Can eliminate static charge over an extensive range

Size: px
Start display at page:

Download "Can eliminate static charge over an extensive range"

Transcription

1 No.BK-P3 Static Electricity Removing Unit Ionizer Wide Area Fan Type Overhead Fan Type Can eliminate static charge over an extensive range Wide area fan type RoHS compliant product Overhead fan type

2 Static Electricity Removing Unit Ionizer Wide Area Fan Type Features Air supply is not required, and two types can be chosen depending on the installation location and application. Can eliminate static charge over an extensive range. Exhibits stable, long-term performance in eliminating static charge thanks to a newly developed AC ( Hz) format. and discharge needle unit can be removed by one touch, without any tools. Airflow can be controlled by adjusting the airflow volume. Safety is ensured by the detection of abnormal electrical discharge and overcurrent. Top display panel POWER (power indicator LED: green) RUN (operation indicator LED: green) Airflow volume adjustment FAN SPEED (airflow indicator LED: green) (Three fan motors type) (Two fan motors type) Front of the unit FAN LOCK (fan abnormality indicator LED: red) O.C. (overcurrent detection indicator LED: red) P.D. (electrical discharge abnormality detection indicator LED: red) Back of the unit Discharging needle unit Filter/filter cover Front of the unit Front display panel FAN SPEED (airflow indicator LED: green) Airflow volume adjustment RUN (operation indicator LED: green) O.C. (overcurrent detection indicator LED: red) P.D. (electrical discharge abnormality detection indicator LED: red) POWER (power indicator LED: green) Back of the unit Filter/filter cover 1

3 Static Electricity Removing Unit Ionizer Overhead Fan Type Features Overhead fan type ionizer for which air supply is not required. Can eliminate static charge over an extensive range. Exhibits stable, long-term performance in eliminating static charge thanks to a newly developed AC ( Hz) format. and discharge needle unit can be removed by one touch, without any tools. Airflow can be controlled with the air flow rate adjusting knob. Safety is ensured by the detection of abnormal electrical discharge. Outlet side Filter/filter cover Back side 5.5 [.17] mounting hole 1 [.7] mounting hole Side of the unit Display panel POWER (power indicator LED: green) FLOW (air flow rate adjusting knob) H.V. ALARM (high voltage abnormality indicator LED: red) Power input connector

4 Graphs of static charge removal characteristics/ranges of static charge removal Wide area fan type Static charge elimination Static Static charge time elimination () time time () Wide area fan type Static charge elimination Static Static charge time elimination () time time () Overhead fan type 1 Static charge elimination Static Static charge time elimination () time time () Static charge elimination characteristics Static charge elimination characteristics Static charge elimination characteristics Measured distance Static charge elimination characteristics Static charge elimination characteristics 5 5 Static charge elimination characteristics Measured distance Static charge elimination characteristics Measured distance Static charge elimination characteristics Static charge elimination characteristics Static charge elimination time to to Static charge elimination time to to Static charge elimination time to to Static charge elimination time to to Static charge elimination time to to to to 7 to 7 7 to to to 8 9 to 8 to to 8 to to to 1 8 to to 1 8 to 1 1 mm =.39 in to 1 1 to 1 1 to to 1 1 to Static charge elimination time to to Static charge elimination time to to to to to 8 to to 1 8 to to 1 1 to 1 Note 1: The static charge removing characteristics are measured by in-house test standard using the charged plate monitor of pf, 15 mm [5.9 in]. : The static charge removal time means decaying time from 1 V to 1 V at the max. flow rate. 3: These values are measured values and not guaranteed values. : Static charge elimination characteristics are values for the center of the unit. 3

5 Specifications Wide area fan type Item Model Input voltage VDC 5% Consumption current A Output voltage kv 7.5 Indicator LED Output POWER (green) RUN (green) FAN SPEED (green) P.D. (red) O.C. (red) Lit when power is on Lit when high voltages are applied to electrodes Displayed as 5 levels of fan airflow Lit when there is an electrical discharge abnormality (RUN LED turns off) Lit when there is an overcurrent in the high voltage circuit (RUN LED turns off) FAN LOCK (red) Lit when there is a fan abnormality Contact output when red LED is lit (contact b, max. of VDC, 5 ma) Ion balance Note 1 V 5 Static charge elimination time Note 1 sec. 1. or less 1.5 or less Amount of ozone generated Note ppm. or less Maximum airflow Fan power m 3 /min [ft 3 /min] 3. fan [11.99 fan] 3. 3 fan [ fan] Control Smooth control with airflow volume adjustment External dimensions Note 3 mm [in] 37 [1.] (W) 159 [.3] (H) 78.5 [3.91] (D) 5 [.3] (W) 1 [5.7] (H) 9.5 [.73] (D) Weight Note kg [lb] 1.7 [3.78] 3.1 [.83] Usage environment Indoor to C [ to 1 F], 15 to 85% RH (with no condensation) Accessories Installation manual, AC adaptor, output signal lead wires (set of ), cleaning brush for discharge needle 1 bracket set ( mounted on unit, included) Note 1: 3 mm [11.8 in] from the center of the fan outlet, at maximum flow rate. : 15 mm [5.9 in] from the center of the fan outlet, at maximum flow rate. 3: When protrusions and brackets removed. : Including brackets. Remark: Ion balance and static charge removal time were measured by in-house test standard. Contact us for more detail. Overhead fan type Item Model Input voltage 1 to VAC 5/ Hz Power consumption VA Output voltage kv 7.5 Indicator LED POWER (green) H.V. ALARM (red) Lit when power is on Lit when there is a high voltage abnormality Ion balance Note 1 V 1 Static charge elimination time Note 1 sec.. or less Amount of ozone generated Note ppm.5 or less Maximum airflow Fan power m 3 /min [ft 3 /min]. 3 fan [11. 3 fan] Control Smooth control with air flow rate adjusting knob External dimensions Note 3 mm [in] 1 [] (W).5 [.38] (H) 15 [5.9] (D) Weight kg [lb] 5. [11.3] Usage environment Indoor to C [ to 1 F], 15 to 85% RH (with no condensation) Accessories Installation manual, AC cable, cleaning brush for discharge needle Note 1: 5 mm [17.7 in] from the center of the fan outlet, at maximum flow rate. : 15 mm [5.9 in] from the center of the fan outlet, at maximum flow rate. 3: When protrusions removed. Remark: Ion balance and static charge removal time were measured by in-house test standard. Contact us for more detail.

6 Order codes Wide area fan type Unit (two fan motors type) (three fan motors type) AC adaptor (included) * Output signal lead wires (included) * Output signal lead wires (included) AC adaptor (included) Options (sold separately) Replacement discharge needle unit (quantity: 1) Replacement filter (quantity: set of ) Filter cover (quantity: 1) DTY-ZEM-FA DTY-ZFR-FA DTY-ZFRC-FA (quantity: 1) DTY-ZL-FA1 (for ) DTY-ZL-FA (for ) Output signal lead wires ( m [.5 ft]) DTY-ZSL-FA Bracket (1 set) DTY-ZBK-FA1 (for ) * knob bolts included DTY-ZBK-FA (for ) * knob bolts, rubber gaskets included AC adaptor DTY-ZPS3 Rated Input: 1 to VAC Input: 5/ Hz 1. A Output: VDC.1 A Unit Overhead fan type (three fan motors, overhead fan type) AC cable (included) Options (sold separately) Replacement discharge needle unit (quantity: 1) Replacement filter (quantity: set of ) Filter cover (quantity: 1) DTY-ZEM-FA DTY-ZFR-FA DTY-ZFRC-FA (quantity: 1) DTY-ZL-FA 5

7 FAN TYPE IONIZER Dimensions (mm [in]) Wide area fan type Knob bolt Airflow volume adjustment 1 [1.3] 37 [1.] 33 [13.] 3 [1.181] POWER (power indicator LED: green) RUN (operation indicator LED: green) O. C. (overcurrent detection indicator LED: red) FAN LOCK (fan abnormality indicator LED: red) FAN SPEED (airflow indicator LED: green) P. D. (electrical discharge abnormality detection indicator LED: red) 1 [.551] Top panel details (78.5 [3.91]) 51 [.8] Filter Main circuit Inner circuit Filter cover : VDC : ALARM Load AC adaptor MAX 5 ma Output 1: ALARM VDC VDC 3: V : GND Ground External connection side 19.5 [7.5] 159 [.3] 8.5 [.97] 17.5 [5.] 1 [5.] Bracket 387 [15.] 9 [3.53] 9 [3.53] 51 [.8] 5.5 [1.].75 [.187] Mounting hole (3-.5 [.177]) Output signal lead wires (included) AWG (yellow) 5 [ ] Array of the connector's connector pin 1: ALARM : GROUND (green) 5 3: VDC 1 3 : ALARM 5: UNUSED View from arrow A : VDC A 1 [5.] 1 [5.] AC adaptor (included) Power signal connector Ground wire: AWG green Length: mm [79 in] AC adaptor Input: 1 to VAC 5 Hz/ Hz Output: VDC. 1 A molex 555TL AWG (white) Note: If you are using an abnormal output signal, insert the output signal lead wires that were included into the connector pins 1 and for the AC adaptor [ ] molex 555TL 115 [.5] 38 [1.9] 53 [.87] [ 1.99] 17. [.] 1 [5.7] 9 [3.53] 1 [5.] 15 [.9] Bracket 77 [3.31] 19 [7.7] ( [3.8]) 5 [.3] 15 [.9] 15 [.9] 57 [.] 95 [19.5] 19 [7.7] 1 [5.] 1 [5.] 1 [5.] 15 [.9] [.17] mounting holes 5 [1.99] Rubber gasket Knob bolt (9.5 [.73]) 51 [.8] Airflow volume adjustment RUN (operation indicator LED: green) POWER (power indicator LED: green) Array of the connector's connector pin 1: ALARM : GROUND (green) 5 3: VDC 1 3 : ALARM 5: UNUSED View from arrow A : VDC A 15 5 [ ] IONIZER FAN TYPE Front panel details AC adaptor (included) FAN SPEED (airflow indicator LED: green) O. C. (overcurrent detection indicator LED: red) P. D. (electrical discharge abnormality detection indicator LED: red) Ground wire: AWG green Length: mm [79 in] AC adaptor Input: 1 to VAC 5 Hz/ Hz Output: VDC. 1 A 115 [.5] 38 [1.9] [ 1.99] Power signal connector Filter Output signal lead wires (included) 5 [ ] Filter cover AWG (yellow) molex 555TL 53 [.87] : VDC molex 555TL AWG (white) Note: If you are using an abnormal output signal, insert the output signal lead wires that were included into the connector pins 1 and for the AC adaptor. Main circuit : ALARM Load AC adaptor MAX 5 ma Output 1: ALARM VDC VDC 3: V : GND Ground Inner circuit External connection side

8 POWER POWER LOW FLOW Dimensions (mm [in]) Overhead fan type 1 [] 11 [.3] [15.7] [15.7] Filter [.8] (78.5 [3.91]).5 [.38] POWER (power indicator LED: green) Filter cover 1 [.39] 18 [5.] 9 [3.71] [.3] [.17] mounting holes - 1 [.7] mounting hole Power input connector (IEC3-C1) Fuse holder (Fuse: 1 A) H. V. ALARM (high voltage abnormality indicator LED: red) FLOW (air flow rate adjusting knob).8 [.898] 15 [5.9] 1 [5.] 1 [5.] 1 [5.] 1 [.39] 58 [1.] 3.5 [1.1] 87.5 [3.5] 15 [.9] 1 [5.] 15 [.9] 15 [.9] 15 [.9] 15 5 [ ] IEC3-C13 AC cable (included) 15 VAC or less Note: The AC cable that is included is for 1 VAC (15 VAC or less). Provide a suitable power cord separately if you are using over 15 VAC. Handling instructions and precautions (wide area fan type, overhead fan type) Installing 1. When installing, ensure enough space so that the inlet does not get blocked.. Be careful of water and oil contamination, high temperatures, and high humidity. Especially avoid locations on which condensation forms. Cautions during use 1. Be sure to remove the AC adaptor (AC cable for overhead fan types) before doing inspections, cleaning, or maintenance.. Failure to do so may result a high voltage being applied to the discharge needle and causing electric shock. Never touch the discharge needle when the power is on. 3. The tip of the discharge needle is sharp, so be careful when cleaning and when removing the discharge needle unit. Failure to do so may result in injury. Also, be very careful so that the discharge needle does not bend or break. If it does, performance may begin to deteriorate.. Do not disassemble the discharge needle unit. The tip of the discharge needle is sharp, so doing so may result in injury. 5. Maintenance is an extremely important aspect for maintaining performance. Do periodic maintenance because performance may deteriorate when the usage environment is poor (such as an atmosphere with high humidity) or when the discharge needle is not clean. For how to do maintenance, see the instruction manual attached to the product.. The operating life of the discharge needle varies depending on the condition of the usage environment. Maintenance is required because loss of performance may occur when the usage environment is poor (such as an atmosphere with high humidity) or when the discharge needle is not clean. 7. After the power is turned on, it takes about five for the fan's rotation to stabilize. To obtain stable performance in eliminating static charge, avoid using the product in this transitional state. * Read the safety precautions and common precautions on the ionizer general catalog homepage before using this produce. OVERSEAS DEPARTMENT , Midori-cho, Koganei City, Tokyo , Japan Tel: Fax: KOGANEI ASIA PTE. LTD. 9 Ubi Road 1, #5-18 Oxley Bizhub, Singapore 8731 Tel: Fax: KOGANEI (THAILAND) CO., LTD. 33/9, Tower B, Elephant Tower, 1th Fl., Phaholyothin Road, Chomphon, Chatuchak, Bangkok 19, Thailand Tel: Fax: Koganei International America, Inc. 393 Civic Center Drive, Suite 8 Fremont, California 9538 Tel: Fax: URL Note that improvements may result in unannounced changes to the specifications and appearances described here. 1/'1 5 ABAB KOGANEI CORP. PRINTED IN JAPAN

Electrostatic Potential Sensor

Electrostatic Potential Sensor Catalog No. BK-P044 Electrostatic Potential Sensor RoHS compliant product Introducing small sensors perfect for monitoring static electricity in-line! These sensors can constantly monitor and measure the

More information

DTY-EPS DTY-EPU. w e DTY-EPP- - w e. t y. q DTY-EPU PSU-BR DTY-EPP-CC- L DTY-EPS. ZD1 ZD4 Tr1 Tr4

DTY-EPS DTY-EPU. w e DTY-EPP- - w e. t y. q DTY-EPU PSU-BR DTY-EPP-CC- L DTY-EPS. ZD1 ZD4 Tr1 Tr4 DTY-EPU....... DTY-EPS. q DTY-EPU.... DTY-EPS DTY-EPP-- PSU-BR q w ew r DTY-EPP-CC-L D ZDZD TrTr q r w e t y q w e r t y.. w e r 0-00 -- - -- 00--00 t URL http://www.koganei.co.jp y DTY-EPU Thank you very

More information

TOP - 1. Instruction Manual. Version 1.0 Produced in Jan. 2004

TOP - 1. Instruction Manual. Version 1.0 Produced in Jan. 2004 Version 1.0 Produced in Jan. 2004 Instruction Manual LCD monitor IV-08MP Thank you for purchasing the SHARP IV-08MP LCD monitor. Read this introductory instruction manual carefully to thoroughly familiarize

More information

ION BLOWER AMF-AE Series

ION BLOWER AMF-AE Series Instruction Manual ION BLOWER AMF-AE Series Read this instruction manual before using the product in order to achieve maximum performance. Keep this instruction manual within your reach after reading so

More information

TRC-190 User s Manual

TRC-190 User s Manual User s Manual Edition 3.2, May 2017 www.moxa.com/product 2017 Moxa Inc. All rights reserved. User s Manual The software described in this manual is furnished under a license agreement and may be used only

More information

Mid-span 802.3af PoE Injector. Installation Guide KPOE-100

Mid-span 802.3af PoE Injector. Installation Guide KPOE-100 Mid-span 802.3af PoE Injector Installation Guide KPOE-100 Doc. 070521 1 (C) 2005 KTI Networks Inc. All rights reserved. No part of this documentation may be reproduced in any form or by any means or used

More information

Operation Manual. Concorde 600 Power Supply. *This instrument is intended for laboratory use only.

Operation Manual. Concorde 600 Power Supply. *This instrument is intended for laboratory use only. Concorde 600 Power Supply Operation Manual Cat.no. R10-1001011 *This instrument is intended for laboratory use only http://www.recenttec.com E-mail : support@recenttec.com Version 1.1 Packing List x 1

More information

INSTRUCTIONS Operation/Maintenance

INSTRUCTIONS Operation/Maintenance 2257 North Penn Road Hatfield, PA 19440 (215) 997-0590 (800) 538-0750 Fax: (215) 997-3450 INSTRUCTIONS Operation/Maintenance Publication 5200964 (Rev B, February 2007) minion2 Ionizing Air Blower US Patents:

More information

Part No. Z , IA Jul OPERATION MANUAL. High Voltage Digitalmeter A

Part No. Z , IA Jul OPERATION MANUAL. High Voltage Digitalmeter A Part No. Z1-109-820, IA001705 Jul. 2016 OPERATION MANUAL High Voltage Digitalmeter 149-10A Use of Operation Manual Please read through and understand this Operation Manual before operating the product.

More information

DIMENSION/WEIGHT kpa. 0 to 20 m / 0 to 60 ft 0 to 2 bar / 0 to 29 psi. 0 to 50 m / 0 to 160 ft 0 to 5 bar / 0 to 72.5 psi

DIMENSION/WEIGHT kpa. 0 to 20 m / 0 to 60 ft 0 to 2 bar / 0 to 29 psi. 0 to 50 m / 0 to 160 ft 0 to 5 bar / 0 to 72.5 psi V161102 Liquid Level Sensor Sensor for measuring the level of liquid in a well or tank USE / PURPOSE The range of liquid level sensors use pressure to measure the liquid level in a well or tank. The sensors

More information

IGB Series. Operation Manual. Platform Scale. Kg/Lb Specification IMPORTANT

IGB Series. Operation Manual. Platform Scale. Kg/Lb Specification IMPORTANT Platform Scale IGX/ Kg/Lb Specification Operation Manual IMPORTANT Do not carry out installation, operation, service, or maintenance until thoroughly understanding the contents of this manual. Keep this

More information

icore Kiosk system Installation Guide

icore Kiosk system Installation Guide icore Kiosk system Installation Guide The reproduction, transmission or use of this document or its contents is not permitted without express authority. Offenders will be liable for damages. All rights,

More information

EPS Power Supply

EPS Power Supply EPS - 600 Power Supply Installation and Operation Manual Version 1.0 *This instrument is intended for laboratory use only Index A. Important Notice ----------------------------------------------------------------

More information

JANOME DESKTOP ROBOT JR2000N Series. Operation Manual. <Setup> For Qualified Installer ONLY

JANOME DESKTOP ROBOT JR2000N Series. Operation Manual. <Setup> For Qualified Installer ONLY JANOME DESKTOP ROBOT JR2000N Series Operation Manual For Qualified Installer ONLY Thank you for purchasing the Janome Robot. *Read this manual thoroughly in order to properly use this robot. Be sure

More information

DRAFT. Basler Accessories. Technical Specification GP-I/O CABLE 6P/OPEN. Order Number

DRAFT. Basler Accessories. Technical Specification GP-I/O CABLE 6P/OPEN. Order Number DRAFT Basler Accessories Technical Specification GP-I/O CABLE 6P/OPEN Order Number 2000034087 Document Number: DG001133 Version: 03 Language: 000 (English) Release Date: 29 August 2017 Contacting Basler

More information

PIEZO FEEDER CONTROLLER

PIEZO FEEDER CONTROLLER PIEZO FEEDER CONTROLLER Instruction Manual Single-Function Type P212 P312 This Instruction Manual is applicable to Piezo Feeder Controller version 1 and later. Confirm the version information displayed

More information

POWER SUPPLY UNIT PSU-3

POWER SUPPLY UNIT PSU-3 INSTRUCTION MANUAL NEITS INSTRUMENTS CO., LTD. International Division 2013.09 Thank you for purchasing the NEITZ Power Supply Unit PSU-3. This unit has been designed for the use with NEITZ Binocular Indirect

More information

TRC-190 User s Manual

TRC-190 User s Manual First Edition, November 2008 www.moxa.com/product 2008 Moxa Inc. All rights reserved. Reproduction without permission is prohibited. The software described in this manual is furnished under a license agreement

More information

Basler Accessories. Technical Specification POWER-I/O CABLE HRS 6P/OPEN. Order Numbers

Basler Accessories. Technical Specification POWER-I/O CABLE HRS 6P/OPEN. Order Numbers Basler Accessories Technical Specification POWER-I/O CABLE HRS 6P/OPEN Order Numbers 2200000189 2000029411 Document Number: DG001383 Version: 09 Language: 000 (English) Release Date: 24 October 2017 Contacting

More information

DIGITAL TORQUE METER MODEL TME2

DIGITAL TORQUE METER MODEL TME2 DIGITAL TORQUE METER MODEL TME2 OPERATING INSTRUCTION TME2 TME2 Model To use this product properly and safely, please read this manual carefully before use. If you have any question about the product and

More information

Haze 800 DMX. User Guide. English

Haze 800 DMX. User Guide. English Haze 800 DMX User Guide English Introduction Box Contents Haze 800 DMX Remote Control (wired) User Guide Safety & Warranty Manual Support For the latest information about this product (documentation, technical

More information

Operation Manual WARNING. Be sure to read this Operation Manual before use. Universal Space Amusement Equipment Ltd.

Operation Manual WARNING. Be sure to read this Operation Manual before use. Universal Space Amusement Equipment Ltd. WARNING Be sure to read this Operation Manual before use. Universal Space Amusement Equipment Ltd. CONTENTS 1. The company..2 2. Specifications.. 3 3. Package Contents..5 4. Installation, Fix and Transport..6

More information

PDS100 Programmable Dispensing System SAFETY INSTRUCTIONS

PDS100 Programmable Dispensing System SAFETY INSTRUCTIONS PDS100 Programmable Dispensing System INSTRUCTION MANUAL SAFETY INSTRUCTIONS Before using any Fluid Metering, Inc. product read the following safety instructions as well as specific product specifications

More information

Installation Instructions

Installation Instructions Installation Instructions Variable Frequency Drive (VFD) 7 ½ - 25 Ton Units with 2 Wire Control WARNING UNINTENDED EQUIPMENT OPERATION Modifying or changing parame eters whose function is not described

More information

Junos WebApp Secure 5.0 Hardware Guide

Junos WebApp Secure 5.0 Hardware Guide Junos WebApp Secure 5.0 Hardware Guide Junos WebApp Secure 5.0 Hardware Guide This document contains a specification for the MWS1000 hardware appliance, as well as instructions for installation into a

More information

DIO-1616LN-FIT. Features. Specifications. Ethernet Remote I/O F&eIT N Series Isolated Digital Input/Output Unit DIO-1616LN-FIT 1. Ver.1.

DIO-1616LN-FIT. Features. Specifications. Ethernet Remote I/O F&eIT N Series Isolated Digital Input/Output Unit DIO-1616LN-FIT 1. Ver.1. Ethernet Remote I/O F&eIT N Series Isolated Digital / DIO-1616LN-FIT * Specifications, color and design of the products are subject to change without notice. This product is an isolated digital input and

More information

NJ-Series Power Supply Unit NJ-PA/PD

NJ-Series Power Supply Unit NJ-PA/PD NJ-Series Power Supply Unit CSM_NJ-PA_PD_DS_E_1_2 Powerful power supply unit to supply stable power to the NJ-series controller. Stable power supply is available from the NJ-series CPU Unit to each I/O

More information

LEAK CURRENT HiTESTER. Fully Supporting IEC rd Edition and JIS T0601-1:2012 Standards (ST5540 only)

LEAK CURRENT HiTESTER. Fully Supporting IEC rd Edition and JIS T0601-1:2012 Standards (ST5540 only) LEAK CURRENT HiTESTER ST5540/ST5541 Safety standards measuring instruments Fully Supporting IEC 60601-1 3rd Edition and JIS T0601-1:2012 Standards (ST5540 only) Leak Current Measurement - Essential to

More information

Please Read Instruction Carefully Before Installation! Figure 1: A/CO2-DUCT

Please Read Instruction Carefully Before Installation! Figure 1: A/CO2-DUCT Installation and Operation Instructions A/CO2-DUCT Series Please Read Instruction Carefully Before Installation! Figure 1: A/CO2-DUCT PRECAUTIONS REMOVE POWER BEFORE WIRING. NEVER CONNECT OR DISCONNECT

More information

HV-CS kv Edge Mount Triaxial Jack

HV-CS kv Edge Mount Triaxial Jack Keithley Instruments 28775 Aurora Road Cleveland, Ohio 44139 1-800-935-5595 http://www.tek.com/keithley HV-CS-1589 3 kv Edge Mount Triaxial Jack Installation Information Description The Keithley Instruments

More information

EF-S1 SERIES. Continuously check invisible static electricity in lines. Constantly check static in lines!

EF-S1 SERIES. Continuously check invisible static electricity in lines. Constantly check static in lines! 1215 PHOTO PHOTO SAFETY USE SERIES Related Information General terms and conditions... F- General precautions... P.1595 guide... P.1155~ MEASUREMENT panasonic.net/id/pidsx/global Continuously check invisible

More information

Proportional Control Unit (PCU)

Proportional Control Unit (PCU) Proportional Control Unit (PCU) HQ-006 to HQ-300 Installation & Maintenance Manual The EIM HQ Series PCU is a Digital positioner with a Microprocessor and 12-bit A/D converter. By moving the actuator to

More information

Model 2460-KIT. Screw Terminal Connector Kit. Description / September 2014 *P * 1

Model 2460-KIT. Screw Terminal Connector Kit. Description / September 2014 *P * 1 Keithley Instruments 28775 Aurora Road Cleveland, Ohio 44139 1-800-935-5595 http://www.keithley.com Model 2460-KIT Screw Terminal Connector Kit Description The Model 2460-KIT Screw Terminal Connector Kit

More information

Installation Job Aid for Ethernet Routing Switch 5900 Series

Installation Job Aid for Ethernet Routing Switch 5900 Series Installation Job Aid for Ethernet Routing Switch 5900 Series Notices NN47211-301 Issue 05.01 November 2017 Notice paragraphs alert you about issues that require your attention. The following paragraphs

More information

Instruction Manual. M Pump Motor Controller. For file reference, please record the following data:

Instruction Manual. M Pump Motor Controller. For file reference, please record the following data: Instruction Manual M Pump Motor Controller For file reference, please record the following data: Model No: Serial No: Installation Date: Installation Location: When ordering replacement parts for your

More information

S-100X / S-200X Snow Machine User Manual

S-100X / S-200X Snow Machine User Manual S-100X / S-200X Snow Machine User Manual English Français Deutsch 中文 2014 Antari Lighting and Effects Ltd. 1 2 User Manual Antari S-100X & S-200X Snow Machine Introduction Thank you for choosing an ANTARI

More information

RZ2 BioAmp Processor. Operator s Manual

RZ2 BioAmp Processor. Operator s Manual RZ2 BioAmp Processor Operator s Manual RZ2 BioAmp Processor Operator s Manual Copyright 2008-2013 Tucker-Davis Technologies, Inc. (TDT). All rights reserved. No part of this manual may be reproduced or

More information

smar Specifications and information are subject to change without notice. Up-to-date address information is available on our website.

smar   Specifications and information are subject to change without notice. Up-to-date address information is available on our website. smar www.smar.com Specifications and information are subject to change without notice. Up-to-date address information is available on our website. web: www.smar.com/contactus.asp PS302P - Fieldbus Power

More information

1. Safety Precautions (Read these precautions before use.)

1. Safety Precautions (Read these precautions before use.) R P5102S/N/N1 HMI Installation Guide Thank you for purchasing FATEK HMI. Before installing or operating the unit, please read this installation guide carefully to ensure correct use. 1. Safety Precautions

More information

Electronic Balance Ionizer STABLO-AP Service Manual

Electronic Balance Ionizer STABLO-AP Service Manual 321-78209 Jan. 2016 Electronic Balance Ionizer STABLO-AP Service Manual Analytical & Measuring Instruments Division This page is intentionally left blank. Table of Contents 1. Precautions for Troubleshooting...

More information

OBIS LX/LS 6-Laser Remote

OBIS LX/LS 6-Laser Remote OBIS LX/LS 6-Laser Remote Laser Remote and Power Supply for up to Six Lasers OBIS LX and OBIS LS laser products come with a variety of accessories to support your application needs. The for OBIS LS and

More information

OPTICAL HEADEND PLATFORM OTOHP-CH 3RU CHASSIS OTOHP-PS POWER SUPPLY MODULE OTOHP-BP BLANK PANEL INSTRUCTION MANUAL

OPTICAL HEADEND PLATFORM OTOHP-CH 3RU CHASSIS OTOHP-PS POWER SUPPLY MODULE OTOHP-BP BLANK PANEL INSTRUCTION MANUAL OPTICAL HEADEND PLATFORM OTOHP-CH 3RU CHASSIS OTOHP-PS POWER SUPPLY MODULE OTOHP-BP BLANK PANEL INSTRUCTION MANUAL Phone: (209) 586-1022 (800) 545-1022 Fax: (209) 586-1026 OTOHP-CH Rev. X1 E-Mail: salessupport@olsontech.com

More information

BS 287 DUAL CHANNEL POWER SUPPLY. User Manual. January 2017 V1.0

BS 287 DUAL CHANNEL POWER SUPPLY. User Manual. January 2017 V1.0 BS 287 DUAL CHANNEL POWER SUPPLY User Manual January 2017 V1.0 Table of contents 1.0 SAFETY INSTRUCTIONS... 3 2.0 GENERAL DESCRIPTION PS 289... 4 3.0 MECHANICAL INSTALLATION... 5 4.0 MAINS POWER & SAFETY

More information

Fan Type Ionizer. IZF10R Series

Fan Type Ionizer. IZF10R Series PRODUCT NAME Fan Type Ionizer MODEL / Series / Product Number IZF10R Series Contents Safety Instructions... 2 1. How to Order... 7 1-1. Product... 7 1-2. Accessories... 7 1-3. Maintenance parts... 8 1-4.

More information

Part No. Z , IA Nov OPERATION MANUAL. High Voltage Digitalmeter A

Part No. Z , IA Nov OPERATION MANUAL. High Voltage Digitalmeter A Part No. Z1-109-920, IA001723 Nov. 2005 OPERATION MANUAL High Voltage Digitalmeter 149-30A Use of Operation Manual Please read through and understand this Operation Manual before operating the product.

More information

Features: S98-B v1.0 S98-B 9-port switch with buffer power supply for 8 IP cameras

Features: S98-B v1.0 S98-B 9-port switch with buffer power supply for 8 IP cameras S98-B v1.0 S98-B 9-port switch with buffer power supply for 8 IP cameras Edition: 3 from 15.11.2017 Supercedes the edition: 2 from 09.01.2017 EN** Features: Uninterruptible power supply of 8 IP cameras

More information

CONTENTS PRODUCT FEATURES... EG-2 SAFETY PRECAUTIONS... EG-2 PARTS DESCRIPTION... EG-3 INSTALLATION AND ADJUSTMENT... EG-4 SPECIFICATIONS...

CONTENTS PRODUCT FEATURES... EG-2 SAFETY PRECAUTIONS... EG-2 PARTS DESCRIPTION... EG-3 INSTALLATION AND ADJUSTMENT... EG-4 SPECIFICATIONS... Thank you for your purchase of this product. Before operating the product, please read this instruction manual carefully to ensure proper use of the product. Please store this instruction manual in a safe

More information

SmartBlock I/O Module HE579MIX577/977 Isolated 4/8 Analog Inputs 2/4 Analog Outputs

SmartBlock I/O Module HE579MIX577/977 Isolated 4/8 Analog Inputs 2/4 Analog Outputs MAN0969-02 PAGE 1 Mix577/977 Module ` SmartBlock I/O Module HE579MIX577/977 Isolated 4/8 Analog Inputs 2/4 Analog Outputs 1 SPECIFICATIONS Analog Inputs High Resolution Steady State Current 120mA @ 24v

More information

E3S-A. Built-in Amplifier Photoelectric Sensor (Medium Size) Ordering Information. Built-in Amplifier Photoelectric Sensors. Horizontal. 7 m.

E3S-A. Built-in Amplifier Photoelectric Sensor (Medium Size) Ordering Information. Built-in Amplifier Photoelectric Sensors. Horizontal. 7 m. Built-in Amplifier (Medium Size) ES-A CSM_ES-A_DS_E Be sure to read Safety Precautions on page 0. Ordering Information Built-in Amplifier s Red light Infrared light Sensing method Appearance Connection

More information

OPERATING MANUAL FOR THE 30KV A.C. TEST SET P123. Bicotest High Voltage Products Ltd

OPERATING MANUAL FOR THE 30KV A.C. TEST SET P123. Bicotest High Voltage Products Ltd OPERATING MANUAL FOR THE 30KV A.C. TEST SET P123 Product: High Voltage AC Test Set Type: P123 Bicotest High Voltage Products Ltd Hellesdon Park Road, Drayton High Road, Norwich NR6 5DR United Kingdom Phone

More information

Installation Manual INTELLIGENT SERVER. Model name: BMS-LSV6UL

Installation Manual INTELLIGENT SERVER. Model name: BMS-LSV6UL Model name: BMS-LSV6UL INTELLIGENT SERVER Thank you very much for purchasing this TOSHIBA INTELLIGENT SERVER. Please read this manual carefully beforehand for proper installation of the SERVER. NOTE This

More information

MCCB-500 MOLDED-CASE CIRCUIT BREAKER TESTER

MCCB-500 MOLDED-CASE CIRCUIT BREAKER TESTER MCCB-500 MOLDED-CASE CIRCUIT BREAKER TESTER USER S MANUAL Vanguard Instruments Company, Inc. 1520 S. Hellman Ave. Ontario, California 91761, USA TEL: (909) 923-9390 FAX: (909) 923-9391 January 2015 Revision

More information

KPW-T2P25. PoE Splitter. Industrial IEEE 802.3at High Power. User s Manual -1- DOC

KPW-T2P25. PoE Splitter. Industrial IEEE 802.3at High Power. User s Manual -1- DOC KPW-T2P25 Industrial IEEE 802.3at High Power PoE Splitter User s Manual DOC.121011-1- (C) 2012 KTI Networks Inc. All rights reserved. No part of this documentation may be reproduced in any form or by any

More information

SP SP-T-9

SP SP-T-9 INSTALLATION INSTRUCTIONS Revision B1 Rapid City, SD, USA, 04/2010 MODELS 201-100-SP 201-200-SP 201-200-SP-T-9 II_201-SP_B1 2880 North Plaza Drive, Rapid City, South Dakota 57702 (800) 843-8848 (605) 348-5580

More information

Instruction Sheet Board Style Low Water Cutoff

Instruction Sheet Board Style Low Water Cutoff Instruction Sheet Board Style Low Water Cutoff 102-305 SUPERSEDES: REVISION E DATED December 12, 2007 #5401173-REV F PLANT ID 001-3902 US Patents 6,904,800, 7,243,540, and 7,317,993 Other Patents Pending

More information

General-Purpose Photoelectric Sensor

General-Purpose Photoelectric Sensor General-Purpose Photoelectric Sensor Compact Limit Switch Style with Universal Supply FET output allows for solid state switching of AC or DC Universal AC/DC power supply Choose cable or connector types

More information

Mechanically Activated Device for Dry Run Protection in Applications with LORENTZ Solar Pump Systems

Mechanically Activated Device for Dry Run Protection in Applications with LORENTZ Solar Pump Systems Well Probe Mechanically Activated Device for Dry Run Protection in Applications with LORENTZ Solar Pump Systems The switch can be used to detect the water level within a well. When the water level in the

More information

Solder terminals D2FD-2L0-1H D2FD-01L0-1H. PCB terminals D2FD-2L0-1T D2FD-01L0-1T. Hinge lever Solder terminals D2FD-2L1-1H D2FD-01L1-1H

Solder terminals D2FD-2L0-1H D2FD-01L0-1H. PCB terminals D2FD-2L0-1T D2FD-01L0-1T. Hinge lever Solder terminals D2FD-2L1-1H D2FD-01L1-1H Ultra subminiature and dust proof Sealing by using rubber packing means the switch can be used in dust-proof environments (IEC IP6X). Switch rating of 2 A at 125 VAC possible with a single-leaf movable

More information

Application Package Dimension Output Input Output Output Protection Option Code Code Power Voltage Quantity Voltage Type (W) (VAC) (VDC)

Application Package Dimension Output Input Output Output Protection Option Code Code Power Voltage Quantity Voltage Type (W) (VAC) (VDC) Automation Datacom IPC Industry Measurement Telecom Automobile Boat Charger Medical PV Railway PART NUMBER STRUCTURE T A H 450 U S 12 - F2 Application Package Dimension Output Input Output Output Protection

More information

Model 7705 Control Module

Model 7705 Control Module www.keithley.com Model 7705 Control Module User s Guide PA-696 Rev. D / October 2006 A G R E A T E R M E A S U R E O F C O N F I D E N C E Safety Precautions The following safety precautions should be

More information

Installation Job Aid for Ethernet Routing Switch 3600 Series

Installation Job Aid for Ethernet Routing Switch 3600 Series Installation Job Aid for Ethernet Routing Switch 3600 Series Notices NN47213-303 Issue 03.01 November 2017 Notice paragraphs alert you about issues that require your attention. Following are descriptions

More information

Leak Current Measurement - Essential to Electrical Safety. Compliance with IEC :2005 Ed 3.0, JIS T :2012

Leak Current Measurement - Essential to Electrical Safety. Compliance with IEC :2005 Ed 3.0, JIS T :2012 LEAK CURRENT HiTESTER ST5540, ST5541 Leak Current Measurement - Essential to Electrical Safety Uninterrupted polarity switching function dramatically reduces cycle time Support for rated currents up to

More information

Installation RA5112-C-16A-C20. Basic Rack Power Distribution Unit

Installation RA5112-C-16A-C20. Basic Rack Power Distribution Unit Installation RA5112-C-16A-C20 Basic Rack Power Distribution Unit Contents Before You Begin........................1 Safety and grounding information..........1 How to Install the Rack PDU...............2

More information

The 3-phase, 5-wire model name is PF LNM. The 3-phase, 4-wire model name is PF LNN.

The 3-phase, 5-wire model name is PF LNM. The 3-phase, 4-wire model name is PF LNN. The 12.5kW power shelf accepts 3-phase input power and provides stable DC output power (1000A at 12.5VDC). The OCP 21-inch power shelf includes a total of 5+5 high-power, hot-swappable PSUs in redundant

More information

Slim Relay G2RV. Model Number Structure. Ordering Information. Model Number Legend. List of Models. Relay and Socket Combinations

Slim Relay G2RV. Model Number Structure. Ordering Information. Model Number Legend. List of Models. Relay and Socket Combinations Slim Relay G2RV The World's First Industrial Slim Relay Large plug-in terminals for reliable connection. LED indicator and mechanical flag to check operation. Transparent housing enables checking relay

More information

E3S-A. Built-in Amplifier Photoelectric Sensor (Medium Size) Ordering Information. Built-in Amplifier Photoelectric Sensors. Horizontal. 7 m.

E3S-A. Built-in Amplifier Photoelectric Sensor (Medium Size) Ordering Information. Built-in Amplifier Photoelectric Sensors. Horizontal. 7 m. Built-in Amplifier (Medium Size) ES-A Be sure to read Safety Precautions on page 0. Ordering Information Built-in Amplifier s Red light Infrared light Sensing method Appearance Connection method Sensing

More information

DVI Splitter Amplifier DS01. User s Manual. Preliminary version Copyright 2012 SHENZHEN BIGTIDE TECHNOLOGY CO., LTD

DVI Splitter Amplifier DS01. User s Manual. Preliminary version Copyright 2012 SHENZHEN BIGTIDE TECHNOLOGY CO., LTD BIGTIDE SERVICE DOCUMENT DVI Splitter Amplifier DS01 Preliminary version Copyright 2012 SHENZHEN BIGTIDE TECHNOLOGY CO., LTD Contents 1. INTRODUCTION...2 2. SAFETY PRECAUTIONS...2 3. TECHNICAL INFORMATION...4

More information

Technical Manual Nova: Cabinet Security Management System (CSMS)

Technical Manual Nova: Cabinet Security Management System (CSMS) Technical Manual Nova: Cabinet Security Management System (CSMS) KP_nova_TM_160501_EN 1 Publication May, 2016, Keyprocessor BV Paasheuvelweg 20 1105BJ Amsterdam, The Netherlands www.keyprocessor.com/nova

More information

RZ5/RZ5D/RZ6 Processor. Operator s Manual

RZ5/RZ5D/RZ6 Processor. Operator s Manual RZ5/RZ5D/RZ6 Processor Operator s Manual RZ5/RZ5D/RZ6 Processor Operator s Manual Copyright 2010-2013 Tucker-Davis Technologies, Inc. (TDT). All rights reserved. No part of this manual may be reproduced

More information

OPERATING INSTRUCTIONS

OPERATING INSTRUCTIONS OPERATING INSTRUCTIONS 4103 COMPACT 24V DC IONIZING STATIC BAR GB Static Clean static control equipment has been designed to give you many years of productive service. However, the science of static control

More information

OPERATING INSTRUCTIONS PA AMPLIFIER P-1812

OPERATING INSTRUCTIONS PA AMPLIFIER P-1812 OPERATING INSTRUCTIONS PA AMPLIFIER P-1812 Please follow the instructions in this manual to obtain the optimum results from this unit. We also recommend that you keep this manual handy for future reference.

More information

TOSLINE-S20 Active Star Coupler Instruction Manual

TOSLINE-S20 Active Star Coupler Instruction Manual TOSLINE - S20 Active Star Coupler Instruction Manual September, 1995 Toshiba International Corporation UM-TLS20**-E004 Table of Contents 1. Introduction... 2 2. Overview... 3 3. Specifications... 4 3.1

More information

Micro-Ohmmeter. Digital 200A. Model Measure low resistance with high accuracy

Micro-Ohmmeter. Digital 200A. Model Measure low resistance with high accuracy Digital 200A Micro-Ohmmeter Model 6290 Measure low resistance with high accuracy Accurately measures low contact resistances with test currents up to 200A Measures resistances from 0 to 20mΩ Resolution

More information

onlinecomponents.com

onlinecomponents.com R General-Purpose Fiber-optic Sensor Compact Limit Switch Style with Universal Supply H FET output allows for solid state switching of AC or DC H Universal AC/DC power supply H Choose cable or connector

More information

Micro-Ohmmeter. Digital 200A. Model Measure low resistance with high accuracy

Micro-Ohmmeter. Digital 200A. Model Measure low resistance with high accuracy Digital 200A Micro-Ohmmeter Model 6290 Measure low resistance with high accuracy Accurately measures low contact resistances with test currents up to 200A Measures resistances up to 20mΩ Low resolution

More information

Voltage Current Front-mounting bracket

Voltage Current Front-mounting bracket Switching Power Supply S8PS Compact DIN-Rail Mounting Industrial Power Supplies with Capacities Up to 600 W Models range from 0 W to 600 W. Universal input: voltage range 0 to 240 VAC. Power Factor Correction

More information

Z-350 FAZER USER MANUAL

Z-350 FAZER USER MANUAL www.clubsoundrent.nl Z-350 FAZER USER MANUAL English Français Deutsch 2013 Antari Lighting and Effects Ltd. 1 User Manual Safety Information Please read the following safety information carefully before

More information

POE084824B. PoE 54V/8x0,3A/4x7Ah PoE buffer power supply for up to 8 IP camera. v.1.1 EN* Edition: 7 from

POE084824B. PoE 54V/8x0,3A/4x7Ah PoE buffer power supply for up to 8 IP camera. v.1.1 EN* Edition: 7 from POE084824B v.1.1 PoE 54V/8x0,3A/4x7Ah PoE buffer power supply for up to 8 IP camera. EN* Edition: 7 from 15.11.2017 Supersedes the edition: 6 from 22.11.2016 GREEN POWER CCTV PoE PSU features: DC 54V uninterruptible

More information

300 WATT, PFC, OPEN FRAME POWER SUPPLIES TABLE 1. OUTPUT RATINGS AND SPECIFICATIONS, RMW 300W SERIES

300 WATT, PFC, OPEN FRAME POWER SUPPLIES TABLE 1. OUTPUT RATINGS AND SPECIFICATIONS, RMW 300W SERIES INSTRUCTION MANUAL KEPCO An ISO 9001 Company. 300 WATT, PFC, OPEN FRAME POWER SUPPLIES RMW 300W SERIES I INTRODUCTION SCOPE OF MANUAL. This instruction manual covers the installation and operation of the

More information

HDMI/HDBT 1x4 Splitter. Installation & Operation Manual. MuxLab Inc A / SE A

HDMI/HDBT 1x4 Splitter. Installation & Operation Manual. MuxLab Inc A / SE A 500424 MuxLab Inc. 2016 94-000808-A / SE-000808-A SAFETY PRECAUTIONS To insure the best from the product, please read all instructions carefully before using the device. Save this manual for further reference.

More information

Single-Output 2000 W GPIB

Single-Output 2000 W GPIB Single-Output 2000 W GPIB 6671A - 6675A Fast, low-noise outputs Analog control of output voltage and current Fan-speed control to minimize acoustic noise Built-in measurements and advanced programmable

More information

* * Agilent Power Distribution Unit (PDU) Installation Guide

* * Agilent Power Distribution Unit (PDU) Installation Guide Agilent Power Distribution Unit (PDU) Installation Guide For use with Agilent PDU kits and PDU installation kits for Agilent instrument racks June 2008 Edition 7 E0608 *5000-0039* 5000-0039 Notice The

More information

DP700 Series. Programmable Linear DC Power Supply. Batter Fly s.r.l. - Tel

DP700 Series. Programmable Linear DC Power Supply. Batter Fly s.r.l. - Tel DP700 Series Programmable Linear DC Power Supply DP711: single output, 30 V/5 A, total power up to 150 W DP712: single output, 50 V/3 A, total power up to 150 W Low ripple and noise: DP711:

More information

Features: DSB98 v1.0 DIN rail mounted switch 9-port DSB98 with buffer power supply for 8 IP cameras

Features: DSB98 v1.0 DIN rail mounted switch 9-port DSB98 with buffer power supply for 8 IP cameras DSB98 v1.0 DIN rail mounted switch 9-port DSB98 with buffer power supply for 8 IP cameras Edition: 4 from 15.11.2017 Supercedes the edition: 3 from 30.03.2017 EN** Features: Uninterruptible power supply

More information

Single Kernel Grain Moisture Tester PQ-520. (type PQ ) Operating Instructions

Single Kernel Grain Moisture Tester PQ-520. (type PQ ) Operating Instructions Single Kernel Grain Moisture Tester PQ-520 (type PQ-5205-1) Operating Instructions Single Kernel Grain Moisture Tester Safety Precautions Not following the safety precautions could cause an accident resulting

More information

Linear Positioning Stage Reference Manual

Linear Positioning Stage Reference Manual PP-30 Series Linear Positioning Stage PP-30 Piezo Positioner Stage Rev 3.00 MICRONIX USA, LLC 15375 Barranca Parkway, E-106 Irvine, CA 92618 Tel: 949-480-0538 Fax: 949-480-0538 Email: info@micronixusa.com

More information

Part No. Z , IA Mar OPERATION MANUAL. High Voltage Digitalmeter A

Part No. Z , IA Mar OPERATION MANUAL. High Voltage Digitalmeter A Part No. Z1-109-820, IA001704 Mar. 2011 OPERATION MANUAL High Voltage Digitalmeter 149-10A Use of Operation Manual Please read through and understand this Operation Manual before operating the product.

More information

E2A. Ordering Information. Cylindrical Proximity Sensor. Safe Mounting with Greater Sensing Distance. E2A Cylindrical Proximity Sensor 1

E2A. Ordering Information. Cylindrical Proximity Sensor. Safe Mounting with Greater Sensing Distance. E2A Cylindrical Proximity Sensor 1 Cylindrical Proximity Sensor E2A Safe Mounting with Greater Sensing Distance Ensures a sensing distance approximately 1. to 2 times larger than that of any conventional OMRON Sensor. Problems such as the

More information

Oil-resistive, Long-range Photoelectric Sensor with Metal Housing

Oil-resistive, Long-range Photoelectric Sensor with Metal Housing Oil-resistive, Long-range with Metal Housing ES-C Water- and Oil-resistive with Metal Housing Used for Long-range Sensing Satisfies the water- and oil-resistive requirements and safe enough for use in

More information

RoHS APPROVAL SHEET 15V/2.0A SERIES NO. (M04) EA1030CU CUSTOMER CUSTOMER P/N DESCRIPTION EDAC MODEL DATE REVISION 0 APPROVED DESIGN PREPARE

RoHS APPROVAL SHEET 15V/2.0A SERIES NO. (M04) EA1030CU CUSTOMER CUSTOMER P/N DESCRIPTION EDAC MODEL DATE REVISION 0 APPROVED DESIGN PREPARE APPROVAL SHEET CUSTOMER CUSTOMER P/N DESCRIPTION EDAC MODEL 15V/2.0A SERIES NO. (M04) EA1030CU DATE 2013-04-01 REVISION 0 APPROVED DESIGN PREPARE RoHS CONCLUSION APPROVED CONDITON CUSTOMER S APP D SIGNATURE:

More information

Rotary version, three-position control

Rotary version, three-position control 4 622 Residential Air damper actuators GXD..31.1 Rotary version, three-position control Electric motor-driven actuators for three-position control 1.5 Nm nominal torque AC 24 V or AC 230 V rated voltage

More information

Series LC6D/LC6C. LJ1 LG1 LC1 LX LC6D/LC6C Switches LC6C LC6D. Series LX Dedicated Stepper Motor Driver and Positioning Driver

Series LC6D/LC6C. LJ1 LG1 LC1 LX LC6D/LC6C Switches LC6C LC6D. Series LX Dedicated Stepper Motor Driver and Positioning Driver Series LCD To power supply Stepper Motor Driver LCD Electric Actuator Series LCC Series LX Dedicated Stepper Motor Driver and Positioning Driver Series LCD/LCC PLC Positioning unit (Not incl. To be provided

More information

Features: DSFB108 v1.1 DIN rail mounted switch 10-ports DSFB108 with buffer power supply for 8 IP cameras

Features: DSFB108 v1.1 DIN rail mounted switch 10-ports DSFB108 with buffer power supply for 8 IP cameras DSFB108 v1.1 DIN rail mounted switch 10-ports DSFB108 with buffer power supply for 8 IP cameras Edition: 3 from 07.03.2018 Supercedes the edition: 2 from 15.11.2017 EN** Features: Uninterruptible power

More information

EMC1600 Series Media Converter and Ethernet Extender Chassis

EMC1600 Series Media Converter and Ethernet Extender Chassis EMC1600 Series Media Converter and Ethernet Extender Chassis User s Manual Preface This manual describes how to install and use the 16-Bay Media Converter and Ethernet Extender Chassis. This chassis is

More information

NIR Moisture Analyzer KB-30

NIR Moisture Analyzer KB-30 NIR Moisture Analyzer KB-30 Operation Manual Safety Precautions FPL950701 Improper use of the NIR moisture analyzer in violation of the following safety notes may result in death, injury or damage to property

More information

RT02 Series Robust Industrial Joystick. RunnTech

RT02 Series Robust Industrial Joystick. RunnTech Electronics (Changzhou) Corp. RT0 Series Robust Industrial Joystick RT0 Series Robust Industrial Joystick Product Features Potentiometer sensor or Hall sensor; Single axis, dual axis or axis control; Resistant

More information

CDD4 Duct Carbon Dioxide Transmitter

CDD4 Duct Carbon Dioxide Transmitter Drill or punch a 1-1/8 or 1-1/4 hole in the duct at the preferred location and insert the probe into the hole to mark the enclosure mounting holes. Remove the unit and drill the four mounting holes. Clean

More information

HP UPS R/T3000 ERM. Overview. Precautions. Installation Instructions

HP UPS R/T3000 ERM. Overview. Precautions. Installation Instructions HP UPS R/T3000 ERM Installation Instructions Overview The ERM consists of two battery packs in a 2U chassis. The ERM connects directly to a UPS R/T3000 or to another ERM. Up to two ERM units can be connected.

More information

1. Safety Precautions. 2. Components. 3. Notes on Installation. Caution. Warning

1. Safety Precautions. 2. Components. 3. Notes on Installation. Caution. Warning 1. Safety Precautions The following precautions and directions are measures against possible accidents and injuries. Please read them thoroughly before using this product. Warning Neglecting the following

More information

Classification Enclosure rating Input voltage Type of

Classification Enclosure rating Input voltage Type of Slim Relay G2RV The World's First Industrial Slim Relay Large plug-in terminals for reliable connection. LED indicator and mechanical flag to check operation. Special input type with gold plated contacts.

More information