Contents 1 Warnings, Cautions, and Notes Description Features... 1

Size: px
Start display at page:

Download "Contents 1 Warnings, Cautions, and Notes Description Features... 1"

Transcription

1 EnCell

2 Contents 1 Warnings, Cautions, and Notes Description Features STANDARD FEATURES FRONT PANEL FEATURES Display OK LED FAULT LED Push Button Controls Cell Voltage Sense Input DC Input Output Relay BOTTOM PANEL FEATURES RS485 Port Temp Sense Ethernet Operation FRONT PANEL DISPLAY AND PUSH BUTTON CONTROLS Installation MOUNTING Wall Mount EXTERNAL WIRING CONNECTIONS TO BATTERY CELLS INPUT POWER CONNECTIONS TEMPERATURE SENSOR INPUT WAGO WIRE SIZE REQUIREMENTS Basic Setup Procedure MENU CONTROL AND ADJUSTMENTS: STATUS BASIC ADVANCED FAULT HISTORY MENU SETPOINTS MENU BASIC SET POINTS ADVANCED SET POINTS CELL MONITOR MENU BATTERY TESTING STATUS FACTORY DEFAULTS RSM-SUB MONITOR FRONT PANEL FEATURES Cell Voltage Sense Input RSM-SUB MONITOR BOTTOM PANEL FEATURES Dual RS 485 Ports Hosted web page LOGIN STATUS PAGE SETTINGS Specifications... 20

3 List of Tables Table 1. Warnings, Cautions, and Notes... 1 Table 2. FAULT LED States... 3 Table 3. Current Sensor Configurations Table 4. General Specifications Table 5. Model Specifications List of Figures Figure 1. Front of Battery Cell Monitor... 2 Figure 2. Bottom of Battery Cell Monitor... 4 Figure 3. Push Button Controls... 5 Figure 4. System Status Figure 5. Settings - Cell Monitoring Figure 6. Wiring Diagrams for EnCell RCM Sub Monitor and Main Monitor... 21

4 1 WARNINGS, CAUTIONS, AND NOTES Please read the entire instruction manual before using the battery cell monitor. Also, read the warnings, cautions, and notes in Table 1. Failure to observe the warnings and cautions can lead to equipment damage or personal injury. If you have any questions concerning the manufacture, design, function, installation, operation or maintenance, contact EnCharge Power Systems before proceeding. Symbol Table 1. Warnings, Cautions, and Notes Description WARNING indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury. CAUTION indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate personal injury. It may also be used to alert against unsafe practices. NOTE NOTE indicates explanatory information that applies to the next step in the procedure. It is used to clarify and expand upon the importance of the procedural step when needed. 2 DESCRIPTION The EnCell RCM Multiple Cell Monitor is capable of monitoring 15 battery voltages at one time with a maximum string voltage of 225VDC. The EnCell RCM Multiple Cell Monitor has an input voltage range of 10-30VDC to power it. It has an operating temperature range of -40 F to +158 F (-40 C to 70 C) allowing it to work effectively in many environments. A set of contacts are provided for monitoring High and Low Battery Voltage, Current and Temperature. User defined alarms can be easily set. 3 FEATURES 3.1 Standard Features Monitors voltage and current (with current sensor) of batteries/cells Monitors temperature (with thermal sensor) of batteries/cells If monitored parameter is outside a predetermined level a notification can be sent to alert appropriate personnel Operates on minimal power from the battery bank Ethernet, relay output and RS485 to accommodate a variety of inputs and outputs Easy to read 4 x 20 Character display Ethernet Port for monitoring and configuration. Dual Form C Dry Contact fused 2 Amp Relay Output Records data when connected to EnVision Remote Monitoring AC & DC Circuit Transient Protection NERC PRC-005 Compliant 2018 EnCharge Power Systems PAGE 1

5 3.2 Front Panel Features Push Button Controls Display Status LED s 15 Cell Voltage Sense Input (Red) DC Input Dual Output Relays Figure 1. Front of Battery Cell Monitor Display The display is a 4 x 20 character OLED display. It enters sleep mode after inactivity to extend the life of the display. To wake the display, press any control button OK LED The OK LED is on when the DC Output Voltage is between the HIGH VOLTAGE FAULT and LOW VOLTAGE FAULT settings (see section for configuration) FAULT LED The FAULT LED has three different states, OFF, ON and FLASH. In addition to the FAULT LED, the display will show fault description. The fault conditions are described in the table below EnCharge Power Systems PAGE 2

6 Table 2. FAULT LED States Description FAULT LED (Red) No Fault OFF Battery Temperature Fault ON Battery Current Fault ON Battery Voltage Fault ON Push Button Controls The push button controls have mode left / mode right / increase / decrease. See section 4 and section 7 for operations and menu options Cell Voltage Sense Input The EnCell RCM Cell Monitor s (16) position WAGO terminal connector is used to connect the red voltage sense wires from the monitor to the battery bank DC Input The EnCell RCM Cell Monitor is powered by a 10-30VDC source. (A power supply with a minimum of 2 Amps is required to power the Main Monitor and Sub Monitors (RSM)) WARNING: It is advised to take extreme caution when dealing with high DC voltages. If precautions are not taken, injury or even death can result Output Relay The voltage monitor provides a Form C dry contact relay which can be used to indicate when the battery voltage, current and temperature are either above or below the parameter settings. The normally open contact is closed when the battery voltage, current and temperature is between the high and low settings. The relay is rated for 2 Amps at 60 VDC, or 2 Amps at resistive loads. The mechanical contact life is 5,000,000 operations. Minimum inductive Amps, 12vdc is 50,000 times. The battery monitor can be connected to external alarm mechanisms (i.e. strobe light, alarm bell, buzzer, etc.) via the contact relay (output 1). Output 2 can be configured for customer needs. The voltage monitor relay is protected with a 2 Amp, 32 VDC, fast acting mini fuse (use Littelfuse part number or equivalent) EnCharge Power Systems PAGE 3

7 3.3 Bottom Panel Features Temp Sense Ethernet Port RS485 Port Figure 2. Bottom of Battery Cell Monitor RS485 Port The RS485 is used to connect and provide power to sub-monitors or other assets Temp Sense The RTD Temperature Sensor is used to monitor the cell temperature. The probe end can be placed between battery cells to accurately monitor battery temperature. (Compatible with a 1K RTD) Ethernet This RJ45 Ethernet connection is used for accessing the monitor, either via its internal webpage or via the Remote Monitoring Server EnCharge Power Systems PAGE 4

8 4 OPERATION 4.1 Front Panel Display and Push Button Controls The front panel has the (4) line display, status LED display and four control buttons. The display will auto dim after several minutes of inactivity. Once a button is pressed the display will return to full brightness. SET-UP AND ADJUSTMENTS: To change settings, do the following: SWITCH VOLTAGE 12.6V RTD TEMP 76 F Figure 3. Push Button Controls MODE LEFT/MODE RIGHT Pushing the MODE UP or MODE DOWN push button will cycle up or down through the menus. Each time you press one of the MODE buttons, you will advance one menu selection. VALUE INCREASE/VALUE DECREASE The VALUES INCREASE and DECREASE push button allows you to change the displayed values. NOTE: Values that are changed will be saved after 15 minutes, or when you return to the status screen EnCharge Power Systems PAGE 5

9 5 INSTALLATION WARNING: It is advised to take extreme caution when dealing with high DC voltages. If precautions are not taken, injury or even death can result. NOTE: The term Highest refers to the battery cell with the highest potential. The term Lowest refers to the battery cell with the lowest potential. NOTE: The Voltage Sense and Negative Voltage Sense Wires should be connected closest to the battery terminals. 5.1 Mounting Wall Mount Use the two-four keyed slots on the back of the monitor for mounting to a wall. 5.2 External Wiring Connections to Battery Cells The EnCell RCM Multiple Cell Monitor s (16) position WAGO terminal connector is labeled Starting at 1, connect the positive wire of the highest battery cell to the cell monitor, and then connect the next highest positive battery cell to 2, and then connect the next highest positive battery cell to 3 and so on until you have hooked up all the positive battery terminals. You will then need to hook the negative wire from the lowest cell to the position next to the lowest positive cell. EX if you had 10 cells you would need to hook the negative wire to position 11, and if you had 15 cell you would need to hook it to position 16. The Split Core Current Coils should be connected to the monitor using a standard Ethernet cable. Plug one end of the first cable into the RS485 port on the monitor and connect the other end to the first current coil. Connect the second current coil using a second Ethernet cable (See Appendix A for battery wiring) 5.3 Input Power Connections Connect the negative wire to the (2) position WAGO terminal labeled Com 0V. Connect the positive wire to the (2) position WAGO terminal connector labeled VDC. (A power supply with a minimum of 2 Amps is required to power the Main Monitor and Sub Monitors) 5.4 Temperature Sensor Input Connect the (2) pin header to the Temp Sense input on the monitor and place the other end between the two middle cells. (Compatible with a 1K RTD) 2018 EnCharge Power Systems PAGE 6

10 5.5 WAGO Wire Size Requirements The minimum wire size compatible with the WAGO Terminal Block is 18GA and the maximum is 16GA. 6 BASIC SETUP PROCEDURE To initially set up the EnCell RCM Monitor, use the INCREASE/DECREASE buttons to move between MENUs, the MODE buttons to navigate between screens, and INCREASE/DECREASE buttons to change parameter values. Go to the SET POINTS menu. Set the PASSWORD to 5. Leave USER LEVEL at BASIC. Select BATTERY TYPE (LEAD ACID or NI-CAD) Set NUMBER OF CELLS per your battery bank. Set VOLTS PER CELL to battery manufacturers specs. The battery cell monitor should be ready to operate. 7 MENU CONTROL AND ADJUSTMENTS: Controller Menu The controller has 5 Menu Screens: 1. STATUS 2. FAULT HISTORY 3. SET POINTS 4. FACTORY DEFAULTS 5. CELL MONITOR Menu Screen Selection: To select the desired Menu Screen, press the MODE LEFT or RIGHT button until **** MENU SELECT **** is displayed, on line 1, and then use the INCREASE or DECREASE Value button to select the appropriate menu. Once the appropriate menu is selected, use the MODE LEFT or RIGHT buttons to view the contents of the menu. NOTE: Use the Increase or Decrease buttons to change set point values. 7.1 STATUS The STATUS Screen can display BASIC or ADVANCED information based on what the USER LEVEL is set to EnCharge Power Systems PAGE 7

11 TOTAL VOLTAGE 10.8V LOAD 0.0A BAT 0.0A SOC 0 ERT 0.0 RTD TEMP 76F BASIC TOTAL VOLTAGE Displays the total voltage for the entire battery string. This includes battery cells connected to a slave device. LOAD CURRENT Displays the load current of the battery string. BATTERY CURRENT Displays the battery current of the entire string. STATE OF CHARGE Indicates the level of charge that the battery string has. ESTIMATED RUN TIME Indicates the duration of the battery string s charge based on load data. This duration is measured in Amp-hours. RTD TEMP Displays the temperature measured by the RTD if a temperature probe is installed. If there is not a temperature probe installed, this field will be blank. CELL 1-9 VOLTAGES CELL VOLTAGE This displays the voltage reading of the individual cells by the Main Monitor and all Sub Monitor(s), if installed. A total of 9 cells are viewable at a time. If there are more than 9 individual battery cells, press the INCREASE button to view the remaining cells EnCharge Power Systems PAGE 8

12 7.1.2 ADVANCED OUTPUT POWER TOTAL: RESETTABLE: 0.0kWh 0.0kWh TOTAL OUTPUT POWER Shows the total output power of the battery string. RESETTABLE TOTAL OUTPUT POWER This is a resettable display of the total output power. HOUR METER TOTAL: 0.0 RESETTABLE: 0.0 TOTAL HOUR METER This displays the total hours this switch monitor has been operating. RESETTABLE HOUR METER This displays the total hours this cell monitor has been operating since this counter has been reset. To reset this counter to zero, press the DECREASE button. CIRCUIT BOARD TEMP This displays the temperature of internal circuit board EnCharge Power Systems PAGE 9

13 RUN GROUND FAULT PRESS INCREASE TO TEST PASSED 07/16/ :00:01 GROUND FAULT TEST Initiates a ground fault test performed on the battery string. Displays the date and duration of the most recent test and a status of either PASSED or FAILED. PRESS INCREASE TO START BATTERY TEST This will begin a battery test that will test the battery string based on the Duration and Power parameters that are set by the user. BATTERY TEST PASSED/FAILED This displays the passing or failing of the battery test and when the test was most recently performed. TEST RESULTS This displays the results of the most recent battery test performed. A total of 3 cells are viewable at a time. In order to view all of the cells, press the INCREASE button. 7.2 FAULT HISTORY MENU NOTE: Some faults may not show in Fault History until there is an actual fault. Press the decrease or increase button to reset the fault count. TOTAL TIME COUNTER Shows the total runtime of the cell monitor in days and in seconds as well as the total number of power up cycles. OVERTEMP COUNTER Shows the number of battery/charger warnings and faults. VOLTAGE FAULT COUNTER Shows the number of times the cell monitor has gone into a high or low voltage fault. CURRENT FAULT COUNTER Shows the number of times the cell monitor has gone into a high or low current fault. TIMER FAULT COUNTER Shows the number of times the cell monitor timer fault has occurred EnCharge Power Systems PAGE 10

14 OVERTEMP COUNTER Shows the number of battery/charger warnings and faults. AC POWER LOST Shows the number of times a loss of AC power has occurred. RUN COUNTER Shows the number of times the Ground Fault Test and Battery Test has been performed by the cell monitor. 7.3 SETPOINTS MENU Under the SET POINTS menu, the user defined variables are entered. The parameter screens are: PASSWORD To change any user defined parameter, use the increase button to enter the password of 5. To prevent others from changing parameters, return the password to 0 after making changes. Note: If the password is left at 5, it will automatically reset to 0 after ten minutes. USER LEVEL (Requires password) The options are BASIC and ADVANCED. BASIC - Access to the basic menu options ADVANCED Access to the advanced menu options BASIC SET POINTS BATTERY TYPE The options are GENERIC LEAD ACID, GENERIC NI-CAD. GENERIC LEAD ACID The type of battery being used is Lead Acid. GENERIC NI-CAD The type of battery being used is Ni-Cad. NUMBER OF CELLS 1-15 Lead Acid or Ni-cad cells can be used. VOLTS PER CELL\TOTAL VOLTS Each cell can be a maximum of 15VDC. The total voltage is the voltage per cell multiplied by the number of cells. HIGH VOLTAGE FAULT This adjustment is for setting the voltage level when the voltage monitor relay toggles for an over voltage fault. ( V) LOW VOLTAGE FAULT This is used to set the voltage below which the voltage monitor relay changes state. As an example, it could be set for 10% below the normal battery output voltage, to trigger an alert before the voltage dropped to a point where it would no longer operate the equipment it was attached to. ( V) ADVANCED SET POINTS HIGH CURRENT FAULT The parameter is the high amperage setting. The voltage monitor relay will toggle if the current is higher than the selected current. ( A) LOW CURRENT FAULT The voltage monitor relay will toggle if the current is lower than the selected current. This should be set lower than the expected lowest current 2018 EnCharge Power Systems PAGE 11

15 output, as when the batteries are fully charged and no equipment is running. ( A) HIGH BATTERY TEMP This setting allows the user to set the temperature that will trigger a high battery temperature fault. If a high battery temperature fault occurs, the voltage monitor relay will toggle. ( F or C) LOW BATTERY TEMP This setting allows the user to set the temperature that will trigger a low battery temperature fault. If a low battery temperature fault occurs, the voltage monitor relay will toggle. (-60-32F or -51-0C) SELECT F OR C This is used to choose the temperature units of measure. The choices are F for Fahrenheit and C for Celsius. GROUND FAULT TEST This enables the Ground Fault Detection functionality of the monitor. GRF TEST FREQ SET This sets how frequently the ground fault test is initiated. For example, it can be set hourly or daily. BATTERY CAPACITY This setting enables the Battery Capacity functionality of the monitor. BATTERY AMP HOURS This sets the size, in Amp-hours, of the battery cells being used. CURRENT SETUP This sets the configuration of up to (2) current sensors. The options are: Sensor 1 Sensor 2 Battery None Load None Charger Load Battery Charger Battery Load Table 3. Current Sensor Configurations SENSOR SN This is where the current sensor serial numbers are entered. The serial number will need to be set for each sensor. SENSOR DIRECTION This sets the direction of the current flow being monitored by the sensor. The option is Current In or Current Out. BATTERY TEST This setting enables the Battery Test functionality of the monitor. CELL MONITOR This setting enables the Cell Monitor functionality and is selected when the monitor is connected to individual battery cells EnCharge Power Systems PAGE 12

16 MY IP ADDRESS Shows the Monitor s IP address. (DHCP is enabled by default) ETHERNET MODE Allows the user to set up the battery monitor s IP address for either a network connection or a direct connection via Windows PC. PROG REV & DATE This displays the firmware revision level and the date that revision was released. 7.4 CELL MONITOR MENU **** MENU SELECT **** *** CELL MONITOR *** CELL PUCK SELECT This is used to select the active Cell Puck. There is support for up to 4 additional Cell Pucks. CELL PUCK SN This is where the serial number of the active Cell Puck is entered. Each Puck requires its serial number to be entered here. CELL PUCK NUMBER OF CELLS This is where the number of battery cells is entered for each Cell Puck. CELL VOLT DEVIATION WARNING - This sets the deviation of the average cell voltage. CELL ERROR TIMER This is the amount of time below the Cell Deviation Setpoint before it triggers a fault. CELL FAULT RESET TIMER This is the resettable amount of time below the Cell Deviation Setpoint before it triggers a fault EnCharge Power Systems PAGE 13

17 7.5 BATTERY TESTING STATUS BATTERY TEST PASSED 0 DAYS AGO HOLD INCREASE TO START BATTERY TEST PRESS INCREASE TO START BATTERY TEST This will begin a battery test that will test the battery string based on the Duration and Power parameters that are set by the user. BATTERY TEST PASSED/FAILED This displays the passing or failing of the battery test and when the test was most recently performed. TEST 1-6 RESULTS TEST RESULTS This displays the results of the most recent battery test performed. A total of 6 cells are viewable at a time. In order to view all of the cells, press the INCREASE button EnCharge Power Systems PAGE 14

18 FRA RESULTS TOTAL VOLTS: 0.00V DISCHARGE: 0Wh RUNTIME: 0 MIN FRA RESULTS This displays the total voltage, total discharge and the runtime of the most recent battery test performed. 7.6 FACTORY DEFAULTS FOR FACTORY DEFULTS PRESS DECREASE This is to allow the user to return most settings to the original factory settings by pressing the DECREASE button. A password of 5 is required to change this setting EnCharge Power Systems PAGE 15

19 7.7 RSM-SUB MONITOR Front Panel Features 15 Cell Voltage Sense Input (Red) Cell Voltage Sense Input The EnCell Guard Cell Monitor s (16) position WAGO terminal connector is used to connect the red voltage sense wires from the monitor to the battery bank. 7.8 RSM-SUB MONITOR Bottom Panel Features Dual RS485 Ports Dual RS 485 Ports The dual RS485 ports are used to supply power to Sub Monitor(s) from the Main Monitor. Sub Monitor(s) are required when more than 15 batteries/cells will be monitored. (NOTE: RS458 IS NOT FOR ETHERNET) 2018 EnCharge Power Systems PAGE 16

20 8 HOSTED WEB PAGE Settings can be changed from the hosted web page as well as from the push buttons and display on the front of the Monitor. 8.1 Login Logging in on existing Network To login, look up the IP address under the SET POINTS - MY IP ADDRESS (SECTION of this manual), and enter it in to your browser. The format should look like this Make sure to add the port number of :50000 after the IP address. (The IP address given to the monitor will be provided by the DHCP server on the network) Logging in with Direct Connection to the Battery Charger To login, first enable the Direct Connect Ethernet Mode on the battery charger. This will set the battery charger s IP address as static and allow a user to access the charger s webpage via direct Ethernet connection. NOTE: If connecting directly to the monitor from a computer, the computer and battery charger need to be on the same subnet. If the computer doesn t support Ethernet crossover detection, a crossover Ethernet cable would be required. Steps to change IP address of the Windows PC Click on the Start Menu icon in the lower left of the Desktop. In the search box, type Network and Sharing Center. Click on the Network and Sharing Center search result. Click on Change adapter settings on the left side. Right-click the Local Area Connection and then select Properties. Under This connection uses the following items, select Internet Protocol Version 4 (TCP/IPv4). Switch to the Alternate Configuration tab. To specify an IP address, select User Configured, and then, in the IP address, Subnet mask, and Default gateway boxes, type the IP address settings. o IP Address will be on the X subnet (i.e ) o Subnet mask will fill in automatically as o Default Gateway is EnCharge Power Systems PAGE 17

21 8.2 Status page Shows the status of the battery cell monitor. The hosted web page is often customized based on customer needs so may differ from the images shown below. Figure 4. System Status 2018 EnCharge Power Systems PAGE 18

22 8.3 Settings Settings tab allow you to change the settings. The username is admin, and the password is 5. The following settings will need to be set from the Hosted Webpage and can be found on the Cell Monitoring Tab: Number of Cells Cell Puck 1 SN should be set to 0 Cell Puck 2 SN should be set to (The serial number of the first Sub Monitor) Cell Puck 1 POS should be set to 0 Cell Puck 2 POS should be set to (The first cell in the number of cells connected to the Sub Monitor) Figure 5. Settings - Cell Monitoring 2018 EnCharge Power Systems PAGE 19

23 9 SPECIFICATIONS Description Input Voltage Warranty Operating Temperature (0-95% non-condensing humidity) Table 4. General Specifications -40 F to +158 F Specification +10 to 30VDC 2 Years -40 C to +70 C Table 5. Model Specifications Monitoring Model Part no. Cell Voltage No. of Cells Accuracy (per battery cell) Physical Dimensions WxHxD (in inches) RCM15S A VDC 1-15 Ni-Cad or Lead Acid ±10mV x 5.5 x 2.0 RSM15S A VDC 1-15 Ni-Cad or Lead Acid ±10mV 7.0 x 4.5 x EnCharge Power Systems PAGE 20

24 Figure 6. Wiring Diagrams for EnCell RCM Sub Monitor and Main Monitor Configuration for 15 Cells 2018 EnCharge Power Systems PAGE 21

EnCell Battery Cell Monitor

EnCell Battery Cell Monitor EnCell Battery Cell Monitor Instruction Manual Model RCM15S12 NERC Compliant YO R U H T PA TO Z O R E W O D N M I T E enchargepowersystems.com sales@enchargepowersystems.com (888) 407.5040 Contents 1 Warnings,

More information

CRAGG RAILCHARGER Instruction Manual for 10DTC-12V 20DTC-12V 30DTC-24V 40DTC-12V 60DTC-12V

CRAGG RAILCHARGER Instruction Manual for 10DTC-12V 20DTC-12V 30DTC-24V 40DTC-12V 60DTC-12V CRAGG RAILCHARGER for 10DTC-12V 20DTC-12V 30DTC-24V 40DTC-12V 60DTC-12V Contents 1 Warnings, Cautions, and Notes... 1 2 Description... 2 3 Features... 2 3.1 STANDARD FEATURES... 2 3.2 CHARGER REGULATION...

More information

Innovative Electronics for a Changing World INDEX

Innovative Electronics for a Changing World INDEX Innovative Electronics for a Changing World INDEX 1. SYSTEM DESCRIPTION 2. BOARD CONNECTIONS terminals and indicators 3. CONNECTION DIAGRAM 4. START UP GUIDE and passwords 5. HOME PAGE 6. STATUS PAGE 7.

More information

DC M2 OLED Meter Instructions PN 1830 / PN 1832 / PN 1833 / PN 1834

DC M2 OLED Meter Instructions PN 1830 / PN 1832 / PN 1833 / PN 1834 DC M2 OLED Meter Instructions PN 1830 / PN 1832 / PN 1833 / PN 1834 Installation Checklist Check for components included Read Warning and Cautions Read QuickStart Installation Guide for mounting instructions

More information

User s Manual PowerPanel Shutdown Service Graceful Shutdown and Notification service to ensure power protection of your computer

User s Manual PowerPanel Shutdown Service Graceful Shutdown and Notification service to ensure power protection of your computer User s Manual PowerPanel Shutdown Service Graceful Shutdown and Notification service to ensure power protection of your computer K01-SNMP004-00 TABLE OF CONTENTS INTRODUCTION... 1 INSTALLATION GUIDE...

More information

INDEX. Network Power Monitor R10 SNMP

INDEX. Network Power Monitor R10 SNMP Innovative Electronics for a Changing World NPM-R10 Remote Network Power Monitor With optional relay board and GSM module INDEX Amended 21 March 2017: Add user defined Password see page 13 Add wire Connection

More information

Technical Manual Nova: Cabinet Security Management System (CSMS)

Technical Manual Nova: Cabinet Security Management System (CSMS) Technical Manual Nova: Cabinet Security Management System (CSMS) KP_nova_TM_160501_EN 1 Publication May, 2016, Keyprocessor BV Paasheuvelweg 20 1105BJ Amsterdam, The Netherlands www.keyprocessor.com/nova

More information

M2 OLED Temperature Monitor Instructions PN 1841

M2 OLED Temperature Monitor Instructions PN 1841 M2 OLED Temperature Monitor Instructions PN 1841 Installation Checklist Check for components included Read Warning and Cautions Read page 3 for mounting instructions Read System Overview, Mounting Considerations,

More information

User s Manual PowerPanel Shutdown Service Graceful Shutdown and Notification service to ensure power protection of your computer

User s Manual PowerPanel Shutdown Service Graceful Shutdown and Notification service to ensure power protection of your computer User s Manual PowerPanel Shutdown Service Graceful Shutdown and Notification service to ensure power protection of your computer Version 1.3 TABLE OF CONTENTS INTRODUCTION... 1 INSTALLATION GUIDE... 4

More information

INDEX. Network Power Monitor NPM-R10-SNMP. Innovative Electronics for a Changing World. NPM-R10-SNMP Remote Network Power Monitor

INDEX. Network Power Monitor NPM-R10-SNMP. Innovative Electronics for a Changing World. NPM-R10-SNMP Remote Network Power Monitor Innovative Electronics for a Changing World NPM-R10-SNMP Remote Network Power Monitor Optional relay board and GSM module INDEX 1. SYSTEM DESCRIPTION 2. SYSTEM BATTERY CONNECTIONS 3. SERIES CONNECTED BATTERIES

More information

Innovative Electronics for a Changing World. NPM-R10 Remote Network Power Monitor. With optional relay board and GSM module INDEX

Innovative Electronics for a Changing World. NPM-R10 Remote Network Power Monitor. With optional relay board and GSM module INDEX Innovative Electronics for a Changing World NPM-R10 Remote Network Power Monitor With optional relay board and GSM module INDEX 1. SYSTEM DESCRIPTION 2. BOARD CONNECTIONS terminals and indicators 3. CONNECTION

More information

DKG-210 UNIVERSAL INTERNET GATEWAY UNIT

DKG-210 UNIVERSAL INTERNET GATEWAY UNIT DKG-210 UNIVERSAL INTERNET GATEWAY UNIT AC & DC SUPPLY VERSIONS DESCRIPTION The DKG-210 is designed for internet monitoring and control of industrial devices using different protocols through the RAINBOW

More information

ICPDAS FSM-510G Series Ethernet Management Switch Quick Start

ICPDAS FSM-510G Series Ethernet Management Switch Quick Start ICPDAS FSM-510G Series Ethernet Management Switch Quick Start Version 1.0, Dec 2014 Overview The Management Ethernet Switch solutions are designed for supporting standard industrial applications. Managed

More information

METERING/DISPLAY MANUAL

METERING/DISPLAY MANUAL METERING/DISPLAY MANUAL 175W - 750W SINGLE PHASE Series LV EMERGENCY LIGHTING CENTRAL INVERTER Myers Power Products, Inc. 44 South Commerce Way, Bethlehem, PA 18017 1-800-526-5088 (610) 868-3500 Fax: (610)

More information

Innovative Circuit Technology Ltd. Digital Series Power Supply Instruction Manual

Innovative Circuit Technology Ltd. Digital Series Power Supply Instruction Manual Innovative Circuit Technology Ltd. Digital Series Power Supply Instruction Manual 855-317-000 Rev 2.0 Feb 2018 Copyright 2018 Innovative Circuit Technology Ltd. All rights reserved. No part of this publication

More information

Hardware Installation

Hardware Installation LOLM366912 The ipio-8 is a network attached, IP addressed digital input and output device. The ipio-8 can be controlled and monitored with a standard web browser. Multiple ipio-8 devices can communicate

More information

Recommended Tools and Supplies: Small Flat Blade Screwdriver, 35mm x 7.5mm DIN Rail

Recommended Tools and Supplies: Small Flat Blade Screwdriver, 35mm x 7.5mm DIN Rail TPDIN-Monitor-WEB2 Web Based Monitor and Control Remote Power Stations Backup Power Systems Solar Systems Wind Powered Systems Industrial Sense & Control Process Automation Congratulations! on your purchase

More information

FSM-510G Series Ethernet Management Switch Quick Start Guide

FSM-510G Series Ethernet Management Switch Quick Start Guide FSM-510G Series Ethernet Management Switch Quick Start Guide Overview The Management Ethernet Switch solutions are designed for supporting standard industrial applications. Managed switches are easily

More information

Torque Series LCD Remote Panel Installation/Operation Manual Model: TQ-DSP-12/24

Torque Series LCD Remote Panel Installation/Operation Manual Model: TQ-DSP-12/24 Torque Series LCD Remote Panel Installation/Operation Manual Model: TQ-DSP-12/24 Section Page Introduction 1 Materials Provided 1 I) Safety Instructions 1 A) Inverter Safety Instructions 1 B) Battery Safety

More information

1. Short description. 2. Features. 3. Technical parameters

1. Short description. 2. Features. 3. Technical parameters 1. Short description TCW122B-RR is a remote relay control module with embedded WEB server for set up. The device has two digital inputs and two relays, with normally open and normally closed contacts.

More information

Energy Client. Version Feb Electrocom Rødeledsvej 95 DK-5700 Svendborg Denmark Tel:

Energy Client. Version Feb Electrocom Rødeledsvej 95 DK-5700 Svendborg Denmark Tel: Energy Client Version 2.0.806 3. Feb. 2014 Electrocom Rødeledsvej 95 DK-5700 Svendborg Denmark Tel: +45 88 80 75 80 www.electrocom.dk p. 2 Introduction... 3 Installation... 4 LED, Switches and Reset...

More information

SNMP Web Management. User s Manual

SNMP Web Management. User s Manual SNMP Web Management User s Manual Suitable Product: SNMP Web Card SNMP Web Box Management Software for Uninterruptible Power Supply Systems Table of Contents 1. Overview... 1 1.1 Introduction... 1 1.2

More information

Innovative Electronics for a Changing World. Charge Smart R1 MPPT 12V/24V Auto detect Mains and Solar Battery charger with Remote Network Monitoring

Innovative Electronics for a Changing World. Charge Smart R1 MPPT 12V/24V Auto detect Mains and Solar Battery charger with Remote Network Monitoring Innovative Electronics for a Changing World Charge Smart R1 MPPT 12V/24V Auto detect Mains and Solar Battery charger with Remote Network Monitoring INDEX 1. SYSTEM DESCRIPTION 2. SYSTEM WIRING 3. SYSTEM

More information

Plus-X I/O Units. Manual Supplement Configuring Units with and without DHCP

Plus-X I/O Units. Manual Supplement Configuring Units with and without DHCP Plus-X I/O Units Manual Supplement Configuring Units with and without DHCP Table of Contents Introduction... 1 Initial Connection Using DHCP... 1 Initial Connection Without DHCP... 2 Set a Static IP Address...

More information

ACCESS 9340/9360 Meter Input/Output Module

ACCESS 9340/9360 Meter Input/Output Module Installation Manual PMIM-IOMOD-0208 ACCESS 9340/9360 Meter Input/Output Module 9340-60-I/O2222 and 9340-60-I/O26 HAZARD CATEGORIES AND SPECIAL SYMBOLS Read these instructions carefully and look at the

More information

Industrial Serial Device Server

Industrial Serial Device Server 1. Quick Start Guide This quick start guide describes how to install and use the Industrial Serial Device Server. Capable of operating at temperature extremes of -10 C to +60 C, this is the Serial Device

More information

OPERATING PROCEDURES for the UPS-S2 Universal Power Supply Series 2

OPERATING PROCEDURES for the UPS-S2 Universal Power Supply Series 2 OPERATING PROCEDURES for the Universal Power Supply Series 2 Vanguard Instruments Co., Inc. 1520 S. Hellman Ave. Ontario, California 91761 TEL: 909-923-9390 November 2013 FAX: 909-923-9391 REV. 2 SAFETY

More information

ILF-100WD User Manual. Router Watchdog / Connection Monitor 2007 Stealth Laboratories, LLC Patent Pending

ILF-100WD User Manual. Router Watchdog / Connection Monitor 2007 Stealth Laboratories, LLC Patent Pending ILF-100WD User Manual Router Watchdog / Connection Monitor 2007 Stealth Laboratories, LLC Patent Pending Rev. 1.17 02/24/2009 Table of Contents Installation and Configuration...3 Network Configuration...4

More information

Please take serious note of the following warnings:

Please take serious note of the following warnings: TPDIN-SC48-20 MPPT Solar Controller with Passive PoE Switch Wireless Base Stations and Client Devices Surveillance Cameras Remote Control Remote Lighting Off Grid Electronics Congratulations! on your purchase

More information

Sidewinder Pumps Inc. AC Timer/Controller

Sidewinder Pumps Inc. AC Timer/Controller Sidewinder Pumps Inc. AC Timer/Controller Page 1 of 12 Rev 032417 Table of Contents 1. Warnings-------------------------------------------------------------------------------------------------- 3 1.1.

More information

Installation of the PCMeasure Movement Sensor (30114)

Installation of the PCMeasure Movement Sensor (30114) 1. Hardware: Installation of the PCMeasure Movement Sensor (30114) Connect the sensor to a serial or parallel port of the PC using one of the PCMeasure adaptors, or directly to the PCMeasure Ethernet Box.

More information

SEI DC-UPS Power Management Package Users Manual

SEI DC-UPS Power Management Package Users Manual SEI DC-UPS Power Management Package Users Manual (301) 694-9601 (800) 765-4734 Fax (301) 694-9608 Email: info@seipower.com www.seipower.com 5115 Pegasus Court Suite Q Frederick, MD 21704 1. Introduction

More information

AC M2 OLED Meter Instructions PN 1836/ PN 1837 / PN 1838

AC M2 OLED Meter Instructions PN 1836/ PN 1837 / PN 1838 AC M2 OLED Meter Instructions PN 1836/ PN 1837 / PN 1838 Installation Checklist Check for components included Read Warning and Cautions Read QuickStart Installation Guide for mounting instructions Read

More information

Dryer. M720 Programming and Operation Manual. July 15, 2015 Revision 1.51

Dryer. M720 Programming and Operation Manual. July 15, 2015 Revision 1.51 Dryer M720 Programming and Operation Manual July 15, 2015 Revision 1.51 Contents 1 Important Safety Information 1 1.1 FOR YOUR SAFETY - CAUTION!............................. 1 2 Control Overview 2 2.1

More information

Energy Management System. Operation and Installation Manual

Energy Management System. Operation and Installation Manual Energy Management System Operation and Installation Manual AA Portable Power Corp 825 S 19 TH Street, Richmond, CA 94804 www.batteryspace.com Table of Contents 1 Introduction 3 2. Packing List 5 3. Specifications

More information

Guide Specification for 3G Wireless Battery Monitoring System

Guide Specification for 3G Wireless Battery Monitoring System Guide Specification for 3G Wireless Battery Monitoring System 3/11A FirstLine Wireless BMS 1 1.0 Scope This specification defines the minimum requirements for a predictive FirstLine Wireless Battery Monitoring

More information

H3G-TA ENGINEERING MANUAL

H3G-TA ENGINEERING MANUAL ENGINEERING MANUAL Table of Contents Tools required for installation and Debugging... 1 1 Overview... 4 2 System Components and Module Description...5 2.1 System Components... 5 2.2 TA Module...6 2.3 CM

More information

The GV-I/O Box 16 Ports provides 16 inputs and 16 relay outputs, and supports both DC and AC output voltages.

The GV-I/O Box 16 Ports provides 16 inputs and 16 relay outputs, and supports both DC and AC output voltages. GV-I/O Box 16 Ports The GV-I/O Box 16 Ports provides 16 inputs and 16 relay outputs, and supports both DC and AC output voltages. Key Features 16 inputs and 16 outputs are provided. Up to 9 pieces of GV-I/O

More information

Netbiter EC300 Series

Netbiter EC300 Series Netbiter EC300 Series USER MANUAL SCM-1202-012 2.2 ENGLISH Important User Information Liability Every care has been taken in the preparation of this document. Please inform HMS Industrial Networks AB of

More information

8380 RPC Return Path Combiner. User s Guide

8380 RPC Return Path Combiner. User s Guide 8380 RPC Return Path Combiner User s Guide Notice Every effort was made to ensure that the information in this manual was accurate at the time of printing. However, information is subject to change without

More information

THE i-stat 1 DOWNLOADER/RECHARGER (MODEL NUMBER DRC-300)

THE i-stat 1 DOWNLOADER/RECHARGER (MODEL NUMBER DRC-300) i-stat TECHNICAL BULLETIN THE i-stat 1 DOWNLOADER/RECHARGER (MODEL NUMBER DRC-300) OVERVIEW This Technical Bulletin describes the instructions for using the new i-stat 1 Downloader/Recharger (DRC), which

More information

Table of Contents. The Botron B92700 OMNIGND is a Multi-Ground Continuous Monitoring Automation System.

Table of Contents. The Botron B92700 OMNIGND is a Multi-Ground Continuous Monitoring Automation System. Operation Manual Table of Contents Description: The Botron B92700 OMNIGND is a Multi-Ground Continuous Monitoring Automation System. Directory: Overview Pg. 2 Features Pg. 3 Quick Setup Guide Pg. 3 Settings

More information

ROCKETLINX ES8508 ES8508 ES8508F ES8508-XT ES8508F-XT QUICK INSTALLATION GUIDE

ROCKETLINX ES8508 ES8508 ES8508F ES8508-XT ES8508F-XT QUICK INSTALLATION GUIDE ROCKETLINX ES8508 ES8508 ES8508F ES8508-XT ES8508F-XT QUICK INSTALLATION GUIDE 2000577 Rev B Release Date - September, 2013 INTRODUCTION The RocketLinx ES8508 series features advanced Layer 2 management

More information

Autoranging True RMS Multimeter User Manual

Autoranging True RMS Multimeter User Manual Autoranging True RMS Multimeter User Manual Please read this manual before switching the unit on. Important safety information inside. Contents Page 1. Safety Information... 4 2. Safety Symbols... 5 3.

More information

ACTpro Single Door IP Controller. Operating & Installation Instructions

ACTpro Single Door IP Controller. Operating & Installation Instructions ACTpro 1500 Single Door IP Controller Operating & Installation Instructions 18-00079 Issue 1 This manual refers to the ACTpro 1500 a TCP/IP based control unit supporting up to 32 doors. Access Control

More information

INTEGRATED SYSTEMS AND CONTROL, INC. User s Hardware Manual. PCMNET V 7. xx

INTEGRATED SYSTEMS AND CONTROL, INC. User s Hardware Manual. PCMNET V 7. xx INTEGRATED SYSTEMS AND CONTROL, INC. User s Hardware Manual PCMNET V 7. xx INTEGRATED SYSTEMS AND CONTROLS, INC. PCMNET Users Manual Revised 2/4/2005 2003-2005 Integrated Systems and Control. Inc. PO Box

More information

8~14-Port Managed Ethernet Switch

8~14-Port Managed Ethernet Switch 8~14-Port Managed Ethernet Switch Quick Installation Guide Overview The Managed Ethernet Switch solutions are designed for supporting standard industrial applications. Managed switches are easier to prioritize,

More information

Innovative Circuit Technology Ltd.

Innovative Circuit Technology Ltd. Innovative Circuit Technology Ltd. Digital Series Power Supply Instruction Manual 855-317-000 Rev 1.5 April 2013 Copyright 2012 Innovative Circuit Technology Ltd. All rights reserved. No part of this publication

More information

Quick Installation Guide

Quick Installation Guide Manual# 1100274 Quick Installation Guide SDU 410 Safety Unit Quick Installation Guide for SDU 410 Safety Unit ~~~ Revision 1.1 Revised November 10, 2016 Revision history: Rev. Date Description 1.0 04.2012

More information

Mate Serial Communications Guide This guide is only relevant to Mate Code Revs. of 3.30 and greater

Mate Serial Communications Guide This guide is only relevant to Mate Code Revs. of 3.30 and greater Mate Serial Communications Guide This guide is only relevant to Mate Code Revs. of 3.30 and greater For additional information contact matedev@outbackpower.com Page 1 of 14 Revision History Revision 2.0:

More information

Mini Digital Multimeter

Mini Digital Multimeter User's Guide Mini Digital Multimeter Model MN15 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com Back to the Extech MN15/MN16 Series

More information

Contents. GV-I/O Box 8 Ports Key Features Compatible Software Packing List Overview DIP Switch...

Contents. GV-I/O Box 8 Ports Key Features Compatible Software Packing List Overview DIP Switch... Contents GV-I/O Box 8 Ports...2 1. Key Features... 2 2. Compatible Software... 2 3. Packing List... 2 4. Overview... 3 5. DIP Switch... 3 6. Connections to PC... 4 6.1 Installing USB Driver... 5 6.2 Assigning

More information

Installing and Configuring Rialto Analytic Appliances

Installing and Configuring Rialto Analytic Appliances Installing and Configuring Rialto Analytic Appliances Important Safety Information This manual provides installation and operation information and precautions for the use of this camera. Incorrect installation

More information

QUICK SETUP GUIDE. BCM2 Series Branch Circuit Monitors. Safety Information. Equipment Maintenance and Service. Raritan DANGER!

QUICK SETUP GUIDE. BCM2 Series Branch Circuit Monitors. Safety Information. Equipment Maintenance and Service. Raritan DANGER! QUICK SETUP GUIDE BCM2 Series Branch Circuit Monitors Safety Information DANGER! HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH Follow safe electrical work practices. See NFPA 70E in the USA, or applicable

More information

S-14 S-14. Compact Digital Multimeter. Compact Digital Multimeter

S-14 S-14. Compact Digital Multimeter. Compact Digital Multimeter S-14 Compact Digital Multimeter S-14 Compact Digital Multimeter SAFETY INFORMATION The following safety information must be observed to insure maximum personal safety during the operation at this meter

More information

5450 NW 33rd Ave, Suite 104 Fort Lauderdale, FL Fruitland Ave Los Angeles, CA SST7000 SST7100. Speed Switch / Transmitter

5450 NW 33rd Ave, Suite 104 Fort Lauderdale, FL Fruitland Ave Los Angeles, CA SST7000 SST7100. Speed Switch / Transmitter 5450 NW 33rd Ave, Suite 104 Fort Lauderdale, FL 33309 3211 Fruitland Ave Los Angeles, CA 90058 SST7000 SST7100 Speed Switch / Transmitter Installation and Operation Manual Rev. C P/N145F-13112 PCO 00009270

More information

OPERATING INSTRUCTION

OPERATING INSTRUCTION OPERATING INSTRUCTION AUTORANGING MULTIMETER MAX Ω F C 10A MAX every 15 min. COM V SAFETY INFORMATION The following safety information must be observed to insure maximum personal safety during the operation

More information

Manual# Installation Manual SDU 410. Safety Shutdown Unit

Manual# Installation Manual SDU 410. Safety Shutdown Unit Manual# 1100641 Installation Manual SDU 410 Safety Shutdown Unit Installation Manual for SDU 410 ~~~ Safety Shutdown Unit Revision 1.0 Revised August 31, 2017 Revision history: Rev. Date Description 1.0

More information

OWNER S MANUAL 9908-TE. HIGH PRECISION AUTO-RANGING DC/True RMS AC BENCH-TOP DIGITAL MULTIMETER

OWNER S MANUAL 9908-TE. HIGH PRECISION AUTO-RANGING DC/True RMS AC BENCH-TOP DIGITAL MULTIMETER OWNER S MANUAL 9908-TE HIGH PRECISION AUTO-RANGING DC/True RMS AC BENCH-TOP DIGITAL MULTIMETER IMPORTANT! Read and understand this manual before using the instrument. Failure to understand and comply with

More information

EnerSure Installation Guide

EnerSure Installation Guide EnerSure Installation Guide Danger!!! The electrical components of this system may contain voltage and /or amperage sufficient to injure or kill. Installation is only to be performed by a licensed, bonded

More information

MicroTech II McQuay Maverick II Rooftop Unit Controller BACnet Communication Module, Ethernet or IP

MicroTech II McQuay Maverick II Rooftop Unit Controller BACnet Communication Module, Ethernet or IP Installation and Maintenance Manual IM 853 Group: Controls Part Number: IM 853 Date: June 2007 Supercedes: New MicroTech II McQuay Maverick II Rooftop Unit Controller BACnet Communication Module, Ethernet

More information

MODEL CIO-EN MODBUS/TCP, MODBUS/RTU I/O MODULE

MODEL CIO-EN MODBUS/TCP, MODBUS/RTU I/O MODULE INSTALLATION INSTRUCTIONS Revision B1 Rapid City, SD, USA, 05/2009 MODEL CIO-EN MODBUS/TCP, MODBUS/RTU I/O MODULE BE SURE POWER IS DISCONNECTED PRIOR TO INSTALLATION! FOLLOW NATIONAL, STATE AND LOCAL CODES.

More information

Owner's Manual. True RMS Multimeter. Model No Safety Operation Maintenance Español

Owner's Manual. True RMS Multimeter. Model No Safety Operation Maintenance Español Owner's Manual True RMS Multimeter Model No. 82023 CAUTION: Read, understand and follow Safety Rules and Operating Instructions in this manual before using this product. Safety Operation Maintenance Español

More information

QUICK SETUP GUIDE PMC-1000, PMC-1001, PMM-1000, PMB PM Series Power Meter. Safety Information. Equipment Maintenance and Service.

QUICK SETUP GUIDE PMC-1000, PMC-1001, PMM-1000, PMB PM Series Power Meter. Safety Information. Equipment Maintenance and Service. PM Series Power Meter QUICK SETUP GUIDE PMC-1000, PMC-1001, PMM-1000, PMB-1960 Safety Information DANGER! HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH Follow safe electrical work practices. See NFPA

More information

H3G-TV ENGINEERING MANUAL

H3G-TV ENGINEERING MANUAL ENGINEERING MANUAL Hangzhou Huasu Jada Technology Co., Ltd No.16, Xiyuan Wu Road, Westlake Tech-economy Zone, Hangzhou, China TEL: 0086-571-87967915 FAX:0086-571-87968969 www.huasucn.com Hangzhou Huasu

More information

Ethernet/Network Communications Module. Installation and Programming Manual. LINQ2 - Two (2) Port Connectivity Module. More than just power.

Ethernet/Network Communications Module. Installation and Programming Manual. LINQ2 - Two (2) Port Connectivity Module. More than just power. Ethernet/Network Communications Module Installation and Programming Manual LINQ2 - Two (2) Port Connectivity Module DOC#: LINQ2 Rev. 060514 More than just power. Overview: Altronix LINQ2 network module

More information

DM-918 OPERATIONS MANUAL AUTORANGING MULTIMETER

DM-918 OPERATIONS MANUAL AUTORANGING MULTIMETER DM-918 OPERATIONS MANUAL AUTORANGING MULTIMETER SAFETY INFORMATION The following safety information must be observed to ensure maximum personal safety during the operation of this meter: This meter is

More information

SMM Series 3G and GSM Modems. Quick Start Guide. Document Number: Version: 1.2 (20 October, 2015)

SMM Series 3G and GSM Modems. Quick Start Guide. Document Number: Version: 1.2 (20 October, 2015) SMM Series 3G and GSM Modems Quick Start Guide Document Number: 0013-001-000272 () Documentation Control Generation Date: October 20, 2015 Cybertec Pty Limited All rights Reserved. No part of this publication

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS BACnet Communication Card RXRX-AY01 RECOGNIZE THIS SYMBOL AS AN INDICATION OF IMPORTANT SAFETY INFORMATION! WARNING THESE INSTRUCTIONS ARE INTENDED AS AN AID TO QUALIFIED, LICENSED

More information

Instruction Manual. 2in1 LAN Tester & Multimeter. Model: 57314

Instruction Manual. 2in1 LAN Tester & Multimeter. Model: 57314 Instruction Manual 2in1 LAN Tester & Multimeter Model: 57314 1 Contents Introduction... Features... Safety Precautions.. Meter Description... Electrical Specification... Operation.. AutoRanging Multimeter.

More information

Multi-instrument Communication, MIC-2 MKII DIN Quick Start Guide

Multi-instrument Communication, MIC-2 MKII DIN Quick Start Guide Multi-instrument Communication, MIC-2 MKII DIN Quick Start Guide Warnings and legal information Installation and terminals Communication I/O options Alarming Utility software More information Specifications

More information

Mini Digital Multimeter

Mini Digital Multimeter User Manual Mini Digital Multimeter Model MN15A Additional User Manual Translations available at www.extech.com Introduction Congratulations on your purchase of the Extech MN15A MultiMeter. The MN15A offers

More information

7NOX User Manual for Site Device. Book after-hours air conditioning in commercial buildings with ease.

7NOX User Manual for Site Device. Book after-hours air conditioning in commercial buildings with ease. 7NOX User Manual for Site Device Book after-hours air conditioning in commercial buildings with ease. Document Control Revision History This document is version controlled via the use of revision numbers.

More information

BTRM200 Battery Test Remote Monitor. User Guide

BTRM200 Battery Test Remote Monitor. User Guide BTRM200 Battery Test Remote Monitor User Guide Contact : Ventev Wireless Infrastructure 11126 McCormick Road Hunt Valley, MD 21031 Phone Number 800.851.4965 Email Sales@ventev.com Ventev Wireless Infrastructure

More information

DUAL SWITCH CONTROLLER

DUAL SWITCH CONTROLLER DUAL SWITCH CONTROLLER INSTRUCTION MANUAL IMPORTANT: If the Dual Switch Controller is to be used with a Dielectric 50000 Series Switch, control cable P/N 1100007364 or 11000007365 must be used. See Section

More information

170 ADM to 60 VDC Module Base / 170 ADO Pt. Relay Out Module Base. Version 1.0

170 ADM to 60 VDC Module Base / 170 ADO Pt. Relay Out Module Base. Version 1.0 170 ADM 850 10 10 to 60 VDC Module Base / 170 ADO 830 30 6 Pt. Relay Out Module Base Version 1.0 31005197 00 Safety Information NOTICE Read these instructions carefully, and look at the equipment to become

More information

FPA-1000-V2 Network Cards FPE-1000-NE, FPE-1000-NF, and FPE-1000-NW

FPA-1000-V2 Network Cards FPE-1000-NE, FPE-1000-NF, and FPE-1000-NW FPA-1000-V2 Network Cards FPE-1000-NE, FPE-1000-NF, and FPE-1000-NW en Installation manual FPA-1000-V2 Network Cards Table of contents en 3 Table of contents 1 General Information 4 1.1 Safety 4 1.2 Network

More information

Version 1.0c May 6, 2010 ATK3

Version 1.0c May 6, 2010 ATK3 Version 1.0c May 6, 2010 ATK3 Contents 1 Hardware 2 1.1 Inputs............................... 2 1.2 Outputs.............................. 3 1.3 RS485............................... 3 1.4 Ethernet..............................

More information

RGM180 Display Series

RGM180 Display Series Quick Start Guide RGM180 Display Series BG0509 REV.A2 RGM180 QUICKSTART LIMITED WARRANTY The manufacturer offers the customer a 24-month functional warranty on the instrument for faulty workmanship or

More information

Hardened Web-Smart High Power PoE Ethernet Switch

Hardened Web-Smart High Power PoE Ethernet Switch Quick Start Guide This quick start guide describes how to install and use the Hardened Web-Smart High Power PoE (Power over Ethernet) Ethernet Switch. This is the switch of choice for harsh environments

More information

BCM2 Series Branch Circuit Monitors Quick Setup Guide

BCM2 Series Branch Circuit Monitors Quick Setup Guide BCM2 Series Branch Circuit Monitors Quick Setup Guide Safety Information DANGER! HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH Follow safe electrical work practices. See NFPA 70E in the USA, or applicable

More information

5450 NW 33rd Ave, Suite 104 Fort Lauderdale, FL Fruitland Ave Los Angeles, CA UM Channel Monitor.

5450 NW 33rd Ave, Suite 104 Fort Lauderdale, FL Fruitland Ave Los Angeles, CA UM Channel Monitor. 5450 NW 33rd Ave, Suite 104 Fort Lauderdale, FL 33309 3211 Fruitland Ave Los Angeles, CA 90058 UM-600 6-Channel Monitor Version 2 Installation and Operation Manual Rev. G P/N145F-12990 PCO 00007462 (c)

More information

PM Series Power Meter

PM Series Power Meter PM Series Power Meter Quick Setup Guide - PMC-1000, PMC- 1001, PMM-1000, PMB-1960 Safety Information DANGER! HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH Follow safe electrical work practices. See

More information

BEP 600-ACSM AC SYSTEMS MONITOR. Installation and Operating Instructions. Page 1

BEP 600-ACSM AC SYSTEMS MONITOR. Installation and Operating Instructions. Page 1 BEP 600-ACSM AC SYSTEMS MONITOR Installation and Operating Instructions Page 1 This page has been deliberately left blank Page 2 Table of Contents 1. BASICS 4 WARNING AND CAUTION 4 WARNING 4 CAUTION 4

More information

EMC-1 TM. Ethernet Meterbus Converter. DIMENSIONS [inches (millimeters)] Installation and Operation Manual

EMC-1 TM. Ethernet Meterbus Converter. DIMENSIONS [inches (millimeters)] Installation and Operation Manual EMC-1 TM Ethernet Meterbus Converter Installation and Operation Manual DIMENSIONS [inches (millimeters)] 4.85 ( 123 ) For the most recent manual revisions, see the version at: www.morningstarcorp.com 3.37

More information

PowerLogic TM Series E4800 Multi-Circuit Meters. Configuration Guide

PowerLogic TM Series E4800 Multi-Circuit Meters. Configuration Guide PowerLogic TM Series E4800 Multi-Circuit Meters Configuration Guide PowerLogic TM E4800 Series 930-112-01 02/2009 Hazard Categories and Special Symbols Read these instructions carefully and look at the

More information

OilCop Component Wiring Installation Manual

OilCop Component Wiring Installation Manual OilCop Component Wiring Installation Manual This info sheet contains important information. READ AND KEEP FOR REFERENCE. 2311 S. Edwards Wichita, KS 67213 TEL: 316-943-5477 FAX: 316-943-4760 TOLL FREE:

More information

IP Sensor IPS2222 User manual

IP Sensor IPS2222 User manual IP Sensor IPS2222 User manual Output LED indicators Power input 12VDC adapter 2 Relay outputs LED Indicators 1 wire 2 Dry 2 Analog Green : Power Yellow: Link temperature & humidity contact inputs inputs

More information

MC1000 Multi-Function Calibrator

MC1000 Multi-Function Calibrator MC1000 Multi-Function Calibrator Table of Contents 1. Introduction 1.1 Customer Service................1 1.2 Standard Equipment..............1 1.3 Safety Information................2 2. Quick Start Instructions

More information

MICRO SERIES PROCESS DISPLAYS LARGE DIGIT MODELS

MICRO SERIES PROCESS DISPLAYS LARGE DIGIT MODELS The MICRO SERIES PROCESS DISPLAYS LARGE DIGIT MODELS Mighty-5 DPM MODELS Micro-P & Mighty-1 Mighty-1 Micro-P ELECTRO-NUMERICS, INC. Introduction The Electro-Numerics family of Digital Panel Meters and

More information

Hardened Web-Smart PoE & High Power PoE Ethernet Switch

Hardened Web-Smart PoE & High Power PoE Ethernet Switch Quick Start Guide This quick start guide describes how to install and use the Hardened Web-Smart PoE (Power over Ethernet) and High Power PoE Ethernet Switch. This is the switch of choice for harsh environments

More information

Replacing a Precision Controller Circuit Board

Replacing a Precision Controller Circuit Board Instruction heet Replacing a Precision Controller Circuit Board WARNING: Allow only qualified personnel to perform the following tasks. Observe and follow the safety instructions in this document and all

More information

H3G-48B Production Description

H3G-48B Production Description H3G-48B Production Description Designed for communication battery strings of 24 batteries each of VRLA and Ni-Cd battery 1 Applications For strings of 24 batteries each Base Station (2V X 24 batteries)

More information

NEUROLOGIC RESEARCH CORPORATION MODEL 2500

NEUROLOGIC RESEARCH CORPORATION MODEL 2500 NEUROLOGIC RESEARCH CORPORATION MODEL 2500 NETWORK HUMISTAT Compact, self-contained dehumidifier controller. 0.5 degrees C accuracy typical. RH sensor is digitally calibrated for 2% accuracy. Open communication

More information

9120 Redundant Probe System (RPSC)

9120 Redundant Probe System (RPSC) 9120 Redundant Probe System (RPSC) USER S MANUAL Super Systems Inc. 7205 Edington Drive Cincinnati, OH 45249 Ph : 513-772-0060, 800-666-4330 Fax: 513-772-9466 www.supersystems.com Super Systems Inc. help

More information

Installation and Operation Back-UPS BR1000G-IN / BR1500G-IN

Installation and Operation Back-UPS BR1000G-IN / BR1500G-IN Installation and Operation Back-UPS BR1000G-IN / BR1500G-IN Important Safety Information Read the instructions carefully to become familiar with the equipment before trying to install, operate, service

More information

PM174 PM174 IEEE1159 ADVANCED POWER QUALITY ANALYZER. Features

PM174 PM174 IEEE1159 ADVANCED POWER QUALITY ANALYZER. Features PM174 IEEE1159 ADVANCED POWER QUALITY ANALYZER The PM174 is a compact, multi-function, three-phase AC powermeter and power quality analyzer specially designed to meet the requirements of users ranging

More information

TT /12b INSTALLATION INSTRUCTIONS. Introduction

TT /12b INSTALLATION INSTRUCTIONS. Introduction TT-1545 11/12b INSTALLATION INSTRUCTIONS Original Issue Date: 6/10 Model: 20-300 kw Generator Sets Market: Industrial Subject: Decision-Maker 3000 Controller Service Replacement Kit GM75376 Introduction

More information

4-port 10/100TX + 1 or 2-port 100FX Industrial Switch. User Manual

4-port 10/100TX + 1 or 2-port 100FX Industrial Switch. User Manual 4-port 10/100TX + 1 or 2-port 100FX Industrial Switch User Manual Rev.1.03 Sep-2010 FCC Warning This Equipment has been tested and found to comply with the limits for a Class A digital device, pursuant

More information

PS/IO Circuit Board Retrofit

PS/IO Circuit Board Retrofit S&C 6800 Series Automatic Switch Controls PS/IO Circuit Board Retrofit Table of Contents Section Page Introduction Qualified Persons.... 2 Read this Instruction Sheet.... 2 Retain this Instruction Sheet....

More information