ENERGY MANAGEMENT Table of Contents

Size: px
Start display at page:

Download "ENERGY MANAGEMENT Table of Contents"

Transcription

1 ENERGY MANAGEMENT Table of Contents System components Maximum demand optimization (demand control) Mains monitoring Cost allocation / Cost center acquisition Power factor relay with bus interface Software

2 146 Product Catalogue EM

3 System components System components Central unit Page Gateway Page System timer Page Communication processor Page Repeater Page Switching module Page Modbus coupler Page Ethernet Interfaces-COM-Server Page M-Bus Level converter Page EIB Network coupler Page Product Catalogue EM 147

4 148 Product Catalogue EM

5 System components Central unit EMIS 1500 Central Unit A network-compatible central unit for data acquisition and organization for the Energy Management instruments connected to it. Description Intensive ongoing development of the proven FRAKO Energy Management System has resulted in the EMIS 1500 Central Unit, representing state-of-the-art data collector technology. In addition to the widespread Ethernet technology with TCP/IP, the Linux operating system is used within EMIS The Energy Management instruments are connected via the FRAKO Bus to the EMIS 1500 Central Unit, but can also be connected through one or more EMG 1500-PN. Several PCs can be connected online to the EMIS 1500 simultaneously. The data are acquired and saved by the following instruments: Maximum Controller EM-MC 2200 Maximum-Optimization EML 1101 Power Quality Analyzer EM-PQ 2300 Mains Monitoring EMA 1101 Mains Monitoring EM-PQ 1500 Cost center- and alarm system EMF 1102 Power Factor Control Relay EMR 1100 MOD-Bus devices via coupler or MOD-Bus TCP M-Bus devices via separate coupler JM measured variables PL-Sensor The sophisticated alarm functions enable: All logged-in metering and analogue channels to be provided with lower and upper alarm limits Individual alarms or groups of alarms to be linked to the following signalling methods: - contacts on the EMIS 1500 Central Unit or the EMD 1101 Add-on Unit, - network printer, - text messaging (SMS), - telefax, - messages and - alarm reports Energy Management instruments can be linked in two ways: via the Ethernetstandard (TCP/IP) to a gateway with FRAKO Starkstrombus interface or via integrated FRAKO Starkstrombus interface Various means of connection exist to access the Central Unit from a PC: Connection via Ethernet (TCP/IP-Protocol) A dial-up network connection to be made via modem direct serial connection by dial-up network The Linux operating system installed internally enables an online connection to be made simultaneously from several PCs to the Central Units. Configuration of the EMIS 1500 Central Unit is carried out with the FRAKO-NET software package (included in scope of supply). Product Catalogue EM 149

6 A certain number of system points are required for each Energy Management instrument. The instruments can be combined as desired, provided that the maximum number of system points is not exceeded. Technical data Power supply Supply voltage 230 VAC +/- 10 % or (switchable): 110 VAC +/- 10 % Frequency 45 up to 65 Hz Power consumption max. 50 VA Interfaces 1 Ethernet RJ45, connection of LAN Network Protocol: TCP/IP Transmission: 100BaseTx full duplex 2 Serial interfaces 9 pole Sub-D-bush (male),rs232 for by dial-up or direct connection high transmission rate: up to Baud Connection to FRAKO Starkstrombus Display-/Operating elements Outputs 3 Alarm signalling contacts electrical connection: according norm EIA RS 485 high transmission rate: 76.8 kbit/sec Protocol: FRAKO Starkstrombus 3 LEDs, 4 operating buttons, bright LC-Display potential-free normal open contact,free programable contamination: max.48 V AC/DC, max.1 A Mechanical construction Dimensions 300x75x220 mm (WxHxD) Ingress protection Housing IP40, Terminals IP20 Housing material metal housing Orientation standing / vertical Weight 3,40 kg Operating conditions Ambient 0 up to +50 C temperature PC-requirements for the software package FRAKO-Net Hardware Pentium min. 2 GHz clock frequency working memory min. 1 GB RAM free hard disk capacity 6 GB Ethernet 10/100 MB network connection or/and one free serial interface CD-ROM-drive SVGA-Graphic card colour screen with minimum resolution of 1024 x 768 Software Windows 2000 pro SP3 Windows XP pro SP3 Windows 2003 Server Internet Explorer 5.5 Versions Type Number of system Article-No. points EMIS 1500 S EMIS 1500 M EMIS 1500 L EMIS 1500 XL EMIS 1500 XXL Optional accessory Type Description Article-No. EMIS " rack mounting kit height 2U for installing an EMIS 1500 in a 19" rack, consisting of mounting frame, cage nuts and retaining screws EMIS 1500 software upgrade (S to M) EMIS 1500 software upgrade (M to L) EMIS 1500 software upgrade (L to XL) EMIS 1500 software upgrade (XL toxxl) Flash Card System points- Extension package EMIS 1500 EM-PC modem Upgrade of an EMIS 1500 S Central Unit (50 system points) to an EMIS 1500 M (100 system points) Upgrade of an EMIS 1500 M Central Unit (100 system points) to an EMIS 1500 L (200 system points) Upgrade of an EMIS 1500 L Central Unit (200 system points) to an EMIS 1500 XL (350 system points) Upgrade of an EMIS 1500 XL Central Unit (350 system points) to an EMIS 1500 XXL (550 system points) 256 MB flash card, industrial standard prepared for the EMIS 1500 expansion of central unit EMIS 1500 (50 system points) Telephone modem for long-distance data transfer (serial interface) between PC and EMIS 1500, EML or EMP. Connected to the telephone network by an analogue connection Product Catalogue EM

7 Dimensions Product Catalogue EM 151

8 152 Product Catalogue EM

9 System components Gateway EMG 1500-PN Gateway The gateway EMG 1500-PN is the interface between ethernet and the FRAKO Starkstrombus. Description It is possible to install a maximum of eight Gateways per EMIS 1500 in the Ethernet system. Gateways can also be linked up via a company s internal network. Other standard bus systems such as Modbus can also be connected. The Gateway has three ports: Network connection via Ethernet standard (TCP/IP) Interfaces to the FRAKO Starkstrombus Interfaces for device configuration Product Catalogue EM 153

10 Technical data Power supply Mains voltage 230 VAC +/- 10 % Frequency 45 up to 65 Hz Power consumption approx. 10 VA Fuse protection max. 2 A external required Interfaces 1 Ethernet RJ45, to connection on LAN Network Protocol: TCP/IP Transmission: 10BaseT half duplex 1 FRAKO Starkstrombus for connection to FRAKO Energy Management System, according to EN 50170(P-Net) standardised fieldbus, RS 485 Transfer speed: 76,8 kbit/s 1 Serial interface 9 pole Sub-D-bush (female), RS 232 V.24, to device configuration Protocol: FRAKO internally High transmission rate: Baud, 8 Bit, 1 Stopbit,no equality Display elements 4 light-emitting diodes Connections screw terminals wire cross-section: max. 2,5 mm² Mechanical construction Dimensions 140x90x59 mm (WxHxD), DIN module case 8 TE Ingress protection Housing/terminals IP40/20 Version Protection class II at VDE 0411 / DIN EN Housing flame-retardant UL94-V0 Installation on standard rail 35 mm according to DIN EN Mounting position optional Weight approx. 0,5 kg Operating conditions Ambient 0 up to +50 C temperature Dimensions Article-No Product Catalogue EM

11 System components System timer EMT 1101 System timer A clock module for the timed switching of up to 250 switching or parameter channels. Description Channels in the EM-MC 2200 Maximum Controller or the EML 1101 Maximum Demand Controller with its EMD 1101 Add-on Units can be used as switching channels, as can also Add-on Units that are directly connected to the FRAKO Bus. The status of every switching channel can be changed regardless of the control status of the EM-MC 2200 or EML In addition, time-dependent parameters such as alarm limits or set points in the devices of the FRAKO Energy Management System can be changed by this module. Communication is via the FRAKO Bus. Module for time control Time-dependent switching via volt-free contacts of loads such as compressors, HVAC systems, etc. to reduce energy costs Centralized control of loads, making local timers unnecessary. This means that switching times can be easily and quickly changed at the PC, for example when working hours vary Time-dependent control of circulating pumps to reduce heating energy costs Automatic ventilation of rooms and buildings Switching of solenoid valves in compressed air networks to reduce leakage losses Time-dependent changes to alarm limits to identify system leaks at night or at the weekend Up to 100 switching channels can be combined into several switching groups 300 switching operations 150 daily programs Weekly program Exceptions table (caters for up to 365 exceptional days, such as puplic holidays) Product Catalogue EM 155

12 Technical data Power supply Mains voltage 230 VAC +/-10 % Frequency 45 up to 65 Hz Power consumption approx. 5 VA Fuse protection max. 2 A external required Interfaces Serial A 25 pole Sub-D-bush (female), for connection of EM-DCF77 radio clock Serial B 9 pole Sub-D-bush (female), RS 232, for connection of a PC FRAKO Starkstrombus Display elements Connections For connection to FRAKO Energy Management System, according to EN 50170(P-Net) standardized fieldbus, RS 485 High transmission rate: 76,8 kbit/s 3 light emitting diodes in housing with screw terminals conductor cross-section: max. 2,5 mm² Mechanical construction Dimensions 158x75x120 mm (WxHxD) Ingress protection IP40 Version according to VDE 0411 protection class I (also DIN EN ) Housing material PC with 10% GF, V-0 flame-retardant UL-94 V-0 Installation screw mounting or standart rail 35 mm according to DIN EN Mounting position optional Weight approx. 0,8 kg Operating conditions Ambient 0 up to +40 C temperature PC-requirements for the software package EMT-SW Hardware Pentium min. 1 GHz clock frequency working memory min. 512 MB RAM free hard disk capacity 10 MB Ethernet 10/100 MB network connection or/and one free serial interface CD-ROM, SVGA-Graphic card colour screen with minimum resolution of 1024 x 768 Software Windows 2000 pro SP3 XP pro SP Server, IE5 Dimensions Article-No Product Catalogue EM

13 System components Communications processor EMP 1100 Communications processor Microprocessor-controlled interface module for data interchange between the FRAKO Bus and PLCs, PCs, centralized instrumentation and control systems, and building automation or similar systems.. Description Data from any instrument of the FRAKO Energy Management System can be transmitted to external systems Serial interface A (standardized): 3964R framework protocol, RK512 interpreter Serial interface B: access via PC Programming and parameterizing software included in scope of supply Three LEDs indicate operation, access to the FRAKO Starkstrombus and access to one of the serial interfaces Current data from up to 100 instruments of any type in the FRAKO Energy Management System are saved in a maximum of 100 data blocks. The cycle time for data polling is adjustable. Product Catalogue EM 157

14 Technical data Power supply Mains voltage 230 VAC +/-10 % Frequency 50 up to 60 Hz Power consumption max. 3 VA Fuse protection max. 2 A external required Outputs Serial interface A 25 pole Sub-D-bush (female), RS 232, framework protocol 3964R, data protocol RK 512 Serial interface B 9 pole Sub-D-bush (female), RS 232, for a connection of a PC FRAKO Starkstrombus for connection to FRAKO Energy Management System, according to EN 50170(P-Net) standardised fieldbus, RS 485 Transfer speed: 76,8 kbit/s 3 light emitting diode in cases via connector strip Display elements Connections Mechanical construction Dimensions 158x75x120 mm (WxHxD) Ingress protection IP50 Version Protection class I according to VDE 0411 / EN Housing flame-retardant UL94-V0 (according to the manufacturer) Installation screw mounting or standard rail 35 mm according to DIN EN Mounting position optional Weight approx. 0,8 kg Operating conditions Ambient 0 up to +40 C temperature PC-requirements for the software package Hardware Pentium mind. 1 GHz clock frequency working memory min. 512 MB RAM free hard disk capacity10 MB Ethernet 10/100 MB network connection or/and one free serial interface CD-ROM SVGA-Graphic card colour screen with minimum resolution of 1024x768 Software Windows 2000 pro (mind. SP3) Windows XP pro (mind. SP1) Windows 2003 Server (mind. SP1) Internet Explorer 5.5 Optional accessory Type Description Article-No. EM-PC-Modem Phone modem for data transmission (serial interface) between PC and EMIS 1500, EML and EMP. Connection to the phone network via analog connector Dimensions Article-No Product Catalogue EM

15 System components Repeater EMB 1101 Repeater The EMB 1101 repeater serves to condition and forward signals in the FRAKO Starkstrombussystem. Required if the length of the string exceeds 1000 m as well as if more than 32 devices may bei operated on one link of the bus system. Description Device for conditioning and forwarding of signals Up to 120 devices may be operated in the bus system Required if the length of the string exceeds 1000 m as well as if more than 32 devices may bei operated on one link of the bus system By assembling the repeater the safety of the bussystem will be increased particularly in difficult operating conditions with disturbance factors Star-shaped wiring. Up to 4 strings, each with up to 32 devices can be realized with a repeater By cascading repeaters bus lengths of up to 15 km can be implemented Existing cable connections, that use no FRAKO specified bus cable, can be used for distances up to 4 km Parts of the bus system can be electrically isolated by the repeater, to avoid pontential compensation currents über den FRAKO Starkstrombus zu vermeiden In case of an electrical error in a connected lines, the error will be automatically detected and displayed, and the corresponding line will be closed Data transmission errors are automatically detected and signalled by an LED Product Catalogue EM 159

16 Technical data Power supply Supply voltage Frequency Power consumption Fuse protection In- / Outputs Number Protocol 60V - 230V + 15% AC or DC if AC 48 up to 62 Hz approx. 6 VA max. 2 A external required 4 lines, therefrom 1 line galvanically separated FRAKO Starkstrombus, according to EN 50170(P-Net), standardised fieldbus, RS 485 transfer speed: 76,8 kbit/s Display elements Operating(Run) blinking green LED Data transfer per line one green and red LED Connections screw terminals wire cross-section: max. 2,5 mm² Mechanical construction Dimensions 140x90x59 mm (WxHxD), DIN module case 8 TE Ingress protection Housing IP40, Terminals IP20 Version according to VDE 0411 Protection class II (also DIN EN ) Housing material PC with 10% GF,V-0, flame-retardant UL-94 V-0 Installation on standard rail 35 mm according to DIN EN Mounting position optional Weight approx. 0,6 kg Operating conditions Ambient 0 up to +50 C temperature Dimensions Article-No Product Catalogue EM

17 System components Switching module EMD 1101 Switching module The Add-on Unit with 8 switching channels can be connected as desired to: EM-MC 2200 Maximum controller or EML 1101 Maximum Demand Controller EMT 1101 System Timer via the FRAKO Starkstrombus Description Display of switching status by LED LED annunciator for bus access Definition of the switching status (on/off) of the individual switching channels if a fault occurs Product Catalogue EM 161

18 Technical data Power supply Mains voltage 230 VAC -15 % up to +10 % Frequency 45 up to 65 Hz Power consumption 4 VA Fuse protection max. 2 A external required Outputs 8 Switching normal open contact 250 VAC / 4 A channels 1 Extension 2-Wire-fieldbus, RS 485 bus / FRAKO Starkstrombus Operating elements 8-fold DIP-switching series, 10-level rotary switch Display elements 9 light emitting diode Connections in cases via connector strip conductor cross-section: max. 2,5 mm² Mechanical construction Dimensions 158x75x120 mm (WxHxD) Ingress protection IP40 Version Protection class 2 according to DIN/ EN Housing flame-adversely UL94-V0 (according to the manufacturer) Installation screw mounting or on standard rail 35 mm according to DIN EN Mounting position wall mounting, vertical Weight approx. 0,8 kg Operating conditions Ambient 0 up to +45 C temperature Storage -20 up to +60 C temperature Article-No Dimensions 162 Product Catalogue EM

19 System components Modbus coupler Modbus coupler Modbus coupler The Modbus coupler allows to connect Modbus devices with the FRAKO Energy Management System. Data between the coupler and the Central Unit EMIS 1500 is exchanged via Ethernet. Description A maximum of 31 Modbus devices can be connected to the coupler. The configuration software and a wall wart are included with the delivery. Ready to use address tables already exist for the following Modbus devices: EMA 1296 Socomec DIRIS A20, A40 Janitza UMG 507 Schneider Masterpact Leistungsschalter FRAKO Active Filters Further Modbus address tables can be built and saved with the configuration software SYSTEM-SW In the SYSTEM-SW the Modbus coupler will be logged in as a bus coupler Product Catalogue EM 163

20 Technical data Power supply (MOD-Bus coupler) Input voltage 12V - 48V DC +/-10% 9V eff - 30V eff AC +/-10% Current consumption Typ. 85 ma at 24 V DC Power supply (wall wart) Input voltage 230 V AC Frequency 50 Hz Current consumption 65 ma Output voltage 18 V DC Output current 300 ma Interfaces 1 MOD-Bus RS485, 9 pole Sub-D-bush (male) Ethernet RJ45, connection of LAN Network Protocol: TCP/IP Transmission: 10 / 100 BT autosensing Mechanical construction Dimensions 22x75x105 mm (WxHxD) Installation on standard rail 35 mm according to DIN EN Weight approx. 0,2 kg Operating conditions Ambient temperature not assembled: 0 up to +60 C assembled: 0 up to +50 C Article-No Product Catalogue EM

21 System components Ethernet Interfaces-COM-Server Ethernet Interfaces EM-COM-Server Ethernet Interfaces-COM-Server Interface converter for rail mounting, enables access to the RS 232 interface of the maximum controller via Ethernet network (TCP/IP). A comfortable solution for serial interfaces: network via serial interface. Description The driver software and the wall wart required for the acces are part of the scope of delivery. You are allowed to install the driver software on several computers. As an RS232 interface is generally specified for data interchange over short distances, it becomes more complicated when longer lines are involved. In addition to widely used data interchange options such as modems or optical fibre converters, it is also possible to use the network cable Instruments that are not accessible via a fieldbus (2-wire) are linked to the system by means of the COM server if a network connection is available Instruments installed in other properties can be connected to the Energy Management System via the internal network Technical data Power supply (EM-COM-SERVER) Input voltage stab. 5 VDC Current consumption typ. 220 ma, max. 270 ma Power supply (wall wart) Input voltage 230 VAC Frequency 50 Hz Output voltage stab. 5 VDC, 1 A Interfaces 1 Seriell 9 pole Sub-D-bush (male), RS 232, for connection of EML,.. 1 Network 10 BaseT Mechanical construction Dimensions 22x75x105 mm (WxHxD) Installation on standard rail 35 mm according to DIN EN Weight approx. 0,2 kg Operating conditions Ambient 0 up to +60 C temperature Article-No Product Catalogue EM 165

22 166 Product Catalogue EM

23 System components M-Bus level converter EM-PW 3 / EM-PW 20 / EM-PW 20 TCP / EM-PW 100 TCP M-Bus level converter M-Bus level converter to connect M-Bus counters with the FRAKO Energy Informations System. Description The M-Bus (Meter-Bus) is a 2-wire fieldbus, developed to transmit energy consumption data. The market offers a wide spectrum of energy meters for a variety of media. With the M-bus level converter up to 3 (EM-PW3) resp. 20 (EM-PW20) M-Bus meters can be integrated in the FRAKO Energy Management System. In practice the consumption data from heat meters, water meters, electricity meters, gas meters etc. are readout via remote inquiry. The usual readout cycle is once a month. With the coupling of the M-Bus meter to the FRAKO Energy Information System, current measurement readings and 15 minute graphs can be shown. The particular M-Bus meter must allow those fast interrogation cycles The analysis of the recorded measurement data is done with the visualization software EMVIS 3000 or the reporting software EMIS report Consumption characteristics become transparent and allow an optimization of the energy consumption Easy connection of the M-Bus meter via level converter direct serial to the FRAKO Central Unit EMIS 1500 or- via the internal network (Ethernet TCP/IP) by means of EM-Com-Server M-Bus meters can be evaluated together with all other FRAKO Energy Management devices Product Catalogue EM 167

24 Technical data Power supply Operating voltage 10,8 up to 28 V DC; 10,8 up to 28 V AC Power consumption EM-PW 3: max. 3,6 W; EM-PW20: max. 7 W M-Bus Interface Voltage EM-PW3: 33 V (without load); EM-PW20: 32 V (without load) Standby current EM-PW3: max. 4,5 ma (3 standard loads) EM-PW20: max. 30 ma (20 standard loads) Internal resistance approx. 100 Ohm Overcurrent EM-PW3: 35 ma EM-PW20: 60 ma threshold Transmision rate 300 up to 9600 Baud (RS 232 C) Mechanical construction Dimensions 56x78x117 mm (WxHxD) Ingress protection IP40 Installation on standard rail 35 mm according to DIN EN Operating conditions Ambient 0 up to +50 C temperature Article-No. EM-PW3 EM-PW20 EM-PW 20 TCP EM-PW 100 TCP Product Catalogue EM

25 System-Komponenten EIB Network coupler NK 1 EIB Network coupler The EIB Network coupler is used to connect EIB (KNX) devices with the FRAKO Energy Management System. It connects the EIB (KNX) devices via Ethernet to the Central Unit EMIS Description Building automation becomes important in residential and functional buildings. One solution is the European Installation Bus EIB (KNX) which combines sensors and actuators as well as energy meters into the building automation. The NK1 network coupler is the optimal solution to combine the advantages of EIB (KNX) building automation with the advantages of the FRAKO Energy Management System. Features The EIB (KNX) Network Coupler includes following features: Ethernet RJ45 interface Integrated HTTP-Server Integrated FTP-Server Integration of up to 104 sensors, actuators or energymeters Advantages Connecting EIB (KNX) devices to the FRAKO Energy Management System provides following advantages: Data collected by EIB (KNX) sensors or energy meters with EIB connectivity can be integrated into EMS Database for alarm-management or visualization of energy consumption EIB (KNX) actuators can be used e.g. to visualize alarms Full integration into FRAKO Energy Management System and analyze of collected data with visualization software EMVIS 3000 or reporting software EMIS Report By this EIB (KNX) devices can help to get more transparency which is needed for the optimization of the energy consumption. Product Catalogue EM 169

26 Technical data Power supply Supply voltage 230 V AC Frequency 50 up to 60 Hz Interfaces 1 Ethernet RJ45, connection of LAN Network Protocol: TCP/IP Transmission: 10 / 100 MBit EIB bus terminal red-black Mechanical construction Dimensions 108 x 90 x 65 mm (WxHxD) Ingress protection IP20 Installation on standard rail 35 mm according to DIN EN Mounting position optional Operating conditions Ambient -5 up to +45 C temperature Article-No Product Catalogue EM

27 Maximum demand optimization (demand control) Maximum demand optimization (demand control) Optimization controller Page Extension module (single throw) Page Product Catalogue EM 171

28 172 Product Catalogue EM

29 Maximum demand optimization (demand control) Optimization controller EM-MC 2200 Maximum Controller The EM-MC 2200 Maximum Controller serves as a user-friendly power demand monitor with a power trend calculation function and an optimized switching strategy to prevent the set maximum power (target) demand from being exceeded. Description FRAKO Maximum Demand Controllers ensure maximum savings of active power without disrupting operation. They operate just as well in small stand-alone systems with only a few loads as in major installations with a power demand of several megawatts. They are combined to work with other modular components of the FRAKO Energy Management System to meet specific requirements. Power-dependent control application point to prevent unnecessary load-shedding at the start of the measurement interval Individual adjustment of the connected loads to suit operating conditions by setting priorities, min./max. OFF times and min. ON times per channel To make best use of seasonal demand fluctuations, the self-adapting target demand adjusts itself dynamically to suit the operating conditions of the month concerned. Reducing the target demand at the beginning of the accounting interval combined with the automatic selfadapting function makes additional savings possible in months with low peak loads Formation of switching channel groups for strict compliance with the set priorities 'Traffic light' function: 3 switching channels can be used for signal lamps as a visual guide to demand conditions Emergency load-shedding mode for maintaining the maximum demand even with critical load constellations Connection of intelligent terminals (Wago) to switch off loads Connection of KNX/EIB components via FRAKO Network Coupler NK1 to switch off loads Timer for switching loads to a time schedule or to set time-dependent target demands Storage of the following data in a ring memory: - - Average values per interval over 20,000 intervals including the target power applicable at the end of the interval and the time stamp - - Daily maximum values over 500 days including time stamp - - Monthly maximum values over 48 months ,000 switching cycles Configuration and presentation of momentary and historical measurement readings using Device Manager software (in scope of supply) Display of the measurement readings and the power factor triangle in an EM-FD 2500 Display (an optional graphic display instrument). The Display is connected to the EM-MC 2200 Maximum Controller with a four-core cable. Up to 6 additional EM devices can be viewed at one Display. Product Catalogue EM 173

30 Inputs: 3 inputs for active energy pulses or 2 for active energy and 1 for reactive energy pulses. These can be added, subtracted or used as meters. The selfadapting target demand function can be reset via a volt-free contact 1 input for time pulse; interval duration adjustable from 1 to 1440 minutes 2 inputs for 4 profiles, for adjusting the target demand and/or the settings of the connected loads to suit company-specific factors such as regular and offpeak tariffs. Profile switching can take place via an input to the EMF 1102 Cost Centre and Alarm Unit Outputs: 5 switching and 1 emergency load-shedding channel in the basic instrument (decentralized extendability up to 85 switching channels by means of EMD 1101 Add-on Units, each with 8 relay contacts) 1 alarm contact to signal faults (alarm signal also possible at any desired output) 2 analogue outputs for 2 measurement readings (momentary, trend or target power, corrective power, capacity utilization or remaining time) as 0/4 20 ma or 0 10 V signal, or for infinitely variable control of loads; fed by internal power supply Interfaces: RS 485 Bus, FRAKO Bus protocol to connect to the FRAKO Energy Management System RS 485 extension bus to connect EMD 1101 Add-on Units Ethernet (RJ 45 jack) with the following functions: Communication with the EMD 1101 Add-on Unit or the EMF 1102 Cost Centre and Alarm Unit via the EMG 1500-PN Gateway Output of switching operations via Modbus TCP or the EMG 1500-PN Gateway to the EMD 1101 Add-on Unit Communication with the EMIS 1500 Data Collector Communication with the configuration software at the PC Technical data Power supply Mains voltage Frequency Power consumption Eingänge General 100 V 253 V AC or 100 V 230 V DC 45 up to 65 Hz 7 W / 18 VA S0-Interfaces(DIN43864) for connection of potential free contacts Voltage with open contact: 15 V Max. Line resistance: 800 Ohm Short-circuit current: 18 ma Pulse frequency: 0.1 to 20 Hz 3 Pulse Inputs For power data acquisition from up to 3 meters with pulse outputs. Input 3 can also be used for acquiring reactive power data. 1 Receiver Minutes 2 Profil Inputs to the selection of 4 profiles Outputs 5 Relay contacts bistable, 250V / 2A AC or 30V / 2A DC (Switching channels) 1 Relay contact bistable, 250V / 2A AC or 30V / 2A DC (Notabwurfkanal) 1 Alarm contact break contact 250V / 2A AC or 30V / 2 A DC 1 Extension businterface for connection up to 10 EMD FRAKO Starkstrombus- Interface 1 Displaybus- Interface Operating elements Display elements Connections for connection to FRAKO Energy Management System for optional connection of max. 2 external Displays of Type EM-FD 2500 Operation via external display EM-FD LEDs via plug-in terminals conductor cross-section: max. 1,5 mm² max. 2A external required Fuse protection Mechanical construction Dimensions 296 x 260 x 133 mm (WxHxD) Ingress protection IP30 (Housing), IP10 (terminals) Weight approx. 0,4kg Protection class Protection class II according to DIN/ EN Housing flame-adversely UL 94-V0 Installation on standard rail 35 mm according to DIN EN Operating conditions Ambient 0 C up to +45 C temperature Storage -20 C up to +60 C temperature Article-No Product Catalogue EM

31 Technical data PC requirements for Device-Manager Hardware PC: CPU with min. 2 GHz 1 Gbyte RAM 200 Mbyte free hard disk capacity Software Windows XP, SP 2 with installed.net-framework 3.5 Windows 7 (32 or 64 Bit) Windows 2008 Server R2 Power consumption 7 W / 18 VA Dimensions Product Catalogue EM 175

32 176 Product Catalogue EM

33 Maximum demand optimization (demand control) Extension module (single throw) EMD 1101 Extension Module The Add-on Unit with 8 switching channels can be connected as desired to: EM-MC 2200 Maximum controller or EML 1101 Maximum Demand Controller EMT 1101 System Timer via the FRAKO Starkstrombus Description Display of switching status by LED LED annunciator for bus access Definition of the switching status (on/off) of the individual switching channels if a fault occurs Product Catalogue EM 177

34 Technical data Power supply Mains voltage 230 VAC -15 % up to +10 % Frequency 45 up to 65 Hz Power consumption 4 VA Fuse protection max. 2 A external required Outputs 8 Switching normal open contact 250 VAC / 4 A channels 1 Extension 2-Wire-fieldbus, RS 485 bus / FRAKO Starkstrombus Operating elements 8-fold DIP-switching series, 10-level rotary switch Display elements 9 light emitting diode Connections in cases via connector strip conductor cross-section: max. 2,5 mm² Mechanical construction Dimensions 158x75x120 mm (WxHxD) Ingress protection IP40 Version Protection class 2 according to DIN/ EN Housing flame-adversely UL94-V0 (according to the manufacturer) Installation screw mounting or on standard rail 35 mm according to DIN EN Mounting position wall mounting, vertical Weight approx. 0,8 kg Operating conditions Ambient 0 up to +45 C temperature Storage -20 up to +60 C temperature Article-No Dimensions 178 Product Catalogue EM

35 Mains monitoring Mains monitoring Mains analysis devices for top-hat rail mounting Page Mains analyis devices Page Display units Page Product Catalogue EM

36 180 Product Catalogue EM

37 Mains monitoring Mains analysis devices for top-hat rail mounting Mains analysis devices for top-hat rail mounting The monitoring of currents, harmonics, temperatures, etc. has now become standard practice to uphold supply network quality. The FRAKO Bus and the other components of the system form a powerful energy information system. All data are available centrally. Product Catalogue EM 181

38 EM-PQ 2300 EM-PQ 2200 EM-PQ 2100 EM-PQ 1500 M Voltage VAC or VDC VAC; VDC ± 10% VAC; VDC ± 10% removed from rated voltage Frequency Hz 45/65 Hz 45/65 Hz 50 Hz Power consumption max. 8 W max. 9 VA max. 9 VA max. 7 VA Contact termination 3/4/5-wire / / / / - / / - / / - Current-Measurements 5 x X/5A 4 x X/1A, X/5A 4 x X/1A, X/5A Voltage-Measurements 400/690 VAC (L-N/L-L) 3-phases 5-wire system 277/480 VAC (L-N/L-L) 3-phases 4-wire system 480 VAC (L-L) 3-phases 3-wire system 277/480 VAC (L-N/L-L) 3-phases 4-wire system 480 VAC (L-L) 3-phases 3-wire system 3 x X/5A (transformer current > 6 ma), galvanical isolated 3 x VAC ± 10% (phase-/neutral conductor) 3 x VAC ± 10% (phase-/ neutral conductor) Harmonics V/A Short term interruptions - Active power class 1 0,5 (.../5A); 1 (.../1A) 0,5 (.../5A); 1 (.../1A) 1 Analogue In-/Output - / 2 (0-10 V or 0-20 ma oder 4-20 ma) 1 temperature / - 1 temperature / - Digital In-/Output 4 / 2 2 / 2 2 / 2 - / 1 (max. 30 VDC, 100 ma), (4-20 madc passiv) - / 1 (max. 48 VDC, 100 ma); 1 (max. 30 VDC, 100 ma) Memory Min-/Maxvalue Memory size 256 MB 128 MB 128 MB - Interfaces Ethernet - FRAKO Energy Management System via FRAKO Starkstrombus Intranet (Ethernet) Modbus/TCP Connection via- Modbus RTU (RS 485) or - Modbus/TCP (Ethernet) Connection via- Modbus RTU (RS 485) or - Modbus/TCP (Ethernet) via FRAKO Starkstrombus RS 232 / RS / / / - / - Profibus DP - Webserver / - / / / - / Product Catalogue EM

39 Mains monitoring Mains analysis devices for top-hat rail mounting EM-PQ 2300 Power Quality Analyzer A network monitoring instrument for the acquisition, monitoring and analysis of electrical variables in installations up to 690 V (phasephase) with 5 current transformer inputs and 5 voltage inputs. Description Long-term network analysis as per EN or EN Monitoring of short voltage dips Data records can be selected by the user, for example for analysis of the demand profile Display of measurement readings and waveforms graphically in the EM-FD 2500 Display (optional instrument). The Display is connected to the EM-PQ 2300 Power Quality Analyser by a 4-core cable. Up to 7 EM-PQ 2300 instruments can be served by one EM-FD 2500 Display Inputs: 5 current transformer inputs for L1, L2, L3, N and PE 5 voltage inputs for L1, L2, L3, N and PE, up to 690 V 4 S0 pulse inputs for tariff changeover and trigger input for synchronizing energy metering with the utility company and for acquisition of pulses, status signals and alarms Outputs: 1 alarm contact for up to 230 V AC 2 digital outputs as status contacts for signalling alarms. The outputs are galvanically separated and can work with voltages up to 30 V DC 2 analogue outputs for any desired variables as 0 20 ma, 4 20 ma or 0 10 V signals, operated by internal power supply Interfaces: - - RS485 bus for connection to FRAKO Energy Management System - - Ethernet (RJ45 jack) for internal FRAKO communication with the FRAKO Energy Management System. The internal alarm system can send s via the Ethernet Housed in an enclosure with a pin strip underneath it. This system, consisting of pin and socket strips and DIN rail bus connectors, enables the individual modules to be easily fitted and connected to one another. It is possible to plug individual instruments in or remove them without dismantling the modular assembly. The bus connector allows the Display-Bus, FRAKO Bus and extension bus to be connected. All connections are also available at external terminals at the top of the instrument for conventional wiring. Product Catalogue EM 183

40 Technical data Supply Voltage VAC or VDC Frequency Hz Power consumption max. 8 W Measurement inputs Contact termination / / 3/4/5-wire Current 5 x X/5A measurement inputs Voltage 400/690 VAC (L-N/L-L) measurement 3-Phase 5-wire system inputs In-/Outputs Analog In-/Output - / 2 (0-10 V or 0-20 ma or 4-20 ma) Digital In-/Output 4/2 Interfaces Ethernet FRAKO Energy Management System RS 232 / RS 485 FRAKO Starkstrombus Intranet (Ethernet) - / Profibus DP - Webserver / - / Operating-/Display elements operating via display unit EM-FD 2500 / 5 LEDs Connections pluggable terminal lath Mechanical construction Dimensions 160 x 90 x 96,2 mm (WxHxD) Ingress protection Housing/terminals: according to DIN EN IP30/IP20 Version Protection class 1 according to DIN EN Housing flame-adversely UL94-V0 Installation on standard rail 35 mm according to DIN EN Weight approx. 0,5 kg Operating conditions Ambient C temperature Dimensions Article-No Product Catalogue EM

41 Mains monitoring Mains analysis devices for top-hat rail mounting EM-PQ 2200 Power Quality Analyzer Power Quality Analyzer with 4 current transformer inputs and 4 voltage inputs for top-hat rail mounting to detect, control and analyse electrical measurements in mains up to 480 V (Phase/Phase) (Power quality measurement according to DIN EN :2009 Kl. S, analysis and evaluation according to DIN EN50160). Direct connection to the FRAKO Energy Management System via integrated interfaces RS485 (Modbus RTU) or Ethernet (Modbus TCP/IP). Description Measuring functions: Frequency of fundamental from 15Hz to 440Hz Measuring intervals from 10/12 (50/60 Hz) periods (200 ms) Continuous scanning with 20kHz per channel and calculation of the following measurement readings: Voltage L-N, neutral point displacement voltage Voltage imbalance L1... L3 Voltage L-L Frequency (equally for all channels) Current, total current L1... L3, total current L1... L3+N Power (active, reactive, apparent power, power factor, distortion reactive power) Fundamental power (active, reactive, apparent power, cosphi, phase shift) Summation L1... L3 of the above mentioned performance values Summation L1... L4 (active, reactive, apparent power) Active power (provided and drawn) of the main and ancillary system Reactive power (capacitive and inductive) of the main and ancillary system Fourier analyses 1st... 63rd harmonic component for current, voltage, active and reactive power, as well as interharmonics for every single harmonics per phase Distortion factors (THD) of current andbe voltage - TDD (Total Demand Distortion) L1, L2, L3 Current, short term, long-term flicker Allocation of the measurement readings to generate protocols for voltage and costs Allocation of the measurement readings to generate protocols according to EN50160, EN , Power quality and costs report* Detection and recording: Detection and recording of the minimum, maximum and average value of the measurement readings defined by the user as well as the acquisition periods for histograms of the parameterized time periods Detection of under- and overvoltages U rms Detection of voltage failures U rms Detection of inrush currents (10ms) Detection of transients >50μs Energy meter (active and reactive power, provided and drawn) with 8 tariffs Internal data storage: 128MB Flash memory Device equipment: Display (41x25 mm) Embedded Webserver Product Catalogue EM 185

42 Technical data Inputs: voltage measurement inputs current measurement inputs../1/5a digital inputs: e. g. to change the tariffs, for external synchronisation and to release the records, pulse meter for external consumption meters - - Temperature measurement input for PT100/1000 or KTY83/84 Outputs: digital outputs, can also be programmed as a pulse or signal output Interfaces / Protocols: - - RS485,Protocol: Modbus RTU/Master and Slave for connecting with the FRAKO Energy Management System - - Interface Profibus DP V0, with gateway function - - Ethernet 10/100 TBase Modbus RTU Master/Slave for connecting with FRAKO Energy Management System, Modbus-Gateway, BACnet / IP oder MSTP (optional) - - All interfaces run simultaneously - - Protocols: Modbus TCP/IP (Port 502), Modbus over TCP/IP (Port 8000), HTTP, SMTP, SNMP, SNTP, TFTP, FTP, DHCP - - Built-in homepage for remote maintenance and diagnostics with open structure for application-specific adjustment - - User programmable dispatch, e.g. in case of an alarm - - Supports HTML pages, Java Applets, Flash MX and ActiveX Configuration and visualization software EM-PQ VIS: - - Readout and visualization of measurement readings - - Automatic ring buffer down load of the devices - - Storage of data in a Derby database - - Optional: MS SQL and MySOL database drivers - - Graphical representation and analysis of online- and offline-measurement readings - - Freely configurable topology with freely selectable register levels - - Configuration of the measurement devices - - Parameterisation, visualization, data management, analysis - - Cost centre management - - Report function (EN 50160, Voltage and cost centres) for freely definable time periods - - Statistics function - - Data export into a CSV file - - Possibility of customer specified programming (SPSfunctionality) - - The following operating systems are supported: - Windows XP (ab Service Pack 3) - Windows Vista (ab Service Pack 1) - Windows 7, - MAC OS (ab 10.5), - Linux und - Unix Programming: Integrated Interpreter to create customized user programms, e.g. alarms, cost centre entry, operating conditions,.... Freely accessible internal variables (measurement readings...) via reloadable user programms 7 user programs can run at the same time Overvoltagekategorie 300V CAT III Rated voltage in max. 277/480VAC, +10% 4-wire system Rated voltage in max. 480V AC, +10% 3-wire system Frequency of 45-65Hz (15-440Hz*) fundamental Power consumption 0,1VA Auxiliary voltage L-N V AC; V DC Power consumption 9VA Current.../1A/5A measurement Minimum working 5mA current Power consumption 0,2VA Voltage ± 0,2% Current ± 0,2 Power ± 0,4% Active power Class 0,5S at.../5a Active power Class 1 at.../1a Reactive power Class 2 at.../1/5a Operational C ambient temperature Protection class IP20 Dimensions 107,5(6 TE) x 90 x 82 mm (WxHxD) Inklusive Configuration and visualization software EM-PQ VIS; Patch cable, 3m, blue. (EM-PQ - switch/hub connection); Patch cable, 2m, twisted, grey. (EM- PQ - PC connection) Article-No Optional accessory Type Description Article-No. EM-PQ-VIS Configuration und online representaion software for Power Quality Monitor for EM-PQ 2100, 2200, 2500 und Dimensions 186 Product Catalogue EM

43 Product Catalogue EM 187

44 188 Product Catalogue EM

45 Mains monitoring Mains analysis devices for top-hat rail mounting EM-PQ 2100 Power Quality Analyzer Power Quality Analyzer with 4 current transformer inputs and 4 voltage inputs for top-hat rail mounting to detect, control and analyse electrical measurements in mains up to 480 V (Phase/Phase) (Power quality measurement according to DIN EN :2009 Kl. S). Direct connection to the FRAKO Energy Management System via integrated interfaces RS485 (Modbus RTU) or Ethernet (Modbus TCP/IP). Description Measuring functions: Frequency of fundamental from 45Hz... 65Hz Measuring intervals from 10/12 (50/60 Hz) periods (200 ms) Continuous scanning with 20kHz per channel and calculation of the following measurement readings: Voltage L-N, neutral point displacement voltage Voltage imbalance L1... L3 Voltage L-L Frequency (equally for all channels) Current, total current L1... L3, total current L1... L3+N Power (active, reactive, apparent power, power factor, distortion reactive power) Fundamental power (active, reactive, apparent power, cosphi, phase shift) Summation L1... L3 of the above mentioned performance values Summation L1... L4 (active, reactive, apparent power) Active power (provided and drawn) of the main and ancillary system Reactive power (capacitive and inductive) of the main and ancillary system Fourier analyses 1st... 40th harmonic component for current, voltage, active and reactive power, as well as interharmonics for every single harmonics per phase Distortion factors (THD) von current und voltage - TDD (Total Demand Distortion) L1, L2 Current, short term, long-term flicker Allocation of the measurement readings to generate protocols for voltage and costs Allocation of the measurement readings to generate protocols according to EN50160, EN Detection and recording: Detection and recording of the minimum, maximum and average value of the measurement readings defined by the user as well as the acquisition periods for histograms of the parameterized time periods Detection of under- and overvoltages U rms Detection of voltage failures U rms Detection of inrush currents (10ms) Detection of transients >50μs Energy meter (active und reactive power, provided and drawn) with 8 tariffs Internal data storage: 128MB Flash memory Device equipment: Display (41x25 mm) Embedded Webserver Product Catalogue EM 189

46 Technical data Inputs: voltage measurement inputs current measurement inputs../1/5a digital inputs: e. g. to change the tariffs, for external synchronisation and to release the records, pulse meter for external consumption meters - - Temperature measurement input for PT100/1000 or KTY83/84 Outputs: digital outputs, can also be programmed as a pulse or signal output Interfaces / Protocols: - - RS485,Protocol: Modbus RTU/Master and Slave for connecting with the FRAKO Energy Management System - - RS232,Protocol: Modbus RTU/Slave (nur EM-PQ 2100) - - Ethernet 10/100 TBase Modbus RTU Master/Slave for connecting with the FRAKO Energy Management System, Modbus-Gateway, BACnet / IP oder MSTP (option) - - All interfaces run simultaneously - - Protocols: Modbus TCP/IP (Port 502), Modbus over TCP/IP (Port 8000), HTTP, SMTP, SNMP, SNTP, TFTP, FTP, DHCP - - Built-in homepage for remote maintenance and diagnostics with open structure for application-specific adjustment - - User programmable dispatch, e.g. in case of an alarm - - Supports HTML pages, Java Applets, Flash MX and ActiveX Configuration and visualization software EM-PQ VIS: - - Readout and visualization of measurement readings - - Automatic ring buffer down load of the devices - - Storage of data in a Derby database - - Optional: MS SQL and MySOL database drivers - - Graphical representation and analysis of online- and offline-measurement readings - - Freely configurable topology with freely selectable register levels - - Configuration of the measurement devices - - Parameterisation, visualization, data management, analysis - - Cost centre management - - Report function (Voltage and cost centres) for freely definable time periods - - Statistics function - - Data export into a CSV file - - Possibility of customer specified programming (SPSfunctionality) - - The following operating systems are supported: - Windows XP (ab Service Pack 3) - Windows Vista (ab Service Pack 1) - Windows 7, - MAC OS (ab 10.5), - Linux und - Unix Programming: Integrated Interpreter to create customized user programms, e.g. alarms, cost centre entry, operating conditions,... Freely accessible internal variables (measurement readings...) via reloadable user programms 7 user programs can run at the same time Overvoltagekategorie 300V CAT III Rated voltage in max. 277/480VAC, +10% 4-wire system Rated voltage in max. 480V AC, +10% 3-wire system Frequency of 45-65Hz (15-440Hz*) fundamental Power consumption 0,1VA Auxiliary voltage L-N V AC; V DC Power consumption 9VA Current.../1A/5A measurement Minimum working 5mA current Power consumption 0,2VA Voltage ± 0,2% Current ± 0,2 Power ± 0,4% Active power Klasse 0,5S bei.../5a Active power Klasse 1 bei.../1a Reactive power Klasse 2 bei.../1/5a Operational C ambient temperature Protection class IP20 Dimensions 107,5(6 TE) x 90 x 82 mm (WxHxD) Inklusive Configuration and visualization software EM-PQ VIS; Patch cable, 3m, blue. (EM-PQ - switch/hub connection); Patch cable, 2m, twisted, grey. (EM- PQ - PC connection) Article-No Optional accessory Type Description Article-No. EM-PQ-VIS Configuration und online representaion software for Power Quality Monitor for EM-PQ 2100, 2200, 2500 und Product Catalogue EM

47 Dimensions Product Catalogue EM 191

48 192 Product Catalogue EM

49 Mains monitoring Mains analysis devices for top-hat rail mounting EM-PQ 1500 M Power Quality Monitor Power Quality measurement system to detect, analyze and monitor electrical measurement variables in 400 V low voltage mains and medium voltage mains (100 V secondary). Description Monitoring and evaluation of the mains quality; measurement of all relevant mains data in low and medium voltage mains Energy meter for active power (input and output) and reactive power Different measurements over 10 periods (200 ms, see EN ), measuring range up to the 40th harmonic (distortion factor current/voltage, absolute value of harmonic current) 4 voltage and 3 current measurement inputs Bimetallic function Integrated alarm management with different output configurations: 2x contact outputs, display, LED Easily extendable to include up to 15 measurement units via 2 link connections (max. 40 m) for displaying all relevant data via the display EM-FD outputs: adjustable digital/analogue (digital, 4-20 ma/ alarm individually programmable) Connection to the FRAKO Energy Management System via FRAKO Starkstrombus (RS 485) Top hat rail mounting Product Catalogue EM 193

50 Technical data Measurement inputs Voltage path (Phase-Null) 3x V AC +/- 10 % (Phase-Phase) 3x V AC +/- 10 % Frequency 50 Hz Power consumption max. 7 VA Fuse protection max. 2 A external protection required Current path 3x X/5A (transformer current >6mA) Power consumption max. 1,8VA je Wandleranschluss Eingänge Display IN 24V DC, voltage input für Displayeinheiten mit einem 24V Steuermodul Outputs Digital OUT max.48v DC, max 100 ma DC Digital/Analog OUT max. 30V DC, max. 100 ma (DC 4-20 ma passiv) Interfaces 1 FRAKO Starkstrombus For connection to FRAKO Energy Management System, according to EN 50170(P-Net) standardised fieldbus, RS 485 Transfer speed: 76,8 kbit/s Art/ Protocol: RS 485 / P-Net 2 Link-Connections Connection to further EM-PQ 1500 (max. 15 St) zur Anzeige über eine Displayeinheit EM-FD 1500 Art/ Protocol: CAN/ FRAKO internal Display Connection to display unit EM-FD 1500 Mechanical construction Dimensions 160 x 102 x 67 mm (WxHxD) Ingress protection Housing/Terminals IP40/20 Version according to DIN EN , DIN EN and DIN EN Housing flame-retardant UL94-V0 Installation on standard rail 35 mm according to DIN EN Mounting position optional Weight approx. 0,5 kg Operating conditions Ambient 0 up to +55 C temperature Optional accessory Type Description Article-No. RJ 45 Patch- Kabel für EM-PQ 1500; Länge: 1 m RJ45 patch cable for connecting EM-PQ 1500 Power Quality Monitor to another EM-PQ 1500, cable length 1 m RJ 45 Patch- Kabel für EM-PQ 1500; Länge: 3 m RJ 45 Patch- Kabel für EM-PQ 1500; Länge: 5 m RJ 45 Patch- Kabel für EM-PQ 1500; Länge: 10 m Interface- Adapter EM-PQ- RS 232 Netzteil für Analog Modul EM-AM 24VDC (auch für EM-PQ 1500 verwendbar) EM-PQ-SW RJ45 patch cable for connecting EM-PQ 1500 Power Quality Monitorto another EM-PQ 1500, cable length 3 m RJ45 patch cable for connecting EM-PQ 1500 Power Quality Monitorto another EM-PQ 1500, cable length 5 m RJ45 patch cable for connecting EM-PQ 1500 Power Quality Monitor to another EM-PQ 1500, cable length 10 m RS232 adapter for direct PC access to data from EM-PQ 1500, with EM- PQSW configuration and display software, cable length 3 m AC/DC SMPS adapter, DIN rail-mounted, 24 V DC / 0.35 A and 12 V DC / 20 ma, AC power supply 85 to 264 V (also suitable for EM-PQ 1500) Software for the configuration and online display of data from the EM-PQ 1500 Power Quality Monitor Link via: EMIS 1500, EMP 1100, EMT 1101 and EM-PQ RS232 adapter Note: included with FRAKO-NET when supplied on CD-ROM Article-No Product Catalogue EM

51 Dimensions Product Catalogue EM 195

52 196 Product Catalogue EM

53 Mains monitoring Mains analysis devices Mains analysis devices The monitoring of currents, harmonics, temperatures, etc. has now become standard practice to uphold supply network quality. The FRA- KO Bus and the other components of the system form a powerful energy information system. All data are available centrally. Product Catalogue EM 197

54 EM-PQ 3000 EM-PQ 2500 EMA 1101 EMA 1296 Voltage VAC; VDC ± 10% VAC; VDC ± 10% 230 VAC ± 10% VAC or VDC ± 20% Frequency 45/65 Hz 45/65 Hz Hz 50/60 Hz ± 10% Power consumption max. 9 VA max. 9 VA max. 7VA max. 5VA Contact termination 3/4/5-wire Current measurements inputs Voltage-Measurements / / - / / - / / - 4 x X/1A, X/5A 4 x X/1A, X/5A 417/720 VAC (L-N/L-L) 3-phases 4-wire systems 480 VAC (L-L) 3-phases 3-wire systems 417/720 VAC (L-N/L-L) 3-phases 4-wird systems 480 VAC (L-L) 3-phases 3-wire systems 3 x X/5A (transformer current > 6 ma), galvanical isolated 3 x VAC (phase-/phase conductor); 3 x VAC (phase-/phase conductor) / / - ; wire and single-phase 3 x X/5A (X adjustable of A); 3 x VAC (phase-/phase conductor), Overload 800 VAC; 3 x VAC (phase-/neutral conductor), Overload 800 VAC Harmonics V/A Short term interruptions - - Active power class 0,2 (.../5A) 0,2 (.../5A) 2 2 Analogue In-/Outputs - / - - / - 2 temperature inputs / - - / - Digital In-/Outputs 8 / 5 8 / 5 Collective input for selection of 2 profiles/ 1 alarm signalling contact 250 VDC, max. 3 A - / optional Plug-In Module for active and reactive power Memory Min-/Maxvalue Memory size 256 MB 256 MB - - Interfaces Ethernet - - FRAKO Energy Management System Connection via- Modbus RTU (RS 485) or - Modbus/TCP (Ethernet) Connection via- Modbus RTU (RS 485) or - Modbus/TCP (Ethernet) via FRAKO Starkstrombus optional Plug-In module enable the connection via Modbus RTU RS 232 / RS / - / (optional at EMA 1101, EMA V) / - - / - Profibus DP (only -DP - Varianten) - Webserver / - / - / - / - - / Product Catalogue EM

55 Mains monitoring Mains analysis devices EM-PQ 3000 Power Quality Analyzer Mains monitoring device class A for control panel installation to detect, monitor and analyze electrical measurement variables in mains up to 720 V (phase/phase) with 4 current transformer inputs and 4 voltage outputs. Direct connection to the FRAKO Energy Management System via integrated interfaces RS485 (Modbus RTU) or Ethernet (Modbus TCP/IP). Description Measuring functions: Frequency of fundamental 15Hz Hz Measuring intervals from 10/12 (50/60 Hz) periods (200 ms) Continuous scanning with 20kHz per channel and calculation of the following measurement readings: Voltage L-N, neutral point displacement voltage Voltage imbalance L1... L3 Voltage L-L Frequency (equally for all channels) Current, total current L1... L3, total current L1... L3+N Power (active, reactive, apparent power, power factor, distortion reactive power) Fundamental power (acitve, reactive, apparent power, cosphi, phase shift) Summation L1... L3 of the above mentioned performance values Summation L1... L4 (active, reactive, apparent power) Active power (provided and drawn) of the main and ancillary system Reactive power (capacitive and inductive) of the main and ancillary system Fourier analyses 1st... 63rd harmonic component dor current, voltage, active and reactive power, as well as interharmonics for every single harmonics per phase Distortion factors (THD) von current und voltage TDD (Total Demand Distortion) L1, L2, L3 Current, short term, long-term flicker Allocation of the measurement readings to generate protocols according to EN50160, EN , Power quality and costs report Detection and recording: Detection and recording of the minimum, maximum and average value of the measurement readings defined by the user as well as the acquisition periods for histograms of the parameterized time periods Detection of under- and overvoltages U rms Detection of voltage failures U rms Detection of inrush currents (10ms) Detection of transients >50μs Energy meter (active und reactive power, provided and drawn) with 8 tariffs Internal data storage: 256 MB Flash memory Device equipment: Active matrix display (TFT B115xH88 mm), resolution (Pixel) 320x240, brightness (cd/m2)300, screen diagonal 5,7 inch Embedded Webserver Product Catalogue EM 199

56 Technical data Eingänge: Voltage measurement inputs Current measurement inputs../1/5a digital inputs: e. g. to change the tariffs, for external synchronisation and to release the records, pulse meter for external consumption meters digital outputs, can also be programmed as a pulse or signal output Interfaces / Protocols: - - RS485,Protocol: Modbus RTU/Master and Slave for connecting with the FRAKO Energy Management System - - Interface Profibus DP V0, with gateway function - - Ethernet 10/100 TBase Modbus RTU Master/Slave for connecting with the FRAKO Energy Management System, Modbus-Gateway, BACnet / IP oder MSTP (option) - - All interfaces run simultaneously - - Protocols: Modbus TCP/IP (Port 502), Modbus over TCP/IP (Port 8000), HTTP, SMTP, SNMP, SNTP, TFTP, FTP, DHCP - - Built-in homepage for remote maintenance and diagnostics with open structure for application-specific adjustment - - User programmable dispatch, e.g. in case of an alarm - - Supports HTML pages, Java Applets, Flash MX and ActiveX Configuration and visualization software EM-PQ VIS: - - Readout and visualization of measurement readings - - Automatic ring buffer down load of the devices - - Storage of data in a Derby database - - Optional: MS SQL and MySOL database drivers - - Graphical representation and analysis of online- and offline-measurement readings - - Freely configurable topology with freely selectable register levels - - Configuration of the measurement devices - - Parameterisation, visualization, data management, analysis - - Cost centre management - - Report function (EN 50160, voltage and cost centres) for freely definable time periods - - Statistics function - - Data export into a CSV file - - Possibility of customer specified programming (SPSfunctionality) - - The following operating systems are supported: - Windows XP (ab Service Pack 3) - Windows Vista (ab Service Pack 1) - Windows 7, - MAC OS (ab 10.5), - Linux und - Unix Programming: Integrated Interpreter to create customized user programms, e.g. alarms, cost centre allocation, operating conditions,... Freely accessible internal variables (measurement readings...) via reloadable user programms 7 user programs can run at the same time Overvoltagekategorie 600V CAT III Rated voltage in max. 417/720VAC, +10% 4-wire system Rated voltage in max. 480V AC, +10% 3-wire system Frequency of 45-65Hz auxiliary voltage Power consumption 15VA Auxiliary voltage L-N V AC; V DC Power consumption 15VA Current.../1A/5A measurement Minimum working 5mA current Power consumption 0,2VA Measurement Klasse A (gemäß IEC ) method and measurement precision Voltage ± 0,1% Current ± 0,2 Power ± 0,2% Active power Klasse 0,2S bei.../5a Active power Klasse 0,5S bei.../1a Reactive power Klasse 2 bei.../1/5a Operational C ambient temperature Relative humidity 5 up to 95% Protection class Front IP50, Rückseite IP20 Dimensions 144 x 144 x 81 mm (WxHxD) Inklusive Configuration and visualization software EM-PQ VIS; Patch cable, 3m, blue. (EM-PQ - switch/hub connection); Patch cable, 2m, twisted, grey. (EM- PQ - PC connection); Befestigungsklammern Article-No Product Catalogue EM

57 Optional accessory Type Description Article-No. Stecker DB-9 MIT Terminierung Terminal plug DB-9 Buchse (with screw terminals) Stecker DB-9 OHNE Terminierung EM-PQ-VIS Dimensions Terminal plug DB-9 Buchse (with screw terminals) Configuration und online representaion software for Power Quality Monitor for EM-PQ 2100, 2200, 2500 und Product Catalogue EM 201

58 202 Product Catalogue EM

59 Mains monitoring Mains analysis devices EM-PQ 2500 Power Quality Analyzer Mains monitoring device for control panel installation to detect, monitor and analyze electrical measurement variables in mains up to 720 V (phase/phase) with 4 current transformer inputs and 4 voltage inputs. Direct connection to the FRAKO Energy Management System via integrated interfaces RS485 (Modbus RTU) or Ethernet (Modbus TCP/IP) Description Measuring functions: Frequency of fundamental 40Hz... 70Hz Measuring intervals from 10/12 (50/60 Hz) periods (200 ms) Continuous scanning with 20kHz per channel and calculation of the following measurement readings: Voltage L-N, neutral point displacement voltage Voltage imbalance L1... L3 Voltage L-L Frequency (equally for all channels) Current, total current L1... L3, total current L1... L3+N Power (active, reactive, apparent power, power factor, distortion reactive power) Fundamental power (active, reactive, apparent power, cosphi, phase shift) Summation L1... L3 of the above mentioned performance values Summation L1... L4 (active, reactive, apparent power) Active power (provided and drawn) of the main and ancillary system Reactive power (capacitive and inductive) of the main and ancillary system Fourier analyses 1st... 40th harmonic component (harmonics) for current, voltage, active and reactive power - Distortion factors (THD) von current und voltage Allocation of the measurement readings to generate protocols for voltage and costs Detection and recording: Detection and recording of the minimum, maximum and average value of the measurement readings defined by the user as well as the acquisition periods for histograms of the parameterized time periods Detection of under- and overvoltages U rms Detection of voltage failures U rms Detection of inrush currents (10ms) Detection of transients >50μs Energy meter (active und reactive power, provided and drawn) with 8 tariffs Internal data storage: 256 MB Flash memory Device equipment: Active matrix display (TFT B115xH88 mm), resolution (Pixel) 320x240, brightness (cd/m2) 300, screen diagonal 5,7 inch Embedded Webserver Product Catalogue EM 203

60 Technical data Inputs: Voltage measurement inputs Curent measurement inputs../1/5a digital inputs: e. g. to change the tariffs, for external synchronisation and to release the records, pulse meter for external consumption meters Outputs: digital outputs, can also be programmed as a pulse or signal output Interfaces / Protocols: - - RS485,Protocol: Modbus RTU/Master and Slave for connecting with the FRAKO Energy Management System - - Interface Profibus DP V0, mit Gatewayfunktion - - Ethernet 10/100 TBase Modbus RTU Master/Slave for connection to FRAKO Energy Management System, Modbus-Gateway, BACnet / IP oder MSTP (option) - - All interfaces run simultaneously - - Protocols: Modbus TCP/IP (Port 502), Modbus over TCP/IP (Port 8000), HTTP, SMTP, SNMP, SNTP, TFTP, FTP, DHCP - - Built-in homepage for remote maintenance and diagnostics with open structure for application-specific adjustment - - User programmable dispatch, e.g. in case of an alarm - - Supports HTML pages, Java Applets, Flash MX and ActiveX Configuration and visualization software EM-PQ VIS: - - Readout and visualization of measurement readings - - Automatic ring buffer down load of the devices - - Storage of data in a Derby database - - Optional: MS SQL and MySOL database drivers - - Graphical representation and analysis of online- and offline-measurement readings - - Freely configurable topology with freely selectable register levels - - Configuration of the measurement devices - - Parameterisation, visualization, data management, analysis - - Cost centre management - - Report function (Voltage and cost centres) for freely definable time periods - - Statistics function - - Data export into a CSV file - - Possibility of customer specified programming (SPSfunctionality) - - The following operating systems are supported: - Windows XP (ab Service Pack 3) - Windows Vista (ab Service Pack 1) - Windows 7, - MAC OS (ab 10.5), - Linux und - Unix Pogramming: Integrated interpreter to create customized user programs, e.g. alarms, cost centre allocation, operating conditions,... Freely accessible internal variables (measurement readings ) via reloadable user programms 7 user programs can run at the same time Overvoltagekategorie 600V CAT III Rated voltage in4- max. 417/720VAC, +10% wire system Rated voltage in max. 480V AC, +10% 3-wire system Frequency of 45-65Hz auxiliary voltage Power consumption 0,1VA Auxiliary voltage L-N V AC; V DC Power consumption 15VA Current.../1A/5A measurement Minimum working 5mA current Power consumption 0,2VA Voltage ± 0,1% Current ± 0,2 Power ± 0,2% Active power Klasse 0,2 bei.../5a Active power Klasse 0,5 bei.../1a Reactive power Klasse 2 bei.../1/5a Operational ambient C temperature Relative humidity 5 up to 95% Protection class Front IP50, back-side IP20 Dimensions 144 x 144 x 81 mm (WxHxD) Inclusive Configuration and visualization software EM-PQ VIS; Patch cable, 3m, blue. (EM-PQ - switch/hub connection); Patch cable, 2m, twisted, grey. (EM- PQ - PC connection); Befestigungsklammern Article-No Product Catalogue EM

61 Optional accessory Type Description Article-No. Stecker DB-9 MIT Terminierung Terminal plug DB-9 Buchse (mit Schraubklemmen) Stecker DB-9 OHNE Terminierung EM-PQ-VIS Dimensions Terminal plug DB-9 Buchse (mit Schraubklemmen) Configuration und online representaion software for Power Quality Monitor for EM-PQ 2100, 2200, 2500 und Product Catalogue EM 205

62 206 Product Catalogue EM

63 Mains monitoring Mains analysis devices EMA 1101 Mains monitoring unit Microprocessor 3-phase measurement and monitoring unit with optional connection to the FRAKO Starkstrombus to detect, analyse and monitor electrical measurement variables in 400 V and 525 V low voltage mains or medium voltage mains (100 V, secondary) Description Measurement via three external current converters Automatic range switch-over Measurement of active demand for incoming and recovery power Menu-driven in plain text and 6 parameters displayed for direct comparison Alarm on exceeding set limits with potential-free NO contact as well as plain text shown on a flashing backlit display Visualisation of the currents as a bar graph to determine the utilization capacity Menu-driven programming in plain text with operato prompts Backlit display Storage of all meter readings and limit values on mains failure Illuminated LC display of measured values Product Catalogue EM 207

64 Technical data Power supply Mains voltage 230 VAC +/- 10 % Power consumption max. 7 VA Fuse protection 2 A external protection required Messeingang Voltage path 3x 250 to 550 VAC (external- / external conductor) Power consumption: max. 1,0 VA per external conductor Fuse protection: 2 A external required Strompfad 3x X/ 5 A (transformer current > 6 ma) Power consumption: max. 1,8 VA per transformer connection Outputs 1 Alarm signalling contact Inputs Tariff input 250 VAC / max. 3 A (potential-free NO contact) To select from 2 profiles (e.g. HT/LT) Interfaces (mode can be selected) 1 FRAKO Starkstrombus RS 232-Interface Operating elements Display elements Connections Mechanical construction For connection to FRAKO Energy Management System, according to EN 50170(P-Net), standardised fieldbus, RS 485 bit rate: 76,8 kbit/s Can be directly connected to a PC via RS232 interface direkt an PC anschließbar bit rate: Baud Membrane keyboard with 5 keys Illuminated LC display (4 lines each of 20 characters) Plug-in connecting strips (supplied) Dimensions Front plate dimensions: 144 x 144 mm(din 43700) Switch panel aperture: 138 x 138 mm(din 43700) Installation depth: 105 mm Ingress protection Housing/Terminals IP54/20 according to VDE 0470 / EN60529 Version nach VDE 0411 / EN61010 Contamination level 3, EN 50081, EN Housing flame-retardant UL94-V0 Installation From front panel with screwdriver Mounting position optional Weight approx. 1,3 kg Operating conditions Ambient 0 C up to +50 C temperature Versions Type Description Article-No. EMA 1101 S 3-phase measurement and monitoring unit without connection interface to the FRAKO Starkstrombus to detect, analyse and monitor electrical measurement variables in 400V and 525V low voltage mains. Can be upgraded to full version using Software EMA-SW via FRAKO Energy Management System or Interface Adapter EM-RS 232 EMA phase measurement and monitoring unit with optional connection to the FRAKO Starkstrombus to detect, analyse and monitor electrical measurement variables in 400V and 525V low voltage mains EMA V 3-phase measurement and monitoring unit with optional connection to the FRAKO Starkstrombus to detect, analyse and monitor electrical measurement variables in medium voltage mains (100VAC secondary) EMA 1101 DP 3-phase Mains Monitoring Instrument with Profibus DP interface for measuring, analysing and monitoring electrical variables in 400 V and 525 V low voltage networks EMA 1101 DP 105V 3-phase measurement and monitoring unit with Profibus-DP interface to detect, analyse and monitor electrical measurement variables in medium voltage mains (100 VAC secondary) Product Catalogue EM

65 EMA 1101 S EMA 1101 EMA V EMA DP EMA DP 105V For use in 3-phase 400 V and 525 V low voltage mains For use in medium voltage mains (100 V secondary) Optional connection to the FRAKO Starkstrombus Profibus DP interface Determination of current in PEN (neutral + PE) Bar chart of the currents and distortion factors Can be connected to a PC or modem using an RS232 interface (optional) Optional accessory Type Description Article-No. EM-RS 232 RS 232 adapter for direct PC access to the data of EMA 1101, EMR 1100 or EMF EMA 1101 version 1.11 and later; EMR 1100 version 1.95 and later; EMF 1102 version 1.0 and later EM-RS 232 für RS 232 adapter for Modembetrieb access to the data of EMA 1101, EMR 1100 or EMF 1102 via modem. EMA 1101 version 1.11 and later; EMR 1100 version 1.95 and later; EMF 1102 version 1.0 and later EMA-SW Software for the configuration and online display of the mains monitoring device EMA Access via: EMIS 1500, EMP 1100 or RS 232 adapter Note: included with FRAKO-NET when supplied on CD-ROM Product Catalogue EM 209

66 Dimensions 210 Product Catalogue EM

67 Mains monitoring Mains analysis devices EMA 1296 Mains Monitoring Unit 3-phase measurement and monitoring unit to detect, analyse and monitor electrical measurement variables in low voltage mains from 50 to 500 VAC. Description Collection of all relevant measurement readings: Voltage measurement Phase/Phase and Phase/Neutral Current measurement for all phases (momentary and max-values) Apparent, active and reactive power (active power as momentary and max-values) Power factor (inductive and capacitive) Frequency Energy meters for active and reactive work Current measuring via current transformer x / 5A Backlit LCD screen with 3 measurement readings (refreshing 1/sec) External power supply Front panel integration Product Catalogue EM 211

68 Technical data Power supply AC voltage 110 up to 440 V AC at 50/60 Hz ± 10 % DC voltage 120 up to 350 V DC ± 20 % Power consumption < 5 VA Measurements Network types 3-phase (3- oder 4 wire), 2-phase (2 wire), and single phase system Voltage Phase/Phase 50 up to 500 V AC Phase/Neutral 28 up to 289 V AC Sustained overload 800 V AC Current Transformer input 3x X / 5 A (X adjustable between 5 and 9999 A) Minimum 5 ma measurable current Sustained overload 6 A Power consumption < 0,6 VA Indicated current 0 up to 11 ka (1,1 x primary current) Indicated power 0 up to 11 MW/Mvar/MVA Indicated frequency von 45,0 up to 65,0 Hz Measurement 1 second update interval Measurement accuracy Current 0,2 % from 10 up to 110 % x I n Voltage 0,2 % from 140 up to 700 V AC Power 0,5 % of full scale reading Power Factor 0,5 % for 0,5 < PF < 1 Frequency 0,1 % from 45 to 65 Hz Active energy ± 0,5% (IEC class 0,5S) metering Reactive energy ± 2% (IEC class 2) metering Operating elements 4 keys Display elements Backlit LCD screen Connections Plug-in connectors 2.5 mm 2 (voltage and instrument power) Fixed terminals 6 mm 2 (current) Mechanical construction Dimensions 96 x 96 x 60 (WxHxD )oder 80 mm with Plug-in modules Ingress protection Front IP52 Housing IP30 Weight 400 g Operating conditions Ambient 10 C up to +55 C temperature Optional accessory Type Description Article-No. EMA EXT IMP Programmable pulse output (type, rate and duration) for EMA Active or reactive work (kwh+ or kvarh+ can be provided for FRAKO Cost Center and Alarm System EMF 1102 or PLC. EMA EXT MOD Connection of EMA 1296 to FRAKO Energy Management System can be realized via this interface RS 485 and protocol JBUS/ MODBUS Article-No Product Catalogue EM

69 Mains monitoring Display units Display units The monitoring of currents, harmonics, temperatures, etc. has now become standard practice to uphold supply network quality. The FRA- KO Bus and the other components of the system form a powerful energy information system. All data are available centrally. EM-FD 2500 EM-FD 1500 Voltage supplied by EM device 24 VDC ± 15% or VAC Frequency - 50/60 Hz Power consumption max. 3 VA max 3 VA Operating-/ Displayelement Interfaces CAN-Bus 9 Buttons / bright LC-Display / 1 LED 9 Buttons / bright LC-Display RS 232 / RS Product Catalogue EM 213

70 214 Product Catalogue EM

71 Mains monitoring Display units EM-FD 2500 Display unit Graphical display for easy display of the measurement readings and waveforms of up to 7 Energy Management devices of the latest generation Description Simply mount display unit with 2 x Ø 22.5 mm holes in panel Only one cable from the display unit to the power quality monitor Connection of max. 8 Energy Management devices via display bus Product Catalogue EM 215

72 Technical data Power supply Voltage Fuse protection Power consumption Connections Leiterquerschnitt Interfaces 11 V up to 16 V DC, polarity protection,mains supply by the attached EM unit Intern via 500 ma SMD fuse max. 3 VA via plug-in terminals max. 1,5 mm² Displaybus CAN nach ISO 11898, RS 485, impedance level 120 Ohm Transfer rate: 1 Mbit/s Bus length: max. 40 m Mechanical construction Dimensions mm (W H D) including connector, overlap 23 mm cabinet depth max. 30 mm including connector Ingress protection Front IP 54 bei Verwendung der beiliegenden Dichtmatte, Gehäusefront IP 50 ohne Dichtmatte, Terminals und Klemmenbereich IP 20, pollution degree 3, alle Angaben nach DIN EN Installation in Frontwand / Türe mittels einer zentralen Bohrung Ø 22,5 mm und einer Bohrung zur Verdrehsicherung, Ø 3,5 mm Version Enclosure insulated, Protection class 3 (SELV), load voltage up to max. 16 V EMV EMV according to EN , EN Electrostatic Discharge Air 8 kv and Conductive 4 kv with horizontal and vertical coupling plate, EN EMS Radiated 80 MHz - 1GHz, horizontal and vertical, Level 10 V/ m = irradation industries Class B, EN Burst 1 kv capacitive auf Anschlusskabel, EN 55022A EMI 30 MHz - 1 GHz = Abstrahlung Wohnbereich Class A Weight 330 g Operating conditions Temperature range 0 up to +60 C, no dewing Installation height Geographic heigt max m Optional accessory Type Description Article-No. Adapter plate for EM-FD 2500 Adapter for the installation of an EM-FD 2500 into a switchboard cut-out(138x138mm) Article-No Product Catalogue EM

73 Mains monitoring Display units EM-FD 1500 Display unit Display unit EM-FD 1500 for connection to Power Quality Monitor EM-PQ Description Data indication of up to 15 Power Quality Monitors EM- PQ 1500 Control cable between EM-PQ 1500 and EM-FD 1500 (max 10 m) Clear text menu with backlit LCD screen and keys Frontpanel mounting by two Ø22,5mm punched holes Technical data Anschluss Power Supply (control unit) Trigger Control Distance EM-FD V DC: 24 V DC +/- 5% EM-FD V AC: 230 VAC +/- 10 % EM-FD V DC: 7 pole Control cable, min. 0,30mm² per lead EM-FD V AC: 5 pole Control cable, min. 0,30mm² per lead max. 10 m between EM-FD 1500 and EM-PQ 1500 Mechanical construction Dimensions (WxHxD) Display unit: 87 x 87 x 21 mm Control unit: 75 x 58 x 37 mm Protection class Display unit: IP65 when mounted Mounting Panel with thickness max 6 mm Mounting position optional Weight approx. 0,3 kg Operating conditions Ambient temperature 0 up to +55 C, Betauung ist zu vermeiden Product Catalogue EM 217

74 Versions Type Description Article-No. EM-FD V DC-package (incl. power supply) Display unit EM-FD for connection to Power Quality Monitor EM-PQ 1500; 24 V DC, incl. power supply EM-FD V DC-package (without power supply) EM-FD V ACpackage Display unit EM-FD 1500 for connection to Power Quality Monitor EM-PQ 1500; 24 V DC, without power supply Display unit EM-FD 1500 for connection to Power Quality Monitor EM-PQ 1500; 230 V AC Display unit EM-FD 1500 Module 24 V DC Module 230 V AC Connecting cable 2,5 m (EM-PQ 1500 with module 24 V DC) Connecting cable 2,5 m (EM-PQ 1500 with module 230 V AC) 2 ferrule resistor for EM-PQ 1500 Power supply 24 V DC EM-FD V DC +NT EM-FD V DC EM-FD V AC 218 Product Catalogue EM

75 Cost allocation / Cost center acquisition Cost allocation / Cost center acquisition Direct measuring meter Page Measuring transformer meter Page Counting ans message device Page Acquisition of environmentally relevant variables Page Product Catalogue EM 219

76 220 Product Catalogue EM

77 Cost allocation / Cost center acquisition Direct measuring meters Direct measuring meters For 1- or 3 phase mains - 1x 230V or 3x 57,7/100V /400V - 65A or 90A direct connection - 1A and 5A transformer connection in one device - PTB-approval. Product Catalogue EM 221

78 EMC 1201 EMC 1203 DVH EM-EC 380 / EM-EC 380 MID* EM-PM 380 Direct measuring meter Measurements obtained active energy obtained reactive energy recovery active energy - - recovery reactive energy calibratable (PTB) 1) - / (MID)* - calibrated - 1) - - accuracy class (active energy / reactive energy) 1/- 2/- B/2 B/2 Impulses Number/obtained active energy (T1 und T2) 1 Number / obtained reactive energy (T1 und Ts) - Number / recovery active energy Interfaces Infrared interface for connection with the - - communication modules Modbus RTU / M-Bus - - KNX-EIB (Energy und - - demand) 1) abhängig von Variante: EMC 1203 MDVH: nicht geeicht, eichfähig (PTB), geeicht (PTB) EMC 1203 DVH: eichfähig (PTB), geeicht (PTB) 222 Product Catalogue EM

79 Cost allocation / Cost center acquisition Direct measuring meter EMC 1201 Electronic energy meter Single phase electronical energy meter for 10(65) A Direct connection for detection of active power in 230 V low-voltage grids Description calibratable / validation (PTB approval) Precision class 1 Version corresponds to IEC / EN S0 output according to EN , reverse polarity protection Pulse valency 1 Wh/Imp. sealable DIN module case 2 TE, rail-mounting Technical data Power supply Supply voltage taken from measurement voltage Measurements optained active/ / - reactive energy recovery active/ - /- reactive energy Approval calibratable (PTB)* Precision class active/reactive energy: 1/- Contact termination 2-wire Current measurement Transformer x/... - Directly up to 65 A Ratio adjustable - Power consumption < 0,1 VA Current inputs - galvanically isolated Voltage measurement Voltage 1 x 230 V +/- 10% measurement Power consumption 1,5 VA Product Catalogue EM 223

80 Frequency 50 Hz Pulse output SO (potential-free contact) Number/use 1/optained active energy Valency 100 Imp/kWh Duration min. 30 ms Strain up to 230 VAC / 100 ma LED 1000 Imp/kWh LC-Display - (illuminated) Detection of faulty - connection Tariffs - Mechanical construction Dimensions 35,8 x 97,6 x 61,1 mm, 2 TE Ingress protection Housing: IP51 Terminal block with terminal cover: IP20 Conductor crosssection Installation Weight Transfomer: - Direct: 16 mm2 Standard rail 35 mm 0,2 kg Operating conditions Operating -20 up to +55 C temperature Article-No * calibrated (PTB) on demand 224 Product Catalogue EM

81 Cost allocation / Cost center acquisition Direct measuring meter EMC 1203 DVH Energy meter for direct connection Three-/four-wire system. three phase electronic energy meter for 65 A direct connection for detecting active power in low voltage systems. Description Precision class 2 Version corresponds to IEC / EN Pulse output SO concerning to DIN 43864, pulse valence R A = 5000 Imp/kWh, pulse duration min. 30 ms, can also be used as a potential-free contact (up to 230 V AC/DC 100 ma) Detection of faulty connections Sealable DIN module case 7 TE, rail-mounting Normschiene 35 mm nach DIN EN Technical data Power supply Supply voltage Measurements optained active/ reactive energy recovery active/ reactive energy Approval taken from measurement voltage / - - / - 2 Versions: calibratable (PTB) and calibrated (PTB) Precision class active/reactive energy: 2*/- Contact termination 4-wire Current measurement TRansformer x/... - Directly up to 65 A Ratio adjustable - Power consumption 1,0 VA/Phase Current inputs - galvanically isolated Voltage measurement Stress field 3 x 230/400 V +/- 10% Power consumption 1,5 VA Frequency 50 Hz Pulse output SO (potential-free contact) Number/use 1/optained active energy Valency 500 Imp/kWh Duration min. 30 ms Strain up to 230 VAC / 100 ma LED 1000 Imp/kWh LC-Display - (illuminated) Detection of faulty connection Tariffs - Product Catalogue EM 225

82 Mechanical construction Dimensions 125 x 96 x 66 mm (BxHxT), 7 TE Ingress protection Housing: IP51 Terminal block with terminal cover: IP20 Conductor crosssection Installation Weight Transformer: - Direkt: 25 mm2 Standard rail 35 mm 0,5 kg Operating conditions Operating -20 up to +55 C temperature Dimensions Versions Type Description Article-No. EMC 1203 DVH 3-phase Energy Meter with 3/4-wire connections, calibrated EMC 1203 DVH 3-phase Energy Meter with 3/4-wire connections Optional accessory Type Description Article-No. EMC 1203 DVH/MDVH Frontrahmen Front frame (7 TE) for installation of the Energy Meter in the door of a switchboard cabinet. Not suitable for Energy Meters EMC 1203, EMC 1203 I and EMC 1203 D Product Catalogue EM

83 Cost allocation / Cost center acquisition Direct measuring meter EM-EC 380 / EM-EC 380 MID Energy meter Four-wire system, three phase energy meter for detecting active und reactive power in low voltage systems with counter mit Zählwerk, performance indication and output for active and reactive pulse. Current inputs (x/5a) are galvanically isolated. EM-EC 35 MID: MID calibrated Description one pulse per optained and recovery active energy Power measuring: value and bar lateral Infrared Interface for connecting other communication modules, Modbus RTU / M-Bus for the following values: U, I, PF, F; KNX-EIB for energy and power, Technical data Power supply Supply voltage taken from measurement voltage Measurements optained active/ / reactive energy recovery active/ / reactive energy Approval EM-EC 380: - EM-EC 380 MID: calibrated (MID) Precision class active/reactive energy: B/2 Contact termination 2- bis 4-wire Current measurement Transformer x/... - Directly up to 80 A Ratio adjustable - Power consumption 0,8 VA/Phase Current inputs - galvanically isolated Voltage measurement Stress field 3 x 230/400 V +/- 20% Power consumption 0,5 VA Frequency 50 Hz Pulse output SO (potential-free contact) Number/use 1/optained active energyt1 und T2 1/optained reactive energy T1 und T2 Valency 500 Imp/kWh Duration 30 +/- 2 ms Strain VAC/90 ma, VDC/90 ma LED 1000 Imp/kWh LC-Display (illuminated) Detection of faulty connection Tariffs 2 Product Catalogue EM 227

84 Mechanical construction Dimensions 72 x 90 x 70 mm (BxHxT), 4TE Ingress protection Housing: IP51 Terminal block with terminal cover: IP20 Conductor crosssection Installation Weight Transformer: - Direct: 35 mm2 Standard rail 35 mm 0,4 kg Operating conditions Operating -10 up to +55 C temperature Dimensions Versions Type Description Article-No. EM-EC 380 Four-wire system, three phase energy meter EM-EC 380MID Four-wire system, three phase energy meter, calibrated Product Catalogue EM

85 Cost allocation / Cost center acquisition Direct measuring meter EM-PM 380 Energy meter Four-wire system, three phase energy meter for measurement detecting of I, U, PF, F as well as all power ratings in low voltage systems. Description Measurement of energy consumption and energy output Pulse output Current inputs are galvanically isolated one pulse per optained and recovery active energy Measurement of I, U (Ph/Ph), U (Ph/N), PF, F as well as all power ratings per phase lateral Infrared Interface for connecting other communication modules, Modbus RTU / M-Bus for above mentioned values, KNX-EIB for energy and power Technical data Power supply Supply voltage taken from measurement voltage Measurements optained active/ / - reactive energy recovery active/ / - reactive energy Approval - Precision class active/reactive energy: B/2 Contact termination 2- up to 4-wire Current measurement Transformer x/... - Directly up to 80 A Ratio adjustable - Power consumption 0,8 VA/Phase Current inputs - galvanically isolated Voltage measurement Stress field 3 x 230/400 V +/- 20% Power consumption 0,5 VA Frequency 50 Hz Pulse output SO (potential-free contact) Number/use 1/optained active energy T1 und T2 1/optained reactive energy T1 und T2 Valency 2000 Imp/kWh oder einstellbar Duration 30 +/- 2 ms Strain VAC/90 ma, VDC/90 ma LED 1000 Imp/kWh LC-Display Detection of faulty connection Tariffs - Product Catalogue EM 229

86 Mechanical construction Dimensions 72 x 90 x 70 mm (BxHxT), 4TE Ingress protection Housing: IP51 Terminal block with terminal cover: IP20 Transformer: - Direct: 35 mm2 Standard rail 35 mm 0,4 kg Operating conditions Operating -10 up to +55 C temperature Dimensions Article-No Optional accessory Conductor crosssection Installation Weight Type Description Article-No. EM-CM MOD-Buscommunications MODBUS module. The communication between the module and the energy meter is carried out via the infrared interface. Values: energy and power, U, I, PF and F. EM-CM MBUS M-Bus-communications module. The communication between the module and the energy meter is carried out via the infrared interface. Values: energy and power, U, I, PF and F EM-CM SD- Card EM-CM KNX SD-Card Datalogger with SD-Card. The communication between the module and the energy meter is carried out via the infrared interface. EIB/KNXcommunications module The communication between the module and the energy meter is carried out via the infrared interface. Values: energy and power. 230 Product Catalogue EM

87 Cost allocation / Cost center acquisition Measuring transformer meter Measuring transformer meter For 1- or 3 phase mains - 1x 230V or 3x 57,7/100V /400V - 65A or 90A direct connection - 1A and 5A transformer connection in one device - PTB-approval. Product Catalogue EM 231

88 EMC 1203 MDVH EMC ETAR EM-EC 35 / EM-EC 35 MID* EM-PM 35 Measuring transformer meter Measurements obtained active energy obtained reactive - - energy recovery active energy - - rückgespeiste recovery reactive energy calibratable 1) - - / (MID)* - calibrated 1) accuracy class (active energy/reactive energy) 1/- 1/2 B/2 B/2 Impulses Number/obtained active energy (T1 and T2) 1 Number/obtained reactive energy (T1 and Ts) - Number/recovery active energy Interfaces Infrared interface for connecting of - - communication modules Modbus RTU / M-Bus - - KNX-EIB (energy and - - power) 1) abhängig von Variante: EMC 1203 MDVH: nicht geeicht, eichfähig (PTB), geeicht (PTB) EMC 1203 DVH: eichfähig (PTB), geeicht (PTB) 232 Product Catalogue EM

89 Cost allocation / Cost center acquisition Measuring transformer meter EMC 1203 MDVH Energy meter mit Wandleranschluss Four-wird, three phase ernergy meter for detecting active power in low voltage systems. Description Precision class 1 Version corresponds to IEC / EN Pulse output SO concerning to DIN 43864, pulse valence R A = 5000 Imp/kWh, pulse duration min. 30 ms, can also be used as a potential-free contact (up to 230 V AC/DC 100 ma) Detection of faulty connections Sealable DIN module case 7 TE, rail-mounting Normschiene 35 mm nach DIN EN Technical data Power supply Supply voltage Measurements optained active/ reactive energy recovery active/ reactive energy Approval taken from measurement voltage / - - / - 3 Versions: ratio adjustable, calibratable (PTB) und calibrated (PTB) Precision class active/reactive energy: 1/- Contact termination 4-wire Current measurement Transformer x/... 1 A und 5 A Direkt bis - Ratio adjustable 1, 10, 20, 30, 40, 50, 60, 80, 100, 120, 150, 200, 250, /1; 5, 50, 100, 150, 200, 250, 300, 400, 500, 600, 750, 1000, 1250, /5 Energy meters with PTB approval: input deactivated Power consumption 1,0 VA/Phase Current inputs galvanically isolated Voltage measurement Stress field 3 x 230/400 V +/- 10% Power consumption 1,5 VA Product Catalogue EM 233

90 Frequency 50 Hz Pulse output SO (potential-free contact) Number/use 1/optained active energy Valency 5000 Imp/kWh Duration min. 30 ms Strain up to 230 VAC / 100 ma LED 1000 Imp/kWh LC-Display - (illuminated) Detection of faulty connection Tariffs - Mechanical construction Dimensions 125 x 96 x 66 mm (BxHxT), 7 TE Ingress protection Housing: IP51 Terminal block with terminal cover: IP20 Conductor crosssection Installation Weight Transformer: - Direkct: 25 mm2 Standard rail 35 mm 0,5 kg Operating conditions Operating -20 up to +55 C temperature Optional accessory Type Description Article-No. EMC 1203 DVH/ MDVH front frame Front frame (7 TE) for mounting the energy meter (EMC 1203 DVH / EMC 1203 MDVH) in a cabinet door Versions Type Description Article-No. EMC 1203 MDVH Three-/Four-wire system, three phase energy meter Ratio adjustable EMC 1203 MDVH EMC 1203 MDVH Three-/Four-wire system, three phase energy meter, calibratable 3-phasiger energy meter in 3/4-Leitertechnik, calibrated Product Catalogue EM

91 Cost allocation / Cost center acquisition Measuring transformer meter EMC ETAR Energy meter Three-/Four-wire system, three phase energy meter for detecting active und reactive power in low and medium voltage systems with counter and output for active and reactive pulse Description Current inputs are galvanically isolated Technical data Power supply Supply voltage taken from measurement voltage Measurements optained active/ / reactive energy recovery active/ - / - reactive energy Approval - Precision class active/reactive energy: 1/2 Contact termination 3-/4-wire Current measurement Transformer x/... 1 A und 5 A Direkt bis - Ratio adjustable x/1 oder x/5; Power consumption 0,8 VA/Phase Current inputs galvanically isolated Voltage measurement Stress field 3 x 57,7 / 100 V... 3 x 230/400 V +/- 15% Power consumption < 1 VA, 1 W Frequency 50/60 Hz Pulse output SO (potential-free contact) Number/use 1/optained active energy 1/optained reactive energy Valency 0,1 Wh/Imp kwh/imp, 0,1 varh/imp...100kvarh/imp Dauer ms Strain VAC/100 ma, VDC/100 ma LED 1 Imp/Wh / 1 Imp/varh LC-Display (illuminated) Detection of faulty connection Tariffs - Product Catalogue EM 235

92 Mechanical construction Dimensions 122,5 x 100 x 58,5 mm (BxHxT); 7 TE Ingress protection Housing: IP51 Terminal block with terminal cover IP20 Conductor crosssection Installation Weight Transformer: 6 mm2 Direkt: - Standard rail 35 mm 0,4 kg Article-No Optional accessory Type Description Article-No. EMC ETAR front frame Front frame (7 TE) for mounting the energy meter (EMC ETAR) in a cabinet door Dimensions 236 Product Catalogue EM

93 Cost allocation / Cost center acquisition Measuring transformer meter EM-EC 35 / EM-EC 35 MID Energy meter Four-wire system, three phase energy meter for detecting active und reactive power in low voltage systems with counter, performance indication and output for active and reactive pulse. Current inputs (x/5a) are galvanically isolated. EM-EC 35 MID: MID calibrated Description one pulse per optained and recovery active energy Power measuring: value and bar lateral Infrared Interface for connecting other communication modules, Modbus RTU / M-Bus for above mentioned values, KNX-EIB for energy and power Technical data Power supply Supply voltage taken from measurement voltage Measurements optained active/ / reactive energy recovery active/ / reactive energy Approval EM-EC 35: - EM-EC 35 MID: calibrated (MID) Precision class active/reactive energy: B/2 Contact termination 4-wire Current measurement Transformer x/... 5 A Directly up to - Ratio adjustable x/5; ; smallest step:5 Power consumption 0,7 VA/Phase Current inputs galvanically isolated Voltage measurement Stress field 3 x 230/400 V +/- 20% Power consumption 0,5 VA Frequency 50 Hz Product Catalogue EM 237

94 Pulse output SO (potential-free contact) Number/use 1/optained active energy T1 und T2 1/optained reactive energy T1 und T2 Valency I primär A = 100 Imp/kWh bzw. Imp/ kvarh, A = 10 Imp/kWh bzw. Imp/ kvarh, A = 1 Imp/kWh bzw. Imp/kvarh Duration 30 +/- 2 ms Strain VAC/90 ma, VDC/90 ma LED Imp/kWh LC-Display (illuminated) Detection of faulty connection Tariffs 2 Mechanical construction Dimensions 72 x 90 x 70 mm (BxHxT), 4TE Ingress protection Housing: IP51 Terminal block with terminal cover: IP20 Conductor crosssection Installation Weight Transformer: 6 mm2 Direct: - Standard rail 35 mm 0,4 kg Operating conditions Operating -10 up to +55 C temperature Versions Type Description Article-No. EM-EC 35 Four-wire system, three phase energy meter EM-EC 35 MID Four-wire system, three phase energy meter, calibrated Optional accessory Type Description Article-No. EM-CM MOD-Buscommunications MODBUS module. The communication between the module and the energy meter is carried out via the infrared interface. Values: energy and power U, I, PF und F. EM-CM MBUS M-Bus-communications module. The communication between the module and the energy meter is carried out via the infrared interface. Values: energy and power U, I, PF und F EM-CM SD- Card EM-CM KNX Dimensions SD-Card Datalogger with SD-Card. The communication between the module and the energy meter is carried out via the infrared interface. EIB/KNXcommunications module. The communication between the module and the energy meter is carried out via the infrared interface. values: energy and power Product Catalogue EM

95 Cost allocation / Cost center acquisition Measuring transformer meter EM-PM 35 Energy meter Four-wire system, three phase energy meter for measurement detecting of I, U (Ph/Ph), U (Ph/N), PF, F as well as all power ratings per phase. Description Measurement of energy consumption and energy output Pulse output Current inputs are galvanically isolated one pulse per optained and recovery active energy Measurement of I, U (Ph/Ph), U (Ph/N), PF, F as well as all power ratings per phase lateral Infrared Interface for connecting other communication modules, Modbus RTU / M-Bus for above mentioned values, KNX-EIB for energy and power Technical data Power supply Supply voltage taken from measurement voltage Measurements optained active/ / - reactive energy recovery active/ / - reactive energy Approval - Precision class active/reactive energy: B/2 Contact termination 4-wire Current measurement Transformer x/... 5 A Directly up to - Ratio adjustable x/5; ; smallest step:5 Power consumption 0,7 VA/Phase Current inputs galvanically isolated Voltage measurement Stress field 3 x 230/400 V +/- 20% Power consumption 0,5 VA Frequency 50 Hz Product Catalogue EM 239

96 Pulse output SO (potential-free contact) Number/use 1/optained active energy T1 und T2 1/optained reactive energy T1 und T2 Valency adjustable (dependent on the current transformer) Duration 30 +/- 2 ms Strain VAC/90 ma, VDC/90 ma LED Imp/kWh LC-Display Tariffs - Mechanical construction Dimensions 72 x 90 x 70 mm (BxHxT), 4TE Ingress protection Housing: IP51 Terminal block with terminal cover: IP20 Conductor crosssection Installation Weight Transformer: 6 mm2 Direct: - Standard rail 35 mm 0,4 kg Operating conditions Operating -10 up to +55 C temperature Article-No Optional accessory Type Description Article-No. EM-CM MOD-Buscommunications MODBUS module. The communication between the module and the energy meter is carried out via the infrared interface. Values: Energy and power U, I, PF and F. EM-CM MBUS M-Bus-communications module. The communication between the module and the energy meter is carried out via the infrared interface. Values: Energy and power U, I, PF und F EM-CM SD- Card EM-CM KNX SD-Card Datalogger with SD-Card. The communication between the module and the energy meter is carried out via the infrared interface. EIB/KNXcommunications module. The communication between the module and the energy meter is carried out via the infrared interface. Values: Energy and power Dimensions 240 Product Catalogue EM

97 Cost allocation / Cost center acquisition Counting and message device EMF 1102 Counting and Message Device The EMF 1102 is a compact and cost-effective system for the aquisition and storage of meter readings, switching status and alarm signals. Description It consists of a data acquisition and memory unit plus modular software components for easy user configuration and for the evaluation and management of the data. Remote alarms can be transmitted by SMS via modem. The EMF 1102 can be used as a stand-alone system for the acquisition of utilities and operating data in a factory or other premises, or can be installed as an integral part of a FRAKO Energy Management System. Data acquisition for all types of utility such as electricity, water, gas, compressed air, or meter pulse inputs via an S0 interface: Calculation of power, energy and flow rates Monitoring of power, energy or flow rate with high and low alarm settings Determination of running time and downtime for each channel (running time meter) Operating cycle counter Monitoring of operating times and downtimes with alarm settings (e.g. to detect instrument failure) Monitoring of key operating conditions Remote alarms by SMS in an event of system faults or if monitored variables exceed critical limits Storage of all utility data with memory for several days Connection: - via RS232 adapter with modem or COM server or direct to PC or via FRAKO Starkstrombus to the EMP communications process or the EMZ bus central unit Option of visualizing and evaluating the meter data through the FRAKO Energy Management System software module (EMVIS 3000) Option of displaying, configuring and evaluating the recorded data via the PC by means of the EMF-SW cost centre and alarm software Product Catalogue EM 241

98 Technical data Power supply Mains voltage 230 VAC +/- 10 % Frequency 45 up to 65 Hz Power consumption approx. 10 VA Eingänge General S0-Interface (DIN 43864) for connection of potential-free contacts, common 'E-'-Potential switching time: >= 25 ms Voltage with open contact: 12 VDC +/- 10 % Short circuit current: 12 ma +/- 10 % 12 Pulse Inputs Pulse frequency: max. 20 Hz internal switching shaft: Off' at approx. 3 ma, 'On' at aaprox. 7.5 ma Outputs 1 Voltage output 12 VDC, max. 50 ma Interfaces (Betriebsart wahlweise) 1 FRAKO Starkstrombus RS 232-Interfaces Display elements Connections for connection to FRAKO Energy Management System, according to EN 50170(P-Net), standardised fieldbus, RS 485 transfer speed: 76,8 kbit/s Optional via RS232-Adapter direct connectabel to the PC transfer speed: Baud 14 light emitting diodes screw terminal conductor cross-section: max. 2,5 mm² Mechanical construction Dimensions 140x90x59 mm (BxHxT), DIN Module cases 8 TE Ingress protection Housing/terminals IP40/20 Version Protection class II according to VDE 0411 / DIN EN Housing flame-adversely UL94-V0 Installation on standard rail 35 mm according to DIN EN Mounting position optional Weight approx. 0,6 kg Operating conditions Ambient 0 up to +60 C temperature Optional accessory Type Description Article-No. EM-RS 232 RS 232-Adapter for PC-direct access to the data of EMA 1101 (from SW-Version 1.11), EMR 1100 (from SW-Version 1.95) and EMF 1102 (from SW-Version 1.0) EM-RS 232 for modem operation RS 232-Adapter for access to the data of EMA 1101 (from SW- Version 1.11), EMR 1100 (from SW-Version 1.95) or EMF 1102 (from SW- Version 1.0) via modem registration license EMF 1102 EMF-SW Dimensions License allows EMVIS 3000 access to a cost center and alarm system EMF 1102, if these account is a virtual data collector Display, analysis and configuration software for cost centers and alarm system EMF Access via: EMIS 1500, EMP 1100, EMT 1101 and RS 232-Adapter. Info: Including in the delivery of FRAKO-NET (by CD-shipment) Article-No Product Catalogue EM

99 Cost allocation / Cost center acquisition Acquisition of environmentally relevant variables EM-PF Flow sensor for compressed air Flow sensor with micro controlled transmitter for the measurement of air-flow velocity and for the determination of the flow rate and flow volume. Description Recording of the consumption kurves Does the compressor work in its best possible way? Are the compressors efficiently managed? Determination of the consumption data How much does the machine/complex consume? Visualize the costs of the compressed air Determination of the maximum flow rate Is there any reserve capacity? Energy Contracting Cost allocation of the compressed air in industrial areas Easy installation Socket welding (½ inch) Conversion of the measured air velocity into a pulse frequency (0-20 Hz) Power supply via optional 24 VDC mains supply circuit Leakage detection Consumption in case of a shutdown = Leakage Leakage detection within compressed air networks Control of the air ventilation in cleanrooms and in waste water treatrment plants Consumption measurement of nitrogen CO 2 and other protective gas up to a pressure of 16 bar Cost center accounting Costs per complex or department Billing via the FRAKO Energy Management System Product Catalogue EM 243

100 Technical data Power supply Supply voltage 24 VDC +/- 20% Power consumption approx. 3 VA Outputs General Potential-free switching contact acording to SO-Norm (DIN 43864) external power supply: max. 27 ma High/Low signal level: = 10 ma / = 2 ma 1 switching output max. pulse frequency: 20 Hz Messmedium Luft Measurement range m/s Operating temperature -20 up to +85 C Working pressure 7 bar Temperature dependency Pressure dependency Zero correction Connecting cable compensating within the operating temperature range independent of medium pressure press-related flow curve adjustment 4 x 0,34 mm2, 5 m Mechanical construction Installation length EM-PF 180 MM: 180 mm EM-PF 200 MM: 200 mm EM-PF 250 MM: 250 mm EM-PF 350 MM: 350 mm Ingress protection Housing IP65 Version Protection class 3 according to DIN VDE 0106 part 1, EN , EN Weight approx. 0,5 kg Versions Type Description Article-No. EM-PF 180 MM Flow sensor with micro controlled transmitter; probe-length: 180 mm (0-60 m/s, 0-20 Hz, 16 bar) EM-PF 250 MM Flow sensor with micro controlled transmitter; probe-length: 250 mm (0-60 m/s, 0-20 Hz, 16 bar) EM-PF 200 MM Flow sensor with micro controlled transmitter; probe-length: 200 mm (0-60 m/s, 0-20 Hz, 8 bar) EM-PF 350 MM Flow sensor with micro controlled transmitter; probe-length: 350 mm (0-60 m/s, 0-20 Hz, 8 bar) Product Catalogue EM

101 Cost allocation / Cost center acquisition Acquisition of environmentally relevant variables EM-PT 100 Temperature sensor Temperature sensor in four wire technology to measure temperatures together with the Temperature-/Frequency Converter EM-PTF, dem Power Quality Analyzer EM-PQ 2300 oder the mains analysis device EMA Technical data Rated value 100 Ohm bei 0 C Temperatur range -80 up to +260 C Material Stainless steel Dimensions Sensor sleeve 4 mm diameter, 50 mm length Connecting cable 1000 mm length Optional accessory Type Description Article-No. EM-PT100 MF Mounting flange for the temperature sensor Article-No Product Catalogue EM 245

102 246 Product Catalogue EM

103 Cost allocation / Cost center acquisition Acquisition of environmentally relevant variables EM-RFPT Humidity-/Temperature sensor For acquiring operating data with the FRAKO Energy Management System a measured temperature (0 up to 50 C) as well as the measured relative humidity (0 up to 100 %) will be transformed into an analog output signal (4 up to 20 ma). The sensor is an ideal solutiion for the HVAC sector. Description Power is supplied via an external 24 VDC power supply (not included in scope of delivery). Technical data Power supply with external 24 VDC power supply (not included in scope of delivery) Relative humidity Sensor HC200 Output % 4 up to 20 ma r.f. Operational range %r.f. Accuracy at 20 C +/-3% r.f. ( %) Temperature effect typ. -0,05 % r.f./ C at 45% r.f. Temperature Sensor PT1000 (Tolerance Class. B, DIN EN 60751) Output C 4 up to 20 ma Operational range %r.f. Accuracy at 20 C +/-0,5 C Connections PG7 cable gland,in housing with screw terminals wire cross-section: max. 1,5 mm² Mechanical construction Dimensions Basic unit: 80x80x35 mm (WxHxD) Probe length/diameter.: 82 / 12 mm Sensor protection Membrane filter Ingress protection IP40 Version electromagnetic compatibility according to EN and EN Housing material Polycarbonat Installation Wall mounting Mounting position optional Weight approx. 110 g Operating conditions Ambient -5 up to +50 C temperature Storage -25 up to +60 C temperature Article-No Product Catalogue EM 247

104 248 Product Catalogue EM

105 Cost allocation / Cost center acquisition Acquisition of environmentally relevant variables EM-UIF Voltage-/Current-/Frequency-converter For acquiring operating data with the FRAKO Energy Management System. Description For acquiring operating data with the FRAKO Energy Management System an analog signal 0-10 V or 2-10 V (direct voltage) or 0-20 ma or 4-20 ma (continuous current) is transformed into a pulse frequency 0-5 Hz. The pulse output of the EM-UIF is connected to the cost center and alarm system EMF This offers the possibility to control, detect and visualize sensors with random output signals with the FRAKO Energy Management System. Technical data Power supply Mains voltage 230 VAC +/-20 % Frequency 45 up to 65 Hz Power consumption 2,5 VA Input Input variable Continuous current or direct voltage Rated value 0 up to 20 ma, 4 up to 20 ma, Ri=3 Ohm 0 up to 10 V, 2 up to 10 V, Ri=160 kohm Overloads current 2 times at current; 5 times at voltage Stoßüberlastung 20 fach 1 sec bei current; 5 fach at voltage Output Rated value 0 up to 5 Hz OPEN-Kollektor npn, max. 30 V, 100 ma belastbar Ingress protection IP40 Version Housing insulated, Protection class 2, at rated voltage upt to 300 V (net to neutral conductor) pollution degree 2, according to DIN EN part 1 EMV according to DIN EN and DIN EN Installation on standard rail 35 mm according to DIN EN Operating conditions Ambient -15 up to +55 C temperature Article-No Product Catalogue EM 249

106 Dimensions 250 Product Catalogue EM

107 Cost allocation / Cost center acquisition Acquisition of environmentally relevant variables EM-PTF Temperature-/Frequency-converter For acquiring operating data with the FRAKO Energy Management System the measured inlet temperatures from 40 to +120 C will be transformed into a pulse frequency from 0 to 5 Hz. Description The pulse output of the EM-PTF is connected to the cost center and alarm system EMF This offers the possibility to control, detect and visualize temperatures with the FRAKO Energy Management System. Technical data Power supply Mains voltage 230 VAC +/-20 % Frequency 45 up to 65 Hz Power consumption 2,5 VA Input Input variable Resistor PT100 Rated value -40 up to 120 C, constant current via the detector 2 ma Methods of connection Two-wire circuit Three-wire circuit Four-wire circuit 2-/3-or 4-wire, can be selected by DIL-switch Connection max. adjustment 10 Ohm via built-in potentiometer Connection max. 100 Ohm, symmetrically, no adjustment is required Connection max. 100 Ohm, no adjustment is required Output Rated value 0 up to 5 Hz OPEN-Kollektor npn, max. 30 V, 100 ma belastbar Impuls / Pause 50/50 % Connections screw terminals wire cross-section: max. 4 mm² Mechanical construction Dimensions 22,5x84x108 mm (WxHxD) Ingress protection Housing/Terminals IP30/20 according to DIN EN Version Housing insulated, pollution degree 2, Overvoltage category CAT 3 according to DIN EN Teil 1, EMV according to DIN EN , DIN EN Installation on standard rail 35 mm according to DIN EN Weight approx.. 0,15 kg Operating conditions Ambient -15 up to +55 C temperature Article-No Product Catalogue EM 251

108 Dimensions 252 Product Catalogue EM

109 Cost allocation / Cost center acquisition Acquisition of environmentally relevant variables EM-AM 2108 Analog module Data acquisition system for 8 analog, freely configurable input channels. This allows to detect and visualize sensors with random output signals with the FRAKO Energy Management System. Description 8 analog inputs, alternatively:- temperature -50 up to 150 C over 5 K NTC - 0 / 4 up to 20 ma or - 0 up to 10 V) Monitoring of temperatures and analog signals with upper and lower alarm limit External supply voltage 9 up to 36 V DC Connection with FRAKO Starkstrombus Resolution temperature range: 0,1 C; Accuracy entire temperature range: 1 C Resolution voltage range: 10 mv; max. error: 30 mv Resolution current range: 20 µa; max.error: 60 µa Easy configuration of the EM-AM 2108 via EM-AM-SW software For each input of the analog module the current measurement readings as well as the maximum and the minimum value of the last interval will be displayed via the EM-AM- SW software By integrating the EM-AM 2108 into the FRAKO Energiy Informations-System all temperatures and analog signals will be captured and monitored with their upper and lower alarm limits The system visualization software EMVIS 3000 allows to analyse and visualize the data Product Catalogue EM 253

110 Technical data Power supply Mains voltage Power consumption Input Input variable Nominal value Overload constant Stoßüberlastung Temperature measurement Current measurement Voltage measurement Connections Interface 1 FRAKO Starkstrombus 9 up to 36 V DC 0,72 VA Continuous current or direct voltage 0 up to 20 ma, 4 up to 20 ma,ri=130 Ohm,0 up to 10V,Ri=115,13 kohm 2,5 times at current; 2,5 times at voltage 5 times 1 s at current; 5 times 1 s at voltage Range: -50 up to 150 C Resolution: approx. 0,1 C Accuracy:1,5 C (-50 up to -25 C),1,0 C (-25 up to +100 C), 2,0 C (+100 up to +125 C),3,5 C (+125 up to +150 C) Range: 0 up to 20 ma; 4 up to 20 ma Resolution: 20 µa; max. failure: 60 µa Range: 0 up to 10 V Resolution: 10 mv; max. failure: 30 mv screw terminals wire cross-section: max. 1,4 mm² For connection to FRAKO Energy Management System, according to EN 50170(P-Net), standardised fieldbus, RS 485 transfer speed: 76,8 kbit/s 2 LEDs Display elements Mechanical construction Dimensions 86x128x50 mm (BxHxT) Ingress protection Housing/Terminals IP30/IP20 according to DIN EN Version Housing insulated, Protection class 3 (SELV), at a rated voltage up to max. 36 V, pollution degree 2, according to EN Teil1, EMV according to EN Installation on standard rail 35 mm according to DIN EN Weight 190 g Operating conditions Ambient 0 up to +70 C temperature Article-No Product Catalogue EM

111 Power factor control relay with bus interface Power factor control relay with bus interface Page Product Catalogue EM 255

112 256 Product Catalogue EM

113 Power factor control relay with bus interface EMR 1100 S / EMR 1100 Power Factor Control Relay Power Factor Control Relay for intelligent control and monitoring of Power Factor Correction with interface for FRAKO Starkstrombus. Please refer to chapter "Power Factor Control Relays" under "Power Factor Correction" Product Catalogue EM 257

114 258 Product Catalogue EM

115 Software Software Visualization software Page Cost center handling software Page EMG-OPC-Server Page Product Catalogue EM 259

116 260 Product Catalogue EM

117 Software Visualization software EMVIS 3000 System-Visualization The FRAKO Energy Management System is used to acquire measurement readings, statuses and events from a company s entire internal utilities supply system. These data are processed centrally and saved, and can be displayed and evaluated using the EMVIS 3000 visualization software. Description The EMVIS 3000 software is a powerful tool for displaying and documenting all the measurement data for the instruments connected to it. It comprises the following functional modules: EMVIS 3000 Report A clear overview of the entire system is displayed in two system trees (physical and organizational) to simplify navigation Presentation of historical data for analysis and comparison purposes, e.g. different locations or different periods in time The historical data can be exported for further processing Direct access to the momentary readings of the connected instruments Readout of the events that have occurred EMVIS 3000 Live Navigation through individually created views from site layout drawings right down to the distribution board Display of the momentary measured variables and statuses EMVIS 3000 Project Flexible configuration and summarizing of assessments in the organizational system tree Easy customizing individual projects with customized views simple and intuitive (included in the basic package: three views with up to 20 data points) The software license enables EMVIS 3000 to access an EMIS 1500 Central Unit. Technical data PC-requirements for small and medium systems Hardware min. 3 GHz Processor Dual-Core 4 GB working memory 1 GB free hard disk memory Software Windows 7 (x32/x64) Windows Server (2003 R2/2008 R2) Windows DOT NET 4.0 SP1 * registered trademarks of Microsoft Coorporation FRAKO-NET V (or newer) SQL Datenbank Firebird 2.0 (included in FRAKO-NET) Article-No Product Catalogue EM 261

118 EasyCustomizing supplementary package Type Description Article- No. EasyCustomizing-S maximal 100 data points, maximum 100 individual designed views EasyCustomizing-M maximal 200 data points, maximum 100 individual designed views EasyCustomizing-L maximal 350 data points, maximum 100 individual designed views EasyCustomizing-XL maximal 550 data points, maximum 100 individual designed views EasyCustomizing-XXL maximal 1000 data points, maximum 100 individual designed views 262 Product Catalogue EM

119 Software Cost center handling software EMIS Report Cost Center Handling Software Cost Center Handling Software with EMIS Report Cost Center Handling Software with EMIS Report. Description The consumption data acquired by the FRAKO Energy Management System can be read to an Excel workbook from the SQL databases FRAKO-NET DB or FRAKO EMIS-DB. The period covered by the evaluation can be selected as desired. Individual loads or metering units can be combined into load groups or cost centres and evaluated according to differing time schedules. Customer-specific reports are easy to create by selecting appropriate cells. This achieves optimized transparency for the utility flows within the company. With EMIS report, data from the FRAKO data base can be read out in an excel-file and are herewith available for a customer specific analysis. A useful tool for the allocation of costs for each divisions or purchaser and for the controlling of a company. Utility cost transparency. Assigning costs to the originators Accurate classification of the costs of providing capacity Transparency of all utility flows in the company Achievement of the best possible cost-effectiveness Automatic evaluation with notification by , as CSV file if required An optimized reduction of utility costs is only possible if the information is available on how much energy is being used when and where. The knowledge of the utility consumption of individual cost centres is a prerequisite for determining and implementing potential cost-cutting measures. EMIS Report provides you with a structured overview of the consumption of all utilities in your company, such as power, water, gas, compressed air, etc., so that you can make a financial analysis of these figures. Individual loads or metering units can be combined into load groups or cost centres and evaluated according to differing time schedules. Product Catalogue EM 263

120 This achieves optimized transparency for the utility flows within the company. Functions: Automatic evaluation with notification by Period covered by the report can be defined at will (date, day, etc.) Determination of consumption(kwh, l, m 3, etc.) Consumption peaks within the reporting period Times at which peak consumption occurs Demand by a load or a load group at the time of the peak consumption of a reference unit Interval figures (e.g. 15 minutes) in the reporting period for consumption or utility demand Sum of the interval figures in the report period Evaluation according to differing time profiles Technical data PC-requirements Hardware Software Pentium, min. 2 GHz clock frequency min. 1 GB working memory 6 GB free hard disk memory Ethernet 10/100 MB network connection or/and one free serial interface CD-ROM-drive SVGA-graphic card Colour screen, minimum resolution: 1024 x 768 Pixel Database FRAKO-NET DB or FRAKO EMIS-DB Windows 2000 pro (min. SP3) Windows XP pro (min. SP1) Windows 2003 Server (min. SP1) Internet Explorer 5.5 Excel (from Version 2000) * registered trademarks of Microsoft Coorporation Article-No Optional accessory Type Description Article-No. Softwareexpansion for EMIS Report Software-Update for cost centers and analysis software EMIS Report 264 Product Catalogue EM

121 Software EMG-OPC-Server EMG-OPC-Server Software interface for the current OPC-Server. Description Software interface to exchange online values of max data points based on the OPC specifications 1.0, 2.0 and 3.0. Communication via TCP/IP network with max. 8 FRAKO devices e,g.: Gateway EMG 1500-PN Central Unit EMIS 1500 Maximum Controller EM-MC 2200 Power Quality Analyzer EM-PQ 2300 Technical data PC-requirements for small and medium systems Hardware - 2 GHz Prozessor Dual Core - 2 GB RAM - 1 GB of free disk space - Ethernet 10/100 MB network connection Software Operating system: - Windows XP SP3 - Windows 7 (x32/x64) - Windows Server (2003 R2 / 2008 R2) - Windows DOT NET 4.0 Client oder FULL Article-No Product Catalogue EM 265

Mains Monitoring Instruments 4

Mains Monitoring Instruments 4 The power quality of the electrical supply networks plays an increasingly important role for the operational safety of electrical installations and equipment. Therefore it becomes more and more important

More information

EMIS Central Unit. System Components. Central Unit

EMIS Central Unit. System Components. Central Unit System Components Central Unit 1 EMIS 1500 Central Unit A network-compatible central unit for data acquisition and data management of the Energy Management devices connected. Description The well-established

More information

PQM 1588 Power Quality Manager

PQM 1588 Power Quality Manager System Components Central Units 1 PQM 1588 Power Quality Manager The Power Quality Manager is used to provide and record data from the Power Quality Management System. Furthermore alarms are detected,

More information

PQM 1588 Power Quality Manager

PQM 1588 Power Quality Manager System Components Central Unit 1 PQM 1588 Power Quality Manager The Power Quality Manager is used to provide and record data from the Power Quality Management System. Furthermore alarms are detected, recorded

More information

PQM - Power Quality Monitoring

PQM - Power Quality Monitoring UMG 511 PQM - Power Quality Monitoring Class A power quality analyser according to IEC61000-4-30 The UMG 511 power quality analyser is particularly suitable for monitoring power quality according to standards

More information

UMG 511. Class A EN UMG 511 Class A power quality analyzer. according to EN50160, IEEE 519, ITIC, IEC Areas of application

UMG 511. Class A EN UMG 511 Class A power quality analyzer. according to EN50160, IEEE 519, ITIC, IEC Areas of application UMG 511 Class A EN 50160 UMG 511 Class A power quality analyzer according to EN50160, IEEE 519, ITIC, IEC 61000-4-30 The UMG 511 power quality analyzer is particularly suitable for monitoring power quality

More information

UMG 605. UMG 605 power quality analyzer (EN 50160, IEEE 519, ITIC)

UMG 605. UMG 605 power quality analyzer (EN 50160, IEEE 519, ITIC) UMG 605 UMG 605 power quality analyzer (EN 50160, IEEE 519, ITIC) The UMG 605 power quality analyzer is particularly suitable for monitoring power quality according to standards such as EN 50160. All power

More information

UMG 604. UMG 604 Power analyser. Modbus master, Ethernet gateway. Harmonics. Memory 128 MByte. Homepage. Graphic programming.

UMG 604. UMG 604 Power analyser. Modbus master, Ethernet gateway. Harmonics. Memory 128 MByte. Homepage. Graphic programming. Harmonics Modbus master, Ethernet gateway Memory 128 MByte Homepage Events Graphic programming UMG 604 Power analyser Communication Profibus (DP/ V0) Modbus (RTU, UDP, TCP, Gateway) TCP/IP BACnet (optional)

More information

Networks TN, TT, IT networks 3 and 4-phase networks Up to 4 single-phase networks

Networks TN, TT, IT networks 3 and 4-phase networks Up to 4 single-phase networks Memory 256 MB 8 Tariffs Harmonics Pulse inputs and outputs Measurement accuracy 0.5 UMG 96RM Multifunction power analyser Communication (device-specific) Modbus (RTU) Profibus DP V0 Profinet TCP/IP M-Bus

More information

PQM - Power Quality Monitoring

PQM - Power Quality Monitoring UMG 507 PQM - Power Quality Monitoring Continuous measurements and the Ethernet Power analysers of the UMG 507 product family are suitable for use at all network levels. The continuous measurement enables

More information

Smart Energy & Power Quality Solutions. UMG 507 Power analyser

Smart Energy & Power Quality Solutions. UMG 507 Power analyser Smart Energy & Power Quality Solutions UMG 507 Power analyser UMG 507 UMG 507 Power analyser Power analysers of the UMG 507 product family are suitable for use at all network levels. The continuous measurement

More information

Setting up an EM System

Setting up an EM System Energy Management System Operating Instructions Setting up an EM System Safety and Warning Instructions EM System Operating Instructions Safety and Warning Instructions!!! Important: read before commissoning!!!

More information

PQM - Power Quality Monitoring

PQM - Power Quality Monitoring UMG 604 PQM - Power Quality Monitoring High performance power analysers for DIN rails High performance power analysers from the UMG 604 product family are suitable for use at all network levels. The high

More information

PM174 PM174 IEEE1159 ADVANCED POWER QUALITY ANALYZER. Features

PM174 PM174 IEEE1159 ADVANCED POWER QUALITY ANALYZER. Features PM174 IEEE1159 ADVANCED POWER QUALITY ANALYZER The PM174 is a compact, multi-function, three-phase AC powermeter and power quality analyzer specially designed to meet the requirements of users ranging

More information

UMG 605. UMG 605 Power quality analysers for DIN rails. Flicker. Reporting. Memory 128 MByte.

UMG 605. UMG 605 Power quality analysers for DIN rails. Flicker. Reporting. Memory 128 MByte. Harmonics Alarm management Flicker Reporting Email Memory 128 MByte Power quality analysers for DIN rails Communication Profibus (DP / V0) Modbus (RTU, UDP, TCP, Gateway) TCP/IP BACnet (optional) HTTP

More information

UMG 96RM. UMG 96RM Universal measurement instrument. Areas of application

UMG 96RM. UMG 96RM Universal measurement instrument. Areas of application UMG 96RM UMG 96RM Universal measurement instrument The UMG 96RM is a very compact and powerful universal measurement device designed for use in low and medium voltage distribution systems. In addition

More information

DATA SHEET LAN Server For Energy and Power meters AEM and APM with Modbus interface

DATA SHEET LAN Server For Energy and Power meters AEM and APM with Modbus interface DATA SHEET For Energy and Power meters AEM and APM with Modbus interface Data logging Web Server interface Gateway - Modbus TCP/IP FTP DynDNS Up to 32 Energy and Power meters DEIF A/S Page 1 of 9 Document

More information

POWER SIMPLY SAVE. Catalogue Catalogue 2017

POWER SIMPLY SAVE. Catalogue Catalogue 2017 Smart Energy & Power Quality Solutions Smart Energy & Power Quality Solutions Catalogue 2017 Catalogue 2017 Janitza electronics GmbH Vor dem Polstück 6 35633 Lahnau Deutschland Tel.: +49 6441 9642-0 Fax:

More information

MIC-2 Multi-instrument DATA SHEET

MIC-2 Multi-instrument DATA SHEET Measurements All 3-phase AC measurements True RMS 4-Quadrant energy Power Quality Analysis Replaces analogue meters RS-485 Modbus RTU protocol TCP/IP Modbus (optional) Profibus DP (optional) I/O modules

More information

Smart Energy & Power Quality Solutions. UMG 505 Power analysis, LON and I/O-Vielfalt

Smart Energy & Power Quality Solutions. UMG 505 Power analysis, LON and I/O-Vielfalt Smart Energy & Power Quality Solutions UMG 505 Power analysis, LON and I/O-Vielfalt UMG 505 UMG 505 Power analysis, LON and I/O-Vielfalt Power analysers of the UMG505 product family are mainly designed

More information

OHIO SEMITRONICS, INC. AC MULTIFUNCTION PROGRAMMABLE TRANSDUCERS & -1000L

OHIO SEMITRONICS, INC. AC MULTIFUNCTION PROGRAMMABLE TRANSDUCERS & -1000L AC PROGRAMMABLE TRANSDUCERS MODBUS OR LONWORKS DESCRIPTION The DMT-1000 is a programmable transducer with an RS-485 bus interface (MODBUS ). It supervises several variables of a poly-phase electrical power

More information

MIC-2 MKII & MIC-2 MKII DIN, Multi-instrument DATA SHEET

MIC-2 MKII & MIC-2 MKII DIN, Multi-instrument DATA SHEET & DIN, Multi-instrument DATA SHEET Measurements All 3-phase AC measurements True RMS 4-Quadrant energy Power Quality Analysis Replaces analogue meters RS-485 Modbus RTU protocol TCP/IP Modbus (optional)

More information

UMG 20CM. 20 Channel Branch Circuit Monitoring Device with RCM

UMG 20CM. 20 Channel Branch Circuit Monitoring Device with RCM 20 Channel Branch Circuit Monitoring Device with RCM RCM Harmonics via analysis channel Alarm management GridVis Analysis software 20 current channels Interfaces / communication RS485 RTU Accuracy of measurement

More information

PLC PFC200 Controller PFC200 CS 2ETH RS

PLC PFC200 Controller PFC200 CS 2ETH RS 0-202 PLC PFC200 Controller PFC200 CS 2ETH RS Marking area Serial interface RJ-4 RJ-4 ACT X2 LNK ETH ACT X LNK X3 RS232/4 U U U4 U3 U2 U STOP RESET 0-202 SYS I/O MS NS U RST SD 0 02 A B 24V 0V + + Status

More information

with Backlight Graphic LCD Screen

with Backlight Graphic LCD Screen with Backlight Graphic LCD Screen ENERGY AND AUTOMATION POWER OF ENERGY SAVING For the control of energy distribution systems detecting when problems occur that could put the quality and availability of

More information

MIC-2 MKII, Multi-instrument DATA SHEET

MIC-2 MKII, Multi-instrument DATA SHEET MIC-2 MKII, Multi-instrument DATA SHEET Measurements All 3-phase AC measurements True RMS 4-Quadrant energy Power Quality Analysis Replaces analogue meters RS-485 Modbus RTU protocol TCP/IP Modbus (optional)

More information

U niversal Measuring Device UMG 96 S. Little Fieldbus Giant. Modbus / Profibus. Harmonics. Memory. Analogue outputs. Digital I/O

U niversal Measuring Device UMG 96 S. Little Fieldbus Giant. Modbus / Profibus. Harmonics. Memory. Analogue outputs. Digital I/O U niversal Measuring Device Little Fieldbus Giant Modbus / Profibus Harmonics Memory Analogue outputs Digital I/O Modem Recorder Profibus Modbus PC I/O Universal Measuring Device Application Application

More information

Dupline. Data Logger. Types G , G Product Description. Ordering Key G Type Selection. Input/Output Specifications

Dupline. Data Logger. Types G , G Product Description. Ordering Key G Type Selection. Input/Output Specifications Dupline Data Logger Types G 800 006, G 800 106 Product Description Programmable channel generator with optional built-in GSM Modem Event and time based data logging functions for digital, analog and counter

More information

Smart Energy & Power Quality Solutions. ProData datalogger. Datalogger and Gateway

Smart Energy & Power Quality Solutions. ProData datalogger. Datalogger and Gateway Smart Energy & Power Quality Solutions ProData datalogger Datalogger and Gateway Smart and compact: Our most universal datalogger ever saves power costs Ethernet connection Modbus-Ethernet-Gateway 32 MB

More information

XPSMF35. Product data sheet Characteristics. Preventa safety PLC compact - Profibus DP protocol. Main. Complementary. Safety module name

XPSMF35. Product data sheet Characteristics. Preventa safety PLC compact - Profibus DP protocol. Main. Complementary. Safety module name Product data sheet Characteristics XPSMF3542 Preventa safety PLC compact - Profibus DP protocol Main Range of product Product or component type Safety module name Safety module application Nov 13, 2018

More information

Power and accuracy. Versatile. One display can monitor up to 32 measuring modules information

Power and accuracy. Versatile. One display can monitor up to 32 measuring modules information Power and accuracy 0.2% or 0.5% class in power and active energy measurement Over 500 electric parameters display Both voltage and current harmonics spectrum graphics (to the 50 th ) Maximum and minimum

More information

PQM - Power Quality Monitoring

PQM - Power Quality Monitoring UMG 96S PQM - Power Quality Monitoring The little field bus giant Universal flush-mounting measuring instruments of the UMG 96S product family are mainly designed for use in low and medium voltage distribution

More information

6-Channel power analyser UMG 96RM-E. Operating current and RCM fault current monitoring. Smart Energy & Power Quality Solutions RCM.

6-Channel power analyser UMG 96RM-E. Operating current and RCM fault current monitoring. Smart Energy & Power Quality Solutions RCM. Smart Energy & Power Quality Solutions Memory 256 MB RCM Ethernet-Modbus-Gateway Alarm management Homepage BACnet (optional) Operating current and RCM fault current monitoring The with 6 current channels

More information

FLEXIBLE SOLUTIONS FOR THE ENERGY INDUSTRY

FLEXIBLE SOLUTIONS FOR THE ENERGY INDUSTRY FLEXIBLE SOLUTIONS FOR THE ENERGY INDUSTRY COMPREHENSIVE INSTRUMENT FOR MEASUREMENT AND CONTROL OF POWER SYSTEMS CENTRAX CU-SERIES CENTRAX CU3000 CENTRAX CU5000 PAGE 2 Comprehensive instrument for measurement

More information

UMG 511. Class A power quality analyser. Reporting Homepage

UMG 511. Class A power quality analyser. Reporting Homepage Class A power quality analyser Class A Flicker Reporting Homepage Harmonics Alarm management Communication Profibus (DP/V0) Modbus (RTU, TCP, Gateway) TCP/IP BACnet (optional) HTTP (configurable homepage)

More information

ProData DATA LOGGER. Chapter 03 ProData data logger. Ethernet. Pulse inputs and Pulse outputs. Modbus-Ethernet gateway. Thermistor input.

ProData DATA LOGGER. Chapter 03 ProData data logger. Ethernet. Pulse inputs and Pulse outputs. Modbus-Ethernet gateway. Thermistor input. ProData DATA LOGGER Ethernet Pulse inputs and Pulse outputs Modbus-Ethernet gateway Thermistor input Memory 32 MB Threshold value monitoring 139 Smart and compact: Save energy costs through the universal

More information

ProData data logger. Ethernet. Pulse inputs and Pulse outputs. Thermistor input. Modbus-Ethernet gateway. Memory 32 MB. Threshold value monitoring

ProData data logger. Ethernet. Pulse inputs and Pulse outputs. Thermistor input. Modbus-Ethernet gateway. Memory 32 MB. Threshold value monitoring Ethernet Pulse inputs and Pulse outputs Modbus-Ethernet gateway Thermistor input Memory 32 MB Threshold value monitoring ProData data logger 1 Smart and compact: Save energy costs through the universal

More information

DIRIS Digiware D and C Communication and control power interfaces

DIRIS Digiware D and C Communication and control power interfaces Multi-circuit metering and measurement diris-dw_006_a_us_cat diris-dw_142_a The solution for > Industry > Building > Infrastructure > Data centers DIRIS D-40/D-50/D-70 Centralization and display of data

More information

Increase transparency and process quality Total Energy Monitoring across all levels of production Let s connect. Measuring and monitoring systems

Increase transparency and process quality Total Energy Monitoring across all levels of production Let s connect. Measuring and monitoring systems Increase transparency and process quality Total Energy Monitoring across all levels of production Let s connect. Measuring and monitoring systems Energy monitoring Quick selection guide Energy meters product

More information

FOUR FUNCTIONS ONE SOLUTION

FOUR FUNCTIONS ONE SOLUTION 4-IN-1 FOUR FUNCTIONS ONE SOLUTION MID ENERGY MEASUREMENT DEVICE 4-in-1: Energy management, MID, power quality monitoring and RCM monitoring Intuitive user guidance High quality colour graphics display

More information

UMG 20CM. UMG 20CM 20 Channel Branch Circuit Monitoring Device with RCM. Harmonics via analysis channel RCM. Alarm management.

UMG 20CM. UMG 20CM 20 Channel Branch Circuit Monitoring Device with RCM. Harmonics via analysis channel RCM. Alarm management. RCM Harmonics via analysis channel Alarm management GridVis Analysis software 20 current channels 20 Channel Branch Circuit Monitoring Device with RCM Interfaces / communication RS485 RTU Accuracy of measurement

More information

A NEW DATA LOGGER Stand alone. Secure. Fast.

A NEW DATA LOGGER Stand alone. Secure. Fast. A NEW DATA LOGGER Stand alone. Secure. Fast. A data logger for profe Extensive functions LogMessage data loggers are universal. Whatever the application for slow or for high-speed acquisition Delphin has

More information

DS 500 Intelligent chart recorder for compressed air and gases

DS 500 Intelligent chart recorder for compressed air and gases DS 500 Intelligent chart recorder for compressed air and gases Measurement - control - indication - alarm - recording - evaluation Advantages at a glance: Clear layout: 7 colour screen with touch panel...

More information

Network Components. Network Components 8

Network Components. Network Components 8 77 PSTN Router Managed Switches Unmanaged Switches Hubs Micro Transceiver Media Converter Network Adapter Ethernet Cable Network Accessories 7 for S7 S5 General Internet Modem Access Router Gateway analog

More information

Smart Energy & Power Quality Solutions. UMG 96S Universal flush-mounting measuring instrument

Smart Energy & Power Quality Solutions. UMG 96S Universal flush-mounting measuring instrument Smart Energy & Power Quality Solutions UMG 96S Universal flush-mounting measuring instrument UMG 96S UMG 96S Universal flushmounting measuring instrument Universal flush-mounting measuring instruments

More information

VersaMax Micro and Nano Technical Product Presentation

VersaMax Micro and Nano Technical Product Presentation VersaMax Nano VersaMax Micro VersaMax Micro and Nano Technical Product Presentation Outline Introduction VersaMax Micro and Nano Product Strategy Future Products Product Description VersaMax Nano VersaMax

More information

General information. Display. Supply voltage

General information. Display. Supply voltage Data sheet SIMATIC S7-1200, CPU 1212C, COMPACT CPU, DC/DC/RLY, ONBOARD I/O: 8 DI 24V DC; 6 DO RELAY 2A; 2 AI 0-10V DC, POWER SUPPLY: DC 20.4-28.8 V DC, PROGRAM/DATA MEMORY: 75 KB General information Product

More information

COMTRAXX COM460IP. BMS-Ethernet-Gateway

COMTRAXX COM460IP. BMS-Ethernet-Gateway COMTRAXX COM460IP BMS-Ethernet-Gateway COM460IP_D00023_03_D_XXEN/11.2015 COMTRAXX COM460IP BMS-Ethernet-Gateway COM460IP Device features Modular, expandable gateway between BMS bus and TCP/IP Gateway between

More information

IDM DATA ACQUISITION SYSTEM

IDM DATA ACQUISITION SYSTEM DATA ACQUISITION SYSTEM The a compact and economical multifunction data acquisition system Rendering all Unrivalled product profile Advanced multifunctional distributed data acquisition system Fully multitasking

More information

U niversal Measuring Device NEW! UMG 96 S. Little Fieldbus Giant. Modbus / Profibus. Harmonics. Memory. Analogue outputs.

U niversal Measuring Device NEW! UMG 96 S. Little Fieldbus Giant. Modbus / Profibus. Harmonics. Memory. Analogue outputs. U niversal Measuring Device NEW! Little Fieldbus Giant Modbus / Profibus Harmonics Memory Analogue outputs Digital I/O Modem Recorder Profibus Modbus PC I/O Universal Measuring Device Application Application

More information

General information. Display. Supply voltage

General information. Display. Supply voltage Data sheet SIMATIC S7-1200, CPU 1211C, COMPACT CPU, DC/DC/DC, ONBOARD I/O: 6 DI 24V DC; 4 DO 24 V DC; 2 AI 0-10V DC, POWER SUPPLY: DC 20.4-28.8 V DC, PROGRAM/DATA MEMORY: 50 KB General information Product

More information

A2000 Multifunctional Power Meter

A2000 Multifunctional Power Meter 3-348-980-03 3/12.99 Capable of communications via Profibus-DP, LONWORKS interface or RS 485 interface (depending upon model) Measurement of current, voltage, active, reactive and apparent power, power

More information

TFS 2100 Traveling Wave Fault Location System

TFS 2100 Traveling Wave Fault Location System Traveling Wave Fault Location System The most accurate overhead transmission and distribution line fault locator Accuracy: ±150m typical regardless the line length Unaffected by fault resistance Suitable

More information

General information. Display. Supply voltage. Input current

General information. Display. Supply voltage. Input current Data sheet SIMATIC S7-1200, CPU 1215C, COMPACT CPU, AC/DC/RELAY, 2 PROFINET PORT, ONBOARD I/O: 14 DI 24V DC; 10 DO RELAY 2A, 2 AI 0-10V DC, 2 AO 0-20MA DC, POWER SUPPLY: AC 85-264 V AC AT 47-63 HZ, PROGRAM/DATA

More information

Fieldgate SFG500. Technical Information. Intelligent Ethernet/PROFIBUS gateway

Fieldgate SFG500. Technical Information. Intelligent Ethernet/PROFIBUS gateway Technical Information Fieldgate Intelligent Ethernet/PROFIBUS gateway Application Fieldgate is a system component that provides an independent access route to a PROFIBUS network. It may be used in a variety

More information

General information. Display. Supply voltage. Input current

General information. Display. Supply voltage. Input current Data sheet SIMATIC S7-1200, CPU 1214C, COMPACT CPU, DC/DC/DC, ONBOARD I/O: 14 DI 24V DC; 10 DO 24 V DC; 2 AI 0-10V DC, POWER SUPPLY: DC 20.4-28.8 V DC, PROGRAM/DATA MEMORY: 100 KB General information Firmware

More information

DIRIS A-30 Multifunction power metering & monitoring device - PMD

DIRIS A-30 Multifunction power metering & monitoring device - PMD Single-circuit metering, measurement & analysis The solution for > Industry > Building > Infrastructures diris_986_a_us.psd Strong points Function The is a power metering and monitoring device that provides

More information

PEAK TM. PEAK TM controllers. Mid-Market BAS Smart equipment controllers. HVAC/R controllers

PEAK TM. PEAK TM controllers. Mid-Market BAS Smart equipment controllers. HVAC/R controllers Virtual Branch ecatalogue click here controllers HVAC/R controllers The PEAK 18 and PEAK 32 Controllers are configurable controllers that can be switched between MS/TP, Modbus RTU, and N2 Communication

More information

THE NEXT TRANSDUCER GENERATION

THE NEXT TRANSDUCER GENERATION THE NEXT TRANSDUCER GENERATION ADJUSTABLE HIGH-ACCURACY HEAVY-CURRENT SENSORS SINEAX DM5S/DM5F Heavy-current sensor for grid monitoring. SINEAX DM5S and SINEAX DM5F are freeprogrammable universal measurement

More information

General information. Display. Supply voltage. Input current. Encoder supply. Output current

General information. Display. Supply voltage. Input current. Encoder supply. Output current Data sheet SIMATIC S7-1200, CPU 1211C, COMPACT CPU, DC/DC/RELAY, ONBOARD I/O: 6 DI 24V DC; 4 DO RELAY 2A; 2 AI 0-10V DC, POWER SUPPLY: DC 20.4-28.8 V DC, PROGRAM/DATA MEMORY: 50 KB General information

More information

General information. Display. Supply voltage

General information. Display. Supply voltage Data sheet SIMATIC S7-1200, CPU 1211C, COMPACT CPU, DC/DC/RELAY, ONBOARD I/O: 6 DI 24V DC; 4 DO RELAY 2A; 2 AI 0-10V DC, POWER SUPPLY: DC 20.4-28.8 V DC, PROGRAM/DATA MEMORY: 50 KB General information

More information

General information. Display. Supply voltage. Input current. Encoder supply. Output current

General information. Display. Supply voltage. Input current. Encoder supply. Output current Data sheet SIMATIC S7-1200, CPU 1211C, COMPACT CPU, DC/DC/RELAY, ONBOARD I/O: 6 DI 24V DC; 4 DO RELAY 2A; 2 AI 0-10V DC, POWER SUPPLY: DC 20.4-28.8 V DC, PROGRAM/DATA MEMORY: 50 KB General information

More information

Multifunction Transducer MT440

Multifunction Transducer MT440 Multifunction Transducer MT440 Voltage and current auto range measurements up to 600V, 12.5A Universal wide auxiliary power supply range 24 300 Vdc, 40 276 Vac Power accuracy class 0.5 (EN 60 688), Up

More information

General information. Display. Supply voltage. Input current. Encoder supply. Output current

General information. Display. Supply voltage. Input current. Encoder supply. Output current Data sheet SIMATIC S7-1200, CPU 1214C, COMPACT CPU, DC/DC/RELAY, ONBOARD I/O: 14 DI 24V DC; 10 DO RELAY 2A; 2 AI 0-10V DC, POWER SUPPLY: DC 20.4-28.8 V DC, PROGRAM/DATA MEMORY: 75 KB General information

More information

DEIF A/S. MIC Multi-instrument G. Data sheet. Features. Accuracy. Measurements. Installation. Intelligent. Display. Communication DEIF A/S

DEIF A/S. MIC Multi-instrument G. Data sheet. Features. Accuracy. Measurements. Installation. Intelligent. Display. Communication DEIF A/S Multi-instrument 4921210107G Features Measurements All 3-phase AC measurements True RMS Replaces analogue meters Intelligent Suitable for all 3-phase network topologies Replaces transducers Accuracy U,

More information

BMS-Ethernet-Gateway COM460IP

BMS-Ethernet-Gateway COM460IP BMS-Ethernet-Gateway TDB501015en / 11.2012 BMS-Ethernet-Gateway BMS-Ethernet-Gateway Device features Modular, expandable gateway between BMS bus and TCP/IP Gateway between BMS bus and Ethernet Range of

More information

General information. Display. Supply voltage. Input current. Encoder supply. Output current

General information. Display. Supply voltage. Input current. Encoder supply. Output current Data sheet SIMATIC S7-1200, CPU 1211C, COMPACT CPU, AC/DC/RELAY, ONBOARD I/O: 6 DI 24V DC; 4 DO RELAY 2A; 2 AI 0-10V DC, POWER SUPPLY: AC 85-264 V AC AT 47-63 HZ, PROGRAM/DATA MEMORY: 50 KB General information

More information

General information. Display. Supply voltage. Input current

General information. Display. Supply voltage. Input current Data sheet SIMATIC S7-1200F, CPU 1215 FC, COMPACT CPU, DC/DC/DC, 2 PROFINET PORT, ONBOARD I/O: 14 DI 24VDC; 10 DO 24V DC 0.5A; 2 AI 0-10V DC, 2 AO 0-20MA DC, POWER SUPPLY: DC 20.4-28.8 V DC, PROGRAM/DATA

More information

General information. Display. Supply voltage. Input current. Encoder supply. Output current

General information. Display. Supply voltage. Input current. Encoder supply. Output current Data sheet SIMATIC S7-1200, CPU 1214C, COMPACT CPU, DC/DC/DC, ONBOARD I/O: 14 DI 24V DC; 10 DO 24 V DC; 2 AI 0-10V DC, POWER SUPPLY: DC 20.4-28.8 V DC, PROGRAM/DATA MEMORY: 75 KB General information Engineering

More information

General information. Display. Supply voltage. Input current. Encoder supply. Output current

General information. Display. Supply voltage. Input current. Encoder supply. Output current Data sheet SIMATIC S7-1200, CPU 1215C, COMPACT CPU, DC/DC/DC, 2 PROFINET PORT, ONBOARD I/O: 14 DI 24V DC; 10 DO 24V DC 0.5A 2 AI 0-10V DC, 2 AO 0-20MA DC, POWER SUPPLY: DC 20.4-28.8 V DC, PROGRAM/DATA

More information

General information. Display. Supply voltage. Input current

General information. Display. Supply voltage. Input current Data sheet SIMATIC S7-1200, CPU 1215C, COMPACT CPU, DC/DC/DC, 2 PROFINET PORT, ONBOARD I/O: 14 DI 24V DC; 10 DO 24V DC 0.5A 2 AI 0-10V DC, 2 AO 0-20MA DC, POWER SUPPLY: DC 20.4-28.8 V DC, PROGRAM/DATA

More information

General information. Display. Supply voltage. Input current. Encoder supply. Output current. Power loss. Memory

General information. Display. Supply voltage. Input current. Encoder supply. Output current. Power loss. Memory Data sheet SIPLUS S7-1200 CPU 1214C DC/DC/DC -40...+70 DEGREES C WITH CONFORMAL COATING BASED ON 6ES7214-1AG40-0XB0. COMPACT CPU, DC/DC/DC, ONBOARD I/O: 14 DI 24V DC 10 DO 24 V DC 2 AI 0-10V DC, POWER

More information

Display. Supply voltage. Input current. Encoder supply. Output current. Power losses. Memory

Display. Supply voltage. Input current. Encoder supply. Output current. Power losses. Memory Datasheet SIMATIC S7-1200, CPU 1214C, COMPACT CPU, AC/DC/RLY, ONBOARD I/O: 14 DI 24V DC; 10 DO RELAY 2A; 2 AI 0-10V DC, POWER SUPPLY: AC 85-264 V AC AT 47-63 HZ, PROGRAM/DATA MEMORY: 75 KB Display with

More information

clarity 3 Programmable Controller

clarity 3 Programmable Controller clarity 3 Programmable Controller BACnet General Purpose Controllers (B-AAC) DESCRIPTION Taco Clarity 3 FPC series controllers are designed to control building systems and HVAC equipment. The integrated

More information

Data sheet CPU 013C (013-CCF0R00)

Data sheet CPU 013C (013-CCF0R00) Data sheet CPU 013C (013-CCF0R00) Technical data Order no. 013-CCF0R00 Type CPU 013C Module ID - General information Note - Features Technical data power supply Power supply (rated value) Power supply

More information

COMTRAXX COM465DP. Condition Monitor with integrated gateway for the connection of Bender devices to PROFIBUS DP and Ethernet TCP/IP networks

COMTRAXX COM465DP. Condition Monitor with integrated gateway for the connection of Bender devices to PROFIBUS DP and Ethernet TCP/IP networks Condition Monitor with integrated gateway for the connection of Bender devices to PROFIBUS DP and Ethernet TCP/IP networks COM465DP_D00216_00_D_XXDE/10.2015 Condition Monitor with integrated gateway for

More information

Energy Management Solutions

Energy Management Solutions Energy Management Solutions Power Generation and Transmission Facilities You can provide solution in your Power transmission project with Klea Energy Analyser and Systemon Software Shopping Malls and Chain

More information

KS 3012 PMA GENERAL DESCRIPTION

KS 3012 PMA GENERAL DESCRIPTION PMA KS 301 6 / 1 universal inputs 7 digital inputs Data acquisition with a sampling rate of 15 ms CF card as data storage medium Use as point or line recorder Visualization in up to 6 groups Modbus interface

More information

EM132 EM132. Main Features. Multi-functional 3-Phase Transducer. Energy Meter

EM132 EM132. Main Features. Multi-functional 3-Phase Transducer. Energy Meter EM132 MULTI-FUNCTION TRANSDUCER SATEC EM132 is a Smart DIN Rail Multi-Function Transducer with a local display. It is based on SATEC s best seller PM130 PLUS with an off-the-shelf LCD display (similar

More information

XPSMF40. Main. Safety module name. Monitoring safety detection discrete input Monitoring safety dialogue discrete output

XPSMF40. Main. Safety module name. Monitoring safety detection discrete input Monitoring safety dialogue discrete output Product datasheet Characteristics XPSMF4000 Preventa safety PLC compact - Safe Ethernet Main Range of product Product or component type Safety module name Safety module application Preventa Safety automation

More information

Display. Supply voltage. Input current. Encoder supply. Output current. Power losses. Memory

Display. Supply voltage. Input current. Encoder supply. Output current. Power losses. Memory Datasheet SIMATIC S7-1200, CPU 1214C, COMPACT CPU, DC/DC/DC, ONBOARD I/O: 14 DI 24V DC; 10 DO 24 V DC; 2 AI 0-10V DC, POWER SUPPLY: DC 20.4-28.8 V DC, PROGRAM/DATA MEMORY: 75 KB Display with display Supply

More information

MXPLC. Compact PLC process station. Summary. Application HVAC control systems, data acquisition, interfacing 3 rd party systems.

MXPLC. Compact PLC process station. Summary. Application HVAC control systems, data acquisition, interfacing 3 rd party systems. MXPLC Compact PLC process station Summary The MXPLC is a programmable process station with integrated I/O module with the I/O mix optimized for larger HVAC control applications. The multi-interface process

More information

General information. Display. Supply voltage. Input current

General information. Display. Supply voltage. Input current Data sheet SIMATIC S7-1200F, CPU 1214 FC, COMPACT CPU, DC/DC/DC, ONBOARD I/O: 14 DI 24V DC; 10 DO 24 V DC; 2 AI 0-10V DC, POWER SUPPLY: DC 20.4-28.8 V DC, PROGRAM/DATA MEMORY 125 KB General information

More information

General information. Supply voltage. Input current. Encoder supply. Power loss. Memory

General information. Supply voltage. Input current. Encoder supply. Power loss. Memory Data sheet SIMATIC S7-1200, CPU 1215C, COMPACT CPU, AC/DC/RELAY, 2 PROFINET PORT, ONBOARD I/O: 14 DI 24V DC; 10 DO RELAY 2A, 2 AI 0-10V DC, 2 AO 0-20MA DC, POWER SUPPLY: AC 85-264 V AC AT 47-63 HZ, PROGRAM/DATA

More information

PBSCONTROL. AMS-R4000 Modular RTU. Remote Terminal Unit

PBSCONTROL. AMS-R4000 Modular RTU. Remote Terminal Unit PBSCONTROL AMS-R4000 Modular RTU Remote Terminal Unit AMS-R4000 Introduction The documentation and the software included with this product are copyrighted 2017 by pbscontrol Company. AMS-4000 System is

More information

ELR W1/ 6-24DC. Extract from the online catalog. Order No.:

ELR W1/ 6-24DC. Extract from the online catalog. Order No.: Extract from the online catalog ELR W1/ 6-24DC Order No.: 2982090 Illustration shows item ELR W1/ 6-24DC Electronic reversing load relay, for driving DC motors, with light indicator and protection circuit,

More information

Data Sheet. Digital Multifunctional Power Meter with LCD Display and Optional Modules WPM D

Data Sheet. Digital Multifunctional Power Meter with LCD Display and Optional Modules WPM D WPM 770 Data Sheet 679.D.141.02 Digital Multifunctional Power Meter with LCD Display and Application The digital Weigel Power Meters WPM 770 have been designed to display the electrical parameters in low

More information

General information. Display. Supply voltage. Input current. Encoder supply. Power losses

General information. Display. Supply voltage. Input current. Encoder supply. Power losses Data sheet SIMATIC S7-1200, CPU 1215C, COMPACT CPU, DC/DC/RELAY, 2 PROFINET PORT, ONBOARD I/O: 14 DI 24V DC; 10 DO RELAY 2A, 2 AI 0-10V DC, 2 AO 0-20MA DC, POWER SUPPLY: DC 20.4-28.8 V DC, PROGRAM/DATA

More information

PQube 3. Power Quality, Energy & Environment Monitoring. New Low-Cost, High-Precision

PQube 3. Power Quality, Energy & Environment Monitoring. New Low-Cost, High-Precision Power Sensors Ltd New Low-Cost, High-Precision Power Quality, Energy & Environment Monitoring PQube 3 Power Quality Class A Edition 3 Energy Revenue Grade class 0.2/0.2s Accuracy Additional AC, DC, and

More information

General information Engineering with Programming package. Display with display. Supply voltage 24 V DC Yes

General information Engineering with Programming package. Display with display. Supply voltage 24 V DC Yes Datasheet SIMATIC S7-1200, CPU 1215C, COMPACT CPU, DC/DC/DC, 2 PROFINET PORT, ONBOARD I/O: 14 DI 24V DC; 10 DO 24V DC 0.5A 2 AI 0-10V DC, 2 AO 0-20MA DC, POWER SUPPLY: DC 20.4-28.8 V DC, PROGRAM/DATA MEMORY:

More information

JUMO mtron T. Measuring, Control, and Automation System. Features. Brief description. Systembus LAN. Data Sheet Page 1/12. Com1.

JUMO mtron T. Measuring, Control, and Automation System. Features. Brief description. Systembus LAN. Data Sheet Page 1/12. Com1. Data Sheet 705000 Page 1/12 JUMO mtron T Measuring, Control, and Automation System Com1 RS422/485 oder RS232, Modbus Master/Slave Com2 RS422/485 oder RS232, Modbus Master/Slave oder PROFIBUS-DP Slave LAN

More information

Modular Two-Wire Telecontrol System

Modular Two-Wire Telecontrol System Modular Two-Wire Telecontrol System Transmission via electrically isolated cables over distances up to 30 km Modular expansion up to 32 stations and a maximum of 512 I/O modules Easy parameterization of

More information

General information Engineering with Programming package. Display with display. Supply voltage 24 V DC Yes. Input current

General information Engineering with Programming package. Display with display. Supply voltage 24 V DC Yes. Input current Datasheet SIMATIC S7-1200, CPU 1214C, COMPACT CPU, DC/DC/DC, ONBOARD I/O: 14 DI 24V DC; 10 DO 24 V DC; 2 AI 0-10V DC, POWER SUPPLY: DC 20.4-28.8 V DC, PROGRAM/DATA MEMORY: 75 KB General information Engineering

More information

MPI-DN, MPI-D MULTICHANNEL ELECTRONIC RECORDER for HART or RS-485/ MODBUS RTU SENSORS

MPI-DN, MPI-D MULTICHANNEL ELECTRONIC RECORDER for HART or RS-485/ MODBUS RTU SENSORS MPI-DN, MPI-D MULTICHANNEL ELECTRONIC RECORDER for HART or RS-485/ MODBUS RTU SENSORS 18 channels for HART / Modbus RTU sensors 2 digital channels 16 math channels 4 relay outputs for alarm or control

More information

Functional data Position indication reflective visual indicator (snap on) Communicative control Cloud: (call for clientapi )

Functional data Position indication reflective visual indicator (snap on) Communicative control Cloud: (call for clientapi ) Technical data sheet AKRB24 IP Cloud capable and communicating valve actuator for adjusting flow in commercial HVAC applications. Failsafe Power Supply AC/DC 24 V Used for CCV and LGCCV assemblies. Ethernet

More information

mark150s mark150/485s DDC controllers Summary

mark150s mark150/485s DDC controllers Summary mark150s mark150/485s DDC controllers Summary DDC (Direct digital control) controller mark150s and mark150/485s are free programmable process stations with ARM Cortex M4 processor and OS FreeRTOS. They

More information

Transienten. Datenspeicher

Transienten. Datenspeicher 25. Grenzwertüberwachung Class A RCM Residual current monitoring Transienten Reporting Alarm management Harmonics Voltage quality Spannungsqualität Datenspeicher 32 MB 128 MB 256 MB 512 K Certificated

More information

RTU32S RTU32S Series Small Compact Utility RTU

RTU32S RTU32S Series Small Compact Utility RTU RTU32S RTU32S Series Small Compact Utility RTU Data Sheet 40270 v1.05 / July 7th, 2014 INTRODUCTION Brodersen Small Compact RTU32S Series with RTU/PLC functionality. The RTU32S series is based on an embedded

More information

TM221CE24R controller M IO relay Ethernet

TM221CE24R controller M IO relay Ethernet Product data sheet Characteristics TM221CE24R controller M221 24 IO relay Ethernet Complementary Main Discrete I/O number 24 Number of I/O expansion module Supply voltage limits Network frequency Inrush

More information

CoMo Logic. Electronics & Software. Single-Channel y(t) ControlMonitor. Type 5875A...

CoMo Logic. Electronics & Software. Single-Channel y(t) ControlMonitor. Type 5875A... Electronics & Software CoMo Logic Single-Channel y(t) ControlMonitor Type 5875A... The CoMo Logic monitor has a graphics display and charge mode input for monitoring time-dependent measurands in production