SPD4tel & SPD4telkit. User Manual Manuel d Installation

Size: px
Start display at page:

Download "SPD4tel & SPD4telkit. User Manual Manuel d Installation"

Transcription

1 SPD4tel & SPD4telkit User Manual Manuel d Installation s

2 Total Home Surge Protection SPD4tel & SPD4telkit Surge Protection for Telephone or Modem Connected Electronics User Manual - USA (English) Features and Benefits UL listed Hardwired Modem/Fax/DSL protection Easy to install Exceptionally fast response time Low insertion loss Available with or without enclosure 5-Year product warranty* The Siemens SPD4tel is a 2 pair, hardwired surge protector for telephone, DSL or modem connected electronics in residential and light commercial applications. The SPD4tel protects against electrical power surges that can enter through the main telephone connection and is equipped with a failshort device to permanently ground the telephone line in the event of a power cross. The SPD4tel is designed for indoor applications or can be mounted inside another weatherproof enclosure for outdoor mounting applications. The SPD4telkit includes the SPD4tel plus a weatherproof enclosure to facilitate indoor or outdoor applications. The enclosure is molded of temperature and humidity resistant thermoplastic to resist cracking and discoloration. The cover can be secured with a tie wrap or similar locking device. 1 For total home protection please use SPD4home to protect your incoming AC Power lines and SPD4coax to protect your coaxial connections. Technical Specifications AC SURGE PROTECTION Catastrophic Surge Circuit Spike Capacity Let Through Voltage Overcurrent Protection Response Time Environmentally Sealed AGENCY APPROVALS & WARRANTY UL/cUL Listings Meets Telcordia (formallly Bellcore) GR-974-CORE Requirements for Telecommunications Line Protectors 200 Amps <270 V <1 nanosecond 497A Product Warranty 5 Years CATALOG NUMBER SPD4tel 2 pair protection module SPD4telkit 2 pair protection module 1 Weatherproof Enclosure UL Model No. - SATH2 * See for warranty details.

3 Installation Instructions: DO NOT INSTALL DURING ACTIVE STORM CONDITIONS. This device can be used indoor (SPD4tel), or outdoor when installed in weatherproof housing(spd4telkit). Failure to follow installation instructions can result in personal injury and/or equipment damage not covered by warranty. SPD4tel For indoor use: SPD4tel protects 2 pairs (1 pair per protector module) and is intended for indoor use only, without additional housing. Attach securely to mounting surface. Install ground wire, and if applicable, service shield, under top center nut of mounting bracket and tighten nut securely. Connect one pair (tip and ring) under the bottom nut on each protector module, tip on one post, ring on the other. Connect the customer wiring, tip and ring, under the top nut on the same protector module (protector is wired in parallel) Check all wiring for loose connections and shorting or broken wires. SPD4telkit For outdoor use: Mount weatherproof housing securely to flat surface. Conductors will enter and exit from the flexible grommet located at bottom of enclosure. Follow instruction above for SPD4tel connections. Secure enclosure with tie wrap or similar locking device. The SPD4telkit is a Parallel Device. Telco Side Cable Washers Ground Clip Customer Side Cable washers Siemens Industry, Inc Triangle Parkway Norcross, GA info.us@siemens.com 2

4 Total Home Surge Protection SPD4tel & SPD4telkit Surge Protection for Telephone or Modem Connected Electronics User Manual - Canada (English / Anglais) Features and Benefits cul listed Hardwired Modem/Fax/DSL protection Easy to install Exceptionally fast response time Low insertion loss Available with or without enclosure 5-Year product warranty* The Siemens SPD4tel is a 2 pair, hardwired surge protector for telephone, DSL or modem connected electronics in residential and light commercial applications. The SPD4tel protects against electrical power surges that can enter through the main telephone connection and is equipped with a failshort device to permanently ground the telephone line in the event of a power cross. The SPD4tel is designed for indoor applications or can be mounted inside another weatherproof enclosure for outdoor mounting applications. The SPD4telkit includes the SPD4tel plus a weatherproof enclosure to facilitate indoor or outdoor applications. The enclosure is molded of temperature and humidity resistant thermoplastic to resist cracking and discoloration. The cover can be secured with a tie wrap or similar locking device. 3 For total home protection please use SPD4home to protect your incoming AC Power lines and SPD4coax to protect your coaxial connections. Technical Specifications AC SURGE PROTECTION Catastrophic Surge Circuit Spike Capacity Let Through Voltage Overcurrent Protection Response Time Environmentally Sealed AGENCY APPROVALS & WARRANTY UL/cUL Listings Meets Telcordia (formallly Bellcore) GR-974-CORE Requirements for Telecommunications Line Protectors 200 Amps <270 V <1 nanosecond 497A Product Warranty 5 Years CATALOG NUMBER SPD4tel 2 pair protection module SPD4telkit 2 pair protection module 1 Weatherproof Enclosure UL Model No. - SATH2 * See for warranty details.

5 Installation Instructions: DO NOT INSTALL DURING ACTIVE STORM CONDITIONS. This device can be used indoor (SPD4tel), or outdoor when installed in weatherproof housing(spd4telkit). Failure to follow installation instructions can result in personal injury and/or equipment damage not covered by warranty. SPD4tel For indoor use: SPD4tel protects 2 pairs (1 pair per protector module) and is intended for indoor use only, without additional housing. Attach securely to mounting surface. Install ground wire, and if applicable, service shield, under top center nut of mounting bracket and tighten nut securely. Connect one pair (tip and ring) under the bottom nut on each protector module, tip on one post, ring on the other. Connect the customer wiring, tip and ring, under the top nut on the same protector module (protector is wired in parallel) Check all wiring for loose connections and shorting or broken wires. SPD4telkit For outdoor use: Mount weatherproof housing securely to flat surface. Conductors will enter and exit from the flexible grommet located at bottom of enclosure. Follow instruction above for SPD4tel connections. Secure enclosure with tie wrap or similar locking device. The SPD4telkit is a Parallel Device. Telco Side Cable Washers Ground Clip Customer Side Cable washers Siemens Canada Limited 2 Kenview Boulevard Brampton, Ontario L6T 5E4, Canada SPD Hotline : info@purgethesurge.ca 4

6 Manuel d installation - Canada (Français/ French) Limiteur général de surtension SPD4tel & SPD4telkit Protège le téléphone ou appareils électroniques branchés à un modem contre les surtensions Caractéristiques et avantages Homologation cul Protection câblée pour modem/télécopieur/ligne numérique Facile à installer Temps de réponse exceptionnellement rapide Affaiblissement d insertion peu important Avec ou sans boîtier Produit garanti 5 ans* Le suppresseur de surtensions SPD4tel câblé à deux paires de Siemens est destiné à la protection d appareillages électroniques pour la maison et les petites applications commerciales connectés par téléphone, ligne numérique ou modem. Le SPD4tel protège contre les surtensions qui peuvent provenir du raccordement téléphonique principal. Il comporte une sécurité intégrée qui met à la terre en permanence la ligne téléphonique, en cas d inversion de polarité. Conçu pour les applications intérieures, le SPD4tel peut aussi être installé à l extérieur, dans un boîtier étanche. L ensemble SPD4telkit comprend le suppresseur de surtensions SPD4tel et un boîtier étanche, afin de faciliter l installation à l intérieur comme à l extérieur. Fait de thermoplastique résistant aux écarts de température et à l humidité, le boîtier résiste ainsi au fendillement et à la décoloration. Son couvercle peut être fixé à l aide d une attache autobloquante ou d un dispositif de blocage semblable. 5 Pour assurer la sécurité complète d une maison, ajoutez le dispositif SPD4home, qui protège les circuits d alimentation c.a., ainsi que l ensemble SPD4coax, qui protège les liaisons par câble coaxial. Technical Specifications AC SURGE PROTECTION Catastrophic Surge Circuit Données techniques Spike Capacity Let Through Voltage Overcurrent Protection Response Time Environmentally Sealed AGENCY APPROVALS & WARRANTY UL/cUL Listings Meets Telcordia (formallly Bellcore) GR-974-CORE Requirements for Telecommunications Line Protectors Product Warranty CATALOG NUMBER SPD4tel SPD4telkit 200 Amps <270 V <1 nanosecond 497A 5 Years 2 pair protection module 2 pair protection module 1 Weatherproof Enclosure UL Model No. - SATH2 * Voir le site pour les modalités de la garantie.

7 Installation Instructions: NE PAS INSTALLER PENDANT UN ORAGE. Le dispositif SPD4tel peut être utilisé à l intérieur comme à l extérieur, s il est placé dans un boîtier étanche (SPD4telkit). Veuillez suivre les directives d installation, à défaut de quoi, vous vous exposez à des blessures et/ou risquez de causer des dommages à l équipement non couverts par la garantie. SPD4tel Pour usage intérieur : Le dispositif SPD4tel, qui protège deux paires de câbles (une par module de protection), est destiné à un usage intérieur seulement, à moins de le poser dans un boîtier additionnel. Le fixer solidement à la surface de montage. Installer le câble de mise à la terre et, s il y a lieu, le bouclier, au moyen de l écrou central supérieur du support de fixation, puis serrer l écrou fermement. Raccorder une paire (tête et nuque) sous l écrou inférieur de chaque module de protection, la tête sur une borne, la nuque sur l autre. Raccorder le câblage client, tête et nuque, sous l écrou supérieur du même module de protection (le module est câblé en parallèle). Vérifier tout le câblage pour vous assurer qu il est bien raccordé et qu il n y a pas de connexion lâche, de fil endommagé ou de risque de court-circuit. SPD4telkit Pour usage extérieur : Fixer solidement le boîtier étanche sur une surface plane. Les conducteurs entreront et sortiront par le passe-câble souple situé à la base du boîtier. Suivre les directives ci-dessus pour raccorder le SPD4tel. Bloquer le couvercle du boîtier avec une attache autobloquante ou un moyen de fixation semblable. L ensemble SPD4telkit est un dispositif parallèle. Telco Side Cable Washers Ground Clip Customer Side Cable washers Siemens Canada Limitée 2 Kenview Boulevard Brampton, Ontario L6T 5E4, Canada SPD Hotline : info@purgethesurge.ca 6

8 s #8036

Residential SPD Catalogue. Surge Protective Devices.

Residential SPD Catalogue. Surge Protective Devices. Residential SPD Catalogue Surge Protective Devices Total Home Surge Protection Surge Protective Devices Stop surges before they get into your home by installing Siemens 4home Surge Protection SPD4home

More information

Surge Protection Devices (SPD)

Surge Protection Devices (SPD) TPS3 03 TPS3 03 is a UL 1449 3rd Edition, cul 50 ka Type 1 (Type cul) compact Surge Protective Device. For cul applications, the TPS3 03 can be used as a secondary surge or lighting arrestor alternative

More information

ControlLogix Redundant Power Supply Chassis Adapter Module

ControlLogix Redundant Power Supply Chassis Adapter Module Installation Instructions ControlLogix Redundant Power Supply Chassis Adapter Module Catalog Number 1756-PSCA Use this publication as a guide when installing the ControlLogix 1756-PSCA chassis adapter

More information

FlexArmor 24V dc Sinking Input Modules

FlexArmor 24V dc Sinking Input Modules Installation Instructions FlexArmor 24V dc Sinking Input Modules Catalog Number 1798-IB4 & 1798-IB8 42638 The FlexArmor I/O modules (Cat. No. 1798-IB4 & 1798-IB8) mount in a FlexArmor Baseplate. Use compatible

More information

This manual provides information on the Extron MDA 4V EQ video distribution amplifier and discusses how to install and operate them.

This manual provides information on the Extron MDA 4V EQ video distribution amplifier and discusses how to install and operate them. MDA V EQ USER GUIDE Introduction About this Manual This manual provides information on the Extron MDA V EQ video distribution amplifier and discusses how to install and operate them. About the MDA V EQ

More information

LVB-2 INSTRUCTION SHEET. Leakage Current Verification Box

LVB-2 INSTRUCTION SHEET. Leakage Current Verification Box LVB-2 INSTRUCTION SHEET Leakage Current Verification Box V 1.02 1.2018 DECLARATION OF CONFORMITY Manufacturer: Address: Product Name: Model Number: Associated Research, Inc. 13860 W. Laurel Dr. Lake Forest,

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS 6400 Single and Multidock INSTALLATION INSTRUCTIONS " " " " " " " " " " " " " " " " " " " " " " " " " " " " PN: 962-020-004 Revision A September 1998 " NOTICE The information contained herein is proprietary

More information

Cellular Select Gate Installer Guide Models SG2CL, SG3DMCL, SG3DMRCL

Cellular Select Gate Installer Guide Models SG2CL, SG3DMCL, SG3DMRCL Cellular Select Gate Installer Guide Models SG2CL, SG3DMCL, SG3DMRCL NOTE: This Product Requires GSM Carrier/SIM with Active Talk (Voice) and Text (SMS) Services For Operation Hialeah, FL 33016 www.selectses.com

More information

VI 021 S-DIAS VARAN Control Module

VI 021 S-DIAS VARAN Control Module VI 021 S-DIAS VARAN Control Module Date of creation: 11.06.2013 Version date: 18.10.2017 Article number: 20-003-021-E Publisher: SIGMATEK GmbH & Co KG A-5112 Lamprechtshausen Tel.: +43/6274/4321 Fax: +43/s6274/4321-18

More information

1 PORT HARDENED SERIAL SERVER

1 PORT HARDENED SERIAL SERVER QUICK START GUIDE LES421A 1 PORT HARDENED SERIAL SERVER 24/7 TECHNICAL SUPPORT AT 877.877.2269 OR VISIT BLACKBOX.COM STEP 1 - Check for All Required Hardware 1-Port Hardened Serial Server This Quick Start

More information

User guide. Bluetooth Keyboard BKB10

User guide. Bluetooth Keyboard BKB10 User guide Bluetooth Keyboard BKB10 Contents Basics...3 Overview... 3 Charging the keyboard... 4 Turning on the keyboard... 5 Getting started... 6 Setting up the keyboard... 6 Support on the web...6 Legal

More information

400 Series 460 Surge Protective Device Installation, Operation and Maintenance Manual

400 Series 460 Surge Protective Device Installation, Operation and Maintenance Manual 400 Series 460 Surge Protective Device Installation, Operation and Maintenance Manual Installation, Operation and Maintenance Manual IO-70104 Rev 1, 1/2014 EMERSON NETWORK POWER SURGE PROTECTIVE DEVICE

More information

300 Series 330/320 Surge Protective Device Installation, Operation and Maintenance Manual

300 Series 330/320 Surge Protective Device Installation, Operation and Maintenance Manual Power Switching & Controls For Business-Critical Continuity 300 Series 330/320 Surge Protective Device Installation, Operation and Maintenance Manual Installation, Operation and Maintenance Manual EMERSON

More information

EcoView 8 DO Module Installation and Commissioning

EcoView 8 DO Module Installation and Commissioning Document No. 129-565 EcoView 8 DO Module Installation and Commissioning This document covers the installation and commissioning of the EcoView 8 DO Module. See the following documents for installation

More information

AgileMesh Node Configuration Guide

AgileMesh Node Configuration Guide AgileMesh Node Configuration Guide AV1520G2 AV2010G2 Node Software Version 2.X September 7, 2012 Document Rev 1.7 Table of Contents Table of Contents...2 FCC Statement...3 Industry Canada Statement...4

More information

MCG Surge Protection

MCG Surge Protection 299-700-33B 299-700-33A MCG Surge Protection Installation/Operating Instructions for MCG 500 Series Important Warranty Information MCG surge protectors are designed to work at specific voltages and configurations,

More information

ArmorBlock MaXum 4 Output Module Series B

ArmorBlock MaXum 4 Output Module Series B Installation Instructions ArmorBlock MaXum 4 Output Module Series B (Cat. No. 1792D-0B4D) 41525 This ArmorBlock MaXum I/O module (Cat. No. 1792D-0B4D) is a stand-alone 24V dc I/O product which communicates

More information

FX Supervisory Controller Wireless TEC Option Card Installation Instructions

FX Supervisory Controller Wireless TEC Option Card Installation Instructions Installation Instructions Wireless TEC Option Card Date August 29, 2014 FX Supervisory Controller Wireless TEC Option Card Installation Instructions Applications IMPORTANT: The FX Supervisory Controller

More information

Headend Unit (HEU) Quick Installation Sheet

Headend Unit (HEU) Quick Installation Sheet Headend Unit (HEU) Quick Installation Sheet CMA-267-AEN GENERAL INFORMATION. The HEU chassis is supplied empty and only includes the factoryassembled fan module (FAM). All other modules are ordered separately

More information

OUTDOOR WIRELESS ACCESS POINT

OUTDOOR WIRELESS ACCESS POINT AN-700-AP-O-AC OUTDOOR WIRELESS ACCESS POINT Federal Communication Commission Interference Statement This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant

More information

Surge Protective Devices. Installation & Operation Manual. Model 570/575. Model 575 Model 570 Model 565 Model 560. Model 560/565

Surge Protective Devices. Installation & Operation Manual. Model 570/575. Model 575 Model 570 Model 565 Model 560. Model 560/565 Surge Protective Devices Installation & Operation Manual Model 570/575 Model 560/565 Model 575 Model 570 Model 565 Model 560 Installation, Operation and Maintenance Manual 2 ASCO SURGE PROTECTIVE DEVICE

More information

VLANs. Commutation LAN et Wireless Chapitre 3

VLANs. Commutation LAN et Wireless Chapitre 3 VLANs Commutation LAN et Wireless Chapitre 3 ITE I Chapter 6 2006 Cisco Systems, Inc. All rights reserved. Cisco Public 1 Objectifs Expliquer le rôle des VLANs dans un réseau convergent. Expliquer le rôle

More information

PS 101 S-DIAS Power Supply Module

PS 101 S-DIAS Power Supply Module PS 101 S-DIAS Power Supply Module Date of creation: 03.12.2013 Version date: 20.09.2018 Article number: 20-003-101-E Publisher: SIGMATEK GmbH & Co KG A-5112 Lamprechtshausen Tel.: +43/6274/4321 Fax: +43/6274/4321-18

More information

Quick Start. AC1200 WiFi Range Extender Model EX6150

Quick Start. AC1200 WiFi Range Extender Model EX6150 Quick Start AC1200 WiFi Range Extender Model EX6150 Getting Started The NETGEAR WiFi Range Extender increases the distance of a WiFi network by boosting the existing WiFi signal and enhancing the overall

More information

SolarEdge Quick Installation Guide North America

SolarEdge Quick Installation Guide North America SolarEdge Quick Installation Guide North America : MAN01000251.8 For full installation and safety details, you must refer to the SolarEdge Installation Guide. Make sure you read, fully understand and follow

More information

Canada s Energy Future:

Canada s Energy Future: Page 1 of 9 1DWLRQDO (QHUJ\ %RDUG 2IILFH QDWLRQDO GH OҋpQHUJLH Canada s Energy Future: ENERGY SUPPLY AND DEMAND PROJECTIONS TO 2035 Appendices AN ENERGY MARKET ASSESSMENT NOVEMBER 2011 Page 2 of 9 Canada

More information

SURGE PROTECTOR DEVICE INSTALLATION MANUAL

SURGE PROTECTOR DEVICE INSTALLATION MANUAL 14000 Burn Rd Arlington, WA 98223 USA Ph (425)374-9060 www.midnitesolar.com SURGE PROTECTOR DEVICE INSTALLATION MANUAL The MidNite Solar Surge Protector Device (MNSPD) is a Type 1 device, designed for

More information

VARAN Splitter PROFINET VSP 042

VARAN Splitter PROFINET VSP 042 VARAN SPLITTER PROFINET VSP 042 VARAN Splitter PROFINET VSP 042 With its 3 VARAN Out ports, the VARAN VSP 042 splitter module allows a VARAN bus system to be configured in a tree structure. At the Ethernet

More information

RO 051 S-DIAS Relay Output Module

RO 051 S-DIAS Relay Output Module RO 051 S-DIAS Relay Output Module Date of creation: 10.08.2015 Version date: 18.10.2017 Article number: 20-064-051-E Publisher: SIGMATEK GmbH & Co KG A-5112 Lamprechtshausen Tel.: +43/6274/4321 Fax: +43/6274/4321-18

More information

1769 Compact I/O Communication Bus Expansion Cables

1769 Compact I/O Communication Bus Expansion Cables 1769 Compact I/O Communication Bus Expansion Cables (Cat. No. 1769-CRR1, 1769-CRR3, 1769-CLL1, 1769-CLL3, 1769-CRL1, 1769-CRL3) Installation Inside... For More Information... 2 Hazardous Location Considerations...

More information

ICA 012 S-DIAS Interface Module CAN

ICA 012 S-DIAS Interface Module CAN ICA 012 S-DIAS Interface Module CAN Date of creation: 06.09.2016 Version date: 25.06.2018 Article number: 20-102-012-E Publisher: SIGMATEK GmbH & Co KG A-5112 Lamprechtshausen Tel.: +43/6274/4321 Fax:

More information

SSI 021 S-DIAS Safety SSI Absolute Value Encoder

SSI 021 S-DIAS Safety SSI Absolute Value Encoder SSI 021 S-DIAS Safety SSI Absolute Value Encoder Date of creation: 25.02.2014 Version date: 18.10.2017 Article number: 20-894-021-E Publisher: SIGMATEK GmbH & Co KG A-5112 Lamprechtshausen Tel.: +43/6274/4321

More information

PC 521 Data Recording PC

PC 521 Data Recording PC PC 521 Data Recording PC Date of creation: 26.04.2018 Version date: 17.08.2018 Article number: 01-310-521-E Publisher: SIGMATEK GmbH & Co KG A-5112 Lamprechtshausen Tel.: +43/6274/4321 Fax: +43/6274/4321-18

More information

PC 400 Control Cabinet PC

PC 400 Control Cabinet PC PC 400 Control Cabinet PC Date of creation: 08.04.2015 Version date: 12.03.2018 Article number: 01-310-411-E Publisher: SIGMATEK GmbH & Co KG A-5112 Lamprechtshausen Tel.: +43/6274/4321 Fax: +43/6274/4321-18

More information

MicroLogix 1200 Isolated Relay Output Module

MicroLogix 1200 Isolated Relay Output Module Installation Instructions MicroLogix 1200 Isolated Relay Output Module (Catalog Number 1762-OX6I) Inside For More Information...2 Description...3 Installation...3 Mounting...5 System Assembly...7 Field

More information

ArmorBlock MaXum 8 Input / 8 Output Module Series B

ArmorBlock MaXum 8 Input / 8 Output Module Series B Installation Instructions ArmorBlock MaXum 8 Input / 8 Output Module Series B (Cat. No. 1792D-8BVT8D) I-0 O-0 I-1 O-1 I-2 O-2 I-3 O-3 I-4 I-5 O-5 O-4 I-6 O-6 I-7 O-7 Auxilary Power Logic Status Net/Mod

More information

Installation Instructions

Installation Instructions Installation Instructions MicroLogix 1762-IA8 120V ac Input Module Inside Description...3 Installation...4 Mounting...5 System Assembly...7 Field Wiring Connections...7 I/O Memory Mapping...10 Specifications...11

More information

INSTRUCTION MANUAL INSTRUCTION MANUAL

INSTRUCTION MANUAL INSTRUCTION MANUAL PACK MATERNITY INSTRUCTION MANUAL INSTRUCTION MANUAL Specially designed for deaf and hearing impaired people. All your products sent together are already connected to each other. 2 2 Summary : 4 : The

More information

Instruction Sheet PDS-SERIES SEQUENCED MULTI-MOUNT

Instruction Sheet PDS-SERIES SEQUENCED MULTI-MOUNT Instruction Sheet PDS-SERIES SEQUENCED MULTI-MOUNT S u Sta tu e s t no or Si e Se qu tpu Up Cq cc /Denc ompen l e ee owe te n g r Se Lo q c a CON TR I nu enl O i ti ce L ate Clo Com prsed om i f i se d

More information

Instruction Sheet. Proximity Series. Mounting Plate

Instruction Sheet. Proximity Series. Mounting Plate Instruction Sheet Proximity Series Mounting Plate THANK YOU Thank you for purchasing the Proximity Series Mounting Plate. Please read these instructions thoroughly before installing or assembling this

More information

About Transferring License Rights for. PL7 V4.5 and Unity Pro V2.3 SP1 Software

About Transferring License Rights for. PL7 V4.5 and Unity Pro V2.3 SP1 Software Page 1 of 38 Click here to access the English Cliquez ici pour accéder au Français Klicken Sie hier, um zum Deutschen zu gelangen Premete qui per accedere all' Italiano Pulse acquì para acceder al Español

More information

INDUSTRIAL OUTDOOR A/N WIRELESS ETHERNET

INDUSTRIAL OUTDOOR A/N WIRELESS ETHERNET QUICK START GUIDE INDUSTRIAL OUTDOOR 802.11A/N WIRELESS ETHERNET This manual serves the following GANZ Model Numbers: Thank you for purchasing the GWave from GANZ. This quick start guide is designed to

More information

Belkin Administrator Guide

Belkin Administrator Guide Section 1 - Introduction Belkin Administrator Guide Belkin Administrator Guide Products covered by this manual: Belkin Secure KVM, KM, and Windowing KVM Doc No: HDC10957 Rev: F Table of Contents Introduction...

More information

SE 051 S-DIAS Splitter Ethernet

SE 051 S-DIAS Splitter Ethernet SE 051 S-DIAS Splitter Ethernet Date of creation: 03.12.2014 Version date: 18.10.2017 Article number: 20-023-051-E Publisher: SIGMATEK GmbH & Co KG A-5112 Lamprechtshausen Tel.: +43/6274/4321 Fax : +43/6274/4321-18

More information

User guide. Stereo Bluetooth Headset SBH60

User guide. Stereo Bluetooth Headset SBH60 User guide Stereo Bluetooth Headset SBH60 Contents Introduction...3 Function overview...3 Hardware overview... 3 Basics...5 Charging the battery...5 Turning the headset on and off...5 Adjusting the volume...

More information

Oracle ZFS Storage Appliance Cabling Guide. For ZS3-x, 7x20 Controllers, and DE2-24, Sun Disk Shelves

Oracle ZFS Storage Appliance Cabling Guide. For ZS3-x, 7x20 Controllers, and DE2-24, Sun Disk Shelves Oracle ZFS Storage Appliance Cabling Guide For ZS3-x, 7x20 Controllers, and DE2-24, Sun Disk Shelves Part No: E53670-01 June 2014 Copyright 2009, 2014, Oracle and/or its affiliates. All rights reserved.

More information

ISE 021 S-DIAS Interface Module RS232 / RS485

ISE 021 S-DIAS Interface Module RS232 / RS485 ISE 021 S-DIAS Interface Module RS232 / RS485 Date of creation: 23.04.2014 Version date: 31.01.2018 Article number: 20-101-021-E Publisher: SIGMATEK GmbH & Co KG A-5112 Lamprechtshausen Tel.: +43/6274/4321

More information

Lumencor SPECTRA Light Engine Instruction Manual

Lumencor SPECTRA Light Engine Instruction Manual Lumencor SPECTRA Light Engine Instruction Manual Lumencor, Inc. 14964 NW Greenbrier Parkway, Beaverton, OR 97006 T 503.213.4269 F 503.536.6741 www.lumencor.com Emissions Certifications This equipment has

More information

1. Getting to know the gimbal

1. Getting to know the gimbal 1. Getting to know the gimbal Roll Motor Mounting Screw Containing Bracket Mode Button Joystick LED Light Power Button Shutter Button Thank you for choosing YI products 2. How to use the gimbal 1) Charging

More information

EPC-SKLU. Quick Reference Guide. Intel Core SoC Processor Fanless Box PC. Copyright Notice. 2 nd Ed 14 March Copyright 2018 ALL RIGHTS RESERVED.

EPC-SKLU. Quick Reference Guide. Intel Core SoC Processor Fanless Box PC. Copyright Notice. 2 nd Ed 14 March Copyright 2018 ALL RIGHTS RESERVED. Intel Core SoC Processor Fanless Box PC Quick Reference Guide 2 nd Ed 14 March 2018 Copyright Notice Copyright 2018 ALL RIGHTS RESERVED. Part No. E2017CAG0A1R FCC Statement THIS DEVICE COMPLIES WITH PART

More information

2201 Rack Chassis User Manual

2201 Rack Chassis User Manual 2201 Rack Chassis User Manual CAUTION! This product may contain a laser diode operating at a wavelength of 1300 nm - 1600 nm. Use of optical instruments (e.g., collimating optics) with this product may

More information

WASP Wireless Acceleration Sensor Puck USER MANUAL

WASP Wireless Acceleration Sensor Puck USER MANUAL WASP Wireless Acceleration Sensor Puck USER MANUAL VERSION 3.20 15/07/2016 WASP is a registered trademark owned by BossPac Engineering & Technology WASP is a PATENT PENDING technology owned by BossPac

More information

DEAKO SWITCH INSTALLATION GUIDE. Includes instructions for single-pole, 3-way, 4-way and dead-end 3-way wiring configurations for Deako Switches.

DEAKO SWITCH INSTALLATION GUIDE. Includes instructions for single-pole, 3-way, 4-way and dead-end 3-way wiring configurations for Deako Switches. DEAKO SWITCH INSTALLATION GUIDE Includes instructions for single-pole, -way, 4-way and dead-end -way wiring configurations for Deako Switches. DEAKO.COM BEFORE YOU GET STARTED This installation guide is

More information

Home Networking Solutions Using the HomePNA modem with Sony VAIO Computers

Home Networking Solutions Using the HomePNA modem with Sony VAIO Computers Home Networking Solutions Using the HomePNA modem with Sony VAIO Computers The information contained in this manual supercedes related information and instructions that may be contained in your VAIO Computer

More information

GETTING STARTED WITH IN-WALL RELAY SWITCH

GETTING STARTED WITH IN-WALL RELAY SWITCH GETTING STARTED WITH IN-WALL RELAY SWITCH This document is the property of Webee L.L.C. The data contained here, in whole or in part, may not be duplicated, used or disclosed outside the recipient for

More information

User guide. Stereo Bluetooth Headset SBH80

User guide. Stereo Bluetooth Headset SBH80 User guide Stereo Bluetooth Headset SBH80 Contents Introduction...3 Function overview...3 Hardware overview... 3 Basics...5 Charging the battery...5 Battery status... 5 Turning the headset on and off...5

More information

ControlLogix DC (10-30V) Isolated Output Module

ControlLogix DC (10-30V) Isolated Output Module Installation Instructions ControlLogix DC (10-30V) Isolated Output Module (Catalog Number 1756-OB16I) To: See page: Obtain a User Manual 1 Identify the Module Components 2 Prevent Electrostatic Discharge

More information

ArmorBlock MaXum Robot I/O Cable Base and Kempf Box Plate

ArmorBlock MaXum Robot I/O Cable Base and Kempf Box Plate Installation Instructions ArmorBlock MaXum Robot I/O Cable Base and Kempf Box Plate (Cat. No. 1792D-CB23 and -KPLT) CB23 KPLT 43338 43333 The 23mm ArmorBlock MaXum Robot Ι/Ο Cable Base mates with 4 or

More information

Installation Instructions RF5010 and RF5210

Installation Instructions RF5010 and RF5210 Installation Instructions RF5010 and RF5210 HES, Inc. 22630 N. 17th Ave. Phoenix, AZ 85027 800-626-7590 1 Product Description Dimensions Orientation Compatibility Access Control Systems Proximity Cards

More information

C-DIAS VARAN Control Module CIV x VARAN-In 1 x VARAN-Out (Optional Ethernet (VtE))

C-DIAS VARAN Control Module CIV x VARAN-In 1 x VARAN-Out (Optional Ethernet (VtE)) C-DIAS VARAN CONTROL MODULE CIV 512 C-DIAS VARAN Control Module CIV 512 1 x VARAN-In 1 x VARAN-Out (Optional Ethernet (VtE)) The C-DIAS CIV 512 module serves as the power supply and connection for decentralized

More information

MicroLogix 1762-OB16 Solid State 24V dc Source Output Module

MicroLogix 1762-OB16 Solid State 24V dc Source Output Module Installation Instructions MicroLogix 1762-OB16 Solid State 24V dc Source Output Module Inside Description...3 Installation...4 Mounting...5 System Assembly...7 Field Wiring Connections...7 I/O Memory Mapping...10

More information

Installation Instructions

Installation Instructions Installation Instructions MicroLogix 1762-IQ8 DC Input Module Inside Description...3 Installation...4 Mounting...5 System Assembly...7 Field Wiring Connections...7 I/O Memory Mapping...10 Specifications...11

More information

AMPAV40 INSTALLATION AND OPERATION MANUAL

AMPAV40 INSTALLATION AND OPERATION MANUAL INSTALLATION AND OPERATION MANUAL AMPAV40 ACTIVE THREE WAY STEREO SPEAKER SYSTEM IMPORTANT SAFETY INFORMATION PRÉCAUTIONS DURANT UTILISATION 1. Read these instructions. 2. Keep these instructions. 3. Heed

More information

EA_Gatekeeper model 2120

EA_Gatekeeper model 2120 EA_Gatekeeper model 2120 Installation instructions IL42-5037A General Within the EnergyAxis System, the EA_Gatekeeper is the intelligent interface between the EnergyAxis Management System (EA_MS) and the

More information

NetPoint Pro Family. Hardware Installation. Broadband Wireless Networking Solutions NetPoint Pro 6x2.4 (G2 and G2M) 2 nd Generation

NetPoint Pro Family. Hardware Installation. Broadband Wireless Networking Solutions NetPoint Pro 6x2.4 (G2 and G2M) 2 nd Generation NetPoint Pro Family Broadband Wireless Networking Solutions NetPoint Pro 6x2.4 (G2 and G2M) Hardware Installation 2 nd Generation This document contains information that is proprietary to Netronics Technologies

More information

FLEX Integra 2 Input/2 Protected Output Module

FLEX Integra 2 Input/2 Protected Output Module Installation Instructions FLEX Integra 2 Input/2 Protected Output Module (Cat. No. 1793-IB2XOB2P and -IB2XOB2PS) 41355 Module Installation This module mounts on a DIN rail. It connects to an adapter or

More information

INDUSTRIAL OUTDOOR A/N WIRELESS ETHERNET KIT

INDUSTRIAL OUTDOOR A/N WIRELESS ETHERNET KIT QUICK START GUIDE INDUSTRIAL OUTDOOR 802.11A/N WIRELESS ETHERNET KIT This manual serves the following ComNet Model Numbers: NWK1 NWK2 Thank you for purchasing NetWave from ComNet. This quick start guide

More information

FLEX Integra 4 Input Module

FLEX Integra 4 Input Module Installation Instructions FLEX Integra 4 Input Module (Cat. No. 1793-IB4 and -IB4S) 41355 Module Installation This module mounts on a DIN rail. It connects to an adapter or another FLEX I/O or Integra

More information

FLEX I/O EtherNet/IP Adapter Module

FLEX I/O EtherNet/IP Adapter Module Installation Instructions FLEX I/O EtherNet/IP Adapter Module Catalog Numbers 1794-AENT Use this manual as a guide to install the FLEX I/O EtherNet/IP Adapter Module. Note that this manual covers hardware

More information

Installation Notes TII Model 341 Protector

Installation Notes TII Model 341 Protector Installation Notes TII Model 341 Protector (ATT-IS PEC 32918) for MERLIN Communications System In Range Out of Building (IROB) Station Installation By Trained Technician Only WARNING: Failure to follow

More information

Home Control. Installation Guide TWO SWITCHES

Home Control. Installation Guide TWO SWITCHES Home Control Installation Guide TWO SWITCHES Welcome! Is your circuit 120V? This short installation guide will help you upgrade your home with Brilliant. It is important that you first review all of the

More information

AURA Light Engine Instruction Manual

AURA Light Engine Instruction Manual AURA Light Engine Instruction Manual Lumencor, Inc. Document Number 57-10007, Rev. A www.lumencor.com Regulatory Models Lumencor utilizes regulatory model names for all certified and CE marked products.

More information

ControlLogix DC ( V) Electronically Fused Output Module

ControlLogix DC ( V) Electronically Fused Output Module Installation Instructions ControlLogix DC (10-31.2V) Electronically Fused Output Module (Catalog Number 1756-OB16E) To: See page: Obtain a User Manual 1 Identify the Module Components 2 Prevent Electrostatic

More information

Oracle Dual Port QDR InfiniBand Adapter M3. Product Notes

Oracle Dual Port QDR InfiniBand Adapter M3. Product Notes Oracle Dual Port QDR InfiniBand Adapter M3 Product Notes Part No.: E40986-01 September 2013 Copyright 2013 Oracle and/or its affiliates. All rights reserved. This software and related documentation are

More information

Surge Protective Devices. Installation & Operation Manual. NEMA 12 (Steel) NEMA 1 (Non-Metallic) Model 350

Surge Protective Devices. Installation & Operation Manual. NEMA 12 (Steel) NEMA 1 (Non-Metallic) Model 350 Surge Protective Devices Installation & Operation Manual NEMA 12 (Steel) NEMA 1 (Non-Metallic) Model 50 ASCO SURGE PROTECTIVE DEVICE INSTALLATION, OPERATION AND MAINTENANCE MANUAL TABLE OF CONTENTS INSTALLATION

More information

SI 021 S-DIAS SSI Interface Module

SI 021 S-DIAS SSI Interface Module SI 021 S-DIAS SSI Interface Module Date of creation: 16.06.2014 Version date: 18.10.2017 Article number: 20-022-021-E Publisher: SIGMATEK GmbH & Co KG A-5112 Lamprechtshausen Tel.: +43/6274/4321 Fax: +43/6274/4321-18

More information

Product Overview EA6350 V3. Top view

Product Overview EA6350 V3. Top view Product Overview EA6350 V3 Top view Indicator light Stays on steadily while power is connected and following a successful Wi-Fi Protected Setup connection. Flashes or pulses slowly during bootup, during

More information

STO 081 S-DIAS Safety Digital Output Module

STO 081 S-DIAS Safety Digital Output Module STO 081 S-DIAS Safety Digital Output Module Date of creation: 18.12.2013 Version date: 20.09.2018 Article number: 20-892-081-E Publisher: SIGMATEK GmbH & Co KG A-5112 Lamprechtshausen Tel.: +43/6274/4321

More information

Installation Instructions. P/N Revision A April Single Dock. P/N Revision A

Installation Instructions. P/N Revision A April Single Dock. P/N Revision A nstallation nstructions P/N 96-00-00 Revision A April 1996 600 Single Dock P/N 96-00-00 Revision A tem# Description PN Qty 1. Power supply 851-09-001 ref.*. cable, dock to PC-AT or 16-787-00x ref.* laptop.

More information

MLC Plus 50/100/200 Series Setup Guide

MLC Plus 50/100/200 Series Setup Guide MLC Plus 50/100/200 Series Setup Guide VIDEO MLC Plus 50 LAPTOP VIDEO MLC Plus 100 VGA DOC CAM The MLC Plus 50/100/200 Series MediaLink Controllers with IP Link Pro integrate Ethernet connection into AV

More information

MIRA Light Engine Instruction Manual

MIRA Light Engine Instruction Manual MIRA Light Engine Instruction Manual Lumencor, Inc. Document Number 52-10028, Rev. B www.lumencor.com Regulatory Models Lumencor utilizes regulatory model names for all certified and CE marked products.

More information

Installation Instructions RF5010 and RF5210

Installation Instructions RF5010 and RF5210 Installation Instructions RF5010 and RF5210 HES, Inc. 2260 N. 17th Ave. Phoenix, AZ 85027 800-626-7590 1 Product Description Dimensions Orientation Compatibility Access Control Systems Proximity Cards

More information

Ultra Enterprise 6000/5000/4000 Systems Power Cord Installation

Ultra Enterprise 6000/5000/4000 Systems Power Cord Installation Ultra Enterprise 6000/5000/4000 Systems Power Cord Installation RevisiontoPowerCordInstallation Note This replaces Chapter 2, Cabling the System, in the Ultra Enterprise 6000/5000/4000 Systems Installation

More information

Internet Office 120V 600VA 300W Standby UPS, Ultra-Compact Desktop, USB

Internet Office 120V 600VA 300W Standby UPS, Ultra-Compact Desktop, USB Internet Office 120V 600VA 300W Standby UPS, Ultra-Compact Desktop, USB NUMÉRO DE MODÈLE: INTERNET600U Points principaux 600VA ultra-compact 120V standby UPS Maintains AC output during power failures 4

More information

Read me carefully before making your connections!

Read me carefully before making your connections! CROSS GAME USER GUIDE Read me carefully before making your connections! Warning: The CROSS GAME converter is compatible with most brands of keyboards and Gamer mice. However, we cannot guarantee 100% compatibility.

More information

READ ME FIRST QUICK INSTALL GUIDE. Wireless Controller XWC Includes: One: XWC-1000 Wireless Controller One: Rack Mount Kit One: Power Cord

READ ME FIRST QUICK INSTALL GUIDE. Wireless Controller XWC Includes: One: XWC-1000 Wireless Controller One: Rack Mount Kit One: Power Cord READ ME FIRST QUICK INSTALL GUIDE Wireless Controller XWC-1000 Includes: One: XWC-1000 Wireless Controller One: Rack Mount Kit One: Power Cord E E READ ME FIRST - COMPATIBILITY Your XWC-1000 Wireless Controller

More information

Surge Protective Devices. Installation & Operation Manual. Model 520. Model 515. Model 520 Model 515. Model 510. Model 510

Surge Protective Devices. Installation & Operation Manual. Model 520. Model 515. Model 520 Model 515. Model 510. Model 510 Surge Protective Devices Installation & Operation Manual Model 520 Model 515 Model 520 Model 515 Model 510 Model 510 ASCO SURGE PROTECTIE DEICE INSTALLATION, OPERATION AND MAINTENANCE MANUAL TABLE OF CONTENTS

More information

Solaris 8 6/00 Sun Hardware Roadmap

Solaris 8 6/00 Sun Hardware Roadmap Solaris 8 6/00 Sun Hardware Roadmap This document is a guide to the CDs and documents involved in installing the Solaris 8 6/00 software. Note The arrangement of CDs in the Solaris 8 product is different

More information

QUICK INSTALL GUIDE READ ME FIRST XWC Package Contents: XWC-1000 Wireless Controller. Rack Mount Kit. Power Cord. Wireless Controller

QUICK INSTALL GUIDE READ ME FIRST XWC Package Contents: XWC-1000 Wireless Controller. Rack Mount Kit. Power Cord. Wireless Controller READ ME FIRST QUICK INSTALL GUIDE Wireless Controller WC-1000 Package Contents: WC-1000 Wireless Controller Rack Mount Kit Power Cord BEFORE YOU BEGIN INSTALLATION Access Point Firmware: Be sure that the

More information

R SERIES INSTALLATION GUIDE

R SERIES INSTALLATION GUIDE R SERIES INSTALLATION GUIDE Welcome to your smartest install yet. Things you should know Latch R is a proximity reader, keypad, and wireless entry system, that can be operated as a standalone device or

More information

110 SERIES SINGLE-WAN GIGABIT VPN ROUTERS

110 SERIES SINGLE-WAN GIGABIT VPN ROUTERS 110 SERIES SINGLE-WAN GIGABIT VPN ROUTERS AN-110-RT-2L1W AN-110-RT-2L1W-WIFI Federal Communication Commission Interference Statement This equipment has been tested and found to comply with the limits for

More information

SunVTS Quick Reference Card

SunVTS Quick Reference Card SunVTS Quick Reference Card Sun Microsystems, Inc. 901 San Antonio Road Palo Alto, CA 94303-4900 U.S.A. 650-960-1300 Part No. 806-6519-10 January 2001, Revision A Send comments about this document to:

More information

MLC Plus 84 D Setup Guide

MLC Plus 84 D Setup Guide MLC Plus 84 D Setup uide IMPORTANT: o to www.extron.com for the complete user guide, installation instructions, and specifications before connecting the product to the power source. Figure 1. DISPLAY ON

More information

--- For a screen 1,196 x 1,196 x 50 mm Equivalent absorption area for an object A (m 2 )

--- For a screen 1,196 x 1,196 x 50 mm Equivalent absorption area for an object A (m 2 ) 1-2. Stereo screens Stereo screens may be suspended from the ceiling at various heights or mounted on a freestanding base and are designed to provide a high level of sound absorption for large open spaces.

More information

Meraki MR84. Hardware Installation Guide

Meraki MR84. Hardware Installation Guide Meraki MR84 Hardware Installation Guide Trademarks Cisco, Cisco Meraki, Meraki, Meraki MR84, and Meraki Cloud Controller are trademarks of Cisco Systems, Inc. Other brand and product names are registered

More information

LIDA Light Engine Instruction Manual

LIDA Light Engine Instruction Manual LIDA Light Engine Instruction Manual Lumencor, Inc. Document Number 57-10005, Rev. A www.lumencor.com Regulatory Models Lumencor utilizes regulatory model names for all certified and CE marked products.

More information

ControlNet PCI Communication Interface Card

ControlNet PCI Communication Interface Card Installation Instructions ControlNet PCI Communication Interface Card Catalog Number 1784-PCIC and 1784-PCICS The 1784-PCIC and -PCICS cards are peripheral component interconnect (PCI) open-bus interface

More information

Remote I/O Scanner. Installation Instructions. (Catalog Number 1747-SN)

Remote I/O Scanner. Installation Instructions. (Catalog Number 1747-SN) Installation Instructions Remote I/O Scanner (Catalog Number 1747-SN) Inside...page Hazardous Location Considerations... 2 Environnements dangereux... 2 Overview... 3 Hardware Features... 4 Required Tools

More information

A computerized system to store and retrieve data on biological and biotechnological veterinary products of the American continent

A computerized system to store and retrieve data on biological and biotechnological veterinary products of the American continent Rev. sa. lech. Off. int. Epiz., 1992, 11 (3), 925 929 A computerized system to store and retrieve data on biological and biotechnological veterinary products of the American continent L.V. MELENDEZ *,

More information

C-DIAS Analog Input Module CAI 086 For eight, ±10V voltage inputs

C-DIAS Analog Input Module CAI 086 For eight, ±10V voltage inputs C-DIAS ANALOG INPUT MODULE CAI 086 C-DIAS Analog Input Module CAI 086 For eight, ±10V voltage inputs This analog input module is used for the input of voltage values in the range of ±100mV / ±1.0V and10v.

More information