Industrial Control Relays Relays and terminal module RS type
|
|
- Joshua Gregory
- 5 years ago
- Views:
Transcription
1 Relaysandterminal module Relays-and-terminal module RS, N A very compact, space-saving terminal module containing four or six relays with one NO contact. Features The RS series relays-and-terminal module consists of four or six plug-in relays (RB0, NO contact or RB0, NC contact) and a terminal module with screw terminals. This relaysand-terminal module is ideal for interfacing electronic control devices (such as PLCs or photoelectric sensors) with output devices (such as solenoid valves and magnetic contactors). The use of ultra-small, high-sensitive relays has realized a compact size of Specifications Type mm wide and mm long, including screw terminals (RSN type). Input terminals are located in the upper part and output terminals in the lower part of the module to separate them from each other, thereby making wiring easy. The terminal module uses RB0 or RB0 card relays. For replacement, please specify the card relay type and coil voltage. Built-in coil-surge suppression diodes and operation indicator LEDs simplify circuit design and maintenance. The module is quickly-mountable on a D mm rail. The RSN module includes two standard accessory jumper plates, which are convenient for common wiring of terminals. RSN, RS, RS, RSN, RSNP Contact NO NC Contact resistance 0mΩ or less (before use) Contact material Silver alloy (Au-plated) Min. operating voltage and current 0.V DC, ma V DC, ma Rated thermal current A Max. make/break current 0V AC, A 0V AC, A 0V DC, A 0V DC, A Operating time 0ms. or less at rated voltage Release time 0ms. or less at rated voltage Insulation resistance 00MΩ (at 00V DC megger) Dielectric strength: Between contact and coil 000V AC minute Between contacts of same pole 0V AC minute Between contacts of different pole 000V AC minute Between coils of different pole 00V AC minute Vibration: Malfunction durability 0 to Hz, mm double amplitude Mechanical durability 0 to Hz,.mm double amplitude Shock: Malfunction durability 00m/s Mechanical durability 000m/s Durability: Mechanical 0 million operations Electrical See page 0/ Ambient temperature to C (no icing) RSN Type number nomenclature RS N-DE P KKD0-0 side polarity (For RSN type only) NPN type (common): Blank PNP type (-common): P Rated voltage DC:.V DC DY: V DC DA: V DC DD: V DC DB: V DC DE: V DC Output contact N: NO : NONC : NONC N: NO Relay and terminal Relay remover To remove a relay from the terminal module, use the type TY relay remover sold separately. Pull the relay in a direction perpendicular to the terminal module surface. Incorrectly removing or mounting a relay may damage the relay pins and pin jacks of the module. Operating coil of card relays Relay Coil Pick-up Drop-out Power Coil voltage voltage voltage consumption resistance RB0.V DC 0% or less % or more 00mW 00Ω (NO) V DC of rated coil of rated coil Ω V DC voltage voltage 0Ω V DC 0Ω V DC 0Ω V DC 0Ω RB0.V DC 0mW Ω (NC) V DC 0Ω V DC 00Ω V DC Ω V DC 00Ω V DC 00Ω TY(RZA) Ordering information Specify the following:. Type number AF-0 0/
2 Relaysandterminal module Electrical durability NO output contact Voltage Make Break Operations current (A) current (A) 0V AC (inductive load) 0 (cos ø = 0.) (cos ø = 0.0.) 00,000 0V AC (resistive load) (cos ø =.0) (cos ø =.0) 0,000 V DC (inductive load) (T= ms) (T= ms) 0,000 V DC (resistive load) (T= ms or less) (T= ms or less) 00,000 NC output contact Voltage Make Break Operations current (A) current (A) 0V AC (resistive load) (cos ø = ) (cos ø = ) 00,000 V DC (resistive load) (L/R= 0ms) (L/R= 0ms) 0,000 0 Dimensions, mm RSN (RSA, RSD) Wiring diagrams RSN Finger protection cover RZN.. (Rail height ) (Rail height.). Internal wiring RZN ø. (). Operation indicator 0 D mm rail See page 0/. M. x. Jumper RSN (RSA, RSD) RSN.. (Rail height ) (Rail height.). Internal wiring Operation indicator 0 D mm rail M. x. 0/
3 Relaysandterminal module Relays-and-terminal module RS -point relays-and-terminal module with the smallest width in its class Features Most compact in its class Outside dimensions are 0mm (W), mm (D), and mm (H). The width is the smallest in this class. Push-to-set (quick-connect) terminals for easy wire connection A unique terminal structure enables quick and easy crimp terminal connections without removal of screws. (No more lost screws) Clear LEDs indicate relay output status. Each relay has an LED to indicate its ON/OFF status. A surge suppressing diode is provided for each relay coil. Terminal cover with label for marking device Nos. Built-in relay remover D rail quick mount and panel-surface mount using screws Type number nomenclature RS E - DE 0 P RS AF- Ordering information Specify the following:. Type number Relays and terminal No. of poles : -pole Input/output E: DC input Blank: Relay output side polarity Blank: NPN type (common) P: PNP type (-common) maker 0: Hirose Electric Co., Ltd. Rated voltage DY: V DC DE: V DC Types Type Input/output No. of poles Rated voltage side polarity RS- 0 Output (NO ) V DC NPN type (common) RS- 0P V DC PNP type (-common) RSE- 0 Input NPN type (common) Note: Enter the rated voltage code in the Ratings Operating coil mark as follow. V DC: DY, V DC: DE Rated voltage Rated operational Coil resistance Pick-up Drop-out Power consumption current (ma) (Ω) voltage voltage (W) V DC.,0±0% 0% or less 0% or more 0./NO contact V DC 0 ±0% of coil rated voltage of coil rated voltage./no contacts Note: An LED flows approx. ma. To calculate the power requirements, calculate the total coil and LED currents of all relays installed in the terminal module. Contact Terminal relay type RS (output) RSE (input) Rated current 0V AC (Res. load) A 0V AC (Ind. load) A V DC (Res. load) A A V DC (Ind. load) A A Rated thermal current* A A Electrical durability (operations) 00,000 at 00V AC, A 00,000 at V DC, A Mechanical durability (operations) 0,000,000 Note * The contact current rating of the RB0 relay used in this module is A. The thermal current rating of this terminal module, however, is A or A due to limitations of the terminal module (RS) rating. 0/
4 Relaysandterminal module Performance data Operating time 0ms or less Release time 0ms or less Vibration Malfunctions durability 0Hz mm double amplitude Mechanical durability 0Hz mm double amplitude Operating ambient temperature - C(no icing) Operating ambient humidity -%RH Terminal screw size M Tightening torque 0.0.N m Mounting Rail mounting (screw mounting also available) Applicable crimp terminal R. (Max. mm wide) Applicable wire size Max. φ. LED color Operation indication Red Coil surge suppressor Power source indication Insulation resistance (before use) Green Diode 00MΩ (00V DC megger) Dielectric Between contact and coil 000V AC, minutes strength Between open contacts 0V AC, minutes Between contacts of opposite 000V AC, minutes polarity Mass 00g 0 Cable types Type Cable length Type (Ordering code) Cable with applicable crimp,000mm RS0B-00 terminal (ring),000mm RS0B-00,000mm RS0B-00 Cable FUJI ELECTRIC FA,000mm RS0F-00 with connectors,000mm RS0F-00 (:) PLC,000mm RS0F-00 Mitsubishi electric,000mm RS0M-00 Corp. PLC,000mm RS0M-00,000mm RS0M-00 OMRON PLC,000mm RS0T-00,000mm RS0T-00,000mm RS0T-00 Cable Multicore cable,000mm AUX0-0(LP-0) with connectors,000mm AUX0-0(LP-0) (:),000mm AUX0-0(LP-0) Flat cable,000mm,000mm,000mm Note: The ordering codes of the cables with connectors (:) differ from the type. The ordering codes are in parentheses. AUX0-0(LP-0) AUX0-0(LP-0) AUX0-0(LP-0) 0/
5 Relaysandterminal module Wiring diagrams RS-DE0 (Output, NPN type) RS-DE0P (Output, PNP type) 0 Terminal brok Terminal brok VCC 0 F GND F E E D D C B C B A A pin 0 0 GND 0 VCC GND pin 0 0 VCC GND VCC RSE-DE0 (Input, NPN type) 0 Terminal block VCC 0 F pin 0 0 GND E D C B A 0 VCC GND 0/0
6 Relaysandterminal module How to use a push-to-set terminal (Quick-connect terminal) Lift the screw head up with a screw driver tip. Insert the crimp terminal of the wire into the slot under the screw. Use a screwdriver to tighten the screw. 0 Dimensions, mm Power on indicator Green 0 Operating status indicator Red 0 (Mounting rail height ). (Mounting rail height.) () Panel drilling M x HIFCA-0PA-.DSA. mm D rail -ø. (for screw mounting)... 0/
7 Relaysandterminal module Relays-and-terminal module with SSR output Features SSR output (AC and DC) Provided with a miniature SSR with the same dimensions as the RBseries miniature card relay resulting in a longer service life and making it ideal for highly frequent switching. Slim -mm body Slim -mm design for all models up Type number nomenclature RS A - DE Rated voltage DY: V DC DB: V DC DE: V DC Output A: SSR (AC output) D: SSR (DC output) Relays and terminal No. of poles : -pole : -pole : -pole to -pole models allowing significant space savings within the panel. Both surface mounting and D rail mounting are possible Provided with operation indicators Easy relay maintenance with special socket (type TP0) RZN finger protector also available. (Sold separately.) Types Type (Ordering code) Replace the mark by the rated voltage (code) Output RSA- V DC: DY, V DC: DB SSR (AC output) RSD- V DC: DE SSR (DC output) RSA- SSR (AC output) RSD- SSR (DC output) RSA- SSR (AC output) RSD- SSR (DC output) Ordering information Specify the following:. Type number Specifications Type RSA, RSA RSA RSD, RSD RSD DC input-ac output DC input-dc output Main Rated insulation voltage 0V 0V circuit Rated voltage Vn 000V AC V DC (output) Operating voltage range 00V AC..V DC Rated frequency 0/0Hz - Rated thermal current 0.A 0.A 0.A 0.A Leakage current at OFF state (max) ma or less 0.mA or less Minimum load current 0mA ma Voltage drop at ON state (max).v or less V or less Zero-cross function Surge-on current A (0ms, shot) A (0ms, shot) Control Isolation method Phototriac Photocoupler circuit Rated voltage Vn V DC V DC V DC V DC V DC V DC (input) Operating voltage range..v DC..V DC..V DC..V DC..V DC..V DC Pick-up voltage 0%Vn or less 0%Vn or less Drop-out voltage 0%Vn or more 0%Vn or more Input impedance Approx.0Ω Approx.kΩ Approx..kΩ Approx.0Ω Approx.kΩ Approx..kΩ General Ambient temperature (operate) - C (no icing) - C (no icing) specification Ambient temperature (storage) - 0 C (no condensation) - 0 C (no condensation) Relative humidity %RH %RH Dielectric strength Between input and output terminals 000V AC min. Between input and output terminals 000V AC min. Insulation resistance Over 00MΩ at 00V DC megger Over 00MΩ at 00V DC megger Operating time ms or less ms or less Release time / cycle ms or less ms or less Vibration resistance 0 Hz,.mm double mm 0 Hz,.mm double mm amplitude amplitude Shock resistance 00m/s 00m/s Mass Approx. g Approx. 00g Approx. g Approx. 00g 0/
8 Relaysandterminal module Dimensions, mm RSA, D RSA, D Same as RSN Same as RS See page 0/ See page 0/ Wiring diagrams RSA RSD RSA RSA RSD 0 0 RSD RSA, D Same as RSN See page 0/ RZ finger protection cover for RS series relays-and-terminal module Features Ensures safety and prevent dust This cover prevent persons from touching, by mistake, live conductor parts of the terminal module and receiving an electric shock. The cover KKD0-0 also protect relays from dust. Hold the relay remover The cover surface has two holes to hold the type TY relay remover. When the remover is not being used, it can be attached to the cover so that it is not lost. The cover is quick-mount The cover can be quickly mounted on or removed from the TP0 socket used with RS series relays-and-terminal module. The cover can be mounted at any time The cover can be mounted on or removed from the socket at any time before or after wiring the terminals. Crimp terminal is also available It is possible to use a crimp terminal as well as terminal jumper for wiring. Type Type RZN Used with RSN, -pole relays-and-terminal module RSN, -pole relays-and-terminal module 0 0 Terminal block 0 Terminal block VCC 0 F E VCC 0 F E Dimensions, mm D C B A D C B A ø.. () pin GND VCC GND pin GND VCC GND Mass: Approx..g 0/
9 Relaysandterminal module Notes on use Mounting direction This product can be mounted in any direction. However, to mount the product in a direction which each relay is horizontal, it is recommended that the product will be mounted so that the cable connector is positioned at the bottom. This position ensures the optimal vibration resistance of the relay. Use optional end clamps (TS-XT) as needed to prevent the relays-andterminal module from failing off and to ensure correct positioning of the relays. Installing and removing a relay Installing a relay: While holding the relay perpendicular to the socket, insert the relay into the socket as shown below. Incorrect insertion may bend the relay terminals or damage the socket. Removing a relay: Use the accessory remover to remove the relay from the socket. side Correct Incorrect Component relay This product uses the RB0 series of card relays as components. When replacing a relay, use a relay of the same type with the same voltage rating as that of the original. Make spaces between nearby devices When mounting this product on a panel, be sure there is adequate space between the product and nearby devices and cable ducts, as shown in the figure at right. This space enables operation of the connectorejecting levers. mm Applicable cable connectors Use Fuji Electric s connectors for cable connections (optional). Use of any other connector may damage the module connector or cause faulty connections. 0mm 0/
PC RELAY TERMINAL/ PC TERMINAL
Input points Output points PC Relay (PC relays mounted) PC Input points Output points Input points Output points Input points Output points Input points Output points Output points ORDERING INFORMATION
More informationCombine Relays and P7TF Block Bases to match your application requirements. Use the table below to configure Relay Blocks.
9 Relay I/O Block Reduces Wiring within the Control Panel and Reduces Installation Time 1 Compact 16-pt models: 182 W l 85 D l 68 H mm; 8-pt block width is 102 mm 1 Can be connected to the PLC with a connecting
More informationModel Number Structure
Solid State Relays with Failure Detection Function G3PC CSM_G3PC_DS_E_1_1 Refer to Safety Precautions for All Solid State Relays. Detects failures in SSR used for heater temperature control and simultaneously
More information(Applicable output load) to 264 (see note 2) (see note 1) (2Aat75to264VAC) G3R-202SLN-US PCB Yes 2 A at 100 to 120 VDC. (2 A at 75 to 132 VDC)
Solid-state Relay Compact SSRs Ideal for Built-in Applications Vertical, compact SSRs with an operation indicator offered in versatile variations. Can be mounted side by side with an electromagnetic relay
More informationModel Number Structure
Solid State Relays with Failure Detection Function G3PC Detects failures in SSR used for heater temperature control and simultaneously outputs alarm signal. This SSR supports the safe design of heater
More informationG3PC. Model Number Structure. Solid State Relays with Failure Detection Function. Model Number Legend
Solid State Relays with Failure Detection Function G3PC Refer to Warranty and Application Considerations (page 1), Safety Precautions (page 4), and Technical and Safety Information (page 6). Detects failures
More informationTransistor drive 2c/4c 5A slim power relays
Transistor drive c/c 5A slim power relays NC RELAYS NC Flat type () NC (Plug-in type) RoHS compliant NC Flat type () NC () FEATURES 1. Compact, slim design Use of high-performance flat electromagnetic
More informationUltra Slim Relays 24
Ultra Slim Relays 24 Technical Data... 1 Specifications.2 Model Number Structure - Relays...3 Model Number Selection...4 Accessories...5 Safety Precautions...6 Ultra Slim Relays WERNER`s embody the latest
More informationBulletin 700-SH Solid-State Relays. Overview/Product Selection. Bulletin 700-SH. Product Selection
Overview/Product Selection Bulletin 700-SH 40 A (resistive) Max. Continuous (Output) Current with Heat Sink 264V AC or 528V AC Max. Voltage Range Options 5 24V DC, 100 120V AC, 200 240V AC Control Input
More informationVaristor installation. Input logic. Voltage of relay coil
Features For driving various loads using PLC output signals Easily check operation status and high luminance LED turns on with input signals Choose various relays depending on each load voltage or current
More informationNote: Each relay to be mounted must incorporate a coil that has proper specifications within the maximum rated voltage range.
I/O Block Base G7A Reduces Wiring while Providing I/O Flexibility Mount I/O relays and I/O SSRs freely. Electric-shock preventive (finger-touch protection) terminal block incorporated conforming to VDE
More informationModel Number Structure
Solid State Relays CSM DS_E_3_1 Compact, Low-cost, SSR Switching 5 to 20 A Wide load voltage range: 75 to 264 VAC. Both 100-V and 200-V loads can be handled with the same model. Dedicated, compact aluminum
More informationRelays & Sockets RR Series Power Relays. Part Number Selection
RR Series Power Relays Key features: SPDT through PDT, A contacts Midget power type relays Available in pin and blade terminal styles. Options include an indicator, check button for test operations and
More informationSlim Relay G2RV. Model Number Structure. Ordering Information. Model Number Legend. List of Models. Relay and Socket Combinations
Slim Relay G2RV The World's First Industrial Slim Relay Large plug-in terminals for reliable connection. LED indicator and mechanical flag to check operation. Transparent housing enables checking relay
More informationP7TF-IS16/OS16/OS08. I/O classification I/O points Internal I/O common Rated voltage Model 12 VDC P7TF-IS16 DC12 24 VDC P7TF-IS16 DC24 For inputs
I/O Terminal Socket PTF-IS/OS/OS CSM_PTF-IS_OS_OS_DS_E I/O Terminal Sockets to Flexibly Build Systems Mount either GT I/O Relays or GTA SSRs. Compact size for both Input and Output I/O Terminal Sockets:
More informationD2D. Door Interlock Switch. Ordering Information. Power Switch with Minimum Contact Gap of 3 mm. Model Number Legend.
Door Interlock Switch Power Switch with Minimum Contact Gap of 3 mm Offers the minimum contact gap of 3 mm required for power switches as standard equipment. Highly reliable design conforms to European
More informationRUC-M industrial relays for DC loads
Contact data Number and type of contacts Contact material Rated / max. switching voltage Min. switching voltage Rated load Min. switching current Max. inrush current Rated current Min. breaking capacity
More informationFerrous metal (The sensing distance decreases with non-ferrous metal.) Power supply voltage (operating voltage range)
Description The sensors provide excellent results even with difficult-to-detect objects, e.g. small or thin parts, wires or bright metals. A variety of types cover a wide range of individual requirements
More informationOrdering Information. I/O Relay G7T. Model Number Legend Slim-styled I/O Relay Saves Space in Panel
I/O Relay CSM DS_E_4_4 Slim-styled I/O Relay Saves Space in Panel SPST-NO, SPST-NC, and SPDT contact forms available for output (SPST-NO only for input). Ultra-slim housing measuring 29 (W) x 0 (D) x 2
More informationConnector Built-in U-shaped Micro Photoelectric Sensor. Approximately 60 % of previous model Detachable
44 Connector Built-in Micro Photoelectric SERIES Related Information General terms and conditions... F-1 Glossary of terms... P.1~ selection guide... P.441~ General precautions... P.140 Amplifier Built-in
More informationClassification Enclosure rating Input voltage Type of
Slim Relay G2RV The World's First Industrial Slim Relay Large plug-in terminals for reliable connection. LED indicator and mechanical flag to check operation. Special input type with gold plated contacts.
More informationInductive Proximity Sensor
Inductive Proximity Sensor Miniature, Slim-styled Proximity Sensor Space-saving Sensor ideal for timing cam and dog detection. Four mounting holes provided: two each mounting from side or rear of the housing.
More informationOrdering Information. I/O Relay G7T. Model Number Legend Slim-styled I/O Relay Saves Space in Panel
I/O Relay CSM DS_E_2_ Slim-styled I/O Relay Saves Space in Panel SPST-NO, SPST-NC, and SPDT contact forms available for output (SPST-NO only for input). Ultra-slim housing measuring 29 (W) x 0 (D) x 2
More informationSYSMAC Remote Transistor Module
9 SYSMAC Remote Transistor Module Ultra-compact Remote I/O Modules to Match Most Applications 1 4-point, 8-point and 16-point models 1 4-point models measure 82 W x 32 D x 64.5 H mm; 8- and 16-point models
More informationWiring Systems I/O Blocks, I/O Terminals, and I/O Block Bases
Wiring Systems I/O Blocks, I/O Terminals, and I/O Block Bases Wiring Systems Programmable Controllers G7@ Relay I/O Blocks and Cables 383 G70A I/O Terminal Bases 386 G70D Relay Output Terminal Blocks 387
More informationG3NE. Ordering Information. Solid State Relay. Compact, Low-cost, SSR Switching 5to20A J ACCESSORIES (ORDER SEPARATELY) Solid State Relay G3NE
Solid State Relay G3NE Compact, Low-cost, SSR Switching 5to20A D Wide load voltage range: 75 to 264 VAC. D Dedicated, compact aluminum PCB and power elements used. D Built-in varistor effectively absorbs
More informationRT-1 PC RELAY TERMINAL RT-1 PC TERMINAL
RT- Wide variation relay RT- PC RELAY TERMINAL RT- PC TERMINAL RT- PC Relay (PQ relays mounted) RT- PC points points points points FEATURES. Easy connecting and simplified wiring Connection to the various
More informationRelays & Sockets. RQ Series. RQ Series PCB Relays Part Number Selection
Q Series Q Series PB elays Switches & Pilot Lights Display Lights IDE Q relays are low-profile, PB relays that provide quality within a compact package. Size equals value. Q relays are small, yet maintain
More informationOne step ahead in performance and mounting ease
95 Micro Photoelectric Amplifier Built-in PM-5 SERIES PM-45 SERIES PM-5 SERIES General terms and conditions... F- guide... P.9~ Related Information Glossary of terms / General precautions...p.1549~ / P.155~
More information78 Series Electromechanical Relay Selection Guide
78 Series Electromechanical Relay Selection Guide Specification 781 Series 782 Series 783 Series 784 Series Coil Voltages Configuration SPDT DPDT 3PDT 4PDT Contact Rating 15A 15A 15A 15A Base Socket 5
More informationDPST-NO None 2 channels Auto-reset Inverse (+/-) 24 VAC/VDC 4 G9SB-2002-A 1 channel or 2
Safety Relay Unit Ultra Slim Safety Relay Unit 17.5 mm wide models available with 2 or 3 poles. 22.5 mm wide 3 pole models also available EN Standards (TÜV approval) DIN-track mounting possible Ordering
More informationD2D. Door Interlock Switch. Ordering Information. Power Switch with Minimum Contact Gap of 3 mm. Model Number Legend.
Door Interlock Switch Power Switch with Minimum Contact Gap of 3 mm Offers the minimum contact gap of 3 mm required for power switches as standard equipment. Highly reliable design conforms to European
More informationUltra-small U-shaped Micro Photoelectric Sensor. Extremely small size enables space saving!! 12 mm in
1 Ultra-small Micro Photoelectric PM- SERIES Related Information General terms and conditions... F-17 Glossary of terms / General precautions... P.19~ / P.10 Amplifier Built-in selection guide... P.1~
More informationModbus Digital Remote I/O. ARM Series. Modbus Sensor Connector Type Digital Remote I/O. Features. User Manual For Communication. Ordering Information
RM Series Modbus Digital Remote I/O Modbus Connector Type Digital Remote I/O Features Modbus RTU standard protocol Connects with sensor connector, e-con: saves wiring work (sensor connector, CNE Series,
More informationPM-24 SERIES. Ultra-small U-shaped Micro Photoelectric Sensor. Extremely small size enables space saving!! ( ) Equipped with two independent outputs
19 Ultra-small Micro Photoelectric Sensor PM- SERIES Related Information General terms and conditions...p.1 Glossary of terms / General precautions...p.98~ / P.98~ Amplifier Built-in Sensor selection guide...p.11~
More informationPhotoelectric Sensors E3F2
Photoelectric Sensors E3F2 Threaded Cylindrical Photoelectric Sensors with Built-in Amplifier for Use as an Optical Proximity Switch M18 DIN-sized cylindrical housing Housing materials: plastic, nickel
More informationSafety Relay Unit (I/O Unit Type)
Safety Relay Unit (I/O Unit Type) CQM1-SF200/ CS1W-SF200 Same Dimensions as I/O Unit Less Installation Space and Wiring Required Safety Relay Unit that can be used as an I/O Unit for OMRON s CQM1H and
More informationPRODUCT SPECIFICATION. PC Board Relays. Series.
PRODUCT SPECIFICATION PC Board Relays 26 Series www.wernerelektrik.com Technical Data... Specifications...2 Model Number Structure - Relays...3 Model Number Selection...4 Dimensions... 5-6 Accessories...7
More informationH3CA-8H-AC/100/110/120
Solid-State Timer 1/16 DIN, Digital-Set Timer with 0.1 Second to 9,990 Hours Range 8 field-selectable operation modes Universal AC/DC supply voltage timers available Operations include ON-delay, Repeat
More information2. Actuator B: Ball type P: Pin type F: Flat type
Contact Displacement Sensor Built-in Amplifier Ensures Ease of Use and Saves Wiring Effort. Sensor Operates with a Low Force in a Wide Range of Applications. H Works with a low operating force (30 gf)
More informationModel Number Structure
ASH & ALAIN INDIA PVT LTD S-100, F.I.E.E., Okhla Industrial Area, Phase-ii, New Delhi-110020(India) Tel : 011-43797575 Fax : 011-43797574 E-mail : sales@ashalain.com Solid State Relays G3 @-VD CSM_G3F_G3FD_DS_E_2_1
More informationRUC industrial relays of small dimensions
RUC industrial relays of small dimensions 135 with adaptor (V) Contact data Number and type of contacts Contact material Rated / max. switching voltage Min. switching voltage Rated load Min. switching
More informationHIGHLY SENSITIVE 1500 V FCC SURGE BREAKDOWN VOLTAGE MINIATURE RELAY
HIGHLY SENSITIVE 1500 V FCC SURGE BREAKDOWN VOLTAGE MINIATURE RELAY DS RELAYS RoHS Directive compatibility information http://www.mew.co.jp/ac/e/environment/ FEATURES 1. Breakthrough height of 9.8 mm.386
More informationSA1E: Photoelectric Switches. Polarized Retroreflective Type. Through-beam Type
SAE: Photoelectric Simple, compact design for world-wide usage. Key features of the SAE photoelectric sensor include: Four sensing methods Cable types and M8 connector types available NPN output, PNP output,
More informationRUC industrial relays of small dimensions
Contact data Number and type of contacts Contact material Rated / max. switching voltage Min. switching voltage Rated load Min. switching current Max. inrush current Rated current Max. breaking capacity
More informationIce Cube Relays. R2/R4 Plug-in Power Relays... G58 Technical Information... G63. R15 Plug-in Power Relays... G68 Technical Information...
Ice Cube Relays R2/R4 Plug-in Power Relays... 58 Technical Information... 63 R15 Plug-in Power Relays... 68 Technical Information... 72 RUC Plug-in Power Relays... 76 Technical Information... 79 RY2 Plug-in
More informationD2VW. Sealed Miniature Basic Switch. Ordering Information Model Number Legend D2VW- -
Sealed Miniature Basic Switch Sealed Miniature Basic Switch Conforms to IP67 (Molded Lead Wire Type Only) Use of epoxy resin assures stable sealing, making this switch ideal for places subject to water
More informationPRCMT18-5DO PRCMT18-5DC PRCMT18-5DO-I PRCMT18-5DC-I
PRCM Series Cylindrical Connector Type Proximity Sensor Features Improved the noise immunity with dedicated IC Built-in reverse polarity protection circuit (DC -wire type) Built-in surge protection circuit
More information7. Approved Standards US: UL, CSA UL: FILE No.E CSA: FILE No.LR31928) 8. Special Function None : Standard U : For ultrasonically cleanable
Subminiature, Sensitive SPDT Signal Switching Relay High sensitivity: 98-mW (Rated power consumption: mw) pickup coil power. Impulse withstand of 1,V ( 1 μs) meets FCC requirements. Stick packing employed
More informationSafety Control. FS1A Multi-function Safety Relay. Optional Parts. Connecting Tool. Marked Cable Tie. DIN Rail BNDN1000 Aluminum, 1m 35mm wide
Multi-function Relay Key features: No programming required. Configuration complete by turning on a logic switch A safety circuit can be configured easily just by selecting a logic from eight preprogrammed
More informationE3S-A. Built-in Amplifier Photoelectric Sensor (Medium Size) Ordering Information. Built-in Amplifier Photoelectric Sensors. Horizontal. 7 m.
Built-in Amplifier (Medium Size) ES-A Be sure to read Safety Precautions on page 0. Ordering Information Built-in Amplifier s Red light Infrared light Sensing method Appearance Connection method Sensing
More information4 C/O. Contact material AgNi AgNi gold-plated Nominal contact current Inrush current
Quattro-Relais Quattro Relay 4 Quattro Relay 4A4 Standard type / With LED and protection diode on request Quattro-Relais Order Code Order Code Quattro Relay 4 A 4 4 V DC N Type of relay Quattro Relay 4
More information4. Sensing Distance. 2: 2 mm. 4: 4 mm 8: 8 mm 15: 15 mm 16: 16 mm 20: 20 mm
Inductive Sensor Double Sensing Distance Model Number Legend SALIENT FEATURES IP - 7, Brass Housing Short - Circuit protection Reverse Polarity Protection Shielded and Non - Shielded Prewired and Connector
More informationGT3F Series True OFF Delay Timers
TF Series TF Series True OFF Delay Key features of the TF series include: Mountable in sockets or flush panel True power OFF-delay up to 10 minutes No external control switch necessary Available with reset
More informationSafety Control. FS1A Multi-function Safety Relay. Optional Parts. Marked Cable Tie. DIN Rail BNDN1000 Aluminum, 1m 35mm wide
Control Multi-function Relay Key features: No programming required. Configuration complete by turning on a logic switch A safety circuit can be configured easily just by selecting a logic from eight preprogrammed
More informationRM84 miniature relays
RM84 miniature relays RM84 Contact data Number and type of contacts Contact material Rated / max. switching voltage Min. switching voltage Rated load (capacity) AC AC1 AC15 DC1 DC13 Motor load acc. to
More information1.5 Solid State Relays
Relays.. Solid State Relays Application s Pins Contacts AC ratings DC ratings Socket CSS Series AC Solid state, Instantaneous switching CSS-I A / 0 V S0 AC Solid state synch. to zero crossing CSS-Z A /
More informationMain contacts Auxiliary contact Number of input channels Rated voltage Model Category 24 VAC/VDC 3PST-NO SPST-NC 1 channel or 2 channels possible
Safety Relay Unit Four kinds of -mm wide Units are available: A -safety contact model, a -safety contact model, and models with safety contacts and OFF-delay safety contacts. Also available are 7.-mm wide
More informationSolid-State Counter/Timer
Solid-State Counter/Timer 1/16 DIN, Easy-to-Operate Combination Counter and Timer Operation selectable as preset counter or timer 6-digit LCD display Present Value: 8 mm (0.32 in) Set Value: 4 mm (0.16
More informationCompact Inductive Proximity Sensor
SERIES Compact Inductive Proximity Sensor Amplifier Built-in High functionality together with robust housing and flexible cable Miniature is an amplifier built-in inductive proximity sensor having a diameter
More informationLight ON 5m. * Light ON. 2.5m (3m) Light ON. (5m)
All voltage photoelectric sensors Built-in amplifier accepts wide supply voltage range. Slim, space-saving construction measures only x x 7.4 mm. s with long life expectancy and high switching capacity
More informationRUC industrial relays of small dimensions
with adaptor (V) with adaptor (H) Power relays of general application AC and DC coils Mounting: in sockets; 35 mm rail mount acc. to PN-EN 60715; on panel; PCB Versions: faston 187 (4,8 x 0,5 mm); faston
More informationonlinecomponents.com
Standard-type Connector- Conversion Units XWB CSM_XWB_DS_E Simplifies Connector and terminal block replacement, and requires less in-panel wiring. Mount to DIN Track or via screws. MIL Flat Cable Connectors
More informationG9SX-LM. Low-speed Monitoring Unit. Low-speed Monitoring Function Ensures Safety for Maintenance Work. Model Number Structure.
Low-speed Monitoring Unit G9SX-LM Low-speed Monitoring Function Ensures Safety for Maintenance Work Motor rotation speed detected by Proximity Sensor. Monitors and confirms that speed does not exceed the
More informationOrdering Information. Door Interlock Switch D2D. Power Switch with Minimum Contact Gap up to 3 mm. D2D - 0. Model Number Legend
Door Interlock Switch D2D Power Switch with Minimum Contact Gap up to 3 mm. Minimum contact gap of 3 mm (standard models), needed in general power switches, is provided. Mechanism with double return spring
More informationPage Housing Plastic Metal Mounting DIN Rail or surface mount Panel or bracket mount Wattage Range 10W to 240W 7.5W to 240W 10W to 300W
Selection Guide Selection Guide PS5R Slim Line PS5R PS3L Operator Interfaces Communication & Networking PLCs NEW Models Appearance Automation Software Page 107 113 118 Housing Plastic Metal Mounting DIN
More informationmasterelectronics.com onlinecomponents.com
Basic Switch MINIATURE Watertight Miniature Basic Switch High-quality watertight, high-precision miniature basic switch meets IP67 requirements (IEC 529) Monoblock construction assures high sealing capability
More informationSlim Industrial Relay Type RSLM Electromechanical
Type RSLM Electromechanical RSLM Slim size (width 5mm) High breakdown voltage 4kV (between coil and contacts) Surge voltage up to 6kV (between coil and contacts) Conforms to VDE 0700, 0631 reinforced insulation
More informationMICREX-SX Series Renewal Tool Announcement of Release of MICREX-F Size I/O Module
Dear Customers, January 2016 Fuji Electric Co., Ltd. MICREX-SX Series Renewal Tool Announcement of Release of MICREX-F Size I/O Module Thank you for using the Fuji programmable controller. We hereby announce
More informationInductive Proximity Sensor
Inductive Proximity Sensor Subminiature Sensor with Cable Amplifier Offers Greater Mounting Flexibility Programmable Controller-compatible Subminiature, shielded sensing head (3 or 8 dia.) allows the Sensor
More informationMonitor. Safety relay,etc. Contactor, etc. Uses external device monitoring function Note: Construct a separate reset input circuit.
Selectable safety circuits The light curtain unit has a built-in monitoring function for external devices (such as fused relay monitoring). This supports the construction of light curtain peripheral safety
More informationThread length (overall length) material
Cylindrical Proximity Sensor for Mobile Usage Designed and tested to keep your machines moving IP69k tested and certified for highest water resistance e1 type approval (according to automotive directive
More informationOptimum sensing capability for LCD manufacturing
SENSORS FOR Glass Substrate Detection Sensor Amplifier-separated FX-301-F FT-F9 FD-F7 EX-F70/F60 HD-T1 M FD-L3 Reliable detection of glass substrates Its unique optical system enables detection of transparent
More informationOperation mode. Output configuration. Relay DC SSR. Light-ON Dark-ON (switch selectable) Relay DC SSR. Relay DC SSR
Built-in Power Supply Photoelectric Sensor CSM DS_E_12_3 Model Contribute to Overall Cost Reduction erminal Block Models Easy to wire and adjust. For the most recent information on models that have been
More informationTimers. GT5Y Series ON Delay Timers. ±3% maximum (over 10 to 50 C, reference temperature 20 C) Setting Error. ±10% maximum
GT5Y GT5Y Series ON Delay Key features: 4PDT, 3A or DPDT, 5A contacts 4 time ranges Repeat error ±0.2% maximum Control settings by hand or screwdriver Power ON and timing out LED indicators Uses the same
More informationSafety Monitoring Relays
Safety Monitoring Relays G9SA G9SA Safety Relay Unit Four kinds of 45-mm wide units are available: A 3-pole model, a 5-pole model, and models with 3 poles and 2 OFF-delay poles, as well as a two-hand controller.
More informationBasic Switch. Pin plunger Short hinge Hinge lever Long hinge lever Simulated hinge Short hinge Hinge roller lever lever roller lever lever
Basic Switch MINIATURE Watertight Miniature Basic Switch High-quality watertight, high-precision miniature basic switch meets IP67 requirements IEC 529 (lead wire type) Monoblock construction assures high
More informationHIGHLY SENSITIVE 1500 V FCC SURGE BREAKDOWN VOLTAGE MINIATURE RELAY
HIGHLY SENSITIVE 15 V FCC SURGE BREAKDOWN VOLTAGE MINIATURE RELAY DS RELAYS FEATURES 1. Breakthrough height of 9.8 mm.386 inch beats the 1 mm.394 inch limit 1c, 2c, and 4c all have the same height (9.8
More informationSPST-NO SPDT DPST-NO DPDT
Next-generation PCB Relay Available in Various Models ROHS compliant. High sensitivity: (250mW) and high capacity (16A) models available Low profile: 15.7 mm max. in height. Conforms to EN 61810-1, UL508
More informationMini Contactors & Overloads
108 Mini s & Overloads GMC-12M Surface or DIN rail mountable UL508 compliant 1/ to 7-1/ 50/60Hz AC and DC versions available Direct-mounting overloads RoHS compliant Auxiliary contacts standard (1 N.0.)
More informationTransistor I/O Link Modules
9 Transistor I/O Link Modules Reduce Wiring Back to PLC Rack for 32 I/O Points 1 Transmit 16 input signals over just 2 wires (3 wires if only one terminal has a power supply) 1 Normal I/O delay (19.2 ms
More information16 g SS-01GL-FD SS-01GL-F SS-01GL-FT 50 g SS-01GLD SS-01GLD1 SS-01GLD2 SS-01GL SS-01GLT Simulated roller lever
Snap Action Switch SS Subminiature Snap Action Switch Economical, subminiature snap action switch offers long service life (30 million operations minimum) All models are free from overtravel restrictions,
More informationTIMERS FOR ALL APPLICATIONS
Timers Overview TIMERS FOR ALL APPLICATIONS AutomationDirect now offers solid-state timers brought to you by two leaders in the industry, FUJI and Koyo. FUJI Electric has been in business since 1923 and
More informationModel Number Structure
Solid State Relays CSM DS_E_2_1 I/O SSRs That Mount to OMRON s G7TC I/O Block Input and output modules are available in wide variety. Snaps easily into P7TF I/O Terminals and can be used together with
More informationE3S-A. Built-in Amplifier Photoelectric Sensor (Medium Size) Ordering Information. Built-in Amplifier Photoelectric Sensors. Horizontal. 7 m.
Built-in Amplifier (Medium Size) ES-A CSM_ES-A_DS_E Be sure to read Safety Precautions on page 0. Ordering Information Built-in Amplifier s Red light Infrared light Sensing method Appearance Connection
More informationZelio Relay - plug-in relays
Presentation Presentation offer the advantages of compact size and modular design: their slim width ( mm) saves space when mounting on a rail at the back of an enclosure. RSL relays are available in two
More informationContact form. Operating Force. Plunger SPDT 204g Dust- Proof (in closed position) Plunger SPST-NC 204g Dust- Proof (in closed position)
D3D Miniature Door Switch Appliance industry standard plunger and lever actuator styles High contact reliability ensured using gold alloy crossbar contacts Drip/spill sealing in free position (plunger
More informationSolid State Relays with Failure Detection Function
Solid State Relays with Failure Detection Function CSM DS_E_2_1 Refer to Safety Precautions for All Solid State Relays. Detects failures in SSR used for heater temperature control and simultaneously outputs
More informationTerminal block 2 A 5 X 3. Specification
D Series Features Automatic communication speed recognition : Enables to recognize communication speed automatically when connecting with master Network Voltage monitoring : If PV is lower than SV, enables
More informationDigital I/O Units Compatible with MULTIPLE I/O TERMINAL
Digital I/O Units T-@D(-)/@DMX(-)/@DML(-)/@DML(-)/@DDS(-) Digital I/O Units Compatible with MULTIPLE I/O TERMAL Terminal block, connector, and high-density connector models are available. The circuit block
More information3 Pole Contactors with AC operating coils
1 3 Pole Contactors with AC operating coils Characteristics General Characteristics Switching Current 9A ~ Rated insulation voltage (Ui) (Conforming to IEC 158-1) V 750 IEC 60947-4 V 1000 Conforming to
More informationPRD/PRDW Series. Long Distance Type
Long Distance Type Long distance proximity Features Long sensing distance (. to times longer sensing distance guaranteed compared to existing models) Improved the noise resistance with dedicated IC Built-in
More information29 $ Manual Motor Starters FREESHIPPING. MOTOR CONTROLS 25. Features: MMS-32H Frame. MMS-63H Frame.
www.factorymation.com/motorcontrols MOTOR CONTROLS 25 Manual Motor Starters High interrupt capacity Din rail and surface mounting Lockable handle (OFF position) IP20 finger safe terminals Class 10 thermal
More informationContact form. Operating Force. SPDT 25g Unsealed Solder / 187 Quick Connect. SPDT 50g Unsealed Solder / 187 Quick Connect
VX Miniature Snap Action Switch Compact snap action switch with low force operation Internal mechanism assures outstanding contact reliability Models available for micro load up through 5 Amps ROHS Compliant
More informationSlim Relay G2RV. Model Number Structure. Model Number Legend. The World's First Industrial Slim Relay NTLP: WAITING FOR @
Slim Relay 2R The World's First Industrial Slim Relay arge plug-in terminals for easy connection. ED indicator and mechanical flag to check operation. Transparent housing enables checking relay condition.
More informationGX SERIES. Cylindrical Compact Inductive Proximity Sensor Amplifier Built-in. Robust enclosure and flexible cable types are also available
8 Cylindrical Compact Inductive Proximity SERIES Related Information General terms and conditions... F-7 Glossary of terms... P.86~ selection guide... P.757~ General precautions... P.05 PHOTO PHOTO Conforming
More informationCylindrical Compact Inductive Proximity Sensor Amplifier Built-in. panasonic.net/id/pidsx/global
8 PHOTO PHOTO MEASURE Cylindrical Compact Inductive Proximity SERIES Related Information General terms and conditions... F- Glossary of terms... P.576~ panasonic.net/id/pidsx/global guide... P.78~ General
More informationSwitching Power Supply S8E1. Ordering Information. Compact and Economical Switching Power Supply
Switching Power Supply Compact and Economical Switching Power Supply Models range from 10 to 50 W Open-frame and covered types Wide range of output voltage: 5-, 12-, 15- and 24-V models UL, CSA approved
More informationSRT2-ROC08, SRT2-ROC16
Ultra-miniature 8-point and 16-point Relaymounted Terminals Ultra-compact (8-point models: 101 x 51 x 51 mm (W x H x D); 16-point models: 156 x 51 x 51 mm (W x H x D)) MOS FET Relay and Relay models. DIN
More informationTemperature Controller E5C4
Temperature Controller 1/16 DIN Sized, Digital-Set Controller Features Easy-to-Read LED Display Proportional-derivative (PD) control or ON/OFF control models Front panel offset adjustment on PD controllers
More information