1 AS-i Master for S7-100 Catalog IC 10 N December 011 SIRIUS Answers for industry.

2 Related catalogs Industrial Controls IC 10 SIRIUS E86060-K1010-A101-A-7600 Safety Integrated SI 10 Safety Technology for Factory Automation Contents Industrial communication Controls Protection equipment Load feeders and motor starters Monitoring and control devices Safety control devices Detecting devices Commanding and signaling devices Parameterization, configuration and visualization Transformers and power supplies Heating controls Components for charging electric vehicles Detecting Evaluation / Communication Reacting E86060-K7010-A101-A-7600 Industrial Communication SIMATIC NET E86060-K6710-A101-B IK PI PROFINET / Industrial Ethernet PROFIBUS SIMATIC ET 00 Distributed I/O SIMATIC Ident Identification Systems IO-Link Industrial Wireless Communication Industrial Remote Communication ECOFAST Products for Automation CA 01 and Drives Interactive Catalog All products of automation, drives and installation technology, including those in the catalogs listed above. DVD: E86060-D4001-A510-D Industry Mall Information and Ordering Platform in the Internet: All products of automation, drives and installation technology, including those in the catalogs listed above. Catalog PDF Internet: Information and download center of Industry Automation and Drive Technologies. Registered trademarks Technical Assistance All product designations may be registered trademarks or product names of Siemens AG or other supplying companies. Third parties using these trademarks or product names for their own purposes may infringe upon the rights of the trademark owners. Further information about industrial controls: Expert technical assistance for Industrial controls: Tel.: +49 (911) Fax: +49 (911) technicalassistance@siemens.com

3 SIRIUS AS-i Master for S7-100 Catalog IC 10 N December Introduction Industrial Communication 3 Controls Contactors and Contactor Assemblies for Starting Motors The products and systems listed in this catalog are manufactured/distributed using a certified quality management system which complies with EN ISO 9001 (for the Certificate Register Nos. see the Appendix to the catalog IC 10 01). The certificate is recognized in all IQNet countries. 4 Controls Contactors and Contactor Assemblies Special Applications 5 Controls Contactors and Contactor Assemblies Contactor Relays and Relays 6 Controls Soft Starters and Solid-State Switching Devices 7 Protection Equipment For the latest updates of this catalog, please visit our Industry Mall: Contact your local Siemens sales office for further information Siemens AG 01 8 Load Feeders and Motor Starters for Operation in the Control Cabinet 9 Motor Starters for Operation in the Field, High Degree of Protection 10 Monitoring and Control Devices 11 Safety Technology 1 Position Switches and Safety Switches 13 Commanding and Signaling Devices 14 Planning, Configuration and Visualizing for SIRIUS 15 Products for Specific Requirements 16 Appendix

4 Industry Mall Much more than a catalog. The Industry Mall. You have a catalog in your hands that will serve you well for selecting and ordering your products. But have you heard of the electronic online catalog (the Industry Mall) and all its benefits? Take a look around it sometime: Selecting Find your products in the structure tree, in the new "Bread-crumb" navigation or with the integral search machine with expert functions. Electronic configurators are also integrated into the Mall. Enter the various characteristic values and the appropriate product will be displayed with the relevant order numbers. You can save configurations, load them and reset them to their initial status. Ordering You can load the products that you have selected in this way into the shopping basket at a click of the mouse. You can create your own templates and you will be informed about the availability of the products in your shopping cart. You can load the completed parts lists directly into Excel or Word. Delivery status When you have sent the order, you will receive a short confirmation which you can print out or save. With a click on "Carrier", you will be directly connected to the website of the carrier where you can easily track the delivery status. Added value due to additional information So you have found your product and want more information about it? In just a few clicks of the mouse, you will arrive at the image data base, manuals and operating instructions. Create your own user documentation with My Documentation Manager. Also available are FAQs, software downloads, certificates and technical data sheets as well as our training programs. In the image database you will find, depending on the product, D/3D graphics, dimension drawings and exploded drawings, characteristic curves or circuit diagrams which you can download. Convinced? We look forward to your visit! Siemens IC 10 N 1/011

5 Ordering notes Things you should know about Catalog News IC 10 N The Catalog News IC 10 N contains all selection and order-relevant data. Delivery time class (DT) } Preferred type A working days B 1 week C 3 weeks D 6 weeks X On request Price units (PU) Preferred types are available immediately from stock, i. e. are dispatched within 4 hours. Normal quantities of the products are usually delivered within the specified time following receipt of your order at our branch. In exceptional cases, the actual delivery time may differ from that specified. The price unit defines the number of units, sets or meters to which the specified price and weight apply. Packaging sizes (PS) The packaging size defines the number, e. g. of units, sets or meters, for outer packaging. Only the quantity defined by the packaging size or a multiple thereof can be ordered! Price groups (PG) Each product is assigned to a price group. Dimensions All dimensions in mm. The delivery times apply up to the ramp at Siemens AG (products ready for dispatch). The transport times depend on the destination and type of shipping. The standard transport time for Germany is 1 day. The delivery time classes specified here represent the state of 10/010. They are permanently optimized. Up-to-date information can be found at For multi-unit packing and reusable packaging see Appendix in IC Siemens IC 10 N 1/011 3

6 Notes 4 Siemens IC 10 N 1/011

7 Industrial Communication Price groups PG 41B, 41H, 4C, 4D, 4F, 4J, 30, 50, 5K1, 5K, 5N3 / Introduction Introduction /4 Transmission technology /5 Communication overview specification /6 - Specification.0,.1 and 3.0 /7 - AS-i Power4V expansion Masters Masters for SIMATIC S7 /8 - CM 143- /10 - CP 43- /11 - CP 343-P / CP 343- Power supply units and data decoupling modules /13 power supply units Ch.15 4 V power supply units /14 S.5 data decoupling modules Data decoupling modules for S7-100 /16 - DCM 171 data decoupling module 1) See Catalog DA 11.1 More information is available on the Internet, see the opening information in IC 10 01, page 16 Siemens Siemens IC 10 IC N 10 1/011 N 1/011

8 Industrial Communication Siemens AG 01 Introduction Overview Order No. : Masters The master connects SIMATIC control systems to. It automatically organizes the data traffic on the cable and sees not only to processing the signals but also to performing the parameter setting, monitoring and diagnostics functions. Masters for SIMATIC S7 6GK7 Connection of up to 6 slaves 3RK7 Connection of up to 496 digital inputs and 496 outputs per master or network Integrated analog value transmission Simple configuration by adopting the actual configuration on the network Easy operation in the input/output address area of the SIMATIC S7 comparable to standard I/O modules Monitoring of the control supply voltage on the shaped cable Your advantage: Easy connection to SIMATIC S7-300, ET 00 M or SIMATIC S7-00 and CM 143- for SIMATIC S7-100 SIMATIC S7-100 Page /10 /10 CP 343-, CP 343-P for SIMATIC S7-300 CP 43- for SIMATIC S7-00 / Siemens IC 10 N 1/011

9 Industrial Communication Introduction : Power supply units and data decoupling modules IP0, 3 A power supply units generate a controlled direct voltage of 30 V DC with high stability and low residual ripple in conjunction with data decoupling. They are an integral component of the network and enable the simultaneous transmission of data and energy on one cable. In conjunction with data decoupling modules, can also be operated with standard power supply units. power supply units With wide performance spectrum from.6 to 8 A Degree of protection IP0 Separation of data and energy by means of the integrated data decoupling UL/CSA approval means the power supplies can be used worldwide.6 A version with output power restricted to max. 100 W (for use in NEC Class circuits) Certified for global use Integrated ground-fault and overload detection save the need for additional components and makes applications reliable Diagnostics memory, remote indication and remote RESET allow fast detection of faults in the system The ultra-wide input range enables single- and two-phase applications (8 A version) Your advantage: Optimum performance for each application Order No. Page 3RX9 /13 IP0, 8 A SITOP PSU100M, 4 V DC, 0 A S.5 data decoupling module 4 V power supply units Standard 4 V power supply units (SITOP) Performance spectrum.5 A to 40 A Overload and short-circuit proof in every performance class Add-on modules for signaling, redundancy, buffering and UPS Single-phase, two-phase and three-phase versions Your advantage: Economical alternatives in conjunction with data decoupling modules S.5 data decoupling modules Degree of protection IP0, narrow design.5 mm Supply of several AS-i networks with a single power supply unit Single and double data decoupling Operation with 4 V DC or 30 V DC Your advantage: Cost-effective installation of AS-i networks in conjunction with standard power supply units DCM 171 data decoupling module for SIMATIC S7-100 Simple data decoupling in IP 0 design Supply of several AS-i networks with a single power supply unit Operation with 4 V DC or 30 V DC Your advantage: Cost-effective installation of AS-i networks in conjunction with standard power supply units in the form of a SIMATIC S7-100 module 6EP Ch. 15 3RK1 /14 3RK7 /16 DCM 171 data decoupling module Note: Screw terminals Spring-type terminals Combicon connectors (plug-in screw terminals) Fast Connect The terminals are indicated in the selection and ordering data by orange backgrounds. Siemens IC 10 N 1/011 /3

10 Introduction Siemens AG 01 Transmission technology Overview is an open, international standard according to EN 5095 and IEC 606- for process and field communication. Leading manufacturers of actuators and sensors all over the world support the. Interested companies are provided with the electrical and mechanical specifications by the Association. is a single master system. For automation systems from Siemens, there are communications processors (CPs) communications modules (CMs) and routers (links) that control the process or field communication as masters, and actuators and sensors that are activated as slaves. Laptop Remote access, e.g. via teleservice PC S7 100 with CP14 7 Control and monitoring system Motion Control Systems Telecontrol and substation control Database Server IWLAN Security Notebook Access Point Access Point Field device for intrinsically safe area PC/PG/IPC Link Coupler Link PROFIBUS PA ASM456 Field devices SIMOCODE Access Point Power supply LOGO! Controller Link Power supply Module Compact feeder arrangement Sensors SINAMICS Sensors Slaves Compact starter Load feeder Slaves Signalling column Field device G_IK10_XX_000 Benefits A key feature of technology is the use of a shared two-conductor cable for data transmission and the distribution of auxiliary power to the sensors/actuators. A power supply unit which meets the requirements of the transmission method and has an external data decoupling module if required is used for the distribution of auxiliary power. The cable used for the wiring is mechanically coded and hence protected against polarity reversal and can be easily contacted by the insulation piercing method. Elaborately wired control cables in the control cabinet and marshalling racks can be replaced by. The cable can be connected to any points thanks to a specially developed cable and connection by the insulation piercing method. With this concept you become extremely flexible and achieve high savings. Application I/O data exchange The AS-i master transmits automatically the inputs and outputs between the control system and the digital and analog slaves. Slave diagnostics information is forwarded to the control system when required. masters according to the Specification V.1 or V3.0 support integrated analog value processing. This means that data exchange with analog slaves is just as easy as with digital slaves. Command interface In addition to I/O data exchange with binary and analog slaves the masters provide a number of other functions through the command interface. Hence it is possible, for example, for slave addresses to be issued, parameter values transferred or configuration information read out from user programs. You can find more information on the Internet at /4 Siemens IC 10 N 1/011

11 Introduction Communication overview Overview System components To implement the communication, a system installation has the following main components: Master interface modules for central control units such as SI- MATIC S7, ET 00 M distributed peripherals, or routers from PROFIBUS/PROFINET to Power supply units, if required in combination with a data decoupling module for the power supply to the slaves shaped cables Network components such as repeaters and extension plugs (cannot be used for AS-i Power4V) Modules for connection of standard sensors/actuators Actuators and sensors with integrated AS-i slave Safety modules for transmitting safety-oriented data through Addressing units for setting the slave addresses during commissioning SIMATIC/ SIMOTION PROFINET Industrial Ethernet power supply Analog and digital K0, K45, K60 field modules S7-300 CP343-(P) S7-100 with CM 143- Safe position switch with door interlock DP/AS-i F-Link DP/AS-i Link Advanced DP/AS-i Link 0E S7-00 mit CP43- Safe EMERGENCY-STOP and field module Signaling columns Pushbuttons Indicator lights PROFIBUS DP S7-300 CP343-(P) IE/AS-i Link PN IO power supply Safe and standard control cabinet modules S.5 and S45 4 V DC power supply 3RK3 Modular Safety System 3RK1 safety monitor 3RA load feeders 3RA6 compact starters SIRIUS M00D motor starters or G110D frequency converters Load feeders with safe AS-i outputs G_IK10_XX_007g Example of a configuration with the system components Features Standard EN 5095 / IEC 606- Topology Transmission medium Connection methods Maximum cable length Line, star or tree structure (same as electrical wiring) Unshielded two-conductor cable ( x 1.5 mm or x 1.5 mm ) for data and auxiliary power Contacting of the cable by insulation piercing method 100 m without repeater 00 m with extension plug 300 m with two repeaters in series connection 600 m with extension plugs and two repeaters connected in parallel Larger cable lengths are also possible when additional repeaters are connected in parallel Maximum cycle time Number of stations per line Number of binary sensors and actuators Access control Error safeguard 5 ms in full expansion with standard addresses 10 ms in full expansion with A/B addresses, profile-specific for Spec 3.0 slaves 31 slaves acc. to Spec. V.0 6 slaves (A/B technology) acc. to Spec. V.1 and V3.0 Integrated analog value transmission Max. 14 DI/14 DO according to Spec. V.0; Max. 48 DI/186 DO according to Spec. V.1 Max. 496 DI/496 DO according to Spec. V3.0 Cyclic polling master/slave procedure Cyclic data acceptance from host (PLC, PC) Identification and repetition of faulty message frames Siemens IC 10 N 1/011 /5

12 Introduction specification Specification.0,.1 and 3.0 Siemens AG 01 Overview Scope of the specification specification Maximum number of slaves Number of digital inputs Number of digital outputs Digital Analog ASIsafe DI DO Version = = 14 Version = = 186 Version = = 496 Basic data of Specification.0 Specification.0 describes a fieldbus system with an AS-i master and up to 31 AS-i slaves. Each AS-i slave has up to 4 digital inputs and 4 digital outputs. With full expansion, the complete transmission of all input/output data requires max. 5 ms cycle time. Expansions of Specification.1 Specification.1 enables the number of network stations to be doubled from 31 to 6 as follows: The standard slaves continue to occupy one AS-i address (1...31). Slaves with extended addressing divide an address into an A address (1A...31A) and a B address (1B...31B). Up to 6 A/B slaves can be connected accordingly to one AS-i network. Mixed operation of standard slaves and A/B slaves is possible without difficulty. The AS-i master identifies automatically which type of slave is connected. No special adjustments are required of the user. Another function of the Specification V.1 is the integrated analog value transmission function. Access to both analog values and digital values is possible without the need for any special function blocks. Expansions of Specification 3.0 Specification 3.0 enables the connection of a nearly 1000 digital inputs/outputs (profile S-7.A.A: 8DI/8DO as A/B slave). New profiles have also enabled the option of expanded addressing for analog slaves. Acceleration of analog value transmission through "Fast Analog Profile". Variable use of analog modules: Optional parameterization of resolution (1/14 bit) and 1 and -channel capability. Asynchronous serial protocol 100 baud or 50 baud, bidirectional. masters To be able to operate A/B slaves on an network you must use master modules that meet the minimum requirements of Specification.1. The AS-i masters for S7-300 / ET 00M and S7-100 as well all DP/AS-i links and IE/AS-i links comply with Specification 3.0 and support all new and previous slaves. specification Available masters Version.1 CP 43- (S7-00) Version 3.0 CP 343-, 343-P (S7-300 / ET 00M), DP/AS-i Link Advanced, DP/AS-i F-Link, DP/ Link 0E, IE/AS-i Link PN IO, CM 143- The specification relevant for the respective slave For the exact slave profile see system manual. is noted in the Selection and ordering data. Communication cycle specification Version.0 Version.1 Version 3.0 Each address is queried in max. 5 ms cycle time. If two A/B slaves are operated on one basic address (e. g. 1A and 1B), a maximum 10 ms will be required for updating the data of both slaves. More information Maximum cycle time (digital signals) 5 ms 5 ms with 31 slaves 10 ms with 6 slaves 5 ms with 31 slaves 10 ms with 6 slaves, supplementary, up to 0 ms with A/B slaves using 4DI/4DO, up to 40 ms with A/B slaves using 8DI/8DO. Whether an slave is a standard slave or an A/B slave can be seen in the section "Selection and ordering data" or the system manual. All slave types can be mixed and used on a single network. system manual More information is available in the system manual. The German and English-language System Manual can be downloaded free from the Internet, see The system manual is also available in print under the following order number. German 3RK 703-3AB0-1AA1 English 3RK 703-3BB0-1AA1 Internet More information is available on the Internet, see the opening information in IC on page16. /6 Siemens IC 10 N 1/011

13 Introduction specification AS-i Power4V expansion Overview Benefits AS-i Power4V networks incur no additional costs for an power supply unit because an already existing 4 V power supply unit can be used. This brings the user several benefits: The level of standardization of very small applications can be increased further. The additional advantages of a modern communication system in terms of commissioning, maintenance and diagnostics can be fully exploited. Application Construction of an AS-i Power4V network data decoupling modules for AS-i Power4V, left: S.5 data decoupling module, right: DCM 171 data decoupling module for SIMATIC S7-100 Parallel wiring often dominates still, particularly in applications with very few I/Os. Although is similarly well suited for small applications, its use is often prevented by the cost of the 30 V power supply unit which is required in addition. Through the expansion of with AS-i Power4V and the resulting possibility of using existing standard 4 V DC power supply units in AS-i networks, is now also attractive for applications with a very tight budget. Data and power in standard networks up to now One of the great advantages of is the ability to convey not only data but also the power needed for the connected slaves and sensors over the same unshielded two-conductor cable. This is owed to the service-proven power supply units which provide integrated data decoupling as well as overload and short-circuit protection and integrated ground fault monitoring. The new technology Through the expansion of with AS-i Power4V it is now also possible to use 4 V standard power supply units in AS-i networks. The communication technology of works at the same high level of quality with an operating voltage of both 30 V DC and 4 V DC. Key data of AS-i Power4V Number of slaves Up to 6 standard slaves and up to 31 safe slaves Topology Any Range Up to 50 m Components 4V power supply unit with little residual ripple AS-i Power4V-capable data decoupling with integrated ground-fault detection AS-i Power4V-capable masters, slaves and components Requirements for operation of an AS-i Power4V network The maximum range of 50 m must be observed in order to reach slaves and sensors with a sufficient level of voltage (at least 0 V). The power supply units must comply with the PELV Standard (Protective Extra Low Voltage) and have a residual ripple of < 50 mvpp. We recommend power supply units from the SI- TOP range, see chapter 15 in IC When used in conjunction with standard 4 V power supply units, each AS-i network requires Power4V-capable data decoupling with adapted ground fault detection. For reliable operation of an AS-i network with 4 V voltage it is important that the masters, slaves and other components are approved for AS-i Power4V. AS-i Power4V-capable AS-i components can also be used without restriction in standard 30 V AS-i networks. The use of repeaters or extension plugs in AS-i Power4V networks is not permitted. PROFINET Construction of an AS-i Power4V network with an DCM 171 data decoupling module and S7-100 (simple network) More information I/O modules S7-100 with DCM 171, CM 143- and 4 V standard power supply unit Up to 50 m Complete overview of AS-i Power4V-capable units currently available from Siemens see Details of AS-i Power4V see the opening information in IC on page 16. NSB0_045 Siemens IC 10 N 1/011 /7

14 Masters Masters for SIMATIC S7 CM 143- Siemens AG 01 Overview CM 143- communication module for S7-100 The CM 143- communication module is the master for the SIMATIC S7-100 and has the following features: Connection of up to 6 slaves Integrated analog value transmission (Analog Profiles 7.3 and 7.4) Supports all master functions according to the Specification V3.0 Indication of the operating state on the front of the device displayed via LED Display of operating mode, voltage faults, configuration faults and peripheral faults via LED behind the front flap Compact enclosure in the design of the SIMATIC S7-100 Suitable for AS-i power 4V: in combination with the optional DCM 171 data decoupling module, a standard 4 V power supply unit can be used Configuration and diagnostics via the TIA portal Design The CM 143- communication module is positioned to the left of the S7-100 CPU and linked to the S7-100 via lateral contacts. It has: Terminals for two AS-i cables (internally jumpered) via two screw terminals each respectively One terminal for connection to the functional ground LEDs for indication of the operating state and fault statuses of the connected slaves The screw terminals (included in delivery) can be removed to facilitate installation. Function The CM 143- supports all specified functions of the Specification V3.0. The values of the digital AS-i slaves can be activated via the process image of the S During configuration of the slaves in the TIA Portal, the values of the analog AS-i slaves can also be accessed via process image transfer. It is also possible to exchange all data of the AS-i master and the connected AS-i slaves with the S7-100 via the data record interface. Changeover of the operating mode, automatic application of the slave configuration and the re-addressing of a connected AS-i slave can be implemented via the control panel of the CM 143- in the TIA portal. The optional DCM 171 data decoupling module has an integrated recognition unit for detecting ground faults on the cable. The integrated overload protection also disconnects the cable if the drive power required exceeds 4 A. Configuration To configure CM 143-, you require STEP 7 V11+Servicepack or higher. You also require the hardware support package for the CM 143-, which can be obtained via Siemens Internet Service&Support. The software enables user-friendly configuration and diagnostics of the AS-i master and any connected slaves. Alternatively, you can also apply the ACTUAL configuration at the "touch of a button" via the control panel integrated in the TIA portal/step7. Benefits More flexibility and versatility in the use of SIMATIC S7-100 as the result of a significant increase in the number of digital and analog inputs/outputs available Very easy configuration and diagnostics of the via STEP7 V11 (TIA portal) No need for the AS-i power supply unit with AS-i Power4V: The AS Interface cable assembly is fed through an existing DC 4 V PELV power pack. The AS-i DCM 171 data decoupling module is required for decoupling, see page /16. LEDs for indication of fault statuses for fast diagnostics Monitoring of voltage facilitates diagnostics /8 Siemens IC 10 N 1/011

15 Masters Masters for SIMATIC S7 CM 143- Application The CM 143- is the master connection for the 1x CPUs of the SIMATIC S Connection to the greatly increases the number of inputs and outputs available for S7-100 (max. 496 DI / 496 DO on the per CM). The integrated analog value processing also makes the analog values available at the for the S7-100 (per CM up to 31 standard analog slaves, each with up to 4 channels, or up to 6 A/B analog slaves, each with up to channels). Selection and ordering data Version DT Order No. Price per PU PU (UNIT, SET, M) PS* PG CM 143- communication module A 3RK7 43-AA30-0XB0 1 1 unit 4C masters for SIMATIC S7-100 Corresponds to Specification V3.0; Dimensions (W H D / mm): RK7 43-AA30-0XB0 Accessories Version DT Order No. Price per PU PU (UNIT, SET, M) PS* PG 5-pole screw terminal for AS-i CM 143- master and AS-i DCM 171 data decoupling module With screw terminals } 3RK MA unit 4C More information The manuals are also available on the Internet at * You can order this quantity or a multiple thereof. Siemens IC 10 N 1/011 /9

16 Masters Masters for SIMATIC S7 CP 43- Siemens AG 01 Overview CP 43- The CP 43- is the master for the SIMATIC S7-00 and has the following features: Connection of up to 6 slaves Integrated analog value transmission (Analog Profiles 7.3 and 7.4) Supports all master functions according to the extended specification V.1 Display of the operating state and readiness for operation of connected slaves by means of LEDs in the front panel Fault indications (e. g. voltage fault, configuration fault) by means of LEDs in the front panel Compact enclosure in the design of the SIMATIC S7-00 Design The CP 43- is connected like an expansion module to the S7-00. It has: Two screw terminals for direct connection of the cable LEDs in the front panel for displaying the operating state and functional readiness of all connected slaves Two pushbuttons for displaying the status information of the slaves, for switching over the operating state and for adopting the existing ACTUAL configuration as the DESIRED configuration. Function The CP 43- supports all specified functions of the extended Specification V.1. In the process image of the S7-00 the CP 43- occupies one digital input byte (status byte), one digital output byte (control byte), and 8 analog input and 8 analog output words. The CP 43- thus occupies two (logic) slots. The operating mode of the CP 43- can be set with the status byte and the control byte using the user program. Depending on the operating mode, the CP 43- saves either the digital or analog I/O data of the slaves or diagnostic values in the analog address area of the S7-00, or it enables master calls (e. g. re-addressing of the slaves). Configuration All connected slaves are configured at the press of a button. No further configuration of the CP is required. Benefits More flexibility and versatility in the use of SIMATIC S7-00 as the result of the distinct increase in the number of digital and analog inputs/outputs available Shorter start-up times through simple configuration at the press of a button Reduction of standstill and servicing times in the event of a fault thanks to the LED indicators Status of the CP - Display of all the slaves connected and their readiness for operation - Monitoring of the mains voltage Application The CP 43- is the master connection for the x CPUs of the SIMATIC S7-00. Through connection to the number of inputs and outputs available for S7-00 is greatly increased (max. 48 DI / 186 DO on the per CP). Analog values (per CP a maximum of 31 standard analog slaves with up to 4 channels each) also become available on the AS- Interface for the S7-00 thanks to the integrated analog value processing. On the S7-00, up to two CP 43- communications processors can be operated simultaneously. Selection and ordering data Version DT Screw terminals PU (UNIT, SET, M) PS* PG Order No. Price per PU CP 43- communications processors } 6GK7 43-AX01-0XA0 1 1 unit 4C For connection of the SIMATIC S7-00 to ; corresponds to Specification V.1; dimensions (W x H x D / mm): 71 x 80 x 6 (dimensions without fixing lugs) 6GK7 43-AX01-0XA0 More information The manuals are also available on the Internet at /10 Siemens IC 10 N 1/011 * You can order this quantity or a multiple thereof.

17 Masters Masters for SIMATIC S7 CP 343-P, CP 343- Overview CP 343-P / CP 343- The CP 343-P is the master for the SIMATIC S7-300 and the ET 00M distributed I/O station, with user-friendly parameterizing options. The CP 343- is the basic version of the same module. The CP 343-P / CP 343- has the following features: Connection of up to 6 slaves Integrated analog value transmission (all analog profiles) Supports all master functions according to the Specification V3.0 Status displays of operating states and indication of the readiness for operation of connected slaves by means of LEDs in the front panel Fault indications (e. g. voltage fault, configuration fault) by means of LEDs in the front panel Compact enclosure in the design of the SIMATIC S7-300 Suitable for AS-i Power4V (product version and higher / firmware version 3.1) and standard AS-i (30 V) Extra with the CP343-P: Supports detailed configuration of the -network with STEP 7 V5. and higher Design The CP 343-P / CP 343- is connected like an I/O module to the S It has: Two terminal connections for direct connection of the cable LEDs in the front panel for displaying the operating state and the readiness for operation of all connected and activated slaves Pushbuttons for switching over the master operating state and for adopting the existing ACTUAL configuration of the AS-i slave as the DESIRED configuration Function The CP 343-P / CP 343- supports all specified functions of the extended Specification V3.0. The CP 343-P / CP 343- occupies 16 bytes each in the I/O address area of the SIMATIC S The digital I/O data of the standard slaves and A slaves are saved in this area. The digital I/O data of the B slaves and the analog I/O data can be accessed with the S7 system functions. If required, master calls can be performed with the command interface, e. g. read/write parameters, read/write configuration. You can find more information on the Internet at Configuration All connected slaves are configured at the press of a button. No further configuration of the CP is required. Additional features of the CP 343-P The CP 343-P also supports configuring of the network with STEP 7 V5. and higher. Specifying the AS-i configuration in HW-Config facilitates the setting of slave parameters and documentation of the plant. Uploading the ACTUAL configuration of an already configured network is also supported. The saved configuration cannot be overwritten at the press of a button and is therefore tamper-proof. Benefits Shorter start-up times through simple configuration at the press of a button Construction of flexible distributed structures by use in the DPslave ET 00M Provides diagnostics of the networks Well suited also for complex applications thanks to connection options for 6 slaves and integral analog value processing Reduction of standstill and servicing times in the event of a fault thanks to the LED indicators: - Status of the network - Slaves connected and their readiness for operation - Monitoring of the mains voltage Lower costs for stock keeping and spare parts because the CP can be used for the SIMATIC S7-300 as well as for the ET 00M Extra with the CP 343-P: Improved plant documentation and support for service assignments thanks to a description of the configuration in the STEP7 project No need for the AS-i power supply unit with AS-i Power4V: The cable is supplied through an existing 4 V DC PELV power supply unit. An AS-i data decoupling module (e. g. 3RK DE1-1AA0) is required for the decoupling, see page /14. Operation with power supply (see page /13) possible without restrictions. Siemens IC 10 N 1/011 /11

18 Masters Masters for SIMATIC S7 CP 343-P, CP 343- Siemens AG 01 Application The CP 343-P / CP 343- is the master connection for the SIMATIC S7-300 and the ET 00M. Through connection to it is possible to access max. 48 DI/48 DO per CP, using 6 A/B slaves with 4DI/4DO each. With the integrated analog value processing it is easy to transmit analog signals (per CP up to 6 A/B analog slaves with a maximum of two channels each or up to 31 A/B analog slaves with a maximum of 4 channels each). The CP 343-P is the further development of the CP 343- and contains its entire functionality. An existing STEP 7 user program for a CP 343- can thus be used without restrictions with a CP 343-P. It is only in STEP 7 HW-Config that the two modules are configured differently, with the CP 343-P offering additional options. This is why the CP 343-P is recommended. Selection and ordering data Version DT Order No. Price per PU PU (UNIT, SET, M) PS* PG CP 343-P communications processors } 6GK7 343-AH11-0XA0 1 1 unit 4C For connection of SIMATIC S7-300 and ET 00M to AS- Interface; configuration of the AS-i network using the SET key or STEP 7 (V5. and higher); without front connector; corresponds to Specification V3.0; dimensions (W x H x D / mm): 40 x 15 x 10 6GK7 343-AH11-0XA0 CP 343- communications processors } 6GK7 343-AH01-0XA0 1 1 unit 4C Basic version for connection of SIMATIC S7-300 and ET 00M to Configuration of the AS-i network using the SET key; without front connector; corresponds to Specification V3.0; dimensions (W x H x D / mm): 40 x 15 x 10 6GK7 343-AH01-0XA0 Accessories Version DT Order No. Price per PU PU (UNIT, SET, M) PS* PG Front connectors, 0-pole With screw terminals A 6ES7 39-1AJ00-0AA0 1 1 unit 30 With spring-type terminals A 6ES7 39-1BJ00-0AA0 1 1 unit 30 More information The manuals are also available on the Internet at Information about AS-i Function Block Library for PCS 7 for easy connection of to PCS 7 see Chapter 14 in IC Industry Mall: "Automation" "Industrial controls" "Parameterization, configuration and visualization for SIRIUS" "AS- Interface Function Block Library for SIMATIC PCS 7" /1 Siemens IC 10 N 1/011 * You can order this quantity or a multiple thereof.

19 Power Supply Units and Data Decoupling Modules power supply units Overview power supply unit for 3 A power supply units feed 30 V DC into the cable and supply the components. They include power-optimized data decoupling for the separation of communication signals and control supply voltage. As the result, is able to convey both data and power along a single line. The power supply units are resistant to overloads and short circuits. Dimensions power supply units have compact dimensions in widths of 50 / 70 / 10 mm. No distances from other devices need to be observed when mounting the power supply units. Features Higher rating: The power supply units deliver currents of.6 to 8 A. Integrated data decoupling: As the result, is able to convey both data and power along a single line. Integrated ground-fault detection: The power supply units perform the reliable detection and signaling of ground faults according to IEC The voltage can be disconnected automatically in the event of a ground fault. Integrated overload detection: An output overload is detected and reported over a diagnostics LED. Diagnostics memory: Any ground faults or overloads on the output side are stored in a diagnostics memory until the device is reset. Remote reset and remote signaling: Using relay contacts, a ground fault can be signaled and evaluated by a central controller and/or indicator light. Diagnostics LEDs: Three different LEDs indicate the status of the power supply locally at the power supply unit. Ultra-wide input range / two-phase connection: The ultra-wide input range of 10 to 500 V of the 8 A version means that the supply units can be used in virtually any network worldwide. In addition, this version dispenses with the need for an N conductor as the device can be connected directly between phases of a network. Operation with 4 V DC: The 3 A power supply unit is also available as a variant with a 4 V DC input. This power supply unit is suitable for use in battery-powered systems or in systems with UPS (uninterruptible power supply). Removable terminal blocks with spring-type connections: For easy exchanging of devices, each power supply unit has three removable terminal blocks: for the input side, for the output side and for Signal/Reset connections. Benefits Complete solution for supplying networks while making full use of the maximum possible cable length of 100 m or 00 m (with an extension plug) per AS-i Segment Only AS-i masters and AS-i slaves need to be connected to the cable in order to operate Compact, space-saving dimensions Reliable power supply even for large numbers of modules with a high power requirement Integrated ground-fault and overload detection saves the need for additional components and enhances safety Fast fault detection and reduced downtimes thanks to diagnostics memory, remote signaling and remote reset Reduced downtimes as the result of removable terminal blocks which enable the fast exchanging of devices Ultra-wide input range of the 8 A version permits single-phase and two-phase operation and saves the need for an N conductor Can be used world-wide thanks to for example UL/CSA approval (UL 508) With the.6 A version the output power is restricted to max. 100 W for use in NEC Class circuits Selection and ordering data 3RX BA00 Version DT PU (UNIT, SET, M) Order No. Price per PU power supply units, IP0 AS-i single output 30 V DC With integrated ground-fault detection With the.6 A version the output power is restricted to max. 100 W (for use in NEC Class circuits) Dimensions: Width: 50 mm (3 A /.6 A); 70 mm (5 A), 10 mm (8 A); Height: 15 mm; Depth: 15 mm Output current Input voltage Spring-type terminals.6 A / max. 100 W 10 / 30 V AC (selectable) } 3RX9 501-BA unit 4C 3 A 10 / 30 V AC (selectable) } 3RX BA unit 4C 3 A 4 V DC } 3RX BA unit 4C 5 A 10 / 30 V AC (selectable) } 3RX9 50-0BA unit 4C 8 A 10/ V AC (selectable) } 3RX BA unit 4C PS* PG 3RX BA00 * You can order this quantity or a multiple thereof. Siemens IC 10 N 1/011 /13

20 Power Supply Units and Data Decoupling Modules S.5 data decoupling modules Overview S.5 double data decoupling modules Left: screw terminal version, Right: spring-type terminal version With the aid of the S.5 data decoupling module, the network can also be supplied with 4 V DC or 30 V DC from a standard power supply unit and the transmission of data and power can be realized along one cable. The combination of data decoupling modules and standard power supply units is therefore a cost-efficient alternative to the service-proven power supply units. The quality of the data signals and the reliable operation of the AS-i network are not negatively affected as the result. Features of the S.5 data decoupling module Degree of protection IP0 Narrow design:.5 mm wide Version with screw or spring-type terminals Versions for single and double data decoupling Supply of several AS-i networks with a single power supply unit Operation with 4 V DC or 30 V DC, grounded or nongrounded Adjustable current limiting up to x 4 A Integrated ground-fault detection with fault storage Diagnostics LEDs and signaling contacts Reset by button or remote reset Application The data decoupling module is designed for networks with 30 V supply or 4 V supply ( Power4V). Operation of an AS-i network with the data decoupling module and a 30 V DC standard power supply unit is technically equivalent to the use of an power supply unit and offers the service-proven features of for all applications. Power4V uses a 4 V DC power supply unit in conjunction with a data decoupling module and is particularly suitable for Compact machines using input/output modules Applications in the control cabinet for integration of SIRIUS Innovation contactors and compact feeders (3RT contactors through 3RA7 function modules or 3RA6 compact feeders through AS-i 3RA69 add-on modules) When using the double data decoupling module or additional data decoupling modules, several networks can be operated with a single power supply unit. This results in an additional cost advantage. Note: The length of an AS-i Power4V network is restricted to 50 m in order to limit the voltage drop along the cable. AS-i masters, AS-i slaves and the sensors and actuators supplied through the AS-i cable must be designed for the reduced voltage. Sensors and actuators for the standard voltage range of 10 to 30 V can be supplied with sufficient voltage. The power supply units must comply with the PELV Standard (Protective Extra Low Voltage) and have a residual ripple of < 50 mvpp. We recommend power supply units from the SITOP range, see chapter 15 "Transformers and Power Supplies" in IC Ground-fault detection The integrated ground-fault detection works with a grounded and non-grounded supply: The connection of negative pole and ground (upstream from the data decoupling module) customary with 4 V DC power supplies is permitted. A ground fault to the negative or positive pole on the network (downstream from the data decoupling module) is detected and stored as a fault and will be signaled using LEDs and a relay contact. Benefits Compatible expansion of the system An existing standard power supply unit with 4 V DC or 30 V DC can be used for supplying AS-i networks The system can also be used in tightly budgeted applications because no power supply unit needs to be purchased Applications benefit in addition from the advantages of a modern bus system: - High level of standardization - Additional diagnostics and maintenance information - Faster commissioning Easy and cost-efficient construction of single and multiple networks is possible /14 Siemens IC 10 N 1/011

21 Power Supply Units and Data Decoupling Modules Construction of an AS-i Power4V network with an S.5 data decoupling module S.5 data decoupling modules PROFINET PROFINET S7-300 with CP 343- / CP 343-P and 4 V standard power supply unit S7-300 with CP 343- / CP 343-P and 4 V standard power supply unit Single data decoupling unit Up to 50 m Double data decoupling module Up to 50 m I/O modules NSB0_0191a I/O modules NSB0_019a I/O modules Construction of an AS-i Power4V network with an S.5 data decoupling module: Left: single network, Right: multiple network Selection and ordering data Version DT Order No. Price per PU PU (UNIT, SET, M) PS* PG S.5 data decoupling modules Screw terminals With screw terminals, removable terminals, width.5 mm, height 101 mm, depth 115 mm Single data decoupling module, 1 x 4 A } 3RK DE1-1AA0 1 1 unit 4C Double data decoupling module, x 4 A } 3RK DE-1AA0 1 1 unit 4C 3RK DE1-1AA0 S.5 data decoupling modules Spring-type terminals With spring-type terminals, removable terminals, width.5 mm, height 105 mm, depth 115 mm Single data decoupling module, 1 x 4 A } 3RK DG1-1AA0 1 1 unit 4C Double data decoupling module, x 4 A } 3RK DG-1AA0 1 1 unit 4C 3RK DG1-1AA0 Circuit diagrams Single data decoupling module Double data decoupling module * You can order this quantity or a multiple thereof. Siemens IC 10 N 1/011 /15

22 Power Supply Units and Data Decoupling Modules Data decoupling modules for S7-100 DCM 171 data decoupling module Overview Application The data decoupling module is designed for networks with 30 V supply or 4 V supply ( Power4V). Operation of an AS-i network with the data decoupling module and a 30 V DC standard power supply unit is technically equivalent to the use of an power supply unit and offers the service-proven features of for all applications. Power4V uses a 4 V DC power supply unit in conjunction with a data decoupling module and is particularly suitable for Compact machines using AS Interface input/output modules Applications in the control cabinet for integration of SIRIUS Innovation contactors and compact feeders (3RT contactors through 3RA7 function modules or 3RA6 compact feeders through AS-i 3RA69 add-on modules) DCM 171 data decoupling module for SIMATIC S7-100 Using the DCM 171 data decoupling unit, the network can also be supplied with 4 V DC or 30 V DC from a standard power supply unit and the transmission of data and power can be realized along one cable. The DCM 171 data decoupling unit has the same enclosure design as the S7-100 unit and is therefore ideal for combining with the CM 143- AS-i master. Features of the DCM 171 data decoupling unit Design: S7-100, 30 mm wide, degree of protection IP 0 Detachable terminals (included in delivery) Single data decoupling Supply of several AS-i networks with a single power supply unit Operation with 4 V DC or 30 V DC, grounded or nongrounded Current limiting at 4 A Integrated ground-fault detection Diagnostic LEDs for ground faults and overloads Signaling contact for ground-fault detection Ground-fault detection The integrated ground-fault detection works with a grounded and non-grounded supply: The connection of negative pole and ground (upstream from the data decoupling module) customary with 4 V DC power supplies is permitted. A ground connection against minus or plus pole on the AS Interface network (behind the data decoupling unit) is identified and reported via LED and a contact. Note: The length of an AS-i Power4V network is restricted to 50 m in order to limit the voltage drop along the cable. AS-i masters, AS-i slaves and the sensors and actuators supplied through the AS-i cable must be designed for the reduced voltage. Sensors and actuators for the standard voltage range of 10 to 30 V can be supplied with sufficient voltage. The power supply units must comply with the PELV Standard (Protective Extra Low Voltage) and have a residual ripple of < 50 mvpp. We recommend power supply units from the SITOP range, see chapter 15 "Transformers and Power Supplies" in IC Please also continue to observe the requirements specified in the section "Extension of AS-i Power4V" for implementation of AS-i Power4V, see page /7. Structure of an AS-i Power4V network with AS Interface DCM 171 data decoupling module PROFINET S7-100 with DCM 171, CM 143- and 4 V standard power supply unit Up to 50 m Benefits An existing standard power supply unit with 4 V DC or 30 V DC can be used for supplying AS-i networks The system can also be used in tightly budgeted applications because no power supply unit needs to be purchased Applications benefit in addition from the advantages of a modern bus system: - High level of standardization - Additional diagnostics and maintenance information - Faster commissioning I/O modules NSB0_045 /16 Siemens IC 10 N 1/011

23 Power Supply Units and Data Decoupling Modules Data decoupling modules for S7-100 DCM 171 data decoupling module Selection and ordering data Version DT Order No. Price per PU PU (UNIT, SET, M) PS* PG DCM 171 data decoupling module X 3RK7 71-1AA30-0AA0 1 1 unit 4C Optional, for AS-i Power4V for use of a standard 4 V power supply unit Dimensions (W H D / mm): RK7 71-1AA30-0AA0 Accessories Version DT Order No. Price per PU PU (UNIT, SET, M) PS* PG 5-pole screw terminal for AS-i CM 143- master and AS-i DCM 171 data decoupling module With screw terminals } 3RK MA unit 4C 3-pole screw terminal for AS-i DCM 171 data decoupling module for connecting the power supply unit With screw terminals } 3RK MB unit 4C Circuit diagrams -A1 1L+ + 1M max. 4 A EFD ASI OL DCM 171 Data Decoupling Module EARTH FAULT ASI DIAG max max. 50 ma + L+ M DQ ASI+ ASI- NSB0_044 DCM 171 single data decoupling module * You can order this quantity or a multiple thereof. Siemens IC 10 N 1/011 /17

Control Circuit Components

Control Circuit Components Control Circuit Components, IO Link I/O Modules for Operation 6/2 Introduction in the Control Cabinet, IP20 6/2 Transmission technology 6/101 Introduction 6/3 Configuration examples 6/102 SlimLine 6/4

More information

Industrial Communication

Industrial Communication Siemens AG 01 Industrial Communication Price groups 5K1, 5K, 5N3, 41B, 41H, 4C, 4D, 4F, 4J, 30, 50 / Introduction Introduction /11 Transmission technology /1 Communication overview specification /13 -

More information

30 V Power Supply Units for AS-Interface

30 V Power Supply Units for AS-Interface 30 V Power Supply Units for SIRIUS Catalog News IC 10 N Edition November 01 Answers for industry. Related catalogs Other information Industrial Controls IC 10 SIRIUS E86060-K1010-A101-A-7600 SITRAIN Training

More information

Siemens AG UG46 PLC. 1 Analog. 2 signal. 3UG48 monitoring relay

Siemens AG UG46 PLC. 1 Analog. 2 signal. 3UG48 monitoring relay Introduction Siemens AG 014 System components Overload and s By combining overload/ s with it is now possible to send data that has already been recorded and evaluated in the s directly to the controller.

More information

Applications & Tools. Failsafe and standard cross communication of the MSS 3RK3 via AS-Interface. SIRIUS Safety. FAQ February 2012

Applications & Tools. Failsafe and standard cross communication of the MSS 3RK3 via AS-Interface. SIRIUS Safety. FAQ February 2012 Cover sheet Failsafe and standard cross communication of the MSS 3RK3 via AS-Interface SIRIUS Safety FAQ 58512565 February 2012 Applications & Tools Answers for industry. Industry Automation und Drives

More information

Industrial Controls. AS-Interface. AS-i Master CM and AS-i Data Decoupling Unit DCM 1271 for SIMATIC S Manual. Answers for industry.

Industrial Controls. AS-Interface. AS-i Master CM and AS-i Data Decoupling Unit DCM 1271 for SIMATIC S Manual. Answers for industry. Industrial Controls AS-Interface AS-i Master CM 1243-2 and AS-i Data Decoupling Unit DCM 1271 for SIMATIC S7-1200 Manual Edition 04/2013 Answers for industry. AS-i master CM 1243-2 and AS-i data decoupling

More information

Parametrization, Configuration and Visualization with SIRIUS

Parametrization, Configuration and Visualization with SIRIUS Parametrization, Configuration and Visualization with SIRIUS Price Groups PG 1, 131, 191, 200 /2 Introduction /5 Soft Starter ES /8 SIRIUS 3RW44 soft starter block library for SIMATIC PCS 7 new /10 Motor

More information

SIMATIC S plus TIA Portal

SIMATIC S plus TIA Portal Product range overview SIMATIC S7-1500 plus TIA Portal Power + Efficiency The ultimate plus in automation Intuitive, efficient, proven TIA Portal redefines engineering Answers for industry. Your plus of

More information

For Efficiency and Reliability in the Control Cabinet. The SIRIUS 3RA6 Compact Starter SIRIUS. Answers for industry.

For Efficiency and Reliability in the Control Cabinet. The SIRIUS 3RA6 Compact Starter SIRIUS. Answers for industry. For Efficiency and Reliability in the Control Cabinet The SIRIUS 3RA6 Compact Starter SIRIUS Answers for industry. Highlights Space savings in the control cabinet, thanks to compact design Minimized engineering,

More information

AS-Interface, IO Link, Specialized Motor Starters

AS-Interface, IO Link, Specialized Motor Starters , IO Link, Specialized Motor Starters Industrial Controls Product Catalog 2019 Section contents /2 Siemens complete offering is found on our website www.siemens.ca/industrialcontrols IO-Link /12 Siemens

More information

Industrial Controls. Safety Integrated Application Manual. ASIsafe circuits for safety technology with AS-Interface safety monitor and DP/AS-i F-Link

Industrial Controls. Safety Integrated Application Manual. ASIsafe circuits for safety technology with AS-Interface safety monitor and DP/AS-i F-Link Safety Integrated Application Manual ASIsafe circuits for safety technology with AS-Interface safety monitor and DP/AS-i F-Link Function Manual 08/2012 Industrial Controls Answers for industry. ASIsafe

More information

Power Supplies & Logic Modules

Power Supplies & Logic Modules Power Supplies & Logic Modules Industrial Controls Product Catalog 2017 Section contents Introduction /2 SITOP Selection Tool /3 Selection tables for power supplies /4 /5 SITOP compact Introduction /6

More information

Power Management System. Measuring Devices for Power Distribution

Power Management System. Measuring Devices for Power Distribution Power Management System Measuring Devices for Power Distribution Power Management System System overview /2 - Overview /2 - More information SENTRON Power Monitoring Devices General data /3 - Overview

More information

SITRAIN. Introduction TIA Portal. Siemens AG All rights reserved. Unrestricted

SITRAIN. Introduction TIA Portal. Siemens AG All rights reserved. Unrestricted Introduction TIA Portal Unrestricted Siemens AG 2011. All rights reserved. Orange juice factory TIA-PRO1 / Introduction TIA Portal Page 2 Siemens AG 2011 HMI System HMI and SCADA TIA-PRO1 / Introduction

More information

Power Management System. Multifunction Measuring Instruments

Power Management System. Multifunction Measuring Instruments Power Management System Multifunction Measuring Instruments Power Management System /2 - System overview /2 - More information PAC3200 Multifunction Measuring Instruments /3 - Overview /4 - Benefits /5

More information

Combinable for All Applications

Combinable for All Applications Combinable for All Applications 3SE5 Position Switches www.siemens.com/sirius-detecting The Clever Answer to Information Diversity in the Field The Comprehensive Range of Position Switches 3SE5 position

More information

SIRIUS Overload Relays. SIRIUS 3RB24 Solid-State Overload Relays with Complete Starter Functionality via IO-Link

SIRIUS Overload Relays. SIRIUS 3RB24 Solid-State Overload Relays with Complete Starter Functionality via IO-Link Integrated Motor Protection for High-Feature Applications SIRIUS 3RB24 Solid-State Overload Relays with Complete Starter Functionality via IO-Link SIRIUS Overload Relays www.siemens.com/sirius SIRIUS 3RB24

More information

SIEMENS AG For Efficiency and Reliability in the Control Cabinet. The SIRIUS 3RA6 Compact Starter SIRIUS. Answers for industry.

SIEMENS AG For Efficiency and Reliability in the Control Cabinet. The SIRIUS 3RA6 Compact Starter SIRIUS. Answers for industry. For Efficiency and Reliability in the Control Cabinet The SIRIUS 3RA6 Compact Starter SIRIUS Answers for industry. Highlights Space savings in the control cabinet, thanks to compact design Minimized engineering,

More information

SIGUARD Safety Combinations and Safe Load Feeders. safety INTEGRATED

SIGUARD Safety Combinations and Safe Load Feeders. safety INTEGRATED SIGUARD Safety Combinations and Safe Load Feeders safety INTEGRATED EMERGENCY Topmost priority protection of man, machine and the environment The topmost priority is to protect man, machine and the environment

More information

Systems. 2/2 Introduction

Systems. 2/2 Introduction Systems Siemens AG 009 / Introduction Introduction /9 Transmission technology /10 Configuration examples /11 Communication overview /1 specification ASIsafe /14 Introduction /15 safety monitors /18 safety

More information

MICROMASTER 410/420/430/440 Inverters 0.12 kw to 250 kw Changes to the catalog DA /2006

MICROMASTER 410/420/430/440 Inverters 0.12 kw to 250 kw Changes to the catalog DA /2006 s MICROMASTER 410/420/430/440 Inverters 0.12 kw to 250 kw Changes to the catalog DA51.2 2005/2006 Please consider the following changes within the english catalog (Order No. E86060-K5151-A121-A5-7600):

More information

Integrated Control Panels Utnytt dine digitale muligheter Basic Automation TIA Portal. Siemens AG 2017

Integrated Control Panels Utnytt dine digitale muligheter Basic Automation TIA Portal. Siemens AG 2017 Integrated Control Panels Utnytt dine digitale muligheter Basic Automation TIA Portal Siemens AG 2017 www.siemens.com/panelbuilding Example of a network topology Actuators & Sensors in TIA Portal S7 1500

More information

AS-Interface. Safety Integrated Application Manual

AS-Interface. Safety Integrated Application Manual Safety Integrated Application Manual ASIsafe circuits for safety technology with AS-Interface safety monitor and DP/AS-i F-Link Function Manual 05/2009 AS-Interface Answers for industry. About this documentation

More information

Routers. DP/AS-i F-Link 2/41. Overview

Routers. DP/AS-i F-Link 2/41. Overview Siemens AG 014 Routers DP/AS-i F-Link DP/AS-i F-Link The DP/AS-i F-Link is a compact, safety-related router between PROFIBUS (DP Slave) and, with the following features: Monitoring the inputs of safety-related

More information

SIRIUS 3RB24 Solid-State Overload Relays with Complete Starter Functionality via IO-Link

SIRIUS 3RB24 Solid-State Overload Relays with Complete Starter Functionality via IO-Link SIRIUS 3RB24 Solid-State Overload Relays with Complete Starter Functionality via IO-Link Integrated Motor Protection for High-Feature Applications siemens.com/sirius Answers for industry. SIRIUS 3RB24

More information

SIMATIC S Central processing units

SIMATIC S Central processing units SIMATIC S7-1500 Siemens AG 2013 Overview CPU 1511-1 PN PROFINET IO Controller for operating distributed I/O on PROFINET PROFINET I-Device for connecting the CPU as an intelligent PROFINET device under

More information

Solid-State Contactors

Solid-State Contactors Solid-state contactors for switching motors The solid-state contactors for switching motors are intended for frequently switching on and off three-phase current operating mechanisms up to 7.5 kw and reversing

More information

The innovative interface for the last few meters to the process

The innovative interface for the last few meters to the process Industrial Communication The innovative interface for the last few meters to the process IO-Link: optimal integration of sensors and actuators siemens.com/io-link Complete communication down to the last

More information

Laboratory automation

Laboratory automation Siemens AG 2008 Laboratory automation /2 SIMATIC PCS 7 LAB: Compact control system for the laboratory automation Siemens ST PCS 7.1 Update October 2008 Laboratory automation Siemens AG 2008 Overview PCS

More information

Applications & Tools. Safe switching of the motor starters 3RM10 and 3RM12. SIRIUS Safety. FAQ February Answers for industry.

Applications & Tools. Safe switching of the motor starters 3RM10 and 3RM12. SIRIUS Safety. FAQ February Answers for industry. Cover sheet Safe switching of the motor starters 3RM10 and 3RM12 SIRIUS Safety FAQ 67478946 February 2013 Applications & Tools Answers for industry. Industry Automation and Drives Technologies Service

More information

Partner conference The digital revolution

Partner conference The digital revolution Partner conference 2018 The digital revolution www.siemens.be SIRIUS 3RW5 Soft Starters As versatile as your application Unrestricted Siemens AG 2017 siemens.com/softstarter3rw5 SIRIUS 3RW5 Soft Starters

More information

Easy, efficient and always up to date the SIRIUS modular system

Easy, efficient and always up to date the SIRIUS modular system Easy, efficient and always up to date the SIRIUS modular system siemens.com/sirius Easy, efficient and always up to date, that s how industrial controls can be! Switching Protecting Starting Monitoring

More information

SIRIUS Motor Management and Control Devices

SIRIUS Motor Management and Control Devices Overview is a flexible, modular motor management system for motors with constant speeds in the low-voltage performance range. It optimizes the connection between the control system and motor starter, increases

More information

Solid-State Switching Devices

Solid-State Switching Devices Overview 3RF21 3RF20 3RF22 3RF23 SIRIUS 3RF2 solid-state switching devices Solid-state switching devices for resistive loads Solid-state relays Solid-state contactors Function modules Solid-state switching

More information

Product Information Mixed. Configuration ET 200SP / ET 200AL SIMATIC. ET 200SP Product Information Mixed Configuration ET 200SP / ET 200AL.

Product Information Mixed. Configuration ET 200SP / ET 200AL SIMATIC. ET 200SP Product Information Mixed Configuration ET 200SP / ET 200AL. Product Information Mixed Configuration ET 200SP / ET 200AL SIMATIC ET 200SP Product Information Mixed Configuration ET 200SP / ET 200AL Product Information Preface Application planning 1 Mounting 2 Connection

More information

Revolutionizing control wiring

Revolutionizing control wiring SmartWire-DT Panel Wiring Solutions Revolutionizing control wiring 797-6925 Fax: (215) 221-1201 www.royalelectric.com SmartWire-DT Changing the way panels are wired. Reduce cost throughout the value chain.

More information

Siemens AG RA6 Fuseless Compact Starters. Catalog News LV 1 N April 2008 SIRIUS.

Siemens AG RA6 Fuseless Compact Starters. Catalog News LV 1 N April 2008 SIRIUS. 3RA Fuseless Compact Starters Catalog News LV 1 N April 2008 SIRIUS www.siemens.com/lowvoltage 3RA Fuseless Compact Starters General data Overview 3RA fuseless compact starters and infeed system for 3RA

More information

Monitoring Relays. SIRIUS 3UG Monitoring Relays for Stand-Alone Installation. Line monitoring. 8/62 Siemens IC Overview

Monitoring Relays. SIRIUS 3UG Monitoring Relays for Stand-Alone Installation. Line monitoring. 8/62 Siemens IC Overview Siemens AG 2010 Overview Benefits Can be used without auxiliary voltage in any network from 160 to 600 V AC worldwide thanks to wide voltage range Variably adjustable to overvoltage, undervoltage or range

More information

Safe shutdown of SIRIUS 3RA6 compact starters with IO-Link interface. SIRIUS Industrial Controls, Safety Integrated, IO-Link FAQ 05.

Safe shutdown of SIRIUS 3RA6 compact starters with IO-Link interface. SIRIUS Industrial Controls, Safety Integrated, IO-Link FAQ 05. FAQ 05.2016 Safe shutdown of SIRIUS 3RA6 compact starters with IO-Link interface SIRIUS Industrial Controls, Safety Integrated, IO-Link http://support.automation.siemens.com/ww/view/en/66005100 Siemens

More information

Supplementary Components WirelessHART products

Supplementary Components WirelessHART products Overview Application The connects wireless HART field devices by radio to the Ethernet. On the radio side, the supports the WirelessHART standard and on the Ethernet side the TCP/IP and Modbus TCP communication.

More information

7KT/7KM PAC Measuring Devices

7KT/7KM PAC Measuring Devices s SENTRON 7KT/ A device to suit every requirement Fully informed at all times thanks to intelligent measuring technology The 7KT/7KM PAC measuring devices ensure precise and reliable measurement of power

More information

Industrial Controls. Motor management and control devices SIMOCODE pro - Application examples. Introduction 1. Application example

Industrial Controls. Motor management and control devices SIMOCODE pro - Application examples. Introduction 1. Application example Introduction 1 Application example 2 Industrial Controls Motor management and control devices SIMOCODE pro - Application examples Application Manual Example circuits control functions 3 Further application

More information

ET 200S distributed I/O Digital electronic module 2DO AC V (6ES7132-4FB01-0AB0)

ET 200S distributed I/O Digital electronic module 2DO AC V (6ES7132-4FB01-0AB0) SIMATIC ET 200S distributed I/O SIMATIC Preface ET 200S distributed I/O Digital electronic module 2DO AC24..230V (6ES7132-4FB01-0AB0) Properties 1 Parameters 2 Diagnostics 3 Manual 04/2007 A5E01077264-01

More information

Load Feeders, Motor Starters and Soft Starters

Load Feeders, Motor Starters and Soft Starters Load Feeders, Motor Starters and Soft Starters Catalog Technical Information 3RA Fuseless Compact Starters /2 General data /2 - Overview /3 - Benefits 3RA1, 3RA2 Compact Starters /4 3RA1 direct-on-line

More information

SIRIUS Modular System

SIRIUS Modular System SIRIUS Modular System Highly flexible system-based switching, protecting and starting siemens.com/sirius Answers for industry. Everything for the electrical cabinet: SIRIUS Modular System. Contents SIRIUS

More information

Digital output module. DQ 16x24VDC/0.5A BA (6ES7522-1BH10-0AA0) SIMATIC

Digital output module. DQ 16x24VDC/0.5A BA (6ES7522-1BH10-0AA0) SIMATIC Digital output module DQ 16x24VDC/0.5A BA (6ES7522-1BH10-0AA0) SIMATIC S7-1500/ET 200MP Digital output module DQ 16x24VDC/0.5A BA (6ES7522-1BH10-0AA0) Manual Preface Documentation guide 1 Product overview

More information

SIMATIC ET 200SP and ET 200MP

SIMATIC ET 200SP and ET 200MP Engineered with TIA Portal siemens.com/et200 SIMATIC ET 200SP and ET 200MP Simple to use, smaller in size, stronger in performance Intuitive, efficient, proven TIA Portal redefines engineering Answers

More information

Siemens AG Introduction

Siemens AG Introduction Introduction Siemens AG 207 /2 /2 Introduction /3 The product range at a glance /4 SITOP Selection Tool /6 Selection tables for power supplies /8 Customized SITOP products Siemens KT 0. 207/208 Introduction

More information

Power module PM-E DC24V/8A RO SIMATIC. ET 200S distributed I/O Power module PM-E DC24V/8A RO (6ES7138-4CA80-0AB0) Preface. Properties.

Power module PM-E DC24V/8A RO SIMATIC. ET 200S distributed I/O Power module PM-E DC24V/8A RO (6ES7138-4CA80-0AB0) Preface. Properties. Power module PM-E DC24V/8A RO (6ES7138-4CA80-0AB0) SIMATIC ET 200S distributed I/O Power module PM-E DC24V/8A RO (6ES7138-4CA80-0AB0) Preface Properties 1 Parameters 2 Diagnostics 3 Configuring 4 Manual

More information

Safety is a SIRIUS business

Safety is a SIRIUS business SIRIUS 3SK Safety Relays Safety is a SIRIUS business Safety Relays for compact safety applications usa.siemens.com/safety-relays Safety is a SIRIUS business Machines can be dangerous. Personnel need to

More information

Industrial Controls. Motor management and control devices SIMOCODE pro. Introduction 1. Configuring a reversing starter. List of abbreviations

Industrial Controls. Motor management and control devices SIMOCODE pro. Introduction 1. Configuring a reversing starter. List of abbreviations Introduction 1 Configuring a reversing starter 2 Industrial Controls A List of abbreviations Motor management and control devices Getting Started 05/2018 A5E40507294002A/RS-AB/002 Legal information Warning

More information

MSI Safety Devices PRODUCT INFORMATION

MSI Safety Devices PRODUCT INFORMATION MSI Safety Devices PRODUCT INFORMATION A top system from the relay to the controller. MSI safety devices from Leuze electronic. With the MSI safety relays and safety controllers, optoelectronic safety

More information

SIMATIC ET 200SP Product information on documentation of the ET 200SP distributed I/O system Product Information

SIMATIC ET 200SP Product information on documentation of the ET 200SP distributed I/O system Product Information SIMATIC ET 200SP Product information on documentation of the ET 200SP distributed I/O system Product Information General amendments to the documentation Contents This product information includes amendments

More information

SIMATIC. ET 200S distributed I/O Power module PM-E DC24..48V (6ES7138-4CA50-0AB0) Preface. Properties 1. Parameters 2. Diagnostics 3.

SIMATIC. ET 200S distributed I/O Power module PM-E DC24..48V (6ES7138-4CA50-0AB0) Preface. Properties 1. Parameters 2. Diagnostics 3. SIMATIC ET 200S distributed I/O SIMATIC ET 200S distributed I/O Power module PM-E DC24..48V (6ES7138-4CA50-0AB0) Preface Properties 1 Parameters 2 Diagnostics 3 Configuring 4 Manual 04/2007 A5E01119980-01

More information

SITOP power supply. Selectivity modules. Overview. Safety notes. Description, device design, dimension drawing. Mounting/removal 3

SITOP power supply. Selectivity modules. Overview. Safety notes. Description, device design, dimension drawing. Mounting/removal 3 Overview Safety notes 1 SITOP power supply Manual Description, device design, dimension drawing 2 Mounting/removal 3 Mounting position, mounting clearances 4 Installation 5 Technical data 6 Safety, approvals,

More information

SIMOTION P PC-based SIMOTION P350-3

SIMOTION P PC-based SIMOTION P350-3 is a PC-based Motion Control system. In comparison to the previous version, the performance has been doubled. It is now possible to control machines with more than 40 axes in cycles of 2 ms. The operating

More information

Overvoltage Protection Devices

Overvoltage Protection Devices Siemens AG 201 /2 Introduction /3 5SD7 lightning arresters, type 1 /5 5SD7 combination surge arresters, type 1 + type 2 /7 5SD7 combination surge arresters, type 1 / type 2 /9 5SD7 surge arresters, type

More information

3RM1 Hybrid Starters 6SIRIUS. contents. Industrial Controls Product Catalog 2017

3RM1 Hybrid Starters 6SIRIUS. contents. Industrial Controls Product Catalog 2017 3RM1 Hybrid Starters Industrial Controls Product Catalog 2017 Section contents 3RM1 Compact - Hybrid Starters Overview /2 General Data /3 Selection and ordering data /4 Accessories /5 - /9 Technical Data

More information

DANGER indicates that death or severe personal injury will result if proper precautions are not taken.

DANGER indicates that death or severe personal injury will result if proper precautions are not taken. SIMATIC ET 200S distributed I/O SIMATIC ET 200S distributed I/O Digital electronic module 4DI DC24V HF (6ES7131-4BD01-0AB0) Manual Preface Properties 1 Parameters 2 Diagnostics 3 04/2007 A5E01077141-01

More information

Short Description. Version

Short Description. Version S7-400 S7-400 CP 443-1 6GK7 443-1EX11-0XE0 V2.6 S7 CP for Industrial Ethernet ISO and TCP/IP with SEND/RECEIVE and FETCH/WRITE interface, long data, UDP, TCP, ISO, S7 communication, routing, module replacement

More information

Siemens Drives & PLCs

Siemens Drives & PLCs Automation System S7-300: Getting Started CPU 31xC: Commissioning Introduction 1 Preparation 2 SIMATIC S7-300 Automation System S7-300: Getting Started CPU 31xC: Commissioning Learning units 3 Further

More information

SITOP in the SIMATIC Design

SITOP in the SIMATIC Design Siemens AG 2017 /2 Introduction /3 1-phase, 24 V DC (for S7-300 and ET 200M) /9 1-phase, 24 V DC (for S7-1200) /11 1-phase, 24 V DC (for S7-1500 and ET 200MP) /14 3-phase, 24 V DC (ET 200pro) Siemens KT

More information

Miniature Circuit Breakers for Railway Applications

Miniature Circuit Breakers for Railway Applications Siemens AG 00 for Railway Applications BETA Low-Voltage Circuit Protection The miniature circuit breakers are used in fixed railway systems and rolling stock for protecting system components against overcurrent

More information

Product Overview. by Bihl+Wiedemann

Product Overview. by Bihl+Wiedemann Product Overview by Bihl+Wiedemann About Bihl+Wiedemann Bihl+Wiedemann GmbH, founded in 1992 by Jochen Bihl and Bernhard Wiedemann, is a highly specialized, internationally operating engineering company

More information

ST (6ES7132-6FD00-0BB1)

ST (6ES7132-6FD00-0BB1) SIMATIC ET 200SP Digital output module DQ 4x24..230VAC/2A ST (6ES7132-6FD00-0BB1) Manual Edition 02/2014 Answers for industry. DQ 4x24..230VAC/2A ST Preface Guide to documentation 1 SIMATIC ET 200SP DQ

More information

Solid-State Switching Devices

Solid-State Switching Devices Controls Solid-State Switching Devices /2 Introduction Solid-State Switching Devices /3 General data Solid-State Switching Devices for Resistive Loads /5 General data Solid-State Relays /7 General data

More information

sirius Switching. Protecting. Starting. SIRIUS Product Overview

sirius Switching. Protecting. Starting. SIRIUS Product Overview sirius Switching. Protecting. Starting. SIRIUS Product Overview S00 Design Direct-on-line starting Reversing duty Assembly kit for busbar mounting 0 mm: RA9 -C 0 mm: RA9 -D Consisting of: wiring kit busbar

More information

SIMATIC. ET 200S distributed I/O Power module PM-E DC24..48V/AC V (6ES7138-4CB11-0AB0) Preface. Properties 1. Parameters 2.

SIMATIC. ET 200S distributed I/O Power module PM-E DC24..48V/AC V (6ES7138-4CB11-0AB0) Preface. Properties 1. Parameters 2. SIMATIC ET 200S distributed I/O SIMATIC ET 200S distributed I/O Power module PM-E DC24..48V/AC24..230V (6ES7138-4CB11-0AB0) Manual Preface Properties 1 Parameters 2 Diagnostics 3 Configuring 4 04/2007

More information

Simple - smaller - stronger SIMATIC ET 200SP. Unrestricted / Siemens AG All Rights Reserved.

Simple - smaller - stronger SIMATIC ET 200SP. Unrestricted / Siemens AG All Rights Reserved. Simple - smaller - stronger SIMATIC ET 200SP siemens.com/answers SIMATIC ET 200SP Overview of ET 200 portfolio Control cabinet SIMATIC S7-1500 CPU S7-1500 I/O SIMATIC ET 200PRO IP67 modular SIMATIC ET

More information

3RA13, 3RA14 Contactor Assemblies

3RA13, 3RA14 Contactor Assemblies RA1, RA Contactor Assemblies RA1 complete units,... kw Overview The RA1 reversing contactor assemblies can be ordered as follows: Sizes S00 to S Fully wired and tested, with mechanical and electrical interlock

More information

DANGER indicates that death or severe personal injury will result if proper precautions are not taken.

DANGER indicates that death or severe personal injury will result if proper precautions are not taken. Preface SIMATIC ET 200S distributed I/O Digital electronic module 2RO NO/NC DC24..48V/5A AC24..230V/5A (6ES7132-4HB50-0AB0) SIMATIC ET 200S distributed I/O Digital electronic module 2RO NO/NC DC24..48V/5A

More information

Protection Equipment

Protection Equipment Protection Equipment Price groups 41B, 41E, 41F, 41G, 41H, 41J, 42F, 42J, 143, 401 /2 Introduction Motor starter protectors/ circuit breakers SIRIUS 3RV2 motor starter protectors up to 40 A / General data

More information

Digital input module. DI 16x24VDC 8xM12 6ES7141-5AH00-0BA0) SIMATIC. ET 200AL Digital input module DI 16x24VDC 8xM12 6ES7141-5AH00-0BA0) Preface

Digital input module. DI 16x24VDC 8xM12 6ES7141-5AH00-0BA0) SIMATIC. ET 200AL Digital input module DI 16x24VDC 8xM12 6ES7141-5AH00-0BA0) Preface Digital input module DI 16x24VDC 8xM12 6ES7141-5AH00-0BA0) SIMATIC ET 200AL Digital input module DI 16x24VDC 8xM12 6ES7141-5AH00-0BA0) Manual Preface Documentation guide 1 Product overview 2 Wiring 3 Parameters/address

More information

Configuration of an MRP ring with SIMOCODE and SIMATIC S SIMOCODE pro V PN, SIMATIC S Siemens Industry Online Support

Configuration of an MRP ring with SIMOCODE and SIMATIC S SIMOCODE pro V PN, SIMATIC S Siemens Industry Online Support Configuration of an MRP ring with SIMOCODE and SIMATIC S7-1500 SIMOCODE pro V PN, SIMATIC S7-1500 https://support.industry.siemens.com/cs/ww/en/view/109742280 Siemens Industry Online Support Siemens AG

More information

Siemens AG I IA CE CP R&D-VI 4 WERNER-VON-SIEMENS-STRASSE AMBERG, GERMANY

Siemens AG I IA CE CP R&D-VI 4 WERNER-VON-SIEMENS-STRASSE AMBERG, GERMANY Issued to: Siemens AG I IA CE CP R&D-VI 4 WERNER-VON-SIEMENS-STRASSE 48 92220 AMBERG, GERMANY This is to certify that Auxiliary Devices representative samples of 3UF70 followed by 0 or 1 followed by 0

More information

SIMATIC NET. S7-CPs for PROFIBUS. CP Extended for PROFIBUS. Manual Part B4

SIMATIC NET. S7-CPs for PROFIBUS. CP Extended for PROFIBUS. Manual Part B4 SIMATIC NET S7-CPs for PROFIBUS Manual Part B4 CP 443-5 Extended for PROFIBUS 6GK7 443-5DX04-0XE0 Version 1 or higher (Firmware Version V6.1 or higher) for SIMATIC S7-400 / S7-400H Status and fault LEDs

More information

CAN 300 PRO, Communication Module

CAN 300 PRO, Communication Module 90 Communication Modules CAN 300 PRO, Communication Module Layer 2, 11 Bit and 29 Bit (CAN 2.0 A/B) on the module DIP switch for adress + baud rate Micro Memory Card for saving a project (optional) USB

More information

Overvoltage Protection Devices

Overvoltage Protection Devices Siemens AG 2010 Overvoltage Protection Devices /2 Introduction /3 Lightning Arresters, Type 1 /5 Combination Surge Arresters, Type 1 and Type 2 /7 Surge Arresters, Type 2 /11 Surge Arresters, Type 3 /12

More information

Overvoltage Protection Devices

Overvoltage Protection Devices Siemens AG 2013 Overvoltage Protection Devices /2 Introduction /3 5SD7 lightning arresters, type 1 /5 5SD7 combination surge arresters, type 1 and type 2 /7 5SD7 surge arresters, type 2 /10 5SD7 surge

More information

Channel Digital Input Module 24 V DC High-side switching

Channel Digital Input Module 24 V DC High-side switching 0-0 -Channel Digital Input Module DC High-side switching 0-0 0-0... 9 0 connection 9 9 0 0 0nF 0nF The digital input module provides channels at a width of just mm (0.in). It receives binary control signals

More information

Industrial Controls. SIMOCODE pro SIMOCODE pro PCS 7 Library. Preface. Security information. Product specific security. information.

Industrial Controls. SIMOCODE pro SIMOCODE pro PCS 7 Library. Preface. Security information. Product specific security. information. Industrial Controls SIMOCODE pro Preface 1 Product specific security Security information 2 information 3 Introduction 4 5 References 6 List of Abbreviations 7 10/2018 A5E36558134002A/RS-AB/002 Legal information

More information

SIMATIC. ET 200S distributed I/O Digital electronic module 4DO DC24V/0.5 A ST (6ES7132-4BD01-0AA0) Preface. Properties 1. Diagnostics 2.

SIMATIC. ET 200S distributed I/O Digital electronic module 4DO DC24V/0.5 A ST (6ES7132-4BD01-0AA0) Preface. Properties 1. Diagnostics 2. SIMATIC ET 200S distributed I/O Digital electronic module 4DO DC24V/0.5 A ST (6ES7132-4BD01- SIMATIC Preface Properties 1 Diagnostics 2 ET 200S distributed I/O Digital electronic module 4DO DC24V/0.5 A

More information

Industrial Controls Product Catalog RA64 / 3RA65 up to 32 A for mounting rail, surface,

Industrial Controls Product Catalog RA64 / 3RA65 up to 32 A for mounting rail, surface, Combination Starters Industrial Controls Product Catalog 2017 Section c o n t e n t s Self Protected Motor Starters per UL 508 Type E 3RA6 3RA61 / 3RA62 up to 32 A for mounting rail, surface, comb busbar,

More information

IO-Link System Description. Technology and Application

IO-Link System Description. Technology and Application IO-Link System Description Technology and Application Contents List of Figures Preface... II 1 Benefits of IO-Link.... 3 2 Systen Overwiev... 3 2.1 Overview of IO-Link................. 3 2.2 IO-Link interface...4

More information

SIMATIC. ET 200S distributed I/O 2AO U HF analog electronic module (6ES7135-4LB02-0AB0) Preface. Properties 1. Parameters 2.

SIMATIC. ET 200S distributed I/O 2AO U HF analog electronic module (6ES7135-4LB02-0AB0) Preface. Properties 1. Parameters 2. SIMATIC ET 200S distributed I/O SIMATIC ET 200S distributed I/O 2AO U HF analog electronic module (6ES7135-4LB02-0AB0) Manual Preface Properties 1 Parameters 2 Diagnostics 3 Analog value representation

More information

IO-Link System Description Technology and Application

IO-Link System Description Technology and Application www.io-link.com IO-Link System Description Technology and Application Contents Preface... 3 1 Benefits of IO-Link.... 4 2 Systen Overwiev.... 5 2.1 Overview of IO-Link...5 2.2 IO-Link interface...6 2.3

More information

SIRIUS modular system

SIRIUS modular system SIRIUS modular system Switching, protecting, starting and monitoring with the highly flexible modular system siemens.com/sirius Everything for the control cabinet: the SIRIUS modular system. Press shop

More information

ET 200S Motor Starters and Safety Motor Starters

ET 200S Motor Starters and Safety Motor Starters General data Overview ET 200S motor starters in the ET 200S I/O system The SIMATIC ET 200S is the multifunctional and finely modular I/O system in degree of protection IP20 for exact adaptation to the

More information

Siemens AG KD Switch Disconnectors SENTRON. Edition December Answers for infrastructure and cities.

Siemens AG KD Switch Disconnectors SENTRON. Edition December Answers for infrastructure and cities. KD Switch Disconnectors SENTRON Edition December 01 Answers for infrastructure and cities. Related catalogs Low-Voltage Power Distribution and LV 10 Electrical Installation Technology SENTRON SIVACON ALPHA

More information

4 COMBINATION SIRIUS. SIRIUS 3RA6 Compact Starters 4/2. General data

4 COMBINATION SIRIUS. SIRIUS 3RA6 Compact Starters 4/2. General data Combination Starters Industrial Controls Product Catalog 2019 Section contents Self Protected Motor Starters per UL 508 Type E RA6 RA61 / RA62 up to 2 A for mounting rail, surface, comb busbar, infeed

More information

154 PHOENIX CONTACT Courtesy of Power/mation Energy Lane, Saint Paul, MN

154 PHOENIX CONTACT Courtesy of Power/mation Energy Lane, Saint Paul, MN 154 PHOENIX CONTACT PROFINET The future-oriented system solution PROFINET is the realtime Ethernet approach that can be used in all industrial motion control fields - from factory automation to process

More information

AS-i 3.0 Gateways, PROFIsafe via PROFIBUS or PROFINET

AS-i 3.0 Gateways, PROFIsafe via PROFIBUS or PROFINET safe via BUS or NET AS-i 3.0 Gateways, safe via NET or BUS safe and Safe Link in one device up to 450 devices 2 / 1 Master, NET / BUS Slave AS-i Safety input slaves report via safe AS-i Safety output slaves

More information

SIMOCODE 3UF Motor Management and Control Devices

SIMOCODE 3UF Motor Management and Control Devices Technical specifications General data applicable to the basic units, current measuring modules, current/voltage measuring modules, expansion modules, decoupling module and operator panel Permissible ambient

More information

SIRIUS modular system

SIRIUS modular system SIRIUS modular system Switching, protecting, starting and monitoring with the highly flexible modular system siemens.com/sirius Everything for the control cabinet: the SIRIUS modular system. Press shop

More information

AS-i 3.0 Gateways, PROFIsafe via PROFIBUS or PROFINET

AS-i 3.0 Gateways, PROFIsafe via PROFIBUS or PROFINET safe via BUS or NET AS-i 3.0 Gateways, safe via NET or BUS safe and Safe Link in one device up to 450 devices 2 / 1 Master, NET / BUS Slave AS-i Safety input slaves report via safe AS-i Safety output slaves

More information

Drive System Application

Drive System Application Drive System Application Commissioning of the Control Unit CU230P-2 DP with PROFIBUS Application description for SINAMICS G120 and MICROMASTER 440 Warranty, liability and support Note The Application Examples

More information

SIMATIC. ET 200S distributed I/O Digital electronic module 4DO DC24V/0.5A ST (6ES7132-4BD02-0AA0) Preface. Properties 2. Diagnostics 3.

SIMATIC. ET 200S distributed I/O Digital electronic module 4DO DC24V/0.5A ST (6ES7132-4BD02-0AA0) Preface. Properties 2. Diagnostics 3. Preface 1 Properties 2 SIMATIC Diagnostics 3 ET 200S distributed I/O Digital electronic module 4DO DC24V/0.5A ST (6ES7132-4BD02- Manual 01/2008 A5E01254028-01 Safety Guidelines This manual contains notices

More information

3RT, 3TB, 3TF Contactors for Switching Motors

3RT, 3TB, 3TF Contactors for Switching Motors RT, TB, TF Contactors for Switching Motors Overview RT contactors and coupling relays Size S00 with mountable accessories The SIRIUS generation of controls is a complete, modular system family, logically

More information

L-force. Inverter Drives 8400 protec. On site and all systems go!

L-force. Inverter Drives 8400 protec. On site and all systems go! L-force Inverter Drives 8400 protec On site and all systems go! 2 L-force Decentralised drives 2 The major challenges of the future are to be found in the areas of cost efficiency, time-saving and quality

More information

Siemens Spares. Preface 1. Scope of Delivery 2 SIPLUS CMS4000. Product Characteristics 3 ION PROFIBUS DP SPY T001 Installation and Maintenance 4

Siemens Spares. Preface 1. Scope of Delivery 2 SIPLUS CMS4000. Product Characteristics 3 ION PROFIBUS DP SPY T001 Installation and Maintenance 4 Preface 1 Scope of Delivery 2 Product Characteristics 3 Industrial I/O-Node ION PROFIBUS DP SPY T001 Installation and Maintenance 4 6AT8000-1BA00-5XA0 Notes on the CE Mark 5 References 6 Appendix 7 Release

More information