MARWELL CORPORATION Manufacturer of UL Listed Meter Socket Adapters
|
|
- Magnus Barton
- 5 years ago
- Views:
Transcription
1 Yellow Section Capacitor Sockets and Monitors, Temporary Service Adapters, Quick Set/Gen Set, Temporary Load Center, TSA, Transformer Load Management
2 CAPACITOR CONTROLLER SOCKET Four - Six Jaws Wire Lugs for #12-2 wire Specifications UL Recognized Marwell Housing. 600 VAC Rated. Aluminum Pole Bracket. Jaw lugs rated for # 12-2 cable or Screw terminals optional. Strain relief option chart: PG-21 PG-16 PG-13.5 PG inches inches inches inches Ground Lug Select the Strain Relief Ordering Instructions: Model SP L-BKT (shown) - Available in 4, 5 and 6 jaw models. - Lugs standard, screw terminals optional. - Available with or without strain relief. - Specify strain relief size if needed. - Hole optional for up to 1 inch conduit. - Pole mount bracket may be deleted. - Top or Bottom conduit holes.
3 CAPACITOR MONITOR AMI Capacitor Monitor Fixed or Switched Capacitor Banks AMI monitors can be used on all Fixed or Switched Capacitor Banks. The internal CT reads the current on the neutral bus of the CAP bank. Capacitor monitor has a built in 100:5 amp CT. This CT will be shorted by an internal switch when meter is removed. The AMI meter stores the hourly reading and transmits the data daily to a database. The AMI Monitor has a 3 4 plastic tube running inside the enclosure that goes thru the 100/5 amp ct. Tube for neutral sensing wire. 100/5 CT SHORTING SWITCH FOR CT
4 Temporary Service Adapter for 4/0 Cable Designed for one, two, or three cables - size 4/0 This special adapter will safely connect either one or two number 4/0 cables to the line side jaws of a meter socket. A 4/0 neutral may also be connected. Plugs are provided for the unused cable entrance holes. The adapter may be used as either a source or load device by lifting the existing service cables from the socket lugs. Adapter Specifications.! - Patented jaw for 200 Amp continuous duty. - All components UL LISTED or Ordering Instructions: UL Recognized. Conductor size - Weatherproof 6 X 8 X 5 inch deep enclosure. - Marwell 4-Bolt 1.5 x 2 non-metallic coupler. - Sealable and Lockable cover. - Supplied with two non-metallic tamper resistant plugs to close the unused cable entrance holes. Model 1800-TSA-4/0 4/0 for 4/0 cable 3/0 for 3/0 cable 2/0 for 2/0 cable Meter socket type 1000 for Ring style 1800 for Ringless style
5 QUICK-SET GENERATOR ADAPTER! This new version of the Marwell generator adapter is designed to be hard wired to a standby generator. Roll out the generator with adapter already connected, pull the meter, clip the neutral, and plug-in the adapter. Just two minutes and you are safely connected. Complete isolation, no back feed to the utility power grid. May be sealed with a standard meter ring. The quick way to connect a temporary generator MARWELL QUICK-SET! OPTIONS: 120V or 240V Wire size and length to specifications Wire end termination per customer Blunt cut wire end (None) Pre-stripped Twist-lock plug Straight blade plug Use the GEN-SET version for meter storage ORDERING INFORMATION: Contact Marwell and specify you requirements for either the QUICK-SET or GEN-SET adapter. Specify: Voltage Amp rating Wire length Wire end connection type GEN-SET with meter storage
6 Temporary Service Adapters LINE / LOAD TSA-2/0 Source Side TSA-2/0 Load Side Adapter Rated For 200 Amps MAX 160 Amps Continuous Maximum Conductor Size 2/0 AWG Line Side, 1/0 AWG Neutral Lug Adapter Rated For 160 Amps Max 135 Amps Continuous Maximum Conductor Size 2/0 # 2 AWG Neutral Lead With Heavy Duty Terminal End Hub Size 2 Polycarbonate Combined Load Rating Of Adapters Installed As A Pair 200 Amps Max, 160 Amps Cont. Line Side, 1/0 AWG Neutral Lug #2 AWG Neutral Lead With Heavy Duty Terminal End Hub Size 2 Polycarbonate Line Side Stabs Of Adapter Are Isolated From Metered Side Of Adapter. Line Side Only
7 TSA TEMPORARY SERVICE ADAPTERS Specifications * TSA-LINE Rated for 200 Amp continuous combined load. * TSA-LOAD Rated for 100 Amp continuous standard. Higher rating optional. * Each meter registers only one house. * Modified UL Listed adapter with UL Recognized components throughout. * Will not back feed the faulted cable. Temporary repair of failed underground. A large southern utility came to us for a heavy duty set of Temporary Service Adapters, something to help them connect jumper cables to a meter socket in the event of a failed service at a residence. The jumper cable is actually a length of #2 Triplex. The night emergency crew normally runs it on the ground to bring power into a home until a day crew can get back and make a proper repair. The adapters needed to be rugged for repeated reuse and the source adapter must be able to handle the high current load of two houses. The Marwell TSA is up to the task. The TSA-LOAD is attached to the end of the cable and inserted in the meter socket of the dark house. The TSA-LINE is attached to the other end of the cable and inserted in a neighbors house that has power. The meter in each adapter measures only the consumption of its respective home. Ordering Instructions: 1000-TSA-LINE Source adapter for ring style systems, 200 Amp continuous combined load 1000-TSA-LOAD Load adapter for ring style systems TSA-LINE Source adapter for ringless systems, 200 Amp continuous combined load 1800-TSA-LOAD Load adapter for ringless systems.
8 Transformer Load Management Adapter and Energy Diversion Mount the Marwell TLM Adapter at the transformer site and install Smart Meter. Use Smart Meter to collect and transmit data from transformer site. Marwell Corporation pole mounted Transformer Load Management adapter is available in two different current ratings in self-contained units. Marwell Part # TLM-2s-200A Rated 200 Amps Continuous, 600V rated. Marwell Part # TLM-2s-400A Rated 320 Amps Continuous, 600V
LED. Sign Module. Assembly Manual
LED Sign Module Assembly Manual 6/14/2002 3:10 PM 6 2 3 3 E. S a w g ra s s R d S a ra s o ta, F L. 3 4 2 4 0 (9 4 1 )3 7 7-5 7 7 5 F A X(9 4 1 )3 7 8-4 2 2 6 www.acscontrol.com Table of Contents Table
More informationMeter Enclosure and Equipment Standards
Meter Enclosure and Equipment Standards (a) (b) General Requirements: CITY OF OCALA UTILITY SERVICES METER ENCLOSURE AND EQUIPMENT STANDARDS: (1) To avoid the costs associated with having to replace unacceptable
More informationTECHKNOW, INC. Kiosk Order Confirmation System INSTALLATION MANUAL. Revision Date: July 11, 2012 Part # Version 3.2
document Page 1 of 18 TECHKNOW, INC Kiosk Order Confirmation System INSTALLATION MANUAL Revision Date: July 11, 2012 Part # Version 3.2 Techknow, Inc. 393 Mayfield Road Duncan, SC 29334 www.gotechknow.com
More informationGround Power Modules. And Accessories For Healthcare Facilities. Technical Bulletin NAE /
2 Ground Power Modules And Accessories For Healthcare Facilities Technical Bulletin NAE2092320 / 10.2011 Ground Power Modules Hospital grade outlet modules Introduction BENDER series GPM ground and power
More informationInstruction Manual: IM E
Innovative Technology TVSS Products The I.T. Equalizer Installation Instruction Manual: IM01005011E Rev. 2 May 2009 Contents Page 1 Introduction... 1 1.1 Scope... 1 1.2 I.T. Equalizer Catalog Numbering
More informationFT & RT Test Switches
GE Grid Solutions FT & RT Test Switches Key Benefits The FT Switches and FT Test Plugs have all the features necessary for applications involving the measurement of individual currents and voltages to
More informationSeries Amp Pad Mount Quick Connect Input and Output Power Panels
Series 300 2000-4000 Amp Pad Mount Quick Connect Input and Output Power Panels DANGER is used in this manual to warn of a hazard situation which, if not avoided, will result in death or serious injury.
More informationSquare D Meter Centers. A Comprehensive. Selection. Time-Saving, Reliable. Solutions
Square D Meter Centers A Comprehensive Selection of Time-Saving, Reliable Solutions VERSATILITY. DESIGN SUPERIORITY. SELECTION. Installation simplicity. The largest selection of meter centers in the industry.
More informationCOMPACT30 Warning Tower Lights - General Description...J17 Complete Assemblies...J19 Accessories...J20 Technical Information...J21
SIGNAL50 - General...2 Light Modules...4 Bulbs...5 Sound Modules...6 Mounting Bases...7 Accessories...9 Complete Assemblies...10 Technical Information...12 COMPACT30 - General...17 Complete Assemblies...19
More informationZenith Series DPB Distributed Power Busway
Critical Power from GE Zenith Series DPB Distributed Power Busway Key Solutions for Datacenter Overhead Power Distribution Generation 2 GE Series DPB Gen 2 Bus System Flexible. Robust. Efficient. Specifically
More informationInstallation Notes TII Model 341 Protector
Installation Notes TII Model 341 Protector (ATT-IS PEC 32918) for MERLIN Communications System In Range Out of Building (IROB) Station Installation By Trained Technician Only WARNING: Failure to follow
More informationTraceTek Leak Detection Master Module Installation Instructions TOOLS REQUIRED STORAGE
TTDM-128 TraceTek Leak Detection Master Module Installation Instructions TRACETEK APPROVALS AND CERTIFICATIONS TYPE NM General Signaling Equipment 76LJ GENERAL INFORMATION Please read these instructions
More informationInstalling a Power over Ethernet injector
Installing a Power over Ethernet injector AlphaEclipse StreetSmart and RoadStar signs The instructions in this document explain how to install/replace a Power over Ethernet (PoE) injector in a StreetSmart
More informationASCO SERIES 300 Manual Transfer Switch Solutions
ASCO SERIES 300 Manual Transfer Switch Solutions When power fails, businesses suffer. For some organizations, a permanent generator is too costly. Instead, permanent means for quickly connecting a portable
More informationPower-Style QED-2, Series 2 Low Voltage Switchboards
Power-Style QED-2, Series 2 Low Voltage Switchboards Catalog 2742CT1001 (Addendum to 2742CT9501R12/09) 2010 Class 2742 CONTENTS Description............................................. Page Features...................................................
More informationRS3000 SERIES BILL ACCEPTORS
Flash Diagnostic Codes RS3000 SERIES BILL ACCEPTORS INSTALLATION GUIDE s of the bill acceptor. Below is a chart that lists all the flash codes of the RS3000 Bill Acceptor and a description of each code.
More informationHaworth Power Technical Sheets January 2018
Haworth Power Technical Sheets January 2018 Includes Accessories This page intentionally left blank. Table of Contents Desk Top Port Power Tap Cord Power Tap Conduit Enchanced Power Module Flip Top Unit
More informationInstallation NOTICE. S&C IntelliCap Automatic Capacitor Control. Table of Contents. Instruction Sheet
S&C IntelliCap Automatic Capacitor Control Installation Table of Contents Section Page Section Page Introduction Qualified Persons.... 2 Read this Instruction Sheet.... 2 Retain this Instruction Sheet...
More informationNational Light Sources Pty Ltd Electrical Accessories - Date 8th April, Coombes Drive, Penrith, NSW, 2750 Australia
National Light Sources Pty Ltd 15 Coombes Drive, Penrith, NSW, 2750 Australia 15 Coombes Drive Penrith NSW 2750 Tel: 02-4732 5444 Fax: 02-4732 6600 Email: sales@nlslight.com.au Product list for Electrical
More informationSECTION SWITCHBOARDS
SECTION 26 24 13 PART 1 - GENERAL 1.1 SUMMARY A. Work Included: 1. Switchboards 2. Commercial Metering Switchboards 3. Non-Utility Power Meters (Microprocessor-Based Metering Equipment) PART 2 - PRODUCTS
More informationThe Leviton Load Center THE FUTURE MADE CURRENT
The Leviton Load Center THE FUTURE MADE CURRENT Raising the Bar Again For over 110 years, Leviton has cultivated a rich tradition of safety and innovation, developing electrical products that set the
More informationSECTION WIRING DEVICES PART 1 - GENERAL 1.1 RELATED DOCUMENTS
SECTION 26 27 26 - WIRING DEVICES PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification
More informationSECTION WIRING DEVICES
SECTION 16141 WIRING DEVICES PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,
More informationEPIC Circular Connectors CIRCON M23 Series
The M3 connectors have many inherent features which offer application advantages and provide significant benefits for the customer. These features make it one of the most application friendly connectors
More informationI-Line Panelboards. Innovative design, smart bus technology, and simple installation
I-Line Panelboards Innovative design, smart bus technology, and simple installation TM Smart: designed for efficient installation Simple: Efficient Installation Process I-Line Breakers Main Lugs: Fixed-mounted
More informationSection 21. Telecommunication Hardware. BuyLog Catalog 21-1
Introduction...21-1 Fiber Closure Hardware...21-2 Cable Location Surge Protectors...21-4 Introduction GE has been manufacturing Telecommunication Hardware products for over 20 years and has become a leader
More informationSPECIAL SPECIFICATION 1864 Pole Mounted Cabinet
1993 Specifications CSJ s 0924-06-221,etc. & 0924-06-223 SPECIAL SPECIFICATION 1864 Pole Mounted Cabinet 1. Description. This specification describes the minimum acceptable requirements for a weatherproof
More information1.2. Loadcenters and Circuit Breakers. Contents. Overview. Type BR Loadcenters and Circuit Breakers. Product Selection Guide.
.2 Overview Product Selection Guide BR Loadcenters Description Service Single-phase, three-wire, 20/240 Vac Short-Circuit Current Rating 0 kaic: All single- and three-phase loadcenters 70 225 A, 8 to 42
More information1.2. Loadcenters and Circuit Breakers. Contents. Overview. Type BR Loadcenters and Circuit Breakers. Product Selection Guide.
.2 Overview Product Selection Guide BR Loadcenters Description Service Single-phase, three-wire, 20/240 Vac Short-Circuit Current Rating 0 kaic: All single- and three-phase loadcenters 70 225A, 8 to 42
More informationPowering innovation. Powering efficiency. Powering home
Powering efficiency Powering home DISCONNECTS The best prices & selection in Siemens general, industrial & heavy duty safety switches for every application. Powering innovation Illustrating the diverse
More information1.2. Loadcenters and Circuit Breakers. Contents. Overview. Type BR Loadcenters and Circuit Breakers. Product Selection Guide.
.2 Loadcenters and Circuit Breakers Overview Product Selection Guide BR Loadcenters Description Service Single-phase, three-wire, 20/240 Vac Short-Circuit Current Rating 0 kaic: All single- and three-phase
More informationPlease Read Instruction Carefully Before Installation! Figure 1: A/CO2-DUCT
Installation and Operation Instructions A/CO2-DUCT Series Please Read Instruction Carefully Before Installation! Figure 1: A/CO2-DUCT PRECAUTIONS REMOVE POWER BEFORE WIRING. NEVER CONNECT OR DISCONNECT
More informationH704-42(H)(E), H704-42/1(H)(E)
POWER MONITORING INSTALLATION GUIDE H704-42(H)(E), H704-42/1(H)(E) Branch Current Monitor DANGER NOTICE Installer's Specifications General: Operating Temp. Range 0 to 60 C (32 to 140 F) (
More informationMASTERLINE Ultimate Hybrid High Voltage 4/12 (MLUH HV 4/12) blunt cut at BTS side
INSTALLATION MANUAL HUBER+SUHNER AG Fiber Optics MASTERLINE Ultimate Hybrid High Voltage 4/12 (MLU HV 4/12) blunt cut at BTS side DOC-0000803885 Rev A June 18, 2018 Page 1 of 12 (MLUH HV 4/12) blunt cut
More information3M Indoor Protected Building Entrance Terminal 4788V-QCS Series
The Network of Networks. 3M Indoor Protected Building Entrance Terminal 4788V-QCS Series with 3M Quick Connect System (QCS) 2811 Dry Flame Retardant Block for Field-Terminated Building Cables Instructions
More informationThis Datasheet for the IC697CHS790. Rack, 9 Slots, Rear Mount.
This Datasheet for the IC697CHS790 Rack, 9 Slots, Rear Mount. http://www.cimtecautomation.com/parts/p-14771-ic697chs790.aspx Provides the wiring diagrams and installation guidelines for this GE Series
More informationMLS7A Series. Photoelectric Sensors. Heavy-Duty Retro-Reflective Sensors. Photoelectric MLS7A Series Heavy Duty PEPPERL+FUCHS 529
Retro-Reflective Mode See page 53 Sensing Ranges: 3m Outputs: NPN MLS7A Series Heavy-Duty Retro-Reflective Sensors Heavy Duty Cast aluminium housing Side mount or flange mount Photoelectric MLS7A Series
More informationInstallation & Operation Manual
Via Enrico Fermi, 2 I-25015 Desenzano del Garda (BS) - Italy Phone: +39 030 7870787 Fax: +39 030 7870777 www.solexy.net BAF Intrinsically Safe Ethernet Coupler for signals operating in Hazardous Areas
More informationElectrical Management System (EMS) EMS-HW30C & EMS-HW50C
Electrical Management System (EMS) EMS-HW30C & EMS-HW50C Installation & Operating Guide for: Model EMS-HW30C Rated at 120V/30A and Model EMS-HW50C Rated at 240V/50A Surgio Says Lifetime Warranty on all
More informationSelf Contained - Non-Jaw Clamping Lever Bypass
Self Contained - Non-Jaw Clamping 125 Amp Continuous - 600 VAC Application Single meter position Designed for watt hour meters that meet ANSI C12.10 Overhead or underground feed Surface mount Construction
More informationIndustrial Electric Actuators AC and DC Voltages Nm/ inch lbs
Industrial Electric Actuators AC and DC Voltages 30-200Nm/265-1770 inch lbs Features Quarter turn (90 ) operation with mechanical travel stops Type 4X/IP67 weatherproof aluminum alloy enclosure Highly
More informationQuick Start Guide TS 870 ATS
Quick Start Guide TS 870 ATS 100A - 800A (with TSC 900 Controller) DANGER HAZARD OF ELECTRICAL SHOCK, EXPLOSION, OR ARC FLASH Read and understand this quick start guide before installing and operating
More informationSelf Contained - Non Lever Bypass
Self Contained - Non 125 & 200 Amp Continuous - 600 VAC Application Single meter position Designed for watt hour meters that meet ANSI C12.10 Overhead or underground feed Surface mount Construction Ringless
More informationnls Product List 1st February, 2014 Tel: Fax: Coombes Drive, Penrith, NSW, 2750 Australia
15 Coombes Drive, Penrith, NSW, 2750 Australia 15 Coombes Drive Penrith NSW 2750 Tel: 02-4732 5444 Fax: 02-4732 6600 Email: sales@nlslight.com.au Product list for Electrical Accessories Code Item Inner
More informationEMS. Electrical Management System. Progressive Industries Incorporated Morrisville, North Carolina
Progressive Industries Warranty Progressive warrants its products are free from defects in materials and workmanship for a period of three years. This is in lieu of all other warranties, obligations, or
More information1993 SPECIFICATIONS CSJ , ETC. & SPECIAL SPECIFICATION ITEM 6132 ARTERIAL TRAFFIC MANAGEMENT SYSTEM
1993 SPECIFICATIONS CSJ 1685-05-068, ETC. & 1685-02-042 1.0 DESCRIPTION SPECIAL SPECIFICATION ITEM 6132 ARTERIAL TRAFFIC MANAGEMENT SYSTEM THIS ITEM DESCRIBES THE OPERATION AND INSTALLATION OF AN ARTERIAL
More informationSummary of shell housings and accessories Shell housing A Shell housing D EMC housing
Directory chapter 20 Page Summary of shell and accessories........................... 20.02 housing C.......................... 20.04 housing A................................................. 20.08 housing
More information3M Indoor Building Entrance Terminal (IBET) 4790V and 4790VL Series
3M Indoor Building Entrance Terminal (IBET) 4790V and 4790VL Series with 3M Quick Connect System (QCS) 2811 Dry Flame-Retardant Block and RJ-11 Test Ports Instructions Underwriters Laboratories (UL 348X)
More informationInstallation Guide. Retrofit Kit for USB Ready Intraoral Systems
Installation Guide Retrofit Kit for USB Ready Intraoral Systems Table of Contents Wall-Mount Retrofit Kit... 2 Introduction... 2 Connecting the Articulating and Horizontal Arm Cables... 2 Installing the
More informationSECTION DISCONNECT SWITCHES
SECTION 16440 DISCONNECT SWITCHES PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and other Division 01 Specification
More informationCompact, Low Profile High Rendering, 100% Diffusion
SURFACE MT SERIES PRELIMINARY SPECIFICATION, SUBJECT TO CHANGE WITHOUT NOTICE MT Series Compact, Low Profile High Rendering, 100% Diffusion Trimless, No Visible Hardware Trimless appearance for recessed
More informationSeries Amp Quick Connect Input and Output Power Panels
Series 300 1200-1600 Amp Quick Connect Input and Output Power Panels DANGER is used in this manual to warn of a hazard situation which, if not avoided, will result in death or serious injury. WARNING is
More informationM12 Field Wireable Connectors. M12 CAT.6A Field Wireable Connectors. M12 Field Wireable Connectors for PROFINET
M12 Connectors Application Advantage Shielded design ETHERLINE Ethernet Cable, Connectors & Tools M12 Field Wireable Connectors Male Female Temperature Range: Max. 85 C Nominal Voltage: Nominal Current:
More informationWINSTA. Full Line Catalog 2008/2009
WINSTA Full Line Catalog 2008/2009 5 Contents FULL LINE CATALOG W4, Volume 1 Rail-Mounted Terminal Block Systems FULL LINE CATALOG W4 Rail-Mounted Terminal Blocks Volume 1 X-COM -SYSTEM Terminal Strips
More informationInstruction Manual. Electrical Management System (EMS) EMS-HW30C & EMS-HW50C
Instruction Manual Electrical Management System (EMS) EMS-HW30C & EMS-HW50C EMS-HW50C EMS-HW30C! CAUTION These instructions are intended to provide assistance with the installation of this product, and
More information1. Mount the echo and tremolo control switches under the keyboard shelf, in a position convenient for the organist.
CONSOLE CONNECTOR KIT 8101 INSTALLATION INSTRUCTIONS FOR USE WITH: HAMMOND Organ Models A-100, D-100, RT2, RT3 LESLIE Speaker Models 122, 122RV KIT CONTENT Console Connector Assembly 047357 Echo Control
More informationPosi-Lok Plugs and Panels
THE SAFEST ELECTRICAL SYSTEM FOR HIGH AMPERAGE CONNECTIONS, POSI-LOK IS PART OF THE CAM-LOK FAMILY OF CONNECTORS. THE GROUND ALWAYS MAKES FIRST AND BREAKS LAST ALL POSI-LOK SYSTEMS ARE UL LISTED AND CSA
More informationCarbon Monoxide (CO) Gas Detection and Control System
Carbon Monoxide (CO) Gas Detection and Control System DESCRIPTION Gas monitor with built-in carbon monoxide (CO) sensor, wall-mounted, accepts inputs from remote devices such as other gas sensors, temperature
More informationFDS / FDS-R / FDS-PS
FDS / FDS-R / FDS-PS USER MANUAL For use with 120V 60Hz input. Output is 120V 60Hz at 5amps 600W MAX. switched. ETL LISTED Conforms to UL STD 1241 3091594 79-15167-00 REV. A www.fiberstars.com Page 1 of
More informationMounting Accessory Guide
Apr. 12 2010 Table of Contents Mounting Accessory Guide 1 Overview 5 Introduction... 5 Types of Mounting Methods... 5 Surface... 5 Wall... 5 L-Type Wall Mount (PMAX-0308) 6 Heavy Duty Wall Mounts (PMAX-0305
More informationIllinois and Northwest Indiana Metering Equipment
Illinois and Northwest Indiana Metering Equipment Technical Focus TD00000E Servicing : Ameren UE, Commonwealth Edison, Ameren IP (Illinois Power Utility), Northern Indiana and Public Service (NIPSCO) Illinois
More informationThe Leviton Load Center THE FUTURE MADE CURRENT
The Leviton Load Center THE FUTURE MADE CURRENT Raising the Bar Again For over 110 years, Leviton has cultivated a rich tradition of safety and innovation, developing electrical products that set the
More informationB Y R N E 8 - T R A C O V E R V I E W. 1) Introduction. 2) Universally Recognized. 3) Circuitry/Keying
Page 1 of 6 B Y R N E 8 - T R A C O V E R V I E W 1) Introduction Byrne Electrical Specialists, Inc. provides quality, cost effective, innovative power/data distribution solutions. From initial concept
More information1.2. Loadcenters and Circuit Breakers. Contents. Overview. Type BR Loadcenters and Circuit Breakers. Product Selection Guide.
.2 Loadcenters and Circuit Breakers Overview Product Selection Guide BR Loadcenters Description Service Single-phase, three-wire, 20/240 Vac Short-Circuit Current Rating 0 kaic: All single- and three-phase
More informationOvervoltage Protection
Overvoltage Protection Weidmuller has a complete line of overvoltage protection devices to effectively stop the harmful effects of electrical overvoltage and electrical noise. There is strong potential
More informationAC300/AC400 SERIES DYNAMIC BRAKING and ADDITIONAL FORM C RELAY. INSTALLATION INSTRUCTIONS Document Number:
Minarik Variable Speed AC Motor Drives AC300/AC400 SERIES DYNAMIC BRAKING and ADDITIONAL FORM C RELAY INSTALLATION INSTRUCTIONS Document Number: 250-0297 These instructions apply to models rated: 7.5 25
More informationpage 28 page 30 page 30 page 31
25 Gardner Bender switches are available in many different styles and sizes. They are used in countless applications, from basic on-off to multifunction applications. page 28 page 30 page 30 page 31 _Section_0512.indd
More informationrevos revos Industrial Multipole Connectors 3 48 pole in metal housing Program for Tough Tasks
revos Industrial Multipole Connectors 3 8 pole in metal housing Program for Tough Tasks Heavyduty industrial plug connectors for all applications The heavyduty industrial plug connectors revos are classified
More information6000 Series Buccaneer. 30 twist locking Tamperproof lock prevents accidental un-mating. Cat 5e shielded coupler Maintains shielding
circular connectors that combine the ease of use of a push/pull coupling mechanism with proven environmental sealing. Available with metal or plastic bodies, the range supports both data (USB and Ethernet),
More informationBulletin 800Z Zero-Force Touch Buttons
Bulletin 800Z Zero-Force Touch Buttons IEC and NEMA Style General Purpose Range Heavy Industrial Range Protection Class 4/4X/3 and 4/3 IP66 Internationally Rated Ergonomically Designed Touch Buttons Table
More informationProgram B3 318 Ø 22,5mm. Push Buttons 319 EMERGENCY STOP Buttons 320 Key Operated Rotary Switches 320
Push Buttons Index Page Program B3 318 Ø 22,5mm Push Buttons 319 EMERGENCY STOP Buttons 320 Key Operated Rotary Switches 320 Rotary Knobs and Swing Knobs 321 Illuminated Rotary Knobs and Swing Knobs 321
More informationalid portable power cart epcc panel ccts EPCC-60 40" 60A, 120/208V 3PH 24 EPCC " 100A, 120/208V 3PH 24
portable power cart epcc Features/Specifications 12GA Steel construction CSA Type 3R rated Pin & Sleeve inlet connector Pad-lockable door Up to12 receptacles Cut-out in bottom to provide while-in-use Polyurethane,
More information7000 SERIES Power Switching Solutions. Closed Transition Transfer Switching. Delayed Transition Transfer Switching
7000 SERIES Power Switching Solutions Fig. 2: Four pole, Closed Transition Switch rated 1000 Amperes in Type 1 enclosure. Closed Transition Switching Closed Transition Switches feature main contacts that
More informationAI-102. IR Illuminator. Installation Guide. Rev IP Surveillance
AI-102 IR Illuminator Installation Guide Rev. 1.1 IP Surveillance Revision History: Rev. 1.0: Initial release Rev. 1.1: Changed effective IR range and power consumption. AI-102 Tube Type Infrared Illuminator
More informationMICHIGAN DEPARTMENT OF TRANSPORTATION
MICHIGAN DEPARTMENT OF TRANSPORTATION SPECIAL PROVISION FOR GROUNDING, BONDING, LIGHTNING PROTECTION AND SURGE PROTECTION FOR INTELLIGENT TRANSPORTATION SYSTEM EQUIPMENT ITS:CLC 1 of 5 APPR:LWB:DBP:07-31-13
More informationAdvantages of a Full Featured 700 Series Relay
SECTION 1 Advantages of a Full Featured 700 Series Relay Since the launch of the 700 series relays in 2000, this product line has continuously evolved both functionally and visually. The 700 series product
More informationMulti-Point Gas Detection and Control System
Multi-Point Gas Detection and Control System DESCRIPTION Wall mounted, microprocessor-based, multi-point, analog electronic control system for various gas, temperature and humidity detection, control and
More informationIntelligent-Remote Monitoring (3) Environmental Port (4) Power Outlet Level (5)
Faster. Enclosure Power Distribution Units (PDUs) (continued) PDU Selection: Basic, with Local and Intelligent PDU mounted display option for local current or power monitoring, making phase balancing easier
More informationTOPJOB S Sensor/Actuator Terminal Blocks with Push-in CAGE CLAMP Reliability
TOPJOB S Sensor/Actuator Terminal Blocks with Push-in CAGE CLAMP Reliability TOPJOB S SEND THE RIGHT SIGNALS. TOPJOB S Sensor/Actuator Terminal Blocks with Push-in CAGE CLAMP Reliability TWO IN ONE. WITH
More informationimac Intel 21.5" Retina 4K Display Power Supply Replacement
imac Intel 21.5" Retina 4K Display Power Supply Replacement Replace the power supply in a 21.5" Retina 4K Late 2015 imac EMC 2833. Written By: Evan Noronha ifixit CC BY-NC-SA www.ifixit.com Page 1 of 24
More informationPHOENIX CONTACT Pin. SUBCON-PLUS M ARCNET, MULTI/MININET (B&R), SYSTEM 2003 (B&R), P-NET SUCONET K1, K2 (EATON/Moeller),
Fast connector with screw terminal block connection for fieldbus systems Data sheet 00287_en_02 PHOENIX CONTACT 207-04-2 Description The SUBCON-PLUS/... D-SUB series is specifically designed for use in
More informationYour Global Flow Control Partner. Series 50 Valve Status Monitor Operation and Maintenance Manual
Your Global Flow Control Partner Series 50 Valve Status Monitor Table of Contents 1. Definition of Terms... 2 2. Safety... 2 3. Storage... 3 4. Commissioning... 3 4.1. Mounting your VSM... 3 4.2. Wiring
More informationZenith Series DPB. Distributed Power Busway
Zenith Series DPB Distributed Power Busway Touching all Areas of the Energy Industry GE s diverse portfolio of products and services is helping customers solve problems every day. We touch all areas of
More informationThree Phase Residential Solution for Australia, System Design and Installation Guidelines
Three Phase Residential Solution for Australia, System Design and Installation Guidelines This document describes how to design and install SolarEdge three phase inverters for residential installations.
More informationPANELITE ENCLOSURE LIGHTS OVERVIEW
SPEC-00581 H763.422.2211 763.422.2600 ELECTRICAL LIGHTING PACKAGES ELECTRICAL LIGHTING PACKAGES PANELITE ENCLOSURE LIGHTS OVERVIEW FEATURES Slim profile allows light to be tucked up out of the way for
More informationEcoFlex LED Neon Manual
Manual Part number: LN-ECO-XXXX-10m from Environmental Lights is one of the most flexible and cost-effective members of our line of LED Neon products. It allows you to achieve the creative potential of
More informationFCC17 Series FILTERED STACKED D-SUB CONNECTORS
FCC17 Series FILTERED STACKED D-SUB CONNECTORS Ordering Information Stacked D-Sub FCC17 2 BP BS 4 5 5 X FCC17 2 VERTICAL MOUNTING DIMENSION BETWEEN CONNECTORS 1 =.625" [15.88 mm] 2 =.750" [19.05 mm] BP
More informationPanelFAST. Setting a new standard for immediate product availability with Square D Ready to Install (RTI) Panelboards
PanelFAST Setting a new standard for immediate product availability with Square D Ready to Install (RTI) Panelboards Whether you planned ahead or have an unexpected project, why wait? You should expect
More informationInstalling the DX LCD Display
DX LCD Display User s Guide 3-1 Chapter 3 Installing the DX LCD Display Introduction Use the DX LCD Display as either a portable device, or permanently mount it in a panel or on the wall. For panel and
More information62GB. Amphenol Series 62GB. Applications. Features
Applications Features 62GB Amphenol 62GB Series connectors are built to British Standard Specification BS 9522 F00 17 which is similar to US military specification MIL-DTL-26482. They are machined from
More informationM215 Microinverter Installation Planning
TECHNICAL BRIEF M215 Microinverter Installation Planning The M215 Microinverter The M215 Microinverter is a powerful and efficient grid-tied microinverter. It is compatible with most 60- cell PV modules
More informationsonnen Installation Practical
sonnen Installation Practical sonnen Components sonnenbatterie eco 8.0 Single Phase System Components 4 sonnenbatterie eco 8.0 Single Phase System Components 5 sonnenbatterie eco 8.0 Single Phase System
More informationTerminal Blocks - Single Row. Series A3000, LP3000 & CB3000 Single Row Terminal Blocks
Series A3000, LP3000 & CB3000 Single Row Terminal SPECIFICATIONS Rating: A3: 30A, 600V* #12-22 AWG LP3: 30A, 150V #12-22 AWG CB3: 30A, 600V #12-22 AWG Wire Range: #12-22 AWG CU Center Spacing: 0.437 or
More information10 Pg C1 - C-30.qxp 6/9/ :43 AM Page C1. BELL Weatherproof Boxes, Covers, and Lighting
10 Pg C1 - C-30.qxp 6/9/2008 10:43 AM Page C1 BELL Weatherproof Boxes, Covers, and Lighting 10 Pg C1 - C-30.qxp 6/9/2008 10:43 AM Page C2 C2 pq^ka^oapi=ommu=k^qflk^i=bib`qof`^i=`lab Δ pí~åç~êçë _Éää Δ
More informationTelephony Multi-Taps. 9000T-TP Series
9000T-TP Series The 9000T-TP series 1 GHz twisted-pair power multi-tap taps off part of its input RF and AC, but lets the rest pass through. It divides the tapped-off signal and power into multiple outputs,
More informationHan-Brid. Contents Han-Brid Features Han-Brid Data interfaces Han-Brid Overview Han-Brid Cu
Contents Page Features... 19.02 Data interfaces... 19.03 Overview... 19.04 Cu... 19.06 F.O.... 19.08 Quintax 3 A... 19.10 RJ45 C... 19.12 USB / FireWire... 19.14 Han 4 A SC... 19.16 Hoods/Housings... 19.18
More informationUniversal Keying Adapter 3+
Universal Keying Adapter 3+ The Universal Keying Adapter Version 3+ kit will allow you to key nearly any transmitter or transceiver with a straight key, electronic keyer, computer serial or parallel port
More informationINSTALLATION INSTRUCTIONS
LIGHTING CONTROL PANELS 16 AND 24 RELAYS INSTALLATION INSTRUCTIONS INSTALLATION OVERVIEW The installation instructions contained in this document are provided as a guide for proper and reliable installation.
More informationFor (2) Single Receptacles: dia. Hole Standard Depth
6000 Series - Portable Outlet Boxes 6002 NOTICE: The NEC restricts the use of metal job boxes as temporary power cords 6000 6000 Series Portable Outlet Boxes Rugged and durable, these outlet boxes are
More informationLinearray PD Retrofit Kit
Linearray Retrofit and Installation Instructions 1. Scope All Installations should be performed by qualified personnel and all electrical work should be performed in accordance to NEC and local code. These
More information