OMRON PROGRAMMABLE CONTROLLER. Input terminals TIMER ADJUSTMENT
|
|
- Buck Hart
- 6 years ago
- Views:
Transcription
1 PLC004 21/01/04 DISPLAY UNIT MANUAL 1 OMRON PROGRAMMABLE CONTROLLER Input terminals Input indication LED s Programming port OMRON SYSMAC CPM2A Expansion connector Potentiometers located behind peripheral port cover. Output terminals Output indication LED s TIMER ADJUSTMENT The programmable controller is equipped with two potentiometers located under the peripheral port cover on the front of the unit. Their function is as follows: Pot. 0 - Pot. 1 - Door close timer. The range is from 2 to 26 seconds. Journey timer. The range is from 20 to 45 seconds. If either of the potentiometers are adjusted the display unit will automatically show the timer value, after a short time the status display will automatically resume.
2 PLC004 21/01/04 DISPLAY UNIT MANUAL 2 CONTROLLER SETUP Status display F1 View Fault Log Homing set to floor nn Clear Fault Log Homing delay nn minutes Display Counters Fire return set to floor nn F6 Controller Setup Doors: enable / disable Lift at floor nn Send to floor nn
3 PLC004 21/01/04 DISPLAY UNIT MANUAL 3 CONTROLLER SETUP From the status display press key F1 to enter the menu. Use keys and to scroll to Controller Setup. Press key F6 to select Controller Setup. Use keys and to scroll to the required parameter. To adjust the value press key F2, the green LED will light indicating that adjustment is now possible. Use keys and to change the value. Pressing key F6 will store the new value, the green LED will extinguish. Pressing key will leave the existing value unchanged, the green LED will extinguish. Pressing key when the green LED is off will revert back to the status display. Notes: The homing floor can be set to any floor, if homing is not required set the homing floor to 0. The homing time can be set from 1 to 15 minutes. The fire return floor can be set to any floor. Hydraulic controllers will return to the lowest level after 15 minutes of inactivity, this feature cannot be adjusted or disabled. Doors: enable / disable Setting this parameter will prevent the doors opening when the lift stops, it can be used when testing and commissioning the installation. If the doors are enabled, navigate to this screen and press key F6 to disable the doors. To re-enable the doors, navigate to this screen and press key F6 again. The state of this function will not change with re-initiation of the supply. Send to floor nn This function can be used to input car calls to the controller by setting a destination floor number. The adjustment procedure is described above. Adjustment will not be possible if the controller is out of service or unable to accept a call for any reason.
4 PLC004 21/01/04 DISPLAY UNIT MANUAL 4 VIEWING THE FAULT LOG From the status display press key F1 to enter the menu. Use keys and to scroll to View Fault Log. Press key F6 to select View Fault Log. The most recent fault is displayed. Use key F2 to toggle between the fault description and the fault floor with date. Pressing key at any time will revert back to the status display. Status display F1 View Fault Log F6 Most recent fault F2 at floor nn Date dd/mm/yy Clear Fault Log Display Counters Oldest fault F2 at floor nn Date dd/mm/yy Controller Setup Notes: The fault log will store a maximum of 50 faults. When a fault occurs it is automatically displayed and the red LED is illuminated, after a short time the status display is resumed but the red LED will remain illuminated until the fault log is manually viewed. In the case of a severe fault the red LED will flash and the fault will remain displayed until the processor is reset by re-initiation of the supply by a qualified engineer.
5 PLC004 21/01/04 DISPLAY UNIT MANUAL 5 FAULT CONDITIONS Car gate failed when stationary The car gate circuit did not energise when the doors fully closed. The controller will re-open and close the doors until the car gate circuit energises, this will be attempted a further 10 times before parking the doors open. This is not a severe fault but is indicated with a call accept output flashing twice followed by a three second pause, a car call must be registered and the doors must close correctly to reset this fault. Car gate failed when travelling The car gate circuit was interrupted when the lift was travelling causing a crash stop. If the car gate circuit becomes energised within 60 seconds the controller will attempt to complete the journey. Car overloaded The car overloaded switch was operated. This is only logged once at each floor. Communications failure duplex only The data communication link with the other controller was lost, this fault is also logged if the other controller is switched off. Door close protection The doors failed to fully close within 10 seconds. The controller will re-open and attempt to close the doors a further 10 times before parking the doors open. This is not a severe fault but is indicated with a call accept output flashing twice followed by a three second pause, a car call must be registered and the doors must close correctly to reset this fault. Door open protection The doors failed to fully open within 10 seconds. The controller will park the doors closed until the lift has moved to a different floor where another attempt is made to open the doors. This is not a severe fault but is indicated with a call accept output flashing twice followed by a three second pause, the lift must travel to reset this fault. Down drive failure While travelling down the controller failed to receive a stepping signal before the journey timer elapsed. The journey timer can be adjusted using POT 1 located on the front of the processor. This is a severe fault indicated with a call accept output flashing five times followed by a three second pause, the lift will stop and will not accept calls until the processor has been reset by re-initiation of supply. Floor zone proximity fail While travelling the controller has not received a proximity monitor signal indicating that all floor zone proximities are de-energised when the lift is away from floor level. This is a severe fault indicated with a call accept output flashing three times followed by a three second pause, the lift will stop at the next registered call and will not accept further calls until the processor has been reset by re-initiation of supply.
6 PLC004 21/01/04 DISPLAY UNIT MANUAL 6 FAULT CONDITIONS Gate lock failed when stationary The landing gate lock circuit did not energise when the doors fully closed. The controller will re-open and close the doors until the gate lock circuit energises, this will be attempted a further 10 times before parking the doors open. This is not a severe fault but is indicated with a call accept output flashing twice followed by a three second pause, a car call must be registered and the doors must close correctly to reset this fault. Gate lock failed when travelling The landing gate lock circuit was interrupted when the lift was travelling causing a crash stop. If the gate lock circuit becomes energised within 60 seconds the controller will attempt to complete the journey. Incorrect direction traction only The lift did not travel in the expected direction or the level up and level down proximities are reversed. This is a severe fault indicated with a call accept output flashing four times followed by a three second pause, the lift will stop and will not accept calls until the processor has been reset by re-initiation of supply. Internal battery voltage low The processors internal memory backup battery voltage is too low and should be replaced immediately to retain setup data. The battery is located under the front cover of the processor. Note that the power must first be switched off and the new battery connected within 5 minutes of disconnecting the old battery. Level down proximity failed The controller did not receive a level down proximity signal at floor level. Level up proximity failed The controller did not receive a level up proximity signal at floor level. Low speed protection trip After slowing the lift failed to reach floor level within 15 seconds. The call at that floor is cancelled and the controller will answer any other calls present. Re-level protection trip hydraulic only After initiating a re-level the lift failed to reach floor level within 12 seconds. This is a severe fault indicated with a call accept output flashing four times followed by a three second pause, the lift will return to the lowest level and will not accept calls until the processor has been reset by re-initiation of supply. Re-level zone failure hydraulic only The re-level zone was not energised when the controller attempted to re-level. This is a severe fault indicated with a call accept output flashing four times followed by a three second pause, the lift will return to the lowest level and will not accept calls until the processor has been reset by re-initiation of supply.
7 PLC004 21/01/04 DISPLAY UNIT MANUAL 7 FAULT CONDITIONS Repetitive safe edge use The safety edge has been operated whilst the doors are closing, forcing a re-open, in excess of 10 times at the same floor. The doors will park open until a car call is registered and the lift travels to a different floor. This is not a severe fault but is indicated with a call accept output flashing twice followed by a three second pause. Safety circuit failure The safety circuit has been interrupted, note that the handwinding switch is also monitored as part of the safety circuit. If the safety circuit is re-energised the controller will initiate a reset run when a call is registered and return to normal operation. Selector out of step The processor received a terminal floor reset signal that did not correspond to the selector position. It is important that the stepping signals occur slightly before the reset signals. Note that the floor position stored for this fault will be either the top or bottom floor and will not necessarily indicate where the stepping proximity has failed. Starting failure After energising a direction output the processor has failed to receive feedback via the pump / drive contactors to the travelling input. Step proximity failure The lift has completed a journey between terminal floors without receiving a stepping signal. Note that the floor position stored for this fault will be the bottom floor and does not necessarily indicate where the failure occurred. This is a severe fault indicated with a call accept output flashing three times followed by a three second pause, the lift will stop at a terminal floor and will not accept further calls until the processor has been reset by re-initiation of supply. Simultaneous level and step While travelling the controller has received a stepping signal and a levelling signal simultaneously. This is a severe fault indicated with a call accept output flashing three times followed by a three second pause, the lift will stop at the next registered call and will not accept further calls until the processor has been reset by reinitiation of supply. Thermistors tripped The thermistors have tripped indicating possible motor overheating. The lift will stop at the next registered call and will not accept further calls until the motor has cooled sufficiently, hydraulic controllers will return to the lowest level during this cooling period. This is not a severe fault but is indicated with a call accept output flashing once every three seconds.
8 PLC004 21/01/04 DISPLAY UNIT MANUAL 8 FAULT CONDITIONS Top OR bottom reset failure Both terminal floor resets have energised simultaneously, the controller will accept calls but not attempt to travel when in this state. Note that the floor position stored for this fault will be the bottom floor and does not necessarily indicate which reset is faulty. Up drive failure While travelling up the controller failed to receive a stepping signal before the journey timer elapsed. The journey timer can be adjusted using POT 1 located on the front of the processor. This is a severe fault indicated with a call accept output flashing five times followed by a three second pause, the lift will stop and will not accept calls until the processor has been reset by re-initiation of supply. Hydraulic controllers will also return to the lowest level.
9 PLC004 21/01/04 DISPLAY UNIT MANUAL 9 Warning: CLEARING THE FAULT LOG The following procedure describes how to erase all the faults stored in the log, this action is irreversible. From the status display press key F1 to enter the menu. Use keys and to scroll to Clear Fault Log. Press key F6 to select Clear Fault Log. Pressing key F1 will erase the fault log and a confirmation message will appear for a short time. Pressing key F2 will abort the procedure. The status display will be automatically resumed. Status display F1 View Fault Log F2 Clear Fault Log F6 Erase ALL faults F1=YES F2=NO F1 Display Counters All faults erased Controller Setup
10 PLC004 21/01/04 DISPLAY UNIT MANUAL 10 VIEWING THE EVENT COUNTERS From the status display press key F1 to enter the menu. Use keys and to scroll to Display Counters. Press key F6 to select Display Counters. Use keys and to scroll through the counters. Press key to return to the status display. Status display F1 View Fault Log Journey counter nnnnnnnn Clear Fault Log Door operations nnnnnnnn Display Counters F6 Power failures nnnn Controller Setup Re-level counter nnnnnnnn Notes: The re-level counter is only applicable to hydraulic controllers. The event counters cannot be reset.
Gladiator Lift Services Ltd OPTIO MRL Controller Specification
Gladiator Lift Services Ltd OPTIO MRL Controller Specification 1 Control System Specification General Requirements Control Cabinet A new MRL control panel shall be provided being of the enclosed steel
More informationStandard Instructions Special Instructions High-Speed Instructions SIMATIC S7-200 Programmable Controller System Manual
Programming A PLC STEP 7-Micro/WIN32 is the program software used with the S7-2 PLC to create the PLC operating program. STEP 7 consists of a number of instructions that must be arranged in a logical order
More informationAn OR Operation. Or (O) Function I0.4 Q0.1 I0.5 I0.5 I0.4 Q0.1. Input 3. Input 4. Output 2
An OR Operation In this example an OR operation is used in network. It can be seen that if either input I0.2 (input 3) or (O in the statement list) input I0.3 (input 4), or both are true, then output Q0.
More informationSafety module SM A3
Kollmorgen Steuerungstechnik GmbH Kollmorgen Lift Controls Ltd. Broichstraße 32 Unit 2, The Office Village Cologne, Germany 51109 Chester Business Park Telephone +49 (0) 221 89 85 0 Chester, Cheshire,
More informationControl. Part B, Section 2. This section covers the following unit configurations. 3400V 3500V Voltage 1, 2, 3 Pump Piston (D, E, F, G)
Part B, Section 2 Model This section covers the following unit configurations. 3100V 3400V 3500V Voltage 1, 2, 3 Pump Piston (D, E, F, G) Manifold 4-Port (A) 6-Port (B or C) 2-Port (S or T) Vista Temperature
More informationInstructions. Modbus RTU Card (WSIQ-COM-MB)
Instructions (WSIQ-COM-MB) Contents 1 Warnings... 2 2 Important User Information... 2 3 Installation... 2 4 Operation... 3 5... 4 6 Specifications... 15 Product Compatibility The is suitable for use with
More informationAC SERIES LIFT CONTROLLER SYSTEMS AYBEY ELEKTRONIK
AC SERIES LIFT CONTROLLER SYSTEMS AYBEY ELEKTRONIK AC SERIES GENERAL SPECIFICATIONS CE certified as control board and control panel CAN-bus based shaft and group communication system Gets floor information
More informationELSEMA 3 Phase Control Board, 3PH2, 3PHE
3PH2 or 3PHE 3 Phase Control Board Features 2 versions - card only (3PH2) or enclosed with weatherproof box (3PHE) Built-in push buttons High-rated contactors for direct connection to the motor Separate
More informationVR2 R-NET LED R-NET LCD. Controller System Operation
VR2 R-NET LED R-NET LCD Controller System Operation 1.VR2 Controller Operation 1.1 Controls/JSM 1.2 Button/Indicator 1.3 Control System Status indication 1.4 Module Wiring 1.5 VR2 Locking / Unlocking The
More informationDEEP SEA ELECTRONICS PLC
COMPLEX SOLUTIONS MADE SIMPLE. DEEP SEA ELECTRONICS PLC DSE5320 AUTO MAINS FAILURE MODULE OPERATING MANUAL http://bestgenerator.spb.ru/?page_id=6765 Deep Sea Electronics Plc Highfield House Hunmanby North
More informationCONTROL PANEL ENGLISH INSTRUCTIONS MOTORLINE MC 1 / SEAV LRS 2102 R ++ SET
CONTROL PANEL ENGLISH INSTRUCTIONS MOTORLINE MC 1 / SEAV LRS 2102 R ++ SET 230 Volt Single Phase logic control panel for single motor only sliding gate, roller garage door, single leaf swing gate Integral
More informationDEEP SEA ELECTRONICS PLC
COMPLEX SOLUTIONS MADE SIMPLE. DEEP SEA ELECTRONICS PLC DSE5520 AUTOMATIC MAINS FAILURE CONTROL MODULE OPERATING MANUAL Deep Sea Electronics Plc Highfield House Hunmanby North Yorkshire YO14 0PH ENGLAND
More informationONYX FINGERPRINT PASSWORD LOCK MANUAL
ONYX FINGERPRINT PASSWORD LOCK MANUAL PREFACE 1. Electronic locks are sensitive and advanced products with fragile micro-chips and hardware. Please be aware that the position and type of environment the
More informationFIRING SYSTEMS 270 Old Dublin Rd PETERBOROUGH N.H PHONE FAX
FIRING SYSTEMS 270 Old Dublin Rd PETERBOROUGH N.H. 03458 PHONE 603-924-4251 FAX 603-924-6748 www.pyromate.com pyromate@monad.net Firmware Version 2.02 Page 1 of 19 Table of Contents Features of the Night
More informationTECHNICAL MANUAL FOR THE SKYCOM SHAFT ENCODER
FM40432 INTERNATIONAL LIFT EQUIPMENT LTD. Head Office Factory Units 1&2, Highams Park Ind Estate Wanlip Road Larkshall Road Syston London. E4 7HS Leicester, England LE7 1PD Telephone (020) 85279669 Telephone
More informationBosch Rexroth EFC3610 Frequency Inverter. Easy Start Guide L1 L2 L3 (+) B U V W
Bosch Rexroth EFC3610 Frequency Inverter Easy Start Guide L1 L2 L3 (+) B U V W The Bosch Rexroth EFC3610 Frequency Inverter range is available to order from inverterdrive.com This guide is intended to
More informationDryer. M720 Programming and Operation Manual. July 15, 2015 Revision 1.51
Dryer M720 Programming and Operation Manual July 15, 2015 Revision 1.51 Contents 1 Important Safety Information 1 1.1 FOR YOUR SAFETY - CAUTION!............................. 1 2 Control Overview 2 2.1
More informationOptidrive Applications Support Library
Optidrive Applications Support Library Application Note Title AN-ODV-3-038 Related Products Optidrive Eco Overview Level 3 Modbus RTU Control and Register Mapping 1 Fundamental - No previous experience
More informationKNX DALI Gateway Plus - User Manual
KNX DALI Gateway Plus - User Manual Item No.: LC-013-064 1. Product Description The KNX DALI gateway Plus is the interface between the KNX installation and the DALI lighting system. It allows up to 64
More informationSECTION SOLID-STATE REDUCED VOLTAGE STARTERS
SECTION 26 29 13.16 PART 1 - GENERAL 1.1 THE REQUIREMENT A. General: The CONTRACTOR shall provide solid-state reduced voltage motor starters, complete and operable, in accordance with the Contract Documents.
More informationIt is the installer's responsibility to follow all instructions in this manual and to follow correct electrical practice.
Important User Information User Manual: MCD Profibus Module Order Code: 175G9001 1. Important User Information Observe all necessary safety precautions when controlling the soft starter remotely. Alert
More informationMODBUS TCP MODULE INSTRUCTIONS. for use with WSIQ2/WSE
INSTRUCTIONS MODBUS TCP MODULE for use with WSIQ2/WSE WorldWide Electric Corporation Phone: 1-800-808-2131 Fax: 1-800-711-1616 www.worldwideelectric.net Product Compatibility This communications module
More informationRemote units Hands free or telephone handset options available. Master to remote and remote to master calling
(ORB/L/RS16 LOOP WIRED) Remote units Hands free or telephone handset options available Master to remote and remote to master calling Fully monitored for open and short circuit cable failures. Remotes connected
More informationInstallation Guide Modbus TCP Module
ENGINEERING TOMORROW Installation Guide Modbus TCP Module VLT Compact Starter MCD 201/MCD 202 VLT Soft Starter MCD 500 vlt-drives.danfoss.com Contents Installation Guide Contents 1 Introduction 3 1.1
More informationNote 1: Throughout this manual the Modbus Module Mk2 may simply be referred to as the module.
modbus Modbus RTU Actuator Control MFU Option Card Installation Manual Publication S175E V2.4 Issue 07/04 Modbus MFU Option Card Installation Manual Note 1: Throughout this manual the Modbus Module Mk2
More informationObserve all necessary safety precautions when controlling the soft starter remotely. Alert personnel that machinery may start without warning.
MCD Profibus Module Instructions Important User Information Installation Instruction: MCD Profibus Module Order Code: 175G9001 1. Important User Information Observe all necessary safety precautions when
More informationProfiler IV Feed Back Version DC Motor Control Board with Current Profiling Capability Variable travel length version
Profiler IV Feed Back Version DC Motor Control Board with Current Profiling Capability Variable travel length version The Profiler IV is a DC Motor Control board designed specifically for Motion Systems
More informationEclipse MCi. Variable Speed Drive Controller with Eclipse Operating System (EOS) 3rd Edition. VSD kits suitable for motors ranging from 0.4 to 2.
3rd Edition Variable Speed Drive Controller with Eclipse Operating System (EOS) Eclipse MCi VSD kits suitable for motors ranging from 0.4 to 2.2 kw www.elsema.com Controller with Eclipse Operating System
More informationModel: Available in : Sapphire Black and Glacier White
Model: Available in : Sapphire Black and Glacier White 1 Table of Contents Product Image 1 Locking/Unlocking the SmartStat 20 Table of Contents 2 Standby/Away Mode 21 What is a Programmable Room Thermostat?
More informationDEEP SEA ELECTRONICS PLC DSE334 Configuration Suite Software Manual
DEEP SEA ELECTRONICS PLC DSE334 Configuration Suite Software Manual Document Number 057-156 Author: Paul Gibbons DSE334 Configuration Suite Software Manual ISSUE 1 DSE334 Configuration Suite Software Manual
More informationHanatech Co., Ltd. I. Diagnostic Trouble Code
Hanatech Co., Ltd. Chapter 4 ULTRASCAN P1 Functions The functions you can choose when all the test vehicle details are selected properly are explained in this chapter of the manual. The actual list of
More informationSecurity System User Guide
Security System User Guide Setting the System: 1. Go to the keypad and key in your access code. (Alternatively, if you have a proximity tag, present your tag to the keypad.) Either - Full Set: 2. Press
More informationProfinet Module. User Manual. Contents
User Manual Contents 1 Important User Information... 2 2 Installation... 3 3 Connection... 4 4 Device Configuration... 5 5 Operation... 7 6 Packet Structures... 8 7 Network Design... 16 8 Specifications...
More informationINTEGRATED DISPLAY SYSTEMS
INTEGRATED DISPLAY SYSTEMS Lift-Net User Manual May 2004 integrated display systems 1555 W. Sherman Avenue, #170 Evanston, IL 60201 Technical Support Voice: (847) 475-2476 Fax: (847) 475-2535 Email: takecontrol@lift-net.com
More informationEthernet/IP Module. User Manual. Contents
User Manual Contents 1 Important User Information... 2 2 Installation... 3 3 Connection... 4 4 Device Configuration... 5 5 Operation... 8 6 Packet Structures... 9 7 Network Design... 18 8 Specifications...
More informationinstallation quick guide integrated access control & environmental monitoring
installation quick guide integrated access control & environmental monitoring Introduction This Installation Quick Guide is suitable for standard wallmountable AX300 controllers. Illustrative technical
More informationAC SMARTMOTION CONTROLLERs
AC SMARTMOTION CONTROLLERs for and Generic Slave FAULT LIST and TROUBLESHOOTING (Rev. 2.4: March 2016) SME S.p.A. Via della Tecnica, n 40 36071 Arzignano (VI) - ITALY Phone:+39 (0444) 470511 Fax: +39 (0444)
More information+ Lester Control Systems Ltd
+ Lester Control Systems Ltd Unit D, 18 Imperial Way, Croydon, Surrey, CR0 4RR. Tel: 020 8288 0668 Fax: 020 8288 0667 Email: info@lestercontrols.co.uk Web: www.lestercontrols.co.uk TECHNICAL MANUAL FOR
More informationEMX3 Soft Starter User Manual
EMX3 Soft Starter User Manual Part Number: 710-04840-00D CONTENTS Contents Section 1 Caution Statements...3 Section 2 Installation...4 2.1 Physical Installation... 4 2.2 Control Terminals... 4 2.3 Control
More informationTrio Application Control System Instruction Sheet
Trio Application Control System Instruction Sheet P/N 7580708_01 CAUTION The procedures detailed within this guide should only be performed by trained Nordson personnel or by persons cleared to do so by
More informationInstallation and Operation Back-UPS BR1000G-IN / BR1500G-IN
Installation and Operation Back-UPS BR1000G-IN / BR1500G-IN Important Safety Information Read the instructions carefully to become familiar with the equipment before trying to install, operate, service
More informationTouchpad User Guide. National Sales. Product Support. Freecall: Ph:
Touchpad User Guide National Sales Ph: 1300 306 125 sales@ias.net.au Product Support Freecall: 1800 354 434 support@ias.net.au Designed and Manufactured in Australia by: Innovative Air Systems Pty Ltd.
More informationSPS5.7. Operating Instructions. Notes
SPS5.7 Operating Instructions Stanton Pottery Supplies Ltd., Canal Lane, Westport Lake, Tunstall, STOKE-ON-TRENT, Staffordshire, England. ST6 4NZ 24 Tel: +44 (0)1782 835467 Issue: 1.0A Fax: +44 (0)1782
More informationInControl INCONTROL OVERVIEW
INCONTROL OVERVIEW InControl uses smartphone and in-vehicle mobile technology, to remotely connect the vehicle to a number of services and convenience features. Note: For further information, access the
More informationOperating Instructions Extended Cascade Controller MCO 101
Operating Instructions Extended Cascade Controller MCO 101 VLT AQUA Drive FC 200 Extended Cascade Controller Option Contents Contents 1. Safety and precautions 3 Safety Instructions 3 Avoid unintended
More information6-1-6 Types of Errors
6-1-6 Types of Errors The type of that has occurred can be identified by checking the indicators on the front of the CPU Unit and the Power Supply Unit, or by using the CX-Programmer to check the status.
More informationMAIN CONTROL BOARD USER MANUAL V - 3.0
MAIN CONTROL BOARD USER MANUAL V - 3.0 INDEX SECTION 1- WARNINGS...2 SECTION 2- ELECTRICAL SPECIFICATIONS...3 SECTION 3- TECHNICAL SPECIFICATIONS...4 SECTION 4- EXPLANATION OF TERMINALS...5 SECTION 5-
More informationError Messages
Processing Section 11-2 11-2-5 Messages The following tables show messages for s which can occur in CSseries PLCs and indicate the likely cause of the s.!caution Always check the safety of the controlled
More informationHandbook ASI-PRG-ADR. AS-Interface Addressing Device. Festo AG & Co de 0004a
Handbook ASI-PRG-ADR AS-Interface Addressing Device Festo AG & Co. 360 039 de 0004a AS-Interface is a registered Trademark of the AS-International Association We recognise a duty to make a contribution
More informationOperating instructions Addressing unit AC1144
Operating instructions Addressing unit AC1144 UK 701447 / 04 02 / 2004 Contents Functions and features... 3 Safety instructions... 3 Introduction to the AS-interface version 2.1... 3 Structure of the addressing
More informationSUNRISE MEDICAL EDUCATION DEPARTMENT INFO. VR2 Codes Display and Code description
VR2 Codes Display and Code description NOTE: A Complete Description Taken from the official PG Drives Engineering Manual is described on the next 3 pages TRIP CODE Details from Page listing Trip Code 1-1
More informationIQ-MP Gateway. Version apr Electrocom Rødeledsvej 95 DK-5700 Svendborg Denmark Tel :
IQ-MP Gateway Version 4.009 28. apr. 2011 Electrocom Rødeledsvej 95 DK-5700 Svendborg Denmark Tel : +45 8880 7580 www.electrocom.dk p. 2 Description The IQ-MP Gateway is a communications module, which
More informationInstallation Guide EtherNet/IP Module
ENGINEERING TOMORROW Installation Guide EtherNet/IP Module VLT Compact Starter MCD 201/MCD 202 VLT Soft Starter MCD 500 vlt-drives.danfoss.com Contents Installation Guide Contents 1 Introduction 3 1.1
More informationInstallation, Start-up and Operating Instructions
Installation, Start-up and Operating Instructions EVOLUTION SMART SENSOR FOR ZONING Cancels: NEW II ZONESMS-0-1 7-04 NOTE: Read the entire instruction manual before starting the installation. This symbol
More informationCopyright: December 2017 Nidec Issue: E
General Information The manufacturer accepts no liability for any consequences resulting from inappropriate, negligent or incorrect installation or adjustment of the optional parameters of the equipment
More informationInteset INT422-3 Programming Technical Document
This document is meant to inform the sophisticated user of our remote of some of the technical aspects, features and capabilities of our remote. Our User Guide provides the same information but in a simplified
More informationSimplified Operating Instructions T105-C / T108-C / T106-C / T17B-C DISPLAYS DAY OR DAY BLOCK PROG 00:0000 PROG PROG ALWAYS OFF
Button Operations Simplified Operating Instructions T105-C / T108-C / T106-C / T17B-C R - Reset (with pen or other pointed instrument). Y - Enters function setup. +/- Buttons to scroll through icons. Y
More informationControl Equipment Limited 96 Zone Discovery Panel, 32 Zone Voyager Panel and Integra Network Repeater 40- Character User Manual
Created by: A.C. Revised by: G.G. Approved by: JBJ Control Equipment Limited 96 Zone Discovery Panel, 32 Zone Voyager Panel and Integra Network Repeater 40- Character User Manual Table of Contents 1. Introduction...3
More informationREMOTE KEYPAD with NFC Tag (KPT-32N, KPT-32N-F1)
REMOTE KEYPAD with NFC Tag (KPT-32N, KPT-32N-F1) April 01st, 2016 Identifying the Parts 1. Siren 2. Orange LED: Home Arm Key 3. Red LED: Away Arm Key 4. Panic Alarm (if enabled) - Press both 1 and 3 to
More informationSidewinder Pumps Inc. AC Timer/Controller
Sidewinder Pumps Inc. AC Timer/Controller Page 1 of 12 Rev 032417 Table of Contents 1. Warnings-------------------------------------------------------------------------------------------------- 3 1.1.
More informationAS Keypad User Manual
AS Keypad User Manual Specifications Operating Voltage: 12~24 VAC/DC Current Draw: TBA Input: request-to-exit (for Relay 1) time out reed switch contact (for Relay 1) Output: Relay 1: N.O./N.C./Com. Output
More informationChallenger Series Administrators Manual
Challenger Series Administrators Manual P/N MAADMN-TS1016 REV 07 ISS 20AUG15 Copyright Trademarks and patents Manufacturer Agency compliance Contact information 2015 UTC Fire & Security Australia Pty Ltd.
More information121000TP227S USER'S MANUAL
121000TP227S USER'S MANUAL TABLE OF CONTENTS FEATURE LIST SAFETY INSTRUCTIONS INTRODUCTION LOCATION OF CONTROLS FUNCTION BUTTONS MENU SETTINGS CALLER ID INFORMATION DISPLAY MESSAGES CALLER ID SYSTEM OPERATION
More informationEATON 5S 850/1200/1600
www.eaton.com EATON 5S 850/1200/1600 Installation and user manual Packaging EATON 5S 1 2 3 5 Caution! l Before installing the Eaton 5S, read the booklet 3 containing the safety instructions to be respected.
More informationplc operation Topics: The computer structure of a PLC The sanity check, input, output and logic scans Status and memory types 686 CPU
plc operation - 8.1 Topics: The computer structure of a PLC The sanity check, input, output and logic scans Status and memory types Objectives: Understand the operation of a PLC. For simple programming
More informationVARIO REMOTE CONTROL INSTRUCTIONS
VARIO REMOTE CONTROL INSTRUCTIONS 1. LED Status Indicators, Using the Remote and Operating Modes 2. Power Adjust 3. Photocell Sensitivity 4. Wiring of Remote Switch or Input (Telemetry Input) 4a.Telemetry
More informationUser Manual Digi-Sense 12-Channel Benchtop Data Logging Thermocouple Thermometer
User Manual Digi-Sense 12-Channel Benchtop Data Logging Thermocouple Thermometer Model: 92000-01 THE STANDARD IN PRECISION MEASUREMENT Table of Contents Introduction... 3 Unpacking... 3 Initial Setup...3
More informationHT-52 ASANSÖR KUMANDA KARTI (LİFT CONTROL CARD)
HT-52 ASANSÖR KUMANDA KARTI (LİFT CONTROL CARD) KULLANIM KILAVUZU (USER MANUEL) EN81-1 / 2 SAFETY NOTES HEYTECH HT-52 Control card, comply with EN81-1/2 standard, is an integrated and electronic control
More informationDNP Points List and Implementation
S&C 6800 Series Automatic Switch Control DNP Points List and Implementation Table of Contents Section Page Section Page DNP Points List for 6801 Controls...1 6801 Status Points...2 6801 Double-bit Status
More informationHYDROTHUNDER WIRING & CIRCUIT INFORMATION C H A P T E R F I V E
HYDROTHUNDER C H A P T E R F I V E WIRING & CIRCUIT INFORMATION WARNING: Failure to reconnect all ground wires or to replace metal shields and covers with each mounting screw installed and securely tightened
More informationIDS. Users Guide to Keypad Functions S E C U R I T Y MANUAL NO D ISSUED NOVEMBER 2002 VERSION 2.
INHEP DIGITAL IDS S E C U R I T Y Users Guide to Keypad Functions MANUAL NO. 700-146-01D ISSUED NOVEMBER 2002 VERSION 2.17 Summary of Operation A rm/ disarm [#] + [USER CODE] Quick Quick Quick Away Arm
More informationElectrical Demand Specification (Reference SOP: )
Project: Equipment Description: Location: Equipment No.: Project No: Protocol No.: Content Index 1. GENERAL...3 Design Standards...3 1.1. Standards...3 2. DESIGN...3 2.1. Safety...3 2.2. Circuit protection...3
More informationMultifunctional with high performance. Browser based user interface. Universal interface design
Multifunctional with high performance Optimal functionality through consequent innovation was the motto for the development of the new MPK control system generation 411. The objective was to develop a
More informationStill provides for large security installations, but expands the access control capabilities.
MODEL 3000 / ACCESS 4000 Programmer s Manual - Mem. Default. Rev 5.0 [MENU 7-5-2] p 1 Memory Defaulting Memory Configuration Options There are a range of Memory Configurations available in the Model 3000/4000.
More informationOperating instructions. Speed monitor D / / 2014
Operating instructions Speed monitor D200 80005257 / 00 05 / 2014 Contents 1 Preliminary note...4 1.1 Symbols used...4 1.2 Warning signs used...4 2 Safety instructions...5 2.1 General...5 2.2 Target group...5
More informationCCU Manual (English) Pd_CM_003. Version A.3
CCU Manual (English) Pd_CM_003. Version A.3 ChargeStorm AB March 16, 2018 Contents 1 Introduction 4 1.1 Connecting the CCU.............. 4 1.2 Overview.................... 6 2 System 8 3 Configuration
More informationIO-INTERFACE. Procon. INSTALLATION MANUAL Version 1.01 MITSUBISHI ELECTRIC FOR INSTALLERS
Procon IO-INTERFACE FOR INSTALLERS INSTALLATION MANUAL Version 1.01 For safe and correct use, please read this installation manual thoroughly before installing the PROCON IO-INTERFACE. MITSUBISHI ELECTRIC
More informationSoftstarters Type PSTX Fieldbus communication, Anybus CompactCom DeviceNet
Softstarters Type PSTX Fieldbus communication, Anybus CompactCom DeviceNet 1SFC132084M0201 June 2017 Power and productivity for a better world 1SFC132084M0201 1SFC132084M0201 INFORMATION When fastening
More informationMCD 200 MCD 500. Remove the Profibus Module using the following procedure: 1. Remove power from the module.
Installation INSTALLATION INSTRUCTIONS: MCD PROFIBUS MODULE Order Code: 175G9001 1. Installation 1. Remove control power and mains supply from the soft starter. 2. Attach the module to the soft starter
More information2 Table of Contents 1. TABLE OF CONTENTS. 1. Table of Contents Introduction Wiring Diagram Terminals Review...
TPR-6 Temperature Protection Relay Instruction Manual Ver. June 1 st 2010 2 Table of Contents 1. TABLE OF CONTENTS 1. Table of Contents... 2 2. Introduction... 3 3. Wiring Diagram... 5 4. Terminals Review...
More informationModel: Available in : Sapphire Black and Glacier White
1 Model: Available in : Sapphire Black and Glacier White 1 Table of Contents Product Image 1 Locking/Unlocking the SmartStat 20 23 Table of Contents 2 Standby/Away Mode Mode 21 24 What is a Programmable
More informationRegenerative Power Module And Common Bus RPM Panels Instruction Manual
Regenerative Power Module And Common Bus RPM Panels Instruction Manual Part Number September 2010 Copyright 2010 Magnetek Material Handling PRODUCT MANUAL SAFETY INFORMATION Magnetek, Inc. (Magnetek)
More informationT0046 PROFESSIONAL LAN CABLE TESTER USER GUIDE
T0046 PROFESSIONAL LAN CABLE TESTER USER GUIDE INDEX 1. Interfaces and Controls...1 2. Power On...2 3. Setup...2 3.1 To set the UNIT...3 3.2 To set the LAN Length Adjustment...3 3.3 To set the COAX Length
More information900 MHz Digital Two-Line Cordless Speakerphone with Answering System 9452 with Caller ID/Call Waiting
USER S MANUAL Part 2 900 MHz Digital Two-Line Cordless Speakerphone with Answering System 9452 with Caller ID/Call Waiting Please also read Part 1 Important Product Information AT&T and the globe symbol
More informationProduct Overview. Additional Information. Using the EWS 102. Fitting. Variants. Wiring: Sensor & Relays. Control Signal.
Product Overview The EWS 102 Elevator Load Weighing Sysytem is a compact easy to install device that provides a comprehensive control system for use with a range of sensor/application types. The EWS 102
More informationMiniature circuit-breaker versus electronic selectivity module Selective monitoring of 24 V DC load circuits
Miniature circuit-breaker versus electronic selectivity module Selective monitoring of 24 V DC load circuits In modern plant and machine construction all 24 V DC loads whether rugged electro-mechanical
More informationSUPERPLEX. User s Manual. High performance, simplified wireless home security controller. Products that work. Software Release: V2.
SUPERPLEX User s Manual Products that work Software Release: V2.5 KE-MOBILEHQ-12- High performance, simplified wireless home security controller Thank you for purchasing this Kingdom Electronics product.
More informationColour Graphic Terminal User Manual. Rev 3.1
Integriti. Colour Graphic Terminal User Manual. 1 Colour Graphic Terminal User Manual. Rev 3.1 2013-2014. Inner Range Pty. Ltd. Part Number: 636000U 2 Integriti. Revision 3.1 June 2014. SYSTEM DETAILS
More informationADVANTAGE DKE QUICK START GUIDE. 2 Make sure you have everything shown here. 3. What s what? All important internal components labeled for you
1 of 6 START HERE 1 Carefully unpack box. 2 Make sure you have everything shown here. 3 Unlock and remove front panel of keypad unit, then using carriage bolts and hex nuts, attach unit to pedestal as
More informationAMS Controls Model MP450Z
AMS Controls Model MP450Z SHEAR 7 8 9 4 5 6 1 2 3 CAL * PRG RUN STOP 0.CE MP400 SERIES ENT LENGTH CONTROL SYSTEMS Push button and Front Panel Selector Switches SHEAR Run Stop The SHEAR button is an illuminated
More informationDIGITAL PUMP CONTROLLER. Model Version October 24, 2011
DIGITAL PUMP CONTROLLER Model 9954-1 Version October 24, 2011 9954-1 Controller Interconnection Diagram PROGRAMMABLE VOLT-FREE CONTACT (10A 240vAC) (FACTORY FITTED OPTION) FOR REMOTE SIGNALLING CONTROL
More informationThis section describes how to install the following options: #!! #!% *+! Use Figure 8-1 to locate the system board features.
This section describes how to install the following options: Expansion cards Memory upgrades Microprocessor upgrades This section also includes instructions for replacing the system battery, if necessary.!"
More information1-1 AC DRIVE OVERVIEW EXERCISE OBJECTIVE
1-1 EXERCISE OBJECTIVE Familiarize yourself with the AC Drive. Read AC Drive parameter settings. Set the basic AC Drive parameters to control the Four-Pole Squirrel-Cage Induction Motor. DISCUSSION Figure
More informationProfibus DP Expansion Board
Profibus DP Expansion Board Catalog No. EXB014A01 Installation and Operating Manual 8/03 MN1323 Table of Contents Section 1 General Information................................... 1-1 Introduction.........................................
More informationTroubleshooting. Resetting the System. Problems Following Initial System Installation. First Steps Checklist CHAPTER
CHAPTER 6 This chapter helps you identify and solve problems that might occur while you are using the Cisco CDE110. If you are unable to resolve your server problems on your own, contact Cisco Technical
More informationUsing MDC Manager to Manage Power Settings
AddendumA Using MDC Manager to Manage Power Settings This addendum explains how to use the MDC Manager to configure and manage the power settings for the M7. It is organized into the following sections:
More informationSOLAR Basic. Operating instructions for electronic high-security locks
SOLAR Basic Operating instructions for electronic high-security locks Gebäude Sicherheitstechnik Vertriebs GmbH, 34123 Kassel Solar-Basic (DE, EN, FR)-17000000 Rev. 1.3 / 01-2015 Table of contents General
More informationGS400. Electronic Auto-Ranging DIN Panel Mounted Positioner
GS400 Electronic Auto-Ranging DIN Panel Mounted Positioner Features * AC (115/230V) and DC (24V) versions available. * Accepts either current or voltage command signal and either current, voltage, or three
More informationFIRE RESISTANT ROLLER SHUTTER DOOR
FIRE RESISTANT ROLLER SHUTTER DOOR OPERATING & MAINTENANCE INSTRUCTIONS Page 1 Operating Instructions for Phoenix Tube Motor Fire Resisting Roller Shutters Opening and Closing the Shutter This is done
More informationOperating instructions. Switching amplifier DN0210 DN / / 2015
Operating instructions Switching amplifier DN0210 DN0220 UK 80011079 / 00 01 / 2015 Contents 1 Preliminary note...4 1.1 Symbols used...4 1.2 Warning signs used...4 2 Safety instructions...5 2.1 General...5
More information