C-DIAS-Temperature Recording module CAI x Temp. inputs 50 C to +150 C
|
|
- Jemima Melton
- 3 years ago
- Views:
Transcription
1 C-DIAS-Temperature Recording module CAI x Temp. inputs 50 C to +150 C This analog input module is used to record temperatures from 50 C to +150 C with a PT 100 temperature sensor. Technical Data Analog channel specifications Number of channels 8 Measurement range -50 C to +150 C Sensor range 80,31 Ohm 157,31 Ohm Measurement values Open inputs supply 4095 Resolution 12 Bit Conversion time per channel 14 µs Applicable sensor type PT 100 Input filter 0,5 s Low pass 3. system Measurement accuracy of Analog channels ±0,7 % of the maximum measurement value Page 1
2 Electrical requirements Supply from C-DIAS-Bus +5 V and +24 V Current consumption on C-DIAS- Bus (+5 V supply) Current consumption on C-DIAS- Bus (+24 V supply) Typically 10 ma Typically 50 ma Maximum 20 ma Maximum 70 ma Miscellaneous Article number Hardware version 1.x Standardization UL (E247993) Environmental conditions Storage temperature C Operating temperature C Humidity EMV stability 0 95 %, uncondensed According to EN (Industry area) Shock resistance EN m/s² Protection type EN IP 20 Page 2 b
3 Mechanical Dimensions C-DIAS TEMPERATURE RECORDING MODULE CAI ,10 (measurement incl. Cover) 109, , Page 3
4 Connector Layout Page
5 X1: Temperature input connector 1-3 C-DIAS TEMPERATURE RECORDING MODULE CAI Pin Function 1 Temperature input 1-2 Temperature input 1+ 3 Temperature input 2-4 Temperature input 2+ 5 Temperature input 3-6 Temperature input 3+ X2: Temperature input connector Pin Function 1 Temperature input 4-2 Temperature input 4+ 3 Temperature input 5-4 Temperature input 5+ 5 Temperature input 6-6 Temperature input 6+ X3: Temperature input connector Pin Function 1 Temperature input 7-2 Temperature input 7+ 3 Temperature input 8-4 Temperature input 8+ 5 Do not use 6 Do not use Page 5 a
6 Applicable connectors X1-X3: 6-pin. Weidmüller connector B2L3,5/6 The complete C-DIAS connector set is available at Sigmatek under the article number Page
7 Wiring Guidelines The signals received by the analog module are small in comparison to the digital signals. To ensure error-free operation, a careful wiring technique must be followed. The 0 V connection to the voltage supply must be connected to the 0 V collection point over the shortest route possible. Connection lines to the analog inputs must be as short as possible and parallel connections to digital signal lines must be also be avoided. The signal lines should be 2-pin or 3-pin shielded wire or at least twisted pair Page 7
8 Direct connection to the thermal element of the control. PT 100 Fühler Schirmung 0 V-Schiene 2 6 Temp+ Temp- 1 5 Note: Temperature measurement with thermal resistors 2-wire measurement For 2-wire measurement, a short sensor line is recommended since the resistance of the wire influences the measurement. Page
9 Addressing Address Access Function 16#00 READ WORD Temperature measurement value 16#02 READ BYTE Bit 0 : AD-converter ready 16#00 WRITE BYTE Bit 0-2: channel select temp. input 000 Channel Channel Channel Channel Channel Channel Channel Channel 8 Bit 3 : 0 Bit 4 : 1 Bit 5 : 0 Bit 6 : 1 Bit 7 : 0 For the hardware calibration, the values for offset, multiplier and divisor are determined at the manufacturer. These values are stored in a serial EEPROM found in the module Page 9
10 Data in the EEPROM Module data (organized by byte) Address Data Description $00 $xx Checksum $ Identification $02 5 Module group 5 = CAI $03 11 Variant 11 = CAI088 $04 8 Number of channel $05 $1x Hardware version $10 = HW-V1.0, $11 = HW-V1.1, $10 Serial number AI Calibration Data (organized by Word) Address Data Description $40 $xxxx Checksum $ Identification $44 25 Length of the following data block in word $46 $0008 Number of channels (8x AI) $ Offset for 0 C Channel -1 $4A I.e Gain Multiplier Channel -1 $4C 3458 Gain Divisor Channel -1 $4E - $52 - Calibration values Channel -2 $54 - $58 - Calibration values Channel -3 $5A - $5E - Calibration values Channel -4 $60 - $64 - Calibration values Channel -5 $66 - $6A - Calibration values Channel-6 $6C - $70 - Calibration values Channel-7 $72 - $76 - Calibration values Channel-8 Calculation for the analog input values I.e.: Offset -143 Gain multiplicand 4000 Gain divisor 3458 Page 10 a
11 Conversion formula for the analog inputs C-DIAS TEMPERATURE RECORDING MODULE CAI 088 Value = (Analog input value - Offset) * Gain multiplicand / Gain divisor Example I.e.: value for -50 C: ( ) * 4000 / 3458 = 0000 value for +150 C: ( ) * 4000 / 3458 = Page 11
12 Operating diagram Reading analog channels Wandlung auf gewünschten Kanal starten Adresse 16#00 Status der Wandlung auslesen Adresse 16#02 nicht fertig Bit testen ob Wandlung fertig fertig Analogwert auslesen Adresse 16#00 16#01 Page
13 Interpolation table for the FeCuNi(j) DIN thermal filter C BITS -50,0 0-45,2 1-40,4 2-35,6 3-30, ,2 6-16,4 7-11,5 8-6,6 9-1,7 10 3,2 11 8, , , , , , , , , , , , , , , , , , , , , , , , , , , , , Page 13
14 Page
Technical Data. C-DIAS-MULTI l/o MODULE CIO 013
C-DIAS-MULTI l/o MODULE CIO 013 C-DIAS-Multi I/O Module CIO 013 6 x digital inputs (+24V, 5mA, 5ms) input 3 useable as interrupt (+24V, 5mA, 10 s) 2 x digital counter inputs (+5V, 5mA, 1 s) 8 x digital
C-DIAS Analogue Conversion Module CAM 124 for eight 0 10V DC inputs and four 10V outputs
C-DIAS Analogue Conversion Module CAM 124 for eight 0 10V DC inputs and four 10V outputs This analogue conversion module is a combination of analogue inputs and outputs. There are eight analogue inputs
C-DIAS Analogue Output Module CAO 081 for eight 10V DC outputs
C-DIAS Analogue Output Module CAO 081 for eight 10V DC outputs This analogue output module is used for driving components capable of being analogue driven (e.g. proportional pressure valves, frequency
C-DIAS Temperature sensing module CAI x temp. inputs C 8 x digital outputs +24V
C-DIAS Temperature sensing module CAI 887 8 x temp. inputs 0 600 C 8 x digital outputs +24V This analogue input module is used for the detection of temperatures in the range of 0 600 C by means of a NiCrNi
C-DIAS Analog Module CAO 086 For eight ±10 V Outputs
C-DIAS-ANALOG OUTPUT MODULE CAO 086 C-DIAS Analog Module CAO 086 For eight ±10 V Outputs This analog output module can be used to control analog controllable components (i.e.: proportional pressure vent,
C-DIAS Analogue Conversion Module CAM 011 for 3 x 0-10V DC inputs 2 x PT100 inputs and 1 x ±10V output
C-DIAS Analogue Conversion Module CAM 011 for 3 x 0-10V DC inputs 2 x PT100 inputs and 1 x ±10V output This analogue conversion module is a combination of analogue inputs and outputs. There are three analogue
C-DIAS Analog Input Module CAI 086 For eight, ±10V voltage inputs
C-DIAS ANALOG INPUT MODULE CAI 086 C-DIAS Analog Input Module CAI 086 For eight, ±10V voltage inputs This analog input module is used for the input of voltage values in the range of ±100mV / ±1.0V and10v.
HZS Solar Module
HZS 537-1 Solar Module Date of creation: 10.03.2015 Version date: 22.11.2017 Article number: 06-895-537-1E Publisher: SIGMATEK GmbH & Co KG A-5112 Lamprechtshausen Tel.: 06274/4321 Fax : 06274/4321-18
C-DIAS Analogue Output Module CAO 082 for eight ±10V DC respectively eight 0 20mA DC outputs
C-DIAS Analogue Output Module CAO 082 for eight ±10V DC respectively eight 0 20mA DC outputs This analogue output module is used for driving components capable of being analogue driven (e.g. proportional
C-DIAS Serial Interface CSI 021
C-DIAS SERIAL INTERFACE CSI 021 C-DIAS Serial Interface CSI 021 The CSI 021 makes it possible to communicate via 2 independent UART's. 2 x RS232/485/422 outputs are available. These outputs are switchable
C-DIAS Digital Input Module CDI 161 with 16 inputs
C-DIAS Digital Input Module CDI 161 with 16 inputs The CDI 161 is equipped with 16 inputs and one +24V level for reading the signal states "0" and "1". Appropriate input filters are available to suppress
Expansion Module HZS 541-1S
Expansion Module HZS 541-1S 12.10.2015 Page 1 System Description The external HZS 541-1S expansion module provides users of biomass heating systems with additional 230 V AC relay outputs, analog inputs
VARAN Manager PCI Insert module PCV 521 Versatile Automation Random Access Network
PCI INSERT MODULE PCV 521 VARAN Manager PCI Insert module PCV 521 Versatile Automation Random Access Network The PCI insert module, PCV 521, can be used in any standard PC. A VARAN Manager is available
Internal Buffer/Boiler Module HZS 534
INTERNAL BUFFER/BOILER MODULE HZS 534 Internal Buffer/Boiler Module HZS 534 30.11.2015 Page 1 INTERNAL BUFFER-/BOILERMODUL HZS 534 Configuration HZS 534 internal buffer/boiler module for the heating controller
HZS Internal Controller Expansion
HZS 532-2 Internal Controller Expansion Date of creation: 19.05.2016 Version date: 19.05.2016 Article number: 05-895-532-2E Publisher: SIGMATEK GmbH & Co KG A-5112 Lamprechtshausen Tel.: 06274/4321 Fax:
VARAN Digital Combined Module VDM 086
VARAN DIGITAL COMBINATION MODULE VDM 086 VARAN Digital Combined Module VDM 086 The VARAN VDM 086 module has eight +24 V / 2 A digital outputs (positive switching). The outputs are short circuit protected
Auxiliary Board MP-Bus HZS 562
MP BUS AUXILIARY BOARD HZS 562 Auxiliary Board MP-Bus HZS 562 The MP bus interface electronics connect a CAN bus system with an MP bus system. The electronics are used as an MP bus master to control MP
AI 046 S-DIAS Analog Input Module
AI 046 S-DIAS Analog Input Module Date of creation: 14.06.2017 Version date: 14.02.2018 Article number: 20-009-046-E Publisher: SIGMATEK GmbH & Co KG A-5112 Lamprechtshausen Tel.: +43/6274/4321 Fax: +43/6274/4321-18
VARAN Bus Coupler Module VBC 021 For connecting two VARAN bus systems
VARAN BUS COUPLER MODULE VBC 021 VARAN Bus Coupler Module VBC 021 For connecting two VARAN bus systems VARAN 1: VARAN 2: 1 x VARAN In 2 x VARAN Out 1 x VARAN In 1 x VARAN Out 1 x ETHERNET Port VARAN transmits
DIAS Interface Module VARAN DIV 511
DIAS INTERFACE MODULE VARAN DIV 511 DIAS Interface Module VARAN DIV 511 1 x VARAN-In 1 x VARAN-Out (Optional Ethernet (VtE)) The DIAS DIV 511 interface module serves as the voltage supply and connection
AO 081 S-DIAS Analog Output Module
AO 081 S-DIAS Analog Output Module Date of creation: 05.08.2013 Version date: 18.10.2017 Article number: 20-010-081-E Publisher: SIGMATEK GmbH & Co KG A-5112 Lamprechtshausen Tel.: +43/6274/4321 Fax: +43/6274/4321-18
C-DIAS Profibus DP Slave module CPB 021
C-DIAS Profibus DP Slave module CPB 021 The C-DIAS Profibus DP slave module CPB 021 serves as an interface module between the C-DIAS control system and Profibus. This module supports a galvanically separated
C-DIAS EtherNet/IP Slave CIP 022
C-DIAS-ETHERNET/IP SLAVEMODUL CIP 022 C-DIAS EtherNet/IP Slave CIP 022 The C-DIAS EtherNet/IP CIP 022 slave module is an interface module between the C-DIAS control system and EtherNet/IP bus. Technical
ISE 021 S-DIAS Interface Module RS232 / RS485
ISE 021 S-DIAS Interface Module RS232 / RS485 Date of creation: 23.04.2014 Version date: 31.01.2018 Article number: 20-101-021-E Publisher: SIGMATEK GmbH & Co KG A-5112 Lamprechtshausen Tel.: +43/6274/4321
Keyboard Unit Sigmatek
KEYBOARD UNIT SIGMATEK Keyboard Unit Sigmatek 10.10.2005 Page 1 KEYBOARD UNIT SIGMATEK Technical Data Performance data Interfacing Control panel Signal generator Left or right: chip card reader Back panel:
TSY 041 Training System Extension Motion
TSY 041 Training System Extension Motion Date of creation: 02.11.2016 Version date: 02.11.2016 Article number: 12-100-041-E Publisher: SIGMATEK GmbH & Co KG A-5112 Lamprechtshausen Tel.: 06274/4321 Fax:
Protected VARAN Digital Mixed Module PVDM 086
PROTECTED VARAN DIGITAL MXED MODULE PVDM 086 Protected VARAN Digital Mixed Module PVDM 086 The PVDM 086 Protected VARAN Digital Mixed Module has eight +24 V/2 A digital outputs (positive switching) that
VARAN Splitter Module VSV 041
VARAN SPLITTER MODULE VSV 041 VARAN Splitter Module VSV 041 With its 4 VARAN Out ports, the VARAN VSV 041 splitter module allows a VARAN bus system to be configured in a tree structure. At the Ethernet
Profibus DP slave. dual ported RAM 2Kbyte. Maximum length for I/O data. Maximum length for output data. Status display
PROFIBUS DP SLAVE MODULE DPB 021 Profibus DP slave module DPB021 The DPB 021 DIAS module is an interface module between the Profibus and the DIAS bus. Via the DIAS bus the data at the dual port RAM can
TO 161 S-DIAS Digital Output Module
TO 161 S-DIAS Digital Output Module Date of creation: 30.07.2013 Version date: 20.09.2018 Article number: 20-007-161-E Publisher: SIGMATEK GmbH & Co KG A-5112 Lamprechtshausen Tel.: +43/6274/4321 Fax:
C-DIAS VARAN Control Module CIV x VARAN-In 1 x VARAN-Out (Optional Ethernet (VtE))
C-DIAS VARAN CONTROL MODULE CIV 512 C-DIAS VARAN Control Module CIV 512 1 x VARAN-In 1 x VARAN-Out (Optional Ethernet (VtE)) The C-DIAS CIV 512 module serves as the power supply and connection for decentralized
VARAN Splitter PROFINET VSP 044
VARAN SPLITTER PROFINET VSP 044 VARAN Splitter PROFINET VSP 044 With its 3 VARAN Out ports, the VARAN VSP 044 splitter module allows a VARAN bus system to be configured in a tree structure. The VARAN Out
DM 161 S-DIAS Digital Mixed Module
DM 161 S-DIAS Digital Mixed Module Date of creation: 27.02.2014 Version date: 18.10.2017 Article number: 20-008-161-E Publisher: SIGMATEK GmbH & Co KG A-5112 Lamprechtshausen Tel.: +43/6274/4321 Fax: +43/6274/4321-18
SI 021 S-DIAS SSI Interface Module
SI 021 S-DIAS SSI Interface Module Date of creation: 16.06.2014 Version date: 18.10.2017 Article number: 20-022-021-E Publisher: SIGMATEK GmbH & Co KG A-5112 Lamprechtshausen Tel.: +43/6274/4321 Fax: +43/6274/4321-18
VARAN Client Board VEB 011/012 Versatile Automation Random Access Network
VARAN Client Board VEB 011/012 Versatile Automation Random Access Network This client board provides a simple method of connecting any periphery modules to the VARAN bus. 10.08.2011 Page 1 Technical Data
VARAN-INTERFACE VAC 012
VARAN-INTERFACE VAC 012 This VARAN interface module is used for communication between a DIAS drive and a control over the VARAN bus. The VAC 012 is built into the DIAS-Drive and is also equipped with interface
VARAN Splitter Module VSV 043
VARAN SPLITTER MODULE VSV 043 VARAN Splitter Module VSV 043 With its 4 VARAN Out ports, the VARAN VSV 043 splitter module allows a VARAN bus system to be configured in a tree structure. The VARAN Out ports
AI-917-A0. Analogue Input Module (4x 0-20 ma)
General Specifications GS48D17A00-00E-N AI-917-A0 Analogue Input Module (4x 0-20 ma) GENERAL Figure 1 This module has four analogue inputs and four logic pulse outputs. AI-917-A0 Analogue Input Module
ICA 012 S-DIAS Interface Module CAN
ICA 012 S-DIAS Interface Module CAN Date of creation: 06.09.2016 Version date: 25.06.2018 Article number: 20-102-012-E Publisher: SIGMATEK GmbH & Co KG A-5112 Lamprechtshausen Tel.: +43/6274/4321 Fax:
6ES7212-1BD30-0XB0. permissible range, lower limit (DC) permissible range, upper limit (DC)
6ES7212-1BD30-0XB0 Page 1 Product data sheet 6ES7212-1BD30-0XB0 SIMATIC S7-1200, CPU 1212C, COMPACT CPU, AC/DC/RLY, ONBOARD I/O: 8 DI 24V DC; 6 DO RELAY 0,5A; 2 AI 0-10V DC, POWER SUPPLY: AC 85-264 V AC
ETT 352 Touch Operating Panel
ETT 352 Touch Operating Panel Date of creation: 11.08.2014 Version date: 03.03.2017 Article number: 07-230-352-1-E Publisher: SIGMATEK GmbH & Co KG A-5112 Lamprechtshausen Tel.: 06274/4321 Fax: 06274/4321-18
HZS 351 Room Touch Control Panel
HZS 351 Room Touch Control Panel Date of creation: 13.03.2014 Version date: 25.03.2016 Article number: 06-895-351-E Publisher: SIGMATEK GmbH & Co KG A-5112 Lamprechtshausen Tel.: 06274/4321 Fax: 06274/4321-18
Temperature module. 4 inputs for thermocouples
2 Bosch Rexroth AG Electric Drives and Controls Documentation 4 inputs, M12 Thermocouples (TC) M12 Technical data S67-AI4-UTH-M12 Local bus interface Designation System bus M12 connector, B-coded, 5-pin,
VARAN Splitter PROFINET VSP 042
VARAN SPLITTER PROFINET VSP 042 VARAN Splitter PROFINET VSP 042 With its 3 VARAN Out ports, the VARAN VSP 042 splitter module allows a VARAN bus system to be configured in a tree structure. At the Ethernet
Processor module DCP 642
Processor module DCP 642 The DCP 642 processor module executes the control program and constitutes a major part of the automation system. Since it has no internal power supply, the processor module has
General information Engineering with Programming package. Display with display. Supply voltage 24 V DC Yes. Input current
Datasheet SIMATIC S7-1200, CPU 1214C, COMPACT CPU, DC/DC/DC, ONBOARD I/O: 14 DI 24V DC; 10 DO 24 V DC; 2 AI 0-10V DC, POWER SUPPLY: DC 20.4-28.8 V DC, PROGRAM/DATA MEMORY: 75 KB General information Engineering
C-IPC Expansion VM 052 (C-IPC VARAN Manager 052) Versatile Automation Random Access Network
C-IPC EXPANSION VM 052 C-IPC Expansion VM 052 (C-IPC VARAN Manager 052) Versatile Automation Random Access Network 3 x VARAN OUT With this expansion card, the C-IPC can be expanded with a VARAN Manager
Display. Supply voltage. Input current. Encoder supply. Output current. Power losses. Memory
Datasheet SIMATIC S7-1200, CPU 1214C, COMPACT CPU, AC/DC/RLY, ONBOARD I/O: 14 DI 24V DC; 10 DO RELAY 2A; 2 AI 0-10V DC, POWER SUPPLY: AC 85-264 V AC AT 47-63 HZ, PROGRAM/DATA MEMORY: 75 KB Display with
Display. Supply voltage. Input current. Encoder supply. Output current. Power losses. Memory
Datasheet SIMATIC S7-1200, CPU 1214C, COMPACT CPU, DC/DC/DC, ONBOARD I/O: 14 DI 24V DC; 10 DO 24 V DC; 2 AI 0-10V DC, POWER SUPPLY: DC 20.4-28.8 V DC, PROGRAM/DATA MEMORY: 75 KB Display with display Supply
RO 051 S-DIAS Relay Output Module
RO 051 S-DIAS Relay Output Module Date of creation: 10.08.2015 Version date: 18.10.2017 Article number: 20-064-051-E Publisher: SIGMATEK GmbH & Co KG A-5112 Lamprechtshausen Tel.: +43/6274/4321 Fax: +43/6274/4321-18
General information. Display. Supply voltage. Input current
Datasheet SIMATIC S7-1200, CPU 1212C, COMPACT CPU, DC/DC/DC, ONBOARD I/O: 8 DI 24V DC; 6 DO 24 V DC; 2 AI 0-10V DC, POWER SUPPLY: DC 20.4-28.8 V DC, PROGRAM/DATA MEMORY: 50 KB General information Engineering
General information Engineering with Programming package. Display with display. Supply voltage 24 V DC Yes
Datasheet SIMATIC S7-1200, CPU 1215C, COMPACT CPU, DC/DC/DC, 2 PROFINET PORT, ONBOARD I/O: 14 DI 24V DC; 10 DO 24V DC 0.5A 2 AI 0-10V DC, 2 AO 0-20MA DC, POWER SUPPLY: DC 20.4-28.8 V DC, PROGRAM/DATA MEMORY:
General information. Display. Supply voltage. Input current. Encoder supply. Output current
Data sheet SIMATIC S7-1200, CPU 1215C, COMPACT CPU, DC/DC/DC, 2 PROFINET PORT, ONBOARD I/O: 14 DI 24V DC; 10 DO 24V DC 0.5A 2 AI 0-10V DC, 2 AO 0-20MA DC, POWER SUPPLY: DC 20.4-28.8 V DC, PROGRAM/DATA
General information. Display. Supply voltage. Input current. Encoder supply. Output current
Data sheet *** SPARE PART*** SIMATIC S7-1200, CPU 1214C, COMPACT CPU, DC/DC/DC, ONBOARD I/O: 14 DI 24V DC; 10 DO 24 V DC; 2 AI 0-10V DC, POWER SUPPLY: DC 20.4-28.8 V DC, PROGRAM/DATA MEMORY: 50 KB General
General information Engineering with Programming package. Display with display. Supply voltage 24 V DC Yes. Input current
Datasheet SIPLUS S7-1200 CPU 1214C DC/DC/DC -40... +70 DEGREES C WITH CONFORMAL COATING BASED ON 6ES7214-1AG31-0XB0. COMPACT CPU, DC/DC/DC, ONBOARD I/O: 14 DI 24V DC; 10 DO 24 V DC; 2 AI 0-10V DC, POWER
Submittal Data Sheet WAGO Node for itm
The WAGO Node integrates ancillary equipment into the Intelligent Touch Manager (itm) DCM601A71 with the use of DI, DO, AI and AO signals. It provides monitoring and control of non-daikin equipment via
General information Engineering with Programming package. Display with display
Datasheet SIPLUS S7-1200 CPU 1212C AC/DC/RLY -40... +70 DEGREES C WITH CONFORMAL COATING BASED ON 6ES7212-1BE31-0XB0. COMPACT CPU, AC/DC/RELAY, ONBOARD I/O: 8 DI 24V DC 6 DO RELAY 2A 2 AI 0-10V DC, POWER
Cube67 - Modular I/O station
Compact modules Cube67 DI16 C 8xM12 Cube67 DI8 C 4xM12 Cube67 DI8 C 8xM8 Digital inputs Art.-No. UL 56602 UL 56612 UL 56622 approx. 50 ma approx. ma Terminator integrated Configuration PIN 2 input/diagnostic
Temperature module. 4 inputs for resistance thermometers
2 Bosch Rexroth AG Electric Drives and Controls Documentation 4 inputs, M12 Resistance thermometer, resistors, potentiometer Technical data S67-AI4-RTD-M12 Local bus interface Designation System bus M12
General information. Display. Supply voltage. Input current. Encoder supply. Output current
Data sheet SIMATIC S7-1200, CPU 1215C, COMPACT CPU, DC/DC/DC, 2 PROFINET PORT, ONBOARD I/O: 14 DI 24V DC; 10 DO 24V DC 0.5A 2 AI 0-10V DC, 2 AO 0-20MA DC, POWER SUPPLY: DC 20.4-28.8 V DC, PROGRAM/DATA
Temperature modules. 8 inputs for connection of thermocouple sensors S20-AI-8-UTH
8 inputs for connection of thermocouple sensors 2 Bosch Rexroth AG Electric Drives and Controls 8 inputs for thermocouples Linear voltages from -100 mv to +100 mv 1 input -5 V to +5 V 4 Pt 100 inputs (external
to 12a Added Standard and Electrical requirements for UL table 1.1
Document changes and version status C-DIAS SAFETY DIGITAL INPUT MODULE CSDI 162 Change date Affected page(s) Changes/expansions/corrections Version 19.12.2013 12 to 12a Added Standard and Electrical requirements
HZS 352 Touch Room Unit
HZS 352 Touch Room Unit Date of creation: 25.04.2014 Version date: 25.03.2016 Article number: 06-895-352-E Publisher: SIGMATEK GmbH & Co KG A-5112 Lamprechtshausen Tel.: 06274/4321 Fax: 06274/4321-18 Email:
KL 181 S-DIAS +24 V Potential Distributor Module
KL 181 S-DIAS +24 V Potential Distributor Module Date of creation: 30.07.2013 Version date: 18.10.2017 Article number: 20-024-181-E Publisher: SIGMATEK GmbH & Co KG A-5112 Lamprechtshausen Tel.: +43/6274/4321
General information. Display. Supply voltage. Input current. Encoder supply. Output current
Data sheet SIMATIC S7-1200, CPU 1214C, COMPACT CPU, DC/DC/RELAY, ONBOARD I/O: 14 DI 24V DC; 10 DO RELAY 2A; 2 AI 0-10V DC, POWER SUPPLY: DC 20.4-28.8 V DC, PROGRAM/DATA MEMORY: 75 KB General information
Technology modules. 1 SSI interface for absolute encoders, 1 analog output S20-SSI-AO-1/1
1 SSI interface for absolute encoders, 1 analog output S20- 2 Bosch Rexroth AG Electric Drives and Controls Position detection via absolute encoders with SSI interface Encoder resolution up to 56 bit Transmission
General information. Display. Supply voltage. Input current. Encoder supply. Output current
Data sheet SIMATIC S7-1200, CPU 1214C, COMPACT CPU, DC/DC/DC, ONBOARD I/O: 14 DI 24V DC; 10 DO 24 V DC; 2 AI 0-10V DC, POWER SUPPLY: DC 20.4-28.8 V DC, PROGRAM/DATA MEMORY: 75 KB General information Engineering
STBEHC3020KC counter kit STB - 1 CH Hz - 2 I
Characteristics counter kit STB - 1 CH - 0..40000 Hz - 2 I Main Range of product Product or component type Number of channels 1 Complementary Kit composition Counting input number 2 Counting frequency
PX165. DMX Splitter INSTRUCTION MANUAL
PX165 DMX Splitter INSTRUCTION MANUAL R CONTENTS 1. General description... 3 2. Safety conditions... 3 3. DMX signal connection... 4 3.1. Exemplary DMX lines... 4 3.2. The terminator... 6 3.3. Rules for
TM3TI4 module TM3-4 inputs temperature
Characteristics module TM3-4 inputs temperature Main Range of product Product or component type Range compatibility Analogue input number 4 Analogue input type Complementary Analogue input resolution Permissible
GSV-1A4 M12/2 M12/2. Highlights
GSV-1A4 M12/2 M12/2 Highlights Input sensitivity: 2mV/V; 4mV/V, 2 mv/v, 1mV/V, 0.5mV/V configurable via jumpers Output signals ±10V AND 12mA+-8mA on 15 pin Sub-D Integrated half and quarter bridge completion
PCD3.C90. Date Modification Asked by: Version E/A Bus Connector PCD2.K106 change to PCD3.K106 Müller.R 1.1
Manual PCD3.C90 Revision History Date Modification Asked by: Version 14.09.09 E/A Bus Connector PCD2.K106 change to PCD3.K106 Müller.R 1.1 22.09.09 Added E/A Bus Connector PCD3.K116 Müller.R 1.2 06.01.10
ETT 312 Build-In Touch Terminal
ETT 312 Build-In Touch Terminal Date of creation: 01.02.2016 Version date: 23.01.2017 Article number: 01-230-312-E Publisher: SIGMATEK GmbH & Co KG A-5112 Lamprechtshausen Tel.: 06274/4321 Fax: 06274/4321-18
BMXAMI0410 analog input module M340-4 inputs - high speed
Characteristics analog input module M340-4 inputs - high speed Main Range of product Product or component type Electrical connection Isolation between channels Input level Analogue input number 4 Analogue
Measuring transducers MI4x0 series Programmable transducers for RTD sensors MI450
Measuring transducers MI4x0 series Programmable transducers for RTD sensors MI450 o Measuring of resistance of RTD sensors (Pt100, Pt1000, Ni100, Cu10,...) o Accuracy class up to: 0.5 o Programmable input
LAUREL. Laureate RTD Temperature Panel Meter / Controller ELECTRONICS, INC. Features. Description. Specifications
LAUREL ELECTRONICS, INC. Laureate RTD Temperature Panel Meter / Controller Features Factory calibrated for 100Ω platinum, 10Ω copper & 120Ω nickel RTDs 2, 3 or 4-wire connection with lead resistance compensation
TM3TM3 module TM3-2 temperature inputs and 1 analog output
Characteristics module TM3-2 temperature inputs and 1 analog output Main Range of product Product or component type Range compatibility Analogue input number 2 Analogue input type Analogue output number
General information. Display. Supply voltage. Input current. Encoder supply. Power losses
Data sheet SIMATIC S7-1200, CPU 1215C, COMPACT CPU, DC/DC/RELAY, 2 PROFINET PORT, ONBOARD I/O: 14 DI 24V DC; 10 DO RELAY 2A, 2 AI 0-10V DC, 2 AO 0-20MA DC, POWER SUPPLY: DC 20.4-28.8 V DC, PROGRAM/DATA
Thermocouple Input Module Product Specifications and Installation Data
Thermocouple Input Module Product Specifications and Installation Data 1 DESCRIPTION The Horner APG Thermocouple Input Modules allow thermocouple temperature sensors to be directly connected to the PLC
General information. Display. Supply voltage. Input current. Encoder supply. Output current
Data sheet SIMATIC S7-1200, CPU 1211C, COMPACT CPU, AC/DC/RELAY, ONBOARD I/O: 6 DI 24V DC; 4 DO RELAY 2A; 2 AI 0-10V DC, POWER SUPPLY: AC 85-264 V AC AT 47-63 HZ, PROGRAM/DATA MEMORY: 50 KB General information
Analog input module. 4 inputs, voltage and current
2 Bosch Rexroth AG Electric Drives and Controls Documentation 4 inputs: M12, 0 to 20 ma, 4 to 20 ma, ±20 ma, 0 to 10 V, ±10 V Technical data S67-AI4-U/I-M12 Local bus interface Designation System bus M12
TM3AI4 module TM3-4 analog inputs
Characteristics module TM3-4 analog inputs Main Range of product Product or component type Range compatibility Analogue input number 4 Analogue input type Complementary Analogue input resolution Permissible
General information. Display. Supply voltage. Input current
Data sheet SIMATIC S7-1200, CPU 1215C, COMPACT CPU, DC/DC/DC, 2 PROFINET PORT, ONBOARD I/O: 14 DI 24V DC; 10 DO 24V DC 0.5A 2 AI 0-10V DC, 2 AO 0-20MA DC, POWER SUPPLY: DC 20.4-28.8 V DC, PROGRAM/DATA
General information. Display. Supply voltage. Input current. Encoder supply. Output current
Data sheet SIMATIC S7-1200, CPU 1211C, COMPACT CPU, DC/DC/RELAY, ONBOARD I/O: 6 DI 24V DC; 4 DO RELAY 2A; 2 AI 0-10V DC, POWER SUPPLY: DC 20.4-28.8 V DC, PROGRAM/DATA MEMORY: 50 KB General information
Inclination sensors 2-dimensional, measuring range up to ±90
Features Size 52 mm MEMS capacitive measuring principle EN13849 compliant firmware E1 compliant design Interface CANopen, SAE J1939, Analog Connection M12 and cable Protection up to IP 69K Optional GIM500R
General information. Display. Supply voltage. Input current. Encoder supply. Output current
Data sheet SIMATIC S7-1200, CPU 1211C, COMPACT CPU, DC/DC/RELAY, ONBOARD I/O: 6 DI 24V DC; 4 DO RELAY 2A; 2 AI 0-10V DC, POWER SUPPLY: DC 20.4-28.8 V DC, PROGRAM/DATA MEMORY: 50 KB General information
General information. Display. Supply voltage. Input current
Data sheet SIMATIC S7-1200F, CPU 1214 FC, COMPACT CPU, DC/DC/DC, ONBOARD I/O: 14 DI 24V DC; 10 DO 24 V DC; 2 AI 0-10V DC, POWER SUPPLY: DC 20.4-28.8 V DC, PROGRAM/DATA MEMORY 125 KB General information
Added Standard and Electrical requirements for UL table Switching-off inductive loads 1.2
C-DIAS SAFETY CPU CSCP 012 Document changes and version status Change date Affected page(s) Changes/expansions/corrections Version 19.12.2013 14 Added Standard and Electrical requirements for UL table
General information. Display. Supply voltage
Data sheet SIMATIC S7-1200, CPU 1211C, COMPACT CPU, DC/DC/RELAY, ONBOARD I/O: 6 DI 24V DC; 4 DO RELAY 2A; 2 AI 0-10V DC, POWER SUPPLY: DC 20.4-28.8 V DC, PROGRAM/DATA MEMORY: 50 KB General information
General information. Display. Supply voltage. Input current
Data sheet SIMATIC S7-1200, CPU 1217C, COMPACT CPU, DC/DC/DC, 2 PROFINET PORT ONBOARD I/O: 10 DI 24V DC; 4 DI RS422/485; 6 DO 24V DC; 0,5A; 4 DO RS422/485; 2 AI 0-10V DC, 2 AQ 0-20MA; POWER SUPPLY: DC
General information. Display. Supply voltage. Input current
Data sheet SIMATIC S7-1200, CPU 1214C, COMPACT CPU, DC/DC/DC, ONBOARD I/O: 14 DI 24V DC; 10 DO 24 V DC; 2 AI 0-10V DC, POWER SUPPLY: DC 20.4-28.8 V DC, PROGRAM/DATA MEMORY: 100 KB General information Firmware
General information. Display. Supply voltage
Data sheet SIMATIC S7-1200, CPU 1211C, COMPACT CPU, DC/DC/DC, ONBOARD I/O: 6 DI 24V DC; 4 DO 24 V DC; 2 AI 0-10V DC, POWER SUPPLY: DC 20.4-28.8 V DC, PROGRAM/DATA MEMORY: 50 KB General information Product
Inclination sensors 1-dimensional, measuring range
Features Size 52 mm MEMS capacitive measuring principle EN13849 compliant firmware E1 compliant design Interface CANopen, SAE J1939, Analog Connection M12 and cable Protection up to IP 69K Optional GIM500R
General information. Display. Supply voltage. Input current
Data sheet SIMATIC S7-1200F, CPU 1215 FC, COMPACT CPU, DC/DC/DC, 2 PROFINET PORT, ONBOARD I/O: 14 DI 24VDC; 10 DO 24V DC 0.5A; 2 AI 0-10V DC, 2 AO 0-20MA DC, POWER SUPPLY: DC 20.4-28.8 V DC, PROGRAM/DATA
Analog Input Modules. 4 Inputs
Bosch Rexroth AG Electric Drives and Controls Documentation Instructions Technical data S67-AI4-U/I-M12 Analog inputs Number 4 Conversion time of A/D converter analog input module for current- and voltage
TM3TI8T module TM3-8 inputs temperature
Characteristics module TM3-8 inputs temperature Main Range of product Product or component type Range compatibility Analogue input number 8 Analogue input type Complementary Analogue input resolution Input
General information. Engineering with. Supply voltage. Load voltage L+ Input current. Power losses. Memory. Work memory.
Product data sheet SIMATIC S7-300, CPU 314C-2DP COMPACT CPU WITH MPI, 24 DI/16 DO, 4AI, 2AO, 1 PT100, 4 FAST COUNTERS (60 KHZ), INTEGRATED DP INTERFACE, INTEGRATED 24V DC POWER SUPPLY, 64 KBYTE WORKING
Room sensors QFA4160 QFA41 D AQF4150 AQF3153. Symaro. for relative humidity and temperature with calibration certificates
1 859 1859P01 1859P02 1859P04 QFA4160 QFA41 D AQF4150 AQF3153 Symaro Room sensors for relative humidity and temperature with calibration certificates QFA41 Operating voltage AC 24 V / DC 13.5...3 Signal
Analog Output Module. ST-4xxx. User Manual CREVIS Co.,Ltd. Version FnIO S-Series
1 FnIO S-Series Analog Output Module ST-4xxx User Manual Version 1.01 2012 CREVIS Co.,Ltd 2 FnIO S-Series DOCUMENT CHANGE SUMMARY REV PAGE REMARKS DATE EDITOR 1.0 New Document 2011/10/07 JE KANG 1.01 5
General information. Display. Supply voltage
Data sheet SIMATIC S7-1200, CPU 1212C, COMPACT CPU, DC/DC/RLY, ONBOARD I/O: 8 DI 24V DC; 6 DO RELAY 2A; 2 AI 0-10V DC, POWER SUPPLY: DC 20.4-28.8 V DC, PROGRAM/DATA MEMORY: 75 KB General information Product