System 6000 Electropneumatic Converters (proportional valves) Electronic Controllers Signal Converters

Size: px
Start display at page:

Download "System 6000 Electropneumatic Converters (proportional valves) Electronic Controllers Signal Converters"

Transcription

1 System 6000 Electropneumatic Converters (proportional valves) Electronic Controllers Signal Converters Edition November 2003 Information Sheet T 6000 EN

2 Proportional valves e/p Converters Type Body style Rail-mounting unit 5) Field unit 7) Industrial unit Explosion protection EEx ia ATEX 9" rack-mounting unit, 7 HP 6) EEx ia, EEx d, ATEX, FM, CSA, Australian Standard ) Degree of protection IP 20 IP 54, IP 65, NEMA 4 IP 54, IP 65 IP 00 Field bus AS-Interface 4) Input 0 to 20 ma 4 to 20 ma 0 to 0 V 3) 2 to 0 V 3) Output 0.2 to bar 0.4 to 2 bar Special ranges up to 5 bar Special ranges up to 8 bar 2) Air supply 0.4 bar above upper signal pressure range, maximum 0 bar Max. 2.4 bar Electrical connection Phoenix terminal or male angle connector DIN A Pneumatic connection M0x,G 8; 8 NPT M20x NPT 4 NPT; G 4 Male angle connector DIN A 4 NPT; G 4 Electropneumatic plug connector Form F For further information, see Data Sheet: T 6 EN T 66 EN T 626 EN T 627 EN ) 2) 3) 4) 5) 6) 7) Further standards on request Not for EEx d devices With TROVIS 65 u/i Module With TROVIS 650 AS-Interface Module Also available as field unit with stainless steel enclosure Also available with two channels Special version for operation with natural gas on request 2 T 6000 EN

3 p/e Converters Type Body style Rail-mounting unit Rail-mounting unit Field unit Explosion protection EEx ia ), EEx d ) p/i converter unit or 2 Degree of protection IP 20 IP 20 IP 54, IP 65 Input 0.2 to bar Output 0 to 20 ma 4 to 20 ma 0 to 5 V to 5 V 0 to 0 V 2 to 0 V Power supply 230 VAC, 5 V AC, 24 V AC, 24 V DC 24 V DC Electrical connection Four wires Two wires Terminals for 0.5 to 2.5 mm 2 wires Terminals for 0.5 to 2.5 mm 2 wires M 20 x.5; 2 NPT; terminals for 0.5 to 2.5 mm 2 wires Pneumatic connection Hose connection 4 x Hose connection 4 x 4 NPT; G 4 For further information, see Data Sheet: T 632 EN T 634 EN ) Applied for Example of an application Type 632 ma Type 634 ma V 5 Transducer 2 Pneumatic converter 3 p/i converter 4 Controller 5 Two-wire network 3 T 6000 EN

4 Converter modules Type TROVIS 650 TROVIS 65 Designation AS-Interface module u/i module Intput AS-Interface 0 to 0 V 2 to 0 V Output 0 to 20 ma 4 to 20 ma Auxiliary power Over ASI line 6 to 30 V DC Electrical connection Male angle connector acc. to DIN A, M 20 x.5 (adapter connector) Input Auxiliary power Output Compatibility with SAMSON devices Positioners 3730, 3760, 376, 3767, 4763 V 200 valve 3372-IP i/p converters 6, 66, 626 R= U V H Max. load at the output: 300 Ω 20 ma e.g. 700 Ω at aux. power U H =24V For further information, see Data Sheet: T 650 EN T 65 EN Control level Field level Profibus PA, CAN, Interbus, DeviceNet, FIP, etc. MASTER GATEWAY SLAVE SLAVE SLAVE SLAVE SLAVE SLAVE ASI field level SAMSON Slave TROVIS T 6000 EN

5 Electronic Controllers Type TROVIS 6497 TROVIS 6493 TROVIS 642, TROVIS 6442 Style Panel-mounting unit Panel-mounting unit Panel-mounting unit (642) or 9" rack-mount. unit (6442) Degree of protection (front) IP 54 IP 65 IP 54 Inputs or 4 ma/ V Pt 00 (Pt 000, Ni 00, Ni 000) Thermocouple Potentiometer Transmitter supply Binary inputs 3 Outputs Continuous-action ouptut ma V On/off or three-step output or2 Analog output (with switching output) Limit relay 2 2 (with cont.-action output) 2 Binary output for alarm messages Binary outputs 2 (with cont.-action output) 2 Interfaces RS 485 RS 232 COPA pen Infrared Configuration program TROVIS-VIEW TROVIS 6482 Functions Fixed set point control Follow-up control Cascade control Limiting control Synchro control Ratio control P/PI/PID control Power supply 230/ 20/ 24 V AC 230/ 20/ 24 V AC 230/ 20/24 V AC, 24 V DC Refer to Data Sheet: T 6497 EN T 6493 EN T 642 EN 5 T 6000 EN

6 Application examples Controlling a positioning cylinder in the paper and printing industry The electric signal coming from a controller or a PLC (e) is converted to a pneumatic signal (p) by the e/p converter. The pressure signal is used to position a cylinder which, in turn, moves a roller that keeps the paper under a certain tension. e p Air Type 6 Controlling a valve Valves equipped with small pneumatic actuators can be controlled directly by an e/p converter. The e/p converter receives the electric signal from a controller or a PLC. The e/p converter can also control a pneumatic positioner. Type 324- TROVIS 6493 Field or industrial units can be mounted directly to a valve (attachment to rod-type yoke or according to NAMUR). e Air p Type 66 Pressure control The p/e converter measures the pressure in the pipeline and converts it to an electric signal. The controller uses the electric signal to calculate the control signal which is passed on by the positioner to finally close or open the pneumatic control valve. Type 324- e Type 634 p 6 T 6000 EN

7 Filling of liquids in the beverage industry and breweries The e/p converter converts an electric signal to a pneumatic signal. The pneumatic signal controls cylinders which insert filling tubes more or less deep, depending on the liquid level, into bottles, filling them with beverages or detergents. p e Air Type 626 To the PLC Booster control Boosters are used to amplify the flow rate of compressed air. To control boosters, you can use, apart from handwheels, also e/p converters which receive an electric signal from a controller or a PLC. Type 6 e Air p Applying. adhesive or glue Glue or adhesive is to be applied on different bases. Depending on the speed of the conveyor belt, varying quantities must be applied. The e/p converter receives an electric signal, which changes with the belt speed, and converts it to a pressure signal. The pressure causes the ball of a dispenser to adapt the outlet to the required amount of glue or adhesive. This ensures uniform application. Type 626 Air p e 7 T 6000 EN

8 Temperature control The SAMSON controllers TROVIS 642, 6493 and 6497 allow the realization of simple temperature control systems, e.g. flow temperature control in heating installations. The flow temperature is measured with a Pt 00 sensor and transmitted to the controller. The latter controls a pneumatic control valve by issuing an analog 4 to 20 ma signal via an i/p positioner. TROVIS 6493 TROVIS 6497 TROVIS 642 Mixing of two liquids TROVIS 642 can be used for ratio control when two liquids are mixed. The controller obtains signals from two differential pressure transmitters and root-extracts the signals. The controller then uses the signals to calculate an output signal for the control valve which must reach the required mixing ratio. PD TROVIS 642 F PD F Flow control TROVIS 642 and 6493 provide a convenient flow control. When using the root-extracting function of these controllers, the flow rate can be easily calculated from the differential pressure signal issued by the differential pressure transmitter. The analog output signal of the controller activates the positioner and with it the pneumatic valve. TROVIS 6493 TROVIS 642 PD F 8 T 6000 EN

9 Temperature control with function generation The SAMSON controllers TROVIS 642 and 6493 also allow the realization of a temperature control with function generation, e.g. an outdoor temperature-controlled flow temperature control. The outdoor temperature is measured with an Pt 00 sensor and passed on to the controller which utilizes function generation to directly convert the outdoor temperature to a set point for the flow temperature. The controller activates the electric control valve using a three-step signal. Temperature cascade control The boiler is heated by a heat exchanger. To minimize the delays of the controlled system, cascade control with a master and a slave controller is implemented. TROVIS 642 is particularly suited to solve this task since it is capable of being the master and the slave controller at the same time. It is also possible to use two TROVIS 6497 or two TROVIS 6493 controllers. The master controller measures the actual boiler temperature and forwards its manipulated variable as reference variable WE to the slave controller. The slave controller controls the flow temperature in the heat exchanger loop. The control valve is activated using a three-step signal. M x WE y x TROVIS TROVIS TROVIS 6493 Limiting control TROVIS 642 is also a good choice when performing limiting control with minimum selection, as shown in the example opposite. The color is to be heated to a certain predetermined temperature, however, the shell temperature of the reaction tank must not exceed the temperature of the color by a predetermined value. The reaction tank is heated or cooled down using two heat exchangers. The main controller controls the temperature of the color. The limiting controller controls the temperature difference between the tank shell temperature and the color temperature. The color temperature is applied to the analog output AA, fed back to the controller input as disturbance variable and subtracted from the shell temperature. The minimum selection function feeds the smaller control signal of both control loops to the split-range unit, thus activating both control valves. x y WE TROVIS 642 y AA 9 T 6000 EN

10 Explosion protection Some of the SAMSON e/p Converters are suitable for use in hazardous areas as they are frequently found in the chemical and petrochemical industry. Important factors of the explosion protection relevant for such applications are listed in the following. For details, please refer to the standards indicated. Zone classification Hazardous areas are grouped into zones to indicate the danger of explosion. Each zone prescribes particular measures which ensure explosion protection. Zone Meaning Example 0 2 Dangerous, potentially explosive atmospheres occur permanently or for a long time. Dangerous, potentially explosive atmospheres occur sometimes. Dangerous, potentially explosive atmospheres occur seldom and for a short time (< 2 h). Inside of reaction tanks containing flammable gases. In the proximity of Zone 0, immediate area around stuffing boxes that are not sufficiently sealed. Areas surrounding the Zones 0 and. Type of protection The type of protection describes the measures to be taken to prevent electrical appliances from igniting explosive atmospheres. Type of protection Basic principle Standard, regulation d Flameproof enclosure l Parts which can ignite an explosive atmosphere are placed in an enclosure which can withstand the pressure caused by an explosion inside the housing and prevents the transmission of the explosion to the surrounding explosive atmosphere. DIN EN VDE 070/07 Part 5 w Flameproof enclosures are suitable for Zones 0, and 2. i Intrinsic safety An electrical device is intrinsically safe when all circuits are intriniscally safe. A circuit is intrinsically safe when it does not R L produce sparks or thermal effects whose energy suffices to ignite an explosive atmosphere. U C DIN EN VDE 070/07 Part 7 Category ia Devices of this category are suitable for Zones 0, and 2. Zone 0 must be certified separately. Category ib Devices of this category are suitable for Zones and 2. Temperature classes The temperature classes group electrical appliances according to their max. permissible surface temperature. It must be smaller than the ignition temperature of the explosive material. Temperature class Maximum permissible surface temperature of the appliance Ignition temperature of the flammable material T 450 C > 450 C T2 300 C > C T3 200 C > C T4 35 C > C T5 00 C > C T6 85 C > C 0 T 6000 EN

11 UN 3 Ex Safety barriers according to DIN and EN Section 8 Safety barriers are passive networks which separate intrinsically safe and not intrinsically safe circuits without isolating them electrically. The output circuits of the safety barriers meet the requirements of the intrinsic safety ia and ib. Safety barriers are always installed outside the hazardous area. 2 4 /PA Circuit diagram of a safety barrier /PA IP Degree of protection The IP code characterizes an electrical appliance s protection against accidental contact and foreign particles as well as its protection against water. The code consists of two code numbers whose meanings are listed in the Table below. IP code IP 6 5 First code number (0 to 6) Prot. ag. contact and foreign particles Second code number (0 bis 8) Protection against water Code number Protection against accidental contact First code number Protection against foreign particles 0 None None None Protection against contact with the back of the hand Protection against contact with the finger Protection against contact with tools Protection against contact with a wire Protection against contact with a wire Protection against contact with a wire Protection against penetration of foreign particles >50mm Protection against penetration of foreign particles > 2.5 mm Protection against penetration of foreign particles > 2.5 mm Protection against penetration of foreign particles >.0 mm Protection against dust built-up which could impair the functioning of the device Dust-tight Protection against water Second code number Protection against water drops Protection against water drops when the device is tilted by up to 5 from the vertical position Protection against spray water hitting the device, at an angle of 60 from the vertical position Protection against spray water from all directions Protection against a water jet from all directions Protection against a strong water jet from all directions Protection against water when immersed under standardized time and pressure conditions Protection against water when permantently immersed under conditions which are agreed upon by the manufacturer and the customer. T 6000 EN

12 SAMSON AG MESS- UND REGELTECHNIK Weismüllerstraße Frankfurt am Main Germany Phone Fax Internet: T 6000 EN

Series 3730 Electropneumatic Positioner Type

Series 3730 Electropneumatic Positioner Type Series 3730 Electropneumatic Positioner Type 3730-0 Application Single-acting or double-acting positioner for attachment to pneumatic control valves Reference variable Travels 4 to 20 ma 5.3 to 200 mm

More information

Series 3730 Type Electropneumatic Positioner

Series 3730 Type Electropneumatic Positioner Series 3730 Type 3730-0 Electropneumatic Positioner Application Single-acting or double-acting positioner for attachment to pneumatic control valves Set point Travel 4 to 20 ma 5.3 to 200 mm The positioner

More information

PROFIBUS-PA Positioner Type 3785

PROFIBUS-PA Positioner Type 3785 PROFIBUS-PA Positioner Type 3785 Application Single-acting or double-acting PROFIBUS-PA positioner for attachment to pneumatic control valves. Rated travel from 7.5 to 120 mm Opening angle up to 120 Smart,

More information

Series 3731 Electropneumatic Ex d Positioner Type with FOUNDATION TM Fieldbus communication

Series 3731 Electropneumatic Ex d Positioner Type with FOUNDATION TM Fieldbus communication Series 3731 Electropneumatic Ex d Positioner Type 3731-5 with FOUNDATION TM Fieldbus communication Application Positioner for attachment to pneumatic control valves Travel: 3.6 to 200 mm Opening angle:

More information

Series 3730 Electropneumatic Positioner Type with PROFIBUS-PA communication

Series 3730 Electropneumatic Positioner Type with PROFIBUS-PA communication Series 3730 Electropneumatic Positioner Type 3730-4 with PROFIBUS-PA communication Application Positioner for attachment to pneumatic control valves Travels 3.6 to 200 mm Opening angle 24 to 100 Smart,

More information

Series 3730 Type Electropneumatic Positioner

Series 3730 Type Electropneumatic Positioner Series 3730 Type 3730- Electropneumatic Positioner Application Single-acting or double-acting positioner for attachment to pneumatic control valves. Self-calibrating, automatic adaptation to valve and

More information

Data Sheet T 8394 EN. Series 3725 Type 3725 Electropneumatic Positioner

Data Sheet T 8394 EN. Series 3725 Type 3725 Electropneumatic Positioner Data Sheet T 8394 EN Series 3725 Type 3725 Electropneumatic Positioner Application Single-acting positioner for attachment to pneumatic globe and rotary valves. Self-calibrating, automatic adaptation to

More information

Series 3731 TROVIS SAFE Electropneumatic Ex d Positioner

Series 3731 TROVIS SAFE Electropneumatic Ex d Positioner Series 3731 TROVIS SAFE 3731-3 Electropneumatic Ex d Positioner with HART communication Application Single-acting or double-acting Ex d positioner for attachment to pneumatic on/off valves in safety-instrumented

More information

Type 6150 AS-Interface Module. Type 3372 Electropneumatic Actuator with AS-interface module. Mounting and Operating Instructions EB 6150 EN

Type 6150 AS-Interface Module. Type 3372 Electropneumatic Actuator with AS-interface module. Mounting and Operating Instructions EB 6150 EN Type 6150 AS-Interface Module Type 3372 Electropneumatic Actuator with AS-interface module Mounting and Operating Instructions EB 6150 EN Edition July 2013 Definition of the signal words used in these

More information

Series 3731 Type Electropneumatic Ex d Positioner with HART communication

Series 3731 Type Electropneumatic Ex d Positioner with HART communication Series 3731 Type 3731-3 Electropneumatic Ex d Positioner with HART communication Application Single-acting or double-acting Ex d positioner for attachment to pneumatic control valves. Self-calibrating,

More information

Indicating Digital Transmitter for Differential Pressure and Flow. Media 6 with LCD Media 6 with LED

Indicating Digital Transmitter for Differential Pressure and Flow. Media 6 with LCD Media 6 with LED Indicating Digital Transmitter for Differential Pressure and Flow Media 6 with LCD Media 6 with LED Application Microprocessor-controlled transmitter for measuring and indicating the differential pressure

More information

Electropneumatic Positioner Type and Type with HART communication

Electropneumatic Positioner Type and Type with HART communication Electropneumatic Positioner Type 3730-2 and Type 3730-3 with HART communication Application Single-acting or double-acting positioner for attachment to pneumatic control valves. Self-adjusting, automatic

More information

Series 3731 Type Electropneumatic Ex d Positioner with FOUNDATION TM fieldbus communication

Series 3731 Type Electropneumatic Ex d Positioner with FOUNDATION TM fieldbus communication Series 3731 Type 3731-5 Electropneumatic Ex d Positioner with FOUNDATION TM fieldbus communication Application Positioners for attachment to pneumatic control valves Rated travels from 3.6 to 200 mm Opening

More information

Data Sheet T 6493 EN. TROVIS 6400 Automation System TROVIS 6493 Compact Controller. For panel mounting (front frame 48 x 96 mm/1.89 x 3.

Data Sheet T 6493 EN. TROVIS 6400 Automation System TROVIS 6493 Compact Controller. For panel mounting (front frame 48 x 96 mm/1.89 x 3. Data Sheet T 6493 EN TROVIS 6400 Automation System TROVIS 6493 Compact Controller For panel mounting (front frame 48 x 96 mm/1.89 x 3.78 inch) Application Digital controller to automate industrial and

More information

Series 3730 Electropneumatic Positioner Type with HART communication and pressure sensors

Series 3730 Electropneumatic Positioner Type with HART communication and pressure sensors Series 3730 Electropneumatic Positioner Type 3730-6 with HART communication and pressure sensors Application Single-acting or double-acting positioner for attachment to pneumatic control valves. Self-calibrating,

More information

T EN TROVIS Electropneumatic Positioner

T EN TROVIS Electropneumatic Positioner T 8484-1 EN TROVIS 3730-1 Electropneumatic Positioner Application Single-acting positioner for attachment to pneumatic globe and rotary valves. Self-calibrating, automatic adaptation to valve and actuator.

More information

Series 3730 Electropneumatic Positioner Type and Type with HART communication

Series 3730 Electropneumatic Positioner Type and Type with HART communication Series 3730 Electropneumatic Positioner Type 3730-2 and Type 3730-3 with HART communication Application Single-acting or double-acting positioner for attachment to pneumatic control valves. Self-calibrating,

More information

Digital Positioner 8049

Digital Positioner 8049 Compact digital positioner for pneumatic control valves. Positioner can be integrated into valve actuator (no external moving parts for stroke feedback) Wide range of strokes - 8 mm No steady-state air

More information

Series Electropneumatic Positioner Type and Type with HART communication

Series Electropneumatic Positioner Type and Type with HART communication Series 3730 Electropneumatic Positioner Type 3730-2 and Type 3730-3 with HART communication Application Single-acting or double-acting positioner for attachment to pneumatic control valves. Self-calibrating,

More information

Series 3730 Type Electropneumatic Positioner with PROFIBUS-PA communication

Series 3730 Type Electropneumatic Positioner with PROFIBUS-PA communication Series 3730 Type 3730-4 Electropneumatic Positioner with PROFIBUS-PA communication Application Positioners for attachment to pneumatic control valves Rated travels from 3.6 to 200 mm Opening angle 24 to

More information

Series 3730 Type Electropneumatic Positioner with PROFIBUS-PA communication

Series 3730 Type Electropneumatic Positioner with PROFIBUS-PA communication Series 3730 Type 3730-4 Electropneumatic Positioner with PROFIBUS-PA communication Application Positioners for attachment to pneumatic control valves Valve travel from 3.6 to 300 mm Opening angle 24 to

More information

Series 3793 TROVIS SAFE 3793 Electropneumatic Positioner with HART communication

Series 3793 TROVIS SAFE 3793 Electropneumatic Positioner with HART communication Series 3793 TROVIS SAFE 3793 Electropneumatic Positioner with HART communication Application Single-acting or double-acting positioner for attachment to pneumatic on/off valves in safety-instrumented systems.

More information

Series 3730 Type Electropneumatic Positioner

Series 3730 Type Electropneumatic Positioner Series 3730 Type 3730-2 Electropneumatic Positioner Application Single-acting or double-acting positioner for attachment to pneumatic control valves. Self-calibrating, automatic adaptation to valve and

More information

Data Sheet T 8493 EN. Series 3793 TROVIS 3793 Electropneumatic Positioner with HART communication

Data Sheet T 8493 EN. Series 3793 TROVIS 3793 Electropneumatic Positioner with HART communication Data Sheet T 8493 EN Series 3793 TROVIS 3793 Electropneumatic Positioner with HART communication Application Single-acting or double-acting positioner for attachment to pneumatic control valves. Self-calibrating,

More information

Series 3730 Electropneumatic Positioner Type and Type with HART communication

Series 3730 Electropneumatic Positioner Type and Type with HART communication Series 3730 Electropneumatic Positioner Type 3730-2 and Type 3730-3 with HART communication Application Single-acting or double-acting positioner for attachment to pneumatic control valves. Self-calibrating,

More information

TROVIS-VIEW software TROVIS 6661

TROVIS-VIEW software TROVIS 6661 TROVIS-VIEW software TROVIS 6661 Application Uniform interface for configuration and operation of various smart SAMSON devices TROVIS-VIEW provides a uniform user interface that allows users to configure

More information

Data Sheet T EN

Data Sheet T EN Data Sheet T 8384-4 EN Series 3730 Type 3730-4 Electropneumatic Positioner with PROFIBUS-PA communication Application Positioners for attachment to pneumatic control valves Valve travel from 3.6 to 300

More information

Series 3730 Type Electropneumatic Positioner with HART communication and pressure sensors

Series 3730 Type Electropneumatic Positioner with HART communication and pressure sensors Series 3730 Type 3730-6 Electropneumatic Positioner with HART communication and pressure sensors Application Single-acting or double-acting positioner for attachment to pneumatic control valves. Self-calibrating,

More information

INTRINSICALLY SAFE INSTRUMENTATION FOR HAZARDOUS AREAS

INTRINSICALLY SAFE INSTRUMENTATION FOR HAZARDOUS AREAS INTRINSICALLY SAFE INSTRUMENTATION FOR HAZARDOUS AREAS SHORT FORM 2002 SERIES D1000 Intrinsically Safe Galvanic Isolators SERIES D1000, for DIN Rail Mounting, provide the most simple and cost effective

More information

Electric Actuators Type 5824 (without fail-safe action) Type 5825 (with fail-safe action)

Electric Actuators Type 5824 (without fail-safe action) Type 5825 (with fail-safe action) Electric Actuators Type 5824 (without fail-safe action) Type 5825 (with fail-safe action) Application Electric actuators designed for valves used in heating, ventilation and air-conditioning systems as

More information

Series 3730 Type Electropneumatic Positioner with HART communication

Series 3730 Type Electropneumatic Positioner with HART communication Series 3730 Type 3730-3 Electropneumatic Positioner with HART communication Application Single-acting or double-acting positioner for attachment to pneumatic control valves. Self-calibrating, automatic

More information

SideControl Positioner

SideControl Positioner SideControl Positioner Electropneumatic positioner for pneumatically actuated process valves II (1) 2 G EEx ia IIC T6 approval can be combined with... Type 2712 Globe valve Globe valve acc. to NAMUR/IEC

More information

Data Sheet T EN

Data Sheet T EN Data Sheet T 8384-3 EN Series 3730 Type 3730-3 Electropneumatic Positioner with HART communication Application Single-acting or double-acting positioner for attachment to pneumatic control valves. Self-calibrating,

More information

3/2 Directional control valves Direct solenoid operated poppet valves Internal thread G 1/2, 1/2 NPT or flanged with NAMUR interface

3/2 Directional control valves Direct solenoid operated poppet valves Internal thread G 1/2, 1/2 NPT or flanged with NAMUR interface 9805 / Directional control valves Direct solenoid operated poppet valves Internal thread G /, / NPT or flanged with NAMUR interface Main application: single operated actuators for plants TÜV-approval based

More information

Pneumatic Control/Feedback

Pneumatic Control/Feedback 897 /Feedback Type 897 can be combined with... Compact design Integrated pilot valve with manual override Internal control air routing Bright LED position indicator Automatic end position adjustment Type

More information

INSTRUCTION MANUAL. Universal AC Input Switching Power Supply 24 Vdc Output DIN-Rail Models PSD1000, PSD1000F PSD PSD1000F

INSTRUCTION MANUAL. Universal AC Input Switching Power Supply 24 Vdc Output DIN-Rail Models PSD1000, PSD1000F PSD PSD1000F PSD1000 - PSD1000F INSTRUCTION MANUAL Universal AC Input Switching Power Supply 24 Vdc Output DIN-Rail Models PSD1000, PSD1000F PSD1000 - Universal AC Input Switching Power Supply 24 Vdc Output ISM0089-4

More information

HERION SERIES Indirect solenoid actuated spool valves

HERION SERIES Indirect solenoid actuated spool valves HERION SERIES Indirect solenoid actuated spool valves for single and double acting actuators with NAMUR interface /2, /2, /, NC/APB, G/, G/2 Valves for safety systems up to SIL (IEC 08) Crossover-free

More information

PHOENIX CONTACT - 05/2007

PHOENIX CONTACT - 05/2007 Ex Universal Module Carrier (Motherboard) for Accommodating 3-Wire Measuring Transducers, Intrinsically Safe, for a Maximum of 8 PI Ex Modules INTERFACE Data Sheet 103030_00_en PHOENIX CONTACT - 05/2007

More information

Pneumatic Control/Feedback

Pneumatic Control/Feedback 897 /Feedback Type 897 can be combined with... Compact design Integrated pilot valve with manual override Internal control air routing Automatic end position adjustment With ATEX II cat. G/D and cat. D/G

More information

Everything under control

Everything under control SAMSON Everything under control SAMSON building automation Ready-configured user interfaces support the user during start-up as well as provide powerful features to control and monitor building facilities.

More information

HMT360 Series Intrinsically Safe Humidity and Temperature Transmitters

HMT360 Series Intrinsically Safe Humidity and Temperature Transmitters HMT360 Series Intrinsically Safe Humidity and Temperature Transmitters For operation in up to Zone 0 / 20 Features Measures humidity and temperature, outputs also dew point, mixing ratio, absolute humidity

More information

Operating Instructions. Intrinsically Safe Isolation Relay for Switches Model: REL manual_rel-6_0505

Operating Instructions. Intrinsically Safe Isolation Relay for Switches Model: REL manual_rel-6_0505 Operating Instructions Intrinsically Safe Isolation Relay for Switches Model: REL-6003 manual_rel-6_0505 1. Contents 1. Contents...2 2. Note...3 3. Instrument Inspection...3 4. Regulation Use...3 5. Operating

More information

Pneumatic Control/Feedback

Pneumatic Control/Feedback 897 /Feedback Type 897 can be combined with... Compact design Integrated pilot valve with manual override Internal control air routing Bright LED position indicator Automatic end position adjustment Type

More information

Safety Barriers. CEAG safety barriers can be used for all kinds of instrumentation applications.

Safety Barriers. CEAG safety barriers can be used for all kinds of instrumentation applications. Safety Barriers Description Safety barriers limit the energy fed to an intrinsically safe circuit so that neither sparks nor thermal effects (hot surfaces) can cause an explosion. CEAG safety barriers

More information

Digital electropneumatic Positioner for the integrated mounting on process control valves

Digital electropneumatic Positioner for the integrated mounting on process control valves Digital electropneumatic Positioner for the integd mounting on process control valves Type 8692 can be combined with Compact stainless steel design Graphic display with backlight Easy start-up by automatic

More information

Material pressure (bar) (Cv (US) kv x 1,2 Seat

Material pressure (bar) (Cv (US) kv x 1,2 Seat 00 / poppet valves electromagnetic actuated, directly controlled G /, / NPT or flanged with NAMUR Interface TÜV-approval based on IEC 6 08, DIN V Valves for safety systems up to SIL Solenoid valve also

More information

3/2 Directional control valves Indirect controlled solenoid operated poppet valves Internal thread G1/2, 1/2 NPT or flanged with NAMUR interface

3/2 Directional control valves Indirect controlled solenoid operated poppet valves Internal thread G1/2, 1/2 NPT or flanged with NAMUR interface 9805 / Directional control valves Indirect controlled solenoid operated poppet valves Internal thread G/, / NPT or flanged with NMUR interface Main application: single operated process actuators TÜV-approval

More information

Compact Universal Controllers

Compact Universal Controllers 7 865 ISO9001 RWF40... complete with housing Compact Universal Controllers RWF40... The RWF40... is a universal digital boiler temperature / pressure controller with functions designed specifically for

More information

TRANSMITTERS. HygroFlex & HygroClip-EX. Applications. Highlights

TRANSMITTERS. HygroFlex & HygroClip-EX. Applications. Highlights HygroFlex & HygroClip-EX HygroFlex series may be used together with the intrinsically safe HygroClip-EX probes. The relative humidity and temperature can be displayed and output as analog signals. Calculated

More information

TURCK Process Automation IS Interface Technology. Interface Modules. IM Series Cabinet

TURCK Process Automation IS Interface Technology. Interface Modules. IM Series Cabinet Process Automation IS Interface Technology Interface Modules TURCK's IM series of Isolating Intrinsically Safe Barriers is designed to be a simple and safe way to solve the problems associated with the

More information

97105 Inline 3/2, 5/2 & 5/3 way spool valves electromagnetic actuated, indirectly controlled G1/4, 1/4 NPT, G1/2, 1/2 NPT

97105 Inline 3/2, 5/2 & 5/3 way spool valves electromagnetic actuated, indirectly controlled G1/4, 1/4 NPT, G1/2, 1/2 NPT 70 Inline 3/, / & /3 way spool valves electromagnetic actuated, indirectly controlled G/, / NPT, G/, / NPT Main application: single and double operated actuators TÜV-approval based on type examination

More information

General. Remote I/O A4/1.

General. Remote I/O A4/1. www.stahl.de > Intrinsically safe Ex ia IIC, Ex e, Ex na or Ex nl inputs and outputs > Fieldbus communication: Modbus RTU, Profibus DP V0 and DP V1 HART, Industrial Ethernet, Modbus TCP, EtherNet/IP, PROFINET

More information

Digital electropneumatic Positioner SideControl

Digital electropneumatic Positioner SideControl Digital electropneumatic Positioner SideControl Type 8791 BASIC can be combined with Compact and robust design Easy to start using tune function Dynamic positioning system with no air consumption in controlled

More information

INSTRUCTION MANUAL. SIL 3 Relay Output Module DIN-Rail Models D1092S-069, D1092D-069 D1092S D1092D-069

INSTRUCTION MANUAL. SIL 3 Relay Output Module DIN-Rail Models D1092S-069, D1092D-069 D1092S D1092D-069 D09S09 D09D09 INSTRUCTION MANUAL SIL Relay Output Module DINRail Models D09S09, D09D09 D0909 SIL Relay Output Module ISM00 SIL Applications For Safety Related System and SIL, SIL Applications according

More information

Automation System TROVIS 5400 District Heating Controller TROVIS 5476

Automation System TROVIS 5400 District Heating Controller TROVIS 5476 Automation System TROVIS 5400 District Heating Controller TROVIS 5476 On-off or three-step controller designed for wall or panel mounting (dimensions of front frame: 44 mm x 96 mm) Application Self-optimizing,

More information

97105 Inline 3/2, 5/2 & 5/3 spool valves electromagnetic actuated, indirectly controlled G 1/4, 1/4 NPT, G 1/2, 1/2 NPT

97105 Inline 3/2, 5/2 & 5/3 spool valves electromagnetic actuated, indirectly controlled G 1/4, 1/4 NPT, G 1/2, 1/2 NPT 705 Inline 3/, 5/ & 5/3 spool valves electromagnetic actuated, indirectly controlled G /, / NPT, G /, / NPT For single and double operated actuators Valves for safety systems up to SIL (IEC 6508) Crossover-free

More information

97105 NAMUR. Technical data. Ordering information and accessories See page 6 and 7

97105 NAMUR. Technical data. Ordering information and accessories See page 6 and 7 90 NAMUR /, / and / directional valves Actuation: electromagnetic Indirectly controlled soft seal spool valves Port size: G /, / NPT, G /, / NPT NAMUR-interface For single and double operated actuators

More information

Application The DA03 serves as indicator of differential. Follow mounting instructions in accordance to application.

Application The DA03 serves as indicator of differential. Follow mounting instructions in accordance to application. DA03 Differential Pressure Gauge / Differential Pressure Gauge and Switch Models for Assignment in Explosion-hazardous Areas per Directive 94/9/EC (ATEX) Application The DA03 serves as indicator of differential

More information

Signal processor MS96 for flow sensors MS96-11EX0-R/230VAC

Signal processor MS96 for flow sensors MS96-11EX0-R/230VAC MS96-11EX0-R/230VAC ATEX category II (1) G, Ex Zone 0 ATEX category II (1) D, Ex Zone 20 single-channel signal processor MS96 for connection of an intrinsically safe flow control sensor in zone 0 adjustment

More information

S900 Remote I/O System Intrinsic safety in the field ABB

S900 Remote I/O System Intrinsic safety in the field ABB S900 Remote I/O System Intrinsic safety in the field ABB 2 S900 REMOTE I/O SYSTEM INTRINSIC SAFETY IN THE FIELD The S900 Remote I/O System 01 Example of Field housing FH660S in stainless steel with complete

More information

APPLICATION GUIDE. Interface Modules IM Series.

APPLICATION GUIDE. Interface Modules IM Series. Interface Modules IM Series APPLICATION GUIDE www.turck.com Interface Technology Interface Modules TURCK's IM series of Isolating Intrinsically Safe Barriers is designed to be a simple and safe way to

More information

PI-EX-ME-2NAM/COC-120VAC

PI-EX-ME-2NAM/COC-120VAC PI-EX-ME-NAM/COC-0VAC Ex-i NAMUR Isolation Amplifier, With Intrinsically Safe Input and Relay Output, PDT, Two-Channel, 0 V AC Supply INTERFACE Data Sheet 0944_00_en PHOENIX CONTACT - 0/008 Description

More information

HMT360 Series Intrinsically Safe Humidity and Temperature Transmitters

HMT360 Series Intrinsically Safe Humidity and Temperature Transmitters www.vaisala.com HMT360 Series Intrinsically Safe Humidity and Temperature Transmitters Customers may specify the transmitter configuration when ordering the instrument, however changes in configuration

More information

Refer to attachment for more details. Andreas Meyer

Refer to attachment for more details. Andreas Meyer IECEx Certificate of Conformity INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com Certificate No.:

More information

WAGO-I/O-SYSTEM. Fieldbus Technology. for Use in Hazardous Areas

WAGO-I/O-SYSTEM. Fieldbus Technology. for Use in Hazardous Areas WAGO-I/O-SYSTEM Fieldbus Technology for Use in Hazardous Areas For Use in Hazardous Areas The WAGO-I/O-SYSTEM 0 is a modular, fi eldbus-independent I/O system for decentralized automation. This system,

More information

HMT360 Series Intrinsically Safe Humidity and Temperature Transmitters

HMT360 Series Intrinsically Safe Humidity and Temperature Transmitters www.vaisala.com HMT360 Series Intrinsically Safe Humidity and Temperature Transmitters Customers may specify the transmitter configuration when ordering the instrument, however changes in configuration

More information

Float Switches with Permanent Magnet For Vertical Installation Model RSM

Float Switches with Permanent Magnet For Vertical Installation Model RSM Level Measurement Float Switches with Permanent Magnet For Vertical Installation Model RSM WIKA Data Sheet LM 30.01 Applications Level measurement for almost all liquid media Pump/level control and monitoring

More information

ADAMCZEWSKI. Ordering data AD-STVEX 710 GVD Option: Factory-software configuration as per customer specifications.

ADAMCZEWSKI. Ordering data AD-STVEX 710 GVD Option: Factory-software configuration as per customer specifications. EN ADAMCZEWSKI Elektronische Messtechnik GmbH Felix-Wankel-Str. 13 / 74374 Zaberfeld Tel. +49 (0)7046-875 Fax +49 (0)7046-7678 vertrieb@ad-messtechnik.de Operating Instructions Supply Isolation Amplifier

More information

Reed sensor For bypass level indicators Model BLR

Reed sensor For bypass level indicators Model BLR Level measurement Reed sensor For bypass level indicators Model BLR WIKA data sheet LM 10.04 for further approvals see page 3 Applications Sensor for the continuous level measurement of liquids in bypass

More information

Intrinsically Safe Barriers

Intrinsically Safe Barriers Intrinsically Safe Barriers Description Page No. Safety Barriers 464-472 Din Rail Isolated Barriers 473-488 477 Intrinsically Safe Barriers Product Overview We have simplified intrinsic safety! Cooper

More information

Safety instructions Overvoltage protection B81-35

Safety instructions Overvoltage protection B81-35 Safety instructions Overvoltage protection B81-35 IECEx BVS 15.0084X Intrinsic safety Document ID: 51001 Contents 1 Area of applicability... 3 2 General information... 3 3 Technical data... 5 4 Application

More information

Digital electropneumatic positioner

Digital electropneumatic positioner Digital electropneumatic positioner Type 879 can be combined with Compact metal housing Graphic display with backlight Easy start-up Comprehensive range of additional software functions Profibus DPV1 (optional)

More information

MODEL: 6DV-B. [2] TERMINAL BLOCK 0: None (Euro terminal block at the rear of indicator module)

MODEL: 6DV-B. [2] TERMINAL BLOCK 0: None (Euro terminal block at the rear of indicator module) Field-mounted Two-wire Signal Conditioners 6-UNIT -DIGIT LOOP POWERED INDICATOR (outdoor enclosure, intrinsically safe/explosion-proof) Functions & Features -digit LED display No external power source

More information

Dual Module VCT. 5. Lexan Enclosure is Water & Corrosion Proof Contaminants will not affect the module as long as terminal strip is not immersed.

Dual Module VCT. 5. Lexan Enclosure is Water & Corrosion Proof Contaminants will not affect the module as long as terminal strip is not immersed. 2 The integrates position sensing, communication electronics, power outputs, auxiliary inputs and wire termination into a fully sealed compact package. The module also integrates a terminal strip directly

More information

MODEL: 6DV-B. [2] TERMINAL BLOCK 0: None (Euro terminal block at the rear of indicator module)

MODEL: 6DV-B. [2] TERMINAL BLOCK 0: None (Euro terminal block at the rear of indicator module) Field-mounted Two-wire Signal Conditioners 6-UNIT -DIGIT LOOP POWERED INDICATOR (outdoor enclosure, intrinsically safe/explosion-proof) Functions & Features -digit LED display No external power source

More information

Digital electropneumatic Positioner for the integrated mounting on process control valves

Digital electropneumatic Positioner for the integrated mounting on process control valves Digital electropneumatic Positioner for the integrated mounting on process control valves Type 8696 can be combined with Digital smart positioner Automatic teach function Contact-free position sensor Compact

More information

Digital electropneumatic positioner

Digital electropneumatic positioner Digital electropneumatic positioner Type 879 can be combined with Compact metal housing Graphic display with backlight Easy start-up Comprehensive range of additional software functions Profibus DPV1 (optional)

More information

PI-EX-ME-2NAM/COC-24VDC

PI-EX-ME-2NAM/COC-24VDC Ex-i NAMUR Isolation Amplifier, With Intrinsically Safe Input and Relay Output, PDT, Two-Channel, 4 V DC Supply INTERFACE Data Sheet 0033_0_en PHOENIX CONTACT - /007 Description The PI-EX-ME-NAM/COC-4VDC

More information

INTRINSICALLY SAFE ACOUSTIC EMISSION TRANSDUCERS

INTRINSICALLY SAFE ACOUSTIC EMISSION TRANSDUCERS Abstract INTRINSICALLY SAFE ACOUSTIC EMISSION TRANSDUCERS RAN ZHOU and STAN HALE Score Atlanta Inc., 975 Cobb Place Blvd. Suite 202, Kennesaw GA, 30144 Intrinsic safety (IS) is a signaling technique that

More information

Series 430 Type 3430 Pneumatic Indicating Controllers. Equipment for Pressure Temperature Standard Signals

Series 430 Type 3430 Pneumatic Indicating Controllers. Equipment for Pressure Temperature Standard Signals Series 430 pe 3430 Pneumatic Indicating Controllers Equipment for Pressure emperature Standard Signals Associated Data Sheets 703 EN to 7045 EN Edition October 00 Information Sheet 7030 EN Series 430 Pneumatic

More information

Data sheet deltwavec-f

Data sheet deltwavec-f deltawavec vec-f Data sheet deltwavec-f 1- Channel, 2- Channel, Ex Ultrasonic clamp-on flowmeter for liquids Lindberghstrasse 4, 82178 Puchheim Telefon 089-80906-0, Telefax 089-80906-200 http://www.systec-controls.de

More information

SYSTEM COMPONENTS SYSTEM COMPONENTS MODULES

SYSTEM COMPONENTS SYSTEM COMPONENTS MODULES SYSTEM COMPONENTS SYSTEM COMPONENTS MODULES O U R P R O F E S S I O N MULTIFUNCTIONAL CURRENT CONTROLLED SWITCH MODULES MAIN FEATURES 4 20 ma input Relay output Rail mountable Intrinsically safe Associated

More information

Dräger Polytron IR. Dräger Polytron IR: Configurable gas detector for reliable detection of combustible gases and vapours.

Dräger Polytron IR. Dräger Polytron IR: Configurable gas detector for reliable detection of combustible gases and vapours. DETECTION PERSONAL PROTECTION DIVING TECHNOLOGY SYSTEM TECHNOLOGY SERVICES Dräger Polytron IR ST-3949-2004 The Dräger Polytron IR is an explosion proof infrared gas detector for continuous monitoring of

More information

Operating instructions (Safety-related part ATEX and IECEx) Inductive NAMUR sensors NN504A NN505A NN506A NN507A /00 08/2015

Operating instructions (Safety-related part ATEX and IECEx) Inductive NAMUR sensors NN504A NN505A NN506A NN507A /00 08/2015 Operating instructions (Safety-related part ATEX and IECEx) Inductive NAMUR sensors NN504A NN505A NN506A NN507A 80013497/00 08/015 Remarks for safe use in hazardous areas Functions and features Use in

More information

T 9510 EN Media 7 Differential Pressure Meter with remote data transmission

T 9510 EN Media 7 Differential Pressure Meter with remote data transmission T 9510 EN Media 7 Differential Pressure Meter with remote data transmission Application Microprocessor-controlled transmitter with dp cell for measuring and indicating the differential pressure, pressure,

More information

Digital electropneumatic Positioner for the integrated mounting on process control valves

Digital electropneumatic Positioner for the integrated mounting on process control valves Digital electropneumatic Positioner for the integrated mounting on process s Type 8694 can be combined with Automatic teach function Contact-free position sensor Compact stainless steel design AS-Interface

More information

IHP24. Intelligent Hydraulic Positioner D HP- PL

IHP24. Intelligent Hydraulic Positioner D HP- PL IHP24 Intelligent Hydraulic Positioner D HP- PL- 0 0 3-01 IHP24 Intelligent Hydraulic Positioner Val Controls A/S Intelligent valve control based on the latest know-how concerning digital technology for

More information

Float Switches with Permanent Magnet For Horizontal Installation Model HIF

Float Switches with Permanent Magnet For Horizontal Installation Model HIF Level Measurement Float Switches with Permanent Magnet For Horizontal Installation Model HIF WIKA Data Sheet LM 30.02 Applications Level measurement for almost all liquid media Pump/level control Chemical

More information

technical datasheet technical datasheet MTL660 Displays Loop-powered indicators for hazardous areas

technical datasheet technical datasheet MTL660 Displays Loop-powered indicators for hazardous areas technical datasheet technical datasheet MTL0 Displays Loop-powered indicators for hazardous areas Loop powered -0mA Field and panel mounting Environmental protection to IP7 Easy to configure Number of

More information

About the FLEX Ex I/O Systems

About the FLEX Ex I/O Systems Section 2.1 About the FLEX Ex I/O Systems 1797 FLEX Ex I/O Overview FLEX Ex I/O offer: Adapter Terminal base I/O module Bus connectors Keyswitch FlexBus connectors 24V DC field power Terminal strips FLEX

More information

PHOENIX CONTACT - 12/2007

PHOENIX CONTACT - 12/2007 Ex-i NAMUR Isolation Amplifier, With Intrinsically Safe Input and Active Transistor Output, Two-Channel INTERFACE Data Sheet 0943_00_en PHOENIX CONTACT - /007 Description The PI-EX-ME-NAM/TO-A is a two-channel

More information

Installation & Operation Manual

Installation & Operation Manual Via Enrico Fermi, 2 I-25015 Desenzano del Garda (BS) - Italy Phone: +39 030 7870787 Fax: +39 030 7870777 www.solexy.net BAF Intrinsically Safe Ethernet Coupler for signals operating in Hazardous Areas

More information

Operating pressure (bar)

Operating pressure (bar) / poppet valves electromagnetic actuated, directly controlled G /4, /4 NPT, G /, / NPT or flanged with NAMUR Interface Main application: single operated actuators for plants Valves for safety systems up

More information

Technical features. N/en

Technical features. N/en /, 5/ & 5/ spool valves electromagnetic actuated, indirectly controlled G /, / NPT, G /, / NPT or flanged with NAMUR interface For single and double operated actuators Exhaust air recirculation at way

More information

VALVES Inline 3/2-, 5/2- & 5/3 Spool valves electromagnetic actuated, indirectly controlled G 1/4, 1/4 NPT, G 1/2, 1/2 NPT

VALVES Inline 3/2-, 5/2- & 5/3 Spool valves electromagnetic actuated, indirectly controlled G 1/4, 1/4 NPT, G 1/2, 1/2 NPT 975 Inline 3/-, 5/- & 5/3 Spool valves electromagnetic actuated, indirectly controlled G /, / NPT, G /, / NPT For single and double operated actuators Closed crossover design Add-on manual override Rectified

More information

Operating Instructions

Operating Instructions Operating Instructions t i SPAN NOT USED - - 4...20mA DISPLAY t i SPAN END POINT DISPLAY Ð - 4...20mA p Safety information, Note Ex area Safety information Please read this manual carefully, and also take

More information

Thermocouples Model TC200, for Additional Thermowell

Thermocouples Model TC200, for Additional Thermowell Electrical Temperature Measurement Thermocouples Model TC200, for Additional Thermowell WIKA Data Sheet TE 65.10 Applications T Machinery, plant and tank construction T Energy and power plant technology

More information

Technical Data. General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm. Short-circuit protection

Technical Data. General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm. Short-circuit protection NCN-FK-N-V-V 002 Model Number NCN-FK-N-V-V Features Direct mounting on standard actuators Compact and stable housing with terminal compartment connection Fixed setting EC-Type Examination Certificate TÜV99

More information

Safety instructions. IECEx TUN Ex ia IIC T6 Gb

Safety instructions. IECEx TUN Ex ia IIC T6 Gb Safety instructions ÜSB62-36G.C_* and ÜSB62-30W.C_* IECEx TUN 07.0002 Ex [ia Ga] IIC T6 Gb Ex ia IIC T6 Gb 0044 39878 Content 1 Area of applicability 3 2 General 3 3 Electrical data 3 3.1 Application conditions

More information

Level gauges Series LS Level indicator, switch and transmitter for liquids

Level gauges Series LS Level indicator, switch and transmitter for liquids Level gauges Series LS Level indicator, switch and transmitter for liquids Simple construction Resistant under extreme temperature and pressure conditions No risk of leakage Measuring range: from 150 mm

More information