HP StorageWorks. EVA Virtualization Adapter administrator guide
|
|
- Aubrey Hopkins
- 6 years ago
- Views:
Transcription
1 HP StorageWorks EVA Virtualization Adapter administrator guide Part number: Third edition: September 2009
2 Legal and notice information Copyright Hewlett-Packard Development Company, L.P. Confidential computer software. Valid license from HP required for possession, use or copying. Consistent with FAR and , Commercial Computer Software, Computer Software Documentation, and Technical Data for Commercial Items are licensed to the U.S. Government under vendor's standard commercial license. The information contained herein is subject to change without notice. The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. HP shall not be liable for technical or editorial errors or omissions contained herein.
3 Contents 1 Overview of HP EVA Virtualization Adapter... 7 Discovery of disk arrays and LUNs... 7 Disk array discovery sequence... 8 LUN discovery sequence... 8 Failover testing... 9 Failover recovery... 9 Communication path Replication options Command View EVA Configuration Options Configuring SRM and the HP EVA disk array Setting up the HP EVA SAN environment Adding an ESX server Installing licenses Creating vdisks for datastores Presenting LUNs Creating and configuring datastores Installing HP EVA Virtualization Adapter Pairing SRM sites Configuring SRM to communicate with HP Command View EVA Create protection groups Create recovery plans Installing and removing HP EVA Virtualization Adapter Installation directory Installation prerequisites Installing HP EVA Virtualization Adapter Checking the installation Removing HP EVA Virtualization Adapter Failover and failback with SRM Failover Failback Failback scenario with SRM Snapconfig utility Troubleshooting HP EVA Virtualization Adapter HP StorageWorks EVA disk arrays do not appear in Site Recovery Manager HP StorageWorks EVA Virtualization Adapter does not install Virtual machines do not start at recovery site after failover Site Recovery Manager timeout failure in large array configurations Virtual machines do not start at recovery site during the test failover test Error messages EVA Virtualization Adapter administrator guide 3
4 SRM log EVA log HP EVA Virtualizaton Error Messages Reference Intended audience Related documentation Document conventions and symbols HP technical support Subscription service HP websites Documentation feedback Glossary Index
5 Figures Discovered Information... 8 Using snapshots for failover test... 9 HP EVA Virtualization Adapter architecture Snapconfig.xml file EVA Virtualization Adapter administrator guide 5
6 Tables 1 EVA Virtualization Adapter log messages
7 1 Overview of HP EVA Virtualization Adapter HP StorageWorks EVA Virtualization Adapter (HP EVA Virtualization Adapter) is installed on VMware Site Recovery Manager (SRM) servers and enables communications between SRM and HP StorageWorks Command View EVA (and HP StorageWorks Continuous Access EVA for remote replication). HP EVA Virtualization Adapter performs the following functions: Discovers disk arrays Discovers replicated LUNs Fails over storage for testing (test a recovery plan) Fails over storage for recovery (execute a recovery plan) For detailed operational information on HP StorageWorks Command View EVA, HP StorageWorks Continuous Access EVA, HP StorageWorks Business Copy EVA, or VMware Site Recovery Manager see the sources cited in Related documentation. Discovery of disk arrays and LUNs During SRM configuration, HP EVA Virtualization Adapter is called to discover available arrays and replicated LUNs. The following information is discovered: Storage array IDs (WWN) Controller Port WWNs Physical host HBAs LUNs assigned to local (protected) physical and virtual hosts Remote recovery storage array ID Remote vdisk name Remote vdisks are members of HP EVA data replication groups, and are replicated between protected and recovery HP EVAs using HP Continuous Access EVA. EVA Virtualization Adapter administrator guide 7
8 . Figure 1 Discovered Information Disk array discovery sequence The array discovery sequence is: 1. SRM makes a request to HP EVA Virtualization Adapter for available arrays. 2. HP EVA Virtualization Adapter connects to HP Command View EVA servers and requests array controller port information (WWN). 3. HP EVA Virtualization Adapter returns the results to SRM. LUN discovery sequence The LUN discovery sequence is: 1. SRM makes a request to HP EVA Virtualization Adapter for replicated LUNs on a local (protected) array. 2. HP EVA Virtualization Adapter connects to HP Command View EVA servers and requests replicated vdisks on the protected array. 3. HP Command View EVA looks for vdisks that are members of data replication groups. 4. For each replicated vdisk found on the protected array, HP EVA Virtualization Adapter gathers the following information: Remote array ID Remote vdisk name Local presentation information Host the LUN is presented to ID assigned to host 5. HP EVA Virtualization Adapter returns this information to SRM. 6. SRM correlates LUNs with datastores. 8 Overview of HP EVA Virtualization Adapter
9 . Failover testing HP EVA Virtualization Adapter provides information and performs EVA operations for nondisruptive testing of SRM failover recovery plans. SRM uses the information gathered during the discovery process to create snapshots of remote vdisks (see Figure 2). After testing verifies the vdisks snapshots can be recovered after failure of the local array (via a recovery plan), SRM uses HP StorageWorks EVA Virtualization Adapter to unpresent and delete the snapshots. HP Business Copy EVA is used to create snapshots during recovery plan testing. NOTE: For Failover, the ESX LVM settings must be set to default for Snapshot (default is disallow) and resignature (default is allow). Figure 2 Using snapshots for failover test Failover recovery During recovery, SRM executes a recovery plan. When SRM reaches the Prepare Storage step in the recovery plan, it provides the LUN information needed for failover to HP EVA Virtualization Adapter. The information includes: Recovery site storage array ID Vdisk name Recovery ESX server HBA ports (WWNs) for post-failover LUN presentation EVA Virtualization Adapter administrator guide 9
10 . HP EVA Virtualization Adapter then communicates with HP Command View EVA and correlates the requested vdisks with data replication groups. The adapter fails over each data replication group associated with the LUN information provided by SRM. HP EVA Virtualization Adapter then obtains LUN presentation information for each vdisk that has failed over and returns the information to SRM. The information includes: vdisk name LUN number assignment to recovery HBA ports NOTE: During initial setup, replicated vdisks need to be presented to both the protected and recovery ESX hosts. NOTE: For failover testing, LUN number assignment is the LUN number used by the snapshot and not the parent vdisk. Communication path HP EVA Virtualization Adapter provides communications between HP StorageWorks Command View EVA and SRM. A detailed view of the architecture is shown in Figure 3. HP EVA Virtualization Adapter processes SRM requests through HP Command View EVA. Once the information is received by HP EVA Virtualization Adapter, it is passed on to SRM. Figure 3 HP EVA Virtualization Adapter architecture 10 Overview of HP EVA Virtualization Adapter
11 Replication options SRM with HP EVA Virtualization Adapter supports HP Continuous Access EVA synchronous and asynchronous replication operations. Command View EVA Configuration Options There are two configuration options for the disaster recovery environment with SRM and HP EVA Virtualization Adapter: Single active Command View EVA server In this configuration, the Command View EVA management server manages the protected and recovery arrays actively. A second Command View EVA management server manages the protected and recovery arrays passively. NOTE: In this configuration (during failover or test failover) if the primary Command View EVA site is down, the recovery Command View EVA site will be forced to actively manage the recovery array. Split active Command View EVA server In this configuration, each Command View EVA management server actively manages a single array (the local array). Each Command View EVA management server manages the remote array passively. EVA Virtualization Adapter administrator guide 11
12 12 Overview of HP EVA Virtualization Adapter
13 2 Configuring SRM and the HP EVA disk array This chapter summarizes the steps to set up SRM and the HP EVA disk array for use with HP EVA Virtualization Adapter. For detailed information on these steps, see the documents listed in Related documentation. The following steps need to be completed: 1. Set up EVA SAN environment. 2. Install HP EVA Virtualization Adapter. 3. Pair SRM sites (Protected/Recovery). 4. Configure SRM to communicate with Command View EVA. 5. Create Protection Group(s). 6. Create Recovery Plan(s). Setting up the HP EVA SAN environment Setting up the EVA SAN environment involves the following steps: Set up zones Install licenses for HP StorageWorks Continuous Access EVA and HP StorageWorks Business Copy EVA Create vdisks for datastores Add vdisks to data replication groups Create datastores Adding an ESX server After zoning, use HP Command View EVA to add an ESX server to the hosts that are available to the local HP EVA disk array. You can assign an alias (host name) to HBA ports (initiator IDs) that can be seen by the HP EVA disk array and will be used for LUN presentation. For more information on these tasks, see the HP StorageWorks Command View EVA user guide. Installing licenses HP StorageWorks Continuous Access EVA (needed to create replication pairs and perform failover between data centers) and HP StorageWorks Business Copy EVA (needed to create snapshots during recovery plan testing) need to be on the HP EVA disk arrays at the protected site and recovery site. For more information on HP StorageWorks Continuous Access EVA and HP StorageWorks Business Copy EVA, see the documents in Related documentation. EVA Virtualization Adapter administrator guide 13
14 NOTE: Snapclones, mirrorclones, and the ability to choose different disk group for clones are not currently supported with SRM or HP EVA Virtualization Adapter. Creating vdisks for datastores Vdisks (vdisks) need to be created for virtual machine datastores. Create the vdisks on the protected HP EVA disk array, using HP StorageWorks Command View EVA or HP StorageWorks Storage System Scripting Utility (SSSU) Command Line Interface. Once vdisks have been created on the local EVA, create data replication groups containing the vdisks. Data replication groups are created on the local HP EVA disk array and provide vdisk failover between two HP EVA disk arrays. You can create data replication groups using HP StorageWorks Command View EVA or SSSU. For more information on these tasks, see the HP StorageWorks Command View EVA user guide and the HP StorageWorks Storage Software Scripting Utility Reference. Presenting LUNs Once vdisks have been created and put into a data replication group local LUNs should be presented to local ESX server. When you put a vdisk into a data replication group, it will be replicated to the remote EVA. At the remote data center, you then need to present the replica vdisk to the ESX servers that are hosts to the remote EVA. After you present the vdisks to both local and remote ESX servers, log into the local ESX servers and do a rescan. There is no need to rescan for LUNs on the remote ESX servers, since SRM does this during failover. You can present LUNs using HP StorageWorks Command View EVA or SSSU. For more information on these tasks, see the HP StorageWorks Command View EVA user guide and the HP StorageWorks Storage Software Scripting Utility Reference. Creating and configuring datastores The following tasks need to be done on protected and recovery ESX servers after LUN presentation: On protected ESX servers Create datastores on ESX server Install virtual machines onto the datastores Create resource pools and folders as needed On recovery ESX servers Rescan to make sure LUNs can be seen from protected site For more information on these tasks, see the VMware Site Recovery Manager Administration Guide. Installing HP EVA Virtualization Adapter To install HP EVA Virtualization Adapter, see Chapter 3 14 Configuring SRM and the HP EVA disk array
15 Pairing SRM sites You should now pair the protected and recovery sites in SRM. For more information, see the VMware Site Recovery Manager Administration Guide. Configuring SRM to communicate with HP Command View EVA When the protected and recovery SRM servers have been paired, configure SRM to use HP EVA Virtualization Adapter by configuring array managers. To configure SRM to communicate with HP Command View EVA disk arrays, complete the following steps: 1. Click Configure on the summary tab. EVA Virtualization Adapter administrator guide 15
16 2. From the Configure Array Managers window, click Add to add connection information for the Command View EVA servers managing your EVA disk arrays. 3. In the Add Array Manager window, enter the storage manager addresses, usernames, and passwords in the entry fields without spaces and separating each entry with a semicolon (;). For example: Storage Manager Address - address1;address2 Username - username1;username2 Password - password1;password2 NOTE: With this release, HP EVA Virtualization Adapter limits the number of Command View EVA management servers that can be configured to two (one in each data center). From the Manager Type menu, select HP StorageWorks Enterprise Virtual Array. Then enter the address and login credentials used for HP Command View EVA and click Connect. After the connection completes, all HP EVA disk arrays managed by the HP Command View EVA server are displayed. 16 Configuring SRM and the HP EVA disk array
17 4. Select the HP EVA disk array name that is connected to protected ESX servers. NOTE: You will also need to configure the recovery site array manager using this procedure. EVA Virtualization Adapter administrator guide 17
18 5. Verify that the array managers are configured by looking for the following information in the Configure Array Managers window: Array Manager Info Local and remote array information LUN count (equals the number of replicated LUNs on each EVA) 6. Verify the array mangers have been configured for both protected and recovery sites, and replicated datastores in the Review Replicated Datastores window. Create protection groups You are ready to create protection groups in the protected site using SRM. Protection groups (containing virtual machines) fail over together to the recovery site during test and recovery. For more information on creating protection groups, see the VMware Site Recovery Manager Administration Guide. 18 Configuring SRM and the HP EVA disk array
19 Create recovery plans Create recovery plans on the recovery site. A recovery plan is a list of steps the SRM follows on a protected site to switch operation from the protected site to the recovery site during a disaster (or test). For more information on creating recovery plans, see the VMware Site Recovery Manager Administration Guide. EVA Virtualization Adapter administrator guide 19
20 20 Configuring SRM and the HP EVA disk array
21 3 Installing and removing HP EVA Virtualization Adapter This chapter explains how to install and configure HP EVA Virtualization Adapter. NOTE: You do not need to remove the previous HP EVA Virtualization Adapter when upgrading to a newer version. IMPORTANT: A successful installation depends on using compatible versions of the OS and all installed software. See HP EVA Virtualization Adapter release notes for version requirements. Installation directory Depending on the version of SRM, HP EVA Virtualization Adapter is installed in the following (default) directoy: For SRM 1.0 C:\Program Files\VMware\VMware Site Recovery Manager\scripts\SAN\HP StorageWorks EVA Virtualization Adapter For SRM 4.0 C:\Program Files\VMware\VMware vcenter Site Recovery Manager\scripts\ SAN\SAN\HP StorageWorks EVA Virtualization Adapter Installation prerequisites To install HP EVA Virtualization Adapter, you need administrator privileges, and VMware Site Recovery Manager must already be installed on the server. Installing HP EVA Virtualization Adapter HP EVA Virtualization Adapter is installed using an executable (setup.exe). EVA Virtualization Adapter administrator guide 21
22 NOTE: HP EVA Virtualization Adapter must be installed on both the local site SRM server (protected site) and the remote site SRM server (recovery site). 1. Download HP EVA Virtualization Adapter installation file from the HP web page ( and save it in a temporary folder. 2. Browse to the temporary folder and extract HP EVA Virtualization Adapter installation files. 3. After the files are extracted, click Setup.exe to start the installation. The InstallShield Wizard window appears. 4. Click Next. The License Agreement window opens. 5. Click I accept the terms of the license agreement and then click Next. The Ready to Install the Program window opens. 6. Click Install. 7. At the prompt indicating the Site Recovery Manager Service needs to be restarted, click OK. The InstallShield Wizard Complete window opens. 22 Installing and removing HP EVA Virtualization Adapter
23 8. Click Finish to complete the installation. You will need to restart Site Recover Manager (see Restarting Site Recovery Manager. NOTE: After this step, a readme file is displayed. Restarting Site Recovery Manager 1. Restart Site Recovery Manager by clicking Start > Settings > Control Panel. 2. Double-click Administrative Tools. then double-click Services. NOTE: Restarting the SRM service halts any operations SRM may have been performing and requires you to configure the connection between SRM sites. (see Configuring SRM to communicate with HP Command View EVA and Pairing SRM sites). 3. Select the VMware Site Recovery Manager Service in the list and click Restart. Checking the installation After HP EVA Virtualization Adapter is installed, it appears in the Windows Add or Remove Programs window. EVA Virtualization Adapter administrator guide 23
24 Removing HP EVA Virtualization Adapter To remove HP EVA Virtualization Adapter: 1. In Windows, select Start > Settings > Control Panel. 2. Double-click Add or Remove Programs. 3. Select HP StorageWorks EVA Virtualization Adapter. 4. Click Change/Remove. Windows removes the program. NOTE: After removing HP EVA Virtualization Adapter, restart SRM service so it can be reflect that EVA Virtualization Adapter is no longer available. 24 Installing and removing HP EVA Virtualization Adapter
25 4 Failover and failback with SRM This section discusses failover and failback with SRM. It also provides a scenario as a guide for the manual process of failback. Failover Failover occurs when an SRM recovery plan is executed, and the SRM recovery plan is configured to fail over SRM protection groups that use replicated EVA vdisks as a datastore. During normal operation, the replication path is from a protected site (local site) to a recovery site (remote site). When a failure occurs at the local site (due to hardware failure or the entire site loss) a failover occurs and the replication path is reversed from the recovery site to the protected site. With HP EVA Virtualization Adapter and SRM, the failover process is an automated feature and the process is executed using a recovery plan located at the recovery site. NOTE: HP recommends that the user sets the DR group write mode to Sync before performing a planned failover. This will ensure: the data is current the failover does not result in full-copy (reverse copy) from secondary site to primary site vdisks Failback Failback is the process of setting the replication environment back to its original state at the protected site (local site) prior to failover. Failback can be managed as a normal server migration process. However, managing the failback process with SRM is a manual process and the steps vary with respect to the degree of failure at the protected site (local site). For example, the failover could have been due to a hardware error or the loss of the entire data center. Failback scenario with SRM In the following failback scenario, SRM is used as a failback tool to return a protected site (Site A) to its original state after executing a recovery plan (R1) at a recovery site (Site B). To execute a failback manually: 1. Delete recovery plan at the recovery site (Site B). 2. If the protected site (Site A) still has HP Continuous Access EVA or data replication groups configured for the protection groups (P1) in recovery plan (R1), delete protection groups (P1) at the protected site. This could be the case if some of the hardware at the protected site was not replaced after a disaster and you will be employing the existing hardware. If new hardware has been installed, it is not necessary to delete existing protection groups. EVA Virtualization Adapter administrator guide 25
26 3. If you have not already, install SRM and HP EVA Virtualization Adapter on the updated hardware at the protected site (Site A). 4. Using the VI Client at the recovery site (Site B), establish the protected site (Site A) as the remote site for the recovery site (Site B). 5. Configure array replication from the recovery site (Site B) to the protected site (Site A) for datastores containing recovered virtual machines. For more information, see the HP StorageWorks Continuous Access EVA administrator guide. 6. Create any protection group(s) (P2) at the recovery site (Site B) to protect the recovered virtual machines at the protected site (Site A). 7. On the protected machine (Site A) create a recovery plan (R2) for the protection group(s) (P2) 8. After the virtual machines have been fully replicated to the protected site (Site A), execute recovery plan R2 at the protected site (Site A) in test mode. 9. If the test is successful, execute the recovery plan (R2) in recovery mode. If desired, you can now protect the recovered virtual machines on the protected site (Site A) back to the recovery site (Site B). To do this, perform the following steps: 1. Delete the recovery plan R2 from the protected site (Site A). 2. Delete the protection group(s) P2 at the recovery site (Site B). 3. Configure array replication from the recovery site (Site B) to the protected site (Site A) for datastores containing recovered virtual machines. For more information, see the HP StorageWorks Continuous Access EVA administrator guide. 4. Create protection group(s) P3 at the protected site (Site A) to protect recovered virtual machines from the protected site (Site A) to the recovery site (Site B). 5. Create a recovery plan R3 at the recovery site (Site B) for the protection group(s). Snapconfig utility The Snapconfig utility file is an xml file that is installed with HP EVA Virtualization Adapter, and is used during failover test operations. Typically, this file is not modified; however, it can be used to customize the way test snapshots are created. After installation, Snapconfig.xml can be edited in the Windows Notepad and accessed from Start->All Programs->Hewlett-Packard->StorageWorks EVA Virtualization->SRM SnapConfig Utility The parameters that can be modified using Snapconfig are RAID type and allocation policy. The possible settings for RAID type are: vraid5 (default) vraid0 The possible settings for allocation type are: demand (default) full A listing of the default file is show in Figure 4. NOTE: Any changes made to SnapConfig.xml will be global to all vdisks created during a test failover. 26 Failover and failback with SRM
27 . Figure 4 Snapconfig.xml file NOTE: With the current release, <SnapType> and <Continue> are deprecated. EVA Virtualization Adapter administrator guide 27
28 28 Failover and failback with SRM
29 5 Troubleshooting HP EVA Virtualization Adapter NOTE: Error messages are logged to the SRM log files. The following problems and solutions are typical. HP StorageWorks EVA disk arrays do not appear in Site Recovery Manager Solutions: If HP EVA disk arrays are not appearing in Site Recovery Manager, make sure that Site Recovery Manager has been restarted (see Restarting Site Recovery Manager, page 23). Also make sure that the array manager that SRM is connected to is actively managing arrays. HP StorageWorks EVA Virtualization Adapter does not install Solution: Make sure that SRM is installed. HP EVA Virtualization Adapter will not install if SRM is not on the disk array. Virtual machines do not start at recovery site after failover. Causes: The ESX recovery hosts are not configured with the correct HBA port WWN on the recovery EVA. The replicated vdisks used in failover were not presented to the recovery ESX servers. Site Recovery Manager timeout failure in large array configurations Solution: Increase the SRM timeout value (CommandTimeout) by editing the vmware-dr.xml file located in the <SRM Install Path>\config directory as shown in the following example: </SanProvider>. EVA Virtualization Adapter administrator guide 29
30 .. <!.. Timeout in seconds for execution of a single command using array vendor adapter. Default: 5 minutes > <CommandTimeout> 300 </CommandTimeout> </SanProvider> NOTE: After increasing the SRM timeout value, you will need to restart the VMware Site Recovery Manager service. Virtual machines do not start at recovery site during the test failover test. Causes: The ESX recovery hosts are not configured with the correct HBA port WWN on the recovery EVA. Error messages HP EVA Virtualization Adapter error messages are logged to SRM and HP EVA Virtualization Adapter log files. Table 1 lists error messages and their meanings. SRM log SRM Logs (vmware-dr-x.log (X=0 to 9) is located in: %ALLUSERSPROFILE%\Application Data\VMware\VMware Site Recovery Manager\Logs ALLUSERSPROFILE=C:\Documents and Settings\All Users NOTE: Logs rollover after reaching 5 MB by default vmware-dr-index contains the most recent Log File number EVA log HP EVA Virtualization Adapter log (hpsrmeva.log) is located in: <SRM Install Path>\scripts\SAN\HP StorageWorks EVA Virtualization Adapter\ logs For the <SRM Install Path>, see Installation directory, page Troubleshooting HP EVA Virtualization Adapter
31 HP EVA Virtualizaton Error Messages Table 1 EVA Virtualization Adapter log messages Log Message Array <EVA ID>s being actively managed by a different SMA Could not create snapshot Could not determine DR Group membership of one or more virtual disk Could not find the specified VDisk: <LUN ID> Could not populated array information Could not populated list of managed arrays Creating snapshot of <LUN ID> Data Replication Group for <DR Group> already in source mode Failover of DR Group <DR Group name> was unsuccessful Initialization of CV Client failed using IP address <management host address> Initialization of the Element Manager object failed No test snapshots found Presentation of the vdisk <LUN ID> to the host <host name> has failed previously created SRM snapshot found Storage Array <EVA ID> not found on current management host Successfully deleted <SRM test snapshot name> There are no Data Replication Groups to failover VDisk <LUN ID> is not a member of a known Data Replication Group Description The array being requested by SRM is actively managed by a different Command View EVA host. During a test failover operation, the action to create a snapshot failed due to an internal error on the EVA. A LUN ID was input from SRM to the adapter, but it could not be found in any existing DR Group. A LUN ID was input from SRM to the adapter, but it could not be found on the EVA. A connection was made to Command View EVA, but the EVA information could not be obtained. A connection was made to Command View EVA, but the EVA information could not be obtained. A snapshot of the replicated LUN is currently being created. A LUN ID input from SRM has already been failed over at the DR Group level. During a failover of a DR Group associated with a replicated LUN, an error occurred. The address or login credentials to the management host may be incorrect, preventing the adapter from connecting. Connection to the Command View EVA host could not be initialized. A test failover stop operation was called, but no test snapshots from the test failover stop operation exists. During a test failover operation, the presentation of a snapshot to a ESX host failed due to an internal error on the EVA. During test failover start or stop, a test SRM snapshot has been detected on the array. The array being requested by SRM is actively managed by a different Command View EVA host. During test failover stop, a test SRM snapshot has been deleted. All replicated LUNs specified by SRM are already in a failed over state, or do not belong to a DR Group. A LUN ID input from SRM does not belong to any known DR Group. EVA Virtualization Adapter administrator guide 31
32 32 Troubleshooting HP EVA Virtualization Adapter
33 6 Reference This guide provides information about: HP StorageWorks EVA Virtualization Adapter (HP EVA Virtualization Adapter) for HP StorageWorks EVA disk arrays Requirements and procedures for installing HP EVA Virtualization Adapter Configuring HP EVA Virtualization Adapter For supported disk array models and operating system versions, see the release notes for HP EVA Virtualization Adapter. For information on VMware and VMware Site Recovery Manager, see the VMware website. This guide does not describe the operation of related products, including HP StorageWorks Command View EVA, HP StorageWorks Continuous Access EVA, HP StorageWorks Business Copy EVA, HP StorageWorks Storage Software Scripting Utility, or VMware Site Recovery Manager. For information about these products, see the respective user guides. Intended audience This guide is intended for system administrators with knowledge of: Host hardware HP StorageWorks EVA disk arrays VMware Site Recovery Manager (SRM) Related documentation The following documents provide related information: HP StorageWorks Continuous Access EVA administrator guide HP StorageWorks Business Copy EVA administrator guide HP StorageWorks Command View EVA user guide HP StorageWorks Storage System Scripting Utility reference You can find these documents from the Manuals page of the HP Business Support Center website: Below Storage, click Storage Software. The following book is available on the VMware website: VMware Site Recovery Manager Administration Guide EVA Virtualization Adapter administrator guide 33
34 Document conventions and symbols Convention Blue text: Document conventions and symbols Blue, underlined text: Bold text Italic text Element Cross-reference links and addresses Website addresses Keys that are pressed Text typed into a GUI element, such as a box GUI elements that are clicked or selected, such as menu and list items, buttons, tabs, and check boxes Text emphasis CAUTION: Indicates that failure to follow directions could result in damage to equipment or data. IMPORTANT: Provides clarifying information or specific instructions. NOTE: Provides additional information. TIP: Provides helpful hints and shortcuts. HP technical support For worldwide technical support information, see the HP support website: Before contacting HP, collect the following information: Product model names and numbers Technical support registration number (if applicable) Product serial numbers Error messages Operating system type and revision level Detailed questions 34 Reference
35 Subscription service HP recommends that you register your product at the Subscriber's Choice for Business website: After registering, you will receive notification of product enhancements, new driver versions, firmware updates, and other product resources. HP websites For additional information, see the following HP websites: Documentation feedback HP welcomes your feedback. To make comments and suggestions about product documentation, please send a message to storagedocsfeedback@hp.com. All submissions become the property of HP. EVA Virtualization Adapter administrator guide 35
36 36 Reference
37 Glossary This glossary defines acronyms and terms used in this guide or related to this product and is not a comprehensive glossary of computer terms. Command View EVA disk array DR Group EVA failback failover HBA LUN Protected Site RAID Recovery Site snapshot SRM HP StorageWorks Command View, a browser-based interface that allows management of an HP disk array. A RAID. A collection of disk drives within a cabinet or multiple cabinets and including a controller and software allowing drives to be ganged together in various configurations to create virtual drives (LUNs). Data replication group. A logical group of vdisks in a remote replication relationship with a corresponding group on another array. HP StorageWorks Enterprise Virtual Array. Restoring a system back to its original state after a system failure. When the recovery site takes over operation in place of the protected site after hardware or the entire protected site fails. Host Bus Adapter Logical Unit Number. A physically addressable storage unit as surfaced by a hardware RAID subsystem. A vdisk, consisting of multiple portions of physical disks addressed as a single unit. The datacenter containing the protected virtual machines from which data is being replicated to the recovery site. Redundant array of independent disks. The datacenter containing the virtual machines that will be recovered and perform work while the protected site is unavailable. A generic term meaning a static point-in-time copy of a volume, typically used for backup. VMware Site Recovery Manager EVA Virtualization Adapter administrator guide 37
38 38 Glossary
39 Index A audience, 33 C communications path overview, 10 conventions document, 34 D document conventions, 34 documentation providing feedback, 35 related, 33 documentation, HP website, 33 E error messages, 29, 30 F Failback overview, 25 scenario, 25 Failover overview, 25 Failover testing overview, 9 HP StorageWorks EVA Virtualization Adapter checking installation, 23 installation, 21 installation directory, 21 installation prerequisites, 21 installation process, 21 overview, 7 R related documentation, 33 S Site Recovery Manager (SRM) discovery process, 7 Snapconfig utility overview, 26 Subscriber's Choice, HP, 35 T technical support HP, 34 service locator website, 35 troubleshooting, 29 W websites, 33 HP, HP Subscriber's Choice for Business, 35 G glossary, 37 H help obtaining, 34 HP technical support, 34 EVA Virtualization Adapter administrator guide 39
40 40
Guidelines for using Internet Information Server with HP StorageWorks Storage Mirroring
HP StorageWorks Guidelines for using Internet Information Server with HP StorageWorks Storage Mirroring Application Note doc-number Part number: T2558-96338 First edition: June 2009 Legal and notice information
More informationHP P6000 Cluster Extension Software Installation Guide
HP P6000 Cluster Extension Software Installation Guide This guide contains detailed instructions for installing and removing HP P6000 Cluster Extension Software in Windows and Linux environments. The intended
More informationMac OS X Fibre Channel connectivity to the HP StorageWorks Enterprise Virtual Array storage system configuration guide
Mac OS X Fibre Channel connectivity to the HP StorageWorks Enterprise Virtual Array storage system configuration guide Part number: 5697-0025 Third edition: July 2009 Legal and notice information Copyright
More informationHP LeftHand P4000 Virtual SAN Appliance in an HP BladeSystem environment solution guide
HP LeftHand P4000 Virtual SAN Appliance in an HP BladeSystem environment solution guide AT459-96002 Part number: AT459-96002 First edition: April 2009 Legal and notice information Copyright 2009 Hewlett-Packard
More informationHP EVA Cluster Extension Software Installation Guide
HP EVA Cluster Extension Software Installation Guide Abstract This guide contains detailed instructions for installing and removing HP EVA Cluster Extension Software in Windows and Linux environments.
More informationP9000 Virtualization Adapter Administrator Guide
HP StorageWorks P9000 Virtualization Adapter Administrator Guide This guide contains detailed instructions for installing and removing the P9000 Virtualization Adapter. The intended audience has independent
More informationHP Intelligent Management Center v7.1 MySQL 5.6 Installation and Configuration Guide (Windows)
HP Intelligent Management Center v7.1 MySQL 5.6 Installation and Configuration Guide (Windows) Abstract This document provides installation and configuration information for MySQL. It includes the procedures
More informationHP 3PAR Storage Replication Adapter 5.0 for VMware vcenter Site Recovery Manager
HP 3PAR Storage Replication Adapter 5.0 for VMware vcenter Site Recovery Manager Troubleshooting Guide Abstract This document provides troubleshooting and workflow information for the HP 3PAR Storage Replication
More informationHP OpenView Storage Data Protector A.05.10
HP OpenView Storage Data Protector A.05.10 ZDB for HP StorageWorks Enterprise Virtual Array (EVA) in the CA Configuration White Paper Edition: August 2004 Manufacturing Part Number: n/a August 2004 Copyright
More informationHP StorageWorks 4000/6000/8000 Enterprise Virtual Array connectivity for Sun Solaris installation and reference guide
HP StorageWorks 4000/6000/8000 Enterprise Virtual Array connectivity for Sun Solaris installation and reference guide Part number: 5697-5263 First edition: May 2005 Legal and notice information Copyright
More informationHP StoreVirtual Storage Multi-Site Configuration Guide
HP StoreVirtual Storage Multi-Site Configuration Guide Abstract This guide contains detailed instructions for designing and implementing the Multi-Site SAN features of the LeftHand OS. The Multi-Site SAN
More informationHP Virtual Connect Enterprise Manager
HP Virtual Connect Enterprise Manager Data Migration Guide HP Part Number: 487488-001 Published: April 2008, first edition Copyright 2008 Hewlett-Packard Development Company, L.P. Legal Notices Confidential
More informationDell PowerVault MD Storage Array VMware Storage Replication Adapter (SRA) Installation and Configuration Manual
Dell PowerVault MD Storage Array VMware Storage Replication Adapter (SRA) Installation and Configuration Manual Regulatory Model: E16S Series Regulatory Type: E16S001 Notes, Cautions, and Warnings NOTE:
More informationHP StoreVirtual Storage Multi-Site Configuration Guide
HP StoreVirtual Storage Multi-Site Configuration Guide Abstract This guide contains detailed instructions for designing and implementing the Multi-Site SAN features of the LeftHand OS. The Multi-Site SAN
More informationHP StorageWorks Enterprise Virtual Array 4400 to 6400/8400 upgrade assessment
HP StorageWorks Enterprise Virtual Array 4400 to 6400/8400 upgrade assessment Part number: 5697-8185 First edition: June 2009 Legal and notice information Copyright 2009 Hewlett-Packard Development Company,
More informationHewlett Packard Enterprise. HPE OmniStack for vsphere Upgrade Guide
Hewlett Packard Enterprise HPE OmniStack for vsphere Upgrade Guide Part number: P00126-001 Published: September 2017 2017 Hewlett Packard Enterprise Development LP Notices The information contained herein
More informationHP Intelligent Management Center Remote Site Management User Guide
HP Intelligent Management Center Remote Site Management User Guide Abstract This book provides overview and procedural information for Remote Site Management, an add-on service module to the Intelligent
More informationHP StorageWorks Continuous Access EVA 2.1 release notes update
HP StorageWorks Continuous Access EVA 2.1 release notes update Part number: T3687-96038 Third edition: August 2005 Legal and notice information Copyright 2005 Hewlett-Packard Development Company, L.P.
More informationVMware vcenter Site Recovery Manager 4.1 Evaluator s Guide EVALUATOR'S GUIDE
VMware vcenter Site Recovery Manager 4.1 EVALUATOR'S GUIDE Table of Contents. Getting Started.... 3 About VMware vcenter Site Recovery Manager.... 3 About This Guide.... 3 Intended Audience.... 3 Assumptions....
More informationHP Enterprise Secure Key Manager Configuration Guide for HP Tape Libraries
HP Enterprise Secure Key Manager Configuration Guide for HP Tape Libraries Abstract This document provides information about configuring the HP Enterprise Secure Key Manager (ESKM) for use with HP tape
More informationHP P4000 Remote Copy User Guide
HP P4000 Remote Copy User Guide Abstract This guide provides information about configuring and using asynchronous replication of storage volumes and snapshots across geographic distances. For the latest
More informationHP ALM Client MSI Generator
HP ALM Client MSI Generator Software Version: 1.00 User Guide Document Release Date: October 2010 Software Release Date: October 2010 Legal Notices Warranty The only warranties for HP products and services
More informationHP EVA Cluster Extension Software Administrator Guide
HP EVA Cluster Extension Software Administrator Guide Abstract This guide contains detailed instructions for configuring and troubleshooting HP EVA Cluster Extension Software. The intended audience has
More informationProLiant Cluster HA/F500 for Enterprise Virtual Array Introduction Software and Hardware Pre-Checks Gathering Information...
Installation Checklist HP ProLiant Cluster F500 for Enterprise Virtual Array 4000/6000/8000 using Microsoft Windows Server 2003, Enterprise Edition Stretch Cluster May 2005 Table of Contents ProLiant Cluster
More informationHP LeftHand SAN Solutions
HP LeftHand SAN Solutions Support Document Installation Manuals VSA 8.0 Quick Start - Demo Version Legal Notices Warranty The only warranties for HP products and services are set forth in the express warranty
More informationHP Modular Smart Array FC VDS Hardware Provider administration guide
HP Modular Smart Array FC VDS Hardware Provider administration guide Part number: T1634-96072 Second edition: May 2006 Legal and notice information Copyright 2005-2006 Hewlett-Packard Development Company,
More informationHP OneView for VMware vcenter User Guide
HP OneView for VMware vcenter User Guide Abstract This document contains detailed instructions for configuring and using HP OneView for VMware vcenter (formerly HP Insight Control for VMware vcenter Server).
More informationv7.0 Intelligent Management Center MySQL 5.5 Installation and Configuration Guide (for Windows)
v7.0 Intelligent Management Center MySQL 5.5 Installation and Configuration Guide (for Windows) Abstract This document is intended to be the installation and configuration guide for MySQL in addition to
More informationHP 3PARInfo 1.4 User Guide
HP 3PARInfo 1.4 User Guide Abstract This guide provides information about installing and using HP 3PARInfo. It is intended for system and storage administrators who monitor and direct system configurations
More informationHP Insight Remote Support Advanced HP StorageWorks P4000 Storage System
HP Insight Remote Support Advanced HP StorageWorks P4000 Storage System Migration Guide HP Part Number: 5900-1089 Published: August 2010, Edition 1 Copyright 2010 Hewlett-Packard Development Company, L.P.
More informationHP StorageWorks Replication Solutions Manager installation guide
HP StorageWorks Replication Solutions Manager installation guide Part number: T3680-96016 Third edition: July 2006 Legal and notice information Copyright 2005-2006 Hewlett-Packard Development Company,
More informationHPE ALM Client MSI Generator
HPE ALM Client MSI Generator Software Version: 12.55 User Guide Document Release Date: August 2017 Software Release Date: August 2017 HPE ALM Client MSI Generator Legal Notices Warranty The only warranties
More informationIDE Connector Customizer Readme
IDE Connector Customizer Readme Software version: 1.0 Publication date: November 2010 This file provides information about IDE Connector Customizer 1.0. Prerequisites for IDE Connector Customizer The Installation
More informationHP OneView for VMware vcenter User Guide
HP OneView for VMware vcenter User Guide Abstract This document contains detailed instructions for configuring and using HP OneView for VMware vcenter (formerly HP Insight Control for VMware vcenter Server).
More informationDell PowerVault MD Series VMware Storage Replication Adapter (SRA) Installation and Configuration Manual (Web Client)
Dell PowerVault MD Series VMware Storage Replication Adapter (SRA) Installation and Configuration Manual (Web Client) Notes, cautions, and warnings NOTE: A NOTE indicates important information that helps
More informationVirtual Recovery Assistant user s guide
Virtual Recovery Assistant user s guide Part number: T2558-96323 Second edition: March 2009 Copyright 2009 Hewlett-Packard Development Company, L.P. Hewlett-Packard Company makes no warranty of any kind
More informationHP ProLiant Agentless Management Pack (v 3.2) for Microsoft System Center User Guide
HP ProLiant Agentless Management Pack (v 3.2) for Microsoft System Center User Guide Abstract This guide provides information on using the HP ProLiant Agentless Management Pack for System Center version
More informationHP StorageWorks Modular Smart Array FC VDS Hardware Provider for Windows 2003 administration guide
HP StorageWorks Modular Smart Array FC VDS Hardware Provider for Windows 2003 administration guide Part number: T1634-96074 Third edition: February 2007 Legal and notice information Copyright 2005, 2007
More informationHP Data Protector Media Operations 6.11
HP Data Protector Media Operations 6.11 Getting started This guide describes installing, starting and configuring Media Operations. Copyright 2009 Hewlett-Packard Development Company, L.P. Part number:
More informationHP StorageWorks Partitioning in an EBS Environment Implementation Guide
HP StorageWorks Partitioning in an EBS Environment Implementation Guide Part number: 381448-002 First edition: November 2004 Copyright 2004 Hewlett-Packard Development Company, L.P. Hewlett-Packard Company
More informationHP StorageWorks Enterprise Virtual Array
Release Notes HP StorageWorks Enterprise Virtual Array Product Version: v3.025 First Edition March, 2005 Part Number: 5697 5237 *5697-5237* This document contains the most recent product information about
More informationOMi Management Pack for Microsoft SQL Server. Software Version: For the Operations Manager i for Linux and Windows operating systems.
OMi Management Pack for Microsoft Software Version: 1.01 For the Operations Manager i for Linux and Windows operating systems User Guide Document Release Date: April 2017 Software Release Date: December
More informationHPE 3PAR Storage Replication Adaptor for Stretched storage support with VMware vcenter Site Recovery Manager. Technical White Paper
HPE 3PAR Storage Replication Adaptor for Stretched storage support with VMware vcenter Site Recovery Manager Technical White Paper Contents Introduction... 3 Scope of the document... 3 Document purpose...
More informationHP ProLiant Hardware Inventory Tool for Configuration Manager 2007 User Guide
HP ProLiant Hardware Inventory Tool for Configuration Manager 2007 User Guide HP Part Number: Part Number 530778-003 Published: May 2010 (Fourth Edition) Notices Copyright 2009, 2010 Hewlett-Packard Development
More informationHP StorageWorks XP Hardware Providers administration guide
Windows 2003 HP StorageWorks XP Hardware Providers administration guide XP128 XP1024 XP12000 product version: 2.8 first edition (February 2005) part number: T1634-96030 This guide explains how to install
More informationHP Service Test Management
HP Service Test Management for the Windows operating system Software Version: 11.00 Installation Guide Document Release Date: February 2011 Software Release Date: February 2011 Legal Notices Warranty The
More informationDell Storage Compellent Integration Tools for VMware
Dell Storage Compellent Integration Tools for VMware Administrator s Guide Version 3.1 Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make better use of your
More informationDell Storage Compellent Integration Tools for VMware
Dell Storage Compellent Integration Tools for VMware Version 4.0 Administrator s Guide Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make better use of your
More informationSite Recovery Manager Administration. Site Recovery Manager 6.0
Site Recovery Manager Administration Site Recovery Manager 6.0 You can find the most up-to-date technical documentation on the VMware website at: https://docs.vmware.com/ If you have comments about this
More informationHP 3PAR StoreServ Storage VMware ESX Host Persona Migration Guide
HP 3PAR StoreServ Storage VMware ESX Host Persona Migration Guide Abstract This guide is intended to assist customers in successfully migrating their VMware ESX/ESXi hosts on HP 3PAR StoreServ storage
More informationDell Storage Integration Tools for VMware
Dell Storage Integration Tools for VMware Version 4.1 Administrator s Guide Notes, cautions, and warnings NOTE: A NOTE indicates important information that helps you make better use of your product. CAUTION:
More informationHP Enterprise Integration module for SAP applications
HP Enterprise Integration module for SAP applications Software Version: 2.60 User Guide Document Release Date: December 2010 Software Release Date: December 2010 Legal Notices Warranty The only warranties
More informationInstallation and Configuration Guide (for Linux)
v5.2 MySQL 5.5 Installation and Configuration Guide (for Linux) Abstract This document is intended to be the installation and configuration guide for MySQL in addition to the procedures for upgrading,
More informationHP P4000 SAN Solution User Guide
HP P4000 SAN Solution User Guide Abstract This guide provides information for configuring and using the HP SAN Solution. It includes hardware configuration and information about designing and implementing
More informationHP Storage Provisioning Manager (SPM) Version 1.3 User Guide
HP Storage Provisioning Manager (SPM) Version 1.3 User Guide Abstract This guide provides information to successfully install, configure, and manage the HP Storage Provisioning Manager (SPM). It is intended
More informationHPE StoreEver MSL6480 Tape Library Version 5.50 Firmware Release Notes
HPE StoreEver MSL6480 Tape Library Version 5.50 Firmware Release Notes Abstract This document provides information about enhancements and fixes to the firmware for the HPE StoreEver MSL6480 Tape Library.
More informationHP ALM Synchronizer for Agile Manager
HP ALM Synchronizer for Agile Manager Software Version: 2.10 User Guide Document Release Date: August 2014 Software Release Date: August 2014 Legal Notices Warranty The only warranties for HP products
More informationHP BladeSystem c-class Virtual Connect Support Utility Version Release Notes
HP BladeSystem c-class Virtual Connect Support Utility Version 1.9.1 Release Notes Abstract This document provides release information for the HP BladeSystem c-class Virtual Connect Support Utility Version
More informationVeritas NetBackup for Microsoft SQL Server Administrator's Guide
Veritas NetBackup for Microsoft SQL Server Administrator's Guide for Windows Release 8.1.1 Veritas NetBackup for Microsoft SQL Server Administrator's Guide Last updated: 2018-04-10 Document version:netbackup
More informationHP StorageWorks Storage Mirroring user s guide Storage Mirroring Application Manager
HP StorageWorks Storage Mirroring user s guide Storage Mirroring Application Manager Part number: T2558-96046 Fifth edition: vember 2006 Legal and notice information Copyright 1999-2006 Hewlett-Packard
More informationHP Database and Middleware Automation
HP Database and Middleware Automation For Windows Software Version: 10.10 SQL Server Database Refresh User Guide Document Release Date: June 2013 Software Release Date: June 2013 Legal Notices Warranty
More informationHP StorageWorks. P4000 SAN Solution user guide
HP StorageWorks P4000 SAN Solution user guide This guide provides information for configuring and using the HP StorageWorks SAN Solution. It includes hardware configuration and information about designing
More informationHP BladeSystem Management Pack (v 1.x) for Microsoft System Center User Guide
HP BladeSystem Management Pack (v 1.x) for Microsoft System Center User Guide Abstract This guide provides information on using the HP BladeSystem Management Pack for System Center version 1.x to manage
More informationHPE BladeSystem c-class Virtual Connect Support Utility Version Release Notes
HPE BladeSystem c-class Virtual Connect Support Utility Version 1.12.0 Release Notes Abstract This document provides release information for the HPE BladeSystem c-class Virtual Connect Support Utility
More informationHP StorageWorks MSA/P2000 Family Disk Array Installation and Startup Service
HP StorageWorks MSA/P2000 Family Disk Array Installation and Startup Service HP Services Technical data The HP StorageWorks MSA/P2000 Family Disk Array Installation and Startup Service provides the necessary
More informationHPE RDX Utility Version 2.36 Release Notes
HPE RDX Utility Version 2.36 Release Notes (RDX Tools 1.59) Abstract RDX Utility 2.36 (RDX Tools 1.59) enhances RDX Utility reporting for cartridges with a capacity greater than 2TB and implements Hewlett
More informationGuest Management Software V2.0.2 Release Notes
Guest Management Software V2.0.2 Release Notes Abstract These release notes provide important release-related information for GMS (Guest Management Software) Version 2.0.2. GMS V2.0.2 is MSM software version
More informationHP Storage Management Pack for System Center User Guide
HP Storage Management Pack for System Center User Guide Abstract This guide provides information about HP Storage Management Pack for System Center Operations Manager. HP Part Number: 5697-3673 Published:
More informationXP7 Online Migration User Guide
XP7 Online Migration User Guide Abstract This guide explains how to perform an Online Migration. Part Number: 858752-002 Published: June 2016 Edition: 6 Copyright 2014, 2016 Hewlett Packard Enterprise
More informationHP Insight Control for Microsoft System Center Installation Guide
HP Insight Control for Microsoft System Center Installation Guide Abstract This guide describes installing HP Insight Control for Microsoft System Center. This guide is intended for use by system integrators
More informationSite Recovery Manager Administration. Site Recovery Manager 6.1
Site Recovery Manager 6.1 You can find the most up-to-date technical documentation on the VMware Web site at: https://docs.vmware.com/ The VMware Web site also provides the latest product updates. If you
More informationInstallation and Configuration Guide
v7.0 HP Intelligent Management Center SQL Server 2008 Installation and Configuration Guide Abstract This document describes the configuration during and after database installation when IMC is used together
More informationConfiguring ApplicationHA in VMware SRM 5.1 environment
Configuring ApplicationHA in VMware SRM 5.1 environment Windows Server 2003 and 2003 R2, Windows Server 2008 and 2008 R2 6.0 September 2013 Contents Chapter 1 About the ApplicationHA support for VMware
More informationDell Storage vsphere Web Client Plugin. Version 4.0 Administrator s Guide
Dell Storage vsphere Web Client Plugin Version 4.0 Administrator s Guide Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make better use of your computer. CAUTION:
More informationStandardize Microsoft SQL Server Cluster Provisioning Using HP DMA
Technical white paper Standardize Microsoft SQL Server Cluster Provisioning Using HP DMA HP Database and Middleware Automation version 10.30 Table of Contents Purpose 2 Prerequisites 4 Process Overview
More informationHPE StoreVirtual Storage Application Aware Snapshot Manager Deployment Guide
HPE StoreVirtual Storage Application Aware Snapshot Manager Deployment Guide Abstract This guide contains instructions for installing and deploying the StoreVirtual Application Aware Snapshot Manager to
More informationHP LeftHand P4500 and P GbE to 10GbE migration instructions
HP LeftHand P4500 and P4300 1GbE to 10GbE migration instructions Part number: AT022-96003 edition: August 2009 Legal and notice information Copyright 2009 Hewlett-Packard Development Company, L.P. Confidential
More informationHP Data Protector 6.20 Granular Recovery Extension User Guide for VMware vsphere
HP Data Protector 6.20 Granular Recovery Extension User Guide for VMware vsphere HP Part Number: N/A Published: December 2011 Edition: Fourth Copyright 2011 Hewlett-Packard Development Company, L.P. Confidential
More informationHP BladeSystem Matrix Compatibility Chart
HP BladeSystem Matrix Compatibility Chart For supported hardware and software, including BladeSystem Matrix firmware set 1.01 Part Number 512185-003 December 2009 (Third Edition) Copyright 2009 Hewlett-Packard
More informationHP AutoPass License Server
HP AutoPass License Server Software Version: 9.0 Windows, Linux and CentOS operating systems Support Matrix Document Release Date: October 2015 Software Release Date: October 2015 Page 2 of 10 Legal Notices
More informationHP StoreOnce Recovery Manager Central for VMware User Guide
HP StoreOnce Recovery Manager Central 1.2.0 for VMware User Guide Abstract The guide is intended for VMware and database administrators who are responsible for backing up databases. This guide provides
More informationXP7 High Availability User Guide
XP7 High Availability User Guide Abstract HPE XP7 High Availability helps you create and maintain a synchronous copy of critical data in a remote location. This document describes and provides instructions
More informationHP Management Integration Framework 1.7
HP Management Integration Framework 1.7 Administrator Guide Abstract This document describes the use of HP Management Integration Framework interfaces and is intended for administrators involved in the
More informationVeeam Backup & Replication. Version 9.0
Veeam Backup & Replication Version 9.0 May, 2016 2016 Veeam Software. All rights reserved. All trademarks are the property of their respective owners. No part of this publication may be reproduced, transmitted,
More informationHP StorageWorks Booting Windows Server 2003 for Itanium-based systems from a storage area network application notes
HP StorageWorks Booting Windows Server 2003 for Itanium-based systems from a storage area network application notes Part number: AA RV22F TE Sixth edition: August 2006 Legal and notice information Copyright
More informationHPE Data Replication Solution Service for HPE Business Copy for P9000 XP Disk Array Family
Data sheet HPE Data Replication Solution Service for HPE Business Copy for P9000 XP Disk Array Family HPE Lifecycle Event Services HPE Data Replication Solution Service provides implementation of the HPE
More informationHP Storage Mirroring Application Manager 4.1 for Exchange white paper
HP Storage Mirroring Application Manager 4.1 for Exchange white paper Introduction... 2 Product description... 2 Features... 2 Server auto-discovery... 2 (NEW) Cluster configuration support... 2 Integrated
More informationHPE StoreVirtual OS v13.5 Release Notes
HPE StoreVirtual OS v13.5 Release Notes Part Number: 865552-006 Published: May 2017 Edition: 2 Contents Release notes...4 Description... 4 Platforms supported for this release... 4 Update recommendation...4
More informationDisaster Recovery-to-the- Cloud Best Practices
Disaster Recovery-to-the- Cloud Best Practices HOW TO EFFECTIVELY CONFIGURE YOUR OWN SELF-MANAGED RECOVERY PLANS AND THE REPLICATION OF CRITICAL VMWARE VIRTUAL MACHINES FROM ON-PREMISES TO A CLOUD SERVICE
More informationHP Data Protector Integration with Autonomy IDOL Server
Technical white paper HP Data Protector Integration with Autonomy IDOL Server Introducing e-discovery for HP Data Protector environments Table of contents Summary 2 Introduction 2 Integration concepts
More informationHPE StoreEver MSL6480 Tape Library CLI Utility Version 1.0 User Guide
HPE StoreEver MSL6480 Tape Library CLI Utility Version 1.0 User Guide Abstract This document explains how to install and use the HPE StoreEver MSL6480 Tape Library CLI utility, which provides a non-graphical
More informationConfiguring Embedded LDAP Authentication
HP Restricted Configuring Embedded LDAP Authentication configure Configuring Embedded LDAP Authentication For HP product models: LaserJet 4345mfp, LaserJet 9040mfp, LaserJet 9050mfp, LaserJet 9500mfp,
More informationHPE Operations Bridge Reporter
HPE Operations Bridge Reporter Software Version: 10.21 Windows and Linux operating systems Disaster Recovery Guide Document Release Date: October 2017 Software Release Date: August 2017 Legal Notices Warranty
More informationEMC NetWorker Module for SnapImage Release 2.0 Microsoft Windows Version
EMC NetWorker Module for SnapImage Release 2.0 Microsoft Windows Version Installation and Administration Guide P/N 300-007-130 REV A01 EMC Corporation Corporate Headquarters: Hopkinton, MA 01748-9103 1-508-435-1000
More informationSQL Server Installation and Configuration Guide. Abstract
SQL Server 2008 Installation and Configuration Guide Abstract This document describes the configuration during and after database installation when IMC is used together with Microsoft SQL Server. The document
More informationHP VMware ESXi and vsphere 5.x and Updates Getting Started Guide
HP VMware ESXi and vsphere 5.x and Updates Getting Started Guide Abstract This guide is intended to provide setup information for HP VMware ESXi and vsphere. HP Part Number: 616896-409 Published: September
More informationHP Storage Provisioning Manager HP 3PAR StoreServ Peer Persistence
Technical white paper HP Storage Provisioning Manager HP 3PAR StoreServ Peer Persistence Handling HP 3PAR StoreServ Peer Persistence with HP Storage Provisioning Manager Click here to verify the latest
More informationHPE StoreVirtual OS Update Guide
HPE StoreVirtual OS Update Guide Abstract This guide is intended for system administrators who are responsible for updating to the latest versions of software for StoreVirtual storage. Part Number: 865551-002
More informationHPE Data Protector Software Version: Zero Downtime Backup Administrator's Guide
HPE Data Protector Software Version: 9.09 Zero Downtime Backup Administrator's Guide Document Release Date: March 2017 Software Release Date: March 2017 Legal Notices Warranty The only warranties for Hewlett
More informationInstallation Guide. OMi Management Pack for Microsoft Skype for Business Server. Software Version: 1.00
OMi Management Pack for Microsoft Skype for Business Server Software Version: 1.00 For Operations Manager i for Linux and Windows operating systems Installation Guide Document Release Date: July 2017 Software
More information