1 Remote RMM-1400 Intelligent Remote Site Management Device Guide INSTALLATION GUIDE Westell Technologies Part # Rev. A
2 Copyright 2015 by Westell Technologies. All Rights Reserved. Westell, Kentrox and Optima Management System are registered trademarks of Westell. All other names are trademarks of their respective owners. Information is correct at time of publication and is subject to change without notice. Contact Westell in Aurora, IL, to verify current product information. Westell Inc. is an Equal Opportunity/Affirmative Action employer. Westell Technologies 750 North Commons Aurora, IL USA Toll Free: (800) International: +1 (630) Fax: +1 (630) Page 0
3 Remote RMM-1400 Intelligent Remote Site Management Device Guide This installation guide explains how to install the Remote RMM-1400 intelligent remote site management device. Instructions for use of this product are detailed in the following documents: Remote RMM-1400 Command Reference Guide Remote RMM-1400 Configuration Guide Guide to this document Product Components Cautions and Warnings Customer Assistance Required Items Technical Specifications Page 1
4 Product Components Product Components Front Panel Components - Remote RMM-1400 Unit Status LEDs LED Status LED Description ALM Summary alarm LED: Illuminates when any point is in alarm state FLT Hardware failure LED: Illuminates when processor is not functioning, or when RMM-1400 has been powered up and bootloader is loading Blinks when bootloader has loaded and kernel is loading Tx/Rx SMA Female Cellular/PCS Antenna Diversity SMA Female Cellular/PCS Antenna DC Goes out when RMM-1400 bootup is complete DC Input Power LED: Illuminated when valid DC input power is applied to the unit ESD Ground Chassis Ground Asynchronous Serial Ports Serial ports 1 and 2 operate only in RS-232 mode. Serial ports 3 and 4 operate in RS-422 mode or RS-485 mode. Ethernet Switch Ports Input Power and Battery Monitor Connections Ethernet ports 1 and 2 provide PoE for RMBs. Pins 1 and 2 (Rx) provide negative (-) output. Pins 3 and 6 (Tx) provide positive (+) output. Page 2
5 Cautions and Warnings Cautions and Warnings Grounding and Electrical Safety CAUTION: Kentrox equipment and peripherals contain electrostatic sensitive components. Proper handling, shipping, and storage precautions must be exercised. CAUTION: For Kentrox equipment to operate safely and correctly, there must be a safety ground strap between the equipment ground bolts and the office ground. Environment CAUTION: In the event that Remote RMM-1400 has been subjected to adverse environmental conditions, a service inspection of Remote RMM-1400 should be made to ensure safe operation. Restricted Access Locations CAUTION: The Remote RMM-1400 is for use in restricted access locations only. FCC The Federal Communications Commission has set limits for emitted radio interference, and Remote RMM-1400 is constructed with this electromagnetic interference (EMI) limitation in mind. Remote RMM-1400 is classified under FCC regulations as a Class A device, that is, a device for use in commercial environments and not in residential areas. This device has been tested and shown to comply with the following FCC rule: Part 15 Subpart J. Operation of this equipment in a residential area may cause interference to radio and TV reception, requiring the user to take whatever steps are necessary to correct the interference. Information is available from the FCC describing possible corrective actions. To maintain low EMI levels, we suggest that you use only metal connectors and shielded cable grounded to the frame. Specifications are subject to change without notice. Page 3
6 Customer Assistance Customer Assistance All customers, partners, and resellers who have a valid Westell Support and Services Agreement have complete access to the technical support resources. Pre-sales Support Westell offers pre-sales technical support from 9 a.m. to 5 p.m. Eastern time, Monday - Friday. Representatives are standing by to assist with customer account information and product ordering and answer questions regarding Westell products and solutions. Phone number: , option 1 Before you call or Before you contact Westell for assistance, please have the following information available: The versions of hardware and software you are currently running The error number and exact wording of any messages that appeared on your screen What happened and what you were doing when the problem occurred How you tried to solve the problem Technical Support support is available. You may send at any time during the day; however, responses will be provided only during normal business hours, in accordance with your Service and Support Agreement. To contact Technical Support, send to: support@westell.com Telephone Technical Support Available to qualified Westell customers or partners who have not been able to resolve their technical issue by using our online services. To qualify for support, you must have a valid Support and Services Agreement. Phone number: , option 2 Normal Business Hours: 8 a.m. to 6 p.m. Eastern time After-Hours Support: Available to qualified customers who are experiencing serviceaffecting outages that cannot wait until the next business day. To qualify for after-hours support, you must have a valid 24x7 Support and Services Agreement. Call the number above, option 2, and follow the prompts for after-hours service. Page 4
7 Customer Assistance Product Documentation You can also access and view the most current versions of Kentrox product documentation on our web site at: Page 5
8 Required Items Required Items Tools Materials #2 Phillips screwdriver Small flathead screwdriver (Phoenix 3 mm, recommended) 3/32 in. slotted screwdriver Crimping tool Wire cutter Wire stripper Grounding wrist strap Voltmeter, DC range PC or laptop with Kentrox Redirect software installed 10mm nut driver Wire punchdown tool (provided with RMB) Screws, sized to fit your rack Wire for input power connections (16 AWG solid or stranded insulated) Wire for ground connection (14 AWG, copper conductor) Ground lugs for rack or other earth ground Antioxidant Various required rack cables and cable assemblies Page 6
9 Step 1: Install Wireless Phone Module Hardware in Remote RMM-1400 If your Remote RMM-1400 includes the wireless phone module, follow these steps to install the necessary hardware: 1. Affix the FCC sticker (included with the phone module) to the product label on Remote RMM Remove the top cover from Remote RMM-1400 by removing two screws from each side panel, then sliding the top cover to the rear of the unit to release the locking flange as shown below. Lift the top cover off the unit. Locking Flange Mounting Screws (left side - second screw Mounting Screws (right side) CAUTION: Kentrox equipment and peripherals contain electrostatic sensitive components. Proper handling precautions must be exercised. 3. Install two antenna terminals by inserting them through the holes provided in the front of Remote RMM Secure the terminals in place by attaching a nut and lock washer to each terminal, as shown below. 4. Install the phone module by inserting one end in the socket on the motherboard. Next, press down the other end of the phone module until it locks in place. Page 7
10 5. Attach two antenna leads from the antenna terminals to the phone module as shown below. 6. Insert the SIM chip in the socket on the motherboard. 7. Reinstall the Remote RMM-1400 top cover by placing the top cover on the chassis, sliding it forward until the flange locks under the faceplate, then reinserting two screws in each side panel. Nuts Antenna Terminals Lock Washers Antenna Leads Phone Module SIM Chip Page 8
11 Step 2: Attach Mounting Flanges to Remote RMM-1400 Attach the mounting flanges to fit a 19-inch or 23-inch rack. You can attach the flanges in alternate locations providing multiple alignment options to the rack. Mounting flanges oriented for a 19-inch rack Mounting flanges oriented for a 23-inch rack Page 9
12 Step 3: Attach Remote RMM-1400 to Rack Install mounting screws into the mounting holes and tighten firmly. No space is required between Remote RMM-1400 and any component mounted above or below Remote RMM Page 10
13 Step 4: Attach Chassis Ground Connect the chassis ground of Remote RMM-1400 to a suitable ground such as the frame ground of the rack system or a reliable earth ground. Caution: The chassis ground must be connected to the same earthing electrode conductor as the DC supply system or to a bonding jumper (from an earthing terminal or bus) connected to the earthing electrode of the DC supply system. The chassis must be located in the same immediate area (such as adjacent cabinets) as other equipment connected to the same DC power system and earthing electrode conductor. The DC system cannot be earthed elsewhere. The DC power source must be located in the same premises as the chassis. No switching or disconnecting devices can occur between the earthed conductor of the DC source and the earthing electrode conductor. Note: Apply an appropriate antioxidant to the bare conductors before crimping the connector to the connector mating surface. Note: For ground connection, use 14AWG or larger conductor. Page 11
14 Step 5: Connect Input Power WARNING: Turn off the power feed before connecting wires. Connect the input power feed to the power supply connector. Be careful to observe polarity. Caution: A readily accessible disconnect device (suitably approved and rated) must be incorporated in the field wiring. Unscrew these two screws to remove the power connector, if necessary. To connect wires: 1. Turn off power feed. 2. Strip ends of wire 5/16 in. (7 mm). 3. (optional) Using a small flathead screwdriver, loosen screws on sides of power connector on rear panel of Remote RMM (optional) Remove power connector. 5. Using a 3/32 in. slotted screwdriver, loosen the six screws at top of connector. 6. Insert wire into connector and tighten screws. Notes: : Connect power connector to a reliably grounded -48 VDC safety extra-low voltage (SELV) source. Use 16 AWG or larger copper conductors. Typical circuit fuse: 3 A Page 12
15 Step 6: Mount RMB Mount the RMB peripheral unit to the wall, or in a rack. See the RMB Guide for instructions. Step 7: Connect RMB Inputs and Outputs RMB input and output connections are made using the supplied punchdown tool. See the RMB Guide for an explanation of RMB inputs and outputs. Step 8: Connect the Port Cables Connect all port cables per your application. Connecting RMM-1400 to RMB Use a standard CAT5 Ethernet cable (such as Kentrox part number CAB182-10) to connect one of RMM-1400 s PoE-enabled Ethernet ports to the Ethernet port on RMB. CAUTION: Kentrox recommends disconnecting the Ethernet PoE cable to RMB before wiring inputs and outputs in order to avoid electrical shorts. Connecting to an Asynchronous Serial Port Asynchronous serial ports allow terminal devices with asynchronous serial ports (such as PCs, NEs, and asynchronous modems) to connect to Remote RMM Use one of the following cables to connect one of the asynchronous serial ports (labeled SERIAL on the front panel) to an external device, such as a modem: 8-pin modular plug to 8-pin modular plug rollover DTE to DTE null RS-232 cable (part number CAB213) Male DB-25 to 8-pin modular plug DTE to DCE straight cable (part number CAB214) Female DB-25 to 8-pin modular plug DTE to DTE null RS-232 cable (part number CAB564) Female DB-9 to 8-pin modular plug DTE to DTE null RS-232 cable (part number CAB562) Note: Use shielded cable to ensure compliance with applicable emission standards. Connecting to a Switched Ethernet Port The switched Ethernet ports allow you to connect Ethernet-capable devices to Remote RMM-1400 and allow you to connect Remote RMM-1400 to a LAN. Use an 8-pin modular plug to 8-pin modular plug straight 100BaseT cable (such as Kentrox part number CAB182) to connect one of the switched Ethernet ports (labeled Page 13
16 ETHERNET on the Remote RMM-1400 front panel) to an Ethernet device on your network. Connecting Wires to RMB Punchdown Terminals To connect a wire to a punchdown terminal on RMB-1 or RMB-2: 1. Insert the wire in the slot in the top of the punchdown terminal and hold it in place. 2. Place the metal blade of the punchdown tool on top of the wire and press down firmly until the wire is seated in the bottom of the terminal. This action secures the wire in place and strips insulation from the wire. Pre-stripping the wire is not necessary. 3. Trim away any excess wire. 4. (optional) Gently tug the wire to ensure it is securely connected to the terminal. Step 9: Configure an IP Address Configuring the IP address allows Remote RMM-1400 to be accessed remotely. To configure the IP address: 1. Install Kentrox Redirect software on your laptop or PC. When the installation is complete, Kentrox Redirect and Kentrox Kickstart icons appear on your desktop. 2. Use a standard CAT5 Ethernet cable (such as Kentrox part number CAB182-10) to connect the PC or laptop to an Ethernet port on Remote RMM Launch Kentrox Kickstart. Kickstart discovers the Remote RMM-1400 device, as shown below. Note: If the Remote RMM-1400 device is not discovered within one minute, select Help > About in Kentrox Kickstart, then click the Network Troubleshooting Guide link for instructions. 4. Click Telnet Terminal (or select Tools > Telnet Terminal). A Telnet window opens, displaying the Remote RMM-1400 login prompt. Page 14
17 Technical Specifications 5. At the Remote RMM-1400 login prompt, enter admin. This is the default login. 6. At the password prompt, enter password. This is the default password. 7. At the command prompt, enter config interface bridge switch ip address, followed by the IP address and subnet mask. For example: config interface bridge switch ip address At the command prompt, enter config ip route default and the default gateway address. For example: config ip route default Technical Specifications Table 1 Technical Specifications Specification Weight Size Mounting Operating Environment (Ambient) Power Fuse Ratings Input/Output Ports Description 3.35 lb (1.5 kg) Height: 1.6 in. (4.1 cm) Width: 11.8 in. (30.0 cm) Depth: 8.6 in. (21.8 cm) Mounts in a standard 19-in. or 23-in. rack Temperature: -30 to 60 C (-22 to 140 F) Relative humidity: 0% to 95% (non-condensing) Dual input (A/B feed), 40 watts maximum Input voltage range: +/- 20 to 60VDC (both power feeds must have the same polarity) In-rush: 3A maximum - no greater than 2A for no longer than 2ms 3 A at 60 VDC 4 10/100 BaseT Ethernet switch ports, 2 with PoE for RMB Peripheral Units 2 RS-232 asynchronous serial ports 2 RS-422/RS-485 asynchronous serial ports VDC power inputs with voltage monitoring 1 auxiliary 0-60 VDC voltage monitoring input Page 15
INSTALLATION GUIDE. Remote RMM-700 Intelligent Site Management Device. Installation Guide WESTELL.COM
Remote RMM-700 Intelligent Site Management Device Guide INSTALLATION GUIDE Westell Technologies April 2015 Part # 030-300653 Rev. A Copyright 2015 by Westell, Inc. All Rights Reserved. Westell, Kentrox,
More informationRMB Peripheral Units Installation Guide
RMB Peripheral Units Installation Guide Part Number 65-000101 2011 by Kentrox, Inc. All rights reserved. Copyright 2011 by Kentrox, Inc. All Rights Reserved. The material discussed in this publication
More informationRMB-3 Peripheral Unit. Installation Guide INSTALLATION GUIDE WESTELL.COM. Westell Technologies Part # Rev. A
RMB-3 Peripheral Unit Installation Guide INSTALLATION GUIDE Westell Technologies Part # 030-300812 Rev. A Copyright 2017 by Westell Technologies. All Rights Reserved. The material discussed in this publication
More informationINSTALLATION GUIDE. Remote RMM-800 Intelligent Site Management Device. Installation Guide WESTELL.COM
Remote RMM-800 Intelligent Site Management Device Guide INSTALLATION GUIDE Westell Technologies July 2016 Part # 030-300731 Rev. C Copyright 2016 by Westell, Inc. All Rights Reserved. Westell, Kentrox,
More informationAI130 AIswitch Series 130 Chassis Installation Guide
AI130 AIswitch Series 130 Chassis Installation Guide Part Number QR-130 Rev 3 2007 by Kentrox, Inc. All rights reserved. Copyright 2007 by Kentrox, Inc. All Rights Reserved. The material discussed in this
More informationAI port High Speed Asynchronous Line Card Installation Guide
AI232 32-port High Speed Asynchronous Line Card Installation Guide Part Number QR-232 Rev 3 2008 by Kentrox, Inc. All rights reserved. Copyright 2008 by Kentrox, Inc. All Rights Reserved. The material
More informationAI180I AIswitch Series 180 Integrated Chassis Installation Guide
AI180I AIswitch Series 180 Integrated Chassis Installation Guide Part Number QR-180I Rev 5 2008 by Kentrox, Inc. All rights reserved. Copyright 2008 by Kentrox, Inc. All Rights Reserved. The material discussed
More informationRemote RMX-3200 Intelligent Site Management Device. Installation Guide
Remote RMX-3200 Intelligent Site Management Device Installation Guide INSTALLATION GUIDE Westell Technologies Part # 030-300637 Rev. A Copyright 2015 by Westell Technologies. All Rights Reserved. Westell,
More informationReplacing the Power Supply
APPENDIX B This appendix includes information on how to replace the power supply for the Cisco AS550XM universal gateway and contains the following sections: Safety Recommendations, page B-1 Required Tools
More informationTRC-190 User s Manual
User s Manual Edition 3.2, May 2017 www.moxa.com/product 2017 Moxa Inc. All rights reserved. User s Manual The software described in this manual is furnished under a license agreement and may be used only
More informationInstalling the Cisco AS5400XM Universal Gateway
CHAPTER 3 Installing the Cisco AS5400XM Universal Gateway This chapter guides you through the installation of the Cisco AS5400XM universal gateway and includes the following sections: Setting Up the Chassis,
More informationTRC-190 User s Manual
First Edition, November 2008 www.moxa.com/product 2008 Moxa Inc. All rights reserved. Reproduction without permission is prohibited. The software described in this manual is furnished under a license agreement
More informationInstalling the Cisco 2524 and Cisco 2525 Routers
CHAPTER 3 Installing the Cisco 2524 and Cisco 2525 Routers This chapter guides you through the installation of the Cisco 2524 and Cisco 2525 routers and includes the following sections: Required Tools
More informationInstallation Note for the Cisco ME 3800X and ME 3600X Switch Power Supply and Fan Modules
Installation Note for the Cisco ME 3800X and ME 3600X Switch Power Supply and Fan Modules This document provides the installation and removal instructions for the AC and DC input power supply and fan modules
More informationJunos WebApp Secure 5.0 Hardware Guide
Junos WebApp Secure 5.0 Hardware Guide Junos WebApp Secure 5.0 Hardware Guide This document contains a specification for the MWS1000 hardware appliance, as well as instructions for installation into a
More informationEnclosure TS-530 User Manual
Enclosure TS-530 User Manual 16525 East Laser Drive Fountain Hills, AZ 85268 TEL 480.837.5200 FAX 480.837.5300 info@embeddedx86.com http://www.embeddedx86.com/ Technologic Systems, Inc. COPYRIGHT 1998-200
More informationQuick Start. This document describes how to install the Juniper Networks PTX5000 Packet Transport
PTX5000 Packet Transport Router Quick Start September 2017 Part Number: 530-066788 Revision 01 This document describes how to install the Juniper Networks PTX5000 Packet Transport Router. Contents Quick
More informationOmnitron Systems Technology, Inc. 1. iconverter. 19-Module Managed Power Chassis User s Manual
Omnitron Systems Technology, Inc. 1 iconverter 19-Module Managed Power Chassis User s Manual 27 Mauchly, #201, Irvine, CA 92618 Phone: (949) 250-6510; Fax: (949) 250-6514 2 Omnitron Systems Technology,
More informationStorage/Control I/O Module
CHAPTER 4 The performs two functions: to connect outside interfaces to the system controller and to house the hard disk drive. It plugs into the back of the VCO/4K system and provides the I/O interfaces
More informationPerle MCR200 Installation Guide
Perle MCR200 Installation Guide P/N 5500322-10 Introduction The Perle MCR200 Chassis is a 2 slot chassis able to accommodate up to 2 Perle Media Converter modules or 1 Media Converter Module and an MCR-MGT
More informationHypercable injecteur HPOE - Industrial IEEE 802.3at Gigabit PoE Injector. User Manual. v.1.0 Jun Mail :
Industrial IEEE 802.3at Gigabit PoE Injector User Manual v.1.0 Jun-2011 FCC Warning This Equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15
More informationM5 and M10 Routers Power Supply and Power Cord Component Replacement Instructions
M5 and M10 Routers Power Supply and Power Cord Component Replacement Instructions Part No. 530-003244-01 Revision 1 27 July 2000 This document describes how to remove and replace the AC and DC power supplies,
More informationInstalling the Cisco Unified Videoconferencing 3545 MCU
CHAPTER 2 Installing the Cisco Unified Videoconferencing 3545 MCU The Cisco Unified Videoconferencing 3545 MCU works together with a Cisco Unified Videoconferencing 3545 EMP Enhanced Media Processor (EMP)
More informationPower Supply and Fan Module Installation
3 CHAPTER This chapter describes how to remove and install a new or replacement power supply or fan module in a Catalyst 3750-E or Catalyst 3560-E switch. See these sections: Installation Overview, page
More informationPower Supply Installation
Power Supply Module Overview, on page Installation Guidelines, on page 4 Installing or Replacing an AC Power Supply, on page 6 Installing a DC Power Supply, on page 7 Finding the Power Supply Module Serial
More informationTCNM-ACBB1 Installation Manual
The TCNM-ACBB1 is a connection box that can be used as an accessory to facilitate system connections for installation and device replacement of several Banner family reading devices. System cabling is
More informationOPTICAL HEADEND PLATFORM OTOHP-CH 3RU CHASSIS OTOHP-PS POWER SUPPLY MODULE OTOHP-BP BLANK PANEL INSTRUCTION MANUAL
OPTICAL HEADEND PLATFORM OTOHP-CH 3RU CHASSIS OTOHP-PS POWER SUPPLY MODULE OTOHP-BP BLANK PANEL INSTRUCTION MANUAL Phone: (209) 586-1022 (800) 545-1022 Fax: (209) 586-1026 OTOHP-CH Rev. X1 E-Mail: salessupport@olsontech.com
More informationM40e and M160 CIP Installation Instructions
Part No. 530-005365-01 Revision 2 23 January 2002 CIP Description This document describes how to remove and replace the Connector Interface Panel (CIP) on a Juniper Networks M40e Internet router or M160
More informationPIX 515/515E. PIX 515/515E Product Overview CHAPTER
CHAPTER 4 PIX 515/515E This chapter describes how to install the PIX 515/515E, and includes the following sections: PIX 515/515E Product Overview Installing a PIX 515/515E PIX 515/515E Feature Licenses
More informationInstallation of the POTS splitter card requires the following steps: Determining the cables you need. Installing the POTS splitter chassis
5910 High Density Lifeline POTS Splitter Installation Instructions Document Number 5910-A2-GZ40-00 May 2005 About the 5910 POTS Splitter The 5910 is a double-density POTS splitter that separates the (Digital
More informationUSER MANUAL MODEL 2017P MODEL 2017P60. RS-232 to 20mA and. RS-232 to 60mA Current Loop Converters
USER MANUAL MODEL 2017P RS-232 to 20mA and MODEL 2017P60 RS-232 to 60mA Current Loop Converters 07M2017P-E Doc# 073051UE Revised 5/7/96 SALES OFFICE (301) 975-1000 TECHNICAL SUPPORT (301) 975-1007 1.0
More informationUser s Guide CPSMC0200-2x0 Dual-Slot PointSystem Chassis
User s Guide CPSMC0200-2x0 Dual-Slot PointSystem Chassis The Transition Networks CPSMC0200-2x0 series dual-slot PointSystem chassis is designed for installation of one or two selectable Transition Networks
More informationInstallation and Configuration Guide
Installation and Configuration Guide Trademark Notices Comtrol, NS-Link, and DeviceMaster are trademarks of Comtrol Corporation. Microsoft and Windows are registered trademarks of Microsoft Corporation.
More informationAn ISO-9001 Certified Company
USER MANUAL MODEL 1002 and 1002S Asynchronous 2-Wire / Coax Short Range Modem An ISO-9001 Certified Company Part #07M1002-C Doc. #050011UC Revised 4/28/98 SALES OFFICE (301) 975-1000 TECHNICAL SUPPORT
More informationThis simple chassis houses one media-converter module and features an external AC power supply and also a terminal block for DC power input.
LMC5103A-R2 1-slot Multipower Desktop Chassis (Module Not Included) This simple chassis houses one media-converter module and features an external AC power supply and also a terminal block for DC power
More informationPerle SMI Media Converter Installation Guide
Perle SMI Media Converter Installation Guide P/N 5500316-14 Overview This guide contains instructions necessary for the installation and operation of the Perle SMI Media Converter. This media converter
More informationS4112-ON Series. Setup Guide
S4112-ON Series Setup Guide Notes, cautions, and warnings NOTE: A NOTE indicates important information that helps you make better use of your product. CAUTION: A CAUTION indicates either potential damage
More informationInstalling Power Modules
This chapter contains the procedures for installing cards and modules into the chassis after the chassis has been installed into a rack. This chapter also describes how to connect cables to RSP, RP, alarm,
More informationWIRESPEED ADSL MODEM (MODEL 2000) User Guide
WIRESPEED ADSL MODEM (MODEL 2000) User Guide Copyright 2001 Westell, Inc. All rights reserved. 030-300187 Rev. A Printed in the United States of America December 2001 CONTENTS 1. PRODUCT DESCRIPTION...
More information9. NTP-C11 Remove and Replace an Ethernet Card, page 1-13 As needed, complete this procedure to remove and replace an ONS CL Ethernet card.
CHAPTER 1 This chapter provides procedures for installing the Cisco ONS 15310-CL shelf, cards, and fiber-optic cable. To view a summary of the tools and equipment required for installation, see the Required
More informationLVN5200A-R2, rev. 1, Hardware Installation Guide
LVN5200A-R2 LVN5250A-R2 LVN5200A-R2, rev. 1, Hardware Installation Guide Customer Support Information Order toll-free in the U.S.: Call 877-877-BBOX (outside U.S. call 724-746-5500) FREE technical support
More informationInstallation and Maintenance
CHAPTER 4 Installation and Maintenance Revised: April 19, 2010, Introduction This chapter explains how to install a SCE 1000 platform in a rack or in a general tabletop or workbench installation. Additionally,
More informationBefore you begin. Unpack & Prepare. Install Hardware. Connect Hardware. Apply Power. Choose Management Method. Install & Use SANtricity Software
Before you begin Installation and Setup Instructions for EF-Series All-Flash Arrays EF550 and EF560 flash arrays DE5600 flash expansion trays Unpack & Prepare Before installing the hardware Confirm that
More informationInstall the Cisco ONS CL
1 CHAPTER This chapter provides procedures for installing the Cisco ONS 15310-CL shelf, cards, and fiber-optic cable. To view a summary of the tools and equipment required for installation, see the Required
More informationBefore you begin. Unpack & Prepare. Install Hardware. Connect Drive Trays. Apply Power. Connect Data Hosts. Choose Management Method
Before you begin Installation and Setup Instructions for E-Series -Drive and 4-Drive Trays E700 and E5600 controller-drive trays DE600 and DE5600 expansion drive trays Unpack & Prepare Install Hardware
More informationUSER MANUAL. MODEL 1225 ParaLink TM Parallel Short Range Modem. SALES OFFICE (301) TECHNICAL SUPPORT (301)
USER MANUAL MODEL 1225 ParaLink TM Parallel Short Range Modem C E R T I F I E D An ISO-9001 Certified Company Part #07M1225-B Doc. #104011UB Revised 9/12/97 SALES OFFICE (301) 975-1000 TECHNICAL SUPPORT
More informationCisco CRS 3-Phase AC Power Distribution Unit Installation Guide 2. Cisco CRS 3-Phase AC Power Distribution Unit 2
Cisco CRS 3-Phase AC Power Distribution Unit Installation Guide Cisco CRS 3-Phase AC Power Distribution Unit Installation Guide 2 Cisco CRS 3-Phase AC Power Distribution Unit 2 Revised: November 18, 2016,
More informationInstallation Notes for the Catalyst 3750-X and 3560-X Switch Power Supply Modules
Installation Notes for the Catalyst 3750-X and 3560-X Switch Power Supply Modules Published: April, 2010 Revised: April, 2013 For information about using the power supply modules with a switch, see the
More informationHardware overview. Package contents MSM710, documentation, power supply, self-adhesive rubber feet.
In MSM710 Controller Quickstart This Quickstart applies to both the MSM710 Access Controller (J9328A) and the MSM710 Mobility Controller (J9325A). This Quickstart introduces the HP ProCurve Networking
More informationMedia Conversion Rack-Mount Chassis AT-MCR12. Installation Guide Rev. A
Media Conversion Rack-Mount Chassis AT-MCR12 Installation Guide 613-000815 Rev. A Copyright 2007 Allied Telesis, Inc. All rights reserved. No part of this publication may be reproduced without prior written
More information1. Carefully unpack the um260 s shipping carton and check the contents for damage.
um260 Installation Manual um260 Installation Chapter 4 um260 MICRO MONITOR INSTALLATION This section of the um260 Micro Monitor Installation Manual describes the requirements and procedures for installing
More informationInstalling the Cisco SFS 3504 Server Switch
CHAPTER 3 This chapter describes how to mount your Cisco SFS 3504 Server Switch on a rack, boot the Cisco SFS 3504 Server Switch, and configure basic services. For advanced configuration information, see
More informationG.SHDSL NTU with Fixed Serial Interfaces
DECEMBER 2006 ME231A ME232A ME233A G.SHDSL NTU with Fixed Serial Interfaces CUSTOMER Order toll-free in the U.S. 24 hours, 7 A.M. Monday to midnight Friday: 877-877-BBOX SUPPORT FREE technical support,
More informationUser Guide CPSMP VAC Power Supply Module: PointSystem CPSMC Accessory CPSMC Accessory. Contents.
User Guide CPSMP-205 110 240 VAC Power Supply Module: PointSystem CPSMC1800-200 Accessory CPSMC1900-100 Accessory Contents Contents...1 Description...1 Cautions and Warnings...2 Definitions...2 Power supply
More informationALTAI C1N SUPER WIFI CPE INSTALLATION GUIDE. Version 1.0 Date: September, Altai Technologies Ltd. All rights reserved
ALTAI C1N SUPER WIFI CPE INSTALLATION GUIDE Version 1.0 Date: September, 2013 Copyright 2007 Altai Technologies Limited ALL RIGHTS RESERVED. Altai Technologies Limited Unit 209, 2/F, East Wing, Building
More information3710 ACM 3750 PDC 3800 RTU. ISOCOM Communications Card Retrofit Instructions
3710 ACM 3750 PDC 3800 RTU ISOCOM Communications Card Retrofit Instructions Danger During normal operation of this device, hazardous voltages are present which can cause severe injury or death. These
More informationMercury Helios ASSEMBLY MANUAL & USER GUIDE
Mercury Helios ASSEMBLY MANUAL & USER GUIDE TABLE OF CONTENTS INTRODUCTION...1 1.1 MINIMUM SYSTEM REQUIREMENTS 1.1.1 Apple Mac Requirements 1.1.2 PC Requirements 1.1.3 Supported PCIe Cards NOTE: Boot Camp
More informationiconverter 2-Module Power Chassis
iconverter 2-Module Power Chassis User Manual 38 Tesla, Irvine, CA 92618 USA Phone: (949) 250-6510; Fax: (949) 250-6514 Page 1 Warning The operating description in this Instruction Manual is for use by
More informationXBR V4 INSTALLATION AND USER GUIDE
XBR V4 INSTALLATION AND USER GUIDE xbr V4 Installation and User Guide Page 1 of 18 Revision History Dash#/Rev Date Author Description 0.1 04/03/2013 Eric Anderson Initial draft 0.2 04/08/2013 Eric Anderson
More information16-Port Chassis Media Converter System Manual
16-Port Chassis Media Converter System Manual 17732-B 16-Port Media Converter (ST Connectors, Shown) INTRODUCTION This system manual describes the ADC 16-Port Media Converter with SC and ST connectors,
More informationInstallation Job Aid for Ethernet Routing Switch 3600 Series
Installation Job Aid for Ethernet Routing Switch 3600 Series Notices NN47213-303 Issue 03.01 November 2017 Notice paragraphs alert you about issues that require your attention. Following are descriptions
More informationPIX 520. PIX 520 Product Overview CHAPTER
CHAPTER 5 PIX 520 This chapter guides you through the installation of the PIX 520, and includes the following sections: PIX 520 Product Overview, page 5-1 Installing the PIX 520, page 5-4 PIX 520 Feature
More information4 10/100/1000T Mini-GBIC with 4 IEEE 802.3at High Power PoE Industrial Wide Temperature Switch. User Manual SISTP LRT
4 10/100/1000T + 2 1000 Mini-GBIC with 4 IEEE 802.3at High Power PoE Industrial Wide Temperature Switch User Manual V1.0 September-2013 FCC Warning This Equipment has been tested and found to comply with
More informationPreparing to Install the VG248
CHAPTER 2 To ensure normal system operation, plan your site configuration and prepare your site before installation. Before installing the VG248, review these sections: Preparing the Installation Site,
More informationCPCI-PS24 24V-Power Supply
24V-Power Supply Hardware Manual to Product I.2301.21 esd electronic system design gmbh Vahrenwalder Str. 207 30165 Hannover Germany http://www.esd.eu Phone: +49 (0) 511 3 72 98-0 Fax: +49 (0) 511 3 72
More informationModular Connectors 75
75 Plug/Jack Compliant to Enhanced Category 5 standards Connector type Size Series Name Page plug connectors compliant to enhanced category 5 standards 8 TM21P 77 jack connectors for high-speed LAN transmission
More informationSIP 3CX Based Private Branch Exchange
SmartNode Branch exchange Series SIP 3CX Based Private Branch Exchange Quick Start Guide Important This is a Class B device and is intended for use in a light industrial or residential environment. It
More informationFLEX Ex Spring Clamp Terminal Base
Installation Instructions FLEX Ex Spring Clamp Terminal Base (Cat. No. 1797-TB3S) 1 10 11 4 Only remove this cover plug if connecting another terminal base unit. 3 5 6 12 2 7 8 9 41253 Component Identification
More informationInstalling and Removing SDRAM and DRAM
CHAPTER 4 This chapter explains how to remove and replace the main memory modules on the network processing engine or network services engine. For the location of the memory module you are replacing, find
More informationG.SHDSL NTU DECEMBER 2006 LB510A
DECEMBER 2006 LB510A G.SHDSL NTU CUSTOMER Order toll-free in the U.S. 24 hours, 7 A.M. Monday to midnight Friday: 877-877-BBOX SUPPORT FREE technical support, 24 hours a day, 7 days a week: Call 724-746-5500
More informationTN-5308 Quick Installation Guide
TN-5308 Quick Installation Guide Moxa ToughNet Switch Edition 6.0, February 2017 Technical Support Contact Information www.moxa.com/support Moxa Americas: Toll-free: 1-888-669-2872 Tel: 1-714-528-6777
More informationhp uninterruptible power system r12000 xr models installation instructions
hp uninterruptible power system r000 xr models installation instructions Overview These instructions show how to install an uninterruptible power system (UPS). For detailed information about the UPS, refer
More informationRelease Notes. Electrostatic Discharge and Grounding Guide for Cisco NCS 2000 Series. Prerequisites. Preparing Your Location
First Published: 2017-01-31 Text Part Number: Electrostatic Discharge and Grounding Guide for Cisco NCS 2000 Series Prerequisites This document uses illustrations to explain the workflow that we recommend
More informationInfinity 1U 19 Converter Shelf Models: J L217 - Individual +24V Inputs Bulk -48V Output L218 - Individual -48V Input Bulk+24V Output
GE Critical Power Quick Start Guide Infinity 1U 19 Converter Shelf Models: J5964803 L217 - Individual +24V Inputs Bulk -48V Output L218 - Individual -48V Input Bulk+24V Output Edge Controller This shelf
More informationConnecting Power and Ground
This chapter explains how to connect the power and ground for NCS 2006 shelf. The sections are: Power and Ground Description, page 1 NTP-L12 Installing Power and Ground to the NCS 2006 Shelf, page 2 Power
More informationInnoMedia Business VoIP ATA Models
InnoMedia Business VoIP ATA Models MTA8328-4, MTA8328-8, MTA8328-24 Quick Installation Guide Important Safety Instructions Protective Earthing Protective earthing is used as a safeguard. This equipment
More informationQFX10008 Switch Quick Start Guide
QFX10008 Switch Quick Start Guide January 2014 Part Number: 530-068237 Revision 01 This document describes how to install the Juniper Networks QFX10008 Switch Chassis. Contents Quick Start Description...............................................
More informationLantech. IPES /100TX with 4 PoE Injectors 24~48VDC Industrial Switch. User Manual
Lantech IPES-0008-4 8 10/100TX with 4 PoE Injectors 24~48VDC Industrial Switch User Manual V1.00 Jun 2010 FCC Warning This Equipment has been tested and found to comply with the limits for a Class-A digital
More informationInstalling the Cisco MDS 9020 Fabric Switch
CHAPTER 2 This chapter describes how to install the Cisco MDS 9020 Fabric Switch and its components, and it includes the following information: Pre-Installation, page 2-2 Installing the Switch in a Cabinet
More informationFollow the procedure below for unpacking the carton in which the device is shipped. DW-GTW-AC-E1060 Four anti-slide bumpers for desktop installation
1 Introduction This document provides a hardware description of the DW-GTW-AC-E1060 (hereafter referred to as device) and step-by-step procedures for mounting and cabling the device. The device supports
More informationFujitsu Stylistic ST4000 Series TABLET DOCK USER S GUIDE
Fujitsu Stylistic ST4000 Series TABLET DOCK USER S GUIDE DECLARATION OF CONFORMITY according to FCC Part 15 Responsible Party Name: Fujitsu PC Corporation Address: 5200 Patrick Henry Drive Santa Clara,
More informationMC 11 EB-2 Power supply cabinet with external bus, AC version
MC 11 EB-2 Power supply cabinet with external bus, AC version USER/MAINTENANCE MANUAL 1 SLOT 0 SLOT 1 SLOT 2 SLOT 3 SLOT 4 SLOT 5 SLOT 6 SLOT 7 SLOT 8 SLOT 9 SLOT 10 SLOT 11 EB-2 (a) MC11 (b) (c) Figures
More informationXBR V3 INSTALLATION AND USER GUIDE Rev 03. xbr V3 Installation and User Guide Page 1 of 14. (preliminary)
XBR V3 INSTALLATION AND USER GUIDE xbr V3 Installation and User Guide Page 1 of 14 Revision History Rev Date Author Description 01 07/03/2012 Eric Anderson Initial release 02 09/25/2012 Eric Anderson Clarification
More informationOWC Mercury Helios 2 ASSEMBLY MANUAL & USER GUIDE
OWC Mercury Helios 2 ASSEMBLY MANUAL & USER GUIDE TABLE OF CONTENTS 1. INTRODUCTION...1 1.1 MINIMUM SYSTEM REQUIREMENTS 1.1.1 Apple Mac Requirements 1.1.2 PC Requirements 1.1.3 Supported PCIe Cards 1.2
More informationDell Networking S4810 Open Networking (ON) Getting Started Guide
Dell Networking S4810 Open Networking (ON) Getting Started Guide Regulatory Model: S4810 Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make better use of your
More informationINSTALLATION INSTRUCTIONS FOR THE BV10-100/1000
INSTALLATION INSTRUCTIONS FOR THE BV10-100/1000 This document describes the basic steps for installing your BV10-100 or BV10-1000. For detailed information about the BV10-100/1000, see the Ethernet Performance
More informationDATA DOUBLER. Apple Mac mini (2009)
DATA DOUBLER Apple Mac mini (2009) TABLE OF CONTENTS Introduction... 1 1.1 Hardware Compatibility 1.1.1 Host Computer Compatibility 1.1.2 Drive Compatibility 1.2 Package Contents 1.3 About This Manual
More informationA TCP/IP network CAT 5 cable If the network is faster than 10baseT a switching hub will be needed Static IP address
Requirements A TCP/IP network CAT 5 cable If the network is faster than 10baseT a switching hub will be needed Static IP address Power Up A Reader with an Ethernet adaptor installed and the network cable
More informationH3C S12500 Routing Switch Series
H3C S12500 Routing Switch Series Quick Installation Guide Hangzhou H3C Technologies Co., Ltd. http://www.h3c.com Document version: APW201-20131030 Copyright 2013, Hangzhou H3C Technologies Co., Ltd. and
More informationService Managed Gateway TM. Installing and Configuring the GW8600 SMG
Service Managed Gateway TM Installing and Configuring the GW8600 SMG Issue 1.1 Date 14 August 2007 Table of Contents 1 About this document...3 1.1 Scope...3 1.2 Readership...3 1.3 More information...3
More informationObtaining Documentation and Submitting a Service Request, page xvii Safety Warnings, page xvii Safety Guidelines, page xx
Preface Obtaining Documentation and Submitting a Service Request, page xvii Safety s, page xvii Safety Guidelines, page xx Obtaining Documentation and Submitting a Service Request For information on obtaining
More informationHP UPS R/T3000 G2. Overview. Precautions. Kit contents. Installation Instructions
HP UPS R/T3000 G2 Installation Instructions Overview The HP UPS R/T3000 G2 features a 2U rack-mount with convertible tower design and offers power protection for loads up to a maximum of 3300 VA/3000 W
More informationSite Preparation CHAPTER
CHAPTER 3 Site Preparation This chapter describes the steps to take and the considerations you should keep in mind prior to installing the modules in an open rack. It also contains information that applies
More informationLNP series. 5-port Industrial PoE+ Unmanaged Ethernet Switches 4*10/100Tx (30W/Port) + 1*10/100Tx, 12~36VDC Input.
LNP-0500-24 series 5-port Industrial PoE+ Unmanaged Ethernet Switches 4*10/100Tx (30W/Port) + 1*10/100Tx, 12~36VDC Input User Manual FCC Warning This Equipment has been tested and found to comply with
More informationTraceTek Leak Detection Master Module Installation Instructions TOOLS REQUIRED STORAGE
TTDM-128 TraceTek Leak Detection Master Module Installation Instructions TRACETEK APPROVALS AND CERTIFICATIONS TYPE NM General Signaling Equipment 76LJ GENERAL INFORMATION Please read these instructions
More information9109 FXS Analog Voice Application Module (APM) Installation Instructions. Product Documentation on the World Wide Web
TM 9109 FXS Analog Voice Application Module (APM) Installation Instructions Document Number 9109-A2-GN12-40 May 1999 Product Documentation on the World Wide Web We provide complete product documentation
More informationLeased-Line Extenders over IP
SmartNode 2290 Series Leased-Line Extenders over IP Quick Start Guide Important This is a Class A device and is intended for use in a light industrial environment. It is not intended nor approved for use
More informationSySTIUM TECHNOLOGIES. Assembly Guide. Model 133i
Assembly Guide Model 133i Radio Frequency Interference Notice (USA) This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules,
More informationInstallation Job Aid for VSP 4850GTS
Installation Job Aid for VSP 4850GTS Notices Release 6.1.0.0 NN46251-308 Issue 02.01 November 2017 Notice paragraphs alert you about issues that require your attention. The following paragraphs describe
More informationPanelView Plus/VersaView CE Terminals and Display Modules
Installation Instructions PanelView Plus/VersaView CE Terminals and Display Modules (Catalog Numbers 2711P-xxxxxx, 6182H-xxxxxx) English Inside: Overview...2 For More Information...2 Modular Components...3
More information