The AMG5903A966 is designed to be powered using an AMG2003 standalone or equivalent power supply.

Size: px
Start display at page:

Download "The AMG5903A966 is designed to be powered using an AMG2003 standalone or equivalent power supply."

Transcription

1 MG Instruction Manual Data Transmit Unit with 2 Bidirectional Data Channels, 6 Bidirectional udio Channels, 2 Echelon FTT10 Data Channels and 8 Bidirectional larms plus Ethernet for a Singlemode Fibre Link The MG is a standalone data transmit unit designed to transmit and receive 2 data channels, 6 audio channels, 2 Echelon FTT10 data channels and 8 bidirectional alarms over one Singlemode optical fibre. It also provides full duplex 100BaseT Ethernet connectivity. The MG is designed to be powered using an MG2003 standalone or equivalent power supply. The MG is designed to operate with an MG standalone or MG G rackmount data receive unit in a point to point configuration. MG Systems Ltd. reserves the right to make changes to this be accurate. No responsibility is assumed by MG for its use. Page 1 of 12 MG Instruction Sheet D doc

2 Contents Introduction 3 Unit Functional Schematic... 3 Optical Connection... 3 Connections 4 Optical Connection Singlemode... 4 Power Connection... 4 Data and larm Channel Connections... 4 udio Connections... 4 Echelon FTT10 Data Channel Connection... 5 Ethernet Connection... 5 Front Panel Indicators 6 Power LED... 6 Low Speed Data LEDs... 6 udio LEDs... 6 larm LEDs... 7 Echelon FTT10 Data LEDs... 7 Ethernet Data LEDs... 7 Ethernet Operation 7 Data and larm Channel Configuration 8 Data Channel Configuration... 8 Data Interface Connections... 8 Data Channel Termination... 8 larm Channel Configuration... 9 larm Channel Circuit... 9 larm Interface Connections udio Channel Connections Echelon FTT10 Data Channel Configuration Data and udio Connections Physical Information 12 Dimensions Mounting Details Safety 12 Maintenance and Repair 12 MG Systems Ltd. reserves the right to make changes to this be accurate. No responsibility is assumed by MG for its use. Page 2 of 12 MG Instruction Sheet D doc

3 Introduction Unit Functional Schematic The MG transmits and receives 2 data channels, 6 bidirectional audio signals and 8 bidirectional alarm signals to/from the MG receive unit. Ethernet connectivity is also provided between the two units. Optical Connection The MG connections are illustrated in the following example which shows an MG data transmit unit together with an MG G rackmount data receive unit configured as a point to point system. MG Systems Ltd. reserves the right to make changes to this be accurate. No responsibility is assumed by MG for its use. Page 3 of 12 MG Instruction Sheet D doc

4 Connections Optical Connection Singlemode Optical Fibre...Singlemode Connector...SC/PC Primary Optical Launch Power...10dBm Transmit Wavelength nm Primary Optical Sensitivity...30dBm Receive Wavelength nm Minimum Optical Dynamic Range...20dB. Power Connection Connector Type...Removable 2pin, 3.81mm, Screw Terminal Connector Partno...Phoenix Supply Voltage to +15 Volts DC Maximum Power...10 Watts Data and larm Channel Connections No. of Data Channels...2 No. of larms...8 Connectors...Removable 5pin, 3.5mm, Spring Terminal Connector Partnos...Phoenix Data Interfaces...RS232 / 422 / 485. Selected by external slide switches D1D2 RS232 Switch Position Top RS422 Switch Position Middle RS485 Switch Position Bottom Internal 120Ω termination resistors may be applied to RS422 or RS485 inputs as required by internal DIL switches inside the enclosure. *See appropriate section on how to remove the case for access to the DIL switches. larm inputs...input is via a series 10k resister with 47kΩ pullup to +3V3. larm outputs...output is NPN open collector, maximum load 24Vdc. udio Connections Data/udio Channels BNK...6 udio channels Data/udio Channels BNK B...Not Used Connector...37way DType female connector shielded. Connections...See below for connection and configuration Input level...40dbm to 0dBm Input overload level...+6dbm Input impedance...56kω / 600Ω. Each channel individually selected using DIL switch on front panel Output impedance...600ω Frequency response...10hz to 20KHz MG Systems Ltd. reserves the right to make changes to this be accurate. No responsibility is assumed by MG for its use. Page 4 of 12 MG Instruction Sheet D doc

5 Echelon FTT10 Data Channel Connection No. of Echelon FTT10 Data Channels 2 Echelon FTT10 BNK... Channels 7 and 8 Echelon FTT10 BNK B... None Connector... 37way DType female connectors shielded. Connections... See appropriate section for full details Ethernet Connection Ethernet Data Connector... RJ45 Interface... uto MDI/MDIX 100BSETX Ethernet Data Rate... Maximum 100Mb/s full duplex MG Systems Ltd. reserves the right to make changes to this be accurate. No responsibility is assumed by MG for its use. Page 5 of 12 MG Instruction Sheet D doc

6 Front Panel Indicators Power LED POWER...Green Power is present Power is not present VIDEO... Not used OPTO TX...Green Tx opto. present Tx opto. is not present OPTO RX...Green Rx opto. sync. Rx opto. is not sync. Data Present IN (RS485 or RS422)...Green Red logic zero (+V, V) present on IN+, INlogic one (V,V+) present on IN+, INtristate off or no connection on IN+, IN Data Present IN (RS232)...Green Red logic zero (+V) present on input IN+ logic transitions present on input IN+ logic one (V) present on input IN+ Low Speed Data LEDs IN corresponds to the data signals being transmitted onto the optical fibre. Data Present OUT (RS485 or RS422) Green Red logic zero (+V,V) present on OUT+, OUTlogic one (V,+V) present on OUT+, OUTtristate off or no connection on OUT+, OUT Data Present OUT (RS232)...Green Red logic zero (+V) present on OUT+ logic transitions present on OUT+ logic one (V) present on OUT+ OUT corresponds to the data signals being received from the optical fibre. udio LEDs Channels 16 udio Present TX...Green Red audio present > 40dBm audio present > 0dBm (overload at +6dBm) audio not present or < 40dBm This represents the audio signals being transmitted on the optical fibre udio Present RX...Green Red audio present > 40dBm audio present > 0dBm (overload at +6dBm) audio not present or < 40dBm This represents the audio signals being received from the optical fibre. MG Systems Ltd. reserves the right to make changes to this be accurate. No responsibility is assumed by MG for its use. Page 6 of 12 MG Instruction Sheet D doc

7 larm LEDs Channels 18 LRM IN... Green larm ON / Contacts closed. larm OFF / Contacts open. LRM OUT... Green larm ON / Contacts closed. larm OFF / Contacts open. Echelon FTT10 Data LEDs Data type depends on MG system: RS232, RS422, RS485, 20m,TTL, or FTT10 Data Present IN... Green R/G Data channel present but not transmitting Data channel transmitting Data channel not present or no connection IN corresponds to the data signals being transmitted onto the optical fibre. Data Present OUT... Green R/G Data channel present but not transmitting Data channel receiving Data channel not present or no connection OUT corresponds to the data signals being received from the optical fibre. Ethernet Data LEDs Link not Present... Yellow Link Integrity... Green GBlink Link not present Link is present Link integrity is good, Idle state Data transfer Link not present Ethernet Operation The Ethernet interface supports 100Mbit/s full duplex operation only. Data is transmitted from one port the other port with minimum delay or buffering. The port implements "uto MDI/MDIX" i.e. it may be connected with either a straightthough or crossover cable to an appropriate device such as external switch, PC or other DCE/DTE. Two LED indicators are provided adjacent to the RJ45 port: Green indicates Link / Data transfer and Yellow indicates no Ethernet connection. MG Systems Ltd. reserves the right to make changes to this be accurate. No responsibility is assumed by MG for its use. Page 7 of 12 MG Instruction Sheet D doc

8 Data and larm Channel Configuration The MG transmit unit sends and receives data to/from an MG or rackmount equivalent MG G receive unit. The 2 physical data interfaces RS485, RS422 or RS232 are individually selectable by the user with the slide switch mounted from the rear panel. There are also 8 bidirectional alarm inputs provided, each alarm input is typically connected to a contact closure switch. Each alarm output can receive an on/off signal from an MG and is typically used to convey contact closure status. Data Channel Configuration Each low speed data channel provides an RS232, RS422 (full duplex, four wire) or RS485 (half duplex, two wire) interface defined by the corresponding mode switch inside the enclosure. Every data channel as shipped from the factory is set up for RS485 operation unless otherwise requested. The data input for both the RS485 and the RS422 modes detects a tristate input condition by monitoring the differential voltage level across the input. differential level below 600mV positive or negative will be detected as a tristate condition. level above 600mV positive or negative will be detected as a logic 1 or logic 0 respectively. It is important therefore to terminate the RS485 bus or the RS422 input bus using 120Ω if a prebias is present on the RS485 or RS422 bus. large number of third party equipment manufacturers apply a prebias on their RS485 bus. This prebias is applied by pulling one arm of the RS485 bus high (+5 volts) and the other arm low (0 volts) using high value resistors within the third party equipment. In order to ensure that the MG equipment detects a tristate condition, then these resistors should have a value above 5kΩ. If the third party bias resistors are less the 750Ω the bus can be multiple terminated as required to ensure that a tristate level is detected. The system detects a tristate input condition on the data channel bus when in RS485 or RS422 mode. Data Interface Connections Data Channel Connector Pin No. 1 RS485 [switch bottom] IN/OUT (B) RS422 [switch middle] OUT (B) 2 IN/OUT + () OUT + () 3 4 IN (B) 5 IN + () RS232 [switch top] OUT IN Note: () or (B) in brackets in the above table refers to RS485 / RS422 data specification. Data Channel Termination The interface mode RS232, RS422 or RS485 of each data port Data 14, is selected with the corresponding external slide switch D1D4. The actual number of data channels provided on the unit depends upon the MG model. Internal 120Ω termination resistors across IN+ and IN inputs may also be applied when in RS422 or RS485 mode using internal DIP switches P0P3 on the main PCB inside the enclosure. P0P3 may MG Systems Ltd. reserves the right to make changes to this be accurate. No responsibility is assumed by MG for its use. Page 8 of 12 MG Instruction Sheet D doc

9 be accessed by removing the 2 fixing screws in the rear panel and sliding the PCB out of the enclosure. For clarity, in the 3 examples shown below all 4 data ports D1D4 are terminated the same, but each data channel may be configured & terminated independently as required. The 3 examples shown are RS232 (no termination), RS422 (120Ω) or RS485 (120Ω). larm Channel Configuration The MG provides 8 bidirectional contact closure inputs / alarm outputs. Each LRM IN input is via an internal 10kΩ series resistor with a 47kΩ pullup resistor to the internal +3V3 supply. Each LRM OUT output can receive an on/off signal from an MG and is typically used to convey contact closure status. Each alarm output is an NPN open collector circuit with a maximum rated continuous load of 500m / 24Vdc. larm Channel Circuit The output of each alarm channel is an NPN open collector transistor circuit, with an absolute maximum rating of 1 / 60V. There is a common for all alarm channels. MG Systems Ltd. reserves the right to make changes to this be accurate. No responsibility is assumed by MG for its use. Page 9 of 12 MG Instruction Sheet D doc

10 The alarm output circuit is designed for low dc voltage / low current operation and has minimal internal protection. If an alarm output is used to drive an external relay circuit, the external crcuit MUST include a protection (flyback) diode connected across the relay to prevent the high voltage generated from a back EMF causing damage due to the MG output transistor. larm Interface Connections larm Interfaces Connector Pin No. 1 larm IN 14, 58 LRM 1/5 IN larm OUT 14, 58 LRM 1/5 OUT 2 LRM 2/6 IN LRM 2/6 OUT 3 4 LRM 3/7 IN LRM 3/7 OUT 5 LRM 4/8 IN LRM 4/8 OUT udio Channel Connections The MG G provides six bidirectional audio channels. Each audio channel input is a balanced pair and the impedance can be configured as 56kΩ or 600Ω. The input impedance of each audio channel is individually selected using the DIL switch on the front panel. If an audio input is single ended or ground referenced input rather than a differential (balanced) input pair, the udio IN signal should be connected to one of the pins available on the 37way Dtype connector. These inputs are common to all audio channels. Echelon FTT10 Data Channel Configuration The MG provides 2 Echelon FTT10 Data channels. The connection associated with any Data signal signal should be connected to one of the pins available on the 37way Dtype connector. These inputs are common to all audio / data channels. MG Systems Ltd. reserves the right to make changes to this be accurate. No responsibility is assumed by MG for its use. Page 10 of 12 MG Instruction Sheet D doc

11 Data and udio Connections The Bank audio channels and FTT10 data channels pin connections on the rear panel connectors are as follows: Pin No. Description Bank Pin No. Description Bank 1 udio CH1 IN + 20 udio CH1 OUT + /B 2 udio CH1 IN 21 udio CH1 OUT /B 3 udio CH2 IN + 22 udio CH2 OUT + /B 4 udio CH2 IN 23 udio CH2 OUT /B 5 udio CH3 IN + 24 udio CH3 OUT + /B 6 udio CH3 IN 25 udio CH3 OUT /B 7 udio CH4 IN + 26 udio CH4 OUT + /B 8 udio CH4 IN 27 udio CH4 OUT /B 9 28 /B /B udio CH5 OUT + /B 12 udio CH5 IN + 31 udio CH5 OUT /B 13 udio CH5 IN 32 udio CH6 OUT + /B 14 udio CH6 IN + 33 udio CH6 OUT /B 15 udio CH6 IN 34 FTT10 CH7 NET_B 16 FTT10 CH7 NET_B 35 FTT10 CH7 NET_ 17 FTT10 CH7 NET_ 36 FTT10 CH8 NET_B 18 FTT10 CH8 NET_B 37 FTT10 CH8 NET_ 19 FTT10 CH8 NET_ Notes: Bank : Channels 16 are udio and Channels 7 & 8 are FTT10 Data. Bank B : Not Fitted MG Systems Ltd. reserves the right to make changes to this be accurate. No responsibility is assumed by MG for its use. Page 11 of 12 MG Instruction Sheet D doc

12 Physical Information Dimensions Height...112mm Width...170mm (excluding connectors) Depth...21HP Weight grams Mounting Details The MG unit is supplied with a clipon mounting bracket which should be attached to a panel or wall using 2 off 4.0mm screws, see diagram on page 1 for dimensions. The unit is clipped into the mounting bracket, and is then held firmly in position. Safety MG Optical Fibre Products use Class 1 laser systems in accordance with EN :2000. It is always advisable to follow good practice when working with optical fibre systems. This includes: Do not stare with unprotected eyes or with any unapproved collimating device at fibre ends or connector faces, or point them at other people. Use only approved filtered or attenuating viewing aids For other safety issues and advice on good practice associated with optical fibre systems, please see EN :2000 or your local safety officer. Maintenance and Repair There are no user serviceable parts within MG products. See unit data sheet for full specification. In case of problem or failure, please call your local support centre or contact: MG Systems Ltd. at 3 The Omega Centre, Stratton Business Park, Biggleswade, Beds., SG18 8QB, UK. Phone Technical Support +44 (0) (0) techsupport@amgsystems.com MG Systems Ltd. reserves the right to make changes to this be accurate. No responsibility is assumed by MG for its use. Page 12 of 12 MG Instruction Sheet D doc

The AMG5716A9 is designed to be powered using an AMG2001 standalone power supply.

The AMG5716A9 is designed to be powered using an AMG2001 standalone power supply. AMG5716A9 Instruction Manual Single Channel Video Receive Unit with one Bi-directional Data Channel, two Uni-directional Alarms and one Bidirectional Audio Channel for a Singlemode Fibre Link The AMG5716A9

More information

8 Channel Video Transmit Unit with 1 Bi-directional Data Channel for a Singlemode Fibre Link

8 Channel Video Transmit Unit with 1 Bi-directional Data Channel for a Singlemode Fibre Link AMG4783 Instruction Manual 8 Channel Video Transmit Unit with 1 Bi-directional Data Channel for a Singlemode Fibre Link The AMG4783 is a standalone eight channel video transmit unit designed to transmit

More information

Data Insert Unit with 2 Bi-directional Data Channels for a Dual Redundant Singlemode Fibre Ring

Data Insert Unit with 2 Bi-directional Data Channels for a Dual Redundant Singlemode Fibre Ring AMG3703B2DRSF Instruction Manual Data Insert Unit with 2 Bidirectional Data Channels for a Dual undant Singlemode Fibre Ring The AMG3703B2DRSF is a standalone data insert unit designed to transmit and

More information

The AMG5715A1B9 is designed to be powered using an AMG2001 standalone power supply.

The AMG5715A1B9 is designed to be powered using an AMG2001 standalone power supply. AMG5715A1B9 Instruction Manual Single Channel Video Transmit Unit with one Bi-directional Data Channel, two Uni-directional Alarms and one Bidirectional Audio Channel for a Singlemode Fibre Link The AMG5715A1B9

More information

8 Channel Video Transmit Unit with Bi-directional Data Channel and Ethernet for a Multimode Fibre Link

8 Channel Video Transmit Unit with Bi-directional Data Channel and Ethernet for a Multimode Fibre Link AMG4683E Instruction Manual 8 Channel Video Transmit Unit with Bi-directional Data Channel and Ethernet for a Multimode Fibre Link The AMG4683E is a standalone eight channel video transmit unit designed

More information

The AMG5616A6R is designed to plug into an AMG2005 or AMG2009 subrack, which in turn fits into a 19" rack system.

The AMG5616A6R is designed to plug into an AMG2005 or AMG2009 subrack, which in turn fits into a 19 rack system. AMG5616A6R Instruction Manual Single Channel Video Receive Unit with one Bi-directional Data Channel, two Uni-directional Alarms and one Echelon FTT-10A Data Channel for a Multimode Fibre Link The AMG5616A6R

More information

8 Channel Video Transmit Unit with 1 Bi-directional Data Channel for a Singlemode Fibre Link

8 Channel Video Transmit Unit with 1 Bi-directional Data Channel for a Singlemode Fibre Link AMG4783R Instruction Manual 8 Channel Video Transmit Unit with 1 Bi-directional Data Channel for a Singlemode Fibre Link The AMG4783R is a rackmount eight channel video transmit unit designed to transmit

More information

8 Channel Video Receive Unit with 2 Bi-directional Data and Audio Channels plus Ethernet for a Dual Redundant multimode fibre ring.

8 Channel Video Receive Unit with 2 Bi-directional Data and Audio Channels plus Ethernet for a Dual Redundant multimode fibre ring. AMG3684BxEDRSF Instruction Manual 8 Channel Video Receive Unit with 2 Bidirectional Data and Audio Channels plus Ethernet for a Dual undant multimode fibre ring. The AMG3684BxEDRSF is a standalone eight

More information

8 Channel Video Transmit Unit with 9 Bi-directional Data and Audio Channels and Ethernet for a Multimode Fibre Link

8 Channel Video Transmit Unit with 9 Bi-directional Data and Audio Channels and Ethernet for a Multimode Fibre Link AMG4687BER Instruction Manual 8 Channel Video Transmit Unit with 9 Bi-directional Data and Audio Channels and Ethernet for a Multimode Fibre Link The AMG4687BER is a rackmount eight channel video transmit

More information

Single Channel Video Insert Unit with Bi-directional Data Channel for a Dual Redundant fibre ring

Single Channel Video Insert Unit with Bi-directional Data Channel for a Dual Redundant fibre ring AMG3613DRSF Instruction Manual Single Channel Video Insert Unit with Bidirectional Data Channel for a Dual Redundant fibre ring The AMG3613DRSF is a standalone single channel video insert unit designed

More information

4 Channel Video Receive Unit with up to 8 Bi-directional Data and Audio Channels plus Ethernet

4 Channel Video Receive Unit with up to 8 Bi-directional Data and Audio Channels plus Ethernet AMG4748AE Instruction Manual 4 Channel Video Receive Unit with up to 8 Bi-directional Data and Audio Channels plus Ethernet The AMG4748AE is a standalone four channel video receive unit designed to receive

More information

4 Channel Video Receive Unit with Bi-directional Data Channel and Ethernet for a Singlemode Fibre Link

4 Channel Video Receive Unit with Bi-directional Data Channel and Ethernet for a Singlemode Fibre Link AMG4744ER-SF Instruction Manual 4 Channel Video Receive Unit with Bi-directional Data Channel and Ethernet for a Singlemode Fibre Link The AMG4744ER-SF is a rackmount four channel video receive unit designed

More information

Dual Channel Video Insert Unit with Ethernet for a Dual Redundant fibre ring

Dual Channel Video Insert Unit with Ethernet for a Dual Redundant fibre ring AMG3721EDRSF Instruction Manual Dual Channel Video Insert Unit with Ethernet for a Dual Redundant fibre ring The AMG3721EDRSF is a standalone single channel video insert unit designed to transmit two video

More information

4 Channel Video Insert Unit with Ethernet for a Dual Redundant Single Fibre Ring

4 Channel Video Insert Unit with Ethernet for a Dual Redundant Single Fibre Ring AMG3741EDRSF Instruction Manual 4 Channel Video Insert Unit with Ethernet for a Dual Redundant Single Fibre Ring The AMG3741EDRSF is a standalone four channel video insert unit designed to transmit 4 video

More information

4 Channel Video Receive Unit for a Singlemode Fibre Link

4 Channel Video Receive Unit for a Singlemode Fibre Link AMG4742R Instruction Manual 4 Channel Video Receive Unit for a Singlemode Fibre Link The AMG4742R is a rackmount four channel video receive unit designed to receive 4 video signals over one Singlemode

More information

CFO100 Series. User Manual CRT141 & CRR141. CFO141 User Manual, , rev001

CFO100 Series. User Manual CRT141 & CRR141. CFO141 User Manual, , rev001 CFO00 Series User Manual CRT4 & CRR4 CFO4 User Manual, 5930005, rev00 Contents Introduction... Optical Transmitter CRT4 (version B)...2 General...2 Frame Installation...2 Video Input and Indicator Led...2

More information

Connecting a Cisco Input Module

Connecting a Cisco Input Module CHAPTER 4 Overview The optional Cisco Input Module (Figure 4-1) is attached to a Cisco Physical Access Gateway or Cisco Reader Module to provide additional connections for up to ten input devices. Each

More information

OPERATOR MANUAL OSD730 FULL DUPLEX FOUR CHANNEL DIGITAL AUDIO/DATA SYSTEM

OPERATOR MANUAL OSD730 FULL DUPLEX FOUR CHANNEL DIGITAL AUDIO/DATA SYSTEM OPERATOR MANUAL OSD730 FULL DUPLEX FOUR CHANNEL DIGITAL AUDIO/DATA SYSTEM INDEX 1 1. TECHNICAL SUMMARY... 4 1.1 BRIEF DESCRIPTION... 4 1.1.1 OVERVIEW... 4 1.1.2 APPLICATIONS... 4 1.1.3 FEATURES AND BENEFITS...

More information

ICPDAS FSM-510G Series Ethernet Management Switch Quick Start

ICPDAS FSM-510G Series Ethernet Management Switch Quick Start ICPDAS FSM-510G Series Ethernet Management Switch Quick Start Version 1.0, Dec 2014 Overview The Management Ethernet Switch solutions are designed for supporting standard industrial applications. Managed

More information

icex-cmtm General specs and Installation guide

icex-cmtm General specs and Installation guide icex-cmtm General specs and Installation guide 1. General view 2. Specifications 2.1. Common specs: Ethernet 1 x 10/100Base/T, RJ45 connector with traffic and link LED Serial Interface 1 x RS232/485 USB

More information

8~14-Port Managed Ethernet Switch

8~14-Port Managed Ethernet Switch 8~14-Port Managed Ethernet Switch Quick Installation Guide Overview The Managed Ethernet Switch solutions are designed for supporting standard industrial applications. Managed switches are easier to prioritize,

More information

Table of Contents. Functional Description Installation Power Source Power Connection Fiber Connection... 4

Table of Contents. Functional Description Installation Power Source Power Connection Fiber Connection... 4 Instruction Manual MT-946C-SL Four Channel Video Transmitter With One Bi-Directional Multi-Protocol Data Channel And One Bi-Directional Contact Closure Channel 10/02/2012 JPK Table of Contents Functional

More information

MED102A. Industrial Serial to Single-mode Fiber Converter

MED102A. Industrial Serial to Single-mode Fiber Converter MED102A - 0708 pg. 1 / 5 MED102A Industrial Serial to Single-mode Fiber Converter Data Rates up to 115.2 kbps 9 Mile (15 km) Range 10 to 48 VDC Input Voltage Wide Operating Temperature 2000V Isolation

More information

BENCHMARK MEDIA SYSTEMS, INC.

BENCHMARK MEDIA SYSTEMS, INC. BENCHMARK MEDIA SYSTEMS, INC. RLY-106 Instruction Manual 1.0 Introduction...1 2.0 Input and Output Connections...1 2.1 Connection Alternatives...2 3.0 Relay Ratings...2 4.0 Applications...4 4.1 Audio Signal

More information

FSM-510G Series Ethernet Management Switch Quick Start Guide

FSM-510G Series Ethernet Management Switch Quick Start Guide FSM-510G Series Ethernet Management Switch Quick Start Guide Overview The Management Ethernet Switch solutions are designed for supporting standard industrial applications. Managed switches are easily

More information

Connecting a Cisco Reader Module

Connecting a Cisco Reader Module CHAPTER 3 Overview The optional Cisco Reader Module (Figure 3-1) is similar to the Cisco Physical Access Gateway, providing the same ports for Weigand readers and other input and output devices. The Cisco

More information

1 10/100TX FX w/ 1 PoE Injector Industrial Switch. User Manual

1 10/100TX FX w/ 1 PoE Injector Industrial Switch. User Manual 1 10/100TX + 1 100FX w/ 1 PoE Injector Industrial Switch User Manual CE Mark Warning This is a Class-A product. In a domestic environment this product may cause radio interference in which case the user

More information

RTU560 Connections and Settings DIN Rail RTU 560CIG10

RTU560 Connections and Settings DIN Rail RTU 560CIG10 Connections and Settings DIN Rail RTU 560CIG10 Application, characteristics and technical data have to be taken from the hardware data sheet: 560CIG10 1KGT 150 719 Operation The 560CIG10 is a DIN rail

More information

Instruction Manual RR-915C Video Receiver With Bi-directional Multi-Protocol Data And Bi-directional Contact Closure

Instruction Manual RR-915C Video Receiver With Bi-directional Multi-Protocol Data And Bi-directional Contact Closure Instruction Manual RR-915C Video Receiver With Bi-directional Multi-Protocol Data And Bi-directional Contact Closure Copyright 2012, American Fibertek, Inc. 0812JPK INSTALLATION AND OPERATION INSTRUCTIONS

More information

INDUSTRIAL POE SWITCH

INDUSTRIAL POE SWITCH STEP X - Name of Step QUICK START GUIDE LIE1014A, LIE1080A, LIE1082A INDUSTRIAL POE SWITCH 24/7 TECHNICAL SUPPORT AT 877.877.2269 OR VISIT BLACKBOX.COM STEP 1 - Hardware Description LIE1014A LIE1080A TABLE

More information

Serial Data DIN Fiber Link System

Serial Data DIN Fiber Link System USER GUIDE RLH Industries, Inc. The leader in rugged fiber optic technology. U-120 2017A-0420 DIN Fiber Link System COMPACT, RUGGED & TEMPERATURE HARDENED Introduction The DIN Fiber Link system transports

More information

Connecting a Cisco Output Module

Connecting a Cisco Output Module CHAPTER 5 Overview The optional Cisco Output Module (Figure 5-1) is attached to a Cisco Physical Access Gateway or Cisco Reader Module to provide additional connections for up to 8 outputs, each of which

More information

OPERATOR MANUAL OSD157 FIBER OPTIC RS422/RS232 MODEM/MULTIPLEXER

OPERATOR MANUAL OSD157 FIBER OPTIC RS422/RS232 MODEM/MULTIPLEXER / OPERATOR MANUAL OSD157 FIBER OPTIC RS422/RS232 MODEM/MULTIPLEXER PAGE 2 OF 17 INDEX 1 1. TECHNICAL SUMMARY... 4 1.1 BRIEF DESCRIPTION... 4 1.1.1 OVERVIEW... 4 1.1.2 APPLICATIONS... 4 1.1.3 FEATURES AND

More information

4-port 10/100TX + 1 or 2-port 100FX Industrial Switch. User Manual

4-port 10/100TX + 1 or 2-port 100FX Industrial Switch. User Manual 4-port 10/100TX + 1 or 2-port 100FX Industrial Switch User Manual Rev.1.03 Sep-2010 FCC Warning This Equipment has been tested and found to comply with the limits for a Class A digital device, pursuant

More information

Lantech. IPES /100TX with 4 PoE Injectors 24~48VDC Industrial Switch. User Manual

Lantech. IPES /100TX with 4 PoE Injectors 24~48VDC Industrial Switch. User Manual Lantech IPES-0008-4 8 10/100TX with 4 PoE Injectors 24~48VDC Industrial Switch User Manual V1.00 Jun 2010 FCC Warning This Equipment has been tested and found to comply with the limits for a Class-A digital

More information

Instruction Manual RT-91685SL RR-91685SL Sixteen Channel Video Multiplexer With Two Bi-directional Data Channels

Instruction Manual RT-91685SL RR-91685SL Sixteen Channel Video Multiplexer With Two Bi-directional Data Channels Instruction Manual RT-91685SL RR-91685SL Sixteen Channel Video Multiplexer With Two Bi-directional Data Channels Copyright 2007, American Fibertek, Inc. 0501JD Table of Contents Functional Description...3

More information

ADAM-4510 RS-422/RS-485 Repeater ADAM-4510S Isolated RS-422/485 Repeater ADAM-4520 Isolated RS-422/485 Converter Startup Manual

ADAM-4510 RS-422/RS-485 Repeater ADAM-4510S Isolated RS-422/485 Repeater ADAM-4520 Isolated RS-422/485 Converter Startup Manual ADAM-510 RS-/RS-85 Repeater ADAM-510S Isolated RS-/85 Repeater ADAM-50 Isolated RS-/85 Converter Startup Manual Packing List Before you begin installing your module, please make sure that the following

More information

IEC-0101FT Industrial 10/100TX to 100M-FX Slim Type Converter User Manual

IEC-0101FT Industrial 10/100TX to 100M-FX Slim Type Converter User Manual Lantech IEC-0101FT Industrial 10/100TX to 100M-FX Slim Type Converter User Manual FCC Warning This Equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to

More information

MODEL USB-FLEXCOM4. USB to Four RS-232/422/485 Serial Ports and MODEL USB-COM232-4A USB to Four RS-232 Serial Ports USER MANUAL

MODEL USB-FLEXCOM4. USB to Four RS-232/422/485 Serial Ports and MODEL USB-COM232-4A USB to Four RS-232 Serial Ports USER MANUAL Embedded Solutions MODEL USB-FLEXCOM4 USB to Four RS-232/422/485 Serial Ports and MODEL USB-COM232-4A USB to Four RS-232 Serial Ports USER MANUAL FILE: MUSB-FLEXCOM4.B1f ADL Embedded Solutions GmbH, Eiserfelder

More information

ES-562/564U COMBINATION CLOCK/TIMER

ES-562/564U COMBINATION CLOCK/TIMER 142 SIERRA ST., EL SEGUNDO, CA 90245 USA (310)322-2136 FAX (310)322-8127 www.ese-web.com ES-562/564U COMBINATION CLOCK/TIMER OPERATION AND MAINTENANCE MANUAL The ES-562U/564U is a combination six digit

More information

Vorne Industries. 2000S Series Serial Input Alphanumeric Display User's Manual

Vorne Industries. 2000S Series Serial Input Alphanumeric Display User's Manual Vorne Industries 2000S Series Serial Input Alphanumeric Display User's Manual 1445 Industrial Drive Itasca, IL 60143-1849 Telephone (630) 875-3600 Telefax (630) 875-3609 2000S Series Serial Input Alphanumeric

More information

AG300 Family CTL01-3A-03, AMP01-2A-02

AG300 Family CTL01-3A-03, AMP01-2A-02 AG300 Family CTL01-3A-03, AMP01-2A-02 Hardware User's Manual Page 1 Revision control table Version Description Date 1.0 Initial (based on Hardware Manual of previous hardware versions) April 27, 2016 1.1

More information

Quadrature Encoder User's Manual. Specification and Installation Guide. NetLinc, TLAser400 & PTRBe. Oct 2015

Quadrature Encoder User's Manual. Specification and Installation Guide. NetLinc, TLAser400 & PTRBe. Oct 2015 Quadrature Encoder User's Manual Specification and Installation Guide NetLinc, TLAser400 & PTRBe Oct 2015 This document assumes that you have already installed a NetLinc, TLAser400 card or PTRBe, and at

More information

INSTALLATION INSTRUCTIONS. FST-420 Fiber Station Transceiver

INSTALLATION INSTRUCTIONS. FST-420 Fiber Station Transceiver INSTALLATION INSTRUCTIONS MicroComm DXI Fiber Station Transceiver. Intent & Scope This document describes the installation procedure for the Fiber Station Transceivers. 2. Description The Fiber Station

More information

D115 The Fast Optimal Servo Amplifier For Brush, Brushless, Voice Coil Servo Motors

D115 The Fast Optimal Servo Amplifier For Brush, Brushless, Voice Coil Servo Motors D115 The Fast Optimal Servo Amplifier For Brush, Brushless, Voice Coil Servo Motors Ron Boe 5/15/2014 This user guide details the servo drives capabilities and physical interfaces. Users will be able to

More information

USER S MANUAL VER.1. C10D- PARALLEL PORT INTERFACE CARD BOARD Rev. 1

USER S MANUAL VER.1. C10D- PARALLEL PORT INTERFACE CARD BOARD Rev. 1 USER S MANUAL VER.1 C10D- PARALLEL PORT INTERFACE CARD BOARD Rev. 1 MARCH 2018 User s Manual Page i USER'S MANUAL TABLE OF CONTENTS Contents Page # 1.0 OVERVIEW... iii 2.0 FEATURES... iii 3.0 SPECIFICATIONS...

More information

LNP-0602 series. 6-port Industrial PoE+ Unmanaged Ethernet Switches 4*10/100Tx (30W/Port) + 2*100Fx. User Manual

LNP-0602 series. 6-port Industrial PoE+ Unmanaged Ethernet Switches 4*10/100Tx (30W/Port) + 2*100Fx. User Manual LNP-0602 series 6-port Industrial PoE+ Unmanaged Ethernet Switches 4*10/100Tx (30W/Port) + 2*100Fx User Manual FCC Warning This Equipment has been tested and found to comply with the limits for a Class-A

More information

8 10/100/1000T Industrial Switch. User Manual MS655208(X)

8 10/100/1000T Industrial Switch. User Manual MS655208(X) 8 10/100/1000T Industrial Switch User Manual MS655208(X) Content Overview... 1 Introduction... 1 Features... 3 Packing List... 4 Safety Precaution... 4 Hardware Description... 5 Front Panel... 5 Top View...

More information

TCF-142-RM Series Hardware Installation Guide

TCF-142-RM Series Hardware Installation Guide TCF-142-RM Series Hardware Installation Guide Third Edition, March 2015 2015 Moxa Inc. All rights reserved. P/N: 1802001420622 *1802001420622* Overview Introduction The TCF-142-RM series fiber converters

More information

MULTIDYNE INNOVATIONS IN TELEVISION TESTING & DISTRIBUTION INSTRUCTION MANUAL FMX-125

MULTIDYNE INNOVATIONS IN TELEVISION TESTING & DISTRIBUTION INSTRUCTION MANUAL FMX-125 MULTIDYNE INNOVATIONS IN TELEVISION TESTING & DISTRIBUTION INSTRUCTION MANUAL FMX-125 FIBER OPTIC, BI-DIRECTIONAL DATA, CONTACT CLOSURE and AUDIO MULTIPLEXER SYSTEM Revision: 0, Date: October 28, 2013

More information

8-port 10/100TX + 2-Port 10/100/1000T/100/1000 SFP Combo with 8 PoE Injectors Industrial Ethernet Switch User Manual

8-port 10/100TX + 2-Port 10/100/1000T/100/1000 SFP Combo with 8 PoE Injectors Industrial Ethernet Switch User Manual 8-port 10/100TX + 2-Port 10/100/1000T/100/1000 SFP Combo with 8 PoE Injectors Industrial Ethernet Switch User Manual FCC Warning This Equipment has been tested and found to comply with the limits for a

More information

INSTALLATION INSTRUCTIONS. DCC and DCE Installation Instructions. Table of Contents

INSTALLATION INSTRUCTIONS. DCC and DCE Installation Instructions. Table of Contents INSTALLATION INSTRUCTIONS MicroComm DXL DCC and DCE Installation Instructions Table of Contents 1. Intent & Scope 1 2. Description 1 3. DCC Backup Battery 2 4. Field Connections to the DCC 4 5. Field Connections

More information

SCB-C08 USB to RS232/422/485 Converter

SCB-C08 USB to RS232/422/485 Converter SCB-C08 USB to RS232/422/485 Converter USB Interface RS-232 signal RS-422 signal: RS-485 signal: Cable Type Transmission distance Signal LED Direct power from USB port Power consumption: Compliant with

More information

RS 485 Mini Modbus 1AO

RS 485 Mini Modbus 1AO RS 485 Mini Modbus 1AO Version 1.0 14/08/2014 Manufactured for Thank you for choosing our product. This manual will help you with proper support and proper operation of the device. The information contained

More information

EasySYNC Ltd. USB to Serial Converters Manual

EasySYNC Ltd. USB to Serial Converters Manual EasySYNC Ltd Document Reference No.: ES_000061 Issue Date: 2011-08-23 The ES-U-xxxx-x adapters are a series of USB Serial Converters from EasySYNC Ltd. They provide a simple method of adapting legacy RS-232

More information

TN-5308 Quick Installation Guide

TN-5308 Quick Installation Guide TN-5308 Quick Installation Guide Moxa ToughNet Switch Edition 6.0, February 2017 Technical Support Contact Information www.moxa.com/support Moxa Americas: Toll-free: 1-888-669-2872 Tel: 1-714-528-6777

More information

Specifications MLC Plus 50/100/200 Series

Specifications MLC Plus 50/100/200 Series Specifications MLC Plus 50/100/200 Series Memory SDRAM... 512 MB Flash... 512 MB Software and control options Software... Extron Global Configurator Plus and Professional for Windows Control options...

More information

EasySYNC Ltd. USB to Serial Converters Manual

EasySYNC Ltd. USB to Serial Converters Manual EasySYNC Ltd Document Reference No.: ES_000061 Issue Date: 2011-01-26 The ES-U-xxxx-x adapters are a series of USB Serial Converters from EasySYNC Ltd. They provide a simple method of adapting legacy RS-232

More information

Intellia Input /Output modules for FX fire detection system

Intellia Input /Output modules for FX fire detection system Intellia Input /Output modules for FX fire detection system Fire protection systems can be engineered simply and effectively without the need for custom-designed equipment. The Intellia Input/output-modules

More information

WP100 Platform. control systems. CPU module for small and medium sized wind turbines. Safe operation in harsh environments

WP100 Platform. control systems. CPU module for small and medium sized wind turbines. Safe operation in harsh environments CPU module for small and medium sized wind turbines Safe operation in harsh environments Maintenance free - no fans and no batteries that need replacement Advanced event based data logging and storage

More information

FVT/FVR20D2I1C4E INSTALLATION AND OPERATION MANUAL

FVT/FVR20D2I1C4E INSTALLATION AND OPERATION MANUAL 2-CHANNEL 10-BIT DIGITALLY ENCODED VIDEO + 2 BI-DIRECTIONAL DATA + AIPHONE INTERCOM + 4 CONTACT CLOSURE + 100MB ETHERNET + REDUNDANT POINT-TO-POINT DUAL SFP OPTICAL PORTS The series utilize 10-bit digital

More information

USER S MANUAL VER.1. C10- PARALLEL PORT INTERFACE CARD BOARD Rev. 11

USER S MANUAL VER.1. C10- PARALLEL PORT INTERFACE CARD BOARD Rev. 11 USER S MANUAL VER.1 C10- PARALLEL PORT INTERFACE CARD BOARD Rev. 11 FEBRUARY, 2017 User s Manual Page i USER'S MANUAL TABLE OF CONTENTS Contents Page # 1.0 OVERVIEW... iii 2.0 FEATURES... iii 3.0 SPECIFICATIONS...

More information

RibEye Multi-Point Deflection Measurement System 3-Axis Version for the SIDIIs ATD Hardware Manual for Model January 2010

RibEye Multi-Point Deflection Measurement System 3-Axis Version for the SIDIIs ATD Hardware Manual for Model January 2010 USER S MANUAL RibEye Multi-Point Deflection Measurement System 3-Axis Version for the SIDIIs ATD Hardware Manual for Model 7715 15 January 2010 Boxboro Systems, LLC 978-257-2219 www.boxborosystems.com

More information

Industrial Slim Type Fast Ethernet Rail Switch

Industrial Slim Type Fast Ethernet Rail Switch Industrial Slim Type Fast Ethernet Rail Switch Version 1.0 May, 2008. Table of Content Overview...2 1.1 About the 505710 / 505628 unmanaged Industrial Switch...2 1.2 Hardware Features...2 Hardware Installation...3

More information

EDS-G308 Series Quick Installation Guide

EDS-G308 Series Quick Installation Guide EDS-G308 Series Quick Installation Guide Moxa EtherDevice Switch Edition 6.1, September 2017 Technical Support Contact Information www.moxa.com/support Moxa Americas: Toll-free: 1-888-669-2872 Tel: 1-714-528-6777

More information

Product Specification. 10Gb/s 10km Datacom XFP Optical Transceiver FTRX-1411D3

Product Specification. 10Gb/s 10km Datacom XFP Optical Transceiver FTRX-1411D3 Product Specification 10Gb/s 10km Datacom XFP Optical Transceiver FTRX-1411D3 PRODUCT FEATURES Supports 9.95Gb/s to 10.5Gb/s bit rates Hot-pluggable XFP footprint Maximum link length of 10km Uncooled 1310nm

More information

10/100/1000T to Mini-GBIC Industrial Switch Converter 10/100/1000T to 1000SX/LX Industrial Switch Converter. AMG9011G-H (-40 to 75C) User Manual

10/100/1000T to Mini-GBIC Industrial Switch Converter 10/100/1000T to 1000SX/LX Industrial Switch Converter. AMG9011G-H (-40 to 75C) User Manual 10/100/1000T to Mini-GBIC Industrial Switch Converter 10/100/1000T to 1000SX/LX Industrial Switch Converter AMG9011G-H (-40 to 75C) User Manual www.amgsystems.com Content Overview...1 Introduction... 1

More information

Click-A-Tune. User Manual

Click-A-Tune. User Manual Contents Configuring the...2 Transferring data to the...2 with switch configuration...3 with switch matrix up to 3 switches...4 Changing the playback volume...5 Connections... Power requirements (Vin)...

More information

General. 5 and 8 port Fast Ethernet switches. 6 and 8 Port Gigabit Ethernet switches. Switches with fiber uplink

General. 5 and 8 port Fast Ethernet switches. 6 and 8 Port Gigabit Ethernet switches. Switches with fiber uplink Entry Line Industrial Gigabit Ethernet Switch 4x 10/100/1000Base-T with PoE+, 1x 10/100/1000Base-T or 100/1000Base-X Combo Port, 1x 100/1000Base X SFP Slot General The IP protocol has already left the

More information

LNP series. 5-port Industrial PoE+ Unmanaged Ethernet Switches 4*10/100Tx (30W/Port) + 1*10/100Tx, 12~36VDC Input.

LNP series. 5-port Industrial PoE+ Unmanaged Ethernet Switches 4*10/100Tx (30W/Port) + 1*10/100Tx, 12~36VDC Input. LNP-0500-24 series 5-port Industrial PoE+ Unmanaged Ethernet Switches 4*10/100Tx (30W/Port) + 1*10/100Tx, 12~36VDC Input User Manual FCC Warning This Equipment has been tested and found to comply with

More information

Manual Industry Interfaces

Manual Industry Interfaces Manual Industry Interfaces W&T Release. Type 0, 0 0, 00 0, 0 0, 0 Industry Interfaces 0/0 by Wiesemann & Theis GmbH Subject to errors and changes: Since we can make mistakes, none of our statements should

More information

One and four channel video links

One and four channel video links User manual One and four channel video links CFO First Mile series consist of fibre optic modems which provide a high quality and lossless video transmission for variety of CCTV applications. CFO160 1

More information

10/100TX to 100FX w/ 1 PoE Injector Industrial Media Converter User Manual

10/100TX to 100FX w/ 1 PoE Injector Industrial Media Converter User Manual 10/100TX to 100FX w/ 1 PoE Injector Industrial Media Converter User Manual v1.02 FCC Warning This Equipment has been tested and found to comply with the limits for a Class-A digital device, pursuant to

More information

RTU560 Remote Terminal Unit Connections and Settings

RTU560 Remote Terminal Unit Connections and Settings Remote Terminal Unit Connections and Settings Communication Unit 560CMG10 Application, characteristics and technical data have to be taken from the hardware data sheet: 560CMG10 1KGT 150 645 Operation

More information

MUSIC SERVER SERVICE MANUAL CONTENTS

MUSIC SERVER SERVICE MANUAL CONTENTS MUSIC SERVER CONTENTS Performance Specifications... 2 Notes... 2 Safety Information... 2 Rear Panel... 3 Section Location... 3 Block Diagram... 4 Interconnection Diagram... 5 Front Panel Schematic and

More information

INDUSTRIAL 1000BASE-T TO 1000BASE-X MEDIA CONVERTERS. KCD-400 Series. Installation Guide

INDUSTRIAL 1000BASE-T TO 1000BASE-X MEDIA CONVERTERS. KCD-400 Series. Installation Guide INDUSTRIAL 1000BASE-T TO 1000BASE-X MEDIA CONVERTERS KCD-400 Series Installation Guide DOC.060227-KCD-400-1- (C) 2005 KTI Networks Inc. All rights reserved. No part of this documentation may be reproduced

More information

ROCKETLINX ES7110 ES7110/ES7110-VB

ROCKETLINX ES7110 ES7110/ES7110-VB ROCKETLINX ES7110 ES7110/ES7110-VB QUICK INSTALLATION GUIDE 2000550 Rev E Release Date - August 2015 INTRODUCTION The RocketLinx ES7110 series is an industrial Power over Ethernet (PoE) switch with eight

More information

SPECTRA ENGINEERING PTY LTD

SPECTRA ENGINEERING PTY LTD Serial Splitter Unit SPECTRA ENGINEERING PTY LTD MXSSU MXSSU Spectra Engineering Pty Ltd ABN 0 Trade Road Malaga Western Australia 00 Tel: +-- Fax: +-- Email: info@spectraeng.com.au Web: www.spectraeng.com.au

More information

CMU 100 RS485 to 7x, 6x, 5x, 4x Multimode Fiber Optic Star Coupler User Manual

CMU 100 RS485 to 7x, 6x, 5x, 4x Multimode Fiber Optic Star Coupler User Manual CMU 100 RS485 to 7x, 6x, 5x, 4x Multimode Fiber Optic Star Coupler User Manual CMU 100 / 2.5.6.6.6.6.6.6.6 12, CMU 100 / 8.5.6.6.6.6.6.6.6 12, CMU 100 / 2.5.6.6.6.6.6.6 12, CMU 100 / 8.5.6.6.6.6.6.6 12,

More information

ICD105A 1008 page 1/ r001 ICD105A. Industrial RS-232 to RS-422/485 Converter

ICD105A 1008 page 1/ r001 ICD105A. Industrial RS-232 to RS-422/485 Converter ICD105A 1008 page 1/5 7319 r001 ICD105A Industrial RS-232 to RS-422/485 Converter Data Rates up to 115.2 Kbps 10 48 VDC Input Power Range Wide Operating Temperature 3-Way 2000V Optical Isolation Modbus

More information

4 10/100/1000T Mini-GBIC with 4 IEEE 802.3at High Power PoE Industrial Wide Temperature Switch. User Manual SISTP LRT

4 10/100/1000T Mini-GBIC with 4 IEEE 802.3at High Power PoE Industrial Wide Temperature Switch. User Manual SISTP LRT 4 10/100/1000T + 2 1000 Mini-GBIC with 4 IEEE 802.3at High Power PoE Industrial Wide Temperature Switch User Manual V1.0 September-2013 FCC Warning This Equipment has been tested and found to comply with

More information

ICF-1150 Series Quick Installation Guide

ICF-1150 Series Quick Installation Guide ICF-1150 Series Quick Installation Guide Second Edition, March 2012 2012 Moxa Inc. All rights reserved. P/N: 1802011500011 Overview Introduction The ICF-1150 series fiber converters are equipped with a

More information

6 Port Unmanaged Industrial Gigabit Ethernet Switch w/ 4 PoE+ Ports and Voltage Regulation - DIN Rail / Wall-Mountable

6 Port Unmanaged Industrial Gigabit Ethernet Switch w/ 4 PoE+ Ports and Voltage Regulation - DIN Rail / Wall-Mountable 6 Port Unmanaged Industrial Gigabit Ethernet Switch w/ 4 PoE+ Ports and Voltage Regulation - DIN Rail / Wall-Mountable Product ID: IES61002POE The IES61002POE 6-Port Industrial PoE+ switch lets you connect

More information

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description Vision OPLC V130 COM Modules: V100-17-CAN, V100-17-RS4/X, V100-17-ET2 This guide shows you how to install an additional communication module in a V130 controller. Instructions and technical specifications

More information

PCL channel Isolated Digital I/O Card

PCL channel Isolated Digital I/O Card PCL-730 32-channel Isolated Digital I/O Card Copyright This documentation is copyrighted 1996 by Advantech Co., Ltd. All rights are reserved. Advantech Co., Ltd. reserves the right to make improvements

More information

Sierra Radio Systems. HamStack. Project Board Reference Manual V1.0

Sierra Radio Systems. HamStack. Project Board Reference Manual V1.0 Sierra Radio Systems HamStack Project Board Reference Manual V1.0 Welcome HamStack Project Board Reference Manual Revision 1.0.3 2011 George Zafiropoulos, KJ6VU and John Best, KJ6K This guide provides

More information

5 10/100TX w/ 4 PoE Injector Industrial Switch. User Manual

5 10/100TX w/ 4 PoE Injector Industrial Switch. User Manual 5 10/100TX w/ 4 PoE Injector Industrial Switch User Manual V1.01 Nov-2010 CE Mark Warning This is a Class-A product. In a domestic environment this product may cause radio interference in which case the

More information

ABB Drives. User s Manual Modbus Adapter Module FMBA-01

ABB Drives. User s Manual Modbus Adapter Module FMBA-01 ABB Drives User s Manual Modbus Adapter Module FMBA-01 Modbus Adapter Module FMBA-01 User s Manual 3AFE68586704 REV A EN EFFECTIVE: 27.06.2005 2005 ABB Oy. All Rights Reserved. 5 Safety instructions

More information

Device Server for the conversion of serial interfaces (RS-232/422/485) to IP.

Device Server for the conversion of serial interfaces (RS-232/422/485) to IP. Manual Entry Line Industrial Gigabit Ethernet Switch 4x 10/100/1000Base-T, 1x SFP Ports MICROSENS General The IP protocol has already left the in-house environment and is going to take all remaining communication

More information

MODEL USB-FLEXCOM4 USB to Four RS-232/422/485 Serial Ports. and. MODEL USB-COM232-4A USB to Four RS-232 Serial Ports USER MANUAL

MODEL USB-FLEXCOM4 USB to Four RS-232/422/485 Serial Ports. and. MODEL USB-COM232-4A USB to Four RS-232 Serial Ports USER MANUAL 10623 Roselle Street, San Diego, CA 92121 (858) 550-9559 Fax (858) 550-7322 contactus@accesio.com www.accesio.com MODEL USB-FLEXCOM4 USB to Four RS-232/422/485 Serial Ports and MODEL USB-COM232-4A USB

More information

SBR The Chameleon Converter II

SBR The Chameleon Converter II SBR 0981 The Chameleon Converter II Security Engineering 2003-2015 The Chameleon converter II: Concept: The Chameleon converter II is a one-fits-all protocol conversion PCB that is designed to host one

More information

16E1 + 1Ethernet Fiber Optical Multiplexer

16E1 + 1Ethernet Fiber Optical Multiplexer User s Manual To users: Thank you for using our products. Before using, please read this Reference Manual carefully, and keep properly. Alarm 1. This product cannot be caught in or be affected with damp,

More information

MOXA Industrial Media Converter

MOXA Industrial Media Converter MOX Industrial Media Converter IMC-1 Hardware Installation Guide First Edition, September 005 Moxa Networking Co., Ltd. Tel: +886--910-130 Fax: +886--910-131 www.moxa.com support@moxanet.com (Worldwide)

More information

Specifications MLC 226 Series

Specifications MLC 226 Series Specifications MLC 226 Series IP Intercom Connection type (IPI MLC)... RJ-45 jack for CAT 5/5e/6 cable Audio Frequency response... 20 Hz to 3.3 khz, ±1 db Audio processing Audio format... PCM, µ-law companded

More information

ES-362U PRESETTABLE MASTER TIMER

ES-362U PRESETTABLE MASTER TIMER 142 SIERRA ST., EL SEGUNDO, CA 90245 USA (310)322-2136 FAX (310)322-8127 www.ese-web.com ES-362U PRESETTABLE MASTER TIMER OPERATION AND MAINTENANCE MANUAL The ES-362U is a four digit, presettable 100 minute

More information

Quick Start Guide. SEB-710 I/O Expansion board. Introduction

Quick Start Guide. SEB-710 I/O Expansion board. Introduction SEB-710 I/O Expansion board Revision 1.0 - (March, 2011) Saflec Systems (Pty) Ltd Quick Start Guide Introduction The SEB-710 is an I/O expansion device for additional inputs and outputs. It has eight relay

More information

RS-485 Fiber-Optic Link RS-485 to Multi-Mode Fiber-Optic converter ST Fiber Connectors DIN Rail Mount

RS-485 Fiber-Optic Link RS-485 to Multi-Mode Fiber-Optic converter ST Fiber Connectors DIN Rail Mount Fiber-Optic Link to Multi-Mode Fiber-Optic converter ST Fiber Connectors DIN Rail Mount 101-0079 Installation Operation & Specifications Manual Auto-direcon control Supports BAUD rates up to 115,200 Fiber

More information

IMC-21GA Quick Installation Guide

IMC-21GA Quick Installation Guide IMC-21GA Quick Installation Guide Moxa Industrial Media Converter Edition 4.0, June 2017 Technical Support Contact Information www.moxa.com/support Moxa Americas: Toll-free: 1-888-669-2872 Tel: 1-714-528-6777

More information

IMC-21A Quick Installation Guide

IMC-21A Quick Installation Guide IMC-21A Quick Installation Guide Moxa Industrial Media Converter Edition 5.0, February 2017 Technical Support Contact Information www.moxa.com/support Moxa Americas: Toll-free: 1-888-669-2872 Tel: 1-714-528-6777

More information

PTC-101-M12 Hardware Installation Guide

PTC-101-M12 Hardware Installation Guide PTC-101-M12 Hardware Installation Guide Moxa Industrial Media Converter Third Edition, May 2014 2014 Moxa Inc. All rights reserved. P/N: 1802001016021 Overview The PTC-101-M12 industrial media converter

More information