Introduction. The Path Advantage
|
|
- April Atkinson
- 6 years ago
- Views:
Transcription
1 Table Of Contents Introduction... 1 The Path Advantage... 1 Communication Paths... 2 SCS-1R... 2 SCS-VR... 2 Path Groups... 3 Adaptive Technology... 3 Advanced Communication Programming.3 Understanding Paths... 3 Scenario One - Supervised Network with Adaptive Cellular Backup using one SCS-104 Network Line... 4 Scenario Two - Supervised Network with Cellular Backup using Two SCS-104 Network Line s... 5 Scenario Three - Supervised Network with Cellular Backup using two SCS-1R Central Station s... 6 Scenario Four - Supervised Network with Dual Supervised Primary Paths... 7 Scenario Five - Basic Dialer... 9 Scenario Six - Supervised Network with Adaptive Cellular Backup using SCS-VR Virtual Introduction This document describes how to take advantage of the programming options for communication using the XR100/XR500 and Series panels and provides examples of real-world communication techniques. The Path Advantage A path is the programming option used to determine the routing and conditions needed to send a message to the Central Station. Up to eight paths of communication may be programmed. There are two types of paths to choose from, a Primary path and a Backup path. The Primary path is the first path used to send messages. A Backup path is used if the preceding Primary path becomes unavailable. Once you have chosen the type for the path, the rest is easily configured from there. Paths of communication offer a significant advantage because a panel may be programmed with multiple Primary paths each with their own Backup path. Programming each individual path from beginning to end allows you to visualize how the messages are routed and handled. DMP Communication Options
2 J6 Interface Expansion Connector RESET DC 3.3V POWER ACK MESSAGE ACK ABC DEF GHI JKL M PQR STU VWX YZ COMMAND Communication Paths SCS-1R The example system shown below uses three communication paths. Path 1 is Primary and sends messages to the using communication. Path 2 is a Backup path that sends messages using CELL if the Primary path should be unavailable. Path 3 is also a Backup DD path that is only used if both paths 1 and 2 cannot successfully communicate messages. Another Backup path could also be programmed to send duplicate alarms to a different SCS-1R. Path 1 Communication path using Network () Communication path using Cellular (CELL) Internet Premises Path 2 SCS-1R Central Station SCS-1R Path 3 Communication path using Digital Dialer (DD) Host Automation SCS-VR The example system shown below uses two communication paths. Path 1 is Primary and sends messages to the SCS-VR Central Station using communication. Path 2 is a Backup path that sends messages using CELL if the Primary path should be unavailable. Local Network Computer LAN Connection SCS-VR Primary Computer* To Network Router Path 1 Path 2 Public Network Network Router WAN LAN4 LAN3 LAN2 LAN1 SCS-VR Backup Computer* To 120 VAC 60 Hz CELL To 120 VAC 60 Hz 12 VDC Battery
3 Path Groups A path group is made up of the Primary path and its subsequent Backup paths. Each Primary path establishes a new path group. Communication takes place on the Primary path with Backup paths being used only when the primary path fails or when the Backup path is programmed to duplicate alarm messages. Path groups are determined by path order, there is no need for a separate programming option to indicate a group. This is illustrated by the following programming scenario: Path 1 is Primary and path 2 is Backup, while Path 3 is Primary and paths 4-8 are Backup. There are therefore two Path Groups: The first Path Group consisting of paths 1 and 2, and The second Path Group consisting of paths 3-8. Adaptive Technology Adaptive Technology allows a Backup communication path programmed to use Network or Cellular to automatically ADAPT to the faster check-in rate of the Primary path should the Primary path become unavailable, creating a seamless transition for communication of messages. Select Adapt when programming the Checkin option. This allows a system to be fully supervised even if a path fails, while also keeping wireless charges low when the network is good. Advanced Communication Programming The Advanced Communication section combines options that are not used as often into one area such as Substitution Code and Alarm Reports. Advanced Communication programming also allows you to split out FIRE Alarm Messages, FIRE Supv/Trbl Messages, and Door Access Denied messages and send them to separate receivers. Understanding Paths To help you better understand the flexibility of paths, we have provided several scenarios on the next few pages that show different types of systems and the options programmed to meet the application. 3
4 J6 Interface Expansion Connector Scenario One - Supervised Network with Adaptive Cellular Backup using one SCS-104 Network Line The following example shows a Primary path programmed for supervised Network () communication with Cellular (CELL) Backup that adapts to the supervision checkin rate of the Primary path when it fails. Both paths are programmed to communicate to the same SCS-104 Network Line. By programming both paths to use the same SCS-104, it allows the Substitution Code and Adaptive Checkin messages to switch seamlessly from Primary to Backup. Path 1: Primary path using Network communication ADVANCED COMM TYPE PROTOCOL TCP PATH TYPE PRIMARY RETRY SECONDS 6 TEST REPORT YES SUB CODE YES (optional) Supervises TEST FREQUENCY 1 DAY this path ALARM REPORTS YES TEST TIME 3:45 AM SUPV/TRBL REPORTS YES CHECKIN YES O/C & USER YES CHECKIN MINUTES 3 DOOR ACCESS DENY Address for SCS-104 FAIL TIME 6 SEND COMM TRBL YES Network Line RECEIVER IP Path 2: ADVANCED COMM TYPE CELL APN SECURECOM PATH TYPE BACKUP Send daily SUB CODE SHARED TEST REPORT YES test report to SEND COMM TRBL YES TEST FREQUENCY 1 DAY verify CELL TEST TIME 3:45 AM path is good CHECKIN ADPT RECEIVER IP Same as Path 1 address for SCS-104 Network Line Adaptive path using Cellular communication Adapts to Path 1 check-in rate if Path 1 fails Uses the same substitution code as Path 1 CELL Internet Path 1 and Path 2 must report to the same SCS-104 Network Line 4
5 Scenario Two - Supervised Network with Cellular Backup using Two SCS-104 Network Line s The following example shows a Primary path programmed for supervised Network () communication with Cellular (CELL) Backup. Each path is programmed to communicate to different SCS-104 Network Line s in the same. By programming the paths to use different SCS-104, Host Automation software should be configured to look for a test report from Path 2 every hour after receiving a Not Responding (S16) message for Path 1. Primary path using Path 1: Network communication ADVANCED COMM TYPE PROTOCOL TCP PATH TYPE PRIMARY RETRY SECONDS 6 TEST REPORT YES SUB CODE YES (optional) TEST FREQUENCY 1 DAY Test Report SEND COMM TRBL YES to Automation TEST TIME 3:45 AM CHECKIN YES CHECKIN MINUTES 3 FAIL TIME 6 Address for SCS-104 Network Line RECEIVER IP Backup path Path 2: using Cellular ADVANCED COMM TYPE CELL communication APN SECURECOM PATH TYPE BACKUP FAIL TEST HOURS 1 TEST REPORT YES SUB CODE TEST FREQUENCY 1 DAY Send daily SEND COMM TRBL YES test report to TEST TIME 3:45 AM verify CELL CHECKIN path is good RECEIVER IP Path 2 address for different SCS-104 Network Line Checkins are never sent over CELL Tests this path hourly if Primary fails No substitution code used in this scenario CELL Internet Path 1 and Path 2 report to different SCS-104 Network Line s Host Automation 5
6 J6 Interface Expansion Connector Scenario Three - Supervised Network with Cellular Backup using two s The following example shows a Primary path programmed for supervised Network () communication with Cellular (CELL) Backup. Each path is programmed to communicate to SCS-104 Network Line s in different SCS-1R Central Station s. By programming the paths to use different SCS-1R s, Host Automation software should be configured to look for a test report from Path 2 (CELL) on the second receiver every hour after receiving a Not Responding (S16) message for Path 1 on the first receiver. Path 1: Primary path using ADVANCED COMM TYPE Network PROTOCOL TCP PATH TYPE PRIMARY communication RETRY SECONDS 6 TEST REPORT YES SUB CODE TEST FREQUENCY 1 DAY SEND COMM TRBL YES TEST TIME 3:45 AM CHECKIN YES CHECKIN MINUTES 3 Address for first SCS-1R FAIL TIME 6 Central Station Tests this path hourly if RECEIVER IP Primary fails Path 2: Backup path using Cellular ADVANCED COMM TYPE CELL communication APN SECURECOM PATH TYPE BACKUP FAIL TEST HOURS 1 TEST REPORT YES SUB CODE Send daily TEST FREQUENCY 1 test report to SEND COMM TRBL YES TEST TIME 3:45 AM verify CELL CHECKIN path is good RECEIVER IP Address for second SCS-1R Central Station Checkins are never sent over CELL No substitution code used in this scenario Path 1 and Path 2 report to different SCS-1R s in the same building Internet Host Automation CELL 6
7 Scenario Four - Supervised Network with Dual Supervised Primary Paths The following example shows two Primary paths programmed for supervised Network () communication. The second path has Digital Dialer (DD) backup. Each Primary path is programmed to communicate to SCS-104 Network Line s in different s. Primary path using Path 1: Network communication ADVANCED COMM TYPE PROTOCOL TCP PATH TYPE PRIMARY RETRY SECONDS 6 TEST REPORT YES SUB CODE YES (optional) TEST FREQUENCY 1 DAY ALARM REPORTS YES TEST TIME 3:45 AM SUPV/TRBL REPORTS YES CHECKIN YES O/C & USER YES CHECKIN MINUTES 3 DOOR ACCESS FAIL TIME 6 SEND COMM TRBL YES RECEIVER IP Address for first SCS-1R Central Station Path 2: Duplicate Primary path using ADVANCED COMM TYPE Network PROTOCOL TCP PATH TYPE PRIMARY communication RETRY SECONDS 6 TEST REPORT YES SUB CODE YES (optional) TEST FREQUENCY 1 DAY ALARM REPORTS YES TEST TIME 3:45 AM Supervises SUPV/TRBL REPORTS YES CHECKIN YES second path O/C & USER YES CHECKIN MINUTES 3 DOOR ACCESS FAIL TIME 6 SEND COMM TRBL YES RECEIVER IP Address for second SCS-1R Path 3: Central Station ADVANCED COMM TYPE DD FAIL TEST HOURS 1 Backup path PATH TYPE BACKUP 893A using TEST REPORT YES ALARM SWITCHOVER Digital Dialer TEST FREQUENCY 1 DAY DUPLICATE ALARMS communication TEST TIME 3:45 AM SEND COMM TRBL YES 1ST PHONE NUMBER ND PHONE NUMBER Phone numbers for SCS-1R Central Station One phone line used 7
8 J6 Interface Expansion Connector Path 1 and Path 2 Primary paths report to different SCS-1R s Internet Path 1 Host Automation Path 2 Path 3 DD Path 3 Backup for Path 2 8
9 J6 Interface Expansion Connector Scenario Five - Basic Dialer The following example shows a Primary path programmed for supervised Digital Dialer (DD) communication with an 893A. The path is programmed to communicate to the same using two different phone lines. By programming the path to use DD, the panel dials the 1st phone number two times, then dials the second phone number two times. The panel continues to alternate between the two programmed phone numbers until the ten dialed attempts have been made. Path 1: ADVANCED COMM TYPE DD 893A YES PATH TYPE PRIMARY ALARM REPORTS YES TEST REPORT YES SUPV/TRBL REPORTS YES TEST FREQUENCY 1 DAY O/C & USER YES TEST TIME 3:45 AM DOOR ACCESS DENY 1ST PHONE NUMBER SEND COMM TRBL YES 2ND PHONE NUMBER A used for two phone lines Host Automation PANEL 893A Dual Phone Line Module J2 F2 F1 J1 K1 P10 J4 J5 P3 + MAIN BACKUP K2 DS1 Path 1 with two phone lines 9
10 J6 Interface Expansion Connector RESET DC 3.3V WAN LAN4 LAN3 LAN2 LAN1 Scenario Six - Supervised Network with Adaptive Cellular Backup using SCS-VR Virtual The following example shows a Primary path programmed for supervised Network () communication with Cellular (CELL) Backup that adapts to the supervision checkin rate of the Primary path when it fails. Both paths are programmed to communicate to the consist of two completely duplicated computers running SCS-VR and designated as SCS-VR Primary and SCS-VR Backup. Path 1: Primary path using Network communication ADVANCED COMM TYPE PROTOCOL TCP PATH TYPE PRIMARY RETRY SECONDS 6 TEST REPORT YES SUB CODE YES (optional) TEST FREQUENCY 1 DAY ALARM REPORTS YES Supervises TEST TIME 3:45 AM SUPV/TRBL REPORTS YES this path CHECKIN YES O/C & USER YES CHECKIN MINUTES 3 DOOR ACCESS DENY FAIL TIME 6 SEND COMM TRBL YES Address for SCS-VR RECEIVER IP Path 2: ADVANCED COMM TYPE CELL communication APN SECURECOM PATH TYPE BACKUP SUB CODE SHARED TEST REPORT YES Send daily test SEND COMM TRBL YES TEST FREQUENCY 1 DAY TEST TIME 3:45 AM CHECKIN ADPT RECEIVER IP Adaptive path using Cellular report to verify CELL path is good Adapts to Path 1 check-in rate if Path 1 fails Uses the same substitution code as Path 1 Same as Path 1 address for SCS-VR Computer LAN Connection Local Network SCS-VR Primary Computer* To Network Router Path 1 Path 2 Public Network Network Router SCS-VR Backup Computer* To 120 VAC 60 Hz CELL To 120 VAC 60 Hz 12 VDC Battery 10
11 11
12 Designed, Engineered and Assembled in USA INTRUSION FIRE ACCESS WORKS 2500 North Partnership Boulevard Springfield, Missouri LT , Inc
XR500/XR100 Command Processor Review. a) Zone expanders c) Output expanders b) All of these d) Single point detectors
Name Answer Key Company Address City, State, Zip Instructor Date Your email User Name = Password = XR500/XR100 Command Processor Review 1. may be connected to the LX-Bus. a) Zone expanders c) Output expanders
More informationXT30/XT50 PROGRAMMING PART 1. Slide 1. Slide 2. Slide 3. Objectives. XT30/XT50 Basic Training Programming- Part 1. Accessing the Programmer
Slide 1 XT30/XT50 Basic Training Programming- Part 1 Slide 2 Objectives After completing this course you will: 1) Understand how to prepare the panel for programming and how to access the built-in programmer.
More informationepad 5.0 Mobile Keypad
Programming Guide epad 5.0 Mobile Keypad Description Providing much-needed flexibility, the epad 5.0 Mobile Keypad allows users to control their DMP security system using an Internet browser. The epad
More informationHOW-TO GUIDE: MANAGING CREDENTIALS
HOW-TO GUIDE: MANAGING CREDENTIALS LT-1633 17185 ADD A CREDENTIAL Follow these steps to add a new personnel record credential. 1 Open the Management menu and select Personnel. 2 Open the Add drop-down
More informationSILENCING AN ALARM. When the alarm bell or siren is sounding, enter your user code or present your keyfob to your keypad.
S Y S T E M U S E R G U I D E SILENCING AN ALARM When the alarm bell or siren is sounding, enter your user code or present your keyfob to your keypad. IS THIS A FALSE ALARM? YES NO displays. REAL ALARM
More informationXT30/XT50 OVERVIEW. Slide 1. Slide 2. Slide 3. Objectives. XT30/XT50 Basic Training System Overview. XT30/XT50 Description
Slide 1 XT30/XT50 Basic Training System Overview Slide 2 Objectives After completing this course you will be able to: 1) Understand the basic features of the panel. 2) Understand the different modes of
More information1101 Universal Transmitter
INSTALLATION SHEET 1101 Universal Description The 1101 is a two input transmitter that is typically used for door/window applications. The 1101 provides two internal magnetic reed switches and an on-board
More information7760 LCD Glass Keypad
* * * INSTALLATION GUIDE 7760 LCD Glass Keypad Description The DMP Model 7760 LCD Glass Keypad offers the same functionality and flexible features as standard DMP keypads. The contemporary glass touch
More informationeurösec CPX Control Panel User Instructions
eurösec CPX Control Panel User Instructions eurösec CPX User Manual Contents User Information... 2 Introduction... 3 User Code Types... 3 Setting The System... 4 Setting & Unsetting via Keyswitch... 4
More informationOperating & ProgrammingGuide
LCD Keypad Operating & ProgrammingGuide Arrowhead Alarm Products Ltd VERSION 2.03 Proudly Designed and Manufactured in New Zealand 1 CONTENTS Page No. INTRODUCTION 3 Introduction to the LCD Keypad 3 KEYPAD
More informationConversion of Contact ID event codes sent by alarm control panel via GSM and PSTN channel to SMS messages
GSM ProCom Description GSM and PSTN communication Management of 2 independent SIM cards Reception of incoming calls, possibility for restriction Installable behind PBX Management of different prefix numbers
More informationnetwork M O N I T O R I N G
network M O N I T O R I N G NETWORK MONITORING A DMP first. The industry s best. In the early 1980 s, while the industry struggled with the limitations of pulsed analog communication formats, the founder
More informationC900V2 Selling Strategy Guide
Tom Mechler Product Marketing Manager, Intrusion Bosch Security Systems, Inc. (585) 340-4145, Tom.Mechler@us.bosch.com Page 1 of 8 A Word About This Guide This Selling Strategy Guide is designed to help
More information*00 INSTALLER CODE Enter 4 digits, 0-9 [4140] *28 POWER UP IN PREVIOUS STATE [1=yes] 0=no; "1" for UL.
4140XMPT2 PROGRAMMING FORM Some fields are programmed for each partition (shown as shaded fields). See the PARTITION-SPECIFIC section for programming these fields. Standard default (*97) values are shown
More informationVISTA-128BP/VISTA-250BP Programming Form
VISTA-128BP/VISTA-250BP Programming Form Some fields are programmed for each partition (shown as shaded fields). If you are programming a multiple-partition system, see the Partition-Specific Fields section
More informationKarizma PlusTM. Intruder alarm system Operating instructions. Introduction
Karizma PlusTM Intruder alarm system Operating instructions Introduction The purpose of this user guide is to describe how to operate Karizma plus system. Some of the features described in this guide may
More informationContents. Introduction Full Setting the System Part Setting the System (using Part 1)... 2
TM C P 8 L L C D U S E R M A N UA L TM Contents Introduction............................ 1 Full Setting the System.................... 1 Part Setting the System (using Part 1)........ 2 Part Setting the
More informationAC5160 SiPass integrated controller kit
AC5160 SiPass integrated controller kit SiPass integrated Wall housing with pre-assembled basic SiPass integrated components Equipped with one ACC (AC5100), two dual reader interfaces (ADD5100) and one
More informationTPNA-1000 Triple Play Network Analyzer
TPNA-1000 Triple Play Network Analyzer Section I: The Basics 1.1 1.2 THIS PAGE LEFT INTENTIONALLY BLANK Chapter 1 1. General Information Helpful Website The following website contains general information
More informationControl Panel D9112. Release Notes for Version 7.00 March Introduction. 2.0 Requirements. 4.0 Previous Version 6.
Control Panel D9112 Release for Version 7.00 March 2007 1.0 Introduction Although the D9112 (expanded version) Control Panel is no longer manufactured (replaced by the D9412G), Firmware Update Kits (P/N:
More informationACX Series. Access Controller for Ethernet
Access Controller for Ethernet The controllers are the industry s most powerful all-in-one access controllers designed for both critical government and private sector security applications. 0 Features
More informationPS-4100 POWER SUPPLY MANUAL
PS-4100 POWER SUPPLY MANUAL Manual Part Number 180-0573 December 7, 2006 TABLE OF CONTENTS TITLE PAGE Table of Contents... 2 List Of Figures... 3 1. Introduction... 4 1.0. General... 4 1.1. Features...
More informationSpectraComm Quick Reference
SpectraComm Quick Reference Highlights High Density Low Power NEBS 3 Certified Managed Steadfast Security Flexible Introduction General DataComm s SpectraComm family of modems, CSU/DSUs and LAN products
More informationControl Panel D9124. Release Notes for Version 7.00 March Introduction. 2.0 Requirements. 4.0 Previous Version 6.
Control Panel Release for Version 7.00 March 2007 1.0 Introduction Firmware Update Kits (P/N: D9499-0700) are available for this product. Refer to the D9412G/D7412G Program Entry Guide (P/N: 47775D or
More informationHost Communication Specification
Host Communication Specification SCS-1R Receiver Using SCS-150 Processor Version 104 (12/14/17) or SCS-VR Version 1.4.0 (3/31/17) LT-0872.pdf (Jan 22, 2018) http://buy.dmp.com/dmp/products/documents/lt-0872.pdf
More informationEA500. Installation Instructions Transponder
EA500 EN Installation Instructions Transponder EA500 Installation Instructions 1.0 Overview EN 2 1.0 Overview The EA500 Transponder is the Security Escort module that provides communications between the
More informationSYMMETRY MULTINODE M2150 INTELLIGENT CONTROLLER
MULTINODE M2150 MULTINODE M2150 INTELLIGENT CONTROLLER The multinode M2150 range of controllers provides distributed intelligence for your access control system and ensures complete system security, resilience
More informationTechnical Specification H8922 3G/4G Router
www.hongdian.com Technical Specification H8922 3G/4G Router H8922 3G/4G Router Technical Specification Contents Contents...i 1 Product Overview...3 2 Product Specification...3 3 Definition of Structure
More information6 Cell 180 Cell 244 Cell 589 Cell 246 Cell 400 Cell 24 Cell 52 Cell 5 Set 4 Unit (contact CIF) 15 Piece Carrier relay multiplex converter
The main procurement plan in fiscal 2018 *We are considering implementation methods and timing aiming for thorough efficiency improvement. Long life control valve type storage battery 40Ah 2V 1cell 6 Cell
More informationmultinode M2150 INTELLIGENT CONTROLLERS
multinode M2150 INTELLIGENT CONTROLLERS SYSTEMS ACCESS CONTROL KEY FEATURES: - Modular mix and match configuration - Connects to Symmetry management software via LAN, WAN, RS232 or Modem - Each M2150 can
More informationAV-4000 GSM AV-4000 DVR
E a s y L o a d e r AV-4000 GSM AV-4000 DVR (for LED keypads) Integrated Alarm Control panel & Communicator Series 4000 Appendix for GSM Alarm Panels Version 1.05 Edition I This product is subject to continuous
More informationInet Comms Task Format
11. Inet Comms-11-1 Inet Comms Task Format Purpose. The purpose of the Inet Comms Task is to allow multiple panels to communicate alarm data and a limited amount of database editing commands to and from
More informationInstallatIon GuIde scs-1r security ContRol ReCeIveR DMP Receiver Help Line
Installation Guide SCS-1R Security Control Receiver DMP Receiver Help Line Technical Service 1-888-436-7832 International 1-417-831-9362 After hours receiver emergencies 1-417-831-2866 Security Control
More informationVisorALARM-Manager Application Quick Guide. (Ver. 1.3) Dm 380-I. V:3.0
VisorALARM-Manager Application Quick Guide. (Ver. 1.3) Dm 380-I. V:3.0 1. Installation Requirements 1.1. PC Pentium III processor or higher. Minimum RAM memory: 128 Mbytes Operating system: Windows XP
More informationFPD-7024 Fire Alarm Control Panel Version 1.03
FPD-7024 Fire Alarm Control Panel Version 1.03 Program Record Sheet Account Information: Account: Date: Name: Address: Panel Phone #: Contact Phone #: Contact Person: Comments: Panel Location: Notes: Program
More informationPegasus HC Lighting Control Panel
Overview The drives up to 32 relays, each rated 20 amps, with an integrated time clock and photocell input. Users can manually switch outputs on or off from a remote pushbutton controller, or create time
More informationFSK TX CELLULAR PLUS. Installation and Programming Guide. Tel:
FSK TX CELLULAR PLUS Installation and Programming Guide Tel: 0861 105 962 www.fsk.co.za INTRODUCTION The FSK TX Cellular Plus (TXC+) is a highly featured GSM based unit which is used for the transmission
More informationINSTALLATION SHEET 791 and 793 Easy Entry Keypads
INSTALLATION SHEET 791 and 793 Easy Entry Keypads Description The DMP 791 and 793 Easy Entry LCD Keypads are the industry s first burglary/fire keypads with integrated access control capability. Each keypad
More informationTDSi EXpert type door controllers offer a fully featured door controller with up to 48,000 card memory.
1 EXpert Based Access Control System - Overview TDSi EXpert type door controllers offer a fully featured door controller with up to 48,000 card memory. EXpert2 is capable of controlling 2 doors with the
More informationGC-101 GPS / GSM Micro Tracker
GC-101 GPS / GSM Micro Tracker Table of Contents 1. Hardware Description...4 1.1 Front Face...4 1.2 Side Face...4 1.3 Bottom Face...6 1.4 Charging...6 1.5 Rear Face (Battery Cap)...7 2. Specifications...8
More informationETM350C & ETM450C User Manual
Industrial Ethernet Router ETM350C & ETM450C User Manual Features ETM350C // ETM450C: HSDPA/UMTS 850/900/2100MHz // 850/900/1900/2100MHz GSM/GPRS 900/1800MHz // 850/900/1800/1900MHz HSUPA 14.4Mbps DL,
More informationDate of circulation /647/MCR. Safety EMC Environment Quality assurance
IEC/TC or SC: TC 57 Title of TC/SC: Power system control and associated communications Also of interest to the following committees Project number IEC 60870-5-104 Amed. 1 Ed.1 Date of circulation 2003-08-15
More informationPRODUCT BRIEF. Metroplex Super Intelligent Access
PRODUCT BRIEF Metroplex 6000 Super Intelligent Access Overview Many customer applications have migrated from centralized mainframes to the PC. Local Area Networks are now primary conveyors of data within
More information1 Description. 2 Specifications. Product Installation Document. Honeywell 12 Clintonville Road Northford, CT
Honeywell 12 Clintonville Road Northford, CT 06472 http://www.honeywellpower.com HP600ULACM4CB HP600ULACM8CB Access Control Power Supply/Charger with Power Distribution Controller PN 52395:A 1/05/06 ECN
More informationSOFTWARE VERSION 3.10
738PEP-03 SOFTWARE VERSION 3.10 HEXA PROGRAMMING: Addresses 000 to 043 and 300 to 527 are programmed using the Hexa Programming method. In this mode, you can enter any hexa-digit from 0-F where keys [1]
More informationVISTA-50P VISTA-50PUL
VISTA-50P VISTA-50PUL PARTITIONED SECURITY SYSTEM with SCHEDULING Quick Start Step-by-Step Programming Procedure Single And Multiple Partition Programming Forms System Worksheets VISTA50P-PR 8/95 (See
More informationTABLE OF CONTENTS. Notice...i How to Use This Program Entry Guide...i About the Type Styles That We Use in the Text...i D5200 Key Descriptions...
TABLE OF CONTENTS Notice...i How to Use This Program Entry Guide...i About the Type Styles That We Use in the Text...i D5200 Key Descriptions...ii PROGRAMMING THE D6500...1 LINE CARD Create Custom Programs
More informationHWUTES186/01436n (10 pages) PROCESSOR & PERIPHERAL BOARD TESTING
80186 PROCESSOR & PERIPHERAL BOARD TESTING SUBJECT: MILNOR Micro-Processor and Peripheral Board Testing Procedures Using 80186 Processor and Serial Display This procedure will allow testing of the 186
More informationProduct Overview. Switch Model CHAPTER
CHAPTER The Catalyst 3560-C and 2960-C of switches, also referred to as the switch, are Ethernet switches to which you can connect devices such as Cisco IP Phones, Cisco Wireless Access Points, workstations,
More informationTechnical Specification H8922S 3G/4G Router
www.hongdian.com Technical Specification H8922S 3G/4G Router Contents 1. Product Overview... 2 2. Product Specification... 2 3. Definition of Structure Size and Interface... 3 4. Panel Indicator Status...
More informationINPUTS: Are 10K end of line monitored, with a response time of 300 ms. Alarm triggers SIREN, STROBE and REPORTING (depending on setup)
INPUTS: All inputs: Inputs 1 to 24: Tamper: Panic: Fire: Keyswitch: 16-18VAC: Are 10K end of line monitored, with a response time of 300 ms. Alarm triggers SIREN, STROBE and REPORTING (depending on setup)
More informationKilomux-2100/2104. Data, Voice, Fax and LAN Integrating Modular Multiplexer FEATURES
-2100/2104,, and LAN Integrating Modular Multiplexer FEATURES Modular integrating access multiplexer for data, voice, fax and LAN Advanced voice compression techniques maximize utilization of main link
More informationPCR43304R, PCR43304RE 4-Channel, 433MHz Penta Receiver with Frequency Hopping
PCR43304R, PCR43304RE 4-Channel, 433MHz Penta Receiver with Frequency Hopping Features Frequency hopping between 433.10 to 434.70MHz 12-way dipswitch or encrypted coding Momentary and latching modes are
More information4140XMPT2 PROGRAMMING FORM
414XMPT2 PROGRAMMING FORM Some fields are programmed for each partition (shown as shaded fields). See the PARTITION-SPECIFIC section for programming these fields. Standard default (*97) values are shown
More informationConnecting a Cisco Input Module
CHAPTER 4 Overview The optional Cisco Input Module (Figure 4-1) is attached to a Cisco Physical Access Gateway or Cisco Reader Module to provide additional connections for up to ten input devices. Each
More information1HWZRU;1;( Table of Contents. General Description...2. Ordering Information...2. Feature Definitions...3. Programming the LED Keypads...
HWZRU;;( Control/Communicator Installation Manual Table of Contents General Description... Ordering Information... Feature Definitions... Programming the LED Keypads... Programming the NX-E...9 Types of
More informationQuick Installation Guide
Quick Installation Guide 4G Mobile Router & Access Point 150 Mbps Wireless-N w/ USB port HN-MRN1U Version 1.00 (June 12) Package Contents HN-MRN1U with battery USB Power Cable USB/RJ-45 LAN Cable Quick
More informationPCR43304R, PCR43304RE 4-Channel, 433MHz Penta Receiver with Frequency Hopping
PCR43304R, PCR43304RE 4-Channel, 433MHz Penta Receiver with Frequency Hopping Features Frequency hopping between 433.10 to 434.70MHz 12-way dipswitch or encrypted coding Momentary and latching modes are
More informationex 800A Series ematrix System
The is a fully integrated and versatile public address system which is designed distinctively to fulfill the demands for both emergency and communication broadcasting. The operates normally as a Public
More informationSMS525 Communicator. Quick Start Guide
SMS525 Communicator SIGNAL FOX GSM52S 2 STAT Quick Start Guide CONTENTS ) Card Setup 2) Communicator to Panel Connection 3) Communicator Start Up 4) Important Notes for SMS Commands. 5) Master User Setup
More information9800 Series Wireless Graphic Touchscreen Keypad
INSTALLATION GUIDE 9800 Series Wireless Graphic Touchscreen Keypad TODAY CURRENT 82 HI LO 98 77 WEDNESDAY HI LO 98 77 2017 Digital Monitoring Products, Inc. Information furnished by DMP is believed to
More informationLab 5: Access Control Training Station
Lab 5: Access Control Training Station Learning Objectives At the end of the lab, trainees should be able to: 1. Understand the functional block and hardware of an access control system. 2. Understand
More informationPCS200 GPRS Communicator Module V1.0
PCS200 GPRS Communicator Module V1.0 Installation and User Manual Warranty For complete warranty information on this product please refer to the Limited Warranty Statement found on the website www.paradox.com/
More informationCisco CRS 16-Slot Chassis Power Systems
This chapter includes the following sections: Power specifications are provided in Technical Specifications Power Systems Overview, on page 1 Power Component Information Common to the Two Types of Power
More informationEC-11 Ethernet Converter
EC-11 Ethernet Converter PSTN Contact ID to TCP Converter Installation and Operations Manual Version 8.H3.MID 1 Table of Contents About EC-11 Ethernet Converter... 3 Circuit Board Layout and Wiring Diagram...
More informationcontroller data sheet JACE 8000 PRODUCT DEFINITION HARDWARE SPECIFICATIONS
data sheet JACE 8000 controller PRODUCT DEFINITION The JACE 8000 is a compact, embedded IoT (Internet of Things) controller and server platform for connecting multiple and diverse devices and sub-systems.
More informationTAS-2000 SERIES. ADC Telephone Access System. User s Guide. LT-884 Rev. 0 April 2005
Advanced Life Safety Solutions TAS-2000 SERIES ADC Telephone Access System 3 4 7 5 8 9 0 3 4 7 5 8 9 0 User s Guide LT-884 Rev. 0 April 2005 TAS-2000 ADC System User s Guide Contents Introduction... 1
More informationSEL-487B. A Powerful Solution for Busbar Differential Protection. Bus Differential and Breaker Failure Relay
Bus Differential and Breaker Failure Relay A Powerful Solution for Busbar Differential Protection Features and Benefits Select the for the differential protection of busbar systems with up to 18 terminals.
More information3x16 Display. AUX Lamp. Interactive Soft-Keys Navigation Keys. Speaker Key. Microphone. Omega-Phone OM-KTD30 Digital Telephone
INTRODUCTION 3x16 Display AUX Lamp Interactive Soft-Keys Navigation Keys Headset Jack Programmable Feature Keys Speaker Key Microphone Omega-Phone OM-KTD30 Digital Telephone This guide describes basic
More informationMCImetro Access Transmission Services Corp. MARYLAND P.S.C. TARIFF NO. 3 d/b/a Verizon Access Transmission Services ORIGINAL PAGE NO.
d/b/a Verizon Access Transmission Services ORIGINAL PAGE NO. 46 5. SWITCHED ACCESS SERVICE 5.1 General Access Services Switched Access Service, which is available to Customers for their use in furnishing
More informationIntrusion Control Panels Quick Guide. May 2015
Intrusion Control Panels Quick Guide May 2015 Control Panels B Series Commercial Type Number B3512 B4512 B5512 Applications Type Residential, Small Commercial Residential, Small Commercial Residential,
More information4CH MOBILE DVR OPERATING INSTRUCTIONS
4CH MOBILE DVR OPERATING INSTRUCTIONS Before operating this set, please read these instructions completely The DVR needs to use SD card from Brand SAN DISK, the reading and Writing speed needs to reach
More informationDell Docking Family Brochure
Dell Docking Family Brochure Transition seamlessly and quickly to productivity. Introducing the most complete portfolio of Dell docking solutions. Designed to efficiently connect to displays, keyboards,
More informationAP038 Instructions & Guarantee
AP038 Instructions & Guarantee INTERNET BASED 4-DAY FORECAST WEATHER STATION Owner s Manual Thank you for purchasing the new generation of our Internet based 4-day forecast weather station. Designed and
More informationNetwork Infrastructure, Desktop, and Server Support Service Level Agreement
Network Infrastructure, Desktop, and Server Support Service Level Agreement INTRODUCTION This service level agreement ( SLA ) describes the core services provided to customers by Micro- Management Systems,
More informationDelivered the Way Yo u Want
SENSAPHONE IMS-4000 Infrastructure Monitoring System Mo nito r What Yo u Want Delivered the Way Yo u Want THE SENSAPHONE IMS-4000 MONITORS AND REPORTS THE INFORMATION THAT YOU NEED TO KNOW: Get critical
More informationSettings Settings
... 2 Overview... 2 WLAN & WAN Information... 3 Advanced... 4 Changing Security... 20 Internet Connectivity... 21 Overview Activating SoftBank 007Z Utility Use SoftBank 007Z Utility to change network settings,
More informationGPRS ADAPTER INSTALLATION AND USER MANUAL. for module version v2.24 and higher
GPRS ADAPTER INSTALLATION AND USER MANUAL for module version v2.24 and higher Table of contents 1 Main function of the Adapter...3 2 System operation...3 2.1 Transmission through GPRS...4 2.1.1 Router
More information1500ct Pump Controller
Quality Control & Integration, Inc. Control, Instrumentation, Telemetry, SCADA, and Automation Systems 1500ct Pump Controller Dynamic Solutions for greater control and true dynamic I/O, color, touch screen
More information1500ct Pump Controller
Quality Control & Integration, Inc. Control, Instrumentation, Telemetry, SCADA, and Automation Systems 1500ct Pump Controller Dynamic Solutions for greater control and true dynamic I/O, color, touch screen
More informationEaton DC Power Solutions
Eaton DC Power Solutions 19 sub-rack Modular 3U and 6U options Up to 6 rectifier modules Pre-configured software High power density (24/48V: 300/250A, 6U, 19 ) Multiple AC option (1Ø, 3Ø, 2Ø) Fast on-line
More informationModel HM-535 Power Supply Installation and Service Instructions
Model HM-535 Power Supply Installation and Service Instructions 430-535 0104 2004 Heritage MedCall, Inc SENTRY INSTALLATION & SERVICE INSTRUCTIONS POWER SUPPLY UNIT Model HM-535 IMPORTANT SAFETY INSTRUCTIONS
More informationTOUCHLOCK compact. Ins-182 Date code:
TOUCHLOCK compact Ins-82 Date code: 0050 About TOUCHLOCK compact is a single door, single keypad access control system. The keypad is suitable for internal and sheltered external installations and for
More information8088 PROCESSOR & PERIPHERAL BOARD TESTING
HWUTEST88/01943n (10 pages) 8088 PROCESSOR & PERIPHERAL BOARD TESTING SUBJECT: MILNOR Micro-Processor and Peripheral Board Testing Procedures Using 8088 Processor and Parallel Display This procedure will
More informationNetAXS-123: One door, compact (plastic) enclosure. NetAXS-123: One door, standard (metal) enclosure with tamper switch and terminal block
Honeywell s web-based access control offering now provides solutions for installations of any size. NetAXS enables users to manage their system anywhere there s an Internet connection with no dedicated
More informationAndover ContinuumTM Infinet II
Andover ContinuumTM Infinet II The i80 Series controllers are designed for control of Air Handling Units, Roof Top Units, and other mechanical plant equipment. Features 0 Choose the i80 model with the
More informationKilomux-2100/2104. Data, Voice, Fax and LAN Integrating Modular Multiplexer FEATURES
Data, Voice, Fax and LAN Integrating Modular Multiplexer FEATURES Modular integrating access multiplexer for data, voice, fax and LAN Maximized utilization of main-link bandwidth and high quality low bit
More informationenetworks TM C2C Hardware Description and Specifications A.1 C2C Chassis Hardware Description
encor! enetworks TM Version A.1, January 2012 2012 Encore Networks, Inc. All rights reserved. C2C Hardware Description and Specifications This chapter provides information on the hardware for the C2C chassis.
More informationSecurity System. Owner s Manual
Security System Owner s Manual What You Need to Know Before using this manual, you should become familiar with the Security System User s Guide. The User s Guide provides step by step instructions for
More informationIndustrial Metering Unit-II/S (IMU-II/S) AC-Powered Unit Assembly with Serial Port and Control Output Option Mercury Instruments Stock #
Honeywell Process Solutions Industrial Metering Unit-II/S (IMU-II/S) AC-Powered Unit Assembly with Serial Port and Control Output Option Mercury Instruments Stock # 2001-0196-001 User Manual November 2010
More informationLifeLine Series. User Guide Px-100 Lifeline Paging Control Panel
Manual LifeLine Series User Guide Px-100 Lifeline Paging Control Panel The operation and functions described in this manual are available from Software Version Px100-001-01 onwards. 1 INTRODUCTION 1.1
More informationcontroller data sheet JACE 8000 PRODUCT DEFINITION HARDWARE SPECIFICATIONS
data sheet JACE 8000 controller PRODUCT DEFINITION The JACE 8000 is a compact, embedded IoT (Internet of Things) controller and server platform for connecting multiple and diverse devices and sub-systems.
More informationEarthLink Business SIP Trunking. Allworx 6x IP PBX SIP Proxy Customer Configuration Guide
EarthLink Business SIP Trunking Allworx 6x IP PBX SIP Proxy Customer Configuration Guide Publication History First Release: Version 1.0 August 30, 2011 CHANGE HISTORY Version Date Change Details Changed
More informationIntroduction. Basic Programming for CellComSLCF CID Dialer Capture Communication
APPLICAIO OE CellComLCF Cellular Communicator Dialer Capture Introduction... 1 asic Programming for CellComLCF CID Dialer Capture Communication... 1 Wiring Diagrams... Ademco Vista 18FP... Ademco Vista
More informationSC2000 MOTOR PROTECTION ELECTRONICS, INC. INSTRUCTION MANUAL. (407) Phone: Website:
SC2000 INSTRUCTION MANUAL MOTOR PROTECTION ELECTRONICS, INC. 2464 Vulcan Road Apopka, Florida 32703 Phone: Website: (407) 299-3825 www.mpelectronics.com Operating Program Revision: 12 Revision Date: 8-27-14
More informationDISPATCHABLE IRRIGATION LOAD CONTROL SYSTEM
DISPATCHABLE IRRIGATION LOAD CONTROL SYSTEM REMOTE MONITORING & CONTROL OF HIGH VOLTAGE PUMP & IRRIGATION SYSTEMS FOR THE PURPOSE OF ELECTRIC DEMAND SIDE MANAGEMENT OVERVIEW & HIGHLIGHTS Field tested,
More informationTLS-3XX Series Consoles
Manual No: 0-0 Revision: A TLS-XX Series Consoles Display Replacement Guide Notice Veeder-Root makes no warranty of any kind with regard to this publication, including, but not limited to, the implied
More informationRemote Programming Software LITE (RPS LITE)
Remote Programming Software LITE (RPS LITE) D5500CU LITE, v6.06.016 en Release Notes Remote Programming Software LITE (RPS-LITE) Introduction en 3 1 Introduction RPS-LITE version 6.06.016 Release Notes.
More informationTrueCom. Building Communications Systems 5110-Series Controllers. UL Listed. Features. Operation. Description
TrueCom UL Listed Building Communications Systems 5110-Series Controllers Features Cost-effective Solid State Intercom Expandable to 120 Points Privacy and Pre-Announce Tones are User Selectable Telephone
More informationTECHNICAL MANUAL NEW PANDINO 4. GSM Telephonics Communicator WITH QUAD-BAND GSM INDUSTRIAL MODULE
TECHNICAL MANUAL NEW PANDINO 4 GSM Telephonics Communicator WITH QUAD-BAND GSM INDUSTRIAL MODULE GSM TELEPHONE COMMUNICATOR IS IN CONFORMITY WITH ALL THE ESSENTIAL REQUIREMENT OF DIRECTIVE 1999/5/CE 89/336/CEE
More information