Configuring and Monitoring from the Hub Manager

Size: px
Start display at page:

Download "Configuring and Monitoring from the Hub Manager"

Transcription

1 CHAPTER 3 Configuring and Monitoring from the Hub Manager This chapter explains how to use the FastHub 400 series Hub Manager on the FastHub 400M models to change the configuration settings and to monitor the hub or hub stack. This chapter assumes that you have already performed the following tasks described in this guide or in the FastHub /100 Series Cabling and Start Up: Connecting to the Console Port (FastHub 400M Models) section on page 2-14 Assigning IP Information to the Hub (FastHub 400M Models) section on page 2-16 Accessing the FastHub 400 Series Hub Manager section on page 2-21 Note Procedures for changing the configuration settings and detailed descriptions of the fields are also provided in the hub manager online help. Configuring and Monitoring from the Hub Manager 3-1

2 Navigating in the Hub Manager Navigating in the Hub Manager At the top of each hub manager page is a menu bar. Figure 3-1 describes the functions of the pages accessible from the menu bar. Note On Netscape Communicator only, when the cursor is above a topic on the menu bar, a pop-up briefly describes the options on that particular page. Figure 3-1 Hub Manager Menu Bar Display basic hub description; hub image; define password Define group parameters Define SNMP community strings; trap manager parameters Define console port; upgrade firmware options List neighboring devices; define Cisco Discovery Protocol parameters Define system-wide hub parameters Define port parameters; display Switched Uplink Module Management page FastHub /100 Series Installation and Configuration Guide

3 Saving Your Changes Saving Your Changes You can change the hub settings by entering information into fields, adding and removing list items, or selecting and deselecting check boxes. Click Apply to save your changes. Click Revert to discard all your unsaved changes and return the previous settings to the page. Note After you click Apply, you cannot revert to the previous settings. When you enter information in fields and select or deselect check boxes, the changes are saved and immediately take effect after you click Apply. When you add items to or remove them from lists, the changes take effect immediately. It is not necessary to click Apply. Note Wait approximately 30 seconds before turning off the hub to be sure the changes are saved. Configuring and Monitoring from the Hub Manager 3-3

4 Assigning or Changing Basic Hub Information Assigning or Changing Basic Hub Information You can assign or change basic descriptions about the hub from the hub manager Home Page (Figure 3-2). You can also assign a password to the hub management interfaces (hub manager and CLI-privileged commands) and monitor network activity through the live hub image. This page also provides a hotlink that opens a Telnet session to the hub command-line interface (CLI), in addition to hotlinks for contacting Cisco Systems resources. Click HOME on the menu bar to display the Home Page (Figure 3-2) and check and change hub information. Note This section provides detailed information about this page and procedures on changing the settings. When you are using the hub manager, click Help from the Home Page to access this information online. 3-4 FastHub /100 Series Installation and Configuration Guide

5 Assigning or Changing the Hub Name and Description Figure 3-2 Home Page HOME PORT GROUP IP SNMP CDP SYSTEM Procedures and detailed field descriptions are provided here. Initially assigned after the hub is installed. Can be changed from the IP Management page Assigning or Changing the Hub Name and Description You can assign or change the following information about the hub (be sure to click Apply to save changes): Name (maximum of 255 characters) Physical location (maximum of 255 characters) Name of the person responsible for managing the hub (maximum of 255 characters) Configuring and Monitoring from the Hub Manager 3-5

6 Assigning or Changing Basic Hub Information Assigning or Changing the Hub Password By default, no password is assigned to the hub management interfaces. You can restrict access to the hub manager or CLI-privileged commands by assigning a password. If a user fails to enter the password within a set number of attempts, the hub sends an SNMP trap to the SNMP trap manager to alert you, via in-band management messages, of the failed attempts. (For information about trap managers, see the Changing the SNMP Settings section on page 3-34.) When a password is assigned, the password prompt is displayed when you or any other user opens a hub manager session and displays the Home Page. The Home Page is redisplayed only after you enter the correct password. If the password prompt reappears, reenter the correct password. To assign or change the password to the hub manager or CLI-privileged commands: Step 1 Step 3 Step 4 Enter a character string (4 to 8 characters, case sensitive) in the Assign/Change Password field. Enter the same character string in the Reconfirm Password field. Click Apply. The connection with the hub is broken. The browser prompts you for the new password. Enter the new password at the password authentication prompt, and click OK. If you have forgotten or do not know the password, see the Recovering from a Lost or Forgotten Password section on page FastHub /100 Series Installation and Configuration Guide

7 Using the Hub Image to Monitor the Hub Using the Hub Image to Monitor the Hub The Home Page displays the front-panel image of the hub (Figure 3-3). The following sections provide information on how to use the hub image. Figure 3-3 Hub Image HOME PORT GROUP IP SNMP CDP SYSTEM Procedures and detailed field descriptions are provided here. Shows when another hub is connected to a stacking connector on the hub rear panel. Click a port to display its settings, status, and statistics. Click the Mode button to change the mode that the LEDs display for the fixed 10/100 ports. Click to display the settings, status, and statistics of an installed 10BaseT/100BaseTX or 100BaseFX switched uplink module Note The hub image on the Home Page does not display both the last fixed 10/100 network port and the uplink port (which are ports 12x and 12 on the FastHub 412 models or ports 24x and 24 on the FastHub 424 models). The last fixed port on the hub image represents both ports 12x and 12 or ports 24x and 24, depending on the model. In Figure 3-3, the hub image shows that a 10BaseT/100BaseTX switched uplink module is installed in the hub. Configuring and Monitoring from the Hub Manager 3-7

8 Assigning or Changing Basic Hub Information SYSTEM and RPS LEDs on the Hub Image The hub image on the Home Page shows the front-panel LED colors at the last poll interval and refreshes every 30 seconds. The LEDs show system and RPS status, port status, and port speed. Note The hub image does not show the 10 and 100 activity/collision LEDs. To find out if any of the hub ports are operating at 10 or 100 Mbps, check the actual 10 and 100 LEDs on the hub, or click the specific port on the image to display the settings on the Port Management Page. The SYSTEM LED on the hub image always displays green, showing that the hub is operating normally. It does not turn amber if a nonfatal POST failure exists. To verify that there are no nonfatal POST failures, check the actual SYSTEM LED on the hub or use the Diagnostic Console - Systems Engineering Menu (see the Using the Diagnostic Console - Systems Engineering Menu section on page 4-8). The colors of the RPS LED on the hub image show the RPS status (Table 3-1). Table 3-1 LED Color Blue (off) Solid green Flashing green Solid amber Descriptions of the RPS LED on the Hub Image Description Internal power supply is powered up. RPS is not powered up. RPS is powered up and operational. Internal power supply is not powered up. Internal power supply and RPS are both powered up and the internal power supply is powering the hub. If the internal power supply fails, the hub powers down and, after 15 seconds, restarts by using the power from the RPS. The hub goes through its normal boot sequence when it restarts. RPS is connected but not functioning properly. One of the power supplies in the RPS could be powered down or a fan on the RPS could have failed. 3-8 FastHub /100 Series Installation and Configuration Guide

9 Using the Hub Image to Monitor the Hub Mode Button and 10/100 Port LEDs on the Hub Image Click the Mode button on the hub image to change the mode of the port LEDs (Table 3-2). The default mode for the port LEDs is port status. The colors of the port LEDs on the hub image display the status or speed of the individual port (Table 3-3). When you select the port speed mode, the hub remains in that mode for approximately 30 seconds before returning to the default mode, port status. Note The hub image does not show the port LEDs in bandwidth-utilization mode (UTL). Note The hub image on the Home Page does not display both the last 10/100 network port and the uplink port (ports 12x and 12 on the FastHub 412 models or ports 24x and 24 on the FastHub 424 models). The LED above port 12 or 24 on the hub image represents both ports 12x and 12 or ports 24x and 24. Table 3-2 Changing Between Modes on the Hub Image For this Mode... Port status 100BaseT connections Push the Mode Button Until... The STAT LED is green. The SPD LED is green. Table 3-3 LED Color Port Status Blue (off) Solid green Solid amber Port Speed Blue (off) Green Descriptions of the Port LED on the Hub Image Description No link. Link operational. The port is partitioned. After a packet is successfully sent over this port, the LED is green (normal operating state). Port is connected to a 10BaseTX network device. Port is connected to a 100BaseTX network device. Configuring and Monitoring from the Hub Manager 3-9

10 Assigning or Changing Basic Hub Information Module Port LEDs on the Hub Image The image also shows if there is a 10BaseT/100BaseTX or 100BaseFX switched uplink module installed in the rear-panel expansion slot (Figure 3-4). The colors of the LEDs above the 10BaseT/100BaseTX switched uplink module show port status, duplex mode, and speed (Table 3-4). The colors of the LEDs above the 100BaseFX switched uplink module show port status and duplex mode (Table 3-5). Table 3-4 Descriptions of the 10/100 Module Port LEDs on the Hub Image LED Color Description 10/100 Module Port Status (left LED above the module port) Blue (off) No link. Solid green 10BaseT or 100BaseTX link operational. Flashing green 10BaseT or 100BaseTX link operational (with activity). 10/100 Module Port Duplex Mode (middle LED above the module port) Blue (off) Operating at half-duplex mode. Solid green Operating at full-duplex mode. 10/100 Module Port Speed (right LED above the module port) Blue (off) Operating at 10 Mbps. Solid green Operating at 100 Mbps. Table 3-5 Descriptions of the 100BaseFX Module Port LED on the Hub Image LED Color Description 100BaseFX Module Port Status (left LED above the module port) Blue (off) No link. Solid green 100BaseFX link operational. 10/100 Module Port Duplex Mode (right LED above the module port) Blue (off) Operating at half-duplex mode. Solid green Operating at full-duplex mode FastHub /100 Series Installation and Configuration Guide

11 Using the Hub Image to Monitor the Hub Hub Stack Image The Home Page displays an image of the hub stack if you have interconnected hubs (Figure 3-4). The stacking connectors on the stack image is green, showing which stacking connector on each hub is interconnected to another hub. Otherwise, the stacking connector is blue (off). Note Every hub in the stack must be powered up for it to be displayed on the Home Page. Otherwise, if a hub in the stack is powered down, the stack image shows one less hub in the stack even if the hub is still interconnected to the stack. However, the image does not show which specific hub is no longer active. You must check the actual hub stack to find out. If the stack image does not change after you have removed or added a hub to the stack, click the browser Reload button to refresh the stack image. Be sure you set the caching of pages to Every time in Netscape Communicator or Every visit to the page in Microsoft Internet Explorer. A radio button appears next to each hub in the stack image. If you click the radio button next to a specific hub and click PORT from the menu bar, the Port Management Page for that hub is displayed. The Port Management Page is also displayed when you select the radio button next to a specific hub on the stack image and then click on a port on that specific hub image. By default, the radio button next to the top hub in the stack image is selected, whether the top hub is a management hub or not. For more information about hub stacks and managing them, see the Managing the Hub Segments section on page 3-27 and Appendix C, FastHub Stacks. Configuring and Monitoring from the Hub Manager 3-11

12 Assigning or Changing Basic Hub Information Figure 3-4 Hub Stack Image HOME PORT GROUP IP SNMP CDP SYSTEM Shows when another hub is connected to a stacking connector on the hub rear panel. Click a port to display its settings, status, and statistics. Click the Mode button to change the mode that the LEDs display for the fixed 10/100 ports. Click to display the settings, status, and statistics of an installed 10BaseT/100BaseTX or 100BaseFX switched uplink module Note In Figure 3-4, the top hub on the stack image is a management hub, as indicated by the label Master, and is the primary management hub. The third hub in the stack is the secondary management hub. The second and fourth hubs are not management hubs. A 10BaseT/100BaseTX switched uplink module is installed in the second hub, and a 100BaseFX switched uplink module is installed in the fourth FastHub /100 Series Installation and Configuration Guide

13 Using Telnet to Open a CLI Session Using Telnet to Open a CLI Session Click Telnet to open a session on the hub command-line interface (CLI). Connecting to Cisco Systems Resources The Home Page provides these hotlinks to connect to Cisco Systems resources: Click Cisco Connection Online (CCO) to display the CCO home page ( which contains links to the support sites for downloading the latest software and displaying the latest Cisco documentation. Click Technical Assistance Center (TAC) to open a new message composition window to send to TAC (tac@cisco.com). You can also phone TAC at or Click HTML Interface Development Group to open a new message composition window to send to the hub manager development group (cs-html@cisco.com). Configuring and Monitoring from the Hub Manager 3-13

14 Changing the Port Settings Changing the Port Settings By default, each 10/100 network port and the 10/100 uplink port on the hub are enabled to transmit packets to and receive them from the device to which it is connected, automatically matching its speed. Click PORT on the menu bar or click the port on the hub image on the Home Page to display the Port Management Page (Figure 3-5), check the status of the port, and change the port settings. If you have a hub stack, click the radio button next to the specific hub image on the Home Page, and either click PORT from the menu bar or click the port on the specific hub image. The Port Management Page displays the port settings for the specific hub. Note This section provides detailed information about this page and procedures on changing the settings. When you are using the hub manager, click Help from the Port Management Page to access this information online FastHub /100 Series Installation and Configuration Guide

15 Changing the Port Settings Figure 3-5 Port Management Page HOME PORT GROUP IP SNMP CDP SYSTEM Displays the Switched Uplink Module Management page. Procedures and detailed field descriptions are provided here. Displays the statistics for a particular port Shows when the port is operating at 10 or 100 Mbps. Autonegotiation allows the port to match the speed of the device to which it is connected. Shows when the hub has partitioned (separated) the port from the network. The hub automatically partitions the port if, for example, there are too many collisions from the connected device. Shows when the port is able or unable to transmit and receive data. Configuring and Monitoring from the Hub Manager 3-15

16 Changing the Port Settings Enabling or Disabling a Port By default, all ports are enabled. To disable a port: Step 1 In the Link Status: Requested/Actual column, deselect the Enable check box. Click Apply. A linkdown trap is sent to the management station if you configured an SNMP manager. To reenable a port: Step 1 In the Link Status: Requested/Actual column, select the Enable check box. Click Apply. A linkup trap is sent to the management station if you configured an SNMP manager. Checking the Link and Partition Status The Link Status: Requested/Actual column displays the actual status of the port. Each port is always in one of these link states: Link Up Link Down Port can transmit and receive data. Port is unable to transmit or receive data. The Partition Status column displays whether or not the port has been partitioned by the hub, which usually happens as a result of excessive collisions or a network loop. Each port is always in one of these partition states: Partitioned Not Partitioned Port is isolated from the network communications. Port is not isolated from the network communications FastHub /100 Series Installation and Configuration Guide

17 Changing the Port Transmission Speed Changing the Port Transmission Speed By default, the ports automatically match the transmission speed of the attached device. To change the port speed: Step 1 From the Speed: Requested/Actual drop-down list, select 10 Mbps, 100 Mbps, or Auto (autonegotiate). The default is Auto. Click Apply. Note If the other device does not autonegotiate, the hub port automatically negotiates to 10 Mbps. Assigning or Changing a Port Name or Description To assign a name or description to a port: Step 1 In the Port Name/Description column, enter the port name or a description (up to 20 characters) of how the port is connected. Click Apply. Displaying the Switched Uplink Module Management Page Click Switched Uplink Module to display this page. Configuring and Monitoring from the Hub Manager 3-17

18 Changing the Port Settings Checking or Resetting Port Statistics From the Port Management Page, select a port, and click View to see the statistics for a particular port on the hub. The Detailed Port Statistics Page (Figure 3-6) for the selected port displays the port statistics. Table 3-6 lists the statistics displayed on the page. Click Reset Port Statistics to reset the statistics. The hub manager does not automatically refresh the statistics shown on this page. Click Reload to refresh the statistics shown on this page. Figure 3-6 Detailed Port Statistics Page HOME PORT GROUP IP SNMP CDP SYSTEM Procedures and detailed field descriptions are provided here Refreshes the statistics displayed on this page. Resets the statistics for the port FastHub /100 Series Installation and Configuration Guide

19 Checking or Resetting Port Statistics Table 3-6 Error Descriptions on the Detailed Port Statistics Page Packets Bytes FCS Errors Alignment Errors Packets Too Long Short Events Packets Too Short Collisions Late Events Very Long Events Data Rate Mismatches Autopartitions Total Errors Total number of packets received by the port. Total number of bytes received by the port. Number of frame check sequence (FCS) errors indicating that frames of data are being corrupted during transmission. Number of alignment errors (caused if all bytes are not received whole) received by the port. Number of packets received by the port that exceed the maximum size for IEEE frames. Number of packets received by the port that are smaller than runts, which are smaller than the minimum size for IEEE packets. Number of frames received by the hub that are smaller than the minimum size for IEEE frames. Number of times the hub and the connected device attempt to transmit at the same time. Number of frames that experienced a collision late in transmission. Number of packets that exceed the maximum length prescribed in IEEE Number of frames whose timing no longer matches the transmit frequency between the hub and the connected device. Number of times the port automatically partitions the segments attached to it. Total number of errors received by the port. Configuring and Monitoring from the Hub Manager 3-19

20 Changing the Module Port Settings Changing the Module Port Settings If you have an optional switched uplink module installed in the rear-panel expansion slot on the hub, you can manage the module port as you would the 10/100 network and uplink ports. Click PORT on the menu bar, and click Switched Uplink Module from the Port Management Page to display the Switched Uplink Module Management Page (Figure 3-7) and check and change the settings. You can also click the module port on the hub image on the Home Page to display the Switched Uplink Module Management Page. Note This section provides detailed information about this page and procedures on changing the settings. When you are using the hub manager, click Help on the Switched Uplink Module Management Page to access this information online. For more information about the switched uplink modules, see Appendix D, Switched Uplink Modules FastHub /100 Series Installation and Configuration Guide

21 Changing the Module Port Settings Figure 3-7 Switched Uplink Module Management Page HOME PORT GROUP IP SNMP CDP SYSTEM Procedures and detailed field descriptions are provided here. Shows on which hub in the stack the module is installed. Shows when the port is able or unable to transmit and receive data. Displays the statistics for a particular module. Shows when the module port is operating at halfor full-duplex mode. Autonegotiation allows the module port to match the duplex mode of the device to which it is connected Shows if the hub has a 10BaseT/100BaseTX or 100BaseFX switched uplink module installed. Shows when the module port is operating at 10 or 100 Mbps. Autonegotiation allows the 10BaseT/100BaseTX module port to match the speed of the device to which it is connected. Speed negotiation is not applicable to the 100BaseFX module port. Note Figure 3-7 shows the Switched Uplink Module Management Page. This example shows that hubs 1, 3, and 4 have modules installed. Hub 2 is powered down but still interconnected to the stack. Configuring and Monitoring from the Hub Manager 3-21

22 Changing the Module Port Settings Enabling or Disabling the Module Port By default, the module port is enabled. To disable the module port: Step 1 In the Status: Requested/Actual column, deselect the Enable check box. Click Apply. A linkdown trap is sent to the management station if you configured an SNMP manager. To reenable the module port: Step 1 In the Status: Requested/Actual column, select the Enable check box. Click Apply. A linkup trap is sent to the management station if you configured an SNMP manager. Checking the Module Port Status The Status: Requested/Actual column displays the actual status of the module port. The module port is always in one of these link states: Link Up Link Down Port can transmit and receive data. Port is unable to transmit or receive data. Checking the Type of Module Installed The Medium column displays the type of switched uplink module installed in the hub: 10BaseT/100BaseTX 100BaseFX-SC 10BaseT/100BaseTX switched uplink module is installed. 100BaseFX switched uplink module is installed FastHub /100 Series Installation and Configuration Guide

23 Changing the Module Port Transmission Speed Changing the Module Port Transmission Speed By default, the 10BaseT/100BaseTX module port automatically matches the transmission speed of the attached device. To change the module port transmission speed: Step 1 From the Speed: Requested/Actual drop-down list, select 10 Mbps, 100 Mbps, or Auto (autonegotiate). The default is Auto. The 10-Mbps and Auto options are available only to the 10BaseT/100BaseTX module port. Click Apply. Note If the other device does not autonegotiate, the hub port automatically negotiates to 10 Mbps. Speed negotiation does not apply to the 100BaseFX switched uplink module. Changing the Module Port Duplex Mode Full-duplex operation is simultaneous transmission of data in both directions across a link. For example, a 100BaseTX switched port operating in full-duplex mode can provide up to 200 Mbps of bandwidth across the switched link. When autonegotiation is selected on the module port, it automatically configures for full-duplex operation if the connected device also supports full duplex. If the attached device does not support full-duplex operation, the module port automatically configures to half-duplex operation. To change the module port duplex mode: Step 1 From the Duplex Mode: Requested/Actual drop-down list, select Half, Full, or Auto (autonegotiate). The default for the 10BaseT/100BaseTX module port is Auto. The default for the 100BaseFX module port is Half. Click Apply. Note If the other device does not autonegotiate, the hub port automatically negotiates to half duplex. Configuring and Monitoring from the Hub Manager 3-23

24 Changing the Module Port Settings Assigning or Changing a Module Port Name or Description To assign a name or description to a module port: Step 1 In the Port Name/Description column, enter the port name or a description (up to 20 characters) of how the module port is connected. Click Apply. Checking or Resetting Module Statistics From the Switched Uplink Module Management Page, select the hub on which the module is installed, and click View to see the statistics of the module. The Detailed Switched Uplink Module Statistics Page (Figure 3-8) displays the module statistics. Table 3-7 lists the statistics displayed on the page. Click Reset Switched Uplink Module Statistics to reset the statistics. The hub manager does not automatically refresh the statistics shown on this page. Click Reload to refresh the statistics shown on this page FastHub /100 Series Installation and Configuration Guide

25 Checking or Resetting Module Statistics Figure 3-8 Detailed Switched Uplink Module Statistics Page HOME PORT GROUP IP SNMP CDP SYSTEM Procedures and detailed field descriptions are provided here Refreshes the statistics displayed on this page. Resets the statistics for the switched uplink module. Configuring and Monitoring from the Hub Manager 3-25

26 Changing the Module Port Settings Table 3-7 Error Descriptions on the Detailed Switched Uplink Module Statistics Page Total Bytes Received Total Packets Received Broadcast Packets Received Multicast Packets Received CRC/Alignment Errors Undersize Packets Oversize Packets Fragments Very Long Events Collisions 64-Byte Packets Byte Packets Byte Packets Byte Packets Byte Packets Byte Packets Total number of bytes received by the port. Total number of packets received by the port. Total number of broadcast packets received by the port. Total number of multicast packets received by the port. Number of frames received by the port that are not an integral number of octets in length and do not pass the frame check sequence (FCS) test. Number of packets less than 64 bytes received by the port. Number of packets longer than 1518 bytes received by the port. Number of SMT packets received by the port. Number of packets that exceed the maximum length prescribed in IEEE Number of times the port and the connected device attempt to transmit at the same time. Number of packets received in these lengths in bytes FastHub /100 Series Installation and Configuration Guide

27 Managing the Hub Segments Managing the Hub Segments You can interconnect up to four FastHub 400 models (a maximum of 96 ports) and manage that hub stack as a single logical repeater. To provide management to the stack, the stack must include at least one FastHub 412M or FastHub 424M hub. You can have a second management hub in the stack to act as a redundant stack manager in case the primary manager fails. For complete information and guidelines on stacking hubs, see Appendix C, FastHub Stacks. By default, each hub in the stack is connected to the network. Click GROUP on the menu bar to display the Group Management Page (Figure 3-9), isolate a hub from the network, and display the statistics of each hub in the stack. Note This section provides detailed information about this page and procedures on changing the settings. When you are using the hub manager, click Help from the Group Management Page to access this information online. Figure 3-9 Group Management Page HOME PORT GROUP IP SNMP CDP SYSTEM Procedures and detailed field descriptions are provided here. Identifies the hubs in the stack. The hub physically located at the top of the stack is Group 1. Displays the statistics for a particular hub. Isolates a particular hub from the network. Connects a particular hub to the network Note Figure 3-9 shows the Group Management Page when there are at least two hubs in the stack. Configuring and Monitoring from the Hub Manager 3-27

28 Managing the Hub Segments This page displays the number of active hubs (groups) in the hub stack. Group 1 always represents the hub at the top of the stack, and the hub below Group 1 is Group 2, and so on. If you remove a hub from the stack, this page automatically renumbers the hubs accordingly. Note Every hub in the stack must be powered up for it to be displayed on the Home Page and on the Group Management Page. Otherwise, if a hub in the stack is powered down, the stack image shows one less hub in the stack even if the hub is still interconnected to the stack. However, the image does not show which specific hub is no longer active. You must check the actual hub stack to find out. If the stack image does not change after you have removed or added a hub to the stack, click the browser Reload button to refresh the stack image. Be sure you set the caching of pages to Every time in Netscape Communicator or Every visit to the page in Microsoft Internet Explorer. If a hub stack has more than one management hub, the upper management hub in the stack is the primary management hub. The lower management hub is the secondary management hub. To manage the hub stack, you can use the system information (such as the IP, CDP, and SNMP information) assigned to the primary management hub. The primary management hub also stores the port settings of each hub in the stack. If the primary management hub becomes inactive or is disconnected from the stack, the secondary management hub becomes the primary management hub and uses the same stack information. If a stack has only one management hub and another management hub is added to the stack, the system information from the management hub that has the longest system-up time is used by the topmost management hub. This happens if the new management hub is added either above or below the preexisting management hub. If you replace the only management hub in the stack with a different management hub, the stack will use the settings of the newly installed management hub. Note If you have a stack that has two management hubs and you remove one management hub from the stack, it will have the same IP address as the stack. Avoid IP conflict by changing the IP address of the removed management hub before you reuse it and connect it to another hub stack in the network FastHub /100 Series Installation and Configuration Guide

29 Connecting or Isolating a Hub Segment Connecting or Isolating a Hub Segment By default, each hub in the stack is connected to the network. To isolate a hub from the network: Step 1 Select Isolated from the Isolation Status drop-down list. You can use the Isolated option if you need to troubleshoot a specific hub in the stack and do not want to affect the devices to which that particular hub is connected. When you isolate a hub, keep the following considerations in mind: If you isolate a hub in the stack, the hubs above and below the isolated hub will still communicate with each other as long as the isolated hub is interconnected to the stack. If you isolate a hub in the stack other than the primary management hub, and your management station is not connected to the isolated hub, the Home Page will display the stack image, including the isolated hub. You can still manage the stack, including the isolated hub, from the hub manager. If your hub stack has only one management hub and you isolate that management hub, the Home Page will display only the image of the management hub (not the stack image). You will not be able to manage the stack from the hub manager. Note If you do not isolate a hub and if you keep it interconnected to the stack but only power down that hub, the hubs above and below that powered-down hub will still communicate with each other. However, you will not be able to manage that hub, and it will not be displayed from the hub manager. Click Apply. To reconnect an isolated hub to the network: Step 1 Select Connected from the Isolation Status drop-down list. Click Apply. Configuring and Monitoring from the Hub Manager 3-29

30 Managing the Hub Segments Checking or Resetting Hub Statistics From the Group Management Page, select the hub, and click View to see the statistics of a single hub or a hub in the hub stack. The Detailed Group Statistics Page (Figure 3-10) for the hub (group) you selected displays the hub statistics. Table 3-8 lists the statistics displayed on the page. Click Reset Group Statistics to reset the statistics. The hub manager does not automatically refresh the statistics shown on this page. Click Reload to refresh the statistics shown on this page. Figure 3-10 Detailed Group Statistics Page HOME PORT GROUP IP SNMP CDP SYSTEM Procedures and detailed field descriptions are provided here Refreshes the statistics displayed on this page. Resets the statistics for a particular hub FastHub /100 Series Installation and Configuration Guide

31 Checking or Resetting Hub Statistics Table 3-8 Error Descriptions on the Detailed Group Statistics Page Packets Bytes FCS Errors Alignment Errors Packets Too Long Short Events Packets Too Short Collisions Late Events Very Long Events Data Rate Mismatches Autopartitions Total Errors Total number of packets received by the port. Total number of bytes received by the port. Number of frame check sequence (FCS) errors indicating that frames of data are being corrupted during transmission. Number of alignment errors (caused if all bytes are not received whole) received by the port. Number of packets received by the port that exceed the maximum size for IEEE frames. Number of packets received by the port that are smaller than runts, which are smaller than the minimum size for IEEE packets. Number of frames received by the hub that are smaller than the minimum size for IEEE frames. Number of times the hub and the connected device attempt to transmit at the same time. Number of frames that experienced a collision late in transmission. Number of packets that exceed the maximum length prescribed in IEEE Number of frames whose timing no longer matches the transmit frequency between the hub and the connected device. Number of times the port automatically partitions the segments attached to it. Total number of errors received by the port. Configuring and Monitoring from the Hub Manager 3-31

32 Changing the Hub IP Information Changing the Hub IP Information IP information identifies the hub (or managed hub stack) to the network and is necessary to manage the hub (or hub stack) through the hub manager, the CLI, or SNMP. This information is usually assigned to the management hub after it is installed and initially started up. (See the Assigning IP Information to the Hub (FastHub 400M Models) section on page 2-16.) The IP Address field displays the current IP address of the hub. Click IP on the menu bar to display the IP Management Page (Figure 3-11) and change hub IP information. Note If you have a stack that has two management hubs and you remove one management hub from the stack, it will have the same IP address as the stack. Avoid IP conflict by changing the IP address of the removed management hub before you reuse it and connect it to another hub stack in the network. For complete information and guidelines on managing hub stacks, see the Managing the Hub Segments section on page 3-27 and the Managing a Hub Stack section on page C-6. Note This section provides detailed information about this page and procedures on changing the settings. When you are using the hub manager, click Help on the IP Management Page to access this information online. Figure 3-11 IP Management Page HOME PORT GROUP IP SNMP CDP SYSTEM Procedures and detailed field descriptions are provided here. User-Configured allows you to manually change the hub IP information. The IP address and subnet mask must be in the same subnet. BootP Get IP enables the hub to automatically assign hub IP information if it is connected to a network with a BootP server. When enabled, this option does not allow hub IP information to be manually changed FastHub /100 Series Installation and Configuration Guide

33 Changing the Hub IP Information Caution Changing the hub IP address on this page will end your hub manager session. To open a new session, enter the new IP address in the URL field if you are using Communicator (the Address field if you are using Internet Explorer). To manually change the hub IP information: Step 1 Select User-Configured from the IP State drop-down list. Note You can manually change the hub IP information only if the User-Configured option is enabled. Note Use the BootP Get IP option if you want the BootP (Boot Protocol) server to assign the IP information. The hub must be connected to a network that has a BootP server. The BootP Get IP option becomes active when you restart the hub. If this option is enabled, you cannot manually change IP information. The default is User-Configured. Enter a new IP address for the hub in the IP Address field. Caution If you enter a new address and click Apply, the hub manager loses contact with the hub. Enter the new IP address of the hub in the Location field if you are using Communicator (the Address field if you are using Internet Explorer) to redisplay the hub manager. Step 3 Step 4 Step 5 Enter the subnet mask for the hub. The subnet mask must be in the same subnet as the IP address. Enter the IP address of the default gateway. The default gateway is the router that the hub uses to reach IP subnets other than the local subnet to which the hub is attached. Click Apply. Configuring and Monitoring from the Hub Manager 3-33

34 Changing the SNMP Settings Changing the SNMP Settings SNMP provides the means to manage and monitor the hub (or managed hub stack) through the Management Information Base (MIB) objects. Additional information about SNMP and MIB objects is provided in the Overview of SNMP section on page 1-17 and the Accessing the MIB Files through SNMP section on page Click SNMP on the menu bar to display the SNMP Management Page (Figure 3-12) and check and change the SNMP settings. Note This section provides detailed information about this page and procedures on changing the settings. When you are using the hub manager, click Help on the SNMP Management Page to access this information online. Figure 3-12 SNMP Management Page HOME PORT GROUP IP SNMP CDP SYSTEM Procedures and detailed field descriptions are provided here. Passwords that allow read-only (Get requests) and read-write (Set requests) access to the hub MIB-object information. Up to four management stations can receive traps (alerts of certain events) generated by the hub. Use the traps to monitor the hub. Up to four management stations can issue write requests to change the hub configuration settings through the MIB variables FastHub /100 Series Installation and Configuration Guide

35 Changing the SNMP Read and Write Community Strings Changing the SNMP Read and Write Community Strings Community strings serve as passwords for SNMP messages. You can assign community strings that enable the hub to validate SNMP read and read-write requests from a management station. To change the SNMP Read community string: Step 1 Enter up to 32 characters in the Read Community String field. The default is public. Click Apply. To change the SNMP Write community string: Step 1 Enter up to 32 characters in the Write Community String field. The default is private. Click Apply. Assigning or Changing Trap Managers A trap manager is an SNMP management station that receives traps, which are the system alerts generated by the hub. If no trap manager is defined, no traps are issued. Up to four trap managers and their accompanying community strings can be entered. To assign a trap manager: Step 1 Enter the IP address and a community string (up to 32 characters) in the IP Address and Trap Manager Community String fields. Click Add. To remove a trap manager: Step 1 Select the manager from the Current list. Click Remove. Configuring and Monitoring from the Hub Manager 3-35

36 Changing the SNMP Settings Enabling or Disabling Trap Generation By default, the Enable Authentication Trap Generation check box is selected (meaning this parameter is enabled). When this check box is selected, the hub generates authentication traps that alert a management station to SNMP requests that are not accompanied by a valid community string. However, even if this parameter is enabled, no trap can be generated if no trap manager addresses are specified. (For information about trap manager settings, see the Assigning or Changing Trap Managers section on page 3-35). If you change this check box, click Apply to save your changes. By default, the Enable Link Up/Link Down Trap Generation check box is selected (meaning this parameter is enabled). If you change this check box, click Apply to save your changes. The hub generates linkdown traps when a port is suspended or disabled for these reasons: User disables the port. Link is down. The hub generates linkup traps when a port is enabled for these reasons: Presence of linkbeat. Management intervention enables the port. Assigning or Changing Write Managers A write manager is an SNMP management station that can issue write requests to the hub. Up to four IP addresses of stations can be defined. To assign a write manager: Step 1 Enter the management station IP address in the IP Address field. Click Add. To remove a write manager: Step 1 Select the manager from the Current list. Click Remove FastHub /100 Series Installation and Configuration Guide

37 Changing the CDP Settings Changing the CDP Settings The Cisco Discovery Protocol (CDP) enables the hub (or managed hub stack) to advertise its existence to other Cisco devices in the network. When CDP is enabled, the hub manager and network management applications have an accurate picture of the network at any time because CDP gathers information about device types, links between devices, and the number of interfaces within each device. By default, the hub is CDP-enabled. Click CDP on the menu bar to display the CDP Management Page (Figure 3-13) and check and change the CDP settings. Note This section provides detailed information about this page and procedures on changing the settings. When you are using the hub manager, click Help on the CDP Management Page to access this information online. Figure 3-13 CDP Management Page HOME PORT GROUP IP SNMP CDP SYSTEM Opens the web console of a connected neighboring device. Procedures and detailed field descriptions are provided here. Allow or not allow exchanging CDP messages between the hub and other Cisco devices. Opens a Telnet session and logs you into a connected neighboring device. Displays detailed information about a connected neighboring device. Length of time a neighboring device retains CDP information it received from this hub. The packet hold time should be higher than the packet transmission time. Length of time between transmissions of CDP mesages. The packet transmission time should be lower than the packet hold time Configuring and Monitoring from the Hub Manager 3-37

38 Changing the CDP Settings Displaying CDP Neighbors The Discovered Neighboring Devices list shows the devices with which the hub exchanges CDP messages. To display information about neighboring devices: Step 1 From the Discovered Neighboring Devices list, select a device. Click one of these buttons: Click Browse to access the web console of a neighboring device. The neighbor must be a device that has web-console support. Click Telnet to open a Telnet session and log into a neighboring device. Click Details to display the detailed CDP information currently stored in the hub. Enabling and Disabling CDP By default, CDP is enabled on the hub. If you do not want the hub to exchange information with Cisco devices, you can disable CDP on the hub. To disable CDP: Step 1 Deselect the Enable CDP check box. Click Apply. To reenable CDP: Step 1 Select the Enable CDP check box. Click Apply FastHub /100 Series Installation and Configuration Guide

39 Changing the CDP Settings Changing the CDP Settings To change the global CDP settings for the hub: Step 1 In the Packet Hold Time field, enter the number of seconds (between 10 and 255) that a neighboring device retains the CDP neighbor information received from this hub. The default setting is 180 seconds. If a neighboring device does not receive a CDP message before the hold time expires, the device drops this hub as a neighbor. The packet hold time should be higher than the packet transmission time. Step 3 In the Packet Transmission Time field, enter the number of seconds (between 5 and 900) between transmissions of CDP messages. The default is 60 seconds. The packet transmission time should be lower than the packet hold time. Click Apply. Configuring and Monitoring from the Hub Manager 3-39

40 Changing the System Configuration Changing the System Configuration Cisco periodically provides new firmware to implement enhancements and maintenance releases. New firmware releases can be downloaded from Cisco Connection Online (CCO), the Cisco Systems customer web site available at the following URLs: www-china.cisco.com, and www-europe.cisco.com. The Firmware Version field displays the firmware version in use. You can download the latest hub firmware from a TFTP server. Note When you download the firmware permanently to Flash memory, the hub does not respond to commands for approximately 1 minute. This is normal and correct. Do not turn off the hub. The hub then resets and begins using the new firmware. Caution If you interrupt the transfer by turning the hub off and on, the firmware could get corrupted. For recovery procedures, see the Recovering from Corrupted Firmware section on page If you want to upgrade the firmware of the management hub, click SYSTEM on the menu bar to display the System Configuration Page (Figure 3-14). Note This section provides detailed information about this page and procedures on changing the settings. When you are using the hub manager, click Help on the System Configuration Page to access this information online FastHub /100 Series Installation and Configuration Guide

41 Changing the System Configuration Figure 3-14 System Configuration Page HOME PORT GROUP IP SNMP CDP SYSTEM Procedures and detailed field descriptions are provided here. Before downloading the upgrade file to the hub via XMODEM protocol, make sure the settings of the hub console port and management station match. Displays the firmware version used by the hub. Permanently downloads the new firmware to Flash memory. Temporarily downloads the new firmware to DRAM. After a power cycle, the hub uses the previous firmware version Configuring and Monitoring from the Hub Manager 3-41

42 Changing the System Configuration Configuring the Hub Console Port The console port on the hub provides terminal and PC access to the hub. After the hub is installed, be sure to configure the console port settings of the hub to match the settings of the terminal or PC. These are the default settings of the hub console port: Baud rate default is Data bits default is 8. Note If data bits is 8, set parity to None. Stop bits default is 1. Parity settings default is None. If you change any of these settings, click Apply to save your changes. Changing the CLI Inactivity Timeout Setting You can change the number of seconds that the CLI can wait without activity before it times out. After timeout, you must reenter the password. To change the inactivity timeout parameter: Step 1 Enter the number of seconds (0, or 30 to 65500) in the CLI Inactivity Timeout field. The default is 0 (which means the console session does not time out). Click Apply FastHub /100 Series Installation and Configuration Guide

43 Upgrading the Hub Firmware Upgrading the Hub Firmware The Firmware Version field displays the firmware version used by the hub. You can upgrade the firmware by following these steps to download the latest firmware from a TFTP server to your hub: Step 1 Step 3 Step 4 Step 5 In the Server IP Address field, enter the IP address of the TFTP server on which the upgrade file is located. Enter the upgrade filename (up to 80 characters) in the Filename for Firmware Upgrades field. Select one of these download modes: Permanent to download the firmware to Flash memory. Temporary to download the firmware to DRAM. Use this option to test the new firmware before overriding the previous firmware. After a power cycle, the hub discards the new firmware and uses the previous firmware. The default is Permanent. Click System TFTP Upgrade to download the upgrade file from the TFTP server to the hub. Click OK on the confirmation prompt. Note When you download the firmware permanently to Flash memory, the hub does not respond to commands for approximately 1 minute. This is normal and correct. Do not turn off the hub. The hub then resets and begins using the new firmware. Caution If you interrupt the transfer by turning the hub off and on, the firmware could get corrupted. For recovery procedures, see the Recovering from Corrupted Firmware section on page Configuring and Monitoring from the Hub Manager 3-43

Out-of-Band Management

Out-of-Band Management CHAPTER 4 Out-of-Band Management Note Out-of-band management requires the optional Cisco network management module (NMM). This chapter describes how to manage your hub or hub stack using the management

More information

Configuring and Monitoring from the Switch Manager

Configuring and Monitoring from the Switch Manager CHAPTER 3 Configuring and Monitoring from the Switch Manager This chapter explains how to use the switch manager to change the configuration settings and to monitor the switch. This chapter assumes that

More information

Troubleshooting. Diagnosing Problems CHAPTER

Troubleshooting. Diagnosing Problems CHAPTER CHAPTER 5 Troubleshooting There are several ways to troubleshoot installation and performance problems. For instance, the front-panel LEDs provide the quickest way to evaluate switch operation. The statistics

More information

Managing Your Switches

Managing Your Switches CHAPTER 3 Managing Your Switches You can use the IOS Release 12.0(5)XP software to manage a single switch, a stack of switches that are managed individually, or a cluster of switches that is managed through

More information

Overview. Switch Features CHAPTER

Overview. Switch Features CHAPTER CHAPTER 1 Overview The 2900 XL series switches are workgroup Ethernet switches that supply autosensing 10BaseT or 100BaseT connections on all ports. Expansion slots on Catalyst 2912MF XL and 2924M XL switches

More information

Switched Uplink Modules

Switched Uplink Modules APPENDIX D Switched Uplink Modules When installed in a FastHub 400 model, each 10BaseT/100BaseTX and 100BaseFX switched uplink module provides a separate switched collision domain for traffic to the workgroup

More information

Troubleshooting 1240AG Series Autonomous Access Points

Troubleshooting 1240AG Series Autonomous Access Points CHAPTER 3 Troubleshooting 1240AG Series Autonomous Access Points This chapter provides troubleshooting procedures for basic problems with the 1240AG series autonomous access point (AIR-AP1242AG or AIR-AP1242G).

More information

VERTICAL HORIZON VH-2402S FAST ETHERNET SWITCH MANAGEMENT GUIDE

VERTICAL HORIZON VH-2402S FAST ETHERNET SWITCH MANAGEMENT GUIDE VERTICAL HORIZON VH-2402S FAST ETHERNET SWITCH MANAGEMENT GUIDE 9033645-01 Notice Only qualified personnel should perform installation procedures. NOTICE Enterasys Networks reserves the right to make

More information

Troubleshooting Autonomous Access Points

Troubleshooting Autonomous Access Points CHAPTER 3 This chapter provides troubleshooting procedures for basic problems with the autonomous access point (model: AIR-AP1131AG or AIR-AP1131G). For the most up-to-date, detailed troubleshooting information,

More information

C H A P T E R Figure 1-1 Modular Stacked Network System 1-1

C H A P T E R Figure 1-1 Modular Stacked Network System 1-1 CHAPTER 1 Overview The FastHub 316T and FastHub 316C are compatible with other Cisco modular, stackable products that can be managed from a central location. The routers, switches, and hubs that make up

More information

Troubleshooting. Introduction CHAPTER

Troubleshooting. Introduction CHAPTER CHAPTER 8 Troubleshooting Revised: December 21, 2012, Introduction Your Cisco SCE 8000 GBE platform went through extensive testing before leaving the factory. However, if you encounter problems starting

More information

Troubleshooting 1240AG Series Lightweight Access Points

Troubleshooting 1240AG Series Lightweight Access Points CHAPTER 4 Troubleshooting 1240AG Series Lightweight Access Points This chapter provides troubleshooting procedures for basic problems with the 1240AG series lightweight access point (AIR-LAP1242AG or AIR-LAP1242G).

More information

Troubleshooting Lightweight Access Points

Troubleshooting Lightweight Access Points CHAPTER 4 This chapter provides troubleshooting procedures for basic problems with the 1130AG series lightweight access point (model: AIR-LAP1131AG or AIR-LAP1131G). For the most up-to-date, detailed troubleshooting

More information

Configuring the Catalyst 3920

Configuring the Catalyst 3920 CHAPTER 5 Configuring the Catalyst 3920 You might not have to configure the Catalyst 3920 for it to work in your network; it is shipped with default configuration parameters and can function with these

More information

Getting Started with the VG248

Getting Started with the VG248 CHAPTER 2 Before you can configure the telephony features on the VG248 to interact with the analog phones, you must first configure the basic network, SNMP, and password settings. These settings enable

More information

Managing Switches. Finding More Information About IOS Commands CHAPTER

Managing Switches. Finding More Information About IOS Commands CHAPTER CHAPTER 4 This chapter describes how to use the device-management features of the Cluster Management Suite (CMS). The features described in this chapter can all be implemented through Visual Switch Manager

More information

Product Overview. Features CHAPTER

Product Overview. Features CHAPTER CHAPTER 1 This chapter provides these topics that describe the Catalyst 2900 series XL switches, hereafter referred to as the switches. Switch features, including management options Descriptions of the

More information

Assigning the Switch IP Address and Default Gateway

Assigning the Switch IP Address and Default Gateway CHAPTER 4 Assigning the Switch IP Address and Default Gateway This chapter describes how to create the initial switch configuration (for example, assigning the switch IP address and default gateway information)

More information

Getting Started with CMS

Getting Started with CMS CHAPTER 3 This chapter provides these topics about the Cluster Management Suite (CMS) software: Features, page 3-2 Front Panel View, page 3-5 Topology View, page 3-11 Menus and Toolbar, page 3-16 Interaction

More information

Overview. About the Catalyst 2820 and Catalyst 1900 Switches CHAPTER

Overview. About the Catalyst 2820 and Catalyst 1900 Switches CHAPTER CHAPTER 1 Overview This chapter describes the Enterprise Edition software features for Catalyst 2820 and Catalyst 1900 switches. It also describes the feature default settings and shows the management

More information

Cisco Discovery Protocol Version 2

Cisco Discovery Protocol Version 2 Cisco Discovery Protocol (formerly known as CDP) is a Layer 2, media-independent, and network-independent protocol that runs on Cisco devices and enables networking applications to learn about directly

More information

Using the HP Web Browser Interface

Using the HP Web Browser Interface 4 Contents Overview..................................................... 4-2 General Features.............................................. 4-3 Starting an HP Web Browser Interface Session with the Switch..

More information

Chapter 2. Switch Concepts and Configuration. Part I

Chapter 2. Switch Concepts and Configuration. Part I Chapter 2 Switch Concepts and Configuration Part I CCNA3-1 Chapter 2-1 Note for Instructors These presentations are the result of a collaboration among the instructors at St. Clair College in Windsor,

More information

Lab Troubleshooting LAN Connectivity

Lab Troubleshooting LAN Connectivity Lab 9.2.4 Troubleshooting LAN Connectivity Device Host Name Interface IP Address Subnet Mask Default Gateway Switch Port R1 R1 Fast Ethernet 0/0 192.168.1.1 255.255.255.0 N/A Fast Ethernet 0/2 S1 S1 VLAN

More information

Managing Switch Stacks

Managing Switch Stacks Finding Feature Information, page 1 Prerequisites for Switch Stacks, page 1 Restrictions for Switch Stacks, page 2 Information About Switch Stacks, page 2 How to Configure a Switch Stack, page 14 Troubleshooting

More information

Management Software AT-S79. User s Guide. For use with the AT-GS950/16 and AT-GS950/24 Smart Switches. Version Rev.

Management Software AT-S79. User s Guide. For use with the AT-GS950/16 and AT-GS950/24 Smart Switches. Version Rev. Management Software AT-S79 User s Guide For use with the AT-GS950/16 and AT-GS950/24 Smart Switches Version 1.0.0 613-000207 Rev. A Copyright 2005 Allied Telesyn, Inc. All rights reserved. No part of this

More information

New Product: Cisco Catalyst 2950 Series Fast Ethernet Desktop Switches

New Product: Cisco Catalyst 2950 Series Fast Ethernet Desktop Switches New Product: Cisco Catalyst 2950 Series Fast Ethernet Desktop Switches Product Overview The Cisco Catalyst 2950 Series of fixed configuration, wire-speed Fast Ethernet desktop switches delivers premium

More information

Troubleshooting. LRE Statistics CHAPTER

Troubleshooting. LRE Statistics CHAPTER 28 CHAPTER This chapter describes how to identify and resolve software problems related to the IOS software. Depending on the nature of the problem, you can use the command-line interface (CLI) or the

More information

Overview of the Hub CHAPTER

Overview of the Hub CHAPTER CHAPTER 1 Overview of the Hub The Cisco Micro Hub is a small, desktop hub used for connecting network devices in a small branch or remote office. You can connect up to eight network devices to one Cisco

More information

VOL Volition Managed Ethernet Switch. User Guide. Innovation

VOL Volition Managed Ethernet Switch. User Guide. Innovation VOL-0215 Volition Managed Ethernet Switch User Guide Innovation 1 2 Table of Contents 1.0 Introduction... 4 2.0 Configuring Initial Parameters with the Terminal... 5 3.0 Installing and Opening Volition

More information

Viewing System Status, page 404. Backing Up and Restoring a Configuration, page 416. Managing Certificates for Authentication, page 418

Viewing System Status, page 404. Backing Up and Restoring a Configuration, page 416. Managing Certificates for Authentication, page 418 This chapter describes how to maintain the configuration and firmware, reboot or reset the security appliance, manage the security license and digital certificates, and configure other features to help

More information

Troubleshooting the Cisco RPS

Troubleshooting the Cisco RPS CHAPTER 5 The key to troubleshooting is to isolate the problem to a specific subsystem. Start by reading the LEDs on the front panel of the Cisco RPS and any error messages displayed on the external device

More information

Trademarks. Statement of Conditions by NETGEAR, Inc. All rights reserved.

Trademarks. Statement of Conditions by NETGEAR, Inc. All rights reserved. 2004 by NETGEAR, Inc. All rights reserved. Trademarks @2004 NETGEAR, Inc. NETGEAR, the Netgear logo, The Gear Guy and Everybody s connecting are trademarks of Netgear, Inc. in the United States and/or

More information

Switch Memory and Configuration

Switch Memory and Configuration 6 Switch Memory and Configuration Contents Overview..................................................... 6-3 Overview of Configuration File Management................... 6-3 Using the CLI To Implement

More information

Index. B Boot software 5-2 Bridging architecture 7-6 Broadcast filter 8-55 limiting 8-22 Buffer port 7-9 Syslog 8-17, 8-20

Index. B Boot software 5-2 Bridging architecture 7-6 Broadcast filter 8-55 limiting 8-22 Buffer port 7-9 Syslog 8-17, 8-20 Index Numerics 10/100 mode 8-27 1000BaseLx 7-10 1000BaseSx 7-10 1000BaseT 7-10 100BaseFx 7-10 100BaseFx Ports 7-10 100BaseTx 7-10 10BaseT 7-10 802.3x Gigabit negotiation 8-29 9304M Routing Switch 2-9 9308M

More information

Linksys Stackable Switches

Linksys Stackable Switches TECHNICAL BULLETIN Linksys Stackable Switches How to Build Stacks and Understand Their Operation This document describes how to stack Linksys switches and covers advanced stacking information, as well

More information

Introduction to the Catalyst 3920

Introduction to the Catalyst 3920 CHAPTER 1 Introduction to the Catalyst 3920 This chapter contains the following information about the Catalyst 3920: Product Overview Physical Characteristics of the Catalyst 3920 System Architecture Product

More information

Management Software AT-S70. User s Guide. CONVERTEON Media Converter Products. Version Rev. B

Management Software AT-S70. User s Guide. CONVERTEON Media Converter Products. Version Rev. B Management Software AT-S70 User s Guide CONVERTEON Media Converter Products Version 1.1.0 613-50617-00 Rev. B Copyright 2005 Allied Telesyn, Inc. All rights reserved. No part of this publication may be

More information

Cisco Discovery Protocol Version 2

Cisco Discovery Protocol Version 2 Cisco Discovery Protocol (formerly known as CDP) is a Layer 2, media-independent, and network-independent protocol that runs on Cisco devices and enables networking applications to learn about directly

More information

Managing Software. Upgrading the Controller Software. Considerations for Upgrading Controller Software

Managing Software. Upgrading the Controller Software. Considerations for Upgrading Controller Software Upgrading the Controller Software, on page 1 Considerations for Upgrading Controller Software, on page 1 Upgrading Controller Software (GUI), on page 2 Upgrading Controller Software (CLI), on page 5 Predownloading

More information

Clustering Switches. Understanding Switch Clusters CHAPTER

Clustering Switches. Understanding Switch Clusters CHAPTER CHAPTER 5 This chapter provides the concepts and procedures to create and manage Catalyst 2975 switch clusters. Unless otherwise noted, the term switch refers to a standalone switch and to a switch stack.

More information

Web Browser User s Guide

Web Browser User s Guide Management Software AT-S63 Web Browser User s Guide For AT-9400Ts Stacks AT-S63 Version 4.0.0 for AT-9400 Basic Layer 3 Switches PN 613-001028 Rev B Copyright 2009 Allied Telesis, Inc. All rights reserved.

More information

Software Update C.09.xx Release Notes for the HP Procurve Switches 1600M, 2400M, 2424M, 4000M, and 8000M

Software Update C.09.xx Release Notes for the HP Procurve Switches 1600M, 2400M, 2424M, 4000M, and 8000M Software Update C.09.xx Release Notes for the HP Procurve Switches 1600M, 2400M, 2424M, 4000M, and 8000M Topics: TACACS+ Authentication for Centralized Control of Switch Access Security (page 7) CDP (page

More information

Initial Configuration

Initial Configuration 3 CHAPTER This chapter describes the initial configuration of the ML-Series card and contains the following major sections: Hardware Installation, page 3-1 Cisco IOS on the ML-Series Card, page 3-2 Startup

More information

Avaya P133G2. Quick Start Guide. Unpack. Rack mount (optional) Power up 3. Connect the cables 4. Configure 5. Run Web-based Manager (optional)

Avaya P133G2. Quick Start Guide. Unpack. Rack mount (optional) Power up 3. Connect the cables 4. Configure 5. Run Web-based Manager (optional) Avaya P133G2 Quick Start Guide Unpack Rack mount (optional) 1 2 Power up 3 Connect the cables 4 Configure 5 Run Web-based Manager (optional) 6 1 Unpack Check the package contents for the following: If

More information

Troubleshooting. Diagnosing Problems. Verify the Switch Module POST Results CHAPTER

Troubleshooting. Diagnosing Problems. Verify the Switch Module POST Results CHAPTER CHAPTER 3 This chapter describes these topics for troubleshooting problems:, page 3-1 Clearing the Switch Module IP Address and Configuration, page 3-5 Replacing a Failed Stack Member, page 3-5 Locating

More information

Configuring Interface Characteristics

Configuring Interface Characteristics Finding Feature Information, page 1 Information About, page 1 How to Configure Interface Characteristics, page 11 Monitoring Interface Characteristics, page 28 Configuration Examples for Interface Characteristics,

More information

Token Ring VLANs and Related Protocols

Token Ring VLANs and Related Protocols CHAPTER 4 Token Ring VLANs and Related Protocols A VLAN is a logical group of LAN segments, independent of physical location, with a common set of requirements. For example, several end stations might

More information

Configuring IP Addressing

Configuring IP Addressing 8 Configuring IP Addressing Contents Overview..................................................... 8-2.............................................. 8-2 Just Want a Quick Start with IP Addressing?....................

More information

Troubleshooting. Diagnosing Problems. Check Switch POST Results CHAPTER

Troubleshooting. Diagnosing Problems. Check Switch POST Results CHAPTER CHAPTER 3 This chapter describes these topics for troubleshooting problems: Diagnosing Problems, page 3-1 How to Clear the Switch IP Address and Configuration, page 3-4 Locating the Switch Serial Number,

More information

Monitoring Port Activity with Application Software

Monitoring Port Activity with Application Software CHAPTER 9 Monitoring Port Activity with Application Software This chapter explains how to monitor a port on the Catalyst 3200 using: Network Management System (NMS) using CiscoView or any application that

More information

Nighthawk S8000 Gaming & Streaming Advanced 8-Port Gigabit Ethernet Switch User Manual

Nighthawk S8000 Gaming & Streaming Advanced 8-Port Gigabit Ethernet Switch User Manual Nighthawk S8000 Gaming & Streaming Advanced 8-Port Gigabit Ethernet Switch User Manual Model GS808E March 2017 202-11732-01 350 E. Plumeria Drive San Jose, CA 95134 USA Support Thank you for purchasing

More information

Configuring Interfaces

Configuring Interfaces CHAPTER 9 This chapter defines the types of interfaces on the Cisco ME 3400 Ethernet Access switch and describes how to configure them. The chapter consists of these sections: Understanding Interface Types,

More information

DMC SNMP Module for Chassis-Based Media Converter Manual. Rev. 01 (JUN. 2002) 1907MCB RECYCLABLE

DMC SNMP Module for Chassis-Based Media Converter Manual. Rev. 01 (JUN. 2002) 1907MCB RECYCLABLE DMC-1002 SNMP Module for Chassis-Based Media Converter Manual Rev. 01 (JUN. 2002) 1907MCB10016000 RECYCLABLE TABLE OF CONTENTS ABOUT THIS GUIDE... 2 FEATURES...2 UNPACKING...2 CONFIGURING THE SYSTEM...

More information

Configuring Interfaces

Configuring Interfaces CHAPTER 9 This chapter defines the types of interfaces on the Cisco ME 3400 Ethernet Access switch and describes how to configure them. Understanding Interface Types, page 9-1 Using Interface Configuration

More information

Token Ring VLANs and Related Protocols

Token Ring VLANs and Related Protocols Token Ring VLANs and Related Protocols CHAPTER 4 Token Ring VLANs A VLAN is a logical group of LAN segments, independent of physical location, with a common set of requirements. For example, several end

More information

Managing Switch Stacks

Managing Switch Stacks CHAPTER 5 This chapter describes how to manage Catalyst 3750 switch stacks. For complete syntax and usage information for the commands used in this chapter, refer to the command reference for this release.

More information

MR2228-S2C. Stack Fast Ethernet Switch Management Guide

MR2228-S2C. Stack Fast Ethernet Switch Management Guide MR2228-S2C Stack Fast Ethernet Switch Management Guide Management Guide Stackable Fast Ethernet Switch with 24 10/100BASE-TX (RJ-45) Ports, 2 1000BASE-T Combination Ports (RJ-45/SFP), and 2 1000BASE-T/Stacking

More information

Troubleshooting. Diagnosing Problems CHAPTER

Troubleshooting. Diagnosing Problems CHAPTER CHAPTER 4 The LEDs on the front panel provide troubleshooting information about the switch. They show failures in the power-on self-test (POST), port-connectivity problems, and overall switch performance.

More information

Configuring the Cisco Discovery Protocol

Configuring the Cisco Discovery Protocol Finding Feature Information, page 1 Information About CDP, page 1 How to Configure CDP, page 3 Monitoring and Maintaining CDP, page 11 Additional References, page 12 Feature History and Information for

More information

ADMINISTRATION GUIDE Cisco Small Business 200 Series Smart Switch Administration Guide Release 1.1

ADMINISTRATION GUIDE Cisco Small Business 200 Series Smart Switch Administration Guide Release 1.1 ADMINISTRATION GUIDE Cisco Small Business 200 Series Smart Switch Administration Guide Release 1.1 10/100 Switches SF200-24, SF200-24P, SF200-48, SF200-48P Gigabit Switches SG200-18, SG200-26, SG200-26P,

More information

Smart Install Concepts

Smart Install Concepts CHAPTER 1 Smart Install is a plug-and-play configuration and image-management feature that provides zero-touch deployment for new switches. This means that a customer can ship a switch to a location, place

More information

Configuring and Managing the IP Camera

Configuring and Managing the IP Camera CHAPTER 3 The Cisco Video Surveillance IP Camera provides configuration windows that you use to configure and manage the IP camera. This chapter explains how to access the configuration windows, describes

More information

TFC-1600MM Media Conversion System. Management Configuring Guide

TFC-1600MM Media Conversion System. Management Configuring Guide TFC-1600MM Media Conversion System Management Configuring Guide CONFIGURING THE SYSTEM This chapter provides network managers and system administrators with information about how to configure the Media

More information

Installation. Package Contents CHAPTER

Installation. Package Contents CHAPTER CHAPTER 2 Installation This chapter describes how to install your Catalyst 3500 XL switches and interpret the power-on self-tests (POST) that ensure proper operation. Read the topics, and perform the procedures

More information

ProSAFE Easy-Mount 8-Port Gigabit Ethernet PoE+ Web Managed Switch

ProSAFE Easy-Mount 8-Port Gigabit Ethernet PoE+ Web Managed Switch ProSAFE Easy-Mount 8-Port Gigabit Ethernet PoE+ Web Managed Switch Model GS408EPP User Manual December 2016 202-11693-01 350 East Plumeria Drive San Jose, CA 95134 USA Support Thank you for purchasing

More information

Using the Offline Diagnostic Monitor Menu

Using the Offline Diagnostic Monitor Menu APPENDIX B Using the Offline Diagnostic Monitor Menu During the boot process, you can access the Offline Diagnostic Monitor (Offline DM) Main menu. The Offline DM Main menu allows you to perform the following

More information

Powered by Accton. ES Port Gigabit Web-Smart Switch. Management Guide.

Powered by Accton. ES Port Gigabit Web-Smart Switch. Management Guide. Powered by Accton ES4324 24-Port Gigabit Web-Smart Switch Management Guide www.edge-core.com Management Guide 24-Port Gigabit Web-Smart Switch with 24 1000BASE-T (RJ-45) Ports, and 4 Combination (RJ-45/SFP)

More information

Troubleshooting the Network Analysis Module. Netflow Data Export. Web Application CHAPTER

Troubleshooting the Network Analysis Module. Netflow Data Export. Web Application CHAPTER CHAPTER 5 This chapter describes how to troubleshoot the NAM and includes these sections: Netflow Data Export, page 5-1 Error Messages, page 5-9 Web Username and Password Guidelines, page 5-15 Supported

More information

Configure Controller and AP Settings

Configure Controller and AP Settings Configure SNMP Credentials for Rogue AP Tracing, on page 1 Configure Protocols for CLI Sessions, on page 2 Enable Unified AP Ping Reachability Settings on the Prime Infrastructure, on page 2 Refresh Controllers

More information

8-Port Gigabit Ethernet Smart Managed Plus Switch with Integrated Cable Management User Manual

8-Port Gigabit Ethernet Smart Managed Plus Switch with Integrated Cable Management User Manual 8-Port Gigabit Ethernet Smart Managed Plus Switch with Integrated Cable Management User Manual Model GS908E December 2017 202-11807-03 350 E. Plumeria Drive San Jose, CA 95134 USA Support Thank you for

More information

Lenovo Flex System SI Gb System Interconnect Module. Release Notes. for Networking OS 8.2

Lenovo Flex System SI Gb System Interconnect Module. Release Notes. for Networking OS 8.2 Lenovo Flex System SI4091 10Gb System Interconnect Module Release Notes for Networking OS 8.2 Note: Before using this information and the product it supports, read the general information in the Safety

More information

Using the Cable Monitor Tool

Using the Cable Monitor Tool APPENDIX B This appendix describes the Cisco ubr905 and Cisco ubr925 cable access routers Cable Monitor tool. The Cable Monitor is part of the router s onboard software that provides a web-based diagnostic

More information

Chapter. Managed Switch Software Monitoring. In This Chapter...

Chapter. Managed Switch Software Monitoring. In This Chapter... Managed Switch Software Monitoring Chapter 23 In This Chapter... System Information...3 2 Port and Power Status...3 4 Network Statistics...3 5 Spanning Tree Status...3 8 Real-Time Ring Status...3 10 Multicast

More information

16-SLOT IN-BAND MANAGEMENT CHASSIS

16-SLOT IN-BAND MANAGEMENT CHASSIS FCM-CHS2-XX 16-SLOT IN-BAND MANAGEMENT CHASSIS Network Management Manual Version 2.2 1 FCC Warning This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant

More information

Configuring Interface Characteristics

Configuring Interface Characteristics CHAPTER 12 This chapter defines the types of Catalyst 2975 interfaces and describes how to configure them. Unless otherwise noted, the term switch refers to a standalone switch and a switch stack. Understanding

More information

Catalyst 2960-X and 2960-XR Switch Hardware Guide

Catalyst 2960-X and 2960-XR Switch Hardware Guide 2960-X and 2960-XR Switch Hardware Guide The 2960-X and 2960-XRfamily of switches are Ethernet switches to which you can connect devices such as Cisco IP Phones, Cisco Wireless Access Points, workstations,

More information

Product Overview. Features CHAPTER

Product Overview. Features CHAPTER CHAPTER 1 The Catalyst 3750 Metro switch, also referred to as the switch, is a stackable metro Ethernet switch that can be used as customer-located equipment (CLE) to connect to enterprise customer routers

More information

LevelOne Broadband Routers

LevelOne Broadband Routers LevelOne Broadband Routers FBR-1100TX FBR-1400TX FBR-1401TX FBR-1700TX User's Guide TABLE OF CONTENTS CHAPTER 1 INTRODUCTION... 1 Features of your LevelOne Broadband Router... 1 Package Contents... 4

More information

Troubleshooting. Diagnosing Problems. Verify Switch Module POST Results. Verify Switch Module LEDs CHAPTER

Troubleshooting. Diagnosing Problems. Verify Switch Module POST Results. Verify Switch Module LEDs CHAPTER CHAPTER 3 This chapter describes these switch module troubleshooting topics: Diagnosing Problems, page 3-1 Resetting the Switch Module, page 3-4 How to Replace a Failed Stack Member, page 3-5 Diagnosing

More information

Table of Contents. Cisco Password Recovery Procedure for the Cisco Aironet Equipment

Table of Contents. Cisco Password Recovery Procedure for the Cisco Aironet Equipment Table of Contents Password Recovery Procedure for the Cisco Aironet Equipment...1 To get Cisco Aironet drivers, firmware and utility software, follow this link to the Cisco Wireless Software Center...1

More information

Cisco IOS Commands. abort CHAPTER

Cisco IOS Commands. abort CHAPTER CHAPTER 2 abort Use the abort VLAN database command to abandon the proposed new VLAN database, exit VLAN database mode, and return to privileged EXEC mode. abort This command has no arguments or keywords.

More information

Catalyst Switch Operations. 2000, Cisco Systems, Inc. 6-1

Catalyst Switch Operations. 2000, Cisco Systems, Inc. 6-1 Catalyst Switch Operations 2000, Cisco Systems, Inc. 6-1 Objectives Upon completion of this chapter, you will be able to perform the following tasks: Describe Layer 2 switching (bridging) operations Describe

More information

Maintenance Tasks CHAPTER

Maintenance Tasks CHAPTER CHAPTER 5 These topics describe the Maintenance tasks of Element Manager: Viewing Basic System Information, page 5-2 Configuring Basic System Information, page 5-4 Configuring Date and Time Properties,

More information

ProSAFE 8-Port 10-Gigabit Web Managed Switch Model XS708Ev2 User Manual

ProSAFE 8-Port 10-Gigabit Web Managed Switch Model XS708Ev2 User Manual ProSAFE 8-Port 10-Gigabit Web Managed Switch Model XS708Ev2 User Manual April 2016 202-11656-01 350 East Plumeria Drive San Jose, CA 95134 USA Support Thank you for purchasing this NETGEAR product. You

More information

Management Software AT-S101. User s Guide. For use with the AT-GS950/8POE Gigabit Ethernet WebSmart Switch. Version Rev.

Management Software AT-S101. User s Guide. For use with the AT-GS950/8POE Gigabit Ethernet WebSmart Switch. Version Rev. Management Software AT-S101 User s Guide For use with the AT-GS950/8POE Gigabit Ethernet WebSmart Switch Version 1.0.0 613-000985 Rev. A Copyright 2008 Allied Telesis, Inc. All rights reserved. No part

More information

MR2324-4C. 24-Port Intelligent Gigabit Ethernet Switch. Management Guide

MR2324-4C. 24-Port Intelligent Gigabit Ethernet Switch. Management Guide MR2324-4C 24-Port Intelligent Gigabit Ethernet Switch Management Guide Management Guide Intelligent Gigabit Ethernet Switch with 24 10/100/1000BASE-T (RJ-45) Ports, and 4 Combination RJ-45/SFP Ports E082004-R01

More information

Cajun P333R. Quick Start Guide. Unpack 1. Rack mount (optional) 2. Power up 3. Connect the cables 4. Configure 5. Run Web-based Manager (optional)

Cajun P333R. Quick Start Guide. Unpack 1. Rack mount (optional) 2. Power up 3. Connect the cables 4. Configure 5. Run Web-based Manager (optional) Cajun P333R Quick Start Guide Unpack 1 Rack mount (optional) 2 Power up 3 Connect the cables 4 Configure 5 Run Web-based Manager (optional) 6 1 Unpack Check the package contents for the following: E If

More information

Overview. Features CHAPTER

Overview. Features CHAPTER CHAPTER 2 This chapter provides these topics that describe the Catalyst 2955 switch, hereafter referred to as the switch. Features, page 2-1 Front-Panel Description, page 2-3 Rear-Panel Description, page

More information

LINKSYS SFE2000/SFE2000P FAST ETHERNET SWITCH. Linksys SFE2000/SFE2000P Fast Ethernet Switch Administration Guide. Release 1.0

LINKSYS SFE2000/SFE2000P FAST ETHERNET SWITCH. Linksys SFE2000/SFE2000P Fast Ethernet Switch Administration Guide. Release 1.0 LINKSYS SFE2000/SFE2000P FAST ETHERNET SWITCH Linksys SFE2000/SFE2000P Fast Ethernet Switch Administration Guide Release 1.0 2007 Cisco Systems, Inc. Specifications are subject to change without notice.

More information

Installing the Cisco Unified Videoconferencing 3545 MCU

Installing the Cisco Unified Videoconferencing 3545 MCU CHAPTER 2 Installing the Cisco Unified Videoconferencing 3545 MCU The Cisco Unified Videoconferencing 3545 MCU works together with a Cisco Unified Videoconferencing 3545 EMP Enhanced Media Processor (EMP)

More information

Initial Configuration on ML-Series Card

Initial Configuration on ML-Series Card CHAPTER 3 This chapter describes the initial configuration of the ML-Series card and contains the following major sections: Hardware Installation, page 3-1 Cisco IOS on the ML-Series Card, page 3-2 Startup

More information

Configuring and Managing the IP Camera

Configuring and Managing the IP Camera CHAPTER 3 The Cisco Video Surveillance IP Camera provides configuration windows that you use to configure and manage the IP camera. This chapter explains how to access the configuration windows, describes

More information

Cisco Prime Collaboration Deployment Configuration and Administration

Cisco Prime Collaboration Deployment Configuration and Administration Cisco Prime Collaboration Deployment Configuration and Administration Services, page 1 Limitations and Restrictions, page 5 Services After the installation of the Cisco Prime Collaboration Deployment platform,

More information

Maintenance Tasks CHAPTER

Maintenance Tasks CHAPTER CHAPTER 5 These topics describe the Maintenance tasks of Element Manager: Viewing Basic System Information, page 5-2 Configuring Basic System Information, page 5-3 Configuring Date and Time Properties,

More information

Oct 2007 Version 1.01

Oct 2007 Version 1.01 Oct 2007 Version 1.01 Table of Contents Introduction...4 System Requirement...4 Getting Started...4 Installing the Smart WLAN Manager...5 Discovering the Switch and AP...9 Understanding the Screen Layout...12

More information

Cisco Discovery Protocol Configuration Guide, Cisco IOS XE Release 3S (Cisco ASR 920 Series)

Cisco Discovery Protocol Configuration Guide, Cisco IOS XE Release 3S (Cisco ASR 920 Series) Cisco Discovery Protocol Configuration Guide, Cisco IOS XE Release 3S (Cisco ASR 920 Series) Cisco Discovery Protocol Version 2 2 Finding Feature Information 2 Prerequisites for Using Cisco Discovery Protocol

More information

Preface. Managed Media Converter Chassis System

Preface. Managed Media Converter Chassis System Preface The Managed Media Converter Chassis System supports the Media Converter Chassis to monitor the each Media Converter ( CO ) or Chassis Manager status and to configure advanced function of the Managed

More information

Configure the Catalyst Express 500 Switch with Cisco Network Assistant

Configure the Catalyst Express 500 Switch with Cisco Network Assistant Cisco SMB Support Assistant Cisco Profile Contacts & Feedback Help Configure the Catalyst Express 500 Switch with Cisco Network Assistant Home > Work With My Switches > Cisco Catalyst Switches > Configure

More information

Configuring VLANs. Understanding VLANs CHAPTER

Configuring VLANs. Understanding VLANs CHAPTER CHAPTER 16 This chapter describes how to configure normal-range VLANs (VLAN IDs 1 to 1005) and extended-range VLANs (VLAN IDs 1006 to 4094) on your Catalyst 2950 or Catalyst 2955 switch. It includes information

More information