5, AND CISCO UNIFIED COMPUTING SYSTEM Reference Architecture

More information

Installation and Cluster Deployment Guide

Installation and Cluster Deployment Guide ONTAP Select 9 Installation and Cluster Deployment Guide Using ONTAP Select Deploy 2.3 March 2017 215-12086_B0 doccomments@netapp.com Updated for ONTAP Select 9.1 Table of Contents 3 Contents Deciding

More information

Citrix XenServer 6 Administration

Citrix XenServer 6 Administration Citrix XenServer 6 Administration Duration: 5 Days Course Code: CXS-203 Overview: In the Citrix XenServer 6.0 classroom training course, students are provided the foundation necessary to effectively install,

More information

Installation and Cluster Deployment Guide for VMware

Installation and Cluster Deployment Guide for VMware ONTAP Select 9 Installation and Cluster Deployment Guide for VMware Using ONTAP Select Deploy 2.8 June 2018 215-13347_B0 doccomments@netapp.com Updated for ONTAP Select 9.4 Table of Contents 3 Contents

More information

EMC Backup and Recovery for Microsoft Exchange 2007 SP1. Enabled by EMC CLARiiON CX4-120, Replication Manager, and VMware ESX Server 3.

EMC Backup and Recovery for Microsoft Exchange 2007 SP1. Enabled by EMC CLARiiON CX4-120, Replication Manager, and VMware ESX Server 3. EMC Backup and Recovery for Microsoft Exchange 2007 SP1 Enabled by EMC CLARiiON CX4-120, Replication Manager, and VMware ESX Server 3.5 using iscsi Reference Architecture Copyright 2009 EMC Corporation.

More information

CXS-203-1I Citrix XenServer 6.0 Administration

CXS-203-1I Citrix XenServer 6.0 Administration 1800 ULEARN (853 276) www.ddls.com.au CXS-203-1I Citrix XenServer 6.0 Administration Length 5 days Price $5115.00 (inc GST) Overview In the Citrix XenServer 6.0 classroom training course, students are

More information

Increase Scalability for Virtual Desktops with EMC Symmetrix FAST VP and VMware VAAI

Increase Scalability for Virtual Desktops with EMC Symmetrix FAST VP and VMware VAAI White Paper with EMC Symmetrix FAST VP and VMware VAAI EMC GLOBAL SOLUTIONS Abstract This white paper demonstrates how an EMC Symmetrix VMAX running Enginuity 5875 can be used to provide the storage resources

More information

Here is Your Customized Document

Here is Your Customized Document Here is Your Customized Document Your Configuration is: Manage LUNs Model - VNX5300 Storage Type - VNX for Block (SAN) Connection Type - Fibre Channel Switch or Boot from SAN Operating System - ESX Server

More information

EMC VSI for VMware vsphere Web Client

EMC VSI for VMware vsphere Web Client EMC VSI for VMware vsphere Web Client Version 6.9.2 Product Guide 302-000-051 REV 13 Copyright 2013-2016 EMC Corporation. All rights reserved. Published in the USA. Published June 2016 EMC believes the

More information

Video Surveillance EMC Storage with LENSEC Perspective VMS

Video Surveillance EMC Storage with LENSEC Perspective VMS Video Surveillance EMC Storage with LENSEC Perspective VMS Sizing Guide H14768 01 Copyright 2016 EMC Corporation. All rights reserved. Published in the USA. Published March, 2016 EMC believes the information

More information