1 Endoscopes Inspection Report Sale: 1406 Date: 13 / 05 / 2014 (Condition Reports for other items at the end of the Scopes Report) These reports are compiled by our Medical Engineering Team & are for guidance only; all lots are sold as seen, as per our Conditions of Sale. We recommend that wherever possible you inspect lots prior to purchase. Lot Description Condition 110 OLYMPUS CF-1T200L Video Scope 1600x15mm 111 OLYMPUS CYF-4A Direct View 350x5.54mm 112 FUJINON UG1-FP2 Direct View 1000x10.30mm 113 OLYMPUS BF TYPE P30 Insertion tube Good condition Bending mechanism & Angulation control Good movements and locks Light guide cable & Light transmission Both light channels are functional Objective lens and focusing Functional Remote control switches Functional Distal end Good Image Quality Good image Working Channel (s) Clear Leak test Pass Over all condition Overall physical condition and image quality are good Insertion tube Good condition Bending mechanism & Angulation control Good movements and locks Light guide cable & Light transmission Both light channels are functional Objective lens and focusing Functional Remote control switches N/A Distal end Good condition Image Quality Good image Working Channel (s) Clear Leak test Pass Over all condition Overall physical condition and image quality are good Insertion tube Fair condition Bending mechanism & Angulation control Good movements and locks Light guide cable & Light transmission Both light channels are functional Objective lens and focusing Functional Remote control switches N/A Distal end Average condition as some physical damage is present Image Quality Fair image Working Channel (s) Clear Leak test Leaking Over all condition Overall physical condition and image quality are in fair condition but scope is leaking Insertion tube Fair condition but has kinks on the insertion tube near the control box Bending mechanism & Angulation control Good movements Light guide cable & Light transmission Both light channels are functional Objective lens and focusing Functional Remote control switches N/A Distal end Good condition

2 Direct View 540x5.58mm 114 OLYMPUS CYF-4A Direct View 350x5.65mm 115 OLYMPUS CYF-4 Direct View 350x5.78mm 116 OLYMPUS BF TYPE 240 Video Scope 500x6.20mm 117 OLYMPUS CYF TYPE 240 Image Quality Poor image with 50+ fibres missing and water damage Working Channel (s) Clear Leak test Fail - Leaking Over all condition Overall physical condition is fair but the image is poor, water damage is visible and has 50+ fibres missing Insertion tube Fair condition but has a kink on the insertion tube near the control box and there is a dent near the distal end Bending mechanism & Angulation control Good movements and locks Light guide cable & Light transmission Both light channels are functional Objective lens and focusing Functional Remote control switches N/A Distal end Good condition Image Quality Good image Working Channel (s) Clear Leak test Pass Over all condition Overall physical condition is fair but the image is good Insertion tube Good condition Bending mechanism & Angulation control Good movements and locks Light guide cable & Light transmission Both light channels are functional Objective lens and focusing Functional Remote control switches N/A Distal end Good condition Image Quality Good image Working Channel (s) Clear Leak test Pass Over all condition Overall physical condition is good and the image quality is good Insertion tube Fair condition but dent along the insertion tube Bending mechanism & Angulation control Good movements and locks Light guide cable & Light transmission Both light channels are functional Objective lens and focusing Functional Remote control switches Functional Distal end Good condition Image Quality Image is average but the light does not focus and therefore shows bright regions on the output image Working Channel (s) Clear Leak test Pass Over all condition Overall physical condition is fair but the image quality is poor as the light is not focused and shows bright patches Insertion tube Fair condition but has a kink near the control box Bending mechanism & Angulation control Movements and locks are functional but is stiff Light guide cable & Light transmission Both light channels are functional Objective lens and focusing Functional Remote control switches Not functional Distal end Good condition

3 Video Scope 350x5.75mm 118 OLYMPUS CYF TYPE 240 Video Scope 350x5.65mm 119 OLYMPUS CYF TYPE 240 Video Scope 350x5.48mm 120 OLYMPUS CF-200S Videoscope 600x14.80mm 121 OLYMPUS CF-240AL Videoscope 1600x12.90mm Image Quality Image is poor as the image is blurred Working Channel (s) Clear Leak test Fail- Leaking Over all condition Overall physical condition is fair but the image quality is poor as the image is blurred and the scope is leaking Insertion tube Fair condition but has a kink near the control box Bending mechanism & Angulation control Good movements and locks Light guide cable & Light transmission Both light channels are functional Objective lens and focusing Functional Remote control switches Functional Distal end Good condition Image Quality Good image Working Channel (s) Clear Leak test Pass Over all condition Overall physical condition is fair and the image quality is good. Insertion tube Good condition Bending mechanism & Angulation control Good movements and locks Light guide cable & Light transmission Both light channels are functional Objective lens and focusing Functional Remote control switches Functional Distal end Good condition Image Quality Good image Working Channel (s) Clear Leak test Pass Over all condition Overall physical condition is fair and the image quality is good. Insertion tube Satisfactory condition Bending mechanism & Angulation control Good movement and locks Light guide cable & Light transmission Good Objective lens and focusing Good optics Remote control switches Fully functional Distal end Satisfactory condition Image Quality Good image Working Channel (s) Clear Leak test Pass Over all condition Satisfactory overall condition Insertion tube Good condition Bending mechanism & Angulation control Good movement and locks Light guide cable & Light transmission Good Objective lens and focusing Good optics Remote control switches Fully functional Distal end Satisfactory condition Image Quality Good image Working Channel (s) Clear Leak test Pass

4 122 OLYMPUS BF-P30 Direct view 500x5.30mm 123 OLYMPUS SIF-230 Videoscope 2000x12.00mm 124 OLYMPUS CF-240AL Videoscope 1600x13.0mm 125 OLYMPUS CF-H260AZL Videoscope Over all condition Good overall condition Insertion tube Good condition Bending mechanism & Angulation control Good movement Light guide cable & Light transmission Good Objective lens and focusing Satisfactory Remote control switches N/A Distal end Good condition Image Quality Below satisfactory, bad water damage to whole image and 25+ fibres missing Working Channel (s) Clear Leak test Leaking Over all condition Below satisfactory overall condition as scope has water damage and 25+ fibres missing to image, also the scope is leaking Insertion tube Satisfactory condition Bending mechanism & Angulation control Good movement and locks Light guide cable & Light transmission Good Objective lens and focusing Good optics Remote control switches Fully functional Distal end Satisfactory condition Image Quality Good image Working Channel (s) Clear Leak test Leaking when movement controls are moved to maximum Over all condition Good overall condition, however there is a leak when movement controls are moved to maximum Insertion tube Very good condition Bending mechanism & Angulation control Good movement and locks Light guide cable & Light transmission Good Objective lens and focusing Good optics Remote control switches Fully functional Distal end Satisfactory condition Image Quality Good image Working Channel (s) Clear Leak test Pass Over all condition Very good overall condition Insertion tube Very good condition Bending mechanism & Angulation control Good movement and locks Light guide cable & Light transmission Good Objective lens and focusing Unable to test as do not have the correct pigtail to test with Remote control switches Unable to test as do not have the correct pigtail to test with Distal end Satisfactory condition Image Quality Unable to test as do not have the correct pigtail to test with Working Channel (s) Clear Leak test Leaking

5 1600x14.10mm Over all condition Good physical condition, unable to test scopes working condition as do not have the correct pigtail to test with. The scope however is leaking 126 OLYMPUS GIF-PQ20 Insertion tube Satisfactory physical condition slightly stained in colour and slight dent near bottom of insertion tube Bending mechanism & Angulation control Good movement and locks Direct view Light guide cable & Light transmission One of the light outputs is not functional Objective lens and focusing Good optics, however there are 15 fibres missing from image Remote control switches N//A Distal end Satisfactory physical condition Image Quality Satisfactory image as there are 15 fibres missing from image Working Channel (s) Clear 1000x9.90mm 127 OLYMPUS PCF-230 Videoscope 1300x12.0mm 176 VISION SCOPE - Direct View 280x3.22mm 177 VISION SCIENCES ENT 2000 Leak test Leaking Over all condition Below satisfactory physical condition, 15 fibres missing from image, one of the light outputs is not functional and scope is leaking Insertion tube Good condition Bending mechanism & Angulation control Good movement and locks Light guide cable & Light transmission Good Objective lens and focusing Good optics Remote control switches Fully functional Distal end Satisfactory condition Image Quality Good image Working Channel (s) Clear Leak test Leaking Over all condition Good condition, scope is leaking Insertion tube Poor condition where there is a dent along the tube, kinks near the control box and the outer insulating sheath near the distal end is missing Bending mechanism & Angulation control Good movements Light guide cable & Light transmission Both light channels are functional Objective lens and focusing Functional Remote control switches N/A Distal end Fair condition Image Quality Fair image but there is slight water damage visible on the image near the edge Leak test Unable to test as there is no connector at time of testing Over all condition Overall physical condition is poor due to the condition as the insertion tube but the image is fair but slight water damage is visible Insertion tube Poor condition where there is a dent along the tube and kinks near the control box Bending mechanism & Angulation control Good movements Light guide cable & Light transmission Light channels are functional

6 Direct View 300x3.49mm 181 OLYMPUS CYF-4A Direct View 350x5.56mm Objective lens and focusing Functional Remote control switches N/A Distal end Good condition Image Quality Good image Leak test Pass Over all condition Overall physical condition is poor but the image quality is good Insertion tube Good condition Bending mechanism & Angulation control Good movements and locks Light guide cable & Light transmission Both the light channels are functional Objective lens and focusing Functional Remote control switches N/A Distal end Good condition Image Quality Good image Working Channel - Clear Leak test Pass Over all condition Overall physical condition is good and the image quality is good

7 Condition Report Sale: 1406 Date: 13 / 05 / 2014 These reports are compiled by our Medical Engineering Team & are for guidance only; all lots are sold as seen, as per our Conditions of Sale. We recommend that wherever possible you inspect lots prior to purchase. Lot Description Number 1 Datascope System 98XT Balloon Pump with 1x Box of Acessories 2 Zeiss Operating Microscope 3 Haag-Streit 900 Slit Lamp with Table and Accessories Case 4 Drager Fabius Anaesthetic Machine Report Powers up display screen and control panel are in good working order and the printer is also functional. Doppler is included and the gas cylinder and adult condensate removal/safety disk are in place. Overall the unit is in good physical condition. Not fully tested. Includes manual, ECG lead set and a spare gas cylinder. Operating hours: The operating microscope powers up, with unit able to produce a good light output. The mechanical movements and locks are in working order. The operating microscopes optical system shows to produce a clear image, with unit showing to have good focusing with the magnification functional. The unit is in fair physical condition. The slit lamp is able to power up, with it able to produce a light output. The fixation light is in place and shows to function. Units joystick movements shows to be freely movable, with its lock functional. Units chin rest is in place and its chin adjustment is in working order. The slit lamps tables mechanical height adjustment is in working order. The slit lamp is missing its eyepieces, however a set of eyepieces were used for tested purposes and showed the rest of the optical system to be able to produce a clear image. Overall the slit lamp is in satisfactory physical condition, with the side compartment on the table missing its door. The anaesthetic machine was tested using a medical compressor and the anaesthetic machine showed to have its gauges and flow meters in working order. The anti-hypoxic safety feature is in working order and the O2 flush is functional. The gas cut off alarm is functional. The anaesthetic machine includes O2, air and N2O hoses. The unit is in good physical condition. Manufacture date: Zeiss OPMI-1 Operating Microscope The power supply comes on and all the selected outputs power is working. The lamp is working fine. The optical system needs cleaning up but still with fair magnification and focus. All mechanical movements and locks are functional. Magnification range 0.4 to 2,5 and eye pieces 12,5x. Objective lens f=200. System is in fair overall physical condition.

8 7 Medtronic Lifepak 20 Defib With ECG Leads x1 8 Aloka Echo Camera SSD-500 Ultrasound with Probe Aloka 7.5MHz 10 Pfizer Valleylab Force 30 Diathermy (No Foot Switch) 16 Zoll M Series Defibs x 2 24 Wolf Stack Trolley With Panasonic M2080 Monitor, Wolf 5512 Processor, Wolf 5124 Light Source, Wolf Camera Head and Wolf 2232 Laparo CO2 Insufflator The defibrillator powers up well and passed its initial self-test. The display, functions and function buttons are in good working order. The defibrillator is testes using a defibrillator analyser and the output energies are within the limits. The AED and manual mode are in good working order. The ECG signal is tested using an ECG simulator and, the defibrillator appears to give good strong traces of ECG signals. Pacer option is included, which has not been fully tested but appears to be functional. Printer is functional. The service indicator stays on. Includes III lead ECG, AED therapy cable and two defibrillator pads (expire 03/2014 and 04/2014). The overall physical condition is reasonable. The defibrillator is a Biphasic unit and its Y.OM is The ultrasound powers up well and passed its initial self-test. The display, functions and function buttons are in good working order. The ultrasound is tested using a phantom and set measurements taken are within the limits. The resolution is average. Ultrasound includes modes B and M, which are in good working order. The probe (model: UST- 5512U-7.5MHz) is in good physical condition and is intact. Overall physical condition is fair. The diathermy powers up well and passed its initial self-test. The display and function buttons are in good working order. Some of the function buttons has some wear and tear. The diathermy has not been fully tested but the patient monitoring system is in good working order. No footswitches are included. Overall physical condition is reasonable. Both the defibrillators powers up well, its display, functions and function buttons are in good working order. The defibrillators have been tested using a defibrillator analyser and the output energies are within the limits. The ECG is tested using an ECG simulator and the defibrillators give good strong traces of ECG signals. The pacer option is included, which has not been fully tested but appear to be functional. The printer is functional. The defibrillators include two batteries which appear to be flat and are in need of charge. Two AED therapy cables are included but no ECG leads are included. Overall physical condition is reasonable. All units power up. The processor and camera head are able to produce a satisfactory image on the Panasonic monitor, with the camera head also showing to have satisfactory focusing. The light source is able to produce a good light output, with its brightness adjustment in working order. The insufflator has not been tested but is able to power up ok. Overall lot is in satisfactory physical condition.

9 25 Smith and Nephew Stack System Sony Trinitron Monitor PVM-20L2MD, 640 Image System 300 XL Xenon Light Source, CCD Camera Operator and Camera Head, Sony Colour Video Printer UP-21 MD (037097) 28 Philips Intellivue MP70 Patient Monitors x2 29 Datex Capnomac Ultima Patient Monitors x2 30 Penlon AV900 Ventilator 31 Penlon AV900 Ventilator 34 Graseby 3400 Syringe Pump, 3200 Syringe Pump and Ivac P6000 Syringe Pump x2, Dinamap Pro 100V2 Patient Monitor and Nellcor NBP-4000 Patient All units are able to power up. The camera head and processor are able to produce a satisfactory image on the Sony monitor, with the camera head also showing to have satisfactory focusing. The light source is able to produce a good light output with its brightness control functional. The 640 image management system is able to power up and works on the National Display Systems flat screen, but in the boot up unit displays message CMOS checksum error which is able to be passed. Unit is able to power up successfully and shows to be functional. The color video printer is functional. Overall lot is in satisfactory physical condition. Image management system Version: 2.3 The two patient monitor s powers up well and passed its initial selftest. Its display and LCD touchscreen are in good working order. The monitors do no detect the multi-parameter and recorder modules. Therefore unable to carry out any further checks. No leads are included. Overall physical condition is reasonable. Y.O.M is 2004 and Software Versions are: REV B and REV F Both monitors power up ok and the display screens and control panels are in good working order. CO2 functions appear to working but gas monitoring functions have not been tested. Overall the units are in reasonable physical condition. The alarm silence buttons on both monitors have been worn out. The ventilator powers up well and passed its initial self-test. The display, LCD touchscreen and function buttons are in good working order. The unit has not been fully tested but appears to be functional. Oxygen hose is included. Overall physical condition is as there are scratches on the top cover. S/W is V3.11 The ventilator powers up well and passed its initial self-test. The display, LCD touchscreen and function buttons are in good working order. The unit has not been fully tested but appears to be functional. No hoses are included. Overall physical condition is reasonable. S/W is V3.30 One of the IVAC syringe drivers is not powering up neither is the Dinamap. The Nellcor power s up but the display is not displaying anything. The rest of the units included in lot are powering up with their function buttons and displays looking to be in working order. None of the units have been tested. The lot is in fair physical condition, with the Dinamap s printer door missing, and part of the Nellocrs handle missing. No accessories included with lot.

10 Monitor 41 Huntleigh Flowtron Pumps x5 43 Storz Stack Trolley with Storz Monitor. NDS Radiance Monitor, Storz Xenon Nova Light Source, Storz Image Camera Control Unit, Storz CD Re-Writer and Keeler Headset 44 Valley Lab Force 2 Diathermy - No Pedals 45 ATL HDI 5000 Ultrasound with Mitsubishi CP200,C5-2,L12-5 and C8-4V Probes 50 GE Dash 4000 Patient Monitor, Datex Ohmeda S/5 Patient Monitors x2 (Damage to One) Unable to check to units as their plugs are missing, the other three units power up, with pumps looking to function however they have not been fully test. Overall the lot is in reasonable physical condition. All units are able to power up. Unit does not include a camera head so unable to test the processor. The light source is missing its interchangeable light guide adaptor; however the light source is able to produce a good light output. The imaging unit is able to power up, and then is able to open the AIDA compact programme but it fails to fully load as message No dongle found is displayed which is unable to be passed. The head gear is able to power up and is able to produce a light output with its brightness adjustment functional. Overall lot is in satisfactory physical condition. The diathermy has its switch missing, therefore unable to power up and carry out any further checks. No footswitches are included. Overall physical condition is fair. The ultrasound powers up but does not go into its main menu screen, therefore unable to carry out any further checks. The lot includes four probes (models: L7-4, C5-2, L12-5 and C8-4v), which are physically intact but have not been tested. Printer is included, which powers up but has not been tested. Overall physical condition is reasonable. The three patient monitors power up well, and passed its initial selftest. The Dash 4000 powers on for a few minutes but turns itself off; also its display monitor has lines running through the LCD screen. The Datex Ohmeda (S/N: ) has many pixels missing and therefore unable to clearly read the display monitor. The monitor appears to be functional, where it s ECG and NIBP are tested but has not been verified, unable to test the SPO2 as display set up is needed to be accessed but difficult to read the display monitor. This monitor has a number of cracks along the casing and its rotary knob is missing. Recorder is missing but parameters IBP, ECG, SPO2, Temp and NiBP are included. The other monitor (S/N: ) is in good working order where its ECG is fully tested using an ECG simulator and is functional. The NiBP and SPO2 appear to be functional but have not been fully tested. The printer is included and functional. Included parameters NiBP, ECG, SPO2, IBP, CO2 and Temp. Two batteries are included but are flat and in need of a charge. Lot includes x1 AC adaptor but no leads are included. Overall physical condition is average due to usage.

11 65 Datex Ohmeda Aestiva 3000 Anaesthetic Trolley with Ventilator The anaesthetic machine powers up ok and the pressure gauges, flow meters, O2 flush; Basel flow and anti-hypoxic safety feature are all in good working order. The 7900 Smart Vent powers up ok and completes the system self-test successfully. The function buttons are working fine but the display has several pixels out, however the displayed values are not affected. The ventilator was tested with test lung and medical air and the set parameters and alarm limits were working fine. The flow and oxygen sensors are working fine. The absorber, bellows and rebreathing assembly are in good condition with no leak detected during test run. The backup battery for the Smart Vent is functional. Overall, the system is in good physical condition. O2, Air, N2O hoses and AGSS receiver are included 66 SLE 2000 Infant Ventilator with SLE 2100 Respiration Monitor 68 Eschmann TD850 Diathermy with Yellow and Blue Foot Switch on ST80 Suction Trolley and Lina Smoke Evacuator 69 Olympus CLE-4U Light Source and Atlantech Xenon Fibre-Optic Light Smart Vent Software Version: 3.2 The ventilator powers up, with its function buttons and numerical displays in working order. Unit is missing its expiratory block, but one was used for test purposes. The ventilator showed to be functional, when it was tested using a medical compressor. The ventilator showed to be functional in all ventilation modes. Units output has not been verified to see if it is within set limits. Unit oxygen is able to calibrate to 21%. Unit includes O2 and air hoses. The SLE 2100 is able to power up, with it then passing through its initial self-test successfully. Units display is functional and the function buttons look to be responding. The SLE2100 has not been tested. The humidifier is also powering up but again has not been test. The lot is in satisfactory physical condition. Vent modes: SIMV, PTV, CMV and CPAP Operation hours: h The diathermy powers up well, its display, functions and function buttons are in good working order. The diathermy is tested using an ESU analyser and the monopolar (cut and coag) output results are out of limits. Bipolar is not tested as there are no footswitches. Includes monopolar footswitches (cut and coag). The ST 80 suction has its mains cable cut off and therefore unable to fully test. The Lina suction powers up and appears to be functional but has not been fully tested. Overall physical condition is reasonable. Both units are able to power up, however neither unit was able to produce a light output. The Olympus CLE-4U has its air feeding pump functional. Units are in below satisfactory physical condition.

12 Source 70 Medtronic Lifepak 20 x1, Physio Control Lifepak 9 with Shock Advisory Adapter x1 Lifepak 20 The defibrillator is able to power up and is able to pass through its initial self-test successfully. Units function buttons, rotary knob and display are in working order. Unit does not include any paddles but does include (1x) AED cable. Units output was tested using a defibrillator analyser and all readings taken showed to be within set limits. Unit was functional in both manual and AED modes. Unit was able to charge to 360J in manual mode. The defibrillator is biphasic. The audio voice prompts are functional. Unit includes 3 wire ECG leads and units ECG was verified as functional. Units printer is functional but the battery is not. Unit is in good physical condition. Lifepak 9 The defibrillator is able to power up, with its function buttons and display in working order. Unit does not include any paddles but includes a shock advisory adaptor and AED cable. Unit has not been fully tested. Unit was able to give a test output of 360J, but the output has not been verified. Only manual mode has been checked. The shock advisory adaptor has not been checked. Unit includes (1x) 3 wire ECG and units ECG has been verified as functional. Units printer is functional and the battery is low. Unit is in fair physical condition. 74 Drager Oxylog 2000 Portable ventilator 76 Graseby 3200 Syringe Pumps x5, Graseby 3100 Syringe Pumps x3 and Alaris GH Syringe Pump and Abbot Flexiflow Lifepak 9 manufacture date: 1999 Lifepak 12 manufacture date: 2006 Unit power up and system self-test completed successfully. The lithium battery and mains charger is in good working order. LCD and controls are functional. Airways pressure indicator and alarm setting are working fine. The ventilator modes include: IPPV, SIMV, CPAP and SIPPV and they all appears to be functional. Test run with medical air compressor and test lung, indicates that all parameter and alarm settings were in good working order. The minute Volume (MV) was verified with the set valve of Tidal volume and Frequency (BPM) and found to be within limit. The system is in good physical and cosmetic condition. Oxygen hose with schrader connector is included. The Alaris Plus syringe driver is not power up and one of the Graseby 3100 displays fault 86 which is not able to be passed. The rest of the units are able to power up, with their function buttons and displays in working order. Units have not been tested. The lot is in fair physical condition.

13 Enteral Pump 88 Olympus PSD 20 Diathermy with Foot Switch 92 Cardiac Science AED Trainer x2, Lifepak CRT Trainer x1 103 Omega Excel Laser System with 1 x Probe, Manual and Key 142 Smith and Nephew 30º Autoclavable Rigid Scopes x Smith and Nephew 30º Autoclavable Rigid Scopes x Smith and Nephew 30º Autoclavable Rigid Scopes x Smith and Nephew 30º Autoclavable Rigid Scopes x Olympus MAJ-554 Camera Head Unit is able to power up, with it numerical displays in working order and its function buttons looking to respond. Unit has not been tested with its output not checked. Units patient plate alarm is functional. Unit includes (1x) footswitch for monopolar cut/coag, which looks to be responding. Unit is in good physical condition. The lifepak CR-T does not include a battery so unable to determine if the unit is able to power up. Both the Cardiac trainers are able to power up, however only one of the units includes batteries. Both units displays are functional. Both units voice prompts are functional. Both units were tested on a defibrillator analyser, one unit was unable to find a signal the other unit was able to find a signal but then no actual output (0J) was recorded when a shock was delivered. Overall lot is in satisfactory physical condition. The laser unit powers up well and passed its initialization phase. The display, functions and function buttons are in good working order. The beam test was conducted and appears to be in good working order. Includes probe which is in good working order (200mW and lambda 820nm). Key is included. Overall physical condition is fair. Y.O.M 2001 The four rigid scopes appear to be physically intact and are inclined at 30 degrees. Four of the rigid scopes do not produce a good output image. Overall physical condition is reasonable. The four rigid scopes appear to be physically intact and are inclined at 30 degrees. Four of the rigid scopes do not produce a good output image. Overall physical condition is reasonable. The four rigid scopes appear to be physically intact and are inclined at 30 degrees. Four of the rigid scopes do not produce a good output image. Overall physical condition is reasonable. The four rigid scopes appear to be physically intact and are inclined at 30 degrees. Four of the rigid scopes do not produce a good output image. Overall physical condition is reasonable. Unable to test the camera head as there is no processor to test with. The Camera head looks to be intact and in satisfactory physical condition.

14 178 Downs 0 Rigid Scope with Light Lead 183 GE 4C-RS Curved Array Convex Probe 184 GE RNAS-9-RS 3D Micro-Convex Probe 185 GE 11L-D Linear Probe 187 Philips C5-1 Ultrasound Probe - BOFN Qty of Urology Instruments to Inc. Storz Resectoscopes with Obturator, Comeg Cystoscope, Ellick Connectors 195 Aloka UST-9123 Convex Ultrasound Probe 196 Storz Hopkins º Rigid Scope 200 Olympus OTV-S6 Camera Head 235 Pentax LH 150FP Light Source The rigid scope is physically intact and gives a good output image. The light source cable is included which appears to be intact. Overall physical condition is fair. GE Curved Array Convex Probe, 4C-RS (year 2007) -The probe connection, cable and head are intact and in good physical condition; but not tested due to unavailability of suitable unit. The probe is compatible with model GE Logiq e, Vivid e & Vivid i ultrasound system. GE 4D Micro-convex Probe, RNA5-9-RS (year 2009), Frequency range: 3.3 to 9.1 MHz. The probe connection, cable and head are intact and in good physical condition; but not tested due to unavailability of suitable unit. The probe is compatible with model GE Voluson I ultrasound system. Unable to test the probe as there is no ultrasound to test with. The probe looks to be intact and in satisfactory physical condition The probe has not been tested on a compatible ultrasound. Therefore unable to carry out any further tests. Overall physical condition is reasonable but near the scan head it has been taped previously. (Note the probe has been tested on iu22 and HD11XE and was not detected) Lot is in satisfactory physical condition, lot is incomplete consisting of various pieces. The probe is in good physical and cosmetic condition and the scanhead is physically intact. A compatible ultrasound is not available therefore the probe cannot be tested. The rigid scope is physically intact but does not give a good output image. The rigid scope is inclined at 30 degrees. Overall physical condition is fair. Unable to test camera head. The camera head is missing its lens adaptor. The camera head is missing its rubber grommet at the bottom of the camera head causing a large section of the inner insulation to be exposed. The camera head is in below satisfactory physical condition. The light source powers up, with its function knobs in working order. The light source is able to produce a light output with its brightness

15 239 Bayer Clinitek 50 Analysers x2 (1 Spare only) 246 Blease Frontline 690 Anaesthetic Machine with 8200s Ventilator 248 Smith and Nephew Stack Trolley with Sony LCD Monitor, Smith and Nephew 660 HD Image Management System, Dyonics 300XL Xenon Light Source, Smith and Nephew 460P 3-CCD Digital Camera Control Unit, HP Printer and Camera 252 Olympus TK-E1 Trolley with Olympus CV240 Control Unit with Pigtail and Olympus CLV-U20 Light Source 259 Sensor Medics 3100A Oscillatory Ventilator with Fisher and Paykel MR700 Humidifier adjustment functioning. The air pump appears to be functioning. The light source is in fair physical condition for unit s age. Unable to power up units as lot does not include correct power cables. Units are in reasonable physical condition with one unit missing its printer cover. The anaesthetic machine has not been tested but shows to have its flow meters and gauges intact. The ventilator also has not been tested but showed to be able to power up with its numerical displays functioning. Unit s bellows and absorber are in place. Unit includes an AGSS receiving system and hose and a high flow high vacuum regulator and hose. The unit is also complete with O2, air and N2O hoses. Overall the unit is in fair physical condition. All units power up, with the function buttons functional. The camera head and processor produce a satisfactory image on the Sony flat screen monitor, with the camera head also showing to have satisfactory focusing. The light source is able to produce a good light output with its brightness adjustment functional. The image management system showed to have its touch screen display functional with the unit showing to be in working order. The printer powers up. Overall lot is in good physical condition. Image management system version: 1.5 All units on the Olympus trolley power up ok. The light source xenon lamp is working fine and light output model selector (OES, EVIS 100 & EVIS 200) are fully functional. Brightness control in auto and manual mode are working fine. The video processor with the video cable MH977 are in good working order when tested with a videoscope. All the function keys and video controls are working. Good quality image was displayed when connected to a colour monitor. The system is in good overall physical condition. The ventilator is able to power up, with its function buttons/dials and the numerical displays showing to function. The ventilator has not been tested. The oxygen blender monitor is in place but unable to verify if it is powering up. The humidifier is powering up with its function buttons/dial and numerical display functioning, however again unit has not been tested. The ventilator includes O2 and air hoses. Overall the lot is in fair physical condition. Operation hours:

16 260 Sensor Medics 3100A Oscillatory Ventilator with Fisher and Paykel MR700 Humidifier 261 Blease Frontline 440 Anaesthetic Machine with 8200s Ventilator and Marquette Solar 8000 Patient Monitor 265 Nihon Kohden Cardiofax Q ECG Recorder with ECG Lead 266 Nihon Kohden Cardiofax GEM ECG Recorder with ECG Lead 278 Smith and Nephew Stack Trolley with Sony LCD Monitor, Smith and Nephew 660 HD Image Management System, Dyonics Xenon XL Light Source, Smith and Nephew 460P 3-CCD Digital Camera The ventilator is able to power up, with its numerical displays in working order. The silencing alarm function button is not functioning unable to determine if the rest of the function buttons are responding. The ventilator has not been tested. The Air-oxygen blender is in place. The humidifier is powering up but does not appear to be functioning with unit not responding and only displaying EOo on the numerical display. The ventilator includes O2 and air hoses. Overall the lot is in fair physical condition. Operation hours: The anaesthetic machine has not been tested but shows to have its flow meters and gauges intact. The oxygen monitor shows to be powering up with its function buttons and display in working order. The ventilator is also powering up with its numerical displays functioning. Again the ventilator has not been tested. The units bellows and absorber are in place. Unit includes an AGSS receiving system and hose and a high vacuum regulator and hose. The unit is also complete with O2, air and N2O hoses. The patient monitor is able to power up but however does not include any modules, unable to test unit. Overall the lot is in reasonable physical condition. The ECG machine powers up well and passed its initial self-test. The display, functions and function buttons are in good working order. The ECG machine has not been fully tested but appears to be functional. The printer and battery is in good working order. Includes 12 lead ECG wire. Overall physical condition is fair. The ECG machine powers up well and passed its initial self-test. The display, functions and function buttons are in good working order. The ECG machine has not been fully tested but appears to be functional. The printer and battery is in good working order. Includes 12 lead ECG wire. Overall physical condition is fair. All units power up, with function buttons functional. The camera head and the processor are able to produce a good image on the Sony flat screen monitor, with the camera head also showing to have good focusing. The light source is able to produce a good light output with its brightness adjustment functional. However the light sources power switch is loose. The image management system showed to have its touchscreen display in working order with the unit showing to be in working order. The printer powers up. Overall the lot is in satisfactory physical condition. Image management system version: 1.5

17 Control Unit, Camera Head and HP Printer 279 Conmed Excalibur Plus Diathermy on Suction Trolley with Blue, Yellow and Black Foot Switches 280 Conmed Excalibur Plus Diathermy on Suction Trolley with Blue, Yellow and Black Foot Switches 286 Kodak Dryview 8150 Laser Imager 287 Fisher and Paykel Cosy Cot Resusitator 288 Fisher and Paykel Cosy Cot Resuscitator 294 Stryker Resus Trolley The diathermy powers up well and passed its initial self-test. The display, functions and function buttons are in good working order. The diathermy is tested using an ESU analyser and the monopolar (cut and coag) and bipolar output readings are within the limits. However the pure cut mode on the higher output appear to be out of range otherwise all the other modes are within the range. Includes monopolar (cut and coag) and bipolar footswitches. The suction unit powers up but the suction is not functional, therefore unable to carry out any further tests. The overall physical condition is reasonable. The diathermy powers up well and passed its initial self-test. The display, functions and function buttons are in good working order. The diathermy is tested using an ESU analyser and the monopolar (cut and coag) and bipolar output readings are within the limits. Includes monopolar (cut and coag) and bipolar footswitches. The suction is in good working order but output has not been verified. The overall physical condition is reasonable. The unit powers up however the display panel is not functional, so unable to do anything with unit. Unit is in satisfactory physical condition. Unit powers up, with its indication lights and display in working order. Units function buttons are functional however the manual mode function button is missing its button cover. Unit showed to heat up well in Prewarm and manual modes. unit does not include a skin temperature probe. Units overhead light and timer both showed to be functional. The neopuff section of the unit has not been tested. Units electrical height adjustment is in working order. Unit includes O2 and air hoses and a mattress. Overall unit is in satisfactory physical condition. Manufacture date: Unit powers up but immediately alarms and gives an error message Er 017. The error message is unable to be passed. No further checks are able to be carried out on the unit. The neopuff section of the unit has not been tested. Unit include O2 and air hoses and a mattress. Unit is in satisfactory physical condition Manufacture date: The patient trolley is physically intact; its upholstery is in good condition. All articulating movements are in good working order. Its

18 302 Fresenius 4008s Hemofiltration Machine 303 Welch Allyn Patient Monitors on Stands with SPO2 Leads 308 Medelac Saphire 2M and DP Medical Light Source 311 Braun Dialog Dialysis Machine x Braun Dialog Dialysis Machine x Conmed Excalibur Plus Diathermy on Suction Trolley with Blue, Yellow and Black Foot Switches 316 Conmed Excalibur Plus Diathermy on Suction Trolley with Blue, Yellow and Black Foot Switches height adjustment is functional. The side rails are intact. The brakes are in good working order. Overall physical condition is reasonable. Unit is not powering up with unit only able to give a constant alarm. Unit includes modules, double blood pumps, heparin pump, air detector and BiBag. The Bibag module panel cover is completely missing. Unit includes water and drainage hoses. Overall the unit is in fair physical condition. Manufacture date: 2010 Operation hours: The three vital signs monitor power up well, its display, functions and function buttons are in good working order. The NiBP pump and SPO2 is functional but has not been fully tested. Lot includes two NiBP cuffs. Battery is in good working order. Overall physical condition is fair. Medelec Sapphire II. Powers up ok - display screen and controls are in good working order and the printer is also functional. No further checks carried out. Lot includes a DP Medical light source which is in good working order. Overall the unit is in reasonable physical condition. Unable to power up units as both of the mains cables has been removed. Both of the units include (1x) single blood pump, (1x) heparin pump and (1x) air detector. Both of the units have their water and drainage hoses cut off from the bottom. Overall lot is in reasonable physical condition. Unable to power up units as both of the mains cables have been removed. Both of the units include (1x) single blood pump, (1x) heparin pump and (1x) air detector. One of the units includes water and drainage hoses the other unit has its water and drainage hoses missing. Overall lot is in reasonable physical. The diathermy powers up well and passed its initial self-test. The display, functions and function buttons are in good working order. The diathermy is tested using an ESU analyser and the monopolar (cut and coag) and bipolar output readings are within the limits. Includes monopolar (cut and coag) and bipolar footswitches. The suction and its regulator are functional but the output has not been verified. The overall physical condition is reasonable. The diathermy powers up well and passed its initial self-test. The display, functions and function buttons are in good working order. The diathermy is tested using an ESU analyser and the monopolar (cut and coag) and bipolar output readings are within the limits. Includes monopolar (cut and coag) and bipolar footswitches. The suction is

19 317 Drager 5400 Transport Incubator 322 Marquette Mac8 ECG Recorder with ECG Lead 325 Conmed Excalibur Plus Diathermy on Trolley with Yellow, Blue and Black Foot Switches 326 Drager D-Vapour Desflurane Vapouriser functional but the regulator is not functional an unable to change the suction output. The overall physical condition is reasonable. The Transport incubator 5400 power up ok on mains; battery power has not been tested. The incubator set temperature is maintained accordingly. The BabyMix 2 ventilator is in good physical condition but not fully tested. The Oxygen monitor Oxydig has no battery, not tested. The lot is in fair overall ohysical condition. Unit is able to power up after a long period of time. Then the unit shows to have its function buttons in working order. Units display functions however the display flickers which makes it hard to read in places, with some lines of pixels missing. Unit makes a loud constant humming noise. Unit has not been tested. Unit includes 12 wire ECG however all of the leads are missing their end connection pins. Unit is in reasonable physical condition. The diathermy powers up well and passed its initial self-test. The display, functions and function buttons are in good working order. The diathermy is tested using an ESU analyser and the monopolar (cut and coag) and bipolar output readings are within the limits. Includes monopolar (cut and coag) and bipolar footswitches. The overall physical condition is reasonable. The vaporiser is in good physical condition, with its volume control dial and lock intact. There are some minor marks to paintwork. 328 Drager Oxylog Portable Ventilator Unit power up when connected to medical gas. Airways pressure indicator working fine. Test run with medical air compressor and test lung, indicates that all parameter and alarm settings were in good working order. The minute Volume (MV) was verified with the set valve of Tidal volume and Frequency (BPM) and found to be within limit. The system is in fair physical condition. Oxygen hose with schrader connector is included. 361 The ultrasound is unable to power up. Unable to test the unit. Units (1x) probe appears to be physically intact. Unit is in reasonable physical condition, with its covers colour being worn away in large patches. 369 Drager 8000SC Incubator Unit is able to power up, with units function buttons and displays in working order. In Air mode unit showed to be functional, with unit able to reach and maintain the set temperature. Temperature output has not been verified. Unit does not include a skin temperature probe so unable to test skin mode. Humidifier mode has not been checked. Units electrical height adjustment and mechanical cot tilt are in working order. Unit includes a mattress. Unit is in satisfactory physical

20 condition. 374 Edwards Lifescience Aquarius Hemofiltration Machine 379 Sonosite 180 Plus with Probe 382 Zeiss IOL Master with Printer and Table 387 Haag-Streit Slit Lamp with Table 395 Quantel Medical Virdis Twin Laser with Key and Foot Switch, BMBQ Slit Lamp Adaptor Unit is able to power up, units function buttons, rotary knob and display show to be functioning. Unit has not been tested. The blood pump and filtrate cover panel is missing, also the prefillter sensor is bent and unable to close. Overall unit is in fair physical condition. Manufacture date: 2009 Software version: 6 The ultrasound powers on, but is not functional as the display gives a badly flickering display with no actual picture showing. Unable to check unit. Units (1x) probe appears to be physically intact. The ultrasound is in satisfactory physical condition. Manufacture date: The IOL Master powers up well and passed its initial self-test. The display, functions and function buttons are in good working order. The IOL Master is tested using a test eye and test results taken where within the limits. The functions included are Axial Length Measurement, Corneal Curvature Measurement and Anterior Chamber Depth Measurement, which are in good working order. Printer is functional. The height adjustment is in good working order. Overall physical condition is reasonable. IOL Master Version: The slit lamp is able to power up, with it able to produce a light output, the reflector mirror for the light output is in place but has a large chip at one corner. The fixation light is in place but however it is not functional and has its outer cover missing. The joystick movements show to be functioning but however is slightly stiff, the movement lock is functional. The chin rest is in place and its chin adjustment is functional. The slit lamps tables mechanical height adjustment is in working order. The slit lamps optical system is able to produce a clear image, with it also showing to have good focusing. Overall the slit lamp is in satisfactory physical condition, with the side compartment on the table missing its bottom panel. (1x) set of eyepieces (10x) Quantel Medical Viridis Twin, software version: M:10.02 B: Unit power up ok, the LCD screen and function keys are working fine. The aiming beam is working and the 532 nm laser function screen comes when the key is turned on. The parameters were adjustable for power, pulse etc. Test firing of the laser indicate green laser at the out but the power was not verified. When the key is turned to select 810

21 nm laser an error message is displayed E100A:0 fibre disconnected. Only one fibre cable with laser aperture is included with slit lamp adapter model: BMBQ. One YAG safety goggle is included. System is in fair physical condition. 396 Hill-Rom Air Shields Resusitaire Stryker Endoscopy Trolley with Trinitron Monitor Q5000 Light Source, X6000 Light Source, 2 x Sony Colour Video Printer, 2 x 988i 3 Chip Camera Controller and 3 x 988i Camera Heads 400 Alcon Surgical Ultrasonic Imaging System with Monitor and Probe 10MHz and Foot Switch on Trolley 402 Eschmann TD411-S Diathermy with Foot Switches on ST80 Suction Trolley Unit powers up, with its function buttons, indication lights and numeric displays in working order. Unit showed to function with unit able to heat up in pre-warm and manual modes. In manual mode the heat adjustment is functional. Unable to test baby mode as unit does not include a skin temperature probe. Units exam light and timer are both functional. Units electrical height adjustment is functional as is the mechanical cot tilt. Units Suction and patient supply were checked using a medical compressor, and the suction and patient supply showed to be functioning with their gauges in working order. Unit includes O2, air and N2O hoses, unit also includes a mattress and suction jar. Overall unit is in satisfactory physical condition. All units are able to power up, with the function buttons functional. Both of the processors and two of the camera heads are able to produce a good image on the Sony monitor, with both camera heads showing to have good focusing. However one of the two camera heads does show some slight interference from the connection end if moved. The third camera head is able to produce a reasonable image however it is constantly affected with bad interference when the camera head is moved, the camera heads focusing is functional. Both of the light sources are able to produce a good light output with their brightness adjustments functional. Both of the color video printers are powering up. Overall the lot is in satisfactory physical condition. Bulb hours for Q5000: Bulb hours for x6000: 183 Alcon Ultra Scan imaging System, software version: Unit power up ok and the CRT display and keyboard are working fine. The ultrasound probe 10MHz is appears to be working with a scan image display on the screen. Unit is not fully tested. In fair physical condition. The diathermy powers up well and passed its initial self-test. The display, rotary knobs and functions are in good working order. The diathermy is tested using an ESU analyser and cut outputs are out of range whereas the coagulation modes are within the range. The bipolar mode has not been tested as there are no footswitches. Monopolar cut and coagulation footswitches are included. Overall physical condition

Condition Report. Sale /10/ :00:00 - Medical Equipment Auction - PART :00. Sale Date

Condition Report. Sale /10/ :00:00 - Medical Equipment Auction - PART :00. Sale Date Condition Report Sale Sale Date Location: Viewing: Removal: 1820-09/10/2018 10:00:00 - Medical Equipment Auction - PART 2 09-10-2018 10:00 Malmesbury, Wiltshire, UK Friday 5th October 12pm - 5pm, Monday

More information

Condition Report. Olympus CYF-4A Fiber Cystoscope SN

Condition Report. Olympus CYF-4A Fiber Cystoscope SN Condition Report Sale Sale Date Location: Viewing: Removal: 1825-10/12/2018 10:00:00 - Live Webcast General Medical Equipment and Endoscopy Auction - PART 1 10-12-2018 10:00 Malmesbury. Wiltshire, Uk Friday

More information

Condition Report /09/ :00 - Endoscopy and General Medical Equipment - PART :00

Condition Report /09/ :00 - Endoscopy and General Medical Equipment - PART :00 Condition Report Sale Sale Date Location: Viewing: Removal: 1717-11/09/2017 13:00 - Endoscopy and General Medical Equipment - PART 1 11-09-2017 13:00 Malmesbury, Wiltshire, UK Friday 8th September 12pm-5pm

More information

Condition Report /09/ :00 - Medical Equipment Auction :00

Condition Report /09/ :00 - Medical Equipment Auction :00 Condition Report Sale Sale Date Location: Viewing: Removal: 1617-13/09/2016 10:00 - Medical Equipment Auction 13-09-2016 10:00 Malmesbury, Wiltshire, UK Friday 9th September 12pm-5pm, Monday 12th September

More information

Professional Health Solutions

Professional Health Solutions Professional Health Solutions Product Catalogue 2017 2 Table of contents Patient Monitors 4-5 Central Monitoring System 6 ECG Simulator 6 ECG Devices 6-7 Pulse Oximeter Units 8 Electrosurgical Unit 8 ECG

More information

Sheath E-Line 8,5 Fr, With Obturator For 1 Urethrotome

Sheath E-Line 8,5 Fr, With Obturator For 1 Urethrotome ANNEXURE-A DEPARTMENT OF PAEDIATRICS OPTICAL INSTRUMENTS S.No. Name of the Items Specifications Qty. Neonatal Cystoscope Miniature Compact Cysto-Urethroscope 4.5/6.5 FR. With 0 Degree Angle Of View 2.4FR

More information

a. Arthroscopes Stryker, Storz, Dyonics many in stock - Call b. Arthroscopy Instruments many in stock, please inquire

a. Arthroscopes Stryker, Storz, Dyonics many in stock - Call b. Arthroscopy Instruments many in stock, please inquire I. Orthopedics / Arthroscopy a. Arthroscopes Stryker, Storz, Dyonics many in stock - Call b. Arthroscopy Instruments many in stock, please inquire c. Arthroscopy Systems Stryker, Storz, Dyonics Cameras,

More information

ACCESSORY GUIDE REV D

ACCESSORY GUIDE REV D ACCESSORY GUIDE REV D *989803171721* 989803171721 Model 865214 April 2011 Frequently Ordered Items Part Number Description Page QTY ECG Accessories 989803152291 Prep Gel 4 989803152321 Standard Quadtrode

More information

HLL Lifecare Ltd. Amendment No.1. Ref: (i) Tender Enquiry No.: HLL/PCD/PMSSY/AIIMS-II/27/18-19 dated

HLL Lifecare Ltd. Amendment No.1. Ref: (i) Tender Enquiry No.: HLL/PCD/PMSSY/AIIMS-II/27/18-19 dated Amendment No. Date: 27.04.208 Subject: Amendment no. to the Tender Enquiry Document Ref: (i) Tender Enquiry No.: HLL/PCD/PMSSY/AIIMS-II/27/8-9 dated 09.04.208 The pre bid meeting of the above referred

More information

FLORIDA LIFE SYSTEMS, INC. PH

FLORIDA LIFE SYSTEMS, INC. PH OTV-S7 INCLUDES PROCESSOR, AUTOCLAVABLE Camera Head with Coupler FLORIDA LIFE SYSTEMS, INC. PH 727.321-9554 FLORIDA LIFE SYSTEMS, INC 2632 NW 43 rd St. Ste# E-9 GAINESVILLE, FL 32606 PH. 727.321-9554 EMAIL

More information

Your Eye Inside. VIDEO BORESCOPES Made in USA. The next generation of fully-portable, articulating videoscopes!

Your Eye Inside. VIDEO BORESCOPES Made in USA. The next generation of fully-portable, articulating videoscopes! Hawkeye Video Borescopes The next generation of fully-portable, articulating videoscopes! Your Eye Inside VIDEO BORESCOPES Made in USA fast, portable, visual inspection anywhere! Bright, Crisp, Clear Images!

More information

Professional Health Solutions

Professional Health Solutions Professional Health Solutions Product Catalogue 2016 2 Table of contents - 5 Patient Monitors 4 Central Monitoring System 6 ECG Simulator 6 ECG Devices 6-7 Pulse Oximeter Units 8 - Electrosurgical Unit

More information

ipad SP2 Automatic External Defibrillator

ipad SP2 Automatic External Defibrillator ipad SP2 Automatic External Defibrillator www.ipad-aed.com #creatinglifesavers www.ipad-aed.com Key Features Compact. Robust. Lightweight. The ipad SP2 is designed for durability. It is drop tested from

More information

Rigel SIM Range Accessory List. Innovating Together

Rigel SIM Range Accessory List. Innovating Together Rigel SIM Range Accessory List Innovating Together Rigel SIM Range Accessory List SpO2 Interconnect Solutions (for use with SP-SIM and UNI-SIM only) Part No. Description Compatibility Image Specification

More information

Fiberoptic Bronchoscopy Redefined, Once Again

Fiberoptic Bronchoscopy Redefined, Once Again Fiberoptic Bronchoscopy Redefined, Once Again Fiberoptic bronchoscopy still has a lot to offer that s why we re introducing the all-new OES-60 bronchofiberscope lineup A new direction in the evolution

More information

Model: CAM430MV Wired Multi-View Camera with License Plate / Rear Surface Mount Installation Manual Features

Model: CAM430MV Wired Multi-View Camera with License Plate / Rear Surface Mount Installation Manual Features Model: CAM430MV Wired Multi-View Camera with License Plate / Rear Surface Mount Installation Manual Features Fully Adjustable, Multiple Viewing Angle Smart Camera. High Resolution, 1/2 CMOS Color Camera

More information

Vision of the Next Generation

Vision of the Next Generation VISERA VIDEO SYSTEM VISERA VIDEO SYSTEM Specifications, design and accessories are subject to change without any notice or obligation on the part of the manufacturer. Vision of the Next Generation Exceeding

More information

STEP 2: VITALSBRIDGE TO PATIENT MONITOR CONNECTION GUIDE VITALSBRIDGE AND 100

STEP 2: VITALSBRIDGE TO PATIENT MONITOR CONNECTION GUIDE VITALSBRIDGE AND 100 STEP 2: VITALSBRIDGE TO PATIENT MONITOR CONNECTION GUIDE VITALSBRIDGE 300 200 AND 100 Basic Steps: 1. Connect power to the VitalsBridge 2. Turn the VitalsBridge on 3. Connect the VitalsBridge to your patient

More information

LIFEPAK 15 Test Calibration Procedure ( TCP)

LIFEPAK 15 Test Calibration Procedure ( TCP) This section contains the Test and Calibration Procedures (TCP). Perform the procedures in this section as necessary after replacing device components or to correct out-of-specification conditions detected

More information

ENT /2018-E TELE PACK X LED. New Dimensions in LED Stroboscopy

ENT /2018-E TELE PACK X LED. New Dimensions in LED Stroboscopy ENT 134 6.2 06/2018-E TELE PACK X LED New Dimensions in LED Stroboscopy The TELE PACK X LED continues the tradition of the portable all-in-one systems from KARL STORZ. It can be used for a wide range of

More information

Amendment No. 02. Ref: (i) Tender No: HITES/PCD/AIIMS-BBSR/04/18-19 dated Section I Notice Inviting Tenders(NIT)

Amendment No. 02. Ref: (i) Tender No: HITES/PCD/AIIMS-BBSR/04/18-19 dated Section I Notice Inviting Tenders(NIT) Sub: Amendment. 02 Amendment.02 to the Tender Enquiry Document Date: 08/04/2019 Ref: (i) Tender : HITES/PCD/AIIMS-BBSR/04/18-19 dated 07.03.2019 1) For:- Section I tice Inviting Tenders(NIT) Sl RFx Equipment

More information

Original Manufacturer

Original Manufacturer MEDICAL ISSUE 2 Original Manufacturer Medical Accessories ECG/DEFIBRILLATOR LEADS SP02 SENSORS NIBP CUFFS ELECTRODES/PADS Supplying the Healthcare sector for over 30 years MANY ACCESSORIES ADDED Tel: +44

More information

BF-UC180F. Endoscopic Ultrasonography Setting a New Standard in Mediastinal Diagnostics.

BF-UC180F. Endoscopic Ultrasonography Setting a New Standard in Mediastinal Diagnostics. 9391 BF-UC180F Endoscopic Ultrasonography Setting a New Standard in Mediastinal Diagnostics. THE INNOVATIVE ENDOSCOPE WITH SUPERIOR ULTRASOUND IMAGING FOR EBUS-TBNA Compatible with Olympus universal endoscopic

More information

User Manual DUO BEAM/RG

User Manual DUO BEAM/RG User Manual DUO BEAM/RG Thank you for purchasing the DUO BEAM/RG Laser Show System. This manual is intended to help you to use the functions of the unit. It is suggested that you should refer to this instruction

More information

RAD system. C- arm. Price 337,500 SDG. Mobile C-arm: Model OPESCOPE Activo. 2 monitors. Easy to use. Quick c-arm positioning. Simple operation.

RAD system. C- arm. Price 337,500 SDG. Mobile C-arm: Model OPESCOPE Activo. 2 monitors. Easy to use. Quick c-arm positioning. Simple operation. RAD system SHIMADZU is one of the world's Japanese leading manufacturers of advanced imaging systems and equipment for use in medical diagnosis and treatment. NASIF Medical imported and distributed all

More information

OMM200 and OMM200T. Metallurgical Microscope

OMM200 and OMM200T. Metallurgical Microscope OMM200 and OMM200T Metallurgical Microscope Instruction Manual (Please read the manual carefully before using the microscope) Contents Safety ----------------------------------------------------------------------------

More information

Propaq LT Monitors. Propaq LT Base Model. Propaq LT with Wireless Option/ Legendary quality and durability Heart rate, 3-or 5-lead ECG, SpO 2

Propaq LT Monitors. Propaq LT Base Model. Propaq LT with Wireless Option/ Legendary quality and durability Heart rate, 3-or 5-lead ECG, SpO 2 Patient Monitors Propaq LT Monitors Monitor more patients in more places than ever before. Designed for bedside procedures ambulatory monitoring and intrahospital transport it is ideal for busy hospital

More information

Endoscopes of highest standards for ENT-specialists

Endoscopes of highest standards for ENT-specialists Endoscopes of highest standards for ENT-specialists Sinuscopes The fibre-optic of the sinuscopes enables at small dimensions a high contrast as well as high resoluted images for a perfect and patient-friendly

More information

MONITOR/DEFIBRILLATOR CONTROLS, CONNECTIONS AND INDICATORS

MONITOR/DEFIBRILLATOR CONTROLS, CONNECTIONS AND INDICATORS MONITOR/DEFIBRILLATOR CONTROLS, CONNECTIONS AND INDICATORS Adult Dose 100 120 70 170 50 200 30 20 15 1-10 CONTROLS, CONNECTIONS AND INDICATORS External Power SYNC Mark Event Lead Select Alarm Pause Event

More information

INSPECTION TOOL. Inspection Video Camera with Color LCD Monitor. EU Environmental Protection. Model: 8802LE,8803LE. Model: 8802LE,8803LE

INSPECTION TOOL. Inspection Video Camera with Color LCD Monitor. EU Environmental Protection. Model: 8802LE,8803LE. Model: 8802LE,8803LE INSPECTION TOOL Inspection Video Camera with Color LCD Monitor Model: 8802LE,8803LE EU Environmental Protection Waste electrical products should not be disposed of with household waste. Please recycle

More information

Catalogue POLYDIAGNOST Version: 2.7 With publication of this catalogue older versions loose their validation

Catalogue POLYDIAGNOST Version: 2.7 With publication of this catalogue older versions loose their validation 2015 Catalogue POLYDIAGNOST Version: 2.7 With publication of this catalogue older versions loose their validation POLYDIAGNOST Am Söldnermoos 17 85399 Hallbergmoos Germany Phone: +49 811 99873380 Fax:

More information

INTRODUCTION The Monitor, interchangeable modules and storage batteries are described below. Refer to the table below for specifications.

INTRODUCTION The Monitor, interchangeable modules and storage batteries are described below. Refer to the table below for specifications. PRODUCT DESCRIPTION INTRODUCTION The Monitor, interchangeable modules and storage batteries are described below. Refer to the table below for specifications. DINAMAP MPS Select Portable Monitor General

More information

Your Eye Inside VIDEO BORESCOPES. The next generation of fully-portable, articulating videoscopes!

Your Eye Inside VIDEO BORESCOPES. The next generation of fully-portable, articulating videoscopes! Hawkeye Video Borescopes The next generation of fully-portable, articulating videoscopes! Your Eye Inside Contika Aps Hindhøjen 82 8382 Hinnerup Tel: 8624 5066 mail@contika.dk VIDEO BORESCOPES Made in

More information

Equine Dental Scope VET /2017-E

Equine Dental Scope VET /2017-E Equine Dental Scope VET 40 2.1 11/2017-E Dental Endoscopy: See clearly and document all areas of the horse's mouth The use of an endoscope during equine dental exams, cleaning, floating, or extracting

More information

Resusci Anne Simulator

Resusci Anne Simulator EN Resusci Anne Simulator User Guide www.laerdal.com Intended Use The Resusci Anne Simulator is a realistic manikin designed to meet the learning objectives of basic healthcare, intermediate life support

More information

Ansur Index 2XL. Users Manual. Plug-In

Ansur Index 2XL. Users Manual. Plug-In Ansur Index 2XL Plug-In Users Manual April 2010, Rev. 1 2010 Fluke Corporation. All rights reserved. All product names are trademarks of their respective companies. Table of Contents Chapter Title Page

More information

Rigel Medical. Leaders in biomedical test solutions. Performance Analyzers. Vital Signs Simulators. Electrical Safety Analyzers

Rigel Medical. Leaders in biomedical test solutions. Performance Analyzers. Vital Signs Simulators. Electrical Safety Analyzers Innovating Together Rigel Medical Leaders in biomedical test solutions Performance Analyzers Vital Signs Simulators Electrical Safety Analyzers Asset Management Software Accessories Data traceability Test

More information

LASER SLIT LAMP. Optimized for Retina

LASER SLIT LAMP. Optimized for Retina VERSATILE GREEN LASER Full-featured, portable green laser for the clinic and operating room. LASER SLIT LAMP Magnification 5x, 8x, 12.5x, 20x, 31x with 12.5x eyepieces (±5 D compensation range) Field of

More information

Brighten The World With

Brighten The World With PRODUCT LIST Brighten The World With JW Medical Technology JW Values Respect for Life and the Pioneering Spirit JW Medical aims to lead advancement in healthcare services based on its founding principles

More information

HDAF800 HD 1080p Digital Microscope USB drive for Image Capture

HDAF800 HD 1080p Digital Microscope USB drive for Image Capture HDAF800 HD 1080p Digital Microscope USB drive for Image Capture HDAF800-US Auto-Focus HD Camera System 1080p including Universal Stand with 15" Vertical Pole and integrated LED lighting and controls panels.

More information

700TSU INSTALLATION MANUAL

700TSU INSTALLATION MANUAL M 700TSU INSTALLATION MANUAL 2 Table of Contents Features...03 Specifications...04 Quick-Start...05 Remote Control...07 Hardware Installation...10 Software Installation...14 Touch Screen Driver Installation

More information

LIFEPAK CR PLUS/EXPRESS Defibrillator TABLE OF CONTENTS

LIFEPAK CR PLUS/EXPRESS Defibrillator TABLE OF CONTENTS Section Contents Performance Inspection Procedure The (PIP) is a set of manual and computerassisted test procedures used by authorized Physio-Control service representatives. It will be used as an operational

More information

Dräger UCF 9000 NFPA Certified Thermal Imaging Camera

Dräger UCF 9000 NFPA Certified Thermal Imaging Camera Dräger UCF 9000 NFPA Certified Thermal Imaging Camera When you enter an unknown environment, you need all the information you can get as quickly and easily as possible. The Dräger UCF 9000 is an intrinsically

More information

Contents. - i - Ver.:2

Contents. - i - Ver.:2 Contents 1 Accessories of D-Point 2... 2 2 Connecting Projector to PC... 4 3 Pen Action... 4 4 Driver Installation... 5 5 Configuration Setting... 8 6 D-Point 2 Pull-up Menu... 12 7 DT02 Multi-touch Interactive

More information

Cardiostart. Biphasic Defibrillator Monitor

Cardiostart. Biphasic Defibrillator Monitor Cardiostart Biphasic Defibrillator Monitor Standard Accessories Carrying Case Rechargeable lithium ion battery Set of accessories Other accessories upon request Internal Pads Adult / Pediatric / Neonatal

More information

High Definition VideoScope

High Definition VideoScope User Manual High Definition VideoScope Model HDV600 Additional User Manual Translations available at www.extech.com Introduction Congratulations on your purchase of this Extech HDV600 series Video Borescope.

More information

Removal and Installation8

Removal and Installation8 8 Screw Types 8-4 Top Cover Assembly 8-5 Left Hand Cover 8-6 Right Hand Cover 8-10 Front Panel Assembly 8-14 Left Rear Cover 8-15 Right Rear Cover 8-16 Extension Cover (60" Model only) 8-17 Media Lever

More information

Operating Microscope OM-18. A i m i n g a t n e w l e v e l s i n q u a l i t y

Operating Microscope OM-18. A i m i n g a t n e w l e v e l s i n q u a l i t y Operating Microscope OM-18 A i m i n g a t n e w l e v e l s i n q u a l i t y Operating Microscope OM-18 Compact Microscope Diverse illumination optics Protection against phototoxicity Apochromatic objective

More information

Mindray North America. Patient Monitoring FAQ s

Mindray North America. Patient Monitoring FAQ s Mindray North America Patient Monitoring FAQ s Product Passport V 1) Q.) Can the Passport V interface to an EMR system? 2) In most cases, yes. The Passport V features two serial ports, either of which

More information

Insignia - Icon SPARE PARTS CATALOG LASER MARKING SYSTEMS

Insignia - Icon SPARE PARTS CATALOG LASER MARKING SYSTEMS Insignia - Icon LASER MARKING SYSTEMS 1998-2005 To Order Parts Contact: 1(866) 612-8619 / Fax: (407) 926-3551 or Visit Our Website: TABLE OF CONTENTS Insignia - Icon DESCRIPTION PAGE Insignia Control Cabinet

More information

MOBILE SAFETY DVR1543K. CLIP ON REARVIEW MIRROR KIT with 4.3-INCH LCD MONITOR FRONT & REAR CAR CAMCORDER with DUAL MOUNTING REVERSING CAMERA

MOBILE SAFETY DVR1543K. CLIP ON REARVIEW MIRROR KIT with 4.3-INCH LCD MONITOR FRONT & REAR CAR CAMCORDER with DUAL MOUNTING REVERSING CAMERA MOBILE SAFETY DVR1543K REARVIEW MIRROR CAR DRIVING RECORDER KIT CLIP ON REARVIEW MIRROR KIT with 4.3-INCH LCD MONITOR FRONT & REAR CAR CAMCORDER with DUAL MOUNTING REVERSING CAMERA 3.0 MEGA PIXEL CAMERA

More information

Neonatal Care System. Infant Incubator Infant Warmer Phototherapy

Neonatal Care System. Infant Incubator Infant Warmer Phototherapy Neonatal Care System Infant Incubator Infant Warmer BT-500 Infant Incubator Environment designed for premature baby Double Wall and air curtain maintain constant temperature control in the hood and help

More information

PMI Borescope Lizard 100 Series User Guide

PMI Borescope Lizard 100 Series User Guide PMI Borescope Lizard 100 Series User Guide Thank you very much for purchasing Lizard 100 borescope. Be sure to read this Instruction manual before using, for operating it safely and correctly. Please keep

More information

April 30, Dear Health Care Professional:

April 30, Dear Health Care Professional: April 30, 2010 Re: Compatibility of Olympus Small Diameter Flexible Endoscopes, Camera Heads and Accessories with the STERRAD NX Sterilizer: Technical Information for Olympus Customers in the United States

More information

Unpacking and Installing the Flora 2512 UV Printer. Steps 1: Unscrew the 10mm bolts holding the top. Then remove the top and put in a safe place.

Unpacking and Installing the Flora 2512 UV Printer. Steps 1: Unscrew the 10mm bolts holding the top. Then remove the top and put in a safe place. Unpacking and Installing the Flora 2512 UV Printer Steps 1: Unscrew the 10mm bolts holding the top. Then remove the top and put in a safe place. Step 2: Unscrew 10mm bolts holding the end panels. On the

More information

A TOPCON EXAM SOLUTION. Topcon Slit Lamp Series.» Quality» Precision» Durability

A TOPCON EXAM SOLUTION. Topcon Slit Lamp Series.» Quality» Precision» Durability A TOPCON EXAM SOLUTION Topcon Slit Lamp Series» Quality» Precision» Durability Quality. Precision. Durability. The Topcon family of slit lamps include a wide variety of models including traditional clinical

More information

Table of Contents. Chapter 1. Safety Precautions Notice Chapter 2. Components and accessories Chapter 3. Camera components...

Table of Contents. Chapter 1. Safety Precautions Notice Chapter 2. Components and accessories Chapter 3. Camera components... P. 770.270.1394 F. 770.270.2389 865 Marathon Parkway Lawrenceville GA 30046 P. 770.270.1394 F. 770.270.2389 865 Marathon Parkway Lawrenceville GA 30046 Table of Contents Chapter 1. Safety Precautions Notice...

More information

Hardware and Components: Philips Monitors in Critical Care

Hardware and Components: Philips Monitors in Critical Care Hardware and Components: Philips Monitors in Critical Care Intellivue MX 800 (the monitor): This is the new bedside monitor. It is a touch screen. Touch will work even when double gloved. The monitor WILL

More information

Non-Contact Depth Measuring Microscope System DH2/IMH

Non-Contact Depth Measuring Microscope System DH2/IMH Non-Contact Depth Measuring Microscope System DH2/IMH Specially designed focus indicator (Target Mark) facilitates focusing operation greatly. Highly accurate and repeatable measurement is possible. No

More information

Resusci Anne Advanced SkillTrainer

Resusci Anne Advanced SkillTrainer EN Resusci Anne Advanced SkillTrainer User Guide www.laerdal.com Intended Use The Resusci Anne Advanced SkillTrainer is designed to meet the core learning objectives of intermediate to advanced healthcare.

More information

HIPP Endoskop Service GmbH >> your requirements are our aims. HIPP Video Borescope Series VB. Technical Product Information

HIPP Endoskop Service GmbH >> your requirements are our aims. HIPP Video Borescope Series VB. Technical Product Information HIPP Endoskop Service GmbH >> your requirements are our aims. HIPP Video Borescope Series VB Technical Product Information HIPP Borescopes >> for industrial application. Our vision giving the gift of time

More information

Global Service. Product Catalog Cardiac Assist

Global Service. Product Catalog Cardiac Assist Global Service Product Catalog Cardiac Assist Global Service Product Catalog Cardiac Assist 1 Intra-Aortic Balloon Pump MCare Service Plans In addition to the standard warranty provided with your IABP,

More information

Borescopes. Endoscopy with highest image quality

Borescopes. Endoscopy with highest image quality Borescopes Endoscopy with highest image quality Rigid endoscopes Unequalled image quality for more than 70 years Borescopes Dr. Karl Storz started to produce ENT instruments in 1945. He wanted to develop

More information

INSPECTION TOOL. Wireless Inspection Camera with Recordable Monitor. EU Environmental Protection. Model: 8802AL, 8803AL. Model: 8802AL, 8803AL

INSPECTION TOOL. Wireless Inspection Camera with Recordable Monitor. EU Environmental Protection. Model: 8802AL, 8803AL. Model: 8802AL, 8803AL TM TM INSPECTION TOOL Wireless Inspection Camera with Recordable Monitor Model: 8802AL, 8803AL EU Environmental Protection Waste electrical products should not be disposed of with household waste. Please

More information

TRANQUILITY VS VERSATILITY IN VITAL SIGNS A M E R I C A S TRANQUILITY VS A M E R I C A S

TRANQUILITY VS VERSATILITY IN VITAL SIGNS A M E R I C A S TRANQUILITY VS A M E R I C A S VERSATILITY IN VITAL SIGNS PORTABLE weighs less than 6lbs TOUCHSCREEN easy and intuitive to use MOBILE backup battery powered The Tranquility VS is a new and intuitive approach to patient vital signs measurement.

More information

VX85 Slit Lamps. Precision at high level. Electric height adjustment VX85

VX85 Slit Lamps. Precision at high level. Electric height adjustment VX85 Slit Lamps VX85 Slit Lamps Precision at high level Converging 6-3 magnifications Parallel 6-3 magnifications REF. 8485-0001-03 REF. 8485-0002-03 Converging 6-5 magnifications Parallel 6-5 magnifications

More information

is your system The System Unique features to meet the individual needs of surgical specialties. The System Approach to Electrosurgical Excellence

is your system The System Unique features to meet the individual needs of surgical specialties. The System Approach to Electrosurgical Excellence I n t r o d u c i n g a r e v o l u t i o n a r y a p p r o a c h t o e l e c t r o s u r g e r y The System is your system Generators Pads The System Approach to Electrosurgical Excellence Plume Mgmt.

More information

FengMi Wemax One Laser Projection TV

FengMi Wemax One Laser Projection TV FengMi Wemax One Laser Projection TV User`s Manual About electrical ground Transportation Use this device only with a compulsory grounding condition. It is recommended that you use the original packaging

More information

Contents LARYNGOSCOPES. HD Laryngoscope Rigid Laryngoscopes...ENR-105 ENR-110. Telescopes for Larynx Surgery...ENR-125 SINUSCOPES

Contents LARYNGOSCOPES. HD Laryngoscope Rigid Laryngoscopes...ENR-105 ENR-110. Telescopes for Larynx Surgery...ENR-125 SINUSCOPES Contents LARYNGOSCOPES HD Laryngoscope Rigid Laryngoscopes...ENR-105 ENR-110 Telescopes for Larynx Surgery...ENR-125 SINUSCOPES HD Sinuscopes 4 mm...enr-206 TrueView II 2.7 mm Sinuscopes...ENR-207 Mini-TrueView

More information

AOC MONITOR USER`S GUIDE V22+ SAFETY INTRODUCTION.2 SETUP.4 ADJUSTING...7 DRIVER INSTALLATION GUIDE.. 10 PRODUCT INFORMATION.16 TROUBLESHOOT...

AOC MONITOR USER`S GUIDE V22+ SAFETY INTRODUCTION.2 SETUP.4 ADJUSTING...7 DRIVER INSTALLATION GUIDE.. 10 PRODUCT INFORMATION.16 TROUBLESHOOT... AOC MONITOR USER`S GUIDE V22+ SAFETY INTRODUCTION.2 SETUP.4 ADJUSTING......7 DRIVER INSTALLATION GUIDE.. 10 PRODUCT INFORMATION.16 TROUBLESHOOT......17 Page١ SAFETY INTRODUCTION The following subsections

More information

User Manual. Trinocular Stereo Microscope

User Manual. Trinocular Stereo Microscope User Manual Trinocular Stereo Microscope Model V434 XV434 Series MicroscopeNet.com Table of Contents i. Caution.. 1 ii. Care and Maintenance... 2 1. Component Illustration... 3 2. Installation 4 3. Operation....6

More information

Rigid Endoscopy. Jenny Rayne Buyer

Rigid Endoscopy. Jenny Rayne Buyer Jenny Rayne Buyer endodecon@supplychain.nhs.uk Specification Arthrex Ltd B. Braun Conmed Karl Storz Endoscopy Arthroscopy Scopes Available in lengths: 1, Available in lengths: 58mm, 72mm, 140mm, 150mm,

More information

User's Guide. Video Borescope. Models BR200 and BR250

User's Guide. Video Borescope. Models BR200 and BR250 User's Guide Video Borescope Models BR200 and BR250 Introduction Congratulations on your purchase of this Extech BR200 (17mm camera head) or BR250 (9mm camera head) Video Borescope. This instrument was

More information

SPECIFICATION FOR BLACK BODY CALIBRATION SOURCE

SPECIFICATION FOR BLACK BODY CALIBRATION SOURCE SPECIFICATION FOR BLACK BODY CALIBRATION SOURCE Source to calibrate Infrared thermometer in the range of 50 C to 1000 C with suitable internal sensor. PID controller and digital display for displaying

More information

Thin, compact and lightweight just 20mm thin High-Speed Start-Up in approx. 0.9 sec 3x optical flat zoom mm Zoom 3.2 Megapixel Stylish design

Thin, compact and lightweight just 20mm thin High-Speed Start-Up in approx. 0.9 sec 3x optical flat zoom mm Zoom 3.2 Megapixel Stylish design Thin, compact and lightweight just 20mm thin High-Speed Start-Up in approx. 0.9 sec 3x optical flat zoom 37 111mm Zoom 3.2 Megapixel Stylish design with new colour variations Champaign Silver - Sweet Red

More information

AEROTRAK PORTABLE AIRBORNE PARTICLE COUNTER MODEL 9310/9350/9510/9550/9500 QUICK START GUIDE

AEROTRAK PORTABLE AIRBORNE PARTICLE COUNTER MODEL 9310/9350/9510/9550/9500 QUICK START GUIDE AEROTRAK PORTABLE AIRBORNE PARTICLE COUNTER MODEL 9310/9350/9510/9550/9500 QUICK START GUIDE Thank you for purchasing a TSI AeroTrak Portable Airborne Particle Counter (particle counter). This guide will

More information

Amendment No: 2 Date: 13/09/2013

Amendment No: 2 Date: 13/09/2013 Amendment No: 2 Date: 13/09/2013 Ref: Tender Enquiry : HLL/PCD/PMSSY/-II/01/13-14 Dated 17.08.2013 SECTION I NOTICE INVITING TENDERS (NIT) Page 1 of 7 Qty PER EMD (Rs.) 1 CT Scan - 64 ice 1 6 7,200,000

More information

Propaq Vital Signs Monitors

Propaq Vital Signs Monitors Propaq Vital Signs Monitors Propaq CS and Encore monitors are shipped complete with adult, pediatric and neonatal monitoring capability. The Base Monitor includes ECG, NIBP, Temperature, Impedance Pneumography

More information

Product Specifications

Product Specifications Product Specifications Physical Defibrillator Model HeartStart MRx (M3536A) Dimensions Without external paddles: 12.4 in. (W) x 7.7 in. (D) x 11.7 in. (H) (313 mm x 195 mm x 295 mm). With external paddles:

More information

User Manual. SSA-20 - CO 2 Incubator Analyser

User Manual. SSA-20 - CO 2 Incubator Analyser User Manual SSA-20 - CO 2 Incubator Analyser 1 Introduction The SSA-20 is the new handheld CO 2 analyser specially designed by Samson Scientific to measure, verify and validate the CO 2 levels on CO 2

More information

VX70. Slit Lamps. Stereo Microscope

VX70. Slit Lamps. Stereo Microscope Slit Lamps VX70 Stereo Microscope Converging 6-5 magnifications REF. 8470-0001-05 Converging 6 - magnifications REF. 8470-0001-0 Converging 6-2 magnifications REF. 8470-0001-02 With its modern optical

More information

V-MUX CONNECTOR and ACCESSORY SPEC

V-MUX CONNECTOR and ACCESSORY SPEC P V-MUX V-MUXP CONNECTOR AND ACCESSORY REFERENCE SPECIFICATION August 2007 8/2/07 Page 1 of 26 V-MUX nodes for all multiplex applications: Hercules #6000-0000-03 (16) wired switch Inputs (3) wired 0-5V

More information

British Medical Auctions

British Medical Auctions British Medical Auctions BMA - UK - December Specialist Medical Equipment Auctions Two Day Specialist Medical Equipment Auction - Thursday 1st December and Friday 2nd December Unit 1 Springlakes Industrial

More information

Tesla M3 MRI Patient Monitor

Tesla M3 MRI Patient Monitor Tesla M3 MRI Patient Monitor Tesla M3 MIPM Monitoring of the 3 rd Generation! TeslaM3 Configuration Basic configuration 3 Parameters: ECG, SpO 2, NIBP All remaining parameters are optional and can be combined

More information

5.6" Multi-function Monitor

5.6 Multi-function Monitor 5.6" Multi-function Monitor User s Manual Please read this Manual carefully before use of this product, and keep it handy for future reference. I. Packing List.. 2 II. Product Appearance... 3-5 III. Product

More information

FastCam Outdoor Speed Dome Camera

FastCam Outdoor Speed Dome Camera FastCam Outdoor Speed Dome Camera CC-9760 & CC-9760-I USER INSTRUCTION MANUAL Version: V1.2 Doc No.: 20051114001 1 A BOUT THIS GUIDE Conventions used in this guide To make sure that you perform certain

More information

USER GUIDE. Waterproof Borescope. Models BR300 and BR350

USER GUIDE. Waterproof Borescope. Models BR300 and BR350 USER GUIDE Waterproof Borescope Models BR300 and BR350 Introduction Thank you for selecting the Extech Instruments Model BR300/BR350 Waterproof Borescope. The Waterproof Borescope can be fully immersed

More information

User Guide. Video Borescope. Models BR200 and BR250

User Guide. Video Borescope. Models BR200 and BR250 User Guide Video Borescope Models BR200 and BR250 Introduction Congratulations on your purchase of this Extech BR200 (17mm camera head) or BR250 (9mm camera head) Video Borescope. This instrument was designed

More information

Symbols Glossary Rev. 1 1 / 16

Symbols Glossary Rev. 1 1 / 16 5.4.3 Consult instructions for use Indicates the need for the user to consult the instructions for use. 1641 electronic Table D.1 11 IEC 60601-2-18 electronic equipment Part 2-18: Particular the performance

More information

MONITOR/DEFIBRILLATOR CONTROLS, CONNECTIONS AND INDICATORS

MONITOR/DEFIBRILLATOR CONTROLS, CONNECTIONS AND INDICATORS MONITOR/DEFIBRILLATOR CONTROLS, CONNECTIONS AND INDICATORS 1-10 Adult Dose CONTROLS, CONNECTIONS AND INDICATORS External Power SYNC Mark Event Lead Select Alarm Pause Event Summary Soft Keys Soft Keys

More information

Aspera R7. User Manual

Aspera R7. User Manual 1 Aspera R7 User Manual Contents Safety Information... 3 Appearance and Key Function... 5 Introduction... 6 Call Functions... 7 Notifications Bar... 8 Contacts... 9 Messaging... 9 Bluetooth and Wi-Fi...

More information

Standard Operating Procedure For The Kaye Validator 2000 Thermal Mapping System

Standard Operating Procedure For The Kaye Validator 2000 Thermal Mapping System Standard Operating For The Kaye Validator 2000 Thermal Mapping System SOP No: V01/SOP/505/15 Version No: 01 No of Copies issued: 01 Copy Number: 01 PharmaTherm Limited Circulation: 1. Mr Andrew Varley,

More information

EV3.0 CAMERA CONTROL UNIT

EV3.0 CAMERA CONTROL UNIT EV3.0 CAMERA CONTROL UNIT Article Code PV630 Universal camera platform accepts 2D and 3D camera heads (for further information about the 2D Camera Heads please visit the APP/ Chapter 2D Technology/ Key

More information

Rigid endoscopes. Endoscopy with the highest image quality

Rigid endoscopes. Endoscopy with the highest image quality Rigid endoscopes Endoscopy with the highest image quality Rigid endoscopes Robust, reliable, universally usable Unsurpassed image quality thanks to the patented Hopkins rod lens system The KARL STORZ NDTec

More information

LED Accu Penta 9x12W RGBWAU

LED Accu Penta 9x12W RGBWAU Manual LED Accu Penta 9x12W RGBWAU Table of contents 1. Safety instructions... 3 1.1. FOR SAFE AND EFFICIENT OPERATION... 3 1.2. Additional Information for safety... 4 2. Introduction... 5 2.1. Statement...

More information

MONITOR VITAL SIGNS W/SPO²,W/CAPNO TOC

MONITOR VITAL SIGNS W/SPO²,W/CAPNO TOC MOITOR VITAL SIGS W/SPO²,W/CAPO TOC WELCH ALLY MODEL#: PROPAQ 206EL MOITOR W/SPO ² AD CAPOGRAPHY (Side stream, mainstream or dual) Manufacturer s PHOE: (503) 530-7500 FAX: (503) 530-4910 Website:http://www.welchallyn.com

More information

User Manual. Trinocular Stereo Microscope

User Manual. Trinocular Stereo Microscope User Manual Trinocular Stereo Microscope Model V436 XV436 Series MicroscopeNet.com Table of Contents i. Caution.. 1 ii. Care and Maintenance... 1 1. Component Illustration... 2 2. Installation 3 3. Operation....4

More information

QUICK START GUIDE LENS CHANGING GUIDE

QUICK START GUIDE LENS CHANGING GUIDE User Guide QUICK START GUIDE LENS CHANGING GUIDE GoVision is a brand of action camera sunglasses that allows users to capture their life-seeking adventures in high definition video/photography. High definition

More information

Linkam Scientific Instruments

Linkam Scientific Instruments THMS350V Vacuum System The THMS350V stage enables the user to create low pressure environment during complex heating and cooling profiles. Pressure is measured directly on the sample chamber and displayed

More information

The perfect combination

The perfect combination The perfect combination USB2 camera for diagnosis aid Ubicam USB cable 2 programmable buttons - White Balance - Freeze frames - Anti moire C-mount coupler Focus ring Scope holder uses 19 times less energy*

More information