Series IZH10. Handheld Electrostatic Meter. How to Order. Accessories and Option / Part Number for Individual Parts.

Size: px
Start display at page:

Download "Series IZH10. Handheld Electrostatic Meter. How to Order. Accessories and Option / Part Number for Individual Parts."

Transcription

1 Peak G 15min Handheld Electrostatic Meter Series IZH10 How to Order IZH10 Option Nil H None High-voltage measuring handle Accessories and Option / Part Number for Individual Parts The ground wire and soft case are attached to the IZH series. Ground wire (1.5 m) / Accessories IZH-A-01 Soft case / Accessories IZH-B-01 High-voltage measuring handle / Option IZH-C-01 Measured Potential Press for 6sec AUTO -OFF Extension Press! Press! PEAK / BOTTOM MODE Display Normal Bottom BATTERY 1.5V x 2 LR6 MADE IN JAPAN ±20.0kV Extends at Ground wire High-voltage measuring handle Soft case Note) Be sure to use a high-voltage measuring handle in situations such as during highvoltage measurement when there is a possibility of personnel coming in contact with electricity. Specifications Model Rated charge amount range Minimum display unit Measurement distance Power supply Note 1) Display accuracy Environmental resistance Enclosure Operating temperature range Operating humidity range Vibration resistance Material Mass Standards Accessories Note 1) 2A alkali dry cell batteries are not included, and must be acquired separately. Note 2) When new alkali dry cell batteries are used at ordinary temperature Impact resistance IZH10 ±20.0 kv 0.1 kv (±1.0 kv to ±20.0 kv), 0.01 kv (0 to ±0.99 kv) 50 mm (between sensor part and measured target) 1.5 VDC 2A alkali dry cell battery, 2 pcs (continuous use for 15 hours or more, see Note 2) ) ±5% F.S. ±1 digit IP40 Operating: 0 to 40 C, Stored: 10 to 60 C (with no freezing or condensation) Operating/Stored: 35 to 85% R.H. (with no condensation) 10 to 150 Hz at whichever is smaller of 1.5 mm amplitude or 98 m/s 2 acceleration, in X, Y, Z directions for 2 hs. each (De-energized) 100 m/s 2 in X, Y, Z directions 3 times each (De-energized) Display part: PC/ABS Sensor part: ABS 85 g (excluding dry cell batteries) CE marking Ground wire, Soft case

2 Normal Press! Peak Extends at 15min Press! Bottom Handheld Electrostatic Meter Series IZH10 Dimensions (Unit: mm) Display part Measured Potential ±20.0kV AUTO -OFF Extension Press for 6sec PEAK / BOTTOM MODE Display kv BATTERY 1.5V x 2 LR6 MADE IN JAPAN G LIGHT 2 x ø SMC 110 Do not apply a strong impact on the sensing part. Sensor part 87.5 ø (7.5) (175) IZS IZD IZE IZH (12.3) (9.3) (55)

3 Press! Normal Peak Extends at 15min Press! Bottom Series IZH10 Names and Functions of Individual Parts Peak display P Bottom display b LCD display Display of charged electricity Display of peak/bottom value Measured Potential ±20.0kV AUTO -OFF Extension Press for 6sec kv Ground terminal PEAK / BOTTOM MODE Display BATTERY 1.5V x 2 LR6 MADE IN JAPAN G Battery LOW L button Power ON/OFF Mode switching LIGHT LIGHT button Backlight ON/OFF LR6 dry cell battery (2 pcs) Function Details A Peak/Bottom display function The function constantly detects and updates the maximum and minimum electrostatic potential value and allows holding the display value. B Reset function The reading of the measured voltage can be adjusted to zero. The reading can be corrected within ±5% of F.S. from the factory-set condition. C LOW battery indicator When the batteries are low it is displayed in two stages: Battery LOW and Replace Battery. The battery level is indicated by the flashing or lightening up of on the display. flashes: Prepare to replace batteries. lights up: Replace batteries with new ones. D Auto power-off function If no button is operated for 5 min. or more while the power supply is on, the power supply will turn off automatically. When the [] button is pressed for 6 sec. or more with the power supply off, continuous operating time while no button is pushed will extend to 15 min. E Light-up of backlight The display can be easily seen in the dark. The backlight will be turned on and off by every press of the [LIGHT] button. F Displayed digit change function The minimum display digit is changed for the charged potential between 0.99 kv to kv. Error Display Error description Error display Condition Zero clear error A charge over ±5% F.S. of default potential is applied to the sensor. The indication lasts approx. 1 sec. and then measurement mode returns automatically. There will be a slight displacement, depending on the deviation of the sensor itself and ambient environment. Sensor error System error Measurement error Cable breakage The sensor breaks. Internal display error. A charge over the upper limit of the measured voltage range is applied to the sensor, or the distance to the measured target is outside of specified range. A charge over the lower limit of the measured voltage range is applied to the sensor, or the distance to the measured target is outside of specified range. A broken cable prevents accurate measurement. The charge amount can be detected, but it will not change the displayed value. 1102

4 Series IZH10 Handheld Electrostatic Meter Precautions Be sure to read this before handling. Refer to front matters 58 and 59 for Safety Instructions. Warning Handling Precautions 1. Do not make any modifications (including exchanging the printed circuit board) to the product. It may cause human injuries and damage. 2. Use the device in the condition of specified range. Using it out of the specified range may result in fires, electric shock, or damage. Confirm the specifications before using. 3. Measurement near high-voltage Avoid measuring near high-voltage exceeding specifications as it can be dangerous. 4. Handling of ground wire Be sure to provide a ground wire to ensure safety and highaccuracy measurement when using the sensor. Also, if the ground wire is not connected properly, the power is pooled in the sensor part and/or ground terminal, which can discharge to an operator s hand. Handle the sensor part and ground terminal carefully. If grounding is not provided, Measurement accuracy gets worse. The sensor is charged and can discharge to an operator s hand. 5. Do not apply strong impact. Do not drop, allow collision or apply excessive shock to the sensor when handling. It can result in damage of the sensor and accidents. 6. Distance measurement is 50 mm. Use display of label attached to the sensors as a guide. Warning Operating Environment 1. Handheld electrostatic meters are CE marked; however, they are not equipped with surge protection against lighting. Lighting surge countermeasures should be applied directly to system components as necessary. 2. Handheld electrostatic meters do not have an explosion proof rating. Never use in the presence of an explosive gas as this may cause a serious explosion. Approx. 50 mm Distance measurement Detection area Detection hole 7. The measurement of a part with a high-charge potential can be highly dangerous as it can cause a discharge to the user s hand. In this case, use a handle specific for measuring high voltage, which is available as an option, and wear rubber gloves, etc. Also, gradually bring the sensor part close to the measured target from a distance, and stop the measurement immediately when the displayed value overflows (HHH) or underflows (LLL). (A target with a high-charge potential is very dangerous. The measured value does not changed even if the distance is shortened.) IZS IZD IZE IZH 1103

5 Safety Instructions These safety instructions are intended to prevent hazardous situations and/or equipment damage. These instructions indicate the level of potential hazard with the labels of Caution, Warning or Danger. They are all important notes for safety and must be followed in addition to International Standards (ISO/IEC), Japan Industrial Standards (JIS) 1) and other safety regulations 2). 1) ISO 4414: Pneumatic fluid power General rules relating to systems. ISO 4413: Hydraulic fluid power General rules relating to systems. IEC : Safety of machinery Electrical equipment of machines. (Part 1: General requirements) ISO : Manipulating industrial robots -Safety. JIS B 8370: General rules for pneumatic equipment. JIS B 8361: General rules for hydraulic equipment. JIS B : Safety of machinery Electrical equipment of machines. (Part 1: General requirements) JIS B : Manipulating industrial robots - Safety. etc. 2) Labor Safety and Sanitation Law, etc. Caution: Operator error could result in injury or equipment damage. Warning: Operator error could result in serious injury or loss of life. Danger : In extreme conditions, there is a possibility of serious injury or loss of life. Warning 1. The compatibility of the product is the responsibility of the person who designs the equipment or decides its specifications. Since the product specified here is used under various operating conditions, its compatibility with specific equipment must be decided by the person who designs the equipment or decides its specifications based on necessary analysis and test results. The expected performance and safety assurance of the equipment will be the responsibility of the person who has determined its compatibility with the product. This person should also continuously review all specifications of the product referring to its latest catalog information, with a view to giving due consideration to any possibility of equipment failure when configuring the equipment. 2. Only personnel with appropriate training should operate machinery and equipment. The product specified here may become unsafe if handled incorrectly. The assembly, operation and maintenance of machines or equipment including our products must be performed by an operator who is appropriately trained and experienced. 3. Do not service or attempt to remove product and machinery/equipment until safety is confirmed. 1. The inspection and maintenance of machinery/equipment should only be performed after measures to prevent falling or runaway of the driven objects have been confirmed. 2. When the product is to be removed, confirm that the safety measures as mentioned above are implemented and the power from any appropriate source is cut, and read and understand the specific product precautions of all relevant products carefully. 3. Before machinery/equipment is restarted, take measures to prevent unexpected operation and malfunction. 4. Contact SMC beforehand and take special consideration of safety measures if the product is to be used in any of the following conditions. 1. Conditions and environments outside of the given specifications, or use outdoors or in a place exposed to direct sunlight. 2. Installation on equipment in conjunction with atomic energy, railways, air navigation, space, shipping, vehicles, military, medical treatment, combustion and recreation, or equipment in contact with food and beverages, emergency stop circuits, clutch and brake circuits in press applications, safety equipment or other applications unsuitable for the standard specifications described in the product catalog. 3. An application which could have negative effects on people, property, or animals requiring special safety analysis. 4. Use in an interlock circuit, which requires the provision of double interlock for possible failure by using a mechanical protective function, and periodical checks to confirm proper operation. Front matter 58

6 Safety Instructions Caution The product is provided for use in manufacturing industries. The product herein described is basically provided for peaceful use in manufacturing industries. If considering using the product in other industries, consult SMC beforehand and exchange specifications or a contract if necessary. If anything is unclear, contact your nearest sales branch. Limited Warranty and Disclaimer/Compliance Requirements The product used is subject to the following Limited Warranty and Disclaimer and Compliance Requirements. Read and accept them before using the product. Limited Warranty and Disclaimer 1. The warranty period of the product is 1 year in service or 1.5 years after the product is delivered. 3) Also, the product may have specified durability, running distance or replacement parts. Please consult your nearest sales branch. 2. For any failure or damage reported within the warranty period which is clearly our responsibility, a replacement product or necessary parts will be provided. This limited warranty applies only to our product independently, and not to any other damage incurred due to the failure of the product. 3. Prior to using SMC products, please read and understand the warranty terms and disclaimers noted in the specified catalog for the particular products. 3) Vacuum pads are excluded from this 1 year warranty. A vacuum pad is a consumable part, so it is warranted for a year after it is delivered. Also, even within the warranty period, the wear of a product due to the use of the vacuum pad or failure due to the deterioration of rubber material are not covered by the limited warranty. Compliance Requirements When the product is exported, strictly follow the laws required by the Ministry of Economy, Trade and Industry (Foreign Exchange and Foreign Trade Control Law). Front matter 59

0.01kV (0 to ±0.99 kv)

0.01kV (0 to ±0.99 kv) Handheld Electrostatic Meter 10 Series Easy-to-use handheld electrostatic meter Rated charge amount range: ±20.0 kv Minimum display unit: 0.1kV (±1.0 to ±20.0 kv) 0.01kV (0 to ±0.99 kv) RoHS IZE Check

More information

High Pressure E/P Regulator. ITVH Series

High Pressure E/P Regulator. ITVH Series Doc. No. DIQ-69200-OM002-A P R O D U C T N A M E High Pressure E/P Regulator MODEL/ Series/ Product Number ITVH Series Install and operate the product only after reading the Operation Manual carefully

More information

Controller setting kit Software (ACT Controller)

Controller setting kit Software (ACT Controller) No.JXC -OMU0010 PRODUCT NAME Controller setting kit Software (ACT Controller) MODEL/ Series JXC-W2 series Contents 1. Safety Instructions... 2 2. Product Outline... 4 3. Operation explanation... 5 3.1

More information

JXC-W1 (JXC#3 Series)

JXC-W1 (JXC#3 Series) Product Name Controller Setting Software (For 4-axis Step Motor Controller) MODEL/ Series/ Product Number JXC-W1 (JXC#3 Series) Contents 1. Safety Instructions... 3 2. Product Specifications... 5 2.1 Features

More information

Product Name. Controller Setting Software (For 3-axis Step Motor Controller) MODEL/ Series/ Product Number. JXC#2 Series

Product Name. Controller Setting Software (For 3-axis Step Motor Controller) MODEL/ Series/ Product Number. JXC#2 Series No.JXC -OMU0024 Product Name Controller Setting Software (For 3-axis Step Motor Controller) MODEL/ Series/ Product Number JXC#2 Series CD-ROM included JXC-MA1 Controller Setting Software for JXC#2 Series

More information

Digital Gap Checker. ON: Placed. Workpiece. Large gap. Workpiece. Workpiece. Small gap. Detection surface Detection nozzle. Air

Digital Gap Checker. ON: Placed. Workpiece. Large gap. Workpiece. Workpiece. Small gap. Detection surface Detection nozzle. Air -Color Display Digital Gap Checker. to.5 mm (Displayable/Settable range: to ) G type Rated detection distance range ON: Placed H type Rated detection distance range Workpiece.5 to. mm (Displayable/Settable

More information

Electrostatic Sensor Monitor IZE11

Electrostatic Sensor Monitor IZE11 PRODUCT NAME Electrostatic Sensor Monitor MODEL/ Series IZE11 Table of Contents Safety Instructions 2 Model Identification and How to Order 7 Summary of Product parts 8 Mounting and Installation 10 Installation

More information

Doc. no. LEC-OM00501 PRODUCT NAME. Teaching Box for Electric actuator. MODEL / Series. LEC-T1 Series. Applicable models : For Series LECP, Series LECA

Doc. no. LEC-OM00501 PRODUCT NAME. Teaching Box for Electric actuator. MODEL / Series. LEC-T1 Series. Applicable models : For Series LECP, Series LECA Doc. no. LEC-OM00501 PRODUCT NAME Teaching Box for Electric actuator MODEL / Series LEC-T1 Series Applicable models : For Series LECP, Series LECA Contents 1. Teaching Box Specifications... 7 1.1 Outline

More information

Document No. LEC-OM Product name. LEC Serial Communication Information. Model/ Series. LEC 6 Series. SMC Corporation

Document No. LEC-OM Product name. LEC Serial Communication Information. Model/ Series. LEC 6 Series. SMC Corporation Document No. LEC-OM02201 Product name LEC Serial Communication Information Model/ Series LEC 6 Series SMC Corporation Contents 1. Safety Instructions 2 2. Outline 5 3. What is LEC serial communication?

More information

Flow Monitor PF2A20# PF2W20# PF2D20#

Flow Monitor PF2A20# PF2W20# PF2D20# PRODUCT NAME Flow Monitor MODEL / Series / Product Number PF2A20# PF2W20# PF2D20# Table of Contents Safety Instructions 2 Model Indication and How to Order 9 Summary of Product parts 12 Definition and

More information

LEC-T1 Series Applicable models: For Series LECP6,LECPMJ For Series LECA6 For Series LECPA (TB Ver2.1 or more)

LEC-T1 Series Applicable models: For Series LECP6,LECPMJ For Series LECA6 For Series LECPA (TB Ver2.1 or more) Doc. no. LEC-OM00506 PRODUCT NAME Teaching Box for Electric actuator MODEL / Series/Product Number LEC-T1 Series Applicable models: For Series LECP6,LECPMJ For Series LECA6 For Series LECPA (TB Ver2.1

More information

OPERATION MANUAL E/P REGULATOR MODEL NAME. Series. For DeviceNet TM CONTENTS. Contents. Safety Instructions. Precautions for Handling P3-4

OPERATION MANUAL E/P REGULATOR MODEL NAME. Series. For DeviceNet TM CONTENTS. Contents. Safety Instructions. Precautions for Handling P3-4 OPERATION MANUAL E/P REGULATOR MODEL NAME ITV*0*0 *0*0-DE**** series Series For DeviceNet TM CONTENTS TM Contents Safety Instructions P1 P2 Precautions for Handling P3-4 Wiring and LED display P5-6 Mounting

More information

The importance of the static electric control is put on confirming the actual status.

The importance of the static electric control is put on confirming the actual status. Electrostatic Sensor IZD10/IZE11 Series Potential measurement: ±20 kv (detected at a 50 mm distance) ±0.4 kv (detected at a 25 mm distance) Detects the electrostatic potential and outputs in an analog

More information

7032 Digital-Analog Multimeter

7032 Digital-Analog Multimeter 7032 Digital-Analog Multimeter OPERATOR S MANUAL CONTENTS: 1. Safety precautions and procedures 1 1.1. Preliminary 1 1.2. During Use 2 1.3. After Use.. 2 2. General Description. 3 3. Preparation for Use..

More information

EtherNet/IP TM SI unit

EtherNet/IP TM SI unit EX##-####### PRODUCT NAME EtherNet/IP TM SI unit MODEL / Series / Product Number UIUSP-SEN#-DUO02979 Contents Safety Instructions 2 How to Order 7 Summary of Product elements 8 Installation and Cabling

More information

Line reactors SINAMICS. SINAMICS G130 Line reactors. Safety information 1. General. Mechanical installation 3. Electrical installation

Line reactors SINAMICS. SINAMICS G130 Line reactors. Safety information 1. General. Mechanical installation 3. Electrical installation Safety information 1 General 2 SINAMICS SINAMICS G130 Mechanical installation 3 Electrical installation 4 Technical specifications 5 Operating Instructions Control version V4.7 04/2014 A5E00331462A Legal

More information

Pressure Sensor Controller PSE300

Pressure Sensor Controller PSE300 PRODUCT NAME Pressure Sensor Controller MODEL / Series / Product Number PSE300 Table of Contents Safety Instructions 2 Model Indication and how to order 7 Summary of Product parts 8 Mounting and Installation

More information

Fieldbus system (SI unit compatible CompoNet)

Fieldbus system (SI unit compatible CompoNet) PRODUCT NAME Fieldbus system (SI unit compatible CompoNet) MODEL / Series / Product Number EX12#-SCM# Table of Contents Safety Instructions 2 Product Summary 7 Model Identification and How to Order 7 Names

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS Adaptor Model No. CZ-CFUNC1U For your safety Read the following instructions carefully, and carry out secure installation and electrical work. The precautions given in this manual

More information

TOP - 1. Instruction Manual. Version 1.0 Produced in Jan. 2004

TOP - 1. Instruction Manual. Version 1.0 Produced in Jan. 2004 Version 1.0 Produced in Jan. 2004 Instruction Manual LCD monitor IV-08MP Thank you for purchasing the SHARP IV-08MP LCD monitor. Read this introductory instruction manual carefully to thoroughly familiarize

More information

Fan Type Ionizer. IZF10R Series

Fan Type Ionizer. IZF10R Series PRODUCT NAME Fan Type Ionizer MODEL / Series / Product Number IZF10R Series Contents Safety Instructions... 2 1. How to Order... 7 1-1. Product... 7 1-2. Accessories... 7 1-3. Maintenance parts... 8 1-4.

More information

EF-S1 SERIES. Continuously check invisible static electricity in lines. Constantly check static in lines!

EF-S1 SERIES. Continuously check invisible static electricity in lines. Constantly check static in lines! 1215 PHOTO PHOTO SAFETY USE SERIES Related Information General terms and conditions... F- General precautions... P.1595 guide... P.1155~ MEASUREMENT panasonic.net/id/pidsx/global Continuously check invisible

More information

Multi Channel Pressure Sensor Controller PSE200

Multi Channel Pressure Sensor Controller PSE200 PRODUCT NAME Multi Channel Pressure Sensor Controller MODEL / Series / Product Number PSE200 Table of Contents Safety Instructions 2 Model Indication and How to Order 8 Summary of Product parts 9 Definition

More information

Emerson Network Power provides customers with technical support. Users may contact the nearest Emerson local sales office or service center.

Emerson Network Power provides customers with technical support. Users may contact the nearest Emerson local sales office or service center. Liebert PSA iton User Manual Version: V2.8 Revision date: November 14, 2005 Emerson Network Power provides customers with technical support. Users may contact the nearest Emerson local sales office or

More information

Ethernet ITV Modbus TCP

Ethernet ITV Modbus TCP IN19850 PRODUCT NAME Ethernet ITV Modbus TCP MODEL / Series / Product Number ITVXXXX-SMB-XX-DUQ00833-XXXX - 1 - Contents 1. Safety Instructions...- 4-2. About this Manual...- 9-2.1. Purpose...- 9-3. Terminology...

More information

Digital Pressure Switch

Digital Pressure Switch PRODUCT NAME Digital Pressure Switch MODEL / Series / Product Number ZSE20(F) ISE20 Table of Contents Safety Instructions 2 Model Indication and How to Order 8 Summary of Product parts 10 Definition and

More information

HITACHI. EH-150 series PLC EH-RTD8 Resistance Temperature Detective input module Instruction manual. Safety precautions

HITACHI. EH-150 series PLC EH-RTD8 Resistance Temperature Detective input module Instruction manual. Safety precautions HITACHI EH-150 series PLC Resistance Temperature Detective input module Instruction manual Thank you for purchasing a Hitachi Programmable Logic Controller. To operate it safely, please read this instruction

More information

NJ-Series Power Supply Unit NJ-PA/PD

NJ-Series Power Supply Unit NJ-PA/PD NJ-Series Power Supply Unit CSM_NJ-PA_PD_DS_E_1_2 Powerful power supply unit to supply stable power to the NJ-series controller. Stable power supply is available from the NJ-series CPU Unit to each I/O

More information

Line Interactive 1000VA/1400VA/2000VA Uninterruptible Power System

Line Interactive 1000VA/1400VA/2000VA Uninterruptible Power System USER MANUAL Line Interactive 1000VA/1400VA/2000VA Uninterruptible Power System 614-06762-00 IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS This manual contains important instructions for Line Interactive

More information

Doc. no. LEC-OM PRODUCT NAME Programless controller (with stroke study) Step motor (servo 24 VDC ) MODEL/ Series LECP2 Series

Doc. no. LEC-OM PRODUCT NAME Programless controller (with stroke study) Step motor (servo 24 VDC ) MODEL/ Series LECP2 Series Doc. no. LEC-OM06502 PRODUCT NAME Programless controller (with stroke study) Step motor (servo 24 VDC ) MODEL/ Series LECP2 Series Contents 1. Safety Instructions... 4 2. Outlines of Product... 6 2.1 Features...6

More information

SoniChek MC. 99 Washington Street Melrose, MA Phone Toll Free TRIPLETT. Mini Sound Level Meter C Weighted

SoniChek MC. 99 Washington Street Melrose, MA Phone Toll Free TRIPLETT. Mini Sound Level Meter C Weighted 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 TRIPLETT SoniChek MC Mini Sound Level Meter C Weighted Instruction Manual 84-888 4-10 Visit us at www. I. Safety information

More information

Doc. no.lec-om PRODUCT NAME Programless controller Step motor (servo 24 VDC ) MODEL/ Series LECP1 Series

Doc. no.lec-om PRODUCT NAME Programless controller Step motor (servo 24 VDC ) MODEL/ Series LECP1 Series Doc. no.lec-om03902 PRODUCT NAME Programless controller Step motor (servo 24 VDC ) MODEL/ Series LECP1 Series Contents 2. Outlines of Product... 5 2.1 Features... 5 2.2 How to Order... 6 2.3 Structure

More information

TPE 1464 Series Pressure Transducer

TPE 1464 Series Pressure Transducer TPE 1464 Series Pressure Transducer Description The KMC TPE 1464 series of pressure transducers incorporate a gauge pressure transmitter featuring low hysteresis, excellent repeatability, and longterm

More information

NPN output. 200 mm. Type Cable length Model Remarks

NPN output. 200 mm. Type Cable length Model Remarks Retroreflective Photomicrosensor with Lens CSM DS_E_5_2 Photomicrosensor with light modulation for reduced external light interference. Easy adjustment and optical axis monitoring with a light indicator.

More information

Handheld Reader Writer

Handheld Reader Writer Handheld Reader Writer CH1D-V2 A Compact Lightweight Easy-to-use Pen-type Reader Writer. Connects directly to a personal computer or PLC via RS-232C. The Reader Writer s protective construction is IP63

More information

SI unit for IO-Link device

SI unit for IO-Link device PRODUCT NAME SI unit for IO-Link device MODEL / Series / Product Number EX260-SIL1-X207 EX260-SIL1-X210 EX260-SIL3-X207 Table of Contents Safety Instructions 2 Model Indication and How to Order 8 Summary

More information

SOLAR POWER METER TM-206. User s Manual HB1TM

SOLAR POWER METER TM-206. User s Manual HB1TM SOLAR POWER METER TM-206 User s Manual HB1TM2060000 CONTENTS 1. FOREWORD Solar meter: a device used to measure solar power. From the moment you buy such a product, your future is not uncertain any more.

More information

Digital Pressure Switch

Digital Pressure Switch PRODUCT NAME Digital Pressure Switch MODEL / Series / Product Number ZSE20A(F) ISE20A Table of Contents Safety Instructions 2 Model Indication and How to Order 8 Summary of Product parts 10 Definition

More information

Primary Injection Test Procedure

Primary Injection Test Procedure S&C IntelliRupter PulseCloser Fault Interrupter Outdoor Distribution (15.5 kv, 27 kv, and 38 kv) Primary Injection Test Procedure Table of Contents Section Page Section Page Introduction Qualified Persons....

More information

H Series PLC. ! : Indicates Compulsion. EH-150 Analog input module EH-AXH8M Instruction manual. Safety precautions DANGER CAUTION COMPULSION

H Series PLC. ! : Indicates Compulsion. EH-150 Analog input module EH-AXH8M Instruction manual. Safety precautions DANGER CAUTION COMPULSION H Series PLC EH-150 Analog input module EH-AXH8M Instruction manual Thank you for purchasing a Hitachi Programmable Logic Controller. To operate it safely, please read this instruction manual and all the

More information

Type MVTT 14 and MVTT 15: Static Digital Time delay relays

Type MVTT 14 and MVTT 15: Static Digital Time delay relays Type MVTT 4 and MVTT 5: Static Digital Time delay relays Features 000/ setting range Time settings easily selected by means of thumbwheel switches Provide time delayed pick-up, or drop-off Compact construction

More information

SI unit for IO-Link device

SI unit for IO-Link device PRODUCT NAME SI unit for IO-Link device MODEL / Series / Product Number EX260-SIL1-X207 EX260-SIL1-X210 EX260-SIL3-X207 Table of Contents Safety Instructions 2 Model Numbers 8 Summary of Product 9 Summary

More information

Conductive Level Controller

Conductive Level Controller Conductive Level Controller 61F-D21T-V1 Ideal for level control for industrial facilities and equipment. Outputs can be set to self-hold at ON or OFF using self-holding circuits. Sensitivity adjustment

More information

Smart Grid Tie Microinverter User Manual

Smart Grid Tie Microinverter User Manual Smart Grid Tie Microinverter User Manual Thanks for choosing Smart Microinverters. Read the following instruction carefully before installation and operating, install and operate as specified by this user

More information

MIYAWAKI ULTRASONIC TESTER PM11 OPERATOR S MANUAL. Be sure to read this manual for safe and proper operation. Store this manual carefully after use.

MIYAWAKI ULTRASONIC TESTER PM11 OPERATOR S MANUAL. Be sure to read this manual for safe and proper operation. Store this manual carefully after use. GB MIYAWAKI ULTRASONIC TESTER PM11 OPERATOR S MANUAL Be sure to read this manual for safe and proper operation. Store this manual carefully after use. TABLE OF CONTENTS TO THE OWNER GB-0-2 1. SYMBOL INDICATION

More information

Pressure Switch CE40. Digital settings available via IR data communication without actually applying pressure to the unit

Pressure Switch CE40. Digital settings available via IR data communication without actually applying pressure to the unit Pressure Switch CE0 NEW IR Communication type Pressure Switch Rev. Fluids/Gasses Utilizing Stainless Diaphragm Utilizes stainless steel diaphragm for use with a wide variety of pressure media Excellent

More information

Output configuration Contact form Operation indicator Cable length Model PNP open collector. 1 m D5F-2B10 (+ common) ON when operated

Output configuration Contact form Operation indicator Cable length Model PNP open collector. 1 m D5F-2B10 (+ common) ON when operated High-precision Optical Switch D5F CSM_D5F_DS_E_2_2 Optical System Achieves 1-μm Operating Position Repeatability in this 4-way Switch No-contact structure for high reliability. Ceramic materials in measuring

More information

D2VW. Sealed Miniature Basic Switch. Ordering Information Model Number Legend D2VW- -

D2VW. Sealed Miniature Basic Switch. Ordering Information Model Number Legend D2VW- - Sealed Miniature Basic Switch Sealed Miniature Basic Switch Conforms to IP67 (Molded Lead Wire Type Only) Use of epoxy resin assures stable sealing, making this switch ideal for places subject to water

More information

GENERAL PRECAUTIONS GENERAL DESCRIPTION... 6

GENERAL PRECAUTIONS GENERAL DESCRIPTION... 6 Cat.No I173E-EN-01 RX Inverter Expansion I/O Board 3G3AX-EIO21-ROE USER S MANUAL GENERAL PRECAUTIONS... 3 1 GENERAL DESCRIPTION... 6 2 INSTALLATION PROCEDURE... 7 2.1 INSTALLING THE EXPANSION I/O BOARD...

More information

BatteryCheck USER MANUAL BATTERY MANAGEMENT TECHNOLOGY THAT POWERS YOUR ADVENTURES.

BatteryCheck USER MANUAL BATTERY MANAGEMENT TECHNOLOGY THAT POWERS YOUR ADVENTURES. BatteryCheck USER MANUAL BM PRO - 19 Henderson Road, Knoxfield 3180, Victoria, Australia Phone +61 3 9763 0962 Fax +61 3 9763 8789 Email sales@teambmpro.com Web www.teambmpro.com BATTERY MANAGEMENT TECHNOLOGY

More information

3-step setting 2. 2-Color Display High-Precision Digital Pressure Switch. ZSE30A(F)/ISE30A Series. Added vacuum range.

3-step setting 2. 2-Color Display High-Precision Digital Pressure Switch. ZSE30A(F)/ISE30A Series. Added vacuum range. 2-Color Display High-Precision Digital Pressure Switch ZSE3A(F)/E3A Series RoHS Can copy to up to 1 switches simultaneously. setting labor Minimizing ZSE3 E3 ZSE4 E4 The settings of the master sensor can

More information

PRODUCT SPECIFICATION. PC Board Relays. Series.

PRODUCT SPECIFICATION. PC Board Relays. Series. PRODUCT SPECIFICATION PC Board Relays 26 Series www.wernerelektrik.com Technical Data... Specifications...2 Model Number Structure - Relays...3 Model Number Selection...4 Dimensions... 5-6 Accessories...7

More information

Supporting Supplement Manual

Supporting Supplement Manual YAMAHA ROBOT CONTROLLER Supporting Supplement Manual ENGLISH E E72-Ver. 1.03 MEMO INTRODUCTION Thank you for purchasing the YAMAHA ERCX/SRCX/DRCX series robot controller. This supplement manual describes

More information

Line filter SINAMICS. SINAMICS G130 Line filter. Safety information 1. General 2. Mechanical installation 3. Electrical installation 4

Line filter SINAMICS. SINAMICS G130 Line filter. Safety information 1. General 2. Mechanical installation 3. Electrical installation 4 Safety information 1 General 2 SINAMICS SINAMICS G130 Mechanical installation 3 Electrical installation 4 Technical specifications 5 Operating Instructions Control version V4.8 07/2016 A5E00331460A Legal

More information

LXEM145 SERIES Lanx Australis single Phase KWh Meter 45Amp. User manual

LXEM145 SERIES Lanx Australis single Phase KWh Meter 45Amp. User manual LXEM145 SERIES Lanx Australis single Phase KWh Meter 45Amp Single phase two wire DIN rail energy meter (One module) 1.1 Safety instruction 1.2 Foreword 1.3 Performance criteria 1.4 Specifications 1.5 Basic

More information

Additional Explanation for A851GOT Graphic Operation Terminal

Additional Explanation for A851GOT Graphic Operation Terminal Additional Explanation for A851GOT Graphic Operation Terminal GRAPHIC OPERATION TERMINAL Mitsubishi Graphic Operation Terminal SAFETY PRECAUTIONS (Always read these instructions before using this equipment.)

More information

EtherNet/IP TM Compatible Fieldbus System

EtherNet/IP TM Compatible Fieldbus System PRODUCT NAME EtherNet/IP TM Compatible Fieldbus System MODEL / Series / Product Number EX500-GEN2 EX500-S103 EX500-DXP# Table of Contents Safety Instructions 3 Product Overview 9 System construction 9

More information

Option 2. Nil. Note 1) Option 1. Note With waterproof seal and mounting screw. With waterproof seal and mounting screw. 48 conversion adapter

Option 2. Nil. Note 1) Option 1. Note With waterproof seal and mounting screw. With waterproof seal and mounting screw. 48 conversion adapter Series 0-PSE00 RoHS Remote Type Multi-Channel Digital Pressure Sensor Controller How to Order Clean series 0 PSE0 0 M Input/Output specifications 0 NPN 5 outputs + Auto shift input PNP 5 outputs + Auto

More information

SDM120 SERIES. SDM120 series User Manual. Single phase two wire DIN rail energy meter (One module)

SDM120 SERIES. SDM120 series User Manual. Single phase two wire DIN rail energy meter (One module) SDM120 SERIES Single phase two wire DIN rail energy meter (One module) User manual ------------ 1.1 Safety instruction 1.2 Foreword 1.3 Performance criteria 1.4 Specifications 1.5 Basic errors 1.6 Dimension

More information

Making Hazardous Operations Safe and Productive

Making Hazardous Operations Safe and Productive NEW Safety Guard Switching Unit G9SX-GS Making Hazardous Operations Safe and Productive Making Hazardous Operations Safe and Productive This new addition to the model of Flexible Safety Unit G9SX series

More information

DM-918 OPERATIONS MANUAL AUTORANGING MULTIMETER

DM-918 OPERATIONS MANUAL AUTORANGING MULTIMETER DM-918 OPERATIONS MANUAL AUTORANGING MULTIMETER SAFETY INFORMATION The following safety information must be observed to ensure maximum personal safety during the operation of this meter: This meter is

More information

Differential Liquid/Gas Pressure Transmitter

Differential Liquid/Gas Pressure Transmitter Installation Instruction Differential Liquid/Gas Pressure Transmitter Catalog Number(s) 1414-CPZ10FWFAA, 1414-IPZ10FWFAA Explosion Hazard WARNING Do not use in an explosive or hazardous environment, with

More information

Model P4017 Single Channel USB Oscilloscope. Quick Start Guide

Model P4017 Single Channel USB Oscilloscope. Quick Start Guide Model P4017 Single Channel USB Oscilloscope Quick Start Guide General Warranty BNC warrants that the product will be free from defects in materials and workmanship for 3 years from the date of purchase

More information

Instruction book IQAN-LST. Publ no HY /UK Edition 0301

Instruction book IQAN-LST. Publ no HY /UK Edition 0301 Instruction book IQAN-LST Publ no HY17-8364/UK Edition 0301 Contents 1 Introduction......................................................2 2 Precautions.......................................................3

More information

Instruction Manual MINI CALIBRATOR MC-20

Instruction Manual MINI CALIBRATOR MC-20 Instruction Manual MINI CALIBRATOR MC-20 Introduction Thank you for purchasing the MINI CALIBRATOR MC-20. This manual contains operating, specifications and cautions, etc. Please ensure that you fully

More information

Model NPN output PNP output Standard. configuration

Model NPN output PNP output Standard. configuration Slot-type Photomicrosensor (Non-modulated) *1 EE-SX4/6 CSM_EE-SX4_6_DS_E 1 Global Standard Slot-type photomicrosensors with 0- to 100-mA direct switching capacity. Series includes models that enable switching

More information

22-60VDC Grid Tie Microinverter User Manual

22-60VDC Grid Tie Microinverter User Manual 22-60VDC Grid Tie Microinverter User Manual Thanks for using Smart Grid Tie Microinverters. Read the following instruction carefully before installation and operating, install and operate as specified

More information

EM-F-7G Safety Extension Module

EM-F-7G Safety Extension Module EM-F-7G Safety Extension Module One-channel control with four safety output channels Features Safety Extension Module provides additional safety outputs for a Primary Safety Device (for example, an E-stop

More information

SAVE THESE INSTRUCTIONS

SAVE THESE INSTRUCTIONS READ AND FOLLOW ALL SAFETY INSTRUCTIONS! SAVE THESE INSTRUCTIONS AND DELIVER TO OWNER AFTER INSTALLATION IMPORTANT SAFEGUARDS! When using electrical equipment, basic safety precautions should always be

More information

No.EX##-OMN0028. Fieldbus system PROFIBUS DP compatible SI unit PRODUCT NAME. EX600-SPR#A EX600-ED# MODEL/ Series

No.EX##-OMN0028. Fieldbus system PROFIBUS DP compatible SI unit PRODUCT NAME. EX600-SPR#A EX600-ED# MODEL/ Series Fieldbus system PROFIBUS DP compatible SI unit PRODUCT NAME EX600-SPR#A EX600-ED# MODEL/ Series Table of Contents Safety Instructions 3 System Outline 9 Definition and terminology 10 Assembly 12 Mounting

More information

User Manual AIMB-C200. Economical Embedded Chassis for Mini-ITX Motherboard

User Manual AIMB-C200. Economical Embedded Chassis for Mini-ITX Motherboard User Manual AIMB-C200 Economical Embedded Chassis for Mini-ITX Motherboard Copyright The documentation and the software included with this product are copyrighted 2010 by Advantech Co., Ltd. All rights

More information

No.EX##-OMN0036. Fieldbus system Digital unit PRODUCT NAME. EX600-DX## EX600-DY## EX600-DM## MODEL/ Series

No.EX##-OMN0036. Fieldbus system Digital unit PRODUCT NAME. EX600-DX## EX600-DY## EX600-DM## MODEL/ Series Fieldbus system Digital unit PRODUCT NAME EX600-DX## EX600-DY## EX600-DM## MODEL/ Series Table of Contents Safety Instructions 3 System Outline 9 Assembly 10 Mounting and Installation 12 Installation 12

More information

Model VC-SHIELD Shield Box

Model VC-SHIELD Shield Box User s Manual Model 733062 VC-SHIELD Shield Box Yokogawa Electric Corporation IM 733062-01E 2nd Edition Introduction Thank you for purchasing the 733062 VC-SHIELD Shield Box. This user s manual contains

More information

User Manual IDS-3206 Series. 6.5" Industrial Panel Mount Monitor

User Manual IDS-3206 Series. 6.5 Industrial Panel Mount Monitor User Manual IDS-3206 Series 6.5" Industrial Panel Mount Monitor Copyright The documentation and the software included with this product are copyrighted 2014 by Advantech Co., Ltd. All rights are reserved.

More information

Installation and Maintenance Instructions for GC55 Differential Pressure Transducer Version 1.0 5/11

Installation and Maintenance Instructions for GC55 Differential Pressure Transducer Version 1.0 5/11 Installation and Maintenance Instructions for GC55 Differential Pressure Transducer Version 1.0 5/11 2011 Ashcroft Inc. 250 East Main Street, Stratford, CT 06614 USA Tel: 203-378-8281, Fax: 203-385-0402

More information

Operation Manual. Fieldbus system EX510-GDN1. DeviceNet Compatible GW unit

Operation Manual. Fieldbus system EX510-GDN1. DeviceNet Compatible GW unit Fieldbus system DeviceNet Compatible GW unit Operation Manual EX50-GDN URL http://www.smcworld.com Akihabara UDX 5F, --, Sotokanda, Chiyoda-ku, Tokyo 0-00, JAPAN Phone: +8-507-89 Fax: +8-598-56 Note: Specifications

More information

EC Series. Safety Guide

EC Series. Safety Guide EC Series Safety Guide R5906018/02 01/07/2017 Barco Inc, Image Processing 3078 Prospect Park Drive, Rancho Cordova, CA, 95670, USA Phone: +1 916 859-2500 Fax: +1 916 859-2515 Support: www.barco.com/en/support

More information

MT1810A 4 Slot Chassis Operation Manual

MT1810A 4 Slot Chassis Operation Manual MT1810A 4 Slot Chassis Operation Manual Seventh Edition For safety and warning information, please read this manual before attempting to use the equipment. Additional safety and warning information is

More information

E2K-F. Flat Capacitive Sensor with a Thickness of Only 10 mm. Flat Proximity Sensor. Ordering Information. Sensors [Refer to Dimensions on page 4.

E2K-F. Flat Capacitive Sensor with a Thickness of Only 10 mm. Flat Proximity Sensor. Ordering Information. Sensors [Refer to Dimensions on page 4. Flat Proximity Sensor EK-F CSM_EK-F_DS_E Flat Capacitive Sensor with a Thickness of Only mm Flat Sensor with excellent space efficiency. (Model with built-in Amplifier is only mm thick.) Direct mounting

More information

Model Number Structure

Model Number Structure Total Counter/Time Counter (DIN 8 x ) CSM DS_E DIN 8 x -mm Total Counter/Time Counter with Easy-to-read Displays and Water and Oil Resistance Equivalent to IP66 High-visibility, negative transmissive LCD

More information

No.EX##-OMN0034. Fieldbus system CC-Link compatible SI unit PRODUCT NAME. EX600-SMJ# EX600-ED# MODEL/ Series

No.EX##-OMN0034. Fieldbus system CC-Link compatible SI unit PRODUCT NAME. EX600-SMJ# EX600-ED# MODEL/ Series Fieldbus system CC-Link compatible SI unit PRODUCT NAME EX600-SMJ# EX600-ED# MODEL/ Series Table of Contents Safety Instructions 2 System Outline 8 Definition and terminology 9 Assembly 11 Basic precautions

More information

No.EX##-OMN0030-A. Fieldbus system DeviceNet TM compatible SI unit PRODUCT NAME. EX600-SDN#A EX600-ED# MODEL/ Series

No.EX##-OMN0030-A. Fieldbus system DeviceNet TM compatible SI unit PRODUCT NAME. EX600-SDN#A EX600-ED# MODEL/ Series Fieldbus system DeviceNet TM compatible SI unit PRODUCT NAME EX600-SDN#A EX600-ED# MODEL/ Series Table of Contents Safety Instructions 3 System Outline 9 Definition and terminology 10 Assembly 12 Mounting

More information

SIRIUS CAPACITOR MODULE User Manual. Model number: A-1.7C-M-SD-G Version 1.0; Release Date: April 2018

SIRIUS CAPACITOR MODULE User Manual. Model number: A-1.7C-M-SD-G Version 1.0; Release Date: April 2018 SIRIUS CAPACITOR MODULE User Manual Model number: 3550-48-A-1.7C-M-SD-G Version 1.0; Release Date: April 2018 Introduction The Sirius Capacitor Module ( Sirius ) is supercapacitor-based storage that uses

More information

SUN2000P-375 W Smart PV Optimizer. User Manual. Issue 01. Date HUAWEI TECHNOLOGIES CO., LTD.

SUN2000P-375 W Smart PV Optimizer. User Manual. Issue 01. Date HUAWEI TECHNOLOGIES CO., LTD. Issue 01 Date 2017-08-01 HUAWEI TECHNOLOGIES CO., LTD. 2017. All rights reserved. No part of this document may be reproduced or transmitted in any form or by any means without prior written consent of

More information

User Manual IDS-3106 Series. 6.5" Industrial Open Frame Monitor

User Manual IDS-3106 Series. 6.5 Industrial Open Frame Monitor User Manual IDS-3106 Series 6.5" Industrial Open Frame Monitor Copyright The documentation and the software included with this product are copyrighted 2014 by Advantech Co., Ltd. All rights are reserved.

More information

Remote access to status, test and reset functions. Built-in diagnostic indicators. Options Lid-mounted reset key switch (MC4)

Remote access to status, test and reset functions. Built-in diagnostic indicators. Options Lid-mounted reset key switch (MC4) File no. LR90200 Description mats and edges MC3, MC4 and Safety Mat Controllers Both metal enclosure and DINrail mount models available Control reliable Remote access to status, test and reset functions

More information

Model Number Structure

Model Number Structure Digital Panel Meter CSM DS_E_2_1 Easy-to-use, w-cost Digital Panel Meter that Accepts AC Input Compact DIN-size (96 x 48 (W x H)) body. Mounting thickness of only 3.5 mm required. ghly visible display

More information

Operation Manual. Fieldbus system EX510-GPR1. PROFIBUS DP Compatible GW unit

Operation Manual. Fieldbus system EX510-GPR1. PROFIBUS DP Compatible GW unit Fieldbus system PROFIBUS DP Compatible GW unit Operation Manual EX50-GPR URL http://www.smcworld.com Akihabara UDX 5F, --, Sotokanda, Chiyoda-ku, Tokyo 0-00, JAPAN Phone: +8 3-507-89 Fax: +8 3-598-536

More information

INSTRUCTION MANUAL TRIP CIRCUIT SUPERVISION RELAY GKAD1

INSTRUCTION MANUAL TRIP CIRCUIT SUPERVISION RELAY GKAD1 INSTRUCTION MANUAL TRIP CIRCUIT SUPERVISION RELAY GKAD1 TOSHIBA Corporation 2004 All Rights Reserved. ( Ver. 1.6 ) Safety Precautions Before using this product, please read this chapter carefully. This

More information

D5B. Detects Objects in Multiple Directions with High Sensitivity, Ideal for Robotics. Mechanical Touch Switch. Model Number Structure

D5B. Detects Objects in Multiple Directions with High Sensitivity, Ideal for Robotics. Mechanical Touch Switch. Model Number Structure Mechanical Touch Switch D5B CSM_D5B_DS_E_3_2 Detects Objects in Multiple Directions with High Sensitivity, Ideal for Robotics Slow-action switching mechanism used. Gold-plated contact with coil spring

More information

Suitable for detecting transparent films or transparent bottles

Suitable for detecting transparent films or transparent bottles Ultrasonic Sensor Suitable for detecting transparent films or transparent bottles Reliable detection of transparent objects The sensor reliably detects transparent films or transparent objects. Only 16

More information

Precautions. Please read carefully before using this product.

Precautions. Please read carefully before using this product. Thank you for purchasing this BEWITH Mirror Media MM-1. It is designed to give you many years of enjoyment. Please read all instructions in this manual before attempting operation and keep it handy for

More information

Thank you for purchasing the CHP Assembly Tool. In order to ensure maximum performance and

Thank you for purchasing the CHP Assembly Tool. In order to ensure maximum performance and Power Supply Instruction Manual Applicable Models: APS-301A, APS-351B, APM-301A, APM-301C Thank you for purchasing the CHP Assembly Tool. In order to ensure maximum performance and product life, please

More information

Operating instructions Enabling switch (handle switch) ZSD5 ZSD6. 1. About this document. Content. 7 Appendix 7.1 Wiring example...

Operating instructions Enabling switch (handle switch) ZSD5 ZSD6. 1. About this document. Content. 7 Appendix 7.1 Wiring example... 7 ppendix 7.1 Wiring example...5 8 Declaration of conformity 8.1 EC Declaration of conformity...6 Operating instructions.............pages 1 to 6 Translation of the original operating instructions x.000

More information

SS Series Compatible Mounting with a Simple Construction and Easy-to-Use Design Concept

SS Series Compatible Mounting with a Simple Construction and Easy-to-Use Design Concept Subminiature Basic Switch SS Series Compatible Mounting with a Simple Construction and Easy-to-Use Design Concept One-piece terminal construction to keep out flux. A single leaf movable spring construction.

More information

External level devices for conductive point level switch

External level devices for conductive point level switch SENSORS FOR FOOD AND BIOPHARMA. Product Information VNV-2, ZNV-2 CONTROLS External level devices for conductive point level switch Application/Specified usage Point level detection of aqueous, conductive

More information

GREISINGER electronic GmbH D Regenstauf, Hans-Sachs-Straße 26

GREISINGER electronic GmbH D Regenstauf, Hans-Sachs-Straße 26 E39.0.31.6C-02 Data logger for humidity temperature as of version V1.0 Operating Manual T-Logg 160 GREISINGER electronic GmbH D - 93128 Regenstauf, Hans-Sachs-Straße 26 +49 (0) 9402 / 9383-0 +49 (0) 9402

More information

Instruction book IQAN-LSL. Publ no HY /UK Edition 0301

Instruction book IQAN-LSL. Publ no HY /UK Edition 0301 Instruction book IQAN-LSL Publ no HY17-8367/UK Edition 0301 Contents 1 Introduction......................................................2 2 Precautions.......................................................3

More information

Ultra Slim Relays 24

Ultra Slim Relays 24 Ultra Slim Relays 24 Technical Data... 1 Specifications.2 Model Number Structure - Relays...3 Model Number Selection...4 Accessories...5 Safety Precautions...6 Ultra Slim Relays WERNER`s embody the latest

More information

Timers NEW DESIGN! RTE Series. RTE Series Analog Timers

Timers NEW DESIGN! RTE Series. RTE Series Analog Timers RE Series imers RE Series Analog imers NEW DESIN! Key features of the RE series include: 0 time ranges and 0 timing functions ime delays up to 600 hours Space-saving package High repeat accuracy of ± 0.%

More information