DATA LOGGER GEOLOGGER G8 PLUS

Size: px
Start display at page:

Download "DATA LOGGER GEOLOGGER G8 PLUS"

Transcription

1 A D V A C E D DATA LOGGER GEOLOGGER G8 PLUS I N S T CONFIGURATION & WIRING OF PERIPHERALS R U C T I O N M A N U A L 1

2 CONTENTS DESCRIPTION PAGE Main components 3 G8 Module Connections 4 G8 Module Connections (bottom side) 5 G8 Module connections (top side) 6 Mains powered schematic wiring diagram 7 SmartMux ID setup 8 Rebooting a SmartMux 9 Digital SmartMux overview 10 Analogue SmartMux inputs 11 Wiring options to analogue SmartMux 12 Grounding the VW sensor shield wire to analogue SmartMux 13 Grounding the G8 and/or Remote SmartMux 14 G8 to analogue SmartMux system configurations 15 Typical wiring between G8 & analogue SmartMux (G8 at start of chain) 16 Typical wiring between G8 & analogue SmartMux (G8 in middle of chain) 17 G8 to analogue SmartMux connections (RS232) 18 Router/modem setup 19 G8 as a Web Server 20 G8 as an FTP server 21 G8 configuration 22 2

3 Main Components Central processing unit (CPU) G8 Module to which all the components are linked. SmartMux (Analogue / Digital): A smart relay mechanism controlled by the CPU to switch between multiple sensors so that they can be monitored by a single CPU. Allows multi sensors to be fed into the measurement & control module. Power Supplies: A power supply provides regulated power to the logger and sensors. 12 volt DC fed either by 220 volt mains adaptor and charger with 12 Volt DC battery back up, 12 Volt DC battery with solar panel. Communication: Remote or local connection to the CPU to program or download data including GSM, GPRS, radio and cable. Enclosure - which houses all the above components mounted, pre-wired and preprogramed in a robust IP65 enclosure for mounting on a suitable location such as a wall or support frame. Barometer - for compensation due to changes in barometric pressure for sensors used for pressure monitoring. (Not shown). 3

4 G8 Module Connections 2X OPTIONAL DEVICE TO G8 ALERT INPUTS 2X OPTIONAL G8 TO DEVICE POWER OUTPUTS RS485a DIGITAL DEVICE TO G8 INPUT / OUTPUT RS485b DIGITAL DEVICE TO G8 INPUT / OUTPUT FOR RADIO INTEGRATED SYSTEMS ONLY SD CARD SLOT FOR DATA BACKUP LAN PORT FOR NETWORK TO G8 DIRECT CONNECTION OR G8 TO MODEM LINK RS232b ANALOGUE INPUT / OUTPUT RS232a ANALOGUE INPUT / OUTPUT USB PORT FOR DATA BACKUP POWER INPUT AND SWITCH ON OFF DIGITAL IN 1 LOCAL DIGITAL DEVICE TO G8 INPUT DIGITAL IN 0 LOCAL DIGITAL DEVICE TO G8 INPUT ANALOG IN 0 LOCAL ANALOGUE DEVICE TO G8 INPUT ANALOG IN 1 LOCAL ANALOGUE DEVICE TO G8 INPUT Remember to insert the SD card with the metal contacts facing UP 4

5 G8 Module Connections (bottom side) +5V/ +12V Radio Tx Rx COM A separate module is required for radio outputs RS485a (#1) RS485b (#1) COM B A +12V COM B A +12V COM +12V [1] 120Ω Termination Resistor Siren Horn Light Power OUT Modem, Mux Digital Sensor Digital Bus Analogue Mux Digital Mux [2] Not used - always have DOWN 5

6 G8 Module Connections (top side) USB Port for data backup Trigger Pulse Counter Analogue Input V 0-3V 4-20mA COM SGLC mv/v???? Channel can receive single ended voltage signal 6

7 Mains Powered G8 Enclosure Schematic Wiring Diagram Antenna 240V - 12V Transformer Battery Fuse Radio G8 Module Modem Fuse EMC filter SmartMux MAINS IN SENSORS IN 7

8 SmartMux ID Setup SmartMux IDs are determined by the use of mini dipswitches at the front of each unit. These are usually preconfigured before you receive them, according to your system design. MUX ID 1 MUX ID 10 MUX ID 20 MUX ID 30 The setup is based on zero index binary, with the least significate bit at the front. Examples: 1 in binary is ; on the mux it will be in binary is ; on the mux it will be WHY back to front?! [1] RS232/RS485 Switch - DOWN for RS485 [1] Not used - always have DOWN [2] Not for customer use - always have DOWN [2] 120Ω Termination Resistor - only have UP when at the end of the string 8

9 Rebooting a SmartMux Reboot Mode Rebooting the SmartMux will cause it to lose it s memory and it will then be able to communicate with a new G8 1. In the middle block of dipswitches, push all 1-8 up A SmartMux will memorise the name of the first G8 it communicates with and will only communicate with that G8 from then on. If the G8 ID is changed, the mux will not communicate with it. A sign that this is happening is that the data file states NO-RX where there should be data. In addition to this, the red light on the SmartMux will not flash, only the green light will come on (the SmartMux will take a reading but it will not send it to the G8) 2. Supply power to the mux. The easiest way to do this is by creating a local reading of that mux (any channel) The red and green LED lights on the front of the mux will flash alternately 3. After the lights begin to flash, press ESC repeatedly until the flashing stops 4. Rename your SmartMux by changing the dipswitches back to their original configuration 5. Take a local reading from the SmartMux to confirm that you get a response 9

10 RS-485 Incorporating a Digital SmartMux (DMUX) with Analogue SmartMuxs (GMUX) Channel 1 Channel 2 Channel 3 Channel 4 Channel 5 Channel 6 Channel 7 Channel 8 Channel 16 GMUX ID0003 RS-485 Channel 1 GMUX ID0004 Channel 1 Channel 2 Channel 3 Channel 4 Channel 5 Channel 6 Channel 7 Channel 8 Channel 16 Channel 1 Channel 2 Channel 3 Channel 4 Channel 5 Channel 6 Channel 7 Channel 8 Channel 16 GMUX ID0002 Channel 2 GMUX ID0005 Channel 1 Channel 2 Channel 3 Channel 4 Channel 5 Channel 6 Channel 7 Channel 8 Channel 16 Channel 1 Channel 2 Channel 3 Channel 4 Channel 5 Channel 6 Channel 7 Channel 8 Channel 16 GMUX ID0001 NOTE Digital & analogue SmartMuxs can be connected together within a chain Channel 3 GMUX ID0006 Channel 1 Channel 2 Channel 3 Channel 4 Channel 5 Channel 6 Channel 7 Channel 8 Channel 16 The digital SmartMux MUST BE at the end of the RS485 line The digital SmartMux only has one ID per channel so you can either connect one digital sensor (or string of digital sensors) or an analogue SmartMux into each channel Each channel can take one RS-485 digital input Channel 4 GMUX ID0007 Channel 1 Channel 2 Channel 3 Channel 4 Channel 5 Channel 6 Channel 7 Channel 8 Channel 16 G8 10

11 Analogue Smart Mux inputs TOP mv/v Sensors 4-20mA Sensors VW +Temp Sensors BOTTOM G8 RS485a/b RS232 (For Radio Module) +V In GND EXTERNAL POWER SUPPLY 11

12 Wiring Options to Analogue Smart Mux 4-20mA output Uniaxial Tilt x2 No temperature Channel 13 Sensor Channel 14 Sensor Channel 15 Sensor Channel 16 Sensor Channel 9 Sensor Channel 10 Sensor Channel 11 Sensor Channel 12 Sensor 4-20mA output Biaxial Tilt No temperature Channel 5 Sensor Channel 6 Sensor Channel 7 Sensor Channel 8 Sensor VWSG Voltage output Uniaxial Tilt No temperature Channel 1 Sensor Channel 2 Sensor Channel 3 Sensor Channel 4 Sensor PT100 R232 +V Out TxD RxD GND Vibrating wire output With temperature PT100 VW Load Cell (6 sensors) More wiring options VWP 12

13 RS485 GND GND GND Grounding the VW Sensor Shield Wires to the Analogue Smart Mux Reduce the effects of electronic interference by grounding the sensor cables to the GND ports on the right side of the mux RS Typical data from a mains powered system where the shield wires from the sensors have not been connected to the multiplexer 13

14 Grounding the G8 and/or Remote SmartMux The return of the battery provides the ground - + BATTERY G8 Common ground connects any mux to the G8 M1 M2 Twisted pair provides A & B signals whilst cancelling out noise. Signal ground is therefore not required Mains power has it s own earth cable You can connect the enclosure the physical earth especially in areas common to lightning strikes M3 Remote mux enclosure is connected to an earth ground cable or to a bus bar 14

15 G8 to Analogue Smart Mux System Configurations 1. Mux - G8 - Mux - Mux (n) Mux Mux at the end of the string RESISTOR ON G8 within the string, not at the beginning or end: RESISTOR OFF RESISTOR OFF RESISTOR OFF Mux at the end of the string RESISTOR ON 2. G8 - Mux - Mux - Mux (n) Mux G8 at the beginning of the string: RESISTOR ON RESISTOR OFF RESISTOR OFF RESISTOR OFF Mux at the end of the string RESISTOR ON 15

16 COM B A 12V COM B A +12V COM B A +12V Typical Wiring between G8 and Analogue Smart Mux Configuration G8 at the start of the chain G8 RS485b COM B A +12V REMOTE SMARTMUX yyyyy RS REMOTE SMARTMUX xxxxx RS485 REMOTE SMARTMUX zzzzz RS485 Enclosure Enclosure 2 16

17 COM B A 12V COM B A +12V COM B A +12V Typical Wiring between G8 and Analogue Remote Smart Mux Configuration G8 in the middle of a chain RS485a RS485b COM B A +12V COM B A +12V Enclosure 1 REMOTE SMARTMUX yyyyy RS REMOTE SMARTMUX xxxxx RS485 REMOTE SMARTMUX zzzzz RS Enclosure 2 Enclosure 3 17

18 G8 to Analogue Smart Mux Connections (RS232) Useful if the two RS485 ports are already in use The RS232 connection on the Mux is not designed for a direct connection from the G8 to a Mux. To connect the G8 to a Mux using the RS232 ports on the G8, you must use an RS232 - RS485 converter to change an analogue signal into a digital signal. You would then connect to the Mux using the RS485 connector block The RS232 connection on the mux is used for radio connections Supplying Mux String 1 Supplying Mux String 2 RS232 - RS485 Signal Converter RS232 - USB Type B Cable V A+ B- GND RS485 IN RS485 OUT RS232 IN Example system using a signal converter RS232 OUT String 1 GMUX 1 String 1 GMUX 2 String 1 GMUX 3 String 1 GMUX 4 Signal Converter analogue G8 String 2 GMUX 1 String 2 GMUX 2 String 2 GMUX 3 String 2 GMUX 4 digital String 3 GMUX 1 String 3 GMUX 2 String 3 GMUX 3 String 3 GMUX 4 18

19 Router/Modem Setup Parts of the standard router Mains supply: 2 pin plug provided Antenna: Required for GSM connection. The modem will not work without this, or another SMA antenna connected LAN Cable: Connect your PC to the Modem for initial setup, and then to connect the modem to the G8 The Router SIM Card Slot: SIM card is placed chip side up Antenna Connector LAN Port: Plug in your LAN cable here to connect via G8 or PC Power In 19

20 Router/Modem Setup Powering the router When installed in an enclosure like this, the router can be powered by the G8 itself using the MOD1/2 connectors When powered AND connected, the router lights will look like this, with the S1 light flashing 20

21 Router/Modem Setup Accessing the router network To configure the router, you must directly connect to it using your PC & the LAN cable. Then you must change your PC IP to match the network of the modem Configuration PC 1. Using the Network and Sharing Centre, go to the properties of the Local Connection (sometimes you must go to change adapter settings) 2. Select properties You will need an administrator username and password for this Router In - situ G8 Router 3. Double click on Internet Protocol Version 4 (TCP/IPv4) 4. Use the same IP address as on the router but change the last number You will then be on the same network as the router and be able to communicate 21

22 Router/Modem Setup Configuring the router 1. Configure your PC to be on the same network as the router 2. Using a web browser, type in the IP address stated on the label of the router 3. Use the password stated on the label Red = disconnected/no signal Green = signal available Local Network Confirm the IP address of the modem TCP/IP Forwarding The IP address must be that of the G8. Any message coming to the stated ports will be directed to this IP address GSM Network Insert the SIM cards APN details here 22

23 The G8 as a Web Server Controlling the G8 remotely (data not accessible except for local acquisitions) Geosense issued SIM Card numbers and IP addresses can be found: \\geohost1\company-g\administration\monthly FEES\SIM CARDS Type the public IP address of the SIM card into the web browser, preset username = admin, password = 1234 (these can be changed within the G8 setup). The webserver home page will show the logger ID, number of outputs and alarms and the time. Local inputs give G8 local readings LAN Config provides G8 IP address Remote allows you to control the keypad of the G8 23

24 The G8 as an FTP Server Accessing the G8 files remotely Download an FTP client such as Filezilla and connect to the G8 by inputting the host details: - Download FileZilla Client General: Host = SIM IP address User and Password is the same as your remote access username and password, usually admin & 1234 Transfer Settings: The transfer mode must be Active. With the number of simultaneous connections limited to 1 G8 connection status Disconnect Cancel Refresh Files on your PC select a location where you would like the downloaded files to be saved Files within the G8 Select a location where you want to download the files from. Double click to download Warning Download status Shows if downloads are queued, successful or failed This system also allows you to add files from your PC into the G8 so be careful where you click! 24

25 G8 Configuration G8 Logger Setup CONFIGURATION G8 LOGGER SETUP ID NUMBER MODULES SUPPLY MODULE 1 SUPPLY OFF ON DURING ACQ PLANNED ON ALWAYS ON DAILY SWITCH ON HOURLY SWITCH ON Modem or alarm power supply controls MODULE 2 SUPPLY AS PER MODULE 1 SUPPLY RADIO MODULE ANALOGUE INPUTS ADC0 NONE 4/20mA 0-3V For sensors directly connected to the G8, no mux involved 0-10V ADC1 AS PER ADC0 DIGITAL INPUTS DIG0 NONE TRIGGER PULSE COUNTER FREQUENCY INPUT DIG1 AS PER DIG0

26 CONFIGURATION G8 LOGGER SETUP SET DATE/TIME YY > MM> DD> HH > MM LAN CONFIG SD CARD EXPLORER MANUAL LAN CONFIG DHCP A:/ This is the IP address of the logger itself MUMS MUX SYSTEM >1 SYS CAL CONF These are the same folders that you can see on an FTP Client. You can remove the SD card from the G8 to access these folders as well DATA DMUX IPTM

27 CONFIGURATION G8 LOGGER SETUP ADVANCED TOOLS SYSTEM BACKUP DATA BACKUP BACKUP RATE USB BACKUP POWER MODE FULL FUNCTIONS MIDNIGHT RESET LOW POWER MODE MODULE 1 SUPPLY OFF ON DURING ACQ PLANNED ON DAILY SWITCH ON HOURLY SWITCH ON ALWAYS ON MODULE 2 SUPPLY AS PER MODULE 1 SUPPLY RADIO MODULE ULTRA LOW POWER CONFIGURATION G8 LOGGER SETUP ADVANCED TOOLS FTP CLIENT MODE SET NOT USED SET FTP CONFIG. SET FTP RATE SET FTP SUPPLY NONE MOD1 TX FTP TEST FTP MAIL NOTIFY SERVER FILES NAME MOD2 DATA FILES TEST FILE LEAVE ORIGINAL RENAME FILES Send a data packet to the designated location on the server

28 CONFIGURATION G8 LOGGER SETUP ADVANCED TOOLS ALARMS ALARM THRESHOLDS VIEW LIMIT VIEW/EDIT LIMIT DELETE LIMIT DELETE ALL LIMITS SENDER MAIL RECEIVERS MAILS NOTIFICATION LIST VIEW EDIT APPEND NEW (ERASE ALL) WARNING LIST VIEW EDIT APPEND NEW (ERASE ALL) ALARM LIST VIEW EDIT APPEND NEW (ERASE ALL) ALARM OUTPUTS TEST ALARM OUTPUT 1 ON/OFF ALARM OUTPUT 2 ON/OFF ALARM MAIL TEST TEST OPTION ONLY

29 CONFIGURATION G8 LOGGER SETUP SYSTEM INFO NEW (ERASE OLD) VIEW PIN SECURITY SET/CHANGE PIN REMOVE PIN EXPERT MENU DEV EEPROM IM/EXP READ FROM DEVICE WRITE TO DEVICE DEV FW UPGRADE IP PING RADIO TOOLS REBOOT CALIBRATION TASKS USAGE RADIO NODES LIST RADION DEVICES LIST DELETE RADIO LIST BATTERY VOLTAGE TEMPERATURE Test connection integrity by pinging the Google server CONFIGURATION DEVICES CONFIG GMUX CONFIGURATION VIEW MUX NEW/EDIT MUX RS485a OFF ON DURING ACQ RS485b RS232a RS232b WIRELESS OFF ON DURING ACQ Select what signal the G8 must use to communicate DELETE MUX DELETE ALL MUX DMUX CONFIGURATION VIEW MUX NEW/EDIT MUX DELETE MUX DELETE ALL MUX

30 CONFIGURATION DEVICES CONFIG MUMS CONFIGURATION VIEW MUMS NEW/EDIT MUMS RS485a RS485b RS232a RS232b WIRELESS DELETE MUMS DELETE ALL MUMS IPTM CONFIGURATION VIEW IPTM NEW/DIT IPTM RS485a RS485b RS232a RS232b WIRELESS DELETE IPTM DELETE ALL IPTM ACQUISITIONS NEW DATA ACQUISITION APPEND DATA ACQUISITION Create a new data acquisition and backup existing data files Append to existing data files LOCAL ACQUISITION LOCAL CHANNELS GDATA LOCAL ACQUISITION MUX LOCAL ACQUISITION MUMS LOCAL ACQUISITION IPTM LOCAL ACQUISITION Read battery voltage and logger temperature Read data from sensors directly connected to the G8 Read data from sensors connected to the multiplexers Read the tilt array Read the digital string STOP/START ACQUISITION

G801 Digital and Interconnection Logging Module for managing of monitoring systems. MAIN FIELDS OF APPLICATION

G801 Digital and Interconnection Logging Module for managing of monitoring systems. MAIN FIELDS OF APPLICATION re a d o u t l o g g e r u n i t G801 Digital and Interconnection Logging Module for managing of monitoring systems. MAIN FIELDS OF APPLICATION - Geotechnical engineering - Hydrology - Meteorology G801_eng_1.0.2

More information

SMART MUX INTERFACE (SMI)

SMART MUX INTERFACE (SMI) SMART MUX INTERFACE (SMI) I N S T R U C T I O N M A N U A L 2 CONTENTS Page 1.0 INTRODUCTION 1 1.1 General Description 1 1.2 Device Compatibility 2 1.3 Theory of Operation 3 2.0 CONFORMITY 5 3.0 MARKINGS

More information

and/or b. an optional internal Iridium satellite modem.

and/or b. an optional internal Iridium satellite modem. Appendix D Manual for Data Logger/Control Unit D.1. Introduction and Specifications D.1.1. Q DL 2100 Data logger Platform The Q DL 2100 data logger platform consists of: 1. A microcontroller containing

More information

USER MANUAL FOR GS100/GS1003G

USER MANUAL FOR GS100/GS1003G USER MANUAL FOR GS100/GS1003G 1 Table of Contents 1. INTRODUCTION... 3 2. FEATURES... 3 3. OPERATION... 3 4.CONNECTION DETAILS... 4 5.CONFIGURATION... 5 5.1 Hyper Terminal Setting... 5 5.2 GS100 Configuration...

More information

User Manual. cmt-svr Startup Guide

User Manual. cmt-svr Startup Guide User Manual cmt-svr Startup Guide Table of Contents Chapter 1 Overview... 1 1.1 Specification... 1 1.2 Dimensions... 2 1.3 Connector pin designations... 3 1.4 USB host port and SD card slot... 3 1.5 Ethernet

More information

FAST Installation (PMRS) Box Contents

FAST Installation (PMRS) Box Contents FAST Installation (PMRS) Box Contents PMRS Unit Video/Power Adapter GPS Antenna 5V Charger u USB Cable 12V 5V Car Adapter PTZ+GPIO Cable Voice splitter GSM Antenna (Optional) LAN Cable Required Items SIM

More information

R O U T E R М Т 0 1 V e r s i o n v А Т O M e v e r i t h i n g n e w e m e r g e s n o w

R O U T E R М Т 0 1 V e r s i o n v А Т O M e v e r i t h i n g n e w e m e r g e s n o w ROUTER МТ01 V e r s i o n v 1. 0 0 5. 2 0 1 5 А Т. 6 8 7 4 2 2. 0 5 2 O M e v e r i t h i n g n e w e m e r g e s n o w Table of Contents 1. Product designation... 3 2. Complete set of supply... 4 3. МТ01

More information

Installation and Configuration Quick Guide R3000. Industrial Dual SIM Cellular VPN Router 2 Eth + 1 RS RS USB Host.

Installation and Configuration Quick Guide R3000. Industrial Dual SIM Cellular VPN Router 2 Eth + 1 RS RS USB Host. Package Contents Installation and Configuration Quick Guide Before installing your R3000 Router, verify the kit contents as following. 1 x Robustel R3000 Industrial Dual SIM Cellular VPN Router (GPS/WiFi

More information

Quick Start Guide. Preparation. Installation. Operation. Support. Vaisala NOMAD 3 Data Logger. Online manuals

Quick Start Guide. Preparation. Installation. Operation. Support. Vaisala NOMAD 3 Data Logger. Online manuals Quick Start Guide www.vaisala.com Vaisala NOMAD 3 Data Logger Preparation Package Contents Plan Instrumentation Create a SkyServe Account Activating the Nomad 3 Nomad 3 Toolbox Create Setup Files 2 4 5

More information

Dupline. Data Logger. Types G , G Product Description. Ordering Key G Type Selection. Input/Output Specifications

Dupline. Data Logger. Types G , G Product Description. Ordering Key G Type Selection. Input/Output Specifications Dupline Data Logger Types G 800 006, G 800 106 Product Description Programmable channel generator with optional built-in GSM Modem Event and time based data logging functions for digital, analog and counter

More information

G-LOG Mobile Application

G-LOG Mobile Application G-LOG Mobile Application I N S T R U C T I O N M A N U A L Version 1.0.12 February 2015 CONTENTS 1. ABOUT THIS DOCUMENT... 3 2. INITIAL STEPS... 3 2.1. App installation... 3 2.2. Connection... 3 2.3. Power...

More information

RM6000 GPRS Modem / Router

RM6000 GPRS Modem / Router User Manual Version 6.30 AMG Systems Ltd March 2013 3 The Omega Centre Stratton Business Park Biggleswade Bedfordshire, UK SG18 8QB Tel: 44 (0) 1767 600777 sales@amgsystems.com 1. Introduction 2. RM6000

More information

Instructions Industrial 4G Router R700 - firmware version B Quick and easy setup of the Industrial 4G Router type R700

Instructions Industrial 4G Router R700 - firmware version B Quick and easy setup of the Industrial 4G Router type R700 Quick and easy setup of the Industrial 4G Router type R700 Preparation - Disable the pin code of the sim card (in a mobile phone) - Keep the APN data with you. The APN data is required for setting up the

More information

Installation and Configuration Quick Guide. R3000 Lite. Industrial Dual SIM Cellular VPN Router (1 Eth + 1 RS RS USB Host)

Installation and Configuration Quick Guide. R3000 Lite. Industrial Dual SIM Cellular VPN Router (1 Eth + 1 RS RS USB Host) Package Contents Before installing your R3000 Lite Router, please verify the kit contents as following. 1 x Robustel R3000 Lite Industrial Dual SIM Cellular VPN Router 1 x 3-pin pluggable terminal block

More information

INDEX. Network Power Monitor NPM-R10-SNMP. Innovative Electronics for a Changing World. NPM-R10-SNMP Remote Network Power Monitor

INDEX. Network Power Monitor NPM-R10-SNMP. Innovative Electronics for a Changing World. NPM-R10-SNMP Remote Network Power Monitor Innovative Electronics for a Changing World NPM-R10-SNMP Remote Network Power Monitor Optional relay board and GSM module INDEX 1. SYSTEM DESCRIPTION 2. SYSTEM BATTERY CONNECTIONS 3. SERIES CONNECTED BATTERIES

More information

Installation and Configuration Quick Guide R2000. Industrial Dual SIM Cellular VPN Router (2 Eth + 2 SIM) Package Contents

Installation and Configuration Quick Guide R2000. Industrial Dual SIM Cellular VPN Router (2 Eth + 2 SIM) Package Contents Package Contents Before installing your R2000 Router, please verify the kit contents as following. 1 x Robustel R2000 Industrial Dual SIM Cellular VPN Router 1 x 3-pin 3.5 mm male terminal block for power

More information

256 MB RAM. 256 MB 32 bits RISC Cortex-A8 600MHz SD Card Slot. N/A USB Host. N/A USB Client

256 MB RAM. 256 MB 32 bits RISC Cortex-A8 600MHz SD Card Slot. N/A USB Host. N/A USB Client User Manual V1.0.0 Table of Contents Overview... 1 1.1. Specification... 1 1.2. Dimensions... 2 1.3. Connector pinouts... 3 1.4. Restoring factory default... 3 1.5. LED indicator... 3 1.6. CR1225 battery...

More information

Technical User Manual Avisaro 4.0 Product Series

Technical User Manual Avisaro 4.0 Product Series Technical User Manual Avisaro 4.0 Product Series including PC Companion Software RS232 CAN 4..20mA Analog Version / Date 2019-01-11 1. TABLE OF CONTENT Hint: Use key with mouse click within the

More information

EA500. Installation Instructions Transponder

EA500. Installation Instructions Transponder EA500 EN Installation Instructions Transponder EA500 Installation Instructions 1.0 Overview EN 2 1.0 Overview The EA500 Transponder is the Security Escort module that provides communications between the

More information

mini CRD OMNIA _ MINI OMNIALOG READOUT UNITS AND DATALOGGERS

mini CRD OMNIA _ MINI OMNIALOG READOUT UNITS AND DATALOGGERS CRD _ MINI LOG READOUT UNITS AND DATALOGGERS MINI _EN_06_06/2016 mini log Mini log is a four-channel logger that can be factory-configured to read specific types of sensors: it reads analog (current, voltage,

More information

F Series Indoor Fixed IP Camera. Quick Start Guide

F Series Indoor Fixed IP Camera. Quick Start Guide F Series Indoor Fixed IP Camera Quick Start Guide Welcome Thank you for purchasing our IP camera! Before install and use the IP camera, please read the following section carefully. Please keep this start

More information

Installation and Configuration Quick Guide. R3000 Quad. Industrial Cellular VPN Router with 4 Ethernet Ports (4 Eth + 1 RS-232/1 RS USB Host)

Installation and Configuration Quick Guide. R3000 Quad. Industrial Cellular VPN Router with 4 Ethernet Ports (4 Eth + 1 RS-232/1 RS USB Host) Package Contents Before installing your R3000 Quad Router, please verify the kit contents as following. 1 x Robustel GoRugged R3000 Quad Industrial Dual SIM Cellular VPN Router with 4 Ethernet Ports 1

More information

Contents 1 Warnings, Cautions, and Notes Description Features... 1

Contents 1 Warnings, Cautions, and Notes Description Features... 1 EnCell Contents 1 Warnings, Cautions, and Notes... 1 2 Description... 1 3 Features... 1 3.1 STANDARD FEATURES... 1 3.2 FRONT PANEL FEATURES... 2 3.2.1 Display... 2 3.2.2 OK LED... 2 3.2.3 FAULT LED...

More information

RTU560 Connections and Settings DIN Rail RTU 560CIG10

RTU560 Connections and Settings DIN Rail RTU 560CIG10 Connections and Settings DIN Rail RTU 560CIG10 Application, characteristics and technical data have to be taken from the hardware data sheet: 560CIG10 1KGT 150 719 Operation The 560CIG10 is a DIN rail

More information

User Manual. cmt-svr Startup Guide

User Manual. cmt-svr Startup Guide User Manual cmt-svr Startup Guide Table of Contents Chapter 1 Overview... 1 1.1 Specification... 1 1.2 Dimensions... 2 1.3 Connector pin designations... 3 1.4 USB host port and SD card slot... 3 1.5 Ethernet

More information

Docking Station DS-U4WEB with web server version 1 Instruction Manual

Docking Station DS-U4WEB with web server version 1 Instruction Manual Page 1 of 15 Docking Station DS-U4WEB with web server version 1 Page 2 of 15 Table of contents 1 Overview... 3 2 Description... 3 2.1 Connector identification... 3 2.2 Probe inputs... 4 2.3 Logical inputs

More information

CABINET OMNIALOG DATA ACQUISITION SYSTEMS OMNIACABXX FEATURES

CABINET OMNIALOG DATA ACQUISITION SYSTEMS OMNIACABXX FEATURES CABINET OMNIALOG OMNIAlog systems are designed and assembled around OMNIAlog modules. They are the right solution in every project that requires automatic data acquisition, pushing data on ftp, remote

More information

Expansion Module HZS 541-1S

Expansion Module HZS 541-1S Expansion Module HZS 541-1S 12.10.2015 Page 1 System Description The external HZS 541-1S expansion module provides users of biomass heating systems with additional 230 V AC relay outputs, analog inputs

More information

WE CONNECT REAL WORLD STRUCTURAL MONITORING SMART SENSORS SOFTWARE CLOUD WIRELESS INTERFACE TO THE

WE CONNECT REAL WORLD STRUCTURAL MONITORING SMART SENSORS SOFTWARE CLOUD WIRELESS INTERFACE TO THE WE CONNECT REAL WORLD TO THE STRUCTURAL MONITORING SENSORS WIRELESS INTERFACE SOFTWARE CLOUD Rev.10 del 3/10/017 Redatto da: R&D e MKT Approvato da: CEO Smart structural WIRELESS Interface NI00 devices

More information

GC 055. GSM Remote Monitoring. Operating and installation instructions

GC 055. GSM Remote Monitoring. Operating and installation instructions GSM Remote Monitoring Operating and installation instructions GC 055 GSM, GPRS Programmable Communicator Transmits input conditions/controls outputs Measures analogue data Access control system/dallas

More information

QUICK GUIDE for 4 modules. Installation

QUICK GUIDE for 4 modules. Installation QUICK GUIDE for 4 modules Installation 1. Prepare a SIM card so that the PIN code is 1234 or is deactivated. Mount the card in the unit. The unit has now 1234 as password or runs without a password. The

More information

Vibrating Wire Instrument Assembly Guide

Vibrating Wire Instrument Assembly Guide Vibrating Wire Instrument Assembly Guide Geotechnical Instrumentation Introduction The following document shows the various instruments and their part numbers used in the assembly of the different size

More information

Quick Start Guide. GV-Video Server. 1 Introduction. Packing List

Quick Start Guide. GV-Video Server. 1 Introduction. Packing List Introduction Quick Start Guide GV-Video Server Welcome to the GV-Video Server Quick Start Guide. In the following sections, you will learn about the basic installations and configurations of the GV-Video

More information

mini CRD OMNIA _ MINI OMNIALOG READOUT UNITS AND DATALOGGERS

mini CRD OMNIA _ MINI OMNIALOG READOUT UNITS AND DATALOGGERS CRD _ MINI LOG READOUT UNITS AND DATALOGGERS MINI _EN_07_02/2018 MINI LOG Mini log is a four-channel logger that can be factory-configured to read specific types of sensors: it reads analog (current, voltage,

More information

Industrial Serial Device Server

Industrial Serial Device Server 1. Quick Start Guide This quick start guide describes how to install and use the Industrial Serial Device Server. Capable of operating at temperature extremes of -10 C to +60 C, this is the Serial Device

More information

Quick Start Guide. GV-Video Server

Quick Start Guide. GV-Video Server Quick Start Guide GV-Video Server Thank you for purchasing GV-Video Server. This guide is designed to assist the new user in getting immediate results from the GV-Video Server. For advanced information

More information

C5S120 Installation and Connection Guide

C5S120 Installation and Connection Guide C5S120 Installation and Connection Guide Version: V1.1 1. Cautions Please note the following cautions. Mis-operation may lead to personal injury or equipment failure: 1) Do not energize the system before

More information

BMS: Installation Manual v2.x - Documentation

BMS: Installation Manual v2.x - Documentation Page 1 of 7 BMS: Installation Manual v2.x From Documentation This section describes how external peripheral devices are connected and additional functions of the BMS are used. I you have not done so already,

More information

X-Log Expert Data Logger

X-Log Expert Data Logger > data loggers X-Log Expert Data Logger Highlights Built-in internet stack with web server Setup and data display by any web browser Data-Push to up to three different FTP sites Internal FTP site for easy

More information

F7_F707_F708 Installation Instruction V1.0 F7_F707_F708. Access Control Terminal. Installation Instructions

F7_F707_F708 Installation Instruction V1.0 F7_F707_F708. Access Control Terminal. Installation Instructions F7_F707_F708 Access Control Terminal Installation Instructions Revised May 2008 About this Guide This guide provides installation instructions only. For information regarding actual operation and configuration

More information

GSM-X. Communication module. Quick installation guide. Full manual is available on Firmware version 1.02 gsm-x_sii_en 08/18

GSM-X. Communication module. Quick installation guide. Full manual is available on   Firmware version 1.02 gsm-x_sii_en 08/18 GSM-X Communication module Quick installation guide Full manual is available on www.satel.eu Firmware version 1.02 gsm-x_sii_en 08/18 SATEL sp. z o.o. ul. Budowlanych 66 80-298 Gdańsk Poland tel. +48 58

More information

Product description Rev. 3 11/06/14

Product description Rev. 3 11/06/14 EZ863-2G - GNSS Product description Rev. 3 11/06/14 1 Table of Contents 1. Overview... 4 2. General Description... 4 2.1 Dimensions... 4 2.2 Weight... 4 2.2 Installation... 5 2.3 Casing material... 6 2.4

More information

Poseidon 4002 MANUAL

Poseidon 4002 MANUAL Poseidon 4002 MANUAL Poseidon 4002 MANUAL POWER input 12VDC supply (jack or terminals) INPUTS Binary inputs 1 6 (for contacts) OUTPUTS Two 50V rated switchover relay contacts ETHERNET 10 or 100/10 Mbps

More information

INDEX. Network Power Monitor R10 SNMP

INDEX. Network Power Monitor R10 SNMP Innovative Electronics for a Changing World NPM-R10 Remote Network Power Monitor With optional relay board and GSM module INDEX Amended 21 March 2017: Add user defined Password see page 13 Add wire Connection

More information

EnCell Battery Cell Monitor

EnCell Battery Cell Monitor EnCell Battery Cell Monitor Instruction Manual Model RCM15S12 NERC Compliant YO R U H T PA TO Z O R E W O D N M I T E enchargepowersystems.com sales@enchargepowersystems.com (888) 407.5040 Contents 1 Warnings,

More information

DATA LOGGERS GL800 & 1000

DATA LOGGERS GL800 & 1000 DATA LOGGERS GL800 & 1000 I N S T R U C T I O N M A N U A L 2 CONTENTS Page 1.0 INTRODUCTION 5 1.1 General description 5 1.2 Theory of operation 5 1.3 Main components 6 1.4 Multiplexer (Flexi-Mux) 8 1.4.1

More information

M60. Getting connected with your device

M60. Getting connected with your device M60 Getting connected with your device LEGAL INFORMATION Copyright 2016 TOZED CORPORATION. All rights reserved. We reserve the right to amend the technical parameters of the user manual. We will improve

More information

Innovative Electronics for a Changing World. Charge Smart R1 MPPT 12V/24V Auto detect Mains and Solar Battery charger with Remote Network Monitoring

Innovative Electronics for a Changing World. Charge Smart R1 MPPT 12V/24V Auto detect Mains and Solar Battery charger with Remote Network Monitoring Innovative Electronics for a Changing World Charge Smart R1 MPPT 12V/24V Auto detect Mains and Solar Battery charger with Remote Network Monitoring INDEX 1. SYSTEM DESCRIPTION 2. SYSTEM WIRING 3. SYSTEM

More information

Quick Start Guide. GV-Video Server

Quick Start Guide. GV-Video Server Quick Start Guide GV-Video Server Thank you for purchasing GV-Video Server. This guide is designed to assist new users in getting immediate results from the GV-Video Server. For advanced information on

More information

GreenEye Monitor Specifications

GreenEye Monitor Specifications Number of Channels Power Monitoring Section 32 (expansion available in the future) Measurement POWER: True (or Real) Power using high speed volt and current sampling VOLTAGE: True RMS Accuracy Sampling

More information

PCE-IMS 1 User Manual IP Monitoring systems IP Switchable Metered PDU s

PCE-IMS 1 User Manual IP Monitoring systems IP Switchable Metered PDU s PCE-IMS 1 IP Monitoring systems IP Switchable Metered PDU s System installation System setting Accessories Monitoring master unit Extension units Sensors SNMP server List of USB-cameras - 02 - Contents

More information

WRTU Client User Manual. Date: 29 May, 2014 Document Revision: 1.05

WRTU Client User Manual. Date: 29 May, 2014 Document Revision: 1.05 WRTU Client User Manual Date: 29 May, 2014 Document Revision: 1.05 2014 by BiPOM Electronics, Inc. All rights reserved. WRTU Client User Manual. No part of this work may be reproduced in any manner without

More information

Tu Sitio de Automatización!

Tu Sitio de Automatización! 1. Overview a. Introduction Tu Sitio de Automatización! LBSMS Basic-Q421 is integrated with a 16 bit MCU and reliable Siemens MC39i GSM module. b. Application Industrial equipment monitoring Data capturing

More information

IP68. Autarkic Data Loggers - MT-051 / MT-713 / MT-723

IP68. Autarkic Data Loggers - MT-051 / MT-713 / MT-723 Autarkic Data Loggers - MT-051 / MT-713 / MT-723 Use in the most demanding environments These data loggers are designed for use in difficult to reach and widely distributed locations. In places where neither

More information

Cellcop Communicator CP72u-M

Cellcop Communicator CP72u-M Cellcop Communicator CP72u-M Feb 2015 User Manual ABOUT THE CELLCOP COMMUNICATOR SYSTEM The Cellcop GSM communicator system is based on SMS and GPRS technology. It uses standard cellphone technology for

More information

ICRM SER User s Guide

ICRM SER User s Guide ICRM- 915- SER User s Guide Introduction The ICRM- 915- SER is a high performance serial wireless modem designed to provide reliable long- range communications for SCADA systems. It is supplied in a compact

More information

Up to two expansion cards can be added; these cards may either add an additional 4 analogue or 8 digital inputs.

Up to two expansion cards can be added; these cards may either add an additional 4 analogue or 8 digital inputs. SA380TX-L Hardware The basic TX-L unit features: 4 digital inputs 2 analogue inputs 1 RS485 port 24v 2W auxiliary power supply GSM modem. An Ethernet port can be fitted as an option when ordering. Up to

More information

TG Technical specifications

TG Technical specifications TG2-500 Technical specifications TBox TG2-500 Specifications SPECIFICATIONS Standard: 3 wires 4G Modem -4E: Europe -4N: North America Backup battery charger TG2-500: COMMUNICATION PORTS TG2-500-4E: COMMUNICATION

More information

Integriti 8-32 Zone LAN Expander Module Kit INSTALLATION MANUAL

Integriti 8-32 Zone LAN Expander Module Kit INSTALLATION MANUAL Revision 2.1 July. 2014 1 Integriti 8 32 Zone LAN Expander Module Kit P/N: 996005PCB&K For Rev. B PCB. INSTALLATION MANUAL Overview The Integriti 8 Zone Expander Module provides an additional 8 Zone inputs,

More information

SMM Series 3G and GSM Modems. Quick Start Guide. Document Number: Version: 1.2 (20 October, 2015)

SMM Series 3G and GSM Modems. Quick Start Guide. Document Number: Version: 1.2 (20 October, 2015) SMM Series 3G and GSM Modems Quick Start Guide Document Number: 0013-001-000272 () Documentation Control Generation Date: October 20, 2015 Cybertec Pty Limited All rights Reserved. No part of this publication

More information

GS828-H. GPRS Data Logger

GS828-H. GPRS Data Logger GPRS Data Logger GS828-H Multi Channels Data Logging & Wireless Transmission Upload Data via GPRS and SMS on schedule or alarm triggered Programmable data logging and upload interval Support sensors via

More information

The TRSUN is the complete solution for the remote monitoring of photovoltaic plants.

The TRSUN is the complete solution for the remote monitoring of photovoltaic plants. The TRSUN is the complete solution for the remote monitoring of photovoltaic plants. Monitoring of inverters and string combiner boxes (up to 64 devices); Complete configuration of the monitoring system

More information

MXPLC. Compact PLC process station. Summary. Application HVAC control systems, data acquisition, interfacing 3 rd party systems.

MXPLC. Compact PLC process station. Summary. Application HVAC control systems, data acquisition, interfacing 3 rd party systems. MXPLC Compact PLC process station Summary The MXPLC is a programmable process station with integrated I/O module with the I/O mix optimized for larger HVAC control applications. The multi-interface process

More information

MouldFlo Wiring Manual

MouldFlo Wiring Manual MouldFlo Wiring Manual Copyright (C) 2013 Move Innovation ApS http://www.moveinnovation.dk Table of Contents Introduction... 2 MouldFlo I/O (MFIO)... 3 Power Supply Connection... 4 Manifold Connector Ports...

More information

HWg-Tg11 First steps for remote monitoring & logging via GSM/GPRS

HWg-Tg11 First steps for remote monitoring & logging via GSM/GPRS HWg-Tg11 Manual HWg-Tg11 First steps for remote monitoring & logging via GSM/GPRS Device description Power supply connector - RJ12 connector Device status indicators Red, Green, Yellow indicators Antenna

More information

PCS Ferguson 8000 Series Overview Manual. The PCS Ferguson 8000 Series brand is trademarked by PCS Ferguson.

PCS Ferguson 8000 Series Overview Manual. The PCS Ferguson 8000 Series brand is trademarked by PCS Ferguson. The PCS Ferguson 8000 Series brand is trademarked by PCS Ferguson. These documents and materials are copyrighted by PCS Ferguson. 2016 All rights reserved. For information contact: PCS Ferguson 3771 Eureka

More information

UR72 & UR75 Industrial Cellular Router

UR72 & UR75 Industrial Cellular Router UR72 & UR75 Industrial Cellular Router Quick Start Guide 1 Ursalink Technology Co., Ltd. Welcome Thank you for choosing Ursalink UR72/UR75 industrial cellular router. This guide describes how to install

More information

UC-2000 Installation Manual Unicorn Computers Technology Limited

UC-2000 Installation Manual Unicorn Computers Technology Limited UC2000 Installation Manual Copyright 2003. All rights reserved. Table of Contents Specifications 2 Enclosure for the UC2000 Controller 3 Unicorn Access Control System Configuration 4 UC2000 Controller

More information

F3102 / F3107 / F3110 / F3115 / F3210 / F3215 PN: 86085K K

F3102 / F3107 / F3110 / F3115 / F3210 / F3215 PN: 86085K K F3102 / F3107 / F3110 / F3115 / F3210 / F3215 86085K3000020 PN: 86085K3000030 Zavio F3102/F3107/F3110/F3115/F3210/F3215 Quick Installation Guide Please follow the installation steps below to set up F3102

More information

Chapter1. Interface Introduction

Chapter1. Interface Introduction Robustel GoRugged R3000 Quick Guide Chapter1. Interface Introduction 1.1 LED Indicators After inserting the SIM card into the router and power on, the LED indicators status should be as follow when work

More information

OnCell G3100 Series Quick Installation Guide

OnCell G3100 Series Quick Installation Guide OnCell G3100 Series Quick Installation Guide Edition 4.1, August 2016 Technical Support Contact Information www.moxa.com/support Moxa Americas: Toll-free: 1-888-669-2872 Tel: 1-714-528-6777 Fax: 1-714-528-6778

More information

CRAGG RAILCHARGER Instruction Manual for 10DTC-12V 20DTC-12V 30DTC-24V 40DTC-12V 60DTC-12V

CRAGG RAILCHARGER Instruction Manual for 10DTC-12V 20DTC-12V 30DTC-24V 40DTC-12V 60DTC-12V CRAGG RAILCHARGER for 10DTC-12V 20DTC-12V 30DTC-24V 40DTC-12V 60DTC-12V Contents 1 Warnings, Cautions, and Notes... 1 2 Description... 2 3 Features... 2 3.1 STANDARD FEATURES... 2 3.2 CHARGER REGULATION...

More information

Innovative Electronics for a Changing World INDEX

Innovative Electronics for a Changing World INDEX Innovative Electronics for a Changing World INDEX 1. SYSTEM DESCRIPTION 2. BOARD CONNECTIONS terminals and indicators 3. CONNECTION DIAGRAM 4. START UP GUIDE and passwords 5. HOME PAGE 6. STATUS PAGE 7.

More information

M-Logger Copyright 2011 DGSI. All Rights Reserved.

M-Logger Copyright 2011 DGSI. All Rights Reserved. M-Logger 58810199 Copyright 2011 DGSI. All Rights Reserved. This equipment should be installed, maintained, and operated by technically qualified personnel. Any errors or omissions in data, or the interpretation

More information

Cardax FT Controller 3000

Cardax FT Controller 3000 Installation Note Cardax FT Controller 000 CAUTION This equipment contains components that can be damaged by electrostatic discharge. Ensure both you and the equipment are earthed before beginning any

More information

NI2400/NI816/NI4866 DATALOGGER NI2400/NI816/NI /16/24 CHANNEL ETHERNET DATA LOGGER with Embedded Web Server

NI2400/NI816/NI4866 DATALOGGER NI2400/NI816/NI /16/24 CHANNEL ETHERNET DATA LOGGER with Embedded Web Server DATALOGGER NI2400/NI816/NI4866 8/16/24 CHANNEL ETHERNET DATA LOGGER with Embedded Web Server DATASHEET Rev. 08 del 08/10/2018 Redatto da R&D Approvato da MKT GENERAL 1SPECIFICATIONS NI4866 NI816 NI2400

More information

Quick Start Installation Guide

Quick Start Installation Guide apc/l Quick Start Installation Guide Version A2 Document Part Number UM-201 May 2010 OVERVIEW The apc/l is an intelligent access control and alarm monitoring control panel which serves as a basic building

More information

output devices. connected to the controller. data communications link. relay systems. user program. MECH1500Quiz1ReviewVersion2 Name: Class: Date:

output devices. connected to the controller. data communications link. relay systems. user program. MECH1500Quiz1ReviewVersion2 Name: Class: Date: Class: Date: MECH1500Quiz1ReviewVersion2 True/False Indicate whether the statement is true or false. 1. The number and type of I/Os cannot be changed in a fixed PLC. 2. In a PLC system, there is a physical

More information

UR51 Industrial Cellular Router

UR51 Industrial Cellular Router UR51 Industrial Cellular Router Quick Start Guide 1 Ursalink Technology Co., Ltd. Welcome Thank you for choosing Ursalink UR51 industrial cellular router. This guide describes how to install the UR51 and

More information

NET101. RS232 / RS422 / RS485 to Ethernet Converter. User s Manual. Version 1.2

NET101. RS232 / RS422 / RS485 to Ethernet Converter. User s Manual. Version 1.2 NET101 RS232 / RS422 / RS485 to Ethernet Converter User s Manual Version 1.2 Copyright Information Copyright 2004-2005, Mega System Technologies, Inc. All rights reserved. Reproduction without permission

More information

icex-cmtm General specs and Installation guide

icex-cmtm General specs and Installation guide icex-cmtm General specs and Installation guide 1. General view 2. Specifications 2.1. Common specs: Ethernet 1 x 10/100Base/T, RJ45 connector with traffic and link LED Serial Interface 1 x RS232/485 USB

More information

AUTOLOG GSM-PLC STEP BY STEP

AUTOLOG GSM-PLC STEP BY STEP AUTOLOG GSM-PLC STEP BY STEP AutoLog GSM4 Unit with power supply: Open the cover with screwdriver (GSM4 Unit in picture): Open the cover with screwdriver (GSM14 Unit in picture): AutoLog GSM4 Unit with

More information

DKG-210 UNIVERSAL INTERNET GATEWAY UNIT

DKG-210 UNIVERSAL INTERNET GATEWAY UNIT DKG-210 UNIVERSAL INTERNET GATEWAY UNIT AC & DC SUPPLY VERSIONS DESCRIPTION The DKG-210 is designed for internet monitoring and control of industrial devices using different protocols through the RAINBOW

More information

Strain gauge Measuring Amplifier GSV-1A8. Instruction manual GSV-1A8, GSV-1A8USB, GSV-1A16USB

Strain gauge Measuring Amplifier GSV-1A8. Instruction manual GSV-1A8, GSV-1A8USB, GSV-1A16USB Strain gauge Measuring Amplifier GSV-1A8 Instruction manual GSV-1A8, GSV-1A8USB, GSV-1A16USB GSV-1A8USB SubD1 (front side) GSV-1A8USB M12 (front side) GSV-1A16USB (rear side) GSV-1A8USB K6D (front side)

More information

GSM communicator G16 USER MANUAL

GSM communicator G16 USER MANUAL USER MANUAL UAB TRIKDIS Draugystės str. 17, LT-51229 Kaunas LITHUANIA E-mail: info@trikdis.lt Webpage: www.trikdis.lt Contents SAFETY REQUIREMENTS... 2 DESCRIPTION... 3 LIST OF COMPATIBLE CONTROL PANELS...

More information

JetBox 9300/9310 User Manual. Hardware

JetBox 9300/9310 User Manual. Hardware JetBox 9300/9310 User Manual Hardware www.korenix.com 0.0.6 Copyright Notice Copyright 2008 Korenix Technology Co., Ltd. All rights reserved. Reproduction without permission is prohibited. Information

More information

ACTpro 1500 Single Door IP Controller

ACTpro 1500 Single Door IP Controller ACTpro 1500 Single Door IP Controller ACTpro 1520 Single Door IP Controller with 12 V DC 2 amp power supply. Operating & Installation Instructions 18-00085 Issue 2 This manual refers to the ACTpro 1500

More information

MOULDFLO WIRING MANUAL

MOULDFLO WIRING MANUAL MOULDFLO WIRING MANUAL MOULDFLO A/S Copyright 2017 2860 Søborg - Denmark (DK) www.mouldflo.com 1 Contents Introduction... 3 Mouldflo I/O (MFIO)... 4 Power Supply Connection... 5 Manifold Connector Ports...

More information

Wireless Sensor Networks. FireFly 2.2 Datasheet

Wireless Sensor Networks. FireFly 2.2 Datasheet 2.2 Datasheet July 6, 2010 This page intentionally left blank. Contents 1. INTRODUCTION...1 Features...1 Applications...2 2. BLOCK DIAGRAM...3 3. HARDWARE CONNECTIONS...4 Power...5 Header 1 ( UARTS, I2C,

More information

M2500 Engine Controller Configuration Manual

M2500 Engine Controller Configuration Manual M2500 Engine Controller Configuration Manual Revision: 08-04-2011 Page 1 Contents 1 Preface... 4 2 Configuration from front panel... 5 2.1 Engine Controller Configuration... 6 2.1.1 RPM settings... 6 2.1.2

More information

Banner Connected Data Solutions Web Service

Banner Connected Data Solutions Web Service Banner Connected Data Solutions Web Service Instruction Manual Original Instructions 178337 Rev. E 14 September 2018 Banner Engineering Corp. All rights reserved 178337 Contents 1 Banner Web Services...

More information

EZ864 UMTS Terminal Telit Cellular GSM Engine

EZ864 UMTS Terminal Telit Cellular GSM Engine EZ864 UMTS Terminal Telit Cellular GSM Engine Version: 01.01 EZ864 UMTS Terminal_HD_V01.01 06.Mar.2008-1 - Hardware Interface Description 1. Hardware Features of the EZ864 UMTS Terminal Feature Implementation

More information

Installation of the PCMeasure Movement Sensor (30114)

Installation of the PCMeasure Movement Sensor (30114) 1. Hardware: Installation of the PCMeasure Movement Sensor (30114) Connect the sensor to a serial or parallel port of the PC using one of the PCMeasure adaptors, or directly to the PCMeasure Ethernet Box.

More information

Z-GPRS2-SEAL THE SIMPLEST REMOTE MANAGEMENT SYSTEM FOR UNIVERSAL APPLICATIONS GSM/GPRS DATALOGGER WITH BUILT-IN I/O S AND TELECONTROL FUNCTIONS

Z-GPRS2-SEAL THE SIMPLEST REMOTE MANAGEMENT SYSTEM FOR UNIVERSAL APPLICATIONS GSM/GPRS DATALOGGER WITH BUILT-IN I/O S AND TELECONTROL FUNCTIONS e & Designed GSM / GPRS ETHERNET SMTP HTTP MODBUS TCP-IP USB MODBUS RTU THE SIMPLEST REMOTE MANAGEMENT SYSTEM FOR UNIVERSAL APPLICATIONS www.seneca.it taly 100% ad I in GSM/GPRS DATALOGGER WITH BUILT-IN

More information

GPRS ADAPTER INSTALLATION AND USER MANUAL. for module version v2.24 and higher

GPRS ADAPTER INSTALLATION AND USER MANUAL. for module version v2.24 and higher GPRS ADAPTER INSTALLATION AND USER MANUAL for module version v2.24 and higher Table of contents 1 Main function of the Adapter...3 2 System operation...3 2.1 Transmission through GPRS...4 2.1.1 Router

More information

GS828. GPRS Data Logger

GS828. GPRS Data Logger Sirius Corp GPRS Data Logger Multi Channels Data Logging & Wireless Transmission Upload Data via GPRS and SMS on schedule or alarm triggered Programmable data logging and upload interval Support sensors

More information

IG601 Intelligent Gateway Quick Guide

IG601 Intelligent Gateway Quick Guide IG601 Intelligent Gateway Quick Guide www.inhandnetworks.com Version v1.6 July 2017 1 / 26 Contents 1. PRODUCT INFORMATION... 3 1.1 STANDARD ACCESSORIES... 3 1.2 OPTIONAL ACCESSORIES... 3 2. PHYSICAL LAYOUT...

More information

DLA. DMX512 Analyzer. DLA Users Manual SV2_00 B.lwp copyright ELM Video Technology, Inc.

DLA. DMX512 Analyzer. DLA Users Manual SV2_00 B.lwp copyright ELM Video Technology, Inc. DLA DMX512 Analyzer DLA DLA-HH 1 Table Of Contents IMPORTANT SAFEGUARDS... 2 DLA OVERVIEW... 3 CONNECTION... 3 OPERATION... 3 HARDWARE SETUP... 4 DLA-HH (PORTABLE) LAYOUT... 4 CHASSIS LAYOUT... 4 DLA MENU

More information

User manual Compact Web PLC WP240 series IEC-line. update:

User manual Compact Web PLC WP240 series IEC-line. update: User manual Compact Web PLC WP240 series IEC-line update: 16-06-2017 IEC-line by OVERDIGIT overdigit.com 1. General description The WP240 device is a PLC, programmable in IEC61131-3 language using CoDeSys

More information

WebDAQ 316. Internet Enabled Thermocouple Logger. Remote Configuration and Monitoring. Virtually Unlimited Storage. Integrated HW and SW

WebDAQ 316. Internet Enabled Thermocouple Logger. Remote Configuration and Monitoring. Virtually Unlimited Storage. Integrated HW and SW WebDAQ 316 Internet Enabled Thermocouple Logger Remote Configuration and Monitoring Virtually Unlimited Storage Integrated HW and SW Flexible Triggers, Alarms, Emails, and SMS Texts Built-in Web Server,

More information