DSK-XXXXC DSK-XXXXP. Telephone Entry Door Intercom

Size: px
Start display at page:

Download "DSK-XXXXC DSK-XXXXP. Telephone Entry Door Intercom"

Transcription

1 * 0 # DSK-XXXXA DSK-XXXXC DSK-XXXXP Telephone Entry Door Intercom 15

2 Channel Vision s DSK-Series door stations can interface with a variety of telephone entry control products to provide communication with the front door. They are available in a variety of configurations including options for a hidden camera and compatibility with Panasonic s popular KSU phone systems. These door stations also feature an integrated access control keypad which can be used to open an entrance gate or an electric door lock. The DSK-Series door stations install in a standard 3-gang junction box, making it a simple and affordable addition to any home. Features: hrust-proof faceplate hdiscrete speaker and microphone hhidden camera option available hfits a 3-gang box havailable in many different finishes Dimensions: Depth Behind Plate Plate Depth Only * 0 # 5.0 2

3 Understanding the model number: Part numbering: DP door plates DSK-0212C A (DS3-0212C shown for example only) C P P-0920, P-0921, & TE110/C-0920 compatible P-0930 compatible Panasonic KXT-624 compatible 222 Polished Brass 232 Antique Brass 252 Oil Rubbed Bronze 302 Satin Nickel 0 No camera 6 Color camera (6404) Understanding the compatibility options There are three different types of systems that DSK door stations can be used with. The compatibility for these different types of systems is indicated by the suffix of the model number which follows the 4-digit numerical code. If the suffix is the letter A, such as DSK-0212A, then the door plate is compatible with Channel Vision s telephone entry products including models P-0920, P-0921, C-0920, and TE110. If the suffix is the letter C, such as DSK-0212C, then the door plate is compatible with Channel Vision s Whole-House CAT5 Intercom Hub, model P If the suffix is the letter P, such as DSK-0212P, then the door plate is compatible with Panasonic KXT-624 and older KSU s. This station is not compatible with digital systems such as the KX-TDA50, KX-TDA100, KXT-824, or KXT-848. Please double check to be sure that you have purchased the correct model number for your application. 3

4 # TM Channel Vision Compatible (DSK-xxxxA) The DSK-0xxxA and DSK-6xxxA both interface with the Channel Vision s telephone entry controllers, P-0920 and P-0921 to provide audio and video communication with the front door. Using a 2-conductor wire, connect the Telephone Entry Controller to the empty screw terminal block on the door station (see diagram). For the camera, use RG6 for analog video and 18/2 wire for power. From Telephone Service Provider 12VAC 500mA CO Input Chime Unlock Door Intercom Power Phones Ring * or No CO 3/5 rng CO Input Strike Time Strike 12VAC Active Intercom Active Model C HANNEL P-0920 PRO V ISION TELEPHONE ENTRY CONTROLLER Telephones * 0 # House Telephones Panasonic Compatible (DSK-xxxxP) Channel Vision's Panasonic models are a compatible replacement for the Panasonic KXT They are an attractive alternative to the standard plastic door station sold by Panasonic. This product interfaces with Panasonic s KSU phone systems to provide communication with the front door. From Telephone Service Provider Using a 2-conductor wire, connect the door phone output of your Panasonic KSU to the empty screw terminal block on the door station Connect to the terminals marked TO SYS Panasonic KSU System Phones * 0 #

5 TM Channel Vision CAT5 Intercom ( DSK-xxxxC) Compatible The diagram below shows how to connect the DSK-xxxxC to Channel Vision s CAT5 Whole-House Intercom system. When the button is pressed on the DSK-xxxxC the ST-3000 Intercom Stations will generate a door chime. Pressing Answer/End will open communication with the DSK-xxxxC. Model DSK-6xxxC includes an analog 960H color camera. DSK-xxxxC ST-C5IDS S G P 500ft. max P-0930 Press here to answer door ST * 0 # Hub Link In A B C D Room 1 Room 2 Room 3 Room 4 Room 5 Room 6 Model P-0930 C HANNEL PRO V ISION Whole-House Intercom Link Out Using CAT5 wire, connect the P-0930 to the 110 connector on the door station Page Trigger Page Out IR Emitters Power +15VDC Using the Access Keypad Status Light: (Red) * 0 # Power Light: (Green) IMPORTANT: if power light does not illuminate, immediately disconnect power supply and check for correct polarity. Keypad 5

6 DSK Series Keypad Programming The DSK Series Keypad is an extremely versatile keypad that can be configured in the field. It has one built-in relay. It is ideal to control on electric lock, either fail safe or fail secure. It can also trigger a contact closure to activate an automatic door opener or gate operator. There are two additional open collector outputs. With 2 installer-provided external relays, up to 3 devices can be controlled. Keypad Connector Diagram CONFIGURATION PINS - CONFIG YELLOW- Anti Tailgate/internal Alarm (Do NOT Apply Voltage) PINK - Remote Bypass (Do NOT apply voltage) TAN - Earth Ground GRAY - Normally Closed BLUE - Common VIOLET - Normally Open VOLTAGE SELECT DC ONLY (Do NOT apply voltage) 12-24V (default), 27VDC Max - Jumper on 1 pin only 5V- Jumper on both pins BROWN - 24-hr Access (Do NOT apply voltage) BLACK - Ground ORANGE - Program (Do NOT apply voltage) RED - Input Voltage WHITE - Output A GREEN - Output B typical setup on page 17 RED - + Voltage, 27VDC Max BLACK - Ground YELLOW - Anti Tailgate If not used this must be connected to BLACK. By adding a door monitor switch between YELLOW and BLACK the door will relock immediately after opening. If the third output is set up as an internal Alarm, this switch will trigger the alarm if the door is opened without a code or if the door is left open longer than the Door Ajar Time setting. PINK - Remote Bypass Connect a normally Open push button between PINK and BLACK to trigger the main output for its normal Door Open Time Setting ORANGE - Set Up Programming Momentarily connecting ORANGE to BLACK puts the unit in Set Up Mode (Same as entering *3, Master Code #) BROWN - 24-hour Access If Time Clock is enabled in Set up, and the BROWN wire is grounded, all codes work normally. When the BROWN wire is not grounded, only those codes with 24-hour Access Authorization will function. 6

7 Keypad Configuration Voltage Selection The factory default setting for th keypad voltage is 12-24VDC. Verify that the jumper is removed or placed over only one pin. For 5VDC, the jumper should be placed across both pins. If changing the voltage is necessary, make sure the power is removed first. Keypad Output Selection THE KEYPAD OUTPUT IS FACTORY CONFIGURED AND DOES NOT NEED TO BE RECONFIGURED IN THE FIELD Once the voltage jumper is verified or correctly set (see above) 1. Remove power 2. Jumper the tow pins above the connector labeled CONFIG 3. Apply appropriate power (You should hear 4 beeps and the RED LED will flash and the GREEN LED will be solid) 4. Now that the keypad is in configuration mode, select the desired output by entering the configuration number followed by #. a. Keypad Output Keypad Output Configuration Self-Contained- Non-encoded 99# b. (OPTIONAL) To change the audible beep, enter Code Audible Beep 201# Normal Beep (factory default) 200# Short Click (quieter) 5. Remove power. 6. Remove configuration jumper 7. Re-apply power. IMPORTANT: Once the configuration is selected, you must remove power, remove the configuration jumper and then re-apply power in order to complete the configuration procedure. Note: If the configuration jumper is not removed, the LED s will flash and the Keypad will beep continuously. Keypad Reset In certain cases you may want to erase all user codes and restore system defaults. To perform this procedure 1. Remove Power 2. Jumper the two pins above the connector labeled CONFIG 3. Apply appropriate power (You should hear 4 beeps and the RED LED will flash and the GREEN LED will be solid) 4. Once the keypad is in configuration mode, enter 0099#. The keypad will beep twice and both LEDs will flash for approximately 10 seconds (During this time the keypad will appear dead. Do NOT remove power!) 5. Wait and you will hear 4 beeps and the RED LED will flash and the GREEN LED will be solid. 6. Enter the configuration number followed by #. a. Keypad Output Keypad Output Configuration Self-Contained- Non-encoded 99# b. (OPTIONAL) To change the audible beep, enter Code Audible Beep 201# Normal Beep (factory default) 200# Short Click (quieter) 7. Remove power. 8. Remove configuration jumper 9. Re-apply power. 7

8 Configuration Input Requirements The DSK keypad accepts 5VDC or 12-24VDC. System current draw (max) is as follows: - Standby: 25mA - During Operation: 100mA Output Capabilities: Main Door Output SPDT relay rated at 24V 2A Max Output A A transistor output intended to drive a relay that can be programmed for one of the following: 1. CCTV or Light Controller - First key press triggers a Timed Output (1 to 99 seconds) 2. Auxiliary Output - Manual Control or Timed Output (1 to 99 seconds) 3. Second Door - Users can be assigned to open a 2nd door 4. Doorbell - Press # at the Keypad to trigger a 1 second output for a doorbell (not included) Output B A transistor output intended to drive a relay that can be programmed for one of the following: 1. CCTV or Light Controller - First key press triggers a Timed Output (1 to 99 seconds) 2. Auxiliary Output - Manual Control or Timed Output (1 to 99 seconds) 3. Third Door - Users can be assigned to open a 3rd door 4. Internal Alarm System - Detect Break-in, Door-ajar & Tamper 5. Doorbell - Press # at the Keypad to trigger a 1 second output for a doorbell (not included) Programming Overview There are two programming commands used with the DSK Keypad. *3 is the Programming System Setup. This programming command allows the programming of the Master Code, setting the main relay opening time, allows latching (toggling) of the main relay, etc. *1 is the Programming Command for programming user codes (page #). When programming the user codes, you have the ability to assign users authorizations. You can authorize a user to latch (if the system was set up to latch in the *3 programming sequence), you can allow a user to program or delete codes or activate one of the other outputs, etc. The DSK Keypad is configured at the factory. Under normal installation, there is no need to configure or reset the keypad unless the beeper needs to be quieter. The Default Master Code is: The Relay on Time is: 5 sec 8

9 Programming System Setup - Continued Changing the Master Code (Default 1-2-3) A. Enter: * 3 B. Enter the default Master Code followed by # 123# C. Enter: 1 # D. Enter the NEW Master Code followed by # 333# (new pass code you set) E. Enter: ** to exit programming Keypad Status After Step Completion Step Beep Red LED Green LED A Double Fast Flash Slow Flash B Triple Fast Flash Solid Note: If you forget the Master Code, momentarily ground the ORANGE wire. This will take you to Programming System Setup. Once you enter setup mode, you have 30 seconds to begin the program sequence. - Setting the Main Door Open Time (Default: 5 Seconds) A. Enter 2 # B. Enter the desired Door Open Time (1-99 Seconds), followed by # Example: 2 # 1 5 # (15 Sec. Door Open Time) C. Return to Step 3 or enter * * to exit programming. Keypad Status After Step Completion Step Beep Red LED Green LED A Double Fast Flash Slow Flash B Triple Fast Flash Solid - Setting Latching Option (Default: Off) A. Enter 3 # B. Select the desired latching option: Off- 0 # Manual- 9 9 # Timed- Enter the desired time interval in hours (1-98), followed by # Example: 3 # 8 # (Sets timed latching for 8 hours) C. Return to Step 3 or enter * * to exit programming. Step Beep Red LED Green LED A Double Fast Flash Slow Flash B Triple Fast Flash Solid - Configuring Output A (Default: Aux #1) A. Enter 4 # B. Select one of the following: - CCTV / External Light 1) Enter 1 # 2) Enter the desired On Time (1-99 seconds), followed by # Example: 4 # 1 # 1 5 # (Sets CCTV/Light Option for 15 Seconds) - Auxiliary Device Number 1 1) Enter 2 # 2) Enter the momentary output time (1-99 seconds), followed by #; -or- Enter 0 to set the auxiliary device for Manual Operation (ON/OFF), followed by # 9 Example: 4 # 2 # 0 # (Sets Auxiliary Device with Manual Operation)

10 Programming System Setup - Continued - Second Door 1) Enter 3 # 2) Enter the desired Door Open Time (1-99 seconds), followed by # 3) Select the desired latching method: Off- 0 # Manual- 9 9 # Timed- Enter the desired time interval in hours (1-98), followed by # Example: 4 # 3 # 5 # 9 9 # (Sets Second Door with 5 second Door Open Time and Manual Latching) - Doorbell 1) Enter 4 # C. Return to Step 3 or enter * * to exit programming. Keypad Status After Step Completion Step Beep Red LED Green LED A Double Fast Flash Slow Flash 1) Double Fast Flash Fast Flash 2) Triple Fast Flash Solid - Configuring Output B (Default: CCTV) A. Enter 5 # B. Select on of the following: - CCTV / External Light 1) Enter 1 # 2) Enter the desired On Time (1-99 Seconds), followed by # Example: 5 # 1 # 1 5 # (Sets CCTV/Light Option for 15 seconds) - Auxiliary Device Number 2 1) Enter 2 # 2) Enter the momentary output time (1-99 seconds) followed by #; -or- Enter 0 to set the auxiliary device for Manual Operation (ON/OFF), followed by # Example: 5 # 2 # 0 # (Sets Auxiliary Device with Manual Operation) - Third Door 1) Enter 3 # 2) Enter the desired Door Open Time (1-99 seconds), followed by # 3) Select the desired latching method: Off- 0 # Manual- 9 9 # Timed- Enter the desired time interval in hours (1-98), followed by # Example: 5 # 3 # 5 # 9 9 # (Sets Second Door with 5 second Door Open Time and Manual Latching) - Doorbell 1) Enter 4 # - Internal Alarm 1) Enter 5 # 2) Enter the desired Door Ajar Time (1-99 seconds, followed by # Example: 5 # 5 # 1 0 # (Sets Internal Alarm with 10 second Door Ajar Time) Output is normally ON and turns OFF when triggered. C. Return to Step 3 or enter * * to exit programming. 10

11 Programming System Setup - Continued - Master Code Door Unlock Option (Default: Allow) A. Enter 6 # B. Enter 0 # to prevent the master code from unlocking the door C. Enter 1 # to allow the master code to unlock the door D. Return to Step 3 or enter * * to exit programming. - Time Clock Input (Default: Prevent) A. Enter 7 # B. Enter 0 # to prevent lockout C. Enter 1 # to lockout all users that do not have 24 hour option enabled D. Return to Step 3 or enter * * to exit programming. Normal System Operation Keypad LED Status Indicators - A solid green LED indicates that the door is unlocked - A solid red LED indicates that the door is locked Depending on how the System Options are configured, User Commands are used to operate Manual Latching and Auxiliary Outputs. The User Commands are trailing digits entered after an authorized user code followed by #. The ability to use these User Commands depends on Authorizations assigned to each User (See Programming Individual Users) As the Main Output activates, the green LED will flash for 5 seconds. While the green LED is flashing, enter one (or more) of the following User Commands: 0 # to Latch the Door Closed (Main Relay, 2nd Door or 3rd Door) 1 # to Latch the Door Open (Main Relay, 2nd Door or 3rd Door) 2 # to Turn Output A Off (2nd Output as Aux.) 3 # to Turn Output A On (2nd Output as Aux.) 4 # to Turn Output B Off (3rd Output as Aux.) 5 # to Turn Output B On (3rd Output as Aux.) Tamper Alarm An audible Tamper Alarm sounds when four incorrect code entries are made. After 30 seconds, the unit returns to standby mode. 11

12 Programming Individual Users Authorized Users (master code or any user authorized to program) can program users directly from the Keypad. Each individual User can be assigned various authorizations. Review System Setup before programming individual users. 1) Enter * 1 2) Enter an Authorized Code followed by # Example: * # This opens programming and causes: Red LED Green LED Slow Flash Solid 3) Proceed to on of the following seven programming options - Adding a New User A. Enter 1 # B. Enter the User ID (1 to 500) followed by # C. Enter the User Code/PIN (3-8 digits), followed by # D. FOR NO AUTHORIZATIONS, SKIP TO STEP E. To give special authorizations, enter the Authorization Code, followed by #. Repeat for additional authorizations Code User Authorization 1 Latching Authorization 2 Program or Delete Users Authorization 3 Output A Authorization (see notes **) 4 2nd Door (see notes **) 5 Output B Authorization (see notes **) 6 3rd Door (see notes **) 7 24-hour Access (see notes **) E. Enter # to complete programming for this User. F. To program an additional User, return to Step B. G. If no more Users are to be added, enter * * and return to Step 3, or if you have completed all User Programming, enter * * a second time to complete programming sequence and reset system to normal operation. Keypad Status After Step Completion Step Beep Red LED Green LED A Double Slow Flash Slow Flash B Double Slow Flash Fast Flash C Double Slow Flash Fast Flash D Double Slow Flash Fast Flash E Triple Slow Flash Slow Flash ** Notes on Adding New Users: - Auxiliary Device or 2nd or 3rd Door authorization depends on configuration of the A and B Outputs. See System Setup on page 12 - If either Output is configured for 2nd or 3rd Door operation and a user is given 4# or 6# Authorization, their User Code will activate the configured output, not the Main Relay - 24-hour Access requires an external time clock or keyswitch. This allows you to restrict access to Users who are not assigned 24-hour Access. See Time Clock Input on page

13 Programming Individual Users - Continued - Modify a user by User ID A. Enter 2 # B. Enter the User ID (1 to 500) for the User to be modified, followed by # C. To change this User s Code, enter the New User Code followed by # - OR, see step D below - D. To keep this User s Code, enter #. Then, enter the desired User Authorization, followed by #. (Repeat for additional authorizations or skip to Step E for no authorizations) Code User Authorization 1 Latching Authorization 2 Program or Delete Users Authorization 3 Output A Authorization (see notes **) 4 2nd Door (see notes **) 5 Output B Authorization (see notes **) 6 3rd Door (see notes **) 7 24-hour Access (see notes **) E. Enter # to complete programming for this User F. To modify an additional User, return to Step B. G. If no more Users are to be modified, enter * * and return to Step 3, or if you have completed all User Programming, enter * * a second time to complete programming sequence and reset system to normal operation. - Modify a User by User Code A. Enter 3 # B. Enter the User Code for the User you wish to modify, followed by # C. To change this User s Code, enter the New User Code followed by # - OR, see step D below - D. To keep this User s Code, enter #. Then, enter the desired User Authorization, followed by #. (Repeat for additional authorizations or skip to Step E for no authorizations) Code User Authorization 1 Latching Authorization 2 Program or Delete Users Authorization 3 Output A Authorization (see notes **) 4 2nd Door (see notes **) 5 Output B Authorization (see notes **) 6 3rd Door (see notes **) 7 24-hour Access (see notes **) E. Enter # to complete programming for this User F. To modify an additional User, return to Step B. G. If no more Users are to be modified, enter * * and return to Step 3, or if you have completed all User Programming, enter * * a second time to complete programming sequence and reset system to normal operation. ** Note on Modifying Users: - Once you have begun to modify a User, previously programmed authorizations are deleted for this User. 13

14 Programming Individual Users - Continued - Deleting a User by User ID A. Enter 4 # B. Enter the User ID (1 to 500) for the User to be deleted, followed by # C. To delete an additional User, return to Step B. D. If no more Users are to be deleted, enter * * and return to Step 3, or if you have completed all User Programming, enter * * a second time to complete programming sequence and reset system to normal operation. - Deleting a User by User Code A. Enter 5 # B. Enter the User code to be deleted, followed by # C. To delete an additional User, return to Step B. D. If no more Users are to be deleted, enter * * and return to Step 3, or if you have completed all User Programming, enter * * a second time to complete programming sequence and reset system to normal operation. - Adding a Temporary User A. Enter 6 # B. Enter the User Code / PIN (3-8 digits), followed by # C. Enter the desired Temporary Access Time (1-99 hours), followed by # D. For 24-hour Access, enter 0 for No or 1 for Yes, followed by # E. You are now back to Step 3 (page 13) - Deleting a Temporary User A. Enter 7 # B. Your are now back to Step 3 (page 13) 4. Enter * * to complete the sequence and reset the system to normal operation. Input Requirements: Voltage: 5V DC or 12 to 24V DC (Jumper Selectable) System current draw (maximum): 100 ma Standby: 25mA During Operation:.10 amps max (100 ma) Outputs: 1 Relay, 2A 24V Max; 2 Open Collector, 1/4 A max to Ground Keypad Switch Life: >1 Billion Cycles Programmable Output: 1 to 99 seconds (Door Open Time) (Default - 5 Seconds) Latching: Off (Default), Manual (Toggle On/Off) Timed # of Users: 502 (1 Master User, 500 Users, 1 Temporary User Code Length: 3 to 8 Digits Default Master Code: Tamper Alarm: 4 Incorrect Code Attempts Access Code Protection: Non-Volatile Memory Keypad Operating Environment: -40 C to +70 C (-40 to +160 F) 100% Relative Humidity 14 Keypad Specifications

15 Ground (Black) N.O. (Violet) Common (Blue) TM Negative - Integrating the ST-C5IDS For systems using the P-0930 P-0930 Press and hold door station number to activate ST-C5IDS NEW ST-3000 Hub Link In A B C D Room 1 Room 2 Room 3 Room 4 Room 5 Room 6 Model P-0930 C HANNEL PRO V ISION Whole-House Intercom Link Out Page Trigger IR Power Page Out Emitters +15VDC ST-C5ID (Sold Separately) (Rear View) * 0 # S G P Keypad Power 12V/24VDC + (Red) Negative - Strike Power Supply DC + Positive Door strike Mechanism (NOT SOLD BY CHANNEL VISION) Connect the VIOLET and BLUE wires from the back of the DSK Keypad into the strike terminals on the ST-C5IDS. The negative wire (cut in two) of the power supply of the strike should also be applied to the strike terminal on the ST-C5IDS. To open the door, press and hold the room button on the ST-3000, or enter the code on the DSK Keypad. 15

16 Ground (Black) N.O. (Violet) Common (Blue) # TM Integrating the TE110DS For systems using P-0920 or P-0921 The example shown is a P-0920 and normally open lock type. TE110DS (Sold Separately) Fail-Secure Lock (N.O.) Strike Power Supply * 0 # House Intercom Strike Connect the VIOLET and BLUE wires from the keypad to the Unlock Door terminals on the P-0920 or P Triggering the keypad will cause the P-0920 to activate the TE110DS or the P-0921 to activate the Aux terminal or TE110DS and allow the door to open. + Keypad Power 12V/24VDC + (Red) 12VAC 500mA CO Input Chime Unlock Door Intercom Power Phones Ring Connect direct power or share power with button on the TE-AMP(optional) * or No CO 3/5 rng Strike Time Strike 12VAC Active Intercom Active Model C HANNEL P-0920 PRO V ISION Telephone Company TELEPHONE ENTRY CONTROLLER CO Input Telephones P-0920 House Telephones 16

17 Typical Lock Hook-Up 12-24VDC Power Supply Lock Negative side MOV RED Blue BLACK YELLOW Black=Button K E Y P A D MOV Pink = Button Lock Positive side FAIL SAFE FAIL SECURE VIOLET= N.Open Lock GRAY = NC lock TAN = Earth Ground Typical Garage Door or Gate Hook-up 12-24VDC Power Supply Across Push Button or strike from TE110DS door strike relay RED BLACK YELLOW Black Violet K E Y P A D TAN Earth Ground 17

18 Troubleshooting These are a few troubleshooting suggestions to help assist with any problems you may experience. You may contact Channel Vision Technical Support at (714) option two, or techsupport@channelvision.com Changed or Deleted a code and the old code still works: The DSK Series Keypad has a total of 500 User Codes. Make sure you ve changed the desired code. If you changed the Master Code, the other User Codes will still work. If in doubt, it is recommended you reprogram the master code and delete all user codes. Then re-program any new user codes. Keypad beeps but the door does not unlock: You will want to check all of your wiring terminations, splices, and any other connection to ensure they are all properly seated, connected and making good contact. Programming - If the unit has just been installed, the problem is most likely with programming the system codes. Review Overview and Programming of User Codes again remembering that all six codes have to be different from each. It is also important not to let more than 5 seconds elapse between button presses or the system will reset and you will have to start over. Code Loss - (Existing installations) There are typically two reasons for code loss: static or inductive kickback. There is no way to determine if the system has been affected by either of these, however, you can reprogram the system codes as described in User Code Programming. It is very important the system is properly grounded otherwise static and code loss may be an ongoing problem. Keypad does not power up: First, check your power supply to see that power has not been cut off. Using a voltmeter, check the incoming voltage on the RED and BLACK wires (12-24V AC/DC IN). If the voltage reads low, the electric locking device may be drawing too much current. To test, remove the wires to the device and recheck the voltage. If the voltage now reads normal, check the current draw of the locking device and make sure it falls within the system specifications (see Input Requirements). Random Beeping: Possible low voltage or bad power supply. Also, check EARTH ground. 18

19 One Year Limited Warranty Channel Vision Technology will repair or replace any defect in material or workmanship which occurs during normal use of this product with new or rebuilt parts, free of charge in the USA, for one year from the date of original purchase. This is a no hassle warranty with no mail in warranty card needed. This warranty does not cover damages in shipment, failures caused by other products not supplied by Channel Vision Technology, or failures due to accident, misuse, abuse, acts of God, or alteration of the equipment. This warranty is extended only to the original purchaser when purchased through an authorized reseller. A purchase receipt, invoice, or other proof of original purchase date will be required before warranty repairs are provided. Mail in service can be obtained during the warranty period by calling (800) toll free. A Return Authorization number must be obtained in advance and can be marked on the outside of the shipping carton. This warranty gives you specific legal rights and you may have other rights (which vary from state to state). If a problem with this product develops during or after the warranty period, please contact Channel Vision Technology, your dealer or any factory-authorized service center. Channel Vision products are not intended for use in medical, lifesaving, life sustaining or critical environment applications. Channel Vision customers using or selling Channel Vision products for use in such applications do so at their own risk and agree to fully indemnify Channel Vision for any damages resulting from such improper use or sale. (Typical at 77º) Operating Voltage - Keypad: Operating Voltage - Communication: Cable Requirements - Camera: Cable Requirements- Communication: Speaker impedance: Operating Temperature: 12vDC 100mA 12vDC 60mA RG6 Coaxial Cable for Camera Video (or 2 conductor CAT5/6 with B-201 balun x2 1 18/2 or 2 conductor CAT5/6 for power. 1 18/2 power wire for amplified companion board, button & keypad 2 Conductor CAT5/6 for companion board (communication) 2 Conductor CAT5/6 for keypad (contact closure for strike) 8 ohm -10ºC to +50ºC Tested To Comply With FCC Standards This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation. Intelligent Entertainment Infrastructure Security Solutions 234 Fischer Avenue, Costa Mesa, California USA (714) techsupport@channelvision.com w w w. c h a n n e l v i s i o n. c o m rev D 19

SKE Series. 12-Pad. Installation & Instruction Manual. Essex Electronics, Inc KEY-LESS fax keyless.

SKE Series. 12-Pad. Installation & Instruction Manual. Essex Electronics, Inc KEY-LESS fax keyless. SKE Series 12-Pad Installation & Instruction Manual Essex Electronics, Inc. 805.684.7601 800.KEY-LESS fax 805.684.0232 keyless.com SKE Series 12-Pad Self-Contained Keyless Entry System With Relay All rights

More information

K-PROX Series INSTALLATION & INSTRUCTION MANUAL. Essex Electronics, Inc KEY-LESS fax keyless.com

K-PROX Series INSTALLATION & INSTRUCTION MANUAL. Essex Electronics, Inc KEY-LESS fax keyless.com K-PROX Series INSTALLATION & INSTRUCTION MANUAL K-Prox Series Self-Contained Keyless Entry System All rights reserved. No part of this documentation may be reproduced in any form, without prior written

More information

INSTALLATION INSTRUCTIONS Model 930 EntryCheck

INSTALLATION INSTRUCTIONS Model 930 EntryCheck SECURITY DOOR CONTROLS 3580 Willow Lane, Westlake Village, CA 91361-4921 (805) 494-0622 Fax: (805) 494-8861 www.sdcsecurity.com E-mail: service@sdcsecurity.com INSTALLATION INSTRUCTIONS Model 930 EntryCheck

More information

AB-315. ibus Wall-Dock for A-Bus Audio Systems

AB-315. ibus Wall-Dock for A-Bus Audio Systems AB-315 ibus Wall-Dock for A-Bus Audio Systems TM By 10 The AB-315 is an on-wall ipod docking station for A-BUS audio systems. The dock connector slides in and out to adjust for any ipod and the non-skid

More information

SECURITY DOOR CONTROLS 801 Avenida Acaso, Camarillo, Ca (805) Fax: (805)

SECURITY DOOR CONTROLS 801 Avenida Acaso, Camarillo, Ca (805) Fax: (805) SECURITY DOOR CONTROLS 801 Avenida Acaso, Camarillo, Ca. 93012 (805) 494-0622 Fax: (805) 494-8861 www.sdcsecurity.com E-mail: service@sdcsecurity.com INSTALLATION INSTRUCTIONS Model 931 EntryCheck The

More information

A0319. Bluetooth Wall-Dock for Distributed Audio. Intelligent Entertainment Infrastructure Security Solutions

A0319. Bluetooth Wall-Dock for Distributed Audio. Intelligent Entertainment Infrastructure Security Solutions A0319 Bluetooth Wall-Dock for Distributed Audio Intelligent Entertainment Infrastructure Security Solutions The A0319 is an on-wall bluetooth docking station that will charge an ipod, iphone or itouch

More information

BRN WHT/BRM BLU WHT/BLU GRN WHT/GRN ORG WHT/ORG

BRN WHT/BRM BLU WHT/BLU GRN WHT/GRN ORG WHT/ORG IN OUT 1 2 3 4 WHT/ WHT/ by Audio In IR Emitters AB-404 AB-301 AB-124 A-BUS Audio System By 12 by The Channel Vision A-BUS Audio system can distribute high-quality audio to every room in your house over

More information

K1-ERM INSTALLATION & INSTRUCTION MANUAL. Essex Electronics, Inc KEY-LESS fax keyless.com

K1-ERM INSTALLATION & INSTRUCTION MANUAL. Essex Electronics, Inc KEY-LESS fax keyless.com K1-ERM INSTALLATION & INSTRUCTION MANUAL K1-ERM Encoded Keyless Entry Access Control System All rights reserved. No part of this documentation may be reproduced in any form, without prior written consent

More information

PRO PRO ST-2000 ST-2100 P CAT5 Whole-House Intercom System

PRO PRO ST-2000 ST-2100 P CAT5 Whole-House Intercom System 1 hannel Vision Technology will repair or replace any defect in material or workmanship which occurs during normal use of this product with new or rebuilt parts, free of charge in the US, for one year

More information

INSTALLATION INSTRUCTIONS 920 EntryCheck TM

INSTALLATION INSTRUCTIONS 920 EntryCheck TM 801 Avenida Acaso, Camarillo, Ca. 93012 (805) 494-0622 www.sdcsecurity.com E-mail: service@sdcsecurity.com INSTALLATION INSTRUCTIONS 920 EntryCheck TM The EntryCheck 920 Indoor/Outdoor Keypad is a surface-mount

More information

A0316D. IBus Wall-Dock for Distributed Audio

A0316D. IBus Wall-Dock for Distributed Audio A06D IBus Wall-Dock for Distributed Audio M By he A06 is an on-wall ipod docking station for distributed audio and supports IR functions. he dock connector slides in and out to adjust for any ipod and

More information

INSTALLATION INSTRUCTIONS 920P EntryCheck TM

INSTALLATION INSTRUCTIONS 920P EntryCheck TM 801 Avenida Acaso, Camarillo, Ca. 93012 (805) 494-0622 www.sdcsecurity.com E-mail: service@sdcsecurity.com INSTALLATION INSTRUCTIONS 920P EntryCheck TM The EntryCheck 920P Indoor/Outdoor Keypad is a surface-mount

More information

INSTALLATION INSTRUCTIONS 921P EntryCheck TM

INSTALLATION INSTRUCTIONS 921P EntryCheck TM 80 Avenida Acaso, Camarillo, Ca. 90 (805) 494-06 www.sdcsecurity.com E-mail: service@sdcsecurity.com INSTALLATION INSTRUCTIONS 9P EntryCheck TM The EntryCheck 9P Indoor/Outdoor Keypad is a surface mount

More information

MODEL KP-100 ACCESS CONTROL DIGITAL KEYPAD OPERATING INSTRUCTIONS

MODEL KP-100 ACCESS CONTROL DIGITAL KEYPAD OPERATING INSTRUCTIONS MODEL KP-100 ACCESS CONTROL DIGITAL KEYPAD OPERATING INSTRUCTIONS Model KP-100 is a self-contained digital keypad. This keypad is suitable for residential, industrial, and commercial installations. It

More information

A Watt Stereo Amplifier

A Watt Stereo Amplifier A0240 40 Watt Stereo Amplifier 8 The A0240 is a 2-channel 40 Watt class D amplifier. It can be used to power a small 1-room audio system or integrated with Channel Vision s A0302 to provide supplemental

More information

AB-910W. A-Bus Two Zone Audio Kit w/bluetooth & 2 pair In-Wall Speakers. Intelligent Entertainment Infrastructure Security Solutions CHANNEL VISION

AB-910W. A-Bus Two Zone Audio Kit w/bluetooth & 2 pair In-Wall Speakers. Intelligent Entertainment Infrastructure Security Solutions CHANNEL VISION IR Out Local In Sys Priority Loc 24VDC Channel Vision AB-910W A-Bus Two Zone Audio Kit w/bluetooth & 2 pair In-Wall Speakers R Intelligent Entertainment Infrastructure Security Solutions Product Introduction

More information

212iL Rev. 1.1

212iL Rev. 1.1 212iL 1 International Electronics, Inc. 427 Turnpike Street Canton, Massachusetts 02021 212iL (illuminated Luxury) Keypad Single Unit Keypad- Control Installation Manual Features: 120 User Capability Illuminated

More information

AK-21. Digital Keyless Entry System. Installation and Programming Instructions

AK-21. Digital Keyless Entry System. Installation and Programming Instructions AK-2 Digital Keyless Entry System Installation and Programming Instructions (760) 8-7000 USA & Canada (800) 2-587 & (800) 92-02 Toll Free FAX (800) 68-0 www.linearcorp.com CONTENTS COMPONENT LOCATIONS.......................................

More information

INSTALLATION INSTRUCTIONS Model 935 EntryCheck

INSTALLATION INSTRUCTIONS Model 935 EntryCheck SECURITY DOOR CONTROLS 3580 Willow Lane, Westlake Village, CA 91361-4921 (805) 494-0622 Fax: (805) 494-8861 www.sdcsecurity.com E-mail: service@sdcsecurity.com INSTALLATION INSTRUCTIONS Model 935 EntryCheck

More information

A0315. ibus Wall-Dock for CAT5 Audio Systems

A0315. ibus Wall-Dock for CAT5 Audio Systems A015 ibus Wall-Dock for CAT5 Audio Systems By 10 The A015 is an on-wall ipod docking station for CAT5 audio systems. The dock connector slides in and out to adjust for any ipod and the nonskid pad helps

More information

KE-265. Keyless Entry Access Control System. Installation and Operations Manual

KE-265. Keyless Entry Access Control System. Installation and Operations Manual KE-265 Keyless Entry Access Control System Installation and Operations Manual ESSEX ELECTRONICS, INC. KE-265 Series All rights reserved. No part of this documentation may be reproduced in any form, without

More information

CHANNEL VISION. Pwr Source A0125. Multi-Source Volume Control Keypad

CHANNEL VISION. Pwr Source A0125. Multi-Source Volume Control Keypad CHANNEL VISION A0125 Multi- Volume Control Keypad 8 The A0125 is a volume control keypad for s single-source and multi-source CAT5 audio systems. It provides convenient volume control and source selection

More information

2000 Series e/em Style Keypad Installation and Programming Manual

2000 Series e/em Style Keypad Installation and Programming Manual 2000 Series e/em Style Keypad Installation and Programming Manual Document Number: 6054022 Revision: 0 Date: 12/21/06 Table of Contents Table of Contents Section 1: Introduction... 6 1 Product Description...6

More information

Digital Keypad Introduction

Digital Keypad  Introduction K2 Digital Keypad Introduction The K02 uses the latest microprocessor technology to operate door strikes and security systems that require a momentary (timed) or latching dry contact closure. All programming

More information

Keyless Entry KE-265. Access Control System INSTALLATION & INSTRUCTION MANUAL

Keyless Entry KE-265. Access Control System INSTALLATION & INSTRUCTION MANUAL KE-265 Keyless Entry Access Control System INSTALLATION & INSTRUCTION MANUAL Essex Electronics, Inc. 805.684.7601 800.KEY-LESS fax 805.684.0232 keyless.com KE-265 Keyless Entry Access Control System All

More information

SK-1011-SDQ Access Control Keypad. Manual

SK-1011-SDQ Access Control Keypad. Manual SK-1011-SDQ Access Control Keypad Manual Quick Installation Guide: This page is for installers looking to do a basic installation and programming of the keypad. For more in-depth installation and programming

More information

AS Keypad User Manual

AS Keypad User Manual AS Keypad User Manual Specifications Operating Voltage: 12~24 VAC/DC Current Draw: TBA Input: request-to-exit (for Relay 1) time out reed switch contact (for Relay 1) Output: Relay 1: N.O./N.C./Com. Output

More information

Intelligent Entertainment Infrastructure Security Solutions

Intelligent Entertainment Infrastructure Security Solutions Aria TM By CHANNEL VISION Flush Mount Amplifier Spkrs Active Local In IR In 24VDC A0915 ibus Wall-Dock Single Room Kit Intelligent Entertainment Infrastructure Security Solutions Product Introduction Simplify

More information

SK-1011-SQ Digital Access Keypad with 5A Relay Output

SK-1011-SQ Digital Access Keypad with 5A Relay Output User Operation for the SK--SQ. Using the User Codes: A. User codes operate the door (4-8 digits long). Press u u u u B. The key must also be pressed if the keypad is in manual-entry mode. Press u u u u

More information

Secured Series: Hub Plus Kit Single Door Controller Package Installation Manual

Secured Series: Hub Plus Kit Single Door Controller Package Installation Manual Secured Series: Hub Plus Kit Single Door Controller Package Installation Manual This package is designed to simplify the connections to our Secured Series Hub Plus Controller. This will translate into

More information

INSTALLATION INSTRUCTIONS 923P EntryCheck TM

INSTALLATION INSTRUCTIONS 923P EntryCheck TM 801 Avenida Acaso, amarillo, a. 93012 (805) 494-0622 www.sdcsecurity.com E-mail: service@sdcsecurity.com INSTALLATION INSTRUTIONS 923P Entryheck TM The Entryheck 923P Indoor/Outdoor Keypad is a surface

More information

system AB-114 / AB-202 AB-404 / AB-301 AB-T2454 Multi-room audio distribution system CHANNEL VISION Limited Warranty

system AB-114 / AB-202 AB-404 / AB-301 AB-T2454 Multi-room audio distribution system CHANNEL VISION Limited Warranty Trouble? ) Be sure you have connected the AT-5 cable correctly. Note that the stripe/solid pattern should match the labels on the product. Miss-wiring can cause distorted sound or prevent the system from

More information

INSTALLATION MANUAL. SIM/SIK/SI-8000 IP Intercom System ELITE

INSTALLATION MANUAL. SIM/SIK/SI-8000 IP Intercom System ELITE INSTALLATION MANUAL SIM/SIK/SI-8000 IP Intercom System ELITE SIM/SIK/SI- 8000Series IP Intercom System QUICK START GUIDE CONTENTS Introduction Specifications and Package Contents 1 Dimensions 2 Installation

More information

CHANNEL VISION POWER MODEL A0505 S O U R C E ZONE POWER CAMERA CATV MUTE MOD VOL A0505 REMOTE CONTROL

CHANNEL VISION POWER MODEL A0505 S O U R C E ZONE POWER CAMERA CATV MUTE MOD VOL A0505 REMOTE CONTROL HANNL VIIN L MT NTL The allows you to operate many of hannel Vision s whole-house audio/video systems without needing to touch the keypad. Additionally, this remote provides shuttle controls for the A05,

More information

KP2000E/EM Series Style Keypad

KP2000E/EM Series Style Keypad 23852973 KP2000E/EM Series Style Keypad Installation and Programming Instructions Models KP2000EXX and KP2000EMXX Specifications Parameter Voltage Requirements Keypad Current Requirements (Max) Relay Contact

More information

CM-110SK Standalone Keypad Installation Instructions

CM-110SK Standalone Keypad Installation Instructions CM-0SK Standalone Keypad Installation Instructions. Packing List Qty Name Remarks 2 2 Keypad User manual Screwdriver Wall plugs Self-tapping screws Torx screw 0.8 x 2.4 Φ(20 mm 60 mm) 0.24 x.2 Φ (6 mm

More information

232iLM Keypad Installation and Programming Instructions

232iLM Keypad Installation and Programming Instructions 232iLM Keypad Installation and Programming Instructions Note: This product is designed to be installed and serviced by security and lock industry professionals. Specifications Case Dimensions: 6 1 / 2

More information

RFID/Digital Access Control Keypad

RFID/Digital Access Control Keypad R Luminous/ RFID/Digital Access Control Keypad Model:YK-368L-R Germany EMC tested FEATURES AND FUNCTIONS Simple Programming, Easy Operation 3-Operation Mode: ID Card Operation, User Code Operation, ID

More information

Telephone Entry System

Telephone Entry System Telephone Entry System TE-200-II C-0902 (PCB w/ mounting plate) 234 FISCHER AVENUE COSTA MESA, CA 92626 (714) 424-6500 (800) 840-0288 (714) 424-6510 FAX HTTP://WWW.CHANNELVISION.COM E-MAIL: SALES@CHANNELVISION.COM

More information

DG-800 Stand-Alone Proximity Reader Instruction Manual

DG-800 Stand-Alone Proximity Reader Instruction Manual DG-800 Stand-Alone Proximity Reader Instruction Manual I. Features 1. Memory volume up to 1000+10 proximity cards/tokens and PINs with the programming time up to 0.5 seconds. 2. Access modes: a. Only Proximity

More information

INSTALLATION MANUAL SI/SIM/SIK/ DP IP Intercom System ELITE

INSTALLATION MANUAL SI/SIM/SIK/ DP IP Intercom System ELITE INSTALLATION MANUAL SI/SIM/SIK/ DP-8000 IP Intercom System ELITE SIM/SIK/SI- 8000Series IP Intercom System QUICK START GUIDE CONTENTS Introduction Specifications and Package Contents 1 Dimensions 2 Installation

More information

FEATURES AND PROGRAMMING GUIDE SELF-CONTAINED ACCESS CONTROL SYSTEMS:

FEATURES AND PROGRAMMING GUIDE SELF-CONTAINED ACCESS CONTROL SYSTEMS: FEATURES AND PROGRAMMING GUIDE SELF-CONTAINED ACCESS CONTROL SYSTEMS: 233CARDREADER DOOR-GARD SELF-CONTAINED ACCESS CONTROL SYSTEMS offer field proven reliability and cost effective solutions for residential,

More information

User Manual. PCKeypad Wireless Keypad

User Manual. PCKeypad Wireless Keypad User Manual PCKeypad Wireless Keypad Description The PCKeypad is a wireless keypad with a PentaCODE transmitter built-in. It works with all of Elsema s PCR series receivers. The installer has the option

More information

TEC100 USER/INSTALLER MANUAL V2.0 REV. 03/2018

TEC100 USER/INSTALLER MANUAL V2.0 REV. 03/2018 TEC100 USER/INSTALLER MANUAL V2.0 REV. 03/2018 00. CONTT 01. SAFETY INSTRUCTIONS INDEX 01. SAFETY INSTRUCTIONS STANDARDS TO FOLLOW 02. PRODUCT PRODUCT PROFILE TECHNICAL PARAMETERS 03. INSTALLATION PRODUCT

More information

ENFORCER SK-1131-SQ. Digital Access Keypad with 5A Relay Output MANUAL. Digital Access Keypad Manual. Also available from SECO-LARM: Outdoor Keypads

ENFORCER SK-1131-SQ. Digital Access Keypad with 5A Relay Output MANUAL. Digital Access Keypad Manual. Also available from SECO-LARM: Outdoor Keypads User Operation for the SK--SQ Note: n n n nindicates. Using the User Codes: A. User codes operate the door (4-8 digits long). the inhibit code. Note: u u u uindicates Press u u u u the user code. B. The

More information

9212i INSTALLATION. Stand-Alone Keypad. Instructions

9212i INSTALLATION. Stand-Alone Keypad. Instructions INSTALLATION 9212i Stand-Alone Keypad Instructions Features: 4 Independent Outputs 4 Independent Timers All Outputs Assignable by Code On board 5 Amp Form C Relay 120 Users Remote Triggering Input Keypad

More information

Installing Keypad and Backplate

Installing Keypad and Backplate Installing Keypad and Backplate Fig.1 Positioning of Fixing Holes and Cable Outlet Cable Outlet, Drill Diameter 10mm for Cable Access Remove the back plate, which is fitted to rear of the keypad, using

More information

Wireless Doorphone Intercom

Wireless Doorphone Intercom Security Made Smarter Wireless Doorphone Intercom EN INSTRUCTION MANUAL DOORBELL OVERVIEW MICROPHONE LEDS CAMERA LENS LIGHT SENSOR Detects ambient light and turns on the LEDS to provide clear color night

More information

e-ask electronic Access Security Keyless-entry OEM / Dealer / Installer Cargo Lock / Unlock Version Installation & Instructions (UM04 ~ )

e-ask electronic Access Security Keyless-entry OEM / Dealer / Installer Cargo Lock / Unlock Version Installation & Instructions (UM04 ~ ) e-ask electronic Access Security Keyless-entry OEM / Dealer / Installer Cargo Lock / Unlock Version Installation & Instructions (UM04 ~ 18990-04) Table of Contents Introduction... 1 e-fob Operation and

More information

VANDAL RESISTANT BACK-LIT WEATHERPROOF ACCESS CONTROL KEYPAD

VANDAL RESISTANT BACK-LIT WEATHERPROOF ACCESS CONTROL KEYPAD VANDAL RESISTANT BACK-LIT WEATHERPROOF ACCESS CONTROL KEYPAD Post Mount Keypad Programming & Installation Manual 1. Connect Power 12V DC to 24V AC/DC to terminals (+) and (-) Post Mount Keypad Quick Start

More information

CV-550SPK V2 Waterproof Keypad/Reader/Controller Installation Instructions

CV-550SPK V2 Waterproof Keypad/Reader/Controller Installation Instructions CV-550SPK V2 Waterproof Keypad/Reader/Controller Installation Instructions Packing List NAME MODEL/SIZE QTY Self tapping screw 0.15 x 1.06 (4mm 27 mm) Rubber plug 0.23 x 1.2 (6mm 30 mm) Star screw driver

More information

CV-110SPK Standalone Keypad/Prox Access Control Installation Instructions

CV-110SPK Standalone Keypad/Prox Access Control Installation Instructions CV-110SPK Standalone Keypad/Prox Access Control Installation Instructions 1. Packing List Qty Name Remarks 1 1 1 2 2 1 Keypad User manual Screwdriver Wall plugs Self-tapping screws Torx screw 0.8 x 2.4

More information

3228 Station Port FXS Doorphone

3228 Station Port FXS Doorphone 3228 Station Port FXS Doorphone Installation and User Guide Algo Communication Products Ltd., Burnaby, BC Canada V5J 5L2 280817-1 www.algosolutions.com - 1 - Document #: 90-00059C Important Safety Notice

More information

Installation Instructions

Installation Instructions Alliance Arming Station AL-1111, AL-1116 1048520C September 2006 Copyright 2006, GE Security Inc. Introduction This is the GE Alliance Arming Station for models AL-1111 (four-line LCD) and AL-1116 (four-line

More information

INSTRUCTION MANUAL DIGI-LOCK. Keyless Entry System. Installation. Programming. Troubleshooting. BASE Industries

INSTRUCTION MANUAL DIGI-LOCK. Keyless Entry System. Installation. Programming. Troubleshooting. BASE Industries INSTRUCTION MANUAL DIGI-LOCK Keyless Entry System Installation Programming Troubleshooting BASE Industries 45 Pomona Rd. Corona, CA. 9880 Revision F TABLE OF CONTENTS OWNER REGISTRATION CARD INTRODUCTION

More information

e-ask electronic Access Security Keyless-entry RF Keyless-entry entry System TM-Multi Multi Installation Manual FCC ID: TV2EFOB1 (UM21 ~ )

e-ask electronic Access Security Keyless-entry RF Keyless-entry entry System TM-Multi Multi Installation Manual FCC ID: TV2EFOB1 (UM21 ~ ) e-ask electronic Access Security Keyless-entry e-fob RF Keyless-entry entry System TM-Multi Multi Installation Manual FCC ID: TV2EFOB1 (UM21 ~ 22795-01) Table of Contents Introduction... 1 e-fob Operation

More information

Telephone Line Monitor USER GUIDE

Telephone Line Monitor USER GUIDE Telephone Line Monitor USER GUIDE For Technical Assistance call the Manufacturers direct Ph 800 530 8645 8AM - 5PM West Coast Pacific Time NATCOMM USA LLC Responsible Supplier Code NC OPERATION Our Telephone

More information

CM-500 SK 500 USER CODES KEYPAD

CM-500 SK 500 USER CODES KEYPAD CM-500 SK 500 USER CODES KEYPAD Wiring diagram PCB front view ST2 1 3 1 3 N/C contact RL1 (magnet) N/O contact RL1 (strike) ST1 3 2 1 ST2 1 3 RL2 RL1 Strike 2 1 E M B 3 5 T C O 12 V V1 PB2 PB1 Input voltage

More information

EntraGuard Bronze. Quick Start Guide. Telephone Entry. 1.0 Specifications. 2.0 Unit Installation

EntraGuard Bronze. Quick Start Guide. Telephone Entry. 1.0 Specifications. 2.0 Unit Installation The EntraGuard Bronze is a residential telephone keypad entry system which allows a homeowner to communicate directly with visitors and provide access by using any phone extension in the home. Because

More information

Section 1 General Description. Section 3 How to Program Keypad. Section 2 Installation. CM-120TX Wireless Digital Keypads Installation Instructions

Section 1 General Description. Section 3 How to Program Keypad. Section 2 Installation. CM-120TX Wireless Digital Keypads Installation Instructions CM-120TX Wireless Digital Keypads Installation Instructions Package Contents - (1) Keypad and faceplate assembly - (1) Foam gasket (CM-120W only) - (2) #6-32 x 1 S/S Phillips screws - (2) #6-32 x 1 Tamperproof

More information

180 Series Keypad. Handbook. Revision 2.1

180 Series Keypad. Handbook. Revision 2.1 180 Series Keypad Handbook Revision 2.1 Revision History Revision 1.0 Initial release Revision 2.0 Major update with addition of 180-40 Added 180-40 to document and various headings Note regarding unique

More information

DP2. Door Phone. For Technical Assistance call the Manufacturers direct ph AM - 5PM West Coast Pacific Time

DP2. Door Phone. For Technical Assistance call the Manufacturers direct ph AM - 5PM West Coast Pacific Time DP2 Door Phone For Technical Assistance call the Manufacturers direct ph 0800 530 8645 9AM - 5PM West Coast Pacific Time NATCOMM USA LLC Supplier Code : NC TABLE OF CONTENTS Description Page 3 Door Phone

More information

Owner s Manual. Models 1503 and 1504 Basic Stand Alone Digital Keypad Entry Devices

Owner s Manual. Models 1503 and 1504 Basic Stand Alone Digital Keypad Entry Devices Owner s Manual Models 1503 and 1504 Basic Stand Alone Digital Keypad Entry Devices DoorKing, Inc. 120 Glasgow Avenue Inglewood, California 90301 U.S.A. Phone: 310-645-0023 Fax: 310-641-1586 www.doorking.com

More information

Indoor/Outdoor Proximity Reader and Keypad with 10cm (4in) Read Range

Indoor/Outdoor Proximity Reader and Keypad with 10cm (4in) Read Range Indoor/Outdoor Proximity Reader and Keypad with 10cm (4in) Read Range Stand alone CR-R885-SB Installation and Operating Instructions V1.1 TABLE OF CONTENTS Installation... 2 Mounting and Wiring... 2 Mounting

More information

AC-115 Compact Networked Single-Door Controller Hardware Installation and Programming

AC-115 Compact Networked Single-Door Controller Hardware Installation and Programming AC-115 Compact Networked Single- Controller Hardware Installation and Programming Copyright 2013 by Rosslare. All rights reserved. This manual and the information contained herein are proprietary to REL,

More information

CRC220 and CRC221 INSTALLATION GUIDE. REF No.: DOC0014 ISSUE: 09

CRC220 and CRC221 INSTALLATION GUIDE. REF No.: DOC0014 ISSUE: 09 CRC220 and CRC221 INSTALLATION GUIDE REF No.: DOC0014 ISSUE: 09 30th July 2015 2 Contents CRC220 & CRC221 INSTALLATION GUIDE 1. Scope 1-1 2. Introduction 2-1 2.1 Features 2-1 2.1.1. PCB Features 2-1 2.1.2.

More information

DP2 DOOR PHONE. For Technical Assistance Please Phone: (07)

DP2 DOOR PHONE. For Technical Assistance Please Phone: (07) DP2 DOOR PHONE For Technical Assistance Please Phone: (07) 5596 5128 TABLE OF CONTENTS Description Page 3 Door Phone Dimensions Page 4 Door Phone Range Page 5 Door Phone Performance Page 6 Operation Summary

More information

DP-222Q Color Video Door Phone Manual

DP-222Q Color Video Door Phone Manual DP-222Q Color Video Door Phone Manual * has 6 LEDs for nighttime operation Remotely and securely talk to visitors and unlock doors, gates, etc. from the Easily connect a secondary * Simple 2-wire connection

More information

A0362. Bluetooth 4.2 Receiver Module For Aria Audio System. ARIA Audio

A0362. Bluetooth 4.2 Receiver Module For Aria Audio System. ARIA Audio A0362 Bluetooth 4.2 Receiver Module For Aria Audio System ARIA Audio by 2018 Model A0362 Channel Vision s ARIA Audio Streaming Receiver is equipped with a Blue tooth 4.2 module, users will enjoy further

More information

ADVANTAGE DKE QUICK START GUIDE. 2 Make sure you have everything shown here. 3. What s what? All important internal components labeled for you

ADVANTAGE DKE QUICK START GUIDE. 2 Make sure you have everything shown here. 3. What s what? All important internal components labeled for you 1 of 6 START HERE 1 Carefully unpack box. 2 Make sure you have everything shown here. 3 Unlock and remove front panel of keypad unit, then using carriage bolts and hex nuts, attach unit to pedestal as

More information

Outdoor Stand-Alone Weatherproof Keypads

Outdoor Stand-Alone Weatherproof Keypads Outdo Stand-Alone Weatherproof Keypads Manual (SK-2323-SDQ shown) (SK-1323-SPQ shown) Model Number 2 Relay Outputs Mullion-Style Keypads Backlit Keys Proximity Reader SK-2323-SDQ SK-2323-SPQ Sealed-Environment

More information

FTK5 PROXIMITY KEYPAD

FTK5 PROXIMITY KEYPAD FTK5 PROXIMITY KEYPAD Before using the unit, please read the instructions and retain for future reference 1 There are 600 user codes (fobs or cards) and 1 programming code: Careful administration records

More information

Wiring Inside the card reader you will see a circuit board. The connections are as follows:

Wiring Inside the card reader you will see a circuit board. The connections are as follows: Power Adaptor (12VDC, Max. Current: 1A) If you purchased the Cardlock Series power supply cut the head of the adaptor and strip the insulation. If your locking mechanism, electric strike or magnetic lock

More information

232iLM Keypad Installation & Programming Instructions

232iLM Keypad Installation & Programming Instructions 232iLM Keypad Installation & Programming Instructions Note: This product is designed to be installed and serviced by security and lock industry professionals. Specifications Case Dimensions: 6-1/2 L x

More information

Enterprise Call Manager

Enterprise Call Manager Enterprise Call Manager Installation & Operation Manual Please leave this manual with the unit after installation Enterprise Call Manager Rev 1.7 Draft Rev. 10/11/2001 INTRODUCTION SYSTEM DESCRIPTION The

More information

ENFORCER. SK-1123-SQ Outdoor Digital Access Keypad with 2 Outputs MANUAL. Digital Access Keypad Manual. Also available from SECO-LARM: Outdoor Keypads

ENFORCER. SK-1123-SQ Outdoor Digital Access Keypad with 2 Outputs MANUAL. Digital Access Keypad Manual. Also available from SECO-LARM: Outdoor Keypads Quick Reference Guide. Using the User Codes: A. User codes operate the door (4-8 digits long). Press u u u u B. The key must be pressed also if the keypad is in manual-entry mode. Press u u u u Note: u

More information

DOLXFD1000B. Waterproof Access Control/Reader

DOLXFD1000B. Waterproof Access Control/Reader DOLXFD1000B Waterproof Access Control/Reader INTRODUCTION The DOLXFD1000B is a single- entry multi-function Access Controller with integrated keypad and card reader. It is designed and manufactured to

More information

Carefree-Security. Installation and programming instructions 1050A. Owner s Manual

Carefree-Security. Installation and programming instructions 1050A. Owner s Manual Carefree-Security Heavy Duty Commercial - Industrial Fully Sealed Digital Access Keypad Specially Designed for Gate Operators, Overhead Doors, Specialty Doors & Electric Door Locking Devices SINGLE OR

More information

Installation Instructions 4291 and 4292 Keypads

Installation Instructions 4291 and 4292 Keypads Installation Instructions 4291 and 4292 Keypads A6851J 02/11 Copyright 2011, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the

More information

Installation Manual. GSM-3V/AB & ABK V3.5 (1200 keypad) Wiring. Important Notes: SIM card. Installation

Installation Manual. GSM-3V/AB & ABK V3.5 (1200 keypad) Wiring. Important Notes: SIM card. Installation -V/AB & ABK V.5 (2 ) Important Notes: ) Before you install this equipment, please read this full manual. Installation Manual Wiring 8) Carefully follow the wiring instructions. 2) Before fully installing

More information

INSTRUCTION MANUAL AC-T43 PIEZO-KEYPAD STANDALONE ACCESS CONTROL UNIT. 07/04

INSTRUCTION MANUAL AC-T43 PIEZO-KEYPAD STANDALONE ACCESS CONTROL UNIT.  07/04 INSTRUCTION MANUAL 1 2 3 4 5 6 7 8 9 0 # PIEZO-KEYPAD STANDALONE ACCESS CONTROL UNIT www.rosslaresecurity.com 0706-0960050-00 07/04 Contents INTRODUCTION 4 Technical Specifications 5 Key Features 6 INSTALLATION

More information

WR-5e Remote Control

WR-5e Remote Control 1. Introduction WR-5e Remote Control The WR-5e is a microprocessor based serial data remote control unit for Ashly NE or NX products. Compatible products currently include Pema amplifiers, ne8800 and ne4800

More information

REX F-0-9 Standalone or Access Controller

REX F-0-9 Standalone or Access Controller REX F-0-9 Standalone or Access Controller Power supply The controller need s external power supply to operate. The Spider W40 power supply is sufficient to power two controllers and two 12V electric strikes

More information

Ashly WR-5 Remote Control

Ashly WR-5 Remote Control 1. Introduction Ashly WR-5 Remote Control The WR-5 is a microprocessor based serial data remote control unit for Ashly NE or NX products. Compatible products currently include Pema amplifiers, ne8800 and

More information

HL100 Fingerprint Lock User Manual

HL100 Fingerprint Lock User Manual HL100 Fingerprint Lock User Manual Version: 1.0 About This Manual This manual introduces the fingerprint lock interface and menu operations for the HL100. For the fingerprint lock installation, see the

More information

SL2000E. Status Output. Electronic Code Lock. Features. Input. Exit Button Input. Introduction. Door Contact Input. Functional Description.

SL2000E. Status Output. Electronic Code Lock. Features. Input. Exit Button Input. Introduction. Door Contact Input. Functional Description. SL2000E Electronic Code Lock Features Door Relay output Status transistor output Aux transistor output Door Contact input Exit Button input INSTALLER code for programming MASTER code for arming/disarming

More information

Partizan PAB-FC2. Fingerprint scan time Fingerprint identification time. <0.5 s < % <0.0198% Ingress protection rating

Partizan PAB-FC2. Fingerprint scan time Fingerprint identification time. <0.5 s < % <0.0198% Ingress protection rating 1. Features & Technical Parameters 1.1 Features: Partizan PAB-FC2 Metal vandalproof housing Secure and reliable biometric fingerprint recognition Simple for using, wiring can be done by a user without

More information

DP-222Q Color Video Door Phone Manual

DP-222Q Color Video Door Phone Manual DP-222Q Color Video Door Phone Manual * has 6 LEDs for nighttime operation Remotely and securely talk to visitors and unlock doors, gates, etc. from the Easily connect an secondary * Simple 2-wire connection

More information

DP-234Q (NTSC) DP-734Q (PAL) Hands-Free Video Door Phone Manual

DP-234Q (NTSC) DP-734Q (PAL) Hands-Free Video Door Phone Manual DP-234Q (NTSC) DP-734Q (PAL) Hands-Free Video Door Phone Manual Screen image simulated. * has four LEDs for nighttime operation Remotely and securely talk to visitors and unlock doors, gates, etc. from

More information

MULTI-PURPOSE SELF-CONTAINED DIGITAL ACCESS CONTROL KEYPAD

MULTI-PURPOSE SELF-CONTAINED DIGITAL ACCESS CONTROL KEYPAD MULTI-PURPOSE SELF-CONTAINED DIGITAL ACCESS CONTROL PAD Programming & Installation Manual An Innovative Product Developed By: PROTECT - ON SYSTEMS LTD. MANUFACTURED BY: 20 R SINCE 1979 ADVANCED ELECTRONICS

More information

Stand-Alone Data Chip System

Stand-Alone Data Chip System Stand-Alone Data Chip System OVERVIEW This Data Chip System supports up to 17 users and each user can be added or deleted in a matter of seconds. This System can be used in a variety of Security and Access

More information

AirTest Model CN9000 Series Sensor Controller

AirTest Model CN9000 Series Sensor Controller AirTest Model CN9000 Series Sensor Controller AirTest Model CN9000 Series Sensor Controller THEORY OF OPERATION A basic CN9000 configuration consists of Input/Process/Display combination modules, a 3 relay

More information

Waterproof. Keypad/Reader/Controller

Waterproof. Keypad/Reader/Controller Waterproof Keypad/Reader/Controller User Manual W1-C W3-C User manual 1. Packing List Name Quantity Remarks Digital Keypad-W1-C/W3-C 1 User manual 1 Screw driver 1 Rubber bungs 4 6*27mm, used for fixing

More information

DG Series. Access Control Proximity Readers DG-160 DG-800

DG Series. Access Control Proximity Readers DG-160 DG-800 DG Series Access Control Proximity Readers DG-800 + DG-160 + Features: Applicable card modeem Card / Key Fob 1 Administrator and 200 Users 200 Proximity Cards / Key fobs Access ModesUse Bluetooth smartphone,

More information

ROSSLARE AC-115. Hardware Installation and User s Guide DOOR MODE 10/01

ROSSLARE AC-115. Hardware Installation and User s Guide DOOR MODE 10/01 ROSSLARE MODE 1 2 DOOR 3 4 5 6 7 8 9 0 # AC-115 Hardware Installation and User s Guide 10/01 ROSSLARE Hardware Installation and User s Guide for the AC-115 Access Control System MODE 1 2 DOOR 3 4 5 6 7

More information

Security Door Controls

Security Door Controls Security Door Controls 3580 Willow Lane, Westlake Village, CA 91361-4921 (805) 494-0622 Fax: (805) 494-8861 www.sdcsecurity.com E-mail: service@sdcsecurity.com PROGRAMMING INSTRUCTIONS E72K-A CIVIC SERIES

More information

User/Installation Manual

User/Installation Manual User/Installation Manual ADVANTAGE DKLP MODEL 19-100(i) Your Partner in Access Control www.americanaccess.com AAS 2Year Limited Warranty What item(s) this warranty applies to: American Access Systems DKLP

More information

RV LEVELING SYSTEM AUTO LEVEL SYSTEM WARNING! FAILURE TO ACT IN ACCORDANCE WITH THE FOLLOWING MAY RESULT IN SERIOUS PERSONAL INJURY OR DEATH.

RV LEVELING SYSTEM AUTO LEVEL SYSTEM WARNING! FAILURE TO ACT IN ACCORDANCE WITH THE FOLLOWING MAY RESULT IN SERIOUS PERSONAL INJURY OR DEATH. RV LEVELING SYSTEM AUTO LEVEL SYSTEM WARNING! FAILURE TO ACT IN ACCORDANCE WITH THE FOLLOWING MAY RESULT IN SERIOUS PERSONAL INJURY OR DEATH. THE USE OF THE GROUND CONTROL AUTO LEVELING SYSTEM TO SUPPORT

More information

Operating Instructions KEYPAD. Compatible WIRELESS ACCESS CONTROL

Operating Instructions KEYPAD. Compatible WIRELESS ACCESS CONTROL Operating Instructions KEYPAD Compatible WIRELESS ACCESS CONTROL Contents Technical specifications page 1 Approvals page 1 Changing the Master code page 2 Adding a User code page 3 Deleting a User code

More information

AlphaStatus Room Status System Installation and Use Instructions for the RSS400 Series Room Stations and Optional Master Station(s)

AlphaStatus Room Status System Installation and Use Instructions for the RSS400 Series Room Stations and Optional Master Station(s) AlphaStatus Room Status System Installation and Use Instructions for the RSS400 Series Room Stations and Optional Master Station(s) APPLICATION The AlphaStatus system allows one or more RSS402, RSS403,

More information