Automation station, compact series

Size: px
Start display at page:

Download "Automation station, compact series"

Transcription

1 s p0 DESIO INTERAL Migration Automation station, compact series PXC-NRUF In existing INTERAL plants, you can replace compact automation units NRUE/A, NRUF/A and NRUT/A with the PXC NRUF automation station. Same housing. Same periphery interface (plug compatible). Existing periphery can be assumed without a change. Use existing panel wiring. Compact, freely programmable automation station for HVAC and building services plants. Native BACnet automation station with communications BACnet via LonTalk BACnet PTP (point-to-point) Modem. PPC processor allows for high performance and reliable operation Comprehensive management and system functions (alarm management, schedulers, trends, remote management, access protection, etc.) physical inputs / outputs Stand-alone application or for use with linked system or devices. Supports the following operating elements: Room units QAX... Local / networkable operator units System or WEB operation via system network. CMN970en_0 Nov 009 Building Technologies

2 Functions Automation stations provide the infrastructure for recording and processing system and application-specification functions and are freely programmable. Comfortable management functions are integrated in addition to control functions, e.g.: Alarm management with alarm routing via the entire network. Standard, basis and expanded alarm management with checked secure transmission and automated transmission monitoring. Scheduler programs. Trend functions. Remote management function. Secured access to the entire network using individually defined user profiles and categories. Programming language The automation stations can be freely programmed (relying closely on CEN standard ) in D-MAP programming language. All function blocks, provided in libraries were graphically interconnected to plant operating programs. Communication The LONWORKS bus using internally standardized BACnet protocol is used for communications. Both peer-to-peer communication to other automation stations as well as connection to operating units PXM... are supported. Type summary Device Type Data point mix DI DO Automation station for physical data points PXC-NRUF Accessories Connecting cable between operating unit PXM0 or PXM0 and the automation station. Adapter for firmware download. Type designation PXA-C PXA-C / Siemens PXC-NRUF Automation station, compact series CMN970en_0 Building Technologies Nov 009

3 Equipment combinations Operation Various options exist to operating automation stations PXC-NRUF: Room device QAX... on the PPS interface. Up to a maximum of five room devices QAX... (without QAX...) can be connected. Details on PPS communication are described in the DESIO Technical principles manual (Section "I/O blocks", subsection "PPS addressing"). Local operator unit PXM0 *), is connected with cable PXA-C. Operator unit PXM0 *), is connecting with cable PXA-C, for local operation or for decentralized operation of an entire plant connected within a BACnet / LonTalk network. Note *) Only one operator unit can be connected (PXM0 or PXM 0). Web operation The web controller PX0-W allows for remote monitoring and operation of one or multiple DESIO PX automation stations using a standard Internet browser. The Web controller PX0-WN also includes an Ethernet connection. Technical design Inputs Universal inputs (... )can be used for active sensor elements as well as potential-free contracts for signaling functions. Digital inputs (DI ) allow non-potential-free reporting functions. They are electrically isolated from the system and from one another. Digital inputs (DI 9 ) allow reporting functions (potential-free). Digital inputs (DI 7 ) allow reporting and counting functions (potential-free). Outputs Universal outputs ( ) can, on the one hand, control modulating actuators, on the other hand, they can be programmed for binary switching functions via the program structure. Relay outputs (DO ) are designed for switching functions up to a maximum of AC/DC V, A. Siemens PXC-NRUF Automation station, compact series CMN970en_0 Building Technologies Nov 009 /

4 Power supply The device requires an external power supply AC/DCV /- 0%. It must comply with SELV / PELV requirements! The internal DC-DC converter supplies the internal processor system and inputs/outputs with controller voltage. DCV /00mA is also provided for active sensors (INTERAL periphery). This converter also establishes electrical isolation to the AC/DCV power supply. The device reset concept ensures defined conditions for field devices connected to the I/Os during power-up, power-down and undervoltage. Overvoltage protection and startup protection protect the automation station against fluctuating power. Design The compact construction allows you to install the automation station in narrow spaces and is particularly well suited for compact panels or for plants using integrated panels. Metal housing. Front cover, can be opened. LED displays. Plug-in terminal blocks. Terminal blocks Terminal block can be plugged in to ease field device connection. Existing INTERAL periphery can be plugged in at the same place as before. Note Older INTERAL systems, where the terminal blocks do not fit: Use the terminal blocks delivered with the PXC-NRUF. / Siemens PXC-NRUF Automation station, compact series CMN970en_0 Building Technologies Nov 009

5 LED displays RUN STATUS SERVICE TX LOW BATT INFO 97z0 LED Color Activity Function RUN reen Continuously off Continuously on No supply present. Supply present (LED controlled by SW). STATUS Red Continuously off Continuously on Flashes quickly Normal condition Hardware error recognized during self test or automation station in a state of "coma". There is no valid firmware present. SERVICE Red Continuously off Flashing Flashes in wink command rhythm * Continuously on LONWORKS node is configured. LONWORKS node is not configured. Physical identification of the automation upon receipt of the wink command. Neuron chip faulty or service button is pushed in. TX Yellow Flashing Data traffic on LONWORKS bus. LOW BATT Red Continuously off Continuously on Batteries OK (LED controlled by SW). Replace one or both batteries. INFO Red Freely programmable. * Wink command rhythm: s Hz Hz 000 s s s s Service button Identification of the automation station on the LONWORKS network: refer to "commissioning". Disposal The device is classified as waste electronic equipment in terms of the European Directive 00/9/EC (WEEE) and should not be disposed of as unsorted municipal waste. The relevant national legal rules are to be adhered to. Regarding disposal, use the systems setup for collecting electronic waste. Observe all local and applicable laws. Mounting notes The device can be attached directly to any surface with four screws, e.g. on the panel's base plate. Plug-in screw terminal blocks are provided to connect field devices, power and bus wiring. The other interfaces are connected using the quick plug-in connections. Do not open the device. All service functions are accessible via the lid. Siemens PXC-NRUF Automation station, compact series CMN970en_0 Building Technologies Nov 009 /

6 Commissioning The front cover may only be opened by instructed service staff! Comply with country-specific safety regulations and corresponding safety provisions to prevent personal injury or damage to property. Download plant operating programs The DESIO TOOLSET / XWORKS plus is used to download the plant operating program via the network (BACnet/LonTalk). Set parameters and configurations Use DESIO TOOLSET / XWORKS plus to set control parameters and configuration data. You can also edit data visible in the network using the PXM0 operator unit. Wiring tests Field devices and wiring can be tested with the operating unit PXM0 as soon as power is connected. There for loading the plant operating programs is not needed. Network connections The DESIO TOOLSET / XWORKS plus configures network addresses. For unique identification in the network (BACnet/LonTalk), press the service button or send a wink command to the corresponding automation station (service LED flashes). 970z0 Lithium battery AA Alkaline battery Force firmware download button Service button Reset button Firmware download The current D-MAP program is deleted from FLASH when the Firmware Download button is pressed during restart (reset). The automation station waits a moment for the signal to activate the FWLoaders and then starts the automation station. Restart Press the reset button to force a restart. / Siemens PXC-NRUF Automation station, compact series CMN970en_0 Building Technologies Nov 009

7 Maintenance notes Battery effective life Database information is stored in SDRAM memory, that is supported by a battery (alkaline type AA). This avoids costly reloads of programs and databases following a longer power outage (up to ca. month). The unused effective life for alkaline batteries is at least four years. The remaining life under load is just a few days following a "battery low" event. The real time clock is supported by a lithium battery with an effective life of at least 0 years. The LOW BATT LED is lit for insufficient load of one of the two batteries and the automation station automatically sends a system event and a device alarm. Replace battery Open the blue lid to replace the batteries. You can take out the batteries for as long as you want, when the unit is powered. STOP Caution! To prevent damage to the hardware from electrostatic discharge (ESD), use a grounded wristband to change batteries. Firmware upgrades Firmware and operating system are stored in non-volatile manner (on Flash ROM). It is easy to update the Flash ROM memory for the plant when new firmware versions become available. Siemens PXC-NRUF Automation station, compact series CMN970en_0 Building Technologies Nov /

8 Technical data eneral device data Operating voltage SELV / PELV AC/DC V ± 0 %. Rated voltage AC/DC V Frequency 0 / 0/0 Hz. Power consumption max. VA. Internal fuse thermal, automated reset. Functional data Processor Motorola PPC (MPC ). Storage location FLASH MB. RAM MB. Data backup during power outage Applications / Parameters (FLASH) > 0 years. Runtime data (buffered by AA alkaline, can be replaced on the plant) Unused: years. Typically month in case of supply failure (grid or AC V) Realtime clock 0 years. (buffered by Lithium battery, can be replaced on the plant). Precision category 0.. Sampling cycle max. second. Universal inputs Can be configured in software... A/D resolution (analog in) bit. Measured value inputs Area V. Input resistance 00 kω against. Sensor inputs Temperature sensor L-Ni 000, NI 000, Pt 000, T Measuring range C Sensor electricity (pulsed) approx.. ma (peak). Resolution 0. K. Meas. error at C (Ni 000, Pt 000) max. 0. K (excluding wire sensor). Measuring error at C (T) max..0 K (excluding wire sensor). Signal input Contact voltage DC 0... V. Contact electricity (pulsed) 7 ma (peak). Contact resistance Max. 00 Ω (closed). Insulation resistance Min. 0 kω (open). Digital inputs DI... Electrically isolated From system and from one another Not potential free. Area. Low < AC/DC V. High = AC/DC.. V ± 0%. Interior resistance. Ri = kω. Digital inputs DI 9... Contact voltage. DC 0... V. Contact current (continuous). 7 ma. Contact resistance. Max. 00 Ω (closed). Insulation resistance. Min. 0 kω (open). / Siemens PXC-NRUF Automation station, compact series CMN970en_0 Building Technologies Nov 009

9 Digital inputs DI 7... with counting function As DI 9... ; additionally counting function: Counter frequency (symmetrical) Min. closing/opening time incl. bouncing Max. bounce time Counter memory Max. Hz. 0 ms 0 ms Bit (0... max. cycle time 0 s at Hz) Counter inputs must be shielded, if they count faster than Hz and are routed with analog inputs in the same trunking for more than 0 m. Universal outputs Can be configured in software... D/A resolution (analog out) 0 bit. Modulating Output voltage range V. Output current Max.. ma source, max.. ma reduction. Digital Output voltage 0 / 0V Output current. ma Relay outputs Number of switching outputs (changeover contact) DO... External fuse protection for incoming cable Slow blow fusible link Max. 0 A Circuit breaker Max. A Circuit breaker tripping characteristic Type B, C or D to EN 09 Contact data AC/DC switching voltage max. AC V / DC V min. AC / DC V AC current rating Max. A resistive, A inductive Min. ma at AC V Min. 0 ma at AC V Current on make (AC) Max. 0 A ( s) DC current rating Max. A resistive at DC V Min. 0 ma resistive at DC V Response / dropout time 7 ms / ms typical Service life of contact for AC V (guide values) With 0. A resistive x 0 7 switching operations With 0. A resistive x 0 switching operations With.0 A resistive (N/O) x 0 switching operations Reduction factor with inductive load 0. (cos phi = 0.) Insulation resistance: Basic insulation AC 00 V, to EN 070- between relay outputs and system electronics Interface room units. Interface type PPS. Feed category Baud rate PPS. kbps. Interface LONWORKS bus. LONWORKS FTT transceiver (screw terminal). Network TP/FT-0. Baud rate 7 kbps. Protocol BACnet. Local communication (HMI, RJ). PXM0 (RS-). PXM0 (BACnet/LonTalk) One operator unit PXM0 or PXM 0 can be connected per automation station. LONWORKS bus instead of the RS bus used in INTERAL plants. Siemens PXC-NRUF Automation station, compact series CMN970en_0 Building Technologies Nov /

10 Plug-in screw terminals Power supply and signals Solid or stranded wire 0... mm or x. mm. LonWorks bus Solid or stranded wire x.0 mm. Simply cable lengths, Universal inputs Max. 00m with A = mm. and cable types Digital inputs DI Max. 00 m with diameter 0. mm. Universal outputs Max. 00m with A =. mm. Relay outputs DO Depends on load and local regulations. Interface room units PPS Max. m with A =.0 mm. Cable type -core, twisted pairs, unshielded. Capacity max. nf/km. Interface cable LONWORKS bus See installation guide PX, CA09. Cable type ConCab or CAT. Connecting cable PXM0 Max. m. Classification to EN 070 Automatic action Pollution degree Protection class Housing type. Protection as per EN 09 IP 0. Type III (Device also suitable for use in protection class II equipment) Ambient conditions Operation Class K as per IEC 07. Temperature C. Humidity..9 % r.h. (no condensation) Transportation Class K per IEC 07. Temperature C. Humidity 9 % r.h. (no condensation) Standards, guidelines and approvals Product standard Automatic electrical controls devices for EN household and similar use Special requirements for energy EN controllers Electromagnetic compatibility Immunity (industry) EN 070- Emissions (domestic) EN 070- CE conformity Electromagnetic compatibility C-Tick compliance per Australian EMC Framework Radio Emission Standard 00/0/EC Radio Communications Act 99 AS/NZS CISPR Dimensions Refer to dimensions Weight Excl. packaging packaged..90 kg.0 kg 0 / Siemens PXC-NRUF Automation station, compact series CMN970en_0 Building Technologies Nov 009

11 Connection diagrams Digital outputs Universal outputs Operator unit C. C. C. C. C. C. C.7 C. C. C. C. C. C. C. C.7 C. 7 9 DO DO DO DO 7 DO DO DO7 DO HMI A B C D E F H I J K L M N O P 7 I 7 J 7 K 7 L 7 M 7 N 7 O 7 P MODEM / COM DI7 C. DI C. DI9 C. DI0 C. 79 DI C. DI C. DI C.7 DI C. DO9 C.9 DO0 C.0 DO C. DO C. 9 DO C. DO C. DO C. DO C. 99 INTERAL Terminal DESIO Digital outputs Digital inputs (Potential free) Universal inputs Digital inputs (Potential free) C.9 DI9 C.0 DI0 C. DI C. DI 9 C. DI C. DI C. DI C. DI C.9 9 C.0 0 C. C. 7 C. C. C. C. I J K L M N O P DESIO Terminal INTERAL ( ) ND A B C D E F H I J K L M N O P CL A CL B V V ND 9 7 DI DI DI DI DI DI DI7 DI CP CP 9 7 PPS Supply LONWORKS C. C. C. C. C. C. C.7 C. C. C. C. C. C. C. C.7 C. 970A0 Digital inputs (not potential free) Universal inputs 7 DESIO Terminal INTERAL INTERAL Terminal DESIO STOP Caution! Observe the technical data for the relay outputs. Local installation regulations must be observed. / Siemens PXC-NRUF Automation station, compact series CMN970en_0 Building Technologies Nov 009

12 Pin occupancy "HMI" socket (LONWORKS) 7 9Z0 Pin description.. LONWORKS Data A (CLA).. LONWORKS Data B (CLB).. ND.. Plus V. Pin description.. Unoccupied.. Connected to. 7. COM / TxD.. COM / RxD. Interface Modem / COM Pin Abbr. Description DCD data carrier detect RXD received data TXD transmit data DTR data terminal ready ND signal ground DSR data set ready 7 RTS request to send CTS clear to send 9 NC not connected / Siemens PXC-NRUF Automation station, compact series CMN970en_0 Building Technologies Nov 009

13 Connect field devices STOP Note! This is a device using the -wire principle. System ground (0) and measuring ground ( or ND) are electrically isolated. For active field devices using -wire technology, this connection is in the field device. For active field devices using -wire technology, the connection must be established separately: Either at the terminal on the field device. Or in existing plants, using only wires: at the automation station between one of the terminals ( ) and 0. A) Field device supply of system transformer Compulsory specification for transformer Type Safety isolating transformer AC 0 V/AC V to EN Fusing AC V Max. 0A slow-blow (Extra-low voltage fuse) Max. A circuit breaker Counter inputs Counter inputs must be shielded, if they count faster than Hz and are laid with more than 0 meters using analog inputs in the same cable duct. Passive sensor (e.g. QAM..., Ni 000) AC V 0 Active sensor (e.g. QFM..., humidity) 00 0 V 970A0 ND CP CP- PXC NRUF M B M QFM... (r.h.) B M QAM... (Ni000) Magnetic valves (e.g. MP... ZM or MX...). AC V V ND CP CP- PXC NRUF N 970A0 MP... ZM MX... 0 (N) (L) YM Y / Siemens PXC-NRUF Automation station, compact series CMN970en_0 Building Technologies Nov 009

14 Motor valves AC V V ND CP CP- PXC NRUF 970A0 0 Y Damper actuators (e.g. BB.E). AC V V ND CP CP- PXC NRUF 970A0 BB.E B) Field device supply of separate transformers Magnetic valves (e.g. MP... ZM or MX...). AC V V ND CP CP- L N AC 0 V STOP Note! PXC NRUF AC V 0 970A07 0 (N) (L) YM Y Do NOT ground separate transformer MP... ZM MX... / Siemens PXC-NRUF Automation station, compact series CMN970en_0 Building Technologies Nov 009

15 C) Connect room units N Automation Station. AC V 0 R... Max. room units (parallel) PPS PPS Twisted pair bus cable. Interchangeable polarity Wire length, refer to "Technical data". V ND PXC NRUF CP CP- N C C CP CP C C CP CP R R C C CP CP 970A0 R Notes Room units are connected in parallel (maximal ). Must be addressed using a jumper to distinguish (address plug on the circuit board). The address factory set to. / Siemens PXC-NRUF Automation station, compact series CMN970en_0 Building Technologies Nov 009

16 Dimensions All dimensions in mm m0 / Siemens Switzerland Ltd. Subject to change Siemens PXC-NRUF Automation station, compact series CMN970en_0 Building Technologies Nov 009

Automation station, compact series

Automation station, compact series s 9 70 970p0 Desigo Integral Migration Automation station, compact series PXC-NRUF In existing Integral plants, you can replace compact automation units NRUE/A, NRUF/A and NRUT/A with the PXC NRUF automation

More information

Automation stations compact model

Automation stations compact model 9 PXC36-S DESIO PX Automation stations compact model PXC5 PXC36-S PXC5 Freely programmable compact automation stations for HVAC and building services systems The fixed data point mix ensures optimum efficiency

More information

PXR11 PXR12. System controllers DESIGO PX

PXR11 PXR12. System controllers DESIGO PX 9 235 DESIGO PX System controllers PXR11 PXR12 For integration of the room controllers in the DESIGO RXC range into the DESIGO building automation and control system (operates as an interface) For the

More information

Automation stations, compact model

Automation stations, compact model s 9 215 9215P01_01 Desigo PX Automation stations, compact model PXC...D PXC12.D PXC22.D PXC22.1.D PXC36.1.D PXC12-E.D PXC22-E.D PXC22.1-E.D PXC36.1-E.D Freely programmable compact automation stations for

More information

Automation stations, compact model

Automation stations, compact model s 9 215 9215P01_01 Desigo PX Automation stations, compact model PXC...D PXC12.D PXC22.D PXC22.1.D PXC36.1.D PXC12-E.D PXC22-E.D PXC22.1-E.D PXC36.1-E.D Freely programmable compact automation stations for

More information

Automation stations modular series

Automation stations modular series s 9 222 9222P01 DESIGO PX Automation stations modular series PXC...D PXC...-E.D PXA40- Freely programmable modular automation stations for HVAC and building services plants. Native BACnet automation station

More information

RXM39.1. PL-Link IO Block. Desigo TRA. Use with PXC3 series room automation station

RXM39.1. PL-Link IO Block. Desigo TRA. Use with PXC3 series room automation station s 3 836 3836P01 Desigo TRA PL-Link IO Block Use with PXC3 series room automation station RXM39.1 The PL-Link IO Block contains the inputs and outputs controlled by a room automation station via PL-Link.

More information

Extension module for Web functions generic

Extension module for Web functions generic s 9 264 9263p01 DESIGO PX Extension module for Web functions generic Plugs into the modular automation stations, type PXC...-U PXA30-W1 Extension module for PXC -U automation stations in the DESIGO building

More information

RXC39.5. Room controller. Building Technologies. Desigo RXC. Communicating room controller for fan-coil applications

RXC39.5. Room controller. Building Technologies. Desigo RXC. Communicating room controller for fan-coil applications s 3 856 Desigo RXC Room controller RXC39.5 Communicating room controller for fan-coil applications The RXC39.5 room controller is used for temperature control in individual rooms. For fan-coil systems

More information

RXL24.1. Room controller RXL. Communicating controller for chilled ceiling and radiator applications CC-02

RXL24.1. Room controller RXL. Communicating controller for chilled ceiling and radiator applications CC-02 s 3 878 RXL Room controller RXL24.1 Communicating controller for chilled ceiling and radiator applications CC-02 The RXL24.1 room controller is used for temperature control in individual rooms. For chilled

More information

Extension module for graphic Web functions for one automation station

Extension module for graphic Web functions for one automation station s 9 266 9263p01 DESIGO PX Extension module for graphic Web functions for one automation station Plugs into the modular automation stations, type PXC...-U For operation of the PXC -U automation stations

More information

Extension module for BACnet over Ethernet / IP and graphic Web functions

Extension module for BACnet over Ethernet / IP and graphic Web functions s 9 265 9263p01 DESIGO PX Extension module for BACnet over Ethernet / IP and graphic Web functions Plugs into the modular automation stations, type PXC...-U PXA30-W2 For operation of the PXC -U automation

More information

RXB39.1. Room controller RXB. Communicating room controller for fan-coil applications FC-13

RXB39.1. Room controller RXB. Communicating room controller for fan-coil applications FC-13 s 3 875 RXB Room controller Communicating room controller for fan-coil applications FC-13 RXB39.1 The RXB39.1 room controller is used for temperature control in individual rooms. For 2-pipe or 4-pipe fan-coil

More information

Web interface BACnet/IP

Web interface BACnet/IP s 9 294 DESIGO PX Web interface BACnet/IP PXG3.W100 Local or remote operation of one or multiple PX automation station(s) via Desigo Touch Panels (TP) and standard web browser Connection via Ethernet Central

More information

TXM1.8U TXM1.8U-ML. Universal modules TX-I/O

TXM1.8U TXM1.8U-ML. Universal modules TX-I/O 8 173 TX-I/O niversal modules TXM1.8 TXM1.8-ML Two fully compatible versions: TXM1.8: 8 inputs/outputs with LED signal / fault indication TXM1.8-ML: As TXM1.8, but with additional local override facility

More information

DESIGO RX Individual room controllers. for fan-coil systems, chilled ceilings and radiators, with LONMARK-compatible bus communications

DESIGO RX Individual room controllers. for fan-coil systems, chilled ceilings and radiators, with LONMARK-compatible bus communications 3 834 DESIO RX Individual room controllers for fan-coil systems, chilled ceilings and radiators, with MARK-compatible bus communications RXC20.1 RXC21.1 The RXC20.1 and RXC21.1 controllers are used for

More information

Power supply module, bus connection module

Power supply module, bus connection module s 8 183 8183p01, p02 TX-I/O Power supply module, bus connection module TXS1.12F10 TXS1.EF10 Each I/O row begins with one of these devices TXS1.12F10 power supply module Up to 4 power supply modules can

More information

Resistance measuring module

Resistance measuring module s 8 176 8176P01 TX-I/O Resistance measuring module TXM1.8P 8 inputs with LED signal / fault display. 8 resistance measuring inputs with individual configuration of resistance or temperature measurement.

More information

Automation stations modular series

Automation stations modular series s 9 222 9222P01 Desigo PX Automation stations modular series PXC...D PXC...-E.D PXA40- Freely programmable modular automation stations for HVAC and building services plants. Communications BACnet/IP BACnet/LonTalk

More information

RXL24.1. Room controller RXL. Communicating controller for chilled ceiling and radiator applications CC-02

RXL24.1. Room controller RXL. Communicating controller for chilled ceiling and radiator applications CC-02 s 3 878 RXL Room controller RXL24.1 Communicating controller for chilled ceiling and radiator applications CC-02 The RXL24.1 room controller is used for temperature control in individual rooms. For chilled

More information

Room unit with PPS2 interface

Room unit with PPS2 interface 1 642 Desigo RX Room unit with PPS2 interface for use with: QAX33.1 devices of the ranges Desigo RXC, RXB, RXL, and RXA (PPS2) Desigo PX Automation stations 1) devices with a PPS2 interface Room temperature

More information

RXB10.1. Room controller. Siemens Building Technologies Building Automation DESIGO RXB. for chilled ceilings and radiators with EIB bus communication

RXB10.1. Room controller. Siemens Building Technologies Building Automation DESIGO RXB. for chilled ceilings and radiators with EIB bus communication 3 870 DESIO RXB Room controller for chilled ceilings and radiators with EIB bus communication RXB10.1 The RXB10.1 controller is used for temperature control in individual rooms: For chilled ceilings and

More information

TXM1.8U TXM1.8U-ML. Universal modules TX-I/O

TXM1.8U TXM1.8U-ML. Universal modules TX-I/O s 8 173 TX-I/O niversal modules TXM1.8 TXM1.8-ML Two fully compatible versions: TXM1.8: 8 inputs/outputs with LED signal / fault indication TXM1.8-ML: As TXM1.8, but with additional local override facility

More information

CLIMATIX STEQ, STCM DATASHEET FOR CONTROLLING, SWITCHING AND MONITORING FUNCTIONS. POWER SUPPLY RELAY OUTPUTS. Power supply. 4.

CLIMATIX STEQ, STCM DATASHEET FOR CONTROLLING, SWITCHING AND MONITORING FUNCTIONS. POWER SUPPLY RELAY OUTPUTS. Power supply. 4. CLIMATIX STEQ, STCM DATASHEET FOR CONTROLLING, SWITCHING AND MONITORING FUNCTIONS. 4. Relays Power supply 2. Relays 8. Universal Inputs/ Process Bus (KNX) RS485 (Modbus) Tool (USB) Ethernet Tool (USB)/

More information

Island bus expansion module

Island bus expansion module s 8 184 8184P01 TX-I/O Island bus expansion TXA1.IBE Expand island bus to a distance of up to 2 x 200 meters Compact design per DIN 43 880, requires little space Easy installation and setup Mounted on

More information

TXM1.8T. Triac module Used for Thermic and motor-driven actuators (AC 24 V) TX-I/O

TXM1.8T. Triac module Used for Thermic and motor-driven actuators (AC 24 V) TX-I/O s 8 179 8179p01 TX-I/O Triac module sed for Thermic and motor-driven actuators (AC 24 V) AC 24 V-controlled devices TXM1.8T 8 triac outputs (AC 24 V), configured individually for: Permanent contact Three-point

More information

Room unit with PPS2 interface

Room unit with PPS2 interface s 1 640 1640P01 Desigo RX Room unit with PPS2 interface For use with: QAX34.3 Equipment from the RXC, RXB, RXL and RXA (PPS2) ranges Desigo PX automation stations 1) Devices with a PPS2 interface Measurement

More information

Room unit with PPS2 interface

Room unit with PPS2 interface 1 641 DESIGO RX Room unit with PPS2 interface for use with: QAX321 devices of the ranges DESIGO RXC, RXB, and RXA (PPS2) DESIGO PX Automation stations 1) devices with a PPS2 interface Room temperature

More information

BACnet/IP Web Interface

BACnet/IP Web Interface Desigo Control Point BACnet/IP Web Interface PXG3.W100-1, PXG3.W200-1 Web-based, graphical operation of BACnet automation stations using Desigo touch panels and devices with an HTML 5.0 web browser. Simultaneous

More information

Extension module Integration of existing PTM I/O modules in Desigo Used with PXC50...D, PXC100...D or PXC200...D

Extension module Integration of existing PTM I/O modules in Desigo Used with PXC50...D, PXC100...D or PXC200...D s 9 283 9283P01 Desigo PX Extension module Integration of existing PTM I/O modules in Desigo Used with PXC50...D, PXC100...D or PXX-PBUS The PXX-PBUS extension module allows for integrating existing PTM

More information

BACnet router for BACnet/IP BACnet/LonTalk BACnet MS/TP

BACnet router for BACnet/IP BACnet/LonTalk BACnet MS/TP s 9 270 Desigo PX BACnet router for BACnet/IP BACnet/LonTalk BACnet MS/TP PXG3.L PXG3.M Routing between BACnet/IP, BACnet/LonTalk (PXG3.L only), and BACnet MS/TP Supports BACnet/IPv4 and BACnet/IPv6 ANSI/ASHRAE

More information

Extension module for lighting control

Extension module for lighting control s 3 842 DESIGO RXC Extension module for lighting control Extension to the RXC30 / RXC31 / RXC38 room controller RXC40.1 RXC40.5 The RXC40 extension module is used in conjunction with an RXC30, RXC31 or

More information

Climatix TM Climatix Controller. For controlling, switching and monitoring functions

Climatix TM Climatix Controller. For controlling, switching and monitoring functions s A6V10759734 Climatix TM Climatix Controller POL422.50/ATL For controlling, switching and monitoring functions Main features Note The Climatix 422.50/ATL controller is HVAC controller optimized for air

More information

Non-communicating room controllers

Non-communicating room controllers 3 881 DESIO RXA on-communicating room controllers For fan-coil systems RXA20.1 RXA21.1 RXA22.1 The RXA20.1, RXA21.1 and RXA22.1 room controllers are used for temperature control in individual rooms. For

More information

Digital input modules

Digital input modules 8 172 TX-I/O Digital input modules TXM1.8D TXM1.16D Two fully compatible versions: TXM1.8D: 8 inputs, each with a three-color LED (green, yellow or red) TXM1.16D: As TXM1.8X, but 16 inputs, each with a

More information

MXPLC. Compact PLC process station. Summary. Application HVAC control systems, data acquisition, interfacing 3 rd party systems.

MXPLC. Compact PLC process station. Summary. Application HVAC control systems, data acquisition, interfacing 3 rd party systems. MXPLC Compact PLC process station Summary The MXPLC is a programmable process station with integrated I/O module with the I/O mix optimized for larger HVAC control applications. The multi-interface process

More information

Room automation station

Room automation station s 9 203 9203mmP01 Desigo TRA Room automation station PXC3.E7... Modular, programmable room automation stations for HVAC, lighting, and shading. BACnet / IP communications; BACnet profile ASC (BTL label).

More information

POL635.XX/XXX POL636.XX/XXX POL638.XX/XXX POL638.70/XXX

POL635.XX/XXX POL636.XX/XXX POL638.XX/XXX POL638.70/XXX s 3 230 Climatix TM Climatix Controllers For controlling, switching and monitoring functions POL635.XX/XXX POL636.XX/XXX POL638.XX/XXX POL638.70/XXX The controllers are products of the Climatix range.

More information

Non-communicating room controllers

Non-communicating room controllers 3 882 DESIGO RXA Non-communicating room controllers RXA29.1 For fan-coil systems The RXA29.1 room controller are used for temperature control in individual rooms. For 2-pipe or 4-pipe fan-coil systems,

More information

RXL21.1 RXL22.1. Room controllers RXL. Communicating controllers for fan-coil applications FC-10, FC-11, FC12

RXL21.1 RXL22.1. Room controllers RXL. Communicating controllers for fan-coil applications FC-10, FC-11, FC12 3 877 3877P0 RXL Room controllers Communicating controllers for fan-coil applications FC-0, FC-, FC2 RXL2. RXL22. The RXL2. and RXL22. room controllers are used for temperature control in individual rooms.

More information

TXM1.8RB. TX-I/O Blinds module

TXM1.8RB. TX-I/O Blinds module s 8 178 8178p01 TX-I/O Blinds module TXM1.8RB 8 non-floating relay outputs for... 4 blinds motors with 2 end switches, or 2 blinds motors with 3 end switches, or 2 blinds motors with 2 end switches + 1

More information

QAX50.1 QAX50.5 QAX51.1 QAX51.5. Flexible room unit. Desigo RXC

QAX50.1 QAX50.5 QAX51.1 QAX51.5. Flexible room unit. Desigo RXC 1 648 Desigo RXC Flexible room unit for integrated operation of HVAC, lighting and blinds in individual rooms; with LONMARK -compatible bus communication QAX50.1 QAX50.5 QAX51.1 QAX51.5 Room temperature

More information

RMZ792. Bus Operator Unit. Building Technologies HVAC Products. Synco 700

RMZ792. Bus Operator Unit. Building Technologies HVAC Products. Synco 700 3 113 Synco 700 Bus Operator Unit RMZ792 Communicating operator unit for operating up to 150 controllers, room units and central units from the Synco 700 range via Konnex bus. Favorite pages can be freely

More information

PXM20-E. Operator unit BACnet auf Ethernet/IP DESIGO PX

PXM20-E. Operator unit BACnet auf Ethernet/IP DESIGO PX 9 234 DESIGO PX Operator unit BACnet auf Ethernet/IP PXM20-E Network-compatible operator unit for viewing and operating one or more DESIGO PX automation stations. High-grade display with adjustable contrast

More information

Super universal modules

Super universal modules s 8 174 TX-I/O Super universal modules TXM1.8X TXM1.8X-ML Two fully compatible versions: TXM1.8X: 8 inputs/outputs with LED signal / fault indication TXM1.8X-ML: As TXM1.8X, but with additional local override

More information

Rotary version, three-position control

Rotary version, three-position control 4 622 Residential Air damper actuators GXD..31.1 Rotary version, three-position control Electric motor-driven actuators for three-position control 1.5 Nm nominal torque AC 24 V or AC 230 V rated voltage

More information

Room controller. For chilled ceiling and radiator applications CC-02 with Konnex bus communications (S-mode and LTE mode)

Room controller. For chilled ceiling and radiator applications CC-02 with Konnex bus communications (S-mode and LTE mode) s 3 874 RXB Room controller For chilled ceiling and radiator applications CC-02 with Konnex bus communications (S-mode and TE mode) RXB24.1 The RXB24.1 room controller is used for temperature control in

More information

EY-EM : Remote I/O module, ecolink

EY-EM : Remote I/O module, ecolink EY-EM 510...512: Remote I/O module, ecolink510...512 How energy efficiency is improved Optimum adjustment to applications by means of module technology. Reduction in wiring Features Part of the SAUTER

More information

RMZ782B RMZ783B. Extension Modules. Building Technologies HVAC Products. Synco 700. for heating controller RMH760B

RMZ782B RMZ783B. Extension Modules. Building Technologies HVAC Products. Synco 700. for heating controller RMH760B 3 136 Synco 700 Extension odules for heating controller RH760B RZ782B RZ783B Extension modules for use with the RH760B heating controller to provide additional auxiliary functions Use Heating plants controlled

More information

Automation stations modular series

Automation stations modular series s 9 222 9222P01 DESIGO PX Automation stations modular series PXC...D PXC...-E.D PXA40- Freely programmable modular automation stations for HVAC and building services plants. Native BACnet automation station

More information

QXA2000 QXA2001. Condensation Monitor QXA2001 QXA2000 AQX2000

QXA2000 QXA2001. Condensation Monitor QXA2001 QXA2000 AQX2000 1 542 1542P03 1542P01 1542P02 QXA2001 QXA2000 AQX2000 Condensation Monitor QXA2000 QXA2001 The QXA2000 condensation monitor is used to avoid damage due to condensation on chilled ceilings and in HVAC plant.

More information

M-bus web server. Meters and Energy Cost Allocation WTV676-HB6035

M-bus web server. Meters and Energy Cost Allocation WTV676-HB6035 Meters and Energy Cost Allocation M-bus web server WTV676-HB6035 The web server reads out wireless or wired M-bus devices over Ethernet or the Internet using a browser. Power and connection for up to 20

More information

9283P01. Extension module. Integration of existing PT-I/O modules in Desigo Used with PXC50...D, PXC100...D or PXC200...D

9283P01. Extension module. Integration of existing PT-I/O modules in Desigo Used with PXC50...D, PXC100...D or PXC200...D s 9 283 9283P01 Desigo PX Extension module Integration of existing PT-I/O modules in Desigo Used with PXC50...D, PXC100...D or PXX-PBUS The PXX-PBUS extension module allows for integrating existing PT-I/O

More information

Air damper actuators

Air damper actuators 4 604 OpenAir Air damper actuators Rotary version, AC/DC 24 V and AC 230 V GQD...1 GQD 1 Electric motor-driven actuators for two-position and three-position control as well as DC 0 10 V control 2 Nm nominal

More information

TXM1.8U TXM1.8U-ML. Universal modules TX-I/O

TXM1.8U TXM1.8U-ML. Universal modules TX-I/O s 8 173 TX-I/O niversal modules TXM1.8 TXM1.8-ML Two fully compatible versions: TXM1.8: 8 inputs/outputs with LED signal / fault indication TXM1.8-ML: As TXM1.8, but with additional local override facility

More information

Universal Controller

Universal Controller 3 342 Universal Controller For comfort control in HVAC & R-Systems Standalone electronic universal controller with P or PI response Operating voltage in accordance to type AC 24 V Control application selectable

More information

LON Module for Variable Speed Drive

LON Module for Variable Speed Drive 5 193. LON Module for Variable Speed Drive SED2 Conforms to and is certified to the LONMARK Interoperability Guidelines enabling information sharing with other LONMARK products. LONMARK-compliant with

More information

s Climatix AHU ext. module 14 I/O POL955.XX/XXX Climatix

s Climatix AHU ext. module 14 I/O POL955.XX/XXX Climatix s 3 262 Climatix Climatix AHU ext. module 14 I/O POL955.XX/XXX POL955.XX/XXX is a versatile Climatix extension module that can be connected to any type of Climatix POL6xx controller. Its high level of

More information

Duct Sensors. Building Technologies HVAC Products. Symaro. for relative humidity and temperature with calibration certificates

Duct Sensors. Building Technologies HVAC Products. Symaro. for relative humidity and temperature with calibration certificates 1 883 1883P01 1883P02 QFM4160 AQF4150 Symaro Duct Sensors for relative humidity and temperature with calibration certificates QFM41 Operating voltage AC 24 V / DC 1353 Signal output DC 010 V / 420 ma for

More information

NMID. Remote control. SAPIM I/O number. SAPIM I/O number NBRN (RS485) ZM100. Relay, 24 VDC - + UO07 UI11 UI10 UI09 UI08 UI07 UI06 UI05 UI04 UI03 UI02

NMID. Remote control. SAPIM I/O number. SAPIM I/O number NBRN (RS485) ZM100. Relay, 24 VDC - + UO07 UI11 UI10 UI09 UI08 UI07 UI06 UI05 UI04 UI03 UI02 1/8 NRK16/A, NRK16-B/A, (NRK16-T /A, NRK14-T /A, NRK16-WEB/A) Control and interlock devices with pre-programmed system-specific application modules The controllers may be used as stand-alone control and

More information

mark150s mark150/485s DDC controllers Summary

mark150s mark150/485s DDC controllers Summary mark150s mark150/485s DDC controllers Summary DDC (Direct digital control) controller mark150s and mark150/485s are free programmable process stations with ARM Cortex M4 processor and OS FreeRTOS. They

More information

SIMOCODE 3UF Motor Management and Control Devices

SIMOCODE 3UF Motor Management and Control Devices Technical specifications General data applicable to the basic units, current measuring modules, current/voltage measuring modules, expansion modules, decoupling module and operator panel Permissible ambient

More information

M-Bus Central Unit. Use

M-Bus Central Unit. Use 6 M-Bus Central Unit OZW The M-bus central unit is used for the remote readout, remote operation and supervision of an M-bus plant with a maximum of consumption meters and controllers featuring an M-bus

More information

Temperature Controller

Temperature Controller 2 728 Temperature Controller ultizone Floor Heating Systems RRV817 ultizone model with up to 7 zone outputs by combining 2 RRV817 controllers. Used for central control of underfloor heating systems in

More information

IMIO100 IMIO105. DDC controllers. Summary

IMIO100 IMIO105. DDC controllers. Summary IMIO100 IMIO105 DDC controllers Summary DDC (Direct digital control) controller IMIO100 and IMIO105 are free programmable process stations with ARM Cortex M4 processor and OS FreeRTOS. They contain one

More information

Product and functional description

Product and functional description Product and functional description The RS 525/23 Universal Dimmer is a KNX device with one dimmer output. The device is installed in an AP 118 Control Module Box or an AP 641 Room Control Box. The bus

More information

Temperature controller Ducted systems

Temperature controller Ducted systems 2 725 Temperature controller Ducted systems Standard model without zoning functions RRV851 Multifunctional controller used for central control of ducted HVAC systems in combination with a QAX850 master

More information

Room Temperature Controller

Room Temperature Controller 3 023 Room Temperature Controller for four-pipe fan coil units RCC30 Outputs for on / off valve actuators Outputs for three-speed fan Control depending on room or return air temperature Operating modes:

More information

RMZ782B RMZ783B. Extension Modules. Building Technologies HVAC Products. Synco 700. for heating controller RMH760B

RMZ782B RMZ783B. Extension Modules. Building Technologies HVAC Products. Synco 700. for heating controller RMH760B 3 136 Synco 700 Extension odules for heating controller RH760B RZ782B RZ783B Extension modules for use with the RH760B heating controller to provide additional auxiliary functions Use Heating plants controlled

More information

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency echnical data sheet LR24A-MOD Communicative rotary actuator for ball valves orque motor 5 Nm Nominal voltage AC/DC 24 V Control modulating,, hybrid mode Conversion of sensor signals Communication via BACnet

More information

VAV compact controller KNX / PL-Link

VAV compact controller KNX / PL-Link s 3 547 OpenAir VAV compact controller KNX / PL-Link Series E GDB181.1E/KN GLB181.1E/KN Networked compact controller featuring KNX (S-mode / LTE-mode) and PL- Link capability for plants with variable air

More information

Semi Flush-mount Room Temperature Controllers with LCD

Semi Flush-mount Room Temperature Controllers with LCD 3 076 RDF300, RDF300.02, RDF340 RDF400.01 Semi Flush-mount Room Temperature Controllers with LCD for 2-pipe, 2-pipe with el. heater and 4-pipe fan coil units for use with compressors in DX type equipment

More information

Status display unit with P-bus connection

Status display unit with P-bus connection 8 917 DESIO TM I/O modules with P-bus connection PHM1.36TL for connections to automation stations with P-bus for status indication of up to 24 messages for remote control of up to 12 operating points in

More information

LM24A-MOD. Cable 1 m, 6 x 0.75 mm 2 RJ12 socket

LM24A-MOD. Cable 1 m, 6 x 0.75 mm 2 RJ12 socket echnical data sheet Damper actuator for Modbus for adjusting air dampers in ventilation and air conditioning systems in buildings orque 5 Nm Nominal voltage AC/DC 4V Communication via Modbus RU (RS-485)

More information

General information. Display. Supply voltage. Input current

General information. Display. Supply voltage. Input current Datasheet SIMATIC S7-1200, CPU 1212C, COMPACT CPU, DC/DC/DC, ONBOARD I/O: 8 DI 24V DC; 6 DO 24 V DC; 2 AI 0-10V DC, POWER SUPPLY: DC 20.4-28.8 V DC, PROGRAM/DATA MEMORY: 50 KB General information Engineering

More information

OHIO SEMITRONICS, INC. AC MULTIFUNCTION PROGRAMMABLE TRANSDUCERS & -1000L

OHIO SEMITRONICS, INC. AC MULTIFUNCTION PROGRAMMABLE TRANSDUCERS & -1000L AC PROGRAMMABLE TRANSDUCERS MODBUS OR LONWORKS DESCRIPTION The DMT-1000 is a programmable transducer with an RS-485 bus interface (MODBUS ). It supervises several variables of a poly-phase electrical power

More information

Communication module to connect M-bus devices to POL6xx.xxx controllers.

Communication module to connect M-bus devices to POL6xx.xxx controllers. s 3 936 Climatix TM Climatix communication M-Bus module POL907.00/xxx Communication module to connect M-bus devices to POL6xx.xxx controllers. The POL907.00/xxx communication module offers the following

More information

7-day room temperature controller

7-day room temperature controller s 2 208 7-day room temperature controller Heating applications REV34.. Mains-independent, battery-operated room temperature controller featuring user-friendly operation, easy-to-read display and large

More information

Weekday / weekend room temperature controller

Weekday / weekend room temperature controller s 2 203 Weekday / weekend room temperature controller Heating applications REV17.. Mains-independent, battery-operated room temperature controller featuring user-friendly operation, easy-to-read display

More information

SAX.. ACVATIX Electromotive actuators for valves. with a 20 mm stroke

SAX.. ACVATIX Electromotive actuators for valves. with a 20 mm stroke s 4 501 ACVATIX Electromotive actuators for valves SAX.. with a 20 mm stroke SAX31.. Operating voltage AC 230 V, 3-position control signal SAX61.. Operating voltage AC/DC 24 V, control signal DC 0 10 V,

More information

General information Engineering with Programming package. Display with display. Supply voltage 24 V DC Yes

General information Engineering with Programming package. Display with display. Supply voltage 24 V DC Yes Datasheet SIMATIC S7-1200, CPU 1215C, COMPACT CPU, DC/DC/DC, 2 PROFINET PORT, ONBOARD I/O: 14 DI 24V DC; 10 DO 24V DC 0.5A 2 AI 0-10V DC, 2 AO 0-20MA DC, POWER SUPPLY: DC 20.4-28.8 V DC, PROGRAM/DATA MEMORY:

More information

MXIO. Compact I/O module. Summary. Application Compact I/O module for data acquisition and HVAC control systems. Function

MXIO. Compact I/O module. Summary. Application Compact I/O module for data acquisition and HVAC control systems. Function MXIO Compact I/O module Summary The MXIO multiple I/O compact module is a microprocessor-controlled, communicative module with the I/O mix optimized for larger HVAC control applications. The module uses

More information

Compact Series Unitary Equipment Controller

Compact Series Unitary Equipment Controller Technical Specification Sheet Document No. 149-837 February 20, 2018 Compact Series Unitary Equipment Controller Figure 1. PXC Compact Series Unitary Equipment Controllers (PXC UEC-16/24). The PXC Compact

More information

Display. Supply voltage. Input current. Encoder supply. Output current. Power losses. Memory

Display. Supply voltage. Input current. Encoder supply. Output current. Power losses. Memory Datasheet SIMATIC S7-1200, CPU 1214C, COMPACT CPU, AC/DC/RLY, ONBOARD I/O: 14 DI 24V DC; 10 DO RELAY 2A; 2 AI 0-10V DC, POWER SUPPLY: AC 85-264 V AC AT 47-63 HZ, PROGRAM/DATA MEMORY: 75 KB Display with

More information

7-day room temperature controller

7-day room temperature controller s 2 205 7-day room temperature controller Heating or cooling applications REV24.. Mains-independent, battery-operated room temperature controller featuring user-friendly operation, easy-to-read display

More information

Room sensors QFA4160 QFA41 D AQF4150 AQF3153. Symaro. for relative humidity and temperature with calibration certificates

Room sensors QFA4160 QFA41 D AQF4150 AQF3153. Symaro. for relative humidity and temperature with calibration certificates 1 859 1859P01 1859P02 1859P04 QFA4160 QFA41 D AQF4150 AQF3153 Symaro Room sensors for relative humidity and temperature with calibration certificates QFA41 Operating voltage AC 24 V / DC 13.5...3 Signal

More information

General information. Display. Supply voltage. Input current. Encoder supply. Output current

General information. Display. Supply voltage. Input current. Encoder supply. Output current Data sheet SIMATIC S7-1200, CPU 1211C, COMPACT CPU, AC/DC/RELAY, ONBOARD I/O: 6 DI 24V DC; 4 DO RELAY 2A; 2 AI 0-10V DC, POWER SUPPLY: AC 85-264 V AC AT 47-63 HZ, PROGRAM/DATA MEMORY: 50 KB General information

More information

TAC Xenta 301. Controller, Freely Programmable

TAC Xenta 301. Controller, Freely Programmable TAC Xenta TAC Xenta 300 Controller, Freely Programmable TAC Xenta 300 belongs to a family of freely programmable controllers designed for small and medium-sized heating and air handling systems. A TAC

More information

Display. Supply voltage. Input current. Encoder supply. Output current. Power losses. Memory

Display. Supply voltage. Input current. Encoder supply. Output current. Power losses. Memory Datasheet SIMATIC S7-1200, CPU 1214C, COMPACT CPU, DC/DC/DC, ONBOARD I/O: 14 DI 24V DC; 10 DO 24 V DC; 2 AI 0-10V DC, POWER SUPPLY: DC 20.4-28.8 V DC, PROGRAM/DATA MEMORY: 75 KB Display with display Supply

More information

General information. Display. Supply voltage. Input current. Encoder supply. Output current

General information. Display. Supply voltage. Input current. Encoder supply. Output current Data sheet SIMATIC S7-1200, CPU 1214C, COMPACT CPU, DC/DC/RELAY, ONBOARD I/O: 14 DI 24V DC; 10 DO RELAY 2A; 2 AI 0-10V DC, POWER SUPPLY: DC 20.4-28.8 V DC, PROGRAM/DATA MEMORY: 75 KB General information

More information

Universal Modules. Synco 700. Extension modules for use with controls of the Synco 700 family. Use

Universal Modules. Synco 700. Extension modules for use with controls of the Synco 700 family. Use s 3 146 Synco 700 Universal Modules RMZ78 Extension modules for use with controls of the Synco 700 family. Use For heating, ventilation, air conditioning and chilled water plant equipped with controls

More information

Semi flush-mounted room temperature controllers with LCD

Semi flush-mounted room temperature controllers with LCD s 3 077 RDD310 RDE410 Semi flush-mounted room temperature controllers with LCD For heating systems RDD310 RDE410 RDD310 and RDE410 features: Operating voltage AC 230 V 2-position control with On / Off

More information

Room unit with PPS2 interface

Room unit with PPS2 interface 1 626 Room unit with PPS2 interface for use with: controllers with a PPS2 interface QAA88.3 Room temperature measurement Key buttons for adjustment of the room temperature setpoint Key buttons for operating

More information

General information. Display. Supply voltage. Input current. Encoder supply. Output current

General information. Display. Supply voltage. Input current. Encoder supply. Output current Data sheet SIMATIC S7-1200, CPU 1214C, COMPACT CPU, DC/DC/DC, ONBOARD I/O: 14 DI 24V DC; 10 DO 24 V DC; 2 AI 0-10V DC, POWER SUPPLY: DC 20.4-28.8 V DC, PROGRAM/DATA MEMORY: 75 KB General information Engineering

More information

Product and functional description

Product and functional description Product and functional description The RS 520/23 shutter / blind actuator is a KNX device with one relay output. The device is installed in an AP 118 Control Module Box or an AP 641 Room Control Box. The

More information

General information. Display. Supply voltage. Input current. Encoder supply. Output current

General information. Display. Supply voltage. Input current. Encoder supply. Output current Data sheet SIMATIC S7-1200, CPU 1215C, COMPACT CPU, DC/DC/DC, 2 PROFINET PORT, ONBOARD I/O: 14 DI 24V DC; 10 DO 24V DC 0.5A 2 AI 0-10V DC, 2 AO 0-20MA DC, POWER SUPPLY: DC 20.4-28.8 V DC, PROGRAM/DATA

More information

EXOcompact. Third generation freely programmable controllers

EXOcompact. Third generation freely programmable controllers revision 1 013 EXOcompact Third generation freely programmable controllers Small, compact controller with different types of communication, with or without built-in display. EXOcompact can be used either

More information

General information. Display. Supply voltage. Input current. Encoder supply. Power losses

General information. Display. Supply voltage. Input current. Encoder supply. Power losses Data sheet SIMATIC S7-1200, CPU 1215C, COMPACT CPU, DC/DC/RELAY, 2 PROFINET PORT, ONBOARD I/O: 14 DI 24V DC; 10 DO RELAY 2A, 2 AI 0-10V DC, 2 AO 0-20MA DC, POWER SUPPLY: DC 20.4-28.8 V DC, PROGRAM/DATA

More information

Manual Industry Interfaces

Manual Industry Interfaces Manual Industry Interfaces W&T Release. Type 0, 0 0, 00 0, 0 0, 0 Industry Interfaces 0/0 by Wiesemann & Theis GmbH Subject to errors and changes: Since we can make mistakes, none of our statements should

More information

General information. Display. Supply voltage. Input current. Encoder supply. Output current

General information. Display. Supply voltage. Input current. Encoder supply. Output current Data sheet SIMATIC S7-1200, CPU 1211C, COMPACT CPU, DC/DC/RELAY, ONBOARD I/O: 6 DI 24V DC; 4 DO RELAY 2A; 2 AI 0-10V DC, POWER SUPPLY: DC 20.4-28.8 V DC, PROGRAM/DATA MEMORY: 50 KB General information

More information