Desigo RXA Room controllers without bus communications Range overview. CA2S3880en_ Building Technologies
|
|
- Dwight Lamb
- 6 years ago
- Views:
Transcription
1 s Desigo RXA Room controllers without bus communications Range overview CA2S3880en_ Building Technologies
2 Desigo TM RXA Room controllers without bus communications Contents Desigo RXA Range overview... 4 Applications... 7 Installation... 8 Desigo TM RXA equipment overview (including field devices)
3 Desigo RXA Room controllers without bus communications TM Desigo RXA is a range of individual room controllers for fan-coil systems. It ensures individual demand-based comfort for the occupants of public buildings, offices, schools, hotels, etc. TM A sense of well-being and comfort in every room Most people in the industrial world spend some 90 % of their time indoors. About one third of this time is spent at work. In this context it is clear that good indoor air quality, the right temperature and draught-free air renewal are vital prerequisites for a sense of well-being and motivation. In offices, public buildings and hotels, the indoor air is often conditioned with fan-coil units. The Desigo RXA range includes all the necessary control equipment for applications of this kind. The following options are available, depending on the application software: - Two-pipe system with change-over - Four-pipe system - Electric heating and water-based cooling - With or without fan speed control - Thermic or motorized valves - Limit control of the injected air - Fan-coil unit with outside air damper 3
4 Range overview Raumkontroller Desigo TM RXA the innovative room control range The Desigo TM RXA hardware The range comprises the compact room controllers, Desigo RXA20.1, RXA21.1, RXA22.1 and RXA29.1. The input/output configuration and mounting options of these controllers make them ideal for fan coil applications. They can be installed in the fan coil unit, in control panels or on ducting. In conjunction with the available application software, they can also be used for radiator-type applications. The HVAC functions can be operated with standard room units. The Desigo TM RXA software Each Desigo RXA controller is loaded with application software for a variety of applications. Each application includes a range of control and interlock programs. The required application is selected by means of programming switches on the room controller. The Desigo RXA controller then controls comfort conditions in rooms and enclosed zones on the basis of the selected application. Each room or zone can be operated in accordance with specific requirements. The result is optimum comfort using the minimum of energy. Radiators HVAC Fan coils QAX QAX91.1 RXA20.1/FC-01 RXA21.1/FC-02 RXA22.1/FC-03 RXA29.1/FC-04 4
5 Range overview Inputs and outputs The input and output functions are determined by the application software and the associated parameter settings. For example, the AC 24 V outputs can be configured for thermic valve actuators or for 3-position actuators (see table). Connections and functions RXA.20.1 RXA.21.1 RXA22.1 RXA.29.1 Supply voltage AC 230 V AC 230 V AC 230 V AC 230 V Interface for standard room unit (PPS2) - Digital inputs 1) Analog inputs for L&S Ni1000 temperature sensor or setpoint adjuster AC 24 V outputs 2) Volt-free relay outputs for fan Volt-free relay output for electric reheater Room temperature setpoint adjustment 1) For window switches, occupancy sensors, time switch, thermostats (changeover) 2) For control of 2-position actuators (e.g. thermic valves with a PWM algorithm) or 3-position motorized actuators 5
6 Range overview The room unit the key to indoor comfort and well-being. Individual operation at room level The Desigo RXA range of room units is designed to fulfil a wide range of different user requirements. When designing these stylish room units, the designers also placed special emphasis on ergonomic factors. The standard QAX QAX39.1 room units are available as one option for the HVAC applications. They are connected to the Desigo RXA controller via a special interface. Alternatively, the system can be operated with conventional HVAC room units. Functions of the room units with a PPS2 interface QAX30.1 QAX31.1 QAX32.1 QAX33.1 QAX84.1 QAX34.1/ PPS2 QAX39.1 QAX90.1 QAX91.1 Built-in room temperature sensor Room temperature setpoint adjustment Selection of operating mode ( /Auto) 1) Selection of operating mode ( /Auto) 1) and fan speed LCD display for room temperature, operating mode and fan speed PPS2 interface to Desigo RXA controller 2) 1) Operating mode Auto: Comfort mode : Standby or Economy mode 2) The PPS2 interface for wireless room units QAX90.1 and QAX91.1 is the RXZ91.1 receiver Functions of room units without a PPS2 interface QAA24 QAA27 BSB25.1 Built-in room temperature sensor Room temperature setpoint adjustment 6
7 Applications D3 YH A number of applications are permanently stored in the Desigo RXA room controllers before they leave the factory. The programming switches on the room controller are then used to define the application actually required and to set the associated parameters. Q1 T B1 D1.2 T R1 D1.1 D2 N1 The following applications are available: RXA room controller 20.1 FC FC FC FC-04 FNC02 Two-pipe system with change-over X X X FNC03 Two-pipe system with change-over and electric re-heater X FNC04 Four-pipe system X X X FNC05 Four-pipe system with electric re-heater X FNC08 Four-pipe system with supply air temperature limit control X X FNC10 Two-pipe system with change-over and outside air damper X X X FNC12 Four-pipe system with outside air damper X X FNC18 Two-pipe system (cooling) and radiator-type heating X X X FNC20 Four-pipe system with one damper X X X 7
8 Installation The Desigo RXA controllers are designed to be installed in a various ways: In fan coil units (mounted with screws or on DIN rails) In control panels (on DIN rail) In ceiling voids Under floors In sill or floor ducting Various options for installation If the controllers are mounted outside control panels or fan coil units, terminal covers are required Example: RXA20.1 with terminal covers 8
9 Desigo TM RXA equipment overview (including field devices) Desigo RXA controllers RXA20.1, RXA21.1, RXA22.1 Room controllers for fan-coil units, with PPS2 room unit interface Documentation CA2N8681 RXA29.1 Room controller for fan-coil units, without PPS2 room unit interface CA2N8682 Desigo RX room operation (via PPS2) QAX30.1 Room unit with temperature sensor CA2N1741 QAX31.1 Room unit with temperature sensor and setpoint adjustment CA2N1741 QAX32.1 Room unit with temperature sensor, setpoint adjuster and /Auto switch CA2N1641 QAX33.1 Room unit with temperature sensor, setpoint adjustment and /Auto/Fan switch QAX34.1 Room unit with temperature sensor, setpoint adjustment, /Auto/Fan switch and LCD CA2N1642 CA2N1645 QAX39.1 Universal setpoint adjuster CA2N1646 QAX84.1/PPS2 Flush-mounting room unit with temperature sensor, setpoint adjustment, /Auto/Fan switch and LCD CA2N1649 QAX90.1 Wireless room unit with temperature sensor CA2N1643 QAX91.1 Wireless room unit with temperature sensor and setpoint adjuster CA2N1643 RXZ90.1 Receiver with PPS2 interface, for wireless room units CA2N1644 Desigo RXA conventional room operation without PPS2 interface QAM22 Duct temperature sensor CM1N1771 QAP22... Cable temperature sensor CM1N1831 QAA24 Room temperature sensor CM1N1721 QAA27 Room temperature sensor with setpoint adjuster CM1N1721 BSG21.5 Universal setpoint adjuster CE1N1991 9
10 Equipment overview AC 24 V valve actuators Documentation 2-position, thermic See Desigo RX Hardware overview CA2N position, motorized Damper actuators See Desigo RX Hardware overview CA2N3804 Accessories RXZ20.1 Terminal covers for RXA20.1, RXA21.1 and RXA22.1 CA2N3834 SEA41.2 Current valve, AC 24 V, AC 24 V PWM, kw CM1N4936 UA1T Power amplifier for thermic valve actuators CA2N3591 RKN-S Setpoint reset module (not available any more) CA2N3389 Desigo RXA, other documentation Desigo RXA Technical manual (including application software) Desigo RXA Installation guide CA2Z3889 CA2Z3884 Siemens Switzerland Ltd Infrastructure & Cities Sector Building Technologies Division International Headquarters Gubelstrasse 22 CH-6301 Zug Tel Fax Siemens Switzerland Ltd. Subject to change 10
Building Technologies. Desigo RXC Room automation system System description. Version 5 and later
Building Technologies Desigo RXC Room automation system System description Version 5 and later Contents Comfort and well-being in every room... 4 Range overview... 5 The room controllers... 6 The room
More informationDESIGO RXC The individual room management system Range description CA2S3801E Siemens Building Technologies Building Automation
DESIGO RXC The individual room management system Range description CA2S3801E 02.2002 Siemens Building Technologies Building Automation DESIGO TM RXC The individual room management system Contents DESIGO
More informationDESIGO RX Individual room controllers. for fan-coil systems, chilled ceilings and radiators, with LONMARK-compatible bus communications
3 834 DESIO RX Individual room controllers for fan-coil systems, chilled ceilings and radiators, with MARK-compatible bus communications RXC20.1 RXC21.1 The RXC20.1 and RXC21.1 controllers are used for
More informationNon-communicating room controllers
3 882 DESIGO RXA Non-communicating room controllers RXA29.1 For fan-coil systems The RXA29.1 room controller are used for temperature control in individual rooms. For 2-pipe or 4-pipe fan-coil systems,
More informationRoom unit with PPS2 interface
s 1 640 1640P01 Desigo RX Room unit with PPS2 interface For use with: QAX34.3 Equipment from the RXC, RXB, RXL and RXA (PPS2) ranges Desigo PX automation stations 1) Devices with a PPS2 interface Measurement
More informationNon-communicating room controllers
3 881 DESIO RXA on-communicating room controllers For fan-coil systems RXA20.1 RXA21.1 RXA22.1 The RXA20.1, RXA21.1 and RXA22.1 room controllers are used for temperature control in individual rooms. For
More information1 Contents. Selection guide RXC, RXB, RXL, RXA. System overview DESIGO RXB. Hardware overview DESIGO RX
DESIGO RXB (KNX) Technical manual Version 2.37 and higher 2 1 Contents Selection guide RXC, RXB, RXL, RXA 3 System overview DESIGO RXB 4 5 6 7 Hardware overview DESIGO RX Data sheets RXB (KNX) Room controllers,
More informationRXL21.1 RXL22.1. Room controllers RXL. Communicating controllers for fan-coil applications FC-10, FC-11, FC12
3 877 3877P0 RXL Room controllers Communicating controllers for fan-coil applications FC-0, FC-, FC2 RXL2. RXL22. The RXL2. and RXL22. room controllers are used for temperature control in individual rooms.
More informationTemperature controller Ducted systems
2 725 Temperature controller Ducted systems Standard model without zoning functions RRV851 Multifunctional controller used for central control of ducted HVAC systems in combination with a QAX850 master
More informationRXL24.1. Room controller RXL. Communicating controller for chilled ceiling and radiator applications CC-02
s 3 878 RXL Room controller RXL24.1 Communicating controller for chilled ceiling and radiator applications CC-02 The RXL24.1 room controller is used for temperature control in individual rooms. For chilled
More informationRoom unit with PPS2 interface
1 642 Desigo RX Room unit with PPS2 interface for use with: QAX33.1 devices of the ranges Desigo RXC, RXB, RXL, and RXA (PPS2) Desigo PX Automation stations 1) devices with a PPS2 interface Room temperature
More informationRXL24.1. Room controller RXL. Communicating controller for chilled ceiling and radiator applications CC-02
s 3 878 RXL Room controller RXL24.1 Communicating controller for chilled ceiling and radiator applications CC-02 The RXL24.1 room controller is used for temperature control in individual rooms. For chilled
More informationRXC39.5. Room controller. Building Technologies. Desigo RXC. Communicating room controller for fan-coil applications
s 3 856 Desigo RXC Room controller RXC39.5 Communicating room controller for fan-coil applications The RXC39.5 room controller is used for temperature control in individual rooms. For fan-coil systems
More informationTemperature controller Multi-zone ducted systems
2 727 emperature controller ulti-zone ducted systems ulti-zone model with up to six zone outputs RRV856 ultifunctional controller used for central control of ducted HVAC systems in combination with QAX850
More informationRXB39.1. Room controller RXB. Communicating room controller for fan-coil applications FC-13
s 3 875 RXB Room controller Communicating room controller for fan-coil applications FC-13 RXB39.1 The RXB39.1 room controller is used for temperature control in individual rooms. For 2-pipe or 4-pipe fan-coil
More informationQAX50.1 QAX50.5 QAX51.1 QAX51.5. Flexible room unit. Desigo RXC
1 648 Desigo RXC Flexible room unit for integrated operation of HVAC, lighting and blinds in individual rooms; with LONMARK -compatible bus communication QAX50.1 QAX50.5 QAX51.1 QAX51.5 Room temperature
More informationMaster room unit for RRV controllers
2 722 Master room unit for RRV controllers 2 wire bus connection QAX850 Multifunctional, digital room unit for installer and end-user interface with RRV controllers. Use Use Application Room unit in combination
More informationRXB10.1. Room controller. Siemens Building Technologies Building Automation DESIGO RXB. for chilled ceilings and radiators with EIB bus communication
3 870 DESIO RXB Room controller for chilled ceilings and radiators with EIB bus communication RXB10.1 The RXB10.1 controller is used for temperature control in individual rooms: For chilled ceilings and
More informationCONTENTS CONTROLLERS room controllers room units control units PRODUAL 3 CATALOGUE
Catalogue 207 CONTENTS CONTROLLERS... 4 room controllers... 5 room units... 29 control units... 24 PRODUAL 3 CATALOGUE T U R KU I C T C ON T R OL L E R S Multifunctional controllers for optimal performance
More informationRoom unit with PPS2 interface
1 626 Room unit with PPS2 interface for use with: controllers with a PPS2 interface QAA88.3 Room temperature measurement Key buttons for adjustment of the room temperature setpoint Key buttons for operating
More informationSemi flush-mounted room temperature controllers with LCD
s 3 077 RDD310 RDE410 Semi flush-mounted room temperature controllers with LCD For heating systems RDD310 RDE410 RDD310 and RDE410 features: Operating voltage AC 230 V 2-position control with On / Off
More informationSemi Flush-mount Room Temperature Controllers with LCD
3 076 RDF300, RDF300.02, RDF340 RDF400.01 Semi Flush-mount Room Temperature Controllers with LCD for 2-pipe, 2-pipe with el. heater and 4-pipe fan coil units for use with compressors in DX type equipment
More informationFCU-4 FAN COIL CONTROLLER
FCU-4 FAN COIL CONTROLLER BACnet Enabled Description The FCU-4 is designed to provide complete control of fan coil units. The FCU-4 incorporates all the inputs and outputs to ensure that this advanced
More informationTemperature controller for multi-zone ducted systems
2 727 emperature controller for multi-zone ducted systems RRV856 ultifunctional controller used for central control of ducted HVAC systems in combination with QAX850 and QAW850 room units. ulti-zone model
More informationRXL applications library
RXL applications library CLC and RAD description of functions for CC-02 (CLC and RAD applications: see document CM110676). Related documents CM110676 CM1Y9776 CLC and RAD applications from CC-02 RXB /
More informationSuitable for a wide range of installations with wall-mount, flush-mount and hand-held remote control options.
TUC03 Configurable Terminal Unit Controller Product Bulletin The TUC03 Configurable Terminal Unit Controller is designed specifically to provide direct digital control of terminal unit applications with
More informationField selectable application type and room module series, via dip-switches on controller
TUC03 Plus Configurable Terminal Unit Controller Product bulletin The TUC03 Plus configurable Terminal Unit Controller is specifically designed to provide an improved BACnet integration. It allows the
More informationSemi flush-mounted room temperature controllers with LCD
s 3 077 RDD310 RDE410 Semi flush-mounted room temperature controllers with LCD For heating systems RDD310 RDE410 RDD310 and RDE410 features: Operating voltage AC 230 V 2-position control with On / Off
More informationRoom thermostat with KNX communications For VAV heating and cooling systems
s 3 192 Room thermostat with KNX communications For VAV heating and cooling systems RDG400KN KNX bus communications (S-mode and LTE mode) Backlit display PI / P control Output for VAV box / damper: DC
More informationFCU-4 FAN COIL CONTROLLER
FCU-4 FAN COIL CONTROLLER BACnet Enabled Description The FCU-4 is designed to provide complete control of fan coil units. The FCU-4 incorporates all the inputs and outputs to ensure that this advanced
More informationRDF301 RDF CE1N3171en 02 Jun 2010 Building Technologies
s 3 171 RDF301 RDF301.50 Semi flush-mount room thermostats with KNX communications For 2-pipe, 2-pipe with electrical heater, and 4-pipe fan coil units For use with compressors in DX type equipment RDF301
More informationRoom Temperature Controller
3 023 Room Temperature Controller for four-pipe fan coil units RCC30 Outputs for on / off valve actuators Outputs for three-speed fan Control depending on room or return air temperature Operating modes:
More informationRoom thermostats with KNX communications
s 3 192 RDG400KN RDG405KN Room thermostats with KNX communications For VAV heating and cooling systems For room temperature and indoor air quality control RDG400KN RDG405KN KNX bus communications (S- and
More informationControl systems. Efficient room control
Control systems Efficient room control AIRCONTROL Efficient room control with X-AIRCONTROL Humidity Occupancy Increasingly demanding requirements on energy efficiency as well as the latest EU regulations
More informationRoom unit with PPS2 interface
1 641 DESIGO RX Room unit with PPS2 interface for use with: QAX321 devices of the ranges DESIGO RXC, RXB, and RXA (PPS2) DESIGO PX Automation stations 1) devices with a PPS2 interface Room temperature
More informationHeating Circuit Controller
2 705 Synco 900 Heating Circuit Controller RRV912 RF-controlled heating circuit controller for up to 2 heating circuits RF communication based on KNX standard (868 MHz, bidirectional) Connection facility
More informationRoom Temperature Controllers
3 021 Room Temperature Controllers for two-pipe fan coil units RCC10 Output for on / off valve actuator Outputs for three-speed fan Control depending on the room or return air temperature (RCC10) Automatic
More informationTemperature Controller (Heat Pumps)
3 347 Temperature Controller (Heat Pumps) For comfort control in HVAC & R systems Standalone electronic controller Programmable controller with preconfigured applications Three universal inputs for Ni1000,
More informationTemperature Controller
2 728 Temperature Controller ultizone Floor Heating Systems RRV817 ultizone model with up to 7 zone outputs by combining 2 RRV817 controllers. Used for central control of underfloor heating systems in
More informationRoom Temperature Controller
3 023 Room Temperature Controller for four-pipe fan coil units RCC30 Outputs for on / off valve actuators Outputs for three-speed fan Control depending on room or return air temperature Operating modes:
More informationRoom controller STRA-17
Room controller STRA-17 Application example Room 2 Room 3 Room 4 SCADA EXOline alt. RS485 Modbus Transformer STRZ-24 (Required component) STRA-17 is a preprogrammed room controller intended to control
More informationRDF Series Room Temperature Controllers
Document No. 19-49 RDF Series Room Temperature Controllers Product Description Room Temperature Controllers with LCD for twopipe (with and without an electrical heater) and fourpipe fan coil units. Installation
More informationTAC Xenta 121-FC Programmable Fan Coil Application
TAC Vista TAC Xenta 121-FC Programmable Fan Coil Application TAC Xenta 121-FC is an easily programmable controller intended for both 2-pipe and 4-pipe applications, with or without re-heat. It can be configured
More informationRWD32S Software Tool. Operating Instructions. CE1U3344en Building Technologies
RWD32S Software Tool Operating Instructions CE1U3344en 25.06.2009 Building Technologies Siemens Switzerland Ltd Industry Sector Building Technologies Division International Headquarters HVAC Products Gubelstrasse
More informationRVL470. Heating controller. G2522en. Installation Instructions. 1 Installation. 2 Commissioning Wall mounting DIN rail mounting
G2522en Heating controller Installation Instructions RVL470 1 Installation 1.1 Place of installation In a dry room, e.g. the boiler room Mounting choices: In a control panel (on the inner wall or on a
More informationHLS34 Modbus FCU/VAV Controllers installation instructions
HLS34 Modbus FCU/VAV Controllers installation instructions The HLS34 is specifically designed for individual room temperature and zone control applications. The controllers have built-in RS-485 channel
More informationSE7600E Series Application Guide
SE7600E Series Application Guide Schneider Electric SE7600E Series RTU Controller with IAQ Control Application Guide CONTENTS Solution Overview 2 Product Overview 3 Features & Benefits 3 System Overview
More informationUniversal Controller
3 342 Universal Controller For comfort control in HVAC & R-Systems Standalone electronic universal controller with P or PI response Operating voltage in accordance to type AC 24 V Control application selectable
More informationHeating Circuit Controller
2 706 Synco living Heating Circuit Controller RRV918 RF-controlled heating circuit controller for up to 8 heating circuits RF communication based on KNX standard (868 MHz, bidirectional) Connection facility
More informationCommunicative controller for VAV systems
FCR015 Communicative controller for VAV systems Summary FCR015 is a communicative controller for heating and cooling panels and a VAV (variable air volume) damper. It measures temperature and CO 2 concentration
More informationBuilding Control GAMMA instabus
The worldwide standard for home and building control Building Control GAMMA instabus siemens.com/gamma The comprehensive GAMMA instabus product portfolio comprises intelligent devices and is your key to
More informationBuilding Energy Management Training Systems
Building Energy Management Training Systems 3466-00 LabVolt Series Datasheet Festo Didactic en 120 V - 60 Hz 03/2019 Table of Contents General Description 2 Courseware 2 Topic Coverage 2 List of Available
More information24-hour room temperature controller
s 2 201 24-hour room temperature controller Heating applications REV13.. Use Mains-independent, battery-operated room temperature controller featuring user-friendly operation, easy-to-read display and
More informationRoom thermostats with KNX communications
s 3 191 Room thermostats with KNX communications For fan coil unit applications For universal applications For use with compressor in DX type equipment RDG100KN RDG160KN KNX bus communication (S-mode and
More informationExactLogic BACnet Communicating Pressure Dependent VAV Damper Control with Heat EXL01820 Sequence Datasheet
ExactLogic BACnet Communicating Pressure Dependent VAV Damper Control with Heat EXL01820 Sequence Datasheet DataSheet ev 1.12.307/4.0 June 14, 2018 Operating Sequence Standard Occupied During normal occupied
More information7-day room temperature controller
s 2 205 7-day room temperature controller Heating or cooling applications REV24.. Mains-independent, battery-operated room temperature controller featuring user-friendly operation, easy-to-read display
More informationRCF-230CTD. Room controller for fan-coil applications with outputs for two thermal or one 3-position actuator or function for an electric heater
revision 03 2012 RCF-230CTD Room controller for fan-coil applications with outputs for two thermal or one 3-position actuator or function for an electric heater RCF-230CTD is a room controller intended
More informationClimatix Sales Presentation. Kurt Steiner / xxx-x-xxx
Climatix Sales Presentation Siemens Switzerland Ltd 2010 Introduction Climatix HVAC market trends Siemens answer Climatix TM Range Overview Climatix 600 System Topologies and Components Applications and
More informationRCF-230CD. Communicating room thermostat for fan-coil applications with on/off outputs
revision 11 2013 RCF-230CD Communicating room thermostat for fan-coil applications with on/off outputs RCF-230CD intended to control heating and/or cooling in 2- or 4-pipe installations. Setpoint and fan
More information5 year. Controllers for comfortable indoor climate and energy efficiency
Controllers for comfortable indoor climate and energy efficiency Produal controllers are widely used in various commercial and public facilities to implement optimal room climate control. The best possible
More informationHigh-performance switching actuators
High-performance switching actuators Wide-ranging applications efficient installation and set-up operation for many years The worldwide standard for home and building control siemens.com/gamma Switching
More information7-day room temperature controller
s 2 205 7-day room temperature controller Heating or cooling applications REV24.. Use Mains-independent, battery-operated room temperature controller featuring user-friendly operation, easy-to-read display
More informationRoom Temperature Controller with 7-Day Time Switch, LCD and opt. Remote Temperature Sensor
3 036 Room emperature Controller with 7-Day ime Switch, LCD and opt Remote emperature Sensor for heating systems RDE201 2-position control with ON/OFF output for heating Operating modes: normal operation
More informationRXM39.1. PL-Link IO Block. Desigo TRA. Use with PXC3 series room automation station
s 3 836 3836P01 Desigo TRA PL-Link IO Block Use with PXC3 series room automation station RXM39.1 The PL-Link IO Block contains the inputs and outputs controlled by a room automation station via PL-Link.
More informationBACnet Product Overview
BACnet Product Overview Comfort and energy-saving of a HVAC system are all about control. With networking devices, you can monitor and control your equipment via a communication system anywhere and anytime
More informationWall-mounted room thermostats with LCD
s 3 181 RDG100 RDG110 RDG110U RDG100 RDG160 RDG160U Wall-mounted room thermostats with LCD for fan coil unit applications for universal applications for use with compressors in DX-type equipment RDG1..
More informationBACnet PTEC Unit Conditioner/Fan Coil P. Controller. Control Applications. Accessories. Product Description. Warning/Caution Notation
Installation Instructions BACnet PTEC Unit Conditioner/Fan Coil Controller Figure 1. BACnet PTEC Unit Conditioner/Fan Coil Controller. Control Applications 6540, 6541, 6550, 6551, 6552, 6553 and 6554 Product
More informationOEM. Room unit QAA822 with2- wire interface. Building Technologies CLIMATIX TM. For use with Climatix controllers
OEM CLIMATIX TM Room unit QAA822 with2- wire interface For use with Climatix controllers Remote control of air conditioning unit Mandík Measurement of the room temperature Buttons for starting, setting
More informationRoom controller. For chilled ceiling and radiator applications CC-02 with Konnex bus communications (S-mode and LTE mode)
s 3 874 RXB Room controller For chilled ceiling and radiator applications CC-02 with Konnex bus communications (S-mode and TE mode) RXB24.1 The RXB24.1 room controller is used for temperature control in
More informationTracer Controls. Tracer MP501 Controller BAS-PRC008-EN. January 2005
Tracer Controls Tracer MP501 Controller January 2005 BAS-PRC008-EN Introduction The Tracer MP501 controller is a configurable, multi-purpose controller used to provide direct-digital control for heating,
More information75F Smart VAV with Reheat
A unique system-wide approach to maximizing performance PRODUCT OVERVIEW The wireless control solution reduces install cost, improves energy efficiency, and introduces remote control and diagnostic capabilities
More informationUC102 basic version with display and knob UC102BL version with display, knob and backlight UC102DK version without knob and display
UC102 Communicative heating controller Summary UC102 is a communicative room heating controller with two inputs and one PWM output for control of a radiator or electrical heater. It can work autonomously,
More informationTC-9102 Terminal Controller
Metasys Network Sales Resource Manual 635 Application Specific Controllers Section Product Bulletin Issue Date 1095 TC-9102 Terminal Controller The TC-9102 Terminal Controller, the latest addition to the
More informationUniversal Modules. Synco 700. Extension modules for use with controls of the Synco 700 family. Use
s 3 146 Synco 700 Universal Modules RMZ78 Extension modules for use with controls of the Synco 700 family. Use For heating, ventilation, air conditioning and chilled water plant equipped with controls
More informationHeating Controllers. Siemens Building Technologies HVAC Products. Synco 700
3 131 Synco 700 Heating Controllers Heating controller for medium-size and large buildings. The is used as a heating circuit or primary controller. The controller is supplied with 105 preprogrammed heating
More informationTracer Controls. Tracer MP.501 Controller BAS-PRC008-EN. June 2001
Tracer Controls Tracer MP.501 Controller June 2001 BAS-PRC008-EN Introduction The Tracer MP.501 controller is a configurable, multi-purpose controller used to provide direct-digital control for heating,
More informationFan coil (FCU) application guide
Fan coil (FCU) application guide SE7000 Series room controllers Control Performance Energy savings Better building management Table of contents Product & application selector... 4 Cost-saving, energy-saving
More informationEYE 200: DDC single-room controller, ecos200
Product data sheet 94.200 EYE 200: DDC single-room controller, ecos200 How energy efficiency is improved Individual unitary control, fan coil units, chilled-beam control system, etc. Features Part of the
More informationTF243 Series Digital Thermostat Fan Coil Unit Control
TF243 Series Digital Thermostat Fan Coil Unit Control Features SPECIFICATION DATA General The TF243 series digital thermostat is designed for 3-speed fan and modulating valve control in a fan coil system,
More informationCommunicating Thermostats. Add More Flexibility to Building Automation with. Communicating Thermostats
Communicating Thermostats Add More Flexibility to Building Automation with Communicating Thermostats More Choices. More Possibilities. From zone control to rooftop units and nearly everything in between,
More informationgesis FLEX Decentralized room automation Modular Compact Pluggable Room for the future.
gesis FLEX gesis FLEX Decentralized room automation Modular Compact Pluggable Room for the future. 2 gesis FLEX Room automation of the future Decentralized room automation with gesis FLEX In terms of flexibility,
More informationApplication program: description and examples
F a n C o i l U n i t C o n t r o l l e r F a n C o i l 4 9 5 5 1 Application program: description and examples Woertz AG Electrotechnical accessories, installation systems Hofackerstrasse 47, P.O. Box
More informationInstallation and Operation. Tracer MP501 Controller CNT-SVX08B-EN
Installation and Operation Tracer MP501 Controller CNT-SVX08B-EN Installation and Operation Tracer MP501 Controller CNT-SVX08B-EN April 2005 CNT-SVX08B-EN Tracer MP501 Controller Installation and Operation
More informationRCF-230CAD. Communicating room controller for fan-coil applications with two analogue V DC outputs
revision 01 2015 RCF-230CAD Communicating room controller for fan-coil applications with two analogue 0...10 V DC outputs RCF-230CAD intended to control heating and/or cooling in 2- or 4-pipe installations.
More informationHotel Solution HMI User's guide
s Hotel Solution HMI User's guide CM2B6307en 12/15/2008 For internal use only Building Technologies Siemens Switzerland Ltd Building Technologies Group International Headquarters Gubelstrasse 22 CH-6301
More information7-day room temperature controller
s 2 208 7-day room temperature controller Heating applications REV34.. Mains-independent, battery-operated room temperature controller featuring user-friendly operation, easy-to-read display and large
More informationTEC Unit Conditioner Controller
Document No. 540-1026 TEC Unit Conditioner Controller Generic Controller I/O Layout. See Wiring Diagram for application specific details. Control Applications 2040 and 2041 2050 through 2054 Product Description
More informationSED2 Variable Frequency Drives
Building Technologies SED2 Variable Frequency Drives More standard features Means better control of HVAC applications The global leader in Heating, Ventilation and Air Conditioning (HVAC) products and
More informationFANCOIL CONTROLLER UNIT TC17B01KNX. Product Handbook
FANCOIL CONTROLLER UNIT TC17B01KNX Product Handbook Product: TC17B01KNX Description: FANCOIL CONTROLLER UNIT Document Version: 1.2 Date: 09/09/2016 1/37 INDEX 1. General Introduction... 4 2. Product and
More informationExtension module for lighting control
s 3 842 DESIGO RXC Extension module for lighting control Extension to the RXC30 / RXC31 / RXC38 room controller RXC40.1 RXC40.5 The RXC40 extension module is used in conjunction with an RXC30, RXC31 or
More informationVC3000 Series Line Voltage Switching Relay Pack Controllers Installation Guide
Beyond Comfort VC3000 Series Line Voltage Switching Relay Pack Controllers Installation Guide August 10 th, 2010 (For Commercial and Lodging HVAC Fan Coil Applications) 028-0296-R1-LIT-VC3000-E01 Index
More informationCommercial Controls. Advanced control for saving time and money
L Connection NetWork Commercial Controls Advanced control for saving time and money The efficient way to control hvac and building operations L Connection Network at a glance: Controls a wide range of
More informationCONDUCTOR W4. Installation instruction for W4.1 and W To mount the controller. Controller. Mounting on a DIN rail
CONDUCTOR W Installation instruction for W. and W. 00 Controller To mount the controller. Mounting on a DIN rail Figure. Overview of the Controller. Pos. Product marking. Pos. Termination resistance. =
More informationTAC Xenta 101-VF. 3-Speed Fan Coil Controller. TAC Xenta
TAC Xenta TAC Xenta 101-VF 3-Speed Fan Coil Controller TAC Xenta 101-VF is a zone controller intended primarily for fan coil applications with the ability to control fans with multiple speeds, with one
More informationUSB-KNX Interface OCI702. USB-KNX interface with cables and service bag
USB-KNX Interface OCI702 USB-KNX interface with cables and service bag The USB-KNX interface OCI702 serves to provide a USB-KNX connection to access tools from a Microsoft Windows PC to a KNX network or
More informationTC-8900 Controller Units with PM-8900 Power Modules
European Electronic Controls Catalogue Catalogue Section F Product Bulletin PM-8900 Issue date 06 2000 TC-8900 Controller Units with PM-8900 Power Modules Introduction TC-8900 is a family of analogue controllers,
More informationEvolution TH. Pre-configured controller with display, clock and communication. Evolution. Applications. TH version. Sensors
Pre-configured controller with display, clock and communication Room controller for thermoregulation applications, equipped with rapid access buttons for the most common functions. Communication via RS485
More informationSE7600E Series Application Guide
Schneider Electric SE7600E Series RTU Controller with IAQ Control Application Guide CONTENTS Solution Overview 2 Product Overview 3 Features & Benefits 3 System Overview & Architecture 4 Models Available
More informationTLR-D42 with OPA-D42 Intelligent PI fan coil controller for modulating actuators. Cabinet mounted base, wall mounted operation terminal.
TLR-D42 with OPA-D42 Intelligent PI fan coil controller for modulating actuators. Cabinet mounted base, wall mounted operation terminal. Features Temperature control for 2-pipe and 4-pipe fan coil systems.
More informationWall-mounted sensors and room operator units for KNX/ETS and KNX/ACS Technical principles
s QMX3.P37 QMX3.P34 / P74 QMX3.P02 QMX3.P70 QMX3.P30 Wall-mounted sensors and room operator units for KNX/ETS and KNX/ACS Technical principles CM2N1602en_02 2015-04.28 Building Technologies Contents 1
More information