Raphael Monitoring Kit. Instruction Manual
|
|
- Annabel Jefferson
- 5 years ago
- Views:
Transcription
1 Raphael Monitoring Kit Instruction Manual
2 Raphael Monitoring Kit Copyright 2016 by Sper Scientific ALL RIGHTS RESERVED Printed in the USA The contents of this manual may not be reproduced or transmitted in any form or by any means electronic, mechanical, or other means that do not yet exist or may be developed, including photocopying, recording, or any information storage and retrieval system without the express permission from Sper Scientific. Sper Scientific 8281 E. Evans Rd., Suite #103, Scottsdale, AZ Tel: (480) Fax: (480) Web: FCC Notice Contains FCC ID: QIPPXS8 This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Compliance Information The Raphael device complies with the following radiated emission standards: ETSI EN Class B CFR 47 FCC Part 15 Subpart B Class B The Raphael device complies with Immunity per ETSI EN /-17 EN , 3, 4, 5, 6, RoHS, Directive 2002/95/EC,. 2
3 Contents Notices...2 Trademark Acknowledgments...2 FCC Notice...2 Compliance Information...2 Product Overview...4 Raphael Kits...5 Raphael Device...5 Turning the Raphael On...6 Sensor Integration...6 User Interface...7 Web-based Data Management System...8 Accessing the Data Management System...8 Understanding the Dashboard...8 Viewing Site Information...9 Understanding the Data Stream Chart...10 Comparing Data Streams...12 Generating Reports...13 Stream History Report...14 Aggregation Report...15 Daily Total Flow Report...16 Maintenance...17 Raphael Battery Replacement...17 Battery Replacement Instructions...17 Troubleshooting...19 Raphael Device Does not Turn On...19 Technical Support Contact Information...19 Glossary...19 Specifications...20 Raphael Specifications...20 Raphael Mechanical Drawings...22 Raphael Block Diagram...23 Warranty
4 PRODUCT OVERVIEW Sper Scientific s Raphael is a remote infrastructure monitoring tool that delivers field data to decision makers. It is an all inclusive, plug-and-play system, including batteries, SIM card, sensors, and installation hardware. After learning your specific needs, Sper Scientific pre-integrates the appropriate sensors with the Raphael data collection, storage and communication device which is then installed onto existing infrastructure. The data collected from the sensors is stored on Sper Scientific s secure private cloud server, and/or can be integrated directly into your onpremises servers. An Sper Scientific web-based data management system enables you to configure the device over-the-air and program various parameter threshold levels for and/or SMS alerts, visualize data in realtime, and produce reports for presentation and analysis. Using Sper Scientific s API, data can be integrated directly into your SCADA systems, business intelligence or other analytic software. Figure 1: Sper Scientific Raphael System 4
5 Raphael Kits Each Raphael Kit, composed of a Raphael device and smart sensors, is targeted at a specific phase in the water cycle. The intended usage dictates the type of sensors included in the kit. Sper Scientific offers the following types of kits: Water Kits: Water Supply Monitoring Kit Pump Station Monitoring Kit Reservoir & Tank Level Monitoring Kit Water Quality Monitoring Kit Wastewater Kits: Ultrasonic Combined Sewage Overflow Kit Hydrostatic Combined Sewage Overflow Kit Level Switch Combined Sewage Overflow Kit Discharge Monitoring Kit Wastewater Quality Monitoring Kit Environmental Kits: Precipitation Monitoring Kit Temperature Profile Monitoring Kit Groundwater Level Monitoring Kit Surface Water Level Monitoring Kit Optical Water Quality Monitoring Kit Raphael Device The Raphael device periodically samples the connected sensors and transmits the data to the Sper Scientific cloud or to your on-premises server. The device supports 2G, 3G and Verizon networks, and can interchangeably use the strongest available cellular signal. The Raphael device is powered by a fieldreplaceable internal battery that provides 3,500+ transmissions. Alternatively, the device can be connected to an external battery, solar panel, or permanent power source. The Raphael device can be mounted in any of the following ways: Affixed to a pipe, using the supplied zip ties. Affixed to a wall, using the supplied four screws and anchors Hung on a wall, using one of the supplied screws and anchors 5
6 Turning the Raphael On The Raphael device is delivered in hibernation mode. To turn it on, press the magnetic activator, provided in the Raphael Kit, onto the Raphael logo appearing on the Raphael device. The Raphael device turns on and performs a 10-minute calibration process, after which it starts operating in normal mode. Sensor Integration Each Raphael device has three sensor connector ports and supports any combination of the following types of sensors: Modbus Analog Digital Figure 2: Turning Raphael Device On The specific types of sensors and sensor connectors in a kit depend on the kit type. 6
7 User Interface The data collected by the Raphael device and transmitted to the Sper Scientific cloud can be viewed in the Sper Scientific web based data management system. The system enables: Visualizing data in real-time Generating reports for presentation and analysis Defining threshold levels for and/or SMS alerts for various parameters Over-the-air remote device configuration Receiving battery level notifications for predictive maintenance scheduling Figure 3: Web-based Data Management System 7
8 WEB-BASED DATA MANAGEMENT SYSTEM The Sper Scientific data management system provides the following: Dashboard window - for viewing your site deployment from the macro to the micro level Management window - for managing the Raphael devices and setting parameter thresholds Reports window - for generating reports and exporting them for viewing and sharing Accessing the Data Management System To access the Sper Scientific data management system: Navigate to.com, and enter your Sper Scientific credentials. Understanding the Sper Scientific Dashboard Click the Dashboard tab to display the initial Dashboard screen. Figure 4: Initial Dashboard Screen 8
9 The initial Dashboard screen is composed of a left pane and a right pane. Left pane - lists all Raphael sites and their data streams: Right pane - shows a zoomed-out map displaying clusters of data streams. Using the zoom controls, you can zoom in for greater detail, down to an individual site and its data streams. Viewing Site Information 1. To view the data from a specific Raphael site, click the site in the left pane or on the map. The right pane refreshes to show the site and its data streams. Figure 5: Viewing an Individual Site 9
10 2. To view the data sent from a specific data stream, click the data stream in the left pane or on the map. The right pane splits, displaying the data as a chart in the bottom half of the pane. Figure 6: Viewing an Individual Data Stream Understanding the Data Stream Chart Hovering over a point in the chart displays a tool tip with the following information: Timestamp Site name Type of data stream (such as Pressure, Level, etc.) The reading 10
11 Setting the Time Range You can set the start and end date for the chart by clicking the Range drop-down and setting the dates. Setting the Time Frame You can set the time frame shown in the window by selecting the desired time frame in the Time Frame selector. Using the Zoom and View tools You can adjust the view using any of the following tools, appearing to the right of the chart: Zoom to initial view (1 week) Pan left Pan right Zoom in Zoom out Download as.png. This opens the graph as a png file in a new browser tab. 11
12 Comparing Data Streams You can also compare the readings obtained from multiple data streams by displaying them in same chart. Up to five data streams of up to two different types can be displayed in the same chart. To compare data streams: 1. Double-click the first data stream in the left pane. The right pane splits, displaying the data in a chart in the bottom half of the pane. 2. Double-click the second data stream in the left pane. The data appears in the same chart in the bottom half of the right pane. 3. Repeat step (2) as desired. If you select more than five data streams in all, the data from the additional data streams will appear in a new tab. The following example shows a comparison of two Temperature data streams from the same site - one from a temperature sensor located at the bottom of a borehole, and one from a temperature sensor located at the top of the borehole. Figure 7: Comparing Two Data Streams 12
13 Generating Reports Using the Reports tab you can easily create various types of reports, and export them to Excel. Figure 8: Reports Tab You can create the following types of reports: Stream History Report Aggregation Report Daily Total Flow Report 13
14 Stream History Report This type of report displays the history of one or more data streams of a particular type. To create a Stream History report: 1. Select the stream type, the specific streams you wish to view, and the reporting time period. Figure 9: Stream History Report - Defining Report Criteria 2. Click Export to Excel. A CSV file is created, showing the history of the selected streams during the selected time period. Figure 10: Stream History Report - Example 14
15 Aggregation Report The Aggregation report enables viewing a statistical analysis of the readings obtained in one or more data streams of a specific type. To create an Aggregation report: 1. Select the stream type, the specific streams you wish to analyze, and the reporting time period. 2. Select the aggregation period - from 10 min intervals to 1 month intervals. 3. Specify the type of statistical analysis: Sum, Average, Min, Max or Standard Deviation Figure 11: Aggregation Report - Defining Report Criteria 4. Click Export to Excel. A CSV file is created, showing the results of the statistical analysis for the selected period. For example, the figure shown below displays, for each day in the period: The Minimum recorded value over all selected streams. The Maximum recorded value over all selected streams. Figure 12: Aggregation Report - Example 15
16 Daily Total Flow Report This report is relevant only to a Flow type of data stream. It displays the daily total flow for each day in the specified time period. To create a Daily Total Flow report: 1. Select the specific flow data stream and the reporting time period. Figure 13: Daily Total Flow Report - Defining Report Criteria 2. Click Export to Excel. A CSV file is created, showing the daily total flow during the specified time period. Figure 14: Daily Total Flow Report - Example 16
17 MAINTENANCE Raphael Battery Replacement As the battery nears its end of life, you will receive battery level notifications, enabling you to schedule battery replacement before the battery runs out. Replacement batteries can be ordered from Sper Scientific, part no. WA Battery Replacement Instructions 1. Beware of static discharge, making sure to work in a clean environment and ensuring that your hands and the Raphael are completely dry. 2. Place the Raphael face down on a dry, stable surface with the connectors pointing downward. 3. Partially unscrew the six (6) screws located on the back of the Raphael enclosure, until you can lift off the back panel with the screws still affixed to their screw holes. Figure 15: Unscrewing Back Cover Screws 4. Remove the Raphael s back panel and place it flat-side down adjacent to the Raphael box. 17
18 5. On the interface board, move the ON/OFF switch to the OFF position. Figure 16: Manually Turning Raphael Device On or Off 6. Carefully disconnect the male end of the battery connector cable from the female connector on the interface board. Using an indelible pen, mark the battery as Used and dispose of it properly. 7. Mark the new battery with the current date. Place the battery in the Raphael enclosure and carefully connect the male end of the battery connector cable to the female connector on the interface board. 8. Verify that the yellow, red and blue LED lights on the interface board blink briefly. This confirms that the battery has been successfully connected. 9. On the interface board, move the ON/OFF switch to the ON position. The Raphael device turns on and performs a 10-minute calibration process, after which it starts operating in normal mode 10. Replace the Raphael back panel, ensuring that the battery cable is neatly arranged and not pinched within the Raphael enclosure. 11. Tighten the six (6) back panel screws until the Raphael is closed and sealed. Do not over-tighten as this will strip the screw threads. The Raphael is now ready to resume monitoring and transmission. 18
19 TROUBLESHOOTING Raphael Device Does not Turn On Problem: Magnetic activator does not turn the Raphael on Recommended Actions: 1. Partially unscrew the six (6) screws located on the back of the Raphael enclosure (see Figure 15), until you can lift off the back panel with the screws still affixed to their screw holes. 2. Remove the Raphael s back panel and place it flat-side down adjacent to the Raphael box. 3. On the interface board, move the ON/OFF switch to the ON position (see Figure 16). The Raphael device turns on and performs a 10-minute calibration process, after which it starts operating in normal mode 4. Replace the Raphael back panel, ensuring that the battery cable is neatly arranged and not pinched within the Raphael enclosure. 5. Tighten the six (6) back panel screws until the Raphael is closed and sealed. Do not over-tighten as this will strip the screw threads. GLOSSARY Term API Cloud computing SCADA UI Explanation Application Programming Interface. A set of routines, protocols, and tools for building software and applications Internet-based computing, providing shared resources, data and information to computers and other devices on-demand. Supervisory Control And Data Acquisition. A system for remote monitoring and control. User Interface 19
20 SPECIFICATIONS Data and Software Data Server Sper Scientific User Interface Data Export Options 3rd Party Integration SCADA Integration private cloud and/or customer on-premises server Web-based, Tablet, Mobile Excel, CSV API OPC, DNP3 Data Encryption AES 256 Data Communication Internal Memory System Health Check Bidirectional Up to 32 GB Included Primary Power Supply Operational Run Time External Power Supply (Optional) Power Options Battery Level Power Internal military grade lithium battery, 9V DC 3A 3,500+ transmissions per battery pack, field replaceable battery 4.5V 28V, Automatic power source switching Solar and permanent powered compatibility Included Connectivity Cellular Network SIM Card Data Transmission Profiles Cellular Roaming Event Driven Alerts Alarm Threshold Configuration & Upgrades Antenna Multi-cellular carrier: 2G, 3G and CDMA (Verizon) Global SIM card included Periodic, Data Dependent Global SIM card supporting over 110 countries SMS, , API Up to 4 (HH, H, L, LL) Remotely over-the-air, USB PC connection Internal or external GPS Included 20
21 No. of Sensor Connectors Serial Interfaces Serial Protocols Analog Inputs Sensor Integration 3 RS232 RS485 SDI12 Modbus RTU ASCI Custom Up to 4 (current loop, voltage) Digital Inputs Up to 2 Sensor Power Supply 12 V, 350 ma Dimensions Weight Material Waterproofing Rating Storage Temperature Range Operational Temperature Range Connectors Mechanical Enclosure 13.2 cm W x 16.5 cm H x 7.3 cm D (5.2 in x 6.5 in x 2.9 in) 700g / 1.5 lbs Polycarbonate IP 68 / NEMA 6P -40 C to +80 C (-40 F to +176 F) -20 C to +60 C (-4 F to +140 F) Industrial Grade * Complies with: Radiated emission standards (ETSI EN / -17 Class B and CFR 47 FCC Part 15 Subpart B Class B), Immunity per ETSI EN /-17 EN , 3, 4, 5, 6, RoHS, Directive 2002/95/EC and. 21
22 Raphael Mechanical Drawings Figure 17: Raphael Mechanical Drawings 22
23 Raphael Block Diagram Figure 18: Raphael Block Diagram 23
24 WARRANTY Sper Scientific warrants this product against defects in materials and workmanship for a period of five (5) years from the date of purchase, and agrees to repair or replace any defective unit without charge. If your model has since been discontinued, an equivalent Sper Scientific product will be substituted if available. This warranty does not cover probes, batteries, battery leakage, or damage resulting from accident, tampering, misuse, or abuse of the product. Opening the meter to expose its electronics will break the waterproof seal and void the warranty. To obtain warranty service, ship the unit postage prepaid to: SPER SCIENTIFIC LTD E. Evans Rd., Suite #103 Scottsdale, AZ (480) The defective unit must be accompanied by a description of the problem and your return address. Register your product online at within 10 days of purchase.. 2/23/
Torque Meter. Instruction Manual
Torque Meter 840062 Instruction Manual Torque Meter - 840062 Copyright 2013 by Sper Scientific ALL RIGHTS RESERVED Printed in the USA The contents of this manual may not be reproduced or transmitted in
More informationDatalogging RH / Temperature Pen Instruction Manual
Datalogging RH / Temperature Pen 800013 Instruction Manual 1 Datalogging RH / Temperature Pen 800013 Copyright 2014 by Sper Scientific ALL RIGHTS RESERVED Printed in the USA The contents of this manual
More information4-Channel Thermometer
4-Channel Thermometer 800023 4-Channel Thermometer - 800023 Copyright 2015 by Sper Scientific ALL RIGHTS RESERVED. Printed in the USA The contents of this manual may not be reproduced or transmitted in
More informationAquaShock ph Meter K
AquaShock ph Meter 850057K 7720 E. Redfield Rd. Suite #7, Scottsdale, AZ 85260 Tel: (480) 948-4448 Fax: (480) 967-8736 Web: www.sperscientific.com AquaShock ph Meter 850057K Copyright 2011 by Sper Scientific
More informationBluetooth IR Pen. Instruction Manual
Bluetooth IR Pen 800110 Instruction Manual 1 INTRODUCTION Simply choose single, or continuous, monitoring on the App and aim the laser circle guide at the target to read the temperature. The laser circle
More informationRH/Temperature SD Card Datalogger. Instruction Manual
RH/Temperature SD Card Datalogger 800021 Instruction Manual RH/Temperature SD Card Datalogger 800021 Copyright 2010 by Sper Scientific ALL RIGHTS RESERVED Printed in the USA The contents of this manual
More informationLight Meter (Foot Candles)
Light Meter (Foot Candles) 821 Light Meter (Foot Candles) - 821 Copyright 215 by Sper Scientific ALL RIGHTS RESERVED Printed in the USA The contents of this manual may not be reproduced or transmitted
More informationAnemometer SD Card Datalogger. Instruction Manual
Anemometer SD Card Datalogger 850023 Instruction Manual 1 Anemometer SD Card Datalogger 850023 Copyright 2010 by Sper Scientific ALL RIGHTS RESERVED Printed in the USA The contents of this manual may not
More information4 Channel Datalogging Thermometer. Instruction Manual
4 Channel Datalogging Thermometer 800024 Instruction Manual 1 TABLE OF CONTENTS INTRODUCTION... 3 FEATURES... 4 MATERIALS SUPPLIED... 4 FRONT PANEL DESCRIPTION... 5 LCD DISPLAY... 6 SET UP... 7 MEASUREMENT
More informationDissolved Oxygen Meter Kit DOK. Instruction Manual
Dissolved Oxygen Meter Kit 850081DOK Instruction Manual Contact : EASTERN ENERGY CO.,LTD. (HEAD OFFICE) 40/4 Vitoondumri Rd., Banbueng, Banbueng, Chonburi 20170 Tel: 0-3844-6117, Fax: 0-3844-6200 Email:
More informationOxygen Pen Copyright 2015 by Sper Scientific ALL RIGHTS RESERVED. Printed in the USA
Oxygen Pen 800047 Oxygen Pen - 800047 Copyright 2015 by Sper Scientific ALL RIGHTS RESERVED. Printed in the USA The contents of this manual may not be reproduced or transmitted in any form or by any means
More informationWide Range Pressure Meter Instruction Manual
Wide Pressure Meter 840065 Instruction Manual Wide Pressure Meter - 840065 Copyright 2015 by Sper Scientific ALL RIGHTS RESERVED Printed in the USA The contents of this manual may not be reproduced or
More informationDIGITAL SOUND LEVEL METER. Instruction Manual
DIGITAL SOUND LEVEL METER 840029 Instruction Manual CONTENTS I. Introduction... 3 II. Panel Description... 3 III. Operating Instructions A. Measuring Procedure... 4 B. Settings for General Applications...
More information4-Channel Datalogging Thermometer
4-Channel Datalogging Thermometer 800024 4-Channel Datalogging Thermometer - 800024 Copyright 2015 by Sper Scientific ALL RIGHTS RESERVED. Printed in the USA The contents of this manual may not be reproduced
More informationDatalogging Conductivity/ TDS Meter. Instruction Manual
Datalogging Conductivity/ TDS Meter 850039 Instruction Manual 1 TABLE OF CONTENTS 1. INTRODUCTION...3 2. PANEL DESCRIPTION...4 3. MEASURING PROCEDURE...5 3-A General Measurement...5 3-B Auto and Manual
More informationVisible Light SD Card Datalogger
Visible Light SD Card Datalogger 850007 Instruction Manual Eastern Energy Co., Ltd. 40/4 Vitoondumri Rd., Banbueng Banbueng, Chonburi, Thailand Tel: 66-3844-6117 sale@ete.co.th www.eastern-energy.com Visible
More informationMini Environmental Quality Meter
Mini Environmental Quality Meter 850025 Mini Environmental Quality Meter 850025 Copyright 2012 by Sper Scientific ALL RIGHTS RESERVED Printed in the USA The contents of this manual may not be reproduced
More informationWater Quality Meter. Water Quality Meter Kit. Instruction Manual
Water Quality Meter 850081 Water Quality Meter Kit 850086 Instruction Manual Contact : EASTERN ENERGY CO.,LTD. (HEAD OFFICE) 40/4 Vitoondumri Rd., Banbueng, Banbueng, Chonburi 20170 Tel: 0-3844-6117, Fax:
More informationMini Environmental Quality Meter
Mini Environmental Quality Meter 850025 7720 E. Redfield Rd. Suite #7, Scottsdale, AZ 85260 Tel: (480) 948-4448 Fax: (480) 967-8736 Web: www.sperscientific.com Mini Environmental Quality Meter 850025 Copyright
More informationWBGT SD Card Datalogger. Instruction Manual
WBGT SD Card Datalogger 800037 Instruction Manual 1 WBGT SD Card Datalogger 800037 Copyright 2010 by Sper Scientific ALL RIGHTS RESERVED Printed in the USA The contents of this manual may not be reproduced
More informationVacuum Meter Instruction Manual
Vacuum Meter 840064 Instruction Manual TABLE OF CONTENTS 1. INTRODUCTION...2 2. METER DESCRIPTION...3 3. OPERATING INSTRUCTIONS 3-A PRECAUTIONS - READ BEFORE FIRST USE...4 3-B MEASUREMENT PROCEDURE...4
More informationAdvanced Datalogging Thermometer. Instruction Manual
Advanced Datalogging Thermometer 800008 Instruction Manual Advanced Datalogging Thermometer - 800008 Copyright 2015 by Sper Scientific ALL RIGHTS RESERVED Printed in the USA The contents of this manual
More informationAnemometer/Thermometer
Anemometer/Thermometer 840003 840003 Anemometer/ Thermometer measures both air speed and temperature in a light weight, compact unit. Measures air velocity in 5 scales: m/s, km/hr, mile/ hr, knots, or
More informationManometers 2PSI, 5PSI, 15PSI, 30PSI, 100PSI , , ,
Manometers 2PSI, 5PSI, 15PSI, 30PSI, 100PSI 840080, 840081, 840082 840083, 840085 Manometers 840080, 840081, 840082, 840083, 840085 Copyright 2015 by Sper Scientific ALL RIGHTS RESERVED Printed in the
More informationDatalogging IAQ Meter Instruction Manual
Datalogging IAQ Meter 800050 Instruction Manual Datalogging IAQ Meter 800050 Copyright 2014 by Sper Scientific ALL RIGHTS RESERVED Printed in the USA The contents of this manual may not be reproduced or
More informationSound Level Pen Instruction Manual
Sound Level Pen 840018 Instruction Manual TABLE OF CONTENTS 1. INTRODUCTION...................2 2. DESCRIPTION.................... 3 3. OPERATING INSTRUCTIONS........... 4 PRECAUTIONS AND MAINTENANCE.......4
More informationMini Environmental Quality Meter
Mini Environmental Quality Meter 850070 Mini Environmental Quality Meter 850070 Copyright 2015 by Sper Scientific ALL RIGHTS RESERVED Printed in the USA The contents of this manual may not be reproduced
More informationPsychrometer/Anemometer. Instruction Manual
Psychrometer/Anemometer 840034 Instruction Manual 1 2 TABLE OF CONTENTS Introduction...4 Front Panel Description...5 Measurement Procedures...8 Low Battery...16 USB Software...17 Troubleshooting...18 Error
More informationWBGT SD Card Datalogger. Instruction Manual
WBGT SD Card Datalogger 800037 Instruction Manual WBGT SD Card Datalogger 800037 Copyright 2010 by Sper Scientific ALL RIGHTS RESERVED Printed in the USA The contents of this manual may not be reproduced
More informationNotifEye Digital Cold Chain Instruction Manual
NotifEye Digital Cold Chain Instruction Manual Table of Contents Creating an Account... 1 New Master Account User... 2 Link Existing NotifEye Account... 3 Initial Landing Page... 4 Setting Up the Hardware...
More informationType K/J Thermometers
Type K/J Thermometers 800005 CONTENTS INTRODUCTION....2 FRONT PANEL DESCRIPTION...3 LCD DISPLAY....4 OPERATION INSTRUCTION...5 Power Up....5 Connecting the Thermocouples....5 Selecting Temperature Scale....5
More informationTestLink Software for Software Instruction Manual
TestLink Software for 800023 840004 Software Instruction Manual 1 Table of Contents Introduction... 3 System Requirements... 3 Minimum Hardware Requirement... 3 Quick Start Tutorial... 4 Recording real
More informationPROGRAMMABLE DIGITAL REFRACTOMETER INSTRUCTION MANUAL
PROGRAMMABLE DIGITAL REFRACTOMETER 300037 INSTRUCTION MANUAL 1 CONTENTS INTRODUCTION... 2 PANEL DESCRIPTION... 3 FACEPLATE & LCD DISPLAY...3 OPERATING INSTRUCTIONS General Measurement...4 Calibration Procedures...4
More informationI/R Thermometer Gun 8:1
I/R Thermometer Gun 8:1 800101, 800102 INSTRUCTION MANUAL SPER SCIENTIFIC Contents Page 1. INTRODUCTION...2 2. SAFETY SPECIFICATIONS...3 3. DISPLAY AND BUTTON LOCATIONS...4 4. BATTERY REPLACEMENT...5 5.
More informationMini Environmental Quality Meter
Mini Environmental Quality Meter 850026 Mini Environmental Quality Meter 850026 Copyright 2012 by Sper Scientific ALL RIGHTS RESERVED Printed in the USA The contents of this manual may not be reproduced
More informationLight Meter with Bar Graph
Light Meter with Bar Graph 840020 Instruction Manual SPER SCIENTIFIC LTD. TABLE OF CONTENTS INTRODUCTION... 2 PANEL DESCRIPTION... 3 MEASUREMENT PROCEDURES... 3-4 ZERO ADJUSTMENT... 4 BATTERY REPLACEMENT...
More informationTemperature Datalogger
Temperature Datalogger 800057 INTV 800057 INSTRUCTION MANUAL 3 Sec Erase MEMORY SELECT 1 Sec REC Data Logger: 64,000 Records SPER SCIENTIFIC LTD. CONTENT Page I. SAFETY INFORMATION ---------------------
More informationEYE N TIF. NotifEye. Wireless Sensors and Gateway Instructions. Contents. Identify Your Kit. Creating an Account. Setting Up the Hardware
TM N TIF EYE POWERED BY TEMPTRAK NotifEye Wireless Sensors and Gateway Instructions 1 2 3 Contents Creating an Account Creating An Account...2 Setting Up the Hardware Setting Up and Using the Gateway...3
More informationEYE N TIF. NotifEye. Wireless Sensors and Gateway Instructions. Contents. Confirm Your Kit. Creating an Account. Setting Up the Hardware
TM N TIF EYE POWERED BY TEMPTRAK NotifEye Wireless Sensors and Gateway Instructions 1 2 3 Contents Creating an Account Creating An Account...2 Setting Up the Hardware Setting Up and Using the Gateway...3
More informationDatalogging Manometers 2PSI, 5PSI, 15PSI , ,
Datalogging Manometers 2PSI, 5PSI, 15PSI 840086, 840098, 840099 Manometers 840086, 840098, 840099 Copyright 2015 by Sper Scientific ALL RIGHTS RESERVED Printed in the USA FIRST TIME USE Before using the
More informationLarge Display Salinity & Conductivity Pens &
Large Display Salinity & Conductivity Pens 850036 & 850037 Large Display Salinity & Conductivity Pens 850036 & 850037 Copyright 2013 by Sper Scientific ALL RIGHTS RESERVED Printed in the USA The contents
More informationMini Sound Meter. Instruction Manual SPER SCIENTIFIC
Mini Sound Meter 850014 Instruction Manual SPER SCIENTIFIC CONTENTS 1. INTRODUCTION... 2 2. PANEL DESCRIPTION... 3 3. OPERATING INSTRUCTIONS... 4 3-A. Measuring Procedures... 4 3-B. Hold Function... 5
More informationDatalogging ph Meter
Specifications Range Resolution Accuracy ph 0.00 ~ 14.00 ph 0.01 ph ±0.02 ph mv -999.9 ~ 999.9mV 0.1 mv ±0.2 mv @ -99.9 ~ 99.9mV ±2 mv @ other ranges Temperature -23 ~ 176 F (-5 ~ 80 C) 0.1 F( 0.1 C) Compensation
More informationDatalogging Hot Wire CFM Anemometer
Datalogging Hot Wire CFM Anemometer 840002 Instruction Manual SPER SCIENTIFIC LTD. TABLE OF CONTENTS 1. INTRODUCTION... 3 2. PANEL DESCRIPTION... 4-5 3. MEASURING PROCEDURE... 5 3-A Air Velocity and Ambient
More informationTorque Meter. Instruction Manual
Torque Meter 840062 Instruction Manual CONTENTS I. Introduction... 4 II. Meter Description... 4 III. Operating Instructions 1. Measuring Procedures... 5 2. Automatic Shut Off... 6 3. Battery Replacement...
More informationPM2.5 and PM10 Monitors , & Instruction Manual
1 PM2.5 and PM10 Monitors 900014, 900015 & 900016 Instruction Manual Contact : EASTERN ENERGY CO.,LTD. (HEAD OFFICE) 40/4 Vitoondumri Rd., Banbueng, Banbueng, Chonburi 20170 Tel: 0-3844-6117 Fax: 0-3844-6200
More informationDATALOGGER With DATA LAB GRAPHICAL SOFTWARE INSTRUCTION MANUAL SPER SCIENTIFIC
2. Open the file by selecting All Types or Text in the Files of type: box. Find the file you saved. When open, choose Tab delineated file. 3. You can now work with the data as you would any other data
More informationDatalogging Manometer
Datalogging Manometer 840086, 840098 and 840099 Instruction Manual TABLE OF CONTENTS Introduction.. 3 Front Panel Descriptions.. 4 Set-up.. 5-6 Calibration.. 7 Measurement Procedures.. 8-14 Error Codes..
More informationWireless Sensors and Ethernet Gateway Manual
Wireless Sensors and Ethernet Gateway Manual - 1 - Contents Creating An Account...5 Setting Up the Hardware...8 Setting Up and Using the Ethernet Gateway Understanding the Ethernet Gateway Lights Ethernet
More information2019 WAVELET Catalog
2019 WAVELET Catalog SEEING BEYOND THE HORIZON 5 ANCHORING DECISIONS IN DEPENDABLE DATA Managers and operators of complex infrastructures, systems, and smart services need to think quickly, act prudently,
More informationEDG Port Industrial 10/100 Mbps Ethernet Switch. User Manual
EDG-6528 8-Port Industrial 10/100 Mbps Ethernet Switch User Manual Copyright The documentation and the software included with this product are copyrighted 2005 by Advantech Co., Ltd. All rights are reserved.
More informationThermal Imaging Camera 220 x Instruction Manual
Thermal Imaging Camera 220 x 160 800201 Instruction Manual 1 TABLE OF CONTENTS INTRODUCTION... 3 FEATURES... 4 MATERIALS SUPPLIED... 4 FRONT PANEL DESCRIPTION... 5 LCD DISPLAY... 6 SET UP... 7 MEASUREMENT
More informationOwner s Manual Havis Docking Station For Getac F110 Rugged Tablet
Owner s Manual Havis Docking Station For Getac F110 Rugged Tablet Related Products Havis offers a wide variety of accessory products specifically for use with the DS-GTC-210 Series Docking Station. For
More information1. Introduction Initial setup Configure your SpotBot User Management Regulatory Compliance...
CONTENTS 1. Introduction... 3 2. Initial setup... 4 3. Configure your SpotBot... 9 4. How to use your SpotBot... 13 a. Start a Trip... 13 b. Stop a Trip... 14 c. Other information about batteries and settings...
More informationOwner s Manual Havis Docking Station For Getac F110 Rugged Tablet
Owner s Manual Havis Docking Station For Getac F110 Rugged Tablet DS-GTC-200 Series DS-GTC-201 DS-GTC-201-3 DS-GTC-202 DS-GTC-202-3 DS-GTC-203 www.havis.com 1-800-524-9900 Before Beginning (Original Instructions)
More informationDrive 3G-S ENGLISH. Cellular Signal Booster A Customer Support: Mon-Fri 8 am to 6 pm.
ENGLISH Drive 3G-S Cellular Signal Booster A512626 ENGLISH!! IT IS VERY IMPORTANT TO POWER YOUR SIGNAL BOOSTER USING A SURGE PROTECTED AC POWER STRIP WITH AT LEAST A 1000 JOULE RATING. FAILURE TO DO THIS
More information2 Mesa Ethernet Dock User s Manual
owner s manual Mesa Ethernet Dock The Mesa Ethernet Dock is an optional accessory that provides an ethernet port for networking, power input jack, USB client port, and a mounting station for the Mesa Rugged
More informationSOFREL LT/LT-US Data loggers Wastewater network solutions
SOFREL LT/LT-US Data loggers Wastewater network solutions SOFREL LT and LT-US data loggers are designed to monitor wastewater and rainwater networks (collectors, Combined Sewer Overflows, etc.). Robust,
More informationPH SD Card Datalogger. Instruction Manual
PH SD Card Datalogger 850060 Instruction Manual PH SD Card Datalogger 850060 Copyright 2010 by Sper Scientific ALL RIGHTS RESERVED Printed in the USA The contents of this manual may not be reproduced or
More informationBlueSet Wireless Headset Interface User Guide
BlueSet Wireless Headset Interface User Guide JK Audio Description The BlueSet series of intercom headset adaptors use Bluetooth Wireless Technology to add wireless freedom to your intercom system. BlueSet
More informationPWRguard PLUS Spring City Drive Waukesha, WI
PWRguard PLUS www.westmountainradio.com 1020 Spring City Drive Waukesha, WI 53186 262-522-6503 sales@westmountainradio.com 2016, All rights reserved. All trademarks are the property of their respective
More informationSOUND LEVEL PEN INSTRUCTION MANUAL SPER SCIENTIFIC
SOUND LEVEL PEN 840018 INSTRUCTION MANUAL SPER SCIENTIFIC CONTENTS I. Introduction... 2 II. Description... 3 III. Operating Instructions... 4 Precautions and Maintenance.. 4 Calibration... 4-5 Measurement...
More informationDO Meter Kit. Instruction Manual
DO Meter Kit 850048 Instruction Manual DO Meter Kit 850048 Copyright 2013 by Sper Scientific ALL RIGHTS RESERVED Printed in the USA The contents of this manual may not be reproduced or transmitted in any
More informationUSB 2.0 RG2324/ Port USB 2.0 Fiber Optic Extender System. User Guide
USB 2.0 RG2324/2344 4-Port USB 2.0 Fiber Optic Extender System User Guide Thank you for purchasing the USB 2.0 RG2324 or RG2344. This document applies to the following part numbers: Please read this guide
More informationProduct description The SWH is a board Cellular Terminal solution for GSM GPS/GLONASS
SWH Product description The SWH is a board Cellular Terminal solution for GSM GPS/GLONASS Rev.1 01/03/2013 1. Overview The SWH is a complete board Cellular Terminal solution for GSM GPS/GLONASS applications.
More informationPOCKET DIGITAL REFRACTOMETERS ~
POCKET DIGITAL REFRACTOMETERS 300051 ~ 300055 INSTRUCTION MANUAL SPER SCIENTIFIC LTD. CONTENTS 1. Introduction... 3 2. Panel Description... 4-5 3. Calibration... 6 4. Measurement... 7 Models with Multiple
More informationALL-IN-ONE, SENSORS-TO-CLOUD CELLULAR GATEWAY. User Manual. Stevens Part # A2 (4G LTE) Stevens Part # B2 (Verizon) Manual Version 1.
ALL-IN-ONE, SENSORS-TO-CLOUD CELLULAR GATEWAY User Manual Stevens Part #80060-70A2 (4G LTE) Stevens Part #80060-70B2 (Verizon) Manual Version 1.2 Contents 1. PRODUCT OVERVIEW... 3 2. SPECIFICATIONS...
More informationKramer Electronics, Ltd. USER MANUAL. Model: RC-52N. Room Controller
Kramer Electronics, Ltd. USER MANUAL Model: RC-52N Room Controller Contents Contents 1 Introduction 1 2 Getting Started 1 3 Overview 2 4 Your RC-52N 3 4.1 The RC-52N Front Panel 3 4.2 The RC-52N Rear Panel
More informationSensus T866 MicroRTU. Remote Input/Output Control. Applications. Reporting Methods DATA SHEET
Sensus T866 MicroRTU Remote Input/Output Control The Sensus Distribution Automation (DA) T866 MicroRTU is a cost effective solution for monitoring, controlling, and operating remote equipment such as switches,
More informationAdvanced Datalogging Sound Meter Instruction Manual
Advanced Datalogging Sound Meter 850013 Instruction Manual Advanced Datalogging Sound Meter - 850013 Copyright 2015 by Sper Scientific ALL RIGHTS RESERVED Printed in the USA The contents of this manual
More informationUSB Ranger Fiber Optic USB 2.0 Extender. User Guide
USB Ranger 2224 Fiber Optic USB 2.0 Extender User Guide Thank you for purchasing the USB Ranger 2224. Please read this guide thoroughly. This document applies to Part Numbers: 00-00260, 00-00261, 00-00262,
More informationMP3 Speaker USER GUIDE
MP3 Speaker USER GUIDE Jazwares, Inc. 2012 CONTENTS Please read the instructions along with the Speaker carefully before you use it, so that you can operate it conveniently. WELCOME, Warnings & Safety
More informationKramer Electronics, Ltd.
Kramer Electronics, Ltd. Preliminary USER MANUAL Model: VM-2HDCPxl 1:2 DVI Distributor Contents Contents 1 Introduction 1 2 Getting Started 1 2.1 Quick Start 2 3 Overview 3 3.1 About HDCP 3 3.2 Defining
More informationUser Manual EKI-6528TI/ 6528TPI. EN port M12 Unmanaged/ PoE Switch with Wide Temperature
User Manual EKI-6528TI/ 6528TPI EN50155 8-port M12 Unmanaged/ PoE Switch with Wide Temperature Copyright The documentation and the software included with this product are copyrighted 2006 by Advantech
More informationAQ-DM-5BT - DIGITAL MEDIA LOCKER OWNERS MANUAL. for Bluetooth & MP3 devices PLEASE READ THIS INSTRUCTION MANUAL BEFORE INSTALLATION AND OPERATION
products with a watertight reputation AQ-DM-5BT - DIGITAL MEDIA LOCKER for Bluetooth & MP3 devices OWNERS MANUAL PLEASE READ THIS INSTRUCTION MANUAL BEFORE INSTALLATION AND OPERATION Table of Contents
More informationP OCKET POWER 9000 T. Powerful Universal Portable Charger PLEASE READ BEFORE OPERATING THIS EQUIPMENT
P OCKET POWER 9000 T M Powerful Universal Portable Charger PLEASE READ BEFORE OPERATING THIS EQUIPMENT HALO POCKET POWER 9000 Thank you for choosing HALO. Innovative, fashionable and easy to use, the HALO
More informationOperating Instructions
6000 Operating Instructions Content Warning 3-5 Illustration 6 Accessories 7 Operation Instructions 8 Specifications 9 Features 10-11 Demonstration 12-14 If the power charger does NOT charge your mobile
More informationGlobal Water Instrumentation, Inc.
Instrumentation, Inc. 11390 Amalgam Way Gold River, CA 95670 T: 800-876-1172 Int l: (916) 638-3429, F: (916) 638-3270 Display: EZ100 11/12/04-1 - Congratulations on your purchase of the EZ100 Display.
More informationKRAKEN 12,000 MONSTER POWER BANK. Owner s Manual
KRAKEN 12,000 MONSTER POWER BANK Charzon name, logo are the trademarks of Charzon Brands. Please note the use of this accessory with ipod or iphone may affect wireless performance. Apple, ipad, iphone,
More informationKramer Electronics, Ltd. USER MANUAL. Rack Adapter Model: RK-1
Kramer Electronics, Ltd. USER MANUAL Rack Adapter Model: RK-1 Contents Contents 1 Introduction 1 2 Getting Started 1 3 Overview 1 3.1 RK-1 Installation combinations 2 3.1.1 Using Blank Panels 3 3.2 Recommendations
More informationVIP-812A DUAL NETWORKED STATION PORT
ISSUE 1 VIP-812A DUAL NETWORKED STATION PORT INTRODUCTION The VIP-812A Dual Networked Station Port allows most loop start terminal devices to be connected to a managed IP-based LAN/WAN. SPECIFICATIONS
More informationFlow Meter. The most flexible flow meter
Flow Meter The most flexible flow meter Keep Smart Monitoring Simple The Signature from Teledyne Isco is not just another open channel flow meter it is a highly flexible monitoring platform, adapting right
More informationInstallation and User Guide
Installation and User Guide VADDIO DOMEVIEW HD INDOOR PENDANT MOUNT DOME ENCLOSURE FOR THE VADDIO HD-20, HD-19 AND HD-18 PTZ CAMERAS Part Number: 998-9100-200 2011 Vaddio - All Rights Reserved DomeVIEW
More informationBall Probe Moisture Meter With Bluetooth
User Manual Ball Probe Moisture Meter With Bluetooth Model MR59 Table of Contents 1. Advisories... 3 1.1 Copyright... 3 1.2 Quality Assurance... 3 1.3 Documentation... 3 1.4 Disposal of Electronic Waste...
More informationP OCKET POWER 6000 T. Powerful Universal Portable Charger PLEASE READ BEFORE OPERATING THIS EQUIPMENT
P OCKET POWER 6000 T M Powerful Universal Portable Charger PLEASE READ BEFORE OPERATING THIS EQUIPMENT HALO POCKET POWER 6000 Thank you for choosing HALO. Innovative, fashionable and easy to use, the HALO
More informationBroadband Automatic Disconnect Switch. User Manual
Reset/Test Primary/ Primary Broadband Automatic Disconnect Switch User Manual Local Power Remote Pwer Local 63V Fault Secondary Select Secondary 220V Normal 990-1929 09/2004 Introduction Introduction
More informationUser Manual. SSA-20 - CO 2 Incubator Analyser
User Manual SSA-20 - CO 2 Incubator Analyser 1 Introduction The SSA-20 is the new handheld CO 2 analyser specially designed by Samson Scientific to measure, verify and validate the CO 2 levels on CO 2
More informationUSB 3.0 Spectra Port USB m Multimode Fiber Extender System. User Guide
USB 3.0 Spectra 3022 2-Port USB 3.0 100m Multimode Fiber Extender System User Guide Thank you for purchasing the USB 3.0 Spectra 3022. Please read this guide thoroughly. This document applies to Part Numbers:
More informationREQUIREMENTS FOR WIRELESS, WEB-BASED MONITORING EQUIPMENT AND SERVICES FOR PUMP STATION APPLICAITONS
REQUIREMENTS FOR WIRELESS, WEB-BASED MONITORING EQUIPMENT AND SERVICES FOR PUMP STATION APPLICAITONS MANUFACTURER REQUIREMENTS The Manufacturer of the equipment and provider of related services shall provide
More informationOwner's Manual. For latest instructions please go to
mycharge name and logo are registered trademarks of RFA Brands. 2012-2013 RFA Brands. All Rights Reserved. Patent Pending. Made in China. IB-MYC05001RM Owner's Manual For latest instructions please go
More informationTemperature logger with display Instruction Manual
LOGGER S0110 Temperature logger with display Instruction Manual Instruction manual for use of temperature logger S0110 Logger is designed for measurement and record of temperature from built-in internal
More informationGuide Specification for 3G Wireless Battery Monitoring System
Guide Specification for 3G Wireless Battery Monitoring System 3/11A FirstLine Wireless BMS 1 1.0 Scope This specification defines the minimum requirements for a predictive FirstLine Wireless Battery Monitoring
More informationAarlogic TER-GX910. Product description. Rev.9 17/03/2013
Aarlogic TER-GX910 Product description Rev.9 17/03/2013 Contents 1 Overview... 3 2 Hardware Interface Description... 3 2.1 Main features of the TER-GX910... 3 2.2 Hardware block diagram... 4 3 Interface
More informationIP68. Autarkic Data Loggers - MT-051 / MT-713 / MT-723
Autarkic Data Loggers - MT-051 / MT-713 / MT-723 Use in the most demanding environments These data loggers are designed for use in difficult to reach and widely distributed locations. In places where neither
More informationW IRELESS8000 T. Powerful Universal Portable Charger PLEASE READ BEFORE OPERATING THIS EQUIPMENT
W IRELESS8000 T M Powerful Universal Portable Charger PLEASE READ BEFORE OPERATING THIS EQUIPMENT HALO WIRELESS 8000 Thank you for choosing HALO. The HALO WIRELESS 8000 is a portable charger with 8000mAh
More informationEverPump Wireless Pump control system
EverPump Wireless Pump control system User Guide Revision 1.0 Wireless Solutions at Work www.orbitcoms.com Page 1 Orbit Communications Pty Ltd Unit 1, 16 Donaldson Street Wyong, NSW 2259 Australia Phone
More informationVE8014A/VE8014AR QUAD NETWORKED STATION PORT
ISSUE 2 VE8014A/VE8014AR QUAD NETWORKED STATION PORT INTRODUCTION The VE8014A/VE8014AR Quad Networked Station Port allows most loop start terminal devices to be connected to a managed IP-based LAN/WAN.
More informationDP-222Q Color Video Door Phone Manual
DP-222Q Color Video Door Phone Manual * has 6 LEDs for nighttime operation Remotely and securely talk to visitors and unlock doors, gates, etc. from the Easily connect a secondary * Simple 2-wire connection
More informationMagnetic base Indicator light Microphone Camera lens Micro SD card slot Infrared light Front Side Pivot connector Built-in speakers
Niro USER MANUAL Contents Introduction 4 Product Features 5 Niro LED Indicators 6 What s Included 7 Wi-Fi Requirements 8 Mobile Device Requirements 8 Garage Door Opener Requirements 8 Download the Momentum
More informationKramer Electronics, Ltd. USER MANUAL. Model: VS-4x4FW. 4x4 FireWire Switcher
Kramer Electronics, Ltd. USER MANUAL Model: VS-4x4FW 4x4 FireWire Switcher Contents Contents 1 Introduction 1 2 Getting Started 1 2.1 Quick Start 1 3 Overview 3 4 Your FireWire Switcher 4 5 Using the FireWire
More information