MINI MCR-SL-MUX-V8-FLK 16

Size: px
Start display at page:

Download "MINI MCR-SL-MUX-V8-FLK 16"

Transcription

1 Multiplexer Data sheet 445_en_4 PHOENIX CONTACT Description The MINI Analog multiplexer can be used to generate one analog output from up to eight input signals. During cyclical execution, 8, 6, 4 or 2 parallel analog signals can be transmitted in series, i.e., one after the other, via a cable using the MINI Analog multiplexer. A or 2-second cycle can be selected via DIP switches. The desired number of channels is also selected via DIP switches. Features Minimal space requirements Fast installation Modular design Can be set via DIP switches Reduction in analog inputs at controllers Wear-free optocoupler outputs Attention: Correct usage in potentially explosive areas The module is a category 3 item of electrical equipment. It is absolutely vital to follow the instructions provided here during installation and observe the information in the "Safety regulations and installation notes". Make sure you always use the latest documentation. It can be downloaded from the product at This data sheet is valid for all products listed on the following page:

2 2 Table of contents Description... 2 Table of contents Ordering data Technical data Safety regulations and installation notes Installation notes Installation in the Ex area (zone 2) Dimensional drawing Installation Connection notes Structure Modular design FLK 6 connector pin assignment Power supply Bit pattern for channel display Configuration Installing the MINI Analog multiplexer on a MINI Analog module... 9 Installing a system cable with FLK 6 connector Releasing the engagement catch Opening the FLK 6 connector connection Connecting a system cable with FLK 6 connector connection....4 Disconnecting a system cable with FLK 6 connector connection... Connection/application example.... Monitoring motor temperatures....2 Example of an alternative solution _en_4 PHOENIX CONTACT 2

3 3 Ordering data Description Type Order No. Pcs. / Pkt. MINI analog multiplexer, generates one analog output from 8 analog input signals, for MINI analog module with screw connection. MINI MCR-SL-MUX-V8-FLK Accessories Type Order No. Pcs. / Pkt. Feed-through terminal block for transmission of signals that are already electrically isolated Assembled round cable with a 6-pos. molded socket strip (9 output) and an open end. On the open end, the wires are labeled with to 6 and have ferrules, cable length:.5 m Assembled round cable with a 6-pos. molded socket strip (9 output) and an open end. On the open end, the wires are labeled with to 6 and have ferrules, cable length: m Assembled round cable with a 6-pos. molded socket strip (9 output) and an open end. On the open end, the wires are labeled with to 6 and have ferrules, cable length:.5 m Assembled round cable with a 6-pos. molded socket strip (9 output) and an open end. On the open end, the wires are labeled with to 6 and have ferrules, cable length: 2 m Assembled round cable with a 6-pos. molded socket strip (9 output) and an open end. On the open end, the wires are labeled with to 6 and have ferrules, cable length: 3 m Assembled round cable with a 6-pos. molded socket strip (9 output) and an open end. On the open end, the wires are labeled with to 6 and have ferrules, cable length: 4 m Assembled round cable with a 6-pos. molded socket strip (9 output) and an open end. On the open end, the wires are labeled with to 6 and have ferrules, cable length: 6 m length:.5 m length:. m length:.5 m length: 2. m length: 2.5 m length: 3. m length: 4. m length: 6. m 2842 VIP-CAB-FLK6/FR/OE/,4/,5M 293 VIP-CAB-FLK6/FR/OE/,4/,M 293 VIP-CAB-FLK6/FR/OE/,4/,5M 2932 VIP-CAB-FLK6/FR/OE/,4/2,M 2933 VIP-CAB-FLK6/FR/OE/,4/3,M 2934 VIP-CAB-FLK6/FR/OE/,4/4,M 2935 VIP-CAB-FLK6/FR/OE/,4/6,M 2936 CABLE-FLK6/OE/,4/,5M CABLE-FLK6/OE/,4/,M 2383 CABLE-FLK6/OE/,4/,5M CABLE-FLK6/OE/,4/ 2,M CABLE-FLK6/OE/,4/ 2,5M CABLE-FLK6/OE/,4/ 3,M CABLE-FLK6/OE/,4/ 4,M CABLE-FLK6/OE/,4/ 6,M _en_4 PHOENIX CONTACT 3

4 Accessories Type Order No. Pcs. / Pkt. length: 8. m length:. m the open end, the wires are labeled with to 6 and have ferrules, variable cable length CABLE-FLK6/OE/,4/ 8,M CABLE-FLK6/OE/,4/,M 2382 CABLE-FLK6/OE/,4/ _en_4 PHOENIX CONTACT 4

5 4 Technical data Input Description of the input Configurable/programmable Current input signal Max. current input signal Switching cycles 2, 4, 6, or 8-channel(can be switched over) Via DIP switches 4 ma... 2 ma < 3 ma 2 or sec. (can be selected) Output Current output signal 4 ma... 2 ma Max. current output signal < 3 ma Load/output load current output ((U supply - 7 V) / I max ) Status display, 2, 3-bit digital output (can be selected) Output description 3 x PNP optocouplers Maximum switching voltage 3 V DC Supply Supply voltage Supply voltage range Max. current consumption Power consumption General data Maximum transmission error Maximum temperature coefficient Dimensions W / H / D Type of housing Loop-powered 7 V DC... 3 V DC (Loop-powered) < 3.5 ma (without signal current) < 24 mw (without signal current).3 % (.%, typical) <. %/K 5.4 mm / 45.5 mm / 46.2 mm PBT green Connection data FLK connector Flat-ribbon cable plug connector in acc. with IEC Insertion/withdrawal cycles FLK connector min. 2 Adapter MINI Analog multiplexer Flat-ribbon cable connector, in acc. with IEC (engagement catches based on IEC 663-3) Number of positions MINI Analog multiplexer 6 Insertion/withdrawal cycles MINI Analog multiplexer Ambient conditions Ambient temperature (operation) -2 C C Ambient temperature (storage/transport) -4 C... 8 C Conformance with EMC Directive 24/8/EC Noise immunity according to EN Noise emission according to EN Conformance / approvals Conformance ATEX CE-compliant II 3 G Ex na IIC T4 Gc X 445_en_4 PHOENIX CONTACT 5

6 5 Safety regulations and installation notes 5. Installation notes The category 3 device is suitable for installation in the zone 2 potentially explosive area. It fulfills the requirements of EN 679-:29 and EN 679-5:2. Installation, operation, and maintenance may only be carried out by qualified electricians. Follow the installation instructions described. When installing and operating the device, the applicable regulations and safety directives (including national safety directives), as well as general technical regulations, must be observed. The technical data is provided in this package slip and on the certificates (conformity assessment, additional approvals where applicable). It is not permissible to open or modify the device. Do not repair the device yourself but replace it with an equivalent device. Repairs may only be carried out by the manufacturer. The manufacturer is not liable for damage resulting from violation. The IP2 degree of protection (IEC 6529/EN 6529) of the device is intended for use in a clean and dry environment. Do not subject the device to any load that exceeds the described limits. The device is not designed for use in atmospheres with a danger of dust explosions. 5.2 Installation in the Ex area (zone 2) Observe the specified conditions for use in potentially explosive areas. The device must be installed in a housing (control or distributor box) which meets the requirements of EN and provides at least IP54 (EN 6529) degree of protection. When installing and connecting the supply and signal circuits, observe the requirements of EN Only devices which are designed for operation in Ex zone 2 and are suitable for the conditions at the installation location may be connected to the circuits in the Ex zone. In potentially explosive areas, only connect and disconnect cables when the power is disconnected. The device must be stopped and immediately removed from the Ex area if it is damaged or was subject to an impermissible load or stored incorrectly or if it malfunctions. You can download the latest documents for these devices from 445_en_4 PHOENIX CONTACT 6

7 6 Dimensional drawing 7.2 Structure 96,66 (,59) Figure 7 Installation 67,74 Dimensions of the module When using feed-through terminal blocks (Order No. 2842) for transmitting a signal, electrical isolation between the sensor and the output side of the multiplexers must be made possible otherwise no analog output signal is measurable at the multiplexer. 7 Figure 2 Rear structure. FLK 6 connector connection 2. Ejector lever 3. Engagement catch 4. Screw cover 5. Screw cover 6. Screw contacts 7. Spring contacts 6 The following possibilities exist to ensure electrical isolation when using feed-through terminal blocks:. Use of an electrically isolated sensor 2. Use of a special electrically isolated supply at the sensor 3. Use of electrically isolated controller cards 4. Use of a MINI MCR-SL-RPS-I-I (-SP) ( or ) repeater power supply at the analog output of the multiplexer This must not be observed when using feed-through terminal blocks for filling blocks of 8. 4 on off S 7. Connection notes 8 The device contains components that can be damaged or destroyed by electrostatic discharge. When handling the device, observe the necessary safety precautions against electrostatic discharge (ESD) according to EN and EN Figure 3 8. DIP switch Front structure 445_en_4 PHOENIX CONTACT 7

8 7.3 Modular design The MINI Analog multiplexer is designed for a maximum of eight channels. If you require fewer than eight channels, you must fill the unused channels with a corresponding number of feed-through terminal blocks (Order No. 2842). 8x IN MINI MCR-SL-MUX.. OUT 6x IN MINI MCR-SL-MUX.. OUT Active channel Bit Bit 2 Bit 3 2 Active 3 Active 4 Active Active 5 Active 6 Active Active 7 Active Active 8 Active Active Active 8 Configuration 4x IN OUT Figure 4 Modular design MINI MCR-SL-MUX.. 2x IN MINI MCR-SL-MUX.. OUT Use DIP switch S to set the required configuration of the MINI Analog multiplexer. 2 3 Number of channels 2 x 4 x x x 6 x x FLK 6 connector pin assignment x = ON AO BIT 2 BIT2 3 4 BIT PWR I In Out Figure D+ D- D2+ D2-D3+ D3- FLK 6 connector pin assignment 7.5 Power supply The MINI Analog multiplexer is supplied via the current loop. Apply the "+" voltage at PIN "PWR IN" of the FLK connector/ cable. 7.6 Bit pattern for channel display The digital outputs indicate the active channel using a bit pattern. 445_en_4 PHOENIX CONTACT 8

9 9 Installing the MINI Analog multiplexer on a MINI Analog module Installing a system cable with FLK 6 connector. Insert the MINI Analog multiplexer in the MINI Analog module. 2. Tighten the two screws on the MINI Analog module using a suitable screwdriver. The MINI Analog multiplexer is now secured in place. 3. The screws at the other spring contacts must not and cannot be tightened due to the screw covers of the MINI Analog multiplexer.. Releasing the engagement catch Open the engagement catch using a suitable tool (e.g., screwdriver). Figure 7 Releasing the engagement catch Figure 6 Installing the MINI Analog multiplexer.2 Opening the FLK 6 connector connection Open the ejector lever. Figure 8 Opening the ejector lever 445_en_4 PHOENIX CONTACT 9

10 ... MINI MCR-SL-MUX-V8-FLK 6.3 Connecting a system cable with FLK 6 connector connection To connect a system cable with FLK 6 connector connection, proceed as follows:. Insert the system cable with FLK 6 connector connection in the base strip, observing the plug-in direction. 2. Close the ejector lever manually. 3. Secure the FLK 6 connector connection so that it cannot move by closing the engagement catch..4 Disconnecting a system cable with FLK 6 connector connection. Open the engagement catch using a suitable tool (e.g., screwdriver). 2. Close the ejector lever manually. 3. Carefully pull the FLK 6 connector connection out of the base strip Figure 9 Connecting a system cable with FLK 6 connector connection To ensure reliable electrical contact is made when the MINI Analog multiplexer is mounted in any position, the FLK 6 connector connection must be equipped with an engagement catch in accordance with IEC Figure Disconnecting a system cable with FLK 6 connector connection Connection/application example. Monitoring motor temperatures Controller x Analog IN 8xAnalog IN MINI MCR-SL-MUX.. AO Power ma DO DO DO Bit Channel Active Controller 3 x Digital IN 445_en_4 PHOENIX CONTACT

11 .2 Example of an alternative solution Old multiplexer solution MINI multiplexer solution Sensor Sensor2 Sensor3 Sensor4 SPS DI SPS AI Sensor Sensor2 Sensor3 Sensor4 SPS DI SPS AI 7A 78+ 6A 7B 6B 8+ 7C 6C 74+ 7D D+ D2+ A+ D- D2- A- D D D2+ A+ D- D2- A- Status Status Analog Bit Output Output 2 Output samples Sensor Sensor2 Multiplexers Sensor3 Sensor4 D+ OUT UI (5) GND (6) OUT UI (5) GND (6) OUT UI (5) GND (6) OUT UI (5) D2+ D- D2- PWR In IOut GND (6) Signal + (5) GND (6) Signal + (5) GND (6) Signal + (5) GND (6) Signal + (5) GND (6) Signal + GND Signal + GND Signal + GND () () () () () () () Signal + GND () Sensor Sensor2 Sensor3 Sensor4 Bit BIT BIT2 samples Sensor Sensor2 Sensor3 Sensor4 Analog Output MINI Analog Multiplexer Sensor Sensor2 Sensor3 Sensor4 Sensor4 Sensor Sensor2 Sensor3 445_en_4 PHOENIX CONTACT GmbH & Co. KG Blomberg Germany

MINI MCR-SL-RPS-I-I. Repeater power supply, active. Data sheet. 1 Description

MINI MCR-SL-RPS-I-I. Repeater power supply, active. Data sheet. 1 Description Repeater power supply, active Data sheet 09_en_0 PHOENIX CONTACT 0--0 Description The. mm wide... repeater power supply supplies transmitters in the field and electrically isolates the input signal from

More information

MINI MCR-SL-PT100-UI. Active resistance thermometer measuring transducer. Data sheet. 1 Description

MINI MCR-SL-PT100-UI. Active resistance thermometer measuring transducer. Data sheet. 1 Description Active resistance thermometer measuring transducer Data sheet 099_en_06 PHOENIX CONTACT 0-0- Description The 6. mm wide MINI MCR-SL-PT00-UI-... is a configurable, -way isolated temperature measuring transducer.

More information

MINI MCR-SL-CVS NC

MINI MCR-SL-CVS NC Constant voltage source Data sheet 105264_en_01 PHOENIX CONTACT 2013-04-03 1 Description Configurable constant voltage source for generating highprecision constant voltages. The voltage supply is also

More information

MINI MCR-SL-UI-2I. Configurable signal duplicator. Data sheet. 1 Description

MINI MCR-SL-UI-2I. Configurable signal duplicator. Data sheet. 1 Description Configurable signal duplicator Data sheet 102382_en_03 PHOENIX CONTACT 2012-05-02 1 Description The MINI MCR-SL-UI-2I(-SP)(-NC) configurable signal duplicator is used to electrically isolate, condition,

More information

MINI MCR-SL-PT100-UI-200

MINI MCR-SL-PT100-UI-200 Configurable temperature transducer for PT00 INTERFACE Data sheet 078_en_0 PHOENIX CONTACT 00-0-5 Description The MINI MCR-SL-PT00-UI-00... is a configurable -way isolated temperature transducer. It is

More information

RAD-DO8-IFS. I/O extension module, eight digital transistor outputs. Data sheet. 1 Description

RAD-DO8-IFS. I/O extension module, eight digital transistor outputs. Data sheet. 1 Description I/O extension module, eight digital transistor outputs Data sheet 105364_en_00 PHOENIX CONTACT 2013-03-26 1 Description The I/O extension module can be used in conjunction with Radioline wireless modules

More information

RAD-DI8-IFS. I/O extension module with 8 digital inputs or 2 pulse inputs. INTERFACE Data sheet. 1 Description

RAD-DI8-IFS. I/O extension module with 8 digital inputs or 2 pulse inputs. INTERFACE Data sheet. 1 Description I/O extension module with 8 digital inputs or 2 pulse inputs INTERFACE Data sheet 0483_en_00 PHOENIX CONTACT 203-04-05 Description The I/O extension module can be used in conjunction with Radioline wireless

More information

MINI MCR-SL-PT100-UI(-SP)(-NC)

MINI MCR-SL-PT100-UI(-SP)(-NC) Configurable Temperature Transducer for PT100 Data Sheet 04/2005 Functions MINI MCR-SL-PT100-UI(-SP)(-NC) is a configurable 3-way isolated temperature measuring transducer. It is suitable for the connection

More information

RAD-DOR4-IFS. I/O extension module, 4 digital relay outputs. INTERFACE Data sheet. 1 Description

RAD-DOR4-IFS. I/O extension module, 4 digital relay outputs. INTERFACE Data sheet. 1 Description I/O extension module, 4 digital relay outputs INTERFACE Data sheet 104834_en_01 PHOENIX CONTACT 2013-01-21 1 Description The RAD-DOR4-IFS I/O extension module can be used in conjunction with Radioline

More information

ETD-BL-1T-OFF-CC- 10S

ETD-BL-1T-OFF-CC- 10S Timer relay with off delay (with control contact) and adjustable time Data sheet 103617_en_03 1 Description PHOENIX CONTACT - 2013-09-16 Features Compact timer relay in 6.2 mm housing for controlling time

More information

MINI MCR-SL-UI-2I(-SP)(-NC)

MINI MCR-SL-UI-2I(-SP)(-NC) Data Sheet 03/2005 Product Description Features Configurable signal duplicator MINI MCR-SL-UI-2I(-SP)(-NC) is used to electrically isolate, condition, amplify, and filter analog standard signals. On the

More information

MINI MCR-SL-UI-2I-NC. Extract from the online catalog. Order No.:

MINI MCR-SL-UI-2I-NC. Extract from the online catalog. Order No.: Extract from the online catalog MINI MCR-SL-UI-2I-NC Order No.: 2864176 4-way signal duplicator for electrical isolation and duplication of analog signals with screw connection, standard configuration

More information

PHOENIX CONTACT Pin. SUBCON-PLUS M ARCNET, MULTI/MININET (B&R), SYSTEM 2003 (B&R), P-NET SUCONET K1, K2 (EATON/Moeller),

PHOENIX CONTACT Pin. SUBCON-PLUS M ARCNET, MULTI/MININET (B&R), SYSTEM 2003 (B&R), P-NET SUCONET K1, K2 (EATON/Moeller), Fast connector with screw terminal block connection for fieldbus systems Data sheet 00287_en_02 PHOENIX CONTACT 207-04-2 Description The SUBCON-PLUS/... D-SUB series is specifically designed for use in

More information

SUBCON-PLUS-PROFIB...

SUBCON-PLUS-PROFIB... Fast connector for PROFIBUS systems Data sheet 101610_en_10 PHOENIX CONTACT 2017-03-27 1 Description The SUBCON-PLUS-PROFIB... D-SUB series is specifically designed for use in PROFIBUS systems up to 12

More information

MINI MCR-2-U-I4(-PT) 3-way signal conditioner. Data sheet. 1 Description

MINI MCR-2-U-I4(-PT) 3-way signal conditioner. Data sheet. 1 Description 3-way signal conditioner Data sheet 106012_en_02 PHOENIX CONTACT 2016-02-19 1 Description The standard signal 3-way signal conditioner with pluggable connection technology is used to electrically isolate,

More information

PI-EX-ME-2NAM/COC-24VDC

PI-EX-ME-2NAM/COC-24VDC Ex-i NAMUR Isolation Amplifier, With Intrinsically Safe Input and Relay Output, PDT, Two-Channel, 4 V DC Supply INTERFACE Data Sheet 0033_0_en PHOENIX CONTACT - /007 Description The PI-EX-ME-NAM/COC-4VDC

More information

PHOENIX CONTACT - 12/2007

PHOENIX CONTACT - 12/2007 Ex-i NAMUR Isolation Amplifier, With Intrinsically Safe Input and Active Transistor Output, Two-Channel INTERFACE Data Sheet 0943_00_en PHOENIX CONTACT - /007 Description The PI-EX-ME-NAM/TO-A is a two-channel

More information

PHOENIX CONTACT - 05/2007

PHOENIX CONTACT - 05/2007 Ex Universal Module Carrier (Motherboard) for Accommodating 3-Wire Measuring Transducers, Intrinsically Safe, for a Maximum of 8 PI Ex Modules INTERFACE Data Sheet 103030_00_en PHOENIX CONTACT - 05/2007

More information

PI-EX-ME-2NAM/COC-120VAC

PI-EX-ME-2NAM/COC-120VAC PI-EX-ME-NAM/COC-0VAC Ex-i NAMUR Isolation Amplifier, With Intrinsically Safe Input and Relay Output, PDT, Two-Channel, 0 V AC Supply INTERFACE Data Sheet 0944_00_en PHOENIX CONTACT - 0/008 Description

More information

MACX MCR-SL-(2)I-2)I-ILP(-SP)

MACX MCR-SL-(2)I-2)I-ILP(-SP) Passive isolator, one and two channel Data sheet 106893_en_01 PHOENIX CONTACT 2015-12-07 1 Description The single- or dual-channel input loop powered 2-way isolator with plug-in connection technology is

More information

Extract from the online catalog

Extract from the online catalog Please note that the data given here has been taken from the online catalog. For comprehensive information and data, please refer to the user documentation at http://www.download.phoenixcontact.com. The

More information

RAD-DAIO6-IFS. I/O extension module, 1 analog input/output, 2 digital wide-range inputs/outputs. INTERFACE Data sheet.

RAD-DAIO6-IFS. I/O extension module, 1 analog input/output, 2 digital wide-range inputs/outputs. INTERFACE Data sheet. I/O extension module, 1 analog input/output, 2 digital wide-range inputs/outputs INTERFACE Data sheet 104832_en_01 PHOENIX CONTACT 2013-01-21 1 Description The RAD-DAIO6-IFS I/O extension module can be

More information

MACX MCR-EX-SD LP(-SP)

MACX MCR-EX-SD LP(-SP) Intrinsically safe solenoid driver for Group IIC gases, loop-powered, current limit 48 ma INTERFACE Data sheet 103468_en_01 PHOENIX CONTACT - 08/2008 1 Description The solenoid driver MACX MCR-EX-SD-24-48-LP(-SP)

More information

Extract from the online catalog

Extract from the online catalog Please note that the data given here has been taken from the online catalog. For comprehensive information and data, please refer to the user documentation at http://www.download.phoenixcontact.com. The

More information

PHOENIX CONTACT - 01/2008

PHOENIX CONTACT - 01/2008 Ex Basic Terminal Blocks for Intrinsically Safe Signals With Knife Disconnection and Test Connections INTERFACE Data Sheet 102957_00_en PHOENIX CONTACT - 01/2008 1 Description PI-EX-TB and PI-EX-TB/T Ex

More information

MINI MCR-SL-UI-REL(-SP)

MINI MCR-SL-UI-REL(-SP) Configurable Threshold Value Switch Data Sheet 11/2004 Method of Operation The configurable 3-way threshold value switch MINI MCR-SL-UI-REL(-SP) is used to control and monitor analog standard signals.

More information

PSR-PS21. SIL coupling relay. Data sheet. 1 Description

PSR-PS21. SIL coupling relay. Data sheet. 1 Description SIL coupling relay Data sheet 106253_en_00 PHOENIX CONTACT 2015-03-13 1 Description Intended Use The SIL coupling relay can be used for power adaptation and electrical isolation in high and low-demand

More information

PHOENIX CONTACT - 02/2008

PHOENIX CONTACT - 02/2008 Ex-i solenoid driver for Group IIC gases, loop-powered, pluggable INTERFACE Data Sheet 103211_00_en PHOENIX CONTACT - 02/2008 1 Description The solenoid driver PI-EX-SD-21-25 links a signaling device installed

More information

RAD-WHG/WLAN-XD. WirelessHART gateway with integrated WLAN (802.11b/g) INTERFACE Data Sheet 2720_en_C. 2 Features. 1 Description

RAD-WHG/WLAN-XD. WirelessHART gateway with integrated WLAN (802.11b/g) INTERFACE Data Sheet 2720_en_C. 2 Features. 1 Description WirelessHART gateway with integrated WLAN (802.11b/g) INTERFACE Data Sheet 2720_en_C 1 Description PHOENIX CONTACT 2011-06-07 2 Features The RAD-WHG/WLAN-XD is a WirelessHART gateway with integrated 802.11b/g

More information

SATEL-LP-AI4. I/O extension module, 4 analog current inputs. Data sheet. 1 Description

SATEL-LP-AI4. I/O extension module, 4 analog current inputs. Data sheet. 1 Description I/O extension module, analog current inputs Data sheet 1069_en_00 SATEL 015-10-7 1 Description The I/O extension module can be used in conjunction with SATEL-LP wireless modules. In a station structure,

More information

RAD-PT100-4-IFS. I/O extension module, 4 temperature inputs (Pt 100) Data sheet. 1 Description

RAD-PT100-4-IFS. I/O extension module, 4 temperature inputs (Pt 100) Data sheet. 1 Description R-PT100-4- I/O extension module, 4 temperature inputs (Pt 100) ata sheet 105366_en_00 PHOENIX CONTCT 2013-12-06 1 escription The R-PT100-4- I/O extension module can be used in conjunction with Radioline

More information

MACX MCR-EX-SL-NAM-R(-SP)

MACX MCR-EX-SL-NAM-R(-SP) Intrinsically safe NAMUR isolating amplifier with relay output INTERFACE Data sheet 03463_en_00 PHOENIX CONTACT - 08/2008 Description The NAMUR MACX MCR-EX-SL-NAM-R(-SP) isolating amplifier has been designed

More information

MACX MCR-EX-SL-NAM-2RO(-SP)

MACX MCR-EX-SL-NAM-2RO(-SP) Intrinsically safe NAMUR isolating amplifier with two relay outputs INTERFACE Data sheet 03465_en_00 PHOENIX CONTACT - 08/008 Description The NAMUR MACX MCR-EX-SL-NAM-RO(-SP) isolating amplifier has been

More information

Redundancy Module QUINT-DIODE/40

Redundancy Module QUINT-DIODE/40 Redundancy Module QUT DIODE provides: 00% decoupling of power supplies connected in parallel Can be installed in potentially explosive areas Load currents up to 60 A supported Easy assembly by snapping

More information

MINI MCR-2-RTD-UI(-PT)(-C)

MINI MCR-2-RTD-UI(-PT)(-C) Temperature transducers for resistance thermometers and remote resistance-type sensors Data sheet 106015_en_02 PHOENIX CONTACT 2016-03-14 1 Description Configurable 3-way isolated temperature transducer

More information

MACX MCR-EX-SL-2NAM-T(-SP)

MACX MCR-EX-SL-2NAM-T(-SP) NAMUR signal conditioner, Ex-i, 2-channel, with transistor output Data sheet 103753_en_00 PHOENIX CONTACT 2014-08-19 1 Description The 2-channel NAMUR signal conditioner MACX MCR-EX-SL-2NAM-T(-SP) has

More information

PSR-PC20. SIL coupling relay. Data sheet. 1 Description

PSR-PC20. SIL coupling relay. Data sheet. 1 Description SIL coupling relay Data sheet 106255_en_00 PHOENIX CONTACT 2015-03-13 1 Description Intended Use The PSR-PC20 SIL coupling relay can be used for power adaptation and electrical isolation in high and low-demand

More information

Loop-powered Transmitter for Thermocouple Type K (NiCr-Ni)

Loop-powered Transmitter for Thermocouple Type K (NiCr-Ni) Data sheet 302040_en MTP300i-SIL-K Loop-powered Transmitter for Thermocouple Type K (NiCr-Ni) Properties 2-wire temperature transmitter for DIN rails Galvanic isolated TC-input with cold-junction compensation

More information

MACX MCR-EX-SL-RPSSI-I(-SP)

MACX MCR-EX-SL-RPSSI-I(-SP) Repeater power supply and input isolating amplifier, Ex-i Data sheet 103568_en_02 PHOENIX CONTACT 2015-03-26 1 Description The repeater power supply and input signal conditioner is designed for the intrinsically

More information

Power manual for MACX Analog, MACX Analog Ex, MACX PL, MINI Analog, and MINI Analog Pro signal conditioners. User manual

Power manual for MACX Analog, MACX Analog Ex, MACX PL, MINI Analog, and MINI Analog Pro signal conditioners. User manual Power manual for MACX Analog, MACX Analog Ex, MACX PL, MINI Analog, and MINI Analog Pro signal conditioners User manual User manual Power manual for MACX Analog, MACX Analog Ex, MACX PL, MINI Analog, and

More information

TRIO-DIODE/12-24DC/2X10/1X20

TRIO-DIODE/12-24DC/2X10/1X20 Redundancy module INTERFACE Data sheet 104278_en_00 1 Description PHOENIX CONTACT 20100423 Features TRIO DIODE is the DINrail mountable redundancy module from the TRIO POWER product range. Using the redundancy

More information

Termination Board FC-GPCS-SAI16-PF. Features. Assembly. Function. Connection. SAI-1620m HART 24 V DC (I), 24 V DC (II) Fault. Zone 0, 1, 2 Div.

Termination Board FC-GPCS-SAI16-PF. Features. Assembly. Function. Connection. SAI-1620m HART 24 V DC (I), 24 V DC (II) Fault. Zone 0, 1, 2 Div. Features Assembly System board for Honeywell Safety Manager For 6-channel AI card SAI-60m For 6 modules Recommended module: HiC05 (AI) 4 V DC supply Hazardous area: pluggable screw terminals, blue Non-hazardous

More information

QUINT-BUFFER/24DC/24DC/40

QUINT-BUFFER/24DC/24DC/40 Buffer module Data sheet 105496_en_01 PHOENIX CONTACT 2013-11-01 1 Description The QUINT BUFFER buffer module combines the electronic switchover unit and power storage in the same housing. The buffer module

More information

MACX MCR-EX-SL-RPSS-2I-2I

MACX MCR-EX-SL-RPSS-2I-2I 2channel repeater power supply, Ex i Data sheet 105571_en_00 PHOENIX CONTACT 20140513 1 Description The 2channel repeater power supply is designed for the operation of intrinsically safe (Exi) 2wire measuring

More information

MACX MCR-EX-SL-RTD-I...

MACX MCR-EX-SL-RTD-I... Temperature transducer with intrinsically safe input for resistance thermometers and resistance-type sensors INTERFACE Data Sheet 103945_en_00 PHOENIX CONTACT 2009-12-04 1 Description The programmable

More information

This data sheet is only valid in association with the IL SYS INST UM E user manual.

This data sheet is only valid in association with the IL SYS INST UM E user manual. Inline analog input terminal, 4 inputs for connecting voltage signals Data sheet 8081_en_01_C01 PHOENIX CONTACT 2015-04-14 1 Description The terminal is designed for use within an Inline station. It is

More information

REDUNDANCY MODULE TSP-REM360 AND TSP-REM600

REDUNDANCY MODULE TSP-REM360 AND TSP-REM600 REDUNDANCY MODULE TSP-REM360 AND TSP-REM600 Operating Instructions Seite 1 Dimensions drawings: TSP-REM360 Weight: 0.882lb Gewicht: 0.40kg Seite 2 Dimensions drawings: TSP-REM600 Bottom view Top view Side

More information

Technical Data. General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm. Short-circuit protection

Technical Data. General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm. Short-circuit protection NCN-FK-N-V-V 002 Model Number NCN-FK-N-V-V Features Direct mounting on standard actuators Compact and stable housing with terminal compartment connection Fixed setting EC-Type Examination Certificate TÜV99

More information

PSI-MODEM-SHDSL/SERIAL

PSI-MODEM-SHDSL/SERIAL PSI-MODEM-/SERIAL -SERIAL permanent line modem Data sheet 104460_en_02 PHOENIX CONTACT 2011-12-06 1 Description The industrial SERIAL permanent line modem enables broadband networking of serial devices

More information

Termination Board FC-GPCS-RIO16-PF. Features. Assembly. Function. Connection USIO/UPIO 24 V DC (I), 24 V DC (II) Fault. Zone 0, 1, 2 Div.

Termination Board FC-GPCS-RIO16-PF. Features. Assembly. Function. Connection USIO/UPIO 24 V DC (I), 24 V DC (II) Fault. Zone 0, 1, 2 Div. Features Assembly System board for Honeywell Universal Safety IO System board for Honeywell Universal Process IO For 6-channel cards USIO and UPIO For 6 modules Recommended modules: HiC8R (DI), HiC85R

More information

Operating instructions (Safety-related part ATEX and IECEx) Inductive NAMUR sensors NN504A NN505A NN506A NN507A /00 08/2015

Operating instructions (Safety-related part ATEX and IECEx) Inductive NAMUR sensors NN504A NN505A NN506A NN507A /00 08/2015 Operating instructions (Safety-related part ATEX and IECEx) Inductive NAMUR sensors NN504A NN505A NN506A NN507A 80013497/00 08/015 Remarks for safe use in hazardous areas Functions and features Use in

More information

onlinecomponents.com

onlinecomponents.com Repeater for RS-485 2-Wire Systems INTERFACE Data Sheet 102964_C01_en 1 Description The PSI-REP-RS485W2 DIN-rail mountable, modular RS-485 repeater is designed to meet the high requirements associated

More information

PHOENIX CONTACT Features

PHOENIX CONTACT Features Electronic monitoring relay for temperature monitoring Data sheet 107385_en_00 1 Description PHOENIX CONTACT - 2016-05-10 Features Safety and system availability requirements are constantly on the increase

More information

PSM-ME-RS485/RS485-P. Repeater for RS wire bus systems. Data sheet. 1 Description

PSM-ME-RS485/RS485-P. Repeater for RS wire bus systems. Data sheet. 1 Description Repeater for RS-485 2-wire bus systems Data sheet 100273_en_06 PHOENIX CONTACT 2016-09-09 1 Description The PSM-ME-RS485/RS485-P RS-485 repeater was developed for the high requirements of fieldbus systems.

More information

VL BPC MINI. A configurable industrial computer platform Intel Atom Z510PT CMAT IPC Module Option [I28] AUTOMATION Data Sheet 2930_en_A.

VL BPC MINI. A configurable industrial computer platform Intel Atom Z510PT CMAT IPC Module Option [I28] AUTOMATION Data Sheet 2930_en_A. A configurable industrial computer platform Intel Atom Z0PT CMAT IPC Module Option [I8] AUTOMATION Data Sheet 90_en_A Description PHOENIX CONTACT 0-0-0 Features The VL BPC MINI is an embedded box PC and

More information

ILBIB24DO16-DSUB. Inline Block IO Module for INTERBUS With 16 Digital Outputs; Bus Connection via D-SUB Connectors

ILBIB24DO16-DSUB. Inline Block IO Module for INTERBUS With 16 Digital Outputs; Bus Connection via D-SUB Connectors Inline Block IO Module for INTERBUS With 16 Digital Outputs; Bus Connection via D-SUB Connectors AUTOMATIONWORX Data Sheet 7119_en_02 PHOENIX CONTACT - 03/2007 Description The ILB IB 24 DO16-DSUB module

More information

PSI-MODEM-SHDSL/PB. Broadband PROFIBUS extender, SHDSL PROFIBUS leased line modem. Data sheet _en_03. 1 Description. 1.

PSI-MODEM-SHDSL/PB. Broadband PROFIBUS extender, SHDSL PROFIBUS leased line modem. Data sheet _en_03. 1 Description. 1. PSI-MODEM-/PB Broadband PROFIBUS extender, PROFIBUS leased line modem Data sheet 104396_en_03 1 Description PHOENIX CONTACT 2013-08-21 1.1 Features The PROFIBUS extender can be used to easily network PROFIBUS

More information

Inductive dual sensor For rotary actuators NI4-DSU35TC-2Y1X2/S933

Inductive dual sensor For rotary actuators NI4-DSU35TC-2Y1X2/S933 ATEX category II 2 G, Ex zone 1 ATEX category II 1 D, Ex zone 20 SIL2 as per IEC 61508 Rectangular, housing DSU35 Plastic, PP-GF30-VO Two outputs for monitoring the position of rotary actuators Mounting

More information

Inductive sensor BI1.5-EG08-Y1-H1341

Inductive sensor BI1.5-EG08-Y1-H1341 ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1

More information

PHOENIX CONTACT - 07/2006

PHOENIX CONTACT - 07/2006 Buffer module with maintenance-free capacitor-based power storage device INTERFACE Data sheet 102035_03_en PHOENIX CONTACT - 07/2006 Description Short-term mains interruptions are bridged by QUINT BUFFER,

More information

Inductive sensor NI3-EG08K-Y1-H1341

Inductive sensor NI3-EG08K-Y1-H1341 ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 as per IEC 61508 Threaded barrel, M8 x 1 Stainless steel, 1.4427 SO DC 2-wire, nom. 8.2 VDC Output acc. to DIN EN 60947-5-6 (NA- MUR)

More information

Inductive sensor Dual sensors with extended temperature range NI4-DSU35TC-2Y1X2/S97

Inductive sensor Dual sensors with extended temperature range NI4-DSU35TC-2Y1X2/S97 ATEX category II 2 G, Ex zone 1 ATEX category II 1 D, Ex-zone 20 for temperatures up to -25 C SIL2 acc. to IEC 61508 Rectangular, housing DSU35 Plastic, PP-GF30-VO Two outputs for monitoring the position

More information

PSR-MS60. Safety relay for emergency stop, safety door and light grid monitoring. Data sheet. 1 Description

PSR-MS60. Safety relay for emergency stop, safety door and light grid monitoring. Data sheet. 1 Description SILCL IEC 62061 Safety relay for emergency stop, safety door and light grid monitoring Data sheet 106171_en_01 PHOENIX CONTACT 2015-05-19 1 Description Intended Use The PSR-MS60 safety relay can be used

More information

ILBPB24DO32. Inline Block IO Module for PROFIBUS With 32 Digital Outputs. AUTOMATIONWORX Data Sheet 6889_en_04. Description

ILBPB24DO32. Inline Block IO Module for PROFIBUS With 32 Digital Outputs. AUTOMATIONWORX Data Sheet 6889_en_04. Description Inline Block IO Module for PROFIBUS With 32 Digital Outputs AUTOMATIONWORX Data Sheet 6889_en_04 Description PHOENIX CONTACT - 03/2007 & & ' ) The ILB PB 24 DO32 module is designed for use within a PROFIBUS

More information

Signal processor MS96 for flow sensors MS96-11EX0-R/230VAC

Signal processor MS96 for flow sensors MS96-11EX0-R/230VAC MS96-11EX0-R/230VAC ATEX category II (1) G, Ex Zone 0 ATEX category II (1) D, Ex Zone 20 single-channel signal processor MS96 for connection of an intrinsically safe flow control sensor in zone 0 adjustment

More information

FLM DI 8 M12. Function. Fieldline Modular Device With Eight Digital Inputs. Data Sheet

FLM DI 8 M12. Function. Fieldline Modular Device With Eight Digital Inputs. Data Sheet Fieldline Modular Device With Eight Digital Inputs Data Sheet 697000 02/2004 This data sheet is only valid in association with the FLS FLM SYS INST UM E user manual or the user manual for your bus system

More information

Inductive sensor BI5-EM18-Y1X-H1141

Inductive sensor BI5-EM18-Y1X-H1141 ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1

More information

PHOENIX CONTACT - 08/2009. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

PHOENIX CONTACT - 08/2009. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area. Primary-switched power supply for building automation INTERFACE Data sheet 103505_en_02 1 Description PHOENIX CONTACT - 08/2009 Features STEP POWER power supply units for building automation The new STEP

More information

VL BPC MINI. A configurable industrial computer platform. Data sheet 2930_en_F. 1 Description. 2 Features

VL BPC MINI. A configurable industrial computer platform. Data sheet 2930_en_F. 1 Description. 2 Features A configurable industrial computer platform Data sheet 90_en_F Description PHOENIX CONTACT 0-08- Features The VL BPC MINI is an embedded box PC and is part of the Valueline family of industrial computers.

More information

PHOENIX CONTACT - 05/2008. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

PHOENIX CONTACT - 05/2008. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area. Primary switched power supply, 1-phase, output current: 5 A ITERFACE Data Sheet 103349_en_00 1 Description PHOEIX COTACT - 05/2008 Features TRIO POWER is the DI-rail-mountable power supply unit with basic

More information

Magnetic Field Sensor Magnetic-inductive Proximity Sensor BIM-M12E-Y1X-H1141

Magnetic Field Sensor Magnetic-inductive Proximity Sensor BIM-M12E-Y1X-H1141 ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1

More information

Inductive sensor BI1.5-EG08-Y1-H1341

Inductive sensor BI1.5-EG08-Y1-H1341 ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1

More information

Inductive sensor For rotary actuators NI4-DSU35TC-2Y1X2

Inductive sensor For rotary actuators NI4-DSU35TC-2Y1X2 ATEX category II 2 G, Ex zone 1 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1

More information

Magnetic Field Sensor for pneumatic cylinders BIM-INT-Y1X-H1141

Magnetic Field Sensor for pneumatic cylinders BIM-INT-Y1X-H1141 ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1

More information

PHOENIX CONTACT - 01/2010. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

PHOENIX CONTACT - 01/2010. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area. Uninterruptible power supply with integrated power supply unit INTERFACE Data sheet 104211_en_00 1 Description PHOENIX CONTACT - 01/2010 Features The MINI-DC-UPS provide an uninterruptible DC voltage both

More information

Inductive sensor For rotary actuators NI4-DSU35-2Y1X2-H1140

Inductive sensor For rotary actuators NI4-DSU35-2Y1X2-H1140 ATEX category II 2 G, Ex zone 1 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1

More information

Inductive sensor For rotary actuators NI4-DSU35TC-2Y1X2/S933

Inductive sensor For rotary actuators NI4-DSU35TC-2Y1X2/S933 ATEX category II 2 G, Ex zone 1 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1

More information

STEP-PS/1AC/24DC/1.75

STEP-PS/1AC/24DC/1.75 Primary-switched power supply, 1 AC, output current 1.75 A INTERFACE Data Sheet 103506_en_00 1 Description PHOENIX CONTACT - 05/2008 Features STEP POWER power supply units for building automation The new

More information

Termination Board. HiCTB08-SCT-44C-SC-RA. Features. Assembly. Function. Connection. 24 V DC (I), 24 V DC (II), Fault. Zone 0, 1, 2 Div.

Termination Board. HiCTB08-SCT-44C-SC-RA. Features. Assembly. Function. Connection. 24 V DC (I), 24 V DC (II), Fault. Zone 0, 1, 2 Div. Termination Board HiCTB08-SCT-C-SC-RA Features Assembly For 8 modules V DC supply Supported signal types: DI/DO/AI/TI/AO Hazardous area: screw terminals, blue Safe area: screw terminals, black Function

More information

Magnetic field sensor Magnetic-inductive Proximity Sensor BIM-M12E-Y1X

Magnetic field sensor Magnetic-inductive Proximity Sensor BIM-M12E-Y1X ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 as per IEC 61508 Threaded barrel, M12 x 1 Chrome-plated brass Rated operating distance 90 mm with DMR31-15-5 magnet DC 2-wire, nom.

More information

Technical Data. General specifications Switching element function PNP NO/NC Rated operating distance s n 5 mm

Technical Data. General specifications Switching element function PNP NO/NC Rated operating distance s n 5 mm Model Number Features 5 mm flush ATEX-approval for zone and zone Accessories BF 8 Mounting flange, 8 mm EXG-8 Quick mounting bracket with dead stop Technical Data specifications Switching element function

More information

Operating instructions. Speed monitor D / / 2014

Operating instructions. Speed monitor D / / 2014 Operating instructions Speed monitor D200 80005257 / 00 05 / 2014 Contents 1 Preliminary note...4 1.1 Symbols used...4 1.2 Warning signs used...4 2 Safety instructions...5 2.1 General...5 2.2 Target group...5

More information

SUNCLIX Connection technology for photovoltaics

SUNCLIX Connection technology for photovoltaics SUNCLIX Connection technology for photovoltaics Connection technology for photovoltaics Are you looking for innovative and reliable connection technology for your PV modules, inverters or the complete

More information

Magnetic Field Sensor Magnetic-inductive Proximity Sensor BIM-EG08-Y1X-H1341

Magnetic Field Sensor Magnetic-inductive Proximity Sensor BIM-EG08-Y1X-H1341 ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1

More information

PHOENIX CONTACT - 06/2007. DANGER OF EXPLOSION! Remove an item only when it is not connected to power or if it is located in the non-explosive area.

PHOENIX CONTACT - 06/2007. DANGER OF EXPLOSION! Remove an item only when it is not connected to power or if it is located in the non-explosive area. Primary switched power supply, 3-phase, output current: 40 A INTERFACE Data Sheet 102782_01_en PHOENIX CONTACT - 06/2007 Description TRIO POWER is the rail mountable 24 V power supply unit with basic functions.

More information

VL BPC 100. Valueline configurable box PC. Data sheet 3063_en_E. 1 Description. 2 Features

VL BPC 100. Valueline configurable box PC. Data sheet 3063_en_E. 1 Description. 2 Features Valueline configurable box PC Data sheet 0_en_E Description PHOENIX CONTACT 0-07- Features The VL BPC 000 is a configurable box PC that can be mounted either directly on a wall or on a DIN rail. The VL

More information

IB ST 24 AO 4/EF. INTERBUS-ST analog output module, 4 outputs, 0-10 V, ±10 V, 0-20 ma, 4-20 ma. Data sheet. 1 Description

IB ST 24 AO 4/EF. INTERBUS-ST analog output module, 4 outputs, 0-10 V, ±10 V, 0-20 ma, 4-20 ma. Data sheet. 1 Description INTERBUS-ST analog output module, 4 outputs, 0-10 V, ±10 V, 0-20 ma, 4-20 ma Data sheet 105597_en_01 PHOENIX CONTACT 2014-10-24 1 Description The module is designed for use within an ST station. It is

More information

FL SWITCH SFN 5TX. Extract from the online catalog. Order No.:

FL SWITCH SFN 5TX. Extract from the online catalog. Order No.: Extract from the online catalog FL SWITCH SFN 5TX Order No.: 2891152 Ethernet switch, 5 TP RJ45 ports, automatic detection of data transmission rate of 10 or 100 mbps (RJ45), autocrossing function Commercial

More information

PHOENIX CONTACT

PHOENIX CONTACT Fast connection connector for PROFIBUS systems Data sheet 101610_en_07 PHOENIX CTACT 2011-11-17 1 Description The D-SUB series SUBC-PLUS-PROFIB is specially designed for use in PROFIBUS systems up to 12

More information

Diffuse reflection light scanner with background suppression. Dimensioned drawing

Diffuse reflection light scanner with background suppression. Dimensioned drawing Specifications and description HRTR 55 Ex Diffuse reflection light scanner with background suppression Dimensioned drawing en 01-2011/05 50113748 1 khz 5 400mm 200mm with black-white error < 10% 10-30

More information

QUINT-PS-3x AC/24DC/10

QUINT-PS-3x AC/24DC/10 3-Phase Primary-Switched Power Supply Unit INTERFACE Data Sheet PHOENIX CONTACT - 12/2005 Description QUINT POWER devices are 60...960 W power supply units for universal use. This is ensured by the wide-range

More information

Operating Instructions (Translation) 3. Safety Information. 1. Description. 2. Explosion Protection. Supply module Type 17-21BB-170x

Operating Instructions (Translation) 3. Safety Information. 1. Description. 2. Explosion Protection. Supply module Type 17-21BB-170x 1. Description The supply module was developed specially for direct mounting in hazardous areas in Zone 1 and 21 and is ATEX-certified. The supply module is a permanently installed piece of electrical

More information

Valueline Industrial PC

Valueline Industrial PC A configurable industrial computer platform AUTOMATION Data Sheet 2643_en_F 1 Description PHOENIX CONTACT 2011-07-15 2 Features The Valueline Industrial PC (VL IPC) product line is a configurable industrial

More information

BVS 17 ATEX E 117 X / IECEx BVS X Types 3320, 3321, 3323, 3360, 3361, 3363 AE3320, AE3321, AE3323, AE3360, AE3361, AE3363

BVS 17 ATEX E 117 X / IECEx BVS X Types 3320, 3321, 3323, 3360, 3361, 3363 AE3320, AE3321, AE3323, AE3360, AE3361, AE3363 BVS 17 ATEX E 117 X / IECEx BVS 17.0100X Types 3320, 3321, 3323, 3360, 3361, 3363 AE3320, AE3321, AE3323, AE3360, AE3361, AE3363 Electromotive control valve with ATEX approval and IECEx approval Elektromotorisches

More information

FL MC 2000E (SM40) LC

FL MC 2000E (SM40) LC IEC 61850 fiber optic converter with LC fiber optic connection (1310 nm) to convert 100Base-Tx to single- or multi-mode fiber glass Data sheet 3205_en_C 1 Description PHOENIX CONTACT 2014-04-04 2 Features

More information

Assembly MAU. MUX 4 Channels 8 Channels Zone 1

Assembly MAU. MUX 4 Channels 8 Channels Zone 1 Multi-Input/Output Device for Cabinet Installation Features Assembly For discrete inputs and outputs Installation in Zone 1/Div. 1, intrinsically safe Sensors in Zone 0/Div. 1 Connection to fieldbus acc.

More information

MINI-PS AC/10-15DC/8

MINI-PS AC/10-15DC/8 Primary-Switched Power Supply, Narrow Design Data Sheet 08/2004 MINI POWER provides: An extra narrow design, with widths of 22.5 mm, 45 mm, and 67.5 mm (0.886, 1.772, and 2.657 in.) Global use due to a

More information

PHOENIX CONTACT - 05/2008. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

PHOENIX CONTACT - 05/2008. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area. Primary switched power supply, 1-phase, output current: 5 A ITERFACE Data Sheet 102777_en_03 1 Description PHOEIX COTACT - 05/2008 Features TRIO POWER is the DI-rail-mountable power supply unit with basic

More information

SINAMICS G130. Voltage Sensing Module 10 (VSM10) Operating Instructions 05/2010 SINAMICS

SINAMICS G130. Voltage Sensing Module 10 (VSM10) Operating Instructions 05/2010 SINAMICS SINAMICS G130 Operating Instructions 05/2010 SINAMICS s Safety information 1 General 2 SINAMICS SINAMICS G130 Voltage Sensing Module 10 (VSM10) Mechanical installation 3 Electrical installation 4 Technical

More information

BVS 17 ATEX E 117 X / IECEx BVS X Types 3320, 3321, 3323, 3360, 3361, 3363 AE3320, AE3321, AE3323, AE3360, AE3361, AE3363

BVS 17 ATEX E 117 X / IECEx BVS X Types 3320, 3321, 3323, 3360, 3361, 3363 AE3320, AE3321, AE3323, AE3360, AE3361, AE3363 BVS 17 ATEX E 117 X / IECEx BVS 17.0100X Types 3320, 3321, 3323, 3360, 3361, 3363 AE3320, AE3321, AE3323, AE3360, AE3361, AE3363 Electromotive control valve with ATEX approval and IECEx approval Elektromotorisches

More information