The PM1000 series is a universal 4 digit LED plug-on display for transmitters with 4-20mA 2 wire output and fitted with DIN43650 connector.
|
|
- Alisha Malone
- 5 years ago
- Views:
Transcription
1 PM1000 SERIES PLUG-ON DISPLAY BRIGHT LED DISPLAY INDICATION RANGE -999 TO FITS TO DIN CONNECTOR PLUG-ON TO ANY TRANSMITTER WITH 4-20MA OUTPUT EASY TO SCALE ON SITE ROBUST DESIGN SET POINT OPTION The PM1000 series is a universal 4 digit LED plug-on display for transmitters with 4-20mA 2 wire output and fitted with DIN43650 connector. The plug-on display simply fits between the transmitter plug and connecting cable socket and is powered from the 4-20mA current loop signal of the transmitter. No additional power is required. Display settings are stored in non-volatile EEPROM, and can be easily modified through the menu using two programming buttons. Calibration parameters (zero, span, decimal point position, filter, and set-point level) can all be reprogrammed and stored and retained when power is removed. The display assembly inside the enclosure can be rotated through 90º steps, which will suit any mounting angle and simply installation. Model PM1000 is the standard version. An integral open-drain switch output is provided on model PM1001. This can be programmed to open or close at a set-point level. The output can then by used to trigger an alarm or provided external controller. Typical applications for the plug-on display include use on pressure, temperature, level, RH, or flow transmitters for local readout, alarm activation or control. Adaptations for custom connectors can be made and available on request. Fax: +44 (0) Tel: +44 (0) sales@esi-tec.com
2 PM1000 SERIES PLUG-ON DISPLAY SPECIFICATION DISPLAY: 4 digit red LED display, 7mm digit height. DISPLAY OUTPUT RANGE: -999 to 9999 INPUT SIGNAL: 4-20mA, 2 wire current loop. DISPLAY CALIBRATION: Factory set to display 4.00 to for 4-20mA input. ACCURACY: 0.2% of full-scale input +/- 1 digit POWER SUPPLY VOLTAGE: Requires 5 V or less from loop supply. ALLOWED LOOP CURRENT: Maximum 60mA. Above this automatic circuit protection is activated. DISPLAY SAMPLING RATE: 300mS to 25.5 S, adjustable filter setting from menu. OPEN DRAIN SWITCH OUTPUT: Model number PM1001 only: P type MOSFET switch. Maximum current source: 90mA, with automatic circuit protection. PROGRAMMING: Via two press buttons, menu assisted. Access to the programming buttons is made by removing front cover. MENU SELECTION: Zero adjustment: -999 to 9999 Span adjustment: 0 to 9999 Decimal point: 3 positions or off Filter: 0.3 to 25.5 second Over-range: On/Off Setpoint: -999 to 9999 Setpoint direction: Up/Down Settings stored in Non-volatile EEPROM ERROR MESSAGES: When over-range option is selected: HI is displayed when input is above 20mA LO is displayed when input is less than 4mA when over-range option is off: ErC6 is displayed when range -999 to 9999 is exceeded. TEMPERATURE RANGE: Operating: - 10 C to + 60 C Storage: - 30 C to + 80 C CASE MATERIAL: Moulded ABS plastic, Red Acrylic display widow, Nitrile seal. INGRESS PROTECTION TYPE: Splash-proof, enclosure sealed to IP65 ELECTRICAL CONNECTION: Plugs directly onto transmitters with 4-20 ma output and right-angle DIN (3-pin +earth) connector plug. DIMENSIONS (in mm) PROGRAMMING To setup display: Remove 4 screws and front cover to access programming buttons ORDER DETAILS State model number. Model No. PM1000 PM1001 Standard plug-on display. Plug-on display with single set point. ELECTRICAL CONNECTIONS Pin No. PM1000 PM supply +supply mA signal -supply 3 not connected open drain (P type switch) Connected through to transducer plug CALIBRATION All products manufactured by Ellison Sensors are calibrated using precision calibration equipment with traceability to international standards. Ellison Sensors operates a policy of continuous product development. We reserve the right to change specification without prior notice.
3 PM8000 SIMPLE TO USE PROCESS INDICATOR 3 1/2 DIGIT LED PROCESS METER WIDE RANGE OF SCALABILITY 4-20mA, 0-10 & 1-5V DC PROCESS SIGNALS EXCELLENT STABILITY/ACCURACY DUAL SLOPE ADC DECIMAL POINT DISPLAY Model shown PM8004 The PM8000 offers you a simple process indicator ideal for general monitoring applications. The wide range of scalability provided makes this panel meter suitable for displaying of many different physical variables such as temperature, pressure, weight, humidity etc. The 3digit red LED Display has an accuracy of 0.1% ± 1 count and accepts standard process signals of 4-20mA, 1-5V and 0-10V and many others. A regulated 24V (rated 30mA) or 10V (rated 50mA) sensor supply is readily available on the input connector which can be used to power an external sensor. Jumper switches can be used to select 10V or 24V. Detachable screw connectors are provided to allow easy maintenance and installation. Zero and Span can be finely trimmed with a multi-turn potentiometer. Dual slope integration is employed to give ±1999 count resolution for ±20mA or ±10V analogue input signals. A decimal point can be selected to appear where required by a push-on jumper switch. Optional features include variable display brightness control, remote decimal point selection using remote switching and an extra fixed zero digit to multiply the reading by 10. Sensor House, Wrexham Technology Park, Wrexham, LL13 7YP, Wales, UK
4 PM8000 SPECIFICATION DISPLAY: 4 digit red LED display, 14.2mm digit height. RESOLUTION: 1 in 2000 maximum over full range, with 3 1/2 Digit Display (0 to +/- 1999) INPUT SIGNAL: 4-20mA, 0+/-20mA, 0+/-1mA, 0-10Vdc,0+/-10Vdc, 1-5Vdc,...others possible on request. INPUT RESISTANCE: 13ohms for current input, 1 Mohms for voltage COMMON MODE REJECTION: 100dB 0-60Hz, 250V max ADC METHOD: Dual slope conversion SPEED OF RESPONSE: Display update: 2.5/sec ACCURACY: 0.10% of reading +/- 2 counts TEMPERATURE STABILITY: 100 ppm/ºc for span, 50 ppm/ºc fo zero OUTPUT FOR EXTERNAL SENSORS: 24Vdc or 10V ACCURACY OF THE EXCITATION SUPPLY: +/-20% accuracy CURRENT CAPACITY OF THE EXCITATION SUPPLY: 30mA for 24V, 50mA for 10V POWER SUPPLY: 110 or 240 Vac standard, 11 to 30Vdc as option. POWER CONSUMPTION: 4VA maximum TEMPERATURE RANGE: Operating: 0 C to + 50 C Storage: - 10 C to + 70 C HUMIDITY: 90% RH maximum at 40ºC, non-condensing ELECTROMAGNETIC-COMPATIBILTY: Emissions EN Immunity EN Certification CE marked ELECTRICAL CONNECTION: 4 way detachable screw terminal connector for conductor size 0.5 to 1.5mm BEZEL SIZE: 96mm wide x 48mm high (1/8 DIN) CUTOUT SIZE: 92mm wide x 45 mm high DEPTH BEHIND PANEL: 93 mm minimum required WEIGHT: 300 grams typically CASE MATERIAL: Black polycarbonate DIMENSIONS (in mm) ORDER DETAILS State model number. No options with this panel meter Model No. PM /2 Digit Scalable Process Meter CALIBRATION All products manufactured by Ellison Sensors are calibrated using precision calibration equipment with traceability to international standards. Ellison Sensors operates a policy of continuous product development. We reserve the right to change specification without prior notice. Sensor House, Wrexham Technology Park, Wrexham, LL13 7YP, Wales, UK
5 PM8001 PM8002 PM MA, 0-10V & 0-5V DC & 1-5V PROCESS SIGNALS 3 1/2 & 4 1/2 DIGIT DISPLAY FORMATS EXCELLENT STABILITY/ACCURACY REGULATED SENSOR SUPPLY ZERO & SPAN ADJUSTMENTS LARGE RANGE OF OUTPUT FORMATS Model shown PM8004 OPTIONAL FEATURES The PM8001, PM8002 and PM8003 are an extremely versatile range of process meters providing the solution to most process monitor and readout needs. PM8001 has a 3digit display ranging from 0 to PM8001 and PM8002 have 4digit displays ranging from 0 to 19999, with accuracy of 0.05%. All have 14.2mm high, bright red LED readout as standard. Optional readout colours are available. Input signals options include 4-20mA, 0-10V, 1-5V and 0-5V, with other possible on request. Specify input type when ordering. Many output options are available in this range. These include analogue signal output for re-transmission, setpoint alarm relays, serial data output. Specify output type when ordering. Traditional screwdriver trimming potentiometers are used for calibration and alarm level setting on this product. This provides an uncomplicated, quick approach to setting operating parameters during installation.
6 PM8001 PM8002 PM8003 SPECIFICATION DISPLAY: High intensity red LED display, 14.2mm digit height. RESOLUTION: 3 1/2 Digit model PM /2 Digit models PM8002, PM8003 INPUT SIGNAL: 4-20mA, 0-10Vdc, 1-5Vdc, 0-5Vdc...others possible on request. INPUT RESISTANCE: 24ohms for current input, 1.1Mohms for voltage SPEED OF RESPONSE: Display update: 2.5/sec DECIMAL POINT SELECTION: Set position with push-on jumpers at rear ACCURACY: 0.05% of reading +/- 1 count PM8001 +/-10 counts PM8002/3 TEMPERATURE STABILITY: 50 ppm of range/ºc span and zero OUTPUT FOR EXTERNAL SENSORS: Selectable 10 or 24Vdc, regulated. Others possible, including constant current. ACCURACY OF THE EXCITATION SUPPLY: +/-5% accuracy. Stability is 50ppm/C typical CURRENT CAPACITY OF THE EXCITATION SUPPLY: 120mA for 10V, 30mA for 24V POWER SUPPLY: 110 or 230 Vac standard, 24Vac and 10 to 30Vdc as option. CURRENT CONSUMPTION: 8VA maximum TEMPERATURE RANGE: Operating: - 20 C to + 50 C Storage: - 40 C to + 70 C HUMIDITY: 90% RH maximum at 40ºC, non-condensing ELECTROMAGNETIC-COMPATIBILTY: Emissions EN Immunity EN Certification CE marked ELECTRICAL CONNECTION: 4 way detachable screw terminal connector for conductor size 0.5 to 1.5mm BEZEL SIZE: 96mm wide x 48mm high (1/8 DIN) CUTOUT SIZE: 92mm wide x 45 mm high DEPTH BEHIND PANEL: 125 mm minimum required WEIGHT: 550 grams typically CASE MATERIAL: UL 94V0 rated black ABS OPTIONS (spec): ANALOGUE OUTPUT DRIVE CAPACITY: 4-20mA into loads 0-500ohms. 0-10V into loads from 500ohms to Infinity ANALOGUE OUTPUT ISOLATION: 380V safety rated from power & earth, but not isolated from input stage ANALOGUE OUTPUT SPEED OF RESPONSE: 500 milliseconds. ANALOGUE OUTPUT ACCURACY: 0.05% of range ANALOGUE OUTPUT LINEARITY: 0.01% of range ALARM RELAYS: 2 SPCO relays with adjustable hysteresis. Set HIGH or LOW. De-energise on alarm for fail safe RELAY CURRENT RATING: 7A, resistive load. If driving inductive loads, MOV varistors are recommended RELAY VOLTAGE RATING: 250Vac, 24Vdc ALARM SET-POINT STABILITY: +/- 100 ppm/ºc typical ALARM SPEED OF RESPONSE: 15mS typical ALARM HYSTERESIS: 1 count (PM8001), 10 counts (PM8002/3) ALARM ANNUNCIATION: Red LED illuminates when relay de-energises SERIAL OUTPUT FORMAT: 1 start bit, 8 data bits, 1or more stop bits. ASCII data terminated with a carriage return BAUD RATE: Selectable 1200, 2400, 4800 or 9600 DIMENSIONS (in mm) ORDER DETAILS State model number, input signal and output option if required. Model No. PM8001 PM8002 PM /2 digits. 2 programmable alarms 4 1/2 digits. No alarms 4 1/2 digits. 2 programmable alarms OPTIONS Analogue Output. 4-20mA, 0-10Vdc, +/-5Vdc Alarm Output. 2 SPCO Relay Serial Output. RS232 CALIBRATION All products manufactured by Ellison Sensors are calibrated using precision calibration equipment with traceability to international standards. Ellison Sensors operates a policy of continuous product development. We reserve the right to change specification without prior notice.
7 PM mA, 0-10V, 1-5V & 0-10mA INPUT/ DISPLAY RANGES SIMPLE TO PROGRAM 8 PROGRAM MEMORY OPTION 5 DIGIT LED DISPLAY EXCELLENT STABILITY/ACCURACY ISOLATED 24Vdc SENSOR EXCITATION 10 POINT USER-DEFINED LINEARISATION DIRECT ACCESS MENU FUNCTIONS FOR CALIBRATION, ALARM SETTING AND MORE The PM8004 series of digital panel meters are the ideal solution for measurement display and control applications, and are well suited to the readout and display of physical properties such as pressure, strain, temperature, humidity and others. A MENU-FREE calibration system is employed with this panel meter design. This makes calibration and set-up of operating parameters very straightforward and radically simplifies this process compared with the usual complex menu arrangement used on most digital meters. In the PM8004 the menu is replaced by simple push buttons enabling the zero, span, analogue output or alarms to be adjusted via a button on the front of the panel. The 5 digit red LED display is standard, providing 1 in resolution and an accuracy of 0.05% of range. Inputs include 4-20mA, 0-10V, 1-5V and 0-10mA. A 24V sensor excitation supply is provided and can be used to power an external transmitter current loop. Additionally a linearisation feature is provided with10 user-defined points, which can be used to improve display accuracy with non-linear input signals. Standard features include: Peak and valley memories to record max/min readings and which can be viewed using the MAX/MIN button on the front panel or by using remote contact closure switches. Automatic zero-drift compensation used to cancel long-term drift caused by ageing and temperature change etc. Calibration counter and tamper detector, in which an internal totaliser counts each calibration. This is then stored in non-volatile memory, which cannot be reset, making this a useful function to track calibration history. Finally a reset command can be used to clear any stored data. As a safety precaution for stored data, a 'lock-out' switch has been incorporated into the design to ensure that if this switch is enabled, no data can be lost. Options include 2 or 4 programmable alarm relay outputs, analogue outputs for signal retransmission, RS232 serial or BCD outputs.
8 PM8004 SPECIFICATION DISPLAY: High intensity red LED display, 14.2mm digit height. RESOLUTION: 1 in maximum over full range, with 5 Digit Display ( ) INPUT SIGNAL: 4-20mA,0-10mA, 0-10Vdc, 1-5Vdc,...others possible on request. INPUT RESISTANCE: 33ohms for current input, 1.1Mohms for voltage SPEED OF RESPONSE: Display update: 2/sec FILTERING / SMOOTHING: Selectable time constant of 0 to 5 seconds ACCURACY: 0.05% of reading TEMPERATURE STABILITY: 50 ppm/ºc for span, 20/ºC for zero OUTPUT FOR EXTERNAL SENSORS: 24Vdc, isolated ACCURACY OF THE EXCITATION SUPPLY: +/-20% accuracy. CURRENT CAPACITY OF THE EXCITATION SUPPLY: 50mA for 24V POWER SUPPLY: 95 to 265 Vac standard, 11 to 30Vdc as option.. CURRENT CONSUMPTION: 8VA maximum TEMPERATURE RANGE: Operating: - 20 C to + 50 C Storage: - 40 C to + 70 C HUMIDITY: 90% RH maximum at 40ºC, non-condensing ELECTROMAGNETIC-COMPATIBILTY: Emissions EN Immunity EN Certification CE marked ELECTRICAL CONNECTION: 4 way detachable screw terminal connector for conductor size 0.5 to 1.5mm BEZEL SIZE: 96mm wide x 48mm high (1/8 DIN) CUTOUT SIZE: 92mm wide x 45 mm high DEPTH BEHIND PANEL: 125 mm minimum required WEIGHT: 300 grams typically CASE MATERIAL: UL 94V0 rated black ABS OPTIONS (spec): ANALOGUE OUTPUT DRIVE CAPACITY: 4-20mA into loads 0-500ohms. 0-10V into loads from 500ohms to Infinity ANALOGUE OUTPUT ISOLATION: 250V optically isolated ANALOGUE OUTPUT SPEED OF RESPONSE: 100 milliseconds. ANALOGUE OUTPUT ACCURACY: 0.1% of range ANALOGUE OUTPUT LINEARITY: 0.02% of range ALARM RELAYS: 2 or 4 SPCO relays with adjustable hysteresis. Set HIGH or LOW. De-energise on alarm for fail safe RELAY CURRENT RATING: 5A, resistive load. If driving inductive loads, MOV varistors are recommended RELAY VOLTAGE RATING: 250Vac, 24Vdc ALARM SET-POINT STABILITY: +/- 100 ppm/ºc typical ALARM SPEED OF RESPONSE: 15mS typical SERIAL OUTPUT FORMAT: 1 start bit, 8 data bits, 1 or more stop bits. ASCII data terminated with a carriage return BAUD RATE: Selectable 1200, 2400, 4800 or 9600 DIMENSIONS (in mm) ORDER DETAILS State model number, and option. MODEL NO. PM8004 PM8004-2AL PM8004-4AL PM8004-AN5V PM8004-AN10V PM8004-AN20 PM8004-RS232 PM8004-DIFF PM8004-BCD Standard, no alarms 2 programmable alarms 4 programmable alarms No alarms. 0-5Vdc external O/P No alarms. 0-10Vdc external O/P No alarms. 4-20mA external O/P No alarms. RS232 external O/P No alarms. 4-20mA diff. external O/P No alarms. BCD external O/P All models, up to 5 programmable digits. CALIBRATION All products manufactured by Ellison Sensors are calibrated using precision calibration equipment with traceability to international standards. Ellison Sensors operates a policy of continuous product development. We reserve the right to change specification without prior notice.
9 PM8005 PM mA, 0-10V, 1-5V etc PROCESS SIGNALS 5 DIGIT LED DISPLAY EXCELLENT STABILITY/ACCURACY DIRECT ACCESS MENU FUNCTIONS FOR CALIBRATION, ALARM SETTING AND MORE LARGE RANGE OF STANDARD FEATURES Model shown PM8004 The PM8005 and PM8006 digital panel meters are simplified versions of the popular PM8004 digital process meter family offering the same high performance standards as the PM8004 but with a trimmed down feature list. A MENU-FREE calibration system is employed with this panel meter design. This makes calibration and set-up of operating parameters very straightforward and radically simplifies this process compared with the usual menu arrangement used on most digital meters. The menu in this case is replaced by simple push buttons enabling zero, span, analogue output or alarms to be adjusted via a button on the front of the panel. The 5 digit red LED display is standard, providing +/ count resolution and an accuracy of 0.10% of range. Input signals include 4-20mA, 0-10V, 1-5V and 0-10mA. A 24V sensor excitation supply is provided and can be used to power an external transmitter current loop. Standard features include: digital signal filtering, automatic zero-drift compensation, last digit rounding (count by 1, 2, 5, 10, 20, 50), minimum (valley) and maximum (peek) reading memory, display taring, two set-point alarm relays with latching or adjustable hysteresis, calibration counter and taper detector.
10 PM8005 PM8006 SPECIFICATION DISPLAY: High intensity red LED display, 14.2mm digit height. RESOLUTION: +/ counts maximum over full range, with 5 Digit Display ( to ) INPUT SIGNAL: 4-20mA,0-10mA, 0-10Vdc, 1-5Vdc,...others possible on request. INPUT RESISTANCE: 33ohms for current input, 1.1Mohms for voltage SPEED OF RESPONSE: Display update: 2.5/sec FILTERING / SMOOTHING: Selectable time constant of 0 to 5 seconds ACCURACY: 0.1% of reading +/-2 counts TEMPERATURE STABILITY: 100 ppm/ºc for span, 50/ºC for zero OUTPUT FOR EXTERNAL SENSORS: 24Vdc ACCURACY OF THE EXCITATION SUPPLY: +/-20% accuracy. CURRENT CAPACITY OF THE EXCITATION SUPPLY: 30mA for 24V POWER SUPPLY: 95 to 265 Vac standard, 11 to 30Vdc as option.. CURRENT CONSUMPTION: 8VA maximum TEMPERATURE RANGE: Operating: 0 C to + 50 C Storage: - 10 C to + 70 C HUMIDITY: 90% RH maximum at 40ºC, non-condensing ELECTROMAGNETIC-COMPATIBILTY: Emissions EN Immunity EN Certification CE marked ELECTRICAL CONNECTION: 4 way detachable screw terminal connector for conductor size 0.5 to 1.5mm BEZEL SIZE: 96mm wide x 48mm high (1/8 DIN) CUTOUT SIZE: 92mm wide x 45 mm high DEPTH BEHIND PANEL: 125 mm minimum required WEIGHT: 300 grams typically CASE MATERIAL: UL 94V0 rated black ABS Programmable alarm on PM8006 only: ALARM RELAYS: 2 SPCO relays with adjustable hysteresis. Set HIGH or LOW. De-energise on alarm for fail safe RELAY CURRENT RATING: 5A, resistive load. If driving inductive loads, MOV varistors are recommended RELAY VOLTAGE RATING: 250Vac, 24Vdc ALARM HYSTERESIS: Settable from 0 to 9998 counts ALARM SET-POINT STABILITY: +/- 100 ppm/ºc typical ALARM SPEED OF RESPONSE: 15mS typical DIMENSIONS (in mm) ORDER DETAILS State model number only. No options available. MODEL NO. PM8005 PM8006 No alarms 2 programmable alarms CALIBRATION All products manufactured by Ellison Sensors are calibrated using precision calibration equipment with traceability to international standards. Ellison Sensors operates a policy of continuous product development. We reserve the right to change specification without prior notice.
LAUREL. Laureate Digital Panel Meter for Process and Ratiometric Signals ELECTRONICS, INC. Features. Description
LAUREL ELECTRONICS, INC. Laureate Digital Panel Meter for Process and Ratiometric Signals Features Reads process signals from ±200 mv to ±600V or ±2 ma to ±5A full scale Ratiometric mode for bridges and
More informationTRACKER 240 SERIES. Load Cell and Weighing Indicators. A Precision Measurement Instrument with Outstanding Features
TRACKER 240 SERIES Load Cell and Weighing Indicators A Precision Measurement Instrument with Outstanding Features TRACKER 240 SERIES INDICATORS Ratiometric Measurement Tare and Auto Transducer Excitation
More informationLAUREL. Laureate Digital Panel Meter for Load Cell & Microvolt Input ELECTRONICS, INC. Features. Description
Description LAUREL ELECTRONICS, INC. Features Laureate Digital Panel Meter for Load Cell & Microvolt Input 20, 50, 100, 250 & 500 mv ranges Span adjust from 0 to ±99,999, zero adjust from -99,999 to +99,999
More informationTRACKER 220 SERIES. Digital Panel Indicators. A Complete Range of Universal Input Digital Panel Indicators for Temperature and Process Measurement
TRACKER 220 SERIES Digital Panel Indicators A Complete Range of Universal Input Digital Panel Indicators for Temperature and Process Measurement TRACKER 220 SERIES INDICATORS Universal Input Analogue Output
More informationThe Tracker 220 Series A Complete Range of Universal Input Digital Panel Indicators for Temperature and Process Measurement
Acquisition Measurement Control The Tracker 220 Series A Complete Range of Universal Input Digital Panel Indicators for Temperature and Process Measurement TRACKER 220 SERIES INDICATORS Universal Input
More informationLAUREL. Laureate RTD Temperature Panel Meter / Controller ELECTRONICS, INC. Features. Description. Specifications
LAUREL ELECTRONICS, INC. Laureate RTD Temperature Panel Meter / Controller Features Factory calibrated for 100Ω platinum, 10Ω copper & 120Ω nickel RTDs 2, 3 or 4-wire connection with lead resistance compensation
More informationLAUREL ELECTRONICS, INC.
LAUREL ELECTRONICS, INC. Laureate RTD Temperature Panel Meter / Controller Features Factory calibrated for 100Ω platinum, 10Ω copper & 120Ω nickel RTDs 2, 3 or 4-wire connection with lead resistance compensation
More informationDigital Indicator Solutions
Digital Indicator Solutions Loop-Powered Attachable Compact Attachable Loop-Powered Smart Compact System Loop-Powered Compact Smart System Intelligent Smart System "Intelligent" Options Dual & Display
More information12-36 VDC/12-24 VAC Power Option 4-Digit Display, 0.56 (14.2 mm) or 1.20 (30.5 mm)
4-20 ma & Relay Output Features 4-20 ma, ± 10 V, TC & RTD Inputs 12-36 VDC/12-24 VAC Power Option 4-Digit Display, 0.56 (14.2 mm) or 1.20 (30.5 mm) 24 VDC @ 200 ma Transmitter Power Supply Options Type
More informationTC Type Range Conformity Error. J -210 C to +760 C (-347 F to F) ±0.09 C (±0.16 F) K -244 C to C (-408 F to F) ±0.1 C (±0.
LAUREL ELECTRONICS, INC. Laureate Thermocouple Panel Meter / Controller Features Factory calibrated for thermocouple types J, K, T, E, N, R, S Entire range of each thermocouple in one scale Highly accurate
More informationUDC 1000 and UDC 1500 MICRO-PRO SERIES UNIVERSAL DIGITAL CONTROLLERS
UDC 1000 and UDC 1500 MICRO-PRO SERIES UNIVERSAL DIGITAL CONTROLLERS EN0I-6041 12/99 PRODUCT SPECIFICATION SHEET OVERVIEW The UDC 1000 and UDC 1500 are microprocessor-based 1/16 DIN and 1/8 DIN controllers
More informationTrident and Trident X2 Digital Process and Temperature Panel Meter
Sign In New User ISO 9001:2008 Certified Quality System Home Products Online Tools Videos Downloads About Us Store Contact Policies Trident and Trident X2 Digital Process and Temperature Panel Meter Products
More informationMICRO SERIES PROCESS DISPLAYS LARGE DIGIT MODELS
The MICRO SERIES PROCESS DISPLAYS LARGE DIGIT MODELS Mighty-5 DPM MODELS Micro-P & Mighty-1 Mighty-1 Micro-P ELECTRO-NUMERICS, INC. Introduction The Electro-Numerics family of Digital Panel Meters and
More informationPD765 TRIDENT. Trident Series Process & Temperature Meters.
PD765 Trident Series Process & Temperature Meters TRIDENT PROCESS & Temp 4-20 ma, ± 10 V, TC & RTD Inputs 4-Digit Display, 0.56 (14.2 mm) or 1.20 (30.5 mm) Type 4X, NEMA 4X, IP65 Front 1/8 DIN Shallow
More informationPD765 TRIDENT. Trident Series Process & Temperature Meters.
PD765 Trident Series Process & Temperature Meters TRIDENT PROCESS & Temp 4-20 ma, ± 10 V, TC & RTD Inputs 4-Digit Display, 0.56" (14.2 mm) or 1.20" (30.5 mm) Linear or Square Root with Low-Flow Cutoff
More informationPU5 5-digit digital panel meter in 96x48 mm (BxH) Universal measuring inputs: Pt100, current, voltage, shunt, thermocouple, resistance
PU5 5-digit digital panel meter in 96x48 mm (BxH) Universal measuring inputs: Pt100, current, voltage, shunt, thermocouple, resistance red display of -9999 99999 digits installation depth: 120 mm without
More informationLAUREL. Laureate Dual-Channel Pulse Input Totalizer With Two Independently Scalable Input Channels & Presets ELECTRONICS, INC. Features.
Description LAUREL ELECTRONICS, INC. Laureate Dual-Channel Pulse Input Totalizer With Two Independently Scalable Input Channels & Presets Features Frequencies up to 1 MHz Totals stored in non-volatile
More informationHIGH-VOLTAGE DC METER
HIGH-VOLTAGE DC METER Javelin D PD644 0-300 VDC input NEMA 4X, IP65 front Scale in engineering units Sunlight readable LED display 4-20 ma analog output Two form C 3 A relays option RS-485 serial communications
More information1/32-DIN TEMPERATURE CONTROLLER INSTALLATION, WIRING AND OPERATION MANUAL FORM 3882
1/32-DIN TEMPERATURE CONTROLLER INSTALLATION, WIRING AND OPERATION MANUAL FORM 3882 This manual is intended for use in support of installation, commissioning and configuration of the 1/32-DIN Temperature
More informationHigh Voltage DC Meter
High Voltage DC Meter Javelin D PD644 0-300 VDC input NEMA 4X, IP65 front Scale in engineering units Sunlight readable LED display 4-20 ma analog output Two form C 3 A relays option RS-485 serial communications
More informationDIGITAL DISPLAY. for Industry Applications. Series PAXD. Key-Features:
DIGITAL DISPLAY for Industry Applications Series PAXD Key-Features: Content: Technical Data.2 Technical Drawing...2 Electrical Connection...3 Plug-In Cards...4 Programming & Software...5 Order Code & Accessories...6-5
More informationY800 Plus Frequency, Rate & Period Meter With dual, independently field-scalable channels
Y800 Plus Frequency, Rate & Period Meter With dual, independently field-scalable channels Description Features Frequencies from 0.005 Hz to 1 MHz 6-digit resolution at update rates up to 25/s Selectable
More informationLAUREL. MAGNA Series Large Digit Displays for Counter / Totalizer Pulse Input ELECTRONICS, INC. Features. Description
LAUREL ELECTRONICS, INC. MAGNA Series Large Digit Displays for Counter / Totalizer Pulse Input Features Choice of 2-1/4", 4", 6" or 8" digit heights Choice of 4 or 6 digits with decimal points Choice of
More informationThe IQ240 panel mount load cell indicator is a precision digital indicator for load cell and strain gauge applications.
IQ240 Panel Mount Load Cell Indicator Data sheet English 1.01 Introduction The IQ240 panel mount load cell indicator is a precision digital indicator for load cell and strain gauge applications. The high
More informationThe IQ300 wall mount load cell indicator is a precision digital indicator for load cell and strain gauge applications.
IQ300 Wall Mount Load Cell Indicator Data sheet English 1.01 Introduction The IQ300 wall mount load cell indicator is a precision digital indicator for load cell and strain gauge applications. The high
More informationSINGLE-CHANNEL PROCESS CONTROLLERS & TEMP. DISPLAYS D3820/D3830 Series
The Digitec Series D3800 Panel Meters offer many features and performance capabilities to suit a wide range of industrial applications. The D3820 and D3830 are available in the ranges of 4-20mA, 0-10 VDC,
More informationDINALOG A 144 x 36 A1400 Light-Strip Indicator
DINALOG A x 6 A00 Light-Strip Indicator -9-0-0 /.00 Front panel dimensions: x 6 mm Light-strip indicator with 7 high-contrast LEDs Red LED display color Digital display range for portrait format: 999 to
More informationadjustment via factory default or directly on the sensor signal display flashing at threshold undercut or /exceedance
Processor-based bargraph with digital display vertical or horizontal MB3 3-digit digital display -199 999 red display, optional green 30 dots bargraph display tricolour adjustment via factory default or
More informationDIGITAL ANZEIGE. for Industry Applications. Series PAXP, PAXDP. Key-Features:
DIGITAL ANZEIGE for Industry Applications Series PAXP, PAXDP Key-Features: Content: Technical Data.2 Technical Drawing...3 Electrical Connection PAXP...3 Electrical Connection PAXDP...4 Plug-in Cards...5
More informationLAUREL. Laureate Pulse or Analog Input Batch Controller Automatic batch control for repetitive liquid fill operations ELECTRONICS, INC.
Description LAUREL ELECTRONICS, INC. Laureate Pulse or Analog Input Batch Controller Automatic batch control for repetitive liquid fill operations Features Available for turbine flow meter pulse signals
More informationdual-line 6-dIGIt process MeteR
dual-line 6-dIGIt process MeteR ProVu Se r i e S provu Model pd6000 0-20 ma, 4-20 ma, 0-5 V, 1-5 V, and ±10 V Inputs NEMA 4X, IP65 Front Universal 85-265 VAC or 12/24 VDC Input Power Large Dual-Line 6-Digit
More informationFEMA ELECTRÓNICA. Series MAG983-X. COUNTERS for IMPULSE signals MAG983-1 MAG983-2 MAG983-3 MAG USER S MANUAL (HT0695-r050705)
COUNTERS for IMPULSES Series MAG983-X COUNTERS for IMPULSE signals FEMA ELECTRÓNICA MAG983-1 MAG983-2 MAG983-3 MAG983-4 IDEAL SOLUTION for impulse counting applications where the operator has no access
More informationElectronic SD1, AS 8, ASR 14, ASR 20
Electronic SD1, AS 8, ASR 14, ASR 20 2 Electronic SD1, AS 8, ASR 14, ASR 20 Contents Page List of contents..................................................... 3 Function and characteristics.........................
More informationSX90 Process Controller
Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without
More informationWall-/Pipe Mounted Universal Process Indicator
Data Sheet SS/_8 Wall-/Pipe Mounted Universal Process Indicator High visibility LED display the clearest view of your process status 0.1% measurement accuracy precise indication of process measurement
More information7511 / / / 711 / / 731 / Preset 27
22 Timers Timers Electronic 23 7511 / 3410 23 6320 / 720-6300 24 ElectRo-MeCH 25 710 / 711 / 720 25 722 / 731 / 732 26 Preset 27 7932 27 Electronic 23 7511 Series 8 digit self powered LCD electronic timer
More informationLAUREL ELECTRONICS, INC.
Description LAUREL ELECTRONICS, INC. Laureate Pulse or Analog Input Batch Controller Automatic batch control for repetitive liquid fill operations Features Available for turbine flow meter pulse signals
More information/8 DIN Universal Process Indicator
Data Sheet SS/_ High visibility LED display the clearest view of your process status.% measurement accuracy precise indication of process measurement Analog and relay outputs as standard alarm and retransmission
More information14 Pressure Measurement. Measuring Devices Description Pressure range Connection Device Page
Measuring Devices Pressure range Connection Device Page Digital display mounting, für niedrige Drücke 0 2. mbar / 2. bar 4 mm tube MPV, MPA.02 portable, hand-operated 0 1 mbar / 10 bar 4 mm tube MHA.03
More informationUSER INSTRUCTION MANUAL FOR LOADCELL TRANSMITTER MODEL TDC/I/0550 (SOFTWARE: VER2A) INDEX
USER INSTRUCTION MANUAL FOR LOADCELL TRANSMITTER MODEL TDC/I/0550 (SOFTWARE: VER2A) INDEX DOCUMENT NO: TDC 0550 MANUAL - 2 1.0) INTRODUCTION. PAGE 2 1.1) ABOUT THIS MANUAL. PAGE 2 1.2) INTRODUCTION. PAGE
More informationContents. Temperature & Process Measurement Indicators Setup Guide
Contents Introduction... 2 Installation... 3 Connections... 5 Connecting the Sensor... 6 Powering the Instrument... 7 Operator Functions... 8 The Setup Menus... 9 Configuration Menu Map... 12 Menu Options...
More informationProcess displays For current and voltage
Features Voltage input TRMS-AC/DC up to 600 V Current input AC/DC 1 A, 5 A and shunt (precision resistor) 60 or 100 mv With 2 or 4 limits Display range can be linearised Min, Max, Hold functions 4 20 ma
More informationDCI3 and DCI4 for Current DCV3 and DCV4 for Voltage
London Electronics Limited Warren Court, Chicksands, Shefford, Bedfordshire SG17 5QB Tel +44(0)1462-850967 Fax +44(0)1462-850968 www.london-electronics.com help@london-electronics.com DC digital panel
More informationLAUREL. Laureate Rate Meter & Totalizer with Functions A+B, A-B, AxB, A/B, A/B-1 ELECTRONICS, INC. Features. Description
Description LAUREL ELECTRONICS, INC. Features Laureate Rate Meter & Totalizer with Functions A+B, A-B, AxB, A/B, A/B-1 Arithmetic functions A+B, A-B, AxB, A/B, A/B-1 applied to rate or total for channels
More informationUDC1200 and UDC1700 MICRO-PRO SERIES UNIVERSAL DIGITAL CONTROLLERS
UDC1200 and UDC1700 MICRO-PRO SERIES UNIVERSAL DIGITAL CONTROLLERS 51-52-03-35 11/06 PRODUCT SPECIFICATION SHEET OVERVIEW The UDC1200 & UDC1700 are microprocessor-based 1/16 DIN and 1/8 DIN controllers
More informationThe LT1300 wall mount load cell indicator is a precision digital indicator for load cell and strain gauge applications.
LT1300 Wall Mount Load Cell Indicator Datasheet English 1.00 Introduction The LT1300 wall mount load cell indicator is a precision digital indicator for load cell and strain gauge applications. The high
More informationDM28 - Economical Digital Process and Strain Gauge Panel Meters
DM28 - Economical Digital Process and Strain Gauge Panel Meters TRANSDUCERS Easily scaled in any engineering units from -19999 to 99999 Large 18mm (.71 ) high red or green display Front panel MIN, MAX
More informationDFI 7000 DIGITAL FORCE INDICATOR USER S GUIDE 1.0 INTRODUCTION 2.0 DESCRIPTION. 2.1 Configuration. 2.2 Specifications
DFI 7000 DIGITAL FORCE INDICATOR USER S GUIDE 1.0 INTRODUCTION The DFI 7000 Signal Conditioner-Indicator is a complete 4-1/2-digit signal conditioner and indicator housed in a 1/8 DIN case. This unit provides
More informationCDR-RH Room CO 2, Temperature and Humidity Sensors (Controllers)
Product sheet SN1.401 Type CDR-RH CDR-RH Room CO 2, Temperature and Humidity Sensors (Controllers) CDR-RH sensors are designed to detect carbon dioxide concentration, relative humidity and temperature
More informationCarbon Monoxide (CO) Gas Detection and Control System
Carbon Monoxide (CO) Gas Detection and Control System DESCRIPTION Gas monitor with built-in carbon monoxide (CO) sensor, wall-mounted, accepts inputs from remote devices such as other gas sensors, temperature
More information1.6. Counters, Panel Meters, Tachometers and Timers. Contents Description Fusion Integrated Machine Control Standards and Certifications...
.6 Contents Standards and Certifications............... Product Selection....................... Technical Data and Specifications........... Dimensions............................ Learn Online Page V3-T-04
More informationStrain Gauge Converter
EN Z-SG General Description Module Z-SG is a strain gauge signal converter. Measurements taken using the 6-wires or 4-wires technique are available through Modbus-RTU serial protocol or the analog output.
More informationC160 Wall-/Pipe Mounted Universal Process Indicator
Data sheet DS/ EN Rev. I Wall-/Pipe Mounted Universal Process Indicator reliable process indicator, wherever it s needed High visibility LED display the clearest view of your process status 0.1% measurement
More informationUniversal power supply
Honeywell UDC1200 and UDC1700 MICRO-PRO SERIES UNIVERSAL DIGITAL CONTROLLERS 51-52-03-35 5/03 PRODUCT SPECIFICATION SHEET OVERVIEW The UDC1200 & UDC1700 are microprocessor-based 1/16 DIN and 1/8 DIN controllers,
More information7561-PSD Manual Portable Battery Powered Indicator
7561-PSD Manual Portable Battery Powered Indicator Lebow Products Inc. 1728 Maplelawn Drive P.O. Box 1089 Troy, Michigan 48084-1089 (800) 803-1164 Phone: (248) 643-0220 FAX: (248) 643-0259 Visit our web
More information9000C INDEX APPLICATION EXAMPLE 1 SPECIFICATION 2 SAFETY AND WARNING... 3 CONNECTION 3 INSTALLATION.. 4 ORDERING CODE 4 TROUBLE SHOOTING 4
Doc.Ref.No.:m92E/om/101 INDEX APPLICATION EXAMPLE 1 SPECIFICATION 2 SAFETY AND WARNING... 3 CONNECTION 3 INSTALLATION.. 4 ORDERING CODE 4 TROUBLE SHOOTING 4 ISOLATED CONVERTER 9000C SERIES 9000C Series
More informationMP-2000 Dual Channel LVDT/RVDT Readout/Controller
Large backlit dual channel display Menu driven setup and calibration 100 to 240 VAC line powered MIN, MAX, TIR, A+B and A-B functions 2.5, 3.3, 5 and 10kHz selectable excitation Analog and RS232 outputs
More informationE101 - Strain Gauge Transducer Display Module. Contents
E101 - Strain Gauge Transducer Display Module Contents Torque Transducer Display Interface: TSE3249R Strain Gauge Transducer Display Interface [E101] Operating Guide: TSE2097V (Includes Introduction, Description
More informationInstruction Manual. Instrument Amplifier HE 017
Instruction Manual Instrument Amplifier HE 017 List of contents INSTRUCTION MANUAL: HE 017 Date: 20.4.99 Art.-No.: 320999 S General Safety Instructions.......................................... S 1 General
More informationProcess & Temperature Digital Panel Meter
Process & Temperature Digital Panel Meter TRIDENT PD765 4-20 ma, ± 10 V, TC & RTD Inputs NEMA 4X, IP65 Front Shallow Depth Case 3.6" Behind Panel Universal Power Supply 85-265 VAC Two Relays Option with
More informationRXTH DUAL ROOM SENSOR / SWITCH
DUAL ROOM SENSOR / SWITCH FOR TEMPERATURE AND RELATIVE HUMIDITY Mounting and operating instructions Table of contents SAFETY AND PRECAUTIONS 3 PRODUCT DESCRIPTION 4 ARTICLE CODES 4 INTENDED AREA OF USE
More informationPRODIS. PD-ADC Digital Process Meter for analog Sensors. Digital Process Meters. Datasheet
Digital Process Meters Digital Process Meter for analog Sensors Datasheet Copyright ASM GmbH Am Bleichbach 18-24 85452 Moosinning Germany The information presented in this data sheet does not form part
More informationTemperature, Process &
Temperature, Process & 150 For Temp. Units 1/32 DIN meter 195 with 2 control outputs User Friendly, Simple to Configure High Quality i/32 i/16 i/8 Extended 5-Year Warranty Powerful Features Free Software,
More informationTOXALERT MODEL AIR 2000
TOXALERT MODEL AIR 2000 NOTE: Toxalert s Model GVU-CO 2 Sensor is the same as the Air2000R. Microprocessor-based, Infrared Environmental CO 2 Sensor OPERATOR S MANUAL TOXALERT TM INTERNATIONAL INC. P.O.
More informationJUMO Quantum PID100/PID200/PID300
Data sheet 702020 Page 1/12 JUMO Quantum PID100/PID200/PID300 Universal PID Controller Series Brief description The Quantum series is available in the three DIN formats 48 mm x 48 mm, 48 mm x 96 mm, and
More information100mm Process Indicator Recorder
Data Sheet SS/_3 100mm Process Indicator Recorder One or two pen continuous line 100mm recorder universal input for thermocouple, RTD, mv, ma and V Clear, 5-digit LED display high visibility, wide viewing
More informationPOSITION MONITOR USERS MANUAL POM-M2 / POM-M3. Content
POM-M2 POM-M3 POSITION MONITOR USERS MANUAL Content 1 TECHNICAL SPECIFICATION... 2 2 DESCRIPTION... 2 3 HANDLING... 3 3.1 Calibration... 3 3.2 Limit setting... 3 4 CONNECTION... 4 4.1 K1 Power supply...
More informationPanel Indicators. NEW 4~20mA Panel Display. Process Indicators INTECH INSTRUMENTS.
The LPI-LCD-6-4~20mA panel display is ideal for displaying a variety of process variables, and is easy to scale to your required engineering units. LPI-LCD-6 4~20mA Panel Display. Loop powered. Loop powered
More informationATR121 Controller with Dual Setpoint
ATR121 Controller with Dual Setpoint Food industry Ovens/furnaces Refrigeration Sterilizers Environmental chambers Safety units Injection moulding Driers General Specifications Dimensions Supply Voltage
More informationTPE 1464 Series Pressure Transducer
TPE 1464 Series Pressure Transducer Description The KMC TPE 1464 series of pressure transducers incorporate a gauge pressure transmitter featuring low hysteresis, excellent repeatability, and longterm
More informationPowerLogic power-monitoring units. PM1000 series power meter. Technical data sheet
PowerLogic power-monitoring units power meter Technical data sheet 2011 Basic energy meters Functions and characteristics PE86261 PE86260 PowerLogic PM1000 power meter. The PowerLogic power meters are
More informationElectronic Preset Counter with 2 Presets and Print interface. NE213 Prog Features
Electronic Preset Counter with 2 Presets and Print interface NE21 Prog. 09 Features Order designation Order no. Interface RS22 Models Connection Functions LED-preset counter with 2 presets Batch counter
More informationBasic Temperature and Limit Controllers. Provide Economical Solution for a Wide Range of Applications SPECIFICATION SHEET
SPECIFICATION SHEET Basic Temperature and Limit Controllers Basic Temperature and Limit Controllers Provide Economical Solution for a Wide Range of Applications The basic and limit microprocessor-based
More information/8 DIN Motorized Valve Controller
Data Sheet SS/_5 Boundless motorized valve controller no need for slidewire feedback; improves reliability Two sealed 5A control relays suitable for direct connection to the valve, reducing installation
More informationModular Panel Meter Series EDM 35
Modular Panel Meter Series EDM 35 CONTENTS Page 1. Introduction 2 1.1 Getting Started 2 1.2 Overall Description 3 1.3 Features 3 1.4 Block Schematic 4 2. Unit Description 4 2.1 Modules 4 2.2 Main Unit
More informationTemperature/Process Controllers Manual
3200 SERIES Temperature/Process Controllers Manual The innovative range of 3200 controllers offer precision control of temperature and other process variables together with a host of advanced features
More informationEnergy Management Modular DC Energy analyzer Type VMU-E and VMU-X
Energy Management Modular DC Energy analyzer Type VMU-E and VMU-X Modular solution based on the combination of two units: VMU-E analysis unit and VMU-X universal power supply and RS485 communication unit.
More informationDT1102 V (PS) Fully Configurable Galvanic Isolator. Operating Instructions
(PS) Fully Configurable Galvanic Isolator Operating Instructions Contents 1. About this document...4 1.1. Function... 4 1.2. Target group... 4 1.3. Symbolism used... 4 2. For your safety...5 2.1. Authorized
More information- SELF-TUNING PID ALGORITHM - INTUITIVE COLOR DISPLAY WITH TEXT MESSAGING - UNIVERSAL PROCESS AND TC/RTD INPUTS - MULTI- FUNCTION RAMP- DWELL/PROCESS
ELK. ETK COMPACT BASIC CONTROL - SELF-TUNING PID ALGORITHM - INTUITIVE COLOR DISPLAY WITH TEXT MESSAGING - UNIVERSAL PROCESS AND TC/RTD INPUTS - MULTI- FUNCTION RAMP- DWELL/PROCESS TIMER - SOFT START OUTPUT
More informationNEUROLOGIC RESEARCH CORPORATION MODEL 2500
NEUROLOGIC RESEARCH CORPORATION MODEL 2500 NETWORK HUMISTAT Compact, self-contained dehumidifier controller. 0.5 degrees C accuracy typical. RH sensor is digitally calibrated for 2% accuracy. Open communication
More informationNOW A PRODUCT! 1/4 DIN Auto/Manual Station. The Interface Solution Experts. The Interface Solution Experts. PS532 V6 March 2017
NOW A 5 3 2 The Interface Solution Experts PRODUCT! 5 3 2 1/4 DIN Auto/Manual Station The Interface Solution Experts PS532 V6 March 2017 GENERAL DESCRIPTION The 532 Auto/Manual Station ensures the integrity
More informationDigital Frequency Divider INSTRUCTION MANUAL CONTENTS. 1. Working Principle Installation Setting Up Technical Data 4.
Digital Frequency Divider INSTRUCTION MANUAL CONTENTS 1. Working Principle 2 2. Installation 2 3. Setting Up 3 4. Technical Data 4 Code: 189/1a 1 WORKING PRINCIPLE The DFD has been designed to generate
More informationMRC 7000 Proven Recording Reliability that Became the Industry Standard!
Data Sheet Recorder//Profiler DESCRIPTION The MRC7000 Recorder/ is a microprocessor based circular chart instrument capable of measuring, displaying, recording and controlling up to two process variables
More informationMeasurement Systems Datascan Installation and User Guide
Measurement Systems Datascan Installation and User Guide Supplied By Contents Contents 1. INTRODUCTION... 1 1.1 GENERAL... 1 1.2 DATASCAN MODULE RANGE... 1 1.2.1 Measurement Processors... 1 1.2.2 Analog
More informationUser s Guide DP20. Economical Multisignal Meter for Process, Temperatures and Electrical signals. Shop online at omega.com
TM User s Guide Shop online at omega.com e-mail: info@omega.com For latest product manuals: www.omegamanual.info DP20 Economical Multisignal Meter for Process, Temperatures and Electrical signals U.S.A.
More informationGUIDE PROGRAMMABLE PANEL METER M905
USER S GUIDE PROGRAMMABLE PANEL METER M905 Please read instructions carefully. 30727265 03/2018 Force Torque Pressure Acceleration - Standard Sensors and Custom Specials! MEAS France SAS, a TE Connectivity
More informationDigital Panel Meters
Digital Panel Meters For, Process, Voltage and Current DP63000 Starts at 81 DP63000B-E, 90, Thermocouple Inputs RTD Inputs Programmable Offset Selectable F or C with 1 or 0.1 Degree Resolution 3 Selectable
More informationFEMA ELECTRÓNICA. Panel meter for process signals in ma and Vdc. Accepts both active and passive
Panel Meters Series M40 Panel meter 96x48mm FEMA ELECTRÓNICA Model M40-P for process signals ( ±20mA and ±10Vdc) Panel meter for process signals in ma and Vdc. Accepts both active and passive signals,
More informationBA505C 2-wire 4/20mA manual setpoint station Issue 6
BA505C 2-wire 4/20mA manual setpoint station Issue 6 Issue: 6 3 rd December 2010 2 CONTENTS 1. Description 2. Operation 3. Electrical Systems Design 3.1 4/20mA loop 3.2 Optional Backlights 3.2.1 Separately
More informationSensor for car parks and tunnels
Page 1 Sep. 2017 system with exchangeable sensor element including digital value processing, temperature compensation and selfmonitoring algorithm for the continuous sensing and control of the ambient
More informationStrain Gage Measuring Amplifier GSV-1
Strain Gage Measuring Amplifier GSV-1 Tel 03302 559 282, Fax: 03302 559 141, info@me-systeme.de, www.me-systeme.de 1 Strain Gage Measuring Amplifier GSV-1 Description...3 Models...4 Technical Data...5
More informationPanel Meters Series M40 Model M40-A Amplicon.co m IT and Instrumentation for industry
Panel Meters Series M40 Panel meter 96x48mm FEMA ELECTRÓNICA Model M40-A TrueRMS AC Voltages TrueRMS AC Currents Panel meter for TrueRMS measures of AC voltages and AC currents. Measure category in CAT-III
More informationRhino Buffer Module PSM24-BFM600S. Operating Instructions
Rhino Buffer Module PSM24-BFM600S Operating Instructions RHINO BUFFER MODULE PSM24-BFM600S Description The PSM24-BFM600S Buffer Module will hold the output voltage of a 24 VDC power supply after brownouts
More informationTable of Contents. Introduction... 2 Description...2 Specifications...3 Installation.. 5 Calibration.. 6 General Maintenance...7
User's Manual: Series 330I Model 330I DC-Powered Three-Way Isolator Table of Contents Page Introduction... 2 Description....2 Specifications....3 Installation.. 5 Calibration.. 6 General Maintenance...7
More informationDS 96/48 PK. Digital indicator. Manual 42/33-90 EN Rev. 00 DIM
DS 96/48 PK Digital indicator Manual 42/33-90 EN Rev. 00 A1 A2 DIM E DS 96/48 PK Digital Indicator Manual Document No. 42/33-90 EN Edition 06.01 Revision 00 Manufacturer: ABB Automation Products GmbH Höseler
More informationTemperature Measurement
Copyright 1999-2002. All rights reserved. Web design by Sullivan Creative -1000 to +3500 and -10000 to +35000 Count Thermocouple, RTD, and Thermistor Temperature Measurement in C or F without Recalibration
More informationCHAPTER 1. Introduction Introduction 3
Technical & User Manual Weight Indicator: SMIT-3015 Manufactured By: Samyak Instrumentation Pvt.Ltd. F-4, Memnagar Complex, Opp.Petrol Pump, Memnagar Village, Ahmedabad, India-380052. Phone: +91-79-27495500/5600,
More informationBasic Temperature and Limit Controllers
Basic Temperature and Limit Controllers Basic Temperature and Limit Controller Provide Economical Solution for a Wide Range of Applications The basic and limit microprocessor-based controllers from Watlow
More informationMODCELL 2050R Single Loop Controllers
Isolated universal process and remote set-point input Four internal set-points No jumpers required to define instrument parameters Ratio/bias on process and remote set-point Totalizer Ramp/soak profile
More informationController module. Brief description. Features. Block structure. Page 1/7. Data Sheet
JUMO GmbH & Co. KG Delivery address:mackenrodtstraße 14, 36039 Fulda, Germany Postal address: 36035 Fulda, Germany Phone: +49 661 6003-0 Fax: +49 661 6003-607 E-mail: mail@jumo.net Internet: www.jumo.net
More information