Nimble Tech Preview Nimble tech preview released. VVol 2.0 GA with vsphere 6.5 3PAR & Nimble ready on Day 1

Size: px
Start display at page:

Download "Nimble Tech Preview Nimble tech preview released. VVol 2.0 GA with vsphere 6.5 3PAR & Nimble ready on Day 1"

Transcription

1

2 A Brief History of 3PAR, Nimble & VMware VVols Design partnership between HPE and VMware Virtual Volumes VMworld VVol introduced with HPE as 1 of 5 original design partners VVol Beta 3PAR 1 of 3 partners ready on Beta Day 1 Nimble Tech Preview Nimble tech preview released VVol 2.0 GA with vsphere 6.5 3PAR & Nimble ready on Day 1 Aug 2011 Jul 2014 Jun 2015 Nov 2016 May 2012 Mar 2015 Mar 2016 Today 3PAR Reference Platform 3PAR selected as the FC reference platform VVol GA with vsphere 6.0 3PAR 1 of 4 partners ready Nimble GA Nimble releases VVol support Continued development 3PAR, Nimble and VMware continue working to develop and refine VVols

3 Why did VMware create a new storage architecture? Todays exercise: Challenges in external storage architectures LUN Centric storage preallocated into silos No Visibility cannot see inside VMFS volume Poor Efficiency typically overprovisioning LUNs Increased Administration must always go to storage admin Difficult Reclamation space reclamation is a manual process Hardware Centric must use vendor tools & plug-ins Long Provisioning time consuming manual requests Data Services array data services not aligned with VMs Key take-away: There are many hidden challenges with traditional external storage architectures in vsphere which decrease efficiency and increase management

4 What are VMware VVols? New vsphere storage architecture to replace VMFS/NFS Standard (VASA) for all storage vendors to adhere to Enables vsphere to write VMs natively to storage arrays Common storage management tasks are automated Designed to be dynamic, eliminates LUN provisioning Storage array features can be applied to individual VMs Key take-away: VVols provides automated and dynamic management of storage resources and enables storage arrays to interact directly with VMs

5 How VVols transforms storage in vsphere VMFS LUN-Centric Siloed storage pools, array services aligned to LUNs Static Pre-allocated storage, over- provisioned resources Complex Complicated management using vendor specific tools Time-consuming Longer provisioning, manual space reclamation VVols VM-Centric No siloed storage pools, array services aligned to VMs Dynamic Dynamically allocated storage, using only what is needed Simple Simplified management using vsphere interfaces Effortless Instant provisioning, automatic space reclamation

6 What changes between file and block protocols with VVols Host adapter I/O transport Host present File system VM storage Storage visibility File Block iscsi initiator (sw/hw) or HBA NFS Client Network or fabric Storage LUNs container vsphere vsphere managed native (VMFS) VMDK VVols files Array Storage vsphere Network Mount point managed VMDK VVols files container native (NFS) Data store VM level Level VM level

7 Overview of VVols Storage Architecture Protocol Endpoint: Logical I/O proxy that serves as the data path between ESXi hosts to VMs and their respective VVols ESXi hosts VM VM VM VM VM vcenter Server SPBM VASA Provider: Software component that mediates out-ofband communication for VVols traffic between vcenter Server, ESXi hosts & storage array Data Path Control Path Storage Container: Pool of raw storage capacity that becomes a logical grouping of VVols, seen as a virtual datastore by ESXi hosts Virtual Volume (VVol): Container that encapsulates VM files, virtual disks and their derivatives Storage Profile: Set of rules that define storage requirements for VMs based on capabilities provided by storage array (same as VSAN) VVOLs Protocol Endpoint VASA Provider Storage Container Storage Array

8 Storage Policy-Based Management 1. Storage Array advertises capabilities via VASA Provider 2. Storage Policies created in vsphere and assigned array capabilities Policy 1 Policy 2 Policy 3 4. SPBM provisions VM on appropriate storage as defined by policy and maintains compliance 3. VMs assigned a Storage Policy based on requirements and SLAs

9 Top Reasons Customers will want to Start Using VVols Now 1. Don t have to go all in 2. Get early experience 3. Get your disk space back 4. Available in all vsphere editions 5. Let the array do the heavy lifting 6. Start using SPBM now 7. Snapshots don t suck anymore 8. Easier for IT Generalists 9. One architecture to rule them all Available You Easier Get One Start Let Snapshots The the your early VM don t architecture using for array is disk VVol to IT now don t SPBM all go a all unit Generalists in experience space vsphere the now suck to with rule of heavy anymore storage back them VVols editions lifting all Because You It s An No Don t and array more longer can wait get need architecture in it s use the over-provisioning left have until all a to darkness VVols purpose out, about be the to a get wait not last storage alongside the started built bind a hours VM, I/O or no manual of minute. feature, engine, using for admin, them more VMFS, I/O -the intensive NFS, LUNs fully How space array nothing same easy manage iscsi, long features reclamation, migration the SPBM to snapshot did license, VM Fiber storage you are that is now keep using wait will more VSAN deletions from Channel, a replace to first within your powerful Storage users switch class who array vsphere VMFS commit, have from cares? vmotion, and citizen thin been one ESX has plus VVols and day better take to your array possibly your ESXi visibility enjoying backups provides has time or from VM-level into automatically will a with unified storage complete vsphere it visibility storage Client faster to resources architecture Web Client? than across vsphere protocols has

10 VVol Replication Deep Dive

11 Introduction Array replication support via SPBM introduced in vsphere 6.5 (VASA 3.0) Nimble supported replication in vsphere 6.0 Nimble and 3PAR first to complete VVol replication implementations (before merger) Nimble and 3PAR were both VMware design partners on VVols 2.0 Replication done at the VVol level (VM) not the datastore level like SRM (LUN) Replication Groups automatically created on array contain VVol objects Designed to be managed in vsphere, not on array side

12 Components of VVol Replication Fault Domains [new] Something that fails as a whole (3PAR = storage array, Nimble = Nimble group) Replication Groups [new] Replicate VVol-based VMs between fault domains Groups maintain consistent point[s]-in-time 3PAR - Only maintains most recent point in time, which is no older than the most recent RPO Nimble Uses Volume Collections [most recent point for RGs] - plugin (workflows for replication) RPOs can be stretched when adding VMs or VVols to a replication group Groups are in a Source, Target, InTest or FailedOver state Terms Source/Primary/Protected are interchangeable Terms Target/Secondary/Recovery are interchangeable

13 VVol Replication diagram VVols Storage Container vsphere Storage Policy (SPBM) Replication Group Local Array (Fault Domain) Remote Array (Fault Domain)

14 Preparing for VVol Replication vsphere 3PAR Nimble vsphere 6.5 required Register VASA Provider Mount Storage Containers (VVol datastores) at primary and secondary sites Define Storage Policy with replication rules (Components) 3PAR OS required Remote Copy license Connect arrays via FC or iscsi Define remote targets for Remote Copy Create Storage Containers on primary and secondary arrays vsphere 6.0 or 6.5 NimbleOS required for VASA 3.0 No licenses required Configure source and destination as replication partners Create Folders (storage containers) on source and destination

15 Creating Nimble Folder / Storage Container Nimble folders are used for general organization Setting VVol management type makes it a Storage Container Must set a capacity limit Can optionally set a folder-level performance limit

16 Replication Storage Policies Summary Granular (per VM/Virtual Disk) Empowers vsphere admin No need to coordinate with Storage admin No need to involve Storage admin during disaster recovery Storage admin may need to do some clean-up after a true disaster New Component feature for SPBM allows Components to be defined once and re-used Replication Components contain rules and constraints related to array replication Components are attached to policies which are attached to VMs SPBM maintains compliance to ensure VM resides on storage that can meet policy definition

17 Example Storage Policy [3PAR] Target array & Storage Container Need only specify one replication constraint to enable VVol replication Target & Snapshot CPG drive tiers Remote Copy mode (Periodic only) Desired RPO Minutes (5 min) Where possible, other VVol capabilities (i.e. deduplication) are mirrored at remote site if remote array/cpg allows for it

18 Example Storage Policy [Nimble] Protection schedule by minute, hour, daily or weekly Can set local and remote snapshot retention policies Choose replication partner and frequency Option to delete replicas from partner when source deleted

19 Creating a new VM with replication Choose an existing Replication Group or Automatic

20 Changing a VM s Replication Policy Select VM Policies, Edit VM Storage Policies

21 Changing a VM s Replication Policy Selecting a Storage Policy with Replication Constraints

22 Changing a VM s Replication Policy Selecting either a common or per storage object Replication Group

23 Replication Groups on the Array s932 cli% showvvolvm -sc SanJoseContainer -rcopy (MB) VM_Name GuestOS VM_State Num_vv Physical Logical VMSanJose other26xlinux64guest Unbound TinyVM2 other26xlinux64guest Unbound TinyVM1 other26xlinux64guest Unbound TinyVM3 other26xlinux64guest Unbound VMFremont other26xlinux64guest Unbound total Output continued below RcopyStatus RcopyGroup RcopyRole RcopyLastSyncTime Synced VMSanJosgrp_3c12e41 Primary :20:00 PDT Synced TinyVM2grp_80ed051 Primary :22:00 PDT None NA Synced TinyVM3grp_1a3d5ba.r99931 Secondary :20:10 PDT Synced VMFremongrp_ca4027f.r99931 Secondary :21:10 PDT

24 3PAR SSMC User Interface VVol replication info - Remote Copy Group - Remote Copy Role - Remote Copy Status

25 Nimble Replication Groups

26 Disaster Recovery with VVols 26

27 vsphere Replication Components vcenter DR Orchestrator (PowerCLI) vcenter ESXi ESXi ESXi ESXi Protocol Endpoint VASA Provider Protocol Endpoint VASA Provider Remote Copy Protected Site VVol Storage Container Recovery Site

28 Types of Disaster Recovery operations Planned Failover Unplanned Failover Test Failover Controlled Typically used for disaster avoidance, planned maintenance or relocating VMs Can be per VM or all VMs Primary and recovery site reverse roles Uncontrolled Typically loss of power or hardware failure Not usually a per VM event, all VMs recovered Primary and recovery site reverse roles Controlled Typically used to validate VM recoverability Non-impactful Replica VMs cloned and made visible to vsphere at recovery site

29 Recovery and Cloning Nimble vcenter Plugin Snapshot based recovery Choose from all available snapshots Local VM Recovery In-place restore of VM Cloned as a new VM Local Virtual Disk Recovery In-place restore of virtual disk Cloned as a new disk to same VM Cloned as a new disk to different VM Remote VM Recovery Cloned as new VM at remote site No need to stop replication

30 Planned Failover Workflow with VVols Before Failover vcenter vsphere API PowerCLI vsphere API vcenter ESXi VM1 VM2 VM3 ESXi Source VVol Replica VVol Array Storage Container Source Replication Group Sw 1 C 1 D 1 Sn 1 C 2 D 2 Sw 2 Storage Container Target Replication Group C 1 D 1 Sn 1 C 2 D 2 Array C 3 D 3 C 3 D 3 Local Site Remote Site

31 Planned Failover Workflow with VVols Discover VM-to-group relationship (Get-SpbmReplicationGroup/Pair) vcenter vsphere API PowerCLI vsphere API vcenter ESXi VM1 VM2 VM3 ESXi C 1 C 2 C 1 C 2 Array D 1 Sn 1 D 2 D 1 Sn 1 D 2 Array Sw 1 Sw 2 C 3 D 3 C 3 D 3 Local Site Remote Site

32 Planned Failover Workflow with VVols Power down source VMs (stop-vm) vcenter vsphere API PowerCLI vsphere API vcenter ESXi VM1 VM2 VM3 ESXi C 1 C 2 C 1 C 2 Array D 1 Sn 1 D 2 D 1 Sn 1 D 2 Array Sw 1 Sw 2 C 3 D 3 C 3 D 3 Local Site Remote Site

33 Planned Failover Workflow with VVols Perform final sync (Sync-SpbmReplicationGroup) vcenter vsphere API PowerCLI vsphere API vcenter ESXi VM1 VM2 VM3 ESXi C 1 C 2 C 1 C 2 Array D 1 Sn 1 D 2 D 1 Sn 1 D 2 Array C 3 D 3 C 3 D 3 Local Site Remote Site

34 Planned Failover Workflow with VVols Issue a planned failover (Start-SpbmReplicationFailover) vcenter vsphere API PowerCLI vsphere API vcenter ESXi VM1 VM2 VM3 ESXi C 1 C 2 C 1 C 2 Array Source Replication Group D 1 Sn 1 D 2 Failed-over Target Replication Group D 1 Sn 1 D 2 Array C 3 D 3 C 3 D 3 Local Site Remote Site

35 Planned Failover Workflow with VVols Register newly-failed-over VMs (New-VM) vcenter vsphere API PowerCLI vsphere API vcenter ESXi VM1 VM2 VM1 VM2 VM3 ESXi C 1 C 2 C 1 C 2 Array Source Replication Group D 1 Sn 1 D 2 Failed-over Replication Group D 1 Sn 1 D 2 Array C 3 D 3 C 3 D 3 Local Site Remote Site

36 Planned Failover Workflow with VVols Apply an SPBM replication Policy to the VMs (Set-SpbmEntityConfiguration) vcenter vsphere API PowerCLI vsphere API Replication Policy vcenter ESXi VM1 VM2 VM1 VM2 VM3 ESXi C 1 C 2 C 1 C 2 Array Source Replication Group D 1 Sn 1 D 2 Failed-over Replication Group D 1 Sn 1 D 2 Array C 3 D 3 C 3 D 3 Local Site Remote Site

37 Planned Failover Workflow with VVols Unregister VMs at primary site (remove-vm) vcenter vsphere API PowerCLI vsphere API vcenter ESXi VM1 VM2 VM1 VM2 VM3 ESXi C 1 C 2 C 1 C 2 Array Source Replication Group D 1 Sn 1 D 2 Failed-over Replication Group D 1 Sn 1 D 2 Array C 3 D 3 C 3 D 3 Local Site Remote Site

38 Planned Failover Workflow with VVols Power up VMs at Failed-Over site (start-vm) vcenter vsphere API PowerCLI vsphere API vcenter ESXi VM1 VM2 VM3 ESXi C 1 C 2 C 1 C 2 Array Source Replication Group D 1 Sn 1 D 2 Failed-over Replication Group D 1 D 2 Sn 1 Sw 1 Sw 2 Array C 3 D 3 C 3 D 3 Local Site Remote Site

39 Planned Failover Workflow with VVols Power up VMs at Failed-Over site (Start-SpbmReplicationReverse) vcenter vsphere API PowerCLI vsphere API vcenter ESXi VM1 VM2 VM3 ESXi C 1 C 2 C 1 C 2 Array Source Target Replication Group D 1 Sn 1 D 2 Failed-over Source Replication Group D 1 D 2 Sn 1 Sw 1 Sw 2 Array C 3 D 3 C 3 D 3 Local Site Remote Site

40 Demo time! 40

41 Switch to 3PAR Replication unplanned failover demo Play STO3305BUS_Siebert_UnplannedFailover.mp4 (5:11) 41

42 Switch to Nimble Replication demo Play STO3305BUS_Siebert_NimbleDemo.mp4 (2:30) 42

43 Closing 43

44 The HPE 3PAR & Nimble advantage with VVOLs Solid and mature 6+ years of development VMware design partner Fibre Channel reference platform Simple and reliable Internal VASA Provider No external failure points Zero step installation Innovative and efficient Snapshots on different tiers Smallest capacity VM footprint Manage VVols folder by folder Rich and powerful App level optimized storage policies Architectures optimized for VVols VM Recovery directly from vcenter

45 Call To Action Find out more While at VMworld: Visit HPE Booth #600 to talk to our experts Check out HOL-1827 for some hands-on with Nimble VVols and replication Attend VVols Partner Panel session ID # Attend HPE in-booth VVol sessions Anytime: Stalk us Download DR scripts from github Bookmark Around The Storage Block blog 3PAR VVol Key docs: 3PAR VMware VVol Implementation Guide 3PAR VMware VVol Replication Guide Nimble VVol Key docs: VMware Integration Guide VMware vsphere 6 Deployment Considerations

46 Thank You

47 Backup slides 47

48 Two Primaries Window Summarize and simplify this During Planned and Unplanned failover a window exists when you have two source/primary replication groups During this time window, VMs changed as well as added/removed from replication groups, will require resolution when the groups are reversed. With traditional storage, any changes at the original source datastore are completely wiped out With VVols, it s possible to reverse some of the actions taken at the original source site. For example: A VM deleted at the primary is kept alive until the reverse-replication operation is performed. At which point, the VM is recovered, assuming it still exists at the new source site. Adding a new VM to the original source replication group will not be lost, but instead, auto-dismissed from the group when the reverse operation occurs. VM snapshots taken at the source replication group will be lost upon reversal. 48

49 Handling Conflicts with Two Primary Replication Groups Deleting a VM at the original source vcenter vsphere API PowerCLI vsphere API vcenter ESXi VM1 VM2 VM1 VM2 VM3 ESXi C 1 C 2 C 1 C 2 Array Source Replication Group D 1 Sn 1 D 2 Failed-over Replication Group D 1 Sn 1 D 2 Array C 3 D 3 C 3 D 3 Local Site Remote Site

50 Handling Conflicts with Two Primary Replication Groups Adding a VM to the original source after fail-over vcenter vsphere API PowerCLI vsphere API vcenter ESXi VM1 VM2 VM4 VM1 VM2 VM3 ESXi C 1 C 4 C 2 C 1 C 2 Array Source Replication Group D 1 D 4 Sn 1 D 2 Failedover Replication Group D 1 Sn 1 D 2 Array C 3 D 3 C 3 D 3 Local Site Remote Site

51 Planned Failover Workflow with VVols In-conflict VVols are automatically removed from the group, but not destroyed vcenter vsphere API PowerCLI vsphere API vcenter ESXi VM4 VM1 VM2 VM3 ESXi C 1 C 4 C 2 C 1 C 2 Array Source Target Replication Group D 1 D 4 Sn 1 D 2 C 4 D 4 Failed-over Source Replication Group D 1 Sn 1 D 2 Array C 3 D 3 C 3 D 3 Local Site Remote Site

52 Benefits of VVols on Nimble Storage Embedded VASA Provider No need to manage additional resources Highly available VASA Provider Management Automated registration of VP Automatic creation of PE and host access control management Folders Manage VVOLs folder by folder Folders can grow and shrink dynamically Backup and Recovery Replicate VM using array based replication Recover VM using Nimble vcenter Plugin

53 Nimble VVol Implementation Storage Policy Based Management New policy-based framework from VMware Foundation of VMware Software Defined Datacenter control pane Based on the VASA management protocol Nimble Policy Based Management Built-in application abstractions Pick from drop-down list - Exchange, SQL, VDI, Splunk, ESX etc. Auto-selects optimal storage settings Virtual Volumes Makes Nimble storage natively VM aware Enables virtual disk level offload of data services Snapshots, replication, encryption

54 Registering Nimble VASA Provider Done through Nimble Web UI Simply check the box 54

55 Additional SPBM Policy Options Application Policy Protection Schedule QoS / Performance Deduplication Data Encryption All-Flash

56 VVol Replication Objects VVol Storage Container Replication Group VVol Config, Data, RO/RW snapshots and k/v replicated. SWAP and storage policies not replicated Names of Storage Containers and CPGs shared shared between arrays Array A a.k.a Fault Domain Array B

57 Point-in-Time Snapshot for Failover Test [3PAR] VVol Replication Group Snapshot relationship C D C D C D VM1 RO VM1 RO VM1 RO Data & K/V C D C D C D VM2 RO VM2 RO VM2 RO VVol Datastore

58 3PAR VASA Replication Capabilities Built on top of HPE 3PAR Remote Copy rcopytargetcontainer Specifies the combined array sysname and Storage Container. Multiple values possible for each target sysname, one for each Storage Container at that target. Syntax: sysname:storagecontainername rcopymode Specifies requested remote copy mode. Periodic [only mode supported today for VVols] rcopyrpo Remote Copy itself supports synchronous, streaming and multi-target synchronous / periodic (SLD) Specifies periodic sync period. Range: (5min - 1 year) Requires rcopymode be set to Periodic

59 3PAR VASA Replication Capabilities Built on top of HPE 3PAR Remote Copy rcopyremotecpg Specifies the Provisioning Group (a.k.a CPG, a template for the volume physical characteristics, such RAID, and device type) to be used for remote copy at the target site for disk VVols. If not specified defaults to CPG capability, if specified. If not specified, VASA Provider selects a CPG. rcopyremotesnapcpg Specifies the CPG to be used for remote copy at the target site for base volumes One selectable from SPBM dropdown If not specified defaults to same as rcopyremotecpg capability Where possible, other VVol capabilities are mirrored at the remote site. For example, if deduplication is selected at the local site, a replica VVol on the remote array would be created with deduplication, if the remote array and remote CPG allow for it.

60 Disaster Recovery with VVol-based VMs Types of failover Planned Changes the responsibility for mastership of the VVol-based VMs from the Source/Primary site to the Target/Secondary site. Source and Target roles are reversed. Involves: Collecting replicated VM and group information at the Source and Target sites. Powering Down VMs at Source site Issuing a failover operation (Spbm-FailoverReplicationGroup in PowerCLI) Unregistering VMs at the source site Registering the VMs at the failover/target site. Applying a storage policy that allows replication back to the original Source site. Issuing a reverse operation (Spbm-ReverseReplicationGroup in PowerCLI) Optionally powering up the failed-over VMs 60

61 Disaster Recovery with VVol-based VMs Types of failover Unplanned Changes the responsibility for mastership of the VVol-based VMs from the Source/Primary site to the Target/Secondary site. Source and Target roles are reversed (eventually). When the disaster occurs: Collecting replicated group information at the Target/Recovery site Issuing a failover operation (Spbm-FailoverReplicationGroup in PowerCLI) Registering the VMs at the failover/target site. Applying a storage policy that allows replication back to the original Source site. Optionally powering up the failed-over VMs After the original Source site has recovered from it s disaster: Powering Down VMs at Source site (if needed) Unregistering VMs at the source site Issuing a reverse operation (Spbm-ReverseReplicationGroup in PowerCLI) There s no undo option. Once you issue a Planned or Unplanned failover, the only option is to continue forward. Issue a reverse, and optionally another failover and reverse to bring things back up at the original site. 61

62 Disaster Recovery with VVol-based VMs Types of failover Test Allows testing of replicated VVol-based VMs at the secondary site, by making copies of the replica VVols and exposing them to ESXi hosts for VM testing. Source and Target roles are NOT reversed. Involves: Collecting replicated VM and group information at the Source and Target sites. Issuing a test-failover operation (Start-SpbmReplicationTestFailover in PowerCLI) Registering the new test-vms at the target site. Applying a storage policy that allows replication back to the original Source site To help verify those replication policies are valid. Powering up, testing and powering down the in-test VMs Un-registering the test-vms Issuing a stop-test-failover operation (Stop-SpbmReplicationTestFailover in PowerCLI) Once the test is stopped, all VMs created by the test are destroyed permanently. 62

63 Storage Administrator s Responsibility after a Disaster [may remove this slide] Clean-up of automatically-created replication groups is automatic, unless a true disaster occurs. tbd 63

STO3305BES Replicating VMware VVols: A technical deep dive into VVol array based replication in vsphere 6.5 VMworld 2017 Claudio Calisto Storage Solutions Architect Nick Dyer Principal SE, Nimble Content:

More information

STO3305BUS Replicating VMware VVols: A Technical Deep Dive into VVol Array Based Replication in vsphere 6.5 Eric Siebert Solutions Manager Bob Neal-Joslin Software Architect Julian Cates Principal TME,

More information

Your World is Hybrid:

Your World is Hybrid: Your World is Hybrid: vsphere Virtual Volumes: The Time is Now Nick Dyer Principal Systems Engineer, UK A Brief History of 3PAR, Nimble & VMware VVols Design partnership between HPE and VMware Virtual

More information

Virtual Volumes FAQs First Published On: Last Updated On:

Virtual Volumes FAQs First Published On: Last Updated On: First Published On: 03-20-2017 Last Updated On: 07-13-2018 1 Table of Contents 1. FAQs 1.1.Introduction and General Information 1.2.Technical Support 1.3.Requirements and Capabilities 2 1. FAQs Frequently

More information

vsphere Virtual Volumes

vsphere Virtual Volumes vsphere Virtual Volumes Technical Overview Josh Atwell Andy Banta Special Thanks to Rawlinson Rivera and Cormac Hogan Presenters Josh Atwell Solutions Architect, SolidFire Andy Banta Storage Janitor, SolidFire

More information

Table of Contents HOL-PRT-1467

Table of Contents HOL-PRT-1467 Table of Contents Lab Overview - - Virtual Volumes with Dell EqualLogic... 2 Lab Guidance... 3 Pre-flight Instructions... 5 Module 1 - Working with Dell EqualLogic and VVOLs (60 Mins)... 11 Creating a

More information

Virtual Storage Console, VASA Provider, and Storage Replication Adapter for VMware vsphere

Virtual Storage Console, VASA Provider, and Storage Replication Adapter for VMware vsphere Virtual Storage Console, VASA Provider, and Storage Replication Adapter for VMware vsphere Workflow Guide for 7.2 release July 2018 215-13170_B0 doccomments@netapp.com Table of Contents 3 Contents Deciding

More information

shaping tomorrow with you Eternus VVOL Matthias Bothe Fujitsu Technology Solutions

shaping tomorrow with you Eternus VVOL Matthias Bothe Fujitsu Technology Solutions shaping tomorrow with you Eternus VVOL Matthias Bothe 0 2015 Fujitsu Technology Solutions Agenda What are Virtual Volumes? Advantages of VVOLs Technical implementation of VVOL for ETERNUS Usage 1 2015

More information

NexentaStor VVOL

NexentaStor VVOL NexentaStor 5.1.1 VVOL Admin Guide Date: January, 2018 Software Version: NexentaStor 5.1.1 VVOL Part Number: 3000-VVOL-5.1.1-000065-A Table of Contents Preface... 3 Intended Audience 3 References 3 Document

More information

Virtual Storage Console, VASA Provider, and Storage Replication Adapter for VMware vsphere

Virtual Storage Console, VASA Provider, and Storage Replication Adapter for VMware vsphere Virtual Storage Console, VASA Provider, and Storage Replication Adapter for VMware vsphere Administration Guide for 7.2 release June 2018 215-13169_A0 doccomments@netapp.com Table of Contents 3 Contents

More information

VMware vsphere 5.0 STORAGE-CENTRIC FEATURES AND INTEGRATION WITH EMC VNX PLATFORMS

VMware vsphere 5.0 STORAGE-CENTRIC FEATURES AND INTEGRATION WITH EMC VNX PLATFORMS VMware vsphere 5.0 STORAGE-CENTRIC FEATURES AND INTEGRATION WITH EMC VNX PLATFORMS A detailed overview of integration points and new storage features of vsphere 5.0 with EMC VNX platforms EMC Solutions

More information

vsphere Storage Update 1 Modified 16 JAN 2018 VMware vsphere 6.5 VMware ESXi 6.5 vcenter Server 6.5

vsphere Storage Update 1 Modified 16 JAN 2018 VMware vsphere 6.5 VMware ESXi 6.5 vcenter Server 6.5 Update 1 Modified 16 JAN 2018 VMware vsphere 6.5 VMware ESXi 6.5 vcenter Server 6.5 You can find the most up-to-date technical documentation on the VMware website at: https://docs.vmware.com/ If you have

More information

DELL EMC UNITY: VIRTUALIZATION INTEGRATION

DELL EMC UNITY: VIRTUALIZATION INTEGRATION DELL EMC UNITY: VIRTUALIZATION INTEGRATION A Detailed Review ABSTRACT This white paper introduces the virtualization features and integration points that are available on Dell EMC Unity. July, 2017 WHITE

More information

Virtual Storage Console, VASA Provider, and Storage Replication Adapter for VMware vsphere

Virtual Storage Console, VASA Provider, and Storage Replication Adapter for VMware vsphere Virtual Storage Console, VASA Provider, and Storage Replication Adapter for VMware vsphere Administration Guide for 7.1 release January 2018 215-12648_B0 doccomments@netapp.com Table of Contents 3 Contents

More information

iscsi Target Usage Guide December 15, 2017

iscsi Target Usage Guide December 15, 2017 December 15, 2017 1 Table of Contents 1. Native VMware Availability Options for vsan 1.1.Native VMware Availability Options for vsan 1.2.Application Clustering Solutions 1.3.Third party solutions 2. Security

More information

2014 VMware Inc. All rights reserved.

2014 VMware Inc. All rights reserved. 2014 VMware Inc. All rights reserved. Agenda Virtual SAN 1 Why VSAN Software Defined Storage 2 Introducing Virtual SAN 3 Hardware Requirements 4 DEMO 5 Questions 2 The Software-Defined Data Center Expand

More information

SC Series: Virtualization and Ecosystem Integrations. Darin Schmitz Storage Applications Engineering Midrange and Entry Solutions Group

SC Series: Virtualization and Ecosystem Integrations. Darin Schmitz Storage Applications Engineering Midrange and Entry Solutions Group SC Series: Virtualization and Ecosystem Integrations Darin Schmitz Storage Applications Engineering Midrange and Entry Solutions Group What s New with the SC Series New Dell EMC SC5020 Hybrid Array Optimized

More information

VMware vsphere 5.5 Professional Bootcamp

VMware vsphere 5.5 Professional Bootcamp VMware vsphere 5.5 Professional Bootcamp Course Overview Course Objectives Cont. VMware vsphere 5.5 Professional Bootcamp is our most popular proprietary 5 Day course with more hands-on labs (100+) and

More information

Data Protection Guide

Data Protection Guide SnapCenter Software 2.0 Data Protection Guide For Windows File Systems January 2017 215-11356_A0 doccomments@netapp.com Table of Contents 3 Contents Deciding whether to read this information... 5 SnapCenter

More information

Virtual Server Agent v9 with VMware. June 2011

Virtual Server Agent v9 with VMware. June 2011 Virtual Server Agent v9 with VMware June 2011 Contents Summary... 3 Backup Transport Methods... 3 Deployment Scenarios... 3 VSA Installation Requirements... 4 VSA Patch Requirements... 4 VDDK Installation...

More information

VMware vcenter Site Recovery Manager 4.1 Evaluator s Guide EVALUATOR'S GUIDE

VMware vcenter Site Recovery Manager 4.1 Evaluator s Guide EVALUATOR'S GUIDE VMware vcenter Site Recovery Manager 4.1 EVALUATOR'S GUIDE Table of Contents. Getting Started.... 3 About VMware vcenter Site Recovery Manager.... 3 About This Guide.... 3 Intended Audience.... 3 Assumptions....

More information

VPLEX & RECOVERPOINT CONTINUOUS DATA PROTECTION AND AVAILABILITY FOR YOUR MOST CRITICAL DATA IDAN KENTOR

VPLEX & RECOVERPOINT CONTINUOUS DATA PROTECTION AND AVAILABILITY FOR YOUR MOST CRITICAL DATA IDAN KENTOR 1 VPLEX & RECOVERPOINT CONTINUOUS DATA PROTECTION AND AVAILABILITY FOR YOUR MOST CRITICAL DATA IDAN KENTOR PRINCIPAL CORPORATE SYSTEMS ENGINEER RECOVERPOINT AND VPLEX 2 AGENDA VPLEX Overview RecoverPoint

More information

Data Protection Guide

Data Protection Guide SnapCenter Software 4.0 Data Protection Guide For VMs and Datastores using the SnapCenter Plug-in for VMware vsphere March 2018 215-12931_C0 doccomments@netapp.com Table of Contents 3 Contents Deciding

More information

VMware Exam VCP-511 VMware Certified Professional on vsphere 5 Version: 11.3 [ Total Questions: 288 ]

VMware Exam VCP-511 VMware Certified Professional on vsphere 5 Version: 11.3 [ Total Questions: 288 ] s@lm@n VMware Exam VCP-511 VMware Certified Professional on vsphere 5 Version: 11.3 [ Total Questions: 288 ] VMware VCP-511 : Practice Test Question No : 1 Click the Exhibit button. An administrator has

More information

Backup and Recovery Best Practices With Tintri VMstore

Backup and Recovery Best Practices With Tintri VMstore Backup and Recovery Best Practices With Tintri VMstore Backup and Recovery Best Practices with Tintri VMstore TECHNICAL BEST PRACTICES PAPER, Revision 1.0, April 10, 2014 Contents Contents Introduction

More information

The vsphere 6.0 Advantages Over Hyper- V

The vsphere 6.0 Advantages Over Hyper- V The Advantages Over Hyper- V The most trusted and complete virtualization platform SDDC Competitive Marketing 2015 Q2 VMware.com/go/PartnerCompete 2015 VMware Inc. All rights reserved. v3b The Most Trusted

More information

VMware vsphere Virtual Volumes for SolidFire Storage Configuration Guide

VMware vsphere Virtual Volumes for SolidFire Storage Configuration Guide Technical Report VMware vsphere Virtual Volumes for SolidFire Storage Aaron Patten and Andy Banta, NetApp October 2017 TR-4642 TABLE OF CONTENTS 1 Introduction... 4 1.1 Related Documents...4 2 Virtual

More information

Dell Storage vsphere Web Client Plugin. Version 4.0 Administrator s Guide

Dell Storage vsphere Web Client Plugin. Version 4.0 Administrator s Guide Dell Storage vsphere Web Client Plugin Version 4.0 Administrator s Guide Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make better use of your computer. CAUTION:

More information

VMware vsphere with ESX 6 and vcenter 6

VMware vsphere with ESX 6 and vcenter 6 VMware vsphere with ESX 6 and vcenter 6 Course VM-06 5 Days Instructor-led, Hands-on Course Description This class is a 5-day intense introduction to virtualization using VMware s immensely popular vsphere

More information

VMware vsphere Administration Training. Course Content

VMware vsphere Administration Training. Course Content VMware vsphere Administration Training Course Content Course Duration : 20 Days Class Duration : 3 hours per day (Including LAB Practical) Fast Track Course Duration : 10 Days Class Duration : 8 hours

More information

VMware vsphere on NetApp (VVNA)

VMware vsphere on NetApp (VVNA) VMware vsphere on NetApp (VVNA) COURSE OVERVIEW: Managing a vsphere storage virtualization environment requires knowledge of the features that exist between VMware and NetApp to handle large data workloads.

More information

EMC Integrated Infrastructure for VMware. Business Continuity

EMC Integrated Infrastructure for VMware. Business Continuity EMC Integrated Infrastructure for VMware Business Continuity Enabled by EMC Celerra and VMware vcenter Site Recovery Manager Reference Architecture Copyright 2009 EMC Corporation. All rights reserved.

More information

VMware vsphere: Fast Track [V6.7] (VWVSFT)

VMware vsphere: Fast Track [V6.7] (VWVSFT) VMware vsphere: Fast Track [V6.7] (VWVSFT) Formato do curso: Presencial Preço: 3950 Nível: Avançado Duração: 50 horas This five-day, intensive course takes you from introductory to advanced VMware vsphere

More information

FUJITSU Storage ETERNUS AF series and ETERNUS DX S4/S3 series

FUJITSU Storage ETERNUS AF series and ETERNUS DX S4/S3 series Utilizing VMware vsphere Virtual Volumes (VVOL) with the FUJITSU Storage ETERNUS AF series and ETERNUS DX S4/S3 series Reference Architecture for Virtual Platforms (15VM/iSCSI) The ETERNUS AF series and

More information

Using VMware vsphere Replication. vsphere Replication 6.5

Using VMware vsphere Replication. vsphere Replication 6.5 Using VMware vsphere Replication 6.5 You can find the most up-to-date technical documentation on the VMware website at: https://docs.vmware.com/ If you have comments about this documentation, submit your

More information

VMware vsphere with ESX 4.1 and vcenter 4.1

VMware vsphere with ESX 4.1 and vcenter 4.1 QWERTYUIOP{ Overview VMware vsphere with ESX 4.1 and vcenter 4.1 This powerful 5-day class is an intense introduction to virtualization using VMware s vsphere 4.1 including VMware ESX 4.1 and vcenter.

More information

NexentaStor Storage Replication Adapter User Guide

NexentaStor Storage Replication Adapter User Guide NexentaStor 5.1.1 Storage Replication Adapter User Guide Date: January, 2018 Part Number: 3000-nxs-SRA-User-Guide-5.1.1-000092-A Copyright 2018 Nexenta Systems TM, ALL RIGHTS RESERVED Notice: No part of

More information

XtremIO Business Continuity & Disaster Recovery. Aharon Blitzer & Marco Abela XtremIO Product Management

XtremIO Business Continuity & Disaster Recovery. Aharon Blitzer & Marco Abela XtremIO Product Management XtremIO Business Continuity & Disaster Recovery Aharon Blitzer & Marco Abela XtremIO Product Management Agenda XtremIO Current BC/DR Offerings New BC/DR Offering Benefits of New Offering Technical Overview

More information

VMware - VMware vsphere: Install, Configure, Manage [V6.7]

VMware - VMware vsphere: Install, Configure, Manage [V6.7] VMware - VMware vsphere: Install, Configure, Manage [V6.7] Code: Length: URL: EDU-VSICM67 5 days View Online This five-day course features intensive hands-on training that focuses on installing, configuring,

More information

VMware Virtual SAN. Technical Walkthrough. Massimiliano Moschini Brand Specialist VCI - vexpert VMware Inc. All rights reserved.

VMware Virtual SAN. Technical Walkthrough. Massimiliano Moschini Brand Specialist VCI - vexpert VMware Inc. All rights reserved. VMware Virtual SAN Technical Walkthrough Massimiliano Moschini Brand Specialist VCI - vexpert 2014 VMware Inc. All rights reserved. VMware Storage Innovations VI 3.x VMFS Snapshots Storage vmotion NAS

More information

HPE Synergy HPE SimpliVity 380

HPE Synergy HPE SimpliVity 380 HPE Synergy HPE SimpliVity 0 Pascal.Moens@hpe.com, Solutions Architect Technical Partner Lead February 0 HPE Synergy Composable infrastructure at HPE CPU Memory Local Storage LAN I/O SAN I/O Power Cooling

More information

Detail the learning environment, remote access labs and course timings

Detail the learning environment, remote access labs and course timings Course Duration: 4 days Course Description This course has been designed as an Introduction to VMware for IT Professionals, but assumes that some labs have already been developed, with time always at a

More information

Data Protection Guide

Data Protection Guide SnapCenter Software 3.0 Data Protection Guide For Windows File Systems July 2017 215-12097_A0 doccomments@netapp.com Table of Contents 3 Contents Deciding whether to read this information... 5 SnapCenter

More information

Dell SC Series Integration with VMware VVols

Dell SC Series Integration with VMware VVols Dell SC Series Integration with VMware VVols Dell Storage Hands-on Lab Estimated completion time: 30 minutes Audience The audience for this document includes technical professionals who wish to learn about

More information

Tech Note: vsphere Replication with vsan First Published On: Last Updated On:

Tech Note: vsphere Replication with vsan First Published On: Last Updated On: Tech Note: vsphere Replication with vsan First Published On: 10-27-2017 Last Updated On: 11-01-2017 1 Table of Contents 1. Introduction 1.1.Introduction 2. vsphere Replication with vsan Datastores 2.1.vSphere

More information

VMware vsphere Customized Corporate Agenda

VMware vsphere Customized Corporate Agenda VMware vsphere Customized Corporate Agenda It's not just VMware Install, Manage, Configure (Usual VCP Course). For working professionals, just VCP is not enough, below is the custom agenda. At the outset,

More information

IA L16 - Hands-On Lab Hands on with Instant Backup and Recovery Features of NetBackup 7.6 for VMware

IA L16 - Hands-On Lab Hands on with Instant Backup and Recovery Features of NetBackup 7.6 for VMware IA L16 - Hands-On Lab Hands on with Instant Backup and Recovery Features of NetBackup 7.6 for VMware Description NetBackup 7.6 offers terrific new technologies that provide faster VMware backups and restores

More information

Disaster Recovery-to-the- Cloud Best Practices

Disaster Recovery-to-the- Cloud Best Practices Disaster Recovery-to-the- Cloud Best Practices HOW TO EFFECTIVELY CONFIGURE YOUR OWN SELF-MANAGED RECOVERY PLANS AND THE REPLICATION OF CRITICAL VMWARE VIRTUAL MACHINES FROM ON-PREMISES TO A CLOUD SERVICE

More information

VMWARE VSPHERE: FAST TRACK V6.7 (EDU-VSFT67)

VMWARE VSPHERE: FAST TRACK V6.7 (EDU-VSFT67) VMWARE VSPHERE: FAST TRACK V6.7 (EDU-VSFT67) Dauer: 5 Tage Durchführungsart: Präsenztraining Nr.: 59444 Preis: 4.550,00 (netto) / 5.414,50 inkl. 19% MwSt. Zielgruppe: System Administrators System engineers

More information

Administering VMware vsphere and vcenter 5

Administering VMware vsphere and vcenter 5 Administering VMware vsphere and vcenter 5 Course VM-05 5 Days Instructor-led, Hands-on Course Description This 5-day class will teach you how to master your VMware virtual environment. From installation,

More information

Virtual Server Agent for VMware VMware VADP Virtualization Architecture

Virtual Server Agent for VMware VMware VADP Virtualization Architecture Virtual Server Agent for VMware VMware VADP Virtualization Architecture Published On: 11/19/2013 V10 Service Pack 4A Page 1 of 18 VMware VADP Virtualization Architecture - Virtual Server Agent for VMware

More information

VMware vcenter Site Recovery Manager 5 Technical

VMware vcenter Site Recovery Manager 5 Technical VMware vcenter Site Recovery Manager 5 Technical Jeff Hunter, VCAP-DCD Senior Systems Engineer BC/DR Specialist VMware, Inc. jhunter@vmware.com 2009 VMware Inc. All rights reserved Top IT Goals for Virtualization

More information

Dell EMC Unity Family

Dell EMC Unity Family Dell EMC Unity Family Version 4.3 Configuring VVols H14975 REV 04 Copyright 2016-2018 Dell Inc. or its subsidiaries. All rights reserved. Published January 2018 Dell believes the information in this publication

More information

VMWARE PROTECTION WITH DELL EMC NETWORKER 9

VMWARE PROTECTION WITH DELL EMC NETWORKER 9 VMWARE PROTECTION WITH DELL EMC NETWORKER 9 Solution Overview ABSTRACT This white paper describes the integration of Dell EMC NetWorker with VMware vcenter. It also includes details on the NetWorker architecture

More information

Disclaimer This presentation may contain product features that are currently under development. This overview of new technology represents no commitme

Disclaimer This presentation may contain product features that are currently under development. This overview of new technology represents no commitme SER1143BU A Deep Dive into vsphere 6.5 Core Storage Features and Functionality Cormac Hogan Cody Hosterman VMworld 2017 Content: Not for publication #VMworld #SER1143BU Disclaimer This presentation may

More information

IT Challenges - DC Track

IT Challenges - DC Track IT Challenges - DC Track Hyperconverged infrastructure : architecture of the datacenter for the future Stefan Verbist VMware Territory SE sverbist@vmware.com 2014 VMware Inc. All rights reserved. The Convergence

More information

vsan Disaster Recovery November 19, 2017

vsan Disaster Recovery November 19, 2017 November 19, 2017 1 Table of Contents 1. Disaster Recovery 1.1.Overview 1.2.vSAN Stretched Clusters and Site Recovery Manager 1.3.vSAN Performance 1.4.Summary 2 1. Disaster Recovery According to the United

More information

Introduction to Virtualization. From NDG In partnership with VMware IT Academy

Introduction to Virtualization. From NDG In partnership with VMware IT Academy Introduction to Virtualization From NDG In partnership with VMware IT Academy www.vmware.com/go/academy Why learn virtualization? Modern computing is more efficient due to virtualization Virtualization

More information

SRM Evaluation Guide First Published On: Last Updated On:

SRM Evaluation Guide First Published On: Last Updated On: First Published On: 12-24-2016 Last Updated On: 04-17-2018 1 Table of Contents 1. Introduction 1.1.Overview 1.2.Terminology 1.3.About This Evaluation Guide 2. Requirements 2.1.Overview 3. Evaluation Workflow

More information

Next Gen Storage StoreVirtual Alex Wilson Solutions Architect

Next Gen Storage StoreVirtual Alex Wilson Solutions Architect Next Gen Storage StoreVirtual 3200 Alex Wilson Solutions Architect NEW HPE StoreVirtual 3200 Storage Low-cost, next-gen storage that scales with you Start at < 5K* and add flash when you are ready Supercharge

More information

VI3 to vsphere 4.0 Upgrade and New Technology Ultimate Bootcamp

VI3 to vsphere 4.0 Upgrade and New Technology Ultimate Bootcamp VI3 to vsphere 4.0 Upgrade and New Technology Ultimate Bootcamp Course Length: 2 Days Course Overview This instructor-led course covers everything the student needs to know to upgrade from VMware 3.x to

More information

Data Protection Guide

Data Protection Guide SnapCenter Software 4.1 Data Protection Guide For VMs and Datastores using the SnapCenter Plug-in for VMware vsphere September 2018 215-13399_B0 doccomments@netapp.com Table of Contents 3 Contents Deciding

More information

Virtualized Storage for VMware Virtual Infrastructure. Presented by: John Martin Consulting Systems Engineer, NetApp

Virtualized Storage for VMware Virtual Infrastructure. Presented by: John Martin Consulting Systems Engineer, NetApp Virtualized Storage for VMware Virtual Infrastructure. Presented by: John Martin Consulting Systems Engineer, Net What If You Could... Backup and restore your VMs instantaneously Easily protect all your

More information

VMware vsphere 6.5/6.0 Ultimate Bootcamp

VMware vsphere 6.5/6.0 Ultimate Bootcamp VMware vsphere 6.5/6.0 Ultimate Bootcamp Class Duration 5 Days Introduction This fast paced, high energy, hands-on course provides not only the foundation needed for a top performing software defined datacenter

More information

StorageCraft OneXafe and Veeam 9.5

StorageCraft OneXafe and Veeam 9.5 TECHNICAL DEPLOYMENT GUIDE NOV 2018 StorageCraft OneXafe and Veeam 9.5 Expert Deployment Guide Overview StorageCraft, with its scale-out storage solution OneXafe, compliments Veeam to create a differentiated

More information

Disclaimer This presentation may contain product features that are currently under development. This overview of new technology represents no commitme

Disclaimer This presentation may contain product features that are currently under development. This overview of new technology represents no commitme SER2779BE What s New in vcenter Server Madhup Gulati Director, Product Management VMware VMworld 2017 Content: Not for publication #VMworld #SER2779BE Disclaimer This presentation may contain product features

More information

Vurtualised Storage for VMware Virtual Infrastructures. Presented by: Rob Waite Consulting Systems Engineer, NetApp

Vurtualised Storage for VMware Virtual Infrastructures. Presented by: Rob Waite Consulting Systems Engineer, NetApp Vurtualised Storage for VMware Virtual Infrastructures Presented by: Rob Waite Consulting Systems Engineer, Net Virtualised Storage for VMware Virtual Infrastructures Rob Waite, VCP Consulting Systems

More information

VMware vsphere APIs for I/O Filtering (VAIO) November 14, 2017

VMware vsphere APIs for I/O Filtering (VAIO) November 14, 2017 VMware vsphere APIs for I/O Filtering (VAIO) November 14, 2017 1 Table of Contents 1. Introduction to vsphere APIs for I/O Filtering 1.1.Introduction to vsphere APIs for I/O Filtering 2. VAIO Technical

More information

Exam4Tests. Latest exam questions & answers help you to pass IT exam test easily

Exam4Tests.   Latest exam questions & answers help you to pass IT exam test easily Exam4Tests http://www.exam4tests.com Latest exam questions & answers help you to pass IT exam test easily Exam : VCP510PSE Title : VMware Certified Professional 5 - Data Center Virtualization PSE Vendor

More information

[VMICMV6.5]: VMware vsphere: Install, Configure, Manage [V6.5]

[VMICMV6.5]: VMware vsphere: Install, Configure, Manage [V6.5] [VMICMV6.5]: VMware vsphere: Install, Configure, Manage [V6.5] Length Delivery Method : 5 Days : Instructor-led (Classroom) Course Overview This five-day course features intensive hands-on training that

More information

SRM 8.1 Technical Overview First Published On: Last Updated On:

SRM 8.1 Technical Overview First Published On: Last Updated On: First Published On: 12-23-2016 Last Updated On: 04-17-2018 1 Table of Contents 1. Introduction 1.1.Overview 1.2.Terminology 2. Architectural Overview 2.1.Overview 3. Use Cases 3.1.Overview 3.2.Disaster

More information

VMware vsphere 5.5 Advanced Administration

VMware vsphere 5.5 Advanced Administration Format 4-day instructor led training Course Books 630+ pg Study Guide with slide notes 180+ pg Lab Guide with detailed steps for completing labs vsphere Version This class covers VMware vsphere 5.5 including

More information

Disclaimer This presentation may contain product features that are currently under development. This overview of new technology represents no commitme

Disclaimer This presentation may contain product features that are currently under development. This overview of new technology represents no commitme STO1297BE Stretched Clusters or VMware Site Recovery Manager? We Say Both! Jeff Hunter, VMware, @jhuntervmware GS Khalsa, VMware, @gurusimran #VMworld Disclaimer This presentation may contain product features

More information

Dell EMC SC Series Virtual Volumes Best Practices

Dell EMC SC Series Virtual Volumes Best Practices Dell EMC SC Series Virtual Volumes Best Practices Abstract Best practices for deploying and configuring VMware vsphere Virtual Volumes with Dell EMC SC Series storage. September 2017 Dell EMC Best Practices

More information

VMware vsphere 6.5: Install, Configure, Manage (5 Days)

VMware vsphere 6.5: Install, Configure, Manage (5 Days) www.peaklearningllc.com VMware vsphere 6.5: Install, Configure, Manage (5 Days) Introduction This five-day course features intensive hands-on training that focuses on installing, configuring, and managing

More information

VMware Backup and Replication using Vembu VMBackup

VMware Backup and Replication using Vembu VMBackup VMware Backup and Replication using Vembu VEMBU TECHNOLOGIES PARTNERS Vembu Technologies Founded in 2002 10+ Years of Experience Headquartered in Chennai 100+ Countries 4000+ Partners 2 60000+ Businesses

More information

VMware vsphere with ESX 4 and vcenter

VMware vsphere with ESX 4 and vcenter VMware vsphere with ESX 4 and vcenter This class is a 5-day intense introduction to virtualization using VMware s immensely popular vsphere suite including VMware ESX 4 and vcenter. Assuming no prior virtualization

More information

Changes in VCP6.5-DCV exam blueprint vs VCP6

Changes in VCP6.5-DCV exam blueprint vs VCP6 Changes in VCP6.5-DCV exam blueprint vs VCP6 Blueprint Objective Blueprint Changes Blueprint Additions Associated v6.5 Technology Changes 1.1 Changed objective from: VMware Directory Service VMware Identity

More information

Vendor: VMware. Exam Code: VCAD510. Exam Name: VMware Certified Associate Data Center Virtualization (VCA-DCV) Exam. Version: Demo

Vendor: VMware. Exam Code: VCAD510. Exam Name: VMware Certified Associate Data Center Virtualization (VCA-DCV) Exam. Version: Demo Vendor: VMware Exam Code: VCAD510 Exam Name: VMware Certified Associate Data Center Virtualization (VCA-DCV) Exam Version: Demo QUESTION 1 You work for a convenience store chain that has a full data center

More information

VMware vsphere: Fast Track. System administrators System engineers. Cursusduur: 5 Dagen Cursuscode: VSFT Version: 6.7. Beschrijving: Doelgroep:

VMware vsphere: Fast Track. System administrators System engineers. Cursusduur: 5 Dagen Cursuscode: VSFT Version: 6.7. Beschrijving: Doelgroep: VMware vsphere: Fast Track Cursusduur: 5 Dagen Cursuscode: VSFT Version: 6.7 Beschrijving: This five-day, intensive course takes you from introductory to advanced VMware vsphere management skills. Building

More information

SnapCenter Software 4.0 Concepts Guide

SnapCenter Software 4.0 Concepts Guide SnapCenter Software 4.0 Concepts Guide May 2018 215-12925_D0 doccomments@netapp.com Table of Contents 3 Contents Deciding whether to use the Concepts Guide... 7 SnapCenter overview... 8 SnapCenter architecture...

More information

VMware vsphere: Install, Configure, Manage plus Optimize and Scale- V 6.5. VMware vsphere 6.5 VMware vcenter 6.5 VMware ESXi 6.

VMware vsphere: Install, Configure, Manage plus Optimize and Scale- V 6.5. VMware vsphere 6.5 VMware vcenter 6.5 VMware ESXi 6. VMware vsphere V 6.5 VMware vsphere: Install, Configure, Manage plus Optimize and Scale- V 6.5 vsphere VMware vsphere 6.5 VMware vcenter 6.5 VMware ESXi 6.5 VMware vsphere vcenter ESXi ESXi VMware vcenter

More information

Soluzioni integrate con vsphere La virtualizzazione abilita il percorso evolutivo di innovazione dell'it

Soluzioni integrate con vsphere La virtualizzazione abilita il percorso evolutivo di innovazione dell'it Soluzioni integrate con vsphere La virtualizzazione abilita il percorso evolutivo di innovazione dell'it Matteo Montuori Systems Engineer, VMware mmontuori@vmware.com 2010 VMware Inc. All rights reserved

More information

Dell EMC Unity: Data Protection & Copy Data Management Options. Ryan Poulin Product Technologist Midrange & Entry Solutions Group

Dell EMC Unity: Data Protection & Copy Data Management Options. Ryan Poulin Product Technologist Midrange & Entry Solutions Group Dell EMC Unity: Data Protection & Copy Data Management Options Ryan Poulin Product Technologist Midrange & Entry Solutions Group What s New with Dell EMC Unity 650F 550F 450F 350F Optimized for All-Flash

More information

Nutanix White Paper. Hyper-Converged Infrastructure for Enterprise Applications. Version 1.0 March Enterprise Applications on Nutanix

Nutanix White Paper. Hyper-Converged Infrastructure for Enterprise Applications. Version 1.0 March Enterprise Applications on Nutanix Nutanix White Paper Hyper-Converged Infrastructure for Enterprise Applications Version 1.0 March 2015 1 The Journey to Hyper-Converged Infrastructure The combination of hyper-convergence and web-scale

More information

Veeam Backup & Replication Version 6.0

Veeam Backup & Replication Version 6.0 Veeam Backup & Replication Version 6.0 Evaluator s Guide VMware Environments March, 2012 2012 Veeam Software. All rights reserved. All trademarks are the property of their respective owners. No part of

More information

Microsoft SQL Server HA and DR with DVX

Microsoft SQL Server HA and DR with DVX Microsoft SQL Server HA and DR with DVX 385 Moffett Park Dr. Sunnyvale, CA 94089 844-478-8349 www.datrium.com Technical Report Introduction A Datrium DVX solution allows you to start small and scale out.

More information

SC Series: Affordable Data Mobility & Business Continuity With Multi-Array Federation

SC Series: Affordable Data Mobility & Business Continuity With Multi-Array Federation SC Series: Affordable Data Mobility & Business Continuity With Multi-Array Federation Jason Boche Storage Applications Engineering Midrange & Entry Level Solutions What s New with the SC Series New Dell

More information

EMC Business Continuity for Microsoft Applications

EMC Business Continuity for Microsoft Applications EMC Business Continuity for Microsoft Applications Enabled by EMC Celerra, EMC MirrorView/A, EMC Celerra Replicator, VMware Site Recovery Manager, and VMware vsphere 4 Copyright 2009 EMC Corporation. All

More information

2V0-620 Exam Questions Demo VMware. Exam Questions 2V vsphere 6 Foundations Beta Exam

2V0-620 Exam Questions Demo   VMware. Exam Questions 2V vsphere 6 Foundations Beta Exam VMware Exam Questions 2V0-620 vsphere 6 Foundations Beta Exam Version:Demo 1. What are two possible causes of Storage Distributed Resource Scheduler (SDRS) being disabled on one or more virtual machine

More information

Windows Server 2012 Hands- On Camp. Learn What s Hot and New in Windows Server 2012!

Windows Server 2012 Hands- On Camp. Learn What s Hot and New in Windows Server 2012! Windows Server 2012 Hands- On Camp Learn What s Hot and New in Windows Server 2012! Your Facilitator Damir Bersinic Datacenter Solutions Specialist Microsoft Canada Inc. damirb@microsoft.com Twitter: @DamirB

More information

Data Protection Guide

Data Protection Guide SnapCenter Software 1.1 Data Protection Guide For Oracle Databases May 2016 215-10972_C0 doccomments@netapp.com Table of Contents 3 Contents Data protection using SnapCenter Plug-in for Oracle Database...

More information

Overview. Prerequisites. VMware vsphere 6.5 Optimize, Upgrade, Troubleshoot

Overview. Prerequisites. VMware vsphere 6.5 Optimize, Upgrade, Troubleshoot VMware vsphere 6.5 Optimize, Upgrade, Troubleshoot Course Name Format Course Books vsphere Version Delivery Options Remote Labs Max Attendees Requirements Lab Time Availability May, 2017 Suggested Price

More information

VMware vsphere VMFS First Published On: Last Updated On:

VMware vsphere VMFS First Published On: Last Updated On: First Published On: 10-24-2017 Last Updated On: 10-24-2017 1 Table of Contents 1. Introduction 1.1.Introduction 2. Background 2.1.Background 3. VMFS Technical Overview 3.1.VMFS Technical Overview 4. Features

More information

Disclaimer This presentation may contain product features that are currently under development. This overview of new technology represents no commitme

Disclaimer This presentation may contain product features that are currently under development. This overview of new technology represents no commitme STO1794BE Evolution of vsan Vijay Ramachandran Sr.Director, Product Management Christos Karamanolis VMware Fellow & CTO of Storage & Availability #VMworld #STO1794BE Disclaimer This presentation may contain

More information

Potpuna virtualizacija od servera do desktopa. Saša Hederić Senior Systems Engineer VMware Inc.

Potpuna virtualizacija od servera do desktopa. Saša Hederić Senior Systems Engineer VMware Inc. Potpuna virtualizacija od servera do desktopa Saša Hederić Senior Systems Engineer VMware Inc. VMware ESX: Even More Reliable than a Mainframe! 2 The Problem Where the IT Budget Goes 5% Infrastructure

More information

Redefine Data Protection: Next Generation Backup And Business Continuity

Redefine Data Protection: Next Generation Backup And Business Continuity Redefine Data Protection: Next Generation Backup And Business Continuity 1 Business Is Being Redefined Leveraging the Power of Technology Megatrends CLOUD MOBILE SOCIAL BIG DATA 2 Creating New Next Gen

More information

vrealize Suite 6.0 Disaster Recovery by Using Site Recovery Manager 5.8

vrealize Suite 6.0 Disaster Recovery by Using Site Recovery Manager 5.8 vrealize Suite 6.0 Disaster Recovery by Using Site Recovery Manager 5.8 vrealize Suite 6.0 This document supports the version of each product listed and supports all subsequent versions until the document

More information

VMware vsphere: Install, Configure, Manage (vsphere ICM 6.7)

VMware vsphere: Install, Configure, Manage (vsphere ICM 6.7) VMware vsphere: Install, Configure, Manage (vsphere ICM 6.7) COURSE OVERVIEW: This five-day course features intensive hands-on training that focuses on installing, configuring, and managing VMware vsphere

More information

Introducing Tegile. Company Overview. Product Overview. Solutions & Use Cases. Partnering with Tegile

Introducing Tegile. Company Overview. Product Overview. Solutions & Use Cases. Partnering with Tegile Tegile Systems 1 Introducing Tegile Company Overview Product Overview Solutions & Use Cases Partnering with Tegile 2 Company Overview Company Overview Te gile - [tey-jile] Tegile = technology + agile Founded

More information