Installing And Programming The Analog Terminal Interface On The DXP, DXP Plus, and FX Series Digital Communications Systems
|
|
- Thomasine Harrison
- 6 years ago
- Views:
Transcription
1 R Installing And Programming The Analog Terminal Interface On The DXP, DXP Plus, and FX Series Digital Communications Systems The Analog Terminal Interface The ATI-D-1PT is a multipurpose, on-premise accessory for the digital communications system that enables you to connect IST devices to a digital station board. The ATI-D-1PT supports a wide variety of IST equipment such as 500 and 2500-type telephones, cordless telephones, answering machines, FAX machines, data modems, and analog voice mail systems. It will accept both tone (DTMF) and pulse (rotary) dialing from these devices. CAUTION The ATI-D-1PT by itself does not support any off-premise service. Never connect the ATI-D-1PT to a TELCO line unless you have installed an OPX long loop adapter. (Refer to the installation section of this document for OPX long loop adapter installation instructions.) The ATI-D-1PT unit contains an internal ring generator and telephone circuitry that supports one IST input. Modular connectors allow for quick hookup to the digital station port and the IST device(s). The ATI-D-1PT supports a maximum ringer equivalence number (REN) of 2.0, allowing it to support more than one IST device, if they are bridged. Check the REN number of the IST equipment you connect so as not to exceed the capacity of the ATI-D-1PT. This manual has been developed by Comdial Corporation (the Company ) and is intended for the use of its customers and service personnel. The information in this manual is subject to change without notice. While every effort has been made to eliminate errors, the Company disclaims liability for any difficulties arising from the interpretation of the information contained herein. The information contained herein does not purport to cover all details or variations in equipment or to provide for every possible contingency to be met in connection with installation, operation, or maintenance. Should further information be desired, or should particular problems arise which are not covered sufficiently for the purchaser s purposes, contact Comdial, Inside Sales Department, Charlottesville, Virginia Printed in U.S.A. IMI /98
2 IMI Installing And Programming The ATI-D-1PT Specifications Power Requirements Ringing voltage Battery Feed Voltage Loop current limits between ATI-D and IST interface DC loop limits from ATI-D to industry standard interface per port Cable insulation resistance ATI-D to common equipment cable requirement Cable terminations Dialing Electrical Specifications Supplied by the common equipment 55 VAC 20 Hz (45 VAC minimum) Power rated to maximum REN = VDC nominal 20 ma min. at 620 ohms (loop resistance + IST resistance) 70 ma max. at 0 ohms 620 ohms maximum, including interfaced telephony device (Approximately 4000 feet with #26 AWG twisted-pair cable and 300 ohm device load) (Approximately 500 feet if two IST devices are connected in parallel on same tip and ring pair) 30,000 ohms minimum 2-pair twisted cable; 25 feet maximum length. 623-type, 4-conductor minijacks Industry-standard DTMF or pulse (rotary) with nominal make/break ration of 10 PPS Operating temperature Humidity Environmental Specifications F (0 50 C) 0% to 90% relative, non-condensing 2 Installing The ATI-D-1PT
3 Installing And Programming The ATI-D-1PT IMI Height Width Length Weight Mechanical Specifications inches inches inches 4 lbs. (plus 2 lbsx for packing material) Industry/Regulatory Standards FCC registered and listed for safety compliance as part of digital communications system: FCC, Part 15 (class A), certified. FCC, Part 68, certified. UL 1459 certified. Installing The ATI-D-1PT 3
4 IMI Installing And Programming The ATI-D-1PT Mounting Considerations For The ATI-D-1PT 1. The distance between the ATI-D-1PT and the common equipment must be 25 feet or less. 2. You can mount the ATI-D-1PT to any sturdy, flat surface. 3. The mounting location must be secure and dry and have adequate ventilation. The temperature range of the location must be within F (0-50 C). 4. If the mounting surface is damp or if it is masonry material, you must use a backboard between the ATI-D-1PT and the mounting surface. 5. Tools and hardware required for mounting the ATI-D-1PT include: fasteners (wood screws 1/4 x 1-inch round head toggle bolts, or wall anchors), screwdriver, electric drill, connecting tool (for fastening wires to a type-66 connector block), crimping tool (for 623-type modular plugs). Mounting The Cabinet 1. Unpack and carefully inspect the ATI-D-1PT for shipping damage. Notify the shipper immediately of any damage found. Verify that the package contains all parts and accessories needed for proper installation and operation. 2. If you are using a backboard, attach it securely to provide a stable mounting surface. 3. Use the base of the ATI-D-1PT as a template to measure and mark mounting hole locations. 4. Drill holes in the mounting surface to attach the hardware being used. If necessary, prepare these holes with inserts, anchors, etc. 5. Insert the two top screws into the mounting surface and tighten them to within approximately 1/8-inch of the surface. 6. Hang the ATI-D-1PT on the top screws using the mounting holes located on the rear of the cabinet. 7. Insert a third screw through the mounting tab located on the lower edge of the cabinet and tighten it into place. 4 Installing The ATI-D-1PT
5 Installing And Programming The ATI-D-1PT IMI /16 5 5/ / / /8 Outline Dimensions (In Inches) Spacing For Mounting Hardware (In Inches) ATI-D-1PT Dimensions Installing The ATI-D-1PT 5
6 IMI Installing And Programming The ATI-D-1PT Connecting The Equipment Connect the cabling to the ATI-D-1PT as shown in the diagram on the next page. CAUTION Be careful when connecting the wiring between the common equipment and the ATI-D-1PT. Be sure to connect the digital station port to the COMMON EQUIPMENT (KSU) jack on the ATI-D-1PT. Damage to the ATI-D-1PT could occur if this wiring is connected to the IST jack. While a grounding wire is not required for operation, one is desirable for decreasing radio frequency interference and electrostatic discharge susceptibility. The ATI-D-1PT has a grounding stud for this purpose. Connect a #10 or #12, insulated, solid copper wire between this ground stud and an earth ground. Checking The Installation Use a voltmeter to check for the presence of voltage on the ATI-D-1PT IST jack. 1. Be sure the wiring between the ATI-D-1PT and the common equipment station ports is properly installed. 2. Measure for DC voltage on the IST jack: Measure between TIP leads and common equipment grounding stud. Measure between RING leads and common equipment grounding stud. Measure between TIP leads and RING leads. The measured voltage must be within following limits (with the IST device on-hook): Measurement Voltage Tip to Ground Ring to Ground Tip to Ring -1 to +1 VDC -27 to -38 VDC +28 to +37 VDC (The TIP lead is positive with respect to the RING lead.) 6 Installing The ATI-D-1PT
7 Installing And Programming The ATI-D-1PT IMI ATI2 Typical Station Connector Block CLIP TERMINALS Ferrite Collar Connect to a digital station board installed in the digital communications system. Common Equipment Jack Common Equipment Jack PIN 1 No Connection PIN 2 No Connection PIN 3 Digital Station (Tip) PIN 4 Digital Station (Ring) PIN 5 No Connection PIN 6 No Connection Earth Ground (Optional) ATI-D-1PT Line Jack Line Jack PIN 1 No Connection PIN 2 No Connection PIN 3 Tip PIN 4 Ring PIN 5 No Connection PIN 6 No Connection PIN Locations On Jacks - Front View OPX Long Loop Adapter On-Premise IST Jack Off-Premise IST Jack Connecting The ATI-D-1PT Installing The ATI-D-1PT 7
8 IMI Installing And Programming The ATI-D-1PT Installing An OPX Long Loop Adapter For Off-Premise Service The ATI-D-1PT is an on-premise device you must use an OPX long loop adapter if you wish to adapt the ATI-D-1PT to support an off-premise application. An OPX long loop adapter connects to a single telephone line and can greatly extend the line s loop length (the Proctor Model adapter*, for example, can extend line length to 30,000 feet). You can also use OPX long loop adapters to connect key systems (to share central office lines and system features). *Proctor & Associates Company, Redmond, WA. CAUTION When you connect an adapter to an off-premise extension (OPX), you must ensure that the telephone line routed to the OPX has primary protectors installed in series with the tip/ring pair to protect the user and the equipment from transient voltage spikes that can travel through the cable. The telephone company offers basic protection against this condition, but it is usually designed to protect only the central office circuits. To help ensure that voltage surges do not damage the system, you should install and properly ground gas discharge tubes or similar primary protection devices on the telephone line routed from the adapter to the off-premise extension. To install the OPX long loop adapter, 1. Follow manufacturer s instructions for unpacking, inspecting, mounting, and wiring the adapter unit. 2. Plug a modular cable into the system jack on the adapter and connect the opposite end of the cable to the IST jack on the ATI-D-1PT. 3. Plug a modular cord into the telephone jack on the adapter and connect the opposite end of the cord to the OPX line. 4. Plug the adapter power cord into a standard 117 VAC, 3-wire electrical outlet. 8 Installing The ATI-D-1PT
9 Installing And Programming The ATI-D-1PT IMI Programming For Analog Terminal Interface Operation The ATI-D-1PT allows you to connect IST equipment to a digital station port. The IST provides basic intercom service and the ability to access outside lines. You can program the IST station port for Prime Intercom, Prime Line, Prime Line Group, or Idle Line Preference. Default is for No Prime. You can set the station port to receive outside line ringing and to match either the pulse or tone dialing used by the IST. Detailing The Prime Intercom Operating Condition With key-system configured digital communications systems, a multiline telephone user can extend line access for call origination to an IST station by employing the call transfer feature. To provide outside line ringing to a prime intercom IST, program the ATI-D-1PT station port to have the ringing line preference feature and then enable ringing for all lines that you want to ring at the IST. With hybrid configured digital communications systems, you can make outside lines available to the IST for call origination by programming the IST for line group access. With line group access, the IST user can access an outside line by dialing the group access code over the intercom line. The digital communications system then selects one of the grouped lines for IST use. Prime Line Automatic Or Idle Line Preference You can program an outside line as a prime line at the station port through which the IST is being interfaced, or you can program that station port for idle line preference and then assign several lines to the station port. With either prime line automatic or idle line preference, the IST has outside line dial tone for call origination when its user lifts its handset. You can enable outside line ringing at the IST station port that you have the idle line preference programmed for either prime line automatic or idle line preference. Alternately, you can enable the ringing line preference feature for the IST station port. The intercom line is still available to an IST even though you have provided outside line access. After going off-hook, the IST user obtains intercom dial tone by performing a hookflash (press and release the hookswitch) or by pressing the TAP button if one is available. Hookflash either drops the outside line (if the user dialed no digits after lifting the handset) or (if the user dialed some digits) places the line on hold and provides intercom dial tone. Distinctive Ringing Intercom calls that ring at equipment connected through an ATI-D-1PT have a different cadence than outside calls. You can disable this distinctive ringing feature to make the intercom ring cadence identical to outside calls. Through Dialing You can program the station port through which the IST is being interfaced for through-dialing or you can disable the feature. The system automatically enables the feature when you connect an ATI-D-1PT to the station port. Through dialing enabled is necessary if the connected IST is a dual-tone multifrequency (DTMF) tone dial device that requires that its generated dialing tones pass through the ATI-D-1PT, the common equipment, and onto a tone dial compatible telephone line. If the IST is a rotary telephone, you must disable the through dialing feature. Installing The ATI-D-1PT 9
10 IMI Installing And Programming The ATI-D-1PT Programming Procedures The ATI-D-1PT automatically identifies itself as an analog terminal interface for the digital station board as soon as you connect it to the digital communications system. Prime Line Programming To set prime line type, When you enable this feature, the system automatically selects a line, line group, or intercom number for use when a station goes off-hook. 1. Go to STATIONS, then select STATION PROGRAMMING, then GENERAL. 2. From the Prime Type drop-down menu, select the type of Prime Type (no prime, line, line group, or intercom). 3. Click on the button beside the Prime Type drop-down menu and select the line, line group, or intercom number to serve as your Prime Type. 4. Click APPLY to add the changes to the database. NOTE: When making changes to the VMMI database off-line you must save the database if you wish to have a back-up copy. If you are programming on-line, changes to the VMMI database take effect as soon as you click APPLY. If you wish to create a back-up copy of the database after programming on-line, you must archive the database on your PC. 10 Installing The ATI-D-1PT
11 Installing And Programming The ATI-D-1PT IMI Idle Line Preference and Idle Line Priority The Idle Line Preference and Idle Line Priority features work in conjunction with each other. Idle Line Priority cannot be set unless Idle Line Preference is enabled. Idle Line Preference When you enable this feature, a station automatically connects to an idle line when the user lifts the telephone s handset. To set Idle Line Preference, 1. Go to STATIONS, then CLASS OF SERVICE. 2. Go to PAGE Make sure you are in the correct Class Of Service. 4. Click on IDLE LINE PREFERENCE. 5. Click APPLY. Idle Line Priority If you assign Idle Line Preference to a Class Of Service, use the Idle Line Priority feature to chose the order in which the system searches for an idle line. You can place up to eight lines in this priority list. To set Idle Line Priority, 1. Go to STATIONS, then STATION PROGRAMMING, then GENERAL. 2. Click on the IDLE LINE PRIORITY box. The Idle Line Priority On... dialog appears. 3. Select the lines you wish to put in the Idle Line Priority box by highlighting them and clicking ADD. Make sure you select the lines in the order you wish the system to search through them. 4. Click OK. 5. Click APPLY. Installing The ATI-D-1PT 11
12 IMI Installing And Programming The ATI-D-1PT Ringing Line Preference When you enable this feature, a station automatically connects to a ringing line when taken off-hook. 1. Go to STATIONS, then CLASS OF SERVICE. 2. Go to PAGE Make sure you are in the correct Class of Service. 4. Click on RINGING PREFERENCE. 5. Click APPLY. Dialing Mode Program the line port to provide either DTMF dialing or rotary (pulse) dialing line as required by the central office (CO). 1. Go to LINES, then LINE PROGRAMMING. 2. Go to LINE ATTRIBUTES. 3. Select the line for which you wish to set Dialing Mode. 4. Go to LINE TYPE SPECIFIC. 5. Make sure the Line Attributes for Line heading states the correct line. 6. From the Dialing Mode drop down list, select TONE or PULSE. 7. Click APPLY. Pulse Interdigit Time and Pulse Dial Make/Pulse Dial Break (Pulse Dial Ratio) The system defaults the Pulse Interdigit Time to 150 msec., but you can change this to any value between 100 msec. and 1 second. Set the make/break ratio for rotary dialing to match line requirements. You can set the make and break times in 1 msec. increments from 1 msec. to 99 msec. 1. Go to SYSTEM, then TIMING. 2. Go to DIAL TIMING. 3. In the Pulse Dialing box, use the drop-down menu to select the Pulse Interdigit Time. 4. Type the Pulse Break Time and Pulse Make Time in the corresponding boxes. 5. Click APPLY. 12 Installing The ATI-D-1PT
13 Installing And Programming The ATI-D-1PT IMI Flexible Ringing Assignments Program ringing assignments on a per station/per line/per intercom number basis. Ringing can be immediate, delayed, or special purpose. Direct Ringing Use this procedure to choose the line ports that you want to ring at a station as soon as a call appears. Direct ringing sounds during the Day 1 and Day 2 time periods but does not ring during the night ringing mode or during the manual night transfer (of ringing) operation. 1. Go to STATIONS, then STATION PROGRAMMING. 2. Go to RINGING ASSIGNMENTS. 3. Click on DIRECT RING Highlight the lines for which you wish to set Direct Ringing, and click ADD. 5. Click OK, then click APPLY. Delayed Ringing Line ports you assign to Delayed Ringing will prevent a call from ringing for a short time after the call arrives. Delayed Ringing sounds during day 1 and day 2 time periods, night ringing mode, and manual night transfer (of ringing) operation. 1. Go to STATIONS, then STATION PROGRAMMING. 2. Go to RINGING ASSIGNMENTS. 3. Click on DELAYED RING Highlight the lines for which you wish to set Delayed Ringing, and click ADD. 5. Click OK, then click APPLY Installing The ATI-D-1PT 13
14 IMI Installing And Programming The ATI-D-1PT Day 1 Ring Use this procedure to choose the line ports you want to ring at stations during the Day 1 ringing mode. Refer to the paragraph below titled, Day 1, Day 2, and Night Ringing Begin and End Times, to set the beginning and ending times for this ringing. 1. Go to STATIONS, then STATION PROGRAMMING. 2. Go to RINGING ASSIGNMENTS. 3. Click on DAY 1 RING Highlight the lines for which you wish to turn on Day 1 Ring, and click ADD. 5. Click OK, then click APPLY. Day 2 Ring Use this procedure to choose the line ports you want to ring at stations during the Day 2 ringing mode. Refer to the paragraph below titled, Day 1, Day 2, and Night Ringing Begin and End Times, to set the beginning and ending times for this ringing. 1. Go to STATIONS, then STATION PROGRAMMING. 2. Go to RINGING ASSIGNMENTS 3. Click on DAY 2 RING Highlight the lines for which you wish to turn on Day 2 Ring, and click ADD. 5. Click OK, then click APPLY. Day 1, Day 2, And Night Ringing Begin And End Times With this programming procedure, set the begin and end times of the Day 1, Day 2, and Night ringing time periods. 1. Go to SYSTEM, then PARAMETERS, then OPTIONS In the Ringing Times box, enter the begin and end times (in hh:mm format) for Day 1, Day 2, and Night ringing. 3. Click APPLY. 14 Installing The ATI-D-1PT
15 Installing And Programming The ATI-D-1PT IMI Night Ring (Night Transfer Of Ringing) Choose the line ports that you want to ring, along with the delayed ringing line ports, at stations during the night ringing mode of operation. The ringing arrangement that you configure here is the arrangement that is active both during the automatic night ringing time period and whenever the attendant manually activates the night transfer (of ringing) operation. Note that the attendant-commanded night ringing period supersedes the automatic night ringing period. Refer to the paragraph titled, Day 1, Day 2, and Night Ringing Begin and End Times, to set the time for the automatic night ringing period. 1. Go to STATIONS, then STATION PROGRAMMING. 2. Go to RINGING ASSIGNMENTS. 3. Click on NIGHT RING Highlight the lines for which you wish to turn on Night Ring, and click ADD. 5. Click OK, then click APPLY. Ring No-Answer Rings This procedure sets the number of rings that sound at a station port before the call rolls over to ring at another station. Any system feature that requires a ring no-answer value (for example, Call Forwarding) uses the setting that you program here. The system defaults the ring no-answer value at station ports to four rings, and at voice mail ports to three rings. 1. Go to STATIONS, then STATION PROGRAMMING. 2. Go to OPTIONS Highlight the station for which you wish to set the number of RNA rings. 4. From the RNA RINGS drop-down dialog, choose the number of RNA rings you wish to assign. 5. Click APPLY. 6. Repeat steps 3 5 for each station on which you wish to change the number of RNA rings. Installing The ATI-D-1PT 15
16 IMI Installing And Programming The ATI-D-1PT Personalized Ringing Tone Program a station to ring in one of several distinctive tones for proprietary digital telephones and in one of four distinctive tones for analog telephones. 1. Go to STATIONS, then STATION PROGRAMMING. 2. Go to RINGING ASSIGNMENTS. 3. Highlight the station for which you wish to set the ringing tone. 4. From the Personalized Ring Tone drop-down menu, select the number of the ring tone you wish to assign. 5. Click APPLY. 6. Repeat steps 3 5 for each station on which you wish to set a personalized ringing tone. IST Distinctive Ringing Industry-standard telephones do not provide personalized ringing, but you can program them to ring differently for intercom calls and outside calls, or to ring the same way for both types of calls. NOTE: Do not enable distinctive ringing for voice mail ports. 1. Go to STATIONS, then CLASS OF SERVICE. 2. Go to PAGE Select the COS (Class of Service) group for which you wish to set IST Distinctive Ringing. 4. If you want outside calls and intercom calls to ring differently, make sure the IST Distinctive Ringing box is checked. If you do not want different ringing patterns, leave the box unchecked. 5. Click APPLY. Through Dialing (Thru-Dialing) Thru-Dialing allows DTMF tones generated by an external IST device to pass through the system and out to any line connection. 1. Go to STATIONS, then STATION PROGRAMMING. 2. Go to OPTIONS Click the Thru-Dialing box. 4. Click APPLY. 16 Installing The ATI-D-1PT
17 This page remains blank intentionally.
18 R Charlottesville, Virginia World Wide Web:
Installing And Programming The Off-Premise Extension Interface On The Digital Communications System
R Installing And Programming The Off-Premise Extension Interface On The Digital Communications System 1.0 Introducing The Off-Premise Extension Interface This publication describes the features, applications,
More informationInstalling The Loop Start Line Board In The FX Series Digital Communications System
R In The FX Series Digital Communications System Introducing The Loop Start Line Board Defining Loop Start The line board signals for the host system to complete a line connection by sending a supervisory
More informationInstalling And Programming The Digital Voice Announce Equipment On The DXP, DXP Plus, And FX Series Systems
R Installing And Programming The Digital Voice Announce Equipment On The DXP, DXP Plus, And FX Series Systems Digital Voice Announce Equipment The digital voice announce device (DVA) is an optional line-powered
More informationInstalling The Personal Computer Interface Unit
R Introducing The Personal Computer Interface Unit The Personal Computer Interface Unit (PCIU) is a device that you can connect between a digital station port and its proprietary telephone. The PCIU allows
More informationSERVICE MANUAL MODEL SSW-321-X
SSW-321-X-ISSUE 4.0 SERVICE MANUAL FOR MODEL SSW-321-X STAINLESS STEEL WALL TELEPHONE Serving the Telephone Industry Since 1930 Communication Equipment 519 W South Park Street & Engineering Company Okeechobee,
More informationInstalling and Programming the Caller ID Feature
R Installing and Programming the Caller ID Feature 1.0 Introducing the Caller ID Feature The caller ID feature supports an externally connected, customer-supplied caller ID device. Depending on the model
More informationInstalling The DSU II Digital Telephone System
IMI66 32 2 Installing The DSU II Digital Telephone System Section Title... Page 2. Considering the Mounting Requirements...2 4 2.. Tools And Hardware...2 5 2..2 Underwriters Laboratories Installation Notice...2
More informationSERVICE MANUAL MODEL SSP-363-E (FORMERLY SSP-365-E)
SSP-363-E-(SSP-365-E)-ADT1.03-ISSUE4.0 SERVICE MANUAL FOR MODEL SSP-363-E (FORMERLY SSP-365-E) STAINLESS STEEL PANEL TELEPHONE WITH 12 BUTTON AUTOMATIC DIALER EQUIPPED WITH ADT1.03 FIRMWARE Serving the
More informationSERVICE MANUAL MODEL SSW-520-F
SSW-520-F-ISSUE4.0 SERVICE MANUAL FOR MODEL SSW-520-F HANDS FREE STAINLESS STEEL TELEPHONE EQUIPPED WITH LOW POWER SPEAKER BOARD Serving the Telephone Industry Since 1930 Communication Equipment 519 West
More informationSERVICE MANUAL. MODEL SSW-321-Fr1
SSW-321-Fr1-XFD-ISSUE5.0 SERVICE MANUAL FOR MODEL SSW-321-Fr1 MINI WALL TELEPHONE EQUIPPED WITH RECEIVER-OPERATED MAGNETIC HOOKSWITCH; INTERNAL VOLUME CONTROL AND NOISE REDUCTION CIRCUIT; XFD PCB. Serving
More informationJunos WebApp Secure 5.0 Hardware Guide
Junos WebApp Secure 5.0 Hardware Guide Junos WebApp Secure 5.0 Hardware Guide This document contains a specification for the MWS1000 hardware appliance, as well as instructions for installation into a
More informationSERVICE MANUAL MODEL SSW-321-F MODEL BLW-321-F
SSW-321-F OR BLW-321-F-ISSUE4.0 SERVICE MANUAL FOR MODEL SSW-321-F OR MODEL BLW-321-F MINI WALL TELEPHONE Serving the Telephone Industry Since 1930 Communication Equipment 519 W South Park Street & Engineering
More informationSERVICE MANUAL FOR. MODEL MHW-341-Fr1 MAGNETIC HOOKSWITCH WALL TELEPHONE
MHW-341-Fr1-XFD-ISSUE5.0 SERVICE MANUAL FOR MODEL MHW-341-Fr1 MAGNETIC HOOKSWITCH WALL TELEPHONE EQUIPPED WITH VOLUME CONTROL, BACKGROUND NOISE ELIMINATION, XFD PRINTED CIRCUIT, AND RECEIVER- OPERATED
More informationInstallation of the POTS splitter card requires the following steps: Determining the cables you need. Installing the POTS splitter chassis
5910 High Density Lifeline POTS Splitter Installation Instructions Document Number 5910-A2-GZ40-00 May 2005 About the 5910 POTS Splitter The 5910 is a double-density POTS splitter that separates the (Digital
More informationSERVICE MANUAL MODEL SSW-321-D
SSW-321-D-XFD-ISSUE4.0 SERVICE MANUAL FOR MODEL SSW-321-D MINI WALL TELEPHONE EQUIPPED WITH XFD PRINTED CIRCUIT BOARD Communication Equipment & Engineering Company Serving the Telephone Industry Since
More informationSERVICE MANUAL MODEL SSW-521-F (FORMERLY SSW-521-FS)
SSW-521-F-SPK1.07UNVL-ADA-ISSUE4.0 SERVICE MANUAL FOR MODEL SSW-521-F (FORMERLY SSW-521-FS) STAINLESS STEEL HANDS FREE WALL TELEPHONE OPTIONAL ADA FEATURE AVAILABLE EQUIPPED WITH SPK1.07UNVL FIRMWARE Serving
More informationSERVICE MANUAL MODEL SSP-550-X (FORMERLY SSP-510-X)
SSP-550-X-(SSP-510-X)-LPSPKRPCB-ADA-ISSUE4.0 SERVICE MANUAL FOR MODEL SSP-550-X (FORMERLY SSP-510-X) HANDS FREE ELEVATOR PHONE EQUIPPED WITH LOW-POWER SPEAKER BOARD Serving the Telephone Industry Since
More informationImpact Attendant for Windows PC Attendant Console User s Guide For The DXP, DXP Plus and FX Series Digital Communications Systems
Impact Attendant for Windows Impact Attendant for Windows PC Attendant Console User s Guide For The DXP, DXP Plus and FX Series Digital Communications Systems Comdial strives to design the features in
More informationSERVICE MANUAL MODEL SSC-303-F (FORMERLY 303-FS)
SSC-303-F-650-521-CAC6.00-ISSUE4.1 SERVICE MANUAL FOR MODEL SSC-303-F (FORMERLY 303-FS) CHARGE-A-CALL TELEPHONE EQUIPPED WITH CAC6.00 FIRMWARE Serving the Telephone Industry Since 1930 Communication Equipment
More informationInstalling the Cisco VG224 Voice Gateway
CHAPTER 3 This chapter contains the procedures for installing your Cisco VG224 voice gateway and consists of the following sections: Safety Recommendations, page 3-2 Site Log, page 3-3 Keeping Track Checklist,
More informationSERVICE MANUAL MODEL WPP-531-X-ADA MODEL SSP-511- X-ADA
WPP-531-X-ADA OR SSP-511-X-ADA-SPK1.07-ISSUE4.0 SERVICE MANUAL FOR MODEL WPP-531-X-ADA HANDS FREE EMERGENCY WEATHERPROOF TELEPHONE OR MODEL SSP-511- X-ADA HANDS FREE STAINLESS STEEL PANEL TELEPHONE EQUIPPED
More informationSERVICE MANUAL FOR MODEL WPP-531-D WEATHERPROOF TELEPHONE WITH OPTIONAL ADA FEATURE
WPP-531-D OR SSP-511-D-SPK1.07UNVLr1-ADA-ISSUE4.0 SERVICE MANUAL FOR MODEL WPP-531-D WEATHERPROOF TELEPHONE WITH OPTIONAL ADA FEATURE OR MODEL SSP-511-D STAINLESS STEEL PANEL TELEPHONE WITH OPTIONAL ADA
More informationEP/2 Installation Instructions
1 2 3 4 7 ENTER 0 5 6 8 9 CLEAR + - LOGIC ONE EP/2 EP/2 Installation Instructions DOC. #569011000 A 7/30/04 PRINTED IN U.S.A. Regulatory Compliance Safety This device has been tested and found to be in
More informationSERVICE MANUAL MODEL SSW-521-D2-ADA
SSW-521-D2-ADA-SPK1.07UNVLr3-ADA-ISSUE4.0 SERVICE MANUAL FOR MODEL SSW-521-D2-ADA STAINLESS STEEL HANDS FREE WALL TELEPHONE WITH OPTIONAL ADA FEATURE AND OPTIONAL SECOND-NUMBER AUTO-DIAL FEATURE EQUIPPED
More informationDXP, DXP Plus, Impact FX Digital Communication System
DXP, DXP Plus, Impact FX Digital Communication System General Description For The Common Code Base Software Feature Set 13B The information in this publication is applicable for software Feature Set 13B.
More informationSERVICE MANUAL FOR MODEL WPP-531-X-ADA-STROBE WEATHERPROOF TELEPHONE WITH OPTIONAL STROBE FEATURE. EQUIPPED WITH SPK1.
WPP-531-X-ADA-STROBE(LP3P)-SPK1.07UNVLr3-ISSUE4.0 SERVICE MANUAL FOR MODEL WPP-531-X-ADA-STROBE WEATHERPROOF TELEPHONE WITH OPTIONAL STROBE FEATURE EQUIPPED WITH SPK1.07UNVLr3 FIRMWARE Serving the Telephone
More informationOPERATOR S MANUAL MODEL LS110 MINI-PBX SIMULATOR
1 OPERATOR S MANUAL MODEL LS110 MINI-PBX SIMULATOR Micro Seven, Inc. 1095-K N.E. 25 th Hillsboro, OR 97124 U.S.A. phone: 503-693-6982 fax: 503-693-9742, email to: sales@microseveninc.com www.microseveninc.com
More informationInstalling the Fiber Optics Card
R Installing the Fiber Optics Card The Rising Star TM Understanding the Fiber Optics Card The Fiber Optics card provides an optical interconnection between the main and expansion cabinets in an expanded
More informationSERVICE MANUAL MODEL SSC-301-F (FORMERLY 301-FS) MODEL BLC-301-F (FORMERLY 301-F)
SSC-301-F OR BLC-301-F-ISSUE4.0 SERVICE MANUAL FOR MODEL SSC-301-F (FORMERLY 301-FS) OR MODEL BLC-301-F (FORMERLY 301-F) CHARGE-A-CALL TELEPHONE Serving the Telephone Industry Since 1930 Communication
More informationNT1B-300 Rack Installation Instructions
The NT1B-300 Rack houses 24 Tone Commander NT1B-300TC ISDN Network Terminations in a 19 rack, 23 rack, or wall mount configuration. The rack is also compatible with Lucent NT1B-300 NT1s. The rack supplies
More informationSERVICE MANUAL MODEL SSC-303-D (FORMERLY 303-DS)
SSC-303-D(303DS)-ADI2.01-650-541-ISSUE4.0 SERVICE MANUAL FOR MODEL SSC-303-D (FORMERLY 303-DS) STAINLESS STEEL AUTOMATIC DIALING TELEPHONE EQUIPPED WITH ADI2.01 FIMWARE Serving the Telephone Industry Since
More informationInstallation Notes TII Model 341 Protector
Installation Notes TII Model 341 Protector (ATT-IS PEC 32918) for MERLIN Communications System In Range Out of Building (IROB) Station Installation By Trained Technician Only WARNING: Failure to follow
More informationIndustry Standard Telephone (IST) Station User s Guide. DXP, DXP Plus, and FX Digital Telephone Systems
Industry Standard Telephone (IST) Station User s Guide DXP, DXP Plus, and FX Digital Telephone Systems This user s guide applies to industry standard single-line telephones such as the model 2500-** when
More informationInstallation Job Aid for Ethernet Routing Switch 3600 Series
Installation Job Aid for Ethernet Routing Switch 3600 Series Notices NN47213-303 Issue 03.01 November 2017 Notice paragraphs alert you about issues that require your attention. Following are descriptions
More informationEntraGuard Bronze. Quick Start Guide. Telephone Entry. 1.0 Specifications. 2.0 Unit Installation
The EntraGuard Bronze is a residential telephone keypad entry system which allows a homeowner to communicate directly with visitors and provide access by using any phone extension in the home. Because
More informationSERVICE MANUAL FOR MODEL WPP-531-D WEATHERPROOF TELPHONE OR MODEL HOB-531-D WEATHER RESISTANT TELPHONE
WPP(HOB)-531-D OR SSP-511-D-SPK1.07UNVLADA-ADA-ISSUE4.0 SERVICE MANUAL FOR MODEL WPP-531-D WEATHERPROOF TELPHONE OR MODEL HOB-531-D WEATHER RESISTANT TELPHONE OR MODEL SSP-511-D STAINLESS STEEL PANEL TELEPHONE
More informationSERVICE MANUAL FOR MODEL SSC-500-F (FORMERLY 501-FSZ) STAINLESS STEEL HANDS FREE CHARGE-A-CALL TELEPHONE EQUIPPED WITH LOW-POWER SPEAKER BOARD
SSC-500-F-(501-FSZ)-ISSUE4.0 SERVICE MANUAL FOR MODEL SSC-500-F (FORMERLY 501-FSZ) STAINLESS STEEL HANDS FREE CHARGE-A-CALL TELEPHONE EQUIPPED WITH LOW-POWER SPEAKER BOARD Serving the Telephone Industry
More informationPower Supply. Users Guide PRODUCT MANUAL. WESTELL.COM Westell Technologies MNL rd
PRODUCT MANUAL Power Supply Westell Technologies. 960-1152-MNL rd DISCLAIMER All information and statements contained herein are accurate to the best of Westell Technologies knowledge. Westell Technologies
More informationSuperBus 2000 Phone Interface/Voice Module Installation Instructions
SuperBus 2000 Module Installation Instructions Product summary The SuperBus 2000 (PIV) Module provides phone and voice functions for the Concord, Concord 4, and Concord Express (v4) panels. The PIV module
More informationData Isolation Cards. ADSL High Voltage Isolation Card. Single Line Voice Isolation Card With CID, CW & MWI. Floated 130VDC or 120VAC Input P30121
Data Isolation Cards ADSL High Voltage Isolation Card Single Line Voice Isolation Card With CID, CW & MWI Floated 48VDC Input P30120 Floated 130VDC or 120VAC Input P30121 Description & Installation Printed
More informationSERVICE MANUAL MODEL WPP-331-D WEATHERPROOF TELEPHONE MODEL HOB-331-D WEATHER RESISTANT TELEPHONE. and MODEL SSP-311-D STAINLESS STEEL PANEL TELEPHONE
WPP(HOB)-331-D or SSP-311-D ATD-11 Issue 5.00 SERVICE MANUAL FOR MODEL WPP-331-D WEATHERPROOF TELEPHONE MODEL HOB-331-D WEATHER RESISTANT TELEPHONE and MODEL SSP-311-D STAINLESS STEEL PANEL TELEPHONE EQUIPPED
More informationOmnitron Systems Technology, Inc. 1. iconverter. 19-Module Managed Power Chassis User s Manual
Omnitron Systems Technology, Inc. 1 iconverter 19-Module Managed Power Chassis User s Manual 27 Mauchly, #201, Irvine, CA 92618 Phone: (949) 250-6510; Fax: (949) 250-6514 2 Omnitron Systems Technology,
More informationSERVICE MANUAL FOR MODEL WPP-531-D2 WEATHERPROOF TELEPHONE OR MODEL HOB-531-D2 WEATHER RESISTANT TELEPHONE
WPP(HOB)-531-D2 OR SSP-511-D2-SPK1.07UNVL-ADA-ISSUE4.0 SERVICE MANUAL FOR MODEL WPP-531-D2 WEATHERPROOF TELEPHONE OR MODEL HOB-531-D2 WEATHER RESISTANT TELEPHONE OR MODEL SSP-511-D2 STAINLESS STEEL PANEL
More informationPower Supply (48Vdc, 2.5A)
Telecommunications Group Section 855-180-201 Equipment Issue 1 Fourth Printing, September 2006 8551-80 Power Supply (48Vdc, 2.5A) Compliant with UL Standard 60950, Second Edition* CONTENTS PAGE Part 1.
More informationCIB 3125 (122A) Off-Premises Range Extender. Installation Instructions. Installed By Qualified Technician Only CIB
CIB 3125 (122A) Off-Premises Range Extender Installation Instructions Installed By Qualified Technician Only CIB 3125 106793441 1992 AT&T All Rights Reserved Printed in USA Issue 3 August 1992 NOTICE Every
More informationChapter 2. Installing the Chapter 2. Contents
Contents Chapter 2 Installing the 3512 Overview... 2-2 Unpacking... 2-2 Telephone Equipment... 2-3 Customer-Provided Telephone Equipment... 2-3 Telephone Company Procedures and Regulatory Requirements...
More informationISO 9001 Certified. Call for Outlook User s Guide PRELIMINARY 7/99
R ISO 9001 Certified Call for Outlook User s Guide Printed in U.S.A. PRELIMINARY GCA70-363.01 7/99 Comdial strives to design the features in our communications systems to be fully interactive with one
More informationDSU II. System Manual. Digital Telephone System. Supports Impact, Impression, DigiTech, and Scout Telephones
DSU II Digital Telephone System System Manual This publication is applicable to the following common equipment: J0408, J0816, and J1632 with software revision 2A and later Supports Impact, Impression,
More informationIntelligent Channel Bank Shelf
Telecommunications Group Section 360-080-204 Equipment Issue 4 Third Printing, August 2006 360-80 Intelligent Channel Bank Shelf CONTENTS PAGE Part 1. GENERAL.............................................................................
More informationPRODUCT DESCRIPTION SPECIFICATIONS INSTALLATION. Dialer codes PRODUCT DIAGRAM. DL2 Dialer Module Digital Alarm Communicator Transmitter. Warning!
PRODUCT DESCRIPTI The DL is a dialer module, which contains a Digital Alarm Communicator Transmitter (DACT). The dialer sends alarm, supervisory, and trouble information to a compatible Digital Alarm Communicator
More informationSite Preparation CHAPTER
CHAPTER 3 Site Preparation This chapter describes the steps to take and the considerations you should keep in mind prior to installing the modules in an open rack. It also contains information that applies
More informationC5C Cross-Connect System
C5C Cross-Connect System I N S T A L L A T I O N I N S T R U C T I O N High-Density Connection Blocks 1.0 General Product Information The C5C cross-connect system is comprised of a high-density connection
More informationService Manual For. -IP Voice over Internet Protocol -ACH** Handset cord length Inches
SSP-3-F -ISSUE 4.0 Service Manual For -IP Voice over Internet Protocol -ACH** Handset cord length Inches -M Magnetic Hookswitch -CCH Coiled cord length Feet 5, 0, or 5 -BK Braille Keypad -PBVC Pushbutton
More informationRMB-3 Peripheral Unit. Installation Guide INSTALLATION GUIDE WESTELL.COM. Westell Technologies Part # Rev. A
RMB-3 Peripheral Unit Installation Guide INSTALLATION GUIDE Westell Technologies Part # 030-300812 Rev. A Copyright 2017 by Westell Technologies. All Rights Reserved. The material discussed in this publication
More informationDigital Telephone System System Manual
Digital Telephone System System Manual For The Impact DSU This publication is applicable to the following equipment: G0408, with software I0408, revision 18A and later G0816, with software I0816, revision
More informationDXP, DXP Plus, Impact FX Digital Communication System. General Description For The Common Code Base Software Release 173, Feature Set 15B
DXP, DXP Plus, Impact FX Digital Communication System General Description For The Common Code Base Software Release 173, Feature Set 15B The information in this publication is applicable for software Feature
More informationTechnical Practice GS-1 LOOP START TO GROUND START CONVERTER. Issue 7, December, Contents. Testing and Operation. Repair and Replacement
www.gkinc.com support@gkinc.com Technical Practice Issue 7, December, 1993 Contents Section 1 Section 2 Section 3 Section 4 Section 5 Section 6 Section 7 Section 8 Section 9 General Description Applications
More informationPerle MCR200 Installation Guide
Perle MCR200 Installation Guide P/N 5500322-10 Introduction The Perle MCR200 Chassis is a 2 slot chassis able to accommodate up to 2 Perle Media Converter modules or 1 Media Converter Module and an MCR-MGT
More information1. Carefully unpack the um260 s shipping carton and check the contents for damage.
um260 Installation Manual um260 Installation Chapter 4 um260 MICRO MONITOR INSTALLATION This section of the um260 Micro Monitor Installation Manual describes the requirements and procedures for installing
More informationRMB Peripheral Units Installation Guide
RMB Peripheral Units Installation Guide Part Number 65-000101 2011 by Kentrox, Inc. All rights reserved. Copyright 2011 by Kentrox, Inc. All Rights Reserved. The material discussed in this publication
More informationTRC-190 User s Manual
User s Manual Edition 3.2, May 2017 www.moxa.com/product 2017 Moxa Inc. All rights reserved. User s Manual The software described in this manual is furnished under a license agreement and may be used only
More informationSERVICE MANUAL MODEL SSP-350-X
SSP-350-X-ISSUE4.0 SERVICE MANUAL FOR MODEL SSP-350-X PRISON VISITATION TELEPHONE Serving the Telephone Industry Since 1930 Communication Equipment 519 W South Park Street & Engineering Company Okeechobee,
More informationRadio Shack Telephone Tester ( )
Radio Shack Telephone Tester (430-0114) Telephone Tester (430-0114) Features Faxback Doc. # 15708 The Radio Shack Telephone Tester represents a multi-function, value featured advance in telephone service
More informationTotal Reach ISDN/DDS Isolation Card P P30059 Isolation Card
Total Reach ISDN/DDS Isolation Card P30101 120VAC/130VDC to 24VDC External Power Supply Without Backup Battery P30059 Isolation Card Description & Installation Printed in USA 09/11 T0346 Rev. C Table of
More informationHOUSING DEVICES, INC. HDI ADA - ARCU. Installation & Operations Manual. Made in the USA
HOUSING DEVICES, INC. ADA - ARCU Installation & Operations Manual Made in the USA ADA - ARCU 5 & 10 Pre-Installation Requirements: For each ADA-1000 in the elevator you must run a twisted, shielded, 22
More informationNT1-220 Rack. Installation Instructions. Specifications. Contents of Shipping Box. Important Safety Instructions. NT1-220 Rack
The NT1-220 Rack is designed to be used in conjunction with Tone Commander NT1U-220TC ISDN Network Terminations. A maximum of twelve NT1 units can be used in each rack. NT1-220 Rack Installation Instructions
More informationSERVICE MANUAL MODEL SSP-561-X-ADA
SSP-561-X-ADA- SPK1.07r2-ISSUE4.0 SERVICE MANUAL FOR MODEL SSP-561-X-ADA HANDS FREE STAINLESS STEEL PANEL TELEPHONE EQUIPPED WITH BRAILLE EMERGENCY PLATE AND SPK1.07r2 FIRMWARE Serving the Telephone Industry
More informationIMI /02 printed in U.S.A. FX II Digital Communications System Cabinet Installation Instructions
IMI66 143.03 02/02 printed in U.S.A. FX II Digital Communications System Cabinet Installation Instructions Comdial strives to design the features in our communications systems to be fully interactive with
More informationHardware Manual INS05 June Installing the Cabinet. 2. PCB Installation 3. Installing Extensions and Trunks. 4. Optional Equipment
Hardware Manual 80000INS05 June 2000 6/16/00 1. Installing the Cabinet 2. PCB Installation 3. Installing Extensions and Trunks 4. Optional Equipment 5. Maintenance Options and SMDR 6. Specifications and
More informationNI PXIe-1062Q Power Supply Shuttle
USER GUIDE NI PXIe-1062Q Power Supply Shuttle The NI PXIe-1062Q power supply shuttle is a replacement part for the NI PXIe-1062Q chassis. Caution This power supply is not compatible with any other National
More informationMulti Cell Wireless Telephone User s Guide. For Comdial Systems
R Multi Cell Wireless Telephone User s Guide For Comdial Systems This user s guide applies to the following system and telephone models: System Models: DXP systems with software 12A and later. DXP Plus
More informationService Manual For. -IP Voice over Internet Protocol -ACH** Handset cord length Inches
Service Manual For -IP Voice over Internet Protocol -ACH** Handset cord length Inches -M Magnetic Hookswitch -CCH Coiled cord length Feet 5, 10, or 15 -BK Braille Keypad -PBVC Pushbutton volume control
More informationDigital Telephone System. Speakerphone and Monitor Telephone Station User s Guide
R Digital Telephone System Speakerphone and Monitor Telephone Station User s Guide GHI PRS 1 ABC2 4 7 JKL TUV OPER 5 MNO6 8 WXY9 0 DEF 3 # SPKR T/C MUTE HOLD TAP ITCM unisyn01.cdr This user s guide applies
More informationInstalling the Cisco AS5400XM Universal Gateway
CHAPTER 3 Installing the Cisco AS5400XM Universal Gateway This chapter guides you through the installation of the Cisco AS5400XM universal gateway and includes the following sections: Setting Up the Chassis,
More informationCOM32. Installation & Operation Manual
COM32 Installation & Operation Manual DANGER ElectricaI equipment contains hazardous voltages and high speed moving parts. Can cause death, serious injury or property damage. See safety instruction contained
More informationHardware Manual 80000INS07 April 2001 (2106)
Hardware Manual 80000INS07 April 2001 (2106) Printed in U.S.A. 1. Installing the Cabinet 2. PCB Installation 3. Installing Extensions and Trunks 4. Optional Equipment 5. Maintenance Options and SMDR 6.
More informationFour IFB. Multi Line Phone Bridge. User Guide. JK Audio. Warranty
Warranty Four IFB is covered by a 2-year warranty to be free from defective workmanship and materials. In the event that the Four IFB needs repair, you must call us to get an authorization, and then carefully
More informationReplacing the Power Supply
APPENDIX B This appendix includes information on how to replace the power supply for the Cisco AS550XM universal gateway and contains the following sections: Safety Recommendations, page B-1 Required Tools
More informationRhino Buffer Module PSM24-BFM600S. Operating Instructions
Rhino Buffer Module PSM24-BFM600S Operating Instructions RHINO BUFFER MODULE PSM24-BFM600S Description The PSM24-BFM600S Buffer Module will hold the output voltage of a 24 VDC power supply after brownouts
More informationAT&T. PARTNER Communications System Remote Administration Unit. Installation and Use
AT&T PARTNER Communications System Remote Administration Unit Installation and Use Copyright 1994 AT&T All Rights Reserved Printed U.S.A. AT&T 518-455-050 Issue 1 April 1994 Notice Every effort was made
More informationInnoMedia ipbx-400. Quick Install Guide.
InnoMedia ipbx-400 Quick Install Guide www.innomedia.com Table of Contents Introduction 2 Package Contents 2 Installation 3 Wall-Mounting Instructions 5 Troubleshooting 6 Appendix A. LED Status Summary
More informationHardened 10/100Base-TX IEEE802.3at PoE PSE Ethernet Extender
Quick Start Guide This quick start guide describes how to install and use the Hardened Ethernet Extender. This is the Hardened Ethernet Extender of choice for harsh environments constrained by space. Physical
More informationTRC-190 User s Manual
First Edition, November 2008 www.moxa.com/product 2008 Moxa Inc. All rights reserved. Reproduction without permission is prohibited. The software described in this manual is furnished under a license agreement
More informationInstalling the Cisco 2524 and Cisco 2525 Routers
CHAPTER 3 Installing the Cisco 2524 and Cisco 2525 Routers This chapter guides you through the installation of the Cisco 2524 and Cisco 2525 routers and includes the following sections: Required Tools
More informationLine Impedance Stabilization Network (LISN)
Model 3816/2 Line Impedance Stabilization Network (LISN) User Manual ETS-Lindgren Inc. reserves the right to make changes to any product described herein in order to improve function, design, or for any
More informationCiAC A239AXXX Sealed T1 Mini-Repeater
Telecommunications Group Section A23-9AX-300 Equipment Issue 1 Fourth Printing, December 2002 CiAC A239AXXX Sealed T1 Mini-Repeater CONTENTS PAGE Part 1. GENERAL.............................................................................
More informationACCURATE ELECTRONICS INC PO BOX SW HALL BLVD BEAVERTON OR USA FAX
Page 1 of 6 Model 104445A January 2014 ACCURATE ELECTRONICS INC PO BOX 1654 97075-1654 8687 SW HALL BLVD 97008 BEAVERTON OR USA 503.641.0118 FAX 503.646.3903 WWW.ACCURATE.ORG Practice Section 104445A Rev
More informationNI PXI-1042 POWER SUPPLY SHUTTLE USER GUIDE
NI PXI-1042 POWER SUPPLY SHUTTLE USER GUIDE Introduction Unpacking The NI PXI-1042 power supply shuttle is a replacement part for the PXI-1042 chassis. To minimize downtime caused by a power-supply failure,
More informationTECHNICAL. Extend Your Phone System s Features and Forward Calls to Telecommuters. RAD-AMP Amplified Remote Access Device
TECHNICAL Practice TELECOM SOLUTIONS FOR THE 21ST CENTURY RAD-AMP Amplified Remote Access Device June 24, 2002! Extend Your Phone System s Features and Forward Calls to Telecommuters The RAD-AMP extends
More informationWIRESPEED ADSL MODEM (MODEL 2000) User Guide
WIRESPEED ADSL MODEM (MODEL 2000) User Guide Copyright 2001 Westell, Inc. All rights reserved. 030-300187 Rev. A Printed in the United States of America December 2001 CONTENTS 1. PRODUCT DESCRIPTION...
More informationOperation Connection: See Figure 1 Keypad: Figure 2
PN: 84-902 1/13 Overview The Triplett TeleTalker 330 is a rugged and durable professional Telephone Test Set providing all of the basic features necessary to test and maintain analog telephone installations.
More informationCIB 3128 Basic Telephone and Modem Interface 2
CIB 8 Basic Telephone and Modem Interface CIB 8 Comcode 05-656-064 Issue CIB 8 Basic Telephone And Modem Interface The Basic Telephone and Modem Interface (BTMI-) allows you to connect most types of on-premises
More informationVIP-812A DUAL NETWORKED STATION PORT
ISSUE 1 VIP-812A DUAL NETWORKED STATION PORT INTRODUCTION The VIP-812A Dual Networked Station Port allows most loop start terminal devices to be connected to a managed IP-based LAN/WAN. SPECIFICATIONS
More informationService Manual For. -IP Voice over Internet Protocol -ACH** Handset cord length Inches
Service Manual For -IP Voice over Internet Protocol -ACH** Handset cord length Inches -M Magnetic Hookswitch -CCH Coiled cord length Feet 5, 10, or 15 -IVC Internal Volume Control & Background Noise Reduction
More informationAnalog Monitor Installation Manual
Analog Monitor Installation Manual Part Number: 144-23919 Copyright 2011 Magnetek 1. Preface and Safety Magnetek manufactures products used as components in a wide variety of industrial systems and equipment.
More informationHypercable injecteur HPOE - Industrial IEEE 802.3at Gigabit PoE Injector. User Manual. v.1.0 Jun Mail :
Industrial IEEE 802.3at Gigabit PoE Injector User Manual v.1.0 Jun-2011 FCC Warning This Equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15
More information9109 FXS Analog Voice Application Module (APM) Installation Instructions. Product Documentation on the World Wide Web
TM 9109 FXS Analog Voice Application Module (APM) Installation Instructions Document Number 9109-A2-GN12-40 May 1999 Product Documentation on the World Wide Web We provide complete product documentation
More informationInstallation Job Aid for Ethernet Routing Switch 5900 Series
Installation Job Aid for Ethernet Routing Switch 5900 Series Notices NN47211-301 Issue 05.01 November 2017 Notice paragraphs alert you about issues that require your attention. The following paragraphs
More informationQuick Start. This document describes how to install the Juniper Networks PTX5000 Packet Transport
PTX5000 Packet Transport Router Quick Start September 2017 Part Number: 530-066788 Revision 01 This document describes how to install the Juniper Networks PTX5000 Packet Transport Router. Contents Quick
More informationEAR K. Installation and Programming. Manual
EAR 2000 4K Installation and Programming Manual EAR 2000 4K Installation and Programming Manual Release 1 Version 3 June 2011 NOTICE This publication refers to the EAR 2000, Release 3. Additional copies
More information