NS0-171.network appliance
|
|
- Bethanie Dawson
- 5 years ago
- Views:
Transcription
1 NS0-171.network appliance Number: NS0-171 Passing Score: 800 Time Limit: 120 min
2 Exam A QUESTION 1 An administrator is deploying a FlexPod solution for use with VMware vsphere 6.0. The storage environment consists of a two-node AFF8040 cluster running clustered Data ONTAP 8.3 with a single DS2246 disk shelf fully populated with 800 GB SSD drives. The system is configured to use Advanced Drive Partitioning (ADP). The administrator wants to ensure that each node is configured with the same amount of recourses while also using hot spares for resiliency. In this scenario, how many total disk partitions will each node have available for the data aggregate? A. 12 B. 8 C. 11 D. 22 Correct Answer: B QUESTION 2 You are asked to configure the computer resources in a FlexPod solution to ensure that jumbo frames are configured end-to-end. Which three actions must you perform to accomplish this task? (Choose three.) A. Set the MTU size to 1500 on the vnic template B. Enable jumbo frames on all of the switches between the initiator and the isci target. C. Configure a UCS QoS System Class with the jumbo frames. D. Configure jumbo frames on the switch VLANs. E. Enable jumbo frames on the operating system adapter. Correct Answer: BCE
3 Reference QUESTION 3 The NetApp Vistual Storage Console is used to set which three setting categories on ESXi hosts? (Choose three.) A. MPIO Settings B. Adapter Settings C. Logging Settings D. NFS Settings E. Security Settings Correct Answer: ABD Reference QUESTION 4 A server administrator calls you complaining that an uplink on both UCS Fabric Interconnects went down. Each Fabric Interconnect has a vpc to the Nexus 500 switches. After logging in to the switches, you notice that all vpc member ports on the secondary vpc peer switch are down. The vpc peer keepalive is still operational. What is the problem in this scenario? A. The vpc peer link is down. B. Both UCS Fabric Interconnects rebooted. C. The vpc feature is disabled. D. A new VLAN was added to the UCS vpc member ports. Correct Answer: A
4 QUESTION 5 An administrator has a FlexPod solution with VMware vsphere. The administrator is migrating all network traffic from standard switches to vsphere distributed switches. Virtual machines (VMs) are currently using VM port groups called VLAN_500 and VLAN_501 on standard virtual switch vswitch3. A new distributed switch called dvswitch_vm is created and new distributed port groups are configured for each VM traffic VLAN. VMs are configured to use the new port groups. After the change, VMs on VLAN 501 report a loss of network connectivity; however, VMs on VLAN 500 are not showing any connectivity issues. The symptoms are experienced for VMs on all ESXi hosts. Which action must the administrator perform to solve the problem? A. Reboot the virtual machines to re-establish network connectivity. B. Create a new vmkernel port on dvswitch_vm for VLAN 501. C. Configure the dvswitch_vm port binding to Ephemeral. D. Add the correct VLAN ID to the new distributed port group for VLAN 501. Correct Answer: C QUESTION 6 Which two database types are supported with the VMWare vcenter 6.0 Server Appliance? (Choose two.) A. Oracle B. vpostgres (embedded) C. Microsoft SQL Server Express D. Microsoft SQL Server Enterprise Correct Answer: AB Reference QUESTION 7 Which three actions are required to configure two Cisco Nexus switches as vpc peers? (Choose three.)
5 A. Enable the vpc feature. B. Configure matching vpc domain IDs. C. Create a peer link between switches. D. Configure different vpc domain IDs for each switch. E. Modify the network QoS policy. Correct Answer: BCE QUESTION 8 Click the Exhibit button.
6 You have FCoE configured between your Nexus 5672UP switches and UCS Fabric Interconnects running in FC end-host mode. You are experiencing disk I/O errors on your VMware FCoE datastore, but the NFS datastores on the same NetApp storage system are not experiencing any problems. Referring to the Nexus output shown in the exhibit, what would cause this problem? A. Port flow-control is currently off. B. The no-drop QoS classes on the Fabric Interconnects are different than those on the Nexus switches. C. The FCoE uplinks from the Fabric Interconnects must use the ports on the far right side of the Nexus switches. D. VL bmap is hard to set to off. Correct Answer: B
7 QUESTION 9 Click the Exhibit button. Which Cisco switch is shown in the exhibit? A. Nexus 2232 B. Nexus 5548 C. Nexus 5596 D. Nexus 7004 Correct Answer: B QUESTION 10 Which two technologies must be deployed for a Cisco Nexus 9000 ACI design? (Choose two.) A. spine switch B. VSM C. APIC D. LACP Correct Answer: AC
8 Reference QUESTION 11 Your customer has the storage configuration for a FlexPod solution shown below. --FAS8040 HA-pair --Disk stack one-4x DS4243 disk shelves (2TB SATA disk drives) --Disk stack two- 2x DS 2246 disk shelves (1.2TB disk drives) --There are no unused SAS ports on either controller --There are no expansion slots available on either controller The customer wants to attach a single DS2246 disk shelf with 800 GB SSD drives. In this scenario, what are two ways to connect the new shelf for optimal performance? (Choose two). A. Cable the new shelf to the end of stack one. B. Cable the new shelf to the end of stack two. C. Cable a new stack for the SSD shelf. D. Cable the new shelf to the beginning of stack two. Correct Answer: CD QUESTION 12 Which type of pools do you need to create vhba templates? A. MAC B. WWNN C. IQN D. WWPN Correct Answer: D
9 Reference UCSM_GUI_Configuration_Guide_141_chapter28.html#task_8F07617D52184F6D FF849DA9 QUESTION 13 Click the Exhibit button.
10
11 An iscsi SAN boot is not working for a new Cisoc UCS service profile. The new vnic template was created using the settings shown in the exhibit. What should you do to make iscsi SAN boot work? A. Specify a QoS policy. B. Change the MAC pool to <not set>. C. Set the iscsi-a-vlan as the Native VLAN. D. Change the vnic template to type Initial Template. Correct Answer: A QUESTION 14 Which two operating modes are available with the Nexus 9000 Series switches? (Choose two.) A. Cisco NX-OS B. Cisco ACI C. Cisco IOS D. Cisco IOS EX Correct Answer: AB Reference QUESTION 15
12 You have a FlexPod solution with Cisco 6296UP Fabric Interconnects. You currently have a direct-attached AFF8040 system using FCoE for storage connectivity. You would like to reconfigure the FlexPod so that the storage is connected through the upstream switches. Using UCS Manager, which two steps would you perform to accomplish this task? (Choose two.) A. Using the Configure Unified Ports wizard, change the port types to Ethernet. B. Using the Configure Unified Ports wizard, change the port types to FC. C. Configure the FI ports with the FCoE Uplink role. D. Configure the FI ports with the Uplink role. Correct Answer: BD QUESTION 16 You want to verify that you have configured Multipath HA correctly for all of the attached disk shelves on a NetApp cluster. Which two commands would you execute from the cluster CLI prompt to accomplish this task? (Choose two.) A. sysconfig -a B. node run node * -command disk show C. node run node * storage show disk -p D. node run node * sysconfig -a Correct Answer: AC QUESTION 17 Click the Exhibit button.
13 You have a FlexPod solution with vsphere ESXi. When you click the icons shown in the exhibit, you do not see any network connectivity details. Which Cisco UCS policy type should you create to enable visibility of these details? A. Link Profile Policy B. Link Protocol Policy C. LAN Connectivity Policy D. Network Control Policy Correct Answer: C Reference b_ucsm_gui_configuration_guide_2_2_chapter_ html QUESTION 18 You are creating the Gold Master Boot LUN for Windows 2012 R2 Hyper-V hosts. In this scenario, which three steps are needed to ensure that all Hyper-V hosts will work as desired? (Choose three.) A. Disassociate the service profile before cloning the LUN. B. Map all Hyper-V hosts to the same Gold Master Boot LUN for consistency.
14 C. Use Sysprep to prepare the operating system for duplication. D. Use a temporary service profile to install and configure the OS. E. Enter in the Windows license key to activate Windows before cloning the LUN. Correct Answer: BDE QUESTION 19 You installed a new NetApp cluster running clustered Data ONTAP. There is a single Storage Virtual Machine (SVM) named esx1 on the cluster. A volume named esx_datastore1 is created in the SVM esx1. The name of the root volume for the esx1 SVM is esx1_rootvol. The default export policy was applied to the volume esx1_rootvol. You verified that the export policy applied to esx_datastore1 contains a single rule that allows all clients to mount the volume as read/write using any version of NFS. A Linux client attempts to NFS mount the volume and receives a Permission Denied error. In this scenario, what caused this error? A. NFS has not been configured on the SVM esx1. B. The volume esx_datastore1 has not been mounted into the namespace of the esx1 SVM. C. UNIX permissions for the volume esx1_rootvol are not set to read/write. D. The default export-policy does not have at least one rule to allow all clients read-only access. Correct Answer: D QUESTION 20 A customer asks you to configure QoS on a Cisco Nexus 7000 Series switch within a FlexPod solution. Which three steps are required to accomplish this task? (Choose three.)
15 A. Attach policies to logical or physical interfaces and VLANs. B. Define traffic classes. C. Associate policies and actions with each traffic class. D. Attach policies to logical or physical interfaces and VSANs. E. Perform a shut/no shut on the affected interfaces. Correct Answer: BCD Reference QUESTION 21 Click the exhibit button. Your vsphere host is booting off an SD and is displaying the error shown in the exhibit. What should you do to correct the problem?
16 A. Enable Unified Extensible Firmware Interface (UEFI). B. Enable SD card mirroring. C. Update the current ESXi scratch location. D. Reinstall ESXi on a larger SD card. Correct Answer: C Reference QUESTION 22 You are deploying a new virtual machine (VM). Your customer requires that the VM cannot reserve space on the VMFS filesystem, and the VM can only consume blocks when data is written to disk from and within the VM/Guest OS. Which virtual disk should you create to meet these requirements? A. Thick Provision Lazy Zeroed B. Thin Provision C. Thick Provision Eager Zeroed D. Independent Nonpersistent Correct Answer: B Reference QUESTION 23 You are asked to create an interface group on a NetApp clustered Data ONTAP system. The system is connected to a Cisco Nexus switch in a vpc configuration with the port-channel mode set to active. Which NetApp interface group made matches this switch configuration? A. multimode B. multimode_lacp
17 C. singlemode D. mode active Correct Answer: C Reference QUESTION 24 You run NetApp Config Advisor against you FAS8060A storage system. The report states that the flow control settings for ports e0a on each node are incorrect. Which set of commands will correct this problem? A. network interface modify- node netapp-01 port e0a flowcontrol admin none network interface modify node netapp-02 port e0a flowcontrol admin none B. network interface modify- node netapp-01 port e0a-flowcontrol-admin full network interface modify- node netapp-02 port e0a-flowcontrol-admin full C. network port modify- node netapp-01 port e0a-flowcontrol-admin none network port modify- node netapp-02 port e0a-flowcontrol-admin none D. network port modify- node netapp-01 port e0a-flowcontrol-admin full network port modify- node netapp-02 port e0a-flowcontrol-admin full Correct Answer: C QUESTION 25 Which management tool is used to configure and monitor centralized policies for multiple Cisco UCS domains? A. UCS Manager B. UCS Director C. UCS Central D. UCS Performance Manager
18 Correct Answer: C Reference QUESTION 26 An administrator has a FlexPod solution for use with a VMware vsphere 6.0 environment. The virtual environment consists of virtual machines running both Windows Server 2012 R2 and Windows Server The administrator determines that the Windows Server 2008 virtual machine VMDKs are misaligned. The problem needs to be solved without incurring downtime on the virtual machines. Which tool enables the administrator to solve the problem without virtual machine downtime? A. VMware vrealize Operations B. NetApp mbralign toolkit C. NetApp Virtual Storage Console D. UCS Central Correct Answer: D QUESTION 27 Which three management tools would you use to configure the NetApp storage component in a FlexPod Datacenter solution? (Choose three.) A. NetApp OnCommand Perfromance Manager B. Cisco UCS Central C. NetApp Virtual Storage Console (VSC) for VMware Sphere D. Cisco UCS Director E. NetApp OnCommand System Manager Correct Answer: BCE
19 QUESTION 28 Click the Exhibit button. An administrator built a FlexPod solution using VMware vsphere 6.0. The ESXi hosts are using NFS for storage connectivity. NFS is configured on the ESXi hosts
20 and the NetApp storage virtual machine (SVM). NFS LIFs are reachable using the ping command form the ESXi hosts. The administrator creates a volume called datastore_nfs_0 on the SVM to use for the NFS datastore. When the administrator attempts to connect to the NFS datastore from the vsphere client, the task fails with the error shown in the exhibit. What should the administrator do to ensure that the NFS datastore will be created? A. Verify that the export policy contains the ESXi hosts. B. Verify that the number of connected NFS mounts is less than 255 on the ESXi hosts. C. Verify that the default security style of the datastore_nfs_0 volume is set to UNIX. D. Execute the vmkping command to verify jumbo frames are working end to end. Correct Answer: A Reference QUESTION 29 Click the Exhibit button.
21 An administrator is configuring a NetApp 8-node AFF8060 system as part of a FlexPod solution and will be cabling the system based on the recommended guidelines shown in the exhibit. Based on this information, which switch would be used for the cluster interconnect connections? A. Nexus 5596 B. NetApp CN1601
22 C. NetApp CN1610 D. Nexus 5548 Correct Answer: C
ATTACHMENT A SCOPE OF WORK IMPLEMENTATION SERVICES. Cisco Server and NetApp Storage Implementation
ATTACHMENT A SCOPE OF WORK IMPLEMENTATION SERVICES I. Executive Summary Superior Court of California, County of Orange (Court) is in the process of conducting a large enterprise hardware refresh. This
More informationVersaStack for Data Center Design & Implementation (VDCDI) 1.0
VersaStack for Data Center Design & Implementation (VDCDI) 1.0 COURSE OVERVIEW: VersaStack for Data Center Design and Implementation (VDCDI) is a four-day training program. The Cisco-IBM VersaStack validated
More informationA. Both Node A and Node B will remain on line and all disk shelves will remain online.
Volume: 75 Questions Question No: 1 On a FAS8040, which port is used for FCoE connections? A. e0m B. e0p C. 0a D. e0h Answer: D Question No: 2 Click the Exhibit button. Referring to the diagram shown in
More informationNS Number: NS0-507 Passing Score: 800 Time Limit: 120 min File Version: NS0-507
NS0-507 Number: NS0-507 Passing Score: 800 Time Limit: 120 min File Version: 1.0 NS0-507 NetApp Certified Implementation Engineer - SAN, Clustered Data ONTAP Exam A QUESTION 1 You are asked to create a
More informationiscsi Configuration for ESXi using VSC Express Guide
ONTAP 9 iscsi Configuration for ESXi using VSC Express Guide May 2018 215-11181_E0 doccomments@netapp.com Updated for ONTAP 9.4 Table of Contents 3 Contents Deciding whether to use this guide... 4 iscsi
More informationCisco HyperFlex Systems
White Paper Cisco HyperFlex Systems Install and Manage Cisco HyperFlex Systems in a Cisco ACI Environment Original Update: January 2017 Updated: March 2018 Note: This document contains material and data
More informationExam Questions NS0-157
Exam Questions NS0-157 NetApp Certified Data Administrator, Clustered https://www.2passeasy.com/dumps/ns0-157/ 1. Clustered Data ONTAP supports which three versions of NFS? (Choose three.) A. NFSv4.1 B.
More informationNetApp. Number: NS0-156 Passing Score: 800 Time Limit: 120 min File Version: 1.0.
NetApp Number: NS0-156 Passing Score: 800 Time Limit: 120 min File Version: 1.0 http://www.gratisexam.com/ Exam A QUESTION 1 Which statement is true about a Data Protection (DP)-type SnapMirror destination
More informationUCS with VMware ESXi End to End Jumbo MTU Configuration Example
UCS with VMware ESXi End to End Jumbo MTU Configuration Example Document ID: 117601 Contributed by Vishal Mehta, Cisco TAC Engineer. Apr 09, 2014 Contents Introduction Prerequisites Requirements Components
More informationns0-157 Passing Score: 700 Time Limit: 120 min File Version: 1.0
ns0-157 Passing Score: 700 Time Limit: 120 min File Version: 1.0 http://www.gratisexam.com/ Exam A QUESTION 1 An IPspace is associated with exactly one? A. broadcast domain B. SVM C. port D. root volume
More informationNS0-506 Q&As NetApp Certified Implementation Engineer - SAN, Clustered Data ONTAP
CertBus.com NS0-506 Q&As NetApp Certified Implementation Engineer - SAN, Clustered Data ONTAP Pass NetApp NS0-506 Exam with 100% Guarantee Free Download Real Questions & Answers PDF and VCE file from:
More informationCISCO EXAM QUESTIONS & ANSWERS
CISCO 642-999 EXAM QUESTIONS & ANSWERS Number: 642-999 Passing Score: 800 Time Limit: 90 min File Version: 32.5 http://www.gratisexam.com/ Sections 1. Questions 2. Drag & Drop 3. Hot Spot CISCO 642-999
More informationQuestions & Answers
642-999 Questions & Answers Number: 642-999 Passing Score: 800 Time Limit: 90 min File Version: 36.6 http://www.gratisexam.com/ 642-999 Questions & Answers Exam Name: Implementing Cisco Data Center Unified
More informationTest Range NetApp Build Document
Test Range NetApp Build Document Purpose: This document describes the hardware, software, cabling and configuration for the NDB Test Range NetApp as built during NetApp SE onsite support visit. In addition,
More informationQuestion: 1 You have a Cisco UCS cluster and you must recover a lost admin password. In which order must you power cycle the fabric interconnects?
Volume: 327 Questions Question: 1 You have a Cisco UCS cluster and you must recover a lost admin password. In which order must you power cycle the fabric interconnects? A. primary first, and then secondary
More information2V0-602.exam. Number: 2V0-602 Passing Score: 800 Time Limit: 120 min File Version: Vmware 2V0-602
2V0-602.exam Number: 2V0-602 Passing Score: 800 Time Limit: 120 min File Version: 1.0 Vmware 2V0-602 VMware vsphere 6.5 Foundations Version 1.0 Exam A QUESTION 1 A vsphere Administrator recently introduced
More informationEXAM - NS NetApp Certified Implementation Engineer - SAN, Clustered Data ONTAP. Buy Full Product.
Network Appliance EXAM - NS0-506 NetApp Certified Implementation Engineer - SAN, Clustered Data ONTAP Buy Full Product http://www.examskey.com/ns0-506.html Examskey Network Appliance NS0-506 exam demo
More informationFlexPod Express with VMware vsphere 5.1u1 Implementation Guide
Technical Report FlexPod Express with VMware vsphere 5.1u1 Implementation Guide Karthick Radhakrishnan, Arvind Ramakrishnan, Lindsey Street, NetApp Jeffrey Fultz, Cisco March 2014 TR-4261 TABLE OF CONTENTS
More informationITBraindumps. Latest IT Braindumps study guide
ITBraindumps http://www.itbraindumps.com Latest IT Braindumps study guide Exam : 300-460 Title : Implementing and Troubleshooting the Cisco Cloud Infrastructure Vendor : Cisco Version : DEMO Get Latest
More informationCISCO EXAM QUESTIONS & ANSWERS
CISCO 642-999 EXAM QUESTIONS & ANSWERS Number: 642-999 Passing Score: 800 Time Limit: 90 min File Version: 32.5 http://www.gratisexam.com/ Sections 1. Questions 2. Drag & Drop 3. Hot Spot CISCO 642-999
More informationVmware VCP-511. VMware Certified Professional on vsphere 5 (Private Beta) Download Full Version :
Vmware VCP-511 VMware Certified Professional on vsphere 5 (Private Beta) Download Full Version : http://killexams.com/pass4sure/exam-detail/vcp-511 in RAM. A virtual machine running completely in RAM performs
More informationVirtual Storage Console, VASA Provider, and Storage Replication Adapter for VMware vsphere
Virtual Storage Console, VASA Provider, and Storage Replication Adapter for VMware vsphere Workflow Guide for 7.2 release July 2018 215-13170_B0 doccomments@netapp.com Table of Contents 3 Contents Deciding
More informationConfiguring Cisco UCS Server Pools and Policies
This chapter contains the following sections: Global Equipment Policies, page 1 UUID Pools, page 3 Server Pools, page 5 Management IP Pool, page 7 Boot Policy, page 8 Local Disk Configuration Policy, page
More informationCisco Actualtests Questions & Answers
Cisco Actualtests 642-999 Questions & Answers Number: 642-999 Passing Score: 800 Time Limit: 90 min File Version: 22.8 http://www.gratisexam.com/ Sections 1. Questions 2. Drag & Drop 3. Hot Spot Cisco
More informationDirect Attached Storage
, page 1 Fibre Channel Switching Mode, page 1 Configuring Fibre Channel Switching Mode, page 2 Creating a Storage VSAN, page 3 Creating a VSAN for Fibre Channel Zoning, page 4 Configuring a Fibre Channel
More informationExam Questions NS0-180
Exam Questions NS0-180 NetApp Certified Storage Installation Engineer, Clustered Data ONTAP https://www.2passeasy.com/dumps/ns0-180/ 1. Which three types of interface groups are supported on NetApp storage
More informationCisco ACI with Cisco AVS
This chapter includes the following sections: Cisco AVS Overview, page 1 Cisco AVS Installation, page 6 Key Post-Installation Configuration Tasks for the Cisco AVS, page 43 Distributed Firewall, page 62
More informationConfiguring Cisco UCS Server Pools and Policies
This chapter contains the following sections: Global Equipment Policies, page 1 UUID Pools, page 4 Server Pools, page 5 Management IP Pool, page 7 Boot Policy, page 8 Local Disk Configuration Policy, page
More informationConnect array to Cisco UCS and VMware vsphere
Summary This article provides a step-by-step guidance to setup a Cisco UCS with a Nimble Storage iscsi array and VMware vsphere. Note: This document does not cover any boot from SAN configuration. Setup
More informationNS0-191 netapp. Number: NS0-191 Passing Score: 800 Time Limit: 120 min.
NS0-191 netapp Number: NS0-191 Passing Score: 800 Time Limit: 120 min Exam A QUESTION 1 An administrator notices that the clustered Data ONTAP 8.2.3 controllers are less responsive than normal. You use
More informationONTAP 9 Cluster Administration. Course outline. Authorised Vendor e-learning. Guaranteed To Run. DR Digital Learning. Module 1: ONTAP Overview
ONTAP 9 Cluster Administration Course Code: Duration: 3 Days Product Page: https://digitalrevolver.com/product/ontap-9-cluster-administration-2/ This 3-day, instructor led course uses lecture and hands-on
More informationOracle Database Consolidation on FlashStack
White Paper Oracle Database Consolidation on FlashStack with VMware 2017 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public. Page 1 of 18 Contents Executive Summary Introduction
More informationVMware View on NetApp Deployment Guide
Technical Report VMware View on NetApp Deployment Guide Jack McLeod, Chris Gebhardt, Abhinav Joshi, NetApp February 2010 TR-3770 A SCALABLE SOLUTION ARCHITECTURE USING NFS ON A CISCO NEXUS NETWORK INFRASTRUCTURE
More informationVMware vsphere Administration Training. Course Content
VMware vsphere Administration Training Course Content Course Duration : 20 Days Class Duration : 3 hours per day (Including LAB Practical) Fast Track Course Duration : 10 Days Class Duration : 8 hours
More informationSAN Configuration Guide
ONTAP 9 SAN Configuration Guide November 2017 215-11168_G0 doccomments@netapp.com Updated for ONTAP 9.3 Table of Contents 3 Contents Considerations for iscsi configurations... 5 Ways to configure iscsi
More informationVMware vsphere with ESX 4.1 and vcenter 4.1
QWERTYUIOP{ Overview VMware vsphere with ESX 4.1 and vcenter 4.1 This powerful 5-day class is an intense introduction to virtualization using VMware s vsphere 4.1 including VMware ESX 4.1 and vcenter.
More informationCisco UCS Director Tech Module Cisco UCS Manager (UCSM)
Cisco UCS Director Tech Module Cisco UCS Manager (UCSM) Version: 1.0 September 2016 1 Agenda Overview & Architecture Hardware & Software Compatibility Licensing Orchestration Capabilities Reports Example
More informationVMware vsphere with ONTAP
Technical Report VMware vsphere with ONTAP Karl L. Konnerth, NetApp February 2018 TR-4597 Abstract NetApp ONTAP is a powerful and flexible data management solution for VMware vsphere environments and continues
More informationCisco CCIE Data Center Written (Beta) Download Full Version :
Cisco 351-080 CCIE Data Center Written (Beta) Download Full Version : https://killexams.com/pass4sure/exam-detail/351-080 Answer: A QUESTION: 105 What is the function of the WWPN pool? A. to assign WWPNs
More informationFlexPod Datacenter with NetApp MetroCluster
NetApp Verified Architecture FlexPod Datacenter with NetApp MetroCluster NVA Design Guide Aaron Kirk, David Klem, Arvind Ramakrishnan, NetApp September 2016 NVA-0030-DESIGN Version 1.0 Reviewed by TABLE
More informationActual4Test. Actual4test - actual test exam dumps-pass for IT exams
Actual4Test http://www.actual4test.com Actual4test - actual test exam dumps-pass for IT exams Exam : NS0-158 Title : NetApp Certified Data Administrator, ONTAP Vendor : Network Appliance Version : DEMO
More informationFlexPod Datacenter FedRAMP Readiness with VMware vsphere 6.0, HyTrust CloudControl and DataControl
NetApp Verified Architecture FlexPod Datacenter FedRAMP Readiness with VMware vsphere 6.0, HyTrust CloudControl and DataControl NVA Design and Deployment Arvind Ramakrishnan, Karthick Radhakrishnan, NetApp
More informationAvailability for the Modern Data Center on FlexPod Introduction NetApp, Inc. All rights reserved. NetApp Proprietary Limited Use Only
Availability for the Modern Data Center on FlexPod Introduction 2014 NetApp, Inc. All rights reserved. NetApp Proprietary Limited Use Only Abstract Veeam Availability Suite v8 leverages NetApp storage
More informationVMware vsphere with ESX 6 and vcenter 6
VMware vsphere with ESX 6 and vcenter 6 Course VM-06 5 Days Instructor-led, Hands-on Course Description This class is a 5-day intense introduction to virtualization using VMware s immensely popular vsphere
More information2V0-622 vmware. Number: 2V0-622 Passing Score: 800 Time Limit: 120 min.
2V0-622 vmware Number: 2V0-622 Passing Score: 800 Time Limit: 120 min Exam A QUESTION 1 What two debugging levels can a virtual machine be configured to? (Choose two.) A. Verbose B. Debugging C. Statistics
More informationReal4Test. Real IT Certification Exam Study materials/braindumps
Real4Test http://www.real4test.com Real IT Certification Exam Study materials/braindumps Exam : 300-175 Title : Implementing Cisco Data Center Unified Computing Vendor : Cisco Version : DEMO Get Latest
More informationQuestion No: 2 What three shares are available when configuring a Resource Pool? (Choose three.)
Volume: 70 Questions Question No: 1 A VMware vsphere 6.x Administrator sees the following output In esxtop: What does the %ROY column represent? A. CPU Cycle Walt Percentage B. CPU Utilization C. CPU Ready
More informationFlexPod Datacenter with VMware vsphere 6.5, NetApp AFF A-Series and Fibre Channel
FlexPod Datacenter with VMware vsphere 6.5, NetApp AFF A-Series and Fibre Channel Deployment Guide for FlexPod Datacenter with Fibre Channel SAN and VMware vsphere 6.5 and ONTAP 9.1 Last Updated: April
More informationVblock Architecture. Andrew Smallridge DC Technology Solutions Architect
Vblock Architecture Andrew Smallridge DC Technology Solutions Architect asmallri@cisco.com Vblock Design Governance It s an architecture! Requirements: Pretested Fully Integrated Ready to Go Ready to Grow
More informationService Profiles and Templates
Service Profile Templates, page 1 Service Profiles, page 3 Service Profile Templates Service profile templates enable you to quickly create several service profiles with the same basic parameters, such
More informationService Profiles. Service Profiles in UCS Manager
in UCS Manager, on page 1 that Override Server Identity, on page 2 that Inherit Server Identity, on page 2 Guidelines and Recommendations for, on page 3 Methods of Creating, on page 3 Inband, on page 7
More informationNS0-180 netapp
NS0-180 netapp Number: NS0-180 Passing Score: 800 Time Limit: 120 min Exam A QUESTION 1 You want to create a data volume on aggr0 and you receive a message with the following warning: ''Warning: You are
More informationDumpExam. The best exam dump, valid dumps PDF, accurate exam materials provider
DumpExam http://www.dumpexam.com The best exam dump, valid dumps PDF, accurate exam materials provider Exam : 2V0-602 Title : VMware vsphere 6.5 Foundations Vendor : VMware Version : DEMO Get Latest &
More informationNetworkAppliance NS NetApp Certified Data Administrator, ONTAP.
NetworkAppliance NS0-158 NetApp Certified Data Administrator, ONTAP http://killexams.com/pass4sure/exam-detail/ns0-158 Question: 67 What is the minimum number of disks required to create a data aggregate
More informationPassTest. Bessere Qualität, bessere Dienstleistungen!
PassTest Bessere Qualität, bessere Dienstleistungen! Q&A Exam : VCP-510 Title : VMware Certified Professional on VSphere 5 Version : Demo 1 / 7 1.Which VMware solution uses the security of a vsphere implementation
More information2V0-622D.exam. VMWARE 2V0-622D. VMware Certified Professional 6.5 Data Center Virtualization Delta Exam. Version 1.
2V0-622D.exam Number: 2V0-622D Passing Score: 800 Time Limit: 120 min File Version: 1.0 VMWARE 2V0-622D VMware Certified Professional 6.5 Data Center Virtualization Delta Exam Version 1.0 Exam A QUESTION
More informationVMware Exam VCP-511 VMware Certified Professional on vsphere 5 Version: 11.3 [ Total Questions: 288 ]
s@lm@n VMware Exam VCP-511 VMware Certified Professional on vsphere 5 Version: 11.3 [ Total Questions: 288 ] VMware VCP-511 : Practice Test Question No : 1 Click the Exhibit button. An administrator has
More informationCluster Management Workflows for OnCommand System Manager
ONTAP 9 Cluster Management Workflows for OnCommand System Manager August 2018 215-12669_C0 doccomments@netapp.com Table of Contents 3 Contents OnCommand System Manager workflows... 5 Setting up a cluster
More informationConfiguring Service Profiles
Configuring Service Profiles This chapter includes the following sections: Service Profiles that Override Server Identity, page 1 Service Profiles that Inherit Server Identity, page 2 Service Profile Templates,
More information1V Number: 1V0-621 Passing Score: 800 Time Limit: 120 min. 1V0-621
1V0-621 Number: 1V0-621 Passing Score: 800 Time Limit: 120 min 1V0-621 VMware Certified Associate 6 - Data Center Virtualization Fundamentals Exam Exam A QUESTION 1 Which tab in the vsphere Web Client
More informationNFS Client Configuration with VAAI for ESX Express Guide
ONTAP 9 NFS Client Configuration with VAAI for ESX Express Guide February 2018 215-11184_F0 doccomments@netapp.com Updated for ONTAP 9.3 Table of Contents 3 Contents Deciding whether to use this guide...
More informationConfigure HyperFlex Hardware Acceleration Cards
Configure HyperFlex Hardware Acceleration Cards This chapter describes how to configure Cisco HyperFlex Hardware Acceleration Cards. Overview of HyperFlex Hardware Acceleration Cards, on page 1 Install
More information"Charting the Course... Troubleshooting Cisco Data Center Infrastructure v6.0 (DCIT) Course Summary
Description Troubleshooting Cisco Data Center Infrastructure v6.0 (DCIT) Course Summary v6.0 is a five-day instructor-led course that is designed to help students prepare for the Cisco CCNP Data Center
More informationPreparing Virtual Machines for Cisco APIC-EM
Preparing a VMware System for Cisco APIC-EM Deployment, page 1 Virtual Machine Configuration Recommendations, page 1 Configuring Resource Pools Using vsphere Web Client, page 4 Configuring a Virtual Machine
More informationPreparing Virtual Machines for Cisco APIC-EM
Preparing a VMware System for Cisco APIC-EM Deployment, on page 1 Virtual Machine Configuration Recommendations, on page 1 Configuring Resource Pools Using vsphere Web Client, on page 4 Configuring a Virtual
More informationExam Questions
Exam Questions 300-460 CLDINF Implementing and Troubleshooting the Cisco Cloud Infrastructure https://www.2passeasy.com/dumps/300-460/ 1. Which configuration provides the highest performance level to Virtual
More informationSAN Implementation (SANIW)
SAN Implementation (SANIW) COURSE OVERVIEW: In this workshop course, you learn how to connect Windows _, vsphere, and Linux _ hosts via Fibre Channel (FC) and iscsi protocols to NetApp _ SANs. WHO WILL
More informationFlexPod Express with VMware vsphere 6.7 and NetApp AFF A220
NetApp Verified Architecture FlexPod Express with VMware vsphere 6.7 and NetApp AFF A220 NVA Deployment Savita Kumari, NetApp October 2018 NVA-1123-DEPLOY Version 1.0 Reviewed by TABLE OF CONTENTS 1 Program
More informationiscsi Configuration for ESX Express Guide
ONTAP 9 iscsi Configuration for ESX Express Guide December 2017 215-11181_D0 doccomments@netapp.com Updated for ONTAP 9.3 Table of Contents 3 Contents Deciding whether to use this guide... 4 iscsi configuration
More informationUCS deployment guide for Nimble Storage
Summary This article is intended as a how to guide to allow for successful deployment of Nimble Storage iscsi connectivity to Cisco UCS. Nimble Storage / Cisco UCS connectivity checklist: 1) Determine
More informationVmware VCP-310. VMware Certified Professional on VI3.
Vmware VCP-310 VMware Certified Professional on VI3 http://killexams.com/exam-detail/vcp-310 D. Only one VLAN can be specified in a port group. Answer: B, D Question: 423 What is a characteristic of a
More informationImplementing Cisco Data Center Unified Computing (DCUCI)
Implementing Cisco Data Center Unified Computing (DCUCI) Number: 642-999 Passing Score: 800 Time Limit: 90 min File Version: 3.0 http://www.gratisexam.com/ Exam Topics Implement C-Series stand alone Implementing
More informationFlexPod Datacenter with Microsoft Applications and NetApp AFF A-Series
NetApp Verified Architecture FlexPod Datacenter with Microsoft Applications and NetApp AFF A-Series NVA Design Glenn Sizemore, Bhavin Shah, NetApp September 2017 NVA-1116-DESIGN Version 1.0 Reviewed by
More informationFCoE Configuration Between VIC Adapter on UCS Rack Server and Nexus 5500 Switch
FCoE Configuration Between VIC Adapter on UCS Rack Server and Nexus 5500 Switch Document ID: 117280 Contributed by Padmanabhan, Cisco TAC Engineer. Mar 25, 2014 Contents Introduction Prerequisites Requirements
More informationITdumpsFree. Get free valid exam dumps and pass your exam test with confidence
ITdumpsFree http://www.itdumpsfree.com Get free valid exam dumps and pass your exam test with confidence Exam : NS0-180 Title : NetApp Certified Storage Installation Engineer, Clustered Data ONTAP Vendor
More informationVMware Virtual SAN. Technical Walkthrough. Massimiliano Moschini Brand Specialist VCI - vexpert VMware Inc. All rights reserved.
VMware Virtual SAN Technical Walkthrough Massimiliano Moschini Brand Specialist VCI - vexpert 2014 VMware Inc. All rights reserved. VMware Storage Innovations VI 3.x VMFS Snapshots Storage vmotion NAS
More informationQ&As. Troubleshooting Cisco Data Center Infrastructure. Pass Cisco Exam with 100% Guarantee
300-180Q&As Troubleshooting Cisco Data Center Infrastructure Pass Cisco 300-180 Exam with 100% Guarantee Free Download Real Questions & Answers PDF and VCE file from: 100% Passing Guarantee 100% Money
More informationNetapp Exam NS0-157 NetApp Certified Data Administrator, Clustered Data ONTAP Version: 11.0 [ Total Questions: 302 ]
s@lm@n Netapp Exam NS0-157 NetApp Certified Data Administrator, Clustered Data ONTAP Version: 11.0 [ Total Questions: 302 ] https://certkill.com Topic break down Topic No. of Questions Topic 1: Volume
More informationvsphere Networking Update 1 ESXi 5.1 vcenter Server 5.1 vsphere 5.1 EN
Update 1 ESXi 5.1 vcenter Server 5.1 vsphere 5.1 This document supports the version of each product listed and supports all subsequent versions until the document is replaced by a new edition. To check
More informationActual4Test. Actual4test - actual test exam dumps-pass for IT exams
Actual4Test http://www.actual4test.com Actual4test - actual test exam dumps-pass for IT exams Exam : 642-999 Title : Implementing Cisco Data Center Unified Computing Vendor : Cisco Version : DEMO Get Latest
More informationFlexPod Express with Microsoft Windows 2016 Hyper-V and FAS2600
NetApp Verified Architecture FlexPod Express with Microsoft Windows 2016 Hyper-V and FAS2600 NVA Deployment Melissa Palmer, Lindsey Street, NetApp May 2017 NVA-1114-DEPLOY Version 1.0 Reviewed by Cisco
More informationPassit4Sure.2V
Passit4Sure.2V0-620.121 Number: 2V0-620 Passing Score: 800 Time Limit: 120 min File Version: 4.5 http://www.gratisexam.com/ 2V0-620 vsphere 6 Foundations Beta Exam I just passed today with 89%. My sole
More informationConfiguring and Managing Virtual Storage
Configuring and Managing Virtual Storage Module 6 You Are Here Course Introduction Introduction to Virtualization Creating Virtual Machines VMware vcenter Server Configuring and Managing Virtual Networks
More informationActualtests.VCI questions
Actualtests.VCI510.322 questions Number: VCI510 Passing Score: 800 Time Limit: 120 min File Version: 5.8 http://www.gratisexam.com/ VCI510 VMware Certified Professional 5 - Data Center Virtualization for
More informationImplementing Cisco Data Center Unified Computing (DCUCI)
Implementing Cisco Data Center Unified Computing (DCUCI) Number: 642-999 Passing Score: 800 Time Limit: 90 min File Version: 3.0 http://www.gratisexam.com/ Exam Topics Implement C-Series stand alone Implementing
More informationNimble Storage SmartStack Getting Started Guide Cisco UCS and VMware ESXi5
Technical Marketing Solutions Guide Nimble Storage SmartStack Getting Started Guide Cisco UCS and VMware ESXi5 Document Revision Date Revision Description (author) 5/16/2014 1. 0 Draft release (mmclaughlin)
More informationFlexPod Express with VMware vsphere 6.5 and FAS2600
NetApp Verified Architecture FlexPod Express with VMware vsphere 6.5 and FAS2600 NVA Deployment Melissa Palmer, Lindsey Street, NetApp April 2017 NVA-1112-DEPLOY Version 1.0 Reviewed by Cisco Systems,
More informationData Protection Guide
SnapCenter Software 4.0 Data Protection Guide For VMs and Datastores using the SnapCenter Plug-in for VMware vsphere March 2018 215-12931_C0 doccomments@netapp.com Table of Contents 3 Contents Deciding
More informationNetApp AltaVault and Symantec NetBackup Solution with FlexPod Datacenter and ACI
NetApp Verified Architecture NetApp AltaVault and Symantec NetBackup Solution with FlexPod Datacenter and ACI Nabil Fares and David Arnette, NetApp November 2015 NVA-0019-DEPLOY Version 1.0 TABLE OF CONTENTS
More informationCisco Questions & Answers
Cisco 642-999 Questions & Answers Number: 642-999 Passing Score: 800 Time Limit: 90 min File Version: 24.4 http://www.gratisexam.com/ 642-999 Questions & Answers Exam Name: Implementing Cisco Data Center
More informationDell EMC. VxBlock and Vblock Systems 350 Administration Guide
Dell EMC VxBlock and Vblock Systems 350 Administration Guide Document revision 1.10 June 2018 Revision history Date Documen t revision Description of changes June 2018 1.10 Changed the following sections
More informationDownpour II: Converged Infrastructure with VMware vsphere 5.5 Solution
1) Technical Report Downpour II: Converged Infrastructure with VMware vsphere 5.5 Solution NetApp and HP Blade Servers with Cisco Nexus Switches Chris Rodriguez, David Arnette, Gary Riker, NetApp March
More informationData Protection Guide
SnapCenter Software 4.1 Data Protection Guide For VMs and Datastores using the SnapCenter Plug-in for VMware vsphere September 2018 215-13399_B0 doccomments@netapp.com Table of Contents 3 Contents Deciding
More informationFlexPod Express with VMware vsphere 6.7U1 and NetApp AFF A220 with Direct- Attached IP-Based Storage
NetApp Verified Architecture FlexPod Express with VMware vsphere 6.7U1 and NetApp AFF A220 with Direct- Attached IP-Based Storage NVA Deployment Sree Lakshmi Lanka, NetApp April 2019 NVA-1131-DEPLOY Version
More informationFibre Channel Zoning
Information About, page 1 Support for in Cisco UCS Manager, page 2 Guidelines and recommendations for Cisco UCS Manager-Based, page 4 Configuring, page 4 Creating a VSAN for, page 6 Creating a New Fibre
More informationUCS Direct Attached Storage and FC Zoning Configuration Example
UCS Direct Attached Storage and FC Zoning Configuration Example Document ID: 116082 May 23, 2013 Contents Introduction Prerequisites Requirements Components Used Conventions Background Information UCS
More informationVMware Exam VCP550D VMware Certified Professional 5 - Data Center Virtualization Delta Exam Version: 6.1 [ Total Questions: 270 ]
s@lm@n VMware Exam VCP550D VMware Certified Professional 5 - Data Center Virtualization Delta Exam Version: 6.1 [ Total Questions: 270 ] Question No : 1 An administrator is planning a vsphere infrastructure
More informationvsphere 6.0 with HP ProLiant Gen9 Servers, OneView, 3PAR, Cisco Nexus 5600 and Brocade 6510 Deployment Guide
Technical white paper vsphere 6.0 with HP ProLiant Gen9 Servers, OneView, 3PAR, Cisco Nexus 5600 and Brocade 6510 Deployment Guide Updated: 4/30/2015 Hongjun Ma, HP DCA Table of contents Introduction...
More informationTraffic Monitoring. Traffic Monitoring
, page 1 Creating a Session, page 6 Editing an Existing Session, page 7 Activating or Deactivating a Session, page 7 Deleting a Session, page 8 Traffic monitoring copies traffic, from one or more source
More informationClustered Data ONTAP 8.3
Clustered Data ONTAP 8.3 FC Configuration for ESX Express Guide NetApp, Inc. 495 East Java Drive Sunnyvale, CA 94089 U.S. Telephone: +1 (408) 822-6000 Fax: +1 (408) 822-4501 Support telephone: +1 (888)
More information