1 M2500 Engine Controller Configuration Manual Revision: Page 1

2 Contents 1 Preface Configuration from front panel Engine Controller Configuration RPM settings Stop Settings Run/ Stop Solenoid Settings Pre-lubrication Starter engagement protection Service indication Service interval Analogue input configuration Text Unit Cable monitoring enabled Scale, min Scale, max Show decimal Digital Input configuration Text Cable monitoring J1939 input configuration Alarm configuration Text Enabled Alarm type Auto reset Monitoring Delay Input Output Functions Siren Reset Alarm Reset Dashboard configuration Device name Oil Inp. Src (Engine oil pressure gauge) Water inp. Src (Engine coolant water temperature gauge) Modbus configuration Display and LED configuration Time and date Password configuration Firmware update from SD card Revision: Page 2

3 2.13 Save configuration to SD card Load configuration from SD card Reset all settings to default values About (SW Revision) Language configuration Automatic configuration update from SD Configuration via PC (USB) Connecting to a PC Description of the configuration tool Saving of changes in the configuration Save all Reset Page Revert Page Engine Controller Tab Digital Inputs Tab Analogue Inputs Tab Alarms Tab Output Functions Tab General Parameters Tab Communication Tab Service Indication Tab Revision: Page 3

4 1 Preface The M Engine Controller is designed for control and monitoring of marine engines. Together with the optional M Shutdown Unit the M Engine Controller forms a complete alarm, control and protective safety system for marine engines. Typical applications are marine generator engines such as auxiliary generators, emergency generators, harbour generators and propulsion engines. The unit is designed for assembly in the main switchboard or at the engine. This manual describes the configuration of M2500. Revision: Page 4

5 2 Configuration from front panel Enter the configuration mode by pressing button. Now the user is prompted for a configuration pin code. Once a valid pin code has been entered, configuration of the M2500 is allowed: Note: The factory default configuration pin code is The pin code can be changed from within the configuration area. Note: The changes made to the configuration, are only applied when the configuration area is exited. Revision: Page 5

6 2.1 Engine Controller Configuration The Engine Controller Configuration menu includes following settings: RPM settings Choice and shift between settings by use of cursor keys. Move cursor to Save & Exit and press ENTER in order to accept a change. Press ESC in order to discard a change. Revision: Page 6

7 RPM Source With this parameter the source for the speed detection is selected. It can be either a pick-up (magnetic, PNP or NPN, to be selected on DIP switches on the rear of the unit as described in the installation manual), from the J1939 bus or from an external tacho relay (connected as normally open contacts on terminal 11 for crank disconnect speed) Flywheel teeth count Here the number of teeth on the flywheel is configured. This setting is only relevant when the RPM source is set to Pick Up Nominal RPM When using a pick up or the J1939 bus for the speed detection the nominal speed of the engine must be configured. The crank disconnect and overspeed limits refer to the nominal speed setting Crank Disconnect RPM The crank disconnect rpm is the ignition speed of the engine, at which the starter is disengaged. This setting is only relevant if the speed is detected by pick up or J1939 bus. The crank disconnect speed is expressed as a percentage of the nominal speed Overspeed RPM If the overspeed limit is exceeded the M2500 will issue a shutdown command instantaneously. This shutdown is always monitored regardless if engine is running or not and cannot be overridden. This setting is only relevant if the speed is detected by pick up or J1939 bus. The over speed limit is expressed as a percentage of the nominal speed Tacho failure output If the M2500 loses the speed signal during operation, a tacho fail alarm will be issued. This alarm can be configured to trigger any of the programmable outputs Start sequence settings Start delay The start delay is the delay between activation of the remote start input and start of cranking. During the start delay the Start Warning output (terminal 37) is activated. This output can be used for connection of a horn for start warning, the pre-glow function for the engine or for energizing the engine ECU. The start delay is expressed in seconds. Revision: Page 7

8 Crank time Configuration of the crank time during each start attempt. The crank time is expressed in seconds Rest time Configuration of the rest time between start attempts. The rest time is expressed in seconds Monitoring delay Condition for the start of monitoring is detection of crank disconnect speed (ignition speed) and expiration of the monitoring delay time after detection of crank disconnect speed. The monitoring delay is expressed in seconds Auto start attempts In remote mode the number of start attempts can be configured. Usually in marine application 3 start attempts are used Start failure output If all start attempts have expired but the engine did not start, a start fail alarm will be issued. If required this alarm can be configured to trigger any of the programmable outputs Disable pulse start In default configuration pulse start is enabled. Pushing the start button briefly in local mode will start the engine according to the start configuration (with regard to crank- and rest time). If disabled the start attempt will only proceed as long as the start button is pressed. The same applies to the stop procedure. Note that in local mode only 1 start attempt is available Stop Settings Cool down time The cool down time is the time delay between activation of the stop command and the start of the stop procedure. After receiving the stop command M2500 will immediately trip the circuit breaker but allow the engine to run for the duration of the cool down time in order to cool down the engine. The cool down time is expressed in seconds and applies only in remote mode. Shutdowns will be executed immediately. Revision: Page 8

9 Stop time The stop time defines the time the stop solenoid will be activated during an engine stop procedure. If the engine continues running after expiration of the stop time, a stop failure alarm will be issued. The stop command can be interrupted if the engine is still in cool down and stop signal is removed from the stop input (terminal 9) and a start command is given at the start input (terminal 8). However cranking will be blocked until both engine speed detection is low and the oil pressure is low Stop failure output If the stop time has expired but the engine is still running (detection of crank disconnect speed) a stop fail alarm will be issued. If required this alarm can be configured to trigger any of the programmable outputs Run/ Stop Solenoid Settings Enable cable monitoring M2500 includes the possibility of cable monitoring between the stop/ run solenoid output of M2500 (terminals 66/ 67) and the stop or run solenoid Run/Stop relay as The Run/ Stop output of M2500 (terminals 66/ 67) can be configured to operate with a run solenoid (energized to run) or a stop solenoid (energized to stop). Usually the application defines which should be used: - Auxiliary generators use run solenoids. - Emergency generators use stop solenoids. Revision: Page 9

10 2.1.4 Pre-lubrication Enable lubrication When enabled, this function will lubricate the engine when the engine is stopped Mode Continuous and periodic mode are available. Continuous mode means that the will be active continuously with engine not running (between expiration of stop procedure until next cranking. Periodic means that the pre-lubrication works in intervals with engine not running. Interval time and lubrication time can be configured Interval Interval between each lubrication period. It is expressed in minutes Duration Duration of each lubrication period. It is expressed in minutes Starter engagement protection The starter engagement protection is used in order to prevent the starter from engaging to the flywheel in case the speed signal is lost and a start command is being given. Thus it protects the starter from damage. The function will check for oil pressure before each start attempt. In case oil pressure is present the start attempt will be suppressed and an alarm will be issued. Naturally the starter engagement protection cannot run together with the pre lubrication function, as pre lubrication would then prevent the engine from starting, as oil pressure would be present in spite of a not running engine. Revision: Page 10

11 Enabled This command enables or disables the starter engagement protection Oil pressure source The starter engagement protection needs to read the oil pressure in order to decide whether the engine is running or not. This command assigns the oil pressure sensor to the starter engagement protection function. The source can be any of the digital inputs, any of the analogue inputs or the J1939 bus Service indication Note: When the operator attempts to access the service indication page, he is prompted for the configuration pin code Service interval Adjustment of the running hours between each service interval. 2.2 Analogue input configuration Configuration of the analogue sensor inputs.. All analogue inputs use 4-20mA signals. The analogue inputs screen gives an overview over all analogue inputs: Revision: Page 11

12 Specific inputs can be selected by the up and down cursor keys. The configuration of the specific input can be entered by the curser right key: Text Sensor name editor.. Choose Text and press cursor right: The name of the sensor can be chosen via the up/down cursor (each letter individually). Move cursor to Save & Exit and press ENTER in order to accept the change. Press ESC in order to discard the change. Note: Text editing The following applies for the alarm text editor as well as any other text being edited. The following characters are available in the editor Please note they are presented in 5 groups: 1) a-z Lower case letters 2) A_Z Upper case letters 3) 0-9 Numbers 4) Special characters including, % 5) Empty character/ space In order to facilitate easier text editing, long pressing the up button will fast forward to the first character in the next character group. E.g., if the current character in the editor is k, then long pressing the up button, will change the character to A since that is the first character in the next character group. Similarly, long pressing the down button will change the character to the last character of the previous character group. Revision: Page 12

13 2.2.2 Unit The unit of the measurement can be chosen (as text) with help of the up/down cursor keys Cable monitoring enabled Cable monitoring can be enabled or disabled for the specific input. If enabled a cable fail alarm will be issued in case the measurement signal on the input drops below 4mA Scale, min. Adjustment of minimum measurement at input signal of 4mA Scale, max. Maximum measurement at input signal of 20mA Show decimal Indication of measurement with none or one decimal (e.g. 1 bar or 1,0 bar). 2.3 Digital Input configuration Configuration of the digital sensor inputs. All digital inputs use voltage free contacts. The digital inputs screen gives an overview over all digital inputs: Specific inputs can be selected by the up and down cursor keys. The configuration of the specific input can be entered by the curser right key: Revision: Page 13

14 2.3.1 Text Sensor name editor. Choose Text and press cursor right: The name of the sensor can be chosen via the up/down cursor (each letter individually). Move cursor to Save & Exit and press ENTER in order to accept the change. Press ESC in order to discard the change Cable monitoring Cable monitoring can be enabled or disabled for the specific input. For cable monitoring of digital inputs resistors have to be mounted close to the sensor (see installation manual). 2.4 J1939 input configuration The measurements can be taken from the J1939 bus. For this the J1939 bus must be enabled. Note: When the J1939 communication is enabled, the M2500 expects communication on the CAN-J1939 interface More specifically it expects the J1939 messages carrying the expected SPN signals. If it does not detect any communication (Not connected to bus, or remote ECU not active), a communication error alarm will be activated. It should be noted that to suppress the communications error alarm, all expected SPN signals must be present on the bus. Revision: Page 14

15 2.5 Alarm configuration The alarms screen shows a list of all programmable alarms: Each line, presents a summary of the alarm; First column indicates if the alarm gives Shutdown signal or not (alarm or shutdown). A shutdown is indicated by an exclamation mark. The checkbox in the Second column indicates if the alarm is enabled or not. The third column shows the text label assigned to the alarm. The status line at the bottom shows a summary of the trigger (Input and setpoint) for the selected alarm. Note: Navigating lists -Long-pressing the up and down buttons, takes you to the top/bottom of the list. - Pressing the up button, whilst the top most item is selected, takes you to the bottom of the list. - Pressing the down button, whilst the bottom most item is selected, takes you to the top of the list. To edit an alarm, move the cursor to the alarm and press the enter button. The alarm editor is presented: Revision: Page 15

16 2.5.1 Text Alarm text editor. Place the cursor over the Text entry and press the enter button: The name of the sensor can be chosen via the up/down cursor (each letter individually). Move cursor to Save & Exit and press ENTER in order to accept the change. Press ESC in order to discard the change Enabled Alarms can be enabled and disabled Alarm type Here the type of alarm is selected: Alarms are indicated on the Common output (terminal 46) and the Alarm LED. Alarms will not give shut down. The engine will continue running. Shutdowns are indicated on the Shutdown output and the corresponding LED, while initiating the shutdown procedure. Shutdown with override: This type of alarm is handled differently depending on the Override input (Terminal 10). - Override not activated: Treated as a Shutdown - Override activated: Treated as a normal alarm (i.e. engine will not be stopped) Auto reset Each alarm can be configured for manual or auto rest. In auto reset, the alarm disappears automatically when the alarm condition disappears. If auto reset is not selected, the alarm must be manually reset before it disappears from the LED and current alarm list. Alarms set to manual reset will block the engine from starting Monitoring Alarms can be configured to continuous monitoring or monitoring with engine running only. Continuous monitoring means that the alarm condition is monitored regardless if the engine is running or not. Revision: Page 16

17 Running only alarms are monitored after M2500 has detected that the engine is running (crank disconnect condition) and expiration of the monitoring delay. In default configuration this is 8 s after detection of the crank disconnect signal. Note: Typical alarms and shutdowns for continuous monitoring are over speed, emergency stop and high water temperature. Typical alarm and shutdown for running only is oil pressure Delay Each alarm can be configured with an individual alarm delay. This delay is expressed in seconds. Only if the alarm condition remains active for the entire alarm delay the alarm is issued Input This line shows a summary of the input criteria for the alarm being edited. To edit the input criteria, press the ENTER button to bring up the alarm input editor Input source Selection of the input source of the input alarm signal. Options are: Analogue RPM (Pick up) Digital J Input channel The specific channel is selected. The channel may correspond to a physical input or a bus-signal (J1939). The number of channels depends on the input source: Analogue: 1-8 (SENSOR 1 - SENSOR 8 inputs) RPM: 1 (Pick-up input) Digital: 1-9 (INPUT 1 INPUT 9 inputs) J1939: SPN 100, SPN 110, SPN 190 Revision: Page 17

18 J1939 channels For J1939 inputs, the channel indicates the J1939 signal / SPN number: Oil Pressure SPN 100 Coolant Temperature SPN 110 Engine Speed SPN Set point Configuration of the actual set point differs depending on the input source Analogue, RPM and J1939 For alarms monitoring an analogue type value (including RPM and J1939) the input trigger level is expressed in terms of a trigger level and an >= or <= operator, as shown below: The range which the trigger level can be set, depends on the selected input source and channel. The valid range is indicated in the brackets immediately under the set point value. Note: When the input source is analogue, the valid range for the trigger level depends on the configuration of the targeted analogue input channel. Revision: Page 18

19 Digital Input The digital input works with reference to COM. It can be configured to trigger an alarm in open or closed position. 2.6 Output Functions Some special output functions can be configured on the Output Functions tab Siren Reset The Siren Reset button can be configured to activate any of the programmable outputs. Purpose of this function is to reset an external alarm system with the siren reset button on M2500. Revision: Page 19

20 2.6.2 Alarm Reset The Alarm Reset button can be configured to activate any of the programmable outputs. Purpose of this function is to reset an external alarm system with the alarm reset button on M Dashboard configuration Device name Configuration of the device name. Revision: Page 20

21 2.7.2 Oil Inp. Src (Engine oil pressure gauge) Selection of the Engine Oil pressure gauge input. Options are: Analogue SENSOR 1 input J1939, SPN 100 Note: When input source is set to J1939, the J1939 communication must be enabled Water inp. Src (Engine coolant water temperature gauge) Selection of the Engine Coolant water temperature gauge input. Options are: Analogue SENSOR 2 J1939, SPN 110 Note: When input source is set to J1939, the J1939 communication must be enabled 2.8 Modbus configuration The RS485 communication interface can be configured with regard to MODBUS slave address, baud rate and parity. Note: MODBUS slave address The MODBUS slave address must be unique on the MODBUS network Note: RS-485 network termination Make sure the underlying RS-485 network is properly terminated. If the M2500 is the last node on your network, the switch DIP1 on the back of the device can be used to enable an internal termination resistor. Revision: Page 21

22 2.9 Display and LED configuration This section is for dimming of the LED and the Backlit display. The LED intensity and LCD backlight intensity changes as you alter the value in the dialogue. LED test can be performed by choosing LED test in the dialogue or long pressing gauges button Time and date Adjustment of date and time to be shown by the controller and used by the Log Revision: Page 22

23 2.11 Password configuration In this menu the service and configuration password can be set. The service password must be entered in order to get access to these settings. After the password has been entered the settings are accessible: Note: The passwords are NOT reset when the configuration parameters are reset or by upgrading the firmware. Make sure to keep safe copies of your passwords, if changed! Revision: Page 23

24 2.12 Firmware update from SD card The firmware upgrade runs automatically once initiated. It is not necessary to export the configuration or log files before the firmware upgrade. The M2500 will automatically save backups of both configuration and log and will restore the configuration automatically as part of the upgrade procedure. The M2500 firmware consists of two files: M2500.bin M2500.md5 In order to upgrade the firmware, these two files must be present in the root directory of the SD card: Insert the SD card containing the firmware into the SD card slot of M2500, enter the configuration mode (password required) and choose Firmware update from SD card. Following screen will appear: Revision: Page 24

25 After pressing ENTER the firmware upgrade will run automatically through following steps: Step Description Validating firmware Backing up firmware The M2500 checks if the new firmware is valid (e.g. if it has access to both M2500 firmware files) The M2500 creates a backup of the firmware that is currently installed on the M2500 in the backup folder on the SD card Backing up configuration The M2500 creates a back up file of the configuration currently installed on the M2500 Backing up log Copying firmware Programming flash Rebooting Restoring configuration The M2500 creates a back up file of the log currently installed on the M2500 The M2500 copies the new firmware from the SD card to the internal memory Firmware upgrade running Restart of M2500 (the screen will briefly become black) The configuration is restored to the condition before the upgrade After the firmware upgrade has finished the unit will show following screen: Press Enter or ESC to return to the configuration menu. Note: SD card up to 4GB can be used with M2500. Bigger cards are incompatible. Revision: Page 25

26 2.13 Save configuration to SD card This menu is used in order to save a copy of the configuration of the M2500 to the SD card. - Enter the configuration mode by pressing - Type pin code and press - Choose Save configuration to SD card by pressing - - Press - The configuration is now copied to the SD card Note: This process will overwrite any existing configurations stored on the SD card. Note: SD cards up to 4GB can be used with M2500. Bigger cards are incompatible. Now a copy of the configuration (config.cfg) is saved in the root directory of the SD card: Revision: Page 26

27 2.14 Load configuration from SD card This menu is used in order to install a configuration from the SD card to the M2500. Note: SD card up to 4GB can be used with M2500. Bigger cards are incompatible. In order to import a configuration (config.cfg) from the SD card to the M2500 the configuration file must be saved in the root directory of the M2500 SD card: For loading of a configuration file from the SD card insert the card into the M Enter the configuration mode by pressing - Type pin code and press - Choose Load configuration from SD card card by pressing - Press - Confirm load of configuration by choosing YES (press ) and press Now the configuration will be uploaded from the SD card and saved on the M2500. Revision: Page 27

28 2.15 Reset all settings to default values This command will reset the configuration to factory default values. While resetting, the M2500 will prompt with the following screen: After resetting the File system busy window will close About (SW Revision) This dialogue indicates the Software revision date and the serial number of the M2500: 2.17 Language configuration The display language can be switched between English and Russian. Revision: Page 28

29 3 Automatic configuration update from SD It is possible to update the configuration from the SD card in an automated fashion This is useful if you have to apply a given configuration to multiple devices. The steps are: 1. Place a configuration file in the root of the SD card and name it auto.cmd. 2. Insert the SD card into M M2500 now detects the presence of the auto.cmd file and prompts the user for the configuration pin code. If the operator enters a valid configuration pin code, M2500 proceeds to read in the configuration. Note: The auto.cmd file is not deleted after it has been parsed. This allows the operator to move the SD card on to a new device. Note: SD card up to 4GB can be used with M2500. Bigger cards are incompatible. Revision: Page 29

30 4 Configuration via PC (USB) The PC application needed to configure the M2500 is built into the M2500 firmware and is preinstalled on the internal drives of the M2500. When connected to a compatible PC via a USB cable, the internal drives of the M2500 are presented in the Windows file manager, similar to accessing a USB key or a USB hard disc. Note: HTA support The configuration and log-viewer applications are implemented using HTA technology. This is a Microsoft-only technology and is only supported by the MS Windows operating system with internet explorer 5.0 or later. Note: USB Mass Storage The USB Mass Storage technology is widely supported. The internal drives of M2500 containing the configuration and log files can be accessed by virtually any computer Even if it is not running a Microsoft operation system. 4.1 Connecting to a PC When M2500 detects a USB cable, M2500 begins a process that ensures all drives contain up-todate configuration and log data: The progress is illustrated on the user interface. When the drives are up to date, the user interface is locked, preventing the operator from making local configuration changes whilst connected to the PC: Note: Locking the user interface does not affect the functionality. The M2500 will continue running and it will be possible to start and stop engines locally or remotely. Revision: Page 30

31 M2500 stays in this mode until the USB cable is detached. When connected to a PC the M2500 implements a USB key -like feature (USB Mass storage). When the M2500 is connected to a PC, three drives will appear in your file manager. These drives behave like standard USB mass storage device and the content can be dragged and dropped to the drive. The drives SELCO Log (the log drive) and SELCO Configuration (the configuration drive) are internal memory of M2500. The log drive is a read only drive. It is not possible to erase the event log from the system. Note: Circular log When the log drive becomes full, the log-file will automatically remove the oldest log-entries to in order to make room for new events. The log will always contain the most recent events. The drive SELCO SD is the SD card M2500 effectively operates like a standard card reader. Note: The changes made through the configuration tool must be saved to the configuration drive The configuration will be saved when the USB cable is disconnected. Revision: Page 31

32 4.2 Description of the configuration tool The configuration tool is saved on the configuration drive of the M2500. The configuration tool will open in the web browser. It is not necessary to install any programming software on the PC. Double click on the config.hta file in the root of the configuration drive and the configuration tool will open in your web browser (the configuration itself is saved in the config.cfg file. The configuration parameters are organized in tabs similarly to the way the configuration menu is organized. Revision: Page 32

33 4.3 Saving of changes in the configuration Save all After changes have been made, the configuration must be saved to the config.cfg file on the configuration disc. This can be done by clicking on the Save all button on the bottom of the configuration spread sheet: The Save all button will save all changes on all spread sheets Note: After pressing the save all button, the changes will only be saved on the Configuration Drive. They will not be loaded to the internal memory of the M2500 and will not influence the operation of M2500. The changes will be saved on the M2500 when the USB cable is disconnected. When the cable is removed, M2500 reads the configuration drive to see if the configuration tool left a config.cmd file i.e. if the operator saved a configuration If so, the user is presented with a pin code prompt. If the user rejects the dialogue with the esc button, the configuration is rejected (Deleted). If a valid password is entered, the configuration is parsed and M2500 is updated accordingly. Revision: Page 33

34 4.3.2 Reset Page The reset page button will reset all settings on the current page to the factory default settings: Revert Page Revert page will re-establish the original configuration for all parameters on the selected screen. Revision: Page 34

35 4.4 Engine Controller Tab The first tab includes the engine controller settings such as rpm settings, start and stop parameters, and the configuration of the starter engagement protection as described in chapter Revision: Page 35

36 4.5 Digital Inputs Tab This tab includes the configuration of the digital inputs. Click on Edit in order to start configuration of the digital input. Revert resets the input to the last saved setting. Click Reset in order to reset the input to the factory default configuration. Copy will copy all settings of the specific input. They can then be pasted to any of the other digital inputs. Paste will paste the copied settings to the specific digital input ( Paste will only appear after settings have been copied ) Click on Edit in order to start configuration of the digital input: On this screen the name of the digital input can be configured and the cable monitoring function for this particular input can be enabled or disabled. Revision: Page 36

37 4.6 Analogue Inputs Tab This tab includes the configuration of the analogue inputs. Click on Edit in order to start configuration of the analogue input: Show decimal point If activated, following scale means 1 to 10 bar. If deactivated it would mean 10 to 100 bar. Revision: Page 37

38 4.7 Alarms Tab This tab includes the configuration of the alarms. Click on Edit in order to configure an alarm: Revision: Page 38

39 4.8 Output Functions Tab Special output functions can be configured on the output functions tab:... Revision: Page 39

40 4.9 General Parameters Tab The LED and display back light intensity (dimming), the dashboard and the display language can be configured on the General Parameters Tab Communication Tab This tab includes the configuration of the J1939 and RS485 communication. Revision: Page 40

41 4.11 Service Indication Tab This tab includes the configuration of the Service indication. Revision: Page 41

M2500 Engine Controller Operator Manual

M2500 Engine Controller Operator Manual M2500 Engine Controller Operator Manual Revision: 08-03-2011 Page 1 Contents 1 Preface... 4 2 Front View of M2500... 5 3 Front panel LEDs... 6 3.1 Engine running LED... 6 3.2 Remote LED... 6 3.3 Local

More information

Genset control and protection with safety system

Genset control and protection with safety system APPLICATION NOTES Generator Protection Unit, GPU-3 APPLICATION NOTES Genset control and protection with safety system Application description Functional description Wiring I/O lists Basic setup Flowcharts

More information

Cascade Configuration Tool

Cascade Configuration Tool Cascade Configuration Tool Version 1.0.10 Installation and Operations Manual 00-02-0724 01-25-11 Section 40 In order to consistently bring you the highest quality, full featured products, we reserve the

More information

Option M2 Configurable engine control cards Multi-line 2 version B SW version 2.4X.X

Option M2 Configurable engine control cards Multi-line 2 version B SW version 2.4X.X Description of options Option M2 Configurable engine control cards Multi-line 2 version 2 4189340482B SW version 2.4X.X Description of options Functional description DEIF A/S Display units Additional functions

More information

Manual# Installation Manual SDU 410. Safety Shutdown Unit

Manual# Installation Manual SDU 410. Safety Shutdown Unit Manual# 1100641 Installation Manual SDU 410 Safety Shutdown Unit Installation Manual for SDU 410 ~~~ Safety Shutdown Unit Revision 1.0 Revised August 31, 2017 Revision history: Rev. Date Description 1.0

More information

Quick Installation Guide

Quick Installation Guide Manual# 1100274 Quick Installation Guide SDU 410 Safety Unit Quick Installation Guide for SDU 410 Safety Unit ~~~ Revision 1.1 Revised November 10, 2016 Revision history: Rev. Date Description 1.0 04.2012

More information

BEP 600-ACSM AC SYSTEMS MONITOR. Installation and Operating Instructions. Page 1

BEP 600-ACSM AC SYSTEMS MONITOR. Installation and Operating Instructions. Page 1 BEP 600-ACSM AC SYSTEMS MONITOR Installation and Operating Instructions Page 1 This page has been deliberately left blank Page 2 Table of Contents 1. BASICS 4 WARNING AND CAUTION 4 WARNING 4 CAUTION 4

More information

HMC9000A DIESEL ENGINE CONTROLLER (With J1939 Interface) USER MANUAL SMARTGEN (ZHENGZHOU) TECHNOLOGY CO.,LTD.

HMC9000A DIESEL ENGINE CONTROLLER (With J1939 Interface) USER MANUAL SMARTGEN (ZHENGZHOU) TECHNOLOGY CO.,LTD. HMC9000A DIESEL ENGINE CONTROLLER (With J1939 Interface) USER MANUAL SMARTGEN (ZHENGZHOU) TECHNOLOGY CO.,LTD. Chinese trademark English trademark SmartGen make your generator smart SmartGen Technology

More information

Rudolf R3 User s Manual

Rudolf R3 User s Manual Rudolf R3 User s Manual DCU 305 R3 Control Unit configuration tool Contents 1 Introduction... 4 1.1 Important information 4 1.2 System requirements 4 1.3 Installation of Rudolf R3 5 2 Menu Overview...

More information

DEEP SEA ELECTRONICS PLC

DEEP SEA ELECTRONICS PLC COMPLEX SOLUTIONS MADE SIMPLE. DEEP SEA ELECTRONICS PLC DSE5320 AUTO MAINS FAILURE MODULE OPERATING MANUAL http://bestgenerator.spb.ru/?page_id=6765 Deep Sea Electronics Plc Highfield House Hunmanby North

More information

PowerView. Model PV-101-A, V2.3 User s Guide Section 78

PowerView. Model PV-101-A, V2.3 User s Guide Section 78 PowerView Model PV-101-A, V2.3 User s Guide 10-18-11 00-02-0795 Section 78 In order to consistently bring you the highest quality, full featured products, we reserve the right to change our specifications

More information

5450 NW 33rd Ave, Suite 104 Fort Lauderdale, FL Fruitland Ave Los Angeles, CA UM Channel Monitor.

5450 NW 33rd Ave, Suite 104 Fort Lauderdale, FL Fruitland Ave Los Angeles, CA UM Channel Monitor. 5450 NW 33rd Ave, Suite 104 Fort Lauderdale, FL 33309 3211 Fruitland Ave Los Angeles, CA 90058 UM-600 6-Channel Monitor Version 2 Installation and Operation Manual Rev. G P/N145F-12990 PCO 00007462 (c)

More information

lindab we simplify construction LindabUltraLink Configuration Tool Manual

lindab we simplify construction LindabUltraLink Configuration Tool Manual lindab we simplify construction LindabUltraLink Configuration Tool Manual Contents 1. General Information...2 2. Installation...2 3. Connecting UltraLink to personal computer...2 4. Starting the UltraLink

More information

Installation and Configuration Manual

Installation and Configuration Manual Manual# 1100288 Installation and Configuration Manual 200 Series DCU 210/208 Engine Panel RP 210 Remote Panel DMU 206 - CANbus Reader Installation and Configuration Manual for the Marine Pro 200 Series

More information

Genset Controller Unit Model EMS - GC10. Installation Manual Section

Genset Controller Unit Model EMS - GC10. Installation Manual Section Genset Controller Unit Model EMS - GC10 Installation Manual 00-02-0794 Section 75 2013-01-28 In order to consistently bring you the highest quality, full featured products, we reserve the right to change

More information

Manual# Configuration Manual. 400E Series. DCU 410E Engine Control Unit RP 410E Remote Panel

Manual# Configuration Manual. 400E Series. DCU 410E Engine Control Unit RP 410E Remote Panel Manual# 1006423 Configuration Manual 400E Series DCU 410E Engine Control Unit RP 410E Remote Panel RP 410E DCU 410E Configuration Manual for Marine Pro 400E Series ~~~ DCU 410E Diesel Engine Control Unit

More information

6-Channel Monitor. Installation and Operation Manual

6-Channel Monitor. Installation and Operation Manual 3211 Fruitland Ave Los Angeles, CA 90058 Catalyst Monitor 6-Channel Monitor Version 2 Installation and Operation Manual Rev. H P/N145F-12964 PCO - 00009743 (c) Copyright 2015, Barksdale, Inc. All Rights

More information

How to Update NN3D to v2.07 (Combo Update) MFDBB

How to Update NN3D to v2.07 (Combo Update) MFDBB How to Update NN3D to v2.07 (Combo Update) MFDBB 1. NN3D v2.07 Update Introduction MFDBB The combo update for the MFDBB requires a USB Jump Drive (USB flash memory stick). Additionally, a USB KEYBOARD

More information

DEEP SEA ELECTRONICS PLC

DEEP SEA ELECTRONICS PLC COMPLEX SOLUTIONS MADE SIMPLE. DEEP SEA ELECTRONICS PLC DSE5520 AUTOMATIC MAINS FAILURE CONTROL MODULE OPERATING MANUAL Deep Sea Electronics Plc Highfield House Hunmanby North Yorkshire YO14 0PH ENGLAND

More information

APC715 Pump Unit Controller USER MANUAL. Smartgen Technology

APC715 Pump Unit Controller USER MANUAL. Smartgen Technology USER MANUAL Smartgen Technology Chinese trademark English trademark Smartgen make your generator smart Smartgen Technology Co., Ltd. No. 28 Jinsuo Road Zhengzhou Henan Province P. R. China Tel: +86-371-67988888/67981888

More information

OPERATOR'S MANUAL Generator Paralleling Controller, GPC-3 - Generator Protection Unit, GPU-3/GPU-3 Hydro - Paralleling and Protection Unit, PPU-3

OPERATOR'S MANUAL Generator Paralleling Controller, GPC-3 - Generator Protection Unit, GPU-3/GPU-3 Hydro - Paralleling and Protection Unit, PPU-3 OPERATOR'S MANUAL Generator Paralleling Controller, GPC-3 - Generator Protection Unit, GPU-3/GPU-3 Hydro - Paralleling and Protection Unit, PPU-3 Display and push-button functions Alarm handling Log list

More information

4-1. This chapter explains HMI settings.

4-1. This chapter explains HMI settings. 4-1 4. Hardware Settings This chapter explains HMI settings. 4.1. Overview... 4-2 4.2. I/O Ports... 4-2 4.3. LED Indicators... 4-2 4.4. System Reset... 4-3 4.5. System Toolbar... 4-4 4.6. System Setting

More information

InteliDrive Nano. Reference Guide. Engine Controller. InteliDrive Nano. Compact Controller for Industrial Engines. SW version 1.

InteliDrive Nano. Reference Guide. Engine Controller. InteliDrive Nano. Compact Controller for Industrial Engines. SW version 1. InteliDrive Nano InteliDrive Nano Engine Controller Compact Controller for Industrial Engines SW version 1.3, October 2012 Reference Guide Copyright 2012 ComAp s.r.o. ComAp, spol. s r.o. Kundratka 17,

More information

DCU 305 R2. Communication Manual. Auto-Maskin AS. Page 1 of 25

DCU 305 R2. Communication Manual. Auto-Maskin AS. Page 1 of 25 DCU 305 R2 Communication Manual Auto-Maskin AS Page 1 of 25 Content DOCUMENT INFORMATION... 3 COMMUNICATION... 5 IN GENERAL... 5 THE PROTOCOLS... 5 ID-number... 6 Signal Converters when and why do I need

More information

PowerView. Model PV-101 User s Guide. Rev Catalog Section 78

PowerView. Model PV-101 User s Guide. Rev Catalog Section 78 PowerView Model PV-101 User s Guide Rev 09-10-08 00-02-0605 Catalog Section 78 In order to consistently bring you the highest quality, full featured products, we reserve the right to change our specifications

More information

ADVANCED OPERATOR PANEL (AOP)

ADVANCED OPERATOR PANEL (AOP) ADVANCED OPERATOR PANEL (AOP) Operating Instructions Issue 04/02 English Contents 1 Warnings and Notes 3 1.1 Special Key Functions 4 2 Applications Examples 4 2.1 Single drive control using the AOP 4 2.2

More information

DATA SHEET Compact Genset Controller, CGC 200

DATA SHEET Compact Genset Controller, CGC 200 DATA SHEET Compact Genset Controller, CGC 200 Auto start and parameter monitoring Warnings and shutdown protections Includes 5 digital inputs, 5 relay outputs Configurable for other applications Licence-free

More information

WARNING. TTDJ Series Fully-Configurable Fault Annunciator Installation and Operations Manual

WARNING. TTDJ Series Fully-Configurable Fault Annunciator Installation and Operations Manual TTDJ Series Fully-Configurable Fault Annunciator Installation and Operations Manual TTDJ-99062N Revised 04-04 Section 50 (00-02-0412) Please read the following information before installing. This installation

More information

Manual# Installation Manual. 400E Series. DCU 410E Engine Control Unit RP 410E Remote Panel

Manual# Installation Manual. 400E Series. DCU 410E Engine Control Unit RP 410E Remote Panel Manual# 1100346 Installation Manual 400E Series DCU 410E Engine Control Unit RP 410E Remote Panel RP 410E DCU 410E Installation Manual for Marine Pro 400E Series ~~~ DCU 410E Engine Control Unit RP 410E

More information

PROGRAMMING INSTRUCTIONS

PROGRAMMING INSTRUCTIONS HOERBIGER Engine Solutions PROGRAMMING INSTRUCTIONS CPU-XL VARISPARK TERMINAL PROGRAM WARNING: WARNING: DEVIATION DEVIATION FROM THESE FROM INSTRUCTIONS THESE INSTRUCTIONS MAY LEAD MAY LEAD TO IMPROPER

More information

4-1. This chapter explains HMI settings.

4-1. This chapter explains HMI settings. 4-1 4. Hardware Settings This chapter explains HMI settings. 4.1. Overview... 4-2 4.2. I/O Ports... 4-2 4.3. LED Indicators... 4-2 4.4. System Reset... 4-3 4.5. System Toolbar... 4-4 4.6. EasySystemSetting...

More information

GSC400 PC INTERFACE SOFTWARE MANUAL. Installation and User Manual for the GSC400 PC Software Interface

GSC400 PC INTERFACE SOFTWARE MANUAL. Installation and User Manual for the GSC400 PC Software Interface 4016 Quartz Drive Santa Rosa, CA 95405 Phone: 707 539-9003 Fax: 707 539-5212 Email: sales@generatorjoe.net Web www.generatorjoe.net GSC400 PC INTERFACE SOFTWARE MANUAL Installation and User Manual for

More information

GC2000 Generator Controller Power Management and Protection

GC2000 Generator Controller Power Management and Protection GC2000 Generator Controller Power Management and Protection Control. Monitor. Protect. A powerful generator controller and power management system for marine and offshore applications SELCO s GC2000 provides

More information

Comprehensive Modular Genset Controller

Comprehensive Modular Genset Controller InteliGen Comprehensive Modular Genset Controller Brief Description InteliGen is a comprehensive AMF-controller for single and multiple generating sets operating in standby or parallel modes. A modular

More information

Service Bulletin SB685. Date: 8/18/2017 TriPac EVOLUTION Communications Update Bulletin Location: TSA Info Central\Service Bulletins

Service Bulletin SB685. Date: 8/18/2017 TriPac EVOLUTION Communications Update Bulletin Location: TSA Info Central\Service Bulletins Service Bulletin SB685 Date: 8/18/2017 Subject: TriPac EVOLUTION Communications Update Bulletin Location: TSA Info Central\Service Bulletins Units: All TriPac EVOLUTION Summary: This bulletin updates and

More information

Iso DIN. User Manual. 1 channel Earth Fault Monitoring

Iso DIN. User Manual. 1 channel Earth Fault Monitoring Page 1 of 5 2017 03 20 User Manual Iso DIN Iso DIN User Manual 1 channel Earth Fault Monitoring Megacon AB Ranhammarsvägen 20 S 168 67 Bromma Sweden Tel: 08 402 42 50 sales@megacon.se www.megacon.se eee

More information

FT2 View Instruction Manual

FT2 View Instruction Manual 399 Reservation Road, Marina, California U.S.A. Ph: (831) 384-4300 Fax: (831) 337-5786 www.foxthermalinstruments.com 2006 Fox Thermal Instruments, Inc. 07/19/13 Introduction: The FT2 View application software

More information

Quantum HD Release Notes

Quantum HD Release Notes Quantum HD Release Notes OS Version 10.17 Released 7-14-2014 To upgrade to OS version 10.17 directly the current OS version must be 10.13 through 10.16. To check the current OS version on the Quantum HD

More information

User s Manual. Version 1.0 PAGE 1 OF 38

User s Manual. Version 1.0 PAGE 1 OF 38 User s Manual Version 1.0 PAGE 1 OF 38 1 Table of Contents 2 Overview... 6 3 Launching Project Editor... 8 4 Creating a New Project... 9 4.1 Initial Vehicle validation... 9 4.2 Project Properties Screen...

More information

PF2100 MODBUS LOGGER CARD SYSTEM SPECIFICATION. v1.0 DRAFT Revised Dec 4, 2014 Last Revised by Alex Messner

PF2100 MODBUS LOGGER CARD SYSTEM SPECIFICATION. v1.0 DRAFT Revised Dec 4, 2014 Last Revised by Alex Messner PF2100 MODBUS LOGGER CARD SYSTEM SPECIFICATION Revised Last Revised by Alex Messner This page was intentionally left blank. Table of Contents 1 Overview... 2 2 User Interface... 3 2.1 LEDs... 3 2.2 Buttons...

More information

PowerWizard 1.1, 1.1+ & & 2.1 Generating Set Control Technical Manual

PowerWizard 1.1, 1.1+ & & 2.1 Generating Set Control Technical Manual PowerWizard 1.1, 1.1+ & & 2.1 Generating Set Control Technical Manual Contents Important Safety Information 5 1. General Information 6 1.1 Introduction... 6 1.2 Applications... 6 1.3 PowerWizard Variations...

More information

DSEULTRA DSE3110 Series Control Module

DSEULTRA DSE3110 Series Control Module DSEULTRA DSE3110 Series Control Module 057-086 Author : Anthony Manton DSE Model 3000 Series Control and Instrumentation System Operators Manual Deep Sea Electronics Plc Highfield House Hunmanby North

More information

User Manual PDUTracker

User Manual PDUTracker User Manual PDUTracker Management Software for PDU Table of Contents 1. Overview... 1 1.1. Introduction... 1 1.2. Features... 1 2. Install and Uninstall... 1 2.1. System Requirement... 1 2.2. Software

More information

Show Designer 1. Software Revision 3.11

Show Designer 1. Software Revision 3.11 Show Designer 1 Software Revision 3.11 OVERVIEW The Show Designer 1 is a lighting controller based on the successful and simple to use Show Designer. The Show Designer 1 adds to the existing features of

More information

NORDSON CORPORATION AMHERST, OHIO USA

NORDSON CORPORATION AMHERST, OHIO USA CanWorks Operator Interface Tracking PLUS for CanWorks Systems with SM-2 Spray Monitors User Guide Part 1018132A NORDSON CORPORATION AMHERST, OHIO USA 2002 Nordson Corporation. All rights reserved. CanWorks,

More information

ProTech-SX Simplex System. Product Manual 26546V2 (Revision A) Original Instructions , Volume 2 Programming and Configuration

ProTech-SX Simplex System. Product Manual 26546V2 (Revision A) Original Instructions , Volume 2 Programming and Configuration Product Manual 26546V2 (Revision A) Original Instructions ProTech-SX Simplex System 8237-1242, -1243 Manual 26546 consists of 2 volumes (26546V1 & 26546V2). Volume 2 Programming and Configuration General

More information

iologik R1200 Series User s Manual

iologik R1200 Series User s Manual User s Manual Edition 3.2, November 2017 www.moxa.com/product 2017 Moxa Inc. All rights reserved. User s Manual The software described in this manual is furnished under a license agreement and may be used

More information

Quick Installation Guide

Quick Installation Guide Manual# 1100406 SDU 404 Safety Unit for SDU 404 Safety Unit ~~~ Revision 1.1 Revised June 10, 2015 Revision history: Rev. Date Description 1.0 20.8.2014 Initial Revision 1.1 10.6.2015 Updates after reviews.

More information

12.3 Pro Dash Quick Start Guide

12.3 Pro Dash Quick Start Guide 12.3 Pro Dash Quick Start Guide 553-111 CONTENTS: Package Contents... 3 Mounting... 3 Connections... 4 Main Connector... 4 CAN Extension Harness... 6 USB... 7 GPS Antenna... 7 Cleaning... 7 Touchscreen

More information

IS35 Color Display. User Manual ENGLISH. simrad-yachting.com

IS35 Color Display. User Manual ENGLISH. simrad-yachting.com IS35 Color Display User Manual ENGLISH simrad-yachting.com Preface Navico is continuously improving this product, therefore we retain the right to make changes to the product at any time which may not

More information

Compact Genset Controller, CGC 200 Mounting Terminals and wiring Commissioning, using the Utility Software and/or the front panel

Compact Genset Controller, CGC 200 Mounting Terminals and wiring Commissioning, using the Utility Software and/or the front panel INSTALLATION AND COMMISSIONING INSTRUCTIONS Compact Genset Controller, CGC 200 Mounting Terminals and wiring, using the Utility Software and/or the front panel DEIF A/S Frisenborgvej 33 DK-7800 Skive Tel.:

More information

MOD-RI Room Interface Modules with Modbus

MOD-RI Room Interface Modules with Modbus Product sheet MOD3.00 Type MOD-RI MOD-RI Room Interface Modules with Modbus The MOD-RI are room interface modules designed to provide room control interface for the building management systems. The MOD-RI

More information

Release Notes: NetAXS Firmware Release January 14, NetAXS-4 Firmware R Release Notes. NetAXS-4. Revision 06

Release Notes: NetAXS Firmware Release January 14, NetAXS-4 Firmware R Release Notes. NetAXS-4. Revision 06 NetAXS-4 Firmware R03.04.18 Release Notes NetAXS-4 Revision 06 Table of Contents Notices and Trademarks... 3 Terms, Acronyms, Abbreviations, and Symbols... 3 I. RELEASE CONTENTS... 3 Product Name and Model...

More information

PowerView. Model PV-101-C User s Guide Version Catalog Section 78

PowerView. Model PV-101-C User s Guide Version Catalog Section 78 PowerView Model PV-101-C User s Guide Version 3.1 10-11-10 00-02-0718 Catalog Section 78 Table of Contents Introduction... 1 Engine and Transmission Parameters 2 Faceplate Features 3 Navigation and Keypad

More information

Technical documentation NLS-3000 NAVIGATION LIGHT CONTROL PANEL

Technical documentation NLS-3000 NAVIGATION LIGHT CONTROL PANEL Technical documentation LIGHT CONTROL PANEL For use on seagoing vessels Change status Version Date Author Checked Remark 0.1 07.08.2008 STO HN 1. Edition Page 1 of 26 Table of contents 1. Application and

More information

GSC300 CONFIGURATOR SOFTWARE INTERFACE. Installation and User Manual for the GSC300 Configurator PC Software Interface

GSC300 CONFIGURATOR SOFTWARE INTERFACE. Installation and User Manual for the GSC300 Configurator PC Software Interface GSC300 CONFIGURATOR SOFTWARE INTERFACE Installation and User Manual for the GSC300 Configurator PC Software Interface File: ConfiguratorRev1.5.2.doc Feb.21, 2006 2 READ MANUAL BEFORE INSTALLING UNIT END-USER

More information

DEEP SEA ELECTRONICS PLC

DEEP SEA ELECTRONICS PLC DEEP SEA ELECTRONICS PLC DSE60xx Series Control Module Document Number 057-112 Author : Anthony Manton http://bestgenerator.spb.ru/?page_id=6765 DSE Model 60xx Series Control and Instrumentation System

More information

LED Commander 16/2 DMX controller. user manual

LED Commander 16/2 DMX controller. user manual LED Commander 16/2 DMX controller user manual Musikhaus Thomann Thomann GmbH Hans-Thomann-Strasse 1 96138 Burgebrach Germany Telephone: +49 (0) 9546 9223-0 E-mail: info@thomann.de Internet: www.thomann.de

More information

CENTURION Configurable Controller. Installation and Operations Manual Section 50

CENTURION Configurable Controller. Installation and Operations Manual Section 50 CENTURION Configurable Controller Installation and Operations Manual 00-02-0590 10-10-06 Section 50 In order to consistently bring you the highest quality, full featured products, we reserve the right

More information

iologik R1200 Series User s Manual

iologik R1200 Series User s Manual User s Manual First Edition, April 2013 www.moxa.com/product 2013 Moxa Inc. All rights reserved. User s Manual The software described in this manual is furnished under a license agreement and may be used

More information

Graphical User Interface V1.0.3

Graphical User Interface V1.0.3 Graphical User Interface V1.0.3 Application User Guide 2015 MCI Solutions. All rights reserved. 240815-01 www.mcisolutions.ca Page ii Getting Started Table Of Contents Introduction.................................................

More information

InteliNano NT Plus Modular Gen-set Controller with Current Measurement

InteliNano NT Plus Modular Gen-set Controller with Current Measurement InteliNano NT InteliNano NT Plus Modular Gen-set Controller with Current Measurement Compact Controller for Stand-by Operating Gen-sets SW version 1.4, March 2013 Reference Guide TABLE OF CONTENTS 1 Document

More information

Synchronizing Systems

Synchronizing Systems Synchronizing Systems AGN Technology brings alternative solution to energy projects by using synchronizing systems. With combining more than one generator for your high KVA needs, this system provides

More information

Startup Guide. NetAXS-123. Version 5.2

Startup Guide. NetAXS-123. Version 5.2 NetAXS-123 Startup Guide Version 5.2 This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2)

More information

Comprehensive Modular Genset Controller

Comprehensive Modular Genset Controller Inteligen Learn More Comprehensive Modular Genset Controller Brief Description The Inteligen is a comprehensive controller for single and multiple generating sets operating in standby or parallel to the

More information

Rudolf R2 User s Manual

Rudolf R2 User s Manual Rudolf R2 User s Manual DCU 305 R2 Control Unit configuration tool Contents 1 Introduction... 4 1.1 Important information 4 1.2 System requirements 4 1.2.1 Minimum PC requirements 5 1.3 Installation of

More information

Manual# Installation Manual SDU 404. Shutdown Unit

Manual# Installation Manual SDU 404. Shutdown Unit Manual# 1100413 Installation Manual SDU 404 Shutdown Unit Installation Manual for SDU 404 ~~~ Safety/Shutdown Unit Revision 1.1 Revised March 21, 2016 Revision history: Rev. Date Description 1.0 19.02.16

More information

IPM650 Intelligent Panel-Mount Display

IPM650 Intelligent Panel-Mount Display Quick Start Guide IPM650 Intelligent Panel-Mount Display Sensor Solutions Source Load Torque Pressure Multi Component Calibration Instruments Software www.futek.com Getting Help TECHNICAL SUPPORT For more

More information

PduSetup User Manual. Professional Electronics for Automotive and Motorsport

PduSetup User Manual. Professional Electronics for Automotive and Motorsport Professional Electronics for Automotive and Motorsport 6 Repton Close Basildon Essex SS13 1LE United Kingdom +44 (0) 1268 904124 info@liferacing.com www.liferacing.com PduSetup User Manual Document revision:

More information

HGM9580 Bus Tie Bus Parallel Unit USER MANUAL. Smartgen Technology

HGM9580 Bus Tie Bus Parallel Unit USER MANUAL. Smartgen Technology HGM9580 Bus Tie Bus Parallel Unit USER MANUAL Smartgen Technology This manual is suitable for HGM9580 bus tie bus parallel unit only. Clarification of notation used within this publication. SIGN INSTRUCTION

More information

HelmView 450 Model HV450. Operation Manual Section 78

HelmView 450 Model HV450. Operation Manual Section 78 HelmView 450 Model HV450 Operation Manual 00-02-0870 2015-04-16 Section 78 In order to consistently bring you the highest quality, full-featured products, we reserve the right to change our specifications

More information

Power Xpert Protection Manager for Eaton PXR 20/25 Trip Units. Quick Start Guide. Power Xpert Protection Manager Quick Start Guide Page 1

Power Xpert Protection Manager for Eaton PXR 20/25 Trip Units. Quick Start Guide. Power Xpert Protection Manager Quick Start Guide Page 1 Power Xpert Protection Manager for Eaton PXR 20/25 Trip Units Quick Start Guide Power Xpert Protection Manager Quick Start Guide Page 1 Table of Contents 1. Introduction... 4 2. Installation... 4 2.1 System

More information

3690 N.W. 53rd Street Fort Lauderdale, FL SC-2124 SC-2124M. 24 Channel Universal Scanner. Installation and Operation Manual P/N 145F-11902

3690 N.W. 53rd Street Fort Lauderdale, FL SC-2124 SC-2124M. 24 Channel Universal Scanner. Installation and Operation Manual P/N 145F-11902 3690 N.W. 53rd Street Fort Lauderdale, FL 33309 SC-2124 SC-2124M 24 Channel Universal Scanner Installation and Operation Manual P/N 145F-11902 Rev. 3.30 (c) Copyright 2000, Dynalco Controls All Rights

More information

SIGMA S6610 PM Module

SIGMA S6610 PM Module User s Manual Revision: 20/09/2010 SELCO A/S Betonvej 10 - DK-4000 Roskilde Denmark Phone: 45 7026 1122 - Fax: 45 7026 2522 e-mail: selco.dk@selco.com Web site: www.selco.com Table of Contents 1 Preface...

More information

SCC Inc. TS Series Application Guide. Technical Instructions. Document No. TS 8000 January 9, Description

SCC Inc. TS Series Application Guide. Technical Instructions. Document No. TS 8000 January 9, Description SCC Inc. Application Guide Technical Instructions January 9, 2018 Description The Application Guide includes programming, wiring, and operation examples of the control system for the most common applications.

More information

CLIQ Web Manager. User Manual. The global leader in door opening solutions V 6.1

CLIQ Web Manager. User Manual. The global leader in door opening solutions V 6.1 CLIQ Web Manager User Manual V 6.1 The global leader in door opening solutions Program version: 6.1 Document number: ST-003478 Date published: 2016-03-31 Language: en-gb Table of contents 1 Overview...9

More information

INSTRUCTION MANUAL. Web server description. AQ 300 Series

INSTRUCTION MANUAL. Web server description. AQ 300 Series INSTRUCTION MANUAL Web server description AQ 300 Series Instruction manual Web server description 2 (22) Revision 1.0 Date August 2013 Changes - N/A Instruction manual Web server description 3 (22) TABLE

More information

Installing the Cisco Unified Videoconferencing 3545 MCU

Installing the Cisco Unified Videoconferencing 3545 MCU CHAPTER 2 Installing the Cisco Unified Videoconferencing 3545 MCU The Cisco Unified Videoconferencing 3545 MCU works together with a Cisco Unified Videoconferencing 3545 EMP Enhanced Media Processor (EMP)

More information

Communicative controller for VAV systems

Communicative controller for VAV systems FCR015 Communicative controller for VAV systems Summary FCR015 is a communicative controller for heating and cooling panels and a VAV (variable air volume) damper. It measures temperature and CO 2 concentration

More information

InteliLite MRS17 Click Here to Learn More

InteliLite MRS17 Click Here to Learn More InteliLite MRS17 Click Here to Learn More Comprehensive Genset Controller Brief Description The InteliLite is a cost effective controller for generator sets in stand-by and prime power applications. The

More information

MConfigPro Configuration Software. Installation and Operations Manual Section 50

MConfigPro Configuration Software. Installation and Operations Manual Section 50 MConfigPro Configuration Software Installation and Operations Manual 00-02-0602 02-09-06 Section 50 In order to consistently bring you the highest quality, full featured products, we reserve the right

More information

Innovative Electronics for a Changing World. Charge Smart R1 MPPT 12V/24V Auto detect Mains and Solar Battery charger with Remote Network Monitoring

Innovative Electronics for a Changing World. Charge Smart R1 MPPT 12V/24V Auto detect Mains and Solar Battery charger with Remote Network Monitoring Innovative Electronics for a Changing World Charge Smart R1 MPPT 12V/24V Auto detect Mains and Solar Battery charger with Remote Network Monitoring INDEX 1. SYSTEM DESCRIPTION 2. SYSTEM WIRING 3. SYSTEM

More information

MYRIAD QLC 4-CHANNEL MONITOR/CONTROLLER INSTRUCTION MANUAL

MYRIAD QLC 4-CHANNEL MONITOR/CONTROLLER INSTRUCTION MANUAL MYRIAD QLC 4-CHANNEL MONITOR/CONTROLLER INSTRUCTION MANUAL VISIT OUR WEBSITE SIGMACONTROLS.COM MYR QLC MANUAL 013114 2 TABLE OF CONTENTS INTRODUCTION 3 Ordering Information Specifications Features WIRING

More information

VALCON EasyWriter Ver1.0E Manual

VALCON EasyWriter Ver1.0E Manual VALCON EasyWriter Ver1.0E Manual E05172-K00022-00 Published Dec.2010 Ver3-1.03 HKS Co., Ltd. Revision History Revision Date 2008/12/10 First Edition (Ver3-1.01) 2010/4/2 Second Edition (Ver3-1.02) 2010/12/22

More information

HAT560NC SERIES (HAT560NC /HAT560NBC) ATS CONTROLLER USER MANUAL

HAT560NC SERIES (HAT560NC /HAT560NBC) ATS CONTROLLER USER MANUAL HAT560NC SERIES (HAT560NC /HAT560NBC) ATS CONTROLLER USER MANUAL SMARTGEN (ZHENGZHOU) TECHNOLOGY CO., LTD. Chinese trademark English trademark SmartGen make your generator smart SmartGen Technology Co.,

More information

HGM9510 Genset Parallel (With Genset) Unit USER MANUAL. Smartgen Technology

HGM9510 Genset Parallel (With Genset) Unit USER MANUAL. Smartgen Technology HGM9510 Genset Parallel (With Genset) Unit USER MANUAL Smartgen Technology CONTENTS 1 OVERVIEW... 5 2 MODULES COMPARISON... 6 3 PERFORMANCE AND CHARACTERISTICS... 7 4 SPECIFICATION... 9 5 OPERATION...

More information

- NLS NAVIGATION LIGHT CONTROL

- NLS NAVIGATION LIGHT CONTROL Technical documentation - NLS 3000 - NAVIGATION LIGHT CONTROL For use on seagoing vessels Change status Version Date Author Checked Remark 0.1 07.08.2008 STO HN 1. Edition 0.2 29.09.2010 STO TK Changes

More information

Operating Instructions

Operating Instructions 33CS Comfort System Software CONTENTS Page GENERAL...1 OPERATION...1-11 Start-Up...1 Main Menu...2 CURSOR MOVEMENT AND FUNCTION SELECTION Initial Setup and Configuration...3 BASIC MODE EXPERT MODE MODEM

More information

DEEP SEA ELECTRONICS PLC

DEEP SEA ELECTRONICS PLC DEEP SEA ELECTRONICS PLC 5xxx series configuration software for Windows For 55xx series controllers. Authors Anthony Manton Deep Sea Electronics Plc Highfield House Hunmanby Industrial Estate North Yorkshire

More information

USER MANUAL. Modbus IHP24-A IHP24-AF IHP24-B IHP24-BF IHP24-F IHP24-I 1/26

USER MANUAL. Modbus IHP24-A IHP24-AF IHP24-B IHP24-BF IHP24-F IHP24-I 1/26 USER MANUAL Modbus IHP24-A IHP24-AF IHP24-B IHP24-BF IHP24-F IHP24-I 1/26 Table of contents 1 General... 3 1.1 Safety instructions... 3 2 Purpose... 4 3 Specifications... 5 3.1 Electrical specifications

More information

Series B9 and C9 Electronic Metering Pumps. Instruction Manual. Manual No : 1796 Rev. : D Rev. Date : 11/2015

Series B9 and C9 Electronic Metering Pumps. Instruction Manual. Manual No : 1796 Rev. : D Rev. Date : 11/2015 Series B9 and C9 Electronic Metering Pumps Manual No : 1796 Rev. : D Rev. Date : 11/2015 sales@novatech-usa.com www.novatech-usa.com Tel: (866) 433-6682 Fax: (866) 433-6684 Tel: (281) 359-8538 Fax: (281)

More information

E102 - Advanced Strain Gauge Transducer Display Interface. Contents

E102 - Advanced Strain Gauge Transducer Display Interface. Contents E102 - Advanced Strain Gauge Transducer Display Interface Contents Torque Transducer Display Interface: TSE3249R Strain Gauge Transducer Display Interface [E102] Operating Guide: TSE2098V (Includes Introduction,

More information

EMS-GC10 Genset Controller. Modbus Communication Mapping Manual Section 75

EMS-GC10 Genset Controller. Modbus Communication Mapping Manual Section 75 EMS-GC10 Genset Controller Modbus Communication Mapping Manual 1311311 2013-10-10 Section 75 In order to consistently bring you the highest quality, full featured products, we reserve the right to change

More information

INSTRUCTIONS MANUAL. ParaMon Software

INSTRUCTIONS MANUAL. ParaMon Software INSTRUCTIONS MANUAL ParaMon Software Index 1. Installation 1 1.1 Required PC specification 1 1.2 Software 1 2. Operation 2 2.1 Connection 2 2.2 Menu 2 2.2.1 System 4 1) Firmware downloader 4 2) Firmware

More information

Keyboard User s Manual

Keyboard User s Manual Keyboard User s Manual Version 1.0.0 1 Table of Contents 1 Features and Specifications... 7 1.1 Features... 7 1.2 Front Panel... 7 1.3 Rear Panel... 9 1.3.1 NKB1000 Series... 9 1.3.2 KB1000 Series... 9

More information

PowerView TM Model PV350 and PV380. Operations Manual Section 78

PowerView TM Model PV350 and PV380. Operations Manual Section 78 PowerView TM Model PV350 and PV380 Operations Manual 00-02-0879 2012-11-30 Section 78 In order to consistently bring you the highest quality, full featured products, we reserve the right to change our

More information

iologik R1200 Series User s Manual

iologik R1200 Series User s Manual User s Manual Edition 3.3, February 2018 www.moxa.com/product 2018 Moxa Inc. All rights reserved. User s Manual The software described in this manual is furnished under a license agreement and may be used

More information

BESTCOMSPlus Software

BESTCOMSPlus Software 9440300990 Rev P 123 General Description BESTCOMSPlus is a Windows -based, PC application that provides a user-friendly, graphical user interface (GUI) for use with Basler Electric communicating products.

More information

Quick Start Guide 4/8/16-CH DVR.

Quick Start Guide 4/8/16-CH DVR. Quick Start Guide 4/8/16-CH DVR 1. Install Hard Drive &DVD Writer 1.1 Install Hard Drive Notice: 1. Support two SATA hard drives. Please use the hard drive the manufacturers recommend specially for security

More information

V0STAT51P-2 Programmable Wired Controller

V0STAT51P-2 Programmable Wired Controller PRODUCT SPECIFICATIONS VARIABLE REFRIGERANT FLOW SYSTEMS VRF V0STAT51P-2 Programmable Wired Controller Bulletin No. 210766 March 2016 Grouping - Controller can control up to 16 indoor units on the same

More information