DCS-E 1kW Series, DLM-E 3kW & 4kW Power Supplies

Size: px
Start display at page:

Download "DCS-E 1kW Series, DLM-E 3kW & 4kW Power Supplies"

Transcription

1 DCS-E 1kW Series, DLM-E 3kW & 4kW Power Supplies M51A Option: Isolated Analog Programming Manual Power Supplies Elgar Electronics Corporation 9250 Brown Deer Road San Diego, CA ELGAR ( ) Tel: (858) Fax: (858) Elgar Electronics Corporation This document contains information proprietary to Elgar Electronics Corporation. The information contained herein is not to be duplicated or transferred in any manner without prior written permission from Elgar Electronics Corporation. June 8, 2004 Document No. M Rev B

2 SAFETY NOTICE Before applying power to the system, verify that the instrument is configured properly for the user s particular application. WARNING! Hazardous voltages may be present when covers are removed. Qualified personnel must use extreme caution when servicing this equipment. Circuit boards, test points, and output voltages also may be floating with respect to chassis ground. Installation and servicing must be performed by qualified personnel who are aware of dealing properly with attendant hazards. This includes such simple tasks as fuse verification. Ensure that the AC power line ground is connected properly to the chassis. Similarly, other power ground lines including those to application and maintenance equipment must be grounded properly for both personnel and equipment safety. Always ensure that facility AC input power is de-energized prior to connecting or disconnecting any cable. In normal operation, the operator does not have access to hazardous voltages within the chassis. However, depending on the user s application configuration, HIGH VOLTAGES HAZARDOUS TO HUMAN SAFETY may be normally generated on the output terminals. The customer/user must ensure that the output power lines are labeled properly as to the safety hazards and that any inadvertent contact with hazardous voltages is eliminated. Guard against risks of electrical shock during open cover checks by not touching any portion of the electrical circuits. Even when power is off, capacitors may retain an electrical charge. Use safety glasses during open cover checks to avoid personal injury by any sudden component failure. Some circuits are live even with the front panel switch turned off. Service, fuse verification, and connection of wiring to the chassis must be accomplished at least five minutes after power has been removed via external means; all circuits and/or terminals to be touched must be safety grounded to the chassis. These operating instructions form an integral part of the equipment and must be available to the operating personnel at all times. All the safety instructions and advice notes are to be followed. Neither Elgar Electronics Corporation, San Diego, California, USA, nor any of the subsidiary sales organizations can accept any responsibility for incidental or consequential injury of personnel, or loss or damage of equipment or material that results from improper use of the equipment and accessories. i

3 SAFETY SYMBOLS ii

4 ELGAR FIVE YEAR WARRANTY Elgar Electronics Corporation (hereinafter referred to as Elgar) warrants its products to be free from defects in material and workmanship. This warranty is effective for one year from the date of shipment of the product to the original purchaser. Liability of Elgar under this warranty shall exist provided that: the Buyer exposes the product to normal use and service and provides normal maintenance on the product; Elgar is promptly notified of defects by the Buyer and that notification occurs within the warranty period; the Buyer receives a Return Material Authorization (RMA) number from Elgar s Repair Department prior to the return of the product to Elgar for repair, phone ELGAR ( ), ext. 2295; the Buyer returns the defective product in the original, or equivalent, shipping container; if, upon examination of such product by Elgar it is disclosed that, in fact, a defect in materials and/or workmanship does exist, that the defect in the product was not caused by improper conditions, misuse, or negligence; and, that Elgar QA seal and nameplates have not been altered or removed and the equipment has not been repaired or modified by anyone other than Elgar authorized personnel. This warranty is exclusive and in lieu of all other warranties, expressed or implied, including, but not limited to, implied warranties of merchantability and fitness of the product to a particular purpose. Elgar, its agents, or representatives shall in no circumstance be liable for any direct, indirect, special, penal, or consequential loss or damage of any nature resulting from the malfunction of the product. Remedies under this warranty are expressly limited to repair or replacement of the product. CONDITIONS OF WARRANTY To return a defective product, contact an Elgar representative or the Elgar factory for an RMA number. Unauthorized returns will not be accepted and will be returned at the shipper s expense. For Elgar products found to be defective within thirty days of receipt by the original purchaser, Elgar will absorb all ground freight charges for the repair. Products found defective within the warranty period, but beyond the initial thirty-day period, should be returned prepaid to Elgar for repair. Elgar will repair the unit and return it by ground freight pre-paid. Normal warranty service is performed at Elgar during the weekday hours of 7:30 am to 4:30 pm Pacific time. Warranty repair work requested to be accomplished outside of normal working hours will be subject to Elgar non-warranty service rates. Warranty field service is available on an emergency basis. Travel expenses (travel time, per diem expense, and related air fare) are the responsibility of the Buyer. A Buyer purchase order is required by Elgar prior to scheduling. A returned product found, upon inspection by Elgar, to be in specification is subject to an inspection fee and applicable freight charges. Equipment purchased in the United States carries only a United States warranty for which repair must be accomplished at the Elgar factory. Committed to Quality...Striving for Excellence iii

5 CONTENTS SECTION 1 M51A OPTION OVERVIEW Introduction General Description Specifications Electrical Specifications Supplemental Characteristics SECTION 2 ISOLATED ANALOG PROGRAMMER OPERATION SW1 Switch SW1 Switch Setup ISOLATED ANALOG PROGRAMMER Connector (J4) ISOLATED ANALOG PROGRAMMER Functions Remote Programming Configuration Voltage Source Programming of Output Voltage Voltage Source Programming of Output Current Voltage Source Programming of OVP Resistance Programming of Output Voltage Resistance Programming of Output Current Resistance Programming of OVP mA Current Source Programming of Output Voltage mA Current Source Programming of Output Current Programming the Shutdown Function TTL Shutdown Shutdown Application Contact Closure Local/Remote Application Remote Monitoring Remote Digital Status Signals M51A Option v

6 Contents DLM-E Series and DCS-E Series LIST OF TABLES Table 2 1. SW1 SETUP Switch Table 2 2. ISOLATED ANALOG PROGRAMMER Connector Pinout Table 2 3. Remote Monitoring Table 2 4. Remote Digital Status Signals LIST OF FIGURES Figure 2 1. Rear Panel View, DLM-E Series 3kW and 4kW Power Supply Figure 2 2. Rear Panel View, DCS-E Series 1kW Power Supply Figure 2 3. Using Shutdown with a DC Input (Positive Logic) Figure 2 4. Using Shutdown with Contact Closure of a Normally OPEN Relay (SW1-6 ON) Figure 2 5. Using Shutdown with Contact Closure of a Normally OPEN Relay (SW1-6 OFF) Figure 2 6. Using Shutdown with Contact Closure of a Normally CLOSED Relay (SW1-6 ON) Figure 2 7 Using Local/Remote Operation with Contact Closure vi M51A Option

7 SECTION 1 M51A OPTION OVERVIEW 1.1 Introduction This manual is to be used in conjunction with the DCS-E 1kW Series & DCS-E 1.2kW Series DC Power Supplies Operation Manual, Sorensen Document No. M and the DLM-E 3Kw & 4Kw Series Power Supplies Operation Manual, Sorensen Document No. M The Sorensen M51A Option provides a remote isolated analog programming interface, which has safety isolation from the output terminals. This allows the remote analog interface to be connected to user accessible, Safety Extra Low Voltage, (SELV) control circuits, even though the output terminals are floated at a high potential with respect to the chassis. 1.2 General Description The M51A Option provides isolation for all programming, monitoring, and digital I/O signals that are available through the standard rear panel analog interface connector. This isolation barrier eliminates the connection that exists in the standard models between the non-isolated remote interface circuits and the power supplies output return (negative) terminal. All control and monitoring signals on the M51A option are optically coupled from the power supply output, and can are user accessible irrespective of the float potentials that could exist at the output terminals. The M51A Option provides a full complement of programming, monitoring, and control functions. Remote programming is available for output voltage, current, and overvoltage protection (OVP). Analog output monitor signals are available for the output voltage and current. Digital I/O signals provide indication of the operational state, and a means of enabling the remote interface and the output. The type and range of the control and monitor signals are user-selectable with a rear panel setup switch and connector jumpers. The output voltage, current, and OVP can be programmed with a 0-5VDC, 0-10VDC, or 0-5kΩ resistance; in addition, the output voltage and current can be programmed with 4-20mA signals. The output voltage and current monitors can produce 0-5VDC, 0-10VDC, or 4-20mA signals. Isolated 1mA current sources are provided to facilitate the utilization of 0-5kΩ programming resistances. Except for the isolated remote analog interface, the installation and operation of the power supplies remains as presented in the Operation Manual. The following sections provide a detailed description of the new features and the differences in operation. M51A Option 1-1

8 M51A Option Overview DLM-E Series and DCS-E Series 1.3 Specifications Electrical Specifications Remote Voltage Programming Accuracy, 0-5/10V Inputs: Output Voltage: 0.5% of Vmax Output Current: 0.75% of Imax OVP: 1.0% of 1.1 X Vmax Remote 4-20 ma Programming Accuracy: Output Voltage: 1.0% of Vmax Output Current: 1.0% of Imax Burden voltage of 6.25 VDC (312.5 ohms nominal) Supplemental Characteristics Remote Resistance Programming Accuracy, 0-5kΩ Input: Output Voltage: 1.0% of Vmax Output Current: 1.5% of Imax OVP: 1.5% of 1.1 X Vmax Remote Monitor Accuracy: Output Voltage, 0-5/10V ranges: 0.5% of Vmax Output Voltage, 4-20mA: 1.0% of Vmax Output Current, 0-5/10V ranges: 0.75% of Imax Output Current, 4-20mA: 1.0% of Imax Electrical Isolation: 500 VDC from all isolated inputs to supply output 1-2 M51A Option

9 SECTION 2 ISOLATED ANALOG PROGRAMMER OPERATION 2.1 SW1 Switch The SW1 SETUP switch is accessible from the rear panel of the unit. It provides user selection of the programming/monitoring ranges and shutdown logic signal level. Setting a switch to the 1 or 0 position changes a range. The factory default settings are shown below. Refer to Figure 2 1 for a rear panel view of the DLM-E 3kW and 4kW models. Refer to Figure 2 2 for a rear panel view of the DCS-E 1kW models. Switch Position Function OFF (0) Position ON (1) Position Voltage Programming Range Select Current Programming Range Select OVP Programming Range Select Output Voltage Monitor Range Select Output Current Monitor Range Select Remote ON-OFF Level Select 0-10 VDC * 0-5 VDC, 4-20mA 0-10 VDC * 0-5 VDC, 4-20mA 0-10 VDC * 0-5 VDC * 0-5 VDC 0-10 VDC * 0-5 VDC 0-10 VDC Active Low Signal * Active High Signal * Indicates default settings Table 2 1. SW1 SETUP Switch M51A Option 2-1

10 Isolated Analog Programmer Operation DLM-E Series and DCS-E Series SW1 Switch Setup The following sections describe the functions of the various switch positions: Voltage Programming Range Select (V PROG): SW1-1, ON (1) position, selects 0-5VDC programming range for the output voltage. Must also be set to ON (1) position when the Isolated Analog Programmer is wired for 4-20mA input programming. OFF (0) position, selects 0-10VDC programming for the output voltage. Current Programming Range Select (I PROG): SW1-2, ON (1) position selects 0-5VDC programming range for the output current. Must also be set to ON (1) position when the Isolated Analog Programmer is wired for 4-20mA input programming. OFF (0) position, selects 0-10VDC programming for the output voltage. OVP Programming Range Select (OVP PROG): SW1-3, ON (1) position selects 0-5VDC programming of OVP threshold. OFF (0) position, selects 0-10VDC programming for OVP threshold. Output Voltage Monitor Range Select (V MON): SW1-4, ON (1) position selects 0-10VDC range for readback of output voltage. OFF (0) position selects 0-5VDC readback of output voltage. 4-20mA readback for output voltage is independent of the position of this switch. Output Current Monitor Range Select (I MON): SW1-5, ON (1) position selects 0-10VDC range for readback of output current. OFF (0) position selects 0-5VDC readback of output current. 4-20mA readback for output current is independent of the position of this switch. Remote ON-OFF Level Select (S/D): SW1-6, ON (1) position selects ACTIVE-HIGH logic level for disabling the output with the S/D signal of the Isolated Analog Programmer connector. OFF (0) position selects the ACTIVE-LOW logic level for disabling the output with the S/D signal of the Isolated Analog connector. Figure 2 1. Rear Panel View, DLM-E Series 3kW and 4kW Power Supply Figure 2 2. Rear Panel View, DCS-E Series 1kW Power Supply 2-2 M51A Option

11 DLM-E Series and DCS-E Series Isolated Analog Programmer Operation 2.2 ISOLATED ANALOG PROGRAMMER Connector (J4) The ISOLATED ANALOG PROGRAMMER connector is a 25-position female Subminiature-D type. The table below defines each pins function. Pin 1 ANALOG-CONTROL input 2 Isolated Analog Common 3 OVP programming input 4 Voltage monitor output, 4-20mA 5 VOLTAGE-MODE status output 6 Isolated Analog Common 7 Current monitor output, 0-5/10V Function mA voltage programming offset signal (-2.5VDC) 9 Voltage programming input, 0-5/10V 10 Current programming input, 0-5/10V mA current programming offset signal (-2.5VDC) 12 Isolated Analog Common 13 Return for 4-20mA current programming signal 14 Shut-Down input 15 Auxiliary 16VDC output (+) 16 OVP resistance programming output, 1mA source 17 OVP status output 18 FAULT status output 19 Voltage monitor output, 0-5/10V 20 Input for 4-20mA current programming offset signal (-2.5VDC) 21 Voltage resistance programming output, 1mA source 22 Current resistance programming output, 1mA source 23 Input for 4-20mA current programming offset signal (-2.5VDC) 24 Current monitor output, 4-20mA 25 Return for 4-20mA voltage programming Table 2 2. ISOLATED ANALOG PROGRAMMER Connector Pinout CAUTION The signals of the ISOLATED ANALOG PROGRAMMER have an internal connection to chassis ground. Damage could result if the voltage from signal returns, Pin-2, 6, 12, 13, and 25 to chassis ground exceeds 60VDC. M51A Option 2-3

12 Isolated Analog Programmer Operation DLM-E Series and DCS-E Series ISOLATED ANALOG PROGRAMMER Functions The following sections describe the functions of the various signals of the ISOLATED ANALOG Programmer. Circuit is SELV, and all connections have electrical isolation from the output of the unit. Pin numbers correspond to the rear panel J4 connector pin out of Table 2 2. Digital Control Input Signals ANALOG-CONTROL (Remote/Local): Pin-1, enables remote analog programming with an active-low logic level. When a low level is applied, the supply will power-up with the analog interface in control of the output voltage. When high, the power supply will be in local control mode. Signal return is at J4-2. EXTERNAL SHUT DOWN (S/D): Pin-14, disables the output when applied and supply is working in the Remote Control mode. Logic level can be selected with switch SW1-6 to be active high or low. Signal return is at J4-2. Digital Control Status Output Signals VOLTAGE-MODE: Pin-5, nominal 5VDC logic level indicates operation in constant-voltage mode. Low logic level indicates operation in constant current mode. Signal return is at J4-2. OVP: Pin-17, nominal 5VDC logic level indicates that the output has been disabled because of overvoltage protection. Signal return is at J4-2. FAULT: Pin-18, nominal 5VDC logic level indicates that the output is disabled because of an over temperature or shutdown fault. Signal return is at J4-2. Analog Monitor Signals VOLTAGE MONITOR, 0-5/10V: Pin-19, provides an analog readback of the output voltage with a 0-5VDC or 0-10VDC signal (user selectable with switch SW1-4) indicating 0-100% of full scale output. Signal is referenced to J4-6. VOLTAGE MONITOR, 4-20mA: Pin-4, provides an analog readback of the output voltage with a 4-20mA signal indicating 0-100% of full scale output. Signal return for the 4-20mA current is J4-6. CURRENT MONITOR, 0-5/10V: Pin-7, provides an analog readback of the output current with a 0-5VDC or 0-10VDC signal (user selectable with switch SW1-5) indicating 0-100% of full scale output. Signal return is at J4-6. CURRENT MONITOR, 4-20mA: Pin-24, provides an analog readback of the output current with a 4-20mA signal indicating 0-100% of full scale output. Signal return for the 4-20mA current is J M51A Option

13 DLM-E Series and DCS-E Series Isolated Analog Programmer Operation Analog Programming Signals OVP PROGRAMMING INPUT: Pin-3, an input signal of 0-5 volts or 0-10 volts (user selectable with switch SW1-3) programs the OVP threshold from 5-110% of full scale output voltage. Signal return is at J4-12. Note: The OVP input is programmed to 110% by an internal connection between the 1mA source on Pin-16 to a separate circuit. This allows the user to program remotely without having to provide a separate programming source or jumper to the OVP input. VOLTAGE PROGRAMMING INPUT: Pin-9, an input signal of 0-5 volts, 0-10 volts or 4-20mA programs the output voltage from 0-100% of full scale. a) An input signal of 0-5 volts or 0-10 volts (user selectable with switch SW1-1) programs the output voltage from 0-100% of full scale. Signal return is at J4-12. b) An input signal of 4-20mA (with switch SW1-1 set to ON (1) position, programs the output voltage from 0-100% of full scale. Jumpers from J4-25 to J4-12 and J4-20 to J4-8 are also required. Signal return for the 4-20mA current is J4-25. CURRENT PROGRAMMING INPUT: Pin-10, an input signal of 0-5 volts, 0-10 volts or 4-20mA programs the output current from 0-100% of full scale. a) An input signal of 0-5 volts or 0-10 volts (user selectable with switch SW1-2) programs the output current from 0-100% of full scale. Signal return is at J4-12. b) An input signal of 4-20mA (with switch SW1-2 set to ON (1) position) programs the output current from 0-100% of full scale. Jumpers from J4-13 to J4-12 and J4-23 to J4-11 are also required. Signal return for the 4-20mA current is J4-23. OVP RESISTANCE PROGRAMMING OUTPUT: Pin-16, provides a 1mA current source which when connected to Pin-3, the OVP PROG INPUT, with a 0-10KΩ external resistor connected between Pin-16 and Pin-12, programs the OVP threshold from 5-110% of full scale output voltage. Switch SW1-3 must be set to ON (1) to select 0-5VDC input range. Note: The OVP input is programmed to 110% by an internal connection between the 1mA source on Pin-16 to a separate circuit. This allows the user to program remotely without having to provide a separate programming source or jumper to the OVP input. VOLTAGE RESISTANCE PROGRAMMING OUTPUT: Pin-21, provides a 1mA current source which when connected to Pin-9, the V PROG INPUT, with a 0-5KΩ external resistor connected between Pin-21 and Pin-12, programs the output voltage from 0-100% of full scale output. Switch SW1-1 must be set to ON (1) to select 0-5VDC input range. CURRENT RESISTANCE PROGRAMMING OUTPUT: Pin-22, provides a 1mA current source which when connected to Pin-10, the I PROG INPUT, with a 0-5KΩ external resistor connected between Pin-22 and Pin-12, programs the output current from 0-100% of full scale output. Switch SW1-2 must be set to ON (1) to select 0-5VDC input range. M51A Option 2-5

14 Isolated Analog Programmer Operation DLM-E Series and DCS-E Series Auxiliary Sources AUXILIARY DC OUTPUT: Pin-15, 16VDC source for use with logic and programming circuits. Source capability is adequate to provide for full scale programming of output voltage, current, or OVP when the user connects it to the appropriate programming input(s). Source is referenced to Pin-6. Can be used as a source for 4-20mA programming current. AUXILIARY DC RETURN: Pin-6, return for AUXILIARY source output. 4-20MA CURRENT PROGRAMMING OFFSET SIGNAL (-2.5VDC): Pin-8, provides a negative 2.5VDC to zero out the 4mA signal generated by internal circuits when using 4-20mA programming of output voltage. Jumpers to Pin MA CURRENT PROGRAMMING OFFSET SIGNAL (-2.5VDC): Pin-11, provides a negative 2.5VDC to offset the signal generated by internal circuits when using 4-20mA programming of output current. Jumpers to Pin M51A Option

15 DLM-E Series and DCS-E Series Isolated Analog Programmer Operation Remote Programming Configuration Voltage Source Programming of Output Voltage SW1 Switch Settings SW1-1 ON (1)= 0 5V SW1-1 OFF (0)= 0 10V Set up for voltage source programming of the output voltage as follows: 1. Set SW1-1, V PROG, to ON (1) for 0-5VDC programming range. 2. Set SW1-1, V PROG, to OFF (0) for 0-10VDC programming range. 3. Connect the external programming voltage source to the ISOLATED ANALOG PROGRAMMER connector, J4, with positive to Pin-9 and negative to Pin Connect Pin-1, ANALOG-CONTROL, of the ISOLATED ANALOG PROGRAMMER connector, J4, to Pin-2 to enable remote control. 5. Program the other parameters to the desired limit values. M51A Option 2-7

16 Isolated Analog Programmer Operation DLM-E Series and DCS-E Series Voltage Source Programming of Output Current SW1 Switch Settings SW1-2 ON (1) = 0 5V SW1-2 OFF (0)= 0 10V Set up for voltage source programming of the output voltage as follows: 1. Set SW1-2, I PROG, to ON (1) for 0-5VDC programming range. 2. Set SW1-1, V PROG, to OFF (0) for 0-10VDC programming range. 3. Connect the external programming voltage source to the ISOLATED ANALOG PROGRAMMER connector, J4, with positive to Pin-10 and negative to Pin Connect Pin-1, ANALOG-CONTROL, of the ISOLATED ANALOG PROGRAMMER connector, J4, to Pin-2 to enable remote control. 5. Program the other parameters to the desired limit values. 2-8 M51A Option

17 DLM-E Series and DCS-E Series Isolated Analog Programmer Operation Voltage Source Programming of OVP SW1 Switch Settings SW1-3 ON (1) = 0 5V SW1-3 OFF(0) = 0 10V Set up for voltage source programming of OVP as follows: 1. Set SW1-3, OVP PROG, to ON (1) for 0-5VDC programming range. 2. Set SW1-3, OVP PROG, to OFF (0) for 0-10VDC programming range. 3. Connect the external programming voltage source to the ISOLATED ANALOG PROGRAMMER connector, J4, with positive to Pin-5 and negative to Pin Connect Pin-1, ANALOG-CONTROL, of the ISOLATED ANALOG PROGRAMMER connector, J4, to Pin-2 to enable remote control. 5. Connect Pin 16, OVP RESISTANCE PROGRAMMING OUTPUT, of the ISOLATED ANALOG PROGRAMMER connector, J4, to Pin 6 to disable the default OVP programming connection. 6. Program the other parameters to the desired limit values. M51A Option 2-9

18 Isolated Analog Programmer Operation DLM-E Series and DCS-E Series Resistance Programming of Output Voltage SW1 Switch Settings SW1-1 ON (1) = 0 5K Set up for resistance programming of the output voltage as follows: 1. Set SW1-1, V PROG, to ON (1) for 0-5VDC programming range. 2. Connect the external programming resistance, 0-5kΩ, to the ISOLATED ANALOG PROGRAMMER connector, J4, from Pin-9 to Pin Connect a jumper from Pin-21 to Pin-9 to connect the 1mA current source. 4. Connect Pin-1, ANALOG-CONTROL, of the ISOLATED ANALOG PROGRAMMER connector, J4, to Pin-2 to enable remote control. 5. Program the other parameters to the desired limit values M51A Option

19 DLM-E Series and DCS-E Series Isolated Analog Programmer Operation Resistance Programming of Output Current SW1 Switch Settings SW1-2 ON (1) = 0 5K Set up for resistance programming of the output current as follows: 1. Set SW1-2, I PROG, to ON (1) for 0-5VDC programming range. 2. Connect the external programming resistance, 0-5kΩ, to the ISOLATED ANALOG PROGRAMMER connector, J4, from Pin-10 to Pin Connect a jumper from Pin-22 to Pin-10 to connect the 1mA current source. 4. Connect Pin-1, ANALOG-CONTROL, of the ISOLATED ANALOG PROGRAMMER connector, J4, to Pin-2 to enable remote control. 5. Program the other parameters to the desired limit values. M51A Option 2-11

20 Isolated Analog Programmer Operation DLM-E Series and DCS-E Series Resistance Programming of OVP SW1 Switch Settings SW1-3 ON (1) = 0 5K Set up for resistance programming of the output voltage as follows: 1. Set SW1-3, OVP PROG, to ON (1) for 0-5VDC programming range. 2. Connect the external programming resistance, 0-5KΩ, to the ISOLATED ANALOG PROGRAMMER connector, from Pin-3 to Pin Connect a jumper from Pin-3 to Pin-21 or Pin-22, (whichever one is available) to connect the 1mA current source. 4. Connect Pin-1, ANALOG-CONTROL, of the ISOLATED ANALOG PROGRAMMER connector, J4, to Pin-2 to enable remote control. 5. Program the other parameters to the desired limit values. 6. Connect Pin-16, OVP Default Programming Input, of the ISOLATED ANALOG PROGRAMMER connector (J4) to Pin-6 to disable the default OVP programming connection M51A Option

21 DLM-E Series and DCS-E Series Isolated Analog Programmer Operation mA Current Source Programming of Output Voltage SW1 Switch Settings SW1-1 ON (1) = 4-20mA 4-20mA Set up for 4-20 ma programming of the output voltage as follows: 1. Set SW1-1, V PROG, to ON (1) for 4-20mA programming range. 2. Connect the external programming current source to the ISOLATED ANALOG PROGRAMMER connector, J4, with the source to Pin-9 and the return to Pin Connect a jumper from Pin-25 to Pin-12 to connect the 4-20mA current sense resistors to common. 4. Connect a jumper from Pin 20 to Pin 8 to provide the negative 2.5VDC to zero out the 4mA signal generated by internal circuits. 5. Connect Pin-1, ANALOG-CONTROL, of the ISOLATED ANALOG PROGRAMMER connector, J4, to Pin-2 to enable remote control. 6. Program the other parameters to the desired limit values. M51A Option 2-13

22 Isolated Analog Programmer Operation DLM-E Series and DCS-E Series mA Current Source Programming of Output Current SW1 Switch Settings SW1-2 ON (1) = 4-20mA 4-20mA Set up for 4-20 ma programming of the output current as follows: 1. Set SW1-2, I PROG, to ON (1) for 4-20mA programming range. 2. Connect the external programming current source to the ISOLATED ANALOG PROGRAMMER connector, J4, with the source to Pin-10 and the return to Pin Connect a jumper from Pin-13 to Pin-12 to connect the 4-20mA current sense resistors to common. 4. Connect a jumper from Pin 23 to Pin 11 to provide the negative 2.5VDC to zero out the 4mA signal generated by internal circuits. 5. Connect Pin-1, ANALOG-CONTROL, of the ISOLATED ANALOG PROGRAMMER connector, J4, to Pin-2 to enable remote control. 6. Program the other parameters to the desired limit values M51A Option

23 DLM-E Series and DCS-E Series Isolated Analog Programmer Operation Programming the Shutdown Function GND V 14 Figure 2 3. Using Shutdown with a DC Input (Positive Logic) TTL Shutdown Set up for Shutdown input signal as follows: 1. Connect the shutdown signal source to the ISOLATED ANALOG PROGRAMMER connector, J4, with positive to Pin-14 and the return to Pin Set switch SW1-6 to select the desired logic as defined in the following table. Switch SW1-6 Setting Signal Level Output Condition OFF (0) = Negative Logic ON (1) = Positive Logic Low High High Low OFF ON OFF ON M51A Option 2-15

24 Isolated Analog Programmer Operation DLM-E Series and DCS-E Series Shutdown Application Contact Closure An external relay, whether normally open or normally closed, may be used to activate the Shutdown circuit. Either positive or negative logic may be used. Set up for Shutdown input signal as follows: 1. Connect one side of the external relay to pin 15 (+16 VDC Auxiliary Output) on connector J4. Connect the other side of the relay to pin 14 (Remote Shutdown Input). 2. Set rear panel DIP switch SW1-6 to select the desired circuit logic as defined in the following table. Relay Switch SW1-6 Setting Relay Coil State Output Normally Open Relay Normally Closed Relay ON (1) (Positive Logic) OFF (0) (Negative Logic) ON (1) (Positive Logic) OFF (0) (Negative Logic) Energized De-energized Energized De-energized Energized De-energized Energized De-energized OFF ON ON OFF ON OFF OFF ON Figure 2 4. Using Shutdown with Contact Closure of a Normally OPEN Relay (SW1-6 ON) 2-16 M51A Option

25 DLM-E Series and DCS-E Series Isolated Analog Programmer Operation Figure 2 5. Using Shutdown with Contact Closure of a Normally OPEN Relay (SW1-6 OFF) Figure 2 6. Using Shutdown with Contact Closure of a Normally CLOSED Relay (SW1-6 ON) M51A Option 2-17

26 Isolated Analog Programmer Operation DLM-E Series and DCS-E Series Local/Remote Application An external relay or switch may be used to select the Local/Remote function. 1. Connect one side of the contacts to Pin-15 (+16 VDC Auxiliary Output) on connector J4. Connect the other contact to Pin-2. Connect the wiper to Pin-1, Analog Control Input. 2. Remote operation results when Pin-1 is low (Pin 1-2) and local supply operation results when Pin-1 is high (Pin1-15) Remote Local Figure 2 7 Using Local/Remote Operation with Contact Closure 2-18 M51A Option

27 DLM-E Series and DCS-E Series Isolated Analog Programmer Operation 2.4 Remote Monitoring Analog signals are available for monitoring the output voltage and current. These signals vary proportionally to the output parameters, and have user selectable ranges of 0-5VDC, 0-10VDC, or 4-20mA for an output change from zero to full scale. Refer to Table 2 3 for information on configuring the monitors. Output Isolated Analog SW1 SETUP Switch Monitor Programmer Connector J4 Signal Range Signal Signal Return Position Setting Voltage Pin-19 Pin V MON ON (1) 0-10VDC Voltage Pin-19 Pin V MON OFF (0) 0-5VDC Voltage Pin-4 Pin-12 N/A N/A 4-20mA Current Pin-7 Pin I MON ON (1) 0-10VDC Current Pin-7 Pin I MON OFF (0) 0-5VDC Current Pin-24 Pin-12 N/A N/A 4-20mA Table 2 3. Remote Monitoring 2.5 Remote Digital Status Signals Digital signals are available for remote monitoring the operational status of the unit. Refer to Table 2 4 for information on the characteristics of the signals. Status Isolated Analog Interface Logic Levels (with No Indicator Connector J4 Signal Output Current) Output Resistance Signal Signal Return Asserted Not Asserted VOLTAGE- MODE Pin-5 Pin-6 5V 0V 1kΩ OVP Pin-17 Pin-6 5V 0V 1kΩ FAULT Pin-18 Pin-6 5V 0V 1kΩ Table 2 4. Remote Digital Status Signals M51A Option 2-19

OPERATING AND SERVICE MANUAL. Universal Interface Device 47

OPERATING AND SERVICE MANUAL. Universal Interface Device 47 OPERATING AND SERVICE MANUAL Universal Interface Device 47 MAGNA-POWER ELECTRONICS, INC. 39 ROYAL ROAD, FLEMINGTON, NJ 08822 May 24, 2012 SAFETY NOTICE Universal Interface Device 47 (UID46) connects

More information

OPERATING AND SERVICE MANUAL. Universal Interface Device 47

OPERATING AND SERVICE MANUAL. Universal Interface Device 47 OPERATING AND SERVICE MANUAL Universal Interface Device 47 MAGNA-POWER ELECTRONICS, INC. 39 ROYAL ROAD, FLEMINGTON, NJ 08822 May 24, 202 SAFETY NOTICE Universal Interface Device 47 (UID47) connects two

More information

STATUS Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

STATUS Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free Instruction Manual Model 1582-45L Data Switch September 2010, Rev A REMOTE LOCAL SWITCH STATUS SELECT REMOTE LOCAL LOCAL SELECT CHANNEL SELECT POWER MODEL 1582 SWITCH CROSS TECHNOLOGIES, INC. Data, drawings,

More information

User's Guide. Extech AM A AC Analog Clamp Meter

User's Guide. Extech AM A AC Analog Clamp Meter User's Guide Extech AM300 300A AC Analog Clamp Meter Introduction Congratulations on your purchase of the Extech AM300 Analog Clamp Meter. This device measure AC Voltage and Current, DC Voltage, and Resistance.

More information

OPERATING AND SERVICE MANUAL. Universal Interface Device 45

OPERATING AND SERVICE MANUAL. Universal Interface Device 45 OPERATING AND SERVICE MANUAL Universal Interface Device 45 MAGNA-POWER ELECTRONICS, INC. 81 FULTON STREET, BOONTON, NJ 07005 September 7, 2005 SAFETY NOTICE Universal Interface Device 45 (UID45) connects

More information

SIAC-PS 3G SIGNAL ISOLATOR WITH POWER SUPPLY (PART NO. 8890) INSTALLATION INSTRUCTIONS

SIAC-PS 3G SIGNAL ISOLATOR WITH POWER SUPPLY (PART NO. 8890) INSTALLATION INSTRUCTIONS SEE SAFETY WARNING ON PAGE 6 SIAC-PS 3G SIGNAL ISOLATOR WITH POWER SUPPLY IS DESIGNED TO BE USED WITH KBAC 3G SERIES DRIVES ONLY KBAC 3G SERIES MODELS CONTAIN THE "(3G)" DESIGNATOR ON THE PRODUCT LABEL

More information

The 3 kw Models will accept 200*/230 VAC single phase and 200*/208 VAC three phase input power.

The 3 kw Models will accept 200*/230 VAC single phase and 200*/208 VAC three phase input power. Sorensen DLM 3 & 4 kw Series DC Power Supply 3 4 kw 5 600 V 5 450 A 208 230 208 400 480 The Sorensen DLM 3kW and 4kW Series programmable DC power supplies are designed to provide highly stable, continuously

More information

PMDX-105 Quad Isolator Board

PMDX-105 Quad Isolator Board PMDX105 Quad Isolator Board User s Manual Date: 18 April 2011 PMDX Web: http://www.pmdx.com 9704D Gunston Cove Rd Phone: 1 (703) 3722975 Lorton, VA 220792366 USA FAX: 1 (703) 3722977 PMDX105_Manual_10.doc

More information

Model VT120 Fast Timing Preamplifier Operating and Service Manual

Model VT120 Fast Timing Preamplifier Operating and Service Manual Model VT120 Fast Timing Preamplifier Operating and Service Manual Printed in U.S.A. ORTEC Part No. 740360 1202 Manual Revision C Advanced Measurement Technology, Inc. a/k/a/ ORTEC, a subsidiary of AMETEK,

More information

DCM Digital Control Modules

DCM Digital Control Modules DCM Digital Control Modules TECHNICAL MANUAL Version 1.2 November 2011 Safety Precautions Caution Read Instructions: Read and understand all safety and operating instructions before using the equipment.

More information

Resolver to Digital Expansion Board

Resolver to Digital Expansion Board Resolver to Digital Expansion Board Catalog No. EXB009A01 Installation and Operating Manual 6/98 MN1313 Table of Contents Section 1 General Information............................. 1-1 Introduction....................................

More information

ACLD Channel Opto-isolated Digital Input Board

ACLD Channel Opto-isolated Digital Input Board ACLD-9182 16 Channel Opto-isolated Digital Input Board @ Copyright 1996 All Rights Reserved. Manual edition 01, January 1996 The information in this document is subject to change without prior notice in

More information

EASON TECHNOLOGY. IO8 & IO24 Break-Out Module

EASON TECHNOLOGY. IO8 & IO24 Break-Out Module EASON TECHNOLOGY IO8 & IO24 Break-Out Module p/n 50-00180-01 Revision1.2 Eason Technology, Inc. 7975 Cameron Dr. Bldg 300 Windsor, CA 95492 Phone (707) 837-0120 FAX (707) 837-2742 http://www.eason.com

More information

Agilent Technologies E5339A 38-Pin Low-Voltage Probe

Agilent Technologies E5339A 38-Pin Low-Voltage Probe Agilent Technologies E5339A 38-Pin Low-Voltage Probe Installation Note The 38-pin low-voltage probe provides a convenient way to connect two Agilent Technologies logic analyzer probe cables to a small

More information

PIM-Mini Pulsed Current Source Operation Manual

PIM-Mini Pulsed Current Source Operation Manual PIM-Mini Pulsed Current Source Operation Manual Directed Energy, Inc. 1609 Oakridge Dr., Suite 100, Fort Collins, CO 80525 (970) 493-1901 sales@ixyscolorado.com www.ixyscolorado.com Manual Document 7650-0007

More information

The EB7-4W plugs onto one- or two-channel speaker or headset stations as illustrated in Figure 1. EB7-4W. Option. 4-Wire. Option

The EB7-4W plugs onto one- or two-channel speaker or headset stations as illustrated in Figure 1. EB7-4W. Option. 4-Wire. Option KB/HB-Series INSTALLATION INSTRUCTIONS EB7-4W Module Installation Clear-Com s EB7-4W 4-Wire Option module can be added to the KB-702, KB- 702GM, KB-701, and HB-702 products. This option allows the speaker

More information

OPERATING MANUAL LOW-VOLTAGE DISCONNECT PANELS LVD400 & LVD600 SERIES

OPERATING MANUAL LOW-VOLTAGE DISCONNECT PANELS LVD400 & LVD600 SERIES PRICE: $25.00 LOW-VOLTAGE DISCONNECT PANELS LVD400 & LVD600 SERIES www.unipowertelecom.com Manual No. LVD-201-2 8/29/01/L46Man 2001 UNIPOWER Corp. All Rights Reserved UNIPOWER Telecom, Division of UNIPOWER

More information

Automated Tuner System Power Distribution Hub

Automated Tuner System Power Distribution Hub User Guide Automated Tuner System Power Distribution Hub Model MT1020B MT1020-340 (Rev B) 12/11 User Guide Automated Tuner System Power Distribution Hub Model MT1020B 2900 Inland Empire Boulevard Ontario,

More information

OPERATIONS MANUAL PCM-I/O48

OPERATIONS MANUAL PCM-I/O48 OPERATIONS MANUAL PCM-I/O48 NOTE: This manual has been designed and created for use as part of the WinSystems Technical Manuals CD and/or the WinSystems website. If this manual or any portion of the manual

More information

User's Guide. MiniTec TM Series Model MN25 MultiMeter

User's Guide. MiniTec TM Series Model MN25 MultiMeter User's Guide MiniTec TM Series Model MN25 MultiMeter Warranty EXTECH INSTRUMENTS CORPORATION warrants this instrument to be free of defects in parts and workmanship for one year from date of shipment (a

More information

PMDX-105. I/O Option Riser Board User s Manual. Document Revision: 1.1 Date: 7 September 2004 PCB Revision: PCB-443A

PMDX-105. I/O Option Riser Board User s Manual. Document Revision: 1.1 Date: 7 September 2004 PCB Revision: PCB-443A PMDX-105 I/O Option Riser Board User s Manual Date: 7 September 2004 PMDX Web: http://www.pmdx.com 7432 Alban Station Blvd., A105 Phone: +1 (703) 912-4991 Springfield, VA 22150-2321 USA FAX: +1 (703) 912-5849

More information

Omnitron Systems Technology, Inc. 1. iconverter. 19-Module Managed Power Chassis User s Manual

Omnitron Systems Technology, Inc. 1. iconverter. 19-Module Managed Power Chassis User s Manual Omnitron Systems Technology, Inc. 1 iconverter 19-Module Managed Power Chassis User s Manual 27 Mauchly, #201, Irvine, CA 92618 Phone: (949) 250-6510; Fax: (949) 250-6514 2 Omnitron Systems Technology,

More information

OP8/16 Optoisolated Digital Input Board User's Manual

OP8/16 Optoisolated Digital Input Board User's Manual OP8/16 Optoisolated Digital Input Board User's Manual Real Time Devices USA, Inc. Accessing the Analog World Publication No. OP16-9742 OP8/16 User's Manual REAL TIME DEVICES USA 820 North University Drive

More information

KBMG MULTI-SPEED BOARD

KBMG MULTI-SPEED BOARD TM INSTALLATION AND OPERATION MANUAL KBMG MULTI-SPEED BOARD KB Part No. 8833 Multi-Speed Board for KBMG Series Regenerative Drive Pending! See Safety Warning on Page 1 The information contained in this

More information

SIRIUS CAPACITOR MODULE User Manual. Model number: A-1.7C-M-SD-G Version 1.0; Release Date: April 2018

SIRIUS CAPACITOR MODULE User Manual. Model number: A-1.7C-M-SD-G Version 1.0; Release Date: April 2018 SIRIUS CAPACITOR MODULE User Manual Model number: 3550-48-A-1.7C-M-SD-G Version 1.0; Release Date: April 2018 Introduction The Sirius Capacitor Module ( Sirius ) is supercapacitor-based storage that uses

More information

INSTRUCTION MANUAL RA 19-7B RACK ADAPTER HOT SWAP RACK ADAPTER FOR HSF SERIES POWER SUPPLIES

INSTRUCTION MANUAL RA 19-7B RACK ADAPTER HOT SWAP RACK ADAPTER FOR HSF SERIES POWER SUPPLIES INSTRUCTION MANUAL RA 19-7B RACK ADAPTER HOT SWAP RACK ADAPTER FOR HSF SERIES POWER SUPPLIES KEPCO INC. An ISO 9001 Company. MODEL RA 19-7B RACK ADAPTER ORDER NO. REV. NO. IMPORTANT NOTES: 1) This manual

More information

INSTRUCTION MANUAL RA 19-6B RACK ADAPTER HOT SWAP RACK ADAPTER FOR HSF SERIES POWER SUPPLIES

INSTRUCTION MANUAL RA 19-6B RACK ADAPTER HOT SWAP RACK ADAPTER FOR HSF SERIES POWER SUPPLIES INSTRUCTION MANUAL RA 19-6B RACK ADAPTER HOT SWAP RACK ADAPTER FOR HSF SERIES POWER SUPPLIES KEPCO INC. An ISO 9001 Company. MODEL RA 19-6B RACK ADAPTER ORDER NO. REV. NO. IMPORTANT NOTES: 1) This manual

More information

Y K Modem Module

Y K Modem Module Y-308 56K Modem Module For use with Y-200 Series Electronic Boiler Sequencer & Outdoor Reset Control System Installation and Operating Manual CATALOG NO. 5000.65A Effective: 09-19-08 Replaces: 08-26-05

More information

INSTRUCTION MANUAL RA 19-5B RACK ADAPTER HOT SWAP RACK ADAPTER FOR HSF SERIES POWER SUPPLIES

INSTRUCTION MANUAL RA 19-5B RACK ADAPTER HOT SWAP RACK ADAPTER FOR HSF SERIES POWER SUPPLIES INSTRUCTION MANUAL RA 19-5B RACK ADAPTER HOT SWAP RACK ADAPTER FOR HSF SERIES POWER SUPPLIES KEPCO INC. An ISO 9001 Company. MODEL RA 19-5B RACK ADAPTER ORDER NO. REV. NO. IMPORTANT NOTES: 1) This manual

More information

iconverter 2-Module Power Chassis

iconverter 2-Module Power Chassis iconverter 2-Module Power Chassis User Manual 38 Tesla, Irvine, CA 92618 USA Phone: (949) 250-6510; Fax: (949) 250-6514 Page 1 Warning The operating description in this Instruction Manual is for use by

More information

User s Guide. 600A AC Clamp Meter. Model 38387

User s Guide. 600A AC Clamp Meter. Model 38387 User s Guide 600A AC Clamp Meter Model 38387 Safety International Safety Symbols This symbol, adjacent to another symbol or terminal, indicates the user must refer to the manual for further information.

More information

User s Guide. POWERVAR Single Phase Power Conditioners

User s Guide. POWERVAR Single Phase Power Conditioners POWERVAR Single Phase Power Conditioners User s Guide Industrial Conditioners GPI Series B Conditioners GPI Series 1 Conditioners 2-15 kva Single Phase Conditioners GPI Series 1 Conditioners RoHS Compliant

More information

Contents. HP E1586A Rack Mount Terminal Panel User s Manual

Contents. HP E1586A Rack Mount Terminal Panel User s Manual Contents HP E1586A Rack Mount Terminal Panel User s Manual Description... 5 Connecting to VXIbus Instruments... 5 Interconnect Cables... 5 Terminal Block Connections... 6 Using the Terminal Panel for Reference

More information

USER MANUAL CCHP-6000-XX 6kJ/s Capacitor Charging Power Supply

USER MANUAL CCHP-6000-XX 6kJ/s Capacitor Charging Power Supply 26 Ward Hill Ave., Bradford, MA 01835 Phone: 978-241-8260 Fax: 978-241-8262 USER MANUAL CCHP-6000-XX 6kJ/s Capacitor Charging Power Supply 02001235 Rev 1 CCHP-6000-XX User Manual Page 1 of 14 Table of

More information

700 Series 200 Amp Clamp Meters

700 Series 200 Amp Clamp Meters 700 Series 200 Amp Clamp Meters #61-700 #61-701 #61-702 1 2 3 6 5 7 4 8 1. Non-contact voltage (NCV) (#61-701 and #61-702) With the NCV tab on the tip of the clamp close to an AC voltage, press the NCV

More information

CM Mpixel CMOS Imaging Camera

CM Mpixel CMOS Imaging Camera CM130 1.3Mpixel CMOS Imaging Camera Technical Reference Guide PCB Rev 1.0 www.soc-robotics.com Copyright 2009. SOC Robotics, Inc. 1 Manual Rev 0.90 Warranty Statement SOC Robotics warrants that the Product

More information

PMDX-108-Output. 8-Channel Isolated Output Board for PC parallel port pins 2-9. User s Manual

PMDX-108-Output. 8-Channel Isolated Output Board for PC parallel port pins 2-9. User s Manual PMDX-108-Output 8-Channel Isolated Output Board for PC parallel port pins 2-9 User s Manual Date: 25 February 2010 PMDX Web: http://www.pmdx.com 9704-D Gunston Cove Rd Phone: +1 (703) 372-2975 Lorton,

More information

OPERATING PROCEDURES for the UPS-S2 Universal Power Supply Series 2

OPERATING PROCEDURES for the UPS-S2 Universal Power Supply Series 2 OPERATING PROCEDURES for the Universal Power Supply Series 2 Vanguard Instruments Co., Inc. 1520 S. Hellman Ave. Ontario, California 91761 TEL: 909-923-9390 November 2013 FAX: 909-923-9391 REV. 2 SAFETY

More information

FDCCM1-MM-L & FDCCM1-MM-R

FDCCM1-MM-L & FDCCM1-MM-R Page 1 of 14 Installation and Operation Manual FDCCM1-MM-L & FDCCM1-MM-R MULTI-MENU CABIN CONTROL MODULE - WITH AUDIO (LEFT & RIHT) Page 2 of 14 FDCCM1-MM-L & FDCCM1-MM-R Multi-Menu Cabin Control Module

More information

Model 7705 Control Module

Model 7705 Control Module www.keithley.com Model 7705 Control Module User s Guide PA-696 Rev. D / October 2006 A G R E A T E R M E A S U R E O F C O N F I D E N C E Safety Precautions The following safety precautions should be

More information

INSTRUCTION MANUAL RA 19-4B RACK ADAPTER HOT SWAP RACK ADAPTER FOR HSF SERIES POWER SUPPLIES

INSTRUCTION MANUAL RA 19-4B RACK ADAPTER HOT SWAP RACK ADAPTER FOR HSF SERIES POWER SUPPLIES INSTRUCTION MANUAL RA 19-4B RACK ADAPTER HOT SWAP RACK ADAPTER FOR HSF SERIES POWER SUPPLIES KEPCO INC. An ISO 9001 Company. MODEL RA 19-4B RACK ADAPTER ORDER NO. REV. NO. IMPORTANT NOTES: 1) This manual

More information

TDM-170 TIMER DISPLAY

TDM-170 TIMER DISPLAY TDM-170 TIMER DISPLAY TECHNICAL MANUAL Version 1.1 August 2016 TDM-170 Timer Display Technical Manual Safety Precautions Caution Read Instructions: Read and understand all safety and operating instructions

More information

PMDX-103. Parallel Port Isolator Board. User s Manual. Document Revision: 1.2 Date: 20 February 2007 PCB Revision: PCB-447B

PMDX-103. Parallel Port Isolator Board. User s Manual. Document Revision: 1.2 Date: 20 February 2007 PCB Revision: PCB-447B PMDX-103 Parallel Port Isolator Board User s Manual Date: 20 February 2007 PMDX Web: http://www.pmdx.com 9704-D Gunston Cove Rd Phone: +1 (703) 372-2975 Lorton, VA 22079-2366 USA FAX: +1 (703) 372-2977

More information

LINE VOLTAGE TESTER CT101 USER S MANUAL. Please read this manual carefully and thoroughly before using this product.

LINE VOLTAGE TESTER CT101 USER S MANUAL. Please read this manual carefully and thoroughly before using this product. LINE VOLTAGE TESTER USER S MANUAL CT101 Please read this manual carefully and thoroughly before using this product. KEY FEATURES Visual indication of AC or DC voltage Easy to use approved Safe for CAT

More information

Sorensen DLM 600 Series W V 2 75 A. Half Rack Programmable DC Power Supply

Sorensen DLM 600 Series W V 2 75 A. Half Rack Programmable DC Power Supply Sorensen DLM 600 Series Half Rack Programmable DC Power Supply High Power Density: 600 watts in 1U (1.75 inches) high, half rack (8.5 inches) wide; no top or bottom clearance spacing required. Near Linear

More information

Tornado F-5. Motor Backspin Detect Relay And Probe For F-5 Motor Controller

Tornado F-5. Motor Backspin Detect Relay And Probe For F-5 Motor Controller Tornado F-5 Motor Backspin Detect Relay And Probe For F-5 Motor Controller Tornado F-5 Motor Backspin Detection Relay And Probe Revision 8.1 Change Log: Rev 8.1 Apr 24 2012 JNesbitt@GPS-US.co GPS updates

More information

SATA II HDD Canister KISS DA 435 Quick Reference Guide

SATA II HDD Canister KISS DA 435 Quick Reference Guide SATA II HDD Canister KISS DA 435 Quick Reference Guide If it s embedded, it s Kontron 1. Table of Contents SATA II HDD Canister KISS DA 435 1. Table of Contents 1. Table of Contents... 1 2. Important Information...

More information

User Guide. DMXSM-H18 Splitter. DMXSM-H81 Merger. Document Release Aug Revision B

User Guide. DMXSM-H18 Splitter. DMXSM-H81 Merger. Document Release Aug Revision B User Guide DMXSM-H18 Splitter DMXSM-H81 Merger Document Release Aug. 2008 Revision B Warranty Leviton Manufacturing Co Inc. warrants this device to be free of material and workmanship defects for a period

More information

3-4 SAS/SATA II HDD Canister Entry version USER S MANUAL XC-34D1-SA10-0-R. Document number: MAN A

3-4 SAS/SATA II HDD Canister Entry version USER S MANUAL XC-34D1-SA10-0-R. Document number: MAN A 3-4 SAS/SATA II HDD Canister Entry version XC-34D1-SA10-0-R USER S MANUAL Document number: MAN-00077-A ii Preface Important Information Warranty Our product is warranted against defects in materials and

More information

MAXIMA+ Series Rotary Level Indicator

MAXIMA+ Series Rotary Level Indicator MAXIMA+ Series Rotary Level Indicator BinMaster: Division of Garner Industries 7201 N. 98th St., Lincoln, NE 68507 402-434-9102 email: info@binmaster.com www.binmaster.com OPERATING INSTRUCTIONS PLEASE

More information

Relay Board. User Manual. 1.0, Oct 2013

Relay Board. User Manual. 1.0, Oct 2013 Relay Board User Manual 1.0, Oct 2013 This work is licensed under the Creative Commons Attribution-Share Alike 2.5 India License. To view a copy of this license, visit http://creativecommons.org/licenses/by-sa/2.5/in/

More information

TDM-150 TIMER DISPLAY

TDM-150 TIMER DISPLAY TDM-150 TIMER DISPLAY TECHNICAL MANUAL Covers TDM-150D, TDM-150F Version 1.1 August 2016 Safety Precautions Caution Read Instructions: Read and understand all safety and operating instructions before using

More information

MiT. MOVING image TECHNOLOGIES INSTRUCTIONS FOR INSTALLATION, OPERATION, AND MAINTENANCE

MiT. MOVING image TECHNOLOGIES INSTRUCTIONS FOR INSTALLATION, OPERATION, AND MAINTENANCE MiT MOVING image TECHNOLOGIES INSTRUCTIONS FOR INSTALLATION, OPERATION, AND MAINTENANCE OF A-LMS 24 Architectural Lighting Management System Part number A000230-xxx Manual Version 1.0 MOVING image TECHNOLOGIES,

More information

4300 WINDFERN RD #100 HOUSTON TX VOICE (713) FAX (713) web: IMPORTANT!!!

4300 WINDFERN RD #100 HOUSTON TX VOICE (713) FAX (713) web:   IMPORTANT!!! 4300 WINDFERN RD #100 HOUSTON TX 77041-8943 VOICE (713) 973-6905 FAX (713) 973-9352 web: www.twrlighting.com IMPORTANT!!! PLEASE TAKE THE TIME TO FILL OUT THIS FORM COMPLETELY. FILE IT IN A SAFE PLACE.

More information

CM68 4 Channel NTSC/PAL Video Decoder

CM68 4 Channel NTSC/PAL Video Decoder CM68 4 Channel NTSC/PAL Video Decoder Technical Reference Guide PCB Rev 1.0 www.soc-robotics.com Copyright 2009. SOC Robotics, Inc. 1 Manual Rev 0.90 Warranty Statement SOC Robotics warrants that the Product

More information

OPERATIONS MANUAL PCM-DOC

OPERATIONS MANUAL PCM-DOC OPERATIONS MANUAL PCM-DOC NOTE: This manual has been designed and created for use as part of the WinSystems Technical Manuals CD and/or the WinSystems website. If this manual or any portion of the manual

More information

PCLD-8751 PCLD User Manual

PCLD-8751 PCLD User Manual PCLD-8751 48-Channel Opto-isolated D/I Board PCLD-8761 24-Channel Opto-isolated D/I and 24-Channel Relay Board User Manual Copyright The documentation and the software included with this product are copyrighted

More information

VIP-804 QUAD ENHANCED NETWORK AUDIO PORT

VIP-804 QUAD ENHANCED NETWORK AUDIO PORT ISSUE 6 VIP-804 QUAD ENHANCED NETWORK AUDIO PORT INTRODUCTION The VIP-804 Quad Enhanced Network Audio Port enables voice access to four zones of one-way paging over an IP network, allowing page zones to

More information

TB-24P/24R/16P8R. Relay Outputs or Isolated Inputs Terminal Board Series

TB-24P/24R/16P8R. Relay Outputs or Isolated Inputs Terminal Board Series TB24P/24R/16P8R Relay Outputs or Isolated Inputs Terminal Board Series @Copyright 1995~1998 ADLink Technology Inc. All Rights Reserved. Manual first edition: 15, August 1995 Manual second edition: 01,

More information

TC1880 Series. 4/5/6/8 Channel RS-232 FIBER OPTIC MICRO MUX User's Manual

TC1880 Series. 4/5/6/8 Channel RS-232 FIBER OPTIC MICRO MUX User's Manual Series 4/5/6/8 Channel RS-232 FIBER OPTIC MICRO MUX MODEL: S/N: DATE: Notice! Although every effort has been made to insure that this manual is current and accurate as of date of publication, no guarantee

More information

Global Water Instrumentation, Inc.

Global Water Instrumentation, Inc. Instrumentation, Inc. 11390 Amalgam Way Gold River, CA 95670 T: 800-876-1172 Int l: (916) 638-3429, F: (916) 638-3270 Display: EZ100 11/12/04-1 - Congratulations on your purchase of the EZ100 Display.

More information

4300 WINDFERN RD #100 - HOUSTON TX VOICE (713) FAX (713) web: IMPORTANT!!!

4300 WINDFERN RD #100 - HOUSTON TX VOICE (713) FAX (713) web:   IMPORTANT!!! 4300 WINDFERN RD #100 - HOUSTON TX 77041-8943 VOICE (713) 973-6905 - FAX (713) 973-9352 web: www.twrlighting.com IMPORTANT!!! PLEASE TAKE THE TIME TO FILL OUT THIS FORM COMPLETELY. FILE IT IN A SAFE PLACE.

More information

PCM-7140 Pulsed Current Source Operation Manual

PCM-7140 Pulsed Current Source Operation Manual PCM-7140 Pulsed Current Source Operation Manual Directed Energy, Inc. 1609 Oakridge Dr., Suite 100, Fort Collins, CO 80525 (970) 493-1901 sales@ixyscolorado.com www.ixyscolorado.com Manual Document 7650-0031

More information

IOX-4. Installation Instructions. AXS-100 I/O Expander 1. INTRODUCTION 2. SPECIFICATIONS 3. MOUNTING DE6314 1

IOX-4. Installation Instructions. AXS-100 I/O Expander 1. INTRODUCTION 2. SPECIFICATIONS 3. MOUNTING DE6314 1 AXS-100 I/O Expander 1. INTRODUCTION The is an input / output expander for the AXS-100 access control panel. It contains eight analog inputs and eight dry contact relays output. Up to four boards may be

More information

Profibus DP Expansion Board

Profibus DP Expansion Board Profibus DP Expansion Board Catalog No. EXBD04 Installation and Operating Manual 10/02 MN1393 Table of Contents Section 1 General Information................................................... 1 1 Introduction.......................................................

More information

VIP-812A DUAL NETWORKED STATION PORT

VIP-812A DUAL NETWORKED STATION PORT ISSUE 1 VIP-812A DUAL NETWORKED STATION PORT INTRODUCTION The VIP-812A Dual Networked Station Port allows most loop start terminal devices to be connected to a managed IP-based LAN/WAN. SPECIFICATIONS

More information

POWER SERIES Plus. 3 in 1 AC Voltage. Digital Switchboard Meter. User s Manual IM2493VVV-2

POWER SERIES Plus. 3 in 1 AC Voltage. Digital Switchboard Meter. User s Manual IM2493VVV-2 POWER SERIES Plus 3 in 1 AC Voltage Digital Switchboard Meter User s Manual General Description The POWER SERIES Plus digital switchboard meters incorporate the latest DSP microprocessor technology. Careful

More information

Surge Protective Devices Installation, Operation and Maintenance Manual. LoadTrack LTL

Surge Protective Devices Installation, Operation and Maintenance Manual. LoadTrack LTL LoadTrack LTL Surge Protective Devices Installation, Operation and Maintenance Manual P.O. Box 3760 Winter Park, FL 32790 USA TEL: 800-647-1911 www.tpssurge.com LOADTRACK LTL INSTALLATION, OPERATION AND

More information

Proliphix EPA-60 Installation Guide

Proliphix EPA-60 Installation Guide Proliphix EPA-60 Installation Guide Rev 1.2 Page 2 of 5 Installation CAUTION THE EPA-60 SHOULD ONLY BE POWERED WITH THE PROLIPHIX POWER SUPPLY INCLUDED WITH THE EPA-60. DO NOT POWER THE EPA-60 WITH ANY

More information

Sonic Ruptor 400. User Manual

Sonic Ruptor 400. User Manual Sonic Ruptor 400 User Manual Data herein has been verified and validated. It is believed adequate for the intended use of the instrument. If the instrument or procedures are used for purposes over and

More information

Atlas. GPI Smart Matrix. User Manual

Atlas. GPI Smart Matrix. User Manual Atlas GPI Smart Matrix User Manual November 22, 2017 JLCooper Atlas is a trademark of JLCooper Electronics. All other brand names are the property of their respective owners. Atlas User Manual, November

More information

OPR Power Series AC to DC POWER SUPPLY SERIES WITH REMOTE MANAGEMENT AND ALARM SYSTEMS. Model Nos. OPR065-48S / OPR065-48R. Manual

OPR Power Series AC to DC POWER SUPPLY SERIES WITH REMOTE MANAGEMENT AND ALARM SYSTEMS. Model Nos. OPR065-48S / OPR065-48R. Manual OPR Power Series AC to DC POWER SUPPLY SERIES WITH REMOTE MANAGEMENT AND ALARM SYSTEMS Model Nos. OPR065-48S / OPR065-48R Manual Revision F July 2009 Optimal Power Supplies LLC www.optimal-power.com i

More information

Plus-X 300. Installation and Operation Manual

Plus-X 300. Installation and Operation Manual Plus-X 300 Installation and Operation Manual Table of Contents Introduction... 1 Compatibility... 1 Installation... 1 Configuration... 2 Operation... 5 Getting Help... 6 Warranty... 6 Appendix A: Specifications...

More information

Wasp Embedded Controller

Wasp Embedded Controller Wasp Embedded Controller Wasp16/32/64 Hardware Reference Guide PCB Rev 1.0 WASP16 WASP32 WASP64 MC433 Hardware Reference Guide Manual Revision 0.85 Table of Contents Warranty Statement...2 1.0 Introduction....4

More information

Model 3526-B Digi-Probe Multimeter

Model 3526-B Digi-Probe Multimeter Model 3526-B Digi-Probe Multimeter CAUTION: Read, understand and follow all Safety Rules and Operating Instructions in this instruction manual before using this product. 84-797 Rev A The Model 3526-B has

More information

Lx \ Ls Series AC Power Source IVI Instrument Driver Manual LabView, LabWindows/CVI

Lx \ Ls Series AC Power Source IVI Instrument Driver Manual LabView, LabWindows/CVI Lx \ Ls Series AC Power Source IVI Instrument Driver Manual LabView, LabWindows/CVI Contact Information Telephone: 800 733 5427 (toll free in North America) 858 450 0085 (direct) Fax: 858 458 0267 Email:

More information

1-36V, 0-3A DC Power Supply

1-36V, 0-3A DC Power Supply 1550 1-36V, 0-3A DC Power Supply User Manual Safety Summary The following safety precautions apply to both operating and maintenance personnel and must be followed during all phases of operation, service,

More information

Analog Interface Unit Operation Manual

Analog Interface Unit Operation Manual Analog Interface Analog Interface Unit Operation Manual WARRANTY Accurate Technology, Inc. warrants the product against defective parts and workmanship for 1 year commencing from the date of original purchase.

More information

SOLVES-IT! 4 CHANNEL TIMER APPLICATION MODULE

SOLVES-IT! 4 CHANNEL TIMER APPLICATION MODULE SI-APPMOD-Times4 SOLVES-IT! 4 CHANNEL TIMER APPLICATION MODULE Revision 0 for Software Version 1.0.0.0 PLC on a Chip Patent 7,299,099 A larger format of this manual may be found at http://www.divelbiss.com

More information

SORENSEN ONE-YEAR WARRANTY

SORENSEN ONE-YEAR WARRANTY SORENSEN ONE-YEAR WARRANTY Sorensen, a division of Elgar Electronics Corporation, warrants its products to be free from defects in material and workmanship. This warranty is effective for one year from

More information

Card Nest Universal 12 position card nest for all K-AB cards above and all other K-AB cards.

Card Nest Universal 12 position card nest for all K-AB cards above and all other K-AB cards. Installation And Operation BASIC A/B SWITCHES K-AB-D25 K-AB-M34 SCOPE OF THIS DOCUMENT This document covers the following models: K-AB-D25 K-AB-D25-R K-AB-M34 K-AB-M34-R For the purposes of clarity, all

More information

Series 8000 RF Signal Switch Solution

Series 8000 RF Signal Switch Solution RF Signal Switch Solution Operation Manual Operation Manual, Part Number 07508000-006, Rev. A, May 17, 2013 All technical data and specifications in this publication are subject to change without prior

More information

User s Guide. 600A True RMS AC/DC Clamp Meter. Model 38389

User s Guide. 600A True RMS AC/DC Clamp Meter. Model 38389 User s Guide 600A True RMS AC/DC Clamp Meter Model 38389 Safety International Safety Symbols This symbol, adjacent to another symbol or terminal, indicates the user must refer to the manual for further

More information

VE8014A/VE8014AR QUAD NETWORKED STATION PORT

VE8014A/VE8014AR QUAD NETWORKED STATION PORT ISSUE 2 VE8014A/VE8014AR QUAD NETWORKED STATION PORT INTRODUCTION The VE8014A/VE8014AR Quad Networked Station Port allows most loop start terminal devices to be connected to a managed IP-based LAN/WAN.

More information

SmartBoom PRO PHS-SB100-4F, PHS-SB100-5M, PHS-SB100-U, PHS-SB200-4F, PHS-SB200-5M, PHS-SB200-U. Operating Manual

SmartBoom PRO PHS-SB100-4F, PHS-SB100-5M, PHS-SB100-U, PHS-SB200-4F, PHS-SB200-5M, PHS-SB200-U. Operating Manual SmartBoom Operating Manual PRO PHS-SB100-4F, PHS-SB100-5M, PHS-SB100-U, PHS-SB200-4F, PHS-SB200-5M, PHS-SB200-U Thank You We at Pliant Technologies, LLC want to thank you for purchasing the SmartBoom PRO

More information

Model 2460-KIT. Screw Terminal Connector Kit. Description / September 2014 *P * 1

Model 2460-KIT. Screw Terminal Connector Kit. Description / September 2014 *P * 1 Keithley Instruments 28775 Aurora Road Cleveland, Ohio 44139 1-800-935-5595 http://www.keithley.com Model 2460-KIT Screw Terminal Connector Kit Description The Model 2460-KIT Screw Terminal Connector Kit

More information

SNT-E RT 10.4 VGA TFT with Touch Screen Display Module Powered By SegeNT embedded GUI Board Hardware Manual

SNT-E RT 10.4 VGA TFT with Touch Screen Display Module Powered By SegeNT embedded GUI Board Hardware Manual HAIDAR TECHNOLOGY, LLC. The Next Generation Of Intelligent Embedded GUI Systems WWW.haidartechnology.com (614) 389-3022 Sales@haidartechnology.com SNT-E640480-104-RT 10.4 VGA TFT with Touch Screen Display

More information

PMDX-170 Slotted Optical Sensor

PMDX-170 Slotted Optical Sensor PMDX-170 Slotted Optical Sensor User s Manual Date: 20 May 2009 PMDX Web: http://www.pmdx.com 9704-D Gunston Cove Rd Phone: +1 (703) 372-2975 Lorton, VA 22079-2366 USA FAX: +1 (703) 372-2977 PMDX-170_Manual_10.doc

More information

DeviceNet Expansion Board

DeviceNet Expansion Board DeviceNet Expansion Board Catalog No. EXBD05 Installation and Operating Manual 10/02 Table of Contents Section 1 General Information................................................... 1 1 Introduction.......................................................

More information

FA-2448 SIX POSITION Filter Wheel

FA-2448 SIX POSITION Filter Wheel 15 Discovery Way, Acton, MA 01720 Phone: (978)263-3584, Fax: (978)263-5086 Web Site: www.acton-research.com Operating Instructions Acton Research Corporation FA-2448 SIX POSITION Filter Wheel Rev. 3.05.17

More information

XBDM. 1015LV, 1020LV, 1030LV, 1020HV Models USER & INSTALLATION MANUAL BYPASS DISTRIBUTION MODULE

XBDM. 1015LV, 1020LV, 1030LV, 1020HV Models USER & INSTALLATION MANUAL BYPASS DISTRIBUTION MODULE XBDM 1015LV, 1020LV, 1030LV, 1020HV Models USER & INSTALLATION MANUAL www.xpcc.com 2013 Xtreme Power Conversion Corporation. All rights reserved. Table of Contents IMPORTANT SAFETY INSTRUCTIONS:... 4 INTRODUCTION...

More information

87421/22A Power Supply. Operating and Service Manual

87421/22A Power Supply. Operating and Service Manual 87421/22A Power Supply Operating and Service Manual Agilent Part Number: 87421-90001 Printed in USA April 2001 Supersedes: September 1998 Notice The information contained in this document is subject to

More information

ADDENDUM BUS EXPANSION CARD FOR ADAM INTERCOM SYSTEM

ADDENDUM BUS EXPANSION CARD FOR ADAM INTERCOM SYSTEM ADDENDUM BUS EXPANSION FOR ADAM INTERCOM SYSTEM 9380-7532-000 Rev B, 6/97 PROPRIETARY ICE The RTS product information and design disclosed herein were originated by and are the property of Telex Communications,

More information

INSTRUCTION MANUAL. Model True RMS AC/DC 30A Mini Clamp-on Meter. Introduction. True RMS AC Current and Voltage

INSTRUCTION MANUAL. Model True RMS AC/DC 30A Mini Clamp-on Meter. Introduction. True RMS AC Current and Voltage INSTRUCTION MANUAL Model 380942 True RMS AC/DC 30A Mini Clamp-on Meter True RMS AC Current and Voltage Measure low current with high resolution to 0.1mA AC and 1mA DC Auto Power Off One touch DCA zero

More information

MAXIMA + Series ROTARY LEVEL CONTROL

MAXIMA + Series ROTARY LEVEL CONTROL Price $5.00 MAXIMA + Series ROTARY LEVEL CONTROL OPERATING INSTRUCTIONS PLEASE READ CAREFULLY Division of Garner Industries 7201 North 98th Street Lincoln, NE 68507-9741 (402) 434-9102 925-0268 Rev. A

More information

Integrated Stepper Drive & Motor

Integrated Stepper Drive & Motor SMD23 Integrated Stepper Drive & Motor Manual #: 940-0S050 User Manual AMCI Motion Control Products Important User Information The products and application data described in this manual are useful in a

More information

PSI DITHERLESS BIAS CONTROLLER USER GUIDE

PSI DITHERLESS BIAS CONTROLLER USER GUIDE PSI-0404-11 DITHERLESS BIAS CONTROLLER USER GUIDE Rev D Photonic Systems, Inc. Tel: 978-670-4990 900 Middlesex Turnpike Fax: 978-670-2510 Building #5 www.photonicsinc.com Billerica, MA 01821 1 DOCUMENT

More information

User's Guide. Model High Precision Quad Output DC Power Supply

User's Guide. Model High Precision Quad Output DC Power Supply User's Guide Model 382270 High Precision Quad Output DC Power Supply Introduction Congratulations on your purchase of the Extech 382270 DC Power Supply. The Model 382270 can be used for many applications

More information

MTS-2000 USER S MANUAL

MTS-2000 USER S MANUAL MTS-2000 USER S MANUAL USER s MANUAL - March 2010 MTS-2000 METER TEST SYSTEM Pay special attention to the warnings and safety instructions that accompany the above symbol wherever it is found within this

More information

POWER SERIES Plus Watt / VAR / Power Factor Digital Switchboard Meter User s Manual IM2493WVP-3

POWER SERIES Plus Watt / VAR / Power Factor Digital Switchboard Meter User s Manual IM2493WVP-3 POWER SERIES Plus Watt / VAR / Power Factor Digital Switchboard Meter User s Manual General Description The POWER SERIES Plus digital switchboard meters incorporate the latest DSP microprocessor technology.

More information