DEEP SEA ELECTRONICS PLC DSE8005 SCADA Suite PC Software Manual

Size: px
Start display at page:

Download "DEEP SEA ELECTRONICS PLC DSE8005 SCADA Suite PC Software Manual"

Transcription

1 DEEP SEA ELECTRONICS PLC DSE8005 SCADA Suite PC Software Manual Document Number Author: Anthony Manton ISSUE: 8

2 DSE8005 SCADA Suite PC Software Manual DEEP SEA ELECTRONICS PLC Highfield House Hunmanby North Yorkshire YO14 0PH ENGLAND Sales Tel: +44 (0) Sales Fax: +44 (0) sales@deepseaplc.com Website : DSE SCADA Suite Software Manual Deep Sea Electronics Plc All rights reserved. No part of this publication may be reproduced in any material form (including photocopying or storing in any medium by electronic means or other) without the written permission of the copyright holder except in accordance with the provisions of the Copyright, Designs and Patents Act Applications for the copyright holder s written permission to reproduce any part of this publication should be addressed to Deep Sea Electronics Plc at the address above. The DSE logo is a UK registered trademark of Deep Sea Electronics PLC. Any reference to trademarked product names used within this publication is owned by their respective companies. Deep Sea Electronics Plc reserves the right to change the contents of this document without prior notice. Amendments List Issue Comments 1 Initial release 2 Support for 8600 V2 and 8700 V2 controllers 3 Support for display and 8680 bus tie controller 4 Support for Ethernet added. 5 Support for 73xx 5.1 Added missing File new description and more details of supported controllers 6 Support for 74xx, 86xx and 88xx 7 Added 86xx MKII & Tier IV Engine support 8 Added 73xx MKII & 74xx MKII Typeface: The typeface used in this document is Arial. Care should be taken not to mistake the upper case letter I with the numeral 1. The numeral 1 has a top serif to avoid this confusion ISSUE: 8 Page 2 of 58

3 DSE8005 SCADA Suite PC Software Manual TABLE OF CONTENTS 1 DESCRIPTION INSTALLATION INSTRUCTIONS HARDWARE INSTALLATION RS RS232 CONNECTION RECOMMENDED PC RS232 SERIAL PORT ADD-ONS RS RS485 CONNECTION RECOMMENDED PC RS485 SERIAL PORT ADD-ONS ETHERNET DIRECT PC CONNECTION CONNECTION TO BASIC ETHERNET CONNECTION TO COMPANY INFRASTRUCTURE ETHERNET CONNECTION TO THE INTERNET FIREWALL CONFIGURATION FOR INTERNET ACCESS CONFIGURING THE SCADA SUITE PROPERTIES SAVING FOR USE WITH DSE8005 SCADA SUITE PC SOFTWARE SAVING FOR USE WITH DSE OR DSE COLOUR OVERVIEW DISPLAY USING THE SCADA SUITE SYSTEM CONFIG RUNNING EDITOR AUTOSTART CONTROLLER HOME ENGINE GENERATOR BUS ALARMS I/O INPUTS OUTPUTS EXPANSION MODULES REMOTE CONTROL VIRTUAL LEDS ABOUT AUTOMATIC MAINS FAILURE CONTROLLER HOME ENGINE GENERATOR UTILITY (MAINS) ALARMS I/O INPUTS OUTPUTS EXPANSION MODULES REMOTE CONTROL VIRTUAL LEDS ABOUT MAINS CONTROLLER HOME UTILITY (MAINS) BUS ALARMS I/O INPUTS OUTPUTS EXPANSION MODULES REMOTE CONTROL VIRTUAL LEDS ABOUT BUS TIE CONTROLLER HOME BUS ALARMS I/O INPUTS OUTPUTS EXPANSION MODULES ABOUT Page 3 of ISSUE: 8

4 Installation 1 DESCRIPTION This manual covers the operation of the DSE SCADA Suite software for DSE7300 / DSE7400 / DSE8600 / DSE8600 MKII / DSE8700 / DSE 8800 series modules. Separate manuals cover the DSE modules supported by the software. The Help menu of the DSE Configuration Suite section of the software contains links to these documents, copied onto the PC during the software installation process. The DSE SCADA Suite software allows the DSE7400 / DSE8600 / 8600 MKII / DSE8700 / DSE8800 series of modules to be connected to a PC via RS232, RS485 or Ethernet for remote monitoring and control. The SCADA suite should only be used by competent, qualified personnel, as changes to the operation of the module may have safety implications on the panel / generating set to which it is fitted. Access to the settings in the controller, may be barred by a security code set by the generator provider. The information contained in this manual should be read in conjunction with the information contained in the appropriate module documentation. A separate manual deals with the operation of the individual module (See section entitled Bibliography elsewhere in this document). 2 INSTALLATION INSTRUCTIONS For information in regards to instating and using the DSE SCADA Suite Software please refer to DSE publication: DSE Configuration Suite PC Software Installation & Operation Manual which can be found on our website: ISSUE: 8 Page 4 of 58

5 Installation 3 HARDWARE INSTALLATION NOTE: An RS232 Null Modem (Cross-over) cable will be required to connect a DSE module to a PC, these can be purchased from any good PC or IT Store. 3.1 RS232 RS232 is for short distance communication (max 15m) which can be used for single controller applications to connect to a PC to a DSE controller to enable the use of the DSE SCADA Suite Software RS232 CONNECTION PIN No NOTES Received Line Signal Detector 1 (Data Carrier Detect) 2 Received Data 3 Transmit Data 4 Data Terminal Ready 5 Signal Ground 6 Data Set Ready 7 Request To Send 8 Clear To Send 9 Ring Indicator RECOMMENDED PC RS232 SERIAL PORT ADD-ONS View looking into the male connector on the DSE controller. Many PCs are not fitted with an internal RS232 serial port. DSE DOES NOT recommend the use of USB to RS232 convertors but can recommend PC add-ons to provide the computer with an RS232 port. Remember to check these parts are suitable for your PC. Consult your PC supplier for further advice. Brainboxes PM143 PCMCIA RS232 card (for laptop PCs) Brainboxes VX-001 Express Card RS232 (for laptops and nettops PCs) Brainboxes UC246 PCI RS232 card (for desktop PCs) Brainboxes PX-246 PCI Express 1 Port RS232 1 x 9 Pin (for desktop PCs) Supplier: Brainboxes Tel: +44 (0) Web: Sales: sales@brainboxes.com NB DSE Have no business tie to Brainboxes. Over many years, our own engineers have used these products and are happy to recommend them. Page 5 of ISSUE: 8

6 Installation 3.2 RS485 RS485 is used for point-to-point cable connection of more than one device (maximum 32 devices) over a large distance (max 1.2km) and allows for connection to PC to for use with the DSE SCADA Suite RS485 CONNECTION RECOMMENDED PC RS485 SERIAL PORT ADD-ONS Many PCs are not fitted with an internal RS485 serial port. DSE DO NOT recommend the use of USB to RS485 convertors but can recommend PC add-ons to provide the computer with an RS485 port. Remember to check these parts are suitable for your PC. Consult your PC supplier for further advice. Brainboxes PM154 PCMCIA RS485 card (for laptops PCs) Set to Half Duplex, Autogating with CTS True set to enabled Brainboxes VX-023 ExpressCard 1 Port RS422/485 (for laptops and nettop PCs) Brainboxes UC320 PCI Velocity RS485 card (for desktop PCs) Set to Half Duplex, Autogating with CTS True set to enabled Brainboxes PX-324 PCI Express 1 Port RS422/485 (for desktop PCs) Supplier: Brainboxes Tel: +44 (0) Web: Sales: sales@brainboxes.com NB DSE Have no business tie to Brainboxes. Over many years, our own engineers have used these products and are happy to recommend them ISSUE: 8 Page 6 of 58

7 Installation 3.3 ETHERNET The DSE7400 and DSE8000 series modules are fitted with an ETHERNET socket for connection to LAN (local area networks) Terminal Description 1 TX+ 2 TX- 3 RX+ 4 Do not connect 5 Do not connect 6 RX- 7 Do not connect 8 Do not connect Page 7 of ISSUE: 8

8 Installation DIRECT PC CONNECTION NOTE: This cable can be purchased from any good PC or IT store. Requirements DSE module with the ability to connect to Ethernet Crossover Ethernet cable (see Below) PC with Ethernet port Crossover network cable Crossover cable wiring detail Two pairs crossed, two pairs uncrossed 10baseT/100baseTX crossover Pin Connection 1 (T568A) Connection 2 (T568B) 1 white/green stripe white/orange stripe 2 green solid orange solid 3 white/orange stripe white/green stripe 4 blue solid blue solid For the advanced Engineer, a crossover cable is a CAT5 cable with one end terminated as T568A and the other end terminated as T568B. 5 white/blue stripe white/blue stripe 6 orange solid green solid 7 white/brown stripe white/brown stripe 8 brown solid brown solid ISSUE: 8 Page 8 of 58

9 Installation CONNECTION TO BASIC ETHERNET NOTE: DSE Stock a 2m (2yds) Ethernet Cable Part number Alternatively they can be purchased from any good PC or IT store. Requirements DSE module with the ability to connect to Ethernet Ethernet cable (see below) Working Ethernet (company or home network) PC with Ethernet port Ethernet cable Ethernet router or ADSL router Ethernet cable wiring detail. 10baseT/100baseT Pin Connection 1 (T568A) Connection 2 (T568A) 1 white/green stripe white/green stripe For the advanced Engineer, this cable has both ends terminated as T568A or T568B. 2 green solid green solid 3 white/orange stripe white/orange stripe 4 blue solid blue solid 5 white/blue stripe white/blue stripe 6 orange solid orange solid 7 white/brown stripe white/brown stripe 8 brown solid brown solid Page 9 of ISSUE: 8

10 Installation CONNECTION TO COMPANY INFRASTRUCTURE ETHERNET Requirements DSE module with the ability to connect to Ethernet Ethernet cable (see below) Working Ethernet (company or home network) PC with Ethernet port Ethernet router or ADSL router PC Network wall connection sockets Ethernet cable Ethernet cable wiring detail 10baseT/100baseT Pin Connection 1 (T568A) Connection 2 (T568A) 1 white/green stripe white/green stripe 2 green solid green solid 3 white/orange stripe white/orange stripe For the advanced Engineer, this cable has both ends terminated as T568A or T568B. 4 blue solid blue solid 5 white/blue stripe white/blue stripe 6 orange solid orange solid 7 white/brown stripe white/brown stripe 8 brown solid brown solid NOTE: DSE Stock a 2m (2yds) Ethernet Cable Part number Alternatively they can be purchased from any good PC or IT store ISSUE: 8 Page 10 of 58

11 Installation CONNECTION TO THE INTERNET Requirements Ethernet cable (see below) Working Ethernet (company or home network) Working Internet connection (ADSL or DSL recommended) INTERNET DSL or ADSL router Ethernet cable The DSL/ADSL router will route external network traffic. DSL or ADSL router Optional Local site PC PC remote from generator site Ethernet cable wiring detail 10baseT/100baseT Pin Connection 1 (T568A) Connection 2 (T568A) 1 white/green stripe white/green stripe 2 green solid green solid 3 white/orange stripe white/orange stripe 4 blue solid blue solid For the advanced Engineer, this cable has both ends terminated as T568A (as shown below) or T568B. 5 white/blue stripe white/blue stripe 6 orange solid orange solid 7 white/brown stripe white/brown stripe 8 brown solid brown solid NOTE: DSE Stock a 2m (2yds) Ethernet Cable Part number Alternatively they can be purchased from any good PC or IT store. Page 11 of ISSUE: 8

12 Installation FIREWALL CONFIGURATION FOR INTERNET ACCESS NOTE: Refer to the modules configuration suite manual further details on configuring As modem/routers differ enormously in their configuration, it is not possible for DSE to give a complete guide to their use with the module. However it is possible to give a description of the requirements in generic terms. For details of how to achieve the connection to your modem/router you are referred to the supplier of your modem/router equipment. The module makes its data available over Modbus TCP and as such communicates over the Ethernet using a Port configured via the DSE Configuration Suite software. You must configure your modem/router to allow inbound traffic on this port. For more information you are referred to your WAN interface device (modem/router) manufacturer. It is also important to note that if the port assigned (setting from software Modbus Port Number ) is already in use on the LAN, the module cannot be used and another port must be used. Outgoing Firewall rule As the module makes its user interface available to standard web browsers, all communication uses the chosen port. It is usual for a firewall to make the same port outgoing open for communication. Incoming traffic (virtual server) Network Address and Port Translation (NAPT) allows a single device, such as the modem/router gateway, to act as an agent between the Internet (or "public external network") and a local (or "internal private") network. This means that only a single, unique IP address is required to represent an entire group of computers. For our application, this means that the WAN IP address of the modem/router is the IP address we need to access the site from an external (internet) location. When the requests reach the modem/router, we want this passed to a virtual server for handling, in our case this is the module. Result : Traffic arriving from the WAN (internet) on port xxx is automatically sent to IP address set within the configuration software on the LAN for handling ISSUE: 8 Page 12 of 58

13 Operation Graphical Setup 4 CONFIGURING THE SCADA SUITE To run the SCADA Suite Editor Software click the Windows start button or or depending upon your version of Windows. In the Programs section of the computer s START menu, select DEEP SEA ELECTRONICS plc DSE SCADA Suite Configuration tool: This program allows the creation of a custom graphical interface for the SCADA Suite program DSE8005 or DSE8003/DSE8004 remote colour overview display module. Upon starting the software you are presented with a blank graphical file suitable for the DSE8005 SCADA Suite PC software. To change this to create a file suitable for DSE or DSE Overview Display, Select File New and select 8003/8004 Configuration: 13

14 Operation Graphical Setup To add devices to the system, drag them from the side bar to the canvas. Example of an entire system: When adding mains or generator parts to the canvas, it is not necessary to specify the controller type, this is automatically made when the SCADA suite communicates with the controllers. The software is compatible with DSE7300, DSE7300 MKII, DSE7400, DSE7400 MKII, DSE8600, DSE8600 MKII, DSE8700, and DSE8800 series controllers. DSE8620 DSE8810 / DSE8710/ DSE8610 / DSE8610 MKII Next Page DSE8760 / DSE8660 / DSE8660 MKII Alignment tools, load, save etc are provided in the modules menu bar and associated toolbar at the top of the graphical editor screen ISSUE: 8 Page 14 of 58

15 Operation Graphical Setup 4.1 PROPERTIES The properties section is used to setup the communications with the controller with a choice of RS232, RS485 or Ethernet and set the graphical properties of the display such as the controller s name (ie Gen1) and whether the symbol appears above or below the bus. Example: RS485 Configuration Example: Ethernet Configuration Bus Group allows the symbol to belong on the same generator bus as others. For example the display can show two independent generator buses, not connected. Example: BusGroup 1 Example: BusGroup 2 Page 15 of ISSUE: 8

16 Operation Graphical Setup 4.2 SAVING FOR USE WITH DSE8005 SCADA SUITE PC SOFTWARE NOTE: The file can be saved by a different naming other than DSEScadaSuite.xml, however this will not be loaded automatically when the DSE Scada Suite is started, it must be selected using the Load button in the System page of the DSE Scada Suite. Save the file to the Deep Sea Electronics PLC located in your Documents folder, with the filename:- DSEScadaSuite.xml. Example (Where Username is replaced with your Windows login name) : When SCADA Suite is started, this configuration file is automatically loaded by the software. 4.3 SAVING FOR USE WITH DSE OR DSE COLOUR OVERVIEW DISPLAY Save the file to the root of a USB pen drive with the filename:- layout.xml Insert this pen drive into the USB host socket of the DSE or DSE colour overview display. When the DSE8003 or DSE8004 display is powered up, this configuration file is automatically loaded. Operation of the DSE8003 display is covered in: DSE publication DSE8003 colour display operator manual. And the operation of the DSE8004 display is covered in: DSE publication DSE8004 colour display operator manual. USB Host Socket for configuration by USB pen drive device ISSUE: 8 Page 16 of 58

17 Operation Autostart Controller 5 USING THE SCADA SUITE To run the SCADA Suite Software program click the Windows start button or or depending upon your version of Windows. Then select All Programs - Deep Sea Electronics PLC DSE SCADA Suite After a short delay to load the application, the main display is shown. The layout of this screen is application dependant and shows a representative diagram of the system. 5.1 SYSTEM The image below shows an example with three DSE8610 s, one DSE8660 and one DSE8680 controller. This button enables the user to browse and load different SCADA configuration files. Clicking with the left mouse button in the vicinity of the generator or mains icons will change the display to show the relevant control and instrumentation page. Clicking with the right mouse button in the vicinity of the generator or mains icons will open the generator Running Editor. Clicking the CONFIG button allows configuration of the application options. The colour of the generator / mains symbols change dependant upon level of the alarm. Gen Icon Mains Icon Colour Description Grey Controller is offline (no communication) Light Blue Green Yellow Red Controller is online (communicating) in STANDBY Any mode Controller is started/active or Engine/Generator is RUNNING Any mode Controller has a WARNING alarm present Controller has a SHUTDOWN or electrical trip alarm present 17

18 Operation Autostart Controller CONFIG Clicking the CONFIG button on the System page allows configuration of the application options. This allows configuration of the display parameters and selection of the alarm sounds. If enabled, then the clocks of all attached modules will be immediately synchronised with the local PC clock and then once a day thereafter RUNNING EDITOR Clicking the mouse with the right mouse button in the vicinity of the generator or mains icons on the System page will open the generator Running Editor. Changes made with the Running Editor take place immediately and the value is changed. There is no need to save the changes. These parameters are also changed from the module fascia, DSE Config Suite SCADA section and by Modbus RTU command from a suitably configured Master device. DSE8610 / DSE8610 MKII / DSE8710 / DSE8810 DSE8620 / DSE8660 / DSE8660 MKII / DSE8760 / DSE8860 Parameter Generator Priority Select Mode Parallel Power (Min) Parallel Power (Max) Parallel Power Factor ISSUE: 8 Page 18 of 58 Description Generator Run Priority for the Load Demand scheme Select between: Bus/Gen Mode: Upon loading of the bus/generators in parallel with a mains supply, places them into fixed export. Mains Mode: Upon loading of the bus/generators in parallel with a mains supply, places them into a peak lopping/shaving application. This is the bottom of the load ramp. When the generator joins the bus, it will ramp up from this setting after closing the breaker. When the generator leaves the bus, it will ramp down to this setting before opening the breaker. The power level to be produced by the generator when in mains parallel mode (fixed export mode). The power factor to be supplied by the generator when in mains parallel mode (fixed export mode).

19 Operation Autostart Controller 5.2 AUTOSTART CONTROLLER NOTE: Depending upon module type and configuration, certain pages and values may not be displayed, the screenshots are for indication only HOME Genset Identity, Status and overview is shown at the top of every page. Genset and Site Identity are set using the DSE Config Suite Software. Control buttons to mimic the module s own fascia mounted buttons. Availability of some buttons depends upon the module type. The vertical green bar shows the module s current operating mode. Indicates the current page selected. Click the buttons to change the page. Page 19 of ISSUE: 8

20 Operation Autostart Controller ENGINE NOTE: DSE modules that support Tier 4 Final engine protocol will display additional Tier 4 warning icons & DEF level instrument support. Parameter Inactive (grey) Warning (yellow) Shutdown (red) Emission Filter Indicates that this is page 1 of 3 in this section. Press to move between the different parameters being reported from the ECU Auto Regeneration Inhibit DEF Level Low SCR Inducement Engine Air Inlet Temperature Charge alternator Oil pressure Fuel level Battery voltage Coolant temperature ECU lamp Depending upon module configuration and/or CAN ECU support, some meters may not be displayed. Water in fuel Parameter CAN link unknown (grey) CAN link active (green) CAN link lost (red) CAN link status ISSUE: 8 Page 20 of 58

21 Operation Autostart Controller GENERATOR Indicates that this is page 1 of 9 in this section. Press to move between the different pages including bargraph display: In line with normal convention: Positive (+) power factor is lagging power factor Negative (-) power factor is leading power factor Page 21 of ISSUE: 8

22 Operation Autostart Controller BUS Indicates that this is page 1 of 3 in this section. Press to move between the different pages including bargraph display: ISSUE: 8 Page 22 of 58

23 Operation Autostart Controller ALARMS Indicates that this is page 1 of 2 in this section. Press to move between the current alarms and the past event log : Alarm level Warning Electrical trip Shutdown ECU code Colour/Title graphic Page 23 of ISSUE: 8

24 Operation Autostart Controller I/O INPUTS State of the input (open or closed to battery negative) The configured input functions Shows if the input channel is active or not. This input is closed and is active. The input is configured to be close to activate Flexible Sensors when configured using the DSE Configuration Suite. Indicates that this is page 1 of 6 in this section. NOTE: Available Flexible Instruments varies from the controller connected to the DSE Scada Suite Software. Press to move between the inputs and outputs of both the module and its expansion modules: ISSUE: 8 Page 24 of 58

25 Operation Autostart Controller OUTPUTS State of the output (on/closed or off/open) Shows if the output channel is active or not. This output is closed and is active. The output is configured to be energise. The function the output is configured for Page 25 of ISSUE: 8

26 Operation Autostart Controller EXPANSION MODULES Shows the type expansion module and if communication is active or not. If multiple expansion modules of the same type are connected, press the ID number to view a different module. Shows if the expansion channel is active or not. The function the expansion device is configured for Indicates that this is page 4 of 6 in this section. Press to move between the different types expansion modules and the inputs and outputs: ISSUE: 8 Page 26 of 58

27 Operation Autostart Controller REMOTE CONTROL NOTE: Check the modules configuration before activating a remote control channel. Activating a remote control channel can change the operation of the DSE module. Shows if the remote control channel is active or not Press to turn the control on Press to turn the control off Page 27 of ISSUE: 8

28 Operation Autostart Controller VIRTUAL LEDS Shows if the virtual LED is active or not The function the virtual LED is configured for Indicates that this is page 6 of 6 in this section. Press to move between the inputs and outputs of both the module and its expansion modules: ISSUE: 8 Page 28 of 58

29 Operation Autostart Controller ABOUT Shows the PC Software and module firmware version numbers Page 29 of ISSUE: 8

30 Operation Automatic Mains Failure Controller 5.3 AUTOMATIC MAINS FAILURE CONTROLLER NOTE: Depending upon module type and configuration, certain pages and values may not be displayed, the screenshots are for indication only HOME AMF Identity, Status and overview is shown at the top of every page. AMF and Site Identity are set using the DSE Config Suite Software. Control buttons to mimic the module s own fascia mounted buttons. Availability of some buttons depends upon the module type. The vertical green bar shows the module s current operating mode. Indicates the current page selected. Click the buttons to change the page. 30

31 Operation Automatic Mains Failure Controller ENGINE NOTE: DSE modules that support Tier 4 Final engine protocol will display additional Tier 4 warning icons & DEF level instrument support. Parameter Inactive (grey) Warning (yellow) Shutdown (red) Emission Filter Auto Regeneration Inhibit Indicates that this is page 1 of 3 in this section. Press to move between the different parameters being reported from the ECU DEF Level Low SCR Inducement Engine Air Inlet Temperature Charge alternator Oil pressure Fuel level Battery voltage Coolant temperature ECU lamp Depending upon module configuration and/or CAN ECU support, some meters may not be displayed. Water in fuel Parameter CAN link status CAN link unknown (grey) CAN link active (green) CAN link lost (red) Page 31 of ISSUE: 8

32 Operation Automatic Mains Failure Controller GENERATOR Indicates that this is page 1 of 9 in this section. Press to move between the different pages including bargraph display: In line with normal convention: Positive (+) power factor is lagging power factor Negative (-) power factor is leading power factor ISSUE: 8 Page 32 of 58

33 Operation Automatic Mains Failure Controller UTILITY (MAINS) Indicates that this is page 1 of 3 in this section. Press to move between the different pages including bargraph display: Page 33 of ISSUE: 8

34 Operation Automatic Mains Failure Controller ALARMS Indicates that this is page 1 of 2 in this section. Press to move between the current alarms and the past event log : Alarm level Warning Electrical trip Shutdown ECU code Colour/Title graphic ISSUE: 8 Page 34 of 58

35 Operation Automatic Mains Failure Controller I/O NOTE: Additional I/O is available when DSE86xx MKII modules are connected, this additional I/O is displayed in the DSE8005 SCADA Suite Software INPUTS State of the input (open or closed to battery negative) Shows if the input channel is active or not. This input is closed and is active. The input is configured to be close to activate The function the input is configured for Indicates that this is page 1 of 5 in this section. Press to move between the inputs and outputs of both the module and its expansion modules: Page 35 of ISSUE: 8

36 Operation Automatic Mains Failure Controller OUTPUTS State of the output (on/closed or off/open) Shows if the output channel is active or not. This normally closed output is closed and is active. The output is configured to be de-energise. The function the output is configured for ISSUE: 8 Page 36 of 58

37 Operation Automatic Mains Failure Controller EXPANSION MODULES Shows the type expansion module and if communication is active or not. If multiple expansion modules of the same type are connected, press the ID number to view a different module. The function the expansion device is configured for Shows if the expansion channel is active or not. Indicates that this is page 3 of 5 in this section. Press to move between the different types expansion modules and the inputs and outputs: Page 37 of ISSUE: 8

38 Operation Automatic Mains Failure Controller REMOTE CONTROL NOTE: Check the modules configuration before activating a remote control channel. Activating a remote control channel can change the operation of the DSE module. Shows if the remote control channel is active or not Press to turn the control on Press to turn the control off ISSUE: 8 Page 38 of 58

39 Operation Automatic Mains Failure Controller VIRTUAL LEDS Shows if the virtual LED is active or not The function the virtual LED is configured for Indicates that this is page 5 of 5 in this section. Press to move between the inputs, outputs and expansion modules:. Page 39 of ISSUE: 8

40 Operation Automatic Mains Failure Controller ABOUT Shows the PC Software and module firmware version numbers ISSUE: 8 Page 40 of 58

41 Operation Mains Controller 5.4 MAINS CONTROLLER NOTE: Depending upon module type and configuration, certain pages and values may not be displayed, the screenshots are for indication only HOME Mains Identity, Status and overview is shown at the top of every page. Mains and Site Identity are set using the DSE Config Suite Software. Control buttons to mimic the module s own fascia mounted buttons. Availability of some buttons depends upon the module type. The vertical green bar shows the module s current operating mode. Indicates the current page selected. Click the buttons to change the page. 41

42 Operation Mains Controller UTILITY (MAINS) Indicates that this is page 1 of 9 in this section. Press to move between the different pages including bar graph display: In line with normal convention: Positive (+) power factor is lagging power factor Negative (-) power factor is leading power factor ISSUE: 8 Page 42 of 58

43 Operation Mains Controller BUS Indicates that this is page 1 of 3 in this section. Press to move between the different pages including bargraph display: Page 43 of ISSUE: 8

44 Operation Mains Controller ALARMS Indicates that this is page 1 of 2 in this section. Press to move between the current alarms and the past event log : Alarm level Warning Electrical trip Shutdown Colour/Title graphic ISSUE: 8 Page 44 of 58

45 Operation Mains Controller I/O NOTE: Additional I/O is available when DSE86xx MKII modules are connected, this additional I/O is displayed in the DSE8005 SCADA Suite Software INPUTS State of the input (open or closed to battery negative) Shows if the input channel is active or not. This input is closed and is active. The input is configured to be close to activate The function the input is configured for Indicates that this is page 1 of 6 in this section. Press to move between the inputs, outputs and expansion modules:. Page 45 of ISSUE: 8

46 Operation Mains Controller OUTPUTS State of the output (on/closed or off/open) Shows if the output channel is active or not. This output is normally closed and the output is closed and is active. The output is configured to be de-energise. Shows if the output channel is active or not. This output is off and is not active. The output is configured to be energise. The function the output is configured for ISSUE: 8 Page 46 of 58

47 Operation Mains Controller EXPANSION MODULES Shows the type expansion module and if communication is active or not. If multiple expansion modules of the same type are connected, press the ID number to view a different module. The function the expansion device is configured for Shows if the expansion channel is active or not. Indicates that this is page 4 of 6 in this section. Press to move between the different types expansion modules and the inputs and outputs:. Page 47 of ISSUE: 8

48 Operation Mains Controller REMOTE CONTROL NOTE: Check the modules configuration before activating a remote control channel. Activating a remote control channel can change the operation of the DSE module. Shows if the remote control channel is active or not Press to turn the control on Press to turn the control off ISSUE: 8 Page 48 of 58

49 Operation Mains Controller VIRTUAL LEDS Shows if the virtual LED is active or not The function the virtual LED is configured for Indicates that this is page 6 of 6 in this section. Press to move between the inputs, outputs and expansion modules:. Page 49 of ISSUE: 8

50 Operation Mains Controller ABOUT Shows the PC Software and module firmware version numbers ISSUE: 8 Page 50 of 58

51 Operation Bus Tie Controller 5.5 BUS TIE CONTROLLER HOME Bus-Tie Identity, Status and overview is shown at the top of every page. Bus-Tie and Site Identity are set using the DSE Config Suite Software. Control buttons to mimic the module s own fascia mounted buttons. Availability of some buttons depends upon the module type. The vertical green bar shows the module s current operating mode. Indicates the current page selected. Click the buttons to change the page. 51

52 Operation Bus Tie Controller BUS The analogue dials relate to which ever parameter is highlighted at the time. Indicates that this is page 1 of 5 in this section. Press to move between the different pages including bargraph display: ISSUE: 8 Page 52 of 58

53 Operation Bus Tie Controller ALARMS Indicates that this is page 1 of 2 in this section. Press to move between the current alarms and the past event log : Alarm level Warning Electrical trip Colour/Title graphic. Page 53 of ISSUE: 8

54 Operation Bus Tie Controller I/O INPUTS State of the input (open or closed to battery negative) Shows if the input channel is active or not. This input is closed and is active. The input is configured to be close to activate The function the input is configured for Indicates that this is page 1 of 6 in this section. Press to move between the inputs and outputs of both the module and its expansion modules: ISSUE: 8 Page 54 of 58

55 Operation Bus Tie Controller OUTPUTS State of the output (on/closed or off/open) Shows if the output channel is active or not. This output is closed and is active. The output is configured to be energise. The function the output is configured for Page 55 of ISSUE: 8

56 Operation Bus Tie Controller EXPANSION MODULES Shows the type expansion module and if communication is active or not. If multiple expansion modules of the same type are connected, press the ID number to view a different module. The function the expansion device is configured for Shows if the expansion channel is active or not. Indicates that this is page 3 of 3 in this section. Press to move between the different types expansion modules and the inputs and outputs: ISSUE: 8 Page 56 of 58

57 Operation Bus Tie Controller ABOUT Shows the PC Software and module firmware version numbers Page 57 of ISSUE: 8

58 This Page Intentionally Blank

DEEP SEA ELECTRONICS

DEEP SEA ELECTRONICS COMPLEX SOLUTIONS MADE SIMPLE DEEP SEA ELECTRONICS DSE SCADA Suite Software Document Number 057-128 ISSUE 3 Author: Anthony Manton DEEP SEA ELECTRONICS PLC Highfield House Hunmanby North Yorkshire YO14

More information

DEEP SEA ELECTRONICS PLC

DEEP SEA ELECTRONICS PLC DEEP SEA ELECTRONICS PLC DSE855 USB to Ethernet Convertor Operator Manual Document Number: 057-205 Author: Anthony Manton DSE855 USB to Ethernet Convertor Operator Manual ISSUE 4 DSE855 USB to Ethernet

More information

DSEEXTRA. DSE860 RS232 Ethernet Adaptor DSE865 RS485 Ethernet Adaptor Document Number Author : Anthony Manton

DSEEXTRA. DSE860 RS232 Ethernet Adaptor DSE865 RS485 Ethernet Adaptor Document Number Author : Anthony Manton COMPLEX SOLUTIONS MADE SIMPLE DSEEXTRA DSE860 RS232 Ethernet Adaptor DSE865 RS485 Ethernet Adaptor Document Number 057-099 Author : Anthony Manton Deep Sea Electronics Plc Highfield House Hunmanby North

More information

DEEP SEA ELECTRONICS PLC

DEEP SEA ELECTRONICS PLC DEEP SEA ELECTRONICS PLC DSE857 Configuration Suite PC Software and Operator Manual Document Number: 057-219 Author: Tony Manton DSE857 Configuration Suite PC Software and Operator Manual ISSUE 1 DSE857

More information

DSE8610 SYNCHRONISING AUTO START LOAD SHARE CONTROL MODULE DSE COMPREHENSIVE FEATURE LIST TO SUIT A WIDE VARIETY OF LOAD SHARE APPLICATIONS FEATURES

DSE8610 SYNCHRONISING AUTO START LOAD SHARE CONTROL MODULE DSE COMPREHENSIVE FEATURE LIST TO SUIT A WIDE VARIETY OF LOAD SHARE APPLICATIONS FEATURES DSE DSE8610 SYNCHRONISING AUTO START LOAD SHARE CONTROL MODULE FEATURES ENVIRONMENTAL TESTING STANDARDS ELECTRO MAGNETIC COMPATIBILITY BS EN 61000-6-2 EMC Generic Immunity Standard for the Industrial Environment

More information

DEEP SEA ELECTRONICS PLC DSE334 Configuration Suite Software Manual

DEEP SEA ELECTRONICS PLC DSE334 Configuration Suite Software Manual DEEP SEA ELECTRONICS PLC DSE334 Configuration Suite Software Manual Document Number 057-156 Author: Paul Gibbons DSE334 Configuration Suite Software Manual ISSUE 1 DSE334 Configuration Suite Software Manual

More information

DEEP SEA ELECTRONICS PLC DSE8610 Control Module

DEEP SEA ELECTRONICS PLC DSE8610 Control Module DEEP SEA ELECTRONICS PLC DSE8610 Control Module Document number 057-115 Author : Anthony Manton DSE8610 Operator Manual Issue 5 DSE8610 Control & Instrumentation System Operators Manual Deep Sea Electronics

More information

TYPICAL WIRING DIAGRAM A larger diagram is available in the operators manual. SEA ELECTRONICS 8620 INSTALLATION INSTRUCTIONS ISSUE 1

TYPICAL WIRING DIAGRAM A larger diagram is available in the operators manual. SEA ELECTRONICS 8620 INSTALLATION INSTRUCTIONS ISSUE 1 TYPICAL WIRING DIAGRAM A larger diagram is available in the operators manual. DEEP SEA ELECTRONICS 8620 INSTALLATION INSTRUCTIONS 053-129 ISSUE 1 ACCESSING THE FRONT PANEL CONFIGURATION EDITOR. Ensure

More information

DEEP SEA ELECTRONICS PLC DSEWebNet PC Internet Browser Software Manual

DEEP SEA ELECTRONICS PLC DSEWebNet PC Internet Browser Software Manual DEEP SEA ELECTRONICS PLC DSEWebNet PC Internet Browser Software Manual Document Number: 057-168 Author: Ashley Senior ISSUE: 5 DSEWebNet PC Internet Browser Software Manual DEEP SEA ELECTRONICS PLC Highfield

More information

DEEP SEA ELECTRONICS PLC

DEEP SEA ELECTRONICS PLC DEEP SEA ELECTRONICS PLC DSE892 SNMP Gateway Manual Document Number : 057-179 Author : Anthony Manton DSE892 SNMP Gateway Manual ISSUE 1 DSE892 SNMP Gateway Manual Deep Sea Electronics Plc Highfield House

More information

DEEP SEA ELECTRONICS PLC

DEEP SEA ELECTRONICS PLC DEEP SEA ELECTRONICS PLC 7xx series configuration software for Windows Software Manual Author Anthony Manton Deep Sea Electronics Plc Highfield House Hunmanby Industrial Estate North Yorkshire YO14 0PH

More information

DEEP SEA ELECTRONICS PLC DSE8860 Controller Operators Manual

DEEP SEA ELECTRONICS PLC DSE8860 Controller Operators Manual DEEP SEA ELECTRONICS PLC DSE8860 Controller Operators Manual Document Number: 057-173 Author: Ashley Senior DSE8860 Operators Manual ISSUE 1 DSE8860 Operators Manual DEEP SEA ELECTRONICS PLC Highfield

More information

DEEP SEA ELECTRONICS PLC

DEEP SEA ELECTRONICS PLC DEEP SEA ELECTRONICS PLC DSE2133 DSEnet RTD / Thermocouple Input Expansion Module Operator Manual Document number 057-140 Author : Anthony Manton DSE2131 DSEnet RTD / Thermocouple Input Expansion Module

More information

DEEP SEA ELECTRONICS PLC DSEE800 Operator Manual

DEEP SEA ELECTRONICS PLC DSEE800 Operator Manual DEEP SEA ELECTRONICS PLC DSEE800 Operator Manual Document Number: 057-202 Author: Ashley Senior DSEE800 Operator Manual ISSUE 4 DSEE800 Operator Manual DEEP SEA ELECTRONICS PLC Highfield House Hunmanby

More information

DEEP SEA ELECTRONICS PLC DSE103 MK II Speed Switch Operators Manual

DEEP SEA ELECTRONICS PLC DSE103 MK II Speed Switch Operators Manual DEEP SEA ELECTRONICS PLC DSE103 MK II Speed Switch Operators Manual Document number 057-135 Author : Paul Gibbons DSE103 MKII Operator Manual Issue 1 Deep Sea Electronics Plc Highfield House Hunmanby North

More information

DEEP SEA ELECTRONICS

DEEP SEA ELECTRONICS COMPLEX SOLUTIONS MADE SIMPLE DEEP SEA ELECTRONICS DSE8600 Series PC configuration suite Document Number 057-119 Author: Anthony Manton 8600 Configuration Suite Software Manual ISSUE 2 8600 Configuration

More information

DEEP SEA ELECTRONICS PLC

DEEP SEA ELECTRONICS PLC COMPLEX SOLUTIONS MADE SIMPLE DEEP SEA ELECTRONICS PLC DSE705 ATS CONTROL MODULE OPERATING MANUAL Deep Sea Electronics Plc Highfield House Hunmanby North Yorkshire YO14 0PH ENGLAND Sales Tel: +44 (0) 1723

More information

DSE2548 DSENET OUTPUT EXPANSION MODULE. DSEGenset DSE2548 COMPREHENSIVE FEATURE LIST TO SUIT A WIDE VARIETY OF GEN-SET APPLICATIONS

DSE2548 DSENET OUTPUT EXPANSION MODULE. DSEGenset DSE2548 COMPREHENSIVE FEATURE LIST TO SUIT A WIDE VARIETY OF GEN-SET APPLICATIONS DSEGenset DSE2548 DSENET OUTPUT EXPANSION MODULE ENVIRONMENTAL TESTING STANDARDS ELECTRO-MAGNETIC COMPATIBILITY BS EN 61000-6-2 EMC Generic Immunity Standard for the Industrial Environment BS EN 61000-6-4

More information

DEEP SEA ELECTRONICS PLC

DEEP SEA ELECTRONICS PLC DEEP SEA ELECTRONICS PLC 5xxx series configuration software for Windows For 55xx series controllers. Authors Anthony Manton Deep Sea Electronics Plc Highfield House Hunmanby Industrial Estate North Yorkshire

More information

DEEP SEA ELECTRONICS PLC

DEEP SEA ELECTRONICS PLC COMPLEX SOLUTIONS MADE SIMPLE. DEEP SEA ELECTRONICS PLC DSE5520 AUTOMATIC MAINS FAILURE CONTROL MODULE OPERATING MANUAL Deep Sea Electronics Plc Highfield House Hunmanby North Yorkshire YO14 0PH ENGLAND

More information

DSEPOWER. DSE8721 Colour Remote Display Module. Document number Author : Anthony Manton

DSEPOWER. DSE8721 Colour Remote Display Module. Document number Author : Anthony Manton DSEPOWER DSE8721 Colour Remote Display Module Document number 057-126 Author : Anthony Manton Part No. 057-115 DSE8721 OPERATING MANUAL ISSUE 3.1 21/09/2010 ADM 1 DSE8721 Control & Instrumentation System

More information

DEEP SEA ELECTRONICS PLC

DEEP SEA ELECTRONICS PLC COMPLEX SOLUTIONS MADE SIMPLE. DEEP SEA ELECTRONICS PLC DSE4130 AUTOMATIC TRANSFER SWITCH CONTROL MODULE OPERATING MANUAL Deep Sea Electronics Plc Highfield House Hunmanby North Yorkshire YO14 0PH ENGLAND

More information

DEEP SEA ELECTRONICS PLC

DEEP SEA ELECTRONICS PLC DEEP SEA ELECTRONICS PLC DSE60xx Series Control Module Document Number 057-112 Author : Anthony Manton http://bestgenerator.spb.ru/?page_id=6765 DSE Model 60xx Series Control and Instrumentation System

More information

DEEP SEA ELECTRONICS PLC

DEEP SEA ELECTRONICS PLC COMPLEX SOLUTIONS MADE SIMPLE. DEEP SEA ELECTRONICS PLC DSE5320 AUTO MAINS FAILURE MODULE OPERATING MANUAL http://bestgenerator.spb.ru/?page_id=6765 Deep Sea Electronics Plc Highfield House Hunmanby North

More information

DSEPOWER DSE7510 Control Module Document Number

DSEPOWER DSE7510 Control Module Document Number DSEPOWER DSE7510 Control Module Document Number 057-088 Author : Anthony Manton http://bestgenerator.spb.ru/?page_id=6765 Deep Sea Electronics Plc Highfield House Hunmanby North Yorkshire YO14 0PH ENGLAND

More information

DEEP SEA ELECTRONICS DSE890 / DSE891 GATEWAY INSTALLATION INSTRUCTIONS

DEEP SEA ELECTRONICS DSE890 / DSE891 GATEWAY INSTALLATION INSTRUCTIONS DEEP SEA ELECTRONICS 890 / 891 GATEWAY INSTALLATION INSTRUCTIONS 053-140 ISSUE 3.1 The Gateway communicates to the connected controller(s) monitoring the instrumentation and operating state. If the data

More information

DSEPOWER. DSE7520 MK1 Mains Control Module. Document Number Author : Anthony Manton

DSEPOWER. DSE7520 MK1 Mains Control Module. Document Number Author : Anthony Manton DSEPOWER DSE7520 MK1 Mains Control Module Document Number 057-090 Author : Anthony Manton Deep Sea Electronics Plc Highfield House Hunmanby North Yorkshire YO14 0PH ENGLAND Sales Tel: +44 (0) 1723 890099

More information

DEEP SEA ELECTRONICS PLC DSE334 ATS Controller Operators Manual

DEEP SEA ELECTRONICS PLC DSE334 ATS Controller Operators Manual DEEP SEA ELECTRONICS PLC DSE334 ATS Controller Operators Manual Document Number 057-154 Author: Allan Jones DSE 334 ATS Controller Operators Manual Issue 1 DSE 334 ATS Controller Operators Manual Deep

More information

DSEULTRA DSE6100 Series Control Module Document Number

DSEULTRA DSE6100 Series Control Module Document Number DSEULTRA DSE6100 Series Control Module Document Number 057-095 Author : Anthony Manton http://bestgenerator.spb.ru/?page_id=6765 DSE Model 6000 Series Control and Instrumentation System Operators Manual

More information

DSEULTRA DSE3110 Series Control Module

DSEULTRA DSE3110 Series Control Module DSEULTRA DSE3110 Series Control Module 057-086 Author : Anthony Manton DSE Model 3000 Series Control and Instrumentation System Operators Manual Deep Sea Electronics Plc Highfield House Hunmanby North

More information

DEEP SEA ELECTRONICS PLC DSE7310 MKII & DSE7320 MKII Operator Manual

DEEP SEA ELECTRONICS PLC DSE7310 MKII & DSE7320 MKII Operator Manual DEEP SEA ELECTRONICS PLC DSE7310 MKII & DSE7320 MKII Operator Manual Document Number: 057-253 Author: Ashley Senior 057-253 ISSUE: 3 DSE7310 MKII & DSE7320 MKII Operator Manual Deep Sea Electronics Plc

More information

DEEP SEA ELECTRONICS PLC DSE7310 MKII & DSE7320 MKII Operator Manual

DEEP SEA ELECTRONICS PLC DSE7310 MKII & DSE7320 MKII Operator Manual DEEP SEA ELECTRONICS PLC DSE7310 MKII & DSE7320 MKII Operator Manual Document Number: 057-253 Author: Ashley Senior 057-253 ISSUE: 1 DSE7310 MKII & DSE7320 MKII Operator Manual Deep Sea Electronics Plc

More information

RS-232 Connector Pin Assignments

RS-232 Connector Pin Assignments APPENDIXB This appendix lists the connector pin assignments for the CDEs, and includes the following sections: Serial Console-Interface, page B- Ethernet, page B- Cable Pin Assignments, page B- Serial

More information

DSE2510/20 REMOTE DISPLAY MODULES. DSEGenset DSE2510/20 COMPREHENSIVE FEATURE LIST TO SUIT A WIDE VARIETY OF GEN-SET APPLICATIONS FEATURES

DSE2510/20 REMOTE DISPLAY MODULES. DSEGenset DSE2510/20 COMPREHENSIVE FEATURE LIST TO SUIT A WIDE VARIETY OF GEN-SET APPLICATIONS FEATURES DSEGenset DSE2510/20 REMOTE DISPLAY MODULES FEATURES The DSE2510 and DSE2520 are display modules designed to work with the DSE7310 Auto Start and DSE7320 Auto Mains (utility) Failure control modules. Up

More information

-C5RS-LC RS232 EXTENDER

-C5RS-LC RS232 EXTENDER XTENDEX Series ST-C5RS-LC RS232 EXTENDER Installation and Operation Manual ST-C5RS-LC RS232 Extender Man249 Rev. 10/30/17 TRADEMARK XTENDEX is a registered trademark of Network Technologies Inc in the

More information

USER S MANUAL. PH232Ex1. #1 RS-232 Serial Port to Ethernet, Terminal Server/Client. Doc No: PH232Ex1-UM-001 IPEX. (IP Electronix)

USER S MANUAL. PH232Ex1. #1 RS-232 Serial Port to Ethernet, Terminal Server/Client. Doc No: PH232Ex1-UM-001 IPEX. (IP Electronix) USER S MANUAL PH232Ex1 Doc No: PH232Ex1-UM-001 #1 RS-232 Serial Port to Ethernet, Terminal Server/Client IPEX (IP Electronix) Contents 1. INTRODUCTION... 3 2. SPECIFICATIONS... 3 3. PACKAGE CHECKLIST...

More information

Document Name: User Manual for SC10MK, Modbus RTU to Modbus TCP Converter

Document Name: User Manual for SC10MK, Modbus RTU to Modbus TCP Converter Document Name: User Manual for SC10MK, Modbus RTU to Modbus TCP Converter Login for the first time, please use http://192.168.1.100 To key in user name and password is for identifying authorization. Default

More information

MIU-1000 v. Revised: 4/20/2009. Copyright 2008, Traf-SYS, Inc.

MIU-1000 v. Revised: 4/20/2009. Copyright 2008, Traf-SYS, Inc. MIU-1000 v 2.6g Revised: 4/20/2009 Copyright 2008, Traf-SYS, Inc. Contents Introduction... 3 Setting up your MIU-1000 for the first time... 3 Connections... 3 Connecting with a Serial Cable... 3 Connecting

More information

NM-541-MUX TECHNICAL APENDIX V1.00

NM-541-MUX TECHNICAL APENDIX V1.00 NM-541-MUX Five Inputs NMEA Multiplexer TECHNICAL APENDIX V1.00 26, Myrtidiotissis str. Kastella 185-33 Piraeus Greece Tel +30 210 4134628 & +30 210 4134698 Fax +30 210 4134814 Web: http://www.nuovamarea.com

More information

THE RAINBOW SCADA D-700

THE RAINBOW SCADA D-700 THE RAINBOW SCADA D-700 INTERNET ENABLED SYNCHRONIZATION SYSTEM REV-03 25.12.2014 EXPANSION CAPACITY MAX 16 LOADS MAX 48 GENSETS MAX 4 BUS COUPLERS MAX 16 MAINS MULTIFUNCTIONAL THE SAME UNIT IS A... MULTI-GENSET

More information

Advanced Graphical Interface, AGI 100

Advanced Graphical Interface, AGI 100 APPLICATION NOTES Advanced Graphical Interface, AGI 100 The AGI communication ports Modbus details Specific DEIF driver Example of project creation Document no.: 4189340746A DEIF Screen Designer 1.293

More information

APPLICATION NOTE. Rainbow Scada Usage Guide. Tel: Fax:

APPLICATION NOTE. Rainbow Scada Usage Guide. Tel: Fax: Tel: +90-216 466 84 60 Fax: +90-216 364 65 65 datakom@datakom.com.tr http://www.datakom.com.tr APPLICATION NOTE Rainbow Scada Usage Guide PRODUCTS AFFECTED: D-500 / D-700 WRITTEN BY: Metin Hekimoglu DATE:

More information

ES-511, ES-522, ES-551, ES-571. Quick Start Guide. for Brainboxes Ethernet to Serial Range

ES-511, ES-522, ES-551, ES-571. Quick Start Guide. for Brainboxes Ethernet to Serial Range ES-511, ES-522, ES-551, ES-571 Quick Start Guide for Brainboxes Ethernet to Serial Range Contents 1. Box Contents Check List 3 2. Hardware 4 3. Network IP Addressing 6 4. Connecting your ES Device 7 5.

More information

Dominion KX II-101-V2

Dominion KX II-101-V2 Dominion KX II-101-V2 Quick Setup Guide Thank you for your purchase of the KX II-101-V2, the industry's most full-featured, enterprise-class, secure, digital KVM (Keyboard, Video, Mouse) switch. This Quick

More information

HARNESS INFORMATION TECHNICAL DOCUMENTATION

HARNESS INFORMATION TECHNICAL DOCUMENTATION HARNESS INFORMATION TECHNICAL DOCUMENTATION Part Number: A53 W0 9 0002-B-EN Last Update: 05/2018 CRE Technology believes that all information provided herein is correct and reliable and reserves the right

More information

Single Channel Video Insert Unit with Bi-directional Data Channel for a Dual Redundant fibre ring

Single Channel Video Insert Unit with Bi-directional Data Channel for a Dual Redundant fibre ring AMG3613DRSF Instruction Manual Single Channel Video Insert Unit with Bidirectional Data Channel for a Dual Redundant fibre ring The AMG3613DRSF is a standalone single channel video insert unit designed

More information

INTEGRATED SYSTEMS AND CONTROL, INC. User s Hardware Manual. PCMNET V 7. xx

INTEGRATED SYSTEMS AND CONTROL, INC. User s Hardware Manual. PCMNET V 7. xx INTEGRATED SYSTEMS AND CONTROL, INC. User s Hardware Manual PCMNET V 7. xx INTEGRATED SYSTEMS AND CONTROLS, INC. PCMNET Users Manual Revised 2/4/2005 2003-2005 Integrated Systems and Control. Inc. PO Box

More information

AX3000 Platine Terminal Ethernet TCP/IP

AX3000 Platine Terminal Ethernet TCP/IP AX3000 Platine Terminal Ethernet TCP/IP Model 60 Installation Guide September 00 - Ref: I60IE010-1 Model AX3000/M60 The reproduction of this material, in part or whole, is strictly prohibited. For additional

More information

Innovative Electronics for a Changing World INDEX

Innovative Electronics for a Changing World INDEX Innovative Electronics for a Changing World INDEX 1. SYSTEM DESCRIPTION 2. BOARD CONNECTIONS terminals and indicators 3. CONNECTION DIAGRAM 4. START UP GUIDE and passwords 5. HOME PAGE 6. STATUS PAGE 7.

More information

IntesisBox Modbus Server KILSEN KSA-7xx. User s Manual 08/2013 r1.2 eng

IntesisBox Modbus Server KILSEN KSA-7xx. User s Manual 08/2013 r1.2 eng IntesisBox Modbus Server KILSEN KSA-7xx User s Manual 08/2013 r1.2 eng Intesis Software S.L. 2013 All rights reserved. Information in this document is subject to change without notice. The software described

More information

DARK1616M DANTE NETWORK AUDIO 16 INPUT 16 OUTPUT AES3 & MIC/LINE LEVEL ANALOGUE INTERFACE PRODUCT DETAILS

DARK1616M DANTE NETWORK AUDIO 16 INPUT 16 OUTPUT AES3 & MIC/LINE LEVEL ANALOGUE INTERFACE PRODUCT DETAILS DARK1616M DANTE NETWORK AUDIO 16 INPUT 16 OUTPUT AES3 & MIC/LINE LEVEL ANALOGUE INTERFACE PRODUCT DETAILS 6 BROOKS PLACE, MAIDSTONE, KENT, ME14 1HE. ENGLAND. TEL: +44 (0) 1622 753662 Visit our Website

More information

Data Insert Unit with 2 Bi-directional Data Channels for a Dual Redundant Singlemode Fibre Ring

Data Insert Unit with 2 Bi-directional Data Channels for a Dual Redundant Singlemode Fibre Ring AMG3703B2DRSF Instruction Manual Data Insert Unit with 2 Bidirectional Data Channels for a Dual undant Singlemode Fibre Ring The AMG3703B2DRSF is a standalone data insert unit designed to transmit and

More information

Introduction to the Autologic Vehicle Diagnostic Tool

Introduction to the Autologic Vehicle Diagnostic Tool Introduction to the Autologic Vehicle Diagnostic Tool User Instructions Version 4.0 Issued April 2012 For the latest version of this document see www.autologic.com Ltd has made every effort to make sure

More information

Quick Installation Guide

Quick Installation Guide Quick Installation Guide DL-200 Cellular Data logger V1.2_201610 TABLE OF CONTENTS CHAPTER 1 INTRODUCTION... 4 1.1 CONTENTS LIST... 5 1.2 HARDWARE INSTALLATION... 6 1.2.1 WARNING... 6 1.2.2 SYSTEM REQUIREMENTS...

More information

Two-way C-BUS Interface for Ness D8x/D16x Control Panels. Installation & Programming Manual. Rev2

Two-way C-BUS Interface for Ness D8x/D16x Control Panels. Installation & Programming Manual. Rev2 Two-way C-BUS Interface for Ness D8x/D16x Control Panels Manual Rev2 www.nesscorporation.com National Customer Service Centre Ph: 1300 551 991 customerservice@ness.com.au MiniCENTRAL C-BUS Manual Rev2

More information

RM6000 GPRS Modem / Router

RM6000 GPRS Modem / Router User Manual Version 6.30 AMG Systems Ltd March 2013 3 The Omega Centre Stratton Business Park Biggleswade Bedfordshire, UK SG18 8QB Tel: 44 (0) 1767 600777 sales@amgsystems.com 1. Introduction 2. RM6000

More information

DEEP SEA ELECTRONICS PLC

DEEP SEA ELECTRONICS PLC DEEP SEA ELECTRONICS PLC Guide to Synchronising and Load Sharing PART 1 Usage and configuration of the 55x in synchronisation / load sharing systems. Author: - Anthony Manton DSE Guide to Synchronising

More information

ACTpro Single Door IP Controller. Operating & Installation Instructions

ACTpro Single Door IP Controller. Operating & Installation Instructions ACTpro 1500 Single Door IP Controller Operating & Installation Instructions 18-00079 Issue 1 This manual refers to the ACTpro 1500 a TCP/IP based control unit supporting up to 32 doors. Access Control

More information

E-ACLM-V E-ACLM-P12/8/18 AC LINE MONITORS Installation and Operation Manual

E-ACLM-V E-ACLM-P12/8/18 AC LINE MONITORS Installation and Operation Manual NTI R NETWORK 1275 Danner Dr Tel:330-562-7070 TECHNOLOGIES Aurora, OH 44202 Fax:330-562-1999 INCORPORATED www.networktechinc.com ENVIROMUX Series E-ACLM-V E-ACLM-P12/8/18 AC LINE MONITORS Installation

More information

MANUAL. EM Cable and DSL Router

MANUAL. EM Cable and DSL Router MANUAL EM4420 - Cable and DSL Router WWW.EMINENT-ONLINE.COM 2 ENGLISH EM4420 - Cable and DSL Router Warnings and points of attention Opening a product and/or products may cause serious injuries! Always

More information

BiPAC 7300 series. Quick Install Guide

BiPAC 7300 series. Quick Install Guide BiPAC 7300 series Quick Install Guide for 7300 and 7300G ADSL2/2+ Modem/Routers QoS Firewall Wireless Multi-Port Switching Hub Quick Install Guide This guide covers only the initial Internet set-up. Please

More information

DATA SHEET Compact Genset Controller, CGC 200

DATA SHEET Compact Genset Controller, CGC 200 DATA SHEET Compact Genset Controller, CGC 200 Auto start and parameter monitoring Warnings and shutdown protections Includes 5 digital inputs, 5 relay outputs Configurable for other applications Licence-free

More information

NET101. RS232 / RS422 / RS485 to Ethernet Converter. User s Manual. Version 1.2

NET101. RS232 / RS422 / RS485 to Ethernet Converter. User s Manual. Version 1.2 NET101 RS232 / RS422 / RS485 to Ethernet Converter User s Manual Version 1.2 Copyright Information Copyright 2004-2005, Mega System Technologies, Inc. All rights reserved. Reproduction without permission

More information

Industrial IP67-rated 4-Port 10/100/1000T at PoE + 2-Port 10/100/1000T. M12 Managed Ethernet Switch. (-40~75 degrees C) IGS-604HPT-M12

Industrial IP67-rated 4-Port 10/100/1000T at PoE + 2-Port 10/100/1000T. M12 Managed Ethernet Switch. (-40~75 degrees C) IGS-604HPT-M12 Industrial IP67-rated 4-Port 10/100/1000T 802.3at PoE + 2-Port 10/100/1000T M12 Managed Ethernet Switch (-40~75 degrees C) IGS-604HPT-M12 Quick Installation Guide Table of Contents 1. Package Contents...

More information

QUICK START GUIDE Paralleling and Protection Unit PPU 300

QUICK START GUIDE Paralleling and Protection Unit PPU 300 QUICK START GUIDE Paralleling and Protection Unit PPU 300 DEIF A/S Frisenborgvej 33 DK-7800 Skive Tel.: +45 9614 9614 Fax: +45 9614 9615 info@deif.com www.deif.com Document no.: 4189341107C 1. Introduction

More information

THE RAINBOW SCADA D-500-LITE

THE RAINBOW SCADA D-500-LITE THE RAINBOW SCADA D-500-LITE INTERNET ENABLED GENSET CONTROLLER REV-03 25.12.2014 MULTIFUNCTIONAL THE SAME UNIT IS A... AMF UNIT ATS CONTROLLER REMOTE START CONTROLLER ENGINE CONTROLLER REMOTE DISPLAY

More information

Model 375 Ethernet Software LMI Part No Software Manual Version October 2013

Model 375 Ethernet Software LMI Part No Software Manual Version October 2013 Model 375 Ethernet Software LMI Part No. 1370-055 Software Manual Version 1.5.2 Model 375 Ethernet Software LMI Part No. 1370-055 Software Manual Version 1.5.2 TABLE OF CONTENTS 1. General... 1 2. Installation...

More information

Technical Manual Nova: Cabinet Security Management System (CSMS)

Technical Manual Nova: Cabinet Security Management System (CSMS) Technical Manual Nova: Cabinet Security Management System (CSMS) KP_nova_TM_160501_EN 1 Publication May, 2016, Keyprocessor BV Paasheuvelweg 20 1105BJ Amsterdam, The Netherlands www.keyprocessor.com/nova

More information

IntesisBox Modbus Server Fidelio IP

IntesisBox Modbus Server Fidelio IP IntesisBox Modbus Server Fidelio IP User Manual r1 eng Issue Date: 10/04/2014 Intesis Software S.L. All Rights Reserved. Information in this document is subject to change without notice. The software described

More information

SAGEMCOM 5355 GATEWAY

SAGEMCOM 5355 GATEWAY SAGEMCOM F@ST 5355 GATEWAY Disclaimer This is not an official document. I am not employed by Telstra nor am I an IT person. I wrote this document because setting up my gateway was a hassle due to the lack

More information

Cellwatch System Overview

Cellwatch System Overview Cellwatch System Overview The Cellwatch system is built using modules. The majority of the system is constructed with Data Collection Modules (DCMs). The DCMs are optically linked to Control Units (CUs)

More information

Manual# Installation Manual SDU 410. Safety Shutdown Unit

Manual# Installation Manual SDU 410. Safety Shutdown Unit Manual# 1100641 Installation Manual SDU 410 Safety Shutdown Unit Installation Manual for SDU 410 ~~~ Safety Shutdown Unit Revision 1.0 Revised August 31, 2017 Revision history: Rev. Date Description 1.0

More information

Industrial IP67-rated. 4-Port 10/100/1000T 802.3at PoE. + 2-Port 10/100/1000T. Managed Ethernet Switch (-40~75 degrees C, 24V) IGS MP2MT

Industrial IP67-rated. 4-Port 10/100/1000T 802.3at PoE. + 2-Port 10/100/1000T. Managed Ethernet Switch (-40~75 degrees C, 24V) IGS MP2MT Industrial IP67-rated 4-Port 10/100/1000T 802.3at PoE + 2-Port 10/100/1000T Managed Ethernet Switch (-40~75 degrees C, 24V) IGS-5227-4MP2MT Quick Installation Guide Table of Contents 1. Package Contents...

More information

RTU8 Compact Telemetry Outstation IOTOOL32 PRO Software. Getting Started Guide

RTU8 Compact Telemetry Outstation IOTOOL32 PRO Software. Getting Started Guide 1 RTU8 Compact Telemetry Outstation IOTOOL32 PRO Software Getting Started Guide V. 1.00 / Feb 2006 / Doc 40031 2 1. Introduction The RTU8 range of Compact Telemetry Outstations provide an efficient and

More information

QUICK START GUIDE Paralleling and Protection Unit PPU 300

QUICK START GUIDE Paralleling and Protection Unit PPU 300 QUICK START GUIDE Paralleling and Protection Unit PPU 300 DEIF A/S Frisenborgvej 33 DK-7800 Skive Tel.: +45 9614 9614 Fax: +45 9614 9615 info@deif.com www.deif.com Document no.: 4189341107B 1. Introduction

More information

BiPAC 7300GX. UK Quick Install Guide

BiPAC 7300GX. UK Quick Install Guide BiPAC 7300GX ADSL2/2+ Modem/Router with 3G back-up QoS Firewall Wireless Multi-Port Switching Hub UK Quick Install Guide This guide covers only the initial Internet set-up. Please refer to the full User

More information

TRAINING GUIDE LEVEL 3 MODBUS WRITE IMPORT COMMAND

TRAINING GUIDE LEVEL 3 MODBUS WRITE IMPORT COMMAND OleumTechTM TRAINING GUIDE LEVEL 3 MODBUS WRITE IMPORT COMMAND MUST BE FAMILIAR WITH LEVEL 1 TRAINING MATERIALS BEFORE MOVING FORWARD Doc ID# 80-6010-001b TABLE OF CONTENTS 1. WHAT IS NEW WRITE IMPORT

More information

ACTpro 1500 Single Door IP Controller

ACTpro 1500 Single Door IP Controller ACTpro 1500 Single Door IP Controller ACTpro 1520 Single Door IP Controller with 12 V DC 2 amp power supply. Operating & Installation Instructions 18-00085 Issue 2 This manual refers to the ACTpro 1500

More information

Dual Channel Video Insert Unit with Ethernet for a Dual Redundant fibre ring

Dual Channel Video Insert Unit with Ethernet for a Dual Redundant fibre ring AMG3721EDRSF Instruction Manual Dual Channel Video Insert Unit with Ethernet for a Dual Redundant fibre ring The AMG3721EDRSF is a standalone single channel video insert unit designed to transmit two video

More information

NCOM SERIAL DEVICE SERVER 1XX SERIES USER S MANUAL

NCOM SERIAL DEVICE SERVER 1XX SERIES USER S MANUAL NCOM SERIAL DEVICE SERVER 1XX SERIES USER S MANUAL 2017-07-07 Edition Titan Electronics Inc. Web: www.titan.tw Contents 1. INTRODUCTION... 4 1.1 Key Features... 5 1.2 Specifications... 6 2. PANEL LAYOUT

More information

UTM Content Security Gateway CS-2001

UTM Content Security Gateway CS-2001 UTM Content Security Gateway CS-2001 Quick Installation Guide Table of Contents 1. Package Contents... 3 2. Setup the UTM Content Security Gateway... 4 3. Hardware Installation... 5 4. Basic System Configuration...

More information

TCPIPINT-SCMN USER MANUAL. Manufactured by R.V.R ELETTRONICA S.p.A. Italy

TCPIPINT-SCMN USER MANUAL. Manufactured by R.V.R ELETTRONICA S.p.A. Italy USER MANUAL Manufactured by R.V.R S.p.A. Italy File Name: _ING_1.0.indb Version: 1.0 Date: 15/04/2016 Revision History Date Version Reason Editor 15/04/2016 1.0 First edition J. H. Berti - User Manual

More information

PMAC770 LAN Module User Manual V1.0

PMAC770 LAN Module User Manual V1.0 PMAC770 LAN Module User Manual V1.0 1 CONTENTS 1. Product Description... 3 1.1 WEB page data... 3 1.2 Functions... 3 1.3 Performance Specifications... 3 2. Installation and Wiring... 4 2.1 Environment...

More information

8 Channel Video Transmit Unit with 1 Bi-directional Data Channel for a Singlemode Fibre Link

8 Channel Video Transmit Unit with 1 Bi-directional Data Channel for a Singlemode Fibre Link AMG4783 Instruction Manual 8 Channel Video Transmit Unit with 1 Bi-directional Data Channel for a Singlemode Fibre Link The AMG4783 is a standalone eight channel video transmit unit designed to transmit

More information

SMM Series 3G and GSM Modems. Quick Start Guide. Document Number: Version: 1.2 (20 October, 2015)

SMM Series 3G and GSM Modems. Quick Start Guide. Document Number: Version: 1.2 (20 October, 2015) SMM Series 3G and GSM Modems Quick Start Guide Document Number: 0013-001-000272 () Documentation Control Generation Date: October 20, 2015 Cybertec Pty Limited All rights Reserved. No part of this publication

More information

USING THE XPERT2 / 9210B ON A TCP/IP NETWORK

USING THE XPERT2 / 9210B ON A TCP/IP NETWORK 1 USING THE XPERT2 / 9210B ON A TCP/IP NETWORK Prepared by: R&D January, 2009 Updated September 26, 2013 Sutron Corporation 22400 Davis Drive Sterling, Virginia 20164 TEL: (703) 406-2800 FAX: (703) 406-2801

More information

DSEM870. DSEControl PROGRAMMABLE DISPLAY FOR USE IN VEHICLES AND OFF-HIGHWAY MACHINERY

DSEM870. DSEControl PROGRAMMABLE DISPLAY FOR USE IN VEHICLES AND OFF-HIGHWAY MACHINERY PROGRAMMABLE DISPLAY FOR USE IN VEHICLES AND OFF-HIGHWAY MACHINERY OVERVIEW DC SUPPLY 8 V DC to 32 V DC CURRENT CONSUMPTION OPERATING CURRENT < 1000 ma at 12 V and 24 V without external loads < 1500 ma

More information

DSE2548 LED expansion module INTRODUCTION

DSE2548 LED expansion module INTRODUCTION DSE2548 LED expansion module INTRODUCTION The DSE2548 LED expansion module is used in conjunction with compatible DSE controllers to provide additional LED indication functionality. The LEDs are configured

More information

QUICK START GUIDE. Multi Display Controller

QUICK START GUIDE. Multi Display Controller Multi Display Controller QUICK START GUIDE Thank you for purchasing the Datapath Fx4-SDI multi display controller. The aim of this document is to quickly guide you through the process of initial setup.

More information

Dominion KX II-101. Quick Setup Guide. Step 1: Configure the Target Server

Dominion KX II-101. Quick Setup Guide. Step 1: Configure the Target Server Dominion KX II-101 Quick Setup Guide Thank you for your purchase of the KX II-101, the industry's most full-featured, enterprise-class, secure, digital KVM (Keyboard, Video, Mouse) switch. This Quick Setup

More information

GSM-X. Communication module. Quick installation guide. Full manual is available on Firmware version 1.02 gsm-x_sii_en 08/18

GSM-X. Communication module. Quick installation guide. Full manual is available on   Firmware version 1.02 gsm-x_sii_en 08/18 GSM-X Communication module Quick installation guide Full manual is available on www.satel.eu Firmware version 1.02 gsm-x_sii_en 08/18 SATEL sp. z o.o. ul. Budowlanych 66 80-298 Gdańsk Poland tel. +48 58

More information

THIS PAGE LEFT BLANK

THIS PAGE LEFT BLANK SOUND LEVEL LIMITER THIS PAGE LEFT BLANK IMPORTANT Installer and Users please note: These instructions should be read carefully and left with the user of the product for future reference. The must be installed

More information

Industrial IP67-rated 4-Port 10/100/1000T at PoE + 2-Port 10/100/1000T. Managed Ethernet Switch. (-40~75 degrees C) IGS-604HPT-RJ

Industrial IP67-rated 4-Port 10/100/1000T at PoE + 2-Port 10/100/1000T. Managed Ethernet Switch. (-40~75 degrees C) IGS-604HPT-RJ Industrial IP67-rated 4-Port 10/100/1000T 802.3at PoE + 2-Port 10/100/1000T Managed Ethernet Switch (-40~75 degrees C) IGS-604HPT-RJ Quick Installation Guide Table of Contents 1. Package Contents... 3

More information

FieldServer X-25 Start-Up Guide

FieldServer X-25 Start-Up Guide Sierra Monitor Company FieldServer X-25 Start-Up Guide APPLICABILITY & EFFECTIVITY Effective for all systems manufactured after April 2013 Kernel Version: 6.10 Document Revision: 0 FieldServer FS-X25 Start-Up

More information

8 Channel Video Transmit Unit with 1 Bi-directional Data Channel for a Singlemode Fibre Link

8 Channel Video Transmit Unit with 1 Bi-directional Data Channel for a Singlemode Fibre Link AMG4783R Instruction Manual 8 Channel Video Transmit Unit with 1 Bi-directional Data Channel for a Singlemode Fibre Link The AMG4783R is a rackmount eight channel video transmit unit designed to transmit

More information

Netbiter EC300 Series

Netbiter EC300 Series Netbiter EC300 Series USER MANUAL SCM-1202-012 2.2 ENGLISH Important User Information Liability Every care has been taken in the preparation of this document. Please inform HMS Industrial Networks AB of

More information

Installation and Operation Manual

Installation and Operation Manual Installation and Operation Manual ET1100C Series Ethernet Extender Series Microtype10/100BASE-TX Ethernet Extender over Coaxial Cable OT Systems Ltd., 2014 Rev 1.1 www.ot-systems.com 1 Models covered in

More information

INSTALLATION INSTRUCTIONS. DCC and DCE Installation Instructions. Table of Contents

INSTALLATION INSTRUCTIONS. DCC and DCE Installation Instructions. Table of Contents INSTALLATION INSTRUCTIONS MicroComm DXL DCC and DCE Installation Instructions Table of Contents 1. Intent & Scope 1 2. Description 1 3. DCC Backup Battery 2 4. Field Connections to the DCC 4 5. Field Connections

More information

Galaxy ACCeSS Lite Downloader

Galaxy ACCeSS Lite Downloader Galaxy ACCeSS Lite Downloader Installation and Operating Instructions Honeywell Security Table of contents Introduction...3 Note for Galaxy 3 series panels V5.0x...3 Installation...4 Set-up...4 Running

More information

AX3000 Platine Terminal Ethernet TCP/IP

AX3000 Platine Terminal Ethernet TCP/IP AX3000 Platine Terminal Ethernet TCP/IP Model 80 Installation Guide January 2012 - Ref: I80E0922-2 Model AX3000/M80 Type EA The reproduction of this material, in part or whole, is strictly prohibited.

More information