Read the whole of this document before unpacking your Izon equipment or proceeding to the steps below.

Size: px
Start display at page:

Download "Read the whole of this document before unpacking your Izon equipment or proceeding to the steps below."

Transcription

1 Getting Started Read the whole of this document before unpacking your Izon equipment or proceeding to the steps below. 1. Take the USB drive out of your training kit and put the rest of the contents in a refrigerator. 2. Read the qnano User Manual which can be found as PDF files on the USB drive. The User Manual has detailed instrument descriptions and installation information. 3. Install the Izon Control Suite Software (CSS): a. Insert the Izon USB drive into your computer. b. An auto run prompt will ask you to run Install.exe. 4. Once Izon Control Suite software and instrument are both successfully installed, complete reading the User Manual and proceed to undertake the training course described in the Izon s TRPS Training Module PDF document on the USB drive. Important: Do not attempt to operate the equipment until successfully completing the Izon Training Programme. Additional support material is available on the support portal (KBase), sign up here: Website URL: If you have any questions that are not answered on the KBase, please contact our Support staff via KBase or directly by or skype: support@izon.com Skype: IzonSupport QN1-IQ-013(F)

2 Important Read Before Operating Izon Instrumentation Follow all directions in this document and complete the Izon Training Module before attempting to operate the instrument, they contain important safety and operational information. Use of this instrument in a manner not specified by the instructions in this guide and the training module may impair the safety protection provided. Do not operate the instrument outside its rated supply voltages or environmental range Failure to read these instructions and the training module and use the instrument in the manner specified may result in impaired performance and damage to the equipment. The following symbols are used on the instrument and in this manual:- Earth (ground) terminal. Direct Current (DC) Voltage polarity of Jack. USB Connection Caution risk of danger or impaired operation, if instructions not followed Important please read below for installation instructions and an explanation on connecting and operation of the instrument.

3 Izon Instrument Components and Installation qnano qmicro qviro-x See the qnano User Manual.pdf located in the Training Module folder on the USB drive from the training kit. See the qmicro User Manual.pdf in the Guides folder on the USB drive from the training kit. See the qviro-x Getting Started Guide in the Guides folder on the USB drive from the training kit. Powering Your Instrument IMPORTANT Plug into Earth Grounded Protected Outlets ONLY. Make sure power supply box is positioned off benches and away from fluids. To prevent heat build-up, do not cover the power-supply box. Position unit so it can easily and quickly be disconnected from mains power. Mains Operating Voltage This instrument has a universal input range and will operate from a nominal 115 V or 230 V mains supply without adjustment. Check that the local supply meets the AC Input requirement given in the Specification. Izon Instruments are only to be operated with Izon supplied leads and power supply. Failure to use the correct power supply may result in invalid operation. Do not place the power supply in a position where it can come into contact with spills or moisture. Make sure the power supply is placed away and to the rear of the instrument to avoid spills during filling the fluid cell. Computer Equipment Set-up Devices that can be connected to the equipment should be compliant with a relevant safety standard such as IEC for IT equipment or IEC for laboratory equipment and should provide double or reinforced insulation from hazardous voltage sources.

4 Do not place any computer for connecting to the Izon instrument in a position where it can come into contact with spills or moisture. Make sure Izon supplied USB cable is used. General Operating Precautions For indoor use only, to be used within the rated condition in system specifications Take care not to spill fluids on electrical parts during operation Repair and Servicing of your Izon Instrument There are no user serviceable parts. Return equipment to Izon for service. All replacement parts, cables, mains-leads, power-supply, nanopores, fluid cells must be obtained via Izon Science Ltd. Cleaning of your Izon Instrument Care and cleaning of your instrument is important for correct operation. Failure to follow the proper care instructions may result in impaired operation. Please refer to the following product documents for cleaning and care instructions; qviro-x & qnano 21 CFR part 11 installs qnano qmicro Refer to the SOP for Performing Installation Qualification Protocol for a qnano manual, section 10. Follow the instructions in Section 5 of the qnano User Manual Refer to the qmicro User Manual Take care with cleaning not to spill excess fluid on other equipment Consumables Ordering For ordering of nanopores, calibration particles, and other consumables, please see our online store at store.izon.com.

5 System Specification Item Specification Comment Environment Indoor use at altitudes up to 2000 m, Pollution Degree 2 20% to 80% RH. Operating Temperature 5 C to 25 C RMS noise performance i Typical < 10 pa For +/- 200 na range NP200 Data sampling rate 50,000 samples per second USB standard connector Max input voltage USB 2.0 Mini-B 5.00 ± 0.25 V Cable must be to relevant safety standard such as IEC for IT equipment or IEC for laboratory equipment and should provide double or reinforced insulation from hazardous voltage sources Electrical Power ii Voltage, current Power consumption 12 V (DC ), 130 ma 1.5 W At input jack on instrument PSU Output DC Input AC Output current max Output power max 90 to 264 Vac 50/60 Hz ac 12 V nom 3.75 A 45 W iii Use only Izon supplied TRG45A120-21E11 Nanopore holding stage extension range Min 41mm Max 61mm Measured across the outside of opposing holding arms. Electrical safety IEC/EN EMC IEC/EN i Under electrical interference noise may increase but will return to normal operation on end of interference. Position equipment away from electrical switching gear and interfering equipment or noise may increase under sample running conditions. ii For no equipment plugged into the Izon auxiliary interface. iii PSU module rating. Izon Instruments running normally are approx. less than 1.6W

User's Guide. Phase Sequence and Motor Rotation Tester Model

User's Guide. Phase Sequence and Motor Rotation Tester Model User's Guide Phase Sequence and Motor Rotation Tester Model 480403 Introduction Congratulations on your purchase of the Extech Model 408403 Motor and Phase Rotation Indicator. This handheld instrument

More information

Models 2601B, 2602B, and 2604B System SourceMeter Instruments Quick Start Guide

Models 2601B, 2602B, and 2604B System SourceMeter Instruments Quick Start Guide Models 2601B, 2602B, and 2604B System SourceMeter Instruments Quick Start Guide Safety precautions Observe the following safety precautions before using this product and any associated instrumentation.

More information

Mini Digital Multimeter

Mini Digital Multimeter User Manual Mini Digital Multimeter Model MN15A Additional User Manual Translations available at www.extech.com Introduction Congratulations on your purchase of the Extech MN15A MultiMeter. The MN15A offers

More information

User Guide True RMS Multimeter Extech EX205T

User Guide True RMS Multimeter Extech EX205T User Guide Extech EX205T True RMS Digital Multimeter Extech EX210T True RMS Digital Multimeter IR True RMS Multimeter Extech EX205T Introduction Thank you for selecting the Extech EX205T True RMS Auto-ranging

More information

Mini Digital Multimeter

Mini Digital Multimeter User's Guide Mini Digital Multimeter Model MN15 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com Back to the Extech MN15/MN16 Series

More information

USER MANUAL. Mini Multimeter with Non-Contact Voltage Detector (NCV) Model EX310

USER MANUAL. Mini Multimeter with Non-Contact Voltage Detector (NCV) Model EX310 USER MANUAL Mini Multimeter with Non-Contact Voltage Detector (NCV) Model EX310 Introduction Congratulations on your purchase of the Extech EX310 MultiMeter. The EX310 offers AC/DC Voltage, AC/DC Current,

More information

Mini Digital Multimeter

Mini Digital Multimeter User's Guide Mini Digital Multimeter Model MN15 Introduction Congratulations on your purchase of the Extech MN15 MultiMeter. The MN15 offers AC/DC Voltage, AC/DC Current, Resistance, Diode, and Continuity

More information

Mini Digital Multimeter Model MN15. User's Guide

Mini Digital Multimeter Model MN15. User's Guide Mini Digital Multimeter Model MN15 User's Guide Introduction Congratulations on your purchase of the Extech MN15 MultiMeter. The MN15 offers AC/DC Voltage, AC/DC Current, Resistance, Diode, and Continuity

More information

Autoranging Mini Multimeter

Autoranging Mini Multimeter User Manual Autoranging Mini Multimeter Model MN16A Additional User Manual Translations available at www.extech.com Introduction Congratulations on your purchase of the Extech MN16A Autoranging Multimeter.

More information

BENCH-TOP DIGITAL MULTIMETER INSTRUCTION MANUAL

BENCH-TOP DIGITAL MULTIMETER INSTRUCTION MANUAL BENCH-TOP DIGITAL MULTIMETER INSTRUCTION MANUAL SK-4033 / SK-4035 Thank you for purchasing KAISE MODEL SK-4033/4035 BENCH-TOP DIGITAL MULTIMETERS. To obtain the maximum performance of this instrument,

More information

User's Guide. Digital Multimeter. Model MN42

User's Guide. Digital Multimeter. Model MN42 User's Guide Digital Multimeter Model MN42 Introduction Congratulations on your purchase of the Extech MN42 MultiMeter. The MN42 offers AC/DC Voltage, DC Current, and Resistance testing. Proper use and

More information

User Manual. 400Amp AC Clamp Meter + NCV. Model MA430. Additional User Manual Translations available at

User Manual. 400Amp AC Clamp Meter + NCV. Model MA430. Additional User Manual Translations available at User Manual 400Amp AC Clamp Meter + NCV Model MA430 Additional User Manual Translations available at www.extech.com Introduction Congratulations on your purchase of this Extech MA430 Clamp Meter. This

More information

9040/9040UK. Users Manual. Phase Rotation Indicator

9040/9040UK. Users Manual. Phase Rotation Indicator 9040/9040UK Phase Rotation Indicator Users Manual PN 2438546 April 2005 2005 Fluke Corporation. All rights reserved. Printed in China All product names are trademarks of their respective companies. LIMITED

More information

EARTH RESISTANCE & RESISTIVITY TESTER

EARTH RESISTANCE & RESISTIVITY TESTER 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com BST-ET103 EARTH RESISTANCE & RESISTIVITY TESTER INSTRUCTION MANUAL INDEX 1. INTRODUCTION...

More information

Model 2380 Rack-Mount Kit

Model 2380 Rack-Mount Kit Keithley Instruments 28775 Aurora Road Cleveland, Ohio 44139 1-800-935-5595 http://www.tek.com/keithley Model 2380 Rack-Mount Kit Installation Instructions Introduction The Model 2380 Fixed Rack-Mount

More information

User s Guide. 600A True RMS AC/DC Clamp Meter. Model 38389

User s Guide. 600A True RMS AC/DC Clamp Meter. Model 38389 User s Guide 600A True RMS AC/DC Clamp Meter Model 38389 Safety International Safety Symbols This symbol, adjacent to another symbol or terminal, indicates the user must refer to the manual for further

More information

Model A Mini AC/DC Clamp Meter. User's Guide

Model A Mini AC/DC Clamp Meter. User's Guide Model 380950 80A Mini AC/DC Clamp Meter User's Guide Introduction Congratulations on your purchase of the Extech 80A Mini AC/DC Clamp Meter. The Model 380950 measures AC/DC Current, AC/DC Voltage, Resistance,

More information

Operating Instructions

Operating Instructions Bracken Hill South West Industrial Estate Peterlee Co Durham SR8 2SW ENGLAND Tel: +44(0)191 5863511 www.seaward.co.uk sales@seaward.co.uk service@seaward.co.uk Part Number 344A550 Revision 1 2006 Seaward

More information

Operating Instructions

Operating Instructions PRIMETEST 100 PRIMETEST 100 Bracken Hill South West Industrial Estate Peterlee Co Durham SR8 2SW ENGLAND Tel: +44(0)191 5863511 www.seaward.co.uk sales@seaward.co.uk service@seaward.co.uk Part Number

More information

OPERATING INSTRUCTION. Pen-Type Digital Multimeter

OPERATING INSTRUCTION. Pen-Type Digital Multimeter OPERATING INSTRUCTION Pen-Type Digital Multimeter International Safety Symbols This symbol, adjacent to another symbol or terminal, indicates the user must refer to the manual for further information.

More information

HV-CS kv Edge Mount Triaxial Jack

HV-CS kv Edge Mount Triaxial Jack Keithley Instruments 28775 Aurora Road Cleveland, Ohio 44139 1-800-935-5595 http://www.tek.com/keithley HV-CS-1589 3 kv Edge Mount Triaxial Jack Installation Information Description The Keithley Instruments

More information

NI PXI-1042 Series Power Supply Shuttle

NI PXI-1042 Series Power Supply Shuttle USER GUIDE NI PXI-1042 Series Power Supply Shuttle Introduction Unpacking The NI PXI-1042 Series power supply shuttle is a replacement part for the NI PXI-1042 Series chassis. To minimize downtime caused

More information

Digital Clamp Meter User Manual

Digital Clamp Meter User Manual Compact AC, AC/DC Digital Clamp Meter User Manual Please read this manual before switching the unit on. Important safety information inside. Contents 1.Safety... 3 2.Safety Notes... 3 3.Warnings... 3 4.Cautions...

More information

CM-220 True RMS AC CLAMP METER INSTRUCTION MANUAL

CM-220 True RMS AC CLAMP METER INSTRUCTION MANUAL CM-220 True RMS AC CLAMP METER INSTRUCTION MANUAL Safety International Safety Symbols This symbol, adjacent to another symbol or terminal, indicates the user must refer to the manual for further information.

More information

Owner's Manual. True RMS Multimeter. Model No Safety Operation Maintenance Español

Owner's Manual. True RMS Multimeter. Model No Safety Operation Maintenance Español Owner's Manual True RMS Multimeter Model No. 82023 CAUTION: Read, understand and follow Safety Rules and Operating Instructions in this manual before using this product. Safety Operation Maintenance Español

More information

Model 4200-CVU-PWR. Parts Package. Introduction. PA-977 Rev. C / September 2016 *PPA-977C* 1

Model 4200-CVU-PWR. Parts Package. Introduction. PA-977 Rev. C / September 2016 *PPA-977C* 1 Keithley Instruments 28775 Aurora Road Cleveland, Ohio 44139 1-800-935-5595 http://www.tek.com/keithley Model 4200-CVU-PWR Parts Package Introduction The Model 4200-CVU-PWR C-V Power Package for both the

More information

OPERATING INSTRUCTION

OPERATING INSTRUCTION OPERATING INSTRUCTION AUTORANGING MULTIMETER MAX Ω F C 10A MAX every 15 min. COM V SAFETY INFORMATION The following safety information must be observed to insure maximum personal safety during the operation

More information

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODELS:

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODELS: IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODELS: 61-773 61-775 The Service Information provides the following information: Precautions and safety information Specifications Performance test procedure Calibration

More information

NI PXIe-1062Q Power Supply Shuttle

NI PXIe-1062Q Power Supply Shuttle USER GUIDE NI PXIe-1062Q Power Supply Shuttle The NI PXIe-1062Q power supply shuttle is a replacement part for the NI PXIe-1062Q chassis. Caution This power supply is not compatible with any other National

More information

User's Guide. MiniTec TM Series Model MN25 MultiMeter

User's Guide. MiniTec TM Series Model MN25 MultiMeter User's Guide MiniTec TM Series Model MN25 MultiMeter Warranty EXTECH INSTRUMENTS CORPORATION warrants this instrument to be free of defects in parts and workmanship for one year from date of shipment (a

More information

APT20. User Manual.

APT20. User Manual. APT20 User Manual www.audac.eu 2 Index Introduction 5 Precautions 6 Safety requirements 6 Caution servicing 6 EC Declaration of conformity 7 Waste of Electrical and Electronic Equipment (WEEE) 7 Caution

More information

User's Guide. 800 Amp Clamp Meters. EX710 AC Clamp meter EX720 True RMS AC Clamp meter EX730 AC/DC True RMS Clamp meter

User's Guide. 800 Amp Clamp Meters. EX710 AC Clamp meter EX720 True RMS AC Clamp meter EX730 AC/DC True RMS Clamp meter User's Guide 800 Amp Clamp Meters EX710 AC Clamp meter EX720 True RMS AC Clamp meter EX730 AC/DC True RMS Clamp meter Introduction Congratulations on your purchase of the EX710, EX720, or EX730 Clamp DMM.

More information

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL:

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL: IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL: 61-796 The Service Information provides the following information: Precautions and safety information Specifications Performance test procedure Calibration

More information

PAT-Cal 2 TECHNICAL MANUAL

PAT-Cal 2 TECHNICAL MANUAL Portable Appliance Tester Calibrator PAT-Cal 2 TECHNICAL MANUAL 1 Time Electronics Limited Botany Industrial Estate, Tonbridge, Kent, TN9 1RH. Tel: +44(0)1732 355993 Fax: +44(0)1732 770312 Email: info@timeelectronics.co.uk

More information

S-14 S-14. Compact Digital Multimeter. Compact Digital Multimeter

S-14 S-14. Compact Digital Multimeter. Compact Digital Multimeter S-14 Compact Digital Multimeter S-14 Compact Digital Multimeter SAFETY INFORMATION The following safety information must be observed to insure maximum personal safety during the operation at this meter

More information

ETHOS Auto Ranging Digital Multimeter

ETHOS Auto Ranging Digital Multimeter ETHOS 5020 Auto Ranging Digital Multimeter 1 1. SAFETY INFORMATION SAFETY SYMBOLS Warning! Dangerous Voltage (Risk of electric shock). Caution! Refer to the user s manual before using this Meter. Double

More information

Model R5010. TRMS Digital Multimeter. Instruction Manual

Model R5010. TRMS Digital Multimeter. Instruction Manual INSTRUMENTS Model R5010 TRMS Digital Multimeter Instruction Manual Table of Contents Safety...3-4 IEC1010 Overvoltage Installation Category... 3 Warnings... 4 Features... 5 Specifications...5-8 Instrument

More information

CONTENTS. 1- INTRODUCTION 1.1 Introduction 1.2 General Applications and Benefits 1.3 Identification 2- HARDWARE

CONTENTS. 1- INTRODUCTION 1.1 Introduction 1.2 General Applications and Benefits 1.3 Identification 2- HARDWARE 1 CONTENTS 1- INTRODUCTION 1.1 Introduction 1.2 General Applications and Benefits 1.3 Identification 2- HARDWARE 3- SOFTWARE DESCRIPTION 3.1 Introduction 3.2 TVS-1000 software 3.3 Software Installation

More information

Laboratory Switch Mode Power Supply Series. Instruction Manual

Laboratory Switch Mode Power Supply Series. Instruction Manual Laboratory Switch Mode Power Supply Series Instruction Manual Model 72-8340 1.0 ~ 60VDC 0 ~ 1.6A 72-8345 1.0 ~ 36VDC 0 ~ 3A 72-8350 1.0 ~ 20VDC 0 ~ 5A Copyright 2008, all rights reserved Tenma Test Equipment

More information

RTD. Process Calibrator. User s MANUAL. PDF created with pdffactory Pro trial version

RTD. Process Calibrator. User s MANUAL. PDF created with pdffactory Pro trial version RTD Process Calibrator User s MANUAL Safety Information RTD Process Calibrator User s Manual To avoid possible electric shock or personal injury: Never apply more than 30V between any two jacks, or between

More information

NI PXI-1042 POWER SUPPLY SHUTTLE USER GUIDE

NI PXI-1042 POWER SUPPLY SHUTTLE USER GUIDE NI PXI-1042 POWER SUPPLY SHUTTLE USER GUIDE Introduction Unpacking The NI PXI-1042 power supply shuttle is a replacement part for the PXI-1042 chassis. To minimize downtime caused by a power-supply failure,

More information

INSTRUCTION MANUAL. Model True RMS AC/DC 30A Mini Clamp-on Meter. Introduction. True RMS AC Current and Voltage

INSTRUCTION MANUAL. Model True RMS AC/DC 30A Mini Clamp-on Meter. Introduction. True RMS AC Current and Voltage INSTRUCTION MANUAL Model 380942 True RMS AC/DC 30A Mini Clamp-on Meter True RMS AC Current and Voltage Measure low current with high resolution to 0.1mA AC and 1mA DC Auto Power Off One touch DCA zero

More information

MODEL 805 USER MANUAL

MODEL 805 USER MANUAL MODEL 805 USER MANUAL All Rights Reserved Page 1 of 12 UNPACKING & INSPECTION Save all packing materials they are required for returns and warranty service. Inspect the 805 and packing materials for any

More information

Model 2460-KIT. Screw Terminal Connector Kit. Description / September 2014 *P * 1

Model 2460-KIT. Screw Terminal Connector Kit. Description / September 2014 *P * 1 Keithley Instruments 28775 Aurora Road Cleveland, Ohio 44139 1-800-935-5595 http://www.keithley.com Model 2460-KIT Screw Terminal Connector Kit Description The Model 2460-KIT Screw Terminal Connector Kit

More information

Model 8010 High Power Device Test Fixture Interconnection Reference Guide

Model 8010 High Power Device Test Fixture Interconnection Reference Guide Model 8010 High Power Device Test Fixture Interconnection Reference Guide Safety precautions Observe the following safety precautions before using this product and any associated instrumentation. Although

More information

DM-918 OPERATIONS MANUAL AUTORANGING MULTIMETER

DM-918 OPERATIONS MANUAL AUTORANGING MULTIMETER DM-918 OPERATIONS MANUAL AUTORANGING MULTIMETER SAFETY INFORMATION The following safety information must be observed to ensure maximum personal safety during the operation of this meter: This meter is

More information

Manual Supplement. This supplement contains information necessary to ensure the accuracy of the above manual.

Manual Supplement. This supplement contains information necessary to ensure the accuracy of the above manual. Manual Supplement Manual Title: 601PRO XL Operators Supplement Issue: 5 Part Number: 2234222 Issue Date: 9/18 Print Date: April 2005 Page Count: 5 Revision/Date: This supplement contains information necessary

More information

SOUND LEVEL METER DVM1351 INSTRUCTION MANUAL HANDLEIDING MANUEL D UTILISATEUR DVM1351 SOUND LEVEL METER 1

SOUND LEVEL METER DVM1351 INSTRUCTION MANUAL HANDLEIDING MANUEL D UTILISATEUR DVM1351 SOUND LEVEL METER 1 SOUND LEVEL METER DVM1351 INSTRUCTION MANUAL HANDLEIDING MANUEL D UTILISATEUR DVM1351 SOUND LEVEL METER 1 SAFETY INFORMATION l Read the following safety information carefully before attempting to operate

More information

80W (16V/5A) Power Supply with USB Output. User Manual

80W (16V/5A) Power Supply with USB Output. User Manual Test Equipment Depot - 800.517.8431-99 Washington Street Melrose, MA 02176 TestEquipmentDepot.com 1325 80W (16V/5A) Power Supply with USB Output User Manual 1325 Volt. C.V. Amp. C.C. V OUTPUT ON/OFF A

More information

Autoranging True RMS Multimeter User Manual

Autoranging True RMS Multimeter User Manual Autoranging True RMS Multimeter User Manual Please read this manual before switching the unit on. Important safety information inside. Contents Page 1. Safety Information... 4 2. Safety Symbols... 5 3.

More information

Model: Pro93 TRUE RMS LEAKAGE CURRENT TESTER

Model: Pro93 TRUE RMS LEAKAGE CURRENT TESTER Model: Pro93 TRUE RMS LEAKAGE CURRENT TESTER CONTENTS TITLE PAGE I. Safety Information.......1 Environmental Conditions... 1 Explanation of Symbols..... 1 II. Specification..... 2 General Specification...

More information

OWNER S MANUAL 9908-TE. HIGH PRECISION AUTO-RANGING DC/True RMS AC BENCH-TOP DIGITAL MULTIMETER

OWNER S MANUAL 9908-TE. HIGH PRECISION AUTO-RANGING DC/True RMS AC BENCH-TOP DIGITAL MULTIMETER OWNER S MANUAL 9908-TE HIGH PRECISION AUTO-RANGING DC/True RMS AC BENCH-TOP DIGITAL MULTIMETER IMPORTANT! Read and understand this manual before using the instrument. Failure to understand and comply with

More information

AutoRanging Digital MultiMeter

AutoRanging Digital MultiMeter Owner's Manual AutoRanging Digital MultiMeter Model No. 82175 CAUTION: Read, understand and follow Safety Rules and Operating Instructions in this manual before using this product. Safety Operation Maintenance

More information

Mid-span 802.3af PoE Injector. Installation Guide KPOE-100

Mid-span 802.3af PoE Injector. Installation Guide KPOE-100 Mid-span 802.3af PoE Injector Installation Guide KPOE-100 Doc. 070521 1 (C) 2005 KTI Networks Inc. All rights reserved. No part of this documentation may be reproduced in any form or by any means or used

More information

This 4200-RM Rack Mount Kit is for installation in 4200-CAB series cabinets only.

This 4200-RM Rack Mount Kit is for installation in 4200-CAB series cabinets only. Keithley Instruments, Inc. 28775 Aurora Road Cleveland, Ohio 44139 (440) 248-0400 Fax: (440) 248-6168 www.keithley.com Model 4200-RM Rack Mount Kit Packing List Introduction NOTE This 4200-RM Rack Mount

More information

±15 V Current-Limited Power Supply

±15 V Current-Limited Power Supply USER S GUIDE ±15 V Current-Limited Power Supply Model 0901 Newport Corporation 3635 Peterson Way Santa Clara, CA 95054 www.newport.com/newfocus EU Declaration of Conformity We declare that the accompanying

More information

USB-2001-TC. USB-based Thermocouple Input. User's Guide

USB-2001-TC. USB-based Thermocouple Input. User's Guide USB-2001-TC USB-based Thermocouple Input User's Guide Document Revision 6A November 2014 Copyright 2014 Trademark and Copyright Information Measurement Computing Corporation, InstaCal, Universal Library,

More information

Allworx 24x Service and Troubleshooting Guide

Allworx 24x Service and Troubleshooting Guide Allworx 24x Service and Troubleshooting Guide -PAGE INTENTIALLY LEFT BLANK- Table of Contents 1 Safety Instructions...1 1.1 Electrical...1 1.2 Electrostatic Discharge...1 2 Chassis Views...2 3 Exterior

More information

Quick Start Guide and Health and Safety Information

Quick Start Guide and Health and Safety Information D397-10-880 Issue F Original Quick Start Guide and Health and Safety Information Turbo Instrument Controller (TIC) Description TIC Instrument Controller 3 Gauge TIC Instrument Controller 6 Gauge TIC Instrument

More information

User s Guide. 600A AC Clamp Meter. Model 38387

User s Guide. 600A AC Clamp Meter. Model 38387 User s Guide 600A AC Clamp Meter Model 38387 Safety International Safety Symbols This symbol, adjacent to another symbol or terminal, indicates the user must refer to the manual for further information.

More information

Agilent U2722A USB Modular Source Measure Unit. Data Sheet

Agilent U2722A USB Modular Source Measure Unit. Data Sheet Agilent U2722A USB Modular Source Measure Unit Data Sheet Features and capabilities Three-channel SMU Four-quadrant operation (±20 V) Maximum current output of 120 ma per channel High measurement sensitivity

More information

INSTRUCTION MANUAL. Instruction Manual. Analog Multi-Tube Vortexer Digital Multi-Tube Vortexer

INSTRUCTION MANUAL. Instruction Manual. Analog Multi-Tube Vortexer Digital Multi-Tube Vortexer INSTRUCTION MANUAL Instruction Manual Analog Multi-Tube Vortexer Digital Multi-Tube Vortexer Table of Contents Package Contents............ 1 Warranty............ 1 Installation............ 2 Maintenance

More information

MARTINDALE INSTRUCTIONS MM35 DIGITAL MULTIMETER ELECTRIC. Trusted by professionals

MARTINDALE INSTRUCTIONS MM35 DIGITAL MULTIMETER ELECTRIC. Trusted by professionals Martindale Electric will carry out routine calibration (on a chargeable basis) if the instrument is returned, carriage paid, to the address on the final page of this document. Alternatively, a chargeable

More information

Model 2380 Rack-Mount Kit

Model 2380 Rack-Mount Kit Keithley Instruments 28775 Aurora Road Cleveland, Ohio 44139 1-800-935-5595 http://www.tek.com/keithley Model 2380 Rack-Mount Kit Installation Instructions Introduction The Model 2380 Fixed Rack-Mount

More information

OPR Power Series AC to DC POWER SUPPLY SERIES WITH REMOTE MANAGEMENT AND ALARM SYSTEMS. Model Nos. OPR065-48S / OPR065-48R. Manual

OPR Power Series AC to DC POWER SUPPLY SERIES WITH REMOTE MANAGEMENT AND ALARM SYSTEMS. Model Nos. OPR065-48S / OPR065-48R. Manual OPR Power Series AC to DC POWER SUPPLY SERIES WITH REMOTE MANAGEMENT AND ALARM SYSTEMS Model Nos. OPR065-48S / OPR065-48R Manual Revision F July 2009 Optimal Power Supplies LLC www.optimal-power.com i

More information

EPS Power Supply

EPS Power Supply EPS - 600 Power Supply Installation and Operation Manual Version 1.0 *This instrument is intended for laboratory use only Index A. Important Notice ----------------------------------------------------------------

More information

1-36V, 0-3A DC Power Supply

1-36V, 0-3A DC Power Supply 1550 1-36V, 0-3A DC Power Supply User Manual Safety Summary The following safety precautions apply to both operating and maintenance personnel and must be followed during all phases of operation, service,

More information

F-712.PM1 Optical Power Meter

F-712.PM1 Optical Power Meter MP165E, applies to F-712.PM1 F-712.PM1 Optical Power Meter Optical Power Meter for 400-1550 nm Wavelength Range, to 1 ma Input Current, 20 khz Signal Bandwidth, Logarithmic Output ±5 V, Benchtop Device,

More information

38 MHz Passive Voltage Probe R&S RT-ZP1X

38 MHz Passive Voltage Probe R&S RT-ZP1X Manual 38 MHz Passive Voltage Probe R&S RT-ZP1X 1333.1370.02 Printed in Germany Test and Measurement 2 Manufacturer ROHDE & SCHWARZ For comprehensive information about Rohde and Schwarz, please visit our

More information

Autoranging Mini Multimeter Model MN16A

Autoranging Mini Multimeter Model MN16A User's Guide Autoranging Mini Multimeter Model MN16A Introduction Congratulations on your purchase of the Extech MN16A Autoranging Multimeter. This meter measures AC/DC Voltage, AC/DC Current, Resistance,

More information

R5050. Model. Instruction Manual. TRMS AC/DC Clamp Meter. reedinstruments. www. com

R5050. Model. Instruction Manual. TRMS AC/DC Clamp Meter. reedinstruments. www. com Model R5050 TRMS AC/DC Clamp Meter Instruction Manual reedinstruments com Table of Contents Safety... 3 Features... 4 Specifications...4-6 Instrument Description...7-8 Measurement Procedures...9-12 Battery

More information

Z-350 FAZER USER MANUAL

Z-350 FAZER USER MANUAL www.clubsoundrent.nl Z-350 FAZER USER MANUAL English Français Deutsch 2013 Antari Lighting and Effects Ltd. 1 User Manual Safety Information Please read the following safety information carefully before

More information

Installation Guide. QBox-V6. Standalone/Spare V6 SDI QBox. Standalone/Spare V6 SDI QBox. Part No. A

Installation Guide. QBox-V6. Standalone/Spare V6 SDI QBox. Standalone/Spare V6 SDI QBox. Part No. A Installation Guide Standalone/Spare V6 SDI QBox QBox-V6 Standalone/Spare V6 SDI QBox Part No. A9009-0004 EN www.autocue.com Copyright 2017 All rights reserved. Original Instructions: English All rights

More information

CLAMP MULTIMETER METRACLIP 85 ENGLISH. Start Guide

CLAMP MULTIMETER METRACLIP 85 ENGLISH. Start Guide CLAMP MULTIMETER METRACLIP 85 ENGLISH Start Guide Clamp Multimeter METRACLIP 85 English You have just acquired an METRACLIP 85 clamp multimeter and we thank you. For best results from your device : read

More information

Earth Resistance and Resistivity Tester

Earth Resistance and Resistivity Tester User Manual Earth Resistance and Resistivity Tester Model GRT350 Additional User Manual Translations available at www.extech.com Introduction Thank you for selecting the Extech Instruments Model GRT350

More information

P5200A Series High Voltage Differential Probes. Installation and Safety Instructions & Product Documentation CD

P5200A Series High Voltage Differential Probes. Installation and Safety Instructions & Product Documentation CD xx P5200A Series High Voltage Differential Probes ZZZ Installation and Safety Instructions & Product Documentation CD *P071288902* 071-2889-02 Copyright Tektronix. All rights reserved. Licensed software

More information

RS Stock No Instruction Manual RS Input Data Logging Thermometer

RS Stock No Instruction Manual RS Input Data Logging Thermometer RS Stock No. 730-0458 Instruction Manual RS-1384 4 Input Data Logging Thermometer EN FR IT DE ES TABLE OF CONTENTS / EN TITLE TABLE OF CONTENTS PAGE 1. INTRODUCTION FEATURE... 1 2. SPECIFICATIONS... 2

More information

Quick Start Guide. 240 Series Cryogenic Sensor Input Module. 1 Model 240 Quick Start Guide

Quick Start Guide. 240 Series Cryogenic Sensor Input Module. 1 Model 240 Quick Start Guide Quick Start Guide 240 Series Cryogenic Sensor Input Module 1 Model 240 Quick Start Guide 2 Model 240 Quick Start Guide Safety Precautions Observe these general safety precautions during all phases of instrument

More information

SAFETY, ENVIRONMENTAL, AND REGULATORY INFORMATION. NI CompactDAQ Four-Slot Controller with Quad-Core Processor

SAFETY, ENVIRONMENTAL, AND REGULATORY INFORMATION. NI CompactDAQ Four-Slot Controller with Quad-Core Processor SAFETY, ENVIRONMENTAL, AND REGULATORY INFORMATION NI cdaq -9136 NI CompactDAQ Four-Slot Controller with Quad-Core Processor This document includes compliance precautions and connection information for

More information

ATK-2040 AC/DC TRMS Watt Clamp Meter Users Manual

ATK-2040 AC/DC TRMS Watt Clamp Meter Users Manual ATK-2040 AC/DC TRMS Watt Clamp Meter Users Manual EN 61010-2-032 CAT II 600V, CAT III 300V Pollution Degree 2 SYMBOLS showed on the clamp meter or in this manual: Caution, risk of danger. Refer to accompanying

More information

OX 5022-CK OX 5042-CK

OX 5022-CK OX 5042-CK QUICK START USER GUIDE OX 5022-CK OX 5042-CK Statement of Compliance Chauvin Arnoux, Inc. d.b.a. AEMC Instruments certifies that this instrument has been calibrated using standards and instruments traceable

More information

Model INSTRUCTION MANUAL DIGITAL MULTIMETER

Model INSTRUCTION MANUAL DIGITAL MULTIMETER Model 57040 INSTRUCTION MANUAL DIGITAL MULTIMETER SAFETY INFORMATION This multimeter has been designed according to IEC 1010 concerning electronic measuring instruments with an overvoltage category (CAT

More information

User's Guide. Extech AM A AC Analog Clamp Meter

User's Guide. Extech AM A AC Analog Clamp Meter User's Guide Extech AM300 300A AC Analog Clamp Meter Introduction Congratulations on your purchase of the Extech AM300 Analog Clamp Meter. This device measure AC Voltage and Current, DC Voltage, and Resistance.

More information

Installation RA5112-C-16A-C20. Basic Rack Power Distribution Unit

Installation RA5112-C-16A-C20. Basic Rack Power Distribution Unit Installation RA5112-C-16A-C20 Basic Rack Power Distribution Unit Contents Before You Begin........................1 Safety and grounding information..........1 How to Install the Rack PDU...............2

More information

SUBWOOFER SYSTEM YST-MSW10

SUBWOOFER SYSTEM YST-MSW10 ACTIVE SERVO PROCESSING SUBWOOFER SYSTEM YST-MSW10 Active Servo SUBWOOFER SYSTEM YST-MSW10 Active Servo HIGH CUT HIGH LOW OWNER S MANUAL MANUAL DE INSTRUCCIONES CAUTION RISK OF ELECTRIC SHOCK DO NPT OPEN

More information

YST-SW20 SUBWOOFER SYSTEM OWNER S MANUAL. Active Servo Technology

YST-SW20 SUBWOOFER SYSTEM OWNER S MANUAL. Active Servo Technology CAUTION SUBWOOFER SYSTEM Active Servo RISK OF ELECTRIC SHOCK DO NOT OPEN CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK DO NOT REMOVE COVER (OR BACK). NO USER-SERVICEABLE PARTS SIDE. REFER SERVICG TO QUALIFIED

More information

The power behind competitiveness. Delta Infrasuite Power Management. Power Distribution Unit. User Manual.

The power behind competitiveness. Delta Infrasuite Power Management. Power Distribution Unit. User Manual. The power behind competitiveness Delta Infrasuite Power Management Power Distribution Unit User Manual www.deltapowersolutions.com Save This Manual This manual contains important instructions and warnings

More information

COGNEX. Checker SensorView. Quick Reference Guide

COGNEX. Checker SensorView. Quick Reference Guide COGNEX Checker SensorView Quick Reference Guide 890 SensorView 890 Overview SensorView 890 provides self-contained IP-65 touchscreen configuration, control, and monitoring of one or more Checker 4G series

More information

HCS-3600 / 3602 / 3604 Laboratory Grade & High RFI Immunity Switching Mode Power Supply with Rotary Encoder Control

HCS-3600 / 3602 / 3604 Laboratory Grade & High RFI Immunity Switching Mode Power Supply with Rotary Encoder Control HCS-3600 / 3602 / 3604 Laboratory Grade & High RFI Immunity Switching Mode Power Supply with Rotary Encoder Control 1. INTRODUCTION User Manual This family of efficient, upgraded SMPS with small form factor,

More information

Model 7705 Control Module

Model 7705 Control Module www.keithley.com Model 7705 Control Module User s Guide PA-696 Rev. D / October 2006 A G R E A T E R M E A S U R E O F C O N F I D E N C E Safety Precautions The following safety precautions should be

More information

Keithley Instruments Customer Documentation Series 2600A UL Safety Supplement

Keithley Instruments Customer Documentation Series 2600A UL Safety Supplement Keithley Instruments, Inc. 28775 Aurora Road Cleveland, Ohio 44139 1-888-KEITHLEY www.keithley.com Keithley Instruments Customer Documentation Series 2600A UL Safety Supplement 1. Introduction The Keithley

More information

ST-140 Vibration Meter ST-140D Datalogging Vibration Meter User s Manual

ST-140 Vibration Meter ST-140D Datalogging Vibration Meter User s Manual ST-140 Vibration Meter ST-140D Datalogging Vibration Meter User s Manual HB2ST1400000 CONTENTS 1 Introduction... 1 2 Accessories... 1 3 Safety Precaution... 1 4 Meter Description... 2 5 Operation... 3

More information

1. Safety Precautions (Read these precautions before use.)

1. Safety Precautions (Read these precautions before use.) R P5102S/N/N1 HMI Installation Guide Thank you for purchasing FATEK HMI. Before installing or operating the unit, please read this installation guide carefully to ensure correct use. 1. Safety Precautions

More information

TT-SI 50 50MHz DIFFERENTIAL PROBE USER S MANUAL

TT-SI 50 50MHz DIFFERENTIAL PROBE USER S MANUAL TT-SI 50 50MHz DIFFERENTIAL PROBE USER S MANUAL This probe is in compliance with IEC-1010.1, IEC-1010.2-031 CAT I or CAT II, Pollution Degree 2. 1. Safety Terms and Symbols Terms appear in this manual:

More information

CVU-200-KIT. 200 V Bias Tee Kit. Description. Parts list / October 2014 *P A* 1

CVU-200-KIT. 200 V Bias Tee Kit. Description. Parts list / October 2014 *P A* 1 Keithley Instruments 28775 Aurora Road Cleveland, Ohio 44139 1-800-935-5595 http://www.keithley.com CVU-200-KIT 200 V Bias Tee Kit Description The CVU-200-KIT Bias Tee Kit consists of three 2600-RBT-200

More information

Part No. Z , IA Jul OPERATION MANUAL. High Voltage Digitalmeter A

Part No. Z , IA Jul OPERATION MANUAL. High Voltage Digitalmeter A Part No. Z1-109-820, IA001705 Jul. 2016 OPERATION MANUAL High Voltage Digitalmeter 149-10A Use of Operation Manual Please read through and understand this Operation Manual before operating the product.

More information

High Precision Quad Output DC Power Supply

High Precision Quad Output DC Power Supply User's Guide High Precision Quad Output DC Power Supply Model 382270 Introduction Thank you for selecting the Extech Model 382270. This device is shipped fully tested and calibrated and, with proper use,

More information

Keysight U8030 Series Triple-Output DC Power Supplies

Keysight U8030 Series Triple-Output DC Power Supplies Keysight U8030 Series Triple-Output DC Power Supplies Data Sheet Introduction Higher Power. Better Reliability. Unrivalled Performance. Keysight Technologies, Inc. extends its family of basic DC power

More information

USER MANUAL. True RMS Multimeter. Extech EX430A

USER MANUAL. True RMS Multimeter. Extech EX430A USER MANUAL True RMS Multimeter Extech EX430A Introduction Congratulations on your purchase of the Extech EX430A True RMS Autoranging Multimeter. This meter measures AC/DC Voltage, AC/DC Current, Resistance,

More information

DLRO 200 High Current, Low Resistance Ohmmeter

DLRO 200 High Current, Low Resistance Ohmmeter M DLRO 200 High Current, Low Resistance Ohmmeter USER MANUAL GSAFETY WARNINGS THESE SAFETY WARNINGS MUST BE READ AND UNDERSTOOD BEFORE THE INSTRUMENT IS USED. n DLRO200 is supplied without a plug terminating

More information