1 User Manual Installation Open Dual-Band Industrial Access-Point / Client / Access- Bridge OpenBAT-Family: BAT-R Release 01 11/2012 Technical Support

2 The naming of copyrighted trademarks in this manual, even when not specially indicated, should not be taken to mean that these names may be considered as free in the sense of the trademark and tradename protection law and hence that they may be freely used by anyone Hirschmann Automation and Control GmbH Manuals and software are protected by copyright. All rights reserved. The copying, reproduction, translation, conversion into any electronic medium or machine scannable form is not permitted, either in whole or in part. An exception is the preparation of a backup copy of the software for your own use. For devices with embedded software, the end-user license agreement on the enclosed CD applies. The performance features described here are binding only if they have been expressly agreed when the contract was made. This document was produced by Hirschmann Automation and Control GmbH according to the best of the company's knowledge. Hirschmann reserves the right to change the contents of this document without prior notice. Hirschmann can give no guarantee in respect of the correctness or accuracy of the information in this document. Hirschmann can accept no responsibility for damages, resulting from the use of the network components or the associated operating software. In addition, we refer to the conditions of use specified in the license contract. You can get the latest version of this manual on the Internet at the Hirschmann product site ( Printed in Germany Hirschmann Automation and Control GmbH Stuttgarter Str Neckartenzlingen Germany Tel.: BAT-R

3 Contents Safety instructions 5 About this manual 12 Key 12 1 Device description General device description Device name Combination options Device view Power supply Operating voltage type W Operating voltage type C Operating voltage type K Devices with operating voltage type W: Power over Ethernet (PoE) Ethernet ports Gigabit combo port /100/1000 Mbit/s twisted pair connection (optional) Connections for external antennas Display elements Meaning of the LEDs Device state Port state Management interfaces V.24 interface (external management) USB interface Signal contact Operation element (reset button) 27 2 Device installation Overview of installation Unpacking and checking Installing the device and grounding Mounting on the DIN rail Wall mounting 30 Release 01 11/2012 3

4 2.3.3 Grounding Installing the SFP modules (optional) Mounting external antennas Wiring the terminal blocks (optional) Operating voltage type W Operating voltage type C Operating voltage type K Signal contact Startup procedure Mounting the terminal blocks and switching on the supply voltage Connecting the voltage supply via PoE Connecting the data lines Gigabit combo port /100/1000 Mbit/s twisted pair connection (optional) 37 3 Configuring the devices Basic set-up Configuring external antennas 38 4 Maintenance and service 41 5 Disassembly 42 6 Technical data 43 A Further Support 55 4 Release 01 11/2012

5 Safety instructions Important Information Notice: Read these instructions carefully, and look at the equipment to become familiar with the device before trying to install, operate, or maintain it. The following special messages may appear throughout this documentation or on the equipment to warn of potential hazards or to call attention to information that clarifies or simplifies a procedure. This is the safety alert symbol. It is used to alert you to potential personal injury hazards. Obey all safety messages that follow this symbol to avoid possible injury or death. The addition of this symbol to a Danger or Warning safety label indicates that an electrical hazard exists, which will result in personal injury if the instructions are not followed. DANGER DANGER indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury. WARNING WARNING indicates a potentially hazardous situation which, if not avoided, can result in death or serious injury. CAUTION CAUTION indicates a potentially hazardous situation which, if not avoided, can result in minor or moderate injury. Note: A note contains important information on the product, on how to manage the product, or on the respective section of the documentation to which your special attention is being drawn. Release 01 11/2012 5

6 Certified usage The device may only be employed for the purposes described in the catalog and technical description, and only in conjunction with external devices and components recommended or approved by the manufacturer. The product can only be operated correctly and safely if it is transported, stored, installed and assembled properly and correctly. Furthermore, it must be operated and serviced carefully. Supply voltage Note: The supply voltage is electrically isolated from the housing. WARNING ELECTRIC SHOCK Ground the device before connecting the power supply. Only connect a supply voltage as described in the data plate of your device. Failure to follow these instructions can result in death, serious injury, or equipment damage. For every supply voltage to be connected, make sure the following requirements are met: The power supply conforms to overvoltage category I or II. The voltage supply has an easily accessible disconnecting device (e.g. a switch or a plug). The disconnecting device is clearly identified so that in the case of an emergency, it is clear which disconnecting device belongs to which line. The lines to be connected are voltage-free. There is a fuse in the outer conductor (AC) or the positive conductor (DC) of the voltage supply. Regarding the properties of this fuse: See General technical data on page 43. When using a DC voltage supply: the fuse is suitable for DC voltage. If the neutral conductor (AC) or the negative conductor (DC) is not grounded: there is a fuse on each of the two wires. AC voltage Supply: the wire diameter for the input supply line is at least 0.75 mm² (North America: AWG18). DC voltage Supply: the wire diameter for the input supply line is at least 1 mm² (North America: AWG16). The cross-section of the protective conductor cable is the same size as or bigger than the cross-section of the voltage supply cables. 6 Release 01 11/2012

7 The connection cables used are permitted for the specified temperature range. Relevant for North America: The power supply lines are made up of copper wire (75 C). WARNING ELECTRIC SHOCK Only start connecting the supply voltage if all the above mentioned requirements are fulfilled. Failure to follow these instructions can result in death, serious injury, or equipment damage. Only for device variants with operating voltage type C or W: The devices are designed for operation with extra-low voltage (SELV). Accordingly, SELV circuits with voltage restrictions in accordance with IEC/EN may be connected to the supply voltage connectors. Make sure that the electrical installation meets local or nationally applicable safety regulations. Use undamaged parts. The device does not contain any service components. Internal fuses are only triggered if there is a fault in the device. If the device is not functioning correctly, or if it is damaged, switch off the supply voltage and return the device to the plant for inspection. Only switch on the supply voltage to the device if the housing is closed, the terminal blocks are wired up correctly and the terminal blocks are connected. Connect the protective conductor with the ground screw before you set up the other connections. When removing the connections, you remove the protective conductor last. For supply voltages with protective conductor connections: first connect the protective conductor before connecting the lines for the supply voltages. If your device has a second voltage supply connection of this type: here you also first connect the protective conductor before connecting the lines for the supply voltages. Shielded ground The shielded ground wire of the twisted pairs lines is connected to the front panel as a conductor. Beware of possible short circuits when connecting a cable section with conductive shield braiding. Release 01 11/2012 7

8 Housing WARNING ELECTRIC SHOCK Never insert any pointed objects (small screwdrivers, wires, etc.) into the product! Never insert sharp objects (small screwdrivers, wires, etc.) into the connection terminals for the supply voltage or the signal contact, and do not touch the terminals! Only for device variants with installation type B (interior maintenance area): Only install this device in a switch cabinet or in an operating site with limited access, to which only maintenance staff have access. Failure to follow these instructions can result in death, serious injury, or equipment damage. WARNING FIRE HAZARD Install the device in a fire protected enclosure according to EN In the following exceptional cases, you do not require a fire-protected shell: You are supplying voltage to the device only via PoE. You are supplying only 24 V to the device and are using a fuse. Regarding the properties of this fuse: See General technical data on page 43. Failure to follow these instructions can result in death, serious injury, or equipment damage. Only technicians authorized by the manufacturer are permitted to open the housing. 8 Release 01 11/2012

9 The device is grounded by the separate ground screw on the front panel. Make sure that the electrical installation meets local or nationally applicable safety regulations. The ventilation slots must not be covered to promote free air circulation. Make sure there is at least 10 cm of space above and below the device. Make sure there is at least 2 cm of space on the right and left sides of the device. The device must be installed in the vertical position. Environment The device may only be operated at the specified surrounding air temperature (temperature of the surrounding air at a distance of up to 5 cm (1.97 in) from the device) and relative air humidity specified in the technical data. Install the device in a location where the climatic threshold values specified in the technical data will be observed. Use the device only in an environment within the pollution degree specified in the technical data. When installing external antennas, adhere to the regulations of the country in which you are operating the WLAN device. In ambient temperatures under -10 C, use cabling designed for minimum temperatures. Lightning protection DANGER LIGHTNING STRIKE AND VOLTAGE SURGES Protect antennas installed outside with lightening protection devices (e.g. lightening conductors). Install overvoltage protectors on every cable. Failure to follow these instructions will result in death, serious injury, or equipment damage. See the information in the WLAN Outdoor Guide, chapter Lightning and Surge Voltage Protection. You are responsible for undertaking suitable lightning protection measures to neutralize the effects of lightning strikes. Make sure that devices are installed by a qualified electrician in accordance with the valid local, regional and national guidelines, laws and standards (such as VDE 0182 and IEC 62305), and in a manner suitable for the recognized and proven processes for the application and the environment. Release 01 11/2012 9

10 Qualification requirements for personnel Qualified personnel as understood in this manual and the warning signs, are persons who are familiar with the setup, assembly, startup, and operation of this product and are appropriately qualified for their job. This includes, for example, those persons who have been: trained or directed or authorized to switch on and off, to ground and to label power circuits and devices or systems in accordance with current safety engineering standards; trained or directed in the care and use of appropriate safety equipment in accordance with the current standards of safety engineering; trained in providing first aid. General safety instructions This device is operated by electricity. You must follow precisely the prescribed safety requirements for the voltage connections in this document. See Supply voltage on page 6. Non-observance of these safety instructions can therefore cause material damage and/or injuries. Only appropriately qualified personnel should work on this device or in its vicinity. Qualified personnel must be thoroughly familiar with the warnings and maintenance procedures in accordance with this operating manual. The proper and safe operation of this device depends on proper handling during transport, proper storage and assembly, and conscientious operation and maintenance procedures. Never start operating the device with damaged components. Only use the devices in accordance with this manual. In particular, observe the warnings and safety-related information. Any work that may be required on the electrical installation may only be carried out by personnel trained for this purpose. Note: LED or LASER components in compliance with IEC (2007): CLASS 1 LASER PRODUCT CLASS 1 LED PRODUCT National and international safety regulations Make sure that the electrical installation meets local or nationally applicable safety regulations. CE marking The labeled devices comply with the regulations contained in the following European directive(s): 10 Release 01 11/2012

11 1999/5/EC (R&TTE) Directive of the European Parliament and the council for radio installations and telecommunication systems and for the mutual recognition of their conformity. This directive also contains the goals of directive 2004/108/EC of the European Parliament and the council for standardizing the regulations of member states relating to electromagnetic compatibility, and directive 2006/95/EC of the European Parliament and the council for standardizing the regulations of member states relating to electrical equipment to be used within specific voltage ranges, but without applying the lower voltage threshold. This product may be operated in all EU (European Union) countries under the condition that it has been configured correctly. 2011/65/EU (RoHS) Directive of the European Parliament and of the Council on the restriction of the use of certain hazardous substances in electrical and electronic equipment. In accordance with the above-named EU directive(s), the EU conformity declaration will be at the disposal of the relevant authorities at the following address: Hirschmann Automation and Control GmbH Stuttgarter Str Neckartenzlingen Germany Tel.: The product can be used in living areas (living area, place of business, small business) and in industrial areas. Recycling note After usage, this product must be disposed of properly as electronic waste, in accordance with the current disposal regulations of your county, state and country. Release 01 11/

12 About this manual The Installation user manual contains a device description, safety instructions, a description of the display, and the other information that you need to install the device. You will find additional documents as PDF files on the enclosed CD ROM. The Industrial HiVision Network Management Software provides you with additional options for smooth configuration and monitoring: Simultaneous configuration of multiple devices Graphic interface with network layout Auto-topology discovery Event log Event handling Client/server structure Browser interface ActiveX control for SCADA integration SNMP/OPC gateway. Key The symbols used in this manual have the following meanings: Listing Work step Subheading 12 Release 01 11/2012

13 1 Device description 1.1 General device description The devices allow you to set up WLANs (Wireless Local Area Networks) in a local network. In contrast to a conventional network connection via copper cables and glass fibers, some of the communication is performed by means of a radio link. The devices allow you to install a new LAN or expand an existing LAN. Thanks to their high level of flexibility, you can combine large, small, mobile and non-mobile locations. Anywhere that high bandwidths, stable operation and network security is required, wireless LAN with these devices provides the ideal solution. The devices are dual-band industrial high-performance wireless LAN access points or clients complying with IEEE a/b/g/h and n. They provide a high radio output with a bandwidth of up to 450 Mbit/s. The devices support MIMO (Multiple Input Multiple Output) and Multipath. The bandwidth is increased by using the multipath transmission by means of reflections. Each WLAN module has 3 antennas for sending and receiving, to ensure stable network coverage with few shadow areas. You can choose from between a wide range of variants. You can set up your device individually based on different criteria: Number of WLAN modules Number of ports Voltage range Temperature range Access point or client Installation area Software options The BAT-R devices are designed for the special requirements of industrial automation. They meet the relevant industry standards, provide very high operational reliability, even under extreme conditions, and also provide longterm reliability and flexibility. The devices work without a fan. The following installation options are available: simply snapping them onto a DIN rail Mounting on the wall Release 01 11/

14 You can choose various media to connect terminal devices and other infrastructure components: twisted pair cable multimode F/O singlemode F/O There are convenient options for managing the device. Administer your devices via: a Web browser SSH Telnet HiDiscovery (software for setting up operation of the device) management software (e.g. Industrial HiVision, LANconfig/LANmonitor) a V.24 interface (locally on the device) The devices provide you with a large range of functions. Information pertaining to these functions is found in the relevant operating software manuals. These manuals are available as PDF files on the CD ROM provided, or you can download them from the Internet on the Hirschmann product pages ( The Hirschmann network components help you ensure continuous communication across all levels of the company network. 1.2 Device name The device name corresponds to the product code. The product code is made up of variables with defined positions. The variable values stand for specific product characteristics (see table 1). Item Product characteristic Characteri Value for the characteristic stic value Devices of the OpenBAT BAT-R DIN Rail housing family Country approvals EU Europe (CE) 8 Slot 1 W WLAN module 9 Slot 2 W WLAN module 9 Not assembled 10 Slot 3 9 Not assembled 11 Access point or client A Access Point C Client Table 1: Device name 14 Release 01 11/2012

15 Item Product characteristic Characteri Value for the characteristic stic value 12 Operating voltage 1 C Rated voltage range DC 24 V V K Rated voltage range DC 60 V V Rated voltage range AC 110 V V, 50 Hz Hz W Nominal voltage DC 24 V 13 Operating voltage 2 C Rated voltage range DC 24 V V K Rated voltage range DC 60 V V Rated voltage range AC 110 V V, 50 Hz Hz W Nominal voltage DC 24 V 9 Not present 14 Approvals 1 9 No additional approvals 15 Approvals 2 9 No additional approvals 16 Mounting A Indoor operator access area a B Indoor service access area b Ethernet port 1 O7 Combo port you can use these ports for alternative purposes: RJ45 socket for 10/100/1000 Mbit/s twisted-pair connection (PoEcapable for devices with operating voltage type W) SFP slot for 1000 Mbit/s F/O connection Ethernet port 2 T1 RJ45 socket for 10/100/1000 Mbit/s twisted-pair connection 99 Not present 21 Temperature range S Standard +32 F F (0 C C) T Extended 40 F F ( 40 C C) 22 Software option 1 A VPN-5 9 Not present 23 Software option 2 9 Not present 24 Software option 3 D Public Spot 9 Not present Table 1: Device name a. Location for which one of the following conditions apply when one operates it correctly: - The area is accessible without tools. - The person responsible for the area has provided access for the operator intentionally. - The operator knows of the access possibilities, regardless of whether they need a tool. b. Location outside the operator area to which the service personnel has access, even when the device is switched on. Release 01 11/

16 Figure 1: Example of a device name: BAT-REUW99AWW99AO7T1T Release 01 11/2012

17 Release 01 11/ Combination options Item Product Model Country Slots 1 to 3 Access Operating Certificates Installation Ethernet Ethernet Temperatu Software characteris tic approvals point or client voltage 1 and 2 1 and 2 port 1 port 2 re range options 1 to 3 Attribute values Table 2: BAT-R EU W99 A; C WW 99 A; B O7 T1; 99 S; T 999; A99; A9D; 99D BAT-R EU W99; WW9 A; C CC 99 A; B O7 T1; 99 S; T 999; A99; A9D; 99D BAT-R EU W99; WW9 A; C K9; KK; CK 99 B O7 T1; 99 S; T 999; A99; A9D; 99D Combination options of the BAT-R device variants

18 1.4 Device view a 4b 5 6 5a 6a 12 5b 6b c 6c 10 5d 7 6d WLAN module 1: 3 reverse SMA connection 2 Optional: WLAN module 2: 3 reverse SMA connection 3 LED display elements for device status 4 Ethernet port 1 Combo port you can use these ports for alternative purposes: 4a RJ45 socket for 10/100/1000 Mbit/s twisted-pair connection (PoE-capable for devices with operating voltage type W) 4b SFP slot for 1000 Mbit/s F/O connection 5 Device variants with type C or K operating voltage 5a Connection for supply voltage 1 Power supply unit type C 2-pin terminal block Power supply unit type K 3-pin terminal block 5b Connection for signal contact 1 5c Optional: Connection for supply voltage 2 Power supply unit type C 2-pin terminal block Power supply unit type K 3-pin terminal block 5d For devices with 2 power supply units: Connection for signal contact 2 Table 3: Front view of the BAT-R devices: Left: device variants with operating voltage C or K Right: device variants with operating voltage W 18 Release 01 11/2012

19 6 Device variants with type W operating voltage 6a Connection for signal contact 1 2-pin terminal block 6b Connection for signal contact 2 2-pin terminal block 6c Connection for supply voltage 1 2-pin terminal block 6d Connection for supply voltage 2 2-pin terminal block 7 Grounding screw 8 Locking gate for removing the device 9 V.24 interface 10 Reset button 11 USB interface 12 Optional: Ethernet port 2 RJ45 socket for 10/100/1000 Mbit/s twisted-pair connection Table 3: Front view of the BAT-R devices: Left: device variants with operating voltage C or K Right: device variants with operating voltage W 1.5 Power supply For redundant and outfall-resistant power, you can connect multiple power sources in any combination at the same time. The device automatically selects the power supply. Note: Switch over to a redundant power supply may not be seamless. If the power supply currently active is interrupted and another power supply takes over, the device may reboot to activate the redundant power supply Operating voltage type W A 2-pin terminal block is available to supply the device. You will find more information on page Operating voltage type C A 2-pin terminal block is available to supply the device. You will find more information on page Operating voltage type K A 3-pin terminal block is available to supply the device. You will find more information on page 34. Release 01 11/

20 1.5.4 Devices with operating voltage type W: Power over Ethernet (PoE) The devices are powered devices complying with the PoE standard 802.3af. You can therefore conveniently supply these devices with power via the LAN cabling. This makes it unnecessary to have a separate power supply for every individual device, thus considerably reducing the installation work. The power supply to the LAN is input centrally, or via a PoE injector or a power hub/power switch. You will find more information on page Ethernet ports You can connect terminal devices and other segments on the ports of the device via twisted pair cables or F/O cables Gigabit combo port Alternatively, you can connect F/O (via SFP modules) or twisted pairs to a combo port. Note: Plug a connector or SFP module that you want to use for the data transmission only into the socket of the combo port. Only for devices with voltage supply type W: 10/100/1000 Mbit/s twisted-pair connection, PoE-capable These connections are RJ45 sockets. The device is supplied with PoE voltage via these connections. 10/100/1000 Mbit/s TP ports enable the connection of terminal devices or independent network segments according to the IEEE BASE- T/100BASE-TX/1000BASE-T standard. These ports support: Autonegotiation Autopolarity Autocrossing (if autonegotiation is activated) 1000 Mbit/s full duplex 100 Mbit/s half-duplex mode, 100 Mbit/s full duplex mode 10 Mbit/s half-duplex mode, 10 Mbit/s full duplex mode Delivery state: autonegotiation activated The socket housing is electrically connected to the front panel. The pin assignment corresponds to MDI-X. 20 Release 01 11/2012

21 Figure Pin Function PoE voltage feed BI_DB+ Minus terminal of the supply voltage 2 BI_DB- Minus terminal of the supply voltage 3 BI_DA+ Plus terminal of the supply voltage 4 BI_DD+ Plus terminal of the supply voltage 5 BI_DD- Plus terminal of the supply voltage 6 BI_DA- Plus terminal of the supply voltage 7 BI_DC+ Minus terminal of the supply voltage 8 BI_DC- Minus terminal of the supply voltage Table 4: Pin assignment of a PoE-capable 1000 Mbit/s TP interface in MDI-X mode, RJ45 socket 10/100/1000 Mbit/s twisted pair connection These connections are RJ45 sockets. 10/100/1000 Mbit/s TP ports enable the connection of terminal devices or independent network segments according to the IEEE BASE- T/100BASE-TX/1000BASE-T standard. These ports support: Autonegotiation Autopolarity Autocrossing (if autonegotiation is activated) 1000 Mbit/s full duplex 100 Mbit/s half-duplex mode, 100 Mbit/s full duplex mode 10 Mbit/s half-duplex mode, 10 Mbit/s full duplex mode Delivery state: autonegotiation activated The socket housing is electrically connected to the front panel. The pin assignment corresponds to MDI-X. Figure Pin Function 1 BI_DB BI_DB- 6 3 BI_DA BI_DD+ 3 5 BI_DD BI_DA- 7 BI_DC+ 8 BI_DC- Table 5: Pin assignment of a 10/100/1000 Mbit/s TP interface in MDI-X mode, RJ45 socket 1000 Mbit/s F/O connection These ports are SFP slots. Release 01 11/

22 1000 MBit/s F/O ports enable the connection of terminal devices or independent network segments in compliance with the IEEE BASE-SX/1000BASE-LX standard. These ports support: Full duplex mode /100/1000 Mbit/s twisted pair connection (optional) See 10/100/1000 Mbit/s twisted pair connection on page Connections for external antennas You require external antennas for operating the devices. You can find information on the connectable antennas on the Internet under The devices have 3 reverse SMA connections (SMA = Sub-Miniature Version A) on each WLAN module. 1.8 Display elements After the operating voltage is set up, the software starts and initializes itself. Afterwards, the device performs a self-test. During this process, various LEDs light up. These actions last less than 1 minute Meaning of the LEDs The following terms describe the behavior of the LEDs: Regular flashing means that the LED is running through the described statuses in the specified sequence at intervals (e.g. red/green or red/off). Brief flashing means that the LED lights up very briefly in the color specified, then is switched off for a much longer time (about 10x as long). Inverse flashing means that the LED is switched off for a brief time and then lights up for considerably longer (about 10x as long) in the specified color. Flickering means that the LED switches on and off at irregular intervals. Running light means the coordinated glowing of several LEDs. This gives the optical impression that a light source is moving from left to right and back. 22 Release 01 11/2012

23 1.8.2 Device state These LEDs provide information about conditions which affect the operation of the whole device. LED display elements for device status P1 WLAN1 P2 WLAN2 P1 WLAN1 P When equipped with 2 WLAN modules 2 When equipped with 1 WLAN module The unlabeled LED remains off during regular operation. It only lights up after the configuration is reset (hard reset). See Operation element (reset button) on page 26. P1, P2 Power (green/red LED) Off Connection is voltage-free. a Green on continuously Voltage present, device is operational. Red/green flashing (slowly) Charge lock active. b Red/green flashing (quickly) Unprotected configuration as no password or the default password is set. b Red/off flashing (quickly) Hardware error detected. b Red/green Running light of P1 A BAT controller WLC with an incompatible protocol is and P2 connected. Green Running light of P1 Device is searching for a BAT controller WLC. and P2 a. If both connections are voltage-free, the power supply is possibly running via an active Ethernet connection at the PoE port. The port status LEDs directly on the port show you whether an Ethernet connection is active. b. Which LED displays the corresponding response depends on the configuration of the power supply connections. P2 always performs signaling if a voltage is solely present on the connection for supply voltage 2. In all other cases, signaling is performed by P1. WLAN 1, WLAN 2 (green/red LEDs) WLAN connection and WLAN data traffic of internal WLAN modules Off No WLAN network defined or WLAN module deactivated. The WLAN module does not send any beacons. Green At least one WLAN network defined and WLAN module activated. The WLAN module sends beacons. Green flashing inversely Number of flashes = number of connected WLAN stations and P2P radio lines, then there is a break. Green flashing DFS scanning or another scan procedure. Red flashing Hardware error detected in the WLAN module Port state These LEDs display port-related information. The LEDs are directly located on the ports. Release 01 11/

24 LS/DA (green/yellow LED) Data, link status Status of the LAN interfaces Off No network device connected Green on continuously Ethernet connection active Yellow flickering Data traffic 1.9 Management interfaces V.24 interface (external management) This interface is designed as an 8-pin M12 socket. The V.24 interface is a serial interface which allows you to connect the following devices locally: An external management station (VT100 terminal or PC with appropriate terminal emulation). This enables you to set up a connection to the Command Line Interface (CLI) and to the system monitor. You will find more information here: table 7, Pin assignment for the connection with a cable: M12 socket to DB9 connector, on page 25 A BAT-R device. You can use this to automate the configuration of a point-to-point WLAN line by connecting two devices directly via the serial interface. You will find more information here: User Manual Configuration and Administration Guide table 8, Pin assignment for the connection with a cable: M12 socket to M12 socket (point-to-point WLAN line), on page 25 VT 100 terminal settings Speed Data Stopbit Handshake Parity The socket housing is electrically connected to the front panel of the device. The V.24 interface is electrically insulated from the supply voltage. Note: Only use a shielded cable bit/s 8 bit 1 bit Hardware none 24 Release 01 11/2012

25 Pins of the M12 socket on the device Pin Function Description of functions 1 GND Ground 2 DTR Data terminal ready 3 TxD Transmit data 4 RxD Receive data 5 DCD Data carrier detect 6 DSR Dataset ready 7 RTS Request to send 8 CTS Clear to send 9 Ring indicator Table 6: Pin assignment of the M12 socket Pins of the M12 socket on the device Table 7: Pin assignment for the connection with a cable Pin assignment for the connection with a cable: M12 socket to DB9 connector Pins of the DB9 plug on the external device Note: You can order a terminal cable M12, 8-pin, to DB9 as an accessory. See Accessories on page Pins of the M12 socket on the device Pin assignment for the connection with a cable Pins of the M12 socket on the device Table 8: Pin assignment for the connection with a cable: M12 socket to M12 socket (point-to-point WLAN line) Release 01 11/

26 Note: With the point-to-point WLAN line, the following pins are short-circuited at both ends: 2 (DTR) + 6 (DSR) 7 (RTS) + 8 (DSR) USB interface The USB socket is an interface for the local connection of an AutoConfiguration Adapter ACA 21-USB. It is used for saving/loading the configuration data and diagnostic information, and for loading the software. The USB interface has the following properties: Supports the USB master mode Supports USB 1.1 (data rate max. 12 MBit/s) Connectors: type A Supplies current of max. 500 ma Voltage not potential-separated Figure Pin Operation 1 VCC (VBus) 2 Data 3 + Data 4 Ground (GND) Table 9: Pin assignment of the USB interface 1.10 Signal contact Figure 2: Signal contact: 2-pin terminal block with screw locking You can set the signal contact manually using the device management Operation element (reset button) With these devices, the operating elements include a reset button. 26 Release 01 11/2012

27 The reset button has two different functions, which are triggered by pressing the button for different lengths of time: Resetting the configuration (hard reset) the button is pressed for more than 5 seconds but less than 10 seconds. All LEDs on the device light up continuously in red. When the reset button is released, the device restarts with the factory settings. The hard reset can be used, for example, if you have to reconfigure the device independently of any existing settings, or if no connection to the device configuration can be made. Note: Save the current configuration of the device before the reset. After a hard reset, the device restarts with the factory settings based on the firmware used, and all custom settings are lost. Device restart (soft reset) the button is pressed for less than 5 seconds or more than 10 seconds. The device restarts. Release 01 11/

28 2 Device installation Before installing and starting up the device, note the safety instructions (see page 5 onwards). 2.1 Overview of installation Two or more devices configured with the same IP address can cause unpredictable operation of your network. WARNING UNINTENTIONAL OPERATION IN DEVICE Install and maintain a process that assigns a unique IP address to every device in the network. Failure to follow these instructions can result in death, serious injury, or equipment damage. The devices have been developed for practical application in a harsh industrial environment. On delivery, the device is ready for operation. The following steps should be performed to install and configure a BAT-R: Unpacking and checking Installing the device and grounding Installing the SFP modules (optional) Mounting external antennas Wiring the terminal blocks (optional) Startup procedure Connecting the data lines Configuring the devices 2.2 Unpacking and checking Check that the contents of the package are complete (see page 50 Scope of delivery ). Check the individual parts for transport damage. 28 Release 01 11/2012

29 2.3 Installing the device and grounding Mounting on the DIN rail WARNING FIRE HAZARD Install the device in a fire protected enclosure according to EN In the following exceptional cases, you do not require a fire-protected shell: You are supplying voltage to the device only via PoE. You are supplying only 24 V to the device and are using a fuse. Regarding the properties of this fuse: See General technical data on page 43. Failure to follow these instructions can result in death, serious injury, or equipment damage. WARNING ELECTRIC SHOCK Only for device variants with installation type B (interior maintenance area): Only install this device in a switch cabinet or in an operating site with limited access, to which only maintenance staff have access. Failure to follow these instructions can result in death, serious injury, or equipment damage. Figure 3: Mounting on the DIN rail Release 01 11/

30 Note: Make sure there is at least 10 cm of space above and below the device. Make sure there is at least 2 cm of space on the right and left sides of the device. Note: The shield ground wire of the twisted pair lines is connected to the front panel as a conductor. Mount the device on a 35 mm DIN rail in accordance with DIN EN Attach the upper snap-in guide of the device into the DIN rail and press the device down against the DIN rail until it snaps into place Wall mounting You can attach the device to a wall mounting panel available as an accessory. See Accessories on page 51. Follow the assembly instructions enclosed with the accessory Grounding The housing is grounded via the separate ground screw on the bottom right of the front panel. The device variants with operating voltage type C and K have a protective grounding. The device variants with operating voltage type W have a function grounding. Connect the ground wire to the ground screw of the device. Note: For safety reasons, make sure you only connect the ground wire before you set up the other connections. 30 Release 01 11/2012

31 2.4 Installing the SFP modules (optional) Figure 4: Gigabit Ethernet fiber optic SFP module Before attaching an SFP module, first remove the protective cap over the socket. Push the SFP module with the lock closed into the socket until it latches audibly in place. Note: For this device, only use suitable SFP modules from Hirschmann. See Accessories on page Mounting external antennas 1a 2a 1b WLAN module 1: 1a Antenna connection 1 1b Antenna connection 2 1c Antenna connection 3 2 WLAN module 2 (optional): 2a Antenna connection 1 2b Antenna connection 2 2c Antenna connection 3 2b 1c 6 2c Table 10: Antenna connections Note: When installing external antennas, make sure that you adhere to the regulations of the country in which you are operating the WLAN device, and to the general operating permission and the maximum emission levels. If you would like to connect antennas to several WLAN modules, ensure that there is a distance of at least 2 m between the antennas of the different WLAN modules. Release 01 11/

32 If you would like to connect several antennas to a WLAN module, align the antennas so that the points of the antennas point away form each other in a star shape. Install at least one external antenna on the WLAN module that you would like to use. Insert the terminators supplied into unused sockets in order to avoid radio signals from one WLAN module being received by the other WLAN module. 2.6 Wiring the terminal blocks (optional) WARNING ELECTRIC SHOCK Only connect a supply voltage as described in the data plate of your device. Never insert sharp objects (small screwdrivers, wires, etc.) into the connection terminals for the supply voltage or the signal contact, and do not touch the terminals! Failure to follow these instructions can result in death, serious injury, or equipment damage. Note: The supply voltage is electrically isolated from the housing. Note: For devices with 2 power supply units: The device provides for voltage supply redundancy with no load distribution. Both inputs are separate from one another. With non-redundant supply of the mains voltage, the device reports a power failure. You can avoid this message by changing the configuration in management, or with power supply units of the same type, you can feed the supply voltage in via both inputs Operating voltage type W Figure 5: Operating voltage type W: 2-pin terminal block with screw locking 32 Release 01 11/2012

33 Type of the voltages that can be connected DC voltage Size of the supply voltage Nominal voltage DC 24 V Voltage range DC incl. maximum tolerances 18 V V Connections + Plus terminal of the supply voltage Minus terminal of the supply voltage Table 11: Operating voltage type W: Type and size of the supply voltage, connections For every supply voltage to be connected, perform the following steps: Ensure the required conditions for connecting the supply voltage are observed (see page 6 Supply voltage ). Remove the power connector from the device. Connect the lines for the supply voltage to the + and terminals Operating voltage type C WARNING ELECTRIC SHOCK Only start connecting the supply voltage if all the above mentioned requirements are fulfilled. (see page 6 Supply voltage ) Failure to follow these instructions can result in death, serious injury, or equipment damage. Figure 6: Operating voltage type C: 2-pin terminal block with screw locking Type of the voltages that can be connected DC voltage Size of the supply voltage Rated voltage range DC 24 V V Voltage range DC incl. maximum tolerances 18 V V Connections + Plus terminal of the supply voltage Minus terminal of the supply voltage Table 12: Operating voltage type C: Type and size of the supply voltage, connections Release 01 11/

34 For every supply voltage to be connected, perform the following steps: Ensure the required conditions for connecting the supply voltage are observed (see page 6 Supply voltage ). Remove the power connector from the device. Connect the lines for the supply voltage to the + and terminals Operating voltage type K WARNING ELECTRIC SHOCK Only start connecting the supply voltage if all the above mentioned requirements are fulfilled. (see page 6 Supply voltage ) Failure to follow these instructions can result in death, serious injury, or equipment damage. Figure 7: Operating voltage type K: 3-pin terminal block with screw locking Type of the voltages Size of the supply voltage Connections that can be connected DC voltage Rated voltage range DC +/L Plus terminal of the supply voltage 60 V V /N Minus terminal of the supply Voltage range DC incl. voltage maximum tolerances Protective conductor 48 V V AC voltage Rated voltage range AC +/L Outer conductor 110 V V, 50 Hz Hz /N Neutral conductor Voltage range AC incl. Protective conductor maximum tolerances 88 V V, 47 Hz Hz Table 13: Operating voltage type K: Type and size of the supply voltage, connections 34 Release 01 11/2012

35 To connect supply voltage, perform the following steps: Ensure the required conditions for connecting the supply voltage are observed (see page 6 Supply voltage ). WARNING ELECTRIC SHOCK Only start connecting the supply voltage if all the above mentioned requirements are fulfilled. (see page 6 Supply voltage ) Only install this device in a switch cabinet or in an operating site with limited access, to which only maintenance staff have access. Failure to follow these instructions can result in death, serious injury, or equipment damage. Remove the power connector from the device. Connect the protective conductor to the protective conductor terminal. Connect the lines for the supply voltage to the terminals +/L and /N Signal contact For every signal contact to be connected, make sure the following requirements are met: The lines to be connected are voltage-free. The connected voltage is limited by a current limitation device or a fuse. Observe the electrical threshold values for signal contact (see on page 43 General technical data ). Connect the signal contact lines to the terminal block. 2.7 Startup procedure WARNING ELECTRIC SHOCK Ground the device before connecting the power supply. Failure to follow these instructions can result in death, serious injury, or equipment damage. By connecting the voltage supply via a terminal block or a LAN cable (Power over Ethernet), you start the operation of the device. Release 01 11/

36 2.7.1 Mounting the terminal blocks and switching on the supply voltage Note: Relevant for North America: The torque for tightening the screws on the power connecter to the device is 4.5 lb in (0.51 Nm). The tightening torque for fixing the signal contact terminal block to the device is 3 lb in (0.34 Nm). Use screws to secure the connecters to the device. Switch on the supply voltage Connecting the voltage supply via PoE CAUTION EQUIPMENT DAMAGE In a PoE installation, use only devices that adhere to the 802.3af standard. Failure to follow these instructions can result in injury or equipment damage. Connecting the voltage supply via PoE starts the operation of the device. 2.8 Connecting the data lines Gigabit combo port Note: Plug a connector or SFP module that you want to use for the data transmission only into the socket of the combo port. 10/100/1000 Mbit/s twisted pair connection, PoE-capable You will find more information on page 20. Install the data lines according to your requirements Mbit/s F/O connection You will find more information on page Release 01 11/2012

37 Note: Make sure that the LH ports are only connected with LH ports, SX ports are only connected with SX ports, and LX ports only with LX ports. Install the data lines according to your requirements /100/1000 Mbit/s twisted pair connection (optional) You will find more information on page 22. Install the data lines according to your requirements. Release 01 11/

38 3 Configuring the devices The following options are available for configuring the device: The wired local network (LAN). The wireless network (WLAN). Prerequisite is that the WLAN encryption (e.g. WPA2) is set suitably in a device with a wireless interface and in the configuration computer. The serial V.24 interface. The USB interface. 3.1 Basic set-up You can find information on the basic settings of the device and on the state on delivery in the following documentation on the supplied CD ROM: User Manual Configuration and Administration Guide User Manual Operation and Maintenance Guide 3.2 Configuring external antennas Note: When installing external antennas, make sure that you adhere to the regulations of the country in which you are operating the WLAN device, and to the general operating permission and the maximum emission levels. 38 Release 01 11/2012

39 Transmission power The operator of a WLAN radio installation must adhere to the applicable transmission threshold values. Use the LANconfig or the Webconfig to start the configuration of the device. (This software is located on the CD provided.) Go to the settings for Wireless LAN. Enter the country in which you are installing the device (see the following figure): Open the configuration for the physical interface to which you are connecting the antenna. On the Radio tab you will find an entry field for the antenna gain (see the following figure): Release 01 11/

40 Subtract the cable attenuation and any losses due to over voltage protector installed devices from the antenna gain, and enter the result in db in the antenna gain field. 40 Release 01 11/2012

41 4 Maintenance and service When designing this device, Hirschmann was largely able to forego using parts that are subject to waer and tear. The parts subject to wear are designed to last longer than the lifetime of the product when it is operated properly. Operate this device according to the specifications (see Technical data ). Relays are subject to natural wear. This wear depends on the frequency of the switching operations. Check the resistance of the closed relay contacts and the switching function depending on the frequency of the switching operations. Hirschmann is continually working to improve and develop our software. You should regularly check whether there is a new version of the software that provides you with additional benefits. You will find software information and downloads on the product pages of the Hirschmann website. Depending on the degree of pollution in the operating environment, check at regular intervals that the ventilation slots in the device are not obstructed. Note: You will find information about the complaints and returns procedures in the Internet under Release 01 11/

42 5 Disassembly Disconnect the data lines. Switch off the supply voltage. Disconnect the terminal blocks. Remove the external antennas. Remove the SFP module by pulling it out of the socket at the opened locking device. Close the socket with a protective cap. Disconnect the grounding. Note: For safety reasons, make sure you disconnect the grounding from all connections last. To take the device off the DIN rail, insert a screwdriver horizontally under the housing into the locking slide, pull it (without tipping the screwdriver) downwards and lift the device upwards. Figure 8: Removal from the DIN rail 42 Release 01 11/2012

43 6 Technical data General technical data Weight Power supply Power supply unit type W Power supply Power supply unit type C Power supply Power supply unit type K Device variants with type W approx g operating voltage Device variants with type C or approx g K operating voltage Nominal voltage DC 24 V Voltage range DC incl. 18 V V maximum tolerances Connection type 2-pin terminal block Power failure bypass > 10 ms at 20.4 V DC Overload current protection at Non-replaceable fuse input Back-up fuse for each voltage Nominal rating: Max. 1.5 A input when supply is via 2 Characteristic: slow blow inputs Back-up fuse when 1 voltage Nominal rating: Max A input used a Characteristic: slow blow Back-up fuse when installed in Nominal rating: Max. 6.3 A a fire-protection shell Characteristic: slow blow according to EN Rated voltage range DC 24 V V Voltage range DC incl. 18 V V maximum tolerances Connection type 2-pin terminal block Power failure bypass > 10 ms at 20.4 V DC Overload current protection at Non-replaceable fuse input Back-up fuse for each voltage Nominal rating: Max. 1.5 A input when supply is via 2 Characteristic: slow blow inputs Back-up fuse when 1 voltage Nominal rating: Max A input used b Characteristic: slow blow Back-up fuse when installed in Nominal rating: Max. 6.3 A a fire-protection shell Characteristic: slow blow according to EN Rated voltage range AC 110 V V, 50 Hz Hz Voltage range AC incl. 88 V V, 47 Hz Hz maximum tolerances Rated voltage range DC 60 V V Voltage range DC incl. 48 V V maximum tolerances Connection type 3-pin terminal block Power failure bypass > 10 ms at 98 V AC Overload current protection at Non-replaceable fuse input Back-up fuse for each voltage Nominal rating: 2.5 A input Characteristic: slow blow Release 01 11/

User Manual. Installation Industrial Ethernet Rail Switch SPIDER PD SPIDER 1TX/1FX-SM PD EEC

User Manual. Installation Industrial Ethernet Rail Switch SPIDER PD SPIDER 1TX/1FX-SM PD EEC User Manual Installation Industrial Ethernet Rail Switch SPIDER 5TX PD EEC SPIDER 1TX/1FX-MM PD EEC SPIDER 1TX/1FX-SM PD EEC Release 01 06/2012 Technical Support https://hirschmann-support.belden.eu.com

More information

User Manual. Installation Industrial Ethernet Rail Switch SPIDER PD SPIDER 1TX/1FX-SM PD EEC. Installation SPIDER PD Release 02 06/13

User Manual. Installation Industrial Ethernet Rail Switch SPIDER PD SPIDER 1TX/1FX-SM PD EEC. Installation SPIDER PD Release 02 06/13 User Manual Installation Industrial Ethernet Rail Switch SPIDER PD SPIDER 5TX PD EEC SPIDER 1TX/1FX-MM PD EEC SPIDER 1TX/1FX-SM PD EEC Release 02 06/13 Technische Unterstützung https://hirschmann-support.belden.eu.com

More information

Mounting Instruction. Industrial Ethernet Workgroup Switch MACH104 Full Gigabit Family. Mounting Instruction MACH104 Release 07 07/2014

Mounting Instruction. Industrial Ethernet Workgroup Switch MACH104 Full Gigabit Family. Mounting Instruction MACH104 Release 07 07/2014 Mounting Instruction Industrial Ethernet Workgroup Switch MACH104 Full Gigabit Family RM Sb MACH104-20TX-F USB V.24 1 3 5 7 9 11 13 15 17 19 21 23 Aufkleber MAC-Adresse P 2 4 6 8 10 12 14 16 18 20 22 24

More information

User Manual. Installation Industrial Ethernet Rail Switch SPIDER Standard Line. Installation SPIDER-SL Release 05 08/2016

User Manual. Installation Industrial Ethernet Rail Switch SPIDER Standard Line. Installation SPIDER-SL Release 05 08/2016 User Manual Installation Industrial Ethernet Rail Switch SPIDER Standard Line Release 05 08/2016 Technical support https://hirschmann-support.belden.eu.com The naming of copyrighted trademarks in this

More information

User Manual. Installation PoE Injector SPIDER Giga 2TX PoE EEC. Installation PoE Injector Release 01 01/2014

User Manual. Installation PoE Injector SPIDER Giga 2TX PoE EEC. Installation PoE Injector Release 01 01/2014 User Manual Installation PoE Injector SPIDER Giga 2TX PoE EEC Release 01 01/2014 Technical support https://hirschmann-support.belden.eu.com The naming of copyrighted trademarks in this manual, even when

More information

User Manual. Installation Industrial Security Router EAGLE20/30. Installation EAGLE20/30 Release 07 06/2014

User Manual. Installation Industrial Security Router EAGLE20/30. Installation EAGLE20/30 Release 07 06/2014 User Manual Installation Industrial Security Router EAGLE20/30 Release 07 06/2014 Technical support https://hirschmann-support.belden.eu.com The naming of copyrighted trademarks in this manual, even when

More information

User Manual. Installation Industrial Ethernet Ruggedized Switch MACH 1040 Family Full Gigabit MAR1040 MAR1042 MAR1140 MAR1142 MAR1140, MAR1142

User Manual. Installation Industrial Ethernet Ruggedized Switch MACH 1040 Family Full Gigabit MAR1040 MAR1042 MAR1140 MAR1142 MAR1140, MAR1142 User Manual Installation Industrial Ethernet Ruggedized Switch Family Full Gigabit 1 3 5 7 9 11 13 15 FAULT RM Sb MA040 USB V.24 Aufkleber MAC-Adresse P 2 4 6 8 10 12 14 16 MA040 1 P 3 5 7 9 11 13 15 FAULT

More information

User Manual. Installation Industrial ETHERNET Rail Switch SPIDER II, SPIDER II Giga, SPIDER II PoE. Technical Support

User Manual. Installation Industrial ETHERNET Rail Switch SPIDER II, SPIDER II Giga, SPIDER II PoE. Technical Support User Manual Installation Industrial ETHERNET Rail Switch, Giga, PoE P 1 2 3 4 5 6 7 8 8TX 8TX EEC 8TX/1FX EEC 8TX/1FX-SM EEC 8TX/2FX EEC 8TX/2FX-SM EEC 8TX PoE 8TX/1FX-ST EEC 8TX/2FX-ST EEC Giga 5T/2S

More information

User Manual. Installation Industrial Ethernet Workgroup Switch MACH102 Family MACH 102-8TP-F MACH TP-F MACH 102-8TP + M1-8TP-RJ45 + M1-8MM-SXC

User Manual. Installation Industrial Ethernet Workgroup Switch MACH102 Family MACH 102-8TP-F MACH TP-F MACH 102-8TP + M1-8TP-RJ45 + M1-8MM-SXC User Manual Installation Industrial Ethernet Workgroup Switch MACH102 Family MACH 102-8TP-F MACH 102-24TP-F MACH 102-8TP + M1-8TP-RJ45 + M1-8MM-SXC MACH 102-8TP + M1-8SM-SXC + M1-8SFP Release 06 09/2014

More information

User Manual. Installation Industrial ETHERNET Ruggedized Switch MACH 1000 Family MACH 1020 MACH 1030 MACH 1032 MACH 1132 MACH 1000

User Manual. Installation Industrial ETHERNET Ruggedized Switch MACH 1000 Family MACH 1020 MACH 1030 MACH 1032 MACH 1132 MACH 1000 User Manual Installation Industrial ETHERNET Ruggedized Switch Family USB V.4 3 4 7 8 5 6 9 0 3 4 P RM StandBy R R FAULT MACH 00 5 6 9 0 3 4 7 8 5 6 MACH 00 USB V.4 3 4 7 8 5 6 9 0 3 4 P RM StandBy R R

More information

User Manual. Installation Unmanaged IP54 Switch OCTOPUS OS20/OS24. OCTOPUS OS20/OS24 Unmanaged Release 04 04/2012

User Manual. Installation Unmanaged IP54 Switch OCTOPUS OS20/OS24. OCTOPUS OS20/OS24 Unmanaged Release 04 04/2012 User Manual Installation Unmanaged IP54 Switch OCTOPUS OS20/OS24 x y P1 P2 OCTOPUS OS20 1 6 Unmanaged 2 7 ETHERNET Switch 3 8 4 9 5 10 P 1 2 3 4 5 x y OCTOPUS OS20 6 Unmanaged 7 ETHERNET Switch 8 9 10

More information

User Manual. Installation Industrial Ethernet Rail Switch Power Lite RSPL 20/30. Installation RSPL 20/30 Release 03 12/2012

User Manual. Installation Industrial Ethernet Rail Switch Power Lite RSPL 20/30. Installation RSPL 20/30 Release 03 12/2012 User Manual Installation Industrial Ethernet Rail Switch Power Lite RSPL 20/30 Release 03 12/2012 Technical support https://hirschmann-support.belden.eu.com The naming of copyrighted trademarks in this

More information

User Manual. Installation Industrial Ethernet Rail Switch Power Lite RSPL 20/30. Installation RSPL 20/30 Release 08 08/2014

User Manual. Installation Industrial Ethernet Rail Switch Power Lite RSPL 20/30. Installation RSPL 20/30 Release 08 08/2014 User Manual Installation Industrial Ethernet Rail Switch Power Lite RSPL 20/30 Release 08 08/2014 Technical support https://hirschmann-support.belden.eu.com The naming of copyrighted trademarks in this

More information

Startup instructions. AutoConfiguration Adapter ACA21-USB (EEC) ACA22-USB (EEC) ACA21-M12 (EEC) ACA22-M12 (EEC)

Startup instructions. AutoConfiguration Adapter ACA21-USB (EEC) ACA22-USB (EEC) ACA21-M12 (EEC) ACA22-M12 (EEC) Startup instructions AutoConfiguration Adapter ACA21-USB (EEC) ACA22-USB (EEC) ACA21-M12 (EEC) ACA22-M12 (EEC) Release 02 04/2014 Technical Support https://hirschmann-support.belden.eu.com The naming of

More information

User Manual. Installation GREYHOUND Switch Release 04 05/2017. Technical support

User Manual. Installation GREYHOUND Switch Release 04 05/2017. Technical support User Manual Installation GREYHOUND Switch - GRS 1042/GRS 1142 GREYHOUND Power Supply Unit - GPS 1/GPS 2/GPS 3 GREYHOUND Media Module - GMM 20/30/32/40/42 Release 04 05/2017 Technical support https://hirschmann-support.belden.eu.com

More information

ConneXium. TCSEFEA Tofino Firewall Installation Manual NHA TCSEFEA23F3F22.

ConneXium. TCSEFEA Tofino Firewall Installation Manual NHA TCSEFEA23F3F22. ConneXium TCSEFEA Tofino Firewall Installation Manual TCSEFEA23F3F22 NHA15734.01 www.schneider-electric.com NHA15734-04/2015 Contents About this Manual 4 Key 5 Safety instructions 5 1 Description 10 1.1

More information

User Manual. Installation Industrial Ethernet Firewall EAGLE One. Installation EAGLE One Release 01 10/2013

User Manual. Installation Industrial Ethernet Firewall EAGLE One. Installation EAGLE One Release 01 10/2013 User Manual Installation Industrial Ethernet Firewall EAGLE One Release 01 10/2013 Technical support https://hirschmann-support.belden.eu.com The naming of copyrighted trademarks in this manual, even when

More information

User Manual. Installation Industrial Ethernet Rail Switch Power Smart RSPS 20/25. Installation RSPS 20/25 Release 08 08/2014

User Manual. Installation Industrial Ethernet Rail Switch Power Smart RSPS 20/25. Installation RSPS 20/25 Release 08 08/2014 User Manual Installation Industrial Ethernet Rail Switch Power Smart RSPS 20/25 Release 08 08/2014 Technical support https://hirschmann-support.belden.eu.com The naming of copyrighted trademarks in this

More information

FL MC 2000T. Fiber optic converter for 10/100Base-Tx to single- or multi-mode fiberglass with SC-duplex and ST connections. Data sheet 3379_en_B

FL MC 2000T. Fiber optic converter for 10/100Base-Tx to single- or multi-mode fiberglass with SC-duplex and ST connections. Data sheet 3379_en_B Fiber optic converter for 10/100Base-Tx to single- or multi-mode fiberglass with SC-duplex and ST connections Data sheet 3379_en_B 1 Description PHOENIX CONTACT 2015-07-14 2 Features Media converters provide

More information

User Manual. Installation Industrial Ethernet Rail Switch Power RSP 20/25/30/35 RSP 20/25/30/35

User Manual. Installation Industrial Ethernet Rail Switch Power RSP 20/25/30/35 RSP 20/25/30/35 User Manual Installation Industrial Ethernet Rail Switch Power Release 02 03/2012 Technical Support https://hirschmann-support.belden.eu.com The naming of copyrighted trademarks in this manual, even when

More information

User Manual. Installation Industrial Ethernet Ruggedized Switch MACH 1040 Family Full Gigabit MAR1040 MAR1042 MAR1140 MAR1142 MAR1140, MAR1142

User Manual. Installation Industrial Ethernet Ruggedized Switch MACH 1040 Family Full Gigabit MAR1040 MAR1042 MAR1140 MAR1142 MAR1140, MAR1142 User Manual Installation Industrial Ethernet Ruggedized Switch MACH 1040 Family Full Gigabit 1 3 5 7 9 11 13 15 FAULT RM Sb R1 MAR1040 USB V.24 Aufkleber MAC-Adresse P R2 2 4 6 8 10 12 14 16 MAR1040 1

More information

User Manual. Installation Industrial Security Router EAGLE20/30. Installation EAGLE20/30 Release 05 10/2013

User Manual. Installation Industrial Security Router EAGLE20/30. Installation EAGLE20/30 Release 05 10/2013 User Manual Installation Industrial Security Router EAGLE20/30 EAGLE30-0402... EAGLE20-0400... Release 05 10/2013 Technical support https://hirschmann-support.belden.eu.com The naming of copyrighted trademarks

More information

4 10/100/1000T Mini-GBIC with 4 IEEE 802.3at High Power PoE Industrial Wide Temperature Switch. User Manual SISTP LRT

4 10/100/1000T Mini-GBIC with 4 IEEE 802.3at High Power PoE Industrial Wide Temperature Switch. User Manual SISTP LRT 4 10/100/1000T + 2 1000 Mini-GBIC with 4 IEEE 802.3at High Power PoE Industrial Wide Temperature Switch User Manual V1.0 September-2013 FCC Warning This Equipment has been tested and found to comply with

More information

FL MC 2000E (SM40) LC

FL MC 2000E (SM40) LC IEC 61850 fiber optic converter with LC fiber optic connection (1310 nm) to convert 100Base-Tx to single- or multi-mode fiber glass Data sheet 3205_en_C 1 Description PHOENIX CONTACT 2014-04-04 2 Features

More information

Industrial 5-Port Fast Ethernet Switches with SFP Slot and optional 4 PoE PSE Ports. Basic Model: KSD-541 PoE Model: KSD-541-P. Installation Guide

Industrial 5-Port Fast Ethernet Switches with SFP Slot and optional 4 PoE PSE Ports. Basic Model: KSD-541 PoE Model: KSD-541-P. Installation Guide Industrial 5-Port Fast Ethernet Switches with SFP Slot and optional 4 PoE PSE Ports Basic Model: KSD-541 PoE Model: KSD-541-P Installation Guide DOC.080104-1- (C) 2008 KTI Networks Inc. All rights reserved.

More information

Redundancy unit CP-A RU

Redundancy unit CP-A RU 2CDC 271 010 F0t06 Features Decoupling of CP power supply units with 2 inputs, each up to 20 A per input / channel Output up to 40 A True redundancy by 100 % decoupling of two parallel connected power

More information

PHOENIX CONTACT - 07/2006

PHOENIX CONTACT - 07/2006 Buffer module with maintenance-free capacitor-based power storage device INTERFACE Data sheet 102035_03_en PHOENIX CONTACT - 07/2006 Description Short-term mains interruptions are bridged by QUINT BUFFER,

More information

Description and Assembly Instructions

Description and Assembly Instructions Description and Assembly Instructions Modular Industrial Patch Panel Release 01 12/11 Technical Support HAC.Support@Belden.com The naming of copyrighted trademarks in this manual, even when not specially

More information

Industrial 5-Port Fast Ethernet Switches. with SFP Slot and optional 4 PoE PSE Ports. Basic Model: KSD-541. PoE Model: KSD-541-HP. Installation Guide

Industrial 5-Port Fast Ethernet Switches. with SFP Slot and optional 4 PoE PSE Ports. Basic Model: KSD-541. PoE Model: KSD-541-HP. Installation Guide Industrial 5-Port Fast Ethernet Switches with SFP Slot and optional 4 PoE PSE Ports Basic Model: KSD-541 PoE Model: KSD-541-HP Installation Guide DOC.141201-1- (C) 2014 KTI Networks Inc. All rights reserved.

More information

Operating Manual UMB ISO Converter ISOCON Order Number: 8160.UISO

Operating Manual UMB ISO Converter ISOCON Order Number: 8160.UISO Order Number: 8160.UISO Status: V3; 17.09.2010c G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany 1 TABLE OF CONTENTS PLEASE READ BEFORE USE... 3 DESCRIPTION... 5 UMB ISO CONVERTER ISOCON... 6 CONFIGURATION...

More information

Operating instructions. Switching amplifier DN0210 DN / / 2015

Operating instructions. Switching amplifier DN0210 DN / / 2015 Operating instructions Switching amplifier DN0210 DN0220 UK 80011079 / 00 01 / 2015 Contents 1 Preliminary note...4 1.1 Symbols used...4 1.2 Warning signs used...4 2 Safety instructions...5 2.1 General...5

More information

EDR-G902/G903 Quick Installation Guide

EDR-G902/G903 Quick Installation Guide EDR-G902/G903 Quick Installation Guide Moxa EtherDevice Router Edition 4.0, March 2016 Technical Support Contact Information www.moxa.com/support Moxa Americas: Toll-free: 1-888-669-2872 Tel: 1-714-528-6777

More information

Operating instructions. Speed monitor D / / 2014

Operating instructions. Speed monitor D / / 2014 Operating instructions Speed monitor D200 80005257 / 00 05 / 2014 Contents 1 Preliminary note...4 1.1 Symbols used...4 1.2 Warning signs used...4 2 Safety instructions...5 2.1 General...5 2.2 Target group...5

More information

Industriefunkuhren. Technical Manual. Signal Converter. for DIN Rail Mounting Series 4800xx-yy ENGLISH

Industriefunkuhren. Technical Manual. Signal Converter. for DIN Rail Mounting Series 4800xx-yy ENGLISH Industriefunkuhren Technical Manual Signal Converter for DIN Rail Mounting Series 4800xx-yy ENGLISH Version: 01.01-19.07.2007 2 / 23 Signal Converter 4800 - V01.01 INPORTANT NOTES Downloading Technical

More information

Rhino Buffer Module PSM24-BFM600S. Operating Instructions

Rhino Buffer Module PSM24-BFM600S. Operating Instructions Rhino Buffer Module PSM24-BFM600S Operating Instructions RHINO BUFFER MODULE PSM24-BFM600S Description The PSM24-BFM600S Buffer Module will hold the output voltage of a 24 VDC power supply after brownouts

More information

Power supply module, bus connection module

Power supply module, bus connection module s 8 183 8183p01, p02 TX-I/O Power supply module, bus connection module TXS1.12F10 TXS1.EF10 Each I/O row begins with one of these devices TXS1.12F10 power supply module Up to 4 power supply modules can

More information

TRIO-DIODE/12-24DC/2X10/1X20

TRIO-DIODE/12-24DC/2X10/1X20 Redundancy module INTERFACE Data sheet 104278_en_00 1 Description PHOENIX CONTACT 20100423 Features TRIO DIODE is the DINrail mountable redundancy module from the TRIO POWER product range. Using the redundancy

More information

QUINT-BUFFER/24DC/24DC/40

QUINT-BUFFER/24DC/24DC/40 Buffer module Data sheet 105496_en_01 PHOENIX CONTACT 2013-11-01 1 Description The QUINT BUFFER buffer module combines the electronic switchover unit and power storage in the same housing. The buffer module

More information

Rhino Redundancy Module PSM24-REM360S. Operating Instructions

Rhino Redundancy Module PSM24-REM360S. Operating Instructions Rhino Redundancy Module PSM4-REM360S Operating Instructions RHINO REDUNDANCY MODULE PSM4-REM360S Description With this module and two power supplies of the PSM series (78, 90, 56, 80 and 360 watt models),

More information

REDUNDANCY MODULE TSP-REM360 AND TSP-REM600

REDUNDANCY MODULE TSP-REM360 AND TSP-REM600 REDUNDANCY MODULE TSP-REM360 AND TSP-REM600 Operating Instructions Seite 1 Dimensions drawings: TSP-REM360 Weight: 0.882lb Gewicht: 0.40kg Seite 2 Dimensions drawings: TSP-REM600 Bottom view Top view Side

More information

Operating instructions AS-i SmartLine module AC3200 AC /00 06/2016

Operating instructions AS-i SmartLine module AC3200 AC /00 06/2016 Operating instructions AS-i SmartLine module AC3200 AC3201 80237876/00 06/2016 Contents 1 Preliminary note...3 1.1 Symbols used...3 1.2 Warnings used...3 2 Safety instructions...3 2.1 General...3 2.2 Target

More information

User Manual. Installation Industrial ETHERNET Workgroup Switch MACH104 Family Full Gigabit. MACH104 Release 02 12/10

User Manual. Installation Industrial ETHERNET Workgroup Switch MACH104 Family Full Gigabit. MACH104 Release 02 12/10 User Manual Installation Industrial ETHERNET Workgroup Switch Family Full Gigabit RM Sb -20TX-F USB V.24 1 3 5 7 9 11 13 15 17 19 21 23 Aufkleber MAC-Adresse P 2 4 6 8 10 12 14 16 18 20 22 24-20TX-F RM

More information

CMU 100 RS232 to Singlemode Fiber Optic Converter User Manual

CMU 100 RS232 to Singlemode Fiber Optic Converter User Manual CMU 100 RS232 to Singlemode Fiber Optic Converter User Manual CMU 100 / 1.1.S - 0 CMU 100 / 7.1.S - 0 Company: Device: Document: Code: Version: Date: Ediseja 21 CMU 100 / 1.1.S - 0 User manual CMUMU11S

More information

Installation Ruggedized ABB FOX Switch AFS650 / 655

Installation Ruggedized ABB FOX Switch AFS650 / 655 ABB Power Systems Installation Ruggedized ABB FOX Switch AFS650 / 655 User Manual Power and productivity for a better world TM User Manual - Installation Ruggedized ABB FOX Switch AFS650 / 655 Copyright

More information

MINI-PS AC/10-15DC/8

MINI-PS AC/10-15DC/8 Primary-Switched Power Supply, Narrow Design Data Sheet 08/2004 MINI POWER provides: An extra narrow design, with widths of 22.5 mm, 45 mm, and 67.5 mm (0.886, 1.772, and 2.657 in.) Global use due to a

More information

Description and operating instructions i Rail Switch 2 RS2-5TX RS2-5TX/FX Order No. Order No.

Description and operating instructions i Rail Switch 2 RS2-5TX RS2-5TX/FX Order No. Order No. Description and operating instructions i Rail Switch 2 Order No. 943 732-00 /FX Order No. 943 732-0 The Rail Switches and /FX have been especially designed for use in industrial environments. They support

More information

Hypercable injecteur HPOE - Industrial IEEE 802.3at Gigabit PoE Injector. User Manual. v.1.0 Jun Mail :

Hypercable injecteur HPOE -  Industrial IEEE 802.3at Gigabit PoE Injector. User Manual. v.1.0 Jun Mail : Industrial IEEE 802.3at Gigabit PoE Injector User Manual v.1.0 Jun-2011 FCC Warning This Equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15

More information

Device Server for the conversion of serial interfaces (RS-232/422/485) to IP.

Device Server for the conversion of serial interfaces (RS-232/422/485) to IP. Manual Entry Line Industrial Gigabit Ethernet Switch 4x 10/100/1000Base-T, 1x SFP Ports MICROSENS General The IP protocol has already left the in-house environment and is going to take all remaining communication

More information

Fig. 1: Entry Line Compact Gigabit Ethernet Converter

Fig. 1: Entry Line Compact Gigabit Ethernet Converter Entry Line Compact Industrial Fast/Gigabit Ethernet Converter 1x 100/1000Base-T 1x 100/1000Base-X (SFP Slot) MICROSENS General The IP protocol has already left the in-house environment and is going to

More information

RXM39.1. PL-Link IO Block. Desigo TRA. Use with PXC3 series room automation station

RXM39.1. PL-Link IO Block. Desigo TRA. Use with PXC3 series room automation station s 3 836 3836P01 Desigo TRA PL-Link IO Block Use with PXC3 series room automation station RXM39.1 The PL-Link IO Block contains the inputs and outputs controlled by a room automation station via PL-Link.

More information

CMU 100 Multimode Fiber Optic to Singlemode Fiber Optic Converter User Manual

CMU 100 Multimode Fiber Optic to Singlemode Fiber Optic Converter User Manual CMU 100 Multimode Fiber Optic to Singlemode Fiber Optic Converter User Manual CMU 100 / 1.6.S - 0 CMU 100 / 7.6.S - 0 Company: Device: Document: Code: Version: Date: Ediseja 21 CMU 100 / 1.6.S - 0 User

More information

User Manual. Installation Industrial Ethernet Firewall EAGLE One. Installation EAGLE One Release 05 04/2015

User Manual. Installation Industrial Ethernet Firewall EAGLE One. Installation EAGLE One Release 05 04/2015 User Manual Installation Industrial Ethernet Firewall EAGLE One Release 05 04/2015 Technical support https://hirschmann-support.belden.eu.com The naming of copyrighted trademarks in this manual, even when

More information

EZ864 G. Telit Cellular GSM/UMTS Engine. Hardware guide Version: Update: 27. APR.2009 EZ864 G_Hardware Guide_V

EZ864 G. Telit Cellular GSM/UMTS Engine. Hardware guide Version: Update: 27. APR.2009 EZ864 G_Hardware Guide_V EZ864 G Telit Cellular GSM/UMTS Engine Hardware guide Version: 04.01 Update: 27. APR.2009 EZ864 G_Hardware Guide_V4. - 1 - Hardware Interface Description 1. Hardware Features of the EZ864 G Feature Implementation

More information

CMU 100 RS485 to 7x, 6x, 5x, 4x Multimode Fiber Optic Star Coupler User Manual

CMU 100 RS485 to 7x, 6x, 5x, 4x Multimode Fiber Optic Star Coupler User Manual CMU 100 RS485 to 7x, 6x, 5x, 4x Multimode Fiber Optic Star Coupler User Manual CMU 100 / 2.5.6.6.6.6.6.6.6 12, CMU 100 / 8.5.6.6.6.6.6.6.6 12, CMU 100 / 2.5.6.6.6.6.6.6 12, CMU 100 / 8.5.6.6.6.6.6.6 12,

More information

User Manual. Installation MICE Switch Power MSP30/32 MSP30/MSP MSP30/MSP MSP30/MSP

User Manual. Installation MICE Switch Power MSP30/32 MSP30/MSP MSP30/MSP MSP30/MSP User Manual Installation MICE Switch Power MSP30/32 MSP30/MSP32-0804... MSP30/MSP32-1604... MSP30/MSP32-2404... Release 06 04/2015 Technical Support https://hirschmann-support.belden.eu.com The naming

More information

SINAMICS G130. Terminal Module 150 (TM150) Operating Instructions 03/2013 SINAMICS

SINAMICS G130. Terminal Module 150 (TM150) Operating Instructions 03/2013 SINAMICS SINAMICS G130 Operating Instructions 03/2013 SINAMICS s Safety information 1 General information 2 SINAMICS SINAMICS G130 Mechanical installation 3 Electrical installation 4 Technical specifications 5

More information

User Manual. Redundancy Configuration Industrial ETHERNET (Gigabit-)Switch RS20/RS30/RS40, MS20/MS30. UM RedundConfig L2E Release 9.

User Manual. Redundancy Configuration Industrial ETHERNET (Gigabit-)Switch RS20/RS30/RS40, MS20/MS30. UM RedundConfig L2E Release 9. User Manual Redundancy Configuration Industrial ETHERNET (Gigabit-)Switch RS20/RS30/RS40, MS20/MS30 Technical Support https://hirschmann-support.belden.eu.com The naming of copyrighted trademarks in this

More information

Installation and Operation Back-UPS BR1000G-IN / BR1500G-IN

Installation and Operation Back-UPS BR1000G-IN / BR1500G-IN Installation and Operation Back-UPS BR1000G-IN / BR1500G-IN Important Safety Information Read the instructions carefully to become familiar with the equipment before trying to install, operate, service

More information

General. 5 and 8 port Fast Ethernet switches. 6 and 8 Port Gigabit Ethernet switches. Switches with fiber uplink

General. 5 and 8 port Fast Ethernet switches. 6 and 8 Port Gigabit Ethernet switches. Switches with fiber uplink Entry Line Industrial Gigabit Ethernet Switch 4x 10/100/1000Base-T with PoE+, 1x 10/100/1000Base-T or 100/1000Base-X Combo Port, 1x 100/1000Base X SFP Slot General The IP protocol has already left the

More information

Installation Industrial ETHERNET Rail Switch RS20/RS22/RS30/RS32/RS40 Family RPS90/48V HV -/N +/L FAULT RM U: 110 / 230 VAC U: 60 / 250 VDC 48-54V

Installation Industrial ETHERNET Rail Switch RS20/RS22/RS30/RS32/RS40 Family RPS90/48V HV -/N +/L FAULT RM U: 110 / 230 VAC U: 60 / 250 VDC 48-54V User Manual Installation Industrial ETHERNET Rail Switch RS0/RS/RS0/RS/RS0 Family +V() 0V 0V RS0 +V() RS +V() 0V 0V +V() RS90/V HV +V() 0V 0V RS0 +V() -/N +/L U: 0 / 0 VAC U: 0 / 0 VDC I-ADDRESS V. GB

More information

Operating instructions. Standstill monitor A / / 2011

Operating instructions. Standstill monitor A / / 2011 Operating instructions Standstill monitor A300 UK 1 2 3 4 5 6 7 8 7390337 / 01 02 / 2011 1 2 3 4 5 6 7 8 switchpoint min max pulse/min power Made in Germany ifm electronic gmbh D 45127 Essen func. I II

More information

Redundancy Module QUINT-DIODE/40

Redundancy Module QUINT-DIODE/40 Redundancy Module QUT DIODE provides: 00% decoupling of power supplies connected in parallel Can be installed in potentially explosive areas Load currents up to 60 A supported Easy assembly by snapping

More information

PHOENIX CONTACT - 01/2010. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

PHOENIX CONTACT - 01/2010. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area. Uninterruptible power supply with integrated power supply unit INTERFACE Data sheet 104211_en_00 1 Description PHOENIX CONTACT - 01/2010 Features The MINI-DC-UPS provide an uninterruptible DC voltage both

More information

EDS-G205A-4PoE Hardware Installation Guide

EDS-G205A-4PoE Hardware Installation Guide EDS-G205A-4PoE Hardware Installation Guide Moxa EtherDevice Switch First Edition, October 2011 2011 Moxa Inc. All rights reserved. P/N: 1802002051020 Overview The EDS-G205A-4PoE series industrial Ethernet

More information

Installation Industrial ETHERNET Rail Switch RS20/RS22/RS30/RS32/RS40 Family RPS90/48V HV -/N +/L FAULT RM U: 110 / 230 VAC U: 60 / 250 VDC 48-54V

Installation Industrial ETHERNET Rail Switch RS20/RS22/RS30/RS32/RS40 Family RPS90/48V HV -/N +/L FAULT RM U: 110 / 230 VAC U: 60 / 250 VDC 48-54V User Manual Installation Industrial ETHERNET Rail Switch RS0/RS/RS0/RS/RS0 Family +V() 0V 0V RS0 +V() RS +V() 0V 0V +V() RS90/V HV +V() 0V 0V +V() RS0 -/N +/L U: 0 / 0 VAC U: 0 / 0 VDC I-ADDRESS V. GB

More information

User Manual. Redundancy Configuration Industrial ETHERNET (Gigabit) Switch RS20/RS30/RS40, MS20/MS30, OCTOPUS. UM Redundancy L2E Release 7.

User Manual. Redundancy Configuration Industrial ETHERNET (Gigabit) Switch RS20/RS30/RS40, MS20/MS30, OCTOPUS. UM Redundancy L2E Release 7. User Manual Redundancy Configuration Industrial ETHERNET (Gigabit) Switch RS20/RS30/RS40, MS20/MS30, OCTOPUS Technical Support HAC.Support@Belden.com The naming of copyrighted trademarks in this manual,

More information

Serial PROFIBUS Interface

Serial PROFIBUS Interface Installation Manual Serial PROFIBUS Interface Version: EN-062016-2.3 Copyright 2016 Softing Industrial Automation GmbH Disclaimer of liability The information contained in these instructions corresponds

More information

Type ME43. Quickstart

Type ME43. Quickstart Type ME43 Fieldbus gateway büs to Industrial Ethernet, PROFIBUS DPV1, CC-Link Feldbus-Gateway büs zu Industrial Ethernet, PROFIBUS DPV1, CC-Link Passerelle bus de terrain büs vers Ethernet industriel,

More information

Entry Line Industrial Gigabit Ethernet Bridging Converter, PoE+ optional 1x 10/100/1000Base-T, 1x 100/1000 SFP

Entry Line Industrial Gigabit Ethernet Bridging Converter, PoE+ optional 1x 10/100/1000Base-T, 1x 100/1000 SFP Entry Line Industrial Gigabit Ethernet Bridging Converter, PoE+ optional 1x 10/100/1000Base-T, 1x 100/1000 SFP General The IP protocol has already left the in-house environment and is going to take all

More information

Digital ac/dc (24V) Input Module

Digital ac/dc (24V) Input Module Installation Instructions Digital ac/dc (24V) Input Module Catalog Number 1771-IND, Series C Topic Page Important User Information 2 Before You Begin 3 Power Requirements 3 Prevent Electrostatic Discharge

More information

BACnet/IP Web Interface

BACnet/IP Web Interface Desigo Control Point BACnet/IP Web Interface PXG3.W100-1, PXG3.W200-1 Web-based, graphical operation of BACnet automation stations using Desigo touch panels and devices with an HTML 5.0 web browser. Simultaneous

More information

Installation Job Aid for VSP 4450GTX-HT- PWR+

Installation Job Aid for VSP 4450GTX-HT- PWR+ Installation Job Aid for VSP 4450GTX-HT- PWR+ Notices Release 6.1.0.0 NN46251-305 Issue 02.01 November 2017 Notice paragraphs alert you about issues that require your attention. The following paragraphs

More information

EDR-810 Series Quick Installation Guide

EDR-810 Series Quick Installation Guide EDR-810 Series Quick Installation Guide Moxa Industrial Secure Router Edition 4.0, May 2018 Technical Support Contact Information www.moxa.com/support Moxa Americas: Toll-free: 1-888-669-2872 Tel: 1-714-528-6777

More information

M-bus web server. Meters and Energy Cost Allocation WTV676-HB6035

M-bus web server. Meters and Energy Cost Allocation WTV676-HB6035 Meters and Energy Cost Allocation M-bus web server WTV676-HB6035 The web server reads out wireless or wired M-bus devices over Ethernet or the Internet using a browser. Power and connection for up to 20

More information

PHOENIX CONTACT - 08/2009. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

PHOENIX CONTACT - 08/2009. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area. Primary-switched power supply for building automation INTERFACE Data sheet 103505_en_02 1 Description PHOENIX CONTACT - 08/2009 Features STEP POWER power supply units for building automation The new STEP

More information

PHOENIX CONTACT - 06/2007. DANGER OF EXPLOSION! Remove an item only when it is not connected to power or if it is located in the non-explosive area.

PHOENIX CONTACT - 06/2007. DANGER OF EXPLOSION! Remove an item only when it is not connected to power or if it is located in the non-explosive area. Primary switched power supply, 3-phase, output current: 40 A INTERFACE Data Sheet 102782_01_en PHOENIX CONTACT - 06/2007 Description TRIO POWER is the rail mountable 24 V power supply unit with basic functions.

More information

Installation Job Aid for VSP 4850GTS

Installation Job Aid for VSP 4850GTS Installation Job Aid for VSP 4850GTS Notices Release 6.1.0.0 NN46251-308 Issue 02.01 November 2017 Notice paragraphs alert you about issues that require your attention. The following paragraphs describe

More information

Hardware Installation Manual

Hardware Installation Manual Hardware Installation Manual Tofino Xenon Security Appliance Release 01 05/2014 Technical Support www.tofinosecurity.com/support The naming of copyrighted trademarks in this manual, even when not specially

More information

R70 Ethernet to CAN interface Manual (1.4 EN)

R70 Ethernet to CAN interface Manual (1.4 EN) R70 Ethernet to CAN interface Manual (1.4 EN) General information R70 Ethernet to CAN interface Manual Version 1.4 EN, 04/2009, DOC01816 Copyright 2009 by d&b audiotechnik GmbH; all rights reserved. d&b

More information

User Manual. Installation Industrial ETHERNET Switch MICE MS20/MS30. MICE MS20/MS30 Release 01/09. Technical Support

User Manual. Installation Industrial ETHERNET Switch MICE MS20/MS30. MICE MS20/MS30 Release 01/09. Technical Support User Manual Installation Industrial ETHERNET Switch MICE MICE MS20 MICE MS30 MICE Release 01/09 Technical Support HAC-Support@hirschmann.de The naming of copyrighted trademarks in this manual, even when

More information

Siemens Spares. Preface 1. Scope of Delivery 2 SIPLUS CMS4000. Product Characteristics 3 ION PROFIBUS DP SPY T001 Installation and Maintenance 4

Siemens Spares. Preface 1. Scope of Delivery 2 SIPLUS CMS4000. Product Characteristics 3 ION PROFIBUS DP SPY T001 Installation and Maintenance 4 Preface 1 Scope of Delivery 2 Product Characteristics 3 Industrial I/O-Node ION PROFIBUS DP SPY T001 Installation and Maintenance 4 6AT8000-1BA00-5XA0 Notes on the CE Mark 5 References 6 Appendix 7 Release

More information

Product and Applications Description

Product and Applications Description IP N146/02 Product and Applications Description The IP N146/02 is a DIN rail mounted device. The device implements the KNXnet/IP standard and connects KNX/EIB lines via data networks using the Internet

More information

2-Port Wireless Access Controller EWS4502. Installation Guide.

2-Port Wireless Access Controller EWS4502. Installation Guide. 2-Port Wireless Access Controller EWS4502 Installation Guide www.edge-core.com Installation Guide EWS4502 Wireless Access Controller with 2 000BASE-T (RJ-45) Ports, E06203-CS-R0 4900000238A How to use

More information

EDS-G205-1GTXSFP Quick Installation Guide

EDS-G205-1GTXSFP Quick Installation Guide EDS-G205-1GTXSFP Quick Installation Guide Moxa EtherDevice Switch Edition 3.0, February 2017 Technical Support Contact Information www.moxa.com/support Moxa Americas: Toll-free: 1-888-669-2872 Tel: 1-714-528-6777

More information

STEP-PS/1AC/24DC/1.75

STEP-PS/1AC/24DC/1.75 Primary-switched power supply, 1 AC, output current 1.75 A INTERFACE Data Sheet 103506_en_00 1 Description PHOENIX CONTACT - 05/2008 Features STEP POWER power supply units for building automation The new

More information

EX-RC1 Remote I/O Adapter

EX-RC1 Remote I/O Adapter EX-RC1 Remote I/O Adapter The EX-RC1 interfaces between Unitronics Vision OPLCs and remote I/O Expansion Modules distributed throughout your system. The adapter is connected to a PLC via CANbus. Each adapter

More information

Square D Clipsal Pascal Automation Controller

Square D Clipsal Pascal Automation Controller Square D Clipsal Pascal Automation Controller SLC5500PACA For Use with Wired C-Bus Networks Instruction Bulletin Retain for future use. Square D Clipsal Pascal Automation Controller 63249-420-258A2 Instruction

More information

TRC-190 User s Manual

TRC-190 User s Manual User s Manual Edition 3.2, May 2017 www.moxa.com/product 2017 Moxa Inc. All rights reserved. User s Manual The software described in this manual is furnished under a license agreement and may be used only

More information

Operating instructions RFID evaluation unit DTE / / 2016

Operating instructions RFID evaluation unit DTE / / 2016 Operating instructions RFID evaluation unit DTE101 80005398 / 01 06 / 2016 Contents 1 Preliminary note...4 1.1 Notes on this document...4 1.2 Symbols used...4 2 Safety instructions...4 2.1 General...4

More information

INDUSTRIAL 1000BASE-T TO 1000BASE-X MEDIA CONVERTERS. KCD-400 Series. Installation Guide

INDUSTRIAL 1000BASE-T TO 1000BASE-X MEDIA CONVERTERS. KCD-400 Series. Installation Guide INDUSTRIAL 1000BASE-T TO 1000BASE-X MEDIA CONVERTERS KCD-400 Series Installation Guide DOC.060227-KCD-400-1- (C) 2005 KTI Networks Inc. All rights reserved. No part of this documentation may be reproduced

More information

Installing and Configuring Rialto Analytic Appliances

Installing and Configuring Rialto Analytic Appliances Installing and Configuring Rialto Analytic Appliances Important Safety Information This manual provides installation and operation information and precautions for the use of this camera. Incorrect installation

More information

EL1142 Series. IEC / IEEE 1613 Hardened 2-Port 10/100BASE-TX to 2-Port 100BASE-FX Media Converter. User s Guide

EL1142 Series. IEC / IEEE 1613 Hardened 2-Port 10/100BASE-TX to 2-Port 100BASE-FX Media Converter. User s Guide EL1142 Series IEC 61850 / IEEE 1613 Hardened 2-Port 10/100BASE-TX to 2-Port 100BASE-FX Media Converter User s Guide All Rights Reserved Dissemination or reproduction of this document, or its contents,

More information

User Manual Entry Line Industrial Fast Ethernet Switch 5x 10/100Base-TX

User Manual Entry Line Industrial Fast Ethernet Switch 5x 10/100Base-TX User Manual Entry Line Industrial Fast Ethernet Switch 5x 10/100Base-TX Entry Line Fast Ethernet Switch Fast Ethernet Switch for Industrial Use Page 2/11 Table of Contents General... 3 Benefits... 3 Front

More information

CMC III Temperature/Humidity Sensor

CMC III Temperature/Humidity Sensor CMC III Temperature/Humidity Sensor DK 7030.111 Assembly and operating instructions Foreword Foreword Dear Customer, Thank you for choosing our CMC III temperature/humidity sensor (referred to hereafter

More information

RTU500 series Data Sheet Power Supply CP-E 24/2.5

RTU500 series Data Sheet Power Supply CP-E 24/2.5 Data Sheet Power Supply CP-E 24/2.5 Power Supply CP-E 24/2.5 Application The primary switch mode power supply offers two voltage input ranges. This enables the supply with AC or DC. Furthermore it is equipped

More information

Omnitron Systems Technology, Inc. 1. iconverter. 19-Module Managed Power Chassis User s Manual

Omnitron Systems Technology, Inc. 1. iconverter. 19-Module Managed Power Chassis User s Manual Omnitron Systems Technology, Inc. 1 iconverter 19-Module Managed Power Chassis User s Manual 27 Mauchly, #201, Irvine, CA 92618 Phone: (949) 250-6510; Fax: (949) 250-6514 2 Omnitron Systems Technology,

More information

10/100/1000T to Mini-GBIC Industrial Switch Converter 10/100/1000T to 1000SX/LX Industrial Switch Converter. AMG9011G-H (-40 to 75C) User Manual

10/100/1000T to Mini-GBIC Industrial Switch Converter 10/100/1000T to 1000SX/LX Industrial Switch Converter. AMG9011G-H (-40 to 75C) User Manual 10/100/1000T to Mini-GBIC Industrial Switch Converter 10/100/1000T to 1000SX/LX Industrial Switch Converter AMG9011G-H (-40 to 75C) User Manual www.amgsystems.com Content Overview...1 Introduction... 1

More information

Operating and mounting instructions

Operating and mounting instructions General Usage IPAS DALI Gateways bring together the crossfunctional KNX installation bus and the lighting control specific DALI-Bus (IEC 60929). Lights with cost-effective, digital DALI ECGs can therefore

More information

Lantech. IPGS-0204DSFP 4 10/100/1000T PoE at/af + 2 Dual Speed SFP Industrial Unmanaged Switch

Lantech. IPGS-0204DSFP 4 10/100/1000T PoE at/af + 2 Dual Speed SFP Industrial Unmanaged Switch Lantech IPGS-0204DSFP 4 10/100/1000T PoE at/af + 2 Dual Speed SFP Industrial Unmanaged Switch IGS-0204DSFP 4 10/100/1000T + 2 Dual Speed SFP Industrial Unmanaged Switch User Manual V1.00 Jul-2016 Content

More information

Multi-Power Miniature Media Converter 10/100/1000 JUNE 2007 LGC322A-NPS LGC320A-NPS, LGC321A-NPS,

Multi-Power Miniature Media Converter 10/100/1000 JUNE 2007 LGC322A-NPS LGC320A-NPS, LGC321A-NPS, Copyright 2006. Black Box Corporation. All rights reserved 1000 Park Drive * Lawrence, PA. 35055-1018 * 724-746-5500 * Fax 724-746-0746 56-80830BB-00 Rev A1 June 2007 JUNE 2007 LGC320A, LGC321A, LGC322A,

More information