HRM-0800 Instruction Manual

Size: px
Start display at page:

Download "HRM-0800 Instruction Manual"

Transcription

1 HRM-0800 Instruction Manual

2 Table of Contents 1 Highway Addressable Remote Transducer (HART ) 4 2 General Specifications 5 3 Dimensions: 6 4 General Description Introduction Purpose Functions 8 5 HRM0800 Presentation 9 6 Features Two Ethernet-Switch Ports mA Pass-Through Built-in Filters and Resistor Terminations DC to DC Converter 10 7 RS-485 Pass Through Operation Connections Details 11 8 Hardware DIP-switches S1, S2 and S HE10 Connection HE10 Pin-Out Connections for Field Devices Passive Transmitter with Analog Input Module Connections Active Transmitter (example for a 24VDC supply Transmitter) Smart valve Without Analog I/O card 15 9 Operation Power ON Behavior LED Indications Holding registers (% MW) Memory map MODBUS Holding Registers ( to ) MODBUS Holding Registers (460011) Web Server Ethernet Setup Static IP Address Embedded Web Pages Home Page Monitoring Device Information Run Time Parameters Diagnostic Page Ethernet Statistics HRM0800 Statistics HRM0800 Setup Configure IP Comm. Settings HRM0800 Configuration 31 Appendix A: Installation recommendations Ethernet architecture Grounding topology according to north America principles 35 REVISION HISTORY 36

3

4 1 Highway Addressable Remote Transducer (HART ) The HART protocol makes use of the Bell 202 FSK standard to superimpose digital signals at a low level on top of the 4-20mA signal. This enables two-way communication and makes it possible for additional information beyond just the normal process variable to be communicated to/from a smart field instrument. The HART protocol communicates without interrupting the 4-20mA signal and allows a host application (master) to get two or more digital updates per second from a field device. As the digital FSK signal is phase continuous, there is no interference with the 4-20mA signal. 4

5 2 General Specifications Part number: Supply for HRM0800 Auxiliary input 24 VDC Supply for individual DC/DC converters Built-in 24 DC/DC converter Communication Ports: HRM V DC 500 ma Auxiliary Input Power Supply connections provided for powering field devices via 8 individual 24V DC-DC 500mA Maximum 1 24 V DC per Channel Continuous Short-Circuit Protection 1. Two RJ45 ports Embedded switch. Usage: - Embedded Web Page for Diagnostics, Ethernet setup - Modbus TCP/IP Data Access 2. One Removable 5-pin Terminal Block RS485, HART pass-through. Usage: - 16 devices maximum without repeater. Field Wire Requirements mm2 (24 16 AWG). Isolation Minimum 1 KV isolation between power supply and communication ports Indication 1. LED1: for HART Pass-Through communication status LED (Yellow) 2. LED2: for HART communication status LED (Yellow ) 3. LED3: Ethernet communication status LED (Yellow ) 4. LED4: Module OK/Scanning Status LED (Green ) 5. CH1-8 Over Current Fault Indication (30 ma) (Red ) Isolation HART channels are transformer isolated. (1.5KV between HART modem and HART field device) Polarity independent connection on the HART side. 30V DC isolation Channel to Channel. No. of HART Device per Channel 1 device per channel. HART Protocol Revision 7 supported. Secondary master device is supported. (i.e.: handheld configuration tool) Module Configuration Configuration via Ethernet port using embedded Web Pages (HTTP) DIP switches SW1 ON Position: 250 ohm termination disabled DIP switches SW2 ON Position: Filtering enabled DIP switches SW3 ON Position: without analog I/O Dimensions 155mm X 102 mm X 48mm Operating Temperature 0 to 60ºC Storage Temperature -20 C to +80 C, non-operating Operating Humidity 10-90%, non-condensing Compliance CE, UL, RoHS 5

6 3 Dimensions: Side View Top View 6

7 Instruction Manual: HRM Pub.: 01/2013 Rev General Description 4.1 Introduction This manual provides guidance for the installation, operation and maintenance of the product HRM0800 (8 channels HART Interface Multiplexer). Typical block diagram: HE10 connector ModbusTCP Embedded Ch1(+) Ch1(-)...Ch4(+)Ch4(-) Ch5(+)Ch5(-)... Ch8(+)Ch8(-) Servers HTTP HART Pass-Through HART Modem Embedded Switch CPU Addressable RS-485 HART Pass-through HART Modem... (1) Asset Management or HART OPC client connection via Serial RS485 Port or Ethernet. (2) Module Configuration via web pages and Asset Management via Modbus/ TCP-IP. Note: Asset Management Available on either the Ethernet OR RS-485 port at one time. 7

8 4.2 Purpose The HRM0800 is a HART Interface Multiplexer unit, which allows access to 8 Channels HART communications on existing 4-20mA loop. 4.3 Functions At power up the module scans the 8 channels and retrieves all the HART Data (Manufacture ID, Device ID, etc.). This information is routed to three internal memory areas: Pass-Through PC can use this port for configuration of field instruments Embedded Web Server (HTML pages) Most HART Data can be viewed on web pages using standard web clients (Internet Explorer 7.0, Fire Fox, Netscape, etc.) x Registers Mapping (Holding Registers) All HART data from each detected device can be mapped to holding registers (4X). The default configuration uses 14 holding registers per channel and can be modified to meet your applications using the configuration web page. The information can be accessed using standard Modbus / TCP- IP protocol. 8

9 Instruction Manual: HRM Pub.: 01/2013 Rev HRM0800 Presentation HRM0800 is a HART Interface Multiplexer. It contains 8 channels and two HART modem. 1 8 Channel Connectors 7 24 Vdc Supply for HRM S2 Switch/Ch for Built-In Filter 8 HE10 Connector for 4-20 ma, 8 Channels 3 S1 Switch/Ch for 250 Ohms toward PLC 4 S3 Switch/Ch without analog I/O 9 RS485 HART Pass-Through port 5 Auxiliary input 24 Vdc Supply for 10 RJ45 Shielded Ethernet built-in two port Switch individual DC/DC converters 6 Current Limit Indications per CH

10 6 Features 6.1 Two Ethernet-Switch Ports The HRM0800 is equipped with two Shielded Ethernet Switch ports, used to daisy chain multiple modules mA Pass-Through The 4-20mA signals for each channel are accessible via the HE10 connector. Various quick connect cables are available for easy connection to PLC analog input/output modules. 6.3 Built-in Filters and Resistor Terminations The HRM0800 has three sets of 8 dip switches. Each channel has one dip switch assigned from each of the sets. The first switch is used to provide internal 250 Ohms resistor loop impedance when the PLC analog input does not provide it. The second switch is used to enable the filtering of the HART information when a smart valve is used. The third switch is to close the current loop when the module is used without an analog I/O card. 6.4 DC to DC Converter The HRM0800 has two 24 VDC power inputs; both can be supplied with one source. The first 24Vdc input is used to supply HRM0800 and the second 24Vdc supply input is re-distributed to supply the loop current for each channel. The supply of each channel is isolated using a DC to DC converter. The DC to DC converter can deliver 1 Watts to the connected load. 10

11 7 RS-485 Pass Through Operation 7.1 Connections Details The Pass-Through port is the RS 485 port. It can be configured as 2 wire or 4 wire depending on the need. Connection details for the port: RX+ RX- GND TX- TX+ RX+ RX- GND TX- TX+ 11

12 8 Hardware To connect field devices, 3.81mm pitch 8X6 pole double deck connector is used; six poles per channel are needed. For the control system analog input or output module, the Quick Connect HE10 connectors are used (please refer to Appendix A for a list of available cables and pin-out diagrams). 8.1 DIP-switches S1, S2 and S3 Switch S1 : used to bypass the 250 Ohm line impedance of the module. Switch S2 : used to connect the filtering capacitor. Switch S3 : use the module without analog IO card. Operating modes (Analog passthrough side) Switch Settings S1 S2 S3 a. Without Analog I/O module OFF OFF ON b. With Analog Input module with filter OFF ON OFF c. With Analog Input module without filter ON OFF OFF d. With Analog Output module OFF OFF OFF With the above configuration we can do following configuration: a. Without Analog I/O module: Current loop is completed manually through switch or from HE10 connector. b. With Analog Input module with filter: Loop is complete by connecting Input module in series i.e. across analog passthrough. c. With Analog Input module without filter: Loop is complete by connecting Input module in series i.e. across analog passthrough. d. With Analog Output mode : Loop is complete by connecting Output module in series i.e. across analog passthrough. 8.2 HE10 Connection The HE10 connection is used to connect the analog input or output module of the control system. A series of Quick-Connect cables are available for the following analog IO cards: ACO ACI ACI/AVI ACO I/O High Density Analog Out I/O Module (8 Ch) High Density Analog In I/O Module (16 Ch) I/O Analog In Module (8 Ch Differential) Analog Out Module (4 Ch) 12

13 8.2.1HE10 Pin-Out CH-1 HART +ve CH-1 HART -ve CH-2 HART +ve CH-2 HART -ve CH-3 HART +ve CH-3 HART -ve CH-4 HART +ve CH-4 HART -ve CH-5 HART +ve CH-5 HART -ve CH-6 HART +ve CH-6 HART -ve CH-7 HART +ve CH-7 HART -ve CH-8 HART +ve CH-8 HART -ve N/C N/C N/C N/C 13

14 8.3 Connections for Field Devices 8.3.1Passive Transmitter with Analog Input Module Connections 8.3.2Active Transmitter (example for a 24VDC supply Transmitter) 8.3.3Smart valve 14

15 8.3.4 Without Analog I/O card Caution: Ch-x +24V [4] and Ch-x GND [5] are the outputs of the internal Dc to Dc converter. Note: Do not connect outside power to it. Please refer to wiring diagram to connect external supply. 15

16 9 Operation 9.1 Power ON Behavior OK LED Flashing slow : HRM0800 Update connection window (up to 10 Sec). OK LED Flashing rapid : HRM0800 Internal test (up to 10 Sec). Ethernet OK LED steady on: Ethernet enabled. HART OK LED flashing: HRM0800 scanning for field devices (up to 20 sec). HART OK LED steady: At least one device found and connected. 9.2 LED Indications 8 x LED Current Limitations (RED): Over current indication >= 30 ma. OK LED (Green): HRM0800 health. Ethernet OK (Yellow): Ethernet configuration. HART OK: Field device (transmitter/smart valve) connection status. Pass-Through (Yellow): RS-485 Pass-through activity. HRM0800 LED indications: Name Color Status Description Over Current LED ON Over Current : Loop Current >= 30 ma (one per Channel) OFF Normal Operation: Loop Current < 30mA OK LED Flashing slow In Upgrade mode : used for Firmware upgrade Flashing rapid Internal test ON Normal Operation OFF HRM0800 Power Supply not connected Hardware failure: Call your regional office Ethernet OK ON Ethernet Port ON HART OK Flashing Scanning for HART Field Device ON At least One Device Connected OFF No Devices detected Pass-Through ON Flashing RS-485 pass through connected and data transmitting is active. OFF No Connection 16

17 10 Holding registers (% MW) Memory map HRM0800 supports Modbus function code 03 (Read Holding Registers), 16 (Write Holding registers) and 23 (read/write Holding registers). When using the IO Scanning function to read the HRM holding register, the Unit ID has to be set to 1. Default memory map between HART values and Modbus registers (4X, % MW). Holding Register IEC Map Description Data type Bytes %MW3 CH-0 Current Value Float %MW5 CH-0 Percentage Value Float %MW7 CH-0 Device Status Word %MW9 CH-0 Primary Variable Float %MW11 CH-0 Secondary Variable Float %MW13 CH-0 Tertiary Variable Float %MW15 CH-0 Quaternary Variable Float %MW17 CH-1 Current Value Float %MW19 CH-1 Percentage Value Float %MW21 CH-1 Status Word %MW23 CH-1 Primary Variable Float %MW25 CH-1 Secondary Variable Float %MW27 CH-1 Tertiary Variable Float %MW29 CH-1 Quaternary Variable Float %MW31 CH-2 Current Value Float %MW33 CH-2 Percentage Value Float %MW35 CH-2 Status Word %MW37 CH-2 Primary Variable Float %MW39 CH-2 Secondary Variable Float %MW41 CH-2 Tertiary Variable Float %MW43 CH-2 Quaternary Variable Float %MW45 CH-3 Current Value Float %MW47 CH-3 Percentage Value Float %MW49 CH-3 Status Word %MW51 CH-3 Primary Variable Float %MW53 CH-3 Secondary Variable Float %MW55 CH-3 Tertiary Variable Float %MW57 CH-3 Quaternary Variable Float %MW59 CH-4 Current Value Float %MW61 CH-4 Percentage Value Float %MW63 CH-4 Status Word %MW65 CH-4 Primary Variable Float %MW67 CH-4 Secondary Variable Float %MW69 CH-4 Tertiary Variable Float %MW71 CH-4 Quaternary Variable Float %MW73 CH-5 Current Value Float %MW75 CH-5 Percentage Value Float %MW77 CH-5 Status Word %MW79 CH-5 Primary Variable Float %MW81 CH-5 Secondary Variable Float %MW83 CH-5 Tertiary Variable Float %MW85 CH-5 Quaternary Variable Float 4 17

18 Holding Register IEC Map Description Data type Bytes %MW87 CH-6 Current Value Float %MW89 CH-6 Percentage Value Float %MW91 CH-6 Status Word %MW93 CH-6 Primary Variable Float %MW95 CH-6 Secondary Variable Float %MW97 CH-6 Tertiary Variable Float %MW99 CH-6 Quaternary Variable Float %MW101 CH-7 Current Value Float %MW103 CH-7 Percentage Value Float %MW105 CH-7 Status Word %MW107 CH-7 Primary Variable Float %MW109 CH-7 Secondary Variable Float %MW111 CH-7 Tertiary Variable Float %MW113 CH-7 Quaternary Variable Float 4 Status Registers Holding Register IEC Map Description Data type Bytes %MW59999 CH-0 connection status Word 2 MSB, channel connected 15 s LSB exchange count %MW60000 CH-1 connection status Word 2 MSB, channel connected 15 s LSB exchange count %MW60001 CH-2 connection status Word 2 MSB, channel connected 15 s LSB exchange count %MW60002 CH-3 connection status Word 2 MSB, channel connected 15 s LSB exchange count %MW60003 CH-4 connection status Word 2 MSB, channel connected 15 s LSB exchange count %MW60004 CH-5 connection status Word 2 MSB, channel connected 15 s LSB exchange count %MW60005 CH-6 connection status Word 2 MSB, channel connected 15 s LSB exchange count %MW60006 CH-7 connection status Word 2 MSB, channel connected 15 s LSB exchange count %MW60007 HRM health status : Word 2 If LSB is 1 then OK Otherwise fail %MW60008 HRM RS-485 Port status Word 4 If LSB is 1 then OK Otherwise fail %MW60010 HRM rescan mode Word 2 8th LSB mode 7 s LSB manual mode mask 18

19 10.1 MODBUS Holding Registers ( to ) Representation of one HART Channel Refresh count Status register of HRM: 10.2 MODBUS Holding Registers (460011) MODBUS holding register keeps the status of Rescan of HRM. This register contains two different fields. The detail of this register is showing below: First field: 8th bit of register, is showing the rescan mode whether it is auto or manual. If this bit is non-zero then auto rescan is selected and if zero then manual rescan is selected. Second field: Lower 8 bits of register, is showing the status that, which channel request are sending manually. The second field has no meaning if the rescan mode is auto. This 8 bits corresponds to 8 HART channels of HRM and if any users wants to connect channel manually then they make a zero to one transition on that particular bit which corresponds to requested channel i.e. same as what we are doing on Web Server for Rescan. Representation of Rescan Status register of HRM: 19

20 11 Web Server 11.1 Ethernet Setup Static IP Address Ethernet default setting IP Address: SubnetMask: Gateway: Connect a cross-over OR a straight-through cable (automatic detected). Change the PC Ethernet settings to match the xxx network. Example: Control Panel > Network Settings > TCP/IP Properties Change to. 20

21 Open an Internet Browser and type the IP address of the unit HRM0800 as (Internet Explorer 7 is used in this example). The HRM0800 s home page should be loaded. Click on the Setup tab and the Login window will pop up, User Name: USER and Password : USER. Then Setup menu appears and you can select the device IP configuration. 21

22 Click on the Configure IP, and change to the desired IP address. Click Update Configuration and a message will pop up to Confirm Changes. 22

23 Click OK and a confirmation page will appear. The HRM0800 will automatically reboot with the new address. Please take note of your new IP address. 23

24 11.2 Embedded Web Pages Home Page Monitoring 24

25 Device Information Different Channel Status: 25

26 Run Time Parameters For Different Channel: % (mA) (mA) % 42D1 26

27 Diagnostic Page Ethernet Statistics 27

28 HRM0800 Statistics N.C- -N.C- -N.C- -C- -N.C- -N.C- -N.C- -N.C Q 131.3P 003.3H HRM0800 Setup 28

29 Configure IP 00:17:F1:00:03:0C 29

30 Comm. Settings Communication Settings: RS-485 Baud rate Select the baud rate for the RS-485 port for operation. Available rate : 9600, and baud. HRM0800 ID Enter the HRM0800 address for the RS-485 communication, that value is also used as a unique identifier for Ethernet HART pass through. Rescan Mode Auto: the HRM0800 rescan all free channels every 30 seconds to detect newly connected device. Manual: the HRM0800 will rescan only the channel selection for the newly connected device. Channel setting The channel value in HEX format you want to rescan when in manual. Example: to scan channel 5 and 7, the value to enter is 0A HEX. 30

31 HRM0800 Configuration These pages enable the user to convert Modbus register value to HART command messages. By selecting the source and the HART command, Modbus Registers values are converted to HART transaction. 31

32 Once configured the Modbus/TCP host is able to read and write to these registers and establish communication to retrieve or write critical HART data to and from the field device. HRM0800 Module Configuration Source Select HART for a read command or Modbus TCP for a write command. HART Configuration Channel (0 to 7) Enter the channel you want to communicate with. Command length Enter the length of the HART command (16 bits register). Type UC: Universal command. CP: Common practice command. DR: Device specific read command. DW: Device specific write command. RC: Read Command. Note: For the complete Command definitions, please refer to HART commands are divided in 3 types, the Universal Command, the Common Practice and the Device Specific Command. For HRM0800, Device Specific Commands were divided in two groups, the DR for the read and the DW for the Write. To facilitate the Modbus register mapping for Universal command 2 and 3, RC 2 and RC 3 commands were created. These commands have been formatted to fit Modbus register. RC 2 response: Registers 0-1: Current (ma) floating point formatted Registers 2-3: Percentage of range floating point formatted Registers 4-5: Device status RC 3 response: Registers 0-1: Primary variable floating point formatted Registers 2-3: Secondary variable floating point formatted Registers 4-5: Third variable floating point formatted Registers 6-7: Fourth variable floating point formatted [xxx-xxx] Enter the HART command number, - UC range from 0 to CP range from 32 to DX range from 128 to 999 NOTE: Please refer to instrument manual for the complete list of supported HART commands. Modbus Configuration Type Select register and type the command or respond for that HART command. 32

33 Address Enter the start address for the command or response of the HART command. Example: To add a new line to use Universal command #15 to read the output information of the device connected to channel #0 and store the information in to registers and following. The Source: read command so the source will be HART. The Channel: 0. The Length: the command response is 17 bytes long so 9 registers are needed. The Type: UC for Universal Command. The Command number: 15. The Modbus type: 4 for 4x registers. The Address: start at

34 Appendix A: Installation recommendations 12.1 Ethernet architecture 1) a higher level Ethernet network connects the gateway local switches together. 2) The gateways may be connected to the local switch in open loop daisy chain or star topology. 34

35 12.2 Grounding topology according to north America principles rules : 1) Each cabinet or junction box must be connected to the local ground. 2) The body of the device must be connected to the local ground. 3) The shield of the cable connected to the gateway cabinet must be connected to the cabinet. 4) In order to prevent from current flow in the cable shields due to local grounds voltage differences, only one point of each shielded cable must be grounded For a good EMC characteristics, the shield of the cables should be connected to the cabinet using a 360 s shieldbonding cable component, on the other end of the cable, the shield should be cut close to the cable isolation end and isolated using for example a thermal shrinkable isolator. DANGER : before working on the unconnected shield end of a cable (for example when isolating the shield), it is mandatory to isolate the other end of the cable shield from the ground, in order to prevent from a possible electric shock. Failing to this can lead to human injury or death. 35

36 REVISION HISTORY /i A manual revision code appears to the bottom of this manual and on the front cover of the manual. Doc. No.: UMAN/HRM0800 Ver.: 1.00 /i The following table outlines the changes made to the manual during each revision. The page numbers of a revision refer to the previous version. Revision code Date Revised content First Draft

PRM Integration Guide with Pepperl+Fuchs HiDMUX2700 HART Multiplexer

PRM Integration Guide with Pepperl+Fuchs HiDMUX2700 HART Multiplexer PRM Integration Guide with Pepperl+Fuchs HiDMUX2700 HART Multiplexer This manual explains how to connect the HiDMUX2700 HART Multiplexer and configure Yokogawa s Plant Resource Manager (PRM) software.

More information

4.6 PT8AIIS ISOLATED ANALOG CURRENT INPUTS Description

4.6 PT8AIIS ISOLATED ANALOG CURRENT INPUTS Description 4.6 PT8AIIS ISOLATED ANALOG CURRENT INPUTS 4.6.1 Description The PT8AIIS module is an 8 channel isolated current input module. The module uses differential inputs to reduce effects of electrical noise

More information

Intech Micro 2300-A8VI analogue input station MODBUS RTU slave application supplementary manual.

Intech Micro 2300-A8VI analogue input station MODBUS RTU slave application supplementary manual. Intech Micro 2300-A8VI analogue input station MODBUS RTU slave application supplementary manual. MODBUS supplementary manual to the 2300-A8VI Installation Guide. The 2300 series stations are designed to

More information

Intech Micro 2300-RTD6 analogue input station MODBUS RTU slave application supplementary manual.

Intech Micro 2300-RTD6 analogue input station MODBUS RTU slave application supplementary manual. Intech Micro 2300-RTD6 analogue input station MODBUS RTU slave application supplementary manual. MODBUS supplementary manual to the 2300-RTD6 Installation Guide. The 2300 series stations are designed to

More information

ECAN-240. (Modbus TCP to 2-port CAN Bus Gateway User manual) ECAN-240 Modbus TCP to 2-port CAN Bus Gateway User Manual, Version 1.0.

ECAN-240. (Modbus TCP to 2-port CAN Bus Gateway User manual) ECAN-240 Modbus TCP to 2-port CAN Bus Gateway User Manual, Version 1.0. ECAN-240 (Modbus TCP to 2-port CAN Bus Gateway User manual) ECAN-240 Modbus TCP to 2-port CAN Bus Gateway User Manual, Version 1.0.0 Page: 1 Table of Contents Table of Contents -----------------------------------------------------------------------------2

More information

HART / EtherNet/IP Gateway GT200-HT-EI User Manual V 1.0 REV A SST Automation

HART / EtherNet/IP Gateway GT200-HT-EI User Manual V 1.0 REV A SST Automation HART / EtherNet/IP Gateway GT200-HT-EI V 1.0 REV A SST Automation E-mail: SUPPORT@SSTCOMM.COM WWW.SSTCOMM.COM Catalog 1 Product Overview... 4 1.1 Product Function...4 1.2 Product Features... 4 1.3 Technical

More information

MODEL CIO-EN MODBUS/TCP, MODBUS/RTU I/O MODULE

MODEL CIO-EN MODBUS/TCP, MODBUS/RTU I/O MODULE INSTALLATION INSTRUCTIONS Revision B1 Rapid City, SD, USA, 05/2009 MODEL CIO-EN MODBUS/TCP, MODBUS/RTU I/O MODULE BE SURE POWER IS DISCONNECTED PRIOR TO INSTALLATION! FOLLOW NATIONAL, STATE AND LOCAL CODES.

More information

General Specifications. P2-SCM Serial Communications

General Specifications. P2-SCM Serial Communications General Specifications Module Type Intelligent Modules per Base I/O Points Used Field Wiring Connector Operating Temperature Storage Temperature Humidity Environmental Air Vibration Shock Field to Logic

More information

HART/ Modbus TCP Gateway GT200-HT-MT User Manual V 1.2 REV A SST Automation

HART/ Modbus TCP Gateway GT200-HT-MT User Manual V 1.2 REV A SST Automation HART/ Modbus TCP Gateway GT200-HT-MT User Manual V 1.2 REV A SST Automation E-mail: SUPPORT@SSTCOMM.COM WWW.SSTCOMM.COM Catalog 1 Product Overview... 4 1.1 Product Function...4 1.2 Product Features...

More information

Motortronics VirtualSCADA VS2-MT Communication Gateway VS2-MT User Manual Revision

Motortronics VirtualSCADA VS2-MT Communication Gateway VS2-MT User Manual Revision Motortronics VirtualSCADA VS2-MT Communication Gateway VS2-MT User Manual Revision 1.03.00 Motortronics / Phasetronics 1600 Sunshine Drive Clearwater, Florida 33765 Tel: 727-573-1819 Fax: 727-573-1803

More information

MPI-DN, MPI-D MULTICHANNEL ELECTRONIC RECORDER for HART or RS-485/ MODBUS RTU SENSORS

MPI-DN, MPI-D MULTICHANNEL ELECTRONIC RECORDER for HART or RS-485/ MODBUS RTU SENSORS MPI-DN, MPI-D MULTICHANNEL ELECTRONIC RECORDER for HART or RS-485/ MODBUS RTU SENSORS 18 channels for HART / Modbus RTU sensors 2 digital channels 16 math channels 4 relay outputs for alarm or control

More information

Intech Micro 2300-RO4 analogue input station MODBUS RTU slave application supplementary manual.

Intech Micro 2300-RO4 analogue input station MODBUS RTU slave application supplementary manual. Intech Micro 2300-RO4 analogue input station MODBUS RTU slave application supplementary manual. MODBUS supplementary manual to the 2300-RO4 Installation Guide. The 2300 series stations are designed to

More information

Serial to Ethernet Converter

Serial to Ethernet Converter Serial to Ethernet Converter User s Manual Version 1.1 2004 Infosystem Technology Corporation Disclaimers The information in this manual has been carefully checked and is believed to be accurate. Infosystem

More information

CDN502 HIGH DENSITY I/O ADAPTER USER GUIDE

CDN502 HIGH DENSITY I/O ADAPTER USER GUIDE CDN502 HIGH DENSITY I/O ADAPTER USER GUIDE 13050201 (c) Copyright DIP Inc., 1996 DIP Inc. P.O. Box 9550 MORENO VALLEY, CA 92303 714-924-1730 CONTENTS DN502 PRODUCT OVERVIEW 1 DN502 INSTALLATION 1 POWER

More information

QUICK SETUP GUIDE PMC-1000, PMC-1001, PMM-1000, PMB PM Series Power Meter. Safety Information. Equipment Maintenance and Service.

QUICK SETUP GUIDE PMC-1000, PMC-1001, PMM-1000, PMB PM Series Power Meter. Safety Information. Equipment Maintenance and Service. PM Series Power Meter QUICK SETUP GUIDE PMC-1000, PMC-1001, PMM-1000, PMB-1960 Safety Information DANGER! HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH Follow safe electrical work practices. See NFPA

More information

Features. :. Introduction. :. Leader 5000 Appearance. Ethernet-Based Block I/O System

Features. :. Introduction. :. Leader 5000 Appearance. Ethernet-Based Block I/O System Features 10/100Mbps Ethernet full duplex Auto Negotiation Support C++/C Modbus/TCP drivers and OPC server Support configuration via built-in Web browsing, (HTML), Device Finder and I/O configuration utilities

More information

BL compact multiprotocol fieldbus station for Industrial Ethernet 8 Analog Inputs for Current or Voltage BLCEN-8M12LT-4AI-VI-4AI-VI

BL compact multiprotocol fieldbus station for Industrial Ethernet 8 Analog Inputs for Current or Voltage BLCEN-8M12LT-4AI-VI-4AI-VI On-machine Compact fieldbus I/O block EtherNet/IP, Modbus TCP, or PROFINET slave Integrated Ethernet Switch 10 Mbps / 100 Mbps Two 4-pole M12, D-coded, connectors for fieldbus connection 2 rotary switches

More information

I-7570 Serial To HART Converter

I-7570 Serial To HART Converter I-7570 Serial To HART Converter User s Manual Warranty All products manufactured by ICP DAS are under warranty regarding defective materials for a period of one year from the date of delivery to the original

More information

Catalog 1 Product Overview General Important User Information About the Gateway Function Features Tec

Catalog 1 Product Overview General Important User Information About the Gateway Function Features Tec PROFIBUS DP / Modbus TCP Gateway EP-321MP User Manual REV 1.2 Sibotech Automation Co., Ltd Technical Support: 021-5102 8348 E-mail:support@sibotech.net Catalog 1 Product Overview... 4 1.1 General...4 1.2

More information

Du line. Dupline Field- and Installationbus Dupline Ethernet Modbus/TCP Gateway Type G G Type Selection

Du line. Dupline Field- and Installationbus Dupline Ethernet Modbus/TCP Gateway Type G G Type Selection Dupline Field- and Installationbus Dupline Ethernet Modbus/TCP Gateway Type G 3891 0052 Built-in Dupline channel generator Modbus/TCP Slave 10 and 100 Mbit operation, full or half duplex Twisted pair cables

More information

IntesisBox Modbus Server Panasonic

IntesisBox Modbus Server Panasonic IntesisBox Modbus Server - Panasonic Gateway for Panasonic ECO-i VRF and PAC-i system integration into Modbus Systems Master Up to 30 Outdoor units Up to 64 Indoor units Modbus TCP Master /EIA232 PA-AC-MBS-64/128

More information

Description of options. user s manual. DEIF A/S Frisenborgvej 33 DK-7800 Skive Tel.: Fax:

Description of options. user s manual. DEIF A/S Frisenborgvej 33 DK-7800 Skive Tel.: Fax: Description of options TCP/IP Ethernet module user s manual DEIF A/S Frisenborgvej 33 DK-7800 Skive Tel.: +45 9614 9614 Fax: +45 9614 9615 info@deif.com www.deif.com Document no.: 4189320029B Legal information

More information

HES. Description. Industrial Internet of Things - HART Over Ethernet

HES. Description. Industrial Internet of Things - HART Over Ethernet September 2018 Description The HART to Gateway System converts signals from wired HART devices to and HART-IP. The offers a flexible and economical way to gather process data and instrument diagnostics

More information

PROLOGIC Modular PLC CPU & I/O Modules Catalog and Design Guide

PROLOGIC Modular PLC CPU & I/O Modules Catalog and Design Guide PROLOGIC Modular PLC CPU & I/O Modules Catalog and Design Guide 23/03/2007 V0.1 Preliminary P.O.Box 24 Stanfield 3613 SOUTH AFRICA Tel: +27 (031) 7028033 Fax: +27 (031) 7028041 Email: proconel@proconel.com

More information

Do-more H2 Series PLC System Specifications

Do-more H2 Series PLC System Specifications Do-more H2 Series PLC System Specifications General Specifications General Specifications Operating Temperature 32 F to 131 F (0 C to 55 C) Storage Temperature 4 F to 158 F ( 20 C to 70 C) Ambient Humidity

More information

BL compact multiprotocol fieldbus station for Industrial Ethernet 8 Analog Inputs for Thermocouple Elements BLCEN-8M12LT-4AI-TC-4AI-TC

BL compact multiprotocol fieldbus station for Industrial Ethernet 8 Analog Inputs for Thermocouple Elements BLCEN-8M12LT-4AI-TC-4AI-TC On-machine Compact fieldbus I/O block EtherNet/IP, Modbus TCP, or PROFINET slave Integrated Ethernet Switch 10 Mbps / 100 Mbps Two 4-pole M12, D-coded, connectors for fieldbus connection 2 rotary switches

More information

NCOM SERIAL DEVICE SERVER 4XX SERIES USER S MANUAL

NCOM SERIAL DEVICE SERVER 4XX SERIES USER S MANUAL NCOM SERIAL DEVICE SERVER 4XX SERIES USER S MANUAL 2017-07-07 Edition Titan Electronics Inc. Web: www.titan.tw Contents 1. INTRODUCTION... 4 1.1 Key Features... 5 1.2 Specifications... 6 2. PANEL LAYOUT

More information

Type code. BLCEN-8M12LT-4AI-VI-8XSG-P Ident-No Nominal system voltage 24 VDC. Nominal current Vo Max. current Vo

Type code. BLCEN-8M12LT-4AI-VI-8XSG-P Ident-No Nominal system voltage 24 VDC. Nominal current Vo Max. current Vo On-machine Compact fieldbus I/O block EtherNet/IP, Modbus TCP, or PROFINET slave Integrated Ethernet Switch 10 Mbps / 100 Mbps Two 4-pole M12, D-coded, connectors for fieldbus connection 2 rotary switches

More information

Multi-instrument Communication, MIC-2 MKII DIN Quick Start Guide

Multi-instrument Communication, MIC-2 MKII DIN Quick Start Guide Multi-instrument Communication, MIC-2 MKII DIN Quick Start Guide Warnings and legal information Installation and terminals Communication I/O options Alarming Utility software More information Specifications

More information

CDN503 HIGH DENSITY I/O ADAPTER USER GUIDE

CDN503 HIGH DENSITY I/O ADAPTER USER GUIDE CDN503 HIGH DENSITY I/O ADAPTER USER GUIDE 13050301 (c) Copyright DIP Inc., 1996 DIP Inc. P.O. Box 9550 MORENO VALLEY, CA 92303 714-924-1730 CONTENTS DN503 PRODUCT OVERVIEW 1 DN503 INSTALLATION 1 POWER

More information

PM Series Power Meter

PM Series Power Meter PM Series Power Meter Quick Setup Guide - PMC-1000, PMC- 1001, PMM-1000, PMB-1960 Safety Information DANGER! HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH Follow safe electrical work practices. See

More information

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

See instructions to download and install the latest version of LinkBoxMB and the user's manual at Safety Instructions WARNING Follow carefully this safety and installation instructions. Improper work may lead to serious harmful for your health and also may damage seriously the IntesisBox and/or any

More information

D-100 FLOW DISPLAY MODBUS Network Interface Installation Guide

D-100 FLOW DISPLAY MODBUS Network Interface Installation Guide MODBUS D-100 FLOW DISPLAY MODBUS Network Interface Installation Guide 11451 Belcher Road South, Largo, FL 33773 USA Tel +1 (727) 447-6140 Fax +1 (727) 442-5699 www.onicon.com sales@onicon.com 03-18 0657-9

More information

iologic E1200 Series Remote Ethernet I/O with 2-port Ethernet Switch Introduction Industrial I/O

iologic E1200 Series Remote Ethernet I/O with 2-port Ethernet Switch Introduction Industrial I/O iologic E1200 Series Remote Ethernet I/O with 2-port Ethernet Switch Build-in 2-port Ethernet switch for daisy-chained topology Free push-based Moxa Active OPC Server Lite support Seamlessly connect to

More information

P3-SCM. General Specifications

P3-SCM. General Specifications General Specifications Module Type Modules per Base Modules per Group I/O Points Used Field Wiring Connector Operating Temperature Storage Temperature Humidity Environmental Air Vibration Shock Field to

More information

Soft Starter Remote Operator. Section 1.0 Introduction 1.1 Important user information General Manual description...2.

Soft Starter Remote Operator. Section 1.0 Introduction 1.1 Important user information General Manual description...2. Section 1.0 Introduction 1.1 Important user information... 2 1.2 General... 2 1.3 Manual description...2 Contents Section 2.0 Specification 2.1 General technical data...3 2.2 Dimensions...3 Section 3.0

More information

Multi-instrument Communication, MIC-2 MKII DIN Quick Start Guide

Multi-instrument Communication, MIC-2 MKII DIN Quick Start Guide Multi-instrument Communication, MIC-2 MKII DIN Quick Start Guide Warnings and legal information Installation and terminals Communication I/O options Alarming Utility software More information Specifications

More information

Fieldgate SFG500. Technical Information. Intelligent Ethernet/PROFIBUS gateway

Fieldgate SFG500. Technical Information. Intelligent Ethernet/PROFIBUS gateway Technical Information Fieldgate Intelligent Ethernet/PROFIBUS gateway Application Fieldgate is a system component that provides an independent access route to a PROFIBUS network. It may be used in a variety

More information

iologik E1200H Series

iologik E1200H Series iologik E1200H Series Ethernet remote I/O for offshore wind power applications Features and Benefits User-definable Modbus TCP Slave addressing 2-port Ethernet switch for daisy-chain topologies Active

More information

Support 1 RS-232 or RS-485/422 serial port to 1 10/100Base-T(X) self-adaptive Ethernet interface

Support 1 RS-232 or RS-485/422 serial port to 1 10/100Base-T(X) self-adaptive Ethernet interface GW1101 Series Wall Mounting 1 RS-232 or RS-485/422 Modbus Gateway Support 1 RS-232 or RS-485/422 serial port to 1 10/100Base-T(X) self-adaptive Ethernet interface Support conversion between Modbus RTU/ASCII

More information

24VDC Bipolar Digital In 10-28VDC, 0.5A Sourcing Digital Out 0-20mA Sourcing Analog In/ Out HE800MIX906 / HE-MIX906* * HE- denotes plastic case.

24VDC Bipolar Digital In 10-28VDC, 0.5A Sourcing Digital Out 0-20mA Sourcing Analog In/ Out HE800MIX906 / HE-MIX906* * HE- denotes plastic case. MAN0456-02 20 MAY 2006 PAGE 1 24VDC Bipolar Digital In 10-28VDC, 0.5A Sourcing Digital Out 0-20mA Sourcing Analog In/ Out HE800 / HE-* * HE- denotes plastic case. This datasheet also covers products starting

More information

QUCM Limitorque Controller

QUCM Limitorque Controller QUCM Limitorque Valve Controller Application Manual QUCM Limitorque Controller Installation and Programming Manual This Manual describes the QUCM application for interfacing Limitorque Valve Actuators

More information

Industrial 1-port RS422/485 Modbus Gateway

Industrial 1-port RS422/485 Modbus Gateway Industrial 1-port RS422/485 Serial Interface One RS422/485 port with 5-contact terminal block Cost effective for RS422/ to Fast Ethernet 10/100BASE- TX application Supports 4-wire RS422 or 2-wire with

More information

Analog Current Input - 16 Channel IC693ALG223. Current Ranges. Power Requirements and LEDs. Location in System. Analog Input Modules

Analog Current Input - 16 Channel IC693ALG223. Current Ranges. Power Requirements and LEDs. Location in System. Analog Input Modules Analog Input Modules Analog Current Input - 16 Channel IC693ALG223 The 16-Channel Analog Current Input module provides up to 16 single-ended input channels, each capable of converting an analog input signal

More information

Measurement Systems Datascan Installation and User Guide

Measurement Systems Datascan Installation and User Guide Measurement Systems Datascan Installation and User Guide Supplied By Contents Contents 1. INTRODUCTION... 1 1.1 GENERAL... 1 1.2 DATASCAN MODULE RANGE... 1 1.2.1 Measurement Processors... 1 1.2.2 Analog

More information

Ethernet/IP Module. User Manual. Contents

Ethernet/IP Module. User Manual. Contents User Manual Contents 1 Important User Information... 2 2 Installation... 3 3 Connection... 4 4 Device Configuration... 5 5 Operation... 8 6 Packet Structures... 9 7 Network Design... 18 8 Specifications...

More information

NetBiter Serial Server User Manual

NetBiter Serial Server User Manual User Manual IntelliCom Innovation AB Linjegatan 3D SE-302 50 Halmstad SWEDEN Phone +46 35 18 21 70 Fax +46 35 17 29 09 email info@intellicom.se web www.intellicom.se Revision List Revision Date Author

More information

HRT-710. User s Manual Version HRT-710 User Manual (Version 1.23, Dec/2012) PAGE: 1

HRT-710. User s Manual Version HRT-710 User Manual (Version 1.23, Dec/2012) PAGE: 1 TM HRT-710 User s Manual Version 1.23 HRT-710 User Manual (Version 1.23, Dec/2012) PAGE: 1 Warranty All products manufactured by ICP DAS are under warranty regarding defective materials for a period of

More information

MPCR Series DeviceNet Technical Manual TDMPCRDNTM2-0EN 01/08 Subject to change without notice

MPCR Series DeviceNet Technical Manual TDMPCRDNTM2-0EN 01/08 Subject to change without notice MPCR Series DeviceNet Technical Manual Table of Contents MPCR Series Introduction... 3 Product Overview... 3 About DeviceNet... 4 Overview... 4 MPCR DeviceNet Features... 4 Cabling and Drop Line Lengths

More information

isma-b-mg-ip User Manual Global Control 5 Sp. z o.o. Poland, Warsaw

isma-b-mg-ip User Manual Global Control 5 Sp. z o.o. Poland, Warsaw isma-b-mg-ip User Manual Global Control 5 Sp. z o.o. Poland, Warsaw www.gc5.pl Table of content 1 Introduction... 4 1.1 Revision history... 5 1.2 Safety rules... 5 1.3 Technical specifications... 6 1.4

More information

QUICK SETUP GUIDE. BCM2 Series Branch Circuit Monitors. Safety Information. Equipment Maintenance and Service. Raritan DANGER!

QUICK SETUP GUIDE. BCM2 Series Branch Circuit Monitors. Safety Information. Equipment Maintenance and Service. Raritan DANGER! QUICK SETUP GUIDE BCM2 Series Branch Circuit Monitors Safety Information DANGER! HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH Follow safe electrical work practices. See NFPA 70E in the USA, or applicable

More information

P USB 2.0 (Type B) Port - Programming - Online monitoring

P USB 2.0 (Type B) Port - Programming - Online monitoring P3-0 CPU Module Company Information Systems Overview P3-0 The P3-0 is a full-featured, highperformance CPU. Features include a line x 10 character LCD and seven communications ports which support

More information

GW-7238D J1939 to Modbus TCP Server / RTU Slave Gateway

GW-7238D J1939 to Modbus TCP Server / RTU Slave Gateway GW-7238D J1939 to Modbus TCP Server / RTU Slave Gateway User s Manual www.icpdas.com 1 Warranty All products manufactured by ICP DAS are under warranty regarding defective materials for a period of one

More information

EasyIO FC20 User Reference v1.3. EasyIO FC 20 DDC User Reference V1.3

EasyIO FC20 User Reference v1.3. EasyIO FC 20 DDC User Reference V1.3 EasyIO FC 20 DDC User Reference V1.3 Document Change Log 1 st April 2013 Document created. 13 th July 2013 Software configurations added. 27 th Sept 2014 FC now support pulse input. 6 th June 2015 Serial

More information

Advantys ETB. DATA SHEET Advantys ETB IP 67 Ethernet Digital I/O Modules. Description. Features

Advantys ETB. DATA SHEET Advantys ETB IP 67 Ethernet Digital I/O Modules. Description. Features Advantys ETB DATA SHEET Advantys ETB IP 67 Ethernet Digital I/O Modules The Advantys ETB family of IP 67 digital I/O modules with direct connection to the Ethernet ( Modbus TCP/IP ) Communication Network.

More information

LT900SERIES. 1xN Multi-Channel Switch Operation Manual

LT900SERIES. 1xN Multi-Channel Switch Operation Manual LT900SERIES 1xN Multi-Channel Switch Operation Manual Table of Contents General Information.. 1 General Specifications...... 2 Interface Connectors..... 3 Connector Assignment 16 pin........ 4 26 pin....

More information

Smart Wireless THUM Adapter

Smart Wireless THUM Adapter Reference Manual Smart Wireless THUM Adapter www.rosemount.com Reference Manual Smart Wireless THUM Adapter Smart Wireless THUM Adapter Smart Wireless THUM Adapter Hardware Revision 1 HART Device Revision

More information

QUICK SETUP GUIDE PMC-1000, PMC-1001, PMM-1000, PMB-1960, PMMC-1000 PM Series Power Meter

QUICK SETUP GUIDE PMC-1000, PMC-1001, PMM-1000, PMB-1960, PMMC-1000 PM Series Power Meter QUICK SETUP GUIDE PMC-1000, PMC-1001, PMM-1000, PMB-1960, PMMC-1000 PM Series Power Meter Safety Information DANGER! HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH Follow safe electrical work practices.

More information

P1-540 CPU. CPU Specifications

P1-540 CPU. CPU Specifications CPU Specifications User Memory 0MB (Includes program, data and documentation) Memory Type Flash and Battery Backed RAM Retentive Memory 00kB Scan Time 1.3 ms (1K Boolean, 12 I/O) External Power Required*

More information

MODBUS TCP MODULE INSTRUCTIONS. for use with WSIQ2/WSE

MODBUS TCP MODULE INSTRUCTIONS. for use with WSIQ2/WSE INSTRUCTIONS MODBUS TCP MODULE for use with WSIQ2/WSE WorldWide Electric Corporation Phone: 1-800-808-2131 Fax: 1-800-711-1616 www.worldwideelectric.net Product Compatibility This communications module

More information

1 port RS-232 Device Server

1 port RS-232 Device Server 1 port RS-232 Device Server Ethernet RJ45 1 Port Transmit and receive and Ethernet Link and 100/10M LED drive. 10/100 Mbps, auto MDI/MDIX Gateway IP address Serial Interface 1 Port 15 KV ESD protection

More information

RTU32S RTU32S Series Small Compact Utility RTU

RTU32S RTU32S Series Small Compact Utility RTU RTU32S RTU32S Series Small Compact Utility RTU Data Sheet 40270 v1.05 / July 7th, 2014 INTRODUCTION Brodersen Small Compact RTU32S Series with RTU/PLC functionality. The RTU32S series is based on an embedded

More information

T1K MODBUS Base Controller Specifications

T1K MODBUS Base Controller Specifications Base Controller 1 2 In This Chapter.... Base Controller Setting the DIP Switches Setting the Rotary Address Switches Port Pin out and Wiring RJ12 Serial Port Pin out and Wiring 2 2 Base Controller General

More information

Weight ounces Panel Fasteners... Four holes to accept four 16x32 machine screws NEMA Rating... NEMA 1

Weight ounces Panel Fasteners... Four holes to accept four 16x32 machine screws NEMA Rating... NEMA 1 8 Panel Specifications: In this section, you will be given all of the information you need to install the panel. Before actually installing the OP-9001 panel, it may be helpful to examine the specifications

More information

USR-TCP Hard version: V2.0 File version: V

USR-TCP Hard version: V2.0 File version: V Serial Device Server - RS232/RS485 to Ethernet converter USR-TCP232-300 Hard version: V2.0 File version: V1.1 2011-8-17 Serial Device Server - RS232/RS485 to Ethernet converter is an Equipment for convert

More information

PACSystems* RX3i and Series 90*-30 IC694ALG442-CC and IC693ALG442-EC

PACSystems* RX3i and Series 90*-30 IC694ALG442-CC and IC693ALG442-EC January 214 MODULE K USER SUPPLY IC694ALG442 I1 I2 I3 I4 Q1 Q2 PACSystems* RX3i and Series 9*-3 IC694ALG442-CC and IC693ALG442-EC Analog Module, 4 Inputs/2 Outputs, Current/Voltage Analog Current/Voltage

More information

NetBiter I/O Extender User Manual

NetBiter I/O Extender User Manual User Manual Part no. 0920-9999-009 IntelliCom Innovation AB Pilefeltsgatan 73 SE-302 50 Halmstad SWEDEN Phone +46 35 17 29 90 Fax +46 35 17 29 09 email info@intellicom.se www www.intellicom.se Revision

More information

Serial Connection of HC900 Hybrid Controller to 900CS Control Station

Serial Connection of HC900 Hybrid Controller to 900CS Control Station Note: Ethernet connections will provide faster performance than RS-485 HC900 1. Remove HC900 CPU and set S2 Dip Switches for RS-485 unterminated Replace CPU & follow instructions per Installation and User

More information

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

See instructions to download and install the latest version of LinkBoxMB and the user's manual at Safety Instructions WARNING Follow carefully this safety and installation instructions. Improper work may lead to serious harmful for your health and also may damage seriously the IntesisBox and/or any

More information

POWERWISE INDAC SETUP MANUAL

POWERWISE INDAC SETUP MANUAL POWERWISE INDAC SETUP MANUAL REVISION: 2.2 INDAC & EMONITOR GATEWAY An installation guide for the PowerWise indac. 2013 PowerWise, Inc. This manual may contain proprietary information about the product

More information

Redundant System Redundant System P9-1-1

Redundant System Redundant System P9-1-1 .. P-- Overview - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - P-- idcs-8830/idcs-8830r - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

More information

NCOM SERIAL DEVICE SERVER 1XX SERIES USER S MANUAL

NCOM SERIAL DEVICE SERVER 1XX SERIES USER S MANUAL NCOM SERIAL DEVICE SERVER 1XX SERIES USER S MANUAL 2017-07-07 Edition Titan Electronics Inc. Web: www.titan.tw Contents 1. INTRODUCTION... 4 1.1 Key Features... 5 1.2 Specifications... 6 2. PANEL LAYOUT

More information

P3-RS Remote Slave Module

P3-RS Remote Slave Module P3-RS Rack with CPU Module Racks with P3-RS Modules The P3-RS is a full-featured, highperformance, Remote Slave module. Features include a line x 0 charactor LCD display and five communications ports

More information

Anybus Communicator STARTUP GUIDE. IIoT. SP en-us ENGLISH

Anybus Communicator STARTUP GUIDE. IIoT. SP en-us ENGLISH Anybus Communicator IIoT STARTUP GUIDE ENGLISH Important User Information Liability Every care has been taken in the preparation of this document. Please inform HMS Industrial Networks AB of any inaccuracies

More information

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

See instructions to download and install the latest version of LinkBoxMB and the user's manual at Safety Instructions WARNING Follow carefully this safety and installation instructions. Improper work may lead to serious harmful for your health and also may damage seriously the IntesisBox and/or any

More information

Profinet Module. User Manual. Contents

Profinet Module. User Manual. Contents User Manual Contents 1 Important User Information... 2 2 Installation... 3 3 Connection... 4 4 Device Configuration... 5 5 Operation... 7 6 Packet Structures... 8 7 Network Design... 16 8 Specifications...

More information

Embedded Modbus TCP Module GS11-MT. User Manual REV 1.1. SST Automation.

Embedded Modbus TCP Module GS11-MT. User Manual REV 1.1. SST Automation. Embedded Modbus TCP Module GS11-MT User Manual REV 1.1 SST Automation E-mail: SUPPORT@SSTCOMM.COM WWW.SSTCOMM.COM Catalog 1 About the Embedded Module... 4 1.1 General...4 1.2 Features... 4 1.3 Specifications...4

More information

QUICK SETUP GUIDE. BCM2 Series Branch Circuit Monitors. Safety Information. Equipment Maintenance and Service. Product Overview. Raritan DANGER!

QUICK SETUP GUIDE. BCM2 Series Branch Circuit Monitors. Safety Information. Equipment Maintenance and Service. Product Overview. Raritan DANGER! QUICK SETUP GUIDE BCM2 Series Branch Circuit Monitors Safety Information DANGER! HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH Follow safe electrical work practices. See NFPA 70E in the USA, or applicable

More information

BL compact multiprotocol fieldbus station for Industrial Ethernet 8 Analog Inputs for Current or Voltage BLCEN-8M12LT-4AI-VI-4AI-VI

BL compact multiprotocol fieldbus station for Industrial Ethernet 8 Analog Inputs for Current or Voltage BLCEN-8M12LT-4AI-VI-4AI-VI On-machine Compact fieldbus I/O block EtherNet/IP, Modbus TCP, or PROFINET slave Integrated Ethernet Switch 10 Mbps / 100 Mbps supported Two 4-pole M12, D-coded, connectors for fieldbus connection 2 rotary

More information

DATRAN XL4 PLUS RTU Quick Start Guide

DATRAN XL4 PLUS RTU Quick Start Guide DOC-QSG-XL4-PLUS-RTU DATRAN XL4 PLUS RTU Quick Start Guide Configuring the XL4 Plus RTU The XL4 Plus RTU is configured using software called QTech Workbench. Connection to your PC is via a USB cable (Type

More information

MODEL: R3-NE1. Remote I/O R3 Series. ETHERNET INTERFACE MODULE (Modbus/TCP) 27.5 (1.08)

MODEL: R3-NE1. Remote I/O R3 Series. ETHERNET INTERFACE MODULE (Modbus/TCP) 27.5 (1.08) MODEL: R-NE Remote I/O R Series ETHERNET INTERFACE MODULE (Modbus/TCP) 7. (.8) 9 (.9) (.) mm (inch) MODEL: R-NE-[][] ORDERING INFORMATION Code number: R-NE-[][] Specify a code from below for each [] and

More information

PACSystems* RX3i IC695CMM002-EG and IC695CMM002CA-EG IC695CMM004-EG, IC695CMM004CA-EG, and IC695CMM004LT-EG

PACSystems* RX3i IC695CMM002-EG and IC695CMM002CA-EG IC695CMM004-EG, IC695CMM004CA-EG, and IC695CMM004LT-EG September 2017 PACSystems* RX3i IC695CMM002-EG and IC695CMM002CA-EG IC695CMM004-EG, IC695CMM004CA-EG, and IC695CMM004LT-EG Serial Communications Modules PACSystems* RX3i Serial Communications modules expand

More information

SmartMod DC Digital Input Module HE359DIM610 12/24VDC Negative Logic

SmartMod DC Digital Input Module HE359DIM610 12/24VDC Negative Logic MAN0842-02 DIM610 PAGE 1 of 6 SmartMod DC Digital Input Module HE359DIM610 12/24VDC Negative Logic 1 SPECIFICATIONS Number of Channels Input Ranges DIM610 12 PLC Update Rate 12/24 VDC Terminal Type DIM610

More information

GEM80 & ewon Setup Quick Guide

GEM80 & ewon Setup Quick Guide Introduction to the ewon The ewon is an intelligent, programmable Ethernet Gateway, which can be used to bridge GEM 80 PLCs onto an Ethernet network, via the PLC serial port (Port3). This provides network-based

More information

CAN Fiber Optic Modem

CAN Fiber Optic Modem User Manual for the HE200CFM100 CAN Fiber Optic Modem Second Edition 17 September 1999 MAN0007-02 PREFACE 17 SEPT 1999 PAGE 3 PREFACE This manual explains how to use the Horner APG s CAN Fiber Optic Modem.

More information

BCM2 Series Branch Circuit Monitors Quick Setup Guide

BCM2 Series Branch Circuit Monitors Quick Setup Guide BCM2 Series Branch Circuit Monitors Quick Setup Guide Safety Information DANGER! HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH Follow safe electrical work practices. See NFPA 70E in the USA, or applicable

More information

GE Fanuc IC694ALG221. Rx3i PacSystem

GE Fanuc IC694ALG221. Rx3i PacSystem GE Fanuc IC694ALG221 http://www.pdfsupply.com/automation/ge-fanuc/rx3i-pacsystem/ic694alg221 Rx3i PacSystem Input module, analog 4 point current. IC694A IC694AL IC694ALG 919-535-3180 sales@pdfsupply.com

More information

Industrial Serial Device Server

Industrial Serial Device Server 1. Quick Start Guide This quick start guide describes how to install and use the Industrial Serial Device Server. Capable of operating at temperature extremes of -10 C to +60 C, this is the Serial Device

More information

USER MANUAL FOR FIOA-0402-U-16

USER MANUAL FOR FIOA-0402-U-16 USER MANUAL FOR FIOA-0402-U-16 COPYRIGHT NOTICE This manual is a publication of Renu Electronics Pvt. Ltd. and is provided for use by its customers only. The contents of the manual are copyrighted by Renu

More information

PORT MULTIPLEXER USER S MANUAL

PORT MULTIPLEXER USER S MANUAL PORT MULTIPLEXER USER S MANUAL Contents Preliminary i Manual Revisions ii INTRODUCTION. Purpose of this Manual. Introduction to Port Multiplexer. Port Multiplexer Applications:. Port Multiplexer Specifications

More information

RTU560 Connections and Settings DIN Rail RTU 560CIG10

RTU560 Connections and Settings DIN Rail RTU 560CIG10 Connections and Settings DIN Rail RTU 560CIG10 Application, characteristics and technical data have to be taken from the hardware data sheet: 560CIG10 1KGT 150 719 Operation The 560CIG10 is a DIN rail

More information

Modbus TCP/RTU Gateway

Modbus TCP/RTU Gateway Modbus TCP/RTU Gateway Hardware Installation Guide for models IE-GW-MB-2TX-1RS232/485 IE-GWT-MB-2TX-1RS232/485 Second Edition, June 2014 1516600000/01/06.14 Important note: The detailed user manual, additional

More information

USER MANUAL. Longo programmable controller LPC-2.MC8 Main module. Version 10

USER MANUAL. Longo programmable controller LPC-2.MC8 Main module. Version 10 USER MANUAL Longo programmable controller LPC-2.MC8 Main module Version 10 SMARTEH d.o.o. / Poljubinj 114 / 5220 Tolmin / Slovenia / Tel.: +386(0) 388 44 00 / e-mail: info@smarteh.si / www.smarteh.si Written

More information

It is the installer's responsibility to follow all instructions in this manual and to follow correct electrical practice.

It is the installer's responsibility to follow all instructions in this manual and to follow correct electrical practice. MCD Modbus Module Instructions Important User Information INSTALLATION INSTRUCTIONS: MCD MODBUS MODULE Order Code: 175G9000 1. Important User Information Observe all necessary safety precautions when controlling

More information

WIZ220IO / WIZ220IO-EVB User s Manual (Ver. 1.0)

WIZ220IO / WIZ220IO-EVB User s Manual (Ver. 1.0) [ 텍스트입력 ] WIZ0IO / WIZ0IO-EVB User s Manual (Ver. 1.0) 010 WIZnet Inc. All Rights Reserved. For more information, visit our website at www.wiznet.co.kr Document History Information Revision Data Description

More information

DATA CONNECT ENTERPRISE

DATA CONNECT ENTERPRISE DATA CONNECT ENTERPRISE User s Manual IG202T and IGV23 Modem Document Number 520-01005-001 Rev. A DATA CONNECT Contents Contents... iii Figures... iv Chapter 1 Introduction... 5 Features...6 Applications...7

More information

Installation & Operation Guide

Installation & Operation Guide Installation & Operation Guide (Shown with optional Override Board Cover) KMD-5831 Programmable Loop Controller PLC-28 Direct Digital Controller 902-019-04B 1 Introduction This section provides a brief

More information

BACnet-over-Ethernet (BACnet TCP/IP) Gateways for Modbus RTU Devices

BACnet-over-Ethernet (BACnet TCP/IP) Gateways for Modbus RTU Devices Issue Date March 1, 2018 BMGE Series BACnet-over-Ethernet (BACnet TCP/IP) Gateways for Modbus RTU Devices General The BMGE Series BACnet-over-Ethernet (BACnet TCP/IP) gateways, which route communication

More information

Ethernet Interface Module

Ethernet Interface Module Interface Manual 1 Ethernet Interface Module SignalFire Number: ENET-DIN The SignalFire Ethernet Gateway has the following features: - Wide range DC power input. 6 to 36VDC - Power Over Ethernet (POE)

More information

PACSystems* RX3i and Series 90*-30 IC694ALG223 and IC693ALG223

PACSystems* RX3i and Series 90*-30 IC694ALG223 and IC693ALG223 May 2014 PACSystems* RX3i and Series 90*-30 IC694ALG223 and IC693ALG223 Analog Current Input Module 16 Channel The PACSystems* RX3i/Series 90* 16-Channel Analog Current Input module provides 16 single-ended

More information